Attachment_10_-_BEPA_Roof_Replacement_Drawings_REV.pdf

PDF 5 MB Posted

Attached to
National Park Service (NPS) - National Capital Are
Solicitation number
140P3021R0024
Issued by

About this file

This solicitation package describes requirements for the rehabilitation of the Belmont-Paul Women's Equality National Monument located in Washington, DC. Work includes interior and exterior repairs, structural upgrades, fire suppression and mechanical/electrical/plumbing system improvements. Interior repairs include plaster repair, painting, and new finishes/lighting. Exterior repairs include painting, window restoration, and dormer element restoration. Structural work includes foundation installation, framing additions, and stair/landing repairs. Fire suppression upgrades and HVAC/ductwork installations are planned. Site work such as drain replacement and paver restoration is also specified. Hazardous material abatement is required. An optional roof replacement may be included. The pre-bid meeting is scheduled for July 30, 2021. The solicitation package is available on SAM.gov as of July 27, 2021.

View the file

Other files

File Type Posted
Amendment_0001_-_Questions_and_Answers_0001.pdf PDF
Attachment_15_-_Amendment_0001_-_BEPA_Phase_2_Final_Calculations_0001.pdf PDF
Attachment_16_-_Amendment_0001_-_BEPA_Phase_2_Final_Product_Data_0001.pdf PDF
Amendment_0001_-_photos_0001.docx DOCX document
Sol_140P3021R0024_Amd_0001.pdf PDF
Attachment_3_-_BEPA_Phase_2_Final_Submittal_Log.pdf PDF
Attachment_2_-_BEPA_Phase_2_Final_Drawing_-_Part_3_49-56.pdf PDF
Attachment_2_-_BEPA_Phase_2_Final_Drawing_-_Part1_1-40.pdf PDF
Attachment_11_-_DB_Wage_Determinations_-_Heavy_-_DC20210001_-_7022021.pdf PDF
Attachment_5_-_BEPA_Pre-alt_Hazardous_Materials_Survey_Report.pdf PDF
Attachment_1_-_BEPA_Phase_2_Final_Specifications_120720_KB.pdf PDF
Attachment_8_-_DCRA_Permit_BCIV2000025-EXT-3__06-02-2021.pdf PDF
Attachment_12_-_DB_Wage_Determinations_-_Building_-_DC20210002_-_6182021.pdf PDF
Attachment_7_-_DCRA_Permit_BCIV1800159_APPROVED_PLAN_SET_BEPA_E_S_Plan.pdf PDF
Attachment_13_-_Proposal_Submission_Package.docx DOCX document
Attachment_2_-_BEPA_Phase_2_Final_Drawing_-_Part_4_57-103.pdf PDF
Attachment_4_-_BEPA_Phase_II_Renovation_Collections_to_Protect.pdf PDF
Attachment_6_-_BEPA_CCTV_Report_FINAL.pdf PDF
Attachment_9_-_Updated_Roofing_Specifactions__-_final_7_27_2021.pdf PDF
Sol_140P3021R0024.pdf PDF
Attachment_2_-_BEPA_Phase_2_Final_Drawing_-_Part_2_41_48.pdf PDF
Attachment_14_-_Pre-Proposal_Site_Visit_Agenda.doc DOC document
Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

U S

C a p i t o l U

S

C a p i t o l U

S

C a p i t o l U

S

C a p i t o l

B e l m o n t P a u l

S i t e

REHABILITATION OF THE BELMONT-PAUL

WOMEN'S EQUALITY NATIONAL MONUMENT

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

UNITED STATES DEPARTMENT OF THE INTERIOR

AutoCAD SHX Text

NATIONAL PARK SERVICE

AutoCAD SHX Text

NATIONAL MALL AND MEMORIAL PARKS (NAMA)

AutoCAD SHX Text

WASHINGTON, D.C.

AutoCAD SHX Text

VICINITY MAP

AutoCAD SHX Text

COVER SHEET

AutoCAD SHX Text

GENERAL NOTES

AutoCAD SHX Text

1. ALL ARCHITECTURAL & ENGINEERING WORK SHALL CONFORM TO THE LATEST EDITION OF THE INTERNATIONAL ALL ARCHITECTURAL & ENGINEERING WORK SHALL CONFORM TO THE LATEST EDITION OF THE INTERNATIONAL BUILDING CODE (IBC) & FAMILY OF INTERNATIONAL CODES. WORK SHALL CONFORM TO THE LIFE SAFETY CODE. 2. ALL NEW WORK SHALL COMPLY WITH ADAABAAG, THE AMERICANS WITH DISABILITIES ACT (ADA 28 CFR PART 36) ALL NEW WORK SHALL COMPLY WITH ADAABAAG, THE AMERICANS WITH DISABILITIES ACT (ADA 28 CFR PART 36) ACCESSIBILITY GUIDELINES FOR BUILDINGS AND FACILITIES; ARCHITECTURAL BARRIERS ACT (ABA) ACCESSIBILITY GUIDELINES WHERE APPLICABLE. 3. UTILITY MARKING: NOTIFY MISS UTILITY OR OTHER QUALIFIED UTILITY LOCATING SERVICE 48 HOURS PRIOR TO UTILITY MARKING: NOTIFY MISS UTILITY OR OTHER QUALIFIED UTILITY LOCATING SERVICE 48 HOURS PRIOR TO COMMENCEMENT OF ON-SITE WORK. CONTRACTOR(S) SHALL BE RESPONSIBLE FOR CONTACTING MISS UTILITY OR PRIVATE UTILITY LOCATING SERVICE, IN ADVANCE, FOR MARKING OF ALL UNDERGROUND UTILITIES WITHIN WORK ZONES WHERE DIGGING, TEST PITS, PROBES, ETC. ARE ANTICIPATED. 1-800-252-7777 OR 811. 4. NOTIFY COR A MINIMUM OF 72 HOURS IN ADVANCE OF BORING, DIGGING OR ANY GROUND DISTURBING ACTIVITIES. A NOTIFY COR A MINIMUM OF 72 HOURS IN ADVANCE OF BORING, DIGGING OR ANY GROUND DISTURBING ACTIVITIES. A NPS ARCHEOLOGIST AND/OR CULTURAL RESOURCE MANAGER MAY BE INVOLVED TO OBSERVE WORK IN PROGRESS. 5. ALL WORK SHALL BE IN ACCORDANCE WITH STANDARD OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) ALL WORK SHALL BE IN ACCORDANCE WITH STANDARD OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) GUIDELINES AND REGULATIONS. 6. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL CONSTRUCTION PERMITS. SEE SPECIFICATION SECTION 011100, CONTRACTOR SHALL OBTAIN AND PAY FOR ALL CONSTRUCTION PERMITS. SEE SPECIFICATION SECTION 011100, SUMMARY OF WORK FOR LIST OF APPLICABLE PERMITS AND DOCUMENTATION. 7. ASBESTOS-CONTAINING MATERIALS (ACM'S) HAVE BEEN IDENTIFIED WITHIN THE PROJECT AREA. COORDINATE WITH ASBESTOS-CONTAINING MATERIALS (ACM'S) HAVE BEEN IDENTIFIED WITHIN THE PROJECT AREA. COORDINATE WITH OTHER TRADES AS REQUIRED TO ENSURE WORKER SAFETY AND PROPER HANDLING OF ACM'S. 8. LEAD BASED PAINT (LBP) AND LEAD-CONTAINING PAINT (LCP) HAS BEEN IDENTIFIED WITHIN THE PROJECT AREA. LEAD BASED PAINT (LBP) AND LEAD-CONTAINING PAINT (LCP) HAS BEEN IDENTIFIED WITHIN THE PROJECT AREA. COORDINATE LEAD MANAGEMENT WITH OTHER TRADES AS REQUIRED TO ENSURE WORKER SAFETY. LEAD SAFE WORK PRACTICES SHALL BE EMPLOYED PER THE OSHA LEAD IN CONSTRUCTION STANDARD (29 CFR 1626.62).

AutoCAD SHX Text

PMIS #310286

AutoCAD SHX Text

WASHINGTON, D.C.

AutoCAD SHX Text

144 CONSTITUTION AVE, NE WASHINGTON, DC

AutoCAD SHX Text

REHABILITATE BELMONT-PAUL MONUMENT

AutoCAD SHX Text

NATIONAL MALL AND MEMORIAL PARKS (NAMA)

AutoCAD SHX Text 11/30/20

AutoCAD SHX Text

NATIONAL PARK SERVICE - NATIONAL CAPITAL REGION

AutoCAD SHX Text

DESIGN AND PROJECT MANAGEMENT

AutoCAD SHX Text

UNITED STATES

AutoCAD SHX Text

OF

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DWG. NO.

AutoCAD SHX Text

DATE

AutoCAD SHX Text

DEPARTMENT OF THE INTERIOR

AutoCAD SHX Text

SUB SHEET NUMBER

AutoCAD SHX Text

TITLE OF DRAWING

AutoCAD SHX Text Mark

AutoCAD SHX Text Sheet

AutoCAD SHX Text Initial

AutoCAD SHX Text Date

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DESIGNED

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

CHECKED

AutoCAD SHX Text

TITLE OF PROJECT

AutoCAD SHX Text

NAME OF PARK

AutoCAD SHX Text

LOCATION WITHIN PARK

AutoCAD SHX Text

BEPS ROOF CD PHASE II

AutoCAD SHX Text

RJ

AutoCAD SHX Text

RJ

AutoCAD SHX Text

CD

AutoCAD SHX Text PMIS No.

AutoCAD SHX Text 310286

AutoCAD SHX Text

AutoCAD SHX Text

%%UINDEX OF DRAWINGS

AutoCAD SHX Text

SHEET #

AutoCAD SHX Text

SUB-SHEET

AutoCAD SHX Text

SHEET TITLE

AutoCAD SHX Text 1 OF 14 2 OF 14 3 OF 14 4 OF 14 5 OF 14 6 OF 14 7 OF 14 8 OF 14 9 OF 14 10 OF 14 11 OF 14 12 OF 14 13 OF 14 14 OF 14

AutoCAD SHX Text

A000 A001 AD101 AD102 A100 A101 A102 A200 A201 A202 A203 A204 A205 A300

AutoCAD SHX Text COVER SHEET GENERAL NOTES & ABBREVIATIONS & SYMBOLS SITE PLAN DEMO ROOF PLAN - SOUTH END DEMO ROOF PLAN - NORTH END NEW ROOF PLAN - SOUTH END NEW ROOF PLAN - NORTH END SOUTH ELEVATION EAST ELEVATION - SOUTH END EAST ELEVATION - NORTH END NORTH ELEVATION WEST ELEVATION - SOUTH END WEST ELEVATION - NORTH END EXTERIOR DETAILS

AutoCAD SHX Text

AutoCAD SHX Text Constitution Ave, NE

AutoCAD SHX Text 2nd Street, NE

AutoCAD SHX Text

PROJECT LOCATION

AutoCAD SHX Text A000

GENERAL NOTES

AutoCAD SHX Text

1. THESE NOTES ARE TO BE READ IN CONJUNCTION WITH ANY THESE NOTES ARE TO BE READ IN CONJUNCTION WITH ANY WRITTEN SPECIFICATIONS AND THESE DRAWINGS. IN THE EVENT OF CONFLICT BETWEEN THE INFORMATION ON THE DRAWINGS AND THE SPECIFICATIONS, THE MOST STRINGENT REQUIREMENTS SHALL GOVERN. 2. THIS IS A HISTORICALLY SIGNIFICANT BUILDING WHICH IS LISTED THIS IS A HISTORICALLY SIGNIFICANT BUILDING WHICH IS LISTED ON THE NATIONAL REGISTER OF HISTORIC PLACES, AND IS DESIGNATED AS A NATIONAL HISTORIC LANDMARK AND A NATIONAL MONUMENT. THE BUILDING SHALL BE TREATED RESPECTFULLY. EXISTING CONDITIONS ARE TO BE CAREFULLY RESPECTED AND NO MATERIAL OR BUILDING ELEMENT SHALL BE REMOVED OR DISFIGURED UNLESS SPECIFICALLY INDICATED ON THE DRAWINGS, SPECIFIED HEREIN, OR DIRECTED BY THE COR. 3. THIS BUILDING CONTAINS SENSITIVE HISTORIC SPACES, FEATURES, THIS BUILDING CONTAINS SENSITIVE HISTORIC SPACES, FEATURES, AND FINISHES THAT MUST BE PROTECTED AT ALL TIMES DURING CONSTRUCTION. REFER TO SPECIFICATION SECTION 013591, "HISTORIC TREATMENT PROCEDURES" FOR TEMPORARY PROTECTION REQUIREMENTS. 4. THE CONTRACTOR SHALL DOCUMENT EXISTING CONDITIONS PRIOR THE CONTRACTOR SHALL DOCUMENT EXISTING CONDITIONS PRIOR TO BEGINNING THE WORK. THE CONTRACTOR SHALL PROVIDE PROTECTION AND TAKE PRECAUTION TO AVOID DAMAGE TO ADJACENT ITEMS, MATERIALS AND FINISHES. DEMOLITION AND NEW CONSTRUCTION SHALL PROCEED WITH CARE SO AS TO NOT DAMAGE HISTORIC FINISHES. ANY EXISTING ITEMS OR FINISHES DAMAGED BY THE CONTRACTOR SHALL BE RESTORED TO THEIR ORIGINAL CONDITION OR BETTER UNLESS AT NO ADDITIONAL COST TO THE GOVERNMENT. 5. CONTRACTOR SHALL USE ALL REASONABLE AND CUSTOMARY CARE CONTRACTOR SHALL USE ALL REASONABLE AND CUSTOMARY CARE TO VERIFY ALL EXISTING CONDITIONS IN FIELD. CONTRACTOR SHALL NOTIFY COR IMMEDIATELY OF INCONSISTENCIES BETWEEN THESE DRAWINGS AND ACTUAL CONDITIONS BEFORE PROCEEDING WITH CONSTRUCTION OR DEMOLITION. INFORMATION CONTAINED ON THESE DRAWINGS WITH REGARD TO EXISTING CONDITIONS OF CONSTRUCTION IS PROVIDED FOR THE CONVENIENCE OF THE CONTRACTOR IN EXECUTING THE WORK. THESE DRAWINGS HAVE BEEN BASED ON DRAWINGS FROM THE HISTORIC STRUCTURE REPORT AND FURTHER SUPPLEMENTED BY FIELD MEASUREMENT AND OBSERVATIONS. 6. THE FOLLOWING WORDS AND PHRASES ARE DEFINED AS FOLLOWS: THE FOLLOWING WORDS AND PHRASES ARE DEFINED AS FOLLOWS: 6.1. EXISTING TO REMAIN: LEAVE EXISTING ITEMS THAT ARE NOT EXISTING TO REMAIN: LEAVE EXISTING ITEMS THAT ARE NOT TO BE REMOVED, AND THAT ARE NOT OTHERWISE INDICATED TO BE SALVAGED OR REINSTALLED. 6.2. REMOVE: DETACH ITEMS FROM EXISTING CONSTRUCTION AND REMOVE: DETACH ITEMS FROM EXISTING CONSTRUCTION AND DISPOSE OF THEM OFF-SITE UNLESS INDICATED TO BE SALVAGED OR REINSTALLED. 6.3. REMOVE AND SALVAGE: DETACH ITEMS FROM EXISTING REMOVE AND SALVAGE: DETACH ITEMS FROM EXISTING CONSTRUCTION, IN A MANNER TO PREVENT DAMAGE, AND DELIVER TO OWNER READY FOR REUSE. 6.4. REPLACE: TO REMOVE, DUPLICATE, AND REINSTALL ENTIRE REPLACE: TO REMOVE, DUPLICATE, AND REINSTALL ENTIRE ITEM WITH NEW MATERIAL. THE ORIGINAL ITEM IS THE PATTERN FOR CREATING DUPLICATES UNLESS OTHERWISE INDICATED. 6.5. REINSTALL: TO PROTECT REMOVED OR DISMANTLED ITEM, REINSTALL: TO PROTECT REMOVED OR DISMANTLED ITEM, REPAIR AND CLEAN IT AS INDICATED FOR REUSE, AND REINSTALL IT IN ORIGINAL POSITION, OR WHERE INDICATED. 6.6. PROVIDE: FURNISH AND INSTALL NEW ITEM. PROVIDE: FURNISH AND INSTALL NEW ITEM. 6.7. COMPLETE/LY: 100% OF THE IDENTIFIED SURFACE PLANE: COMPLETE/LY: 100% OF THE IDENTIFIED SURFACE PLANE: WALL TO WALL OR CORNER TO CORNER. 6.8. PAINT: PREPARE SURFACE AS SPECIFIED (IE. REMOVE PAINT: PREPARE SURFACE AS SPECIFIED (IE. REMOVE MISCELLANEOUS HARDWARE, PATCH MINOR HOLES AND CRACKS, SEAL STAINS, ETC.) AND PAINT. 6.9. REPAIR: TO CORRECT DAMAGE AND DEFECTS, RETAINING REPAIR: TO CORRECT DAMAGE AND DEFECTS, RETAINING EXISTING MATERIALS, FEATURES, AND FINISHES WHILE EMPLOYING AS LITTLE NEW MATERIAL AS POSSIBLE. THIS INCLUDES PATCHING, PIECING-IN, SPLICING, CONSOLIDATING, OR OTHERWISE REINFORCING OR UPGRADING MATERIALS. 6.10. TYPICAL: THE IDENTIFIED TREATMENT IS TO BE APPLIED AT TYPICAL: THE IDENTIFIED TREATMENT IS TO BE APPLIED AT ADDITIONAL LOCATIONS THROUGHOUT THE DRAWING WHERE SIMILAR CONDITIONS EXIST. 6.11. SIMILAR: THE REFERENCED DETAIL MUST BE MODIFIED TO SIMILAR: THE REFERENCED DETAIL MUST BE MODIFIED TO MEET THE REQUIREMENTS OF THIS SPECIFIC LOCATION. CONTRACTOR IS TO SUBMIT MARKED DETAIL SKETCH FOR REVIEW BY THE COR. 6.12. COR: THE GOVERNMENT CONTRACTING OFFICER OR A COR: THE GOVERNMENT CONTRACTING OFFICER OR A REPRESENTATIVE DESIGNATED BY THE CONTRACTING OFFICER. 7. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR SEQUENCING ALL THE CONTRACTOR IS SOLELY RESPONSIBLE FOR SEQUENCING ALL WORK AND FOR COORDINATION OF ALL SUBCONTRACTORS. REINSTALLATION OF ANY WORK INSTALLED THAT HAS NOT BEEN COORDINATED AND HAS TO BE REINSTALLED SHALL BE DONE AT THE CONTRACTOR'S EXPENSE. 8. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE WORK THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE WORK OF ALL TRADES TO ASSURE PROPER REMOVAL OF EXISTING CONSTRUCTION AND THE INSTALLATION OF ALL NEW CONSTRUCTION. 9. PARKING AREAS, DRIVEWAYS, SIDEWALKS, AND SURFACED STREETS PARKING AREAS, DRIVEWAYS, SIDEWALKS, AND SURFACED STREETS SHALL BE MAINTAINED IN A CLEAN CONDITION, ADEQUATE MEANS SHALL BE PROVIDED TO CLEAN TRUCKS AND OTHER EQUIPMENT USING SURFACED STREETS AND PARKING AREAS. 10. THE CONTRACTOR'S EQUIPMENT AND STAGING SHALL NOT BLOCK THE CONTRACTOR'S EQUIPMENT AND STAGING SHALL NOT BLOCK BUILDING EXITS NOR LIMIT ACCESS TO THE STRUCTURE BY THE FIRE DEPARTMENT IN THE EVENT OF AN EMERGENCY. 11. PARKING OF CONTRACTOR VEHICLES AND MATERIALS DELIVERIES PARKING OF CONTRACTOR VEHICLES AND MATERIALS DELIVERIES AREA STRICTLY LIMITED TO 4 CURB PERMITTED PARKING SPACES ON SECOND STREET NE. 12. THE EXISTING BUILDING ENVELOPE SHALL BE MAINTAINED IN A THE EXISTING BUILDING ENVELOPE SHALL BE MAINTAINED IN A WATERTIGHT CONDITION AT ALL TIMES DURING CONSTRUCTION. 13. ALL DIMENSIONS TO NEW CONSTRUCTION ARE TO FACE OF ALL DIMENSIONS TO NEW CONSTRUCTION ARE TO FACE OF STRUCTURE. ALL DIMENSIONS TO EXISTING CONSTRUCTION ARE TO FINISH FACE UNLESS OTHERWISE NOTED. NOTES TO ALIGN NEW CONSTRUCTION WITH EXISTING CONDITIONS ARE FROM FACE OF EXISTING FINISH TO FACE OF NEW FINISH. 14. THESE DRAWINGS ARE NOT TO BE SCALED FOR THE PURPOSE OF THESE DRAWINGS ARE NOT TO BE SCALED FOR THE PURPOSE OF LAYING OUT DEMOLITION OR NEW WORK. USE FIGURED DIMENSIONS ONLY. 15. LEAD PAINT WILL BE ENCOUNTERED IN THE WORK, A REPORT ON LEAD PAINT WILL BE ENCOUNTERED IN THE WORK, A REPORT ON THE PRESENCE OF LEAD PAINT IS INCLUDED WITH THE CONTRACT DOCUMENTS FOR REVIEW AND USE BY THE CONTRACTOR. 16. ASBESTOS CONTAINING MATERIALS (ACMs) WILL BE ENCOUNTERED ASBESTOS CONTAINING MATERIALS (ACMs) WILL BE ENCOUNTERED IN THE WORK. A REPORT ON THE PRESENCE OF ASBESTOS IS INCLUDED WITH THE CONTRACT DOCUMENTS FOR REVIEW AND USE BY THE CONTRACTOR. 17. THE CONTRACTOR IS RESPONSIBLE FOR COMPLYING WITH ALL THE CONTRACTOR IS RESPONSIBLE FOR COMPLYING WITH ALL NATIONAL, REGIONAL AND LOCAL CODES RELEVANT TO WORKING WITH HAZARDOUS MATERIALS INCLUDING BUT NOT LIMITED TO ASBESTOS AND LEAD BASED PAINT. 18. IF SUSPECT ACM MATERIAL IS FOUND AFTER THE PRIMARY IF SUSPECT ACM MATERIAL IS FOUND AFTER THE PRIMARY REMOVAL, THE CONTRACTOR SHALL STOP WORK IN THE SUBJECT AREA, TEST THE MATERIAL, CONFIRM THAT IT IS ACM, THEN NOTIFY THE GOVERNMENT. THE CONTRACTOR SHALL THEN ARRANGE FOR REMOVAL BY A PRE-APPROVED HAZMAT REMOVAL SUB-CONTRACTOR. 19. ALL DEMOLITION WORK SHALL BE EXECUTED IN CONFORMANCE ALL DEMOLITION WORK SHALL BE EXECUTED IN CONFORMANCE WITH ALL CODES AND REGULATIONS SET FORTH BY GOVERNING AUTHORITIES. 20. ALL ITEMS INDICATED TO BE REMOVED SHALL BE LEGALLY ALL ITEMS INDICATED TO BE REMOVED SHALL BE LEGALLY DISPOSED OF OFF-SITE. MATERIALS SHALL BE RECYCLED TO THE GREATEST EXTENT POSSIBLE. 21. ITEMS IDENTIFIED WITH DASHED LINES ON THE ARCHITECTURAL ITEMS IDENTIFIED WITH DASHED LINES ON THE ARCHITECTURAL DEMOLITION DRAWINGS ARE TO BE REMOVED UNLESS NOTED OTHERWISE. ADJACENT SURFACES AND REMAINING ITEMS ARE TO BE PRESERVED AND PROTECTED. 22. DEMOLITION SHALL NOT BE LIMITED TO ITEMS THUS SHOWN. DEMOLITION SHALL NOT BE LIMITED TO ITEMS THUS SHOWN. REQUIRED DEMOLITION INCLUDES REMOVAL OF ANY EXISTING CONSTRUCTION NEEDED TO ACCOMMODATE NEW CONSTRUCTION DESCRIBED IN THE CONTRACT DOCUMENTS. 23. MANUFACTURER'S WRITTEN RECOMMENDATIONS FOR INSTALLATION MANUFACTURER'S WRITTEN RECOMMENDATIONS FOR INSTALLATION ARE TO BE FOLLOWED FOR ALL ITEMS UNLESS SPECIFICALLY STATED OTHERWISE IN THE DRAWINGS OR SPECIFICATIONS. 24. GARDEN WILL BE CLOSED TO THE PUBLIC DURING CONSTRUCTION. GARDEN WILL BE CLOSED TO THE PUBLIC DURING CONSTRUCTION. PROVIDE OPEN ACCESS TO THE GARDEN FOR NPS EMPLOYEE MAINTENANCE. 25. HOT WORK PERMIT REQUIRED FOR ALL CONSTRUCTION ACTIVITIES HOT WORK PERMIT REQUIRED FOR ALL CONSTRUCTION ACTIVITIES THAT INVOLVE ANY BURNING, WELDING, BRAZING, GRINDING, ROOFING OR OPEN FLAME. PERMITS COORDINATED WITH COR AND ISSUED BY PARK STRUCTURAL FIRE COORDINATOR.

AutoCAD SHX Text

1. THESE NOTES ARE TO BE READ IN CONJUNCTION WITH ANY THESE NOTES ARE TO BE READ IN CONJUNCTION WITH ANY WRITTEN SPECIFICATIONS AND THESE DRAWINGS. IN THE EVENT OF CONFLICT BETWEEN THE INFORMATION ON THE DRAWINGS AND THE SPECIFICATIONS, THE MOST STRINGENT REQUIREMENTS SHALL GOVERN. 2. THIS IS A HISTORICALLY SIGNIFICANT BUILDING WHICH IS LISTED THIS IS A HISTORICALLY SIGNIFICANT BUILDING WHICH IS LISTED ON THE NATIONAL REGISTER OF HISTORIC PLACES, AND IS DESIGNATED AS A NATIONAL HISTORIC LANDMARK AND A NATIONAL MONUMENT. THE BUILDING SHALL BE TREATED RESPECTFULLY. EXISTING CONDITIONS ARE TO BE CAREFULLY RESPECTED AND NO MATERIAL OR BUILDING ELEMENT SHALL BE REMOVED OR DISFIGURED UNLESS SPECIFICALLY INDICATED ON THE DRAWINGS, SPECIFIED HEREIN, OR DIRECTED BY THE COR. 3. THIS BUILDING CONTAINS SENSITIVE HISTORIC SPACES, FEATURES, THIS BUILDING CONTAINS SENSITIVE HISTORIC SPACES, FEATURES, AND FINISHES THAT MUST BE PROTECTED AT ALL TIMES DURING CONSTRUCTION. REFER TO SPECIFICATION SECTION 013591, "HISTORIC TREATMENT PROCEDURES" FOR TEMPORARY PROTECTION REQUIREMENTS. 4. THE CONTRACTOR SHALL DOCUMENT EXISTING CONDITIONS PRIOR THE CONTRACTOR SHALL DOCUMENT EXISTING CONDITIONS PRIOR TO BEGINNING THE WORK. THE CONTRACTOR SHALL PROVIDE PROTECTION AND TAKE PRECAUTION TO AVOID DAMAGE TO ADJACENT ITEMS, MATERIALS AND FINISHES. DEMOLITION AND NEW CONSTRUCTION SHALL PROCEED WITH CARE SO AS TO NOT DAMAGE HISTORIC FINISHES. ANY EXISTING ITEMS OR FINISHES DAMAGED BY THE CONTRACTOR SHALL BE RESTORED TO THEIR ORIGINAL CONDITION OR BETTER UNLESS AT NO ADDITIONAL COST TO THE GOVERNMENT. 5. CONTRACTOR SHALL USE ALL REASONABLE AND CUSTOMARY CARE CONTRACTOR SHALL USE ALL REASONABLE AND CUSTOMARY CARE TO VERIFY ALL EXISTING CONDITIONS IN FIELD. CONTRACTOR SHALL NOTIFY COR IMMEDIATELY OF INCONSISTENCIES BETWEEN THESE DRAWINGS AND ACTUAL CONDITIONS BEFORE PROCEEDING WITH CONSTRUCTION OR DEMOLITION. INFORMATION CONTAINED ON THESE DRAWINGS WITH REGARD TO EXISTING CONDITIONS OF CONSTRUCTION IS PROVIDED FOR THE CONVENIENCE OF THE CONTRACTOR IN EXECUTING THE WORK. THESE DRAWINGS HAVE BEEN BASED ON DRAWINGS FROM THE HISTORIC STRUCTURE REPORT AND FURTHER SUPPLEMENTED BY FIELD MEASUREMENT AND OBSERVATIONS. 6. THE FOLLOWING WORDS AND PHRASES ARE DEFINED AS FOLLOWS: THE FOLLOWING WORDS AND PHRASES ARE DEFINED AS FOLLOWS: 6.1. EXISTING TO REMAIN: LEAVE EXISTING ITEMS THAT ARE NOT EXISTING TO REMAIN: LEAVE EXISTING ITEMS THAT ARE NOT TO BE REMOVED, AND THAT ARE NOT OTHERWISE INDICATED TO BE SALVAGED OR REINSTALLED. 6.2. REMOVE: DETACH ITEMS FROM EXISTING CONSTRUCTION AND REMOVE: DETACH ITEMS FROM EXISTING CONSTRUCTION AND DISPOSE OF THEM OFF-SITE UNLESS INDICATED TO BE SALVAGED OR REINSTALLED. 6.3. REMOVE AND SALVAGE: DETACH ITEMS FROM EXISTING REMOVE AND SALVAGE: DETACH ITEMS FROM EXISTING CONSTRUCTION, IN A MANNER TO PREVENT DAMAGE, AND DELIVER TO OWNER READY FOR REUSE. 6.4. REPLACE: TO REMOVE, DUPLICATE, AND REINSTALL ENTIRE REPLACE: TO REMOVE, DUPLICATE, AND REINSTALL ENTIRE ITEM WITH NEW MATERIAL. THE ORIGINAL ITEM IS THE PATTERN FOR CREATING DUPLICATES UNLESS OTHERWISE INDICATED. 6.5. REINSTALL: TO PROTECT REMOVED OR DISMANTLED ITEM, REINSTALL: TO PROTECT REMOVED OR DISMANTLED ITEM, REPAIR AND CLEAN IT AS INDICATED FOR REUSE, AND REINSTALL IT IN ORIGINAL POSITION, OR WHERE INDICATED. 6.6. PROVIDE: FURNISH AND INSTALL NEW ITEM. PROVIDE: FURNISH AND INSTALL NEW ITEM. 6.7. COMPLETE/LY: 100% OF THE IDENTIFIED SURFACE PLANE: COMPLETE/LY: 100% OF THE IDENTIFIED SURFACE PLANE: WALL TO WALL OR CORNER TO CORNER. 6.8. PAINT: PREPARE SURFACE AS SPECIFIED (IE. REMOVE PAINT: PREPARE SURFACE AS SPECIFIED (IE. REMOVE MISCELLANEOUS HARDWARE, PATCH MINOR HOLES AND CRACKS, SEAL STAINS, ETC.) AND PAINT. 6.9. REPAIR: TO CORRECT DAMAGE AND DEFECTS, RETAINING REPAIR: TO CORRECT DAMAGE AND DEFECTS, RETAINING EXISTING MATERIALS, FEATURES, AND FINISHES WHILE EMPLOYING AS LITTLE NEW MATERIAL AS POSSIBLE. THIS INCLUDES PATCHING, PIECING-IN, SPLICING, CONSOLIDATING, OR OTHERWISE REINFORCING OR UPGRADING MATERIALS. 6.10. TYPICAL: THE IDENTIFIED TREATMENT IS TO BE APPLIED AT TYPICAL: THE IDENTIFIED TREATMENT IS TO BE APPLIED AT ADDITIONAL LOCATIONS THROUGHOUT THE DRAWING WHERE SIMILAR CONDITIONS EXIST. 6.11. SIMILAR: THE REFERENCED DETAIL MUST BE MODIFIED TO SIMILAR: THE REFERENCED DETAIL MUST BE MODIFIED TO MEET THE REQUIREMENTS OF THIS SPECIFIC LOCATION. CONTRACTOR IS TO SUBMIT MARKED DETAIL SKETCH FOR REVIEW BY THE COR. 6.12. COR: THE GOVERNMENT CONTRACTING OFFICER OR A COR: THE GOVERNMENT CONTRACTING OFFICER OR A REPRESENTATIVE DESIGNATED BY THE CONTRACTING OFFICER. 7. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR SEQUENCING ALL THE CONTRACTOR IS SOLELY RESPONSIBLE FOR SEQUENCING ALL WORK AND FOR COORDINATION OF ALL SUBCONTRACTORS. REINSTALLATION OF ANY WORK INSTALLED THAT HAS NOT BEEN COORDINATED AND HAS TO BE REINSTALLED SHALL BE DONE AT THE CONTRACTOR'S EXPENSE. 8. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE WORK THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE WORK OF ALL TRADES TO ASSURE PROPER REMOVAL OF EXISTING CONSTRUCTION AND THE INSTALLATION OF ALL NEW CONSTRUCTION. 9. PARKING AREAS, DRIVEWAYS, SIDEWALKS, AND SURFACED STREETS PARKING AREAS, DRIVEWAYS, SIDEWALKS, AND SURFACED STREETS SHALL BE MAINTAINED IN A CLEAN CONDITION, ADEQUATE MEANS SHALL BE PROVIDED TO CLEAN TRUCKS AND OTHER EQUIPMENT USING SURFACED STREETS AND PARKING AREAS. 10. THE CONTRACTOR'S EQUIPMENT AND STAGING SHALL NOT BLOCK THE CONTRACTOR'S EQUIPMENT AND STAGING SHALL NOT BLOCK BUILDING EXITS NOR LIMIT ACCESS TO THE STRUCTURE BY THE FIRE DEPARTMENT IN THE EVENT OF AN EMERGENCY. 11. PARKING OF CONTRACTOR VEHICLES AND MATERIALS DELIVERIES PARKING OF CONTRACTOR VEHICLES AND MATERIALS DELIVERIES AREA STRICTLY LIMITED TO 4 CURB PERMITTED PARKING SPACES ON SECOND STREET NE. 12. THE EXISTING BUILDING ENVELOPE SHALL BE MAINTAINED IN A THE EXISTING BUILDING ENVELOPE SHALL BE MAINTAINED IN A WATERTIGHT CONDITION AT ALL TIMES DURING CONSTRUCTION. 13. ALL DIMENSIONS TO NEW CONSTRUCTION ARE TO FACE OF ALL DIMENSIONS TO NEW CONSTRUCTION ARE TO FACE OF STRUCTURE. ALL DIMENSIONS TO EXISTING CONSTRUCTION ARE TO FINISH FACE UNLESS OTHERWISE NOTED. NOTES TO ALIGN NEW CONSTRUCTION WITH EXISTING CONDITIONS ARE FROM FACE OF EXISTING FINISH TO FACE OF NEW FINISH. 14. THESE DRAWINGS ARE NOT TO BE SCALED FOR THE PURPOSE OF THESE DRAWINGS ARE NOT TO BE SCALED FOR THE PURPOSE OF LAYING OUT DEMOLITION OR NEW WORK. USE FIGURED DIMENSIONS ONLY. 15. LEAD PAINT WILL BE ENCOUNTERED IN THE WORK, A REPORT ON LEAD PAINT WILL BE ENCOUNTERED IN THE WORK, A REPORT ON THE PRESENCE OF LEAD PAINT IS INCLUDED WITH THE CONTRACT DOCUMENTS FOR REVIEW AND USE BY THE CONTRACTOR. 16. ASBESTOS CONTAINING MATERIALS (ACMs) WILL BE ENCOUNTERED ASBESTOS CONTAINING MATERIALS (ACMs) WILL BE ENCOUNTERED IN THE WORK. A REPORT ON THE PRESENCE OF ASBESTOS IS INCLUDED WITH THE CONTRACT DOCUMENTS FOR REVIEW AND USE BY THE CONTRACTOR. 17. THE CONTRACTOR IS RESPONSIBLE FOR COMPLYING WITH ALL THE CONTRACTOR IS RESPONSIBLE FOR COMPLYING WITH ALL NATIONAL, REGIONAL AND LOCAL CODES RELEVANT TO WORKING WITH HAZARDOUS MATERIALS INCLUDING BUT NOT LIMITED TO ASBESTOS AND LEAD BASED PAINT. 18. IF SUSPECT ACM MATERIAL IS FOUND AFTER THE PRIMARY IF SUSPECT ACM MATERIAL IS FOUND AFTER THE PRIMARY REMOVAL, THE CONTRACTOR SHALL STOP WORK IN THE SUBJECT AREA, TEST THE MATERIAL, CONFIRM THAT IT IS ACM, THEN NOTIFY THE GOVERNMENT. THE CONTRACTOR SHALL THEN ARRANGE FOR REMOVAL BY A PRE-APPROVED HAZMAT REMOVAL SUB-CONTRACTOR. 19. ALL DEMOLITION WORK SHALL BE EXECUTED IN CONFORMANCE ALL DEMOLITION WORK SHALL BE EXECUTED IN CONFORMANCE WITH ALL CODES AND REGULATIONS SET FORTH BY GOVERNING AUTHORITIES. 20. ALL ITEMS INDICATED TO BE REMOVED SHALL BE LEGALLY ALL ITEMS INDICATED TO BE REMOVED SHALL BE LEGALLY DISPOSED OF OFF-SITE. MATERIALS SHALL BE RECYCLED TO THE GREATEST EXTENT POSSIBLE. 21. ITEMS IDENTIFIED WITH DASHED LINES ON THE ARCHITECTURAL ITEMS IDENTIFIED WITH DASHED LINES ON THE ARCHITECTURAL DEMOLITION DRAWINGS ARE TO BE REMOVED UNLESS NOTED OTHERWISE. ADJACENT SURFACES AND REMAINING ITEMS ARE TO BE PRESERVED AND PROTECTED. 22. DEMOLITION SHALL NOT BE LIMITED TO ITEMS THUS SHOWN. DEMOLITION SHALL NOT BE LIMITED TO ITEMS THUS SHOWN. REQUIRED DEMOLITION INCLUDES REMOVAL OF ANY EXISTING CONSTRUCTION NEEDED TO ACCOMMODATE NEW CONSTRUCTION DESCRIBED IN THE CONTRACT DOCUMENTS. 23. MANUFACTURER'S WRITTEN RECOMMENDATIONS FOR INSTALLATION MANUFACTURER'S WRITTEN RECOMMENDATIONS FOR INSTALLATION ARE TO BE FOLLOWED FOR ALL ITEMS UNLESS SPECIFICALLY STATED OTHERWISE IN THE DRAWINGS OR SPECIFICATIONS. 24. GARDEN WILL BE CLOSED TO THE PUBLIC DURING CONSTRUCTION. GARDEN WILL BE CLOSED TO THE PUBLIC DURING CONSTRUCTION. PROVIDE OPEN ACCESS TO THE GARDEN FOR NPS EMPLOYEE MAINTENANCE. 25. HOT WORK PERMIT REQUIRED FOR ALL CONSTRUCTION ACTIVITIES HOT WORK PERMIT REQUIRED FOR ALL CONSTRUCTION ACTIVITIES THAT INVOLVE ANY BURNING, WELDING, BRAZING, GRINDING, ROOFING OR OPEN FLAME. PERMITS COORDINATED WITH COR AND ISSUED BY PARK STRUCTURAL FIRE COORDINATOR.

AutoCAD SHX Text

ABBREVIATIONS

AutoCAD SHX Text ALT ALTERNATE ALTERNATE APPROX APPROXIMATELY APPROXIMATELY DWG DRAWINGS DRAWINGS CLG CEILING CEILING COR CONTRACTING OFFICER CONTRACTING OFFICER EXIST EXISTING EXISTING ELEC ELECTRICAL ELECTRICAL ELEV ELEVATION ELEVATION EXSC EXISTING SCONCE EXISTING SCONCE EXSD EXISTING SMOKE DETECTOR EXISTING SMOKE DETECTOR FCU FAN COIL UNIT FAN COIL UNIT FLR FLOOR FLOOR LF LINEAR FEET LINEAR FEET LOC LOCATION(S) LOCATION(S) MECH MECHANICAL MECHANICAL PLUMB PLUMBING PLUMBING PLAS PLASTER PLASTER PT PAINT PAINT RCP REFLECTED CEILING PLAN REFLECTED CEILING PLAN SO SOUTH SOUTH ST STONE STONE SF/SQFT SQUARE FEET SQUARE FEET VERT VERTICAL VERTICAL WD WOODWOOD

AutoCAD SHX Text

GENERAL HAZARDOUS MATERIALS NOTES

AutoCAD SHX Text

1. WHILE ASBESTOS-CONTAINING MATERIALS (ACMS) HAVE BEEN WHILE ASBESTOS-CONTAINING MATERIALS (ACMS) HAVE BEEN IDENTIFIED WITHIN THE PROJECT AREA, NO ABATEMENT OF ACMS WILL BE PERFORMED AT THIS TIME. COORDINATE WITH OTHER TRADES AS REQUIRED TO ENSURE WORKER SAFETY AND PROPER MONITORING OF ACMS. 2. LEAD-BASED PAINT (LBP) AND LEAD-CONTAINING PAINT (LCP) LEAD-BASED PAINT (LBP) AND LEAD-CONTAINING PAINT (LCP) HAS BEEN IDENTIFIED WITHIN THE PROJECT AREA. COORDINATE LEAD MANAGEMENT WITH OTHER TRADES AS REQUIRED TO ENSURE WORKER SAFETY. LEAD SAFE WORK PRACTICES SHALL BE EMPLOYED PER THE OSHA LEAD IN CONSTRUCTION STANDARD (29 CFR 1626.62). 3. CONTRACTOR IS RESPONSIBLE FOR THE COLLECTION AND CONTRACTOR IS RESPONSIBLE FOR THE COLLECTION AND ANALYSIS OF TCLP SAMPLE FOR CHARACTERIZATION AND PROPER DISPOSAL OF GENERATED WASTES. 4. THE CONSTRUCTION CONTRACTOR SHALL MONITOR THE AREA AND THE CONSTRUCTION CONTRACTOR SHALL MONITOR THE AREA AND ALL AFFECTED PERSONNEL DURING CONSTRUCTION. 5. GATHER, COLLECT, AND PROPERLY DISPOSE OF ALL GATHER, COLLECT, AND PROPERLY DISPOSE OF ALL MERCURY-CONTAINING LIGHT TUBES AND IDENTIFIED LIGHT BALLASTS ROM REMOVED LIGHT FIXTURES. 6. CONTRACTOR IS RESPONSIBLE FOR ALL HAZARDOUS WASTE CONTRACTOR IS RESPONSIBLE FOR ALL HAZARDOUS WASTE GENERATED. WHEN WASTE IS GENERATED ON THE NPS' PREMISES, THE NPS SHALL APPOINT A REPRESENTATIVE TO REVIEW ALL PAPERWORK (I.E., MANIFESTS AND WASTE PROFILES). THE HAZARDOUS WASTE DISPOSAL SITE MUST BE SUBMITTED AND PRE-APPROVED BY THE NPS' REPRESENTATIVE.

AutoCAD SHX Text

ITEM TO BE DEMOLISHED

AutoCAD SHX Text

SHEET WHERE DETAIL CAME FROM

AutoCAD SHX Text

SHEET WHERE DETAIL IS LOCATED

AutoCAD SHX Text

SHEET WHERE DETAIL CAME FROM

AutoCAD SHX Text

DIMENSION

AutoCAD SHX Text

NEW DOOR

AutoCAD SHX Text

DETAIL NUMBER REFERENCE

AutoCAD SHX Text

SHEET WHERE DETAIL IS LOCATED

AutoCAD SHX Text

BLDG. SECTION NUMBER REFERENCE

AutoCAD SHX Text

DETAIL REFERENCE

AutoCAD SHX Text

SECTION CUTS

AutoCAD SHX Text

/EXTERIOR ELEVATIONS

AutoCAD SHX Text X

AutoCAD SHX Text

AXXX

AutoCAD SHX Text

AXXX

AutoCAD SHX Text X

AutoCAD SHX Text

AXXX

AutoCAD SHX Text

AXXX

AutoCAD SHX Text

DRAWING SYMBOLS

AutoCAD SHX Text

144 CONSTITUTION AVE, NE WASHINGTON, DC

AutoCAD SHX Text

REHABILITATE BELMONT-PAUL MONUMENT

AutoCAD SHX Text

NATIONAL MALL AND MEMORIAL PARKS (NAMA)

AutoCAD SHX Text 11/30/20

AutoCAD SHX Text

NATIONAL PARK SERVICE - NATIONAL CAPITAL REGION

AutoCAD SHX Text

DESIGN AND PROJECT MANAGEMENT

AutoCAD SHX Text

UNITED STATES

AutoCAD SHX Text

OF

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DWG. NO.

AutoCAD SHX Text

DATE

AutoCAD SHX Text

DEPARTMENT OF THE INTERIOR

AutoCAD SHX Text

SUB SHEET NUMBER

AutoCAD SHX Text

TITLE OF DRAWING

AutoCAD SHX Text Mark

AutoCAD SHX Text Sheet

AutoCAD SHX Text Initial

AutoCAD SHX Text Date

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DESIGNED

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

CHECKED

AutoCAD SHX Text

TITLE OF PROJECT

AutoCAD SHX Text

NAME OF PARK

AutoCAD SHX Text

LOCATION WITHIN PARK

AutoCAD SHX Text

BEPA ROOF CD PHASE II

AutoCAD SHX Text

RJ

AutoCAD SHX Text

RJ

AutoCAD SHX Text

CD

AutoCAD SHX Text PMIS No.

AutoCAD SHX Text 310286

AutoCAD SHX Text

AutoCAD SHX Text

GENERAL NOTES, ABBREVIATIONS, AND SYMBOLS

AutoCAD SHX Text A001

UP

UP

UP

UP

DN

UP

UP

UP

UP

SHEET NOTES

1. GUTTERS AND DOWNSPOUTS NOT SHOWN. SEE

RELATED SCOPE ON SHEETS A-200 TO A-205.

2. CONTRACTOR TO VERIFY ALL DIMS IN FIELD.

3. ALL WORK FROM ROOF TERRACE SHALL BE

ACCESSED FROM THE EXTERIOR.

EXISTING

STAIRS AND

LANDINGS

ACCESSIBLE LIFT

PROPOSED

CONSTRUCTION

MATERIALS

STORAGE AREA.

BOUNDARY WALL

EXISTING SHED

NORTH TERRACE

AutoCAD SHX Text

144 CONSTITUTION AVE, NE WASHINGTON, DC

AutoCAD SHX Text

REHABILITATE BELMONT-PAUL MONUMENT

AutoCAD SHX Text

NATIONAL MALL AND MEMORIAL PARKS (NAMA)

AutoCAD SHX Text 11/30/20

AutoCAD SHX Text

NATIONAL PARK SERVICE - NATIONAL CAPITAL REGION

AutoCAD SHX Text

DESIGN AND PROJECT MANAGEMENT

AutoCAD SHX Text

UNITED STATES

AutoCAD SHX Text

OF

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DWG. NO.

AutoCAD SHX Text

DATE

AutoCAD SHX Text

DEPARTMENT OF THE INTERIOR

AutoCAD SHX Text

SUB SHEET NUMBER

AutoCAD SHX Text

TITLE OF DRAWING

AutoCAD SHX Text Mark

AutoCAD SHX Text Sheet

AutoCAD SHX Text Initial

AutoCAD SHX Text Date

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DESIGNED

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

CHECKED

AutoCAD SHX Text

TITLE OF PROJECT

AutoCAD SHX Text

NAME OF PARK

AutoCAD SHX Text

LOCATION WITHIN PARK

AutoCAD SHX Text

BEPA ROOF CD PHASE II

AutoCAD SHX Text

RJ

AutoCAD SHX Text

RJ

AutoCAD SHX Text

CD

AutoCAD SHX Text PMIS No.

AutoCAD SHX Text 310286

AutoCAD SHX Text

AutoCAD SHX Text

CONSTITUTION AVENUE NE

AutoCAD SHX Text

2ND STREET NE

AutoCAD SHX Text

SOUTH EXTERIOR TERRACE

AutoCAD SHX Text

ROOF TERRACE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A100

AutoCAD SHX Text

SITE PLAN

AutoCAD SHX Text

SCALE A

AutoCAD SHX Text

SCALE OF FEET

AutoCAD SHX Text A002

AutoCAD SHX Text

AutoCAD SHX Text

STAGING AND ACCESS PLAN

AutoCAD SHX Text

SCALE A

AutoCAD SHX Text

HEDGE

AutoCAD SHX Text

CONTRACTOR ACCESS

AutoCAD SHX Text

VISITOR ACCESSIBLE ACCESS TO ENTRANCE

AutoCAD SHX Text

VISITOR MAIN ENTRANCE

AutoCAD SHX Text

EXISTING AWNING ABOVE

41'-0 5/8"30'-9 5/16"

DN

REMOVE EXISTING STANDING SEAM METAL ROOF AND

RIDGES DOWN TO SUBSTRATE. PROVIDE ALLOWANCE

TO REMOVE 30% OF DAMAGED SUBSTRATE AND

RAFTERS. SALVAGE ALL SNOW GUARDS

REMOVE EXISTING STANDING SEAM METAL

ROOF DOWN TO SUBSTRATE. SALVAGE SNOW

GUARDS FOR REINSTALLATION. PROVIDE

ALLOWANCE TO REMOVE 30% OF DAMAGED

SUBSTRATE AND RAFTERS. REMOVE EXISTING

METAL ROOF RIDGE. SALVAGE SNOW GUARDS

FOR REINSTALLATION.

EXISTING ROOF TERRACE

INCLUDING RUBBER ROOF

PAVERS AND WOOD

RAILINGS TO REMAIN.

REMOVE EXISTING

ROOF VENTS AND

REPLACE WITH NEW.

REMOVE EXISTING

ROOF VENTS AND

REPLACE WITH NEW.

EXISTING SLATE

ROOF ON SOUTH

ELEVATION TO

REMAIN.

EXISTING SLATE

ROOFS ON DORMERS

TO REMAIN. (TYP.)

REMOVE EXISTING

STANDING SEAM

METAL ROOF DOWN

TO SUBSTRATE.

PROVIDE ALLOWANCE

TO REMOVE 30% OF

DAMAGED SUBSTRATE

AND RAFTERS.

SALVAGE SNOW

GUARDS FOR

REINSTALLATION.

EXISTING CHIMNEY TO

REMAIN. REPLACE

ANY DAMAGED

FLASHING RESULTING

FROM DEMOLITION OF

STANDING SEAM

METAL ROOF.

REMOVE EXISTING STANDING

SEAM METAL ROOF DOWN TO

SUBSTRATE. SALVAGE SNOW

GUARDS FOR REINSTALLATION.

PROVIDE ALLOWANCE TO

REMOVE 30% OF DAMAGED

SUBSTRATE AND RAFTERS.

REMOVE EXISTING METAL

ROOF RIDGE. SALVAGE SNOW

GUARDS FOR INSTALLATION.

EXISTING CHIMNEY TO

REMAIN. REPLACE ANY

DAMAGED FLASHING

RESULTING FROM

DEMOLITION OF STANDING

SEAM METAL ROOF.

EXISTING CHIMNEY TO REMAIN. REPLACE ANY

DAMAGED FLASHING RESULTING FROM

DEMOLITION OF STANDING SEAM METAL ROOF.

REMOVE AND

REPAIR WOOD TRIM

AS REQUIRED TO

ACCOMODATE NEW

METAL ROOF AND

FLASHING ABOVE

DORMER WINDOWS.

(TYP.)

REMOVE EXISTING

ROOF HATCH AND

REPLACE WITH NEW.

AutoCAD SHX Text

144 CONSTITUTION AVE, NE WASHINGTON, DC

AutoCAD SHX Text

REHABILITATE BELMONT-PAUL MONUMENT

AutoCAD SHX Text

NATIONAL MALL AND MEMORIAL PARKS (NAMA)

AutoCAD SHX Text 11/30/20

AutoCAD SHX Text

NATIONAL PARK SERVICE - NATIONAL CAPITAL REGION

AutoCAD SHX Text

DESIGN AND PROJECT MANAGEMENT

AutoCAD SHX Text

UNITED STATES

AutoCAD SHX Text

OF

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DWG. NO.

AutoCAD SHX Text

DATE

AutoCAD SHX Text

DEPARTMENT OF THE INTERIOR

AutoCAD SHX Text

SUB SHEET NUMBER

AutoCAD SHX Text

TITLE OF DRAWING

AutoCAD SHX Text Mark

AutoCAD SHX Text Sheet

AutoCAD SHX Text Initial

AutoCAD SHX Text Date

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DESIGNED

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

CHECKED

AutoCAD SHX Text

TITLE OF PROJECT

AutoCAD SHX Text

NAME OF PARK

AutoCAD SHX Text

LOCATION WITHIN PARK

AutoCAD SHX Text

BEPA ROOF CD PHASE II

AutoCAD SHX Text

RJ

AutoCAD SHX Text

RJ

AutoCAD SHX Text

CD

AutoCAD SHX Text PMIS No. 310286

AutoCAD SHX Text

AutoCAD SHX Text

AD101

AutoCAD SHX Text

AutoCAD SHX Text

ROOF PLAN - SOUTH END

AutoCAD SHX Text

MATCHLINE SEE 1/AD102

AutoCAD SHX Text

AD101

AutoCAD SHX Text

AutoCAD SHX Text

SOUTH ELEVATION

AutoCAD SHX Text

NO SCALE

AutoCAD SHX Text

AD101

AutoCAD SHX Text

DEMO ROOF PLAN - SOUTH END

AutoCAD SHX Text

SCALE A

AutoCAD SHX Text

SCALE A

AutoCAD SHX Text

SCALE OF FEET

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AD101

AutoCAD SHX Text

AutoCAD SHX Text

MATCH LINE

AutoCAD SHX Text

AD102

58'-4 7/16"

SHEET NOTES

1. GUTTERS AND DOWNSPOUTS NOT SHOWN. SEE

RELATED SCOPE ON SHEETS A-200 TO A-205.

2. CONTRACTOR TO VERIFY ALL DIMS IN FIELD.

3. ALL WORK FROM ROOF TERRACE SHALL BE

ACCESSED FROM THE EXTERIOR.

REMOVE EXISTING STANDING SEAM METAL ROOF

AND RIDGES DOWN TO SUBSTRATE. PROVIDE

ALLOWANCE TO REMOVE 30% OF DAMAGED

SUBSTRATE AND RAFTERS. SALVAGE SNOW

GUARDS FOR REINSTALLATION.

EXISTING CHIMNEY TO REMAIN. REPLACE ANY

DAMAGED FLASHING RESULTING FROM

DEMOLITION OF STANDING SEAM METAL ROOF.

EXISTING ROOF TERRACE

INCLUDING RUBBER ROOF

PAVERS AND WOOD RAILINGS

TO REMAIN.

REMOVE AND

REPAIR WOOD TRIM

AS REQUIRED TO

ACCOMODATE NEW

ROOF ABOVE

WINDOW DORMERS.

(TYP.)

AutoCAD SHX Text

144 CONSTITUTION AVE, NE WASHINGTON, DC

AutoCAD SHX Text

REHABILITATE BELMONT-PAUL MONUMENT

AutoCAD SHX Text

NATIONAL MALL AND MEMORIAL PARKS (NAMA)

AutoCAD SHX Text 11/30/20

AutoCAD SHX Text

NATIONAL PARK SERVICE - NATIONAL CAPITAL REGION

AutoCAD SHX Text

DESIGN AND PROJECT MANAGEMENT

AutoCAD SHX Text

UNITED STATES

AutoCAD SHX Text

OF

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DATE

AutoCAD SHX Text

DEPARTMENT OF THE INTERIOR

AutoCAD SHX Text

SUB SHEET NUMBER

AutoCAD SHX Text

TITLE OF DRAWING

AutoCAD SHX Text Mark

AutoCAD SHX Text Sheet

AutoCAD SHX Text Initial

AutoCAD SHX Text Date

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DESIGNED

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

CHECKED

AutoCAD SHX Text

TITLE OF PROJECT

AutoCAD SHX Text

NAME OF PARK

AutoCAD SHX Text

LOCATION WITHIN PARK

AutoCAD SHX Text

BEPA ROOF CD PHASE II

AutoCAD SHX Text

RJ

AutoCAD SHX Text

RJ

AutoCAD SHX Text

CD

AutoCAD SHX Text PMIS No.

AutoCAD SHX Text 310286

AutoCAD SHX Text

AutoCAD SHX Text

MATCHLINE SEE 1/AD101

AutoCAD SHX Text

MATCH LINE

AutoCAD SHX Text

AD102

AutoCAD SHX Text

DEMO ROOF PLAN - NORTH END

AutoCAD SHX Text

SCALE A

AutoCAD SHX Text

AD102

AutoCAD SHX Text

AutoCAD SHX Text

DEMO ROOF PLAN - NORTH END

AutoCAD SHX Text

SCALE A

AutoCAD SHX Text

SCALE OF FEET

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AD102

AutoCAD SHX Text

AutoCAD SHX Text

ROOF DORMER

NOT TO SCALE

T

Y P

T

Y P

58'-4 7/16"

SHEET NOTES

1. GUTTERS AND DOWNSPOUTS NOT SHOWN. SEE

RELATED SCOPE ON SHEETS A-200 TO A-205.

2. CONTRACTOR TO VERIFY ALL DIMS IN FIELD.

3. ALL WORK FROM ROOF TERRACE SHALL BE

ACCESSED FROM THE EXTERIOR.

4. PAINT NEW STANDING SEAM TIN/ZINC COATED

COPPER ROOF TO MATCH EXISTING.

INSTALL NEW STANDING SEAM TIN/ZINC COATED

COPPER ROOF AND SUBSTRATE AS NECESSARY TO

MATCH EXISTING CONFIGURATION AND IN

ACCORDANCE WITH SMACNA GUIDELINES. PAINT

TO MATCH EXISTING. (TYP.)

REINSTALL TWO ROWS

OF EXISTING SNOW

GUARDS WHERE SHOWN.

REPAIR ANY DAMAGED

STEPPED FLASHING AT

BASE OF CHIMNEY

RESULTING FROM

DEMOLITION OF STANDING

SEAM METAL ROOF.

INSTALL NEW

STANDING SEAM

TIN/ZINC COATED

COPPER ROOF RIDGE

IN ACCORDANCE WITH

SMACNA GUIDELINES.

PAINT TO MATCH

EXISTING.

REINSTALL TWO

ROWS OF EXISTING

SNOW GUARDS

WHERE SHOWN.

EXISTING ROOF TERRACE

INCLUDING RUBBER ROOF PAVERS

AND WOOD RAILINGS TO REMAIN.

AutoCAD SHX Text

144 CONSTITUTION AVE, NE WASHINGTON, DC

AutoCAD SHX Text

REHABILITATE BELMONT-PAUL MONUMENT

AutoCAD SHX Text

NATIONAL MALL AND MEMORIAL PARKS (NAMA)

AutoCAD SHX Text 11/30/20

AutoCAD SHX Text

NATIONAL PARK SERVICE - NATIONAL CAPITAL REGION

AutoCAD SHX Text

DESIGN AND PROJECT MANAGEMENT

AutoCAD SHX Text

UNITED STATES

AutoCAD SHX Text

OF

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DWG. NO.

AutoCAD SHX Text

DATE

AutoCAD SHX Text

DEPARTMENT OF THE INTERIOR

AutoCAD SHX Text

SUB SHEET NUMBER

AutoCAD SHX Text

TITLE OF DRAWING

AutoCAD SHX Text Mark

AutoCAD SHX Text Sheet

AutoCAD SHX Text Initial

AutoCAD SHX Text Date

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DESIGNED

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

CHECKED

AutoCAD SHX Text

TITLE OF PROJECT

AutoCAD SHX Text

NAME OF PARK

AutoCAD SHX Text

LOCATION WITHIN PARK

AutoCAD SHX Text

BEPA ROOF CD PHASE II

AutoCAD SHX Text

RJ

AutoCAD SHX Text

RJ

AutoCAD SHX Text

CD

AutoCAD SHX Text PMIS No.

AutoCAD SHX Text 310286

AutoCAD SHX Text

AutoCAD SHX Text

MATCHLINE SEE 1/A104

AutoCAD SHX Text

MATCH LINE

AutoCAD SHX Text A102

AutoCAD SHX Text

NEW ROOF PLAN - NORTH END

AutoCAD SHX Text

SCALE A

AutoCAD SHX Text A105

AutoCAD SHX Text

AutoCAD SHX Text

ROOF PLAN - NORTH END

AutoCAD SHX Text

SCALE A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SCALE OF FEET

AutoCAD SHX Text

2% SLOPE

EDGE OF ROOF

ROOF PEAK

PAVEMENT

TOP OF CHIMNEY

THRESHOLD

SHEET NOTES

1. REFERENCE ROOF PLAN FOR ADDITIONAL WORK

NOT SHOWN ON ELEVATIONS.

2. PAINT NEW STANDING SEAM TIN/ZINC COATED

COPPER ROOF.

3. REPLACE ALL GUTTERS AND DOWNSPOUTS TO

MATCH EXISTING.

4. CONTRACTOR TO VERIFY ALL DIMS IN FIELD.

INSTALL NEW STANDING SEAM TIN/ZINC

COATED COPPER ROOF AND

SUBSTRATE AS NECESSARY TO MATCH

EXISTING CONFIGURATION AND IN

ACCORDANCE WITH SMACNA

GUIDELINES. PAINT TO MATCH

EXISTING. (TYP.)

REMOVE AND REPAIR WOOD

TRIM AS REQUIRED TO

ACCOMODATE NEW ROOF.

MATCH EXISTING PROFILE.

(TYP.)

WHERE MISSING, PROVIDE

RECTANGULAR SLATE

SHINGLES TO MATCH

EXISTING IN COLOR,

SHAPE, AND TEXTURE.

INSTALL NEW FLASHING

AND DRIP EDGE ABOVE

WINDOW DORMERS IN

ACCORDANCE WITH

SMACNA GUIDELINES.

(TYP.)

REPLACE ALL GUTTERS

AND DOWNSOUTS TO

MATCH EXISTING. (TYP)

AutoCAD SHX Text

144 CONSTITUTION AVE, NE WASHINGTON, DC

AutoCAD SHX Text

REHABILITATE BELMONT-PAUL MONUMENT

AutoCAD SHX Text

NATIONAL MALL AND MEMORIAL PARKS (NAMA)

AutoCAD SHX Text 11/30/20

AutoCAD SHX Text

NATIONAL PARK SERVICE - NATIONAL CAPITAL REGION

AutoCAD SHX Text

DESIGN AND PROJECT MANAGEMENT

AutoCAD SHX Text

UNITED STATES

AutoCAD SHX Text

OF

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DWG. NO.

AutoCAD SHX Text

DATE

AutoCAD SHX Text

DEPARTMENT OF THE INTERIOR

AutoCAD SHX Text

SUB SHEET NUMBER

AutoCAD SHX Text

TITLE OF DRAWING

AutoCAD SHX Text Mark

AutoCAD SHX Text Sheet

AutoCAD SHX Text Initial

AutoCAD SHX Text Date

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DESIGNED

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

CHECKED

AutoCAD SHX Text

TITLE OF PROJECT

AutoCAD SHX Text

NAME OF PARK

AutoCAD SHX Text

LOCATION WITHIN PARK

AutoCAD SHX Text

BEPA ROOF CD PHASE II

AutoCAD SHX Text

RJ

AutoCAD SHX Text

RJ

AutoCAD SHX Text

CD

AutoCAD SHX Text 310286

AutoCAD SHX Text

AutoCAD SHX Text PMIS No.

AutoCAD SHX Text

AD102

AutoCAD SHX Text

AutoCAD SHX Text A200

AutoCAD SHX Text

SOUTH ELEVATION

AutoCAD SHX Text

SCALE A

AutoCAD SHX Text A200

AutoCAD SHX Text

AutoCAD SHX Text

SOUTH ELEVATION

AutoCAD SHX Text

SCALE A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SCALE OF FEET

EDGE OF ROOF

ROOF PEAK

GRADE

TOP OF

CHIMNEY

THRESHOLD

SHEET NOTES

1. REFERENCE ROOF PLAN FOR ADDITIONAL WORK

NOT SHOWN ON ELEVATIONS.

2. PAINT NEW STANDING SEAM TIN/ZINC COATED

COPPER ROOF.

3. REPLACE ALL GUTTERS AND DOWNSPOUTS TO

MATCH EXISTING.

4. CONTRACTOR TO VERIFY ALL DIMS IN FIELD.

WHERE MISSING, PROVIDE

RECTANGULAR SLATE SHINGLES TO

MATCH EXISTING IN COLOR, SHAPE,

AND TEXTURE.

INSTALL

NEW

STANDING

SEAM

TIN/ZINC

COATED

COPPER ON

DORMER

ELEVATION.

INSTALL NEW STANDING SEAM

TIN/ZINC COATED COPPER ROOF AND

SUBSTRATE AS NECESSARY TO

MATCH EXISTING CONFIGURATION

AND IN ACCORDANCE WITH SMACNA

GUIDELINES.

INSTALL NEW

STANDING SEAM

TIN/ZINC COATED

COPPER ROOF

ON CUPOLA.

REPAIR ANY DAMAGED

STEPPED FLASHING AT BASE OF

CHIMNEY RESULTING FROM

DEMOLITION OF EXISTING

ROOF. (TYP.)

REINSTALL TWO

ROWS OF EXISTING

SNOW GUARDS

WHERE SHOWN.

(TYP.)

REPLACE ALL GUTTERS AND

DOWNSPOUTS TO MATCH

EXISTING. (TYP.)

AutoCAD SHX Text

144 CONSTITUTION AVE, NE WASHINGTON, DC

AutoCAD SHX Text

REHABILITATE BELMONT-PAUL MONUMENT

AutoCAD SHX Text

NATIONAL MALL AND MEMORIAL PARKS (NAMA)

AutoCAD SHX Text 11/30/20

AutoCAD SHX Text

NATIONAL PARK SERVICE - NATIONAL CAPITAL REGION

AutoCAD SHX Text

DESIGN AND PROJECT MANAGEMENT

AutoCAD SHX Text

UNITED STATES

AutoCAD SHX Text

OF

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DWG. NO.

AutoCAD SHX Text

DATE

AutoCAD SHX Text

DEPARTMENT OF THE INTERIOR

AutoCAD SHX Text

SUB SHEET NUMBER

AutoCAD SHX Text

TITLE OF DRAWING

AutoCAD SHX Text Mark

AutoCAD SHX Text Sheet

AutoCAD SHX Text Initial

AutoCAD SHX Text Date

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DESIGNED

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

CHECKED

AutoCAD SHX Text

TITLE OF PROJECT

AutoCAD SHX Text

NAME OF PARK

AutoCAD SHX Text

LOCATION WITHIN PARK

AutoCAD SHX Text

BEPA ROOF CD PHASE II

AutoCAD SHX Text

RJ

AutoCAD SHX Text

RJ

AutoCAD SHX Text

CD

AutoCAD SHX Text PMIS No.

AutoCAD SHX Text 310286

AutoCAD SHX Text

AutoCAD SHX Text

MATCHLINE SEE 1/A202

AutoCAD SHX Text

MATCH LINE

AutoCAD SHX Text A201

AutoCAD SHX Text

EAST ELEVATION - SOUTH END

AutoCAD SHX Text

SCALE A

AutoCAD SHX Text A201

AutoCAD SHX Text

AutoCAD SHX Text

EAST ELEVATION - SOUTH END

AutoCAD SHX Text

SCALE A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SCALE OF FEET

AutoCAD SHX Text A300

AutoCAD SHX Text

AutoCAD SHX Text

TYP

EDGE OF ROOF

ROOF PEAK

NORTH EXTERIOR

TERRACE

TOP OF DORMER

ROOF TERRACE

SHEET NOTES

1. REFERENCE ROOF PLAN FOR ADDITIONAL WORK

NOT SHOWN ON ELEVATIONS.

2. PAINT NEW STANDING SEAM TIN/ZINC COATED

COPPER ROOF.

3. REPLACE ALL GUTTERS AND DOWNSPOUTS TO

MATCH EXISTING.

4. CONTRACTOR TO VERIFY ALL DIMS IN FIELD.

REPAIR ANY DAMAGED

STEPPED FLASHING AT BASE OF

CHIMNEY RESULTING FROM

DEMOLITION OF EXISTING ROOF.

(TYP.)

REPAIR ANY DAMAGED

STEPPED FLASHING AT

BASE OF CHIMNEY

RESULTING FROM

DEMOLITION OF EXISTING

ROOF. (TYP.)

REINSTALL TWO

ROWS OF EXISTING

SNOW GUARDS

WHERE SHOWN. (TYP.)

INSTALL NEW STANDING SEAM

TIN/ZINC COATED COPPER

ROOF AND SUBSTRATE AS

NECESSARY TO MATCH

EXISTING CONFIGURATION

AND IN ACCORDANCE WITH

SMACNA GUIDELINES.

INSTALL NEW STANDING SEAM

TIN/ZINC COATED COPPER

ROOF AND SUBSTRATE AS

NECESSARY TO MATCH

EXISTING CONFIGURATION AND

IN ACCORDANCE WITH SMACNA

GUIDELINES.

REPLACE ALL

GUTTERS AND

DOWNSPOUTS

TO MATCH

EXISTING. (TYP.)

AutoCAD SHX Text

144 CONSTITUTION AVE, NE WASHINGTON, DC

AutoCAD SHX Text

REHABILITATE BELMONT-PAUL MONUMENT

AutoCAD SHX Text

NATIONAL MALL AND MEMORIAL PARKS (NAMA)

AutoCAD SHX Text 11/30/20

AutoCAD SHX Text

NATIONAL PARK SERVICE - NATIONAL CAPITAL REGION

AutoCAD SHX Text

DESIGN AND PROJECT MANAGEMENT

AutoCAD SHX Text

UNITED STATES

AutoCAD SHX Text

OF

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DWG. NO.

AutoCAD SHX Text

DATE

AutoCAD SHX Text

DEPARTMENT OF THE INTERIOR

AutoCAD SHX Text

SUB SHEET NUMBER

AutoCAD SHX Text

TITLE OF DRAWING

AutoCAD SHX Text Mark

AutoCAD SHX Text Sheet

AutoCAD SHX Text Initial

AutoCAD SHX Text Date

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DESIGNED

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

CHECKED

AutoCAD SHX Text

TITLE OF PROJECT

AutoCAD SHX Text

NAME OF PARK

AutoCAD SHX Text

LOCATION WITHIN PARK

AutoCAD SHX Text

BEPA ROOF CD PHASE II

AutoCAD SHX Text

RJ

AutoCAD SHX Text

RJ

AutoCAD SHX Text

CD

AutoCAD SHX Text PMIS No.

AutoCAD SHX Text 310286

AutoCAD SHX Text

AutoCAD SHX Text A203

AutoCAD SHX Text

NORTH ELEVATION

AutoCAD SHX Text

SCALE A

AutoCAD SHX Text A203

AutoCAD SHX Text

AutoCAD SHX Text

NORTH ELEVATION

AutoCAD SHX Text

SCALE A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SCALE OF FEET

AutoCAD SHX Text

AutoCAD SHX Text A300

AutoCAD SHX Text

AutoCAD SHX Text A300

EDGE OF ROOF

ROOF PEAK

GRADE

THRESHOLD

TOP OF CHIMNEY

SHEET NOTES

1. REFERENCE ROOF PLAN FOR ADDITIONAL WORK

NOT SHOWN ON ELEVATIONS.

2. PAINT NEW STANDING SEAM TIN/ZINC COATED

COPPER ROOF.

3. REPLACE ALL GUTTERS AND DOWNSPOUTS TO

MATCH EXISTING.

4. CONTRACTOR TO VERIFY ALL DIMS IN FIELD.

INSTALL STANDING SEAM

TIN/ZINC COATED COPPER

ROOF AND SUBSTRATE AS

NECESSARY TO MATCH

EXISTING CONFIGURATION AND

IN ACCORDANCE WITH SMACNA

GUIDELINES. (TYP.)

INSTALL STANDING SEAM

TIN/ZINC COATED COPPER

ROOF AND SUBSTRATE AS

NECESSARY TO MATCH

EXISTING CONFIGURATION

AND IN ACCORDANCE WITH

SMACNA GUIDELINES. (TYP.)

REINSTALL TWO

ROWS OF EXISTING

SNOW GUARDS

WHERE SHOWN.

(TYP.)

REPAIR ANY

DAMAGED STEPPED

FLASHING AT BASE

OF CHIMNEY

RESULTING FROM

DEMOLITION OF

EXISTING ROOF.

(TYP.)

INSTALL STANDING SEAM TIN/ZINC

COATED COPPER ROOF AND

SUBSTRATE AS NECESSARY TO

MATCH EXISTING CONFIGURATION

AND IN ACCORDANCE WITH

SMACNA GUIDELINES. (TYP.)

REPLACE ALL

GUTTERS AND

DOWNSPOUTS

TO MATCH

EXISTING.

(TYP.)

AutoCAD SHX Text

144 CONSTITUTION AVE, NE WASHINGTON, DC

AutoCAD SHX Text

REHABILITATE BELMONT-PAUL MONUMENT

AutoCAD SHX Text

NATIONAL MALL AND MEMORIAL PARKS (NAMA)

AutoCAD SHX Text 11/30/20

AutoCAD SHX Text

NATIONAL PARK SERVICE - NATIONAL CAPITAL REGION

AutoCAD SHX Text

DESIGN AND PROJECT MANAGEMENT

AutoCAD SHX Text

UNITED STATES

AutoCAD SHX Text

OF

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DWG. NO.

AutoCAD SHX Text

DATE

AutoCAD SHX Text

DEPARTMENT OF THE INTERIOR

AutoCAD SHX Text

SUB SHEET NUMBER

AutoCAD SHX Text

TITLE OF DRAWING

AutoCAD SHX Text Mark

AutoCAD SHX Text Sheet

AutoCAD SHX Text Initial

AutoCAD SHX Text Date

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DESIGNED

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

CHECKED

AutoCAD SHX Text

TITLE OF PROJECT

AutoCAD SHX Text

NAME OF PARK

AutoCAD SHX Text

LOCATION WITHIN PARK

AutoCAD SHX Text

BEPA ROOF CD PHASE II

AutoCAD SHX Text

RJ

AutoCAD SHX Text

RJ

AutoCAD SHX Text

CD

AutoCAD SHX Text PMIS No.

AutoCAD SHX Text 310286

AutoCAD SHX Text

AutoCAD SHX Text

MATCHLINE SEE 1/A205

AutoCAD SHX Text

MATCH LINE

AutoCAD SHX Text A204

AutoCAD SHX Text

WEST ELEVATION - SOUTH END

AutoCAD SHX Text

SCALE A

AutoCAD SHX Text A204

AutoCAD SHX Text

AutoCAD SHX Text

WEST ELEVATION - SOUTH END

AutoCAD SHX Text

SCALE A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SCALE OF FEET

EDGE OF ROOF

ROOF PEAK

NORTH EXTERIOR TERRACE

TOP OF CHIMNEY

REPAIR ANY DAMAGED STEPPED

FLASHING AT BASE OF CHIMNEY

RESULTING FROM DEMOLITION

OF EXISTING ROOF. (TYP.)

INSTALL NEW STANDING SEAM

TIN/ZINC COATED COPPER ROOF AND

SUBSTRATE AS NECESSARY TO MATCH

EXISTING CONFIGURATION AND IN

ACCORDANCE WITH SMACNA

GUIDELINES.

REINSTALL TWO ROWS OF

EXISTING SNOW GUARDS

WHERE SHOWN. (TYP.)

SHEET NOTES

1. REFERENCE ROOF PLAN FOR ADDITIONAL WORK

NOT SHOWN ON ELEVATIONS.

2. PAINT NEW STANDING SEAM TIN/ZINC COATED

COPPER ROOF.

3. REPLACE ALL GUTTERS AND DOWNSPOUTS TO

MATCH EXISTING.

4. CONTRACTOR TO VERIFY ALL DIMS IN FIELD.

REPLACE ALL

GUTTERS AND

DOWNSPOUTS TO

MATCH EXISTING.

(TYP.)

AutoCAD SHX Text

144 CONSTITUTION AVE, NE WASHINGTON, DC

AutoCAD SHX Text

REHABILITATE BELMONT-PAUL MONUMENT

AutoCAD SHX Text

NATIONAL MALL AND MEMORIAL PARKS (NAMA)

AutoCAD SHX Text 11/30/20

AutoCAD SHX Text

NATIONAL PARK SERVICE - NATIONAL CAPITAL REGION

AutoCAD SHX Text

DESIGN AND PROJECT MANAGEMENT

AutoCAD SHX Text

UNITED STATES

AutoCAD SHX Text

OF

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DWG. NO.

AutoCAD SHX Text

DATE

AutoCAD SHX Text

DEPARTMENT OF THE INTERIOR

AutoCAD SHX Text

SUB SHEET NUMBER

AutoCAD SHX Text

TITLE OF DRAWING

AutoCAD SHX Text Mark

AutoCAD SHX Text Sheet

AutoCAD SHX Text Initial

AutoCAD SHX Text Date

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DESIGNED

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

CHECKED

AutoCAD SHX Text

TITLE OF PROJECT

AutoCAD SHX Text

NAME OF PARK

AutoCAD SHX Text

LOCATION WITHIN PARK

AutoCAD SHX Text

BEPA ROOF CD PHASE II

AutoCAD SHX Text

RJ

AutoCAD SHX Text

RJ

AutoCAD SHX Text

CD

AutoCAD SHX Text PMIS No.

AutoCAD SHX Text 310286

AutoCAD SHX Text

AutoCAD SHX Text

MATCHLINE SEE 1/A204

AutoCAD SHX Text

MATCH LINE

AutoCAD SHX Text A205

AutoCAD SHX Text

WEST ELEVATION - NORTH END

AutoCAD SHX Text

SCALE A

AutoCAD SHX Text A205

AutoCAD SHX Text

AutoCAD SHX Text

WEST ELEVATION - NORTH END

AutoCAD SHX Text

SCALE A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SCALE OF FEET

8" M

IN

8" MIN

01BC15 TRANSVERSE SEAM-STEEP SLOPE-B

2" min.

" min.

01BC15 TRANSVERSE SEAM - SHALLOW SLOPE

4" min.

" min.

01BC26 DOUBLE LOCK B METHOD 2

01 BC 01a FIXED CLEAT

01BC27 METHOD 2 DOUBLE LOCK-1

E x t e n d

A b o v e

01BC28 METHOD 2 DOUBLE LOCK-1

01BC29 METHOD 2-DOUBLE LOCK-3

01BC30 METHOD 2-DOUBLE LOCK-4

01BC13 STANDING SEAM-4

01BC12 STANDING SEAM-3

01BC11 STANDING SEAM-2

01BC10 STANDING SEAM-1

H e i g h t o f

S e a m

STANDING SEAM

ROOF CONSTRUCTION:

STEP 1

STEP 2

STEP 3

STEP 4

TRANSVERSE SEAM

ROOF CONSTRUCTION:

STEP 1

STEP 2

STEP 3

STEP 4

POWDER COATED

STAINLESS STEEL

SNOW GUARDS

STANDING

SEAM ROOF

STANDING SEAM TIN/ZINC COATED COPPER ROOF

PROVIDE CLEAT

NEW STEPED FLASHING AROUND

BASE OF CHIMNEY

REGLET AT EXISTING JOINT

IN MASONRY WALL

SEALANT

ROOF SUBSTRATE

8" MIN.

10" MIN

12"

CONTINUOUS

VALLEY FLASHING

STANDING SEAM

TIN/ZINC COATED

COPPER ROOF

ROOF SUBSTRATE

CLEAT

CONTINUOUS

SOLDERED LOCK

STRIP

NEW STANDING SEAM

TIN/ZINC COATED

COPPER ROOF

SUBSTRATE AND BLOCKING

REPLACE COUNTERFLASHING AT

BASE OF DORMER WINDOW. TIE

INTO STANDING SEAM TIN/ZINC

COATED COPPER ROOF.

REPLACE WINDOW SILLS IF NECESSARY.

WINDOW TO BE REMOVED AND REINSTALLED

AS NEEDED FOR FLASHING REPLACEMENT

ROOF SUBSTRATE

REPAIR STEPPED COUNTERFLASHING

ALONG BASE OF DORMER WINDOW.

TIE INTO STANDING SEAM TIN/ZINC

COATED COPPER ROOF

STANDING SEAM

TIN/ZINC COATED

COPPER ROOF

DORMER SUBSTRATE

EXISTING SIDING

PROVIDE CLEAT

PROVIDE SELF-ADHERING

SHEET UNDERLAYMENT

AutoCAD SHX Text

144 CONSTITUTION AVE, NE WASHINGTON, DC

AutoCAD SHX Text

REHABILITATE BELMONT-PAUL MONUMENT

AutoCAD SHX Text

NATIONAL MALL AND MEMORIAL PARKS (NAMA)

AutoCAD SHX Text 11/30/20

AutoCAD SHX Text

NATIONAL PARK SERVICE - NATIONAL CAPITAL REGION

AutoCAD SHX Text

DESIGN AND PROJECT MANAGEMENT

AutoCAD SHX Text

UNITED STATES

AutoCAD SHX Text

OF

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DWG. NO.

AutoCAD SHX Text

DATE

AutoCAD SHX Text

DEPARTMENT OF THE INTERIOR

AutoCAD SHX Text

SUB SHEET NUMBER

AutoCAD SHX Text

TITLE OF DRAWING

AutoCAD SHX Text Mark

AutoCAD SHX Text Sheet

AutoCAD SHX Text Initial

AutoCAD SHX Text Date

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DESIGNED

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

CHECKED

AutoCAD SHX Text

TITLE OF PROJECT

AutoCAD SHX Text

NAME OF PARK

AutoCAD SHX Text

LOCATION WITHIN PARK

A…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .