This document provides construction drawings for fire protection systems for the Electronic Health Record Modernization (EHRM) Infrastructure Upgrades project at the Department of Veterans Affairs Medical Center in West Palm Beach, Florida. The drawings cover basement, first, second, third, fourth and fifth floor levels and include new and demolished layouts. Key areas covered include operating rooms, laboratories, radiology, ICU, mental health and orthopedics units. Systems shown include sprinklers, alarms, smoke dampers and medical gas manifolds. Construction will require coordination between mechanical, electrical and low voltage contractors.
View the file
Other files for this federal contract opportunity
Show all 37
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ABBREVIATION
GENERAL ABBREVIATIONS
DESCRIPTION ABBREVIATION DESCRIPTION
NOT ALL ABBREVIATIONS APPLY TO THIS SET OF DOCUMENTS
AD ACCESS DOOR/PANEL
AFF ABOVE FINISHED FLOOR
AMB AMBIENT
DIA DIAMETER
DN DOWN
E EXISTING
EC ELECTRICAL CONTRACTOR
EFF EFFICIENCY
GC GENERAL CONTRACTOR
FPM FEET PER MINUTE
FPS FEET PER SECOND
L LENGTH
LF LINEAR FEET
MAX MAXIMUM
MC MECHANICAL CONTRACTOR
MFR MANUFACTURER
MIN MINIMUM
NIC NOT IN CONTRACT
NTS NOT TO SCALE
PC PLUMBING CONTRACTOR
PSIG POUNDS PER SQUARE INCH GAUGE
RPM REVOLUTIONS PER MINUTE
SHT SHEET
TOB TOP OF BEAM
GPM GALLONS PER MINUTE
TOS TOP OF STEEL
BOB BOTTOM OF BEAM
VEL VELOCITY
VFD VARIABLE FREQUENCY DRIVE
UNION
Y STRAINER WITH BLOWDOWN
ELBOW UP
ELBOW DOWN
TEE UP
PIPING
- SOLID LINE INDICATES SYSTEM SUPPLY
-- DASHED LINE INDICATES SYSTEM RETURN
NUMBER INDICATES NOMINAL DIAMETER IN INCHES,
LETTER(S) INDICATES SYSTEM.
REFER TO ABBREVIATIONS FOR SYSTEM TYPE.
GENERAL MECHANICAL SYMBOLS
SYMBOL DESCRIPTION ADDITIONAL REMARKS
# SHEET NOTE
DENOTES SPECIFIC REQUIREMENT FOR THE SHEET ON WHICH THE NOTE APPEARS
AND IS USED TO DESCRIBE WORK THAT IS TOO LENGTHY TO PLACE ON PLAN.
DIAMETER
DENOTES CONNECTION OF NEW WORK TO
EXISTING SYSTEM
PROTECT EXISTING SYSTEM FROM ENTRANCE OF FOREIGN DEBRIS DURING WORK.
ARROW INDICATES DOWNWARD PIPE SLOPE
#/# INDICATES SLOPE IN INCHES PER FOOT
WHERE PIPING IS NOT MARKED, REFER TO SPECIFICATIONS FOR REQUIREMENTS
ARROW INDICATES DIRECTION OF FLOW IN PIPING
ISOLATION VALVE REFER TO SPECIFICATIONS FOR TYPE BASED ON SIZE AND SYSTEM
CHECK VALVE
ARROW INDICATES DIRECTION OF NORMAL FLOW
REFER TO SPECIFICATIONS FOR TYPE BASED ON SIZE AND SYSTEM
PIPE IN SLEEVE REFER TO SPECIFICATIONS FOR TYPE BASED ON SIZE AND SYSTEM
CIRCUIT SETTER, AUTOFLOW, ETC.
REFER TO SPECIFICATIONS FOR TYPE BASED ON SIZE AND SYSTEM
PRESSURE GAUGE
REFER TO SPECIFICATIONS FOR TYPE AND ACCESSORIES
REFER TO SPECIFICATIONS FOR TYPE AND ACCESSORIES
REFER TO SPECIFICATIONS FOR TYPE AND ACCESSORIESTHERMOMETER - HORIZONTAL PIPE
TEE DOWN
TEE HORIZONTAL
PIPE REDUCER
INDICATES POINT WHERE PIPING CHANGES FROM ONE SIZE TO ANOTHER.
SMALL POINT OF ARROW INDICATES SMALLER SIZE SIDE OF TRANSITION.
REQUIRED SERVICE CLEARANCE FOR EQUIPMENT
CONTINUATION
FIRST SYMBOL APPLIES TO ROUND DUCT AND PIPING.
SECOND SYMBOL APPLIES TO RECTANGULAR AND OVAL DUCT.
AIR VENT
AUTOMATIC FLOW CONTROL VALVE
# INDICATES FLOW TO BE BALANCED IN GPM
BACKFLOW PREVENTER
CALIBRATED BALANCING VALVE
VALVE - THROTTLING SERVICE
VALVE - SHUTOFF SERVICE
P/T PORT
PIPE CAP
PIPE CONTINUATION
PRESSURE GAUGE STEAM REFER TO SPECIFICATIONS FOR TYPE AND ACCESSORIES
PRESSURE REDUCING VALVE
PUMP
RELIEF VALVE
S SENSOR
SUCTION DIFFUSER
THERMOMETER - VERTICAL PIPE REFER TO SPECIFICATIONS FOR TYPE AND ACCESSORIES
VACUUM BREAKER
Y STRAINER
STEAM TRAP
CC CONTROLS CONTRACTOR
SYMBOL
FIRE PROTECTION SYMBOLS
DESCRIPTION ADDITIONAL REMARKS
FLOW SWITCH COORDINATE INTERFACE WITH FIRE ALARM SYSTEM CONTRACTOR
FIRE DEPARTMENT CONNECTION MOUNT BETWEEN 18" AND 48" ABOVE FINISHED GRADE
REFER TO SPECIFICATIONS FOR TYPES AND FINISHES.
PENDANT REFERS TO FULL, SEMI-RECESSED AND RECESSED TYPES. LOCATIONS
FOR EACH ARE INDICATED IN THE SPECIFICATIONS OR ON THE PLANS.
SIDEWALL SPRINKLER -
EXISTING SIDEWALL SPRINKLER
SPRINKLER
EXISTING SPRINKLER
EXISTING SPRINKLER TO BE REMOVED
FIRE PIPEF
O.S. & Y. VALVE
SHUT-OFF VALVE WITH TAMPER SWITCHTS
F
ABBREVIATION
FIRE PROTECTION ABBREVIATIONS
DESCRIPTION
BACK FLOW PREVENTERBFP
FIRE PROTECTIONF
FIRE DEPARTMENT CONNECTIONFDC
ABBREVIATION DESCRIPTION
FLOW SWITCHFS
POST INDICATOR VALVEPIV
SPRINKLERSPR
NOT ALL ABBREVIATIONS APPLY TO THIS SET OF DOCUMENTS
LEGEND: (LOW VOLTAGE COORDINATION LEGEND)
CF: CONTRACTOR FURNISHED
CI: CONTRACTOR INSTALLED
OF: OWNER FURNISHED
OI: OWNER INSTALLED
REMARKS: (LOW VOLTAGE COORDINATION LEGEND)
1. FIRE ALARM IS AN EXTENSION OF AN EXISTING SIEMENS, DESIGO SYSTEM. NEW DEVICES SHALL FUNCTION AS AN
EXTENSION OF THE EXISTING SYSTEM. EXISTING VENDOR CONTACT: SIEMENS MIAMI BRANCH (954) 364-6600.
CONSTRUCTION PROJECT CONTACT: DAVID METZGER (954) 292-4380.
GENERAL NOTES: (LOW VOLTAGE COORDINATION LEGEND)
A. REFER TO SYMBOL LEGENDS AND SPECIFICATIONS FOR SPECIFIC REQUIREMENTS.
B. COORDINATE ROUGH-IN REQUIREMENTS WITH FINAL EQUIPMENT SELECTION FOR ALL SYSTEMS.
C. COORDINATE ROUGH-IN REQUIREMENTS WITH OWNER FOR OWNER FURNISHED SYSTEMS.
D. CONDUITS SHALL ROUTE CONCEALED INSIDE WALL TO ABOVE NEAREST ACCESSIBLE CEILING SPACE, UNLESS
OTHERWISE INDICATED.
E. WHERE CABLING IS CONTRACTOR FURNISHED AND CONTRACTOR INSTALLED, TERMINATE AND TEST ALL CABLING PER
SPECIFICATION.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
102 3rd Avenue, NE PO Box 1629, Hickory, NC 28603 T: 828.315.9962 F: 828.315.9964 www.atriaxgroup.com
03/31/23
B
IM
/2
V
A W e s t P a lm
B e a c h E
H R
M I n fr a s tr u c tu re U p g ra d e s D e s ig n /5
-7
.G
R
.r v t
/3
/2
:1
:1
A
M
FP000
FIRE PROTECTION SYMBOLS AND
ABBREVIATIONS
ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM)
INFRASTRUCTURE UPGRADES
WEST PALM BEACH, FL
548-22-700
03/31/2023 TP AEA
FIRE ALARM SYMBOL LEGEND
PLAN SYMBOL NAME DESCRIPTION
DETECTOR - SYSTEM DUCT
SMOKE DETECTOR
PROVIDE SYSTEM DUCT SMOKE DETECTOR IN ACCESSIBLE LOCATION. PROVIDE REMOTE STATUS INDICATOR AND
TEST STATION AND COORDINATE ASSOCIATED MOUNTING LOCATION WITH OWNER.
FIRE ALARM CONTROL PANEL -
SURFACE MOUNT
CIRCUIT CONTROL PANEL TO 20A 120V BRANCH CIRCUIT IN ASSOCIATED LIFE SAFETY/EMERGENCY BRANCH PANEL (INSTALL CIRCUIT BREAKER LOCK ON BRANCH BREAKER) REFER TO ELECTRICAL FOR REQUIREMENTS. PROVIDE SYSTEM SMOKE DETECTOR AT CEILING WITHIN 5 FEET OF PANEL (UNLESS SHOWN WITH ROOM DETECTION COVERAGE ON PLAN). PROVIDE TWO (2) VOICE CONNECTIONS TO FACP. REFER TO TELECOMMUNICATIONS FOR
FURTHER DETAILS.
FIRE ALARM POWER
SUPPLY/AMPLIFIER
CIRCUIT FIRE ALARM POWER SUPPLY / AMPLIFIER PANEL TO 20A 120V BRANCH CIRCUIT IN ASSOCIATED LIFE SAFETY/EMERGENCY BRANCH PANEL (INSTALL CIRCUIT BREAKER LOCK ON BRANCH BREAKER). REFER TO ELECTRICAL FOR FURTHER DETAILS. COORDINATE EXACT QUANTITY AND LOCATIONS WITH MANUFACTURER SHOP
DRAWINGS.
FIRE SPRINKLER VALVE TAMPER
SWITCH
PROVIDE FIRE SPRINKLER VALVE TAMPER SWITCH AT FIRE SPRINKLER SERVICE AND ALL FIRE SPRINKLER ZONE
VALVES THROUGHOUT PROJECT.
FIRE SPRINKLER WATER FLOW
SWITCH
PROVIDE FIRE SPRINKLER WATER FLOW SWITCH AT FIRE SPRINKLER SERVICE AND ALL FIRE SPRINKLER ZONE
VALVES THROUGHOUT PROJECT.
FIRE SUPPRESSION CONTROL
PANEL
CIRCUIT FIRE SUPPRESSION CONTROL PANEL TO 20A 120V BRANCH CIRCUIT IN ASSOCIATED LIFE SAFETY/EMERGENCY BRANCH PANEL (INSTALL CIRCUIT BREAKER LOCK ON BRANCH BREAKER). REFER TO ELECTRICAL FOR FURTHER DETAILS. PROVIDE FIRE ALARM CONTROL MODULE, VALVE TAMPER SWITCH, AND FIRE ALARM MONITORING MODULE FOR FIRE ALARM SYSTEM MONITORING. PROVIDE TWO (2) VOICE CONNECTIONS TO
FSCP. REFER TO TELECOMMUNICATIONS FOR FURTHER DETAILS.
SMOKE DAMPER OR FIRE/SMOKE
DAMPER
CIRCUIT FIRE AND FIRE/SMOKE DAMPERS PROVIDED BY MECHANICAL CONTRACTOR TO 20A 120V BRANCH CIRCUITS IN ASSOCIATED LIFE SAFETY/EMERGENCY BRANCH PANEL (INSTALL CIRCUIT BREAKER LOCK ON BRANCH BREAKERS). REFER TO ELECTRICAL FOR FURTHER DETAILS. PROVIDE INDIVIDUAL CIRCUITS FOR EACH AIR HANDLING UNIT ZONE. REFER TO MECHANICAL PLANS FOR ASSOCIATED ZONES. CONTROL EACH DAMPER INDIVIDUALLY WITH ADDRESSABLE CONTROL MODULES FROM FIRE ALARM SYSTEM. LABEL EACH RELAY WITH THE NAME OF THE AIR HANDLING UNIT SERVING THE SMOKE ZONE AND WITH THE WORDS "SMOKE DAMPER CONTROL".
CONTROL DAMPER BY ACTIVATION OF ANY SMOKE DETECTOR WITHIN AIR HANDLING UNIT ZONE. PROVIDE REMOTE STATUS INDICATOR AND TEST STATION FOR DETECTOR AND COORDINATE ASSOCIATED MOUNTING LOCATION WITH OWNER. REFER TO FIRE PROTECTION AND ELECTRICAL FLOOR PLANS FOR DAMPER LOCATIONS.
FIRE ALARM SYMBOLS
PLAN SYMBOL NAME
DETECTOR - SYSTEM SMOKE -
CEILING
FIRE ALARM REMOTE
ANNUNCIATOR
MANUAL PULL STATION
STROBE - CEILING
VOICE/TONE SPEAKER - CEILING
VOICE/TONE SPEAKER - WALL
VOICE/TONE SPEAKER AND
STROBE COMBINATION - CEILING
VOICE/TONE SPEAKER AND
STROBE COMBINATION - WALL
FIRE ALARM COORDINATION LEGEND
SYSTEMS
ROUGH-INS &
PATHWAYS
CABLING &
TERMINATIONS
DEVICES &
EQUIPMENT REMARKS
FIRE ALARM CF / CI CF / CI CF / CI 1
Revisions: Date:
UP
J
H
G8
G
E
D
C8
C
B
A8
A6
A
H4
1 2 3 4 5 6
8 9 9.2 9.8 10.4 11.2 11.812.2 13
14 15 16 17
1818.2 19 19.6 19.8
20.821.2 22 23
24 25 26 27
AREA A
AREA B
AREA C
AREA D
AREA E
AREA F
AREA G
G.8
9.8
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
102 3rd Avenue, NE PO Box 1629, Hickory, NC 28603 T: 828.315.9962 F: 828.315.9964 www.atriaxgroup.com 03/31/23
B
IM
/2
V
A W e s t
P a lm B e a c h
E H
R M
I n fr a s tr u c tu re U p g ra d e s D e s ig n /5
-7
.B
.M T
R
.r v t
/3
/2
:3
:4
A
M
B01-FP100
BASEMENT LEVEL FLOOR PLAN -
FIRE PROTECTION
ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM)
INFRASTRUCTURE UPGRADES
WEST PALM BEACH, FL
548-22-700
B01
03/31/23 JWB NLC
1" = 20'-0"1
BASEMENT LEVEL FLOOR PLAN - OVERALL - FIRE PROTECTION
PLAN NORTH
20 20 40
1" = 20'-0"
FEETSCALE
F
F
J
H
G8
G
E
D
C8
C
H4
1 2 3 4 5 6
8 9 9.2 9.8
MAIL ROOM
BA-215
TELE.
BB-121
CHIEF LOGISTIC
SERVICE
BB-306
CORR.
BB-302B
STAIR 5
ST-5
PNEUMATIC TUBE FAN
ROOM
BB-302A
EMS
BA-312
LAB/PATH
BA-310
CANTEEN RECEIVING
BA-308
EMS STORAGE
BA-306REFRIGERAT BODY
HOLDING
BA-305
MED GAS
BA-303
MED GAS
BA-301
OFFICE SUPPLIES
BA-212
OFFICE
STOREKEEPER
BA-210
HAC
BA-202
LOGISTICS PROPERTY
MANAGEMENT
BA-207
OFFICE
BB-205
OFFICE
BB-207
STORAGE
BB-209
ASST. CHIEF HIMS
BA-118
PROGRAM
COORDINATOR
BA-106A
MAS ADMIN. SUPERV.
BA-103
VTP MANAGER
BA-121
CHIEF AMBULATORY
BA-120
CHIEF HIMS
BA-119
AUTO CART WASH
BA-225
MANUAL EQUP. WASH
BA-227
MALE LOCKERS
BA-235
FEMALE TOILET
BA-234A
FEMALE LOCKERS
BA-243
HAC
BA-249
RME EDUCATOR
BA-252
SPS ASSISTANT CHIEF
BA-245
SRS CHIEF
BA-246
QA SPECIALIST
BA-244
CLEAN RECEIVING &
BREAKOUT
BA-241FEMALE LOCKSER
BA-234
HAC
BA-229
MALE TOILET
BA-233A
MALE LOCKERS
BA-233
ANTE/GOWNING RM.
BA-232
MALE TOILET
BA-235A
MECH. ROOM
BA-215B
DECONTAMINATION
ROOM
BA-221
MACHINE
BA-110
TELEPHONE
SWITCHGEAR
BA-112
HIMS SUPV.
BA-115
ELECT ROOM
BA-114
FEMALE TOILET
BA-243A
ANTE/GOWNING RM.
BA-242 LOGISTICS OFFICE
BA-254A
LOGISTICS OFFICE
BA-254
OFFICE
BA-261B
OFFICE
BA-261A
FEMALE LOCKERS
BA-271
ELEC.
BB-307
FEMALE TOILETS
SHOWERS
BA-271A
OFFICE
BA-261C
ASST. CHEIF
AMUBLATORY CARE
BA-107
ROOM
BA-108
DISTRIB. SECTION
BA-106
PREPARATION
ASSEMBLY
BA-251A
UPS ELEC. RM.
BB-312B
UPS ELEC. RM.-2
BB-312B-2
MECH.
BB-312C
ANE-ROOM
BA-304
SOILEED SERVICE
LOBBY
BB-302
MALE LOCKERS
BA-272
MALE TLTS.
SHOWERS
BA-272A
MECHANCIAL
BB-304
STAFF TLT
BA-204
STORAGE
BA-206
PIV OPERATIONS
BA-261
OFFICE
BA-261
CORRIDOR
BD-C1
STAIR 4
6A-311
WAREHOUSE
RECEIVING
BA-201
CORR.
BA-C1
CORR.
BA-C2
DISP. ADMIN.
SCHEDULING MAS
CONTROL
BA-104
OPERATIONS ROOM
BB-204
CONSOLE ROOM
BB-206
CORR.
BA-C4
SUPPLY/EQUIP.
STORAGE
BA-251
MANAGEMENT
MATERIAL
BA-106B
ADMIN.
OFFICES/CUBICALS
BA-102
ASST. CHIEF MAS
BA-105
STAIR #2-1
STAIR-1
BENEFICIAL TRAVEL
BA-101
MAIL ROOM
BA-215A
TR
BA-216
B01-FP100A
B01-FP100A
G.8
9.8
E
E W
TR
BA-216
E
WE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
102 3rd Avenue, NE PO Box 1629, Hickory, NC 28603 T: 828.315.9962 F: 828.315.9964 www.atriaxgroup.com
KEYPLAN
PLAN NORTH
AREA A
03/31/23
B
IM
/2
V
A W e s t
P a lm B e a c h
E H
R M
I n fr a s tr u c tu re U p g ra d e s D e s ig n /5
-7
.B
.M T
R
.r v t
/3
/2
:3
:5
A
M
B01-FP100A
BASEMENT LEVEL FLOOR PLAN -
AREA A - FIRE PROTECTION
ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM)
INFRASTRUCTURE UPGRADES
WEST PALM BEACH, FL
548-22-700
B01
03/31/23 JWB NLC
1/16" = 1'-0"1
BASEMENT LEVEL FLOOR PLAN - AREA A - FIRE PROTECTION
5 5 10 15 20 25 30 35 40 45
1/16" = 1'-0"
FEETSCALE
1/4" = 1'-0"3
BASEMENT LEVEL - TR BA-216 -NEW - FIRE PROTECTION
1/4" = 1'-0"2
BASEMENT LEVEL - MAIL ROOM - DEMOLITION - FIRE PROTECTION
A. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
B. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN DASHED, EXISTING
MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER PLANS, NEW
MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.
C. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL
PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.
D. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO
PERFORM THIS WORK.
GENERAL NOTES:
SHEET NOTES:
1. DEMOLISH EXISTING SPRINKLER HEAD AND PIPING BACK TO ROOM PERIMETER. REFER TO NEW PLAN FOR
ADDITIONAL INFORMATION.
2. PROVIDE NEW SPRINKLER(S) IN TR ROOM PER NFPA 13 REQUIREMENTS. NO SPRINKLER PIPING OR SPRINKLERS TO BE LOCATED OVER THE TOP ON NEW EQUIPMENT RACKS. PROVIDE STANDARD RESPONSE
HEADS WITH FUSIBLE LINKS AND PROTECTIVE WIRE CAGES.
3. REMOVE ANY EXISTING FIRE ALARM NOTIFICATION OR DETECTION DEVICES WITHIN ROOM UNLESS OTHERWISE INDICATED. MODIFY ANY EXISTING FIRE ALARM CIRCUITS TO MAINTAIN EXISTING FUNCTION.
4. EXTEND EXISTING FIRE ALARM SYSTEM CIRCUIT UTILIZING 3/4" C. AND WIRING AS REQUIRED BY
MANUFACTURER'S REQUIREMENTS.
2 2 4 6 8 10
1/4" = 1'-0"
FEETSCALE
2 2 4 6 8 10
1/4" = 1'-0"
F F
J
H
G8
G
E
D
C8
C
H4
9.8 10.4 11.2 11.812.2 13 14 15 16 17 1818.2
SWITCHBOARD
BC-261
TELE.
BB-121
HAC
BB-316
CHIEF LOGISTIC
SERVICE
BB-306
CORR.
BB-302B
ELEV.-1
S-5-1
ELEV.-1
S-4-1
EVIDENCE STORAGE
BB-204A
HOLDING
BB-203
OFFICE
BB-205
INTERVIEW
BB-203
OFFICE
BB-207
STORAGE
BB-209
MAS ADMIN. SUPERV.
BA-103
PEST CONTROLLER
BB-334
PEST CONTROLLER
BB-332
MACHINE REPAIR
SHOP
BB-338
STAFF TLT.
BC-261A
FREEZER
BB-253
MEAT REFRIGERATOR
BB-239
FEMALE LOCKERS
BA-271
NOURISHMENT
PREPARATION
BB-233
OFFICE
BB-219A
ELEC. CLOS.
BB-213
SUPERVISOR TECH.
AND CLERKS
BB-235
PROGRAM MGM'T 8
PLANNING
BB-219B
CLERK
BB-219
UNIFORM ROOM
BB-237A
AUTO VALER ALCOVE
BB-217
TELE SWITCH
BB-215
FOOD SERVICE
COORDINATION
CENTER
BB-237
POISON CONTROL
BB-112
ELEC.
BB-307
PROGRAM SUPPORT
BB-258
NON-FOOD STORAGE
BB-259
COMPUTER ROOM
BC-202
DRUG INFOR SERVICE
BB-118
PHARM SUPERVISOR
BB-121A
CONTROL
SUBSTANCE
BB-116
CORR.
BB-312A
MATERIAL
MANAGEMENT
BB-322
MECHANICAL ROOM
BB-314
SANITARY
BB-245
HAC
BB-246
BLAST CHILLER
BB-248
REFRIG.
BB-249
FOOD STORAGE
BB-254
HAC
BB-256
DAIRY COOLER
BB-257
GENERAL COOLER
BB-255
OFFICE
BC-263A
OFFICE
BC-263B
OFFICE
BC-263C
OFFICE
BC-263D
TELECOMM
BC-263
ADP STORGE
NON-SECURE
BC-304
TRASH
BC-302
CORR.
BB-C4
CAN WASH
BB-223
CONFERENCE/CLASSROOM
BB-225
ASSISTANT CHIEF
BB-236
COOK FOREMAN
BB-238
ELEV.-1
P-6-1
ELEV.-1
P-1-1
ELEV.-1
S-3-1
ELEV.-1
S-2-1
ELEV.-1
S-1-1UPS ELEC. RM.
BB-312B
UPS ELEC. RM.-2
BB-312B-2
CLEAN SERVICE
LOBBY
BB-312
MECH.
BB-312C
SOILEED SERVICE
LOBBY
BB-302
MALE LOCKERS
BA-272
EQUIP. TECH WORK
BC-202A
CORR.
CB-44
CORRIDOR
BD-C1
BATTERY CHARGE
BB-336
N & FS SUPERVISOR
BB-234
SUPERV. OFFICE
BB-232
PHARMACY ADMIN.
BB-121
POT WASHING
BB-252
FOOD
PROCESSING/PREPARATION
BB-251
CORR.
BB-251
WARE WASHING
BB-243
CLEANING
EQUIPMENT ROOM
BB-243A
CART WASH
BB-242
CART STORAGE
BB-241
WAITING
BB-212
CREDIT UNION
TELLER
BB-212B
CORR.
BB-C2
CORR.
CB-7
CORR.
BA-C1
DISP. ADMIN.
SCHEDULING MAS
CONTROL
BA-104
SECURITY ROOM
BB-202
OPERATIONS ROOM
BB-204
CONSOLE ROOM
BB-206
CORR.
BA-C3
SEAMSTRESS
BB-324A
SEAMSTRESS
BB-324
MECHANICAL-1
BC-314-1
VESTIBULE
BB-C1
STAIR 6
STAIR 6
PHARMACY SERVICE
BB-111
CREDIT UNION
OFFICE
BB-212A
BENEFICIAL TRAVEL
BA-101
CORR.
BB-121
TR
BB-221A
CHIEF
BB-221
ASSOC. CHIEF
BB-122
CHIEF
BB-125
B01-FP100C
B01-FP100C
G.8
9.8
E
TR
BB-221A
E
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
102 3rd Avenue, NE PO Box 1629, Hickory, NC 28603 T: 828.315.9962 F: 828.315.9964 www.atriaxgroup.com
KEYPLAN
PLAN NORTH
AREA C
03/31/23
B
IM
/2
V
A W e s t
P a lm B e a c h
E H
R M
I n fr a s tr u c tu re U p g ra d e s D e s ig n /5
-7
.B
.M T
R
.r v t
/3
/2
:3
:5
A
M
B01-FP100C
BASEMENT LEVEL FLOOR PLAN -
AREA C - FIRE PROTECTION
ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM)
INFRASTRUCTURE UPGRADES
WEST PALM BEACH, FL
548-22-700
B01
03/31/23 JWB NLC
1/16" = 1'-0"1
BASEMENT LEVEL FLOOR PLAN - AREA C - FIRE PROTECTION
1/4" = 1'-0"3
BASEMENT LEVEL FLOOR PLAN - TR BB-221A -NEW - FIRE PROTECTION
1/4" = 1'-0"2 BASEMENT LEVEL FLOOR PLAN - NUTRITION & FOOD SERVICE - DEMOLITION - FIRE PROTECTION
A. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
B. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN DASHED, EXISTING
MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER PLANS, NEW
MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.
C. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL
PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.
D. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO
PERFORM THIS WORK.
GENERAL NOTES:
SHEET NOTES:
1. DEMOLISH EXISTING SPRINKLER HEAD AND PIPING BACK TO ROOM PERIMETER. REFER TO NEW PLAN FOR
ADDITIONAL INFORMATION.
2. PROVIDE NEW SPRINKLER(S) IN TR ROOM PER NFPA 13 REQUIREMENTS. NO SPRINKLER PIPING OR SPRINKLERS TO BE LOCATED OVER THE TOP ON NEW EQUIPMENT RACKS. PROVIDE STANDARD RESPONSE
HEADS WITH FUSIBLE LINKS AND PROTECTIVE WIRE CAGES.
3. REMOVE ANY EXISTING FIRE ALARM NOTIFICATION OR DETECTION DEVICES WITHIN ROOM UNLESS OTHERWISE INDICATED. MODIFY ANY EXISTING FIRE ALARM CIRCUITS TO MAINTAIN EXISTING FUNCTION.
4. EXTEND EXISTING FIRE ALARM SYSTEM CIRCUIT UTILIZING 3/4" C. AND WIRING AS REQUIRED BY
MANUFACTURER'S REQUIREMENTS.
5 5 10 15 20 25 30 35 40 45
1/16" = 1'-0"
FEETSCALE
2 2 4 6 8 10
1/4" = 1'-0"
FEETSCALE
2 2 4 6 8 10
1/4" = 1'-0"
F
J
H
G8
G
E
D
C8
C
H4
19 19.619.8 20.821.2 22 23 24 25 26 27
LOCKSMITH
BC-322
SHOP SUPER
BC-211A
BIO. MED. REPAIR
AND DEVELOPMENT
BC-215
ELEC. CLOSET
BC-240
T/S
BC-240A
HAC
BG-129
ELEV.-1
P-10-1
ELEV.-1
P-7-1 STORAGE
BC-114A
STORAGE
BC-242C
OFFICE
BC-231B
OFFICE
BC-231D
OFFICE
BC-231C
OFFICE
BC-231E
CONF.
BC-231F
SAFETY SUPERVISOR
BC-239
HAC
BC-257
RECREATION
THERAPY
BC-262
COMPUTER TRAINING
BC-246
CHIEF VOL. REC.
THERAPY
BC-243 REFRIG.
BC-241B
FREEZER
BC-241
SUPPLIES/VOL.
SERVICE
BC-260
OUTDOOR
RECREATION
BC-261
COMP. TRAINING
BC-265
EOC
BC-255
PSA EMS
BC-257
ASST. CHIEF REC
THERAPY
BC-264
FACILITY PLANNER
BC-266
EMS FOREMAN
BC-358
AO EMS
BC-356
CHIEF EMS
BC-354
EMS
BC-352
EMS SUPER.
BC-351
STORAGE
BC-360B
WORKBENCH
BC-360A
STORAGE
BC-360
MALE TOILET
BC-340
FIRE PUMP RM.
BE-132
A/C SHOP
BE-103
DOMESTIC WATER
ROOM
BE-103
ELECT.
BC-324
TELE.
BC-316
LIFT FUTURE-1
8-1
LIFT-1
7-1
MECH CLOSET
BE-314
LOGISTICS
BC-338
COMPUTER TRAINING
BC-248
TR
BC-250
UPS ROOM
BC-202A
COMPUTER ROOM
BC-202
BIOMEDICAL
ENGINEER
BC-212
ADMIN OFF./SEC'Y
BC-203
FACILITY
MANAGEMENT
SERVICE
BC-231
BREAK ROOM
BC-215A
BIOMEDICAL
ENGINEERING
BC-231A
TELECOMM
BC-263
ADP STORGE
NON-SECURE
BC-304
CORR.
BB-C4
MRI SCANNING ROOM
BG-122
STAIR
VOLUNTEER
RECRUITMENT
BC-244
FACILITIES PLANNING
BC-253
CORR.
6A-333
VOLUNTARY SERVICE
BC-245
SAFETY OFFICE
BC-247
FREEZER
BC-241A
RECREATION
THERAPY
BC-245A
CARPENTRY SHOP
WORKROOM
BC-242
STORAGE
BC-242A
STORAGE
BC-242B
BIOMEDICAL
ENGINEERING
BC-312
ELEV.-1
S-6-1
ELEV.-1
S-7-1
ELEV.-1
S-8-1
BIOMEDICAL
ENGINEERING
BC-218
ELEC. CLOS.
BC-214
EQUIP. TECH WORK
BC-202A
FEMALE LOCKER
BC-103
FEMALE TLT.
BC-103A
PAINT SHOP
BC-342
CHIEF INFO OFFICE
BC-111 A
CORRIDOR
BC-C6
CORRIDOR
BC-C4
CORR.
BC-C4
VESTIBULE
BC-C3
ELECTRICAL SHOP
BC-213
STORAGE
BC-213A
TOOLS
BC-213B
WORKBENCH
ELECTRONIC SHOP
BC-211
CORRIDOR
BC-C2
MECHANICAL
BD-120
MECHANICAL
BD-123MECHANICAL-1
BC-314-1
AIR COMPRESSOR &
VACUUM PUMPS
BE-104
I.R.M.S. TELE
BC-114
INFORMATION
SECURITY OFFICER
BC-112 IRMS
BC-114
ELEC. CLOSET
BC-114D
IRMS STORAGE
BC-114C
ELEC. CLOSET
BG-130
RECOVERY AND
SCREENING
BG-128
LINEN ALCOVE
BG-127
CORRIDOR
BG-126
VEST
C1-17
STAIR #3-1
STAIR-1
MALE LOCKERS
BC-101
TR
BC-216
CORRIDOR
BC-C1
MECHANICAL-2
BC-314-2
MALE TLT.
BC-101A
FEMALE TOILET
BC-334
PLUMBING SHOP
BC-336
B01-FP100E
B01-FP100E
E
E E E
FACP
FAPS
19.6 19.8
1 1
R
W
19.6 19.8
R
W
BIOMEDICAL
ENGINEERING
BC-218
TR
BC-216
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
102 3rd Avenue, NE PO Box 1629, Hickory, NC 28603 T: 828.315.9962 F: 828.315.9964 www.atriaxgroup.com
KEYPLAN
PLAN NORTH
AREA E
03/31/23
B
IM
/2
V
A W e s t
P a lm B e a c h
E H
R M
I n fr a s tr u c tu re U p g ra d e s D e s ig n /5
-7
.B
.M T
R
.r v t
/3
/2
:3
:0
A
M
B01-FP100E
BASEMENT LEVEL FLOOR PLAN -
AREA E - FIRE PROTECTION
ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM)
INFRASTRUCTURE UPGRADES
WEST PALM BEACH, FL
548-22-700
B01
03/31/23 JWB NLC
1/16" = 1'-0"1
BASEMENT LEVEL FLOOR PLAN - AREA E - FIRE PROTECTION
1/4" = 1'-0"2 BASEMENT LEVEL FLOOR PLAN - BIOMEDICAL ENGINEERING - DEMOLITION - FIRE PROTECTION
1/4" = 1'-0"3
BASEMENT LEVEL FLOOR PLAN - TR BC-216 - NEW - FIRE PROTECTION
A. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
B. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN DASHED, EXISTING
MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER PLANS, NEW
MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.
C. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL
PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.
D. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO
PERFORM THIS WORK.
GENERAL NOTES:
SHEET NOTES:
1. DEMOLISH EXISTING SPRINKLER HEAD AND PIPING BACK TO ROOM PERIMETER. REFER TO NEW PLAN FOR
ADDITIONAL INFORMATION.
2. PROVIDE NEW SPRINKLER(S) IN TR ROOM PER NFPA 13 REQUIREMENTS. NO SPRINKLER PIPING OR SPRINKLERS TO BE LOCATED OVER THE TOP ON NEW EQUIPMENT RACKS. PROVIDE STANDARD RESPONSE
HEADS WITH FUSIBLE LINKS AND PROTECTIVE WIRE CAGES.
3. REMOVE ANY EXISTING FIRE ALARM NOTIFICATION OR DETECTION DEVICES WITHIN ROOM UNLESS OTHERWISE INDICATED. MODIFY ANY EXISTING FIRE ALARM CIRCUITS TO MAINTAIN EXISTING FUNCTION.
4. EXTEND EXISTING FIRE ALARM SYSTEM CIRCUIT UTILIZING 3/4" C. AND WIRING AS REQUIRED BY
MANUFACTURER'S REQUIREMENTS.
5 5 10 15 20 25 30 35 40 45
1/16" = 1'-0"
FEETSCALE
2 2 4 6 8 10
1/4" = 1'-0"
FEETSCALE
2 2 4 6 8 10
1/4" = 1'-0"
J
1818.2 19 19.619.8 20.821.2 22 23
FPL SWITCH ROOM
BE-144
N2 MANIFOLD
BE-136
N20 MANIFOLD
BE-134
FIRE PUMP RM.
BE-132
A/C SHOP
BE-103
DOMESTIC WATER
ROOM
BE-103
MECH CLOSET
BE-314
OPERATIONS
STORAGE
BE-123
CHILLER ROOM
BE-102
GENERATOR ROOM
BE-142
TE
BE-113
CONF/TRAINING
ROOM
BE-116
CORR.
BE-110
FEMALE TLTS.
BE-114
LOCKERS
BE-112
ELECTRICAL
SWITCHGEAR ROOM
BE-141
MECHANICAL
BD-123MECHANICAL-1
BC-314-1
AIR COMPRESSOR &
VACUUM PUMPS
BE-104
CONTROL ROOM
BE-111
OFFICE
BE-111A
BOILER ROOM
BE-121
B01-FP100G
B01-FP100G
TE
BE-113
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
102 3rd Avenue, NE PO Box 1629, Hickory, NC 28603 T: 828.315.9962 F: 828.315.9964 www.atriaxgroup.com
KEYPLAN
PLAN NORTH
AREA G
03/31/23
B
IM
/2
V
A W e s t
P a lm B e a c h
E H
R M
I n fr a s tr u c tu re U p g ra d e s D e s ig n /5
-7
.B
.M T
R
.r v t
/3
/2
:3
:0
A
M
B01-FP100G
BASEMENT LEVEL FLOOR PLAN -
AREA G - FIRE PROTECTION
ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM)
INFRASTRUCTURE UPGRADES
WEST PALM BEACH, FL
548-22-700
B01
03/31/23 JWB NLC
1/16" = 1'-0"1
BASEMENT LEVEL FLOOR PLAN - AREA G - FIRE PROTECTION
1/4" = 1'-0"2
BASEMENT LEVEL FLOOR PLAN - BOILER ROOM - DEMOLITION - FIRE PROTECTION
1/4" = 1'-0"3
BASEMENT LEVEL FLOOR PLAN - TE BE-113 - NEW - FIRE PROTECTION
A. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
B. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN DASHED, EXISTING
MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER PLANS, NEW
MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.
C. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL
PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.
D. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO
PERFORM THIS WORK.
GENERAL NOTES:
SHEET NOTES:
1. DEMOLISH EXISTING SPRINKLER HEAD AND PIPING BACK TO ROOM PERIMETER. REFER TO NEW PLAN FOR
ADDITIONAL INFORMATION.
2. PROVIDE NEW SPRINKLER(S) IN TR ROOM PER NFPA 13 REQUIREMENTS. NO SPRINKLER PIPING OR SPRINKLERS TO BE LOCATED OVER THE TOP ON NEW EQUIPMENT RACKS. PROVIDE STANDARD RESPONSE
HEADS WITH FUSIBLE LINKS AND PROTECTIVE WIRE CAGES.
3. REMOVE ANY EXISTING FIRE ALARM NOTIFICATION OR DETECTION DEVICES WITHIN ROOM UNLESS OTHERWISE INDICATED. MODIFY ANY EXISTING FIRE ALARM CIRCUITS TO MAINTAIN EXISTING FUNCTION.
4. EXTEND EXISTING FIRE ALARM SYSTEM CIRCUIT UTILIZING 3/4" C. AND WIRING AS REQUIRED BY
MANUFACTURER'S REQUIREMENTS.
5 5 10 15 20 25 30 35 40 45
1/16" = 1'-0"
FEETSCALE
2 2 4 6 8 10
1/4" = 1'-0"
FEETSCALE
2 2 4 6 8 10
1/4" = 1'-0"
H
G8
G
E
D
C8
C
B
A8
A6
A
H4
1 2 3 4 5 6
8 9 9.2 9.8 10.4 11.2 11.812.2 13
14 15 16 17
1818.2 19 19.619.8 20.821.2 22 23
24 25 26 27
AREA A
AREA B
AREA C
AREA D
AREA E
AREA F
AREA G
G.8
9.8
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
102 3rd Avenue, NE PO Box 1629, Hickory, NC 28603 T: 828.315.9962 F: 828.315.9964 www.atriaxgroup.com 03/31/23
B
IM
/2
V
A W e s t
P a lm B e a c h
E H
R M
I n fr a s tr u c tu re U p g ra d e s D e s ig n /5
-7
.B
.M T
R
.r v t
/3
/2
:3
:1
A
M
B01-FP101
FIRST LEVEL FLOOR PLAN - FIRE
PROTECTION
ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM)
INFRASTRUCTURE UPGRADES
WEST PALM BEACH, FL
548-22-700
B01
03/31/23 JWB NLC
1" = 20'-0"1
FIRST LEVEL FLOOR PLAN - OVERALL - FIRE PROTECTION
PLAN NORTH
20 20 40
1" = 20'-0"
F
J
H
G8
G
E
D
C8
C
H4
1 2 3 4 5 6
8 9 9.2 9.8
ROOM
1A-149
SUPERVISOR HEALTH
BENEFITS
1A-143
ROOM
1A-147
ELEC.
1A-145
ELEC.
1A-191
ROOM
1A-193
DISP. TECH. AREA
1A-207
DOCTOR'S OFFICE
1A-242
COMP. & PENSIONS
1A-237
COMP. & PENSIONS
1A-239
EXAM
1A-235
EXAM ROOM 4
1A-248
EXAM ROOM 3
1A-246
PROSTHETICS
1A-244
OFFICE
1A-233
F. TLT
1A-234
OFFICE
1A-225
EXAM
1A-227
DOCTOR'S OFFICE
1A-222
EXAM ROOM
1A-224
OFFICE
1A-226
DOCTOR'S OFFICE
1A-228
CORRIDOR
1A-C4
OFFICE
1A-210
EXAM
1A-212
WALK IN CLINIC
1A-214
EXAM
1A-216
OFFICE
1A-345F OFFICE
1A-345E
EXAM ROOM 6
1A-247
HAC
1A-252
SHOWER ROOM
1A-247A
DERM LAB
1A-254
ELEC.
1A-259
OFFICE
1A-254A
OFFICE
1A-251
W/C TLT
1A-248A
EXAM ROOM 5
1A-250
STAFF TLT
1A-245
PSYCHOLOGIST
1A-267
EXAM TREAT 7
1A-284
TELE SWITCH
1A-275
CORR.
1A-C6
X-RAY
1A-134
TLT
1A-138
CLEAN UTILITY
1A-110
EXAM / TREATMENT
1A-106
EXAM / TREATMENT
1A-107
EXAM / TREATMENT
1A-108
EXAM / TREATMENT
1A-109
PHYSICIAN OFFICE
1A-204
CLERK
1A-221
CONTROL ROOM
1A-109
CT SCAN
1A-128
OFFICE
1A-304
SOCIAL WORKER
1A-314
OFFICE
1A-302
EXAM
1A-218
MALE TLT
1A-322A
NURSE MANAGER
1A-318
PATIENT ADVOCATE
1A-346
DOCTOR'S OFFICE
1A-332
PATIENT ADVOCATE
1A-344
OFFICER
1A-333
CAST STOR. ROOM
1A-274A
EXAM TREAT 1
1A-262
OFFICE
1A-274
FAMILY ROOM
1A-270
OFFICE
1A-257
CORR.-1
1A-C8-1
LACTATION
1A-273
MED. ROOM
1A-276
OFFICE
1A-288
SOCIAL WORKER
1A-278
SP 1 HAC
1A-277
OFFICE
1A-286
W/C TLT
1A-273A
EXAM TREAT 4
1A-289
EXAM TREAT 3
1A-287
OFF/OIF
1A-283
W/C TLT
1A-281A
M. TLT
1A-294
F. TLT
1A-292
OFF/OIF
1A-281
OFFICE
1A-285
CORR.-2
1A-C8-2
OFFICE
1A-282
OFFICE
1A-255
STAIR #5-1
STAIR-1
STAIR 2
STAIRFEMALE TOILET
1A-176
MALE TOILET
1A-174
OCCUPATIONAL
HEALTH
1A-306
OFFICE
1A-308
MALE LKRS
1A-322
STAFF TLT
1A-341
ELECTRICAL
1B-306
TEL.
1B-308
SOILED UTILITY
1A-111
SUPPLY ROOM
1A-241
ROOM
1A-243
EXAM
1A-240
OFFICE
1A-312
OCCUPATIONAL
HEALTH
1A-301
FEMALE LKRS.
1A-331
FEMALE TOILET
1A-331A
NURSE MANAGER
1A-324
OFFICE
1A-326
STAIR 4
STAIR
TLT
1A-132
MALE TLT
1A-232
GYN./TLT DRESS
1A-285A
MECHANICAL
1A-316
CORR.
1A-316
NURSE MANAGER
1A-206
NURSE ON DUTY
1A-208
CORR.
1A-C5
PATIENT WAITING
1A-220
VITALS
1A-253
WAITING
1A-264
RECEPTION
1A-268
MANAGER
1A-279
MAS CONTROL SP2
PROCESS
1A-261
MECHANICAL
1A-314
VEST
C1-170
SOILED LINEN CHUTE
VEST
1B-303
SOILED SERVICE
1B-302
OFFICE
1A-343
SP2 HAC
1A-368
NURSE MNGR.
1A-366
CORR.
1B-314
TRASH
1A-362
DECEDENT AFFAIRS
1A-354STAFF TLT
1A-352
CORR.
1A-340
PATIENT ADVOCATE
1A-342
OFFICE
1A-334
CORR.
1A-C7
MULTI PURPOSE
1A-171D
MULTI PURPOSE
1A-171A
MULTI PURPOSE
1A-171C
PATIENT WAITING SP1
& SP2
1A-260
CORR.
1A-170
OFFICE
1A-171E
OFFICE
1A-171F
OFFICE
1A-171H
OFFICE
1A-171J
OFFICE
1A-171I
CORR.
1A-C2
CORR.
1A-C3
TR
1A-148
NURSE ESCORT
1A-144
WOMENS CLINIC
NURSE
1A-272
PRIMARY CARE
1A-231
B01-FP101A
B01-FP101A
G.8
9.8
D
C8
R W
D
C8
R
W
TR
1A-148
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
102 3rd Avenue, NE PO Box 1629, Hickory, NC 28603 T: 828.315.9962 F: 828.315.9964 www.atriaxgroup.com
KEYPLAN
PLAN NORTH
AREA A
03/31/23
B
IM
/2
V
A W e s t
P a lm B e a c h
E H
R M
I n fr a s tr u c tu re U p g ra d e s D e s ig n /5
-7
.B
.M T
R
.r v t
/3
/2
:3
:1
A
M
B01-FP101A
FIRST LEVEL FLOOR PLAN - AREA
A - FIRE PROTECTION
ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM)
INFRASTRUCTURE UPGRADES
WEST PALM BEACH, FL
548-22-700
B01
03/31/23 JWB NLC
1/16" = 1'-0"1
FIRST LEVEL FLOOR PLAN - AREA A - FIRE PROTECTION
1/4" = 1'-0"2
FIRST LEVEL FLOOR PLAN - OFFICE - DEMOLITION - FIRE PROTECTION
1/4" = 1'-0"3
FIRST LEVEL FLOOR PLAN - TR 1A-148 - NEW - FIRE PROTECTION
A. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
B. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN DASHED, EXISTING
MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER PLANS, NEW
MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.
C. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL
PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.
D. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO
PERFORM THIS WORK.
GENERAL NOTES:
SHEET NOTES:
1. DEMOLISH EXISTING SPRINKLER HEAD AND PIPING BACK TO ROOM PERIMETER. REFER TO NEW PLAN FOR
ADDITIONAL INFORMATION.
2. PROVIDE NEW SPRINKLER(S) IN TR ROOM PER NFPA 13 REQUIREMENTS. NO SPRINKLER PIPING OR SPRINKLERS TO BE LOCATED OVER THE TOP ON NEW EQUIPMENT RACKS. PROVIDE STANDARD RESPONSE
HEADS WITH FUSIBLE LINKS AND PROTECTIVE WIRE CAGES.
3. REMOVE ANY EXISTING FIRE ALARM NOTIFICATION OR DETECTION DEVICES WITHIN ROOM UNLESS OTHERWISE INDICATED. MODIFY ANY EXISTING FIRE ALARM CIRCUITS TO MAINTAIN EXISTING FUNCTION.
4. EXTEND EXISTING FIRE ALARM SYSTEM CIRCUIT UTILIZING 3/4" C. AND WIRING AS REQUIRED BY
MANUFACTURER'S REQUIREMENTS.
5 5 10 15 20 25 30 35 40 45
1/16" = 1'-0"
FEETSCALE
2 2 4 6 8 10
1/4" = 1'-0"
FEETSCALE
2 2 4 6 8 10
1/4" = 1'-0"
F
J
H
G8
G
E
D
C8
C
H4
9.8 10.4 11.2 11.812.2 13 14 15 16 17 1818.2
TR
1B-238
SUPPLIES
1B-113
ELEV.-2
P-1-2
ELEV.-2
P-6-2
STAIR #1-1
STAIR-1
RADIOLOGIST
1B-148
ELEV.-2
S-5-2
ELEV.-2
S-4-2
ELEV.-2
S-3-2
ELEV.-2
S-2-2
ELEV.-2
S-1-2
F. PUBLIC TOILET
1B-205
TELE/ SWITCH
1B-214
ELEC.
1B-212
TLT.
1B-291C
F. TLT.
1B-257A
M. TLT.
1B-259A
CARDIOLOGY
1C-202
WAITING
1C-201
PATIENT TOILET
1C-201A
THCH OFFICE
1C-206
THYROID UP TAKE
1C-217
W/C TOILET
1C-219
HAC
1C-304
PREP ROOM
1B-339C
TOILET
1B-339B
STAFF RADIOLOGIST
1B-330
STERILE SUPPLY
1B-339A
RADIOLOGY OFFICE
1B-331
CORR.
1B-C9
RADIOLOGY OFFICE
1B-333
SECRETARY WAITING
1B-332
EQUIP. STOR.
1B-318
STORAGE
1B-272
ELEC.
1B-211
RADIOLOGIST
1B-287
AUDIOLOGIST
1B-234
ROOM
1B-236
LOUNGE
1B-267
BONE DENSITY
1B-213
CHIEF TECH.
1B-261
MAMMOGRAPHY
1B-221A
W.C. TLT.
1B-223
TLT.
1B-225
H.B.A. COORD
1B-215
M. PUBLIC TOILET
1B-207
ELECTRICAL
1B-306
UPS ELEC. RM.
1B-312A
MECH.
1B-312B
TOILET
1B-346A
TRASH
1C-302
CHIEF
TECHNOLOGIST
1B-346B
TEL.
1B-308
RADIOL. OFFICE
1B-336
RADIOL. OFFICE
1B-338
SCAN ROOM 1
1B-339F TEMP. STORAGE IRM
1B-346
TLT.
1B-293C
TLT.
1B-293B
M. STAFF LOCKERS
1B-259
DARK RM
1B-263
PATIENT SERVICE
1B-314
CLEAN SERVICE
LOBBY
1B-312
EQUIPMENT
CALIBRATION
ROOM/COMPUTER
1C-211
CONTROL ROOM
1C-205
ULTRA SOUND
1C-203
UNEXPOSED FILM &
CHEM. STOR.
1B-265
STAIR #6-1
STAIR-1
EXAM
1B-151
PHYSICIANS VIEWING
ROOM
1C-213
SOTOPIC STOR. PREP.
ROOM
1C-209
MECHANICAL
1B-314
SOILED LINEN CHUTE
VEST
1B-303
SOILED SERVICE
1B-302
RECEIVING
1B-111
VEST.
1B-C1
CORR.-1
1B-C2-1
CORR.-2
1B-C2-2
DRESS-1
1B-221-1
VEST.
1B-221
DRESS-2
1B-221-2
RADIOLOGY CHECK IN
1B-209
SEATING AREA
1B-C7
DRESS
1B-229
DRESS-1
1B-227-1
DRESS-2
1B-227-2
INPATIENT WAITING
1B-227
DRESS-3
1B-227-3
HOLDING
1B-339D
HOLDING
1B-339E
SCAN ROOM 2
1B-339H
WAITING ROOM
1B-339
CONTROL ROOM
1B-339G
AUTOMATED ROOM
1B-227A
CONTROL
1B-227A
DEDICATED CHEST
ROOM
1B-227B
CONTROL
1B-227B
FILM PROCESS
1B-255
FILM PROCESS
1B-253
RAD. / FLUOR.
1B-293A
CONTROL
1B-293A
X-RAY 1
1B-291B
X-RAY 2
1B-291A
CONTROL
1B-C1
DRESS-1
1B-291-1
VEST.
1B-291 DRESS-2
1B-291-2
DRESS-3
1B-291-3
DRESS-1
1B-293-1
DRESS-2
1B-293-2
VEST.
1B-293
X-RAY
1B-221B
CONTROL
1B-221B
WAITING
IC-208
OFFICE SEC'Y
WAITING
1C-204
CORR.
1B-C7
SCRUB
1B-C4
RADIOLOGY STOR.
1B-295
HAC
1B-288
ANGIO RECOVERY
1B-286
CORR.
1C-C2
CORR.
1B-C4
UNDER
CONSTRUCTION
RECTILINEAR ORGAN
SCAN
1C-212
SPECIAL
PROCEDURES BRIGHT
VIEW
1C-210
STATION IMAGING
1C-214
CORR.
1B-C1
OFFICE RECEPTION
1B-224
OFFICE
1B-222
STAFF LOCKERS
1B-257
LOBBY WAITING
1B-200
PHARMACY OUT
PATIENT
1B-117
DISP. / SCVS. SOCIAL
WORKER
1B-240
TRAVEL CLERK
OFFICE
1B-119
CORR.
1C-C4
RADIOLOGIST
1B-146
UPS ELEC. RM.
1B-312A
B01-FP101C
B01-FP101C
G.8
9.8
C8
R
C8
R
TR
1B-238
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
102 3rd Avenue, NE PO Box 1629, Hickory, NC 28603 T: 828.315.9962 F: 828.315.9964 www.atriaxgroup.com
KEYPLAN
PLAN NORTH
AREA C
03/31/23
B
IM
/2
V
A W e s t
P a lm B e a c h
E H
R M
I n fr a s tr u c tu re U p g ra d e s D e s ig n /5
-7
.B
.M T
R
.r v t
/3
/2
:3
:2
A
M
B01-FP101C
FIRST LEVEL FLOOR PLAN - AREA
C - FIRE PROTECTION
ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM)
INFRASTRUCTURE UPGRADES
WEST PALM BEACH, FL
548-22-700
B01
03/31/23 JWB NLC
1/16" = 1'-0"1
FIRST LEVEL FLOOR PLAN - AREA C - FIRE PROTECTION
1/4" = 1'-0"2
FIRST LEVEL FLOOR PLAN - MALE SUPERVISOR - DEMOLITION - FIRE PROTECTION
1/4" = 1'-0"3
FIRST LEVEL FLOOR PLAN - TR 1B-238 - NEW - FIRE PROTECTION
A. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
B. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN DASHED, EXISTING
MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER PLANS, NEW
MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.
C. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL
PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.
D. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO
PERFORM THIS WORK.
GENERAL NOTES:
SHEET NOTES:
1. DEMOLISH EXISTING SPRINKLER HEAD AND PIPING BACK TO ROOM PERIMETER. REFER TO NEW PLAN FOR
ADDITIONAL INFORMATION.
2. PROVIDE NEW SPRINKLER(S) IN TR ROOM PER NFPA 13 REQUIREMENTS. NO SPRINKLER PIPING OR SPRINKLERS TO BE LOCATED OVER THE TOP ON NEW EQUIPMENT RACKS. PROVIDE STANDARD RESPONSE
HEADS WITH FUSIBLE LINKS AND PROTECTIVE WIRE CAGES.
3. REMOVE ANY EXISTING FIRE ALARM NOTIFICATION OR DETECTION DEVICES WITHIN ROOM UNLESS OTHERWISE INDICATED. MODIFY ANY EXISTING FIRE ALARM CIRCUITS TO MAINTAIN EXISTING FUNCTION.
4. EXTEND EXISTING FIRE ALARM SYSTEM CIRCUIT UTILIZING 3/4" C. AND WIRING AS REQUIRED BY
MANUFACTURER'S REQUIREMENTS.
5 5 10 15 20 25 30 35 40 45
1/16" = 1'-0"
FEETSCALE
2 2 4 6 8 10
1/4" = 1'-0"
FEETSCALE
2 2 4 6 8 10
1/4" = 1'-0"
G8
G
E
D
C8
C
H4
19 19.619.8 20.821.2 22 23 24 25 26 27
ELEV. (FUTURE)-1
P-7-1
ELEV.-2
P-10-2
SEC CASH
1C-237D
SECRETARY CLERK
1C-237
CHIEF
1C-237C
ASSIST. CHIEF
1C-237B
ADMIN. ASSIST.
1C-237A
ROOM
1C-222B
THYROID UP TAKE
1C-217
W/C TOILET
1C-219
HAC
1C-304
STORAGE
1C-306
STAIR #8-1
STAIR-1
TE
1C-316
LIFT-2
7-2
LIFT (FUTURE)
ELEV.-2
S-8-2
ELEV.-2
S-7-2
DISPOSAL LINEN
CHUTE
1C-312A
(F.) TLT.
1C-297SOCIAL WORKER
1C-257
ROOM
1C-255
OFFICE
1C-253B
CHECK IN ROOM
1C-253
GROUP THERAPY
ROOM
1C-253A
PSYCH. OFFICE
1C-272
PSYCH. OFFICE
1C-276
NURSE
1C-274
OFFICE
1C-271
PSYCH. OFFICE
1C-273
CORR.
1C-272
ELEC.
1C-109
OFFICE
1C-114
F. TLT
1C-107
BEAUTY SHOP
1C-232
PSYCHOLOGIST
OFFICE
1C-262CANTEEN STORAGE
1C-241B
OFFICE
1C-241A
FOOD STOR. AREA
1C-241 CLINICAL
PHARMACIST
1C-260
WALK-IN FREEZER
1C-243A
WALK-IN
REFRIGERATOR
1C-243
SOCIAL WORKER
1C-258
PA
1C-256
PSYCHIATRIC
1C-252
RECPT. CLERK
1C-251
TR
1C-140
OFFICE
1C-144
OFFICE
1C-142
CUBICLES
1C-130
O.T. R.M.S. THERAPY
1C-350C
SOCIALWORKER
1C-293
PSYCHIATRIC
1C-283
M. TLT
1C-105
EXAM. ROOM
1C-285
NURSE
1C-287
NURSE
1C-289
PSYCH. OFFICE
1C-291
PSYCHOLOGIST
1C-350E
PRRC COORD.
1C-350A
(M.) TLT.
1C-295
SOILED SERVICE
LOBBY
1C-312
ELEV.-2
S-6-2
ELECTRICAL
1C-326
EQUIPMENT
CALIBRATION
ROOM/COMPUTER
1C-211
CONTROL ROOM
1C-205
ULTRA SOUND
1C-203
RETAIL STORE AREA
1C-223
STAFF DINING ROOM
1C-342
F. TLT. / SHOWER
1C-344A
M. TLT. / SHOWER
1C-346A
MECHANICAL
1C-314
TLT.
1C-332
TLT.
1C-324
PA
1C-254
PHYSICIANS VIEWING
ROOM
1C-213
PSYCHOSOCIAL
RELIABILITITION
1C-350
SOCIAL WORKER
1C-350D
NURSE
1C-353
PSYCHIATRIC
1C-348
MALE LOCKERS
1C-346
FEMALE LOCKERS
1C-344
ELEVATOR LOBBY
1C-C7
CORR.
1C-C8
SOTOPIC STOR. PREP.
ROOM
1C-209
ULTRA-SOUND
1B-150
DISPLAY
1C-221A
Room
1A-331B
DINING AREA
1C-220
FOOD SERVICE AREA
1C-233
CORR.
1C-C6
WAITING
1C-250 CORR.
1C-250
CORR.
1C-240
KITCHEN
1C-240
PRRC STAFF
1C-350B
CORR.
1C-270
CORR.
1C-C10
VENDOR
1C-222
SEATING
1C-222A
CORR.
1C-C1
PSYCHIATRIC
1C-281
STAIR #9
STAIR
WAITING
1C-280
VENDING MACHINES
1C-221
CORRIDOR
1C-C1
PSYCH. OFFICE
1C-275
SOCIAL WORKER
OFFICE
1C-292
HAC.
1C-242
B01-FP101E
B01-FP101E
E E E
FACP FAPS
H
19.6 19.8
H
19.6 19.8
TE
1C-316
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
102 3rd Avenue, NE PO Box 1629, Hickory, NC 28603 T: 828.315.9962 F: 828.315.9964 www.atriaxgroup.com
KEYPLAN
PLAN NORTH
AREA E
03/31/23
B
IM
/2
V
A W e s t
P a lm B e a c h
E H
R M
I n fr a s tr u c tu re U p g ra d e s D e s ig n /5
-7
.B
.M T
R
.r v t
/3
/2
:3
:2
A
M
B01-FP101E
FIRST LEVEL FLOOR PLAN - AREA
E - FIRE PROTECTION
ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM)
INFRASTRUCTURE UPGRADES
WEST PALM BEACH, FL
548-22-700
B01
03/31/23 JWB NLC
1/16" = 1'-0"1
FIRST LEVEL FLOOR PLAN - AREA E - FIRE PROTECTION
1/4" = 1'-0"2
FIRST LEVEL FLOOR PLAN - TELE. - DEMOLITION - FIRE PROTECTION
1/4" = 1'-0"3
FIRST LEVEL FLOOR PLAN - TE 1C-316 - NEW - FIRE PROTECTION
A. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
B. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN DASHED, EXISTING
MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER PLANS, NEW
MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.
C. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL
PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.
D. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO
PERFORM THIS WORK.
GENERAL NOTES:
SHEET NOTES:
1. DEMOLISH EXISTING SPRINKLER HEAD AND PIPING BACK TO ROOM PERIMETER. REFER TO NEW PLAN FOR
ADDITIONAL INFORMATION.
2. PROVIDE NEW SPRINKLER(S) IN TR ROOM PER NFPA 13 REQUIREMENTS. NO SPRINKLER PIPING OR SPRINKLERS TO BE LOCATED OVER THE TOP ON NEW EQUIPMENT RACKS. PROVIDE STANDARD RESPONSE
HEADS WITH FUSIBLE LINKS AND PROTECTIVE WIRE CAGES.
3. REMOVE ANY EXISTING FIRE ALARM NOTIFICATION OR DETECTION DEVICES WITHIN ROOM UNLESS OTHERWISE INDICATED. MODIFY ANY EXISTING FIRE ALARM CIRCUITS TO MAINTAIN EXISTING FUNCTION.
4. EXTEND EXISTING FIRE ALARM SYSTEM CIRCUIT UTILIZING 3/4" C. AND WIRING AS REQUIRED BY
MANUFACTURER'S REQUIREMENTS.
5 5 10 15 20 25 30 35 40 45
1/16" = 1'-0"
FEETSCALE
2 2 4 6 8 10
1/4" = 1'-0"
FEETSCALE
2 2 4 6 8 10
1/4" = 1'-0"
C8
C
B
A8
A6
A
19 19.619.8 20.821.2 22 23 24 25 26 27
ELEV. (FUTURE)-1
P-7-1
ELEV.-2
P-8-2
ELEV.-2
P-10-2
ELEV.-2
P-9-2
TELE ROOM
1C-124
HAC
1C-122
CORR.
1C-121
FPF ASSISTANT
1C-126
THCH OFFICE
1C-206
ROOM
1C-222B
OFFICE
1C-271
PSYCH. OFFICE
1C-273
M. TLT.
1C-121B
F. TLT.
1C-121A
OFFICE
1C-112
ELEC.
1C-109
OFFICE
1C-114
F. TLT
1C-107
OFFICE
1C-116
BEAUTY SHOP
1C-232
RECPT. CLERK
1C-251
OFFICE
1C-138
UPS ELEC. RM.
1C-136
TR
1C-140
F. TLT
1C-134
OFFICE
1C-144
M. TLT
1C-132
OFFICE
1C-142
CUBICLES
1C-130
OFFICE
1C-135C
OFFICE
1C-135F
ELEC.
1C-133
CLOSET
1C-135
PSYCHIATRIST
1C-135G
SUPV. OFFICE
1C-135H
SACRIST
1E-115C
COMMUNITY CARE
OFFICE
1C-131
UPSTAIR
STAIR
H.A.C.
1C-139
CORR.
1C-C3
OFFICE
1C-135B
M. TLT
1C-105
CATHOLIC CHAPLAIN
1E-118
CHIEF CHAPLAIN
SERVICES
1E-117
CHAPLAIN
1E-119
CHAPLAIN
1E-117
PSYCHIATRIST
1C-135E
OFFICE
1C-135D
ULTRA SOUND
1C-203
EUCHARIST
1E-114
ULTRA-SOUND
1B-150
DISPLAY
1C-221A
VOCATIONAL
REHABILITATION
CORRIDOR
1C-111
ADMIN.
1C-111
CORR.
1C-C3
CHANCEL
1E-115A
SECRETARY
1C-102
CORRIDOR
1C-101
CORRIDOR
1E-113
VEST.
C1-103
DECEDENT AFFAIRS
PATIENT SVC.
1G-122
ALCOVE
CI-104
FOOD SERVICE AREA
1C-233
WAITING
1C-250 CORR.
1C-250VENDOR
1C-222
OFFICE
1C-113
OFFICE
1C-115
OFFICE
1C-116A
SEATING
1C-222A
OFFICE
1C-135A
CORR.
1C-C1
NURSE
1C-146
STAIR #9
STAIR
WAITING
1C-280
VENDING MACHINES
1C-221
CORRIDOR
1C-C1
NAVE
1E-115
CHAPLAIN
1E-116
PSYCH. OFFICE
1C-275
B01-FP101F
B01-FP101F
C
C
TR
1C-140
UPS ELEC. RM.
1C-136
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
102 3rd Avenue, NE PO Box 1629, Hickory, NC 28603 T: 828.315.9962 F: 828.315.9964 www.atriaxgroup.com
KEYPLAN
PLAN NORTH
AREA F
03/31/23
B
IM
/2
V
A W e s t
P a lm B e a c h
E H
R M
I n fr a s tr u c tu re U p g ra d e s D e s ig n /5
-7
.B
.M T
R
.r v t
/3
/2
:3
:3
A
M
B01-FP101F
FIRST LEVEL FLOOR PLAN - AREA
F - FIRE PROTECTION
ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM)
INFRASTRUCTURE UPGRADES
WEST PALM BEACH, FL
548-22-700
B01
03/31/23 JWB NLC
1/16" = 1'-0"1
FIRST LEVEL FLOOR PLAN - AREA F - FIRE PROTECTION
1/4" = 1'-0"2
FIRST LEVEL FLOOR PLAN - NURSE - DEMOLITION - FIRE PROTECTION
1/4" = 1'-0"3
FIRST LEVEL FLOOR PLAN - TR 1C-140 - NEW - FIRE PROTECTION
A. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
B. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN DASHED, EXISTING
MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER PLANS, NEW
MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.
C. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL
PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.
D. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO
PERFORM THIS WORK.
GENERAL NOTES:
SHEET NOTES:
1. DEMOLISH EXISTING SPRINKLER HEAD AND PIPING BACK TO ROOM PERIMETER. REFER TO NEW PLAN FOR
ADDITIONAL INFORMATION.
2. PROVIDE NEW SPRINKLER(S) IN TR ROOM PER NFPA 13 REQUIREMENTS. NO SPRINKLER PIPING OR SPRINKLERS TO BE LOCATED OVER THE TOP ON NEW EQUIPMENT RACKS. PROVIDE STANDARD RESPONSE
HEADS WITH FUSIBLE LINKS AND PROTECTIVE WIRE CAGES.
3. REMOVE ANY EXISTING FIRE ALARM NOTIFICATION OR DETECTION DEVICES WITHIN ROOM UNLESS OTHERWISE INDICATED. MODIFY ANY EXISTING FIRE ALARM CIRCUITS TO MAINTAIN EXISTING FUNCTION.
4. EXTEND EXISTING FIRE ALARM SYSTEM CIRCUIT UTILIZING 3/4" C. AND WIRING AS REQUIRED BY
MANUFACTURER'S REQUIREMENTS.
5 5 10 15 20 25 30 35 40 45
1/16" = 1'-0"
FEETSCALE
2 2 4 6 8 10
1/4" = 1'-0"
FEETSCALE
2 2 4 6 8 10
1/4" = 1'-0"
G8
G
E
D
C8
C
B
A8
A6
A
H4
1 2 3 4 5 6 7 8 9 9.2 9.8 10.4 11.2 11.812.2 13 14 15 16 17 1818.2 19 19.619.8 20.821.2 22 23 24 25 26 27
AREA A
AREA B
AREA C
AREA D
AREA E
AREA F
G.8
9.8
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
102 3rd Avenue, NE PO Box 1629, Hickory, NC 28603 T: 828.315.9962 F: 828.315.9964 www.atriaxgroup.com 03/31/23
B
IM
/2
V
A W e s t
P a lm B e a c h
E H
R M
I n fr a s tr u c tu re U p g ra d e s D e s ig n /5
-7
.B
.M T
R
.r v t
/3
/2
:3
:3
A
M
B01-FP102
SECOND LEVEL FLOOR PLAN -
FIRE PROTECTION
ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM)
INFRASTRUCTURE UPGRADES
WEST PALM BEACH, FL
548-22-700
B01
03/31/23 JWB NLC
1" = 20'-0"1
SECOND LEVEL FLOOR PLAN - OVERALL - FIRE PROTECTION
PLAN NORTH
20 20 40
1" = 20'-0"
G8
G
E
D
C8
C
H4
1 2 3 4 5 6 7 8 9 9.2 9.8
STAIRWELL
ENCLOSURE
STAIR
STAIR #4-1
STAIR-1
ROOM
2A-304
STORAGE ROOM
2A-305
HAC
2A-302
ROOM
2A-303
MECHANICAL
2A-306
STAFF TLT.
2A-323
MED RM.
2A-321A
STAFF
2A-325
SOILED UTILITY
2A-326
CLEAN UTILITY
2A-327
ELECT. ROOM
2A-328
O.R. NURSE
MANAGER
2A-332
TRASH
2A-330
RECOVERY ROOM
ISOLATION BDRM
2A-329A
ANTE ROOM
2A-329
GAS STORAGE
2A-334
STAIR 5
STAIR
ELECT.
2B-302B
TEL.
2B-302C
OFFICE
2A-118
OFFICE
2A-114
OFFICE CLERICAL
2A-119
EQUIPMENT AND
APPARATUS
STORAGE
2A-236
CYSTOSCOPY ROOM
2A-238
EXTERNAL
RADIOGRAPHIC
CONTROL
2A-238B
INSTRUMENT PREP.
AND STERILIZATION
2A-238A
CYSTOSCOPY ROOM
2A-242
IMPLANT STORAGE
ROOM
2A-212
FROZEN SECT LAB
2A-229
DICT. CUBIC.
2A-227B
PHYS/STAFF LOUNGE
2A-227
MED. ROOM
2A-225A
ANASTHESIA
2A-225
SOILED HOLDING
AREA
2A-223
ROOM
2A-221
O.R. #5
2A-211
O.R. #4
2A-209
TELEPHONE/SWITCH
GEAR
2A-310
O.R. #6
2A-213
MALE LOCKERS
2A-246
SUB STERILE ROOM
2A-213A
UB STERILE
2A-207A
CORRIDOR
2A-C4
CONTROL
STATION/CRT
2A-258
CORRIDOR
2A-227A
FINE INSTRUMENT
PREP. AND STOR.
2A-210
FEMALE LOCKERS
2A-244
F. TOILET/SHOWERS
2A-244A
RECOVERY ROOM
2A-320
RECOV RM NURSE
STATION
2A-321
SOILED LINEN CHUTE
2B-302A
SOILED SERVICE
LOBBY
2B-302
PATIENT TOILET
2A-205
CORRIDOR
2A-C7
BREAK RM
2A-279
ANESTHESIA
2A-278
NURSES ST.
2A-280
PATIENT TLT
2A-276
CLEAN
2A-274
PATIENT TLT
2A-277
MED
2A-269
SOIL
2A-275
ROOM
2A-272
CORRIDOR-2
2A-C3-2
BLANKETS
2A-271
CORRIDOR
2A-C1
NOURISHMENT
2A-273
PATIENT TLT
2A-266
TR
2A-281
CORRIDOR-2
2A-C7-2
PRE-OP
2A-C6
ANTE RM
2A-282
CLINICAL
COORDINATOR
2A-116
ATRIUM
B01-FP102A
B01-FP102A
G.8
9.8
TR
2A-281
1 13
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
102 3rd Avenue, NE PO Box 1629, Hickory, NC 28603 T: 828.315.9962 F: 828.315.9964 www.atriaxgroup.com
KEYPLAN
PLAN NORTH
AREA A
03/31/23
B
IM
/2
V
A W e s t
P a lm B e a c h
E H
R M
I n fr a s tr u c tu re U p g ra d e s D e s ig n /5
-7
.B
.M T
R
.r v t
/3
/2
:3
:4
A
M
B01-FP102A
SECOND LEVEL FLOOR PLAN -
AREA A - FIRE PROTECTION
ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM)
INFRASTRUCTURE UPGRADES
WEST PALM BEACH, FL
548-22-700
B01
03/31/23 JWB NLC
1/16" = 1'-0"1
SECOND LEVEL FLOOR PLAN - AREA A - FIRE PROTECTION
1/4" = 1'-0"3
SECOND LEVEL FLOOR PLAN -TR 2A-281 - NEW - FIRE PROTECTION
1/4" = 1'-0"2
SECOND LEVEL FLOOR PLAN -ANESTH. - DEMOLITION - FIRE PROTECTION
A. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
B. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN DASHED, EXISTING
MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER PLANS, NEW
MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.
C. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL
PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.
D. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO
PERFORM THIS WORK.
GENERAL NOTES:
SHEET NOTES:
1. DEMOLISH EXISTING SPRINKLER HEAD AND PIPING BACK TO ROOM PERIMETER. REFER TO NEW PLAN FOR
ADDITIONAL INFORMATION.
2. PROVIDE NEW SPRINKLER(S) IN TR ROOM PER NFPA 13 REQUIREMENTS. NO SPRINKLER PIPING OR SPRINKLERS TO BE LOCATED OVER THE TOP ON NEW EQUIPMENT RACKS. PROVIDE STANDARD RESPONSE
HEADS WITH FUSIBLE LINKS AND PROTECTIVE WIRE CAGES.
3. REMOVE ANY EXISTING FIRE ALARM NOTIFICATION OR DETECTION DEVICES WITHIN ROOM UNLESS OTHERWISE INDICATED. MODIFY ANY EXISTING FIRE ALARM CIRCUITS TO MAINTAIN EXISTING FUNCTION.
4. EXTEND EXISTING FIRE ALARM SYSTEM CIRCUIT UTILIZING 3/4" C. AND WIRING AS REQUIRED BY
MANUFACTURER'S REQUIREMENTS.
5 5 10 15 20 25 30 35 40 45
1/16" = 1'-0"
FEETSCALE
2 2 4 6 8 10
1/4" = 1'-0"
FEETSCALE
2 2 4 6 8 10
1/4" = 1'-0"
F
J
H
G8
G
E
D
C8
C
H4
9.8 10.4 11.2 11.812.2 13 14 15 16 17 1818.2
ELEV.-3
P-6-3
ELEV.-3
S-5-3
ELEV.-3
S-4-3
ELEV.-3
S-3-3
ELEV.-3
S-2-3
ELEV.-3
S-1-3
UPS ELEC. RM.
2B-304C
MECH.
2B-304D
ELEV.-3
P-1-3
TEL.
2B-302C
UPS ELEC. RM.-2
2B-304C-2 CLEAN SERVICE
2B-304 PATIEN SERVICE
LOBBY
2B-306
FEMALE TOILET
2B-312A
MECHANICAL
2A-304A
FEMALE
LOCKER/LOUNGE
2B-312
ROOM #1
2B-326
ROOM #2
2B-328
ROOM #3
2B-330