This federal solicitation is for the construction of a Visitor's Center building at the Herbert R. Temple Jr. Army National Guard Readiness Center in Arlington, Virginia. Work will involve civil, architectural, security, structural, plumbing, mechanical, and electrical disciplines. The estimated value is between $1 million to $5 million. The period of performance is 425 calendar days from notice to proceed. The primary NAICS code is 236220 for commercial and institutional building construction. The solicitation includes specifications and drawings for the project.
View the file
Other files
Show all 28
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONSTRUCTION GRADE
4" 3' - 4" 4"
6" 3' - 0" 6"
4' - 0"
PROJECT NAME & OWNER, ETC. - REFER
TO "TEXT LAYOUT ELEVATION"
THIS DRAWING
3/4" MDO PLYWOOD - SECURE TO POSTS W/
8 CARRIAGE BOLTS LOCATED AS INDICATED
(+). PAINT HEADS TO MATCH SIGN
BACKGROUND COLOR
REFER TO "ARCHITECT'S SIGN" THIS
DRAWING
CONTRACTOR'S SIGN - 3'-4"W X 1'-7"H W/ 2"
RADIUS CORNERS. APPLIED PANEL OR
DIRECT PAINTED AT CONTRACTOR'S
OPTION
4x4 PPT - POSTS
CUT TOPS THUS
6" RADIUS (TYPICAL)
NOTE;
BACKGROUND SIGN, POSTS, & FASTENERS
SHALL RECEIVE 2 COATS EXTERIOR ENAMEL
ROLL-APPLIED PAINT (BACK SIDE OF SIGN 1
COAT ONLY), IN COLOR WHITE.
45°
1" FLAT
H.R.T. JR. ARNG
READINESS
CTR VISITOR'S
CENTER4
REFER TO
"ARCHITECT'S SIGN"
THIS DRAWING
GENERAL NOTE:
SIGN BACKGROUND SHALL BE PAINTED WHITE. TEXT
SHALL BE PAINTED TO MATCH PANTONE 432 (GRAY).
A. THE CONTRACT DOCUMENTS ARE COMPLEMENTARY AND WHAT IS REQUIRED BY
ONE SHALL BE AS BINDING AS IF REQUIRED BY ALL. IN THE CASE OF A CONFLICT,
DISAGREEMENT, OR AMBIGUITY, PROVIDE THE BETTER QUALITY. IN THE CASE OF A
CONFLICT, DISAGREEMENT, OR AMBIGUITY, PROVIDE THE GREATER QUANTITY OF
WORK.
B. ELEMENTS THAT ARE IDENTIFIED BY OTHER DISCIPLINES (e.g., CIVIL, STRUCTURAL, PLUMBING, FIRE PROTECTION, MECHANICAL, ELECTRICAL) ELSEWHERE WITHIN THE
ARCHITECTURAL SERIES OF DRAWINGS AND/OR SPECIFICATIONS, OR IDENTIFIED OR
COVERED BY DEFAULTS (e.g., SIZES, THICKNESS, SPACING, MATERIALS) IN THE
SPECIFICATIONS MAY NOT BE ANNOTATED (NOTE OR KEYNOTED) ON THESE
DRAWINGS.
C. ELEMENTS IDENTIFIED IN "LEGENDS" AND/OR "GENERAL NOTES" MAY NOT BE NOTED
IN DETAILS, OR SECTIONS, AS THESE ELEMENTS ARE IDENTIFIED IN THE LEGENDS
(e.g. FACE BRICK, CMU, WINDOWS)
D. REFER TO "ASSEMBLIES" FOR MATERIALS AND COMPONENTS THAT MAKE UP THAT
PARTICULAR ASSEMBLY (e.g., EXTERIOR WALL ASSEMBLIES, ROOF ASSEMBLIES, AND
FIRE-RATED ASSEMBLIES). ONCE A PARTICULAR ASSEMBLY HAS BEEN IDENTIFIED
ON ONE DRAWING, THAT SAME ASSEMBLY GRAPHIC SHALL APPLY TO ALL OTHER
SIMILAR LOCATIONS UNLESS SPECIFICALLY INDICATED OTHERWISE. PROVIDE THAT
SAME ASSEMBLY AT THE SIMILAR LOCATION WHETHER THE ASSEMBLY GRAPHIC
SYMBOL IS SHOWN OR NOT.
E. VERIFY ALL DIMENSIONS, INCLUDING DIMENSIONS ON STRUCTURAL DRAWINGS AND
OTHER ARCHITECTURAL DRAWINGS. IMMEDIATELY NOTIFY ARCHITECT OF ANY
DISCREPANCIES.
F. PROVIDE CONCRETE HOUSEKEEPING PADS FOR ALL EQUIPMENT INDICATED TO BE
MOUNTED OR OTHERWISE REQUIRED TO BE MOUNTED TO THE FLOOR. WHERE
PADS ARE NOT SHOWN, PROVIDE 6" THICK CONCRETE PADS W/ 3/4" CHAMFERED
EDGES (ALL SIDES). REINFORCE WITH MESH EQUIVALENT TO FLOOR SLAB
REINFORCING REQUIREMENTS.
ARCHITECTURAL GENERAL NOTES
N
KEYNOTES
ENLARGED PLAN OR WALL SECTION TITLE
1/4"=1'-0"
A7.1
ENLARGED PLAN OR WALL SECTION NUMBER
DRAWING NUMBER WHERE ENLARGED PLAN OR WALL SECTION IS INDICATED
DRAWING NUMBER WHERE ENLARGED PLAN OR WALL SECTION IS CUT
ADDITIONAL DRAWING NUMBERS WHERE ENLARGED PLAN OR WALL
SECTION IS CUT
A2.1 A2.3 A2.6
ARCHITECTURAL GRAPHIC SYMBOL LEGEND
1. KEYNOTES ARE GENERALLY ASSOCIATED WITH A SERIES OF DRAWINGS (e.g., A3.2.n, A5.1.n); THEREFORE KEYNOTE NUMBERS FROM SERIES TO SERIES WILL VARY (i.e., KEYNOTE NO. 1 IN THE A3.2.n SERIES WILL BE DIFFERENT FROM KEYNOTE NO. 1 IN THE A5.1.n SERIES).
n nnn n n/n"
KEYNOTE (1 TO 2 DIGITS)
KEYNOTE (3 DIGITS ONLY)
SIZE; THICKNESS; OR OTHER
DESCRIPTIVE INFORMATION
REFER TO
A3.0.1 FOR
FINISH
SCHEDULE
REFER TO
A3.1.1 FOR
SCHEDULE
SPACE NAME
SPACE NUMBER
SQUARE FOOTAGE, IF INDICATED
BUILDING "PART" NUMBER
IN MULTI-PART BUILDING
SUPERVISOR'S
OFFICE
100 SF
A101
SPACE
DOOR
FIRE RATING IN MINUTES (IF INDICATED)
DOOR SUFFIX LETTER WHEN MORE
THAN ONE DOOR PER SPACE
SPACE NUMBER
A101C
STL
AW
AS
CW
LVR
GBLK
STEEL FRAME NUMBER
ALUMINUM WINDOW NUMBER
ALUMINUM STOREFRONT NUMBER
CURTAIN WALL NUMBER
LOUVER NUMBER
GLASS BLOCK NUMBER
JOINT
ELEVATION OR BUILDING SECTION TITLE
1/4"=1'-0"
A A4.1
ELEVATION OR BUILDING SECTION LETTER
DRAWING NUMBER WHERE ELEVATION OR BUILDING SECTION IS INDICATED
DRAWING NUMBER WHERE ELEVATION OR BUILDING SECTION IS CUT
ADDITIONAL DRAWING NUMBERS WHERE ELEVATION OR BUILDING SECTION IS CUT
A2.0.1 A2.0.2 A2.0.3
PLAN TITLE
1/8"=1'-0"
DETAIL TITLE
1/2"=1'-0"
A5.2
DETAIL NUMBER OR LETTER
DRAWING NUMBER WHERE DETAIL IS INDICATED
DRAWING NUMBER WHERE DETAIL IS CUT
ADDITIONAL DRAWING NUMBERS WHERE DETAIL IS CUT
A5.1
A5.3 A5.7
A2.1
A2.1
A2.1
A2.1
A7.1
A7.1
2 4
WALL OR MISC SECTION WHERE CUT
WALL SECTION NUMBER
DRAWING NUMBER WHERE
WALL SECTION IS INDICATED
DETAIL OR ENLARGED PLAN WHERE CUT
DETAIL OR ENLARGED PLAN NUMBER
DRAWING NUMBER WHERE DETAIL
OR ENLARGED PLAN IS INDICATED
BUILDING SECTION WHERE CUT
INTERIOR OR EXTERIOR ELEVATION WHERE CUT
SECTION NUMBER
DRAWING NUMBER WHERE SECTION
IS INDICATED
ELEVATION NUMBER
DRAWING NUMBER WHERE ELEVATION IS INDICATED
MULTIPLE ELEVATIONS
1 CASEWORK TITLE
1/4"=1'-0"
CASEWORK ELEVATION NUMBER
REFER TO A3.1.n
FOR TYPES
REFER TO A3.1.n
FOR TYPES
REFER TO A3.1.n
FOR TYPES
REFER TO A3.1.n
FOR TYPES
REFER TO A3.1.n
FOR TYPES
REFER TO A3.1.n
FOR TYPES
REFER TO A0.2
FOR LEGEND
SURFACE MOUNT FEC: TOP OF CABINET AT 4'-0" AFF
FEC
1T EQUIPMENT TYPE
INTERIOR ARCHITECTURAL
WOODWORK (CASEWORK)
ELEVATION
ROOF ASSEMBLY
FIRE-RATED ASSEMBLY
WALL ASSEMBLY
GLAZING/GLASS TYPES
PLAN NORTH (MAY DIFFER
FROM POLAR NORTH)
RFAn
Xn
WAn n
A8.1A8.3
MATCH LINE
WORKING POINT
DATUM POINT
CENTERLINE
REFER TO
A8.1.1 FOR
ELEVATIONS
REFER TO A10.1
FOR LEGEND
REFER TO LS1.1
FOR LEGEND
REFER TO A5.1.1
FOR LEGEND
REFER TO A3.1.n
FOR LEGEND
TOILET ASSEMBLYTAn
REFER TO A7.1.1
FOR LEGEND
PLATE
WPT
CL
PL
REFER TO
A0.2 FOR
LEGEND SB=SMOKE BARRIER
SP=SMOKE PARTITION
IU=INCIDENTAL USEXn-XX
WALL PARTITION TYPE
FIRE RESISTANCE RATING
IN HOURSXn-n
WALL PARTITION TYPE
SEMI-RECESSED FEC: T.O. MASONRY OPENING AT 4'-0" AFF
FEC
FULLY-RECESSED FEC: T.O. MASONRY OPENING AT 4'-0" AFF
FEC
BRACKET: MOUNT BRACKET AT 4'-0" AFF
FEB
A
STRUCTURAL GRID LINE
WITH DESIGNATIONS
ARCHITECTURAL MATERIALS LEGEND
EARTH
POROUS FILL
CONCRETE
ACOUSTICAL BATTING
RIGID INSULATION
SPRAYED
POLYURETHANE
FOAM
WOOD SHIM
WOOD BLOCKING -
CONTINUOUS
FINISHED WOOD
PLYWOOD
GYPSUM BOARD /
SHEATHING
CONCRETE
MASONRY UNIT
GROUTED SOLID
CONCRETE
MASONRY UNIT
NOTE: PROVIDE 100% SOLID, PLANT-
CAST UNITS WHERE CORE HOLES
WOULD BE VISIBLE WITHIN FINISH
SPACE, AND WHERE A BLOCK ACTS
AS THE BASE FOR A BED OF
SEALANT.
ARCHITECTURAL
PRECAST CONCRETE
CAST STONE
MASONRY
NOTE: ALL VENEER CMU SHALL BE
GROUND FACE
/4
/2
/4
3 1/4" 3 1/4"
2" RADIUS
(TYPICAL)
SIZE: 1'-11" VERTICAL x 3'-4" HORIZONTAL
NOTES:
"MOSELEY" TEXT IN LOGO AND WEB ADDRESS IS PMS 485. BULLETS ARE PMS 485,
ALL OTHER TEXT AND BORDER IS PMS 432. BACKGROUND IS WHITE.
FONT FOR "DESIGNING SOLUTIONS BUILDING TRUST ENRICHING LIVES" TEXT IS
CALIBRI, ALL OTHER TEXT IS AVANTGARDE FONT.
11 131/256" 11 131/256"
/2
DESIGNING SOLUTIONS BUILDING TRUST ENRICHING LIVES
M O
S E
L E
Y A
R C
H
IT
E C
T S
.C O
M
PROJECT NO:
DATE:
N
O R
F O
L K
S T
R E
E T
R
IC
H
M O
N D
V
A
P H
O N
E
-7
F
A X
-5
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
/2
/2
:3 :2
P
M
GENERAL
ARCHITECTURAL
INFORMATION
H . R
. T . J
R . A
R N G R
EA
D
IN
ES
S C
EN
TE
R (T
A R C ) V
IS
IT
O R S C
EN
TE
R
S . G
E O
R G
E M
A S
O N
D R
, A R
L
IN
G T
O N
, V A
A0.1
V A
F M
P N
9-
594303
MAY 27 2020
ARCHITECTURAL ABBREVIATIONS
1/2" = 1'-0"
PROJECT SIGN ELEVATION
1 1/2" = 1'-0"
TEXT LAYOUT ELEVATION
T TREAD
T&G TONGUE & GROOVE
T.O. TOP OF
TB TACKBOARD
TEL TELEPHONE
TERR-C TERRAZZO CEMENTITIOUS
TERR-E TERRAZZO EPOXY
TERR-R TERRAZZO RUBBERIZED
THHD THRESHOLD
THK THICKNESS, THICK
TOS TOP OF STEEL
TOW TOP OF WALL
TS TACK STRIP
TV TELEVISION
TYP TYPICAL
UC UNDERCUT
UG UNDERGROUND
UH UNIT HEATER
UNO UNLESS NOTED (INDICATED) OTHERWISE
VAT VINYL ASBESTOS TILE
VB VAPOR BARRIER
VCT VINYL COMPOSITION TILE
VDB VISUAL DISPLAY BOARD
VERT VERTICAL
VEST VESTIBULE
VFCT VINYL FREE COMPOSITION TILE
VFWC VINYL FREE WALLCOVERING
VR VAPOR RETARDER
VT VINYL TILE
VTR VENT THROUGH ROOF
VWC VINYL WALL COVERING
W WIDE, WIDTH
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WCP WOOD CEILING PANEL
WD WOOD
WDW WINDOW
WP WATERPROOFING
WPT WORKING POINT
WSCT WAINSCOT
WSF WOOD SPORTS FLOORING
WT WEIGHT
WWF WELDED WIRE FABRIC
XPS EXTRUDED POLYSTYRENE
H HIGH
HB HOSE BIBB
HBD HARDBOARD
HDC HOLD DOWN CLIPS
HDNR HARDENER
HDWD HARDWOOD
HDWR HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HPC HIGH PERFORMANCE COATINGS
HPFP HIGH PERFORMANCE FLOOR PAINT
HT HEIGHT
HVAC HEATING, VENTILATING, AIR CONDITIONING
ID INSIDE DIAMETER
IN INCH, INCHES
INCL INCLUDE, INCLUDING
INFO INFORMATION
INST INSTALLATION
INSUL INSULATION
INT INTERIOR
IRWC IMPACT RESISTANT WALL COVERING
IWB INTERACTIVE WHITE BOARD
JAN JANITOR
JCT JUNCTION
JT JOINT
L LENGTH/LONG
LAB LABORATORY
LAHJ LOCAL AUTHORITY HAVING JURISDICTION
LAM LAMINATE
LAV LAVATORY
LH LEFT HAND
LIN LINOLEUM
LKR LOCKER
LMC LINEAR METAL CEILING
LPS LAMINATE PANEL SYSTEM
LT LIGHT
LVR LOUVER
M METER
MACH MACHINE
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MB MARKERBOARD
MCM METAL COMPOSITE MATERIAL
MCP METAL CEILING PANEL
MDO MEDIUM DENSITY OVERLAY
MECH MECHANICAL
MED MEDIUM
MEMB MEMBRANE
MFR MANUFACTURER
MIF MULTICOLOR INTERIOR FINISHING
MIN MINIMUM
MIR MIRROR
MISC MISCELLANEOUS
MLDG MOLDING
MO MASONRY OPENING
MPS MANUAL PROJECTION SCREEN
MR MAP RAIL
MT MOUNT
MTD MOUNTED
MTL METAL
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NO. NUMBER
NOM NOMINAL
NRC NOISE REDUCTION COEFFICIENT
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED CONTRACTOR INSTALLED
OPNG OPENING
OPP HD OPPOSITE HAND
OVHD OVERHEAD
P-TILE PORCELAIN TILE
PC PRECAST
PERF PERFORATED, PERFORATION(S)
PERIM PERIMETER
PIP POURED IN PLACE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLWD PLASTIC LAMINATE WOOD
PLYWD PLYWOOD
PNL PANEL, PANELING
POLY POLYETHYLENE
PPS POWER PROJECTION SCREEN
PPT PRESSURE- OR PRESERVATIVE-TREATED
PR PAIR
PREFAB PREFABRICATED
PREFIN PREFINISHED
PREP PREPARE / PREPARATION
PS PROJECTION SCREEN
PSB PENCIL SHARPENER BLOCK
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PAINT
PTN PARTITION
PTS PNEUMATIC TUBE SYSTEM
PVC POLYVINYL CHLORIDE
PVMT PAVEMENT
PVWC PERFORATED VINYL WALL COVERING
QSM QUARTZ SURFACING MATERIAL
QT QUARRY TILE
QTY QUANTITY
R RISER, RADIUS
R/W RIGHT OF WAY
RAD RADIUS
RAF RESILIENT ATHLETIC FLOORING
RB RESILIENT BASE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REFG REFRIGERATOR
REINF REINFORCING, REINFORCE(D)
REM RECESSED ENTRY MAT
REQ'D REQUIRED
RES RESINOUS FLOORING
RFT RUBBER FLOOR TILE
RH RIGHT HAND
RL RAIN LEADER
RM ROOM
RO ROUGH OPENING
RSF RUBBER SHEET FLOORING
RSR RESILIENT STAIR RISER
RST RESILIENT STAIR TREAD
RT RIGHT
RTU ROOFTOP UNIT
SAB SOUND ATTENUATION BLANKET
SC-PLK SECURITY CEILING PLANK
SC-PNL SECURITY CEILING PANEL
SCH SCHEDULE
SF SQUARE FEET / FOOT
SFRM SPRAYED FIRE RESISTANT MATERIAL
SHM SECURITY HOLLOW METAL
SHTG SHEATHING
SIM SIMILAR
SPEC SPECIFICATION
SPF SPRAYED POLYURETHANE FOAM
SPR SPRINKLER
SQ SQUARE
SQ FT SQUARE FEET / FOOT
SRD SECONDARY ROOF DRAIN
SS STAINLESS STEEL
SSM SOLID SURFACE MATERIAL
ST STREET
STC SOUND TRANSMISSION COEFFICIENT
STD STANDARD
STL STEEL
STRUCT STRUCTURAL
SUSP SUSPENDED
SV SHEET VINYL
SWM SECURITY WOVEN MESH / WOVEN ROD
SYM SYMMETRICAL
A-PT ACCENT PAINT
ABS AIR BARRIER SYSTEM
ABV ABOVE
ACP ACOUSTICAL CEILING PANEL
ACT ACOUSTICAL CEILING TILE
ACW ALUMINUM CLAD WINDOW
ADJ ADJUSTABLE
AFF ABOVE FINISHED FLOOR
AHJ AUTHORITY HAVING JURISDICTION
AHU AIR HANDLING UNIT
ALT ALTERNATE
ALUM ALUMINUM
AP ACCESS PANEL
APC ARCHITECTURAL PRECAST CONCRETE
ARC ABUSE RESISTANT COATING
AS ALUMINUM STOREFRONT
AUTO AUTOMATIC
AVG AVERAGE
AW ALUMINUM WINDOW
AWC ACOUSTICAL WALL COVERING
AWP ACOUSTICAL WALL PANEL
BD BOARD
BF BARRIER FREE (ADA or A117.1)
BLDG BUILDING
BLKG BLOCKING
BOT BOTTOM
BRG BEARING
BTWN BETWEEN
BUR BUILT-UP ROOF
C CARPET
C-TILE CARPET TILE
CAB CABINET
CB CHALKBOARD
CCTV CLOSED CIRCUIT TELEVISION
CEM CEMENT
CFSF-NS COLD FORMED STEEL FRAMING, NON-STRUCTURAL
CFSF-S COLD FORMED STEEL FRAMING, STRUCTURAL
CG CORNER GUARD
CI CONTINUOUS INSULATION
CIPC CAST IN PLACE CONCRETE
CJ CONTROL JOINT
CL CLOSET
CLG CEILING
CLR CLEAR
CM CENTIMETER
CMBD CEMENT BOARD
CMU CONCRETE MASONRY UNIT
CMU-A CONCRETE MASONRY UNIT - ACOUSTICAL
CMU-GF CONCRETE MASONRY UNIT - GROUND FACE
CMU-GLZ CONCRETE MASONRY UNIT - GLAZED
CMU-SPLF CONCRETE MASONRY UNIT - SPLIT FACE
CO CLEANOUT
COL COLUMN
CONC CONCRETE
CONC-P CONCRETE WITH PIGMENT
CONC-SLR CONCRETE WITH SEALER / HARDENER
CONC-ST CONCRETE WITH STAIN
CONST CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACTOR
CORR CORRIDOR
CSMU CAST STONE MASONRY UNIT
CT CERAMIC TILE
CTSK COUNTERSINK, COUNTERSUNK
CU FT CUBIC FEET / FOOT
CUST CUSTODIAN / CUSTODIAL
CW ALUMINUM CURTAIN WALL
CWFD CEMENTITIOUS WOOD FIBER DECK
D DEPTH/DEEP
DBL DOUBLE
DEMO DEMOLITION
DETE DETENTION
DF DRINKING FOUNTAIN
DG DOOR GRILLE
DHM DETENTION HOLLOW METAL
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DIV DIVISION
DL DOOR LOUVER
DN DOWN
DP DAMPPROOFING
DR DISPLAY RAIL
DS DOWNSPOUT
DTL DETAIL
DWG DRAWING
DWR DRAWER
EA EACH
EF EXHAUST FAN
EFS EXTERIOR FINISH SYSTEM
EIFS EXTERIOR INSULATION & FINISH SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELAS ELASTOMERIC
ELEC ELECTRICAL
ELEV ELEVATOR
EMER EMERGENCY
EPS EXPANDED POLYSTYRENE
EPX EPOXY
EQ EQUAL
EQUIP EQUIPMENT
ETR EXISTING TO REMAIN
EWC ELECTRIC WATER COOLER
EX EXISTING
EXH EXHAUST
EXP EXPANSION
EXPC EXPOSED CONSTRUCTION
EXT EXTERIOR
FAAF FLUID APPLIED ATHLETIC FLOORING
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FEB FIRE EXTINGUISHER BRACKET
FEC FIRE EXTINGUISHER CABINET
FF FINISHED FLOOR
FGL FIBERGLASS
FH FIRE HYDRANT
FHC FIRE HOSE CABINET
FHVC FIRE HOSE VALVE CABINET
FIN FINISHED
FLR FLOOR
FLRG FLOORING
FND FOUNDATION
FO FACE OF
FRM FRAME
FRP FIBERGLASS REINFORCED PLASTIC
FRT FIRE RETARDANT TREATED
FT FOOT, FEET
FTG FOOTING
FURN FURNITURE
FVC FIRE VALVE CABINET
FWC FABRIC WALL COVERING
GA GAUGE
GAL GALLON
GALV GALVANIZED
GB GYPSUM BOARD
GB-AR GYPSUM BOARD - ABUSE RESISTANT
GB-IR GYPSUM BOARD - IMPACT RESISTANT
GB-S GYPSUM BOARD - SECURITY
GFRC GLASS FIBER REINFORCED CONCRETE
GFRG GLASS FIBER REINFORCED GYPSUM
GL GLASS, GLAZING
GL-BLK GLASS BLOCK
GPM GALLONS PER MINUTE
GRT GROUT
GSFT GLAZED STRUCTURAL FACING TILE
GT GLASS TILE
GWT GLAZED WALL TILE
GYP GYPSUM
1 1/2" = 1'-0"
ARCHITECT'S SIGN
REVISIONS
DATE DESCRIPTION
OF OBSTRUCTION
REFER TO GENERAL NOTE 'C'
BRACE WALL AS
INDICATED, OR WHERE
NOT INDICATED, AS
APPROVED
BOTTOM
OF DECK
SEALANT SYSTEM: REFER TO
GENERAL NOTE 'C'
MAY
VARY
MAY
VARY
OBSTRUCTION MAY VARY (BEAM, JOIST, GIRDER, CHANNEL, DUCTWORK, PIPING)
HEAD-OF-WALL TERMINATION @ OBSTRUCTION
ENCASEMENT:
REFER TO GENERAL
NOTE 'C'
DO NOT SECURE
ENCASEMENT TO
WALL
CFSF-S W/ GYP BD IN LAYERS AS
REQUIRED TO MAINTAIN ASSEMBLY
RATING CONSISTENT WITH
WALL/PARTITION REQUIREMENTS
PANEL JOINT OR RATED
JOINT SYSTEM AT RATED
PANEL CONSTRUCTION
SUPPORTING
CONSTRUCTION
WILL VARY. PROVIDE
WALL JOINT WHERE
THE SUPPORTING
CONSTRUCTION
CHANGES WITHIN
THE PLANE OF THE
PANEL FINISH
CMU/
CFSF
REFER TO APPLICABLE
GENERAL NOTE 'A' OR 'B'
BOTTOM
OF DECK
OR CAP
HEAD-OF-WALL TERMINATION @ NON-OBSTRUCTION
WALL/PARTITION
MAY VARY
BRACE WALL
AS INDICATED
OR WHERE NOT
INDICATED, AS
APPROVED
CONTINUOUS 3/8" JOINT
W/ SEALANT BOTH SIDES
PANEL JOINT OR
RATED JOINT SYSTEM
AT RATED PANEL
CONSTRUCTION
DIFFERENTIAL
BEARING CMU
INTERSECTIONS
CONTINUOUS 1/4" RAKE
JOINT BOTH SIDES
MORTAR HEAD
JOINT SOLID -
CONTINUOUS
OMIT SEALANT JOINT
WHERE NOT
EXPOSED TO VIEW
NOTE:
PROVIDE WHERE CMU WALLS ON
FOUNDATION WALLS, FOOTINGS OR
THICKENED SLABS INTERSECT CMU WALLS
BEARING ON SLAB-ON-GRADE.
INTERIOR PANEL
FURRING,
WHERE OCCURS
EQUAL
BEARING CMU
INTERSECTIONS
MORTAR HEAD
JOINT SOLID -
CONTINUOUS
RATED/
NON-
RATED
CMU
WALL ORIENTATION
AND FIRE RATING
LOCATIONS WILL
VARY
MAINTAIN JOINT CLEAR
OF MORTAR/GROUT
"TEE" TYPE PREFORMED
CONTROL JOINT GASKET
MECHANICAL ANCHORS
CONTINUOUS 3/8"
JOINT W/ BACKER ROD
& SEALANT AT CMU
RATED
CMU
RATED
CMU
RATED
CMU
NON-
RATED
EXTERIOR
CMU
WYTHE
NON-
RATED
CMU
NON-RATED
CMU
RATED JOINT
ASSEMBLY TO
MATCH RATING OF
WALL, BOTH SIDES
NOTE:
RATED WALLS SHADED FOR CLARITY THIS DETAIL
PANEL JOINT OR RATED
JOINT SYSTEM AT RATED
PANEL CONSTRUCTION
INTERIOR PANEL
FURRING, WHERE
OCCURS
PANEL JOINT OR RATED
JOINT SYSTEM AT RATED
PANEL CONSTRUCTION
INTERIOR PANEL
FURRING, WHERE
OCCURS
CONTINUOUS 1/2" SEALANT
AND BACKER ROD
WALL ASSEMBLY VARIES
AIRSPACE
WALL ASSEMBLY AT
INTERIOR CORNER
WHERE OCCURS
OPEN JOINT
PREFORMED CONTROL
JOINT GASKET
TRANSITION MEMBRANE
WHERE JOINT OCCURS
IN CMU OR SHEATHING
FACE OF CMU OR
SHEATHING
FACE OF BACKUP
PANEL JOINT OR RATED
JOINT SYSTEM AT RATED
PANEL CONSTRUCTION
WHERE OCCURS
CMU
CONTINUOUS JOINT
EACH SIDE AT INTERIOR
CONDITIONS ONLY, OMIT
SEALANT AND BACKER
ROD IN CAVITIES
CONTINUOUS 3/8" JOINT
W/BACKER ROD AND
SEALANT AT CMU
VENEER/
CAVITY
CMU
SUBSTRATE JOINT
WHERE OCCURS
WALL TYPE VARIES
PANEL
PANEL JOINT OR RATED
JOINT SYSTEM AT RATED
PANEL CONSTRUCTION
WHERE OCCURS
PANEL WALL
CFSF/
PANELS
PANEL JOINT OR RATED
JOINT SYSTEM AT RATED
PANEL CONSTRUCTION
WHERE OCCURS
CAVITY INSULATION
AND AIR BARRIER
COMPRESSIBLE FILLER
VENEER
SHEATHING WHERE
INDICATED
TERMINATIONS
WALL JOINTS
A. AT FIRE-, SMOKE-, AND ACOUSTICALLY RATED WALLS: SEAL ALL NON-OBSTRUCTED HEAD-OF-WALL CONDITIONS IN ACCORDANCE WITH JOINT SYSTEM MANUFACTURER’S RECOMMENDATIONS BASED ON CONDITION ENCOUNTERED ( E.G., CMU-TO-DECK (PARALLEL OR PERPENDICULAR TO FLUTES); OR CFSF- TO-DECK (PARALLEL OR PERPENDICULAR TO FLUTES) TO MAINTAIN ASSEMBLY RATING CONSISTENT WITH
WALL/PARTITION REQUIREMENTS. BRACE WALL AS INDICATED OR REQUIRED.
B. AT ALL OTHER WALLS INDICATED TO EXTEND TO UNDERSIDE OF FLOOR/ROOF DECK/CAP: SEAL ALL NON- OBSTRUCTED HEAD-OF-WALL CONDITIONS IN ACCORDANCE WITH JOINT SYSTEM MANUFACTURER’S
RECOMMENDATIONS BASED ON CONDITION ENCOUNTERED ( E.G., CMU-TO-DECK (PARALLEL OR
PERPENDICULAR TO FLUTES); OR CFSF-TO-DECK (PARALLEL OR PERPENDICULAR TO FLUTES). BRACE
WALL AS INDICATED OR REQUIRED.
C. AT ALL WALLS PREVENTED FROM TERMINATING AT THE UNDERSIDE OF FLOOR/ROOF DECK BY
OBSTRUCTIONS, COMPLY WITH THE FOLLOWING:
• AT FIRE-, SMOKE-, AND ACOUSTICALLY-RATED WALLS: ENCASE OBSTRUCTION(S) TO MAINTAIN
ASSEMBLY RATING CONSISTENT WITH WALL/PARTITION REQUIREMENTS.
• AT SECURITY WALLS: TERMINATE IN ACCORDANCE WITH SECURITY PARTITION REQUIREMENTS.
• AT OTHER WALLS: ENCASE OBSTRUCTION(S) ON ONE SIDE.
• SEAL ENCASEMENT TO WALL AND SEAL ENCASEMENT TO DECK IN ACCORDANCE WITH JOINT
SYSTEM MANUFACTURER’S RECOMMENDATIONS AND TO MAINTAIN ASSEMBLY RATING CONSISTENT
WITH WALL/PARTITION REQUIREMENTS.
TERMINATION GENERAL NOTES
A. PLAN DIMENSIONS ARE TO FACE OF WALL OR PARTITION. WHERE APPLIED FINISHES OCCUR-SUCH AS CERAMIC TILE-DIMENSIONS ARE TO FACE OF APPLIED FINISH. FOR WAINSCOTS, FLOOR PLAN DIMENSIONS ARE TO FACE OF WAINSCOT MATERIAL. APPLIED FINISHES ARE NOT ALLOWED TO REDUCE CLEAR DIMENSIONS. “APPLIED FINISHES”
IN THIS CASE DO NOT INCLUDE TRIM, BASE, AND ACOUSTIC WALL PANELS.
B. EXTEND WALL/PARTITION ASSEMBLY COMPONENTS FULL HEIGHT OF ASSEMBLY.
C. ALL INTERIOR CFSF PANEL PARTITIONS: P1 UNLESS INDICATED OTHERWISE.
D. REFER TO STRUCTURAL DRAWINGS AND RELATED SPECIFICATIONS FOR SOLID MASONRY, GROUTING, AND
REINFORCEMENT REQUIREMENTS INCLUDING BUT MAY NOT BE LIMITED TO:
• MASONRY WALLS/PARTITIONS
• LINTELS
• LINTEL BEARING CONDITIONS
• BOND BEAMS
• SHELF BEARING CONDITIONS
• STRUCTURAL REINFORCING REQUIREMENTS
• CHANGES IN WYTHE
E. THE TERMS “WALL” AND “PARTITION” MAY BE USED INTERCHANGEABLY THROUGHOUT THE CONTRACT DOCUMENTS.
F. EXTEND ALL FIRE-, SMOKE-, INCIDENTAL USE-, AND ACOUSTICAL-RATED WALLS/PARTITIONS TO UNDERSIDE OF
FLOOR DECK, ROOF DECK, STRUCTURAL ELEMENT ENCASEMENT OR SOLID CAP ABOVE.
• SEAL AND TERMINATE IN ACCORDANCE WITH JOINT SYSTEM TESTED ASSEMBLIES FOR RESPECTIVE TYPE OF
WALLS/PARTITIONS.
H. PARTITIONS THAT DO NOT EXTEND TO UNDERSIDE OF DECK OR CAP ABOVE:
• EXTEND 4 INCHES MINIMUM ABOVE HIGHEST ADJACENT FINISH CEILING UNLESS INDICATED OTHERWISE.
I. DO NOT CONNECT TIES, ANCHORS, OR REINFORCING TO SINGLE CANTILEVERED FIRE WALL OR BETWEEN
DOUBLE FIRE WALLS.
J. SEAL AROUND ALL PENETRATIONS.
K. COMPLY WITH TERMINATION, WALL JOINT, AND MISCELLANEOUS DETAILS FOR THOSE CONDITIONS WHERE APPLICABLE. COMPLY WITH REFERENCED STANDARDS WHERE DETAILS ARE NOT IDENTIFIED IN THE
DRAWINGS.
L. WALL/PARTITION TYPES DO NOT ADDRESS WALL FINISHES. REFER TO FINISH SCHEDULE.
M. FINISHED SPACES: PROVIDE CHASES AROUND ALL EXPOSED VERTICAL COMPONENTS, INCLUDING BUT NOT LIMITED TO: DUCTWORK, PIPING, AND CONDUIT, UNLESS COMPONENTS ARE SPECIFICALLY INDICATED TO
REMAIN EXPOSED. IF NOT OTHERWISE INDICATED, PROVIDE P2 CHASE CONSTRUCTION.
• HOLD CHASES TIGHT TO COMPONENTS ALLOWING FOR ACCESS, INSULATION, AND TOLERANCES.
• EXTEND CHASES FROM FLOOR TO 4 INCHES MINIMUM ABOVE FINISH CEILING OR IF NO CEILING IS
INDICATED, EXTEND CHASES TO UNDERSIDE OF FLOOR DECK, ROOF DECK, OR SOLID CAP ABOVE AND
TERMINATE ACCORDINGLY.
N. PROVIDE BACKER BOARD/UNIT OF SAME THICKNESS INDICATED IN LIEU OF GYPSUM BOARD PANEL AT
PORTIONS OF WALLS/PARTITIONS TO RECEIVE TILE.
WALL/PARTITION TYPE GENERAL NOTES
A. DRAWINGS MAY INDICATE AESTHETIC AND FUNCTIONAL WALL JOINTS.
B. REFER TO SPECIFICATIONS AND REFERENCED STANDARDS FOR ADDITIONAL WALL JOINT REQUIREMENTS.
• EXTERIOR: LOCATE AS SHOWN ON DRAWINGS
• INTERIOR: LOCATE PER DRAWINGS, IF SHOWN, AND WHERE NOT SHOWN, LOCATE IN ACCORDANCE
WITH SPECIFICATIONS.
• DO NOT ALIGN EXTERIOR JOINTS W/ INTERIOR, BACK-UP WYTHE JOINTS, UNLESS SPECIFICALLY SHOWN
TO ALIGN
C. WALLS AND JOINT TYPES/DETAILS ARE DIAGRAMMATIC. VERIFY ACTUAL FIELD CONDITIONS AND ADJUST
JOINT TYPES/DETAILS IN ACCORDANCE WITH REFERENCED STANDARDS.
D. PROVIDE TESTED JOINT ASSEMBLIES AT FIRE-, SMOKE-, AND ACOUSTICAL-RATED WALLS.
E. WHEN USED HEREIN "RATED" MEANS: FIRE, SMOKE, AND/OR ACOUSTICAL.
AS SHOWN
ON PLAN
AS SHOWN ON
EXTERIOR
ELEVATION
LOCATE JOINT IN VENEER ONLY, NOT IN
INTERIOR BACKUP WYTHE - MATERIALS MAY
VARY. REFER TO WALL JOINT GENERAL
NOTE B FOR EXTERIOR AND INTERIOR WALL
JOINT REQUIREMENTS AND LOCATIONS
WALL JOINT GENERAL NOTES EXTERIOR WALL JOINT GRAPHIC SYMBOLS
PANEL WALL/PARTITION TYPES
Pn
INFORMATIONMARK REMARKS
REPRESENTED BY
P2 --
P1
PROVIDE MOISTURE
RESISTANT GYPSUM BOARD AT
JANITORS CLOSET ABOVE
WAINSCOT. MARK P1A:
362S162-54 STUDS @ 12" OC
FIRE RATED
ASSEMBLY
(REFER TO
LS 1.1 FOR
LEGEND)
4 7/8"
4 1/4"
P3 --
8"
5 1/4"
P4
PROVIDE 400S162-43 STUDS AT
16" OC AT WALL. COORDINATE
WALL BLOCKING WITH LADDER
MANUFACTURER AT
HOLD-DOWN CONNECTION
LOCATIONS
P5 STUD WALLS WITHIN
ARCHITECTURAL COLUMNS
4 5/8"
P6
PROVIDE THIS WALL TYPE AT
JANITORS CLOSET WAINSCOT,
IN ADDITION TO THE OTHER
LOCATIONS INDICATED
5/8" GYP BD
3 5/8" CFSF-NS
5/8" GYP BD
3 5/8" CFSF-NS
5/8" CEMENT BACKER BD
6" CFSF-NS
5/8" GYP BD
4" CFSF-S
5/8" GYP BD
4" CFSF-S
5/8" CEMENT BACKER BD
3 5/8" CFSF-NS
3/16" MORTAR BED
WALL TILE
3/16" MORTAR BED
WALL TILE
5/8" GYPSUM BD
P7 -- 5/8" CEMENT BACKER BD
3/16" MORTAR BED
WALL TILE
7/8" CFSF-NS
1 7/8"
5 1/4"
P8 -- 5/8" CEMENT BACKER BD
3 5/8" CFSF-NS
3/16" MORTAR BED
WALL TILE
± 80' - 0
± 15' - 0"
± 308' - 0"
S O
U T H
G E
O R
G E
M A
S O
N D
R
IV
E
B U
ILD
IN
G O
N E
B U
ILD
IN
G T
W O
P A
R K
IN
G
G A
R A
G E
TRAILER
S O
U T
H G
E O
R G
E M
A S
O N
D R
IV
E
OF RAMP
5' - 0" FROM EDGE
F R
O M
S T
A R
T O
F R
A M
P
F R
O M
F A
C E
O F
C O
L U
M N
B A
S E
M O
S E
L E
Y A
R C
H
IT
E C
T S
.C O
M
PROJECT NO:
DATE:
N
O R
F O
L K
S T
R E
E T
R
IC
H
M O
N D
V
A
P H
O N
E
-7
X
-5
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
/2
/2
:3 :2
P
M
WALL/PARTITION
TYPES, WALL
JOINTS AND
TERMINATIONS
H . R
. T . J
R . A
R N G R
EA
D
IN
ES
S C
EN
TE
R (T
A R C ) V
IS
IT
O R S C
EN
TE
R
S . G
E O
R G
E M
A S
O N
D R
, A R
L
IN
G T
O N
, V A
A0.2
V A
F M
P N
9-
594303
MAY 27 2020
1" = 100'-0"A0.2
PROJECT STAGING2
APPLIES TO THIS DRAWING
1 THE CONTRACTOR SHALL PRESERVE THE HATCHED AREA AS AN UNOBSTRUCTED PASSAGE FOR PEDESTRIANS, AND SHALL PROVIDE TEMPORARY METAL FENCING AT THE BOUNDARY BETWEEN THE HATCHED AREA AND THE WORK AREA FOR THE DURATION OF CONSTRUCTION. THE CONTRACTOR SHALL NOT STORE MATERIALS OR EQUIPMENT IN THIS AREA, AND SHALL CLEAN IT REGULARLY WHEN DIRTIED BY CONSTRUCTION ACTIVITES. WHERE THE SCOPE OF WORK NECESSITIATES WORK IN THE HATCHED AREA, CONTRACTOR SHALL PROVIDE TO THE OWNER A REQUEST FOR CLOSURE WHICH SHALL INCLUDE THE SCHEDULE OF THE CLOSURE AND THE AREA TO BE CLOSED. THIS SHALL BE PROVIDED TO THE OWNER NOT LESS THAN 7 CALENDAR DAYS PRIOR TO THE DESIRED CLOSURE. AREA SHALL NOT BE CLOSED WITHOUT THE APPROVAL OF THE OWNER. TIME IS OF THE ESSENCE - CONTRACTOR SHALL LIMIT CLOSURE OF
THE HATCHED AREA TO THE MINIMUM REQUIRED TO PROVIDE THE WORK SCOPE.
2 IF PROVISION OF THE SCOPE OF WORK REQUIRES THE TEMPORARY CLOSURE OF THE BUS STOP, THE CONTRACTOR SHALL COORDINATE WITH THE LOCAL TRANSPORTATION AUTHORITY AND PROVIDE, AT NO ADDITIONAL COST TO THE OWNER, ANY REQUIREMENTS MANDATED BY THE TRANSPORTATION AUTHORITY, POSSIBLY INCLUDING BUT NOT
LIMITED TO: TEMPORARY SIGNAGE AND PEDESTRIAN SAFEGUARDS.
3 THE CROSSHATCHED AREA MAY BE UTILIZED BY THE CONTRACTOR FOR THE LAYDOWN AND/OR STORAGE OF
PROJECT RELATED MATERIALS AND EQUIPMENT FOR THE DURATION OF THE CONTRACT.
4 CONTRACTOR MAY USE THIS CURB CUT OFF GEORGE MASON DRIVE FOR THE DELIVERY OF MATERIALS AND/OR
EQUIPMENT.
5 THE CONTRACTOR SHALL BE ALLOCATED 2 PARKING SPACES FOR THE DURATION OF CONSTRUCTION TO USE FOR THE
PARKING OF VEHICLES ONLY. ADDITIONAL PARKING MUST BE LOCATED OFFSITE.
6 CONTRACTOR MAY UTILIZE THE HATCHED AREA FOR TRAILER AND/OR DUMPSTER LOCATION FOR THE DURATION OF
THE CONTRACT
7 CONTRACTOR SHALL PROTECT TREES FROM DAMAGE THROUGHOUT THE COURSE OF CONSTRUCTION. ALL
DISTURBED HARDSCAPE AND VEGETATION SHALL BE RESTORED UPON CONTRACT COMPLETION.
8 SECURE PERIMETER. COORDINATE WITH THE OWNER TO DETERMINE THE METHODS FOR MAINTAINING SITE SECURITY.
THIS MIGHT INCLUDE, BUT IS NOT LIMITED TO, THE PRESENTATION OF IDENTIFICATION FOR ALL INDIVIDUALS WORKING ON BASE, A LIST OF STAFF MEMBERS EXPECTED TO ACCESS THE SITE, AND THE VISUAL INSPECTION OF MATERIALS
AND EQUIPMENT BROUGHT ONTO THE SITE.
9 CONTRACTOR MAY NOT OBSTRUCT VEHICLE ACCESS TO THE PARKING GARAGE. IF THE WORK SCOPE NECESSITATES THE CLOSURE OF THIS ACCESS DRIVE, AT LEAST ONE LANE MUST REMAIN OPEN WHILE THE WORK IS UNDERTAKEN.
THE CONTRACTOR SHALL PROVIDE A METHOD TO CONDUCT VEHICULAR FLOW INTO/OUT OF THE GARAGE DURING THE
LANE CLOSURE.
10 THIS TRAILER IS EXISTING AND USED BY THE OWNER; NOT INTENDED FOR USE BY CONTRACTOR.
11 PROJECT LOCATION. THE HOURS OF CONSTRUCTION SHALL BE LIMITED TO MONDAY THROUGH FRIDAY 06:00 - 16:00. IF THE CONTRACTOR WISHES TO WORK OUTSIDE OF THESE HOURS, THE CONTRACTOR SHALL SUBMIT A REQUEST TO THE OWNER AT LEAST THREE DAYS PRIOR TO THE ANTICIPATED WORK, WHICH SHALL INCLUDE THE PROPOSED SCHEDULE AND ACTIVITY, AND THIS REQUEST MUST BE APPROVED IN WRITING BY THE OWNER.
1" = 30'-0"A0.2
PEDESTRIAN SITE USAGE DIAGRAM16
S O
U T
H G
E O
R G
E M
A S
O N
D R
IV
E
5 6
11 13
M O
S E
L E
Y A
R C
H
IT
E C
T S
.C O
M
PROJECT NO:
DATE:
N
O R
F O
L K
S T
R E
E T
R
IC
H
M O
N D
V
A
P H
O N
E
-7
X
-5
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
/2
/2
:3 :2
P
M
SITE PLAN
H . R
. T . J
R . A
R N G R
EA
D
IN
ES
S C
EN
TE
R (T
A R C ) V
IS
IT
O R S C
EN
TE
R
S . G
E O
R G
E M
A S
O N
D R
, A R
L
IN
G T
O N
, V A
A1.0
V A
F M
P N
9-
594303
MAY 27 2020
1/8" = 1'-0"A1.0
SITE PLAN1
APPLIES TO DRAWINGS A1.0
1 ETR VEHICULAR SECURITY SCREENING CANOPY
2 GARDEN, OPEN TO SKY
3 ETR BUS STOP SHELTER
4 SIGN POST WITH SIGNAGE TYPE C*. INCLUDED IN ADDITIVE BID ITEM 4.
REFER TO A3.3
5 SIGN POST WITH SIGNAGE TYPE C. REFER TO A3.3
6 SIGN POST WITH SIGNAGE TYPE G AND METAL LOCKBOX WITH SLOT
FOR BADGE RETURN. REFER TO A 3.3
7 STAIRS FROM PARKING GARAGE, INCLUDED IN ADDITIVE BID ITEM 4.
REFER TO CIVIL DOCUMENTS
8 RAMP FROM PARKING GARAGE, INCLUDED IN BASE BID. REFER TO CIVIL
DOCUMENTS
9 ETR VEHICULAR GATE
10 ETR C-SECTION PICKET PERIMETER FENCE
11 C-SECTION PICKET PERIMETER FENCE. REFER TO CIVIL DOCUMENTS
12 ETR VEHICULAR CABLE BARRIER
13 VEHICULAR CABLE BARRIER. REFER TO CIVIL DOCUMENTS
14 AUTO DOOR ACTUATOR MOUNTED ON BOLLARD CONNECTED TO DOOR
02A
15 ETR PARKING GARAGE
E
C
FEC
A4.1
A4.1 5
A4.1
A4.18
A7.1
A5.1.2
A5.1.4
A5.1.2
A5.1.3
A5.1.3
A2.3
A5.1.5
A5.1.5
A5.1.5
A5.1.2
A5.1.3
A5.1.3
A5.1.3
A4.1 4
03A
CAC OFFICE
SUPERVISOR
OFFICE
ADMIN WORK
AREA
IT ROOM
ELEC/MECH
ROOM
VISITOR
CORRIDOR
PUBLIC TOILET
STAFF TOILET
SECURITY
SCREENING
VESTIBULE
CAC
RECEPTIONIST
EXTERIOR
GARDEN
BREAK ROOM
01A
01B
12A
02A
04B
03C
03D
08A
08B
04A
16A
17A
18A
WAITING
ROOM
HELP DESK
STAFF
CORRIDOR
JANITORS
CLOSET
ADMIN
WORKSTATION
14A
11A
15A
10A
06A
07A
1' - 0 7/8" 10 3/4"
12' - 2 3/4" 2' - 10 3/4" 5' - 0" 39' - 4" 5' - 0" 6' - 4"
72' - 9 1/8"
1' - 0 7/8" 1' - 1" 7' - 3 3/4" 9' - 0"
4' - 6 3/8" TO EXTERIOR FACE OF CMU
6' - 5 1/8" TO CMU BELOW
8' - 4" 6' - 10" 5' - 0" 1' - 4" 8' - 0" 10' - 0" 3' - 10"
72' - 9 1/8"
/8
/4
/8
/4
8' - 6"
7' - 11 1/8" 14' - 8 1/2"
10' - 10"
10' - 7 1/2" 5' - 0"
/8
/4
14' - 6"9' - 2"
5' - 0"
.0
A A
C C
B B
A2.3
F F
E E
A2.2
A2.2
A2.2
A2.2
A2.2
03B
A5.1.2
A5.1.4
A5.1.3
A8.111
A8.1
A8.1
A3.02
7' - 7 1/4"
(M
IN
H
O L D
'-2
/2
4' - 0"
8' - 0" 10' - 0" 3' - 10"
A2.1
PEDESTRIAN
CHECK
WINDOW
03B
A8.1
A8.1
G G
D D
A2.1
A5.1.3
05A
A2.1
A2.4
A2.4
A2.4
A2.4
A2.4
A5.1.4
A5.1.4
A5.1.4
P4
1' - 0"
A2.1
A2.4
10' - 5"
00A
00B
2± 9' - 5 3/4" VIF
V
IF
/2 " 6
A2.1
± 5' - 6 1/4" VIF
A2.4
A2.4
58' - 6 3/4"
/4
2' - 10"
19' - 2 3/4" 8' - 4"
7' - 0"
1' - 8"
4' - 0"
9' - 2 5/8"
A5.1.2
1' - 11 5/8"
AS
AS
AS
AS
AS
AS
AS
AS
AS
AS
AS
AS
WA1
WA1
WA1 WA1
WA5
WA5
WA5
WA1
WA1
WA1
WA1
WA1
WA1WA1
WA1
A2.3
OPP
TERMINATE WITHIN 6" OF ETR GATE
8' - 6"
/4
BLOCKING LENGTH
4' - 11 69/256" TV
7 3/4" 5 3/4"
/4
1' - 1 1/2"
1' - 0"
4' -
8' - 6"
1' - 0"
1' - 0"
.0
REFER TO CIVIL DOCUMENTS FOR
ADDITIONAL INFORMATION AND
PLANTING PLAN
01B
04B
02A
R O
6"
3' - 8"
T Y
P
A2.1
Level 1 0"
WA11 E
X
IS
T
IN
G
P A
V E
M E
N T
M A
IN
T
A
IN
O F
F S
E T
F R
O M
5' - 2 3/8" UNO
E Q
E Q
A F
F
FINISHED FLOOR
A5.1.2
A8.1
6' - 3 1/8" RO
A5.1.2
A2.4
1' - 10 1/4" 3' - 8"
AS
AS
AS
AS
/8
R O
1' - 3"
3"
PEDESTRIAN
CHECK
WINDOW
03B
03B
A2.110
W
ID
T H
O F
T U
R N
S T
IL
E
P E
R M
A N
U F
A C
T U
R E
R
00A
00B
05A
T E
R M
IN
A
T E
W
IT
H
IN
O F
W A
L L
M A
T C
H E
X
IS
T
IN
G
R E
F E
R T
O C
IV
IL
D O
C U
M E
N T
S
H E
IG
H
T O
F C
-S E
C T
IO
N
P
IC
K E
T F
E N
C E
S H
A L L
M O
S E
L E
Y A
R C
H
IT
E C
T S
.C O
M
PROJECT NO:
DATE:
N
O R
F O
L K
S T
R E
E T
R
IC
H
M O
N D
V
A
P H
O N
E
-7
X
-5
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
/2
/2
:3 :3
P
M
FIRST FLOOR
PLAN
H . R
. T . J
R . A
R N G R
EA
D
IN
ES
S C
EN
TE
R (T
A R C ) V
IS
IT
O R S C
EN
TE
R
S . G
E O
R G
E M
A S
O N
D R
, A R
L
IN
G T
O N
, V A
A2.1
V A
F M
P N
9-
594303
MAY 27 2020
1/4" = 1'-0"A2.1
FLOOR PLAN2
APPLIES TO DRAWING A2.1
1 PERMANENT, OSHA COMPLIANT, GALVANIZED STEEL LADDER, INCLUDED IN
ADDITIVE BID ITEM TWO
2 PROVIDE WA11 WALL TYPE AT EXISTING GARAGE WALL, INCLUDED IN ADDITIVE BID
ITEM ONE. BASE OF WALL SHALL FOLLOW THE SLOPE OF THE RAMP; THE
WATERTABLE SHALL REMAIN LEVEL FOR THE LENGTH OF THE WALL
3 ARCHITECTURAL PRECAST CONCRETE WATERTABLE
4 REMOVE PORTION OF EXPOSED PARKING GARAGE CONCRETE RETAINING WALL
AND METAL GUARDRAIL BETWEEN PIERS AT SECOND FLOOR. ADDITIVE BID ITEM
ONE INCLUDES MANUFACTURED STONE VENEER WHICH WILL COVER THE CUT
PORTIONS OF THE EXISTING WALLS. THE BASE BID SHALL INCLUDE CONCRETE
PATCHING AND REPAIR OF THE CUT AREA OF THE WALLS AND SLAB SUCH THAT IT
IS FREE FROM TRIP HAZARDS AND PROVIDES A DURABLE, LEVEL, AND CONTINUOUS
CONCRETE SURFACE AT ALL SIDES OF THE OPENING. APPROXIMATE VOLUME OF
CONCRETE TO BE REMOVED IS EIGHT CUBIC FEET
5 ELECTRONIC EQUIPMENT OR APPLIANCE, NIC
6 METAL LOCK BOX WITH SLOT FOR BADGE RETURN. MOUNT TO EXISTING STEEL
COLUMN SO THAT BADGE SLOT IS AT 45" AFF
7 PROVIDE FASTENERS TO SECURE ROOF MEMBRANE TO WOOD BLOCKING
8 LAP EPDM FLASHING MEMBRANE OVER THE ROOF MEMBRANE. TERMINATE BEHIND
HATCH METAL FLASHING
9 PREMANUFACTURED 30" x 36" ROOF HATCH
10 PROVIDE TV BLOCKING
11 FULL HEIGHT PAINTED GALVANIZED STEEL TURNSTILE
12 C-SECTION PICKET FENCE. REFER TO CIVIL DOCUMENTS
13 FREESTANDING REMOVABLE STANCHION WITH RETRACTABLE FABRIC STRAP
14 CONCRETE WALKWAY
15 1/2" PLYWOOD FLUSH WITH FACE OF STUD
16 2" x 6" WOOD BLOCKING
17 ARCHITECTURAL PRECAST CONCRETE SILL. NO JOINTS ALLOWED FOR THE FULL
LENGTH OF SILL
18 SOLID SURFACE WINDOW STOOL
19 AUTO DOOR ACTUATOR. MOUNT CENTER OF PLATE 48" AFF
20 CARD READER CONTROLLED LOCK
21 HORIZONTAL BRACING ABOVE GATE
22 PAINTED GALVANIZED STEEL 3'-6" WIDE GATE
23 2-1/2" GROMMETS, TYPICAL
24 RIP RAP STONE. REFER TO 12/A5.1.4
1 1/2" = 1'-0"A2.1 A2.1
DETAIL3
1/4" = 1'-0"A2.1 A2.1
GARDEN COURTYARD HARDSCAPE PLAN1
ADDITIVE BID ITEMS
HEREIN PROVIDES A GENERAL DESCRIPTION OF THE ADDITIVE BID ITEMS:
1. MANUFACTURED STONE VENEER AND ARCHITECTURAL PRECAST CONCRETE
WATERTABLES WHERE INDICATED IN THE DRAWINGS. BASE BID SHALL INCLUDE EIFS
AT THESE LOCATIONS. REFER TO WALL ASSEMBLIES SCHEDULE AND BUILDING
ELEVATIONS.
2. A PERMANENT LADDER AT MECH/ELEC ROOM AND A ROOF HATCH.
3. ONE OF EACH LARGE, EXTERIOR MEDALLIONS OF NGB AND ARNG LOGOS AT SOUTH
GEORGE MASON FACADE; REFER TO A3.3 AND BUILDING ELEVATIONS.
4. EXTERIOR STAIRS AND ASSOCIATED HANDRAILS TO CONNECT TO THE EXISTING
PARKING GARAGE, AND A SIGN MOUNTED TO SIGN POST. REFER TO CIVIL DOCUMENTS,
SITE PLAN, AND A3.3.
NOTE: DRAWINGS WITHIN ARCHITECTURAL SET ARE DRAWN AS THOUGH ALL ADDITIVE
BID ITEMS ARE INCLUDED.
1/2" = 1'-0"A2.1 A2.1
SECTION5
1/2" = 1'-0"A2.1 A2.1
SECTION6
1" = 1'-0"A2.1 A2.1
DETAIL4
1" = 1'-0"A2.1
TV BLOCKING7
1/2" = 1'-0"A2.1 A2.1
ENLARGED PLAN - SECURITY SCREENING8
1/2" = 1'-0"A2.1 A2.1
PLAN9
1/2" = 1'-0"A2.1 A2.1
ELEVATION10
CANOPY ROOF
11' - 0"
CANOPY ROOF
11' - 0"
A2.2
A2.2
8A2.2
A2.2
A2.2
A2.2
1' - 4 1/2"
/1
/2
9 3/4"
6"
/4
/4
1' - 4 1/2"
/4
/4
11922
T.O. PARAPET
15' - 4"
CANOPY ROOF
11' - 0"
A2.2
A2.2
T.O. PARAPET
15' - 4"
CANOPY ROOF
11' - 0"
1' - 8"
CANOPY ROOF
11' - 0"
A2.2
A2.2
A2.2
01A03A05A
A2.4
A2.4
1' - 7 1/8"
1/2"
/1
9 3/4"
/2
/4
1' - 4 1/2"
A2.2
1' - 4 1/2"
/1
/2
/1
/4
1 1/4"
1/2"
5 1/2"
/1
/1
9 3/4"
/2
/2
/1
/1
/4
3/8"
UTILIZE THIS REVEAL PROFILE FOR BOTH HORIZONTAL AND VERTICAL
REVEALS. WHERE A HORIZONTAL REVEAL INTERSECTS A VERTICAL
REVEAL, THE VOID THE AT INTERSECTION SHALL BE PRYRAMIDAL.
REFER TO INTERSECTION ELEVATION
INTERSECTION ELEVATION SECTION PROFILE
.0
.0
M O
S E
L E
Y A
R C
H
IT
E C
T S
.C O
M
PROJECT NO:
DATE:
N
O R
F O
L K
S T
R E
E T
R
IC
H
M O
N D
V
A
P H
O N
E
-7
X
-5
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
/2
/2
:3 :4
P
M
CANOPY
SECTIONS AND
DETAILS
H . R
. T . J
R . A
R N G R
EA
D
IN
ES
S C
EN
TE
R (T
A R C ) V
IS
IT
O R S C
EN
TE
R
S . G
E O
R G
E M
A S
O N
D R
, A R
L
IN
G T
O N
, V A
A2.2
V A
F M
P N
9-
594303
MAY 27 2020
1/4" = 1'-0"A2.1 A2.2
SECTION3
1/4" = 1'-0"A2.1 A2.2
SECTION12
1 1/2" = 1'-0"A2.2 A2.2
SECTION8
1 1/2" = 1'-0"A2.2 A2.2
SECTION6
1/4" = 1'-0"A2.1 A2.2
SECTION10
1/4" = 1'-0"A2.1 A2.2
SECTION4
1/4" = 1'-0"A2.1 A2.2
SECTION5
APPLIES TO DRAWINGS A2.2 - A2.4 & A5.1.2 - A5.1.4
1 SELF ADHERED FLEXIBLE FLASHING MEMBRANE
2 CFSF-S. REFER TO STRUCTURAL
3 ALUMINUM RAINLEADER
4 VERTICALLY ORIENTED GROUND FACE CMU
5 GROUND FACE CMU
6 EIFS REVEAL
7 ALUMINUM 3/8" x 1/2" TRIM
8 EIFS. COLOR SHALL MATCH TARC BUILDING ONE
9 ALUMINUM CONDUCTOR HEAD
10 PREMANUFACTURED COPING
11 WET SEAL MCM PANEL JOINTS
12 FLASHING WITH DRIP EDGE SET INTO CONTINUOUS BED OF SEALANT. DRIP EDGE WITH
HEMMED EDGES, FORM DRIP (TURN DOWN IMMEDIATELY AT FACE OF WALL - DO NOT
PROVIDE A FLAT SURFACE BEFORE FORMING DRIP)
13 5/8" EXTERIOR WALL SHEATHING
14 MECHANICAL CEILING ATTACHMENT FASTENED DIRECTLY TO STUDS
15 2" WATER DRAINABLE EIFS SYSTEM
16 1/2" RECESSED BOND BREAK FILLER AND SEALANT. ANGLE TOP OF SEALANT SO THAT IT
SHEDS WATER AWAY FROM THE BUILDING.
17 DO NOT PROVIDE METAL THROUGH WALL FLASHING AT THIS WATERTABLE. MAINTAIN
CONTINUOUS DRAINAGE LAYER BETWEEN THE STACKED WALL TYPES
18 TERMINATE EIFS AT EDGE OF MCM. PROVIDE ROOF MEMBRANE AT THE REMAINDER OF
THE COLUMN FACE
19 FLUID APPLIED AWV BARRIER
20 WELDED SCUPPER SLEEVE
21 ICE/WATER SHIELD
22 MCM PANEL. IF THE PANEL LENGTH AT THE INSIDE EDGE OF THE CANOPY PARAPET
NEAR THE TRANSITION TO THE ROOFING MEMBRANE IS LESS THAN THE APPROVED
MANUFACTURER'S MINIMUM, RAISE THE HEIGHT OF THE CANOPY PARAPET TO MEET
THE MINIMUM REQUIREMENT AT NO ADDITIONAL COST TO THE OWNER
23 DAMPPROOFING. START AT BASE OF WALL FLASHING OR TOP OF EXTERIOR SLAB,
WHICHEVER IS HIGHER, AND EXTEND DOWN TO TOP OF FOOTING
24 SLOPE TOP OF WD BLOCKING
25 BACKER ROD AND SEALANT
26 PROVIDE 1" ISOLATION JOINT AROUND ENTIRE BEAM PENETRATION. FILL WITH
COMPRESSIBLE SEALANT
27 SOLID SURFACE WINDOW STOOL
28 TAPER TOP OF RIGID BOARD CAVITY-WALL INSULATION
29 GYP BD SILL
30 ALUMINUM GUTTER
31 1/2" ROOF SHEATHING
32 1 5/8" CFSF-NS
33 PREMANUFACTURED FASCIA
34 REFER TO STRUCTURAL FOR LOCATION OF SLAB DEPRESSIONS. COORDINATE WITH
MANUFACTURER'S RECOMMENDATIONS FOR DEPRESSION DEPTH
35 FASTEN ROOFING MEMBRANE TO A LAYER OF GYP SHEATHING AND BLOCKING AT THE
EDGE OF THE COLUMN. GYP SHEATHING SHALL RUN FROM THE TOP OF THE WOOD
BLOCKING TO THE UNDERSIDE OF THE DECK. WRAP FLASHING OVER TOP OF ROOFING
MEMBRANE
36 PROVIDE L5x3-1/2x5/16 "(LLV) SILL ANGLE W/ 5/8" DIAM SCREW ANCHORS (4" EMBED) AT
EACH END AND AT 16" OC
37 NOTCH EIFS TO ALLOW FOR ROOF FASTENER, METAL COUNTER FLASHING, AND
SEALANT
38 NOTCH EIFS TO PROVIDE CONTINUOUS TERM BAR AND SEALANT
39 WEEP INSERT
40 MANUFACTURED STONE VENEER. PROVIDE PREFORMED CORNERS AT ALL CORNERS
41 3" x 2" 16 GAGE PLATE CLOSURE ANGLE
42 3" x 3" 16 GAGE PLATE CLOSURE ANGLE
43 2" x 2" 16 GAGE PLATE CLOSURE ANGLE
44 1 3/4" x 1 3/4" 16 GAGE PLATE CLOSURE ANGLE
45 PROVIDE THREE CONTINUOUS ROWS OF SEALANT. AT LEAST ONE ROW MUST BE AT THE
INTERIOR CONCRETE, AND AT LEAST ONE ROW MUST BE AT THE EXTERIOR CONCRETE
46 STOREFRONT SILL FLASHING WITH END DAMS
47 PROVIDE CONTINUOUS STRIP OF RIP-RAP TO MATCH STONE AT NEARBY GARDEN
DRAINS, REFER TO CIVIL DOCUMENTS. PROVIDE FOR THE FULL LENGTH OF THE
ADJACENT ARCHITECTURAL PRECAST SHAPE, CONTAINED BY METAL LANDSCAPE
EDGING
48 DOOR THRESHOLD
49 COUNTERTOP. REFER TO A8.1
50 EIFS EXPANSION JOINT
51 PROVIDE 1/2" RIGID INSULATION BETWEEN SLABS. WHERE POSSIBLE, EXTEND 2" BELOW
THE BOTTOM OF THE INTERIOR SLAB
52 SS DEAL TRAY WITH SLIDING TRANSACTION TRAY
53 WEATHERSTRIPPING
54 AUTO DOOR ACTUATOR. MOUNT CENTER OF PLATE 48" AFF
55 TRANSITION STRIP
56 PROVIDE 3 1/2" x 7 LEGS (LLV) WITH 5/8" DIAMETER SCREW ANCHORS (4" EMBED) AT
EACH END AND AT 16" OC
57 STEP FLASHING AS REQUIRED. MAINTAIN MINIMUM 6" BETWEEN FLASHING AND FINISHED
GRADE OR PAVEMENT
58 TWO CONTINUOUS ROWS OF SEALANT ATOP DRIP EDGE AND BELOW FLEXIBLE
FLASHING MEMBRANE
59 FINISH FLOORING. REFER TO A3.0
60 WALL BASE. REFER TO A3.0
61 COPING TO WALL COUNTERFLASHING, SET INTO TWO CONTINUOUS ROWS OF SEALANT
62 CONTINUOUS SLAB AT OPENING
63 ROOFING MEMBRANE
64 MAINTAIN CONTINUOUS INSULATION
1 1/2" = 1'-0"A2.2 A2.2
SECTION1
1 1/2" = 1'-0"A2.2 A2.2
SECTION9
1 1/2" = 1'-0"A2.2 A2.2
SECTION2
3" = 1'-0"A2.2 A2.2
DETAIL7
TYP 6" = 1'-0"A2.2
TYPICAL EIFS REVEAL11
C R
CANOPY ROOF
11' - 0"
/2
/4
1' - 3 15/16" 1' - 3 15/16"
1' - 6" 1' - 6"
1' - 5 1/2" 1' - 5 1/2"
1' - 5 1/2"1' - 5 1/2"
1/2"
1/2"
1/2"
23 23
CANOPY ROOF
11' - 0"
9 15/16" 9 15/16"
9 15/16" 1' - 0"
9 15/16" 11 1/2"
9 15/16" 1' - 0"
1' - 0" 1' - 0"
11 1/2" 11 1/2"
/8
/8
/2
A2.3
A2.3
7 5/8" 1' - 0 3/8" 11 13/16" 9/16"
3 5/8"
3' - 0"
/8 " 9
/1
/8
/1
"7
/8
/8
/8
/1
/8
/8
/8
/1
/8
/8
1/2"
1' - 3 5/8"
9/16"
1' - 3 5/8"
9/16"
3 5/8"
CANOPY ROOF
11' - 0"
A2.4
2' - 9 7/8"
3' - 0"
2' - 11 1/2"
CANOPY ROOF
11' - 0"
A2.3
A2.3
A2.3
9 7/8"9 7/8"
1' - 0"9 7/8"
11 1/2"9 7/8"
1' - 0"9 7/8"
11 1/2" 11 1/2"
A2.3
A2.3
/8
/8
/8
/8
/8
3 5/8"
3/8"
3 13/16"
3/8"
7 5/8"
3/8"
3 13/16"
3/8"
3 5/8"
2' - 0"
/2
/2
/2
/2
5 13/16"
9/16"
T E
R M
IN
A
T E
S U
B S
T R
A T
E
A
F F
1/2"
1/2" AIR CAVITY
M O
S E
L E
Y A
R C
H
IT
E C
T S
.C O
M
PROJECT NO:
DATE:
N
O R
F O
L K
S T
R E
E T
R
IC
H
M O
N D
V
A
P H
O N
E
-7
X
-5
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
/2
/2
:3 :4
P
M
CANOPY
SECTIONS AND
DETAILS
H . R
. T . J
R . A
R N G R
EA
D
IN
ES
S C
EN
TE
R (T
A R C ) V
IS
IT
O R S C
EN
TE
R
S . G
E O
R G
E M
A S
O N
D R
, A R
L
IN
G T
O N
, V A
A2.3
V A
F M
P N
9-
594303
MAY 27 2020
1 1/2" = 1'-0"A2.3 A2.3
SECTION1
1 1/2" = 1'-0"A2.3 A2.3
SECTION4
APPLIES TO DRAWINGS A2.2 - A2.4 & A5.1.2 - A5.1.4
1 SELF ADHERED FLEXIBLE FLASHING MEMBRANE
2 CFSF-S. REFER TO STRUCTURAL
3 ALUMINUM RAINLEADER
4 VERTICALLY ORIENTED GROUND FACE CMU
5 GROUND FACE CMU
6 EIFS REVEAL
7 ALUMINUM 3/8" x 1/2" TRIM
8 EIFS. COLOR SHALL MATCH TARC BUILDING ONE
9 ALUMINUM CONDUCTOR HEAD
10 PREMANUFACTURED COPING
11 WET SEAL MCM PANEL JOINTS
12 FLASHING WITH DRIP EDGE SET INTO CONTINUOUS BED OF SEALANT. DRIP EDGE WITH
HEMMED EDGES, FORM DRIP (TURN DOWN IMMEDIATELY AT FACE OF WALL - DO NOT
PROVIDE A FLAT SURFACE BEFORE FORMING DRIP)
13 5/8" EXTERIOR WALL SHEATHING
14 MECHANICAL CEILING ATTACHMENT FASTENED DIRECTLY TO STUDS
15 2" WATER DRAINABLE EIFS SYSTEM
16 1/2" RECESSED BOND BREAK FILLER AND SEALANT. ANGLE TOP OF SEALANT SO THAT IT
SHEDS WATER AWAY FROM THE BUILDING.
17 DO NOT PROVIDE METAL THROUGH WALL FLASHING AT THIS WATERTABLE. MAINTAIN
CONTINUOUS DRAINAGE LAYER BETWEEN THE STACKED WALL TYPES
18 TERMINATE EIFS AT EDGE OF MCM. PROVIDE ROOF MEMBRANE AT THE REMAINDER OF
THE COLUMN FACE
19 FLUID APPLIED AWV BARRIER
20 WELDED SCUPPER SLEEVE
21 ICE/WATER SHIELD
22 MCM PANEL. IF THE PANEL LENGTH AT THE INSIDE EDGE OF THE CANOPY PARAPET
NEAR THE TRANSITION TO THE ROOFING MEMBRANE IS LESS THAN THE APPROVED
MANUFACTURER'S MINIMUM, RAISE THE HEIGHT OF THE CANOPY PARAPET TO MEET
THE MINIMUM REQUIREMENT AT NO ADDITIONAL COST TO THE OWNER
23 DAMPPROOFING. START AT BASE OF WALL FLASHING OR TOP OF EXTERIOR SLAB,
WHICHEVER IS HIGHER, AND EXTEND DOWN TO TOP OF FOOTING
24 SLOPE TOP OF WD BLOCKING
25 BACKER ROD AND SEALANT
26 PROVIDE 1" ISOLATION JOINT AROUND ENTIRE BEAM PENETRATION. FILL WITH
COMPRESSIBLE SEALANT
27 SOLID SURFACE WINDOW STOOL
28 TAPER TOP OF RIGID BOARD CAVITY-WALL INSULATION
29 GYP BD SILL
30 ALUMINUM GUTTER
31 1/2" ROOF SHEATHING
32 1 5/8" CFSF-NS
33 PREMANUFACTURED FASCIA
34 REFER TO STRUCTURAL FOR LOCATION OF SLAB DEPRESSIONS. COORDINATE WITH
MANUFACTURER'S RECOMMENDATIONS FOR DEPRESSION DEPTH
35 FASTEN ROOFING MEMBRANE TO A LAYER OF GYP SHEATHING AND BLOCKING AT THE
EDGE OF THE COLUMN. GYP SHEATHING SHALL RUN FROM THE TOP OF THE WOOD
BLOCKING TO THE UNDERSIDE OF THE DECK. WRAP FLASHING OVER TOP OF ROOFING
MEMBRANE
36 PROVIDE L5x3-1/2x5/16 "(LLV) SILL ANGLE W/ 5/8" DIAM SCREW ANCHORS (4" EMBED) AT
EACH END AND AT 16" OC
37 NOTCH EIFS TO ALLOW FOR ROOF FASTENER, METAL COUNTER FLASHING, AND
SEALANT
38 NOTCH EIFS TO PROVIDE CONTINUOUS TERM BAR AND SEALANT
39 WEEP INSERT
40 MANUFACTURED STONE VENEER. PROVIDE PREFORMED CORNERS AT ALL CORNERS
41 3" x 2" 16 GAGE PLATE CLOSURE ANGLE
42 3" x 3" 16 GAGE PLATE CLOSURE ANGLE
43 2" x 2" 16 GAGE PLATE CLOSURE ANGLE
44 1 3/4" x 1 3/4" 16 GAGE PLATE CLOSURE ANGLE
45 PROVIDE THREE CONTINUOUS ROWS OF SEALANT. AT LEAST ONE ROW MUST BE AT THE
INTERIOR CONCRETE, AND AT LEAST ONE ROW MUST BE AT THE EXTERIOR CONCRETE
46 STOREFRONT SILL FLASHING WITH END DAMS
47 PROVIDE CONTINUOUS STRIP OF RIP-RAP TO MATCH STONE AT NEARBY GARDEN
DRAINS, REFER TO CIVIL DOCUMENTS. PROVIDE FOR THE FULL LENGTH OF THE
ADJACENT ARCHITECTURAL PRECAST SHAPE, CONTAINED BY METAL LANDSCAPE
EDGING
48 DOOR THRESHOLD
49 COUNTERTOP. REFER TO A8.1
50 EIFS EXPANSION JOINT
51 PROVIDE 1/2" RIGID INSULATION BETWEEN SLABS. WHERE POSSIBLE, EXTEND 2" BELOW
THE BOTTOM OF THE INTERIOR SLAB
52 SS DEAL TRAY WITH SLIDING TRANSACTION TRAY
53 WEATHERSTRIPPING
54 AUTO DOOR ACTUATOR. MOUNT CENTER OF PLATE 48" AFF
55 TRANSITION STRIP
56 PROVIDE 3 1/2" x 7 LEGS (LLV) WITH 5/8" DIAMETER SCREW ANCHORS (4" EMBED) AT
EACH END AND AT 16" OC
57 STEP FLASHING AS REQUIRED. MAINTAIN MINIMUM 6" BETWEEN FLASHING AND FINISHED
GRADE OR PAVEMENT
58 TWO CONTINUOUS ROWS OF SEALANT ATOP DRIP EDGE AND BELOW FLEXIBLE
FLASHING MEMBRANE
59 FINISH FLOORING. REFER TO A3.0
60 WALL BASE. REFER TO A3.0
61 COPING TO WALL COUNTERFLASHING, SET INTO TWO CONTINUOUS ROWS OF SEALANT
62 CONTINUOUS SLAB AT OPENING
63 ROOFING MEMBRANE
64 MAINTAIN CONTINUOUS INSULATION
1 1/2" = 1'-0"A2.1 A2.3
PLAN2
1 1/2" = 1'-0"A2.3 A2.3
SECTION8
1 1/2" = 1'-0"A2.3 A2.3
SECTION6
1 1/2" = 1'-0"A2.1 A2.3
PLAN7
3" = 1'-0"A2.3 A2.3
DETAIL9
3" = 1'-0"A2.3 A2.3
DETAIL3
3" = 1'-0"A2.3 A2.3
DETAIL5
T.O. PARAPET
15' - 4"
1 1/2"
/2
1 1/2"
/4
EQ EQ
EQ EQ
/2
2' - 1 7/8"
1' - 4"
1 1/2"
/2
/4
/2
1' - 4"
50 44
EQ EQ
" 6"
/2
1' - 4"
/4
DRAWING ILLUSTRATES JAMB CONDITION
AT HEIGHT OF MANUFACTURED STONE
7 1/4"
/4
1 1/2"
7 1/4"
7 1/4"
/8
/8
/8
/8
3 3/4"
8 3/4"
M O
S E
L E
Y A
R C
H
IT
E C
T S
.C O
M
PROJECT NO:
DATE:
N
O R
F O
L K
S T
R E
E T
R
IC
H
M O
N D
V
A
P H
O N
E
-7
X
-5
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
/2
/2
:3 :4
P
M
DETAILS
H . R
. T . J
R . A
R N G R
EA
D
IN
ES
S C
EN
TE
R (T
A R C ) V
IS
IT
O R S C
EN
TE
R
S . G
E O
R G
E M
A S
O N
D R
, A R
L
IN
G T
O N
, V A
A2.4
V A
F M
P N
9-
594303
MAY 27 2020
3" = 1'-0"A2.2 A2.4
DETAIL4
APPLIES TO DRAWINGS A2.2 - A2.4 & A5.1.2 - A5.1.4
1 SELF ADHERED FLEXIBLE FLASHING MEMBRANE
2 CFSF-S. REFER TO STRUCTURAL
3 ALUMINUM RAINLEADER
4 VERTICALLY ORIENTED GROUND FACE CMU
5 GROUND FACE CMU
6 EIFS REVEAL
7 ALUMINUM 3/8" x 1/2" TRIM
8 EIFS. COLOR SHALL MATCH TARC BUILDING ONE
9 ALUMINUM CONDUCTOR HEAD
10 PREMANUFACTURED COPING
11 WET SEAL MCM PANEL JOINTS
12 FLASHING WITH DRIP EDGE SET INTO CONTINUOUS BED OF SEALANT. DRIP EDGE WITH
HEMMED EDGES, FORM DRIP (TURN DOWN IMMEDIATELY AT FACE OF WALL - DO NOT
PROVIDE A FLAT SURFACE BEFORE FORMING DRIP)
13 5/8" EXTERIOR WALL SHEATHING
14 MECHANICAL CEILING ATTACHMENT FASTENED DIRECTLY TO STUDS
15 2" WATER DRAINABLE EIFS SYSTEM
16 1/2" RECESSED BOND BREAK FILLER AND SEALANT. ANGLE TOP OF SEALANT SO THAT IT
SHEDS WATER AWAY FROM THE BUILDING.
17 DO NOT PROVIDE METAL THROUGH WALL FLASHING AT THIS WATERTABLE. MAINTAIN
CONTINUOUS DRAINAGE LAYER BETWEEN THE STACKED WALL TYPES
18 TERMINATE EIFS AT EDGE OF MCM. PROVIDE ROOF MEMBRANE AT THE REMAINDER OF
THE COLUMN FACE
19 FLUID APPLIED AWV BARRIER
20 WELDED SCUPPER SLEEVE
21 ICE/WATER SHIELD
22 MCM PANEL. IF THE PANEL LENGTH AT THE INSIDE EDGE OF THE CANOPY PARAPET
NEAR THE TRANSITION TO THE ROOFING MEMBRANE IS LESS THAN THE APPROVED
MANUFACTURER'S MINIMUM, RAISE THE HEIGHT OF THE CANOPY PARAPET TO MEET
THE MINIMUM REQUIREMENT AT NO ADDITIONAL COST TO THE OWNER
23 DAMPPROOFING. START AT BASE OF WALL FLASHING OR TOP OF EXTERIOR SLAB,
WHICHEVER IS HIGHER, AND EXTEND DOWN TO TOP OF FOOTING
24 SLOPE TOP OF WD BLOCKING
25 BACKER ROD AND SEALANT
26 PROVIDE 1" ISOLATION JOINT AROUND ENTIRE BEAM PENETRATION. FILL WITH
COMPRESSIBLE SEALANT
27 SOLID SURFACE WINDOW STOOL
28 TAPER TOP OF RIGID BOARD CAVITY-WALL INSULATION
29 GYP BD SILL
30 ALUMINUM GUTTER
31 1/2" ROOF SHEATHING
32 1 5/8" CFSF-NS
33 PREMANUFACTURED FASCIA
34 REFER TO STRUCTURAL FOR LOCATION OF SLAB DEPRESSIONS. COORDINATE WITH
MANUFACTURER'S RECOMMENDATIONS FOR DEPRESSION DEPTH
35 FASTEN ROOFING MEMBRANE TO A LAYER OF GYP SHEATHING AND BLOCKING AT THE
EDGE OF THE COLUMN. GYP SHEATHING SHALL RUN FROM THE TOP OF THE WOOD
BLOCKING TO THE UNDERSIDE OF THE DECK. WRAP FLASHING OVER TOP OF ROOFING
MEMBRANE
36 PROVIDE L5x3-1/2x5/16 "(LLV) SILL ANGLE W/ 5/8" DIAM SCREW ANCHORS (4" EMBED) AT
EACH END AND AT 16" OC
37 NOTCH EIFS TO ALLOW FOR ROOF FASTENER, METAL COUNTER FLASHING, AND
SEALANT
38 NOTCH EIFS TO PROVIDE CONTINUOUS TERM BAR AND SEALANT
39 WEEP INSERT
40 MANUFACTURED STONE VENEER. PROVIDE PREFORMED CORNERS AT ALL CORNERS
41 3" x 2" 16 GAGE PLATE CLOSURE ANGLE
42 3" x 3" 16 GAGE PLATE CLOSURE ANGLE
43 2" x 2" 16 GAGE PLATE CLOSURE ANGLE
44 1 3/4" x 1 3/4" 16 GAGE PLATE CLOSURE ANGLE
45 PROVIDE THREE CONTINUOUS ROWS OF SEALANT. AT LEAST ONE ROW MUST BE AT THE
INTERIOR CONCRETE, AND AT LEAST ONE ROW MUST BE AT THE EXTERIOR CONCRETE
46 STOREFRONT SILL FLASHING WITH END DAMS
47 PROVIDE CONTINUOUS STRIP OF RIP-RAP TO MATCH STONE AT NEARBY GARDEN
DRAINS, REFER TO CIVIL DOCUMENTS. PROVIDE FOR THE FULL LENGTH OF THE
ADJACENT ARCHITECTURAL PRECAST SHAPE, CONTAINED BY METAL LANDSCAPE
EDGING
48 DOOR THRESHOLD
49 COUNTERTOP. REFER TO A8.1
50 EIFS EXPANSION JOINT
51 PROVIDE 1/2" RIGID INSULATION BETWEEN SLABS. WHERE POSSIBLE, EXTEND 2" BELOW
THE BOTTOM OF THE INTERIOR SLAB
52 SS DEAL TRAY WITH SLIDING TRANSACTION TRAY
53 WEATHERSTRIPPING
54 AUTO DOOR ACTUATOR. MOUNT CENTER OF PLATE 48" AFF
55 TRANSITION STRIP
56 PROVIDE 3 1/2" x 7 LEGS (LLV) WITH 5/8" DIAMETER SCREW ANCHORS (4" EMBED) AT
EACH END AND AT 16" OC
57 STEP FLASHING AS REQUIRED. MAINTAIN MINIMUM 6" BETWEEN FLASHING AND FINISHED
GRADE OR PAVEMENT
58 TWO CONTINUOUS ROWS OF SEALANT ATOP DRIP EDGE AND BELOW FLEXIBLE
FLASHING MEMBRANE
59 FINISH FLOORING. REFER TO A3.0
60 WALL BASE. REFER TO A3.0
61 COPING TO WALL COUNTERFLASHING, SET INTO TWO CONTINUOUS ROWS OF SEALANT
62 CONTINUOUS SLAB AT OPENING
63 ROOFING MEMBRANE
64 MAINTAIN CONTINUOUS INSULATION
3" = 1'-0"A2.2 A2.4
DETAIL3
1 1/2" = 1'-0"A2.1 A2.4
DETAIL12
1 1/2" = 1'-0"A2.1 A2.4
DETAIL11
1 1/2" = 1'-0"A2.1 A2.4
PLAN DETAIL10
3" = 1'-0"A2.1 A2.4
DETAIL9
3" = 1'-0"A2.1 A2.4
DETAIL1
1 1/2" = 1'-0"A2.1 A2.4
DETAIL6
3" = 1'-0"A2.1 A2.4
DETAIL7
3" = 1'-0"A2.1 A2.4
DETAIL5
3" = 1'-0"A2.1 A2.4
DETAIL2
3" = 1'-0"A2.3 A2.4
DETAIL8
A. FINISH SCHEDULE DESCRIBES ONLY THE BASIC OR PREDOMINANT SURFACE FINISH.
B. PROVIDE SAME FINISHES AS THE ADJACENT SPACE IN ALCOVES AND CONTINUOUS
SPACES WITHOUT DESIGNATED SPACE NUMBERS.
C. DIRECTIONAL WALL FINISH INDICATORS (NORTH, EAST, SOUTH, WEST) REFER TO THE
"PLAN" NORTH ORIENTATION.
D. BULKHEADS AND SOFFITS MAY NOT BE INDICATED IN FINISH SCHEDULES. REFER TO RCP
DETAILS, AND OTHER DOCUMENTS FOR EXTENT.
E. PROVIDE CONTINUOUS SEALANT BETWEEN INTERIOR SLAB-ON-GRADE AND VERTICAL
ELEMENT WHERE JOINT IS NOT CONCEALED BY FINISH BASE OR OTHER CONSTRUCTION.
F. FINISH SELECTIONS INTENDED TO MATCH THOSE OF THE EXISTING TARC BUILDING ONE.
THEREFORE, SUBSTITUTIONS WILL NOT BE CONSIDERED.
FINISH SCHEDULE GENERAL NOTES
NOTE:
1. REFER TO DETAILS ON THIS SHEET FOR FLOOR PATTERNS.
2. REFER TO ELEVATION FOR TYPICAL WALL PATTERNS.
3. FROST DOOR 04B AND ASSOCIATED GLAZING AT STOREFRONT.
4. FROST DOOR 05A AND ASSOCIATED SIDELIGHT.
5. FROST DOOR 12A AND ASSOCIATED SIDELIGHT.
6. PAINT DOOR TRIM PTD-3.
7. REFER TO 1/A2.1 FOR GARDEN COURTYARD HARDSCAPE PLAN.
SUPERVISOR
OFFICE
ADMIN WORK
AREA
CAC OFFICE
VISITOR
CORRIDOR
SECURITY
SCREENING
VESTIBULE
IT ROOM
BREAK ROOM
ELEC/MECH
ROOM
STAFF TOILET
PUBLIC TOILET
HELP DESK
CAC
RECEPTIONIST
WAITING
ROOM
04 ADMIN
WORKSTATION
JANITORS
CLOSET
PEDESTRIAN
CHECK
WINDOW
03B
FLOOR PATTERN LEGEND
TILE-5A, REFER TO DETAIL 6/A3.0 FOR WAITING ROOM AND
VISITOR CORRIDOR TILE PATTERN
LVT-2
TILE-3
TILE-1, REFER TO DETAIL 5/A3.0 FOR TOILET ROOM TILE
PATTERN
CPT-1
CPT-2
WALK-OFF SYSTEM
Level 1 0"
Level 1 0"
Level 1 0"
EQ EQ EQ EQ
1' - 7"
A T
T H
E F
L O
O R
F U
L L T
IL
Level 1 0"
Level 1 0"
BB1 BB1
BB2BB2
BB4
BB4 BB4
BB4
EQ EQ
OFFSET TYPICAL
7 1/2"
E Q
E Q
EQ
EQ
.0
1/
TIL
E O
FFS
ET
M O
S E
L E
Y A
R C
H
IT
E C
T S
.C O
M
PROJECT NO:
DATE:
N
O R
F O
L K
S T
R E
E T
R
IC
H
M O
N D
V
A
P H
O N
E
-7
X
-5
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
/2
/2
:3 :5
P
M
FINISH SCHEDULE
AND FLOOR
PATTERN PLAN
H . R
. T . J
R . A
R N G R
EA
D
IN
ES
S C
EN
TE
R (T
A R C ) V
IS
IT
O R S C
EN
TE
R
S . G
E O
R G
E M
A S
O N
D R
, A R
L
IN
G T
O N
, V A
A3.0
V A
F M
P N
9-
594303
MAY 27 2020
FIN ISH SC H ED U LE
NUMBER NAME FLOOR BASE
WALLS
WAINSCOT MILLWORK CEILING NOTESNORTH EAST SOUTH WEST
01 VESTIBULE WALK-OFF WB-1 PTD-1A PTD-1A PTD-1A PTD-1A ACP
02 EXTERIOR GARDEN - - - - - - 7
03 SECURITY SCREENING CPT-2 WB-1 PTD-1A PTD-1A PTD-1A PTD-1A PL-1 / PL-2 ACP 1
03B PEDESTRIAN CHECK WINDOW CPT-2 WB-1 PTD-1A PTD-1A PTD-1A PTD-1A PL-1 / PL-2 ACP 1
04 WAITING ROOM TILE-5A TILE-5B PTD-1A PTD-1A PTD-1A PTD-1A GYP BD / ACP 1, 3
05 VISITOR CORRIDOR TILE-5A TILE-5B PTD-1A PTD-1A - PTD-1A GYP BD 1, 4
06 CAC RECEPTIONIST CPT-1 WB-1 PTD-1A PTD-1A PTD-1A PTD-1A PL-2 / SS-1 ACP 6
07 HELP DESK CPT-1 WB-1 PTD-1A PTD-1A WC-2 PTD-1A PL-2 / SS-1 ACP 6
08 CAC OFFICE CPT-1 WB-1 PTD-1A PTD-1A PTD-1A PTD-1A ACP
09 ADMIN WORK AREA LVT-2 WB-1 PTD-1A PTD-1A PTD-1A PTD-1A / BB ACP
10 SUPERVISOR OFFICE CPT-1 WB-1 PTD-1A PTD-1A PTD-1A PTD-1A ACP
11 JANITORS CLOSET TILE-3 TILE-2B PTD-1B PTD-1B PTD-1B PTD-1B TILE-2A @2'-6"AFF ACP
12 STAFF CORRIDOR CPT-1 WB-1 PTD-1A PTD-1A PTD-1A PTD-1A ACP 5
13 ADMIN WORKSTATION CPT-1 WB-1 - - PTD-1A PTD-1A ACP
14 IT ROOM TILE-3 WB-1 PTD-1A PTD-1A PTD-1A PTD-1A EXP-CON
15 BREAK ROOM LVT-2 WB-1 PTD-1A PTD-1A PTD-1A PTD-1A PL-2 / SS-1 ACP
16 ELEC/MECH ROOM TILE-3 WB-1 PTD-1A PTD-1A PTD-1A PTD-1A EXP-CON
17 STAFF TOILET TILE-1 TILE-1 TILE-1 TILE-1 TILE-1 TILE-1 PL-2 / SS-2 GYP BD 1, 2
18 PUBLIC TOILET TILE-1 TILE-1 TILE-1 TILE-1 TILE-1 TILE-1 PL-2 / SS-2 GYP BD 1, 2
1/4" = 1'-0"A2.1 A3.0
FIRST FLOOR - FLOOR PATTERN PLAN1
APPLIES TO THIS DRAWING
1 WALK-OFF SYSTEM
2 ALIGN
INTERIOR COLOR SCHEDULE MATERIAL SELECTIONS
ABBREVIATION DESCRIPTION MANUFACTURER SIZE STYLE / COLOR
FLOORING
CPT-1 CARPET TILE TANDUS 24" X 24" STYLE: "ALL STAR" #02931, COLOR: #17301 SKYSCRAPER WITH FLEAXAIRE CUSHION BACKING
CPT-2 CARPET TANDUS 24" x 24" STYLE: "ABRASIVE ACTION II", COLOR: WINTER GRAY 19103
LVT-2 LUXURY VINYL TILE MOHAWK 36" X 36" STYLE: "BOLD", COLOR: #925 PEWTER
TILE-1 FLOOR TILE ARCHITECTURAL CERAMICS,…