ATTACH09_WR-ALC SAFE-T-GRAM.PDF

PDF 217 KB Posted

Attached to
Robins AFB Mechanical/Electrical II IDIQ Federal contract opportunity
Solicitation number
FA850124R0001
Issued by
Department of the Air Force Materiel Command Air Force Sustainment Center

About this file

This document provides guidance for cleaning work areas at Robins Air Force Base to comply with OSHA regulations regarding lead, chromium VI, and cadmium dust. It designates several buildings and shop areas as "No Dry Sweeping" zones where dust free cleaning methods must be used due to potential exposure to heavy metal dust from industrial processes or previously contaminated parts and equipment. Approved dust free cleaning methods include HEPA-filtered vacuuming for gross contamination and wet cleaning methods such as wet wipes, mops, and electrostatic sweepers. Commercial floor scrubbers may also be used if they do not visibly cause dust to become airborne. Random inspections will be conducted by the base Safety Office to ensure compliance with this guidance. Personnel should contact their Wing Safety Office or UEC for waste disposal questions.

View the file

Other files for this federal contract opportunity

Other files attached to Robins AFB Mechanical/Electrical II IDIQ, newest first.
File Type Posted
RFI_230077.230101_Mech.Elec_FINAL_Rev01_01162024.xlsx XLSX spreadsheet
FA850124R00010001_01022024.pdf PDF
ATTACH19_AF3065_BLANK_SAMPLE.xlsx XLSX spreadsheet
ATTACH24_B670_Fire Plan.pdf PDF
ATTACH18_AF3064_BLANK_SAMPLE.xlsx XLSX spreadsheet
RFI_230077.230101_Mech.Elec_FINAL_01022024.xlsx XLSX spreadsheet
ATTACH25_B670_Drawing_Floor Plan.pdf PDF
ATTACH01_SOW_MechElec_Rev03_12292023.pdf PDF
Mech.Elec.2_site.visit.attendance_14Dec2023.pdf PDF
ATTACH19_AF3065_BLANK_SAMPLE.pdf PDF
ATTACH10_SUBMITTAL REGISTER.XLS XLS spreadsheet
ATTACH07_ICD705_Construction and Management_SCIF.PDF PDF
ATTACH04_AFMAN 31-116 Motor Vehicle Traffic Supervision.PDF PDF
ATTACH22_230101DEMO_Bid Schedule_BLANK.pdf PDF
ATTACH21_230101DEMO_SOW_07102023.pdf PDF
ATTACH12_Master Utility Outage.PDF PDF
ATTACH03_ProceduralGuide_DesignersAE_2023.PDF PDF
ATTACH01_SOW_MechElec_Rev02_08112023.pdf PDF
ATTACH18_AF3064_BLANK_SAMPLE.pdf PDF
ATTACH16_AF3000_MaterialSubmittal.PDF PDF
ATTACH15_AF2586 Flightline Driving Request.PDF PDF
ATTACH05_AFMAN 32-1084 Civil Engineering Facility Requirements.PDF PDF
ATTACH02_Robins BFS 2022.pdf PDF
FA850124R0001_FINAL_00_11092023.pdf PDF
ATTACH23_230101DEMO_SubmittalRegister.xlsx XLSX spreadsheet
ATTACH20_WD_GA20230322_07212023.pdf PDF
ATTACH17_AF3052_BLANK_SAMPLE.XLS XLS spreadsheet
ATTACH14_DD1354(BLANK)_SAMPLE.PDF PDF
ATTACH13_Form 911 DesignDiscipline Review.docx DOCX document
ATTACH11_TEMPLATE_Schedule of Values_BLANK.PDF PDF
ATTACH08_AppC_Safety_053312023.PDF PDF
ATTACH06_Asbestos Management Plan_2015.PDF PDF
Show all 32

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WR-ALC

SAFE-T-GRAM

WR-ALC SAFE-T-GRAM

11-003

SUBJECT: Update 2 Guidance for Cleaning Work Areas

ISSUE DATE: 3 January 14

In accordance with OSHA 29 CFR 1910.1025 (h)(2)(ii), 1910.1026(j)(2)(ii), and

1910.1027 (k)(5), industrial areas of any shop in buildings 44, 45, 46, 47, 48, 49 , 50, 54, 59, 81, 82, 83, 89, 91, 110, 125, 137, 140, 142, 149, 150, 158, 165, 169, 180, 189, 255, 321, 323, 350, 635, 640, 645, 670, 2316, 20031, 20036, and 20180 that have processes that are potential sources of Lead, Chromium VI, and/or Cadmium dust, or that handles parts/equipment previously exposed to this dust, are designated No Dry Sweeping areas.

In addition, adjacent areas such as break rooms, shop floor offices, PSC’s, WSSCs, restrooms, and locker rooms that may potentially be contaminated from dust that has migrated from the industrial area are also designated No Dry Sweeping areas. Any abrasive operation (sanding, grinding, buffing, cutting, trimming, grit blasting, filing, hand sanding, etc.) that may generate Lead, Chromium VI, or Cadmium dust are also designated No Dry Sweeping areas.

Compressed air and dry sweeping may be used in building 59D, the grit blast booth in building 169, building 137 bay 3 & 4, and the two grit blast booths in building 142 as long as the ventilation system is in operation and the proper PPE is used while cleaning.

Dust free cleaning methods: For gross contamination use a HEPA-filtered vacuum.

Other dust free methods include wet methods such as wet wipes, mops, and electrostatic

“swiffer-type” sweepers and are approved for cleaning contaminated surfaces.

Commercial floor scrubbers that use wet methods and do not visibly cause dust to become airborne are also approved for large floor areas.

These procedures are not applicable in administrative areas that are located outside of the production floor areas.

The WR-ALC Safety Office will conduct random visits to these areas to ensure compliance with this guidance and to assist with any questions or concerns expressed.

Additional facilities may be identified through future swipe sampling and inspections.

For additional information, contact your Wing Safety Office @ 468-1708.