ATTACHMENT 13 - Plumbing.pdf

PDF 2 MB Posted

Attached to
Y1AZ--EHRM Infrastructure Upgrades Construction West Palm Beach Federal contract opportunity
Solicitation number
36C77623B0045
Issued by
Department of Veterans Affairs Technology Acquisition Center Austin

About this file

This solicitation is for construction services to upgrade electronic health record infrastructure at the Department of Veterans Affairs Medical Center in West Palm Beach, Florida. The solicitation seeks to modernize plumbing systems across multiple floors and areas of the facility, including replacing and installing new plumbing fixtures. Upgrades will be made to domestic water supply, sanitary waste, and vent piping. Bidders should reference the attached architectural and mechanical drawings which provide details on demolition, new construction requirements, and plumbing fixture schedules. The solicitation number is 36C77623B0045 and was issued by the Department of Veterans Affairs Technology Acquisition Center located in Austin, Texas. The response due date and anticipated award date are not specified.

View the file

Other files for this federal contract opportunity

Other files attached to Y1AZ--EHRM Infrastructure Upgrades Construction West Palm Beach, newest first.
File Type Posted
Updated Drawings for Clarifications.pdf PDF
36C77623B0045 0003.pdf PDF
Clarifications to Technical Questions 9-5-23.pdf PDF
Cart Lift Motor Photos.pdf PDF
Photos for Responses to Questions 124 and 127.pdf PDF
Technical Questions - FINAL - West Palm Beach 8-21-23.pdf PDF
36C77623B0045 0002.pdf PDF
Map of Wells Question 66.pdf PDF
ATTACHMENT 24 - Construction Wage Rates - Palm Beach 7-7-23.pdf PDF
36C77623B0045 0001.pdf PDF
Site Visit Sign-in Sheet - West Palm Beach 7-19-23.pdf PDF
ATTACHMENT 1 - Specifications.pdf PDF
ATTACHMENT 2 - General.pdf PDF
ATTACHMENT 8 - Civil 5 of 5.pdf PDF
ATTACHMENT 9 - Electrical.pdf PDF
ATTACHMENT 12 - Mechanical 2 of 2.pdf PDF
ATTACHMENT 20 - Telecom 5 of 6.pdf PDF
ATTACHMENT 3 - Architectural.pdf PDF
36C77623B0045 - 7-6-23.pdf PDF
ATTACHMENT 6 - Civil 3 of 5.pdf PDF
ATTACHMENT 11 - Mechanical 1 of 2.pdf PDF
ATTACHMENT 14 - Security.pdf PDF
ATTACHMENT 15 - Structural.pdf PDF
ATTACHMENT 17 - Telecom 2 of 6.pdf PDF
ATTACHMENT 21 - Telecom 6 of 6.pdf PDF
ATTACHMENT 25 - Contractor Safety - Environmental Form.docx DOCX document
ATTACHMENT 4 - Civil 1 of 5.pdf PDF
ATTACHMENT 5 - Civil 2 of 5.pdf PDF
ATTACHMENT 16 - Telecom 1 of 6.pdf PDF
ATTACHMENT 18 - Telecom 3 of 6.pdf PDF
ATTACHMENT 19 - Telecom 4 of 6.pdf PDF
ATTACHMENT 23 - Limitations on Subcontracting - Construction.docx DOCX document
ATTACHMENT 24 - Construction Wage Rates - Palm Beach 3-24-23.pdf PDF
ATTACHMENT 7 - Civil 4 of 5.pdf PDF
ATTACHMENT 10 - Fire Protection.pdf PDF
ATTACHMENT 22 - Contractor Core Work Hours.pdf PDF
ATTACHMENT 26 - Site Visit Instructions.pdf PDF
Show all 37

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

C8

C

B

A8

A6

A

19 19.6 19.8 20.8 21.2 22 23 24 25 26 27

ELEV. (FUTURE)-1

P-7-1

ELEV.-2

P-8-2

ELEV.-2

P-10-2

ELEV.-2

P-9-2

TELE ROOM

1C-124

HAC

1C-122

CORR.

1C-121

FPF ASSISTANT

1C-126

THCH OFFICE

1C-206

ROOM

1C-222B

OFFICE

1C-271

PSYCH. OFFICE

1C-273

M. TLT.

1C-121B

F. TLT.

1C-121A

OFFICE

1C-112

ELEC.

1C-109

OFFICE

1C-114

F. TLT

1C-107

OFFICE

1C-116

BEAUTY SHOP

1C-232

RECPT. CLERK

1C-251

OFFICE

1C-138

UPS ELEC. RM.

1C-136

TR

1C-140

F. TLT

1C-134

M. TLT

1C-132

OFFICE

1C-142

CUBICLES

1C-130

OFFICE

1C-135C

OFFICE

1C-135F

ELEC.

1C-133

CLOSET

1C-135

PSYCHIATRIST

1C-135G

SUPV. OFFICE

1C-135H

SACRIST

1E-115C

COMMUNITY CARE

OFFICE

1C-131

UPSTAIR

STAIR

H.A.C.

1C-139

CORR.

1C-C3

OFFICE

1C-135B

M. TLT

1C-105

CATHOLIC CHAPLAIN

1E-118

CHIEF CHAPLAIN

SERVICES

1E-117

CHAPLAIN

1E-119

CHAPLAIN

1E-117

PSYCHIATRIST

1C-135E

OFFICE

1C-135D

ULTRA SOUND

1C-203

EUCHARIST

1E-114

DISPLAY

1C-221A

VOCATIONAL

REHABILITATION

CORRIDOR

1C-111

ADMIN.

1C-111

CORR.

1C-C3

CHANCEL

1E-115A

SECRETARY

1C-102

CORRIDOR

1C-101

CORRIDOR

1E-113

VEST.

C1-103

DECEDENT AFFAIRS

PATIENT SVC.

1G-122

ALCOVE

CI-104

FOOD SERVICE AREA

1C-233

WAITING

1C-250 CORR.

1C-250VENDOR

1C-222

OFFICE

1C-113

OFFICE

1C-115

OFFICE

1C-116A

SEATING

1C-222A

OFFICE

1C-135A

CORR.

1C-C1

NURSE

1C-146

STAIR #9

STAIR

WAITING

1C-280

VENDING MACHINES

1C-221

CORRIDOR

1C-C1

NAVE

1E-115

CHAPLAIN

1E-116

PSYCH. OFFICE

1C-275

B01-P101F

B01-P101F

OFFICE

1C-144

C

TR

1C-140

CORR.

1C-C3

OFFICE

1C-144

2 (E)1/2" DHW

(E)1 1/2" V

(E)1/2" DCW

C

TR

1C-140

CORR.

1C-C3

OFFICE

1C-144

(E)1/2" DHW

(E)1 1/2" V

(E)1/2" DCW

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

102 3rd Avenue, NE PO Box 1629, Hickory, NC 28603 T: 828.315.9962 F: 828.315.9964 www.atriaxgroup.com

KEYPLAN

PLAN NORTH

AREA F

03/31/23

B

IM

/2

V

A W e s t

P a lm B e a c h

E H

R M

I n fr a s tr u c tu re U p g ra d e s D e s ig n /5

-7

.B

.M T

R

.r v t

/3

/2

:3

:3

A

M

B01-P101F

FIRST LEVEL FLOOR PLAN - AREA

F - PLUMBING

ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM)

INFRASTRUCTURE UPGRADES

WEST PALM BEACH, FL

548-22-700

B01

03/31/23 JWB NLC

1/16" = 1'-0"1

FIRST LEVEL FLOOR PLAN - AREA F - PLUMBING

5 5 10 15 20 25 30 35 40 45

1/16" = 1'-0"

FEETSCALE

SHEET NOTES:

1. REMOVE SINK. SINK SHALL BE RELOCATED TO OFFICE 1C-144.

2. RELOCATED SINK. RECONNECT TO EXISTING VENT, SANITARY, AND DOMESTIC WATER PIPING.

1. THE CONTRACTOR SHALL BE RESPONSIBLE TO DESIGN AND INSTALL A COMPLETE FIRE PROTECTION SYSTEM WITHIN THE PROJECT AREA. THIS INCLUDES, BUT IS NOT LIMITED TO, RELOCATING PIPING TO ACCOMMODATE NEW CONSTRUCTION REQUIREMENTS, REVISING SPRINKLER HEAD LAYOUTS, AND COMPLYING WITH NFPA-13

AND DIVISION 21 SPECIFICATION REQUIREMENTS.

2. THIS PROJECT AREA IS WITHIN AN EXISTING FACILITY CONNECTED TO CITY DOMESTIC COLD WATER AND IS

PROTECTED BY AN EXISTING REDUCED PRESSURE BACKFLOW PREVENTER.

3. THE EXISTING DOMESTIC HOT WATER SYSTEM IS CONNECTED TO WATER HEATERS HEATING THE WATER TO 140 DEGREES, IT IS ROUTED TO AN ASSE 1017 THERMOSTATIC MIXING VALVE, DELIVERING THE HOT WATER PROVIDED TO THE PROJECT AREA PLUMBING FIXTURES AT 110 DEGREES. THE EXISTING HOT WATER SYSTEM

HAS A RECIRCULATING SYSTEM WITH A CIRCULATING PUMP.

4. THIS IS AN EXISTING BUILDING WITH AN EXISTING DOMESTIC WATER SYSTEM THAT IS BEING MODIFIED TO REPLACE AND/OR INSTALL NEW PLUMBING FIXTURES. HOT AND COLD WATER DEMANDS HAVE BEEN CALCULATED TO VERIFY THE EXISTING SYSTEM AND WATER HEATER EQUIPMENT IS ADEQUATE TO MEET THE NEEDS OF THE PLUMBING FIXTURES. THE USE OF A DIVERSITY FACTOR FOR CAPACITY HAS BEEN INCLUDED

IN THE DOMESTIC WATER DESIGN.

5. SEE ARCHITECTURAL SERIES SHEETS FOR OCCUPANT LOAD FOR PLUMBING FIXTURES.

PLUMBING GENERAL NOTES:

1/4" = 1'-0"3

FIRST LEVEL FLOOR PLAN - TR 1C-140 - NEW - PLUMBING

1/4" = 1'-0"2

FIRST LEVEL FLOOR PLAN - TR 1C-140 - DEMO - PLUMBING

2 2 4 6 8 10

1/4" = 1'-0"

FEETSCALE

2 2 4 6 8 10

1/4" = 1'-0"

FEETSCALE

Revisions: Date:

J

H

G8

G

E

D

C8

C

H4

1 2 3 4 5 6 7 8 9 9.2 9.8

STAIRWELL

ENCLOSURE

STAIR

STAIR #4-1

STAIR-1

ROOM

2A-304

STORAGE ROOM

2A-305

HAC

2A-302

ROOM

2A-303

MECHANICAL

2A-306

STAFF TLT.

2A-323

MED RM.

2A-321A

STAFF

2A-325

SOILED UTILITY

2A-326

CLEAN UTILITY

2A-327

ELECT. ROOM

2A-328

O.R. NURSE

MANAGER

2A-332

TRASH

2A-330

RECOVERY ROOM

ISOLATION BDRM

2A-329A

ANTE ROOM

2A-329

GAS STORAGE

2A-334

STAIR 5

STAIR

ELECT.

2B-302B

TEL.

2B-302C

MECHANICAL

2A-304A

MALE TLT.

2B-200

STAIR #2-2

STAIR-2

OFFICE

2A-118

OFFICE

2A-114

OFFICE CLERICAL

2A-119

HAC

2A-234

EQUIPMENT AND

APPARATUS

STORAGE

2A-236

CYSTOSCOPY ROOM

2A-238

EXTERNAL

RADIOGRAPHIC

CONTROL

2A-238B

INSTRUMENT PREP.

AND STERILIZATION

2A-238A

CYSTOSCOPY ROOM

2A-242

IMPLANT STORAGE

ROOM

2A-212

FROZEN SECT LAB

2A-229

DICT. CUBIC.

2A-227B

PHYS/STAFF LOUNGE

2A-227

MED. ROOM

2A-225A

ANASTHESIA

2A-225

SOILED HOLDING

AREA

2A-223

ROOM

2A-221

O.R. #5

2A-211

O.R. #3

2A-207

O.R. #4

2A-209

TELEPHONE/SWITCH

GEAR

2A-310

O.R. #6

2A-213

MALE LOCKERS

2A-246

SUB STERILE ROOM

2A-213A

UB STERILE

2A-207A

CORRIDOR

2A-C4

CORRIDOR

2A-227A

FINE INSTRUMENT

PREP. AND STOR.

2A-210

FEMALE LOCKERS

2A-244

F. TOILET/SHOWERS

2A-244A

RECOVERY ROOM

2A-320

RECOV RM NURSE

STATION

2A-321

SOILED LINEN CHUTE

2B-302A

SOILED SERVICE

LOBBY

2B-302

PATIENT TOILET

2A-205

CORRIDOR

2A-C7

BREAK RM

2A-279

ANESTHESIA

2A-278

NURSES ST.

2A-280

PATIENT TLT

2A-276

CLEAN

2A-274

PATIENT TLT

2A-277

MED

2A-269

SOIL

2A-275

ROOM

2A-272

CORRIDOR-2

2A-C3-2

BLANKETS

2A-271

CORRIDOR

2A-C1

NOURISHMENT

2A-273

PATIENT TLT

2A-266

TR

2A-281

CORRIDOR-2

2A-C7-2

PRE-OP

2A-C6

ANTE RM

2A-282

CLINICAL

COORDINATOR

2A-116

ATRIUM

B01-P102A

B01-P102A

G.8

9.8

CONTROL

STATION/CRT

2A-258

CORRIDOR

2A-C4

1/2"

1/2"

1 1/2"

TR

2A-281

CONTROL

STATION/CRT

2A-258CORRIDOR

2A-C4

TR

2A-281

CONTROL

STATION/CRT

2A-258

CORRIDOR

2A-C4

1/2" DOMESTIC COLD WATER

1/2" DOMESTIC HOT WATER

1 1/2" VENT

2" SANITARY

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

102 3rd Avenue, NE PO Box 1629, Hickory, NC 28603 T: 828.315.9962 F: 828.315.9964 www.atriaxgroup.com

KEYPLAN

PLAN NORTH

AREA A

03/31/23

B

IM

/2

V

A W e s t

P a lm B e a c h

E H

R M

I n fr a s tr u c tu re U p g ra d e s D e s ig n /5

-7

.B

.M T

R

.r v t

/3

/2

:3

:3

A

M

B01-P102A

SECOND LEVEL FLOOR PLAN -

AREA A - PLUMBING

ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM)

INFRASTRUCTURE UPGRADES

WEST PALM BEACH, FL

548-22-700

B01

03/31/23 JWB NLC

1/16" = 1'-0"1

SECOND LEVEL FLOOR PLAN - AREA A - PLUMBING

1/4" = 1'-0"2

SECOND LEVEL FLOOR PLAN -ANESTH. - DEMOLITION - PLUMBING

1/4" = 1'-0"3

SECOND LEVEL FLOOR PLAN - TR 2A-281 - NEW - PLUMBING

SHEET NOTES:

1. REMOVE SINK AND ASSOCIATED PIPING. CAP AT NEAREST MAIN.

2. CAP VENT AND DOMESTIC WATER PIPING AT MAIN IN INTERSTITIAL SPACE ABOVE ASSOCIATED FLOOR.

3. CAP SANITARY PIPING AT MAIN IN INTERSTITIAL SPACE BELOW ASSOCIATED FLOOR.

1. THE CONTRACTOR SHALL BE RESPONSIBLE TO DESIGN AND INSTALL A COMPLETE FIRE PROTECTION SYSTEM WITHIN THE PROJECT AREA. THIS INCLUDES, BUT IS NOT LIMITED TO, RELOCATING PIPING TO ACCOMMODATE NEW CONSTRUCTION REQUIREMENTS, REVISING SPRINKLER HEAD LAYOUTS, AND COMPLYING WITH NFPA-13

AND DIVISION 21 SPECIFICATION REQUIREMENTS.

2. THIS PROJECT AREA IS WITHIN AN EXISTING FACILITY CONNECTED TO CITY DOMESTIC COLD WATER AND IS

PROTECTED BY AN EXISTING REDUCED PRESSURE BACKFLOW PREVENTER.

3. THE EXISTING DOMESTIC HOT WATER SYSTEM IS CONNECTED TO WATER HEATERS HEATING THE WATER TO 140 DEGREES, IT IS ROUTED TO AN ASSE 1017 THERMOSTATIC MIXING VALVE, DELIVERING THE HOT WATER PROVIDED TO THE PROJECT AREA PLUMBING FIXTURES AT 110 DEGREES. THE EXISTING HOT WATER SYSTEM

HAS A RECIRCULATING SYSTEM WITH A CIRCULATING PUMP.

4. THIS IS AN EXISTING BUILDING WITH AN EXISTING DOMESTIC WATER SYSTEM THAT IS BEING MODIFIED TO REPLACE AND/OR INSTALL NEW PLUMBING FIXTURES. HOT AND COLD WATER DEMANDS HAVE BEEN CALCULATED TO VERIFY THE EXISTING SYSTEM AND WATER HEATER EQUIPMENT IS ADEQUATE TO MEET THE NEEDS OF THE PLUMBING FIXTURES. THE USE OF A DIVERSITY FACTOR FOR CAPACITY HAS BEEN INCLUDED

IN THE DOMESTIC WATER DESIGN.

5. SEE ARCHITECTURAL SERIES SHEETS FOR OCCUPANT LOAD FOR PLUMBING FIXTURES.

PLUMBING GENERAL NOTES:

5 5 10 15 20 25 30 35 40 45

1/16" = 1'-0"

FEETSCALE

2 2 4 6 8 10

1/4" = 1'-0"

FEETSCALE

2 2 4 6 8 10

1/4" = 1'-0"

FEETSCALE

TYPICAL PLUMBING DEMOLITION ISOMETRIC

G8

G

E

D

C8

H4

4 5 6 7 8 9 9.2 9.8

STAIR #5-6

STAIR-6

STAIR #4-6

STAIR-6

STAFF TOILET

8A-356A

INFECTION DISEASES

8A-352

CLINICAL

PHARMACIST

8A-346

EXAM

8A-340

EXAM

8A-334

EXAM

8A-328

EXAM

8A-322

DISPOSAL CHUTE

8A-318

EXAM

8A-320

STORAGE

8A-316

BMS HAC

8A-312

BMS HAC

8A-314

ELECT.

8A-302B

TELE.

8A-302C

COUNSELING

8A-113

EXAM

8A-117

COUNSELING

8A-229

EXAM

8A-121

EXAM

8A-129

EXAM

8A-127

EXAM

8A-123

EXAM

8A-125

OFFICE

8A-131

EXAM

8A-133

EXAM

8A-139

EXAM

8A-141

EXAM

8A-135

EXAM

8A-137

OFFICE

8A-143

EXAM

8A-147

EXAM

8A-149

EEG

8A-155

EXAM

8A-151

EXAM

8A-153

CLOSET

8A-159

PATIENT TOILET

8A-161

CORRIDOR

8A-C1E

PROGRAM ASSISTANT

8A-163

ASSIST. CHIEF

MEDICINE SERVICES

8A-165

EXAM

8A-226

EXAM

8A-227

CLEAN UTILITY RM

8A-225

ELEC. CLOSET

8A-221

STORAGE

8A-220

SOILED UTILITY ROOM

8A-224

PATIENT TOILET

8A-219

PATIENT TOILET

8A-218

MEDICATION

8A-217

STAFF TOILET

8A-215

EXAM

8A-214

EXAM

8A-213

EXAM

8A-212

EXAM

8A-211

EXAM

8A-210

WORK RM

8A-207

PATIENT TOILET

8A-206

SOILED LINEN CHUTE

8A-302A

READING ROOM

8A-145

EXAM

8A-157

INFECTION

DISEASESRM

8A-354

INFECTION DISEASES

8A-344

EXAM

8A-332

EXAM

8A-330

EXAM ROOM

8A-228

EXAM

8A-326

RHEUMATOLOGY

8A-336

OFFICE

8A-329

OFFICE

8A-348

DOCTOR'S OFFICE

8A-350

RECEPTION

8A-208

ALCOVE

8A-209

SCALES

8A-216

CORRIDOR

8A-C1C

CORRIDOR

8A-C1D

CORRIDOR

8A-C2

CORRIDOR

8A-C1

CORRIDOR

8A-C1B

CORRIDOR

8A-C7B

CORRIDOR

8A-C7A

CORRIDOR

8A-C7

CORRIDOR

8A-C7C

STAFF LOUNGE

8A-356B

LOCKERS

8A-C7E

ALCOVE

8A-205

COMM CLOSET

8A-204

PATIENT TOILET

8A-203

WAITING

8A-202

SOILED SERVICE

LOBBY

8A-302

TR

8A-222

EXAM

8A-324

B01-P108A

B01-P108A

G.8

9.8

ALLERGY CLINIC

8A-223

1/2"

1/2"

1 1/2"

TR

8A-222

CORRIDOR

8A-C7

ELEC. CLOSET

8A-221

TR

8A-222

CORRIDOR

8A-C7

ELEC. CLOSET

8A-221

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

102 3rd Avenue, NE PO Box 1629, Hickory, NC 28603 T: 828.315.9962 F: 828.315.9964 www.atriaxgroup.com

KEYPLAN

PLAN NORTH

AREA A

03/31/23

B

IM

/2

V

A W e s t

P a lm B e a c h

E H

R M

I n fr a s tr u c tu re U p g ra d e s D e s ig n /5

-7

.B

.M T

R

.r v t

/3

/2

:3

:3

A

M

B01-P108A

EIGHTH LEVEL FLOOR PLAN -

AREA A - PLUMBING

ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM)

INFRASTRUCTURE UPGRADES

WEST PALM BEACH, FL

548-22-700

B01

03/31/23 JWB NLC

1/16" = 1'-0"1

EIGHTH LEVEL FLOOR PLAN - AREA A - PLUMBING

1/4" = 1'-0"2

EIGHTH LEVEL FLOOR PLAN - ALLERGY CLINIC - DEMOLITION - PLUMBING

1/4" = 1'-0"3

EIGHTH LEVEL FLOOR PLAN - TR 8A-222 - NEW - PLUMBING

SHEET NOTES:

1. REMOVE SINK AND ASSOCIATED PIPING. CAP AT NEAREST MAIN.

1. THE CONTRACTOR SHALL BE RESPONSIBLE TO DESIGN AND INSTALL A COMPLETE FIRE PROTECTION SYSTEM WITHIN THE PROJECT AREA. THIS INCLUDES, BUT IS NOT LIMITED TO, RELOCATING PIPING TO ACCOMMODATE NEW CONSTRUCTION REQUIREMENTS, REVISING SPRINKLER HEAD LAYOUTS, AND COMPLYING WITH NFPA-13

AND DIVISION 21 SPECIFICATION REQUIREMENTS.

2. THIS PROJECT AREA IS WITHIN AN EXISTING FACILITY CONNECTED TO CITY DOMESTIC COLD WATER AND IS

PROTECTED BY AN EXISTING REDUCED PRESSURE BACKFLOW PREVENTER.

3. THE EXISTING DOMESTIC HOT WATER SYSTEM IS CONNECTED TO WATER HEATERS HEATING THE WATER TO 140 DEGREES, IT IS ROUTED TO AN ASSE 1017 THERMOSTATIC MIXING VALVE, DELIVERING THE HOT WATER PROVIDED TO THE PROJECT AREA PLUMBING FIXTURES AT 110 DEGREES. THE EXISTING HOT WATER SYSTEM

HAS A RECIRCULATING SYSTEM WITH A CIRCULATING PUMP.

4. THIS IS AN EXISTING BUILDING WITH AN EXISTING DOMESTIC WATER SYSTEM THAT IS BEING MODIFIED TO REPLACE AND/OR INSTALL NEW PLUMBING FIXTURES. HOT AND COLD WATER DEMANDS HAVE BEEN CALCULATED TO VERIFY THE EXISTING SYSTEM AND WATER HEATER EQUIPMENT IS ADEQUATE TO MEET THE NEEDS OF THE PLUMBING FIXTURES. THE USE OF A DIVERSITY FACTOR FOR CAPACITY HAS BEEN INCLUDED

IN THE DOMESTIC WATER DESIGN.

5. SEE ARCHITECTURAL SERIES SHEETS FOR OCCUPANT LOAD FOR PLUMBING FIXTURES.

PLUMBING GENERAL NOTES:

5 5 10 15 20 25 30 35 40 45

1/16" = 1'-0"

FEETSCALE

2 2 4 6 8 10

1/4" = 1'-0"

FEETSCALE

2 2 4 6 8 10

1/4" = 1'-0"

G8

G

E

D

C8

C

H4

9.8 10.4 11.2 11.812.2 13 14 15 16 17 1818.2

ELEV.-8

P-1-8

ELEV.-4

P-7-4

STAIR #1-7

STAIR-7

ELEV.-9

S-4-9

ELEV.-9

S-2-9

ELEV.-9

S-1-9

ELECT.

8A-302B

TELE.

8A-302C

LIFT 1

LIFT

PATIENT SERVICE

LOBBY

8B-306

BLIND REHAP ROOM

8B-314

LOW VISION COORD.

8B-316

EYE LANE

8B-320

EYE LANE

8B-322

EYE LANE

8B-328

EYE LANE

8B-334

EYE LANE

8B-332

EYE LANE

8B-340

EYE LANE

8B-346

EYE LANE

8B-344

TOILET

8B-350

TOILET

8B-352A

STAFF LOUNGE

8B-352

STAIR #6-8

STAIR-8

EYE LANE

8B-153

EYE LANE

8B-151

EYE LANE

8B-147

EYE LANE

8B-149

EYE LANE

8B-141

EYE LANE

8B-139

EYE LANE

8B-137

EYE LANE

8B-135

EYE LANE

8B-129

EYE LANE

8B-127

PA EXAM

ROOM/OFFICE

8B-157

MD/OD OFFICE

8B-155

MD/OD OFFICE

8B-145

MD/OD OFFICE

8B-133

MD/OD OFFICE

8B-143

MD/OD OFFICE

8B-131

PROVIDER OFFICE

8B-125

EXAM ROOM

8B-119

EXAM ROOM

8B-117

EXAM ROOM

8B-121

EXAM ROOM

8B-123

EXAM ROOM

8B-109

EXAM ROOM

8B-111

EXAM ROOM

8B-103

PROVIDER OFFICE

8B-115

PROVIDER OFFICE

8B-113

CORR.

8B-201

EYE LANE

8B-221

EYE LANE

8B-222

EYE LANE

8B-224

STORAGE ROOM

8B-220

TECH EYE LANE

8B-213

TECH EYE LANE

8B-215

VISUAL FIELD

8B-233

IOL MASTER/A SCAN

ROOM

8B-235

PROCEDURE ROOM

8B-246

SURGICAL NURSE

OFFICE

8B-242

LASER ROOM

8B-248

ADMINISTRATION

STATION

8B-231

EXAM ROOM-1

8B-216-1

EXAM ROOM

8B-212

EYE

CONFERENCE/TEACHING

ROOM

8B-230

ELEV.-9

S-5-9 EYE LANE-1

8B-330-1

EYE LANE

8B-342

ELEV.-9

S-3-9

HAC

8B-312

EYE LANE

8B-326

MD/OD OFFICE

8B-348

MD/OD OFFICE

8B-338

MALE TLT.

8B-200

PUBLIC TOILET

8B-204

PUBLIC TOILET

8B-206

UNISEX RESTROOM

8B-234

UNISEX RESTROOM

8B-236

ELEC. CLOSET

8B-247

PHOTOGRAPHY/TOMOGRAPHY

ROOM

8B-241

CORR.

8B-C7A

DILATION WAITING

AREA

8B-238

CORR.

8B-C7B

CORR.

8B-C7C

CORR.

8B-C1E

CORRIDOR

8B-C6

CORR.

8B-C1C

CORR.

8B-C4

CORR.

8B-C3

CORR.

8B-317

CORR.

8B-C1B

CORR.

8B-C1A

CORR.

8B-C1D

EYE LANE

8B-324

PROCEDURE ROOM

8B-232

EYE CLINIC PATIENT

WAITING

8B-210

FEMALE TLT.

8B-202

SOILED SERVICE

LOBBY

8A-302

UPS ELEC. RM.

8B-304B

EYE CLINIC CHECK-IN

DESK

8B-208

CORR.

8B-C1

MD/OD OFFICE

8B-336

EXAM ROOM

8B-214

B01-P108C

B01-P108C

G.8

9.8

1/2"

1/2" 1 1/2"

1/2"

1/2" 1 1/2"

TR

8B-245

CORRIDOR

8B-C6

TR

8B-245

CORRIDOR

8B-C6

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

102 3rd Avenue, NE PO Box 1629, Hickory, NC 28603 T: 828.315.9962 F: 828.315.9964 www.atriaxgroup.com

KEYPLAN

PLAN NORTH

AREA C

03/31/23

B

IM

/2

V

A W e s t

P a lm B e a c h

E H

R M

I n fr a s tr u c tu re U p g ra d e s D e s ig n /5

-7

.B

.M T

R

.r v t

/3

/2

:3

:4

A

M

B01-P108C

EIGHTH LEVEL FLOOR PLAN -

AREA C - PLUMBING

ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM)

INFRASTRUCTURE UPGRADES

WEST PALM BEACH, FL

548-22-700

B01

03/31/23 JWB NLC

1/16" = 1'-0"1

EIGHTH LEVEL FLOOR PLAN - AREA C - PLUMBING

1/4" = 1'-0"2

EIGHTH LEVEL FLOOR PLAN - OCT SCANNER/HRT - DEMOLITION - PLUMBING

1/4" = 1'-0"3

EIGHTH LEVEL FLOOR PLAN - TR 8B-245 - NEW - PLUMBING

SHEET NOTES:

1. REMOVE SINK AND ASSOCIATED PIPING. CAP AT NEAREST MAIN.

1. THE CONTRACTOR SHALL BE RESPONSIBLE TO DESIGN AND INSTALL A COMPLETE FIRE PROTECTION SYSTEM WITHIN THE PROJECT AREA. THIS INCLUDES, BUT IS NOT LIMITED TO, RELOCATING PIPING TO ACCOMMODATE NEW CONSTRUCTION REQUIREMENTS, REVISING SPRINKLER HEAD LAYOUTS, AND COMPLYING WITH NFPA-13

AND DIVISION 21 SPECIFICATION REQUIREMENTS.

2. THIS PROJECT AREA IS WITHIN AN EXISTING FACILITY CONNECTED TO CITY DOMESTIC COLD WATER AND IS

PROTECTED BY AN EXISTING REDUCED PRESSURE BACKFLOW PREVENTER.

3. THE EXISTING DOMESTIC HOT WATER SYSTEM IS CONNECTED TO WATER HEATERS HEATING THE WATER TO 140 DEGREES, IT IS ROUTED TO AN ASSE 1017 THERMOSTATIC MIXING VALVE, DELIVERING THE HOT WATER PROVIDED TO THE PROJECT AREA PLUMBING FIXTURES AT 110 DEGREES. THE EXISTING HOT WATER SYSTEM

HAS A RECIRCULATING SYSTEM WITH A CIRCULATING PUMP.

4. THIS IS AN EXISTING BUILDING WITH AN EXISTING DOMESTIC WATER SYSTEM THAT IS BEING MODIFIED TO REPLACE AND/OR INSTALL NEW PLUMBING FIXTURES. HOT AND COLD WATER DEMANDS HAVE BEEN CALCULATED TO VERIFY THE EXISTING SYSTEM AND WATER HEATER EQUIPMENT IS ADEQUATE TO MEET THE NEEDS OF THE PLUMBING FIXTURES. THE USE OF A DIVERSITY FACTOR FOR CAPACITY HAS BEEN INCLUDED

IN THE DOMESTIC WATER DESIGN.

5. SEE ARCHITECTURAL SERIES SHEETS FOR OCCUPANT LOAD FOR PLUMBING FIXTURES.

PLUMBING GENERAL NOTES:

5 5 10 15 20 25 30 35 40 45

1/16" = 1'-0"

FEETSCALE

2 2 4 6 8 10

1/4" = 1'-0"

FEETSCALE

2 2 4 6 8 10

1/4" = 1'-0"

G8

G

E

D

C8

H4

4 5 6 7 8 9 9.2 9.8

EXAM

9A-149

ASSOC. CHIEF

9A-151

EXAM

9A-147

OFFICE

9A-153

CORRIDOR

9A-C1F

OFFICE

9A-119

OFFICE

9A-111

EXAM

9A-113EXAM

9A-117

EXAM

9A-115

OFFICE

9A-121

CHIEF PRIMARY CARE

9A-155

OFFICE

9A-145

OFFICE

9A-143

EXAM

9A-139

EXAM

9A-137

EXAM

9A-135

OFFICE

9A-133

OFFICE

9A-131

OFFICE

9A-213

CLOSET

9A-208A

CLOSET

9A-211A

OFFICE

9A-214

OFFICE

9A-208

NUTRITIONIST

9A-209

MEDICATION

9A-221

OFFICE

9A-215

OFFICE

9A-216

OFFICE

9A-217

ELECT.

9A-227

OFFICE

9A-229OFFICE

9A-231

EXAM

9A-233

MEN TOILET

9A-223

WOMEN TOILET

9A-222

PATIENT TOILET

9A-220B

SUPPLIES

9A-224

PATIENT TOILET

9A-220A

SOILED TOILET

9A-226

EXAM

9A-330

EXAM

9A-328

EXAM

9A-334

EXAM

9A-346

EXAM

9A-340

EXAM

9A-344

EXAM

9A-342

STAIR #5-7

STAIR-7PACT SOCIAL

WORKER

9A-314

SUPPLY

9A-316

TELCOM.

9A-204

PATIENT TOILET

9A-203

EXISTING SOILED

SERVICE LOBBY

9B-302

EXISTING SOILED

LINEN CHUTE

9B-302A

TEL.

9B-302C

ELECTRICAL

9B-302B

EXAM

9A-127

EXAM

9A-129

EXAM

9A-125

EXAM

9A-123

OFFICE

9A-161

STAFF TOILET

9A-356A

EXAM

9A-352

EXAM

9A-354

STAFF LOCKERS

9A-356

ALCOVE

9A-212

OFFICE

9A-228

PATIENT TOILET

9A-206

EXAM

9A-322

EXAM

9A-320

EMS

9A-318

ROOM

9A-C7B

STAIR #4-7

STAIR-7

EXAM

9A-141

STORAGE / SUPPLY

9A-312

EXAM

9A-324

DIETICIAN

9A-207

OFFICE

9A-336

OFFICE

9A-326

OFFICE

9A-348

OFFICE

9A-338STAFF LOUNGE /

BREAK

9A-356B

OFFICE

9A-350

MECHANICAL

9A-304A

OFFICE

9A-163

ADMIN. OFFICE

9A-165

EKG

9A-220

CORRIDOR

9A-C1C

VITALS

9A-219

CORR.

9A-C2

ROOM

9A-C7A

OFFICE

9A-211

RECEPTION

9A-210

EQUIP. ALCOVE

9A-205

CORRIDOR

9A-C1D

CORRIDOR

9A-C1E

CORR.-1

9A-C1-1

ALCOVE

9A-234

WAITING

9A-202

ROOM

9A-C7C

CORRIDOR

9A-C7

B01-P109A

B01-P109A

1/2"

1/2" 1 1/2"

TR

9A-225

CORRIDOR

9A-C7

TR

9A-225

CORRIDOR

9A-C7

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

102 3rd Avenue, NE PO Box 1629, Hickory, NC 28603 T: 828.315.9962 F: 828.315.9964 www.atriaxgroup.com

KEYPLAN

PLAN NORTH

AREA A

03/31/23

B

IM

/2

V

A W e s t

P a lm B e a c h

E H

R M

I n fr a s tr u c tu re U p g ra d e s D e s ig n /5

-7

.B

.M T

R

.r v t

/3

/2

:3

:4

A

M

B01-P109A

NINTH LEVEL FLOOR PLAN - AREA

A - PLUMBING

ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM)

INFRASTRUCTURE UPGRADES

WEST PALM BEACH, FL

548-22-700

B01

03/31/23 JWB NLC

1/16" = 1'-0"1

NINTH LEVEL FLOOR PLAN - AREA A - PLUMBING

1/4" = 1'-0"2

NINTH LEVEL FLOOR PLAN - OFFICE - DEMOLITION - PLUMBING

1/4" = 1'-0"3

NINTH LEVEL FLOOR PLAN - TR 9A-225 - NEW - PLUMBING

SHEET NOTES:

1. REMOVE SINK AND ASSOCIATED PIPING. CAP AT NEAREST MAIN.

1. THE CONTRACTOR SHALL BE RESPONSIBLE TO DESIGN AND INSTALL A COMPLETE FIRE PROTECTION SYSTEM WITHIN THE PROJECT AREA. THIS INCLUDES, BUT IS NOT LIMITED TO, RELOCATING PIPING TO ACCOMMODATE NEW CONSTRUCTION REQUIREMENTS, REVISING SPRINKLER HEAD LAYOUTS, AND COMPLYING WITH NFPA-13

AND DIVISION 21 SPECIFICATION REQUIREMENTS.

2. THIS PROJECT AREA IS WITHIN AN EXISTING FACILITY CONNECTED TO CITY DOMESTIC COLD WATER AND IS

PROTECTED BY AN EXISTING REDUCED PRESSURE BACKFLOW PREVENTER.

3. THE EXISTING DOMESTIC HOT WATER SYSTEM IS CONNECTED TO WATER HEATERS HEATING THE WATER TO 140 DEGREES, IT IS ROUTED TO AN ASSE 1017 THERMOSTATIC MIXING VALVE, DELIVERING THE HOT WATER PROVIDED TO THE PROJECT AREA PLUMBING FIXTURES AT 110 DEGREES. THE EXISTING HOT WATER SYSTEM

HAS A RECIRCULATING SYSTEM WITH A CIRCULATING PUMP.

4. THIS IS AN EXISTING BUILDING WITH AN EXISTING DOMESTIC WATER SYSTEM THAT IS BEING MODIFIED TO REPLACE AND/OR INSTALL NEW PLUMBING FIXTURES. HOT AND COLD WATER DEMANDS HAVE BEEN CALCULATED TO VERIFY THE EXISTING SYSTEM AND WATER HEATER EQUIPMENT IS ADEQUATE TO MEET THE NEEDS OF THE PLUMBING FIXTURES. THE USE OF A DIVERSITY FACTOR FOR CAPACITY HAS BEEN INCLUDED

IN THE DOMESTIC WATER DESIGN.

5. SEE ARCHITECTURAL SERIES SHEETS FOR OCCUPANT LOAD FOR PLUMBING FIXTURES.

PLUMBING GENERAL NOTES:

5 5 10 15 20 25 30 35 40 45

1/16" = 1'-0"

FEETSCALE

2 2 4 6 8 10

1/4" = 1'-0"

FEETSCALE

2 2 4 6 8 10

1/4" = 1'-0"

G8

G

E

D

C8

C

H4

9.8 10.4 11.2 11.812.2 13 14 15 16 17 1818.2

EXISTING ELEV.

P-1

STAIR #1-8

STAIR-8

ELEV.-10

S-5-10

ELEV.-10

S-4-10

EXISTING ELEV.

S-2

EXISTING ELEV.

S-1

STORAGE

9B-304B

EXISTING ELEV.

S-3

UNISEX TOILET

9B-200

MALE H.C. TOILET

9B-204

FEMALE H.C. TOILET

9B-206

OFFICE

9B-103

OFFICE

9B-159

NURSE MANAGER

9B-165

EQUIP. ROOM

9B-163

PRIMARY CARE

9B-155

EXAM

9B-125

PACT SOCIAL

WORKER

9B-123

EXAM

9B-129

EXAM

9B-127

OFFICE

9B-121EXAM

9B-117

EXAM

9B-115

E.K.G. ROOM

9B-113

EXAM

9B-111

OFFICE

9B-119

EXAM

9B-219

CLOSET

9B-210A

OFFICE

9B-210

STORAGE

9B-212A

EXAM

9B-216

EXAM

9B-215

MEDICATION

9B-223

EXAM

9B-218

EXAM

9B-217

PATIENT TOILET

9B-225

PATIENT TOILET

9B-224

SUPPLIES

9B-226

PATIENT TOILET

9B-222B

PATIENT TOILET

9B-222A

ELECT.

9B-229

OFFICE

9B-231

OFFICE

9B-233

EXAM

9B-235

EXAM

9B-141

OFFICE

9B-143

EXAM

9B-139

EXAM

9B-135

EXAM

9B-137

OFFICE

9B-133

OFFICE

9B-131

SOILED UTILITY

9B-228

OFFICE

9B-230

EXAM

9B-149

EXAM

9B-147

PRIMARY CARE EXAM

9B-153

EXAM ROOM

9B-151

SOCIAL WORKER

9B-209

PATIENT TOILET

9B-208

STAFF TOILET

9B-220

TELCOM.

9B-205

PATIENT TOILET

9B-203

OFFICE

9B-348

OFFICE

9B-338

OFFICE

9B-336

OFFICE

9B-326

EXAM

9B-328

EXAM

9B-330

EXAM

9B-332

EXAM

9B-334

EXAM

9B-340

EXAM

9B-342

EXAM

9B-344

EXAM

9B-346

EXAM

9B-354

EXAM

9B-352

OFFICE

9B-350

STAFF TOILET

9B-356A

STORAGE SUPPLY

9B-312

OFFICE

PSYCHOLOGIST

STORAGE

9B-314

EXISTING SOILED

SERVICE LOBBY

9B-302

TEL.

9B-302C

ELECTRICAL

9B-302B

ELEVATOR SERVICE

LOBBY

9B-306

CORRIDOR-1

9B-C7-1

NUTRITIONIST

9B-213

EXISTING HAC

9B-316

EXAM

9B-320

EXAM

9B-322

PRIMARY CARE EXAM

9B-157

OFFICE

9B-212

ALCOVE

9B-214

OFFICE

9B-105

OFFICE

9B-324

EXAM

9B-145

OFFICE

9B-109

UNISEX TOILET

9B-202

MECHANICAL

9B-304A

CORR.

9B-C7A

CORR.

9B-C7B

CORR.

9B-C7C

STAIR #6-9

STAIR-9

STAFF LOUNGE /

BREAK

9B-356B

STAFF LOCKERS

9B-356

OFFICE

9B-161

CORRIDOR

9B-C1E

CORRIDOR

9B-C1D

CORRIDOR

9B-C1C

CORRIDOR

9B-C1B

CORRIDOR

9B-C1A

VITAL SIGNS STATION

9B-221

CORR.

9B-C2

ALCOVE

9B-236

CORRIDOR

9B-C7

EQUIP. ALCOVE

9B-207

RECEPTION

9B-211

WAITING

9B-201

PROCEDURE ROOM

9B-222

EXISTING CORRIDOR

9B-C1

B01-P109C

B01-P109C

11/2"

1/2" 1 1/2"

TR

9B-227

CORRIDOR

9B-C714

TR

9B-227

CORRIDOR

9B-C7

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

102 3rd Avenue, NE PO Box 1629, Hickory, NC 28603 T: 828.315.9962 F: 828.315.9964 www.atriaxgroup.com

KEYPLAN

PLAN NORTH

AREA C

03/31/23

B

IM

/2

V

A W e s t

P a lm B e a c h

E H

R M

I n fr a s tr u c tu re U p g ra d e s D e s ig n /5

-7

.B

.M T

R

.r v t

/3

/2

:3

:5

A

M

B01-P109C

NINTH LEVEL FLOOR PLAN - AREA

C - PLUMBING

ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM)

INFRASTRUCTURE UPGRADES

WEST PALM BEACH, FL

548-22-700

B01

03/31/23 JWB NLC

1/16" = 1'-0"1

NINTH LEVEL FLOOR PLAN - AREA C - PLUMBING

1/4" = 1'-0"2

NINTH LEVEL FLOOR PLAN - PCSH INTERN - DEMOLITION - PLUMBING

1/4" = 1'-0"3

NINTH LEVEL FLOOR PLAN - TR 9B-227 - NEW - PLUMBING

SHEET NOTES:

1. REMOVE SINK AND ASSOCIATED PIPING. CAP AT NEAREST MAIN.

1. THE CONTRACTOR SHALL BE RESPONSIBLE TO DESIGN AND INSTALL A COMPLETE FIRE PROTECTION SYSTEM WITHIN THE PROJECT AREA. THIS INCLUDES, BUT IS NOT LIMITED TO, RELOCATING PIPING TO ACCOMMODATE NEW CONSTRUCTION REQUIREMENTS, REVISING SPRINKLER HEAD LAYOUTS, AND COMPLYING WITH NFPA-13

AND DIVISION 21 SPECIFICATION REQUIREMENTS.

2. THIS PROJECT AREA IS WITHIN AN EXISTING FACILITY CONNECTED TO CITY DOMESTIC COLD WATER AND IS

PROTECTED BY AN EXISTING REDUCED PRESSURE BACKFLOW PREVENTER.

3. THE EXISTING DOMESTIC HOT WATER SYSTEM IS CONNECTED TO WATER HEATERS HEATING THE WATER TO 140 DEGREES, IT IS ROUTED TO AN ASSE 1017 THERMOSTATIC MIXING VALVE, DELIVERING THE HOT WATER PROVIDED TO THE PROJECT AREA PLUMBING FIXTURES AT 110 DEGREES. THE EXISTING HOT WATER SYSTEM

HAS A RECIRCULATING SYSTEM WITH A CIRCULATING PUMP.

4. THIS IS AN EXISTING BUILDING WITH AN EXISTING DOMESTIC WATER SYSTEM THAT IS BEING MODIFIED TO REPLACE AND/OR INSTALL NEW PLUMBING FIXTURES. HOT AND COLD WATER DEMANDS HAVE BEEN CALCULATED TO VERIFY THE EXISTING SYSTEM AND WATER HEATER EQUIPMENT IS ADEQUATE TO MEET THE NEEDS OF THE PLUMBING FIXTURES. THE USE OF A DIVERSITY FACTOR FOR CAPACITY HAS BEEN INCLUDED

IN THE DOMESTIC WATER DESIGN.

5. SEE ARCHITECTURAL SERIES SHEETS FOR OCCUPANT LOAD FOR PLUMBING FIXTURES.

PLUMBING GENERAL NOTES:

5 5 10 15 20 25 30 35 40 45

1/16" = 1'-0"

FEETSCALE

2 2 4 6 8 10

1/4" = 1'-0"

FEETSCALE

2 2 4 6 8 10

1/4" = 1'-0"

BFP

BFP

A

1 1

L

WC

MS

S

4" SAN

FS 1 1/2" DCW UP

1 1/2" V UP

1 1/2" V UP

1 1/2" UP

1 1/2" UP

2" SAN

4"

A B

1 1

2 2

UH-1

AC-2

AC-1

P-801

3/4" DCW

3/4" DCW

3/4" DCW

B23-P101

P-801

CORR 1

C-100

SERVER ROOM

CORR 3

C-102

GENERATORS

EMERGENCY ELECT.

ENTRANCE RM 2

CORR 4

C-103

ELECT.

OFFICE/EQUIPMENT STAGING

ENTRANCE RM 1

CORR 2

C-101

SPRLKR. RISER

110 STORAGE

AC-3

REMARKS:

1. REFER TO ARCHITECTURAL PLANS AND ELEVATIONS FOR ADDITIONAL REQUIREMENTS, ROUGH IN DIMENSIONS, AND COORDINATION OF ACCESSORIES. FIXTURE MOUNTING

LOCATIONS AND OPERATION OF FIXTURE SHALL NOT INTERFERE WITH ADJACENT ACCESSORIES OR THEIR OPERATION.

2. CONTRACTOR SHALL COORDINATE ALL FIXTURES WITH OTHER TRADES. ANY CONFLICTS OR ADJUSTMENTS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ENGINEER.

3. COORDINATE SINK BASINS AND DRAIN OUTLETS WITH CASEWORK AND KNEE GUARDS. PROVIDE OFFSET TAILPIECES AS REQUIRED TO ACCOMMODATE INSTALLATION AND COMPLY

WITH ADA REQUIREMENTS.

4. COORDINATE FLUSH VALVE INSTALLATION WITH GRAB BARS IN ALL LOCATIONS.

5. COORDINATE MOUNTING OF FAUCET SPOUTS WITH BASINS. FAUCET SHALL NOT DISCHARGE DIRECTLY INTO BASIN DRAIN AND SHALL PROVIDE SUFFICIENT CLEARANCE BETWEEN

STREAM AND BASIN TO ALLOW FOR UNOBSTRUCTED HAND WASHING WITHOUT CONTACT WITH THE BASIN. CONTRACTOR SHALL OBTAIN AND COORDINATE WITH SHOP DRAWINGS

FROM COUNTER AND CASEWORK MANUFACTURERS.

6. COORDINATE DRAIN GRATE WITH FLOOR SLOPING AND FLOORING PATTERN FOR ALL FLOOR DRAINS, FLOOR SINKS, AND TRENCH DRAINS. DRAIN SHALL BE SET SUCH THAT DRAIN GRATE IS FLUSH WITH FINISHED FLOOR SURFACE AND COORDINATED WITH PATTERN. REFER TO ARCHITECTURAL PLANS AND DETAILS FOR ADDITIONAL INFORMATION.

A

2 2

1 1/4" DCW

1/2" DCW

FD-H

P-101

P-401

P-501

P-528

3/4" DHW

3/4" DCW WH-1

2" V

1" UP 3

1" DCW

1 1/2" DCW DN 1 1/2" DN

1 1/2" DN

3" VTR

EXPANSION TANK (SUPPORT

INDEPENDENTLY FROM STRUCTURE)

DRAIN VALVE

FLOOR DRAIN WITH

FUNNEL SPOUT (OR FLOOR

SINK, AS REQUIRED)

FINISHED FLOOR

SEE DRAWING

FOR CONTINUATION

AND PIPE SIZES

HOUSEKEEPING

PAD

ELECTRIC

WATER

HEATER

HOT WATER SUPPLY

COLD WATER SUPPLY

REMARKS:

1. PROVIDE WITH RELIEF VALVE, DIELECTRIC CONNECTIONS, THERMOMETERS ON INLET / OUTLET, AND EXPANSION TANK.

2. MOUNT ON 4" HOUSEKEEPING PAD.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

102 3rd Avenue, NE PO Box 1629, Hickory, NC 28603 T: 828.315.9962 F: 828.315.9964 www.atriaxgroup.com

03/31/23

B

IM

/2

V

A W e s t

P a lm B e a c h

E H

R M

I n fr a s tr u c tu re U p g ra d e s D e s ig n /5

-7

.B

.M T

R

.r v t

/3

/2

:1

:2

P

M

B23-P101

FLOOR PLANS - PLUMBING ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM)

INFRASTRUCTURE UPGRADES

WEST PALM BEACH, FL

548-22-700

B23

03/31/23 JWB NLC

PLAN NORTH

A. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.

B. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN DASHED, EXISTING

MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER PLANS, NEW

MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.

C. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL

PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.

D. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO

PERFORM THIS WORK.

GENERAL NOTES:

SHEET NOTES:

1. REFER TO CIVIL DRAWINGS FOR CONTINUATION.

2. MAINTAIN 10' SEPARATION BETWEEN VENT PENTRATION THROUGH ROOF AND OUTDOOR AIR INTAKE FOR

ROOFTOP UNIT.

3. ROUTE 1" DCW UP TO RH-1 ON ROOF. COORDINATE EXACT LOCATION OF ROOF HYDRANT WITH SCREEN WALL

AND ROOFTOP EQUIPMENT. PROVIDE DRAIN DOWN CONNECTION AND ROUTE TO MOP SINK.

1/4" = 1'-0"2

UNDERFLOOR LEVEL FLOOR PLAN - PLUMBING

5 5 10 15 20

1/8" = 1'-0"

FEETSCALE

1/8" = 1'-0"1

FIRST LEVEL FLOOR PLAN - PLUMBING

2 2 4 6 8 10

1/4" = 1'-0"

FEETSCALE

PLUMBING FIXTURE SCHEDULE

MARK TYPE DESCRIPTION

PIPING CONNECTIONS

COLD WATER HOT WATER WASTE VENT

FD-H FLOOR SINK REFER TO SPECIFICATION PER APPLICABLE

PLUMBING CODE

PER APPLICABLE

PLUMBING CODE

P-101 FLOOR MOUNTED

WATER CLOSET

REFER TO SPECIFICATION 1" - 4" 2"

P-401 LAVATORY REFER TO SPECIFICATION 1/2" 1/2" 2" 1 1/2"

P-501 MOP SINK REFER TO SPECIFICATION 3/4" 3/4" 3" 1 1/2"

P-528 SINK REFER TO SPECIFICATION 1/5" 1/2" 2" 1 1/2"

P-801 HOSE BIB REFER TO SPECIFICATION 3/4" - - -

RH-1 ROOF HYDRANT ROOF HYDRANT - FREEZELESS ROOF HYDRANT, SELF-DRAINING, DUAL

CHECK BACKFLOW PREVENTER INTEGRAL TO HYDRANT, 3/4" MALE HOSE

THREAD, GALVANIZED STEEL PIPE CASING. PROVIDE WITH CAST IRON

MOUNTING SYSTEM INCLUDING UNDERDECK FLANGE, EPDM COVER, AND

CAST IRON SUPPORT OF SUFFICIENT LENGTH TO CLEAR ROOF INSULATION

THICKNESS. ASSE 1052 LISTED AND APPROVED. WOODFORD MODEL

RHY2-MS OR APPROVED EQUAL.

1" - - -

1/4" = 1'-0"4

FIRST LEVEL FLOOR PLAN - PLUMBING ENLARGED

2 2 4 6 8 10

1/4" = 1'-0"

FEETSCALE

NO SCALE3

ELECTRIC WATER HEATER

ELECTRIC WATER HEATER SCHEDULE

MARK

STORAGE

CAPACITY

STORAGE WATER

TEMPERATURE

[°F]

RECOVERY

(@ 100°F RISE)

[GPH]

DISTRIBUTION

WATER

TEMPERATURE

[°F]

ELECTRICAL DATA

MANUFACTURER MODEL REMARKSKW FLA VOLTAGE PHASE DISCONNECT BY

WH-1 10 140 25 120 6 7.2 480 V 3 ELECTRICAL AO SMITH DSE-10A (1)(2)

B01-P101F - FIRST LEVEL FLOOR PLAN -AREA F -PLUMBING
B01-P102A - SECOND LEVEL FLOOR PLAN -AREA A -PLUMBING
B01-P108A - EIGHTH LEVEL FLOOR PLAN -AREA A -PLUMBING
B01-P108C - EIGHTH LEVEL FLOOR PLAN -AREA C -PLUMBING
B01-P109A - NINTH LEVEL FLOOR PLAN -AREA A -PLUMBING
B01-P109C - NINTH LEVEL FLOOR PLAN -AREA C -PLUMBING
B23-P101 - FLOOR PLANS -PLUMBING