ATTACHMENT 17 - Telecom 2 of 6.pdf

PDF 9 MB Posted

Attached to
Y1AZ--EHRM Infrastructure Upgrades Construction West Palm Beach Federal contract opportunity
Solicitation number
36C77623B0045
Issued by
Department of Veterans Affairs Technology Acquisition Center Austin

About this file

This document provides plans and specifications for an electronic health record modernization infrastructure upgrade construction project at the Department of Veterans Affairs West Palm Beach facility. The project involves upgrading telecommunications infrastructure including installing new fiber optic backbone cabling, conduits, pathway systems, and telecommunications rooms. Plans show existing conditions and detailed drawings of each level with networking diagrams, equipment locations, and technical specifications. The solicitation number is listed as 36C77623B0045 for the construction work. The estimated period of performance and response deadline are not specified.

View the file

Other files for this federal contract opportunity

Other files attached to Y1AZ--EHRM Infrastructure Upgrades Construction West Palm Beach, newest first.
File Type Posted
36C77623B0045 0003.pdf PDF
Clarifications to Technical Questions 9-5-23.pdf PDF
Cart Lift Motor Photos.pdf PDF
Updated Drawings for Clarifications.pdf PDF
36C77623B0045 0002.pdf PDF
Map of Wells Question 66.pdf PDF
Technical Questions - FINAL - West Palm Beach 8-21-23.pdf PDF
Photos for Responses to Questions 124 and 127.pdf PDF
Site Visit Sign-in Sheet - West Palm Beach 7-19-23.pdf PDF
36C77623B0045 0001.pdf PDF
ATTACHMENT 24 - Construction Wage Rates - Palm Beach 7-7-23.pdf PDF
ATTACHMENT 4 - Civil 1 of 5.pdf PDF
ATTACHMENT 5 - Civil 2 of 5.pdf PDF
ATTACHMENT 16 - Telecom 1 of 6.pdf PDF
ATTACHMENT 18 - Telecom 3 of 6.pdf PDF
ATTACHMENT 19 - Telecom 4 of 6.pdf PDF
ATTACHMENT 23 - Limitations on Subcontracting - Construction.docx DOCX document
ATTACHMENT 24 - Construction Wage Rates - Palm Beach 3-24-23.pdf PDF
ATTACHMENT 7 - Civil 4 of 5.pdf PDF
ATTACHMENT 10 - Fire Protection.pdf PDF
ATTACHMENT 22 - Contractor Core Work Hours.pdf PDF
ATTACHMENT 26 - Site Visit Instructions.pdf PDF
36C77623B0045 - 7-6-23.pdf PDF
ATTACHMENT 6 - Civil 3 of 5.pdf PDF
ATTACHMENT 11 - Mechanical 1 of 2.pdf PDF
ATTACHMENT 14 - Security.pdf PDF
ATTACHMENT 15 - Structural.pdf PDF
ATTACHMENT 21 - Telecom 6 of 6.pdf PDF
ATTACHMENT 25 - Contractor Safety - Environmental Form.docx DOCX document
ATTACHMENT 1 - Specifications.pdf PDF
ATTACHMENT 2 - General.pdf PDF
ATTACHMENT 8 - Civil 5 of 5.pdf PDF
ATTACHMENT 9 - Electrical.pdf PDF
ATTACHMENT 12 - Mechanical 2 of 2.pdf PDF
ATTACHMENT 13 - Plumbing.pdf PDF
ATTACHMENT 20 - Telecom 5 of 6.pdf PDF
ATTACHMENT 3 - Architectural.pdf PDF
Show all 37

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

JJ

HH

G8G8

GG

FF

EE

DD

C8C8

CC

BB

A8A8

8 9

9 9.2

9.2 9.8

9.8 10.4

10.4

11.2

11.2 11.8

11.8

12.2

12.2

1818.2

18.2

19.6

19.6

19.8

19.8

20.8

20.821.2

21.2 22

A6A6

AA

H4H4

TR 1-3A-320

TR 1-3B-139A

4"x4"

4"x4"

4"x4"

4"x4"

4"x4"

4"x4"

4"x4"

4"x4"

4"x4"

4"x4"

4"x4"

4"x4"

"x

"x

"x

"x

"x

"x

"x

"x

"x

"x

"x

"x

"x

"x

4"x4"

4"x4"

4"x4"

4"x4"

4"x4"

4"x4"

4"x4"

4"x4"

4"x4"

4"x4" 4"x4"

4"x4"

4"x4"

4"x4"

4"x4"

4"x4"

4"x4"

4"x4"

4"x4"

4"x4"

4"x4"

4"x4"

"x

"x

"x

"x

"x

"x

4"x4"

4"x4"

6 7

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

6 South Old Orchard Ave, Saint Louis, MO 63119 T: 800.404.7677 www.introba.com

B

IM

/2

V

A W e s t P a lm

B e a c h

E H

R M

I n fr a s tr u c tu re U p g ra d e s D e s ig n /5

-7

.B

.T

R

.r v t

/2

/2

:2

:5

A

M

B01-TN135

THIRD INT LEVEL OVERALL PLAN -

TELECOM

ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM)

INFRASTRUCTURE UPGRADES

WEST PALM BEACH, FL

548-22-700

03/31/23 PR TL

B01

1" = 20'-0"1

THIRD INT LEVEL OVERALL PLAN - TELECOM

1. PROVIDE (2) 4" CONDUITS FROM THIRD LEVEL TO

RISER ROOM ON LEVEL ABOVE FOR B-SIDE VERTICAL

BACKBONE CABLING.

2. PROVIDE (2) 4" CONDUITS FROM THIRD LEVEL TO

RISER ROOM ON LEVEL ABOVE FOR A-SIDE VERTICAL

BACKBONE CABLING.

3. EXISTING INTERSTITIAL CABLE TRAY

4. PROVIDE (1) 2" CONDUIT FROM RISER ROOM TO

EXISTING INTERSTITIAL CABLE TRAY FOR A-SIDE

BACKBONE PATHWAY.

5. PROVIDE (1) 2" CONDUIT FROM RISER ROOM TO

EXISTING INTERSTITIAL CABLE TRAY FOR B-SIDE

BACKBONE PATHWAY.

6. PROVIDE (1) 2" CONDUIT FROM EXISTING INTERSTITIAL

CABLE TRAY TO TR ON LEVEL BELOW FOR A-SIDE

BACKBONE PATHWAY.

7. PROVIDE (1) 2" CONDUIT FROM EXISTING INTERSTITIAL

CABLE TRAY TO TR ON LEVEL BELOW FOR B-SIDE

BACKBONE PATHWAY.

KEYED NOTES:#

PLAN NORTH

20 20 40

1" = 20'-0"

FEETSCALE

GENERAL NOTES:

1. CONTRACTOR SHALL COORDINATE THE EQUIPMENT'S

INSTALLATION AND FINAL LOCATION WITH THE ELECTRICAL

AND MECHANICAL DIVISION. REFER TO ELECTRICAL,

MECHANICAL AND PLUMBING DRAWINGS.

2. CONTRACTOR SHALL INSTALL PATHWAY DIVIDERS, RADIUS

DROP, AND ANY OTHER FITTING FOR A PROPER CABLE

RUNWAY INSTALLATION.

3. CONTRACTOR SHALL COORDINATE THE HILTI SPEED

SLEEVE LOCATIONS WITH THE PATHWAY SYSTEM LAYOUT

OUTSIDE EACH TELECOM ROOM. REFER TO FLOOR PLAN

DRAWINGS.

4. CONTRACTOR SHALL INSTALL BACKBONE RISER SLEEVES

AND CONDUITS OF THE SIZE AS INDICATED ON THE PLANS.

REFER TO SECTION 27 10 00 STRUCTURED CABLING AND

SECTION 27 05 33 CONDUITS AND BOXES FOR

COMMUNICATIONS SYSTEMS.

5. CONTRACTOR SHALL X-RAY CONCRETE FLOOR BEFORE

CORE DRILLING. CONTRACTOR SHALL COORDINATE WITH

THE COR BEFORE BEGINNING DRILLING.

6. CONTRACTOR SHALL FIRESTOP RISER SLEEVES AND EMPTY

SPARE RISER SLEEVES. REFER TO SECTION 07 84 00

FIRESTOPPING.

7. GOVERNMENT EQUIPMENT WILL BE RELOCATED BY

GOVERNMENT IT PERSONNEL. CONTRACTOR WILL HAVE

TECHNICIANS AVAILABLE TO PROVIDE SUPPORT DURING

OUTAGES AND CUT-OVERS. COORDINATE WORK WITH

THE COR.

8. CONTRACTOR SHALL PROVIDE MTP, FIBER OPTIC TRUNK

CABLES FOR SIDE A AND SIDE B BACKBONE FROM THE

DATA CENTER TO EACH TELECOMMUNICATIONS ROOM.

COORDINATE WITH COR.

9. CONTRACTOR SHALL PROVIDE FIBER OPTIC PATCH

CABLES FOR SIDE A AND SIDE B FROM THE FIBER OPTIC

DISTRIBUTOR TO EQUIPMENT CABINETS. COORDINATE

WITH COR.

10. CONTRACTOR SHALL VERIFY FIBER OPTIC CABLES

MEASUREMENTS PRIOR TO ORDERING. COORDINATE WITH

COR.

11. PATHWAY SHOWN IN HALFTONE IS EXISTING AND SHALL

REMAIN IN PLACE. ROUTE NEW FIBER OPTIC BACKBONE

CABLING THROUGH EXISTING INFRASTRUCTURE AS

NOTED.

Revisions: Date:

G8G8

GG

FF

EE

DD

C8C8

CC

BB

A8A8

8 9

9 9.2

9.2 9.8

9.8 10.4

10.4

11.2

11.2 11.8

11.8

12.2

12.2

1818.2

18.2

19.6

19.6

19.8

19.8

20.8

20.821.2

21.2 22

A6A6

AA

H4H4

B01-TN315

B01-TN316

B01-TN317

TR 1-4A-324

TR 1-4B-252

TR 1-4C-234

AREA A

AREA B

AREA C

AREA D

AREA E

AREA F

ROUTE CABLING TO

TELECOM ROOM

TR 1-4A-324

ROUTE CABLING TO

TELECOM ROOM

TR 1-4B-252

ROUTE CABLING TO

TELECOM ROOM

TR 1-4C-234

(2) SS24

(4) SS44

(4) SS44

12"x4"

18"x4"

12"x4"

"x

18"x4"18"x4"

18"x4"

(4) SS44

"x

18"x4" 18"x4"

"x

"x

18"x4"

(4) SS44

(4) SS44

(4) SS44

(4) SS44

(4) SS44

18"x4"

"x

18"x4" 18"x4"(4) SS44

18"x4"

(4) SS44

"x

18"x4"

(4) SS44

(4) SS44

"x

4"

"x

4"

18"x4"

12"x4"

(2) SS24

18"x4"

"x

"x

(4) SS44

18"x4"(4) SS44

18"x4"18"x4"

"x

"x

(4) SS44

(4) SS44

(4) SS44

"x

(4) SS44

(4) SS44

(4) SS44

(4) SS44

(4) SS44

LEGEND

DELINIATATION LINE BETWEEN

TELECOM ROOMS. ROUTE THE CABLING

FOR ALL SYSTEMS TO THE TELECOM

ROOMS SHOWN ON THE DRAWINGS

BASED ON THIS SEPARATION LINE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

6 South Old Orchard Ave, Saint Louis, MO 63119 T: 800.404.7677 www.introba.com

B

IM

/2

V

A W e s t P a lm

B e a c h

E H

R M

I n fr a s tr u c tu re U p g ra d e s D e s ig n /5

-7

.B

.T

R

.r v t

/2

/2

:1

:2

A

M

B01-TN140

FOURTH LEVEL OVERALL PLAN -

TELECOM

ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM)

INFRASTRUCTURE UPGRADES

WEST PALM BEACH, FL

548-22-700

03/31/23 PR TL

B01

1" = 20'-0"1

FOURTH LEVEL OVERALL PLAN - TELECOM

PLAN NORTH

20 20 40

1" = 20'-0"

FEETSCALE

1. PROVIDE (2) 4" CONDUITS FROM THIRD LEVEL FOR B-

SIDE VERTICAL BACKBONE CABLING.

2. PROVIDE (2) 4" CONDUITS FROM THIRD LEVEL FOR A-

SIDE VERTICAL BACKBONE CABLING.

3. PROVIDE (2) 4" CONDUITS FROM FOURTH LEVEL TO

RISER ROOM TO TR 1-5A-235 ON LEVEL ABOVE FOR B-

SIDE VERTICAL BACKBONE CABLING.

4. PROVIDE (2) 4" CONDUITS FROM FOURTH LEVEL

RISER ROOM TO TR 1-5B-234 ON LEVEL ABOVE FOR A-

SIDE VERTICAL BACKBONE CABLING.

KEYED NOTES:#

GENERAL NOTES:

1. CONTRACTOR SHALL COORDINATE THE EQUIPMENT'S

INSTALLATION AND FINAL LOCATION WITH THE ELECTRICAL

AND MECHANICAL DIVISION. REFER TO ELECTRICAL,

MECHANICAL AND PLUMBING DRAWINGS.

2. CONTRACTOR SHALL INSTALL PATHWAY DIVIDERS, RADIUS

DROP, AND ANY OTHER FITTING FOR A PROPER CABLE

RUNWAY INSTALLATION.

3. CONTRACTOR SHALL COORDINATE THE HILTI SPEED

SLEEVE LOCATIONS WITH THE PATHWAY SYSTEM LAYOUT

OUTSIDE EACH TELECOM ROOM. REFER TO FLOOR PLAN

DRAWINGS.

4. CONTRACTOR SHALL INSTALL BACKBONE RISER SLEEVES

AND CONDUITS OF THE SIZE AS INDICATED ON THE PLANS.

REFER TO SECTION 27 10 00 STRUCTURED CABLING AND

SECTION 27 05 33 CONDUITS AND BOXES FOR

COMMUNICATIONS SYSTEMS.

5. CONTRACTOR SHALL X-RAY CONCRETE FLOOR BEFORE

CORE DRILLING. CONTRACTOR SHALL COORDINATE WITH

THE COR BEFORE BEGINNING DRILLING.

6. CONTRACTOR SHALL FIRESTOP RISER SLEEVES AND EMPTY

SPARE RISER SLEEVES. REFER TO SECTION 07 84 00

FIRESTOPPING.

7. GOVERNMENT EQUIPMENT WILL BE RELOCATED BY

GOVERNMENT IT PERSONNEL. CONTRACTOR WILL HAVE

TECHNICIANS AVAILABLE TO PROVIDE SUPPORT DURING

OUTAGES AND CUT-OVERS. COORDINATE WORK WITH

THE COR.

8. CONTRACTOR SHALL PROVIDE MTP, FIBER OPTIC TRUNK

CABLES FOR SIDE A AND SIDE B BACKBONE FROM THE

DATA CENTER TO EACH TELECOMMUNICATIONS ROOM.

COORDINATE WITH COR.

9. CONTRACTOR SHALL PROVIDE FIBER OPTIC PATCH

CABLES FOR SIDE A AND SIDE B FROM THE FIBER OPTIC

DISTRIBUTOR TO EQUIPMENT CABINETS. COORDINATE

WITH COR.

10. CONTRACTOR SHALL VERIFY FIBER OPTIC CABLES

MEASUREMENTS PRIOR TO ORDERING. COORDINATE WITH

COR.

11. PATHWAY SHOWN IN HALFTONE IS EXISTING AND SHALL

REMAIN IN PLACE. ROUTE NEW FIBER OPTIC BACKBONE

CABLING THROUGH EXISTING INFRASTRUCTURE AS

G8G8

GG

FF

EE

DD

C8C8

8 9

9 9.2

9.2 9.8

9.82

H4H4

4 2

3 4

4 4

3 3

1 4

GW

GW

GW

GW

GW

GW

GWCAM

GENERAL LABORATORY

4A-201

CONFERENCE

4A-130

COMPUTER ROOM

4A-132

HEMATOLOGY

4A-134

MICROBIOLOGY ADP SYSTEM

4A-136

BIOSAFETY LAB

4A-136A

ROOM

4A-136B

STER AND SOLUTION PREP

4A-136C

CLOSET

4A-136D

OFFICE

4A-138

FLAM. TOXIC STORAGE

4A-140A

BULK STORAGE

4A-140

CORR.

4A-C2

HEMATOLOGY

4A-203

OFFICE

4A-203A

SPECIMEN ACCESIONING

4A-205

BLOOD BANK

4A-207

FEMALE LOCKERS

4A-209

FEM. TLT.

4A-209A

MALE LOCKERS

4A-216

MALE TLT.

4A-216A

EMPLOYEE BIOSAFETY

4A-214

HAC

4A-212

TELE/SWITCH ROOM

4A-225

DUMBWAITER

4A-223

F.D. WALK-IN COLDROOM

4A-210

ELECT ROOM

4A-221

STAIR #4

STAIR

CORRIDOR

4A-C7

STOCK ROOM

4A-302

HISTOLOGY

4A-304

CYTOLOGY

4A-304A

SOILED & BLOCK FILES

4A-304B

FROZEN/GROSS SECTION

4A-306

AUTOPSY ROOM

4A-312 HAC

4A-313

MORTUARY REFRIGERATOR

4A-314

CORR.

4A-C8

LOCKERS

4A-311

TOILET

4A-311A

GROSS SPECIMEN STORAGE

4A-316

MECHANICAL

4B-304B

TR

4A-324

HAC

4A-326

STORAGE

4A-328 STAIR #5

STAIR

SOILED SERVICE LOBBY

4B-302

UPS ELEC. RM.

4B-304C

ELEV.

S-4

ELEV.

S-5

SOILED LINEN CHUTE

4B-302A

ELECT.

4B-302B

TEL.

4B-302C

MALE

4B-200

ROOM

4A-211

B01-TN315

MECH.

4B-304D

KEY PLAN

AREA A

PLAN NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

6 South Old Orchard Ave, Saint Louis, MO 63119 T: 800.404.7677 www.introba.com

B

IM

/2

V

A W e s t P a lm

B e a c h

E H

R M

I n fr a s tr u c tu re U p g ra d e s D e s ig n /5

-7

.B

.T

R

.r v t

/2

/2

:1

:3

A

M

B01-TN140A

FOURTH LEVEL FLOOR PLAN -

AREA A - TELECOM

ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM)

INFRASTRUCTURE UPGRADES

WEST PALM BEACH, FL

548-22-700

03/31/23 PR TL

B01

1/8" = 1'-0"1

FOURTH LEVEL FLOOR PLAN - AREA A - TELECOM

1. EXISTING TELECOMMUNICATIONS ROOM.

2. EXISTING CONDITIONS WERE NOT OBSERVED ON SITE

VISITS, REFER TO AS BUILTS FOR DATA DEVICE LAYOUTS.

3. DATA OUTLET RELOCATED FROM DEMOLISHED WALL IN

NEW TR.

KEYED NOTES:#

1. REFER TO SHEET T-000 FOR GENERAL NOTES AND LEGENDS.

2. CONTRACTOR SHALL INSTALL BACKBONE RISER SLEEVES AND

CONDUITS OF THE SIZE AS INDICATED ON THE PLANS. REFER

TO SECTION 27 10 00 STRUCTURED CABLING AND SECTION 27

05 33 CONDUITS AND BOXES FOR COMMUNICATIONS

SYSTEMS.

3. CONTRACTOR SHALL X-RAY CONCRETE FLOOR BEFORE CORE

DRILLING. CONTRACTOR SHALL COORDINATE WITH THE COR

BEFORE BEGINNING DRILLING.

4. CONTRACTOR SHALL FIRESTOP RISER SLEEVES AND EMPTY

SPARE RISER SLEEVES. REFER TO SECTION 07 84 00

FIRESTOPPING.

5. CONTRACTOR SHALL INSTALL AN VERTICAL LADDER TYPE

CABLE TRAY ON THE WALL ABOVE THE VERTICAL RISER

SLEEVES FOR BACKBONE CABLE SUPPORT AS INDICATED ON

THE PLANS. THE CABLE TRAY SHALL BE SECURELY

ANCHORED TO THE WALL SUFFICIENT TO SUPPORT THE

TOTAL WEIGHT OF CABLES AND CABLE TRAY PLUS 50%.

6. CONTRACTOR SHALL INSTALL CABLE SUPPORTS SUFFICIENT

TO SUPPORT COMMUNICATIONS CABLES ON THE VERTICAL

CABLE TRAY WITHOUT DAMAGING OR DEFORMING THE CABLE.

7. CONTRACTOR SHALL INSTALL NEW J-HOOKS WHERE THERE IS

NO CABLE TRAY OR COMMUNICATIONS CONDUIT UNLESS

OTHERWISE NOTED.

8. CONTRACTOR SHALL INSTALL NEW CATEGORY 6A PATCH

PANELS IN THE TELECOMMUNICATION ROOM AS INDICATED ON

RACK ELEVATIONS.

9. CONTRACTOR SHALL RE-TERMINATE AND TEST CABLING

REMOVED FROM ANY WALL MOUNT EQUIPMENT UNLESS

OTHERWISE NOTED. TESTING SHALL BE PERFORMED BY THE

CONTRACTOR DURING COMMISSIONING.

10. CONTRACTOR SHALL INSTALL NEW CATEGORY 6A

TELECOMMUNICATIONS/DATA OUTLET AS INDICATED.

EXISTING COMMUNICATION OUTLET BOXES AND CONDUITS TO

BE REUSED.

11. CONTRACTOR SHALL REPLACE ALL DATA CABLE WITH NEW

CATEGORY 6A CABLE UNLESS OTHERWISE NOTED.

12. CONTRACTOR SHALL TERMINATE COMMUNICATIONS CABLES

WITH NEW CATEGORY MODULAR JACKS TO MATCH THE

COMMUNICATION CABLE PERFORMANCE SPECIFICATIONS.

NEW MODULAR JACKS SHALL BE OF THE SAME

MANUFACTURER AS THE FACE PLATES, PATCH PANELS, AND

PATCH CABLES.

13. CONTRACTOR SHALL INSTALL NEW CATEGORY 6A CABLES

AND CONNECTIVITY COMPONENTS THAT ARE OF THE SAME

MANUFACTURER, INCLUDING CABLE, MODULAR JACKS, PATCH

PANELS, FACEPLATES, AND PATCH CABLES.

14. CONTRACTOR SHALL TEST ALL NEW AND EXISTING RE-

TERMINATED CABLES IN ACCORDANCE WITH THE

SPECIFICATION 27 05 11.

GENERAL NOTES:

5 5 10 15 20

1/8" = 1'-0"

FEETSCALE

C8C8

CC

BB

A8A8

8 9

9 9.2

9.2 9.8

9.82

A6A6

AA

4 3 4

4 1

GW

GW

GW

CAM

SEC/CLERK

4A-110

CHIEF LAB SERVICE

4A-112

STAFF PATHOLOGIST

4A-114

STAFF PATHOLOGIST

4A-116

STAFF PATHOLOGIST

4A-118

CHIEF MEDICAL TECH

4A-120

CONFERENCE

4A-130

STAIR #2

STAIR

CORR.

4A-C2

CORRIDOR

4A-C1

OFFICE

4A-203A

MALE

4B-200

KEY PLAN

AREA B

PLAN NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

6 South Old Orchard Ave, Saint Louis, MO 63119 T: 800.404.7677 www.introba.com

B

IM

/2

V

A W e s t P a lm

B e a c h

E H

R M

I n fr a s tr u c tu re U p g ra d e s D e s ig n /5

-7

.B

.T

R

.r v t

/2

/2

:1

:3

A

M

B01-TN140B

FOURTH LEVEL FLOOR PLAN -

AREA B - TELECOM

ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM)

INFRASTRUCTURE UPGRADES

WEST PALM BEACH, FL

548-22-700

03/31/23 PR TL

B01

1/8" = 1'-0"1

FOURTH LEVEL FLOOR PLAN - AREA B - TELECOM

1. EXISTING TELECOMMUNICATIONS ROOM.

2. EXISTING CONDITIONS WERE NOT OBSERVED ON SITE

VISITS, REFER TO AS BUILTS FOR DATA DEVICE LAYOUTS.

3. DATA OUTLET RELOCATED FROM DEMOLISHED WALL IN

NEW TR.

KEYED NOTES:#

1. REFER TO SHEET T-000 FOR GENERAL NOTES AND LEGENDS.

2. CONTRACTOR SHALL INSTALL BACKBONE RISER SLEEVES AND

CONDUITS OF THE SIZE AS INDICATED ON THE PLANS. REFER

TO SECTION 27 10 00 STRUCTURED CABLING AND SECTION 27

05 33 CONDUITS AND BOXES FOR COMMUNICATIONS

SYSTEMS.

3. CONTRACTOR SHALL X-RAY CONCRETE FLOOR BEFORE CORE

DRILLING. CONTRACTOR SHALL COORDINATE WITH THE COR

BEFORE BEGINNING DRILLING.

4. CONTRACTOR SHALL FIRESTOP RISER SLEEVES AND EMPTY

SPARE RISER SLEEVES. REFER TO SECTION 07 84 00

FIRESTOPPING.

5. CONTRACTOR SHALL INSTALL AN VERTICAL LADDER TYPE

CABLE TRAY ON THE WALL ABOVE THE VERTICAL RISER

SLEEVES FOR BACKBONE CABLE SUPPORT AS INDICATED ON

THE PLANS. THE CABLE TRAY SHALL BE SECURELY

ANCHORED TO THE WALL SUFFICIENT TO SUPPORT THE

TOTAL WEIGHT OF CABLES AND CABLE TRAY PLUS 50%.

6. CONTRACTOR SHALL INSTALL CABLE SUPPORTS SUFFICIENT

TO SUPPORT COMMUNICATIONS CABLES ON THE VERTICAL

CABLE TRAY WITHOUT DAMAGING OR DEFORMING THE CABLE.

7. CONTRACTOR SHALL INSTALL NEW J-HOOKS WHERE THERE IS

NO CABLE TRAY OR COMMUNICATIONS CONDUIT UNLESS

OTHERWISE NOTED.

8. CONTRACTOR SHALL INSTALL NEW CATEGORY 6A PATCH

PANELS IN THE TELECOMMUNICATION ROOM AS INDICATED ON

RACK ELEVATIONS.

9. CONTRACTOR SHALL RE-TERMINATE AND TEST CABLING

REMOVED FROM ANY WALL MOUNT EQUIPMENT UNLESS

OTHERWISE NOTED. TESTING SHALL BE PERFORMED BY THE

CONTRACTOR DURING COMMISSIONING.

10. CONTRACTOR SHALL INSTALL NEW CATEGORY 6A

TELECOMMUNICATIONS/DATA OUTLET AS INDICATED.

EXISTING COMMUNICATION OUTLET BOXES AND CONDUITS TO

BE REUSED.

11. CONTRACTOR SHALL REPLACE ALL DATA CABLE WITH NEW

CATEGORY 6A CABLE UNLESS OTHERWISE NOTED.

12. CONTRACTOR SHALL TERMINATE COMMUNICATIONS CABLES

WITH NEW CATEGORY MODULAR JACKS TO MATCH THE

COMMUNICATION CABLE PERFORMANCE SPECIFICATIONS.

NEW MODULAR JACKS SHALL BE OF THE SAME

MANUFACTURER AS THE FACE PLATES, PATCH PANELS, AND

PATCH CABLES.

13. CONTRACTOR SHALL INSTALL NEW CATEGORY 6A CABLES

AND CONNECTIVITY COMPONENTS THAT ARE OF THE SAME

MANUFACTURER, INCLUDING CABLE, MODULAR JACKS, PATCH

PANELS, FACEPLATES, AND PATCH CABLES.

14. CONTRACTOR SHALL TEST ALL NEW AND EXISTING RE-

TERMINATED CABLES IN ACCORDANCE WITH THE

SPECIFICATION 27 05 11.

GENERAL NOTES:

5 5 10 15 20

1/8" = 1'-0"

G8G8

GG

FF

EE

DD

C8C8

9.8

9.8 10.4

10.4

11.2

11.2 11.8

11.8

12.2

12.2

18 18.2

18.2

H4H4

GW

GW

4 4

GW

CAM

CAM CAM

CAM

2 3

3 3

4 1

GWGW

GW

GW

GW

GW

GW

3 3 1

1 3 1

1 4

1 3 1

4 4

1 1

4 3 4

3 1

4 4

3 4 4

2 2 4 2

3 6

MECHANICAL

4B-304A

SOILED SERVICE LOBBY

4B-302

UPS ELEC. RM.

4B-304C

ELEV.

S-4

ELEV.

S-5

ELEV.

S-1

ELEV.

S-2

ELEV.

S-3

TEL.

4B-302C

CLEAN SERVICE LOBBY

4B-304

PATIENT SERVICE LOBBY

4B-306

W.C. STRETCH

4B-312

FINAL WATER TREATMENT

4B-314

HAC

4B-316 LOCKER

4B-318STAFF

4B-318A

VISUAL INFO. SPEC.

4B-323

MEDIA CENTER

4B-325

COLOR COPY ROOM

4B-330

REPRODUCITON SPEC.

4B-331

BLACK & WHITE COPIER

4B-332

MEDICAL PHOTOGRAPHY

4B-333

STUDIO

4B-334

ADMIN

4B-321

CCTV CONTROL ROOM & STOR.

4B-324

OFFICE

4B-326

AUDIO VISUAL ROOM

4B-328

CORRIDOR

4B-329

STAIR #6

STAIR

OFFICE OF REGIONAL COUNSEL

4B-352

PARALEGAL

4B-354

ATORNEY

4B-356

OFFICE

4B-357

BMS HAC

4B-362

TRASH

4B-364

NURSE MANAGER

4B-366

CORRIDOR

4B-C2

CORRIDOR

4B-201

OFFICE

4B-200

LKRS.

4B-203

SOCIAL WORKER

4B-204

CHIEF

4B-205

DIETITIAN

4B-206

TLT.

4B-203A

SELF-DAILYSIS SUPPORT PERSONNAL

4B-211

TWO-BED DIALYSIS TRAINING

4B-212

EXAM ROOM

4B-213

PRIVATE ROOM

4B-214

PRIVATE ROOM

4B-215

STORAGE

4B-216

TREATMENT EQIUPMENT CLEAN AREA

4B-217

PRIVATE ROOM

4B-218

PRIVATE ROOM

4B-220

CLEAN UTILITY

4B-221

PRIVATE ROOM

4B-222

BIOCHEMISTRY

4B-223

W/C T.L.T.

4B-224

ELECT.

4B-225

DIALTSATE PREPARATIO ROOM

4B-236

NURSE STATION

4B-231

TREATMENT EQUIPMENT SOILED AREA

4B-235

SOILED UTILITY ROOM

4B-237

TELE SWITCH

4B-238

CORR.

4B-C4

CIRCULATION REFERENCE DESK

4B-242

NURSING TRAINING LAB

4B-240

WORKROOM/TECHNICAL SERVICES

CRT./PRINTER

4B-243

PROGRAM ASSIST.

4B-244

STORAGE

4B-245

PROGRAM ASSIST.

4B-246

PATIENT EDUCATION COORDINATOR

4B-241A

MEDIA CONFERENCE

4B-247

CONFERENCE ROOM

4B-248

TR

4B-252

CORR.

4B-251

TRAINING

4B-251A

TELE/SWITCH

4B-253

EMPLOYEE EDUCATION SERVICES

4B-252

SAFETY & HEALTH

4B-272

EMERGENCY PREPAREDNESS COORD.

4B-273

HEALTH PHYSICIST

4B-274

INDUSTRIAL HYGIENIST

4B-275

SAFETY & OCCUP. HEALTH MNGR.

4B-276SAFETY SPEC.

4B-278

CORR

4B-281

ELEC.

4B-255

LARGE CONF.

4B-283C

DINING SPACE

4B-292A

DINING AREA

4B-292B

FEM. TOIL.

4B-293A

MALE

4B-200

RESIDENT STUDY LOUNGE

4B-200A

FEMALE

4B-202

GW

B01-TN316

MECH.

4B-304D

KEY PLAN

AREA C

PLAN NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

6 South Old Orchard Ave, Saint Louis, MO 63119 T: 800.404.7677 www.introba.com

B

IM

/2

V

A W e s t P a lm

B e a c h

E H

R M

I n fr a s tr u c tu re U p g ra d e s D e s ig n /5

-7

.B

.T

R

.r v t

/2

/2

:1

:4

A

M

B01-TN140C

FOURTH LEVEL FLOOR PLAN -

AREA C - TELECOM

ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM)

INFRASTRUCTURE UPGRADES

WEST PALM BEACH, FL

548-22-700

03/31/23 PR TL

B01

1/8" = 1'-0"1

FOURTH LEVEL FLOOR PLAN - AREA C - TELECOM

1. EXISTING TELECOMMUNICATIONS ROOM.

2. EXISTING CONDITIONS WERE NOT OBSERVED ON SITE

VISITS, REFER TO AS BUILTS FOR DATA DEVICE LAYOUTS.

3. DATA OUTLET RELOCATED FROM DEMOLISHED WALL IN

NEW TR.

KEYED NOTES:#

1. REFER TO SHEET T-000 FOR GENERAL NOTES AND LEGENDS.

2. CONTRACTOR SHALL INSTALL BACKBONE RISER SLEEVES AND

CONDUITS OF THE SIZE AS INDICATED ON THE PLANS. REFER

TO SECTION 27 10 00 STRUCTURED CABLING AND SECTION 27

05 33 CONDUITS AND BOXES FOR COMMUNICATIONS

SYSTEMS.

3. CONTRACTOR SHALL X-RAY CONCRETE FLOOR BEFORE CORE

DRILLING. CONTRACTOR SHALL COORDINATE WITH THE COR

BEFORE BEGINNING DRILLING.

4. CONTRACTOR SHALL FIRESTOP RISER SLEEVES AND EMPTY

SPARE RISER SLEEVES. REFER TO SECTION 07 84 00

FIRESTOPPING.

5. CONTRACTOR SHALL INSTALL AN VERTICAL LADDER TYPE

CABLE TRAY ON THE WALL ABOVE THE VERTICAL RISER

SLEEVES FOR BACKBONE CABLE SUPPORT AS INDICATED ON

THE PLANS. THE CABLE TRAY SHALL BE SECURELY

ANCHORED TO THE WALL SUFFICIENT TO SUPPORT THE

TOTAL WEIGHT OF CABLES AND CABLE TRAY PLUS 50%.

6. CONTRACTOR SHALL INSTALL CABLE SUPPORTS SUFFICIENT

TO SUPPORT COMMUNICATIONS CABLES ON THE VERTICAL

CABLE TRAY WITHOUT DAMAGING OR DEFORMING THE CABLE.

7. CONTRACTOR SHALL INSTALL NEW J-HOOKS WHERE THERE IS

NO CABLE TRAY OR COMMUNICATIONS CONDUIT UNLESS

OTHERWISE NOTED.

8. CONTRACTOR SHALL INSTALL NEW CATEGORY 6A PATCH

PANELS IN THE TELECOMMUNICATION ROOM AS INDICATED ON

RACK ELEVATIONS.

9. CONTRACTOR SHALL RE-TERMINATE AND TEST CABLING

REMOVED FROM ANY WALL MOUNT EQUIPMENT UNLESS

OTHERWISE NOTED. TESTING SHALL BE PERFORMED BY THE

CONTRACTOR DURING COMMISSIONING.

10. CONTRACTOR SHALL INSTALL NEW CATEGORY 6A

TELECOMMUNICATIONS/DATA OUTLET AS INDICATED.

EXISTING COMMUNICATION OUTLET BOXES AND CONDUITS TO

BE REUSED.

11. CONTRACTOR SHALL REPLACE ALL DATA CABLE WITH NEW

CATEGORY 6A CABLE UNLESS OTHERWISE NOTED.

12. CONTRACTOR SHALL TERMINATE COMMUNICATIONS CABLES

WITH NEW CATEGORY MODULAR JACKS TO MATCH THE

COMMUNICATION CABLE PERFORMANCE SPECIFICATIONS.

NEW MODULAR JACKS SHALL BE OF THE SAME

MANUFACTURER AS THE FACE PLATES, PATCH PANELS, AND

PATCH CABLES.

13. CONTRACTOR SHALL INSTALL NEW CATEGORY 6A CABLES

AND CONNECTIVITY COMPONENTS THAT ARE OF THE SAME

MANUFACTURER, INCLUDING CABLE, MODULAR JACKS, PATCH

PANELS, FACEPLATES, AND PATCH CABLES.

14. CONTRACTOR SHALL TEST ALL NEW AND EXISTING RE-

TERMINATED CABLES IN ACCORDANCE WITH THE

SPECIFICATION 27 05 11.

GENERAL NOTES:

5 5 10 15 20

1/8" = 1'-0"

BB

A8A8

9.8

9.8 10.4

10.4

11.2

11.2 11.8

11.8

12.2

12.2

18 18.2

18.2

A6A6

AA

1 1 1 1

4 4

GW

CAM

CAM

GW

GW

GW

GW

GW

4 4

6 6

2 5

CORRIDOR

4A-C1

ROOM

4B-111

INTERN & RESIDENT STUDY LOUNGE

4B-112

KITCHENETTE

4B-114

CONFERENCE ROOM

4B-116

CONFERENCE ROOM

4B-117

ROOM

4B-118

ROOM

4B-119

ROOM

4B-120

EMPLOYEE ED. SERVICE

4B-121

OFFICE

4B-122 EDUCATION & DISCHARGE

4B-123

RESIDENCY PROGRAM COORDINATOR

4B-124

LMS COORD.

4B-125

CHIEF EES

4B-127

CORRIDOR

4B-C1

STAIR #10

STAIR

CORRIDOR

4B-201

OFFICE

4B-200

LKRS.

4B-203 CHIEF

4B-205

TLT.

4B-203A

TWO-BED DIALYSIS TRAINING

4B-212

EMERGENCY PREPAREDNESS COORD.

4B-273

HEALTH PHYSICIST

4B-274

MALE

4B-200

RESIDENT STUDY LOUNGE

4B-200A

FEMALE

4B-202

5 5

5 5

KEY PLAN

AREA D

PLAN NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

6 South Old Orchard Ave, Saint Louis, MO 63119 T: 800.404.7677 www.introba.com

B

IM

/2

V

A W e s t P a lm

B e a c h

E H

R M

I n fr a s tr u c tu re U p g ra d e s D e s ig n /5

-7

.B

.T

R

.r v t

/2

/2

:1

:5

A

M

B01-TN140D

FOURTH LEVEL FLOOR PLAN -

AREA D - TELECOM

ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM)

INFRASTRUCTURE UPGRADES

WEST PALM BEACH, FL

548-22-700

03/31/23 PR TL

B01

1/8" = 1'-0"1

FOURTH LEVEL FLOOR PLAN - AREA D - TELECOM

1. EXISTING TELECOMMUNICATIONS ROOM.

2. EXISTING CONDITIONS WERE NOT OBSERVED ON SITE

VISITS, REFER TO AS BUILTS FOR DATA DEVICE LAYOUTS.

3. DATA OUTLET RELOCATED FROM DEMOLISHED WALL IN

NEW TR.

KEYED NOTES:#

1. REFER TO SHEET T-000 FOR GENERAL NOTES AND LEGENDS.

2. CONTRACTOR SHALL INSTALL BACKBONE RISER SLEEVES AND

CONDUITS OF THE SIZE AS INDICATED ON THE PLANS. REFER

TO SECTION 27 10 00 STRUCTURED CABLING AND SECTION 27

05 33 CONDUITS AND BOXES FOR COMMUNICATIONS

SYSTEMS.

3. CONTRACTOR SHALL X-RAY CONCRETE FLOOR BEFORE CORE

DRILLING. CONTRACTOR SHALL COORDINATE WITH THE COR

BEFORE BEGINNING DRILLING.

4. CONTRACTOR SHALL FIRESTOP RISER SLEEVES AND EMPTY

SPARE RISER SLEEVES. REFER TO SECTION 07 84 00

FIRESTOPPING.

5. CONTRACTOR SHALL INSTALL AN VERTICAL LADDER TYPE

CABLE TRAY ON THE WALL ABOVE THE VERTICAL RISER

SLEEVES FOR BACKBONE CABLE SUPPORT AS INDICATED ON

THE PLANS. THE CABLE TRAY SHALL BE SECURELY

ANCHORED TO THE WALL SUFFICIENT TO SUPPORT THE

TOTAL WEIGHT OF CABLES AND CABLE TRAY PLUS 50%.

6. CONTRACTOR SHALL INSTALL CABLE SUPPORTS SUFFICIENT

TO SUPPORT COMMUNICATIONS CABLES ON THE VERTICAL

CABLE TRAY WITHOUT DAMAGING OR DEFORMING THE CABLE.

7. CONTRACTOR SHALL INSTALL NEW J-HOOKS WHERE THERE IS

NO CABLE TRAY OR COMMUNICATIONS CONDUIT UNLESS

OTHERWISE NOTED.

8. CONTRACTOR SHALL INSTALL NEW CATEGORY 6A PATCH

PANELS IN THE TELECOMMUNICATION ROOM AS INDICATED ON

RACK ELEVATIONS.

9. CONTRACTOR SHALL RE-TERMINATE AND TEST CABLING

REMOVED FROM ANY WALL MOUNT EQUIPMENT UNLESS

OTHERWISE NOTED. TESTING SHALL BE PERFORMED BY THE

CONTRACTOR DURING COMMISSIONING.

10. CONTRACTOR SHALL INSTALL NEW CATEGORY 6A

TELECOMMUNICATIONS/DATA OUTLET AS INDICATED.

EXISTING COMMUNICATION OUTLET BOXES AND CONDUITS TO

BE REUSED.

11. CONTRACTOR SHALL REPLACE ALL DATA CABLE WITH NEW

CATEGORY 6A CABLE UNLESS OTHERWISE NOTED.

12. CONTRACTOR SHALL TERMINATE COMMUNICATIONS CABLES

WITH NEW CATEGORY MODULAR JACKS TO MATCH THE

COMMUNICATION CABLE PERFORMANCE SPECIFICATIONS.

NEW MODULAR JACKS SHALL BE OF THE SAME

MANUFACTURER AS THE FACE PLATES, PATCH PANELS, AND

PATCH CABLES.

13. CONTRACTOR SHALL INSTALL NEW CATEGORY 6A CABLES

AND CONNECTIVITY COMPONENTS THAT ARE OF THE SAME

MANUFACTURER, INCLUDING CABLE, MODULAR JACKS, PATCH

PANELS, FACEPLATES, AND PATCH CABLES.

14. CONTRACTOR SHALL TEST ALL NEW AND EXISTING RE-

TERMINATED CABLES IN ACCORDANCE WITH THE

SPECIFICATION 27 05 11.

GENERAL NOTES:

5 5 10 15 20

1/8" = 1'-0"

G8G8

GG

FF

EE

DD

C8C8

19.6

19.6

19.8

19.8

20.8

20.8 21.2

21.2 22

H4H4

GW

GW

GW GW GW

CAM

CAM

CAM

CAM CAM

CAM

GW

6 4

NURSE MANAGER

4B-366

OFFICE

4B-368

SOILED SERVICE LOBBY

4C-312

MECHANICAL

4C-314

SOILED LINEN CHUTE

4C-312A

STAIR #8

STAIR

CORR.

4C-C7

TEL.

4C-316

ELEC.

4C-326

LIFT FUTURE

ELEV.

S-6

ELEV.

S-7

ELEV.

S-8

CLEAN SERVICE LOBBY

4C-322

HAC

4C-332

OFFICE

4C-334

MEDICAL STAFF OFFICE

4C-335

OFFICE

4C-336

STAFF/TOILET

4C-336A

OFFICE

4C-337

OFFICE

4C-236

SUBSTANCE ABUSE COORD.

4C-237

OFFICE

4C-238

ADDICTION PSYCHIATRIST

4C-239

TOILET

4C-237A

CORR.

4C-C2

INTERVIEW CONSULT

4C-200

ELEC.

4C-201

QUIET ROOM

4C-202

WORK ROOM

4C-203

GROUP THERAPY

4C-204

ANTE

4C-205

GROUP THERAPY

4C-206

ANTE

4C-207

INPATIENT/MHICM DR'S

4C-212

EXAM ROOM

4C-214

STAIR #9

STAIR

WC TOILET

4C-205B WC TOILET

4C-209A

WC TOILET

4C-213A

TOILET

4C-212A

TOILET

4C-208ATOILET

4C-204A

DAYROOM

4C-221

NURSE STATION WARD CLERK

4C-222

LEAD MSA/MHICM

4C-222A

EQUP. STORAGE

4C-222B

PSYCHIATRIST

4C-222C

NOUR.

4C-224

TELE SWITCH

4C-226

SOCIAL WORKER

4C-221A

TR

4C-234

PSYCHOLOGIST

4C-228

TOILET

4C-228A

SUBSTANCE ABUSE NURSE

4C-230 TOILET

4C-230A

GROUP THERAPY ROOM #3

4C-231

TOILET

4C-231A

ADDICT. THERAPIST

4C-232

WC TOILET

4C-232A

GROUP THERAPY ROOM #4

4C-233

ADDILT. THERAPIST

4C-235

TOILET

4C-233A

CLEAN LINEN

4C-240

UNISEX

4C-102

OFFICE

4C-103

UNISEX

4C-104

DINING SPACE

4B-292A

FEM. LOCKER LOUNGE

4B-293

FEM. TOIL.

4B-293A

LIFT

B01-TN317

KEY PLAN

AREA E

PLAN NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

6 South Old Orchard Ave, Saint Louis, MO 63119 T: 800.404.7677 www.introba.com

B

IM

/2

V

A W e s t P a lm

B e a c h

E H

R M

I n fr a s tr u c tu re U p g ra d e s D e s ig n /5

-7

.B

.T

R

.r v t

/2

/2

:1

:0

A

M

B01-TN140E

FOURTH LEVEL FLOOR PLAN -

AREA E - TELECOM

ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM)

INFRASTRUCTURE UPGRADES

WEST PALM BEACH, FL

548-22-700

03/31/23 PR TL

B01

1/8" = 1'-0"1

FOURTH LEVEL FLOOR PLAN - AREA E - TELECOM

1. EXISTING TELECOMMUNICATIONS ROOM.

2. EXISTING CONDITIONS WERE NOT OBSERVED ON SITE

VISITS, REFER TO AS BUILTS FOR DATA DEVICE LAYOUTS.

3. DATA OUTLET RELOCATED FROM DEMOLISHED WALL IN

NEW TR.

KEYED NOTES:#

1. REFER TO SHEET T-000 FOR GENERAL NOTES AND LEGENDS.

2. CONTRACTOR SHALL INSTALL BACKBONE RISER SLEEVES AND

CONDUITS OF THE SIZE AS INDICATED ON THE PLANS. REFER

TO SECTION 27 10 00 STRUCTURED CABLING AND SECTION 27

05 33 CONDUITS AND BOXES FOR COMMUNICATIONS

SYSTEMS.

3. CONTRACTOR SHALL X-RAY CONCRETE FLOOR BEFORE CORE

DRILLING. CONTRACTOR SHALL COORDINATE WITH THE COR

BEFORE BEGINNING DRILLING.

4. CONTRACTOR SHALL FIRESTOP RISER SLEEVES AND EMPTY

SPARE RISER SLEEVES. REFER TO SECTION 07 84 00

FIRESTOPPING.

5. CONTRACTOR SHALL INSTALL AN VERTICAL LADDER TYPE

CABLE TRAY ON THE WALL ABOVE THE VERTICAL RISER

SLEEVES FOR BACKBONE CABLE SUPPORT AS INDICATED ON

THE PLANS. THE CABLE TRAY SHALL BE SECURELY

ANCHORED TO THE WALL SUFFICIENT TO SUPPORT THE

TOTAL WEIGHT OF CABLES AND CABLE TRAY PLUS 50%.

6. CONTRACTOR SHALL INSTALL CABLE SUPPORTS SUFFICIENT

TO SUPPORT COMMUNICATIONS CABLES ON THE VERTICAL

CABLE TRAY WITHOUT DAMAGING OR DEFORMING THE CABLE.

7. CONTRACTOR SHALL INSTALL NEW J-HOOKS WHERE THERE IS

NO CABLE TRAY OR COMMUNICATIONS CONDUIT UNLESS

OTHERWISE NOTED.

8. CONTRACTOR SHALL INSTALL NEW CATEGORY 6A PATCH

PANELS IN THE TELECOMMUNICATION ROOM AS INDICATED ON

RACK ELEVATIONS.

9. CONTRACTOR SHALL RE-TERMINATE AND TEST CABLING

REMOVED FROM ANY WALL MOUNT EQUIPMENT UNLESS

OTHERWISE NOTED. TESTING SHALL BE PERFORMED BY THE

CONTRACTOR DURING COMMISSIONING.

10. CONTRACTOR SHALL INSTALL NEW CATEGORY 6A

TELECOMMUNICATIONS/DATA OUTLET AS INDICATED.

EXISTING COMMUNICATION OUTLET BOXES AND CONDUITS TO

BE REUSED.

11. CONTRACTOR SHALL REPLACE ALL DATA CABLE WITH NEW

CATEGORY 6A CABLE UNLESS OTHERWISE NOTED.

12. CONTRACTOR SHALL TERMINATE COMMUNICATIONS CABLES

WITH NEW CATEGORY MODULAR JACKS TO MATCH THE

COMMUNICATION CABLE PERFORMANCE SPECIFICATIONS.

NEW MODULAR JACKS SHALL BE OF THE SAME

MANUFACTURER AS THE FACE PLATES, PATCH PANELS, AND

PATCH CABLES.

13. CONTRACTOR SHALL INSTALL NEW CATEGORY 6A CABLES

AND CONNECTIVITY COMPONENTS THAT ARE OF THE SAME

MANUFACTURER, INCLUDING CABLE, MODULAR JACKS, PATCH

PANELS, FACEPLATES, AND PATCH CABLES.

14. CONTRACTOR SHALL TEST ALL NEW AND EXISTING RE-

TERMINATED CABLES IN ACCORDANCE WITH THE

SPECIFICATION 27 05 11.

GENERAL NOTES:

5 5 10 15 20

1/8" = 1'-0"

BB

A8A8

19.6

19.6

19.8

19.8

20.8

20.8 21.2

21.2 22

A6A6

AA

1 1 1 1

GW

GW

GW

GW

CAM

CAM

CAM

INTERVIEW CONSULT

4C-200

ELEC.

4C-201

WORK ROOM

4C-203

ANTE

4C-205

ANTE

4C-207

PSYCHIATRIST

4C-209

PSYCHIATRIST

4C-211

PSYCHOLOGIST

4C-213

STAIR #9

STAIR

NEUROPSYCHIATRIST

4C-216

SOCIAL WORKER

4C-205A

WC TOILET

4C-205B WC TOILET

4C-209A

WC TOILET

4C-213A

LEAD MSA/MHICM

4C-222A

CORR.

4C-C3

DIETICIAN

4C-111

OFFICE

4C-113

CHIEF OF MH & BS

4C-115

CHIEF OF PSYCHIATRY

4C-117

MULTI-PURPOSE

4C-119

HSS MH & BS SERVICE

4C-120

CHIEF PSYCH. OFFICE

4C-121

HSS MH &BS SERVICE

4C-122

STAFF TOILET

4C-123

UNISEX

4C-102

OFFICE

4C-103

UNISEX

4C-104

ELEV.

P-7

ELEV.

P-8

ELEV.

P-10

ELEV.

P-9

STAIR #7

STAIR

EDUCATION & DISCHARGE

4B-123

LMS COORD.

4B-125

CHIEF EES

4B-127

KEY PLAN

AREA F

PLAN NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

6 South Old Orchard Ave, Saint Louis, MO 63119 T: 800.404.7677 www.introba.com

B

IM

/2

V

A W e s t P a lm

B e a c h

E H

R M

I n fr a s tr u c tu re U p g ra d e s D e s ig n /5

-7

.B

.T

R

.r v t

/2

/2

:1

:1

A

M

B01-TN140F

FOURTH LEVEL FLOOR PLAN -

AREA F - TELECOM

ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM)

INFRASTRUCTURE UPGRADES

WEST PALM BEACH, FL

548-22-700

03/31/23 PR TL

B01

1/8" = 1'-0"1

FOURTH LEVEL FLOOR PLAN - AREA F - TELECOM

1. EXISTING TELECOMMUNICATIONS ROOM.

2. EXISTING CONDITIONS WERE NOT OBSERVED ON SITE

VISITS, REFER TO AS BUILTS FOR DATA DEVICE LAYOUTS.

3. DATA OUTLET RELOCATED FROM DEMOLISHED WALL IN

NEW TR.

KEYED NOTES:#

1. REFER TO SHEET T-000 FOR GENERAL NOTES AND LEGENDS.

2. CONTRACTOR SHALL INSTALL BACKBONE RISER SLEEVES AND

CONDUITS OF THE SIZE AS INDICATED ON THE PLANS. REFER

TO SECTION 27 10 00 STRUCTURED CABLING AND SECTION 27

05 33 CONDUITS AND BOXES FOR COMMUNICATIONS

SYSTEMS.

3. CONTRACTOR SHALL X-RAY CONCRETE FLOOR BEFORE CORE

DRILLING. CONTRACTOR SHALL COORDINATE WITH THE COR

BEFORE BEGINNING DRILLING.

4. CONTRACTOR SHALL FIRESTOP RISER SLEEVES AND EMPTY

SPARE RISER SLEEVES. REFER TO SECTION 07 84 00

FIRESTOPPING.

5. CONTRACTOR SHALL INSTALL AN VERTICAL LADDER TYPE

CABLE TRAY ON THE WALL ABOVE THE VERTICAL RISER

SLEEVES FOR BACKBONE CABLE SUPPORT AS INDICATED ON

THE PLANS. THE CABLE TRAY SHALL BE SECURELY

ANCHORED TO THE WALL SUFFICIENT TO SUPPORT THE

TOTAL WEIGHT OF CABLES AND CABLE TRAY PLUS 50%.

6. CONTRACTOR SHALL INSTALL CABLE SUPPORTS SUFFICIENT

TO SUPPORT COMMUNICATIONS CABLES ON THE VERTICAL

CABLE TRAY WITHOUT DAMAGING OR DEFORMING THE CABLE.

7. CONTRACTOR SHALL INSTALL NEW J-HOOKS WHERE THERE IS

NO CABLE TRAY OR COMMUNICATIONS CONDUIT UNLESS

OTHERWISE NOTED.

8. CONTRACTOR SHALL INSTALL NEW CATEGORY 6A PATCH

PANELS IN THE TELECOMMUNICATION ROOM AS INDICATED ON

RACK ELEVATIONS.

9. CONTRACTOR SHALL RE-TERMINATE AND TEST CABLING

REMOVED FROM ANY WALL MOUNT EQUIPMENT UNLESS

OTHERWISE NOTED. TESTING SHALL BE PERFORMED BY THE

CONTRACTOR DURING COMMISSIONING.

10. CONTRACTOR SHALL INSTALL NEW CATEGORY 6A

TELECOMMUNICATIONS/DATA OUTLET AS INDICATED.

EXISTING COMMUNICATION OUTLET BOXES AND CONDUITS TO

BE REUSED.

11. CONTRACTOR SHALL REPLACE ALL DATA CABLE WITH NEW

CATEGORY 6A CABLE UNLESS OTHERWISE NOTED.

12. CONTRACTOR SHALL TERMINATE COMMUNICATIONS CABLES

WITH NEW CATEGORY MODULAR JACKS TO MATCH THE

COMMUNICATION CABLE PERFORMANCE SPECIFICATIONS.

NEW MODULAR JACKS SHALL BE OF THE SAME

MANUFACTURER AS THE FACE PLATES, PATCH PANELS, AND

PATCH CABLES.

13. CONTRACTOR SHALL INSTALL NEW CATEGORY 6A CABLES

AND CONNECTIVITY COMPONENTS THAT ARE OF THE SAME

MANUFACTURER, INCLUDING CABLE, MODULAR JACKS, PATCH

PANELS, FACEPLATES, AND PATCH CABLES.

14. CONTRACTOR SHALL TEST ALL NEW AND EXISTING RE-

TERMINATED CABLES IN ACCORDANCE WITH THE

SPECIFICATION 27 05 11.

GENERAL NOTES:

5 5 10 15 20

1/8" = 1'-0"

G8G8

GG

FF

EE

DD

C8C8

CC

BB

A8A8

8 9

9 9.2

9.2 9.8

9.8 10.4

10.4

11.2

11.2 11.8

11.8

12.2

12.2

1818.2

18.2

19.6

19.6

19.8

19.8

20.8

20.821.2

21.2 22

A6A6

AA

H4H4

TR 1-4A-324

TR 1-4B-252

TR

1-4C-234

6 7

"x

"x

"x

"x

4"x4"

4"x4"

4"x4"

4"x4"

4"x4"

4"x4"

4"x4"

4"x4"

"x

"x

4"x4"

4"x4"

"x

"x

4"x4"

4"x4"

"x

"x

4"x4"

4"x4"

4"x4"

4"x4"

"x

"x

"x

"x

4"x4"

4"x4"

4"x4"

4"x4"

"x

"x

4"x4"

4"x4"

4"x4"

4"x4"

4"x4"

4"x4"

4"x4"

4"x4"

"x

"x

4"x4"

4"x4"

4"x4"

4"x4"

"x

"x

"x

"x

4"x4"

4"x4"

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

6 South Old Orchard Ave, Saint Louis, MO 63119 T: 800.404.7677 www.introba.com

B

IM

/2

V

A W e s t P a lm

B e a c h

E H

R M

I n fr a s tr u c tu re U p g ra d e s D e s ig n /5

-7

.B

.T

R

.r v t

/2

/2

:2

:0

A

M

B01-TN145

FOURTH INT LEVEL OVERALL

PLAN - TELECOM

ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM)

INFRASTRUCTURE UPGRADES

WEST PALM BEACH, FL

548-22-700

03/31/23 PR TL

B01

1" = 20'-0"1

FOURTH INT LEVEL OVERALL PLAN - TELECOM

1. PROVIDE (2) 4" CONDUITS FROM FOURTH LEVEL

RISER ROOM TO TR 1-5A-235 ON LEVEL ABOVE FOR A-

SIDE VERTICAL BACKBONE CABLING.

2. PROVIDE (2) 4" CONDUITS FROM FOURTH LEVEL

RISER ROOM TO TR 1-5B-232 ON LEVEL ABOVE FOR A-

SIDE VERTICAL BACKBONE CABLING.

3. EXISTING INTERSTITIAL CABLE TRAY

4. PROVIDE (1) 2" CONDUIT FROM RISER ROOM TO

EXISTING INTERSTITIAL CABLE TRAY FOR A-SIDE

BACKBONE PATHWAY.

5. PROVIDE (1) 2" CONDUIT FROM RISER ROOM TO

EXISTING INTERSTITIAL CABLE TRAY FOR B-SIDE

BACKBONE PATHWAY.

6. PROVIDE (1) 2" CONDUIT FROM EXISTING INTERSTITIAL

CABLE TRAY TO TR ON LEVEL BELOW FOR A-SIDE

BACKBONE PATHWAY.

7. PROVIDE (1) 2" CONDUIT FROM EXISTING INTERSTITIAL

CABLE TRAY TO TR ON LEVEL BELOW FOR B-SIDE

BACKBONE PATHWAY.

KEYED NOTES:#

PLAN NORTH

20 20 40

1" = 20'-0"

FEETSCALE

GENERAL NOTES:

1. CONTRACTOR SHALL COORDINATE THE EQUIPMENT'S

INSTALLATION AND FINAL LOCATION WITH THE ELECTRICAL

AND MECHANICAL DIVISION. REFER TO ELECTRICAL,

MECHANICAL AND PLUMBING DRAWINGS.

2. CONTRACTOR SHALL INSTALL PATHWAY DIVIDERS, RADIUS

DROP, AND ANY OTHER FITTING FOR A PROPER CABLE

RUNWAY INSTALLATION.

3. CONTRACTOR SHALL COORDINATE THE HILTI SPEED

SLEEVE LOCATIONS WITH THE PATHWAY SYSTEM LAYOUT

OUTSIDE EACH TELECOM ROOM. REFER TO FLOOR PLAN

DRAWINGS.

4. CONTRACTOR SHALL INSTALL BACKBONE RISER SLEEVES

AND CONDUITS OF THE SIZE AS INDICATED ON THE PLANS.

REFER TO SECTION 27 10 00 STRUCTURED CABLING AND

SECTION 27 05 33 CONDUITS AND BOXES FOR

COMMUNICATIONS SYSTEMS.

5. CONTRACTOR SHALL X-RAY CONCRETE FLOOR BEFORE

CORE DRILLING. CONTRACTOR SHALL COORDINATE WITH

THE COR BEFORE BEGINNING DRILLING.

6. CONTRACTOR SHALL FIRESTOP RISER SLEEVES AND EMPTY

SPARE RISER SLEEVES. REFER TO SECTION 07 84 00

FIRESTOPPING.

7. GOVERNMENT EQUIPMENT WILL BE RELOCATED BY

GOVERNMENT IT PERSONNEL. CONTRACTOR WILL HAVE

TECHNICIANS AVAILABLE TO PROVIDE SUPPORT DURING

OUTAGES AND CUT-OVERS. COORDINATE WORK WITH

THE COR.

8. CONTRACTOR SHALL PROVIDE MTP, FIBER OPTIC TRUNK

CABLES FOR SIDE A AND SIDE B BACKBONE FROM THE

DATA CENTER TO EACH TELECOMMUNICATIONS ROOM.

COORDINATE WITH COR.

9. CONTRACTOR SHALL PROVIDE FIBER OPTIC PATCH

CABLES FOR SIDE A AND SIDE B FROM THE FIBER OPTIC

DISTRIBUTOR TO EQUIPMENT CABINETS. COORDINATE

WITH COR.

10. CONTRACTOR SHALL VERIFY FIBER OPTIC CABLES

MEASUREMENTS PRIOR TO ORDERING. COORDINATE WITH

COR.

11. PATHWAY SHOWN IN HALFTONE IS EXISTING AND SHALL

REMAIN IN PLACE. ROUTE NEW FIBER OPTIC BACKBONE

CABLING THROUGH EXISTING INFRASTRUCTURE AS

G8G8

GG

FF

EE

DD

C8C8

CC

BB

A8A8

8 9

9 9.2

9.2 9.8

9.8 10.4

10.4

11.2

11.2 11.8

11.8

12.2

12.2

1818.2

18.2

19.6

19.6

19.8

19.8

20.8

20.821.2

21.2 22

A6A6

AA

H4H4

B01-TN318

B01-TN319

TR 1-5A-235

TR 1-5B-234

AREA A

AREA B

AREA C

AREA D

AREA E

AREA F

ROUTE CABLING TO

TELECOM ROOM

TR 1-5A-235

ROUTE CABLING TO

TELECOM ROOM

TR 1-5B-234

31 42

18"x4"

"x

18"x4" 18"x4" 18"x4"

"x

4"

"x

"x

"x

"x

4"

"x

4"

18"x4"

18"x4"

18"x4"

"x

18"x4"18"x4"

18"x4"

"x

"x

(4) SS44

(4) SS44

(4) SS44

(4) SS44

18"x4"

18"x4"

18"x4"

(4) SS44

(4) SS44

LEGEND

DELINIATATION LINE BETWEEN

TELECOM ROOMS. ROUTE THE CABLING

FOR ALL SYSTEMS TO THE TELECOM

ROOMS SHOWN ON THE DRAWINGS

BASED ON THIS SEPARATION LINE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

6 South Old Orchard Ave, Saint Louis, MO 63119 T: 800.404.7677 www.introba.com

B

IM

/2

V

A W e s t P a lm

B e a c h

E H

R M

I n fr a s tr u c tu re U p g ra d e s D e s ig n /5

-7

.B

.T

R

.r v t

/2

/2

:1

:1

A

M

B01-TN150

FIFTH LEVEL OVERALL PLAN -

TELECOM

ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM)

INFRASTRUCTURE UPGRADES

WEST PALM BEACH, FL

548-22-700

03/31/23 PR TL

B01

1" = 20'-0"1

FIFTH LEVEL OVERALL PLAN - TELECOM

PLAN NORTH

20 20 40

1" = 20'-0"

FEETSCALE

1. PROVIDE (2) 4" CONDUITS FROM FOURTH LEVEL

RISER ROOM TO TR 1-5A-235 ON LEVEL ABOVE FOR B-

SIDE VERTICAL BACKBONE CABLING.

2. PROVIDE (2) 4" CONDUITS FROM FOURTH LEVEL

RISER ROOM TO TR 1-5B-234 ON LEVEL ABOVE FOR A-

SIDE VERTICAL BACKBONE CABLING.

3. PROVIDE (2) 4" CONDUITS FROM TR 1-5A-235 TO TR

1-6A-235 ON LEVEL ABOVE FOR B-SIDE VERTICAL

BACKBONE CABLING.

4. PROVIDE (2) 4" CONDUITS FROM TR 1-5B-234 TO TR

1-6B-234 ON LEVEL ABOVE FOR A-SIDE VERTICAL

BACKBONE CABLING.

KEYED NOTES:#

GENERAL NOTES:

1. CONTRACTOR SHALL COORDINATE THE EQUIPMENT'S

INSTALLATION AND FINAL LOCATION WITH THE ELECTRICAL

AND MECHANICAL DIVISION. REFER TO ELECTRICAL,

MECHANICAL AND PLUMBING DRAWINGS.

2. CONTRACTOR SHALL INSTALL PATHWAY DIVIDERS, RADIUS

DROP, AND ANY OTHER FITTING FOR A PROPER CABLE

RUNWAY INSTALLATION.

3. CONTRACTOR SHALL COORDINATE THE HILTI SPEED

SLEEVE LOCATIONS WITH THE PATHWAY SYSTEM LAYOUT

OUTSIDE EACH TELECOM ROOM. REFER TO FLOOR PLAN

DRAWINGS.

4. CONTRACTOR SHALL INSTALL BACKBONE RISER SLEEVES

AND CONDUITS OF THE SIZE AS INDICATED ON THE PLANS.

REFER TO SECTION 27 10 00 STRUCTURED CABLING AND

SECTION 27 05 33 CONDUITS AND BOXES FOR

COMMUNICATIONS SYSTEMS.

5. CONTRACTOR SHALL X-RAY CONCRETE FLOOR BEFORE

CORE DRILLING. CONTRACTOR SHALL COORDINATE WITH

THE COR BEFORE BEGINNING DRILLING.

6. CONTRACTOR SHALL FIRESTOP RISER SLEEVES AND EMPTY

SPARE RISER SLEEVES. REFER TO SECTION 07 84 00

FIRESTOPPING.

7. GOVERNMENT EQUIPMENT WILL BE RELOCATED BY

GOVERNMENT IT PERSONNEL. CONTRACTOR WILL HAVE

TECHNICIANS AVAILABLE TO PROVIDE SUPPORT DURING

OUTAGES AND CUT-OVERS. COORDINATE WORK WITH

THE COR.

8. CONTRACTOR SHALL PROVIDE MTP, FIBER OPTIC TRUNK

CABLES FOR SIDE A AND SIDE B BACKBONE FROM THE

DATA CENTER TO EACH TELECOMMUNICATIONS ROOM.

COORDINATE WITH COR.

9. CONTRACTOR SHALL PROVIDE FIBER OPTIC PATCH

CABLES FOR SIDE A AND SIDE B FROM THE FIBER OPTIC

DISTRIBUTOR TO EQUIPMENT CABINETS. COORDINATE

WITH COR.

10. CONTRACTOR SHALL VERIFY FIBER OPTIC CABLES

MEASUREMENTS PRIOR TO ORDERING. COORDINATE WITH

COR.

11. PATHWAY SHOWN IN HALFTONE IS EXISTING AND SHALL

REMAIN IN PLACE. ROUTE NEW FIBER OPTIC BACKBONE

CABLING THROUGH EXISTING INFRASTRUCTURE AS

G8G8

GG

FF

EE

DD

C8C8

8 9

9 9.2

9.2 9.8

9.82

H4H4

STAIR #4

STAIR

SEMI-PRIVATE

5A-332

SEMI-PRIVATE

5A-330

SEMI-PRIVATE

5A-328

SEMI-PRIVATE

5A-326

SEMI-PRIVATE

5A-324

SEMI-PRIVATE

5A-322

PAIN PROCEDURE

5A-320

W/C BATH

5A-320A

W/C BATH

5A-324A

W/C BATH

5A-328A

W/C BATH

5A-332A

PRIVATE

5A-125

ORTHOPEDICS

5A-123

ORTHOPEDICS

5A-121

PRIVATE

5A-119A

ORTHOPEDICS

5A-117A

DOCTOR'S OFFICE

5A-115A

ORTHOPEDIC SURGERY

5A-113

DOCTOR'S OFFICE

5A-111

LPN

5A-105B

STAFF OFFICES

5A-105

ANTE

5A-115

SPINE SURGERY

5A-117

W/C BATH

5A-27A

W/C BATH

5A-121A

W/C BATH

5A-117A

W/C BATH

5A-115B

W/C BATH

5A-111A

CLEAN LINEN

5A-255

CASTING RM.

5A-253

NURSING EXAM.

5A-251

ORTHOPEDICS

5A-234

EQUIP. STOR.

5A-256

PHYS. ASSIST. NURSE CLINICIAN

5A-232

STAFF TLT

5A-239

CLEAN UTILITY

5A-243

SOIL UTILITY

5A-241

ELEC.

5A-237

TR

5A-235

PREP. OP CLINIC

5A-214

ORTHOPEDICS

5A-231

DOC. CHART DICT.

5A-210A

NURSES STATION / WARD CLERK

5A-210

PYXIS ROOM

5A-210B

COPIER RM.

5A-210C

NOURISH

5A-212

STOR.

5A-214A

ROOM

5A-202

WOUND CARE

5A-204

SEMI-PRIVATE

5A-211

SEMI-PRIVATE

5A-213

SEMI-PRIVATE

5A-215

SEMI-PRIVATE

5A-217

STAFF LOUNGE / LOCKERS

5A-221

W/C TLT.

5A-221A

FEMALE TLT. / SHOWERS

5A-219A

STRETCHER / W/C

5A-221

W/C BATH

5A-215A

W/C BATH

5A-211A

CORRIDOR

5A-C7

CORR.

5A-C2

CORR.

5A-C4

CORR.

5A-C1

HAC

5A-312

STOR.

5A-314

STORAGE UTIL.

5A-316DISPOSAL CHUTE VEST

5A-318

MECHANICAL

5A-304A

MALE TOILET

5B-200

CORRIDOR

5B-C7

SOILED SERVICE LOBBY

5B-302

SOILED LINEN CHUTE

5B-302A

ELECT.

5B-302B

TEL.

5B-302C

STAIR #5

STAIR

ELEV.

S-5

ELEV.

S-4

STORAGE

5B-304B

3 3

2 2

5 5

33 3 3 4

1 1

EX

GW

GW

GW

GW

GW

CAM

CAM

CAM

CAM

B01-TN318

MECH.

5B-304C

KEY PLAN

AREA A

PLAN NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

6 South Old Orchard Ave, Saint Louis, MO 63119 T: 800.404.7677 www.introba.com

B

IM

/2

V

A W e s t P a lm

B e a c h

E H

R M

I n fr a s tr u c tu re U p g ra d e s D e s ig n /5

-7

.B

.T

R

.r v t

/2

/2

:1

:2

A

M

B01-TN150A

FIFTH LEVEL FLOOR PLAN - AREA

A - TELECOM

ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM)

INFRASTRUCTURE UPGRADES

WEST PALM BEACH, FL

548-22-700

03/31/23 PR TL

B01

1/8" = 1'-0"1

FIFTH LEVEL FLOOR PLAN - AREA A - TELECOM

1. EXISTING TELECOMMUNICATIONS ROOM.

2. EXISTING CONDITIONS WERE NOT OBSERVED ON SITE

VISITS, REFER TO AS BUILTS FOR DATA DEVICE LAYOUTS.

3. DATA OUTLET RELOCATED FROM DEMOLISHED WALL IN

NEW TR.

KEYED NOTES:#

1. REFER TO SHEET T-000 FOR GENERAL NOTES AND LEGENDS.

2. CONTRACTOR SHALL INSTALL BACKBONE RISER SLEEVES AND

CONDUITS OF THE SIZE AS INDICATED ON THE PLANS. REFER

TO SECTION 27 10 00 STRUCTURED CABLING AND SECTION 27

05 33 CONDUITS AND BOXES FOR COMMUNICATIONS

SYSTEMS.

3. CONTRACTOR SHALL X-RAY CONCRETE FLOOR BEFORE CORE

DRILLING. CONTRACTOR SHALL COORDINATE WITH THE COR

BEFORE BEGINNING DRILLING.

4. CONTRACTOR SHALL FIRESTOP RISER SLEEVES AND EMPTY

SPARE RISER SLEEVES. REFER TO SECTION 07 84 00

FIRESTOPPING.

5. CONTRACTOR SHALL INSTALL AN VERTICAL LADDER TYPE

CABLE TRAY ON THE WALL ABOVE THE VERTICAL RISER

SLEEVES FOR BACKBONE CABLE SUPPORT AS INDICATED ON

THE PLANS. THE CABLE TRAY SHALL BE SECURELY

ANCHORED TO THE WALL SUFFICIENT TO SUPPORT THE

TOTAL WEIGHT OF CABLES AND CABLE TRAY PLUS 50%.

6. CONTRACTOR SHALL INSTALL CABLE SUPPORTS SUFFICIENT

TO SUPPORT COMMUNICATIONS CABLES ON THE VERTICAL

CABLE TRAY WITHOUT DAMAGING OR DEFORMING THE CABLE.

7. CONTRACTOR SHALL INSTALL NEW J-HOOKS WHERE THERE IS

NO CABLE TRAY OR COMMUNICATIONS CONDUIT UNLESS

OTHERWISE NOTED.

8. CONTRACTOR SHALL INSTALL NEW CATEGORY 6A PATCH

PANELS IN THE TELECOMMUNICATION ROOM AS INDICATED ON

RACK ELEVATIONS.

9. CONTRACTOR SHALL RE-TERMINATE AND TEST CABLING

REMOVED FROM ANY WALL MOUNT EQUIPMENT UNLESS

OTHERWISE NOTED. TESTING SHALL BE PERFORMED BY THE

CONTRACTOR DURING COMMISSIONING.

10. CONTRACTOR SHALL INSTALL NEW CATEGORY 6A

TELECOMMUNICATIONS/DATA OUTLET AS INDICATED.

EXISTING COMMUNICATION OUTLET BOXES AND CONDUITS TO

BE REUSED.

11. CONTRACTOR SHALL REPLACE ALL DATA CABLE WITH NEW

CATEGORY 6A CABLE UNLESS OTHERWISE NOTED.

12. CONTRACTOR SHALL TERMINATE COMMUNICATIONS CABLES

WITH NEW CATEGORY MODULAR JACKS TO MATCH THE

COMMUNICATION CABLE PERFORMANCE SPECIFICATIONS.

NEW MODULAR JACKS SHALL BE OF THE SAME

MANUFACTURER AS THE FACE PLATES, PATCH PANELS, AND

PATCH CABLES.

13. CONTRACTOR SHALL INSTALL NEW CATEGORY 6A CABLES

AND CONNECTIVITY COMPONENTS THAT ARE OF THE SAME

MANUFACTURER, INCLUDING CABLE, MODULAR JACKS, PATCH

PANELS, FACEPLATES, AND PATCH CABLES.

14. CONTRACTOR SHALL TEST ALL NEW AND EXISTING RE-

TERMINATED CABLES IN ACCORDANCE WITH THE

SPECIFICATION 27 05 11.

GENERAL NOTES:

5 5 10 15 20

1/8" = 1'-0"

BB

A8A8

8 9

9 9.2

9.2 9.8

9.82

A6A6

AA

ORTHOPEDIC SURGERY

5A-113

DOCTOR'S OFFICE

5A-111

CHIEF PODIATRY

5A-105A

LPN

5A-105B

STAFF OFFICES

5A-105

CONFERENCE ROOM

5A-103

WAITING ROOM

5A-101

STAIR #2

STAIR

ROOM

5A-202

WOUND CARE

5A-204

MALE TOILET

5B-200

ELEV.

P-1

ELEV.

P-2

ELEV.

P-3

EX

GW

CAM

CAM

KEY PLAN

AREA B

PLAN NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

6 South Old Orchard Ave, Saint Louis, MO 63119 T: 800.404.7677 www.introba.com

B

IM

/2

V

A W e s t P a lm

B e a c h

E H

R M

I n fr a s tr u c tu re U p g ra d e s D e s ig n /5

-7

.B

.T

R

.r v t

/2

/2

:1

:3

A

M

B01-TN150B

FIFTH LEVEL FLOOR PLAN - AREA

B - TELECOM

ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM)

INFRASTRUCTURE UPGRADES

WEST PALM BEACH, FL

548-22-700

03/31/23 PR TL

B01

1/8" = 1'-0"1

FIFTH LEVEL FLOOR PLAN - AREA B - TELECOM

1. EXISTING TELECOMMUNICATIONS ROOM.

2. EXISTING CONDITIONS WERE NOT OBSERVED ON SITE

VISITS, REFER TO AS BUILTS FOR DATA DEVICE LAYOUTS.

3. DATA OUTLET RELOCATED FROM DEMOLISHED WALL IN

NEW TR.

KEYED NOTES:#

1. REFER TO SHEET T-000 FOR GENERAL NOTES AND LEGENDS.

2. CONTRACTOR SHALL INSTALL BACKBONE RISER SLEEVES AND

CONDUITS OF THE SIZE AS INDICATED ON THE PLANS. REFER

TO SECTION 27 10 00 STRUCTURED CABLING AND SECTION 27

05 33 CONDUITS AND BOXES FOR COMMUNICATIONS

SYSTEMS.

3. CONTRACTOR SHALL X-RAY CONCRETE FLOOR BEFORE CORE

DRILLING. CONTRACTOR SHALL COORDINATE WITH THE COR

BEFORE BEGINNING DRILLING.

4. CONTRACTOR SHALL FIRESTOP RISER SLEEVES AND EMPTY

SPARE RISER SLEEVES. REFER TO SECTION 07 84 00

FIRESTOPPING.

5. CONTRACTOR SHALL INSTALL AN VERTICAL LADDER TYPE

CABLE TRAY ON THE WALL ABOVE THE VERTICAL RISER

SLEEVES FOR BACKBONE CABLE SUPPORT AS INDICATED ON

THE PLANS. THE CABLE TRAY SHALL BE SECURELY

ANCHORED TO THE WALL SUFFICIENT TO SUPPORT THE

TOTAL WEIGHT OF CABLES AND CABLE TRAY PLUS 50%.

6. CONTRACTOR SHALL INSTALL CABLE SUPPORTS SUFFICIENT

TO SUPPORT COMMUNICATIONS CABLES ON THE VERTICAL

CABLE TRAY WITHOUT DAMAGING OR DEFORMING THE CABLE.

7. CONTRACTOR SHALL INSTALL NEW J-HOOKS WHERE THERE IS

NO CABLE TRAY OR COMMUNICATIONS CONDUIT UNLESS

OTHERWISE NOTED.

8. CONTRACTOR SHALL INSTALL NEW CATEGORY 6A PATCH

PANELS IN THE TELECOMMUNICATION ROOM AS INDICATED ON

RACK ELEVATIONS.

9. CONTRACTOR SHALL RE-TERMINATE AND TEST CABLING

REMOVED FROM ANY WALL MOUNT EQUIPMENT UNLESS

OTHERWISE NOTED. TESTING SHALL BE PERFORMED BY THE

CONTRACTOR DURING COMMISSIONING.

10. CONTRACTOR SHALL INSTALL NEW CATEGORY 6A

TELECOMMUNICATIONS/DATA OUTLET AS INDICATED.

EXISTING COMMUNICATION OUTLET BOXES AND CONDUITS TO

BE REUSED.

11. CONTRACTOR SHALL REPLACE ALL DATA CABLE WITH NEW

CATEGORY 6A CABLE UNLESS OTHERWISE NOTED.

12. CONTRACTOR SHALL TERMINATE COMMUNICATIONS CABLES

WITH NEW CATEGORY MODULAR JACKS TO MATCH THE

COMMUNICATION CABLE PERFORMANCE SPECIFICATIONS.

NEW MODULAR JACKS SHALL BE OF THE SAME

MANUFACTURER AS THE FACE PLATES, PATCH PANELS, AND

PATCH CABLES.

13. CONTRACTOR SHALL INSTALL NEW CATEGORY 6A CABLES

AND CONNECTIVITY COMPONENTS THAT ARE OF THE SAME

MANUFACTURER, INCLUDING CABLE, MODULAR JACKS, PATCH

PANELS, FACEPLATES, AND PATCH CABLES.

14. CONTRACTOR SHALL TEST ALL NEW AND EXISTING RE-

TERMINATED CABLES IN ACCORDANCE WITH THE

SPECIFICATION 27 05 11.

GENERAL NOTES:

5 5 10 15 20

1/8" = 1'-0"

G8G8

GG

FF

EE

DD

C8C8

9.8

9.8 10.4

10.4

11.2

11.2 11.8

11.8

12.2

12.2

18 18.2

18.2

H4H4

MALE TOILET

5B-200

SURGICAL NURSES

5B-201

FEMALE TLT.

5B-202

CORRIDOR

5B-C7

SOILED SERVICE LOBBY

5B-302

ELECT.

5B-302B

TEL.

5B-302C

ELEV.

S-5

ELEV.

S-4

STORAGE

5B-304B

ELEV.

S-1

ELEV.

S-2

ELEV.

S-3

PATIENT SERVICE LOBBY

5B-306

EQUIP. STORAGE

5B-304

MECHANICAL

5B-304A-S

OFFICE

5B-312

BATT. CHARGE

5B-314

HAC

5B-316

EYE CLINIC

5B-318

UROLOGY NURSES STATION / WARD

CLERK

5B-211

OFFICE

5B-213

GENERAL SURGERY

5B-214

STOR.

5B-215

OPHTHAMOLOGY

5B-216

VASCULAR GENERAL

5B-217

FACS

5B-218

M. STAFF TLT.

5B-220

STAFF LOUNGE / LOCKERS

5B-221

F. TLT.

5B-223

CLEAN LINEN

5B-225

STAFF TLT.

5B-221A

MED PREP

5B-211A

OFFICE

5B-211B

DOC. CHART DICT.

5B-211C

EYE CLINIC WAITING RM

5B-241

W/C BATH

5B-216A

W/C BATH

5B-212A

CLINIC PRE-OP

5B-206

NURSING OFFICE

5B-208

ANISTHESIA

5B-204

SUPPLY CLOSET

5B-206A

ALCOVE

5B-C1

EXAM ROOM

5B-230

TR

5B-234

TELE.

5B-234

ELEC.

5B-236

SCREENING

5B-243

STAFF TLT.

5B-238

CORR.

5B-C2

CORR.

5B-C4

UROLOGY

5B-320

UROLOGY

5B-322

UROLOGY

5B-324

UROLOGY

5B-326

MINOR PROCEDURE

5B-328

UROLOGY

5B-330

PAIN CLINIC / MINOR PROCEDURE

5B-332

W/C BATH

5B-320A

W/C BATH

5B-324A

W/C BATH

5B-328A W/C BATH

5B-332A

STAIR #6

STAIR

OFFICE

5B-231

OFFICE

5B-233

EXAM.

5B-251

CLEAN SUPPLY RM.

5B-253

STAFF OMLY

5B-255

EQUIP. STOR.

5B-256

PLASTIC SURGERY

5B-111

UROLOGY

5B-113A

ANTE

5B-115

ANTE

5B-117

UROLOGY

5B-119

UROLOGY

5B-121

UROLOGY

5B-123

OFFICE

5B-125

W/C BATH

5B-123A

W/C BATH

5B-119A

W/C BATH

5B-117B

UROLOGY

5B-117AW/C BATH

5B-115B

UROLOGY

5B-115A

W/C BATH

5B-111A

4 3

3 2

4 4

1 1 3 3 3 3

4 4

GW

GW

GW

CAM

CAM

CAM

CAM

AREA UNDER CONSTRUCTION,

EXISTING CONDITIONS WERE NOT

OBSEREVED

GW

GW

GW

GW

B01-TN319

MECH.

5B-304C

KEY PLAN

AREA C

PLAN NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

6 South Old Orchard Ave, Saint Louis, MO 63119 T: 800.404.7677 www.introba.com

B

IM

/2

V

A W e s t P a lm

B e a c h

E H

R M

I n fr…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .