This solicitation is for the construction of a Visitor's Center at the Herbert R. Temple Jr. Army National Guard Readiness Center in Arlington, Virginia. The project involves work in civil, architectural, security, structural, plumbing, mechanical, and electrical disciplines. The National Guard Bureau plans to construct the Visitor's Center building within the installation fence line. The period of performance is 425 calendar days from notice to proceed. The estimated construction magnitude is between $1M and $5M. The primary NAICS code is 236220 for commercial and institutional building construction. The written solicitation, specifications and drawings are attached for prospective offerors.
View the file
Other files
Show all 28
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1. CLASSIFICATION OF BUILDING
RISK CATEGORY (UFC 3-301-01 TABLE 2-2 AND OWNER DIRECTION) II
2. FLOOR LIVE LOADS UNIFORM CONCENTRATED
OFFICES 50 PSF 2000 LB
VESTIBULE / LOBBIES AND CORRIDORS 100 PSF 2000 LB
TOILETS 75 PSF
BREAK ROOM 100 PSF
MECHANICAL / IT ROOM 150 PSF
CONCENTRATED LOAD APPLIED OVER 2'-6" x 2'-6" AREA.
REDUCTION OF FLOOR LIVE LOAD HAS NOT BEEN UTILIZED.
3. ROOF LIVE LOADS
MINIMUM ROOF LIVE LOAD 20 PSF 300 LB
CONCENTRATED LOAD APPLIED OVER 2'-6" x 2'-6" AREA.
REDUCTION OF MINIMUM ROOF LIVE LOAD HAS NOT BEEN UTILIZED.
4. SUPERIMPOSED DEAD LOADS
ROOF 20 PSF
5. ROOF SNOW LOAD
GROUND SNOW LOAD (Pg) 25 PSF (PER STRUCTURAL LOAD DATA TOOL
IN ACCORDANCE WITH UFC 3-301-01)
IMPORTANCE FACTOR (ls) 1.0 EXPOSURE FACTOR (Ce) 1.0 THERMAL FACTOR (Ct) 1.0 FLAT ROOF SNOW LOAD (Pf = 0.7 x Ce x Ct x ls x Pg) 17.5 PSF MINIMUM Pf FOR Pg > 20 PSF
Pf min = 20 x I 20.0 PSF SLOPED ROOF SNOW LOAD (Ps = Cs x Pf) 17.5 PSF
6. WIND DESIGN DATA
ULTIMATE DESIGN WIND SPEED (3 SECOND GUST) 111 MPH (PER STRUCTURAL LOAD DATA TOOL
IN ACCORDANCE WITH UFC 3-301-01)
NOMINAL DESIGN WIND SPEED (3 SECOND GUST) 86 MPH
EXPOSURE B
INTERNAL PRESSURE COEFFICIENT (GCpi) ±0.18 (ENCLOSED)
COMPONENTS AND CLADDING WIND PRESSURE PER IBC & ASCE7
7. SEISMIC DESIGN DATA
SEISMIC DESIGN CATEGORY B
SEISMIC IMPORTANCE FACTOR (le) 1.00
SITE CLASS E
MAPPED SPECTRAL RESPONSE ACCELERATIONS (SEISMIC ACCELERATIONS PER STRUCTURAL LOAD
DATA TOOL IN ACCORDANCE WITH UFC 3-301-01)
(Ss) 0.134 (S1) 0.043
DESIGN SPECTRAL RESPONSE ACCELERATIONS
(Sds) 0.214 (Sd1) 0.120
BASIC SEISMIC FORCE RESISTING SYSTEM: BEARING WALL SYSTEM
INTERMEDIATE REINFORCED MASONRY SHEAR WALLS
ALL STEEL SYSTEMS ARE: SYSTEMS NOT SPECIFICALLY DETAILED FOR SEISMIC
RESISTANCE
RESPONSE MODIFICATION COEFFICIENT (R) 3.5
SYSTEM OVERSTRENGTH FACTOR 2.5
DEFLECTION AMPLIFICATION FACTOR 2.25
SEISMIC RESPONSE COEFFICIENT (Cs) 0.061 DESIGN BASE SHEAR (V = Cs x W) 0.061W
ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE PROCEDURE
1. FOUNDATIONS ARE DESIGNED TO BEAR ON ORIGINAL UNDISTURBED SOIL OR CONTROLLED COMPACTED FILL WITH AN ALLOWABLE BEARING CAPACITY OF 2,000 PSF, IN ACCORDANCE WITH THE GEOTECHNICAL
ENGINEERING REPORT PREPARED BY TIMMONS GROUP, DATED FEBRUARY 28, 2020.
2. THE GEOTECHNICAL ENGINEER FOR THE OWNERS TESTING AGENCY SHALL VERIFY BEARING CAPACITY
AND SUITABILITY OF SUBGRADE PRIOR TO PLACING FOUNDATIONS AND GRADE SLABS.
3. SELECT AND PLACE CONTROLLED COMPACTED FILL UNDER DIRECT SUPERVISION OF THE GEOTECHNICAL
ENGINEER FOR THE OWNERS TESTING AGENCY.
4. FOOTING STEPS FOR UNDERSLAB UTILITIES INDICATED ON FOUNDATION PLANS SHALL BE CONSIDERED
APPROXIMATE. COORDINATE FOOTINGS WITH ACTUAL LOCATION, SIZE AND INVERT OF ALL
UNDERGROUND PIPE (AND CONDUIT). REFER TO "FOOTING STEP" DETAIL TO STEP WALL FOOTING DOWN TO ALLOW UNDERSLAB PIPING TO PASS ABOVE THE FOOTING. ALTERNATELY, REFER TO "FOOTING SLEEVE" AND "PIPE TRENCH BACKFILL AT FOOTING" DETAILS TO ALLOW UNDERSLAB PIPING TO PASS
BELOW THE TOP OF THE WALL FOOTING.
5. AVOID INFLUENCE OF PIPE TRENCH PARALLEL TO WALL FOOTING AND / OR ADJACENT TO COLUMN
FOOTING. REFER TO "TRENCH LOCATION DETAIL".
6. PROTECT FOOTINGS AND GRADE SLABS FROM FROST HEAVE UNTIL BUILDING IS PERMANENTLY
ENCLOSED.
7. BRACE WALLS PLUMB WHICH ARE SUBJECTED TO UNBALANCED BACKFILL UNTIL PERMANENTLY
STABILIZED BY STRUCTURE.
1. ALL CONCRETE WORK SHALL CONFORM TO THE REQUIREMENTS OF ACI 318/318R "BUILDING CODE
REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY".
2. ACCORDING TO LABORATORY TESTING INDICATED IN THE GEOTECHNICAL REPORT, SULFATE LEVELS IN THE EXISTING SOILS WERE REPORTED IN THE RANGE OF 179 PPM (PARTS PER MILLION). IN ACCORDANCE WITH ACI 318 STANDARDS, THESE SULFATE LEVELS PLACE THE EXISTING SOILS WITHIN THE VERY LOW END OF THE "MODERATE" SULFATE EXPOSURE CLASSIFICATION. VARIOUS MITIGATION TECHNIQUES HAVE BEEN INCORPORATED INTO THE CONCRETE MIX DESIGNS, IN ACCORDANCE WITH THE ACI 318 "MODERATE" SULFATE EXPOSURE CLASSIFICATION. REFER TO SPECIFICATION SECTION 033000 FOR REQUIREMENTS.
3. CONCRETE SHALL BE NORMAL WEIGHT AND SHALL OBTAIN ULTIMATE 28 DAY COMPRESSIVE STRENGTHS (F'c), AS FOLLOWS:
FOOTINGS 4000 PSI
SLAB-ON-GRADE 4000 PSI
PIERS AND WALLS 4000 PSI
4. ALL EXTERIOR CONCRETE SHALL BE AIR-ENTRAINED.
5. ALL CONCRETE BELOW GRADE AND IN CONTACT WITH GRADE SHALL CONTAIN TYPE V PORTLAND CEMENT PER RECOMMENDATION OF THE GEOTECHNICAL ENGINEERING REPORT DUE TO HIGH SULFATE LEVELS
WITHIN THE EXISTING SOIL.
6. REINFORCING STEEL SHALL BE AS FOLLOWS:
• REINFORCING BARS: ASTM A615, GRADE 60, DEFORMED
• WELDED WIRE FABRIC: ASTM A1064, SHEET TYPE ONLY
• WELDABLE REINFORCING BARS: ASTM A706 LOW ALLOW STEEL REINFORCING BARS, DEFORMED
• DEFORMED BAR ANCHORS (DBA) ASTM A1064, DEFORMED
• WELDING PER AWS D1.4 STRUCTURAL WELDING CODE - REINFORCING STEEL
1. ALL STRUCTURAL STEEL WORK SHALL CONFORM TO THE FOLLOWING AISC DOCUMENTS:
AISC 360 "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS"
AISC 303 "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES"
RCSC'S "SPECIFICATION FOR STRUCTURAL JOINTS USING HIGH STRENGTH BOLTS"
2. STRUCTURAL STEEL SHALL COMPLY WITH THE FOLLOWING SPECIFICATIONS:
WIDE FLANGE SHAPES AND ANGLES ASTM A992 (FY=50 KSI)
MISCELLANEOUS SHAPES, PLATES & BARS (TO 8" THICK) ASTM A36 (FY=36 KSI)
HOLLOW STRUCTURAL SECTIONS (HSS)
SQUARE & RECTANGLE ASTM A500, GRADE B (FY=50 KSI)
ROUND ASTM A500 GRADE B (FY=46 KSI)
PIPE ASTM A53, GRADE B (FY=35 KSI)
HIGH STRENGTH BOLTS (CONVENTIONAL) ASTM F3125 GRADE A325 OR A490 (TYPE 1)
WASHERS ASTM F436 (FLAT AND BEVELED)
HEAVY HEX NUTS ASTM A563
ANCHOR RODS ASTM F1554, GR. 36
WELDING ELECTRODES E70 (LOW HYDROGEN)
HEADED SHEAR STUDS AWS D1.1 CLAUSE 7, TYPE B (FY=51 KSI)
THREADED ROD ASTM A36
3. UNLESS NOTED OTHERWISE, CONNECTIONS SHALL BE DESIGNED IN ACCORDANCE WITH AISC MANUAL OF STEEL CONSTRUCTION, AS SIMPLE CONNECTIONS USING ALLOWABLE STRENGTH DESIGN (ASD). CONNECTIONS FOR NON-COMPOSITE BEAMS SHALL BE DESIGNED FOR THE UNIFORM LOAD CAPACITY INDICATED IN THE
ALLOWABLE UNIFORM LOAD TABLES, PART 3, OF THE AISC MANUAL.
4. BOLTED JOINTS SHALL BE "SNUG TIGHTENED", UNLESS OTHERWISE INDICATED.
5. WELDING SHALL BE IN ACCORDANCE WITH AWS D1.1 "STRUCTURAL WELDING CODE - STEEL".
6. WHERE STRUCTURAL STEEL IS EXPOSED BELOW GRADE, PROVIDE MINIMUM 3" CONCRETE COVER OR COAT
WITH BITUMINOUS MASTIC.
7. STRUCTURAL STEEL EXPOSED TO WEATHER IN THE FINISHED WORK SHALL BE HOT DIPPED GALVANIZED IN
ACCORDANCE WITH ASTM A123, UNLESS NOTED OTHERWISE.
1. ALL STEEL DECK WORK SHALL CONFORM TO THE LATEST EDITION OF THE STEEL DECK INSTITUTE (SDI) "FLOOR DECK DESIGN MANUAL" AND "ROOF DECK DESIGN MANUAL", AND AMERICAN IRON AND STEEL INSTITUTE (AISI) "SPECIFICATION FOR THE DESIGN OF COLD FORMED STEEL STRUCTURAL MEMBERS".
2. WELDING SHALL BE IN ACCORDANCE WITH AWS D1.3, "STRUCTURAL WELDING CODE - SHEET STEEL".
3. PERMANENT LOADS SHALL NOT BE SUSPENDED FROM STEEL ROOF DECK UNLESS APPROVED BY
ENGINEER OF RECORD.
4. STEEL DECK UP TO 2" DEEP SHALL BE INSTALLED WITH A MINIMUM OF 3 CONTINUOUS SPANS, UNLESS NOTED OTHERWISE. STEEL DECK 3" DEEP OR GREATER SHALL BE INSTALLED WITH A MINIMUM OF 2 CONTINUOUS SPANS, UNLESS NOTED OTHERWISE. ANY LOCATIONS NOT MEETING THESE CONDITIONS
SHALL BE SPECIFICALLY IDENTIFIED ON THE STEEL DECK SHOP DRAWINGS.
5. REFER TO "STEEL DECK SCHEDULE" FOR DECK TYPES AND FASTENING REQUIREMENTS.
1. ALL MASONRY WORK SHALL CONFORM TO THE REQUIREMENTS OF TMS 402/602 "BUILDING CODE
REQUIREMENTS AND SPECIFICATION FOR MASONRY STRUCTURES ".
2. NET AREA COMPRESSIVE STRENGTH OF CONCRETE MASONRY(F'm), SHALL BE 2000 PSI, DETERMINED IN ACCORDANCE WITH THE UNIT STRENGTH METHOD PER TMS 602, UNLESS NOTED
OTHERWISE.
3. CONCRETE MASONRY UNITS (CMU) SHALL CONFORM TO ASTM C90, AND SHALL BE MADE WITH
LIGHTWEIGHT AGGREGATE.
4. MORTAR FOR CMU SHALL CONFORM TO ASTM C270, TYPE S, UNLESS NOTED OTHERWISE.
5. GROUT SHALL CONFORM TO ASTM C476 AND SHALL BE PROPORTIONED TO OBTAIN MINIMUM
ULTIMATE 28 DAY COMPRESSIVE STRENGTH OF 2500 PSI.
6. PLACE GROUT IN ACCORDANCE WITH TMS 602. ALLOW A MINIMUM OF 24 HOURS FOR MASONRY
TO SET PRIOR TO PLACING GROUT.
7. FILL COLLAR JOINTS OF COMPOSITE WALLS SOLID WITH MORTAR AS THE WALLS PROGRESS.
BOND WYTHES OF COMPOSITE WALLS TOGETHER USING HORIZONTAL JOINT REINFORCING @ 16"
ON CENTER, UNLESS NOTED OTHERWISE.
8. PROVIDE VERTICAL REINFORCING STEEL OF SIZE AND SPACING INDICATED. LAP SPLICE LENGTHS
SHALL BE AS FOLLOWS:
#4 BAR AND SMALLER 26 INCHES
#5 BAR 34 INCHES
#6 BAR 38 INCHES
#7 BAR 45 INCHES
9. PROVIDE POSITIONERS TO HOLD VERTICAL WALL REINFORCING STEEL IN PROPER ALIGNMENT.
10. REINFORCING STEEL SHALL COMPLY WITH ASTM A615, GRADE 60.
11. MASONRY WALLS OF HOLLOW UNITS WHICH CHANGE THICKNESS SHALL HAVE A CONTINUOUS
SOLID OR GROUT FILLED COURSE BELOW THE TRANSITION. IF WALL THICKNESS IS GREATER
ABOVE THE TRANSITION, THE COURSE ABOVE THE TRANSITION SHALL ALSO BE GROUTED SOLID.
12. FILL CMU CELLS WITH GROUT FROM TOP OF FOOTING TO TOP OF SLAB-ON-GRADE ELEVATION.
13. MASONRY WALL CONTROL JOINTS ARE NOT INDICATED ON THE STRUCTURAL DRAWINGS. REFER
TO ARCHITECTURAL DRAWINGS FOR JOINT LOCATIONS AND DETAILS. COORDINATE JOINT
LOCATIONS TO AVOID BEAM BEARING LOCATIONS.
1. INSTALL ALL ANCHORS IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED PROCEDURES AT NOT LESS THAN THE MINIMUM EDGE DISTANCES INDICATED IN THE MANUFACTURER'S LITERATURE. SUBMIT MANUFACTURER'S
PRODUCT DATA FOR REVIEW BY THE ARCHITECT.
2. ALL ANCHORS (INCLUDING THREADED RODS, NUTS, WASHERS) SHALL BE ZINC PLATED IN ACCORDANCE WITH
ASTM B633, FOR SERVICE CONDITION SC-1.
3. SCREW ANCHORS SHALL BE ONE OF THE FOLLOWING:
SCREW-BOLT +, BY DEWALT
TITEN HD, BY SIMPSON STRONG-TIE ANCHORING SYSTEMS
KWIK HUS-EZ, BY HILTI
HOLE DIAMETER THROUGH STEEL MEMBER SHALL BE 1/8 INCH LARGER THAN NOMINAL DIAMETER OF ANCHOR.
MINIMUM SCREW ANCHOR EMBEDMENTS SHALL BE AS FOLLOWS, UNO:
4" EMBEDMENT FOR 1/2" DIAMETER ANCHOR
5" EMBEDMENT FOR 5/8" DIAMETER ANCHOR
6" EMBEDMENT FOR 3/4" DIAMETER ANCHOR
4. ADHESIVE ANCHORS SHALL CONSIST OF THREADED ROD (ASTM A36), HEX NUT (ASTM A563), WASHER (ASTM F436), AND ADHESIVE (TYPE PER NOTES A, B OR C BELOW).
ADHESIVE DOWELS SHALL CONSIST OF DEFORMED REINFORCING BAR (ASTM A615, GRADE 60) AND ADHESIVE
(TYPE PER NOTE A BELOW)
A. "ADHESIVE ANCHORS" OR "ADHESIVE DOWELS" INSTALLED IN SOLID CONCRETE SHALL UTILIZE ONE OF
THE FOLLOWING ADHESIVE SYSTEMS, OR APPROVED EQUAL:
HYBRID (FAST CURE)
AC200+ BY DEWALT
ACRYLIC-TIE XP, BY SIMPSON STRONG-TIE ANCHORING SYSTEMS
HIT-HY 200, BY HILTI
EPOXY (SLOW CURE)
PURE 110+, BY DEWALT
SET-XP, BY SIMPSON STRONG-TIE ANCHORING SYSTEMS
HIT RE 500-V3 EPOXY ADHESIVE, BY HILTI
B. "ADHESIVE ANCHORS" INSTALLED IN SOLID GROUT FILLED CMU SHALL UTILIZE ONE OF THE FOLLOWING
ADHESIVE SYSTEMS, OR APPROVED EQUAL:
HIT-HY 270, BY HILTI
AC 100+ GOLD, BY DEWALT
ACRYLIC-TIE, BY SIMPSON STRONG-TIE ANCHORING SYSTEMS
C. "SCREEN TUBE ANCHORS" INSTALLED IN HOLLOW CMU SHALL UTILIZE ONE OF THE FOLLOWING ADHESIVE
SYSTEMS, OR APPROVED EQUAL:
HIT-HY 270, BY HILTI
AC 100+ GOLD, BY DEWALT
ACRYLIC-TIE, BY SIMPSON STRONG-TIE ANCHORING SYSTEMS
1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE 2018 INTERNATIONAL BUILDING CODE (2018 IBC), UNIFIED FACILITIES CRITERIA UFC 1-200-01 "DoD BUILDING CODE" AND UNIFIED FACILITIES CRITERIA UFC
3-301-01 "STRUCTURAL ENGINEERING".
2. THE STRUCTURAL DRAWINGS ARE INTENDED TO BE USED IN CONJUNCTION WITH THE ARCHITECTURAL
DRAWINGS AND THE DRAWINGS OF THE OTHER ENGINEERING DISCIPLINES.
3. THE CONTRACT DOCUMENTS ARE COMPLEMENTARY AND WHAT IS REQUIRED BY ONE SHALL BE AS BINDING AS IF REQUIRED BY ALL. IN THE CASE OF A CONFLICT, DISAGREEMENT, OR AMBIGUITY, PROVIDE THE BETTER QUAILITY. IN THE CASE OF A CONFLICT, DISAGREEMEENT, OR AMBIGUITY, PROVIDE THE
GREATER QUANITY OF WORK.
4. VERIFY AND COORDINATE MECHANICAL UNIT SUPPORTS AND OPENINGS WITH EQUIPMENT PURCHASED FOR THE PROJECT. COORDINATE REQUIREMENTS FOR SLEEVES, HANGERS, INSERTS, ANCHORS AND ALL
OTHER ITEMS TO BE SET IN STRUCTURAL WORK.
5. SPECIAL INSPECTIONS ARE REQUIRED BY THE 2018 IBC (SECTION 1704) AND UFC 1-200-01.
REFER TO THE STATEMENT OF SPECIAL INSPECTIONS PREPARED FOR THIS PROJECT AND THE PROJECT
SPECIFICATIONS FOR SPECIFIC INSPECTION REQUIREMENTS.
REFER TO SPECIFICATION SECTION 014000 FOR GENERAL INSPECTION REQUIREMENTS.
SECTION AND DETAIL 1
S2.1 S4.2
S2.2
S2.3
SECTION OR DETAIL NUMBER
DRAWING NUMBER WHERE SECTION OR DETAIL IS DRAWN
DRAWING NUMBER WHERE SECTION OR DETAIL IS CUT
ADDITIONAL DRAWING NUMBERS WHERE SECTION OR DETAIL IS CUT
S2.1
A
DETAIL WHERE CUT
DETAIL LETTER
DRAWING NUMBER WHERE DETAIL
IS DRAWN
S2.1
SECTION WHERE CUT
SECTION NUMBER
DRAWING NUMBER WHERE
SECTION IS DRAWN
(WHERE DRAWN)
EARTH
CAST IN PLACE CONCRETE
CLAY BRICK
SPLIT-FACE CONCRETE BLOCK
GROUT FILLED CONCRETE BLOCK
HOLLOW CONCRETE BLOCK
POROUS FILL OR GRANULAR BASE COURSE
STRUCTURAL MATERIALS LEGEND
PRECAST CONCRETE
JBE (+X'-X")
BP1, BP2 ...
BP-A, BP-B ...
P-1, P-2 ...
JS
SP
-X'-X"
WP
L1, L2 ...
X.X
(+X'-X")
(J)
(SL)
JOIST BEARING ELEVATION
BEAM BEARING PLATE
COLUMN BASE PLATE
CONCRETE PIER
JOIST SUBSTITUTE
SPECIAL JOIST
WALL FOOTING STEP
TOP OF FOOTING ELEVATION
WORK POINT
TOP OF SLAB ELEVATION
LINTEL
COLUMN FOOTING
TOP OF STEEL BEAM ELEVATION
INDICATES TOP OF STRUCTURAL MEMBER SHALL
BE IN SAME PLANE AS TOP OF JOIST
INDICATES TOP OF STRUCTURAL MEMBER SHALL
BE SLOPED
CENTERLINE
WFX.X WALL FOOTING
THICKENED SLAB
* STEEL JOIST BOTTOM CHORD EXTENSION,
WELDED
STEEL BEAM MOMENT CONNECTION
(EX) EXISTING
TRANSFER FORCE
TF
(X'-X")
H1, H2 ...
J1, J2 ...
T-1, T-2 ...
WOOD HEADER
WOOD JOIST
TRUSS
WP1, WP2 ... WOOD POST
CMU WALL REINFORCING SIZE AND SPACING
CHANGE IN SLAB ELEVATION
#5@48"
1. ALL STRUCTURAL COLD FORMED STEEL FRAMING (CFSF) SHALL COMPLY WITH AISI'S "NORTH AMERICAN
SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS".
2. CFSF-S (STRUCTURAL): INCLUDES ALL EXTERIOR WALLS, SOFFITS, BULKHEADS, RAFTERS, JOISTS AND CEILING JOISTS (IF SELF-SUPPORTING). PROVIDE ERECTION DRAWINGS AND DETAIL DRAWINGS. REFER TO SECTION 054000
FOR ADDITIONAL INFORMATION.
3. CFSF-NS (NON-STRUCTURAL): INCLUDES INTERIOR NON-LOAD BEARING STUD WALLS AND SUSPENDED CEILING
FRAMING SYSTEM. REFER TO SECTION 092216 FOR ADDITIONAL INFORMATION.
4. WALL FRAMING STUDS FOR EXTERIOR WALLS AROUND CANOPY COLUMNS SHALL BE 400S162-54 (4"-16GAGE) STEEL STUDS AT SPACING INDICATED IN PLAN. EXTERIOR WALL STUD ASSEMBLIES SHALL HAVE CONTINUOUS
BRIDGING CONNECTED TO EACH STUD @ 4'-0" OC MAX.
5. UNLESS NOTED OTHERWISE, THE MINIMUM CONNECTION OF EACH STUD SHALL BE EITHER (2) #10-16 SELF-DRILLING SCREWS OR 2 INCHES OF 1/8" FILLET WELDS. WHERE CONNECTION CLIP ANGLES ARE INDICATED, THEY SHALL BE 14 GAGE, 2"x2" MINIMUM.
6. STRUCTURAL SHEATHING SHALL BE ATTACHED WITH #10-16 SELF-DRILLING SCREWS AT 6" OC AT BOUNDARY EDGES AND CONTINUOUS PANELS. SCREW SPACING SHALL BE 12" OC WITHIN THE FIELD OF PANELS.
7. ALL FRAMING MEMBERS, BRIDGING AND ACCESSORIES SHALL BE FORMED FROM STEEL SHEET HAVING A
GALVANIZED COATING IN ACCORDANCE WITH ASTM A653.
8. UNLESS NOTED OTHERWISE, SPECIFIC CONNECTION REQUIREMENTS FOR COLD-FORMED FRAMING ARE AS
FOLLOWS:
STUD TO STUD (4) #10-16 SELF-DRILLING SCREWS
(BACK TO BACK CROSS)
STUD TO STUD W/ TIE (4) #10-16 SELF-DRILLING SCREWS EA SIDE
PLATE (ADJACENT)
STUD TO TRACK (1) #10-16 SELF-DRILLING SCREWS EA SIDE,
W/ STUD SECURELY SEATED IN TRACK
STUD TRACK TO BOX (2) #10-16 SEL-DRILLING SCREWS @ 16" OC
BEAM
STUD TRACK TO STEEL (2) 0.157" DIAM (X-U) PAFs THROUGH TRACK AT EA STUD
STUD TRACK TO (2) 0.157" DIAM (X-U) PAFs THROUGH TRACK AT EA STUD;
CONCRETE SLAB MINIMUM SPACING = 4"; MINIMUM EDGE DISTANCE = 3"
BOX BEAMS (2) 362S162-43 STUDS W/ (2) 362T125-43 TRACK (TOP & BOT);
CONN W/ (8) #10-16 SELF-DRILLING SCREWS @ 16" OC
14GA CLIP ANGLE (4) #10-16 SELF-DRILLING SCREWS
TO STUD
14GA CLIP ANGLE (2) 0.157" DIAM (X-U) PAFs AT EA CLIP
TO STEEL OR CONC
MINIMUM SPACING AND EDGE DISTANCE OF ALL SCREW FASTENERS = 1/2".
MINIMUM SPACING AND EDGE DISTANCE OF ALL POWDER ACTUATED FASTENERS IN STEEL = 1".
9. ALL C - SHAPED FRAMING MEMBERS SHALL HAVE A MINIMUM FLANGE WIDTH OF 1 5/8 INCHES.
10. MINIMUM YIELD STRENGTH SHALL BE AS FOLLOWS:
FY = 33,000 PSI 18 GAUGE AND 20 GAUGE
FY = 50,000 PSI 16 GAUGE, 14 GAUGE AND 12 GAUGE
1. CONTROLLED LOW STRENGTH MATERIAL (CLSM), ALSO REFERRED TO AS FLOWABLE FILL, MAY BE
SUBMITTED FOR APPROVAL AS A SUBSTITUTE FOR COMPACTED FILL AT FOUNDATION UNDERCUT
LOCATIONS. THE CLSM MIXTURE SHALL BE PROPORTIONED TO PRODUCE AN UNCONFINED COMPRESSIVE
STRENGTH OF 100 PSI MINIMUM TO 300 PSI MAXIMUM.
1. ALL STEEL JOIST WORK SHALL CONFORM TO THE LATEST EDITION OF THE STEEL JOIST INSTITUTE (SJI)
STANDARD SPECIFICATIONS.
2. STEEL JOISTS SHALL BE DESIGNED USING ALLOWABLE STRENGTH DESIGN (ASD).
3. PROVIDE JOIST BRIDGING IN ACCORDANCE WITH SJI SPECIFICATIONS, OSHA REQUIREMENTS, AND AS
REQUIRED BY JOIST DESIGN.
4. ROOF JOISTS AND BRIDGING SHALL BE DESIGNED FOR A NET UPLIFT OF 15 PSF.
5. SPECIAL JOISTS, INDICATED "SP" ON FRAMING PLANS, SHALL BE DESIGNED FOR CRITERIA INDICATED.
6. DETAILING AND ERECTION OF OPEN WEB STEEL JOISTS SHALL COMPLY WITH OSHA REQUIREMENTS.
7. STEEL ROOF JOISTS SHALL BE PROVIDED WITH NO CAMBER.
8. DESIGN ALL JOISTS (K, KCS, LH) FOR 500 LB CONCENTRATED LOAD (SERVICE LOAD) AT ALL DIAGONAL
STRUTS FRAMING TO JOIST CHORDS, UNLESS NOTED OTHERWISE.
9. TOP CHORD OF K-SERIES JOISTS SHALL BE DESIGNED FOR A POINT LOAD OF 200 POUNDS DEAD LOAD, LOCATED AT ANY POINT ALONG JOIST LENGTH, IN ADDITION TO ALL OTHER LOADS.
10. BOTTOM CHORD OF K-SERIES JOISTS SHALL BE DESIGNED FOR A POINT LOAD OF 200 POUNDS DEAD
LOAD, LOCATED AT ANY POINT ALONG JOIST LENGTH, IN ADDITION TO ALL OTHER LOADS.
11. TOP CHORD OF KCS AND LH SERIES JOISTS SHALL BE DESIGNED FOR A POINT LOAD OF 500 POUNDS DEAD LOAD, LOCATED AT ANY POINT ALONG JOIST LENGTH, IN ADDITION TO ALL OTHER LOADS.
12. BOTTOM CHORD OF KCS AND LH SERIES JOISTS SHALL BE DESIGNED FOR A POINT LOAD OF 500 POUNDS DEAD LOAD, LOCATED AT ANY POINT ALONG JOIST LENGTH, IN ADDITION TO ALL OTHER LOADS.
13. REFER TO “TYPICAL CONCENTRATED LOAD ON STEEL JOIST” DETAIL FOR REQUIREMENTS REGARDING
PIPE HANGERS AND OTHER EQUIPMENT LOADS.
14. STEEL JOISTS EXPOSED TO WEATHER IN THE FINISHED WORK SHALL BE PAINTED WITH A ZINC RICH
TNEMEC PAINT THAT MEETS THE REQUIREMENTS OF ASTM D 520 TYPE III.
DESIGN LOAD DATA
FOUNDATIONS
CONCRETE
STRUCTURAL STEEL
STEEL DECK
CONCRETE MASONRY (CMU)
POST INSTALLED ANCHORS & DOWELS
GENERAL
LEGEND FOR SECTION AND DETAIL MARKS
PLAN LEGEND
HSS HOLLOW STRUCTURAL SECTION
HT HEIGHT
IN INCH
INFO INFORMATION
INT INTERIOR
JBE JOIST BEARING ELEVATION
JS JOIST SUBSTITUTE
JST JOIST
JT JOINT
K KIP
LBS POUNDS
LF LINEAR FEET (FOOT)
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
M METER(S)
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM
MM MILLIMETER(S)
NOM NOMINAL
NS NON SHRINK
OC ON CENTER
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED CONTRACTOR
INSTALLED
OPNG OPENING
OPP OPPOSITE
PC CONC PRECAST CONCRETE
PEMB PRE-ENGINEERED METAL BUILDING
PFBC PRE-FABRICATED BUILDING COLUMN
PLF POUNDS PER LINEAR FOOT
POLY POLYETHYLENE
PPT PRESSURE PRESERVATIVE TREATED
PSF POUNDS PER SQUARE FOOT
R RADIUS
RD ROOF DRAIN
REF REFERENCE
REINF REINFORCING, REINFORCED
REQ'D REQUIRED
SIM SIMILAR
SL SLOPE
SOG SLAB ON GRADE
SPA SPACES
SS STAINLESS STEEL
STD STANDARD
STIFF STIFFENER
STRUCT STRUCTURAL
SUSP SUSPENDED
SYM SYMMETRY(RICAL)
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
TF TRANSFER FORCE
TOC TOP OF CONCRETE
TOS TOP OF STEEL
TOSL TOP OF SLAB
TOW TOP OF WALL
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VB VAPOR BARRIER
VERT VERTICAL
VR VAPOR RETARDER
WPT WORK POINT
WWF WELDED WIRE FABRIC
AB ANCHOR BOLT
AESS ARCHITECTURALLY EXPOSED
STRUCTURAL STEEL
AFF ABOVE FINISHED FLOOR
ALUM ALUMINUM
APPROX APPROXIMATE
ARCH ARCHITECTURAL, ARCHITECT
AVG AVERAGE
BLDG BUILDING
BM BEAM
BOT BOTTOM
BRG BEARING
BTWN BETWEEN
CANT CANTILEVER
CFSF COLD FORMED STEEL FRAMING
CIP CAST IN PLACE
CJ CONTROL JOINT
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONN CONNECTION
CONSTR CONSTRUCTION
CONT CONTINUOUS
CTR CENTER
DBA DEFORMED BAR ANCHOR
DBL DOUBLE
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DN DOWN
DWG DRAWING
EA EACH
EF EACH FACE
EJ EXPANSION JOINT
EL ELEVATION
ELECT ELECTRICAL
ELEV ELEVATOR
EOD EDGE OF DECK
EOS EDGE OF SLAB
EQ EQUAL
EW EACH WAY
EX EXISTING
EXP EXPANSION
EXT EXTERIOR
FD FLOOR DRAIN
FDN FOUNDATION
FF FINISHED FLOOR
FIN FINISHED
FLR FLOOR
FOB FACE OF BRICK
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FRMG FRAMING
FRT FIRE RETARDANT TREATED
FT FOOT
FTG FOOTING
GA GAGE
GALV GALVANIZED
GB GRADE BEAM
GC GENERAL CONTRACTOR
GRD GRADE
HD HEADED
HK HOOK
HORIZ HORIZONTAL
HS HIGH STRENGTH
STRUCTURAL ABBREVIATIONS
C
AO
M
M O N
W E
A LTH OF
V
I R G I N I
P
O
R O F
E
SS I
N
N
AL ENG
I
R E E
M O S E L E Y A R C H
IT
E C T S .C O M
JEFFREY S. O'BEIRNE
Lic. No. 036947
PROJECT NO:
DATE:
N
O R
F O
L K
S T
R E
E T
R
IC
H
M O
N D
V
A
P H
O N
E
-7
F
A X
-5
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
/2
/2
:3
:1
P M
GENERAL NOTES
AND LEGENDS
H . R
. T . J
R . A
R N
G R
EA
D
IN
ES
S C
EN
TE
R (T
A R
C ) V
IS
IT
O R
S C
EN
TE
R
S . G
E O
R G
E M
A S
O N
D R
A
R L
IN
G
T O
N
V A
S0.1
V A
F M
P N
-0
594303
MAY 27 2020
COLD FORMED STEEL FRAMING
FLOWABLE FILL
STEEL JOISTS
REVISIONS
DATE DESCRIPTION
C
B B
1 4
F F
E
9' - 9 5/8" 22' - 3 3/8" 15' - 9" 12' - 3 3/8"
S3.1
S3.1
S3.1
S3.1
S3.1
4.5
4.5
W 12x26
B P -B
W x2
B
W x2
B
H S S 5x5x1/4
B
-A
S3.1
4.0
S3.2
A
OPP
HAND
/8
/8
/8
/8
/8
/8
/8
73' - 4 5/8"2' - 3 5/8"
12' - 8 3/8" 58' - 4 5/8"
/2
/2
/2
/8
/2
/2
/2
/2
1' - 0 1/2"
2' - 5 7/8"
20' - 2 5/8" 28' - 10 1/8" 21' - 10"
8' - 6 3/4" 73' - 4 5/8"
/8
/8
S3.2
C
S3.2
D
S3.2
E
S3.2
F
S3.2
B
S3.2
A
G G
4.0
H S S 5x5x1/4
B
5.0
H S S 5x
5x 1/
B
D DH
S S 5x5x1/4
B
4.0
/2
FD FD
FD
CO
FD
CO
FD
-4' - 0"
NOTE BNOTE B -6' - 0"
-2' - 0"
NOTE C
NOTE C
NOTE C
NOTE C
#5 @ 8
#5 @ 8
#5 @ 8
4.9
-2' - 0"
-2' - 0"
-2' - 0"
N O
T E
D
NOTE D
BACK FACE OF 8" CMU
NOTE D
BACK FACE OF 8" CMU
NOTE D
S1.1
A
S3.1
NOTE E
RAIN LEADERRAIN LEADER DEPRESS SLAB AT
ENTRY MAT; COORD
W/ MAT MFR; REFER
TO ARCH DWGS
ENTRY MAT SHALL BE
PLACED ON TOP OF
GRADE SLAB (NO SLAB
DEPRESSION); COORD
W/ MAT MFR; REFER
TO ARCH DWGS
APPROXIMATE EDGE
OF EXISTING CONC
RETAINING WALL FTG
(FIELD VERIFY)
EXISTING CONC
RETAINING WALL
FACE OF EXISTING
CONC STEM WALL
ON TOP OF RETAINING
WALL ABOVE
APPROXIMATE EDGE
OF EXISTING CONC
RETAINING WALL FTG
NOTE A
APPROXIMATE EDGE
OF EXISTING CONC
RETAINING WALL FTG
(FIELD VERIFY)
C J
C J
CJ
C J
C J
C J
C J
CJ
CJ
C J
C J
C J
CJ
C J
CJ
-4' - 0"
-2' - 0"
S3.1
1' - 2"
-3' - 4"
WF5.0
WF5.0
/2
/4
1' - 0 1/2"
-2' - 0"
CO
-2' - 0"-2' - 0"
S1.1
S3.1
S3.1
AT
CURTAIN WALL
S3.1
S1.1
AT DEAL
TRAY
-4' - 8"
JBE (+13'-0"; 3 1/2" JST SEAT)
(4 1/2" JST SEAT)
JBE (+12'-4")
(3 1/2" JST SEAT)
JBE (+11'-4")
(3 1/2" JST SEAT)
JBE (+13'-0")
(5 3/4" JST SEAT)
JBE (+13'-0")
K
S L
K
S L
K
S L
K
S L
K
S L
A
C
B B
1 4
F F
E
W14x22 ( +10'-9 1/2" )
W14x30 ( +10'-9 1/2" )
W12x16 ( +10'-9 1/2" )
W14x22 (+11'-0")
W18x40 (+11'-0")
W10x12 (+11'-0")
W10x12 (+11'-0")
W12x16 (+11'-0")
W10x12 (+11'-0")
EQ EQ (5) EQ SPA = 22' - 3 3/8" 3 EQ SPA = 15' - 9"
(+11'-0")
W10x12
S3.1
OPEN
S3.1
S3.1
S3.1
S3.1
S3.1
S3.1
S3.1
S3.1
S3.1
W12x16 ( +11'-0" ) 7
O F
F S
E T
S3.1
S3.1
BOT OF ROOF DECK
AT COL WRAP
(+12'-4"; TYP OF 3)
DSS-1B
96 LBS
FAN F-1
26 LBS
RTU-1
2,000 LBS
NOTE C
G G
D
D
S3.1
S3.1
S3.1
S3.1
K
C S
S L
28K9 (SL) 2
K
C S
S L
K
C S
S L
24K7 (SL)
S3.1
NOTE B
NOTE A
ROOF HATCH;
ADDITIVE BID ITEM #2
FAN F-2
19 LBS
FULLY WELD END
OUTLOOKER TO
COL WEB; DESIGN
MOMENT CONN FOR
1 K-FT TOTAL LOAD
FULLY WELD END
OUTLOOKER TO
COL WEB; DESIGN
MOMENT CONN FOR
1 K-FT TOTAL LOAD
NOTE D
PROVIDE HSS FRAMING
AROUND COL WRAP
FOR DECK SUPPORT
(TYP OF 2 COLS)
NOTE E
NOTE E
L3 L2
L4
L4 L3
CONT L3 ACROSS
BOTH WINDOWS
L2 L2
L2
L2
L2
L1
L3
L2
NOTE F
CONT L3 ACROSS
BOTH WINDOWS
4"
OFFSET END OUTLOOKER
FROM W14 BEAM TO
ALLOW FOR CONN
RD
RD
RD
S3.1
NOTE G
NOTE GNOTE G
CONT L3 ACROSS
BOTH WINDOWS
NOTE H
(TYP OF 8 PILASTER
RETURN WALLS)
NOTE J
S3.1
4"
2 SPA = 8' - 9 1/8" 5 EQ SPA = 26' - 0 3/8" 5 EQ SPA = 21' - 10"
4"
4" 3 EQ SPA = 12' - 10 3/8"
8" CMU
GROUNTED SOLID
6" CMU
GROUTED SOLID
4" SOLID CMU
MORTAR COLLAR
JT SOLID
MORTAR COLLAR
JT SOLID
4" SOLID CMU
NOTE 2
8" CMU
GROUNTED SOLID
/8
1' - 3 3/4" (ADD BID ITEM #1)
6" CMU
GROUTED SOLID
NOTES: 1. ADDITIVE BID ITEM #1 INDICATED IN PLAN DETAILING.
2. 1 1/2" JOINT WITH RIGID INSULATION FOR THERMAL BREAK. REFER TO ARCH DWGS.
PROVIDE JOINT FROM FOUNDATION TO BELOW BOTTOM OF WALL TRIPLE BOND BEAM.
/8
(A D
D B
ID
I T
E M
/2
(A D
D B
ID
1' - 1 1/8" (BASE BID)
/8
(B A
S E
B
ID
/2
(B A
S E
B
ID
1 1/2"
BASE BID
FIN FLOOR
8" CMU
GROUTED SOLID
DOWELS SHALL MATCH
WALL REINF
GARDEN SOIL
REFER TO CIVIL DWGS
4" SOLID CMU
REFER TO ARCH DWGS
FOR CAVITY CONSTR
1' - 1 1/8"
REFER TO "WALL FOOTING
DETAIL" ON DWG S3.0.1
TOP OF FTG
REFER TO FDN PLAN
REFER TO FDN PLAN
MORTAR COLLAR
JOINT SOLID
(M A
X C
A V
IT
Y
ADDITIVE BID ITEM #1
FIN FLOOR
8" CMU
GROUTED SOLID
DOWELS SHALL MATCH
WALL REINF
GARDEN SOIL
REFER TO CIVIL DWGS
6" CMU
GROUTED SOLID
REFER TO ARCH DWGS
FOR CAVITY CONSTR
REFER TO "WALL FOOTING
DETAIL" ON DWG S3.0.1
TOP OF FTG
REFER TO FDN PLAN
MORTAR COLLAR
JOINT SOLID
(M A
X C
A V
IT
Y
PRECAST SILL
REFER TO ARCH DWGS
1' - 3 3/4"
REFER TO FDN PLAN
CURTAIN WALL
REFER TO ARCH DWGS
CURTAIN WALL
REFER TO ARCH DWGS
PRECAST SILL
REFER TO ARCH DWGS
1/2"
11 5/8" 11 5/8"
(+2'-6")
8x8 OPEN BOT BOND
BEAM W/ (2) #5 CONT
4" CUT COURSE
GROUTED SOLID
8" CMU
REFER TO FDN PLAN
FOR VERT REINF
EIFS
REFER TO ARCH DWGS
(+0'-8")
4" GROUND FACE CMU
REFER TO ARCH DWGS
CONT 5"x1/4" BRG PLATE W/ (2) 1/2" DIAM x 6" HEADED
STUDS (EQ SPACED);
COORD LENGTH OF PLATE
W/ TRAY MFR (18" +/-)
DEAL TRAY
REFER TO ARCH DWGS
CONT 1/4" BENT PLATE
BELOW TRAY; COORD
LENGTH OF PLATE W/
TRAY MFR
3/16 3-12
3/16
EACH END
STOREFRONT
REFER TO ARCH DWGS
(+2'-4"; TOP OF CMU)
9"
2 1/2"
COUNTER
REFER TO ARCH DWGS
C
AO
M
M O N
W E
A LTH OF
V
I R G I N I
P
O
R O F
E
SS I
N
N
AL ENG
I
R E E
M O S E L E Y A R C H
IT
E C T S .C O M
JEFFREY S. O'BEIRNE
Lic. No. 036947
PROJECT NO:
DATE:
N
O R
F O
L K
S T
R E
E T
R
IC
H
M O
N D
V
A
P H
O N
E
-7
X
-5
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
/2
/2
:3
:1
P M
FOUNDATION
AND ROOF
FRAMING PLANS
H . R
. T . J
R . A
R N
G R
EA
D
IN
ES
S C
EN
TE
R (T
A R
C ) V
IS
IT
O R
S C
EN
TE
R
S . G
E O
R G
E M
A S
O N
D R
A
R L
IN
G
T O
N
V A
S1.1
V A
F M
P N
-0
594303
MAY 27 2020
1/8" = 1'-0"
FOUNDATION PLAN
1/8" = 1'-0"
ROOF FRAMING PLAN
FOUNDATION PLAN NOTES:
1. FINISHED FIRST FLOOR ELEVATION = 219.00' = REFERENCE DATUM EL (+0'-0"). ALL
STRUCTURAL ELEVATIONS INDICATED ARE REFERENCED FROM THIS ELEVATION, UNO.
2. FLOOR CONSTRUCTION SHALL BE 4" NORMAL WEIGHT CONCRETE SLAB ON GRADE REINFORCED WITH 6x6-W2.9xW2.9 WWF (AT 1" FROM TOP OF SLAB) OVER VAPOR BARRIER OVER 6" GRANULAR BASE COURSE, UNO.
3. BASE COURSE SHALL BE A CLEAN, DENSELY-GRADED "CRUSHER RUN" MATERIAL WITH A BALANCED FINE CONTENT, SUCH AS VDOT 21A OR 21B STONE. THE BASE COURSE SHALL BE COMPACTED AND SHALL BE FINISHED TO A FLAT, SMOOTH, LOW-FRICTION SURFACE. COMPACTION SHALL BE MONITORED BY THE ON-SITE TESTING AGENCY. OPEN
GRADED STONE, SUCH AS #57 STONE, IS NOT ACCEPTABLE.
4. REFER TO "CONCRETE" NOTES ON DRAWING S0.1 FOR REQUIREMENTS TO MITIGATE SUFATE EXPOSURE FROM EXISTING
SOILS, AS INDICATED IN THE GEOTECHNICAL REPORT.
5. COORDINATE TOP OF CMU VENEER / BOTTOM OF EIFS WITH FINAL GRADE ELEVATIONS. REFER TO CIVIL DRAWINGS FOR GRADING PLAN. STEP CMU VENEER AS REQUIRED TO MAINTAIN A MINIMUM OF 6" FROM FINAL GRADE TO BOTTOM OF EIFS.
6. TOP OF ALL EXTERIOR FOOTINGS SHALL BE (-2'-0"), UNO.
7. ALL EXTERIOR WALL FOOTINGS SHALL BE WF2.5, UNO.
8. REINFORCE ALL EXTERIOR MASONRY WALLS WITH #5 AT 48" OC FULL WALL HEIGHT WITH EQUAL DOWELS TO FOOTING, UNO.
9. COORDINATE FOOTING STEPS WITH ALL UNDERSLAB UTILITIES. REFER TO FOUNDATION NOTE #4 ON DRAWING S0.1.
10. REFER TO DRAWING S0.1 FOR GENERAL NOTES, PLAN LEGEND, AND STRUCTURAL ABBREVIATIONS.
11. REFER TO DRAWINGS S3.0.1 AND S3.0.2 FOR TYPICAL FOUNDATION DETAILS AND SCHEDULES.
12. REFER TO DRAWING S4.0.1 FOR TYPICAL MASONRY WALL REINFORCING DETAILS.
ROOF FRAMING PLAN NOTES:
1. TOP OF STEEL BEAMS INDICATED THUS (+X'-X") ON PLAN SHALL BE REFERENCED FROM FINISHED FIRST FLOOR
ELEVATION.
2. STEEL ROOF DECK SHALL BE 1 1/2" WIDE RIB ROOF DECK (DECK TYPE 1), UNO. REFER TO STEEL DECK SCHEDULE ON DRAWING S4.0.1 FOR DECK TYPES INDICATED ON PLAN. REFER TO FRAMING PLAN AND ARCHITECTURAL AND
STRUCTURAL SECTIONS FOR EXTENT OF DECK TYPES.
3. REFER TO DRAWING S0.1 FOR GENERAL NOTES, PLAN LEGEND, AND STRUCTURAL ABBREVIATIONS.
4. REFER TO DRAWINGS S4.0.1 AND S4.0.2 FOR TYPICAL FRAMING DETAILS AND SCHEDULES.
5. REFER TO "ROOF OPENING SUPPORT DETAIL" ON DRAWING S.4.0.1 FOR ALL ROOF PENETRATION FRAMING REQUIREMENTS.
NOTE A: SAWCUT AND REMOVE PORTION OF EXISTING CONCRETE STEM WALL AND RETAINING WALL
BETWEEN EXISTING PRECAST PILASTER PANELS TO ELEVATION 8" BELOW EXISTING LEVEL 2
OF THE PARKING GARAGE.
NOTE B: CONCRETE FOUNDATIONS SHALL BE DROPPED AT PLAN SOUTH SIDE OF THE BUILDING DUE
TO THE DEPTH OF THE ADJACENT PARKING STRUCTURE BASEMENT FOUNDATIONS.
NOTE C: GROUT 10" CMU PILASTER SOLID AND REINFORCE WITH #5 @ 8" OC VERTICAL BARS.
NOTE A: PROVIDE CONTINUOUS 8x24 OPEN BOT BOND BEAM (WITH (2) #5 CONT EACH COURSE) WITH TOP AT (+15'-4") ACROSS ENTIRE LENGTH OF WALL. PROVIDE CONTINUOUS 8x24
OPEN BOT BOND BEAM (WITH (2) #5 CONT EACH COURSE) WITH BOTTOM AT (+10'-0")
ACROSS ENTIRE LENGTH OF FRONT PILASTER WALL. REFER TO SECTIONS 11/S3.1 AND
12/S3.1. PROVIDE BOTH BOND BEAMS CONTINUOUS FROM TOP OF PILASTER PLAN NORTH
AT COLUMN E2 (REFER TO PLAN DETAIL F/S3.2) TO END OF PILASTER PLAN SOUTH AT THE
END OF THE BUILDING (REFER TO PLAN DETAIL C/S3.2).
NOTE B: PROVIDE CONTINUOUS 8x24 OPEN BOT BOND BEAM (WITH (2) #5 CONT EACH COURSE)
WITH TOP AT (+9'-4") ACROSS ENTIRE LENGTH OF OPEN GARDEN CLOSURE WALL.
PROVIDE BOND BEAM FROM TOP OF PILASTER PLAN WEST AT THE END OF THE BUILDING
(REFER TO PLAN DETAIL C/S3.2) TO A LENGTH OF 2'-0" MINIMUM BEARING ONTO THE
BUILDING WALL AT THE OPPOSITE END.
NOTE C: REFER TO "RTU CURB SUPPORT DETAILS" ON DRAWING S4.0.2 FOR C6 CURB SUPPORT
REQUIREMENTS AND LOCATIONS NOT INDICATED ON PLAN.
NOTE D: MAINTAIN DIMENSION TO BACK FACE OF 8" CMU FOR BASE BIDE OR ADDITIVE BID ITEM #1.
NOTE D: PROVIDE L5x3-1/2x1/4 (LLV) FRAMING AROUND COLUMN WRAP FOR ROOF DECK SUPPORT.
1 1/2" = 1'-0"S1.1 S1.1
FOUNDATION WALL PLAN DETAIL AA
NOTE E: PROVIDE 1 1/2" JOINT WITH RIGID INSULATION FOR THERMAL BREAK. REFER TO ARCH DWGS.
PROVIDE JOINT FROM FOUNDATION TO BELOW BOTTOM OF WALL BOND BEAM. THERMAL
BREAK SHALL NOT CONTINUE THROUGH BOND BEAM.
NOTE F: WELD END OF BEAM AND PLATE LINTEL TO HSS COLUMN. PROVIDE SHEAR TAB CONN
FOR A TOTAL LOAD OF 5.5 KIPS.
NOTE E: COORDINATE LOCATION OF CANOPY RAIN LEADER WITHIN 8" CMU WALL. GROUT CELL
SOLID AROUND RAIN LEADER PIPE.
NOTE G: PROVIDE STOREFRONT / GLASS DOOR BRACING IN ACCORDANCE WITH TYPICAL DETAILS
ON DRAWING S4.0.1.
3/4" = 1'-0"S1.1 S1.1
SECTION1
NOTE H: PROVIDE 8x16 OPEN BOT BOND BEAM (WITH (2) #5 CONT EACH COURSE) AT EACH PILASTER RETURN WALL (TYPICAL OF 8 LOCATIONS). TOP OF ALL BOND BEAMS SHALL BE AT (+16'-0").
PROVIDE CORNER BARS IN BOND BEAMS THAT TIE INTO TRIPLE BOND BEAM REINFORCING
AT PERPENDICULAR WALL.
NOTE J: COORDINATE JOIST LOCATION WITH MASONRY WALL CONTROL JOINT. JOIST BEARING
PLATE SHALL NOT CROSS CONTROL JOINT.
1 1/2" = 1'-0"S1.1 S1.1
SECTION2
BELOW GRADE PIPING WITH
PIPE SLEEVE SIZED TO ALLOW
1" CLEARANCE ALL AROUND
PIPE. FILL SPACE WITH
COMPRESSIBLE MATERIAL
CONTINUOUS
REINFORCING
CONTINUOUS
REINFORCING
BACKFILL EXCAVATION WITH
FLOWABLE FILL OR CONTROLLED
COMPACTED FILL PRIOR TO
FOOTING PLACEMENT
REFER TO CIVIL OR
PLUMBING DWGS
FOR PIPE INVERTS
PIPE TRENCH BACKFILL AT FOOTINGFOOTING SLEEVE
(PIPE PLACED PRIOR TO FOOTING)
CONTINUOUS
REINFORCING
3" CLR, TYP
C L R
T
Y P
LONGITUDINAL
REINF
TOP OF FTG ELEVATION
INDICATED ON PLAN
FOOTING STEP PLAN AT CORNER PLAN AT INTERSECTION
M
IN
M
IN
1'
M
IN
M A
X
1' - 0" MIN
1' - 0" MIN
M A
X
H
(2 x H) MIN
CONSTRUCTION JOINT
WALL FOOTING FORMED KEY JOINTWALL FOOTING
WALL FOOTING
3" C
LR
C L R
3" CLR
2' - 0" LAP
C L R
SPLICE TOP BARS SIMILARLY
3' - 0" MIN
UTILITY TRENCH SHALL
NOT CROSS THIS PLANE
ADJACENT FOOTING TRENCH
SHALL NOT CROSS THIS PLANE
BOT OF FTG
COLUMN AND FOOTING
STEEL COLUMN
REFER TO FDN PLAN
REFER TO FDN
PLAN FOR TOP
OF FOOTING EL
FIN FLOOR
SEPARATE POUR
PROVIDE MIN 3" COVER
AROUND BASE PLATE
AND ANCHOR BOLTS
REFER TO COLUMN BASE
PLATE SCHEDULE
T H
IC
K
N E
S S
FOR FOOTING SIZE AND REINFORCING
REFER TO SPREAD FOOTING SCHEDULE
3" CLR
C L R
/2
N S
G R
O U
T
LONGITUDINAL
REINF
TRANSVERSE
REINFORCING
REFER TO FDN
PLAN FOR FTG
ELEVATION
MASONRY WALL
UNO
EQ
UNO
EQ
T H
IC
K
N E
S S
C L R
WIDTH
3" CLR
LONGITUDINAL
REINF
TRANSVERSE
REINFORCING
REFER TO FDN
PLAN FOR FTG
ELEVATION
MASONRY WALL
UNO
EQ
UNO
EQ
T H
IC
K
N E
S S
C L R
WIDTH
3" CLR
C L R
WITH TOP & BOT
REINFORCING
WITH BOT REINFORCING
BASE PLATE,
REFER TO SCHEDULE
ANCHOR RODS,
REFER TO
SCHEDULE
E M
B E
D M
E N
T P
R O
JE
C
T
IO
N A
S R
E Q
U
IR
E D
STANDARD BASE
MIN FILLET WELD
SIZE PER AISC
GAGE
L /2
L /2
L
G A
G E
W
W/2 W/2
COL &
PLATE
BP-A BP-B
COL &
PLATE
/2
/2
1 1/2" 1 1/2"
8 1/2"
4 1/4" 4 1/4"
C
AO
M
M O N
W E
A LTH OF
V
I R G I N I
P
O
R O F
E
SS I
N
N
AL ENG
I
R E E
M O S E L E Y A R C H
IT
E C T S .C O M
JEFFREY S. O'BEIRNE
Lic. No. 036947
PROJECT NO:
DATE:
N
O R
F O
L K
S T
R E
E T
R
IC
H
M O
N D
V
A
P H
O N
E
-7
X
-5
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
/2
/2
:3
:1
P M
TYPICAL
FOUNDATION
DETAILS
H . R
. T . J
R . A
R N
G R
EA
D
IN
ES
S C
EN
TE
R (T
A R
C ) V
IS
IT
O R
S C
EN
TE
R
S . G
E O
R G
E M
A S
O N
D R
A
R L
IN
G
T O
N
V A
S3.0.1
V A
F M
P N
-0
594303
MAY 27 2020
NO SCALE
WALL FOOTING DETAILS
NO SCALE
TRENCH LOCATION DETAIL
NO SCALE
STEEL COLUMN FOOTING DETAILS
NO SCALE
WALL FOOTING DETAILS
NO SCALE
COLUMN BASE PLATE DETAILS
COLUMN BASE PLATE SCHEDULE
MARK
BASE PLATE SIZE HEADED ANCHOR RODS
L W T SIZE EMBED GAGE
BP-A 1' - 0" 1' - 0" 3/4" (4) 3/4" DIAM 9" 9"
BP-B 1' - 6" 8 1/2" 3/4" (4) 3/4" DIAM 9" -
SPREAD FOOTING SCHEDULE
MARK
SIZE
REINFORCINGLENGTH WIDTH THICKNESS
4.0 4' - 0" 4' - 0" 1' - 0" (4) #5 EA WAY BOT
4.5 4' - 6" 3' - 6" 1' - 0" (5) #5 EA WAY BOT
4.9 5' - 0" 4' - 0" 1' - 0" (5) #5 BOT (SHORT); (6) #5 BOT (LONG)
5.0 5' - 0" 5' - 0" 1' - 0" (5) #5 EA WAY BOT
WALL FOOTING SCHEDULE
MARK WIDTH THICKNESS
REINFORCING (BOT, UNO)
LONGITUDINAL TRANSVERSE
WF2.5 2' - 6" 1' - 0" (3) #5 CONT #5 @ 48 OC BOT
WF5.0 5' - 0" 1' - 4" (6) #5 CONT #5 @ 12 OC BOT; #5 @ 18 OC TOP
SLAB EDGE
(2) #4 x 3'-0" AT
RE-ENTRANT CORNERS
LOCATED DIRECTLY BELOW
SLAB REINFORCING OR AT
MID-DEPTH OF SLAB
1"
2"
EDGE OF SLAB REFER
TO ARCH SECTIONS
1/2" EXPANSION JOINT
FILLER STRIP AT BOTH
ENDS OF OPENING
EXTERIOR
WALL
SLAB ON GRADE
BOND BREAK
#4 @ 12" OC
2'-0"
(1) #4
(1) #4 AT RE-ENTRANT
CORNER, EACH SIDE
3'-0"
1'-0"
2" C
LR
SMOOTH
DOWELS
MASONRY OPENING
PLAN AT EXTERIOR DOORS SECTION AT DOOR 02A ONLY
GROUT CMU SOLID
BELOW GRADE (TYP) DOWELS SHALL MATCH VERT
MORTAR COLLAR
JOINT SOLID
MORTAR COLLAR
JOINT SOLID
1' - 1 5/8"
FIN FLOOR
SITE SLAB
DOOR FRAME,
REFER TO ARCH
EQEQ
SECTION AT EXTERIOR DOORS
PLAN
REFER TO
(-2' - 0")
GROUT CMU SOLID
BELOW GRADE
GROUT CMU SOLID
BELOW GRADE
GROUT COLLAR
JOINT SOLID
REFER TO ARCH FOR
CAVITY INSULATION
DOWELS SHALL MATCH VERT
SITE SLAB
DOOR FRAME,
REFER TO ARCH
1/2" ISOLATION
JOINT FILLER STRIP
1/2"
FIN FLOOR
3/4" DIAM x 1'-4" GALV
SMOOTH DOWEL AT 12" OC,
GREASE ONE END OR USE
PAPER OR PLASTIC SLEEVE
REFER TO 'PLAN AT
EXTERIOR DOORS'
DETAIL
11 5/8"
1/2" ISOLATION JT
W/ FILLER STRIP
DOOR
THRESHOLD
VAPOR BARRIER
GRANULAR
BASE COURSE
WWF
REFER TO PLAN
S L A
B D
E P
R E
S S
IO
N
2 x SLAB THICKNESS
WWF
REFER TO PLAN
VAPOR BARRIER
GRANULAR BASE COURSE
SAWCUT JOINT 1/8" WIDE x
1/4 SLAB THICKNESS
SUPPORT WWF
CONTINUOUSLY @ 2'-6" OC
CUT AND REMOVE EVERY
OTHER WIRE AT JOINT
NOTES:
1. SAWCUT AS SOON AS CONCRETE WILL SUPPORT EQUIPMENT AND
EARLY ENOUGH TO PREVENT CRACKING. DO NOT DISLODGE
AGGREGATE.
2. CONSTRUCTION JOINT MAY REPLACE CONTROL JOINT.
3" 3"
JOINT SEALANT AS/IF
REQUIRED PER ARCH DWGS
CONTROL JOINT
WWF
REFER TO PLAN
VAPOR BARRIER
GRANULAR BASE COURSE
FORMED KEY JOINT
SUPPORT WWF
CONTINUOUSLY @ 2'-6" OC
CONSTRUCTION JOINT
NOTE 9
NOTE 7NOTE 2
NOTE 5
NOTE 5
NOTE 8
NOTE 8
NOTE 4 NOTE 4
NOTE 3
NOTE 6
NOTE 8
NOTE 1
NOTES:
1. PROVIDE CONTROL JOINTS IN SLABS ON GRADE WITHIN THE BUILDING SUCH THAT THE AREA BOUNDED BY
CONTROL JOINTS DOES NOT EXCEED 225 SQUARE FEET AND JOINT SPACING DOES NOT EXCEED 15'-0" ON
CENTER IN ANY ONE DIRECTION.
2. THE RATIO OF LENGTH TO WIDTH OF THE AREA BOUNDED BY CONTROL JOINTS SHALL NOT EXCEED 1.5 TO 1.
3. LOCATE CONSTRUCTION JOINTS AND OR CONTROL JOINTS AT COLUMN CENTERLINES.
4. LOCATE CONSTRUCTION JOINTS AND OR CONTROL JOINTS AT RE-ENTRANT CORNERS.
5. LOCATE CONSTRUCTION JOINTS PER "PLAN DETAIL AT INTERIOR DOORS".
6. PROVIDE DIAMOND OR CIRCULAR BLOCKOUTS AT COLUMNS.
7. REINFORCE ALL RE-ENTRANT CORNERS OF SLAB PER "SLAB REINFORCING AT RE-ENTRANT CORNERS".
8. PROVIDE BOND BREAK WHERE FLOOR ABUTS CMU OR CONCRETE WALL UNLESS NOTED OTHERWISE.
9. CONTROL JOINT NOT REQUIRED IF DIMENSION AT RE-ENTRANT CORNER IS 2'-0" OR LESS. PROVIDE
REINFORCING PER "SLAB REINFORCING AT RE-ENTRANT CORNER".
10. CONTROL JOINT / CONSTRUCTION JOINT PLANS SHALL BE SUBMITTED IF NOT SHOWN ON FOUNDATION PLANS.
3/4" CHAMFER
EDGE OF EQUIPMENT
#5 @ 16" OC EW
AT MID-DEPTH
NOTE: REFER TO MECH, ELEC, PLUMBING AND CIVIL
DRAWINGS FOR EQUIPMENT REQUIRING EXTERIOR PAD
NOTE: IF L OR W EXCEEDS 8'-0",THEN
t = 8"; OTHERWISE t = 6"
L OR W (NOTE)
8" 1' - 0"
6" t
EXTERIOR EQUIPMENT PAD
#4 @ 12" OC EW
AT MID-DEPTH
EDGE OF
EQUIPMENT
SLAB ON GRADE
3/4" CHAMFER
NOTE: REFER TO MECH, ELEC, PLUMBING AND CIVIL DRAWINGS
FOR EQUIPMENT REQUIRING HOUSEKEEPING PAD
6"
HOUSEKEEPING PAD
ROUGHEN
SURFACE
C
AO
M
M O N
W E
A LTH OF
V
I R G I N I
P
O
R O F
E
SS I
N
N
AL ENG
I
R E E
M O S E L E Y A R C H
IT
E C T S .C O M
JEFFREY S. O'BEIRNE
Lic. No. 036947
PROJECT NO:
DATE:
N
O R
F O
L K
S T
R E
E T
R
IC
H
M O
N D
V
A
P H
O N
E
-7
X
-5
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
/2
/2
:3
:1
P M
TYPICAL SLAB
DETAILS
H . R
. T . J
R . A
R N
G R
EA
D
IN
ES
S C
EN
TE
R (T
A R
C ) V
IS
IT
O R
S C
EN
TE
R
S . G
E O
R G
E M
A S
O N
D R
A
R L
IN
G
T O
N
V A
S3.0.2
V A
F M
P N
-0
594303
MAY 27 2020
NO SCALE
SLAB REINFORCING AT RE-ENTRANT CORNER
NO SCALE
SLAB ON GRADE DETAILS AT EXTERIOR DOORS
NO SCALE
DETAIL AT SLAB DEPRESSION
NO SCALE
SLAB-ON-GRADE JOINT DETAILS
NO SCALE
SLAB-ON-GRADE JOINT LAYOUT GUIDELINES
NO SCALE
EQUIPMENT PAD DETAILS
FIN FLOOR
BOND BREAK
8" CMU
REFER TO FDN PLAN
FOR VERT REINF
EIFS
REFER TO ARCH DWGS
FIN GRADE
REFER TO CIVIL DWGS
(+0'-8"), (+1'-4"), (+2'-0")
REFER TO ARCH DWGS
FOR CAVITY CONSTR
(REFER TO FDN PLAN NOTE 5)
REFER TO "WALL FOOTING
DETAIL" ON DWG S3.0.1
TOP OF FTG
REFER TO FDN PLAN
REFER TO FDN PLAN
1' - 1 1/8"
4" SOLID CMU
MORTAR COLLAR
JOINT SOLID
GROUT CMU SOLID
BELOW FIN FLOOR
DOWELS SHALL MATCH
WALL REINF
(M A
X C
A V
IT
Y
4" GROUND FACE CMU
REFER TO ARCH DWGS
BASE BIDADDITIVE BID ITEM #1
FIN FLOOR
BOND BREAK
8" CMU
REFER TO FDN PLAN
FOR VERT REINF
GROUT CMU SOLID
BELOW FIN FLOOR
DOWELS SHALL MATCH
WALL REINF
EIFS
REFER TO ARCH DWGS
GARDEN SOIL
REFER TO CIVIL DWGS
(+0'-8")
4" SOLID CMU
4" GROUND FACE CMU
REFER TO ARCH DWGS
REFER TO ARCH DWGS
FOR CAVITY CONSTR
1' - 1 1/8"
REFER TO "WALL FOOTING
DETAIL" ON DWG S3.0.1
TOP OF FTG
REFER TO FDN PLAN
REFER TO FDN PLAN
MORTAR COLLAR
JOINT SOLID
(M A
X C
A V
IT
Y
FIN FLOOR
BOND BREAK
8" CMU
REFER TO FDN PLAN
FOR VERT REINF
GROUT CMU SOLID
BELOW FIN FLOOR (TYP)
DOWELS SHALL MATCH
WALL REINF
GARDEN SOIL
REFER TO CIVIL DWGS
6" CMU
MANUFACTURED STONE
REFER TO ARCH DWGS
REFER TO ARCH DWGS
FOR CAVITY CONSTR
REFER TO "WALL FOOTING
DETAIL" ON DWG S3.0.1
TOP OF FTG
REFER TO FDN PLAN
MORTAR COLLAR
JOINT SOLID
(M A
X C
A V
IT
Y
EIFS
REFER TO ARCH DWGS
PRECAST WATERTABLE
REFER TO ARCH DWGS
(+3'-4")
(+0'-8")
1' - 3 3/4"
6" GROUND FACE CMU
GROUTED SOLID
REFER TO ARCH DWGS
REFER TO FDN PLAN
4" CMU
SITE SLAB
REFER TO CIVIL DWGS
FIN FLOOR
BOND BREAK
8" CMU
REFER TO FDN PLAN
FOR VERT REINF
EIFS
REFER TO ARCH DWGS
(+0'-8")
REFER TO "WALL FOOTING
DETAIL" ON DWG S3.0.1
TOP OF FTG
REFER TO FDN PLAN
REFER TO FDN PLAN
1' - 1 1/8"
4" SOLID CMU
MORTAR COLLAR
JOINT SOLID
GROUT CMU SOLID
BELOW FIN FLOOR
DOWELS SHALL MATCH
WALL REINF
REFER TO ARCH DWGS
FOR CAVITY CONSTR
(M A
X C
A V
IT
Y
4" GROUND FACE CMU
REFER TO ARCH DWGS
BASE BIDADDITIVE BID ITEM #1
REFER TO "WALL FOOTING
DETAIL" ON DWG S3.0.1
GROUT CMU SOLID
BELOW GRADE
REFER TO FDN PLAN
4" SOLID CMU
GARDEN SOIL
REFER TO CIVIL DWGS
MORTAR COLLAR
JOINT SOLID
1' - 3 5/8"
TOP OF FTG
REFER TO FDN PLAN
8" CMU
REFER TO FDN PLAN
FOR VERT REINF
DOWELS SHALL MATCH
WALL REINF
EIFS
REFER TO ARCH DWGS
FIN GRADE
REFER TO CIVIL DWGS
(+0'-8")
4" GROUND FACE CMU
REFER TO ARCH DWGS
4" SOLID CMU
EIFS
REFER TO ARCH DWGS
MORTAR COLLAR
JOINT SOLID
4" GROUND FACE CMU
REFER TO ARCH DWGS
REFER TO "WALL FOOTING
DETAIL" ON DWG S3.0.1
10" CMU
GROUTED SOLID
REFER TO FDN PLAN
MANUFACTURED STONE
REFER TO ARCH DWGS
GARDEN SOIL
REFER TO CIVIL DWGS
MORTAR COLLAR
JOINT SOLID
(+3'-4")
TOP OF FTG
REFER TO FDN PLAN
8" CMU
REFER TO FDN PLAN
FOR VERT REINF
DOWELS SHALL MATCH
WALL REINF
EIFS
REFER TO ARCH DWGS
FIN GRADE
REFER TO CIVIL DWGS
(+0'-8")
4" GROUND FACE CMU
REFER TO ARCH DWGS
4" SOLID CMU
10" GROUND FACE CMU
GROUTED SOLID
REFER TO ARCH DWGS
1' - 1 5/8"
PRECAST WATERTABLE
REFER TO ARCH DWGS;
CONN TO CMU AS REQ'D
BY PRECAST MFR
GROUT COURSE SOLID
REFER TO FDN PLAN
REFER TO "WALL FOOTING
DETAIL" ON DWG S3.0.1
8" CMU
REFER TO FDN PLAN
FOR VERT REINF
6" CMU
GROUTED SOLID
GARDEN SOIL
REFER TO CIVIL DWGS
EIFS
REFER TO ARCH DWGS
4" SOLID CMU
TOP OF FTG
REFER TO FDN PLAN
DOWELS SHALL MATCH
WALL REINF
EIFS
REFER TO ARCH DWGS
FIN GRADE
REFER TO CIVIL DWGS
MANUFACTURED STONE
REFER TO ARCH DWGS
4" SOLID CMU
MORTAR COLLAR
JOINT SOLID
MANUFACTURED STONE
REFER TO ARCH DWGS
PRECAST WATERTABLE
REFER TO ARCH DWGS;
CONN TO CMU AS REQ'D
BY PRECAST MFR
(TYP EA SIDE)GROUT COURSE SOLID
(+3'-4")
BASE BIDADDITIVE BID ITEM #1
REFER TO FDN PLAN
REFER TO "WALL FOOTING
DETAIL" ON DWG S3.0.1
8" CMU
REFER TO FDN PLAN
FOR VERT REINF
GROUT CMU SOLID
BELOW GRADE
GARDEN SOIL
REFER TO CIVIL DWGS
EIFS
REFER TO ARCH DWGS
4" SOLID CMU
TOP OF FTG
REFER TO FDN PLAN
DOWELS SHALL MATCH
WALL REINF
EIFS
REFER TO ARCH DWGS
FIN GRADE
REFER TO CIVIL DWGS
4" SOLID CMU
MORTAR COLLAR
JOINT SOLID
1' - 3 5/8"
(+0'-8")
4" GROUND FACE CMU
REFER TO ARCH DWGS
4" GROUND FACE CMU
REFER TO ARCH DWGS
MORTAR COLLAR
JOINT SOLID
(+0'-8") 4" GROUND FACE CMU
REFER TO ARCH DWGS
1' - 1 5/8"
4" GROUND FACE CMU
REFER TO ARCH DWGS
8" CMU
REFER TO FDN PLAN
FOR VERT REINF
JBE (+11'-4")
8x16 OPEN BOT BOND
BEAM W/ (2) #5 CONT
REINF INDICATED BROKEN
FOR CLARITY
JOIST
REFER TO PLAN
1 1/2" STEEL
ROOF DECK
DOWN
3/16
CONT L3x3x1/4
REFER TO FRAMING PLAN
FOR SEAT HEIGHT
(+15'-4")
8x8 OPEN BOT BOND
BEAM W/ (2) #5 CONT
EIFS
REFER TO ARCH DWGS
8" CMU
REFER TO FDN PLAN
FOR VERT REINF
EIFS
REFER TO ARCH DWGS
GROUT CMU SOLID
AT ANCHORS
JOIST
REFER TO PLAN
1 1/2" STEEL
ROOF DECK
3/16 3-12
CONT L4x4x5/16 W/ 5/8"
DIAM SCREW ANCHORS
@ 2'-8" OC
4"
(VARIES)
(+15'-4")
8x8 OPEN BOT BOND
BEAM W/ (2) #5 CONT
EIFS
REFER TO ARCH DWGS
DOWN
8x8 OPEN BOT BOND
BEAM W/ (2) #5 CONT
8x16 OPEN BOT BOND
BEAM W/ (2) #5 CONT
REINF INDICATED BROKEN
FOR CLARITY
1 1/2" STEEL
ROOF DECK
3/16
CONT L3x3x1/4
JBE (+13'-0")
REFER TO FRAMING PLAN
FOR SEAT HEIGHT
JOIST
REFER TO PLAN
(+15'-4")
8" CMU
REFER TO FDN PLAN
FOR VERT REINF
8" CMU
REFER TO FDN PLAN
FOR VERT REINF
EIFS
REFER TO ARCH DWGS
(+15'-4")
8x16 OPEN BOT BOND
BEAM W/ (2) #5 CONT
JOIST
REFER TO PLAN
1 1/2" STEEL
ROOF DECK
DOWN
3/16
CONT L3x3x1/4
8x8 OPEN BOT BOND
BEAM W/ (2) #5 CONT
JBE (+12'-4")
REINF INDICATED BROKEN
FOR CLARITY
REFER TO FRAMING PLAN
FOR SEAT HEIGHT
8" CMU
REFER TO FDN PLAN
FOR VERT REINF
EIFS
REFER TO ARCH DWGS
(+9'-4")
8x24 OPEN BOT BOND
BEAM W/ (2) #5 CONT
EA COURSE
EIFS
REFER TO ARCH DWGS
8" CMU
REFER TO FDN PLAN
FOR VERT REINF
EIFS
REFER TO ARCH DWGS
JOIST
REFER TO PLAN
1 1/2" STEEL
ROOF DECK
3/16 3-12
CONT L4x4x5/16 W/ 5/8"
DIAM SCREW ANCHORS
@ 2'-8" OC
4"
GROUT CMU SOLID
AT ANCHORS
(VARIES)
ARCH PRECAST BEARING
CONN TO CMU PILASTER
BEYOND BY PRECAST MFR
(SELF-SUPPORTING ONLY)
CONT 5"x1/4" BRG PLATE W/ 1/2" DIAM x 6" HEADED
STUDS @ 2'-8" OC
(TYP OF 2)
8x24 OPEN BOT BOND
BEAM W/ (2) #5 CONT
EA COURSE
1 1/2" STEEL
ROOF DECK
MORTAR COLLAR
JOINT SOLID
(+12'-0")
(+16'-0")
8x8 OPEN BOT BOND
BEAM W/ (2) #5 CONT
MANUFACTURED STONE
REFER TO ARCH DWGS
8x24 OPEN BOT BOND
BEAM W/ (2) #5 CONT
EA COURSE
GROUT CUT COURSE
CMU SOLID
8" CMU
REFER TO FDN PLAN
FOR VERT REINF
EIFS
REFER TO ARCH DWGS
EIFS
REFER TO ARCH DWGS
1 1/2" STEEL
ROOF DECK
CONT 5"x1/4" BRG PLATE W/ 1/2" DIAM x 6" HEADED
STUDS @ 2'-8" OC
(TYP OF 2)
8x24 OPEN BOT BOND
BEAM W/ (2) #5 CONT
EA COURSE
(+12'-0")
(+16'-0")
8x8 OPEN BOT BOND
BEAM W/ (2) #5 CONT
ARCH PRECAST BEARING
CONN TO CMU PILASTER
BEYOND BY PRECAST MFR
(SELF-SUPPORTING ONLY)
MORTAR COLLAR
JOINT SOLID
MANUFACTURED STONE
REFER TO ARCH DWGS
8x24 OPEN BOT BOND
BEAM W/ (2) #5 CONT
EA COURSE
GROUT CUT COURSE
CMU SOLID
1 1/2" STEEL
ROOF DECK
BEAM
REFER TO PLAN
(+11'-0")
2' - 2" 2"
CONT L3x3x1/4
HSS2-1/2x2-1/2x1/4
OUTLOOKER
3/16
3 SIDES
3/16
362S162-43 STUDS (MIN)
@ 16" OC (TYP EA SIDE)
362S162-43 STUDS (MIN)
@ 16" OC; CLIP TO
BEAM FLANGE (TYP)
(3) 362S162-43 STUDS (MIN)
BTWN OUTLOOKERS W/
14 GA CLIP ANGLE EA END
CONT L3x2x1/4
(LLV, EA SIDE)
14GA CLIP ANGLE (TYP)
BEAM
REFER TO PLAN
CONT 362T125-43 TRACK
(TYP EA SIDE)
CONT BOX BEAM W/ (2)
362S162-43 STUDS (MIN)
W/ TOP & BOT TRACK
3/16 3-12
TYP
600S162-43 STUDS (MIN)
@ 16" OC; PROVIDE CONT
600T125-43 TRACK
(TOP & BOT)
PROVIDE (2) 3-5/8" STUDS
BELOW 6" STUDS FOR
SUPPORT; CONN STUDS
TO BOT TRACK
(+11'-0")
1 1/2" STEEL
ROOF DECK
3/16 3-12
BEAM
REFER TO PLAN
CONT L6x4x5/16 (LLH)
362S162-43 STUDS (MIN)
@ 16" OC
362S162-43 STUDS (MIN)
@ 16" OC (TYP EA SIDE)
CONT L3x2x1/4 (LLV)
600S162-43 STUDS (MIN)
@ 16" OC, MATCH ADJ
STUDS; PROVIDE CONT
600T125-43 TRACK
(TOP & BOT)
362S162-43 STUDS (MIN)
@ 16" OC
14GA CLIP ANGLE (TYP)
3/16 3-12
1' - 0 3/8"
CONT 14 GA ANGLE W/ 5"
LEGS; CONN TO TRACK
AND EA STUD W/ (2) #10-16
SELF-DRILLING SCREWS
PROVIDE CONT 362T125-43
TOP TRACK; CONN TO L6x4
8" CMU
REFER TO FDN PLAN
FOR VERT REINF
EIFS
REFER TO ARCH DWGS
BEAM
REFER TO PLAN
9 1/8"
(+11'-0")
(+15'-4")
8x8 OPEN BOT BOND
BEAM W/ (2) #5 CONT
8x16 OPEN BOT BOND
BEAM W/ (2) #5 CONT
REINF INDICATED BROKEN
FOR CLARITY
JOIST
REFER TO PLAN
1 1/2" STEEL
ROOF DECK
3/16
CONT L3x3x1/4
JBE (+13'-0")
REFER TO FRAMING PLAN
FOR SEAT HEIGHT
1 1/2" STEEL
ROOF DECK
DOWN
CONT 1/4" BENT PLATE
3/16 3-12
362S162-43 STUDS (MIN)
@ 16" OC; CLIP TO
BEAM FLANGE (TYP)
BEAM
REFER TO PLAN
7"
7"
3"
(+11'-0")
W12 COL
4" GROUND FACE CMU
REFER TO ARCH DWGS
EIFS
REFER TO ARCH DWGS
BEAM
REFER TO PLAN
(+8'-0")
1 1/2" STEEL
ROOF DECK
BEAM
REFER TO PLAN
PROVIDE HSS2-1/2x2-1/2x1/4
FOR DECK SUPPORT
AROUND COL WRAP
(TYP 3 SIDES)
3/16
1 1/2" STEEL
ROOF DECK
400S162-54 STUDS
(TYP AROUND COL)
(+12'-4")
(+11'-0")
2' - 2" 2"
1 1/2" STEEL
ROOF DECK
3/16
3 SIDES
BEAM
REFER TO PLAN
CONT BOX BEAM W/ (2)
362S162-43 STUDS (MIN)
W/ TOP & BOT TRACK
362S162-43 STUDS (MIN)
@ 16" OC (TYP EA SIDE)
CONT 362T125-43 TRACK
(TYP EA SIDE)
362S162-43 STUDS (MIN)
@ 16" OC; CLIP TO
BEAM WEB (TYP)
BEAM
REFER TO PLAN
3/16 3-12
TYP
CONT L3x2x1/4
(LLV, EA SIDE)
HSS2-1/2x2-1/2x1/4
OUTLOOKER
(3) 362S162-43 STUDS (MIN)
BTWN OUTLOOKERS W/
14 GA CLIP ANGLE EA END
14GA CLIP ANGLE (TYP)
CONT L3x3x1/4
3/16
600S162-43 STUDS (MIN)
@ 16" OC; PROVIDE CONT
600T125-43 TRACK
(TOP & BOT)
PROVIDE (2) 3-5/8" STUDS
BELOW 6" STUDS FOR
SUPPORT; CONN STUDS
TO BOT TRACK
(+11'-0")
1 1/2" STEEL
ROOF DECK
BEAM
REFER TO PLAN
BEAM
REFER TO PLAN
HSS2-1/2x2-1/2x1/4
OUTLOOKER
(3) 362S162-43 STUDS (MIN)
BTWN OUTLOOKERS W/
14 GA CLIP ANGLE EA END
362S162-43 STUDS (MIN)
@ 16" OC; CLIP TO
BEAM FLANGE (TYP)
EIFS
REFER TO ARCH DWGS
(+8'-0")
4" GROUND FACE CMU
REFER TO ARCH DWGS
CONT L3x3x1/4
3/16
600S162-43 STUDS (MIN)
@ 16" OC; PROVIDE CONT
600T125-43 TRACK
(TOP & BOT)
PROVIDE (2) 3-5/8" STUDS
BELOW 6" STUDS FOR
SUPPORT; CONN STUDS
TO BOT TRACK
W12 COL
1 1/2" STEEL
ROOF DECK
400S162-54 STUDS
(TYP AROUND COL)
(+12'-4")
(+11'-0")
1 1/2" STEEL
ROOF DECK
BEAM
REFER TO PLAN
362S162-43 STUDS (MIN)
@ 16" OC (EA SIDE)
CONT 600S162-43 STUD
W/ 600T125-43 TRACK
(TYP EA SIDE)
14GA CLIP ANGLE
(TYP TOP & BOT)
C
AO
M
M O N
W E
A LTH OF
V
I R G I N I
P
O
R O F
E
SS I
N
N
AL ENG
I
R E E
M O S E L E Y A R C H
IT
E C T S .C O M
JEFFREY S. O'BEIRNE
Lic. No. 036947
PROJECT NO:
DATE:
N
O R
F O
L K
S T
R E
E T
R
IC
H
M O
N D
V
A
P H
O N
E
-7
X
-5
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
/2
/2
:3
:1
P M
FOUNDATION
AND FRAMING
SECTIONS
H . R
. T . J
R . A
R N
G R
EA
D
IN
ES
S C
EN
TE
R (T
A R
C ) V
IS
IT
O R
S C
EN
TE
R
S . G
E O
R G
E M
A S
O N
D R
A
R L
IN
G
T O
N
V A
S3.1
V A
F M
P N
-0
594303
MAY 27 2020
3/4" = 1'-0"S1.1 S3.1
SECTION4
3/4" = 1'-0"S1.1 S3.1
SECTION1
3/4" = 1'-0"S1.1 S3.1
SECTION5
3/4" = 1'-0"S1.1 S3.1
SECTION3
3/4" = 1'-0"S1.1 S3.1
SECTION2
3/4" = 1'-0"S1.1 S3.1
SECTION6
3/4" = 1'-0"S1.1 S3.1
SECTION7
3/4" = 1'-0"S1.1 S3.1
SECTION8
3/4" = 1'-0"S1.1 S3.1
SECTION9
3/4" = 1'-0"S1.1 S3.1
SECTION10
3/4" = 1'-0"S1.1 S3.1
SECTION11
3/4" = 1'-0"S1.1 S3.1
SECTION12
3/4" = 1'-0"S1.1 S3.1
SECTION13
3/4" = 1'-0"S1.1 S3.1
SECTION16
3/4" = 1'-0"S1.1 S3.1
SECTION15
3/4" = 1'-0"S1.1 S3.1
SECTION17
3/4" = 1'-0"S1.1 S3.1
SECTION14
3/4" = 1'-0"S1.1 S3.1
SECTION18
3/4" = 1'-0"S1.1 S3.1
SECTION19
TOP OF FOOTING
ELEVATION (+11'-0")
ELEVATION (+8'-0")
4" CMU VENEER
5/8" STRUCTURAL SHEATHING (TYP)
(10) 400S162-54 STUDS
CONN INTERIOR STUDS
TO COL FLANGE W/ TIE
PLATES @ 4'-0" OC
(TYP OF 4)
EIFS
REFER TO ARCH DWGS
W12 COL
TOP OF CMU (+8'-0")
8" 1' - 0" 1' - 4"
BREAK STUD ABOVE
AND BELOW CANOPY
BEAM AS REQ'D
OUTLOOKER
REFER TO PLAN
5/8" STRUCTURAL SHEATHING (TYP)
(10) 400S162-54 STUDS
CONN INTERIOR STUDS
TO COL FLANGE W/ TIE
PLATES @ 4'-0" OC
(TYP OF 4)
EIFS
REFER TO ARCH DWGS
W12 COL
CMU BELOW (+8'-0")
CANOPY BEAM
REFER TO PLAN
CANOPY BEAM
REFER TO PLAN
PROVIDE TOP 400T125-43
TRACK CONT AROUND
PERIMETER OF STUDS
AT (+12'-6")
REFER TO 17/S3.1 FOR
HSS DECK SUPPORT
NOT INDICATED
(TYP 3 SIDES)
CONC FOOTING
W12 COL W/ BASE PLATE
REFER TO FDN PLAN
COL & FOOTING CL
4" SOLID CMU (FTG TO +0'-0")
COL & FOOTING CL
5/8" STRUCTURAL SHEATHING (TYP)
(10) 400S162-54 STUDS;
BOT (+0'-0")
CONN INTERIOR STUDS
TO COL FLANGE W/ TIE
PLATES @ 4'-0" OC
(TYP OF 4)
2' - 3" 2' - 3"
PROVIDE CONT 400T125-43
TRACK AT STUD BOT (+0'-0");
CONN TO SOLID CMU
(TYP 4 SIDES)
/4
(S T
U D
/4
(S T
U D
1' - 6" 1' - 6"
MORTAR COLLAR
JOINT SOLID
(TYP 4 SIDES)
/8
/8
JT
/8
/4
/8
/8
JT
/8
3 5/8"
1 3/8" JT
3 5/8" 1' - 6 3/4" 3 5/8"
1 3/8" JT
3 5/8"
(STUD)
4 3/4"
(STUD)
4 3/4"
NOTE: PROVIDE CMU BLOCKOUT AT FIRST COURSE ON TOP OF FOOTING FOR RAIN LEADER TURN-OUT.
RAIN LEADER AT COLUMN C1 ONLY.
NOTE
RAIN LEADER
COL C1 ONLY
RAIN LEADER
COL C1 ONLY
ELEVATION (+8'-0")
EIFS
REFER TO ARCH DWGS
8" CMU
4" CMU VENEER
5/8" STRUCTURAL SHEATHING (TYP)
(10) 400S162-54 STUDS
CONN INTERIOR STUDS
TO COL FLANGE W/ TIE
PLATES @ 4'-0" OC
(TYP OF 4)
EIFS
REFER TO ARCH DWGS
W12 COL
TOP OF CMU (+8'-0")
/8
4" CMU VENEER
TOP OF CMU (+8'-0")
BREAK STUD ABOVE
AND BELOW CANOPY
BEAM AS REQ'D
(TYP OF 3)
CONN INTERIOR STUDS
TO COL FLANGE W/ TIE
PLATES @ 4'-0" OC; TOP
TIE PLATE SHALL BE AT
TOP OF COL (TYP OF 4)
PROVIDE TOP 400T125-43
TRACK CONT AROUND
PERIMETER OF STUDS
AT (+12'-6")
EIFS
REFER TO ARCH DWGS
5/8" STRUCTURAL SHEATHING (TYP)
W12 COL BELOW
CANT BEAM
CANOPY BEAM
REFER TO PLAN
(10) 400S162-54 STUDS
EIFS
REFER TO ARCH DWGS
8" CMU
ELEVATION (+11'-0")
DECK SUPPORT
ANGLE FRAMING
REFER TO PLAN
CMU BELOW (+8'-0")
CANOPY BEAM
REFER TO PLAN
CMU BELOW (+8'-0")
TOP OF FOOTING
/8
/8
/8
COL & FOOTING CL
W12 COL W/ BASE PLATE
REFER TO FDN PLAN
COL & FOOTING CL
8" CMU
GROUNTED SOLID
4" SOLID CMU
5/8" STRUCTURAL SHEATHING (TYP)
(10) 400S162-54 STUDS;
BOT (+0'-0")
1' - 0" 1' - 0"
CONC FOOTING
4" SOLID CMU (FTG TO +0'-0")
(TYP 3 SIDES)
CONN INTERIOR STUDS
TO COL FLANGE W/ TIE
PLATES @ 4'-0" OC
(TYP OF 4)
PROVIDE CONT 400T125-43
TRACK AT STUD BOT (+0'-0");
CONN TO SOLID CMU
(TYP 4 SIDES)
7 1/4" (STUD) 7 1/4" (STUD)
4" SOLID CMU
MORTAR COLLAR
JOINT SOLID
(TYP 3 SIDES)
3 5/8"
1 3/8" JT
3 5/8" 6 3/4" 3 5/8"
1 3/8" JT
3 5/8"
(S T U D
/4
/8
/8
JT
/8
NOTE: PROVIDE CMU BLOCKOUT AT FIRST COURSE ON TOP OF FOOTING FOR RAIN LEADER TURN-OUT.
NOTE
RAIN LEADER
RAIN LEADER
/8
1 3/8"
NOTES: 1. ADDITIVE BID ITEM #1 INDICATED IN PLAN DETAILING.
2. GROUT 10" CMU PILASTER SOLID AND REINFORCE WITH #5 @ 8" OC VERTICAL BARS.
3. REFER TO ARCH DRAWINGS FOR MANUFACTURED STONE ABOVE SOLID FDN CMU.
10" CMU
GROUTED SOLID
4" SOLID CMU
6" CMU
GROUTED SOLID
/1
/8
/4
/8
9 3/16" 1' - 2" 1' - 1 5/8" (ADD BID ITEM #1)
9 5/8" 8 3/8" 9 5/8"
MORTAR COLLAR
JT SOLID
10" CMU
GROUTED SOLID
/4
(A D
D B
ID
/8
(A D
D B
ID
I T
E M
MORTAR COLLAR
JT SOLID
4" SOLID CMU
4" SOLID CMU
10" CMU
GROUTED SOLID
10" CMU
GROUTED SOLID
/4
(B
A S
E B
ID
/8
(B A
S E
B
ID
1' - 3 5/8" (BASE BID)
/8
/4
/8
9 3/16" 1' - 2" 1' - 1 5/8" (ADD BID ITEM #1) 1' - 11 3/16"
9 5/8" 8 3/8" 9 5/8"
10" CMU
GROUTED SOLID
MORTAR COLLAR
JT SOLID
10" CMU
GROUTED SOLID
4" SOLID CMU
4" SOLID CMU
MORTAR COLLAR
JT SOLID
1' - 2" 1' - 1 5/8"
10" CMU
GROUTED SOLID
1…