This file is an attachment to a solicitation for the Y1AZ--EHRM Infrastructure Upgrades Construction project at the West Palm Beach VA Medical Center. The Department of Veterans Affairs Technology Acquisition Center Austin is seeking construction services to upgrade infrastructure including structural work. Offerors must submit proposals by the date listed in the solicitation to be considered for award, which is expected in mid-2022. Small businesses, veteran-owned small businesses, service-disabled veteran-owned small businesses, and HUBZone small businesses will receive preference in accordance with federal regulations. The scope of work involves structural upgrades to ensure the electronic health records modernization initiative can be properly implemented at this facility.
View the file
Other files for this federal contract opportunity
Show all 37
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
W10X22 (6)
W10X22 (6)
W10X22 (6)
W10X22 (6)
C 8X
.7
C 8X
.7
C 8X
.7
C 8X
.7
C 8X
.7
C 8X
.7
W
X
(6
G.8
9.8
4"
E Q
E Q
E Q
B01-S100
B01-S100
NOTES:
1. FRAMING PLAN APPLICABLE FOR ALL LEVELS. COORDINATE WITH ARCHITECTURAL AND ELECTRICAL DRAWINGS AS REQUIRED
2. CONTRACTOR TO FIELD VERIFY ALL EXISTING DIMENSIONS
3. T/SLAB = EXISTING FINISH FLOOR ELEVATION. CONTRACTOR TO FIELD VERIFY
4. T/STEEL = 0'-5" BELOW EXISTING FINISH FLOOR ELEVATION
5. ALL SHEAR CONNECTIONS TO BE DESIGNED FOR A MINIMUM FACTORED LOAD OF 10 KIPS
6. SEE B23-S100 FOR STRUCTURAL GENERAL NOTES
7. REFER TO EXISTING BUILDING 1 DRAWINGS TITLED "NEW GENERAL MEDICAL, SURGICAL, INTERMEDIATE CARE, AND PSYCHIATRIC
HOSPITAL" FOR MORE INFORMATION ON EXISTING CONDITIONS
B01-S100
B01-S100
FRAMING BEAM ONLY REQUIRED ON
LEVELS WITH UPS EQUIPMENT.
COORDINATE WITH ARCHITECTURE
AND ELECTRICAL DRAWINGS
NEW INFILL FLOOR 3.5"
CONCRETE SLAB ON 1.5"
COMPOSITE METAL DECK.
PROVIDE WWF 6X6 W1.4/W1.4
MESH
11 67/128" 6' - 6" 4"
B01-S100
SIM
4"
5'
/2
5'
1/
6" 5'
3/
6"
1/
2"
EXISTING MASONRY INFILL
WALL. COORDINATE WITH
ARCHITECTURE DEMO
PLANS AS REQUIRED
EXISTING COLUMN
CLR
2' - 0"
C
LR
2'
C8X13.7 AT
BASEMENT LEVEL
ONLY FOR
ACCESS HATCH
TO SUMP PITS
BELOW
B01-S100
9.8
STEEL FRAMING PER PLAN
SLAB PER PLAN
EXISTING CONCRETE COLUMN
EXISTING SOFFIT BEAM
EXISTING SLAB. DEMO HAUNCH AS REQUIRED TO
INSTALL NEW STEEL SUPPORT
STANDRARD AISC SHEAR CONNECTION. CONTRACTOR
OPTION FOR SHEAR TAB OR ANGLE CONNECTION
EXISTING CONCRETE COLUMN
4"
12"X16"X1/2" PLATE W/ (8) 1/2 DIA HILIT KWIK BOLT EXPANSION
ANCHORS OR APPROVED EQUAL. MINIMUM EMBED 4"
4" 4"
4"
MIN
1' - 6"
#4 REBAR @ 18" OC. DRILL AND
EPOXY INTO EXISTING SLAB
T/SLAB
PER PLAN
T/STEEL
PER PLAN
BEAM LEGEND
W18X40 C=1"
CAMBERBEAM SIZE
20K20K
BEAM REACTION, TYP
(8) (8)(4)
QUANTITY OF SHEAR STUDS,
UNIFORMLY SPACED BETWEEN
ADJACENT FRAMING, TYP
(COMPOSITE CONSTRUCTION ONLY)
NOTES:
1) REACTION VALUE IS ASD (KIPS), UNO.
2) WHERE NO VALUE IS SHOWN, DESIGN CONNECTION FOR A MINIMUM REACTION OF 10 KIPS.
3) SPACE STUDS PER TYPICAL SHEAR STUD PLACEMENT DETAIL. MINIMUM NUMBER OF STUDS
PER GENERAL NOTES.
6) BEAMS ARE PRIMARY MEMBERS FOR FIREPROOFING UNLESS NOTED AS SECONDARY.
7) POSITIVE CAMBER UPWARDS, NEGATIVE CAMBER DOWNWARDS. CAMBER SHOWN
ON CANTILEVERS IS AT END OF CANTILEVER.
5/8" Ø PUDDLE WELD, TYP
3 - #10 TEX SIDELAP FASTENERS
EACH JOIST SPACE
36/4 WELD PATTERN AT ALL SUPPORTS
WELD REQUIRED AT ALL
SIDELAP SUPPORT POINTS
NOTE: WELD THROUGH MULTIPLE SHEETS AT ALL END AND SIDE
LAPS END LAPS SHALL OCCUR ONLY AT SUPPORT POINTS
1 1/2" WIDE RIB, 22 GAGE METAL ROOF
DECK - MINIMUM THREE SPAN CONDITION.
S E E P
LA
N
S E E P
LA
N
S E E P
LA
N
S H E E T W
ID
T
H#4 REBAR @ 18" OC. DRILL AND
EPOXY INTO EXISTING SLAB
MIN
6"
MIN
1' - 0"
STEEL SUPPORT PER PLAN
EXISTING CMU INFILL
EXISTING CMU INFILL
EXISTING
CONCRETE BEAM
EXISTING SLAB
T/SLAB
PER PLAN
T/STEEL
PER PLAN
4" 4"
4"
2 3/4" 3 1/2" 3 1/2"
3 1/2" 2 3/4"
1/2"X12"X16" PLATE W/ (8) 1/2 DIA HILIT KWIK BOLT EXPANSION
ANCHORS OR APPROVED EQUAL. MINIMUM EMBED 4"
EXISTING CONCRETE HAUNCH. DEMO AS REQUIRED
FOR CONNECTION AND SLAB INSTALATION
EXISTING CONCRETE SLAB
STEEL SUPPORT PER PLAN
EXISTING MASONRY INFILL
EXISTING CONCRETE COLUMN
EXISTING CONCRETE BEAM
NEW SLAB PER PLAN
NOTES:
1. ADDITIONAL STEEL SUPPORTS NOT SHOWN FOR CLARITY
T/SLAB
PER PLAN
T/STEEL
PER PLAN
BEAM PER PLAN
SLAB PER PLAN
STANDARD AISC SHEAR CONNECTION.
CONTRACTOR OPTION FOR SHEAR TAB
OR ANGLE CONNECTION
T/SLAB
PER PLAN
T/STEEL
PER PLAN
G.8
1/2"X12"X14" PLATE W/ (9) 1/2 DIA HILIT KWIK BOLT EXPANSION
ANCHORS OR APPROVED EQUAL. MINIMUM EMBED 4"
STEEL SUPPORT PER PLAN
EXISTING MASONRY INFILL
EXISTING CONCRETE BEAM
NEW SLAB PER PLAN
NOTES:
1. ADDITIONAL STEEL SUPPORTS NOT SHOWN FOR CLARITY
T/SLAB
PER PLAN
T/STEEL
PER PLAN
3" 3"
3" 3"
3" 3" 6" 2"
1' - 2" 1'
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
B
IM
/2
V
A W e s t P a lm
B e a c h
E H
R M
I n fr a s tr u c tu re U p g ra d e s D e s ig n /2
.1
B ld g v
.r v t
/2
/2
:4
:3
P
M
B01-S100
UPS/STORAGE ROOM FRAMING
PLANS AND DETAILS10360 ellison Circle
Omaha, NE 68134
402.991.5520 specializedeng.com
1221 N. Pennsylvania St.
Indianapolis, IN 46202
317.800.6388 guidondesign.com
ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM)
INFRASTRUCTURE UPGRADES
WEST PALM BEACH, FL
548-22-700
B01
03/31/2023 LKL ADK
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
SCALE: 1/2" = 1'-0"B01-S100
1 TYPICAL UPS/STORAGE ROOM INFILL FRAMING PLAN
SCALE: 3/4" = 1'-0"B01-S100
3 FRAMING SECTION
SCALE: 3/4" = 1'-0"B01-S100
2 TYPICAL ROOF DECK WELDING PATTERNS
SCALE: 3/4" = 1'-0"B01-S100
4 FRAMING SECTION
SCALE: 3/4" = 1'-0"B01-S100
5 FRAMING SECTION
SCALE: 3/4" = 1'-0"B01-S100
7 FRAMING SECTION
SCALE: 3/4" = 1'-0"B01-S100
6 FRAMING SECTION
Revisions: Date:
MISCELLANEOUS SYMBOLS
NORTH ARROW
GRIDLINES
EARTH
SECTION NUMBER
SHEET NUMBER
S101
S101
CALLOUT NUMBER
SHEET NUMBER
A
ELEVATION REFERENCE
LIMIT OF EXTENT
CONTINUOUS EXTENT
F ## COLUMN FOOTING NOTATION
GB ## GRADE BEAM NOTATION
P ## PIER NOTATION
B ## CONCRETE BEAM NOTATION
PC ## PILE CAP NOTATION
WF ## WALL FOOTING NOTATION
SHEAR WALL NOTATIONSW ##
BW ## BEARING WALL NOTATION
GRAVEL
Name
Elevation
TF ## TRENCH FOOTING NOTATION
FLOOR DRAIN
FD
N
4" NW CONCRETE SLAB W/
6X6-W2.1XW2.1 WWF ON 1 1/2"
20 GA. COMPOSITE DECK.
TOTAL THICKNESS = 5 1/2"
DIRECTION OF SPAN
CONCRETE WASH
CONCRETE SYMBOLS
REBAR
CHANGE OF SLAB
ELEVATION
SLOPING SLAB
CHANGE OF SLAB
THICKNESS
MECHANICAL COUPLER
REBAR SPLICE
LIMIT OF MEMBER OR
SPAN MARK
DIRECTION OF SPAN
OPENING
SELF-EXPANDING
WATERSTOP
CONTROL JOINT LOCATION
IN CONCRETE WALLS
REBAR TERMINATOR
INTENTIONALLY
ROUGHENED
CONSTRUCTION JOINT
TO 1/4" AMPLITUDE
WELDED WIRE FABRIC
PVC WATERSTOP
COLUMN CONTINUES
COLUMN TERMINATED
FORM-SAVER
BAR SIZE VERTICAL BARS HORIZONTAL BARS
#3 1'-10" 2'-4" 1'-10"
#4 2'-5" 3'-1" 2'-5"
#5 3'-0" 3'-11" 3'-0"
#6 3'-7" 4'-8" 3'-7"
#7 5'-3" 6'-9" 5'-3"
#8 6'-0" 7'-9" 6'-0"
#9 6'-9" 8'-9" 6'-9"
NOTES:
1. HORIZONTAL "BOTTOM" BARS ARE BARS 12" OR LESS FROM THE BOTTOM OF A
FOOTING, SLAB, OR OTHER CONCRETE MEMBER
2. ALL REINFORCING BARS ARE TO BE SPLICED WITH A CLASS B LAP SPLICE, U.N.O.
HORIZONTAL BOTTOM BARS
CONCRETE CONSTRUCTION
CLASS B LAP SPLICE LENGTHS
BEAM LEGEND
W18X40 C=1"
CAMBERBEAM SIZE
(8) (8)(4)
QUANTITY OF SHEAR STUDS,
UNIFORMLY SPACED BETWEEN
ADJACENT FRAMING, TYP
(COMPOSITE CONSTRUCTION ONLY)
NOTES:
1) REACTION VALUE IS ASD (KIPS), UNO.
2) SPACE STUDS PER TYPICAL SHEAR STUD PLACEMENT DETAIL. MINIMUM NUMBER OF STUDS
PER GENERAL NOTES.
3) BEAMS ARE PRIMARY MEMBERS FOR FIREPROOFING UNLESS NOTED AS SECONDARY.
4) POSITIVE CAMBER UPWARDS, NEGATIVE CAMBER DOWNWARDS. CAMBER SHOWN
ON CANTILEVERS IS AT END OF CANTILEVER.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
B
IM
/2
V A
W e s t P a lm
B e a c h
E H
R M
I n fr a s tr u c tu re U p g ra d e s D e s ig n /2
.1
S v
.r v t
/2
/2
:4
:5
P
M
SI001
STRUCTURAL ABBREVIATIONS
10360 Ellison Circle
Omaha, NE 68134
402.991.5520 specializedeng.com
1221 N. Pennsylvania St.
Indianapolis, IN 46202
317.800.6388 guidondesign.com
ELETRONIC HEALTH RECORD
MODERNIZATION (EHRM)
INFRASTRUCTURE UPGRADES
WEST PALM BEACH, FL
548-22-700
03/31/2023 LKL ADK
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
STRUCTURAL ABBREVIATIONS
JST JOIST
JT JOINT
KB KNEE BRACE
KIP, K 1,000 POUNDS
KO KNOCK-OUT
KSI KIPS PER SQUARE INCH
L ANGLE OR LENGTH
LAB LABRATORY
LB POUND
LF LINEAL FOOT
LIN LINEAL, LINEAR
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LONGIT LONGITUDINAL
LP LOW POINT
LSLT LONG SLOTTED HOLE
LTWT LIGHT WEIGHT
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MB MACHINE BOLT
MC MISCELLANEOUS CHANNEL
MECH MECHANICAL
MEMB MEMBRANE
MEP MECHANICAL/ ELECTRICAL/ PLUMBING
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MULT MULTIPLE
N/A NOT APPLICABLE
NO NUMBER
NOM NOMINAL
NS NEAR SIDE
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OF OUTSIDE FACE
OFD OVERFLOW DRAIN
OH OVERHEAD
OPNG OPENING
OPP OPPOSITE
OPPHD OPPOSITE HAND
ORIG ORIGINAL
OVS OVERSIZED HOLE
P PIER
PC PIER CAP OR PRECAST
PERIM PERIMETER
PERM PERMANENT
PERP PERPENDICULAR
PJP PARTIAL JOINT PENETRATION
PL PLATE
PLF POUNDS PER LINEAL FOOT
PLYWD PLYWOOD
PREFAB PREFABRICATED
PREL PRELIMINARY
PREP PREPARATION, PREPARE
PROJ PROJECTION
PS PRESTRESSED
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PSL PARALLEL STRAND LUMBER
PT POST-TENSIONED
R RADIUS
RD ROOF DRAIN
REF REFERENCE
REINF REINFORCEMENT, REINFORCE
REQD REQUIRED
RO ROUGH OPENING
SCH SCHEDULE
SECT SECTION
SF SQUARE FEET
SHT SHEET
SIM SIMILAR
SL SLOPE
SL-DN SLOPE DOWN
SL-UP SLOPE UP
SOG SLAB-ON-GRADE
SP SHEET PILING
SPA SPACES, SPACE
SPECS SPECIFICATIONS
SQ SQUARE
SS STAINLESS STEEL
SSLT SHORT SLOTTED HOLE
STD STANDARD
STIFF STIFFENER
STL STEEL
STRUC STRUCTURAL
SYM SYMMETRICAL
T & B TOP AND BOTTOM
T/ TOP OF
T/GB TOP OF GRADE BEAM
TBS MECHANICAL TENSION BUTT SPLICE
TEMP TEMPERATURE
TF TRENCH FOOTING
THRU THROUGH
TRANS TRANSVERSE
TYP TYPICAL
UL UNDERWRITERS' LABORATORY INC.
UNO UNLESS NOTED OTHERWISE
UT ULTRA-SONIC TEST
VERT VERTICAL
W WIDE FLANGE
W/ WITH
W/O WITHOUT
WD WOOD
WF WALL FOOTING
WP WORK POINT
WWF WELDED WIRE FABRIC
STRUCTURAL ABBREVIATIONS
A/E ARCHITECT/ENGINEER
ACI AMERICAN CONCRETE INSTITUTE
ACP AUGER CAST PILE
ADDL ADDITIONAL
ADJ ADJACENT
AGGR AGGREGATE
AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION
ALT ALTERNATE
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
APPROX APPROXIMATE
AR ANCHOR ROD
ARCH ARCHITECTURAL
ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS
AWS AMERICAN WELDING SOCIETY
B/ BOTTOM OF
BAL BALANCE
BD BOARD
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BM BEAM
BOTT BOTTOM
BRG BEARING
BRKT BRACKET
BTWN BETWEEN
C STANDARD CHANNEL
CANT CANTILEVER
CC CENTER TO CENTER
CF COLD FORMED
CG CENTER OF GRAVITY
CIP CAST-IN-PLACE
CJ CONTROL JOINT OR CONSTRUCTION JOINT
CJP COMPLETE JOINT PENETRATION
CL CENTERLINE
CLR CLEARANCE, CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACTOR
CTR CENTER
CTRD CENTERED
CU FT CUBIC FEET
CU IN CUBIC INCH
CYD CUBIC YARD
CW CONCRETE WALL
DBL DOUBLE
DEG DEGREE
DEMO DEMOLITION, DEMOLISH
DEPT DEPARTMENT
DET DETAIL
DIA DIAMETER
DIAG DIAGONAL
DIAPH DIAPHRAGM
DIM DIMENSION
DN DOWN
DO DITTO
DP DRILLED PIER OR DEEP
DWG DRAWING
DWL DOWELS
EA EACH
EF EACH FACE
EJ EXPANSION JOINT
EL, ELEV ELEVATION
ELEC ELECTRICAL
ENCL ENCLOSURE
ENGR ENGINEER
EOD EDGE OF DECK
EOJ EDGE OF JOIST
EOS EDGE OF SLAB
EQ EQUAL
EQPT EQUIPMENT
ES EACH SIDE
EW EACH WAY
EX EXISTING
EXP EXPANSION
EXT EXTERIOR
FAB FROM ADJACENT BEAM
FD FLOOR DRAIN
FDN FOUNDATION
FIN FINISH
FLG FLANGE
FLR FLOOR
FS FOOTING STEP
FT FEET
FTG FOOTING
FTGD FOOTING DRAIN
FV FIELD VERIFY
GA GAUGE
GALV GALVANIZED
GB GRADE BEAM
GRND GROUND
GT GIRDER TRUSS
HAS, HS HEADED ANCHOR STUD
HK HOOK
HORIZ HORIZONTAL
HP HIGH POINT
HS HOLLOW STRUCTURAL SECTION
HT HIP TRUSS
HVAC HEATING, VENTILATION, AIR CONDITIONING
ID INSIDE DIAMETER
IF INSIDE FACE
IN INCH
INCL INCLUDE
INFO INFORMATION
INSUL INSULATION
INT INTERIOR
J/BRG JOIST BEARING
STRUCTURAL SHEET LIST
SHEET NUMBER SHEET NAME
SI001 STRUCTURAL ABBREVIATIONS
SI002 STRUCTURAL GENERAL NOTES
SI003 LOAD MAPS AND DESIGN DATA
SB101 FOUNDATION PLAN
SB102 SLAB ON GRADE PLAN
SB501 FOUNDATION SECTIONS AND DETAILS
SF101 ROOF FRAMING PLAN
SF201 BUILDING ELEVATIONS
SF202 BUILDING ELEVATIONS
SF501 FRAMING SECTIONS AND DETAILS
SF901 ISOMETRIC VIEWS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
B
IM
/2
V A
W e s t P a lm
B e a c h
E H
R M
I n fr a s tr u c tu re U p g ra d e s D e s ig n /2
.1
S v
.r v t
/2
/2
:4
:5
P
M
SI002
STRUCTURAL GENERAL NOTES
10360 Ellison Circle
Omaha, NE 68134
402.991.5520 specializedeng.com
1221 N. Pennsylvania St.
Indianapolis, IN 46202
317.800.6388 guidondesign.com
ELETRONIC HEALTH RECORD
MODERNIZATION (EHRM)
INFRASTRUCTURE UPGRADES
WEST PALM BEACH, FL
548-22-700
03/31/2023 LKL ADK
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
GENERAL
THE STRUCTURE HAS BEEN DESIGNED FOR THE IN-SERVICE LOADS ONLY. THE METHODS, MEANS, PROCEDURES, AND SEQUENCES OF CONSTRUCTION ARE THE RESPONSIBILITY OF THE CONTRACTOR. THE STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THE BUILDING IS COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES AND SEQUENCE TO INSURE SAFETY OF THE BUILDING AND ITS COMPONENTS DURING ERECTION. THIS INCLUDES THE ADDITION OF
NECESSARY SHORING, SHEETING, TEMPORARY BRACING, GUYS, TIEDOWNS, ETC.
THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH CIVIL, ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING
DRAWINGS AND SPECIFICATIONS.
THE GENERAL NOTES ON THE DRAWINGS ARE TO BE USED IN CONJUNCTION WITH THE FULL WRITTEN MATERIAL SPECIFICATIONS FOR THE PROJECT. IF A DISCREPANCY OCCURS BETWEEN THE NOTES AND THE FULL SPECIFICATIONS, THE MORE STRINGENT
REQUIREMENT SHALL APPLY.
NO PENETRATIONS THROUGH STRUCTURAL ELEMENTS, OTHER THAN THOSE SHOWN ON THE DRAWINGS, SHALL BE MADE WITHOUT
THE APPROVAL OF THE STRUCTURAL ENGINEER.
CONTRACTOR TO COORDINATE ALL EQUIPMENT, ROOF DRAINS, CHASES, AND OTHER ITEMS CONNECTED TO THE STRUCTURE BEFORE
FABRICATION BEGINS.
CONCRETE MIX DESIGN SUBMITTAL
THE CONTRACTOR SHALL SUBMIT FOR THE REVIEW OF THE STRUCTURAL ENGINEER A MIX DESIGN FOR EACH PROPOSED CLASS OF CONCRETE. EACH MIX DESIGN SHALL BE IDENTIFIED BY A MIX NUMBER OR OTHER UNIQUE IDENTIFICATION. THE CONTRACTOR SHALL NOT VARY FROM THE MIX DESIGNS NOR USE ANY CONCRETEOTHER THAN THE APPROVED MIX DESIGNS WITHOUT THE APPROVAL OF THE STRUCTURAL ENGINEER. MIX DESIGN SUBMITTALS SHALL INCLUDE THE FOLLOWING INFORMATION:
1. MIX DESIGN NUMBER OR UNIQUE IDENTIFICATION AND INTENDED LOCATION OF PLACEMENT.
2. CEMENT TYPE, PROPORTION AND NAME OF MANUFACTURER.
3. FLY ASH PROPORTION (WHEN USED), LABORATORY ANALYSIS CERTIFICATION, AND NAME AND LOCATION OF SUPPLIER.
4. COURSE AGGREGATE PROPORTION, GRADATION REPORT, NAME AND LOCATION OF SUPPLIER.
5. FINE AGGREGATE PROPORTION, GRADATION REPORT, NAME AND LOCATION OF SUPPLIER.
6. MIXING WATER PROPORTION AND SOURCE.
7. ADMIXTURE DOSAGES, PRODUCT NAME(S) AND MANUFACTURER NAME(S).
8. FIBER REINFORCEMENT DOSAGE (WHEN USED), PRODUCT NAME AND MANUFACTURER NAME.
9. DESIGN 28-DAY COMPRESSIVE STRENGTH (F'C).
10. DESIGN SLUMP RANGE.
11. DESIGN AIR-ENTRAINMENT (FOR CONCRETE REQUIRING ENTRAINED AIR).
12. STATISTICAL ANALYSIS OF LABORATORY STRENGTH TEST DATA IN ACCORDANCE WITH "STANDARD DEVIATION"
DETERMINATION OUTLINED IN ACI 318.
SHOP DRAWING SUBMITTALS
THE CONTRACTOR SHALL PREPARE DETAILED SHOP DRAWINGS TO ENABLE HIM TO FABRICATE, ERECT AND CONSTRUCT ALL PARTS OF THE WORK IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS. THESE SHOP DRAWINGS WILL BE REVIEWED FOR GENERAL COMPLIANCE WITH THE DESIGN INTENT ONLY. THE CONTRACTOR IS RESPONSIBLE FOR ALL DIMENSIONS, ACCURACY AND FIT OF WORK.
ALL SHOP DRAWINGS SHALL BE REVIEWED BY THE CONTRACTOR PRIOR TO SUBMITTAL TO THE STRUCTURAL ENGINEER. DRAWINGS
SUBMITTED WITHOUT CONTRACTOR'S REVIEW WILL BE RETURNED UNCHECKED.
SUBMIT ELECTRONIC VERSIONS OF SHOP DRAWINGS. SUBMIT SHOP DRAWINGS IN PDF FORMAT.
SUBMIT SHOP DRAWINGS FOR EACH OF THE FOLLOWING ITEMS:
1. CONCRETE REINFORCEMENT
2. STRUCTURAL STEEL (INCLUDING DESIGN CALCULATIONS SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE
WHERE THE PROJECT IS CONSTRUCTED FOR ALL CONNECTIONS NOT SPECIFICALLY DETAILED ON THE DRAWINGS)
3. STEEL DECK
PRODUCT DATA SUBMITTALS
THE CONTRACTOR SHALL SUBMIT FOR APPROVAL PRODUCT DATA FOR THE SPECIFIC ITEMS LISTED BELOW. CONTRACTOR SHALL NOT USE PRODUCTS OTHER THAN THOSE SUBMITTED WITHOUT THE APPROVAL OF THE STRUCTURAL ENGINEER.
MANUFACTURER'S TRADE NAMES AND NUMBERS USED HEREIN ARE ONLY TO IDENTIFY COLORS, FINISHES, TEXTURES, AND PATTERNS AS A BASIS OF DESIGN. PRODUCTS OF AUTHORIZED EQUAL MANUFACTURER'S EQUIVALENT TO COLORS, FINISHES, TEXTURES, AND PATTERNS OF MANUFACTURERS LISTED THAT MEET REQUIREMENTS OF TECHNICAL SPECIFICATIONS IN EVERY RESPECT MAY BE ACCEPTABLE WITH SUBMITTAL OF A COMPLETED SUBSTITUTION REQUEST CONTAINING ALL PRODUCT DATA, TESTING AND ACTUAL
SAMPLES, AND UPON APPROVAL IN WRITING BY CONTRACTING OFFICER.
SUBMIT ELECTRONIC VERSIONS OF PRODUCT DATA IN PDF FORMAT TO THE STRUCTURAL ENGINEER AND COR FOR REVIEW.
1. FIBER REINFORCEMENT FOR CONCRETE
2. CONCRETE REINFORCEMENT
3. DIAMOND PLATE DOWELS FOR SLABS ON GRADE
4. CONCRETE CURING COMPOUND
5. CONCRETE JOINT SEALANT
6. WATER STOPS
7. EXPANSION ANCHORS
8. ADHESIVE ANCHORS
9. NON-SHRINK GROUT
FOUNDATIONS
FOUNDATION EXCAVATIONS AND SOIL RELATED WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE GEOTECHNICAL REPORT
NUMBER 2073502 PREPARED BY TTL ASSOCIATES DATED AUGUST 15 2022.
FOUNDATIONS HAVE BEEN DESIGNED BASED ON ASSUMED ALLOWABLE NET BEARING PRESSURE OF 3,000 PSF. CONTRACTOR SHALL ENGAGE A LICENSED GEOTECHNICAL ENGINEER TO REVIEW THE SOIL CONDITIONS AT THE SITE AS NECESSARY TO CONFIRM THE ALLOWABLE CAPACITIES PRIOR TO PLACEMENT OF THE FOUNDATIONS. CONFIRMATION OF THE ACCEPTABILITY OF THE SOILS SHALL
BE REPORTED IN WRITING TO THE STRUCTURAL ENGINEER.
IF ACTUAL ALLOWABLE CAPACITIES ARE FOUND TO BE LESS THAN THE ASSUMED VALUES, THE CONTRACTOR SHALL NOTIFY THE STRUCTURAL ENGINEER IMMEDIATELY AND SHALL NOT PROCEED WITH FOUNDATION CONSTRUCTION WITHOUT REVIEW BY THE
STRUCTURAL ENGINEER.
FOUNDATIONS AND SOILS RELATED WORK SHALL BE INSPECTED BY A LICENSED GEOTECHNICAL ENGINEER. WRITTEN FIELD REPORTS
SHALL BE FORWARDED TO THE STRUCTURAL ENGINEER AS SOON AS THEY BECOME AVAILABLE.
FOUNDATION CONDITIONS NOTED DURING CONSTRUCTION, WHICH DIFFER FROM THOSE DESCRIBED IN THE GEOTECHNICAL REPORT, SHALL BE REPORTED TO THE STRUCTURAL ENGINEER AND GEOTECHNICAL ENGINEER BEFORE FURTHER CONSTRUCTION IS
ATTEMPTED.
EXCAVATIONS FOR SHALLOW FOUNDATIONS SHALL BE CLEANED AND HAND TAMPED TO UNIFORM SURFACE AND SHALL BE PROTECTED
AND MAINTAINED UNIFORM UNTIL CONCRETE IS PLACED.
CONCRETE
REINFORCED CONCRETE HAS BEEN DESIGNED IN ACCORDANCE WITH THE BUILDING CODE REQUIREMENTS FOR STRUCTURAL
CONCRETE (ACI 318) AND COMMENTARY (ACI 318R).
MIXING, TRANSPORTING, AND PLACING OF CONCRETE SHALL CONFORM TO THE LATEST EDITION OF THE SPECIFICATIONS FOR STRUCTURAL CONCRETE (ACI 301). READY-MIXED CONCRETE SHALL CONFORM TO THE REQUIREMENTS OF ASTM C94. IN CASE OF A
DISCREPANCY, THE PLANS AND SPECIFICATIONS SHALL GOVERN.
CEMENT SHALL CONFORM TO ASTM C150, TYPE I, UNO.
FLY ASH SHALL CONFORM TO ASTM C618, CLASS C OR F. THE RATIO OF THE AMOUNT (BY WEIGHT) OF FLY ASH TO TOTAL
CEMENTITIOUS MATERIALS IN THE MIX SHALL NOT EXCEED 25 PERCENT.
NORMAL WEIGHT AGGREGATES SHALL CONFORM TO ASTM C33.
WATER-REDUCING ADMIXTURES SHALL CONFORM TO ASTM C494.
AIR-ENTRAINING ADMIXTURES SHALL CONFORM TO ASTM C260 AND SHALL BE CERTIFIED BY THE MANUFACTURER TO BE COMPATIBLE
WITH OTHER ADMIXTURES.
CALCIUM CHLORIDE ADMIXTURES OR ADMIXTURES CONTAINING MORE THAN 0.1 PERCENT CHLORIDE IONS SHALL NOT BE USED.
IN COLD WEATHER CONDITIONS, MIXING, PLACING, FINISHING, CURING AND PROTECTION OF CONCRETE SHALL BE PERFORMED IN
ACCORDANCE WITH THE LATEST EDITION OF ACI 306R, COLD WEATHER CONCRETING.
IN HOT WEATHER CONDITIONS, MIXING, PLACING, FINISHING, CURING AND PROTECTION OF CONCRETE SHALL BE PERFORMED IN
ACCORDANCE WITH THE LATEST EDITION OF ACI 305R, HOT WEATHER CONCRETING.
USE OF CONSTRUCTION JOINTS AT LOCATIONS OTHER THAN THOSE INDICATED ON THE DRAWINGS SHALL BE SUBMITTED TO THE
STRUCTURAL ENGINEER FOR REVIEW.
SLUMP FOR PUMPED CONCRETE SHALL BE MEASURED AT POINT OF DISCHARGE.
NORMAL WEIGHT CONCRETE SHALL BE USED IN THE FOLLOWING AREAS AND SHALL
HAVE THE PROPERTIES AS SHOWN BELOW:
FOUNDATIONS
1. COMPRESSIVE STRENGTH (28 DAYS): 4000 PSI
2. MAXIMUM SLUMP: 4 INCHES
3. MINIMUM CEMENTITIOUS MATERIALS CONTENT: 470 LB./CU. YD. (USE TYPE II SULFATE RESISTANT CEMENT)
4. MAXIMUM SLUMP FOR CONCRETE CONTAINING HIGH-RANGE WATER-REDUCING ADMIXTURE: 8 INCHES (AFTER ADMIXTURE IS
ADDED TO CONCRETE WITH 2 TO 4 INCH SLUMP).
5. MAXIMUM WATER/CEMENTITIOUS MATERIALS RATIO: 0.48
6. MAXIMUM COARSE AGGREGATE SIZE: 1 1/2 INCHES
7. AIR CONTENT: N/A
FOUNDATION WALLS
1. COMPRESSIVE STRENGTH (28 DAYS): 4000 PSI
2. MAXIMUM SLUMP: 4 INCHES
3. MINIMUM CEMENTITIOUS MATERIALS CONTENT: 470 LB./CU. YD. (USE TYPE II SULFATE RESISTANT CEMENT)
4. MAXIMUM SLUMP FOR CONCRETE CONTAINING HIGH-RANGE WATER-REDUCING ADMIXTURE: 8 INCHES (AFTER ADMIXTURE IS
ADDED TO CONCRETE WITH 2 TO 4 INCH SLUMP).
5. MAXIMUM WATER/CEMENTITIOUS MATERIALS RATIO: 0.48
6. MAXIMUM COARSE AGGREGATE SIZE: 1 INCH
7. AIR CONTENT: N/A
RETAINING WALLS AND CURBS/SIDEWALKS/SLABS EXPOSED TO DE-ICERS
1. COMPRESSIVE STRENGTH (28 DAYS): 4000 PSI
2. MAXIMUM SLUMP: 4 INCHES
3. MINIMUM CEMENTITIOUS MATERIALS CONTENT: 517 LB./CU. YD. (USE TYPE II SULFATE RESISTANT CEMENT)
4. MAXIMUM SLUMP FOR CONCRETE CONTAINING HIGH-RANGE WATER-REDUCING ADMIXTURE: 8 INCHES (AFTER ADMIXTURE IS
ADDED TO CONCRETE WITH 2 TO 4 INCH SLUMP).
5. MAXIMUM WATER/CEMENTITIOUS MATERIALS RATIO: 0.45
6. MAXIMUM COARSE AGGREGATE SIZE: 1 INCH
7. AIR CONTENT: 6.0% +/- 1%
SLABS ON GRADE
1. COMPRESSIVE STRENGTH (28 DAYS): 4000 PSI
2. MAXIMUM SLUMP: 4 INCHES
3. MINIMUM CEMENTITIOUS MATERIALS CONTENT: 470 LB./CU. YD. (USE TYPE II SULFATE RESISTANT CEMENT)
4. MAXIMUM SLUMP FOR CONCRETE CONTAINING HIGH-RANGE WATER-REDUCING ADMIXTURE: 8 INCHES (AFTER ADMIXTURE IS
ADDED TO CONCRETE WITH 2 TO 4 INCH SLUMP).
5. MAXIMUM WATER/CEMENTITIOUS MATERIALS RATIO: 0.48
6. MAXIMUM COARSE AGGREGATE SIZE: 1 INCH
7. AIR CONTENT: 6% +/- 1%
8. HIGH RANGE WATER REDUCING ADMIXTURE AND FIBER REINFORCING REQUIRED
SLABS ON STEEL DECK
1. COMPRESSIVE STRENGTH (28 DAYS): 4000 PSI
2. MAXIMUM SLUMP: 4 INCHES
3. MINIMUM CEMENTITIOUS MATERIALS CONTENT: 470 LB./CU. YD.
4. MAXIMUM SLUMP FOR CONCRETE CONTAINING HIGH-RANGE WATER-REDUCING ADMIXTURE: 8 INCHES (AFTER ADMIXTURE IS
ADDED TO CONCRETE WITH 2 TO 4 INCH SLUMP).
5. MAXIMUM WATER/CEMENTITIOUS MATERIALS RATIO: 0.48
6. MAXIMUM COARSE AGGREGATE SIZE: 1 INCH
7. AIR CONTENT: N/A
CONCRETE SLABS ON GRADE
SLABS ON GRADE SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE LATEST EDITION OF THE GUIDE FOR CONCRETE FLOOR AND
SLAB CONSTRUCTION (ACI 302.1R).
PLACE CONCRETE IN A MANNER SO AS TO PREVENT SEGREGATION OF THE MIX. DELAY FLOATING AND TROWELING OPERATIONS UNTIL THE CONCRETE HAS LOST SURFACE WATER SHEEN OR ALL FREE WATER. DO NOT SPRINKLE FREE CEMENT ON THE SLAB SURFACE.
PROVIDE CURING OF CONCRETE SLABS IMMEDIATELY AFTER FINISHING USING A SPRAYED ON DISSIPATING-RESIN LIQUID CURING COMPOUND CONFORMING TO ASTM C309, UNLESS NOTED OTHERWISE. ALL SCUFFS OR ABRASIONS TO THE CURING MEMBRANE SHALL BE RECOATED DAILY. OTHER CURING METHODS MAY BE USED WITH APPROVAL BY THE STRUCTURAL ENGINEER.
SLABS ON GRADE SHALL BE PLACED TO ACHIEVE THE FOLLOWING MINIMUM TOLERANCES:
OVERALL VALUES: FF = 25
LOCAL VALUES: FF = 20
THE MINIMUM LOCAL AREA SHALL BE ANY BAY DEFINED BY COLUMN LINES.
UNLESS SHOWN OR NOTED OTHERWISE, PROVIDE CONTROL OR CONSTRUCTION JOINTS IN SLABS-ON-GRADE AT A MAXIMUM SPACING OF 36 TIMES THE SLAB THICKNESS. PROVIDE JOINTS AT ALL COLUMN LOCATIONS. LOCATE JOINTS TO ELIMINATE RE-ENTRANT CORNERS AND TO CREATE SQUARE OR RECTANGULAR SECTIONS WITH MAXIMUM LONG SIDE TO SHORT SIDE RATIO OF 1.5 TO 1.
CONTROL JOINTS IN SLABS ON GRADE SHALL NOT RECEIVE JOINT FILLER MATERIAL UNLESS NOTED OTHERWISE.
CONCRETE SLABS ON METAL DECK
UNLESS INDICATED OTHERWISE ON THE DRAWINGS, CONCRETE SLABS ON METAL DECK SHALL BE PLACED AS REQUIRED TO MAINTAIN
A CONSTANT SLAB [THICKNESS].
CONTRACTOR SHALL ALLOW FOR THE DEFLECTION OF THE FLOOR ASSEMBLY DUE TO THE WET WEIGHT OF THE CONCRETE WHEN CALCULATING CONCRETE QUANTITIES AND SHALL INCLUDE THE COST OF ALL REQUIRED SLAB-ON-DECK CONCRETE IN THE BID PRICE.
PRIOR TO PLACEMENT OF CONCRETE SLABS ON METAL DECK, THE CONTRACTOR SHALL CAREFULLY REVIEW THE ELEVATIONS OF THE STRUCTURAL STEEL FRAMING, INCLUDING CAMBERED MEMBERS, FOR CONFORMANCE WITH THE CONSTRUCTION DOCUMENTS.
CONTRACTOR SHALL NOTIFY THE STRUCTURAL ENGINEER OF ANY DISCREPANCIES (SUCH AS IMPROPER CAMBER, IMPROPER STEEL ELEVATIONS, ETC.) IMMEDIATELY AND SHALL NOT BEGIN CONCRETE PLACEMENT WITHOUT PRIOR REVIEW BY THE STRUCTURAL
ENGINEER.
ACTUAL CONCRETE SLAB THICKNESS SHALL NOT BE LESS THAN THE INDICATED NOMINAL THICKNESS AT ANY LOCATION. IF ANY CONDITION IS DISCOVERED THAT WOULD PREVENT PLACEMENT OF CONCRETE TO THE NOMINAL THICKNESS; CONTRACTOR SHALL NOTIFY THE STRUCTURAL ENGINEER IMMEDIATELY AND SHALL NOT PROCEED WITH CONCRETE PLACEMENT WITHOUT PRIOR REVIEW
BY THE STRUCTURAL ENGINEER.
SLABS ON METAL DECK SHALL RECEIVE A SMOOTH TROWEL FINISH, AND BE PLACED TO ACHIEVE THE FOLLOWING MINIMUM
TOLERANCES:
OVERALL VALUES: FF = 25
LOCAL VALUES: FF = 20
PLACE CONCRETE IN A MANNER SO AS TO PREVENT SEGREGATION OF THE MIX. DELAY FLOATING AND TROWELING OPERATIONS UNTIL THE CONCRETE HAS LOST SURFACE WATER SHEEN OR ALL FREE WATER. DO NOT SPRINKLE FREE CEMENT ON THE SLAB SURFACE.
PROVIDE CURING OF CONCRETE SLABS IMMEDIATELY AFTER FINISHING USING A SPRAYED ON DISSIPATING-RESIN LIQUID CURING COMPOUND CONFORMING TO ASTM C309. ALL SCUFFS OR ABRASIONS TO THE CURING MEMBRANE SHALL BE RECOATED DAILY. OTHER
CURING METHODS MAY BE USED WITH APPROVAL BY THE STRUCTURAL ENGINEER.
REINFORCING STEEL
REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO ASTM A615 AND SHALL HAVE A MINIMUM YIELD STRENGTH OF 60,000
PSI.
REINFORCING BAR DETAILING, FABRICATING, AND PLACING SHALL CONFORM TO THE LATEST EDITION OF THE FOLLOWING STANDARDS:
ACI 301, ACI 315, ACI 318 AND ACI DETAILING MANUAL (SP66).
UNLESS A GREATER AMOUNT OF COVER IS INDICATED ON THE DRAWINGS, PROVIDE THE FOLLOWING MINIMUM CONCRETE COVER
OVER REINFORCEMENT AS FOLLOWS:
CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 3 INCHES
#6 BARS AND LARGER EXPOSED TO EARTH OR WEATHER: 2 INCHES
#5 BARS AND SMALLER EXPOSED TO EARTH OR WEATHER: 1-1/2 INCHES
BEAM AND COLUMN TIES, STIRRUPS AND SPIRALS: 1-1/2 INCHES
ELEVATED SLAB BARS NOT EXPOSED TO EARTH OR WEATHER: 3/4 INCH
REINFORCING STEEL SHALL NOT BE TACK WELDED, WELDED, HEATED OR CUT UNLESS INDICATED ON THE CONTRACT DOCUMENTS OR
APPROVED BY THE STRUCTURAL ENGINEER.
WHERE LAP SPLICE LENGTHS ARE NOT SHOWN OR NOTED, PROVIDE A CLASS "B" LAP.
ALL 90 DEGREE AND 180 DEGREE BENDS SHOWN ON THE DRAWINGS SHALL BE STANDARD HOOKS, UNLESS NOTED OTHERWISE.
PROVIDE CORNER BARS OF SAME SIZE AND SPACING AS HORIZONTAL BARS AT CORNERS OF ALL WALLS AND GRADE BEAMS. LAP
SPLICE CORNER BARS WITH STRAIGHT BARS.
UNLESS OTHERWISE SHOWN OR NOTED, PROVIDE 2-#6 BARS (ONE EACH FACE) AROUND UNFRAMED OPENINGS IN CONCRETE WALLS AND GRADE BEAMS. PLACE BARS PARALLEL TO THE SIDES OF THE OPENING AND EXTEND 24" BEYOND CORNERS.
WELDED WIRE FABRIC
WELDED WIRE FABRIC SHALL BE SMOOTH WIRE FABRIC CONFORMING TO ASTM A185. FABRIC SHALL BE SUPPLIED IN FLAT SHEETS AND
LAPPED A MINIMUM OF ONE SPACE PLUS 2 INCHES.
WELDED WIRE FABRIC SHALL BE PLACED AS FOLLOWS, UNLESS NOTED OTHERWISE:
SLABS ON METAL DECK: 3/4 INCH DOWN FROM TOP OF SLAB.
FIBER REINFORCEMENT
FIBER REINFORCEMENT SHALL BE 3/4" LONG, VIRGIN (NON-RECYCLED) NYLON OR POLYPROPYLENE FIBERS, INTRODUCED INTO THE CONCRETE MIX AT THE BATCH PLANT, IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. DOSAGE SHALL BE 1.5
POUNDS PER CUBIC YARD OF CONCRETE.
CONCRETE TESTING
MAKE ONE SET OF TEST CYLINDERS IN ACCORDANCE WITH ASTM C31 FOR EACH DAY'S POUR AND FOR EACH 100 CUBIC YARDS. EACH SET SHALL INCLUDE ONE SPECIMEN TESTED AT 7 DAYS, 2 SPECIMENS TESTED AT 28 DAYS AND ONE SPECIMEN RETAINED IN RESERVE TO BE TESTED AT THE DIRECTION OF THE STRUCTURAL ENGINEER. SPARE CYLINDER MAY BE DISCARDED 90 DAYS AFTER CASTING
UNLESS
DIRECTED OTHERWISE BY THE STRUCTURAL ENGINEER. THIS SET OF TEST CYLINDERS SHALL BE PROTECTED AGAINST FREEZING.
WHEN THE AMBIENT TEMPERATURE IS EXPECTED TO FALL BELOW 40 DEGREES DURING THE COURSE OF A CONCRETE POUR OR SUBSEQUENT CURING PROCESS, AN ADDITIONAL SET OF CONCRETE TEST CYLINDERS SHALL BE MADE AND TESTED. THESE CYLINDERS SHALL BE STORED IMMEDIATELY ADJACENT TO, AND CURED UNDER THE SAME CONDITIONS AS THE BUILDING CONCRETE. SPECIAL
CURING BOXES ARE NOT PERMITTED FOR THESE TEST CYLINDERS.
FORWARD COPIES OF TEST RESULTS TO THE ARCHITECT, STRUCTURAL ENGINEER, READY-MIX SUPPLIER AND CONTRACTOR WITHIN 24
HOURS AFTER TESTING.
EXPANSION ANCHORS
EXPANSION ANCHORS SHALL BE CARBON STEEL ANCHORS AS MANUFACTURED BY HILTI FASTENING SYSTEMS OR AN EQUIVALENT SUBSTITUTE APPROVED BY THE STRUCTURAL ENGINEER AND SHALL BE INSTALLED IN CONFORMANCE WITH THE MANUFACTURER'S
RECOMMENDATIONS.
EXPANSION ANCHORS SHALL NOT BE INSTALLED IN CONCRETE UNTIL IT HAS ATTAINED ITS SPECIFIED MINIMUM 28 DAY COMPRESSIVE
STRENGTH.
ADHESIVE ANCHORS
ADHESIVE ANCHORS SHALL BE HILTI "HIT HY200" FOR SOLID SUBSTRATE AND HILTI "HIT HY270" FOR HOLLOW SUBSTRATE OR AN EQUIVALENT SUBSTITUTE APPROVED BY THE STRUCTURAL ENGINEER, UNLESS NOTED OTHERWISE ON PLANS. ANCHORS SHALL BE INSTALLED IN CONFORMANCE WITH THE MANUFACTURER'S RECOMMENDATIONS BY INSTALLERS TRAINED BY THE MANUFACTURER'S
REPRESENTATIVE.
MINIMUM EMBEDMENT DEPTH SHALL BE 8 BOLT DIAMETERS UNLESS NOTED OTHERWISE.
NON-SHRINK GROUT
GROUT SHALL BE A NON-METALLIC, SHRINKAGE RESISTANT (WHEN TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ASTM C827 OR CRD-C621), PREMIXED, NON-CORROSIVE, NON-STAINING PRODUCT CONTAINING PORTLAND CEMENT, SILICA SANDS, SHRINKAGE COMPENSATING AGENTS AND FLUIDITY IMPROVING COMPOUNDS. GROUT SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH (F'C) OF
5,000 PSI IN 28 DAYS.
WATERSTOPS
SELF-EXPANDING STRIP WATER STOPS SHALL BE VOLCLAY WATERSTOP-RX 101 UNLESS NOTED OTHERWISE. INSTALL IN ACCORDANCE
WITH MANUFACTURER'S WRITTEN INSTRUCTIONS.
PVC WATERSTOPS
PROVIDE FACTORY MADE WATERSTOP FABRICATIONS FOR ALL CHANGES OF DIRECTION, INTERSECTIONS, AND TRANSITIONS LEAVING
ONLY STRAIGHT BUTT JOINT SPLICES FOR THE FIELD.
PROVIDE HOG RINGS OR GROMMETS SPACED AT 12 INCHES ON CENTER ALONG LENGTH OF WATERSTOP.
PROVIDE TEFLON COATED THERMOSTATICALLY CONTROLLED WATERSTOP SPLICING IRONS FOR FIELD BUTT SPLICES.
FIELD BUTT SPLICES SHALL BE HEAT FUSED WELDED USING A TEFLON COATED THERMOSTATICALLY CONTROLLED WATERSTOP SPLICING IRON AT APPROXIMATELY 380 DEGREES F. FOLLOW APPROVED MANUFACTURER RECOMMENDATIONS.
LAPPING OF WATERSTOP, USE OF ADHESIVES, OR SOLVENTS SHALL NOT BE ALLOWED.
CENTER WATERSTOP IN JOINT AND SECURE WATERSTOP IN CORRECT POSITION USING HOG RINGS OR GROMMETS SPACED AT 12 INCHES ON CENTER ALONG THE LENGTH OF THE WATERSTOP AND WIRE TIE TO ADJACENT REINFORCING STEEL.
MASTIC COATING
MASTIC COATING FOR PROTECTION OF INDICATED ITEMS SHALL BE BITUMASTIC 50 COAL TAR MASTIC BY CARBOLINE OR EQUIVALENT SUBSTITUTE APPROVED BY THESTRUCTURAL ENGINEER. INSTALL AT LOCATIONS INDICATED ON DRAWINGS.
UNLESS NOTED OTHERWISE, APPLY MASTIC TO A COATING THICKNESS OF 18 MILS. PROVIDE FULL COVERAGE OVER ITEMS INDICATED
TO RECEIVE COATING.
STRUCTURAL STEEL
STRUCTURAL STEEL DETAILING, FABRICATION AND ERECTION SHALL CONFORM TO THE ANSI/AISC 360 SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS, LATEST EDITION WITH AMENDMENTS, AND THE AISC 303 CODE OF STANDARD PRACTICE FOR
STEEL BUILDINGS AND BRIDGES, LATEST EDITION WITH AMENDMENTS.
STRUCTURAL STEEL WIDE FLANGE SHAPES SHALL CONFORM TO ASTM A992, 50 KSI.
STRUCTURAL STEEL PLATES AND ROLLED SHAPES OTHER THAN WIDE-FLANGE SHAPES SHALL CONFORM TO ASTM A36, UNLESS NOTED
OTHERWISE.
STRUCTURAL STEEL TUBING SHALL CONFORM TO ASTM A500, GRADE B.
ANCHOR RODS SHALL CONFORM TO ASTM F1554, GRADE 36, UNLESS NOTED OTHERWISE.
STEEL STUDS SHALL CONFORM TO ASTM A108.
BOLTED CONNECTIONS SHALL CONFORM TO THE SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS, APPROVED BY THE RESEARCH COUNCIL ON STRUCTURAL CONNECTIONS OF THE ENGINEERING FOUNDATION. BOLTED CONNECTIONS FOR STRUCTURAL STEEL MEMBERS SHALL BE MADE WITH 3/4" DIAMETER A325 BOLTS, UNLESS NOTED OTHERWISE.
BOLTED CONNECTIONS SHALL BE TIGHTENED TO THE SNUG TIGHT CONDITION, EXCEPT BOLTED CONNECTIONS IN BRACE ELEMENTS
ARE TO BE FULLY PRETENSIONED WITH CLASS A FAYING SURFACES.
WELDING PROCEDURES SHALL CONFORM TO THE LATEST EDITION OF THE AMERICAN WELDING SOCIETY'S STRUCTURAL WELDING
CODE FOR STEEL ANSI/AWS D1.1.
WELDED CONNECTIONS USING ASTM A992 STEEL AS A BASE METAL SHALL BE MADE WITH E70XX LOW HYDROGEN ELECTRODES.
UNLESS OTHERWISE SHOWN OR NOTED ON THE DRAWINGS, OTHER WELDED CONNECTIONS MAY BE MADE WITH STANDARD E70XX
ELECTRODES.
STRUCTURAL STEEL THAT RECEIVES FINISH PAINT SHALL BE SHOP-PRIMED WITH A RUST-INHIBITING PRIMER, UNLESS NOTED OTHERWISE ON THE DRAWINGS. CONTRACTOR SHALL VERIFY PRIMER IS COMPATIBLE WITH FINISH COAT SYSTEM SPECIFIED BY THE
ARCHITECT. COORDINATE FINISH PAINTING REQUIREMENTS WITH THE ARCHITECT.
STRUCTURAL STEEL THAT IS NOT EXPOSED IN THE FINISHED CONSTRUCTION AND DOES NOT RECEIVE FINISH PAINT SHALL NOT BE
SHOP-PRIMED, UNLESS NOTED OTHERWISE ON THE DRAWINGS.
STRUCTURAL STEEL NOTED TO BE GALVANIZED SHALL BE HOT-DIP GALVANIZED IN CONFORMANCE WITH ASTM A123.
DO NOT PAINT OR GALVANIZE THE FOLLOWING SURFACES:
1. SURFACES TO BE WELDED.
2. SURFACES TO RECEIVE BOLTED SLIP-CRITICAL CONNECTIONS.
3. SURFACES TO RECEIVE SHEAR STUD CONNECTIONS.
4. SURFACES TO RECEIVE SPRAYED-ON FIREPROOFING.
ALL ABRASIONS TO GALVANIZED SURFACES OR SURFACES TO RECEIVE AN ARCHITECTURAL FINISH COAT SHALL BE TOUCHED-UP AFTER ERECTION IS COMPLETE. FOR PAINTED STEEL, USE A PRIMER EQUIVALENT TO THE SHOP PAINT. FOR GALVANIZED STEEL, USE
A ZINC-RICH COLD-GALVANIZING PAINT.
DESIGN CONNECTIONS NOT SHOWN IN ACCORDANCE WITH THE ASD SPECIFICATION AND MANUAL OF STEEL CONSTRUCTION. UNLESS NOTED OTHERWISE ON THE DRAWINGS, DESIGN BEAM CONNECTIONS NOT SHOWN, TO SUPPORT A MINIMUM OF A 10 KIP SHEAR REACTION. PROVIDE NO LESS THAN 2 BOLTS IN ANY SINGLE LINE OF BOLTS, UNLESS SPECIFICALLY INDICATED ON THE DRAWINGS.
PROVIDE C8X13.7 FRAMED OPENINGS FOR ALL ROOF PENETRATIONS 12 INCHES OR LARGER ALONG ANY SIDE, UNLESS LARGER FRAMING IS INDICATED. REFER TO MECHANICAL AND PLUMBING DRAWINGS FOR PENETRATIONS. COORDINATE FRAMED OPENING SIZES
AND LOCATIONS WITH THE MECHANICAL AND PLUMBING CONTRACTORS.
GALVANIZE ALL EXPOSED STEEL.
COMPOSITE STEEL BEAMS
COMPOSITE BEAM SHEAR CONNECTORS SHALL BE NELSON STUD TYPE S3L AS MANUFACTURED BY THE NELSON STUD WELDING
COMPANY, OR AN EQUIVALENT SUBSTITUTE APPROVED BY THE STRUCTURAL ENGINEER.
STUDS SHALL BE MANUFACTURED OF COLD-DRAWN STEEL CONFORMING TO ASTM A108. STUDS SHALL BE 3/4" DIAMETER X 3" INCHES LONG @ 24" OC, UNLESS NOTED OTHERWISE. STUD DESIGN HAS BEEN BASED ON AN ULTIMATE SHEAR CAPACITY OF 17.7 KIPS PER
STUD.
COMPOSITE STEEL BEAMS HAVE BEEN DESIGNED TO ALLOW INSTALLATION OF THE SLAB CONCRETE IN AN UNSHORED CONDITION
UNLESS NOTED OTHERWISE.
STEEL ROOF DECK
PROVIDE AND ERECT STEEL DECK IN ACCORDANCE WITH THE LATEST EDITION OF THE STEEL DECK INSTITUTE'S SPECIFICATIONS AND
CODE OF STANDARD PRACTICE.
DECK MANUFACTURER SHALL PROVIDE ALL ROOF DECK ACCESSORIES, INCLUDING CLOSURES, SUPPLEMENTARY FRAMING, AND SUMP
PANS, WHETHER OR NOT SUCH ITEMS ARE DETAILED ON THE CONTRACT DOCUMENTS.
FASTEN ROOF DECK TO STEEL SUPPORTS AS INDICATED ON THE DRAWINGS. PERFORM WELDING IN ACCORDANCE WITH ANSI/AWS D1.3.
ROOF DECK SHALL BE INSTALLED IN A MINIMUM THREE SPAN CONDITION.
PROVIDE STEEL ROOF DECK WITH FINISH AS INDICATED ON THE DRAWINGS.
FLOOR LOAD SCHEDULE
A
B
TYP ROOF 10 NOTE 1
MECHANICAL
EQUIPMENT 5
- 20 (NR)
9 PSF BASE SNOW LOAD +
DRIFT
60 (NR)
MARK
DEAD LOAD
(PSF)
DESCRIPTION
SDL
OCCUPANCY/USE
POINT LOAD
(LBS)
DESCRIPTION LIVE LOAD
(PSF)
SNOW LOAD (PSF)
SDL LL SL
NOTE 1 -
NOTES:
1. SDL INDICATES SUPERIMPOSED DEAD LOAD AND IS DL IN ADDITION TO THE SELF WEIGHT OF THE PRIMARY STRUCTURAL SYSTEM.
2. (NR) INDICATES NON-REDUCIBLE LIVE LOAD.
9 PSF BASE SNOW LOAD +
DRIFT
A
B
A A
A
A
B
SF501
SF201
6'
6'
6' - 0"
9' - 3" 9' - 3"
6' - 0"
31 PSF
31 PSF
9 PSF
9 PSF
9 PSF
40 PSF
31 PSF
9 PSF
40 PSF
31 PSF
9 PSF 9 PSF
WALL WIND PRESSURE
ZONE 4 (PSF)
NOTES:
1. VAULES OF UPLIFT HAVE BEEN CALCULATED IN ACCORDANCE WITH ASCE 7-22 CHAPTER 30
SECTION 30.3.2
ZONE 5 (PSF)PRESSURE
TYPE
SUCTION
INWARD
PRESSURE
46 52
52 67
ROOF WIND UPLIFT SCHEDULE
0-60 31
HEIGHT
(FT)
ZONE 1' (PSF)
NOTES:
1. VAULES OF UPLIFT HAVE BEEN CALCULATED IN ACCORDANCE WITH ASCE 7-22 CHAPTER 30
SECTION 30.3.2
2. VALUES OF UPLIFT ARE DUE TO WIND LOADING ONLY AND DO NOT ACCOUNT FOR OTHER TYPES
OF GRAVITY LOADING
ZONE 1 (PSF)
ZONE 2 (PSF)
ZONE 3 (PSF)
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
B
IM
/2
V A
W e s t P a lm
B e a c h
E H
R M
I n fr a s tr u c tu re U p g ra d e s D e s ig n /2
.1
S v
.r v t
/2
/2
:4
:5
P
M
SI003
LOAD MAPS AND DESIGN DATA
10360 Ellison Circle
Omaha, NE 68134
402.991.5520 specializedeng.com
1221 N. Pennsylvania St.
Indianapolis, IN 46202
317.800.6388 guidondesign.com
ELETRONIC HEALTH RECORD
MODERNIZATION (EHRM)
INFRASTRUCTURE UPGRADES
WEST PALM BEACH, FL
548-22-700
03/31/2023 LKL ADK
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
DESIGN DATA
THE BUILDING STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE WITH THE 2021 INTERNATIONAL BUILDING CODE.
SEE LOAD MAPS FOR FLOOR LOADING CRITERIA.
SNOW LOAD DESIGN DATA
1. GROUND SNOW LOAD (PG) = 7 PSF
2. LOW-SLOPE ROOF SNOW LOAD (PF) = 9 PSF
3. SNOW EXPOSURE FACTOR (CE) = 0.9
4. THERMAL FACTOR (CT) = 1.2
5. SNOW LOAD IMPORTANCE FACTOR (IS) = 1.2
WIND LOAD DESIGN DATA
1. BASIC WIND SPEED (3-SECOND GUST) = 185 MPH
2. WIND EXPOSURE = B
3. WIND DESIGN PRESSURE (P) = VARIES WITH HEIGHT AND LOCATION
EARTHQUAKE DESIGN DATA
1. SHORT PERIOD SPECTRAL RESPONSE (SS) = 0.05
2. 1-SECOND SPECTRAL RESPONSE (S1) = 0.025
3. SEISMIC IMPORTANCE FACTOR (IE) = 1.5
4. OCCUPANCY CATEGORY = IV
5. SEISMIC DESIGN CATEGORY = A
6. SITE CLASSIFICATION = D
7. SHORT PERIOD SPECTRAL RESPONSE COEFFICIENT (SDS) = 0.053
8. 1-SECOND SPECTRAL RESPONSE COEFFICIENT (SD1) = 0.04
9. BASIC STRUCTURAL SYSTEM / SEISMIC RESISTING SYSTEM: A3 - ORDINARY REINFORCED CONCRETE SHEAR WALLS
10. ANALYSIS PROCEDURE UTILIZED = EQUIVALENT LATERAL FORCE PROCEDURE
11. RESPONSE MODIFICATION COEFFICIENT (R) = 4
12. SEISMIC RESPONSE COEFFICIENT (CS) = 0.02
THE BUILDING STRUCTURE, COMPONENTS, AND ANY DELEGATED EXTERIOR FACADE DESIGN SHALL BE DESIGNED FOR BLAST LOADING ACCORDING TO THE CRITERIA SET FORTH IN THE LATEST EDITION OF THE DEPARTMENT OF VETERAN AFFAIRS PHYSICAL SECURITY
DESIGN MANUAL FOR MISSION CRITICAL/LIFE SAFETY FACILITIES
SCALE: 3/16" = 1'-0"SI003
2 LOAD MAP
L
L3
C
C
R 20.00'
R 50.00'
X
S1
1+
0+00
DUCT BANK - (ee)
DUCT BANK - (ff)
1+71.8
0+00.0
1+00.0
2+00.0
3+00.0
0+00.0
R30'
39.65'
.7
R 3'
17.5'
R3'
.1
R3'26.1'
R 3'
27.63'
6.9'
9'
18'
.5
4'
10.7'
8'
7'
8.75'
52.49'
R30'
20'
7'21'
38.5'
120'
8'
R50'
.2
5'
5'
0'
SF201
SF202
SF201
SF202
CW15
WF36
WF36
CW15
W F
C
W
W F
C
W
A
B
9" 6" 140' - 6" 6"
9" 141' - 6"
9" 6"
1"
3'
6" 9"
SB501
3' - 4" 14' - 7 29/128" 31' - 4 1/2"
1' - 4 35/128"3' - 4" 7' - 7" 6' - 4" 14' - 9" 3' - 4"
C W
W
F
9"
9"
9"
9"
FOOTING STEP
FOOTING STEP
SB501
SB501
T/FTG = 99'- 0"
T/FTG = 99'- 0"
T/FTG = 99'- 0"
T/FTG = 99'- 0"T/FTG = 96'- 3"
T/FTG = 96'- 3"
SB501
SB501
SB501
CW12
C W
CW12
C W
C W
W F
WF36
WF36
W F
W F
10” CONCRETE RETAINING WALL.
COORDINATE EXACT
LOCATIONS/LENGTHS WITH CIVIL
AND ARCH DRAWINGS
T/WALLS = 108'- 0"
T Y
P
1'
T Y
P
2'
C W
CW10
C W
CW10
WF52
W F
WF52
W F
C W
W F
10” CONCRETE RETAINING WALL.
COORDINATE EXACT LOCATION AND
LENGTHS WITH CIVIL AND ARCH
DRAWINGS 22' - 0" 17' - 6"
6'
59' - 1 1/2"
8'
6' - 0 1/2"
SB501
SB501
SB501
SIM
SF201
40' - 6"11' - 8 7/8"
12" WIDE X 4" BOXOUT
FOR ARCHITECTURAL
SCUPPERS
11' - 6"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
B
IM
/2
V A
W e s t P a lm
B e a c h
E H
R M
I n fr a s tr u c tu re U p g ra d e s D e s ig n /2
.1
S v
.r v t
/2
/2
:4
:5
P
M
SB101
FOUNDATION PLAN
10360 Ellison Circle
Omaha, NE 68134
402.991.5520 specializedeng.com
1221 N. Pennsylvania St.
Indianapolis, IN 46202
317.800.6388 guidondesign.com
ELETRONIC HEALTH RECORD
MODERNIZATION (EHRM)
INFRASTRUCTURE UPGRADES
WEST PALM BEACH, FL
548-22-700
03/31/2023 LKL ADK
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
SCALE: 1/8" = 1'-0"SB101
1 FOUNDATION PLAN
NOTES:
1. REFERENCE FINISH FLOOR ELEVATION = 100' - 0". USGS ELEVATION = 17.5'
2. SEE SI002 SHEETS FOR GENERAL PROJECT INFORMATION
3. SEE PLAN FOR T/FTG
4. T/WALL (CW15) = 100'-0" UNO. FOR T/WALL (CW12) SEE SHEET SF101
5. T/RETAINING WALL (CW10)= 99’-6” UNO.
WALL FOOTING SCHEDULE
MARK
FOOTING SIZE
REINFORCEMENT
WIDTH DEPTH
WF36 3' - 0" 2' - 0" (5) #6 BARS LONGITUDINAL TOP AND BOTTOM, #4 BARS @ 18" OC TRANSVERSE TOP AND BOTTOM
WF52 4' - 4" 1' - 6" (5) #6 BARS LONGITUDINAL TOP AND BOTTOM, #5 BARS @ 18" OC TRANSVERSE TOP AND BOTTOM
CONCRETE WALL SCHEDULE
MARK WALL THICKNESS
HORIZONTAL REINF VERTICAL REINF
INSIDE FACE OUTSIDE FACE INSIDE FACE OUTSIDE FACE
CW10 10" #5 @ 18" OC #5 @ 18" OC #5 @ 18" OC #5 @ 18" OC
CW12 1' - 0" #6 @ 12" OC #6 @ 12" OC #6 @ 12" OC #6 @ 12" OC
CW15 1' - 3" #6 @ 12" OC #6 @ 12" OC #6 @ 12" OC #6 @ 12" OC
N
SCALE: 1" = 20'-0"SB101
2 FOUNDATION OVERLAY
SF201
SF202
SF201
SF202
141' - 6"
6" 6"
6" 6"
6" 6" 140' - 6" 6"
6"
CJ
CJ
CJ
CJ
CJ
CJ CJ CJ CJ CJ CJ CJ CJ CJ CJ CJ CJ
CW12
C W
CW12
C W
1' - 10" 3' - 4" 7' - 7 35/128" 6' - 4" 14' - 9" 3' - 4"
3'
6" SLAB ON GRADE WITH FIBER
REINFORCING OVER
ARCHITECTURAL UNDERSLAB
VAPOR BARRIER AND 6"
COMPACTED STRUCTURAL FILL
A
B
3'
/4
3'
/4
3'
5'
/1 6"
9"
9"
9"9"9"
HOUSEKEEPING PAD.
COORDINATE EXACT SIZE AND
LOCATION WITH MEP AND
ARCHITECTURE.
22' - 6" 18' - 0"
40' - 6"
4'
0"
4'
4'
0"
4'
0"
4'
SB501
SB501
SB501
HOUSEKEEPING PAD.
COORDINATE EXACT SIZE AND
LOCATION WITH ELECTRICAL
AND ARCHITECTURE.
COORDINATE W/ CIVIL
12' - 5 7/8"
6" SLAB ON GRADE WITH FIBER
MESH REINFORCING OVER
ARCHITECTURAL UNDERSLAB
VAPOR BARRIER AND COMPACTED
STRUCTURAL FILL
CJ
CJ
CJ
CJ
C O
O R
D
IN
A T
E W
/ C
IV
IL
/4
HOUSEKEEPING PAD.
COORDINATE EXACT SIZE AND
LOCATION WITH ELECTRICAL
AND ARCHITECTURE.
SF201
12" WIDE X 4" BOXOUT FOR
ARCHITECTURAL SCUPPERS.
COORDINATE ELEVATION WITH
EXTERIOR SIDEWALKS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
B
IM
/2
V A
W e s t P a lm
B e a c h
E H
R M
I n fr a s tr u c tu re U p g ra d e s D e s ig n /2
.1
S v
.r v t
/2
/2
:4
:5
P
M
SB102
SLAB ON GRADE PLAN
10360 Ellison Circle
Omaha, NE 68134
402.991.5520 specializedeng.com
1221 N. Pennsylvania St.
Indianapolis, IN 46202
317.800.6388 guidondesign.com
ELETRONIC HEALTH RECORD
MODERNIZATION (EHRM)
INFRASTRUCTURE UPGRADES
WEST PALM BEACH, FL
548-22-700
03/31/2023 LKL ADK
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
SCALE: 1/8" = 1'-0"SB102
1 SLAB ON GRADE PLAN
N
NOTES:
1. REFERENCE FINISH FLOOR ELEVATION = 100' - 0". USGS ELEVATION = 17.5'
2. SEE SI002 SHEETS FOR GENERAL PROJECT INFORMATION
3. CONTRACTOR TO VERIFY AND COORDINATE ALL LOCATIONS AND SIZES OF DOOR OR MECHANICAL OPENINGS
WITH ARCHITECTURE AND MEP DRAWINGS
OPENING PER ARCH
WALL - SEE PLAN
TYPICAL SLAB REINFORCING @ ALL
OVERHEAD DOORS, MANDOORS
AND WINDOWS (WHERE
APPLICABLE
#4 BAR x OPENING + 3'-0" @
SLAB MID DEPTH
1 - #4 BAR x 2'-6" @ SLAB MID DEPTH
1/
2" C
LR
NOTE:
PROVIDE CORNER BARS AT ALL INTERSECTIONS, SAME SIZE AND
SPACING AS HORIZONTAL REINFORCEMENT
JAMB SHOWN
AT HEAD PROVIDE (2) #5
AND EXTEND 2'-0" EITHER
SIDE OF OPENING
INTERSECTION JAMB & HEAD CORNER
LA
P
S P
LI
C
E C
LA
S
S B
ALT DIR
OF BEND
(2) #5 JAMB BARS
EXTEND FULL HEIGHT
OF WALL OPENING
CORNER BARS TO MATCH TYPICAL
HORIZONTAL WALL REINFORCEMENT SIZE AND
SPACING
LA
P
S P
LI
C
E
C
LA
S S
B
TYP WALL REINFTYP WALL REINF
CONTROL JOINT
CONSTRUCTION JOINT
P
LA
N
S E
E
T H
IC
K
N E
S S
1/ x S
LA
B
1/4" ± SAWED JOINT
COAT OR WRAP TO
PREVENT BONDSMOOTH DOWEL BAR
PER TABLE
DOWEL SIZE AND SPACING
DOWEL
DIAMETER
IN
SLAB
DEPTH
TOTAL DOWEL
LENGTH
DOWEL SPACING CENTER
TO CENTER
IN IN IN
3/44 16 24
3/45-6 16 12
1 18 12
1 1/4 18 12
7-8
9-11
T H
IC
K
N E
S S
1/
X S
LA
B
T/SLAB
1/2" ISOLATION JOINT
SLAB PER PLAN
WALL PER PLAN AND SCHEDULE
PER PLAN
PER PLAN
T/SLAB
PER PLAN
T/FTG
PER PLAN
FOOTING PER PLAN AND SCHEDULE
3'
PROVIDE ROUGHENED
SURFACE W/ 1/4"
AMPLITUDE
1 (MAX.)
ALTER EXCAVATION
LIMITS
1' - 6"
CLASS B TENSION
LAP PER SCHEDULE
EQ. EQ
BARS TO MATCH
FOOTING REINF. SIZE
AND SPACING
F S
INDICATES
FOOTING STEP
F S
F S
4'-0" MIN.
2' -0
M
A X
1' - 7"
CLASS B TENSION
LAP PER SCHEDULE
T/FTG
PER PLAN
T/FTG
PER PLAN
M A
X
2'
MIN
2' - 0"
T/SLAB
PER PLAN
T/FTG
PER PLAN
SLAB PER PLAN
FOOTING PER PLAN AND SCHEDULE
(4) #6 BARS
#6 @ 12"
PER PLAN
EXTERIOR SLAB PER
CIVIL DRAWINGS
3/4" SMOOTH DOWELS X 18" LONG @ 12" OC W/
GREASED END ON EXTERIOR PORTION
PROVIDE ROUGHENED SURFACE W/
1/4" AMPLITUDE
1/2" ISOLATION JOINT
SLAB PER PLANWALL PER PLAN AND SCHEDULE
T/SLAB
PER PLAN
T/FTG
PER PLAN
FOOTING PER PLAN AND SCHEDULE
PROVIDE ROUGHENED
SURFACE W/ 1/4" AMPLITUDE
SLAB PER PLAN
4"
HOUSEKEEPING PAD.VERIFY
EXTENTS OF HOUSEKEEPING PAD
WITH MEP DRAWINGS AND
EQUIPMENT MANUFACTURER
ROUGHEN SLAB PRIOR TO
PLACING HOUSEKEEPING PAD
1/2" ISOLATION JOINT
SLAB PER PLAN
WALL PER PLAN AND SCHEDULE
T/SLAB
PER PLAN
T/FTG
PER PLAN
FOOTING PER PLAN AND SCHEDULE
PROVIDE ROUGHENED SURFACE
W/ 1/4" AMPLITUDE
EXTERIOR SIDEWALK.
REFERENCE CIVIL AND
ARCHITECTURE DRAWINGS
REBAR PER SCHEDULE
REBAR PER SCHEDULE
T/WALL
PER PLAN
T/FTG
PER PLAN
1' - 0"
2' - 6"
1'
PER PLAN
PROVIDE ROUGHENED
SURFACE W/ 1/4"
AMPLITUDE
PROVIDE ROUGHENED
SURFACE W/ 1/4"
AMPLITUDE
M
IN
1'
C
LR3"
SEAL VOID WITH
PERMANENT
COMPRESSIBLE FILLER
PROVIDE 2-#5 x 4'-0" AT
PENETRATION, CENTERED
SLEEVE FOR CONDUIT, 2"
LARGER THAN CONDUIT
DIAMETER, CENTERED
PROVIDE ADDITIONAL REINF
TO MATCH WALL FOOTING
REINF (LAP 24")
3"
CENTERLINE OF OPENING
WALL
FOOTING
M
IN
2'
NOTES:
1. SEE MEP AND FIRE PROTECTION DRAWINGS FOR LOCATIONS AND SIZE OF
PENETRATIONS.
2. DETAIL SHOWN IS FOR MAXIMUM OF 12" DIA PIPE. FOR LARGER SIZE, CONTACT
STRUCTURAL ENGINEER PRIOR TO CONSTRUCTION.
NOTE:
WHERE VERTICAL REINFORCING IS INTERRUPTED BY THE OPENING, HALF
OF THE INTERRUPTED STEEL SHALL BE ADDED EACH SIDE OF THE
OPENING. USE FULL LENGTH BARS. IF BARS CANNOT BE PLACED AS
DETAILED, REPLACE THE 1'-6" EXTENSION WITH 6" AND A STANDARD HOOK.
1'- 6"
1'- 6"
2" CL.
2 - #5 x LENGTH VARIES
(1 EACH FACE)
COORDINATE SLEEVES
WITH MECHANICAL.
PROVIDE LINK-SEAL FOR
ALL PENETRATIONS
THRU BASEMENT WALLS
NOTE:
COORDINATE FINAL LOCATION OF PIPE PENETRATIONS WITH MECHANICAL
CONTRACTOR BEFORE INSTALLATION OF THE REINFORCING.
THIS DETAIL APPLIES TO ALL ROUND AND ELLIPTICAL OPENINGS IN
CONCRETE WALLS, UNLESS OTHERWISE NOTED ON THE PLANS.
.0
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
B
IM
/2
V A
W e s t P a lm
B e a c h
E H
R M
I n fr a s tr u c tu re U p g ra d e s D e s ig n /2
.1
S v
.r v t
/2
/2
:4
:5
P
M
SB501
FOUNDATION SECTIONS AND
DETAILS10360 Ellison Circle
Omaha, NE 68134
402.991.5520 specializedeng.com
1221 N. Pennsylvania St.
Indianapolis, IN 46202
317.800.6388 guidondesign.com
ELETRONIC HEALTH RECORD
MODERNIZATION (EHRM)
INFRASTRUCTURE UPGRADES
WEST PALM BEACH, FL
548-22-700
03/31/2023 LKL ADK
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
SCALE: 3/4" = 1'-0"SB501
1 ADDITIONAL REINFORCING AT DOORS AND WINDOWS
SCALE: 3/4" = 1'-0"SB501
2 CORNER BAR DETAILS
SCALE: 3/4" = 1'-0"SB501
3 TYPICAL SLAB ON GRADE JOINTS
SCALE: 3/4" = 1'-0"SB501
6 FOUNDATION SECTION
SCALE: 3/4" = 1'-0"SB501
4 TYPICAL STEPPED FOOTING
SCALE: 3/4" = 1'-0"SB501
8 FOUNDATION SECTION
SCALE: 3/4" = 1'-0"SB501
7 FOUNDATION SECTION
SCALE: 1" = 1'-0"SB501
10 HOUSEKEEPING PAD
SCALE: 3/4" = 1'-0"SB501
5 FOUNDATION SECTION
SCALE: 3/4" = 1'-0"SB501
9 FOUNDATION SECTION
SCALE: 3/4" = 1'-0"SB501
11 FOUNDATION SECTION
SCALE: 3/4" = 1'-0"SB501
12 C.I.P. WALL ROUND OPENING
SF202
142' - 0"
W
X
C
=3 /4
(6
2)
W
X
C
=3 /4
(1
W
X
C
=3 /4
(7
5)
W
X
C
=3 /4
(7
5)
W
X
C
=3 /4
(7
5)
W
X
C
=3 /4
(7
5)
6" 6"
1' - 0"
30 EQ SPACES
1' - 0"
6" 6"
6"
6"
W
X
C
=3 /4
(7
5)
W
X
C
=3 /4
(7
5)
W
X
C
=3 /4
(7
5)
W
X
C
=3 /4
(7
5)
W
X
C
=3 /4
(7
5)
W
X
C
=3 /4
(7
5)
W
X
C
=3 /4
(6
2)
W
X
C
=3 /4
(6
2)
W
X
C
=3 /4
(6
2)
W
X
C
=3 /4
(6
2)
W
X
C
=3 /4
(6
2)
W
X
C
=3 /4
(6
2)
W
X
C
=3 /4
(6
2)
W
X
C
=3 /4
(6
2)
W
X
C
=3 /4
(6
2)
W
X
C
=3 /4
(6
2)
W
X
C
=3 /4
(6
2)
W
X
C
=3 /4
(6
2)
W
X
C
=3 /4
(6
2)
W
X
C
=3 /4
(6
2)
W
X
C
=3 /4
(6
2)
W
X
C
=3 /4
(6
2)
W
X
C
=3 /4
(6
2)
W
X
C
=3 /4
(6
2)
W
X
C
=3 /4
(6
2)
CW12
CW12
C W
C W
A
B
SF501
T/STEEL = 117'-9" ALONG GRIDLINE
T/STEEL = 118'-9 1/2" ALONG GRIDLINE
SF501
SF501
SF501
SIM
SF501
SF501
C W
SF101
E
Q U
A L
S P
A C
E S
2'
1"
SF501
AREA DENOTES PRE-ENGINEERED METAL CANOPY.
COORDINATE WITH ARCHITECTURE DRAWINGS, TYP
SF501
4'
C8X13.7
C8X13.7
W
X
T /S
T E
E L
3/
4" C
E N
T E
R E
D O
V E
R D
O O
R F
O R
O H
D O
O R
S U
P P
O R
T
A S
R E
Q U
IR
E
D
0"
INDICATES L4X4X3/8 CROSS BRACING
C8X13.7
C8X13.7
HSS6X4X1/2
H S
S 6X
4X 1/
H
S S
6X 4X
1/
HSS6X4X1/2 HSS6X4X1/2 HSS6X4X1/2 HSS6X4X1/2
H S
S 6X
4X 1/
H
S S
6X 4X
1/
HSS6X4X1/2
HSS5X
5X 5/
HSS5X
5X
5/
HSS5X
5X
5/
HSS5X
5X
5/
HSS5X
5X
5/
HSS5X
5X
5/
HSS5X
5X
5/
HSS5X
5X
5/
HSS5X
5X
5/
HSS5X
5X
5/
(2 ) E
Q U
A L
S P
A C
E S
SF501
TYP
SF501
HSS6X4X1/2HSS6X4X1/2
HSS6X4X1/2 HSS6X4X1/2HSS6X4X1/2 HSS6X4X1/2
H S
S 6X
4X 1/
H
S S
6X 4X
1/
H S
S 6X
4X 1/
H
S S
6X 4X
1/
SF501
SIM
W12X14
HSS6X4X1/2
W12X14
PER ROOF PLAN PER ROOF PLAN
0"
0"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
B
IM
/2
V A
W e s t P a lm
B e a c h
E H
R M
I n fr a s tr u c tu re U p g ra d e s D e s ig n /2
.1
S v
.r v t
/3
/2
:0
:1
A
M
SF101
ROOF FRAMING PLAN
10360 Ellison Circle
Omaha, NE 68134
402.991.5520 specializedeng.com
1221 N. Pennsylvania St.
Indianapolis, IN 46202
317.800.6388 guidondesign.com
ELETRONIC HEALTH RECORD
MODERNIZATION (EHRM)
INFRASTRUCTURE UPGRADES
WEST PALM BEACH, FL
548-22-700
03/31/2023 LKL ADK
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
SCALE: 3/16" = 1'-0"SF101
1 ROOF FRAMING PLAN
N
NOTES:
1. REFERENCE FINISH FLOOR ELEVATION = 100' - 0". SEE CIVIL FOR USGS ELEVATIONS
2. T/WALL = 120'-10 1/2"
3. CONTRACTOR TO VERIFY AND COORDINATE ALL LOCATIONS AND SIZES OF DOOR OR MECHANICAL OPENINGS
WITH ARCHITECTURE AND MEP DRAWINGS
SCALE: 1/4" = 1'-0"SF101
2 SCREENWALL FRAMING PLAN
NOTES:
1. REFERENCE FINISH FLOOR ELEVATION = 100' - 0". SEE CIVIL FOR USGS ELEVATIONS
2. SEE ROOF FRAMING PLAN FOR LOCATION DIMENSIONS
3. T/HSS STEEL = 120'-4" AND 124'-10"
4. CONTRACTOR TO VERIFY AND COORDINATE ALL LOCATIONS AND SIZES OF DOOR OR MECHANICAL OPENINGS
WITH ARCHITECTURE AND MEP DRAWINGS
N
T/WALL
PER PLAN
51' - 0"
WALL JOINTS AT EQUAL SPACING NOT EXCEED 32'-0"
13' - 1 1/4" 4' - 0" 3' - 10 3/4" 10' - 0" 5' - 5" 4' - 0"
8'
/2
8'
/2
T/WALL
PER PLAN
T/FTG
PER PLAN
1/ 2"
1 2
T/WALL
PER PLAN
51' - 0"
WALL JOINTS AT EQUAL SPACING NOT EXCEED 32'-0"
30' - 3" 3' - 4"
SF501
8'
T/WALL
PER PLAN
T/FTG
PER PLAN
T/FTG
PER PLAN
RETAINING WALL AND WALL
FOOTING. SEE FOUNDATION
PLAN AND CIVIL DRAWINGS
FOR MORE INFORMATION
T/WALL
PER PLAN
T/WALL
PER PLAN
T/FTG
PER…