Att 03 - Dental Final Drawing 3 of 6.pdf
PDF 13 MB Posted
- Solicitation number
- 36C77624R0085
About this file
This document appears to be Attachment 03 - Dental Final Drawing 3 of 6, which is related to Solicitation No. 36C77624R0085 for Project 612-164 - Dental Expansion and Relocation Northern California VAMC Located on Travis AFB, California. The solicitation is issued by the Department of Veterans Affairs Technology Acquisition Center Austin. The project involves the dental expansion and relocation at the Northern California VAMC located on Travis AFB in California. The document appears to be an architectural or engineering drawing that is part of the solicitation package. No additional details about the required products or services, response dates, award information, or other salient contract details are included in this particular attachment.
View the file
Other files
Show all 41
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C
9"
BA
4" x 25" VISION
PANEL
ED
"SO""SO" "SX" "SX" 3
/2
P
A C
K A
G E
H E
IG
H
T
LOUVER LOUVER
LOUVERALUMINUM FRAMED
GLAZING
DOOR TYPES:
INTERIOR FINISH SCHEDULE REMARKS:
1. SEE FINISH PLAN FOR FLOORING PATTERN.
2. PROVIDE CEMENTITIOUS BACKER BOARD BEHIND WALL TILE.
3. PROVIDE 3/4" FIRE TREATED AND PAINTED PLYWOOD OVER GWB ON ALL WALLS UP TO 8'-0" AFF - CUT TO FIT AROUND SWITCHES AND
OUTLETS.
4. PROVIDE GWB CEILING TRANSITIONS / SOFFITS WHERE SHOWN.
5. BOTH TYPES OF CEILING APPLY.
6. STATIC DISSIPATIVE FLOORING.
7. SEALED CONCRETE FLOOR.
8. 5/8" GWB W/ 1/16" LEAD LINING UP TO 7'-0" AFF.
RF RUBBER FLOORING
RWC IMPACT RESISTANT WALLCOVERING
(SC) SPECIAL COATING
(SP) SPECIAL FACED
ABBREVIATIONS:
AT ACOUSTICAL CEILING TILE
CPT CARPET TILE
CT CERAMIC TILE
EXP EXPOSED
GWB GYPSUM WALLBOARD
LVT LUXURY VINYL TILE
P PAINT
RB RUBBER BASE
RES RESINOUS EPOXY FLOORING
CONC CONCRETE
PT PORCELAIN TILE
LL LEAD LINED GWB
P1 (FIELD): KM541 TUFTED TAN
P2: (ACCENT) DET591 SILVER SCREEN IN RECEPTION 1000A, WAITING ROOM 1000, CONFERENCE 1038, DENTAL BAYS ON WEST SIDE OF BUILDING.
P3: (ACCENT) DE6319 GRAY FLANNEL IN ADMIN OFFICES 1030, 1032, 1034, OPEN OFFICE 1004, 1010, DENTAL BAYS ON EASE SIDE OF BUILDING P4: (ACCENT) DE6220 POROUS STONE IN LOUNGE 1036, X-RAY 1002, RECOVERY 1018, ORAL SURGERY 1014, BARIATRIC OPERATOR 1006, DENTAL BAYS ON NORTH SIDE OF BUILDING CARPET: PATCRAFT - INSTALL METHOD - ASHLAR IN COLLECTION: ISLE OF SKYE, 10456 EDINBURGH, 00525 GEARY.
RUBBER BASE: 6 INCH COVED, JOHNSONITE 32 PEBBLE
RUBBER FLOORING: NORPLAN VALUA, 6718 WALNUT
RESINOUS PANELS: 3 FORM VARIA FRAY BASALT/STRUCTURED BAMBOO / POWDER
LVT1: ARMSTRONG / TERRA / ST 300 GRATON PLUME
LVT2: ARMSTRONG COALESCE ST831 GEOME SULPHUR
LVT3: ARMSTRONG / BIOMED / BOREAL / MALMO / S282
LOCKER / TOILET FINISH, PT-1: PORCELAIN TILE, 24"x24", DALTILE, UNITY, P402 GRIGIO, MATTE FINISH FOR RESTOOM FLOOR LOCKER / TOILET FINISH, PT-2: PORCELAIN TILE, 12'x24", DALTILE, UNITY P405 ASHGREY, POLISHED FINISH FOR RESTROOM WALL, TILE TO 54" A.F.F.
LOCKER / TOILET FINISH, PTB-1: PORCELAIN TILE BASE, 12"x24", DALTILE, UNITY, P405 GRIGIO, MATTE FINISH FOR COVE BASE.
LOCKER / TOILET FINISH, GT-1: GLASS ACCENT TILE, 11.73:x11.73", DALTINE, SERENADE, F192 SURF ROCK FOR RESTROOM WALL, INSTALL ABOVE PRIMARY WALL TILE, CUT IN HALF FOR RECTANGULAR TILE, ACCENT STRIP.
SOLID SURFACE, SS1: CORIAN, CLAM SHELL
WALL PROTECTION, FRONT OF HOUSE AREAS: INPRO 0531 NATURAL MAPLE
WALL PROTECTION, BACK OF HOUSE AREAS: INPRO 0350 SHARKSIN
LAMINATE CASEWORK: WILSONART KENSINGTON MAPLE
DOORS:WITH NATURAL FINISH CLEAR MAPLE
PAINTED DOORS AND FRAMES: SEE SECTION 09 06 00
INTERIOR FINISH NOTES:
1. AUTOMATIC BI-PARTING SLIDING DOOR PACKAGE UNIT WITH BREAKOUT FEATURE . ALL HARDWARE, AUTOMATIC
DOOR OPERATOR, CONTROLS, AND DEVICES BY DOOR MANUFACTURER.
2. AUTOMATIC SWING DOOR WITH SENSOR SAFETY DEVICES AND RECESSED PUSH BUTTON MANUAL CONTROLS ON
BOTH SIDES.
3. ALL GLAZING ON DOORS SHALL BE LAMINATED SAFETY GLAZING - SEE SPECIFICATIONS FOR ADDITIONAL GLAZING
REQUIREMENTS.
4. ACCESS CONTROLLED DOOR VIA CARD READER.
5. PROVIDE EACH DOOR LEAF WITH 24" WIDE x 18" HIGH BOTTOM METAL LOUVER.
6. PROVIDE 42" WIDE x 18" HIGH LOUVER TRANSOM ABOVE DOOR.
7. IN ADDITION TO HAVING SAFETY GLAZING, VISION PANELS IN FIRE RATED DOORS SHALL BE 45 MINUTE FIRE
PROTECTION RATED.
8. LEVEL 4 DOOR AND FRAME - SEE SPEC SECTION 08 11 13 FOR DETAILED REQUIREMENTS.
9. PROVIDE 24" W x 18" H LOUVER ON EACH DOOR LEAF.
10. ACCESS CONTROLLED DOOR VIA COMBINATION LOCK.
11. DOOR AND FRAME LEAD LINING THICKNESS IS 1/16".
DOOR SCHEDULE REMARKS:
L I C
E N S E D A R C H I T EC
T
S T
A T
E O F C A L I F O
R N
I A
JO
RGE E . A L FARO
REN._______
C-22051
03/23
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h ts i n c h o n e f o o t o n e h a lf in c h o n e f o o t th re e q u a rt e rs in c h o n e f o o t o n e in c h o n e f o o t o n e a n d o n e h a lf in c h o n e f o o t o n e in c h o n e f o o t
VA FORM 08-6231
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title: Project Title: Project Number:
Building Number:
Drawing Number:Location:
Date: Checked: Drawn:
Office of Construction and Facilities Management
Dwg. of
VA MEDICAL CENTER, FAIRFIELD, CA 94535
K.F. DAVIS ENGINEERING, INC.
530 LA GONDA WAY, SUITE E,
DANVILLE, CA 94526
WWW.KFDE.US
(925) 743-8884
6/14/2023 2:04:12 PMC:\Users\ashrestha\Documents\FAIRFIELD - DENTAL - CENTRAL_V2021_FINAL_Anil.ShresthaMSEWP.rvt
RELOCATE AND EXPAND
DENTAL CLINIC TO
FAIRFIELD
A. SHRESTHA
AE500
ARCHITECTURAL SCHEDULES
J. ALFARO
612-164
A. SHRESTHA
08/10/2022
INTERIOR FINISH SCHEDULE
ROOM NUMBER ROOM NAME FLOOR BASE WAINSCOT WALLS CEILING REMARKS
1C01 CORRIDOR LVT RB --- GWB / P AT 4
1C02 CORRIDOR LVT RB --- GWB / P AT 4
1C03 CORRIDOR LVT RB --- GWB / P AT 4
1C04 CORRIDOR LVT RB --- GWB / P AT 4
1C05 CORRIDOR LVT RB --- GWB / P AT 4
1C06 CORRIDOR LVT RB --- GWB / P AT ---
1C07 CORRIDOR LVT RB --- GWB / P AT ---
1000 WAITING LVT RB --- GWB / P GWB / P 1
1000A RECEPTION CPT RB --- GWB / P AT 4
1000B TOILET PT-1 PTB-1 PT-2 +4'-6" GWB / P GWB / P 2
1000C TOILET PT-1 PTB-1 PT-2 +4'-6" GWB / P GWB / P 2
1001 OPERATORY RF RF --- GWB / P AT 4
1002 X-RAY LVT RB --- LL GWB / GWB / P AT 8
1003 OPERATORY RF RF --- GWB / P AT 4
1004 6 DENTIST CPT RB --- GWB / P AT ---
1005 OPERATORY RF RF --- GWB / P AT 4
1006 BARIATRIC OPERATORY RF RF --- GWB / P AT ---
1007 OPERATORY RF RF --- GWB / P AT 4
1008 STORAGE RF RB --- GWB / (SC) AT (SP) ---
1009 OPERATORY RF RF --- GWB / P AT 4
1010 10 DENTIST CPT RB --- GWB / P AT ---
1011 OPERATORY RF RF --- GWB / P AT 4
1012 STORAGE LVT RB --- GWB / P AT ---
1013 OPERATORY RF RF --- GWB / P AT 4
1014 ORAL SURGERY RF RF --- GWB / (SC) GWB (SC) ---
1015 OPERATORY RF RF --- GWB / P AT 4
1016 LABORATORY RES RES --- GWB / (SC) GWB (SC) ---
1017 OPERATORY RF RF --- GWB / P AT 4
1018 RECOVERY RF RF --- GWB / P AT ---
1019 OPERATORY RF RF --- GWB / P AT 4
1020 CLEAN RF WSF RWC +4' - 0" GWB / (SC) AT (SP) ---
1021 OPERATORY RF RF --- GWB / P AT 4
1022 DIRTY RF WSF RWC +4' - 0" GWB / (SC) AT (SP) ---
1023 OPERATORY RF RF --- GWB / P AT 4
1024 OIT RES RB --- GWB / P EXP 3, 6
1025 OPERATORY RF RF --- GWB / P AT ---
1026 FMS RES RB --- GWB / P AT (SP) 3, 6
1027 OPERATORY RF RF --- GWB / P AT ---
1028 HAC RES RES PT-2 +4'-6" GWB / (SC) AT (SP) ---
1029 OPERATORY RF RF --- GWB / P AT ---
1030 ADMIN CPT RB --- GWB / P AT ---
1031 OPERATORY RF RF --- GWB / P AT ---
1032 CHIEF CPT RB --- GWB / P AT ---
1033 OPERATORY RF RF --- GWB / P AT ---
1034 DIRECTOR CPT RB --- GWB / P AT ---
1035 LOCKERS PT PT --- GWB / (SC) AT ---
1035A TOILETS PT PT PT-2 +4'-6" GWB / P AT 2
1036 LOUNGE LVT RB --- GWB / P AT ---
1037 LOCKERS PT-1 PTB-1 --- GWB / (SC) AT ---
1037A TOILETS PT-1 PTB-1 PT-2 +4'-6" GWB / P AT 2
1038 CONFERENCE CPT RB --- GWB / P AT / GWB / P 5
1040 MECHANICAL RES RES --- GWB / P EXP ---
1040A E. POWER RES RES --- GWB / P EXP 6
1040B NORMAL POWER RES RES --- GWB / P EXP 6
1041 F.R. CONC --- --- GWB / P EXP 7
DOOR SCHEDULE
DOOR TAG ROOM NUMBER ROOM NAME TYPE
OPENING
(WIDTH X HEIGHT) THICKNESS
DOOR
CONSTRUCTION DOOR FINISH
FRAME
CONSTRUCTION FRAME FINISH
GLAZING
(WIDTH X HEIGHT) FIRE LABEL STC RATING
HARDWARE
GROUP REMARKS
1 1000 WAITING D 3' - 0" x 7' - 0" 1 3/4" ALUM COLOR ANOD ALUM COLOR ANOD --- --- --- 1, 3
2 1000 WAITING B 4' - 0" x 7' - 0" 1 3/4" SC WD NF HM PAINT 4" x 2' - 1" --- --- HW - SH - 3D 2, 3, 4
4 1002 X-RAY A 4' - 0" x 7' - 0" 1 3/4" LL SC WD NF LL HM PAINT --- --- HW - 4Q 11
5 1004 6 DENTIST A 3' - 6" x 7' - 0" 1 3/4" SC WD NF HM PAINT --- STC 45 HW - 4E ---
6 1C01 CORRIDOR A 3' - 6" x 7' - 0" 1 3/4" INSUL HM PAINT HM PAINT --- --- HW - SH - 12 4, 8
7 1008 STORAGE B 3' - 6" x 7' - 0" 1 3/4" SC WD NF HM PAINT 4" x 2' - 1" 45 MIN --- HW - 5B 3, 7
8 1010 10 DENTIST A 3' - 6" x 7' - 0" 1 3/4" SC WD NF HM PAINT --- STC 45 HW - 4E ---
9 1C03 CORRIDOR A 3' - 6" x 7' - 0" 1 3/4" INSUL HM PAINT HM PAINT --- --- HW - SH - 12 4, 8
10 1012 STORAGE B 4' - 0" x 7' - 0" 1 3/4" SC WD NF HM PAINT 4" x 2' - 1" 45 MIN --- HW - 5B 3, 7
11 1016 LABORATORY B 4' - 0" x 7' - 0" 1 3/4" SC WD NF HM PAINT 4" x 2' - 1" --- --- HW - 4G 3
12 1014 ORAL SURGERY A 4' - 0" x 7' - 0" 1 3/4" SC WD NF HM PAINT --- STC 45 4B ---
14 1020 CLEAN B 4' - 0" x 7' - 0" 1 3/4" SC WD NF HM PAINT 4" x 2' - 1" 45 MIN --- HW - SH - 3D 3, 4, 7
15 1022 DIRTY B 4' - 0" x 7' - 0" 1 3/4" SC WD NF HM PAINT 4" x 2' - 1" 45 MIN --- HW - SH - 3D 3, 4, 7
16 1C05 CORRIDOR B 3' - 6" x 7' - 0" 1 3/4" SC WD NF HM PAINT 4" x 2' - 1" --- --- HW - SH - 3D 3, 4
17 1024 OIT A 3' - 6" x 7' - 0" 1 3/4" SC WD NF HM PAINT --- --- HW - SH - 3D 4
18 1000A RECEPTION B 3' - 0" x 7' - 0" 1 3/4" SC WD NF HM PAINT --- --- HW - 3E 3
19 1C06 CORRIDOR B 3' - 6" x 7' - 0" 1 3/4" SC WD NF HM PAINT 4" x 2' - 1" --- --- HW - SH - 3D 3, 4
20 1000B TOILET A 4' - 0" x 7' - 0" 1 3/4" SC WD NF HM PAINT --- --- HW - 2G ---
21 1000C TOILET A 3' - 6" x 7' - 0" 1 3/4" SC WD NF HM PAINT --- --- HW - 2G ---
22 1026 FMS A 3' - 6" x 7' - 0" 1 3/4" SC WD NF HM PAINT --- --- HW - SH - 3D 4
23 1028 HAC A 3' - 6" x 7' - 0" 1 3/4" SC WD NF HM PAINT --- --- HW - 5D ---
24 1030 ADMIN B 3' - 0" x 7' - 0" 1 3/4" SC WD NF HM PAINT --- STC 45 HW - 3E 3
25 1032 CHIEF B 3' - 0" x 7' - 0" 1 3/4" SC WD NF HM PAINT --- STC 45 HW - 3G 3
26 1034 DIRECTOR B 3' - 0" x 7' - 0" 1 3/4" SC WD NF HM PAINT --- STC 45 HW - 3G 3
27 1035 LOCKERS A 3' - 0" x 7' - 0" 1 3/4" SC WD NF HM PAINT --- --- HW - SH - 3C 10
28 1035A TOILETS A 3' - 0" x 7' - 0" 1 3/4" SC WD NF HM PAINT --- --- HW - 2 ---
29 1036 LOUNGE B 3' - 6" x 7' - 0" 1 3/4" SC WD NF HM PAINT 4" x 2' - 1" --- STC 45 HW - SH - 3C 3, 10
30 1037 LOCKERS A 3' - 0" x 7' - 0" 1 3/4" SC WD NF HM PAINT --- --- HW - SH - 3C 10
31 1037A TOILETS A 3' - 0" x 7' - 0" 1 3/4" SC WD NF HM PAINT --- --- HW - 2 ---
32 1038 CONFERENCE B 3' - 6" x 7' - 0" 1 3/4" SC WD NF HM PAINT 4" x 2' - 1" HW-4J 3
33 1C07 CORRIDOR A 3' - 6" x 7' - 0" 1 3/4" INSUL HM PAINT HM PAINT --- --- HW - SH - 12 4, 8
34 1040 MECHANICAL C 6' - 0" x 7' - 0" 1 3/4" INSUL HM PAINT HM PAINT --- --- HW - E8 5, 8, 9
35 1040 MECHANICAL E 3' - 6" x 9' - 0" 1 3/4" INSUL HM PAINT HM PAINT --- --- HW - SH - 12 4, 6, 8
36 1040B NORMAL POWER A 3' - 6" x 7' - 0" 1 3/4" HM PAINT HM PAINT 45 MIN --- HW - 6 ---
37 1040A E. POWER A 3' - 6" x 7' - 0" 1 3/4" HM PAINT HM PAINT 90 MIN --- HW - 6 ---
38 1041 F.R. C 6' - 0" x 7' - 0" 1 3/4" HM PAINT HM PAINT --- --- HW - E8 5, 8, 9
12' - 0" x 7' - 0" FULLY GLAZED ---
Revisions: Date:
'USG' DONN COMPRESSION POST
MODEL #
LENGTH
ALLOWABLE
COMPRESSION
POST
STRUCTURE
TOP CLIP
(MECHANICALLY
FASTENED)
SPRING CLIP
ATTACHMENT
HOLES
HANGER WIRE
HEAVY DUTY MAIN BEAM
BULB CLIP
(MECHANICALLY
FASTENED)
7'-0" TO 8'-6"VSA 84/102
4'-0" TO 7'-0"VSA 48/84
2'-6" TO 4'-0"VSA 30/48
VSA 18/30 1'-6" TO 2'-6"
10'-0" TO 12'-0"VSA 120/144
8-6" TO 10'-0"VSA 102/120
NOTE: ALTERNATE STEEL
MEMBER WITH SUFFICIENT
STRENGTH IN LIEU OF DONN
COMPRESSION ARE
ACCEPTABLE SUBJECT TO
ENGINEERING CALCULATION
DOCUMENTATION FOR USE
AS A COMPRESSION POST.
A FASTENER OR SPLAY WIRED MAYBE
INSERTED INTO THE TAB OF THE POST
AND THROUGH A CONVENIENCE HOLE IN
THE MAIN TEE BULB
HEAVY DUTY CROSS TEE (DASHED)
BRACE WIRE
2"
MAX.
2"
MAX.
COMPRESSION POST
HEAVY DUTY CROSS TEES
@ 2'-0" O.C.
10 GA. BRACE WIRES
HEAVY DUTY MAIN
BEAM @ 4'-0" O.C.
10 GA. HANGER WIRES
ANCHORED TO STRUCTURE
ABOVE, TYP. 4'-0" O.C.
(3 TIGHT WRAPS)
NOTES:
LEGEND
EXCEPT WHERE RIGID BRACES ARE USED TO LIMIT LATERAL DEFLECTION, SPRINKLER HEADS AND OTHER PENETRATIONS SHALL HAVE A 2" OVERSIZE RING, SLEEVE, OR ADAPTER THROUGH THE CEILING FINISH TO ALLOW FOR FREE MOVEMENT OF AT LEAST 1" IN ALL HORIZONTAL DIRECTIONS. ALTERNATIVELY, A SWING JOINT THAT CAN ACCOMMODATE 1" OF CEILING MOVEMENT IN ALL HORIZONTAL DIRECTIONS IS PERMITTED
TO BE PROVIDED AT THE TOP OF THE SPRINKLER EXTENSION
SEE DETAILS 4 AND 5 ON THIS SHEET. CEILING PERIMETER.
CEILING WITH AN AREA GREATER THAN 2500 SQ. FT. SHALL BE PROVIDED WITH SEISMIC SEPARATION JOINTS.
SEE DETAIL 7, 8, AND 9 ON THIS SHEET FOR ATTACHMENT DETAILS OF LIGHT FIXTURE 20 LBS OR LESS.
12 GAUGE VERT.
HANGER WIRE
LATERAL BRACING
COMPRESSION
STRUT AND BRACING
WIRES)
ATTACHMENT OF
RUNNERS TO
CLOSURE ANGLE
12'-0" MAX.
HEAVY DUTY
MAIN RUNNER
8" MAX.
TYP.
M A
X
T Y
P
M
A X
4'-0"
MAX.
6'-0"
MAX.
CROSS
RUNNER
PERIMETER
CLOSURE
ANGLE
M
A X
M
A X
10 GA. HANGER WIRE
ANCHORED TO STRUCTURE ABOVE
2"
2" MIN. PERIMETER
CLOSURE ANGLE W/ #12
SCREWS @ EA. STUD.
8" MAX.
ARMSTRONG STABILIZER BAR, OR
APPROVED EQUAL SYSTEM, TO KEEP
PERIMETER COMPONENTS FROM
SPREADING APART.
MIN. 3/4"
HEAVY DUTY CEILING RUNNERS
BRACE WIRES ANCHORED TO
STRUCTURE ABOVE
5/8" TYPE 'X' GWB SCREWED TO
SUSPENSION BRID
CAULK
HEAVY DUTY CEILING RUNNERS
10 GA. HANGER WIRES ANCHORED TO
STRUCTURE ABOVE, TYP. 4'-0" O.C.
HANGER WIRES TO BE TAUT AND TIED
BOTH ENDS (3 TIGHT WRAPS IN 3" AT
WIRE END)
STRUCTURE
10 GA. BRACE WIRES TO BE ATTACHED
AT A MAXIMUM OF 45 DEGREE TO THE
PLANE OF THE CEILING AND PARALLEL
TO THE COMPONENTS AT THE BRACING
POINT. BRACE WIRES TO BE TAUT AND
TIED BOTH ENDS (4 TIGHT
WRAPS IN 3" AT WIRE END)
1/4"ø EYE SCREW, TYP.
M A
X
5/8" TYPE 'X' GWB SCREWED
TO SUSPENSION GRID
ATTACH LIGHT FIXTURE
TO HEAVY DUTY CEILING GRID
HEAVY DUTY CEILING RUNNERS
10 GA. HANGER WIRE ANCHORED TO
STRUCTURE ABOVE
LIGHT FIXTURE, 20 LBS
OR LESS THAN
SUPPLEMENTAL 12 GA. HANGER
WIRE AT EA. CORNER OR
FIXTURE ANCHORED TO
STRUCTURE ABOVE
6" MAX.
10 GA HANGER WIRE
ANCHORED TO
STRUCTURE ABOVE
5/8" TYPE 'X' GWB SCREWED TO
HEAVY DUTY SUSPENSION GRID
SEAL ALL AROUND
AXONOMETRIC
45°
45°
RECESSED FLUORESCENT
LIGHT
FIXTURE PROVIDE POSITIVE
CONNECTION TO CEILING
GRID.
10 GA. FIXTURE SUPPORT AT 4
CORNERS OF FIXTURE. THREE
FULL WRAPS MINIMUM
NO. 10 GA. FIXTURE SUPPORT WIRE
WITHIN 3" OF EACH CORNER OF
LIGHT FIXTURE. SPLAY WIRES AS
SHOWN. FASTEN TO STRUCTURE WITH
16d RINK SHANK NAIL WITH MIN. 3
WIRE TURNS AT EACH CONNECTION
POINT.
HEAVY DUTY CROSS TEES
HEAVY DUTY MAIN RUNNERS
AXONOMETRIC
FLUORESCENT
LIGHT FIXTURE
WITH POSITIVE
THAN 50#, PROVIDE 2-#10 GA.
HANGERS CONNECTED FROM THE FIXTURE
HOUSING TO THE STRUCTURE ABOVE.
THESE WIRES MAY BE SLACK IF NOT
SUPPLEMENTAL SUPPORT WIRES
AS REQUIRED FOR INTERMEDIATE
HEAVY DUTY MAIN TEE
HEAVY DUTY CROSS TEE
WIRES AS REQUIRED.
FOR LIGHTING FIXTURES
ADDITIONAL SUPPORT
WEIGHING MORE THAN
DUTY TEES ONLY
BEING USED TO SUPPORT FIXTURE
MAX.
3"
FOR LIGHTING FIXTURES WEIGHING LESS
TO SUSPENDED
CEILING SYSTEM
RECESSED
CONNECTION
4-#10 GA. w/ 3 FULL
WRAPS TYP.
50 LBS., PROVIDE
NO. 10 GA. FIXTURE SUPPORT
WIRE WITHIN 3" OF EACH CORNER
OF LIGHT FIXTURE. SPLAY WIRES
AS SHOWN. FASTEN TO STRUCTURE
WITH 16d RINK SHANK NAIL WITH
MIN. 3 WIRE TURNS AT EACH
CONNECTION POINT.
45°
45°
A. GENERAL:
1. VERTICAL HANGERS. SUSPENSION WIRES SHALL NOT BE SMALLER THAN NO. 10 GAGE SPACED AT 4
FEET ON CENTER OR NO. 10 GAGE AT 5 FEET ON CENTER ALONG EACH MAIN RUNNER UNLESS
CALCULATIONS JUSTIFYING THE INCREASED SPACING ARE PROVIDED. EACH VERTICAL WIRE SHALL BE ATTACHED TO THE CEILING SUSPENSION MEMBER AND TO THE SUPPORT ABOVE WITH A MINIMUM OF THREE TURNS. CONNECTION DEVICES AT THE SUPPORTING CONSTRUCTION SHALL BE CAPABLE OF CARRYING NOT LESS THAN 100 POUNDS. SUSPENSION WIRES SHALL NOT HANG MORE THAN 1 IN 6 OUT-OF-PLUMB UNLESS COUNTER-SLOPING WIRES ARE PROVIDED. WIRES SHALL NOT ATTACH TO OR BEND AROUND INTERFERING MATERIAL OR EQUIPMENT. A TRAPEZE OR EQUIVALENT DEVICE SHALL BE USED WHERE OBSTRUCTIONS PRECLUDE DIRECT SUSPENSION. TRAPEZE SUSPENSIONS SHALL BE A MINIMUM OF BACK-TO-BACK 1-1/4 INCH COLD ROLLED CHANNELS FOR SPANS EXCEEDING 48 INCHES.
2. PERIMETER HANGERS. THE TERMINAL ENDS OF EACH CROSS RUNNER AND MAIN RUNNER SHALL
BE SUPPORTED INDEPENDENTLY A MAXIMUM OF 8 INCHES FROM EACH WALL OR CEILING
DISCONTINUITY WITH NO. 10 GAGE WIRE OR APPROVED WALL SUPPORT, U.O.N. MAIN TEE WITH FIRE
EXPANSION RELIEF NOTCH SHALL HAVE HANGER WIRE SUPPORT A MAXIMUM OF 3 INCHES FROM
NOTCH.
3. PERIMETER MEMBERS. UNLESS PERIMETER MEMBERS ARE A STRUCTURAL PART OF THE APPROVED SYSTEM. WALL ANGLES OR CHANNELS SHALL BE CONSIDERED AS AESTHETIC CLOSURES AND WITH NO STRUCTURAL VALUE. ENDS OF MAIN RUNNERS AND CROSS MEMBERS SHALL BE TIED TOGETHER
TO PREVENT THEIR SPREADING.
4. ATTACHMENT OF MEMBERS TO THE PERIMETER. TO FACILITATE INSTALLATION, MAIN RUNNERS MAY
BE ATTACHED TO THE PERIMETER MEMBER AT TWO ADJACENT WALLS WITH CLEARANCE BETWEEN
THE WALL AND THE RUNNERS MAINTAINED AT THE OTHER TWO WALLS OR AS OTHERWISE SHOWN
OR DESCRIBED FOR THE APPROVED SYSTEM.
B. FOR SUSPENDED CEILINGS IN SEISMIC DESIGN CATEGORY D, INSTALL IN ACCORDANCE WITH ASTM
C635, ASTM C636, C1SCA FOR SEISMIC ZONES 3-4 AS MODIFIED BY THE FOLLOWING:
1. HEAVY DUTY T-BAR GRID SYSTEM SHALL BE USED.
2. PERIMETER SUPPORTING CLOSURE ANGLE WIDTH SHALL BE 2 INCH MIN. IN EACH ORTHOGONAL DIRECTION, ONE END OF CEILING GRID SHALL BE ATTACHED TO CLOSURE ANGLE AND THE OTHER END SHALL CLEAR THE WALL BY 3/4 INCH AND REST FREE TO SLIDE ON THE CLOSURE ANGLE. PRE- APPROVED AND PRE-TESTED SYSTEMS WITH 7/8 INCH WIDE CLOSURE ANGLE MAY BE USED SUBJECT
TO REVIEW OF PRODUCT DATA AND CODE COMPLIANCE DOCUMENTATION FROM MANUFACTURER.
3. CEILING AREAS EXCEEDING 1,000 SF SHALL BE INSTALLED WITH HORIZONTAL RESTRAINTS WITH
APPROXIMATELY EQUAL TRIBUTARY AREA.
a. RIGID BRACES MAY BE USED IN LIEU OF DIAGONAL SPLAY WIRES. BRACES SHALL LIMIT LATERAL
DEFLECTION TO 1/4 INCH MAX. FOR ANTICIPATED LOADS
b. LATERAL FORCE BRACING. WHERE SUBSTANTIATING DESIGN CALCULATIONS ARE NOT PROVIDED, HORIZONTAL RESTRAINTS SHALL BE EFFECTED BY FOUR NO. 10 GAGE WIRES SECURED TO THE MAIN RUNNER WITHIN 2 INCHES OF THE CROSS RUNNER INTERSECTION AND SPLAYED 90 DEGREES FROM EACH OTHER AT AN ANGLE NOT EXCEEDING 45 DEGREES FROM THE PLANE OF THE CEILING. A STRUT
FASTENED TO THE MAIN RUNNER SHALL BE EXTENDED TO AND FASTENED TO THE STRUCTURAL
MEMBERS SUPPORTING THE ROOF OR FLOOR ABOVE. THE STRUT SHALL BE ADEQUATE TO RESIST THE VERTICAL COMPONENT INDUCED BY THE BRACING WIRES. THESE HORIZONTAL RESTRAINT POINTS SHALL BE PLACED A MAXIMUM OF 6 INCHES FROM ALL HORIZONTAL PIPING OR DUCTWORK THAT IS NOT PROVIDED WITH BRACING RESTRAINTS FOR HORIZONTAL FORCES. BRACING WIRES SHALL BE ATTACHED TO THE GRID AND TO THE STRUCTURE IN SUCH A MANNER THAT THEY CAN SUPPORT A DESIGN LOAD OF NOT LESS THAN 200 POUNDS (980 N) OR THE ACTUAL DESIGN LOAD, WHICHEVER US
GREATER WITH A SAFETY FACTOR OF 2.
4. IN ADDITION, CEILING AREAS EXCEEDING 2,500 REQUIRE A SEISMIC SEPARATION JOINT UNLESS
STRUCTURAL CALCULATIONS FROM CEILING MANUFACTURER DEMONSTRATE SYSTEM
PENETRATIONS AND CLOSURE ANGLES CAN ACCOMMODATE ANTICIPATED LATERAL DISPLACEMENT.
5. EXCEPT WHERE RIGID BRACES ARE USED, PROVIDE 2 INCH WIDE RING, SLEEVE, OR ADAPTER AT
SPRINKLER HEADS, OR OTHER PENETRATIONS TO ALLOW 1 INCH CEILING MOVEMENT IN ALL
DIRECTIONS.
6. BRACE ALL CEILING ELEVATION CHANGES.
7. SUPPORT CABLE TRAYS AND ELECTRICAL CONDUITS INDEPENDENT OF CEILING SYSTEM.
8. SUSPENDED CEILING SYSTEMS ARE SUBJECT TO SPECIAL INSPECTION.
SUSPENDED CEILING SYSTEM NOTES
1. HEAVY-DUTY CEILING SYSTEMS SHALL BE USED FOR THE SUPPORT OF LIGHTING FIXTURES.
2. ALL LIGHTING SUSPENDED FIXTURES SHALL BE POSITIVELY ATTACHED TO THE SUSPENDED CEILING SYSTEM. THE ATTACHMENT DEVICE SHALL HAVE A CAPACITY OF 100 PERCENT OF THE LIGHTING
FIXTURE WEIGHT ACTING IN ANY DIRECTION.
3. WHEN HEAVY-DUTY SYSTEMS ARE USED, SUPPLEMENTAL HANGERS ARE NOT REQUIRED IF A 48" MODULAR HANGER PATTERN IS FOLLOWED. WHEN CROSS RUNNERS ARE USED WITHOUT HANGERS TO SUPPORT LIGHTING FIXTURES, THESE CROSS RUNNERS SHALL PROVIDE THE SAME CARRYING CAPACITY AS THE
MAIN RUNNER.
4. LIGHTING FIXTURES WEIGHING LESS THAN 50 POUNDS SHALL HAVE, IN ADDITION TO THE REQUIREMENTS
OUTLINED ABOVE, TWO #10 GAGE HANGERS CONNECTED FROM THE FIXTURE HOUSING TO THE
STRUCTURE ABOVE. THESE WIRES MAY BE SLACK.
5. LIGHTING FIXTURES WEIGHING 56 POUNDS OR MORE SHALL BE SUPPORTED DIRECTLY FROM THE
STRUCTURE ABOVE BY APPROVED HANGERS.
6. PENDANT HUNG FIXTURES SHALL BE SUPPORTED DIRECTLY FROM THE STRUCTURE ABOVE WITH #9 GA.
WIRE OR APPROVED ALTERNATE WITHOUT USING THE CEILING SUSPENSION SYSTEM FOR DIRECT
SUPPORT.
7. SUSPENDED LIGHT FIXTURES- THESE ARE TYPICAL INSTALLATION NOTES. CONTRACTOR SHALL ADJUST, AS APPROPRIATE, TO MATCH SELECTED FIXTURE, STYLE AND WEIGHT. FOR ANY FIXTURES
EXCEEDING 75 LBS, CONTRACTOR SHALL RETAIN THE SERVICES OF A LICENSED STRUCTURAL ENGINEER
TO PROVIDE MOUNTING INSTRUCTIONS.
SUSPENDED LIGHTING FIXTURE NOTES
2"
8" MAX.
10 GA. HANGER WIRE
ANCHORED TO STRUCTURE
ABOVE
2" MIN. PERIMETER
CLOSURE ANGLE W/ #12
SCREWS @ EA. STUD.
ARMSTRONG STABILIZER BAR, OR
APPROVED EQUAL SYSTEM, TO
KEEP
PERIMETER COMPONENTS FROM
SPREADING APART.
HEAVY DUTY CEILING RUNNERS
BRACE WIRES ANCHORED TO
STRUCTURE ABOVE
ATTACH RUNNER TO CLOSURE
ANGLE AT ONE END
CAULK
L I C
E N S E D A R C H I T EC
T
S T
A T
E O F C A L I F O
R N
I A
JO
RGE E . A L FARO
REN._______
C-22051
03/23
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h ts i n c h o n e f o o t o n e h a lf in c h o n e f o o t th re e q u a rt e rs in c h o n e f o o t o n e in c h o n e f o o t o n e a n d o n e h a lf in c h o n e f o o t o n e in c h o n e f o o t
VA FORM 08-6231
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title: Project Title: Project Number:
Building Number:
Drawing Number:Location:
Date: Checked: Drawn:
Office of Construction and Facilities Management
Dwg. of
VA MEDICAL CENTER, FAIRFIELD, CA 94535
K.F. DAVIS ENGINEERING, INC.
530 LA GONDA WAY, SUITE E,
DANVILLE, CA 94526
WWW.KFDE.US
(925) 743-8884
6/14/2023 2:04:15 PMC:\Users\ashrestha\Documents\FAIRFIELD - DENTAL - CENTRAL_V2021_FINAL_Anil.ShresthaMSEWP.rvt
RELOCATE AND EXPAND
DENTAL CLINIC TO
FAIRFIELD
A. SHRESTHA
AE501
ARCHITECTURAL GYPSUM BOARD
CEILING DETAILS
J. ALFARO
612-164
A. SHRESTHA
08/10/2022
SCALE: NTS AE501
GWB - COMPRESSION POST DETAIL1
SCALE: NTS AE501
GWB - COMPRESSION POST ISOMETRIC2
SCALE: NTS AE501
GWB - TYPICAL CEILING FRAMING PLAN3
SCALE: NTS AE501
GWB - CEILING GRID PERIMETER 14
SCALE: NTS AE501
GWB - HANGER/BRACE WIRE ATTACHMENT6
SCALE: NTS AE501
GWB - LIGHT FIXTURE ATTACHMENT7
SCALE: NTS AE501
GWB - SUSPENDED LIGHT FIXTURE 18
SCALE: NTS AE501
GWB - SUSPENDED LIGHT FIXTURE 29
SCALE: NTS AE501
GWB - CEILING GRID PERIMETER 25
'USG' DONN COMPRESSION POST
MODEL #
LENGTH
ALLOWABLE
COMPRESSION
POST
STRUCTURE
TOP CLIP
(MECHANICALLY
FASTENED)
SPRING CLIP
ATTACHMENT
HOLES
HANGER WIRE
MAIN BEAM
BULB CLIP
(MECHANICALLY
FASTENED)
7'-0" TO 8'-6"VSA 84/102
4'-0" TO 7'-0"VSA 48/84
2'-6" TO 4'-0"VSA 30/48
VSA 18/30 1'-6" TO 2'-6"
10'-0" TO 12'-0"VSA 120/144
8-6" TO 10'-0"VSA 102/120
NOTE: ALTERNATE STEEL
MEMBER WITH SUFFICIENT
STRENGTH IN LIEU OF DONN
COMPRESSION ARE
ACCEPTABLE SUBJECT TO
ENGINEERING CALCULATION
DOCUMENTATION FOR USE
AS A COMPRESSION POST.
A FASTENER OR SPLAY WIRED MAYBE
INSERTED INTO THE TAB OF THE POST
AND THROUGH A CONVENIENCE HOLE IN
THE MAIN TEE BULB
CROSS TEE (DASHED)
BRACE WIRE
2"
MAX.
2"
MAX.
COMPRESSION POST
CROSS TEES @ 2'-0" O.C.
12 GA. BRACE WIRES
MAIN BEAM @ 4'-0" O.C.
12 GA. HANGER WIRES
ANCHORED TO STRUCTURE
ABOVE, TYP. 4'-0" O.C.
(3 TIGHT WRAPS)
NOTES:
LEGEND
EXCEPT WHERE RIGID BRACES ARE USED TO LIMIT LATERAL DEFLECTION, SPRINKLER HEADS AND OTHER PENETRATIONS SHALL HAVE A 2" OVERSIZE RING, SLEEVE, OR ADAPTER THROUGH THE CEILING TILE TO ALLOW FOR FREE MOVEMENT OF AT LEAST 1" IN ALL HORIZONTAL DIRECTIONS. ALTERNATIVELY, A SWING JOINT THAT CAN ACCOMMODATE 1" OF CEILING MOVEMENT IN ALL HORIZONTAL DIRECTIONS IS PERMITTED
TO BE PROVIDED AT THE TOP OF THE SPRINKLER EXTENSION
SEE DETAILS 4 AND 5 ON THIS SHEET. CEILING PERIMETER.
CEILING WITH AN AREA GREATER THAN 2500 SQ. FT. SHALL BE PROVIDED WITH SEISMIC SEPARATION JOINTS.
SEE DETAIL 7, 8, AND 9 ON THIS SHEET FOR ATTACHMENT DETAILS OF LIGHT FIXTURE 20 LBS OR LESS.
12 GAUGE VERT.
HANGER WIRE
LATERAL BRACING
COMPRESSION
STRUT AND BRACING
WIRES)
ATTACHMENT OF
RUNNERS TO
CLOSURE ANGLE
12'-0" MAX.
HEAVY DUTY
MAIN RUNNER
8" MAX.
TYP.
M A
X
T Y
P
M
A X
4'-0"
MAX.
6'-0"
MAX.
CROSS
RUNNER
PERIMETER
CLOSURE
ANGLE
M
A X
M
A X
12 GA. HANGER WIRE
ANCHORED TO STRUCTURE ABOVE
2"
2" MIN. PERIMETER
CLOSURE ANGLE W/ #12
SCREWS @ EA. STUD.
8" MAX.
ARMSTRONG STABILIZER BAR, OR
APPROVED EQUAL SYSTEM, TO KEEP
PERIMETER COMPONENTS FROM
SPREADING APART.
MIN. 3/4"
CEILING RUNNERS
BRACE WIRES ANCHORED TO
STRUCTURE ABOVE
ACOUSTIC CEILING PANEL
CEILING RUNNERS
12 GA. HANGER WIRES ANCHORED TO
STRUCTURE ABOVE, TYP. 4'-0" O.C.
HANGER WIRES TO BE TAUT AND TIED
BOTH ENDS (3 TIGHT WRAPS IN 3" AT
WIRE END)
ACOUSTIC CEILING PANEL
STRUCTURE
12 GA. BRACE WIRES TO BE ATTACHED
AT A MAXIMUM OF 45 DEGREE TO THE
PLANE OF THE CEILING AND PARALLEL
TO THE COMPONENTS AT THE BRACING
POINT. BRACE WIRES TO BE TAUT AND
TIED BOTH ENDS (4 TIGHT
WRAPS IN 3" AT WIRE END)
ACOUSTIC CEILING PANEL
1/4"ø EYE SCREW, TYP.
M A
X
ATTACH LIGHT FIXTURE
TO CEILING GRID
CEILING RUNNERS
12 GA. HANGER WIRE ANCHORED TO
STRUCTURE ABOVE
LIGHT FIXTURE, 20 LBS
OR LESS THAN
ACOUSTIC CEILING PANEL
SUPPLEMENTAL 12 GA. HANGER
WIRE AT EA. CORNER OR
FIXTURE ANCHORED TO
STRUCTURE ABOVE
6" MAX.
AXONOMETRIC
45°
45°
RECESSED FLUORESCENT
LIGHT
FIXTURE PROVIDE POSITIVE
CONNECTION TO CEILING
GRID.
12 GA. FIXTURE SUPPORT AT 4
CORNERS OF FIXTURE. THREE
FULL WRAPS MINIMUM
NO. 12 GA. FIXTURE SUPPORT WIRE
WITHIN 3" OF EACH CORNER OF
LIGHT FIXTURE. SPLAY WIRES AS
SHOWN. FASTEN TO STRUCTURE WITH
16d RINK SHANK NAIL WITH MIN. 3
WIRE TURNS AT EACH CONNECTION
POINT.
CROSS TEES
MAIN RUNNERS
AXONOMETRIC
FLUORESCENT
LIGHT FIXTURE
WITH POSITIVE
THAN 50#, PROVIDE 2-#12 GA.
HANGERS CONNECTED FROM THE FIXTURE
HOUSING TO THE STRUCTURE ABOVE.
THESE WIRES MAY BE SLACK IF NOT
SUPPLEMENTAL SUPPORT WIRES
AS REQUIRED FOR INTERMEDIATE
MAIN TEE
CROSS TEE
WIRES AS REQUIRED.
FOR LIGHTING FIXTURES
ADDITIONAL SUPPORT
WEIGHING MORE THAN
DUTY TEES ONLY
BEING USED TO SUPPORT FIXTURE
MAX.
3"
FOR LIGHTING FIXTURES WEIGHING LESS
TO SUSPENDED
CEILING SYSTEM
RECESSED
CONNECTION
4-#12 GA. w/ 3 FULL
WRAPS TYP.
50 LBS., PROVIDE
NO. 12 GA. FIXTURE SUPPORT
WIRE WITHIN 3" OF EACH CORNER
OF LIGHT FIXTURE. SPLAY WIRES
AS SHOWN. FASTEN TO STRUCTURE
WITH 16d RINK SHANK NAIL WITH
MIN. 3 WIRE TURNS AT EACH
CONNECTION POINT.
45°
45°
A. GENERAL:
1. VERTICAL HANGERS. SUSPENSION WIRES SHALL NOT BE SMALLER THAN NO. 12 GAGE
SPACED AT 4 FEET ON CENTER OR NO. 10 GAGE AT 5 FEET ON CENTER ALONG EACH MAIN
RUNNER UNLESS CALCULATIONS JUSTIFYING THE INCREASED SPACING ARE PROVIDED. EACH
VERTICAL WIRE SHALL BE ATTACHED TO THE CEILING SUSPENSION MEMBER AND TO THE
SUPPORT ABOVE WITH A MINIMUM OF THREE TURNS. CONNECTION DEVICES AT THE SUPPORTING
CONSTRUCTION SHALL BE CAPABLE OF CARRYING NOT LESS THAN 100 POUNDS. SUSPENSION
WIRES SHALL NOT HANG MORE THAN 1 IN 6 OUT-OF-PLUMB UNLESS COUNTER-SLOPING WIRES
ARE PROVIDED. WIRES SHALL NOT ATTACH TO OR BEND AROUND INTERFERING MATERIAL OR
EQUIPMENT. A TRAPEZE OR EQUIVALENT DEVICE SHALL BE USED WHERE OBSTRUCTIONS
PRECLUDE DIRECT SUSPENSION. TRAPEZE SUSPENSIONS SHALL BE A MINIMUM OF BACK-TO-BACK
1-1/4 INCH COLD ROLLED CHANNELS FOR SPANS EXCEEDING 48 INCHES.
2. PERIMETER HANGERS. THE TERMINAL ENDS OF EACH CROSS RUNNER AND MAIN RUNNER SHALL
BE SUPPORTED INDEPENDENTLY A MAXIMUM OF 8 INCHES FROM EACH WALL OR CEILING
DISCONTINUITY WITH NO. 12 GAGE WIRE OR APPROVED WALL SUPPORT, U.O.N. MAIN TEE WITH
FIRE EXPANSION RELIEF NOTCH SHALL HAVE HANGER WIRE SUPPORT A MAXIMUM OF 3 INCHES
FROM NOTCH.
3. PERIMETER MEMBERS. UNLESS PERIMETER MEMBERS ARE A STRUCTURAL PART OF THE
APPROVED SYSTEM. WALL ANGLES OR CHANNELS SHALL BE CONSIDERED AS AESTHETIC
CLOSURES AND WITH NO STRUCTURAL VALUE. ENDS OF MAIN RUNNERS AND CROSS MEMBERS
SHALL BE TIED TOGETHER TO PREVENT THEIR SPREADING.
4. ATTACHMENT OF MEMBERS TO THE PERIMETER. TO FACILITATE INSTALLATION, MAIN RUNNERS
MAY BE ATTACHED TO THE PERIMETER MEMBER AT TWO ADJACENT WALLS WITH CLEARANCE
BETWEEN THE WALL AND THE RUNNERS MAINTAINED AT THE OTHER TWO WALLS OR AS
OTHERWISE SHOWN OR DESCRIBED FOR THE APPROVED SYSTEM.
B. FOR SUSPENDED CEILINGS IN SEISMIC DESIGN CATEGORY D, INSTALL IN ACCORDANCE WITH
ASTM C635, ASTM C636, C1SCA FOR SEISMIC ZONES 3-4 AS MODIFIED BY THE FOLLOWING:
1. HEAVY DUTY T-BAR GRID SYSTEM SHALL BE USED.
2. PERIMETER SUPPORTING CLOSURE ANGLE WIDTH SHALL BE 2 INCH MIN. IN EACH
ORTHOGONAL DIRECTION, ONE END OF CEILING GRID SHALL BE ATTACHED TO CLOSURE ANGLE
AND THE OTHER END SHALL CLEAR THE WALL BY 3/4 INCH AND REST FREE TO SLIDE ON THE
CLOSURE ANGLE. PRE-APPROVED AND PRE-TESTED SYSTEMS WITH 7/8 INCH WIDE CLOSURE
ANGLE MAY BE USED SUBJECT TO REVIEW OF PRODUCT DATA AND CODE COMPLIANCE
DOCUMENTATION FROM MANUFACTURER.
3. CEILING AREAS EXCEEDING 1,000 SF SHALL BE INSTALLED WITH HORIZONTAL RESTRAINTS WITH
APPROXIMATELY EQUAL TRIBUTARY AREA.
a. RIGID BRACES MAY BE USED IN LIEU OF DIAGONAL SPLAY WIRES. BRACES SHALL LIMIT
LATERAL DEFLECTION TO 1/4 INCH MAX. FOR ANTICIPATED LOADS
b. LATERAL FORCE BRACING. WHERE SUBSTANTIATING DESIGN CALCULATIONS ARE NOT
PROVIDED, HORIZONTAL RESTRAINTS SHALL BE EFFECTED BY FOUR NO. 12 GAGE WIRES
SECURED TO THE MAIN RUNNER WITHIN 2 INCHES OF THE CROSS RUNNER INTERSECTION AND
SPLAYED 90 DEGREES FROM EACH OTHER AT AN ANGLE NOT EXCEEDING 45 DEGREES FROM
THE PLANE OF THE CEILING. A STRUT FASTENED TO THE MAIN RUNNER SHALL BE EXTENDED
TO AND FASTENED TO THE STRUCTURAL MEMBERS SUPPORTING THE ROOF OR FLOOR ABOVE.
THE STRUT SHALL BE ADEQUATE TO RESIST THE VERTICAL COMPONENT INDUCED BY THE
BRACING WIRES. THESE HORIZONTAL RESTRAINT POINTS SHALL BE PLACED A MAXIMUM OF 6
INCHES FROM ALL HORIZONTAL PIPING OR DUCTWORK THAT IS NOT PROVIDED WITH BRACING
RESTRAINTS FOR HORIZONTAL FORCES. BRACING WIRES SHALL BE ATTACHED TO THE GRID
AND TO THE STRUCTURE IN SUCH A MANNER THAT THEY CAN SUPPORT A DESIGN LOAD OF NOT
LESS THAN 200 POUNDS (980 N) OR THE ACTUAL DESIGN LOAD, WHICHEVER US GREATER WITH A
SAFETY FACTOR OF 2.
4. IN ADDITION, CEILING AREAS EXCEEDING 2,500 REQUIRE A SEISMIC SEPARATION JOINT
UNLESS STRUCTURAL CALCULATIONS FROM CEILING MANUFACTURER DEMONSTRATE
SYSTEM PENETRATIONS AND CLOSURE ANGLES CAN ACCOMMODATE ANTICIPATED LATERAL
DISPLACEMENT.
5. EXCEPT WHERE RIGID BRACES ARE USED, PROVIDE 2 INCH WIDE RING, SLEEVE, OR ADAPTER AT SPRINKLER HEADS, OR OTHER PENETRATIONS TO ALLOW 1 INCH CEILING MOVEMENT IN ALL
DIRECTIONS.
6. BRACE ALL CEILING ELEVATION CHANGES.
7. SUPPORT CABLE TRAYS AND ELECTRICAL CONDUITS INDEPENDENT OF CEILING SYSTEM.
8. SUSPENDED CEILING SYSTEMS ARE SUBJECT TO SPECIAL INSPECTION.
SUSPENDED CEILING SYSTEM NOTES
1. INTERMEDIATE OR HEAVY-DUTY CEILING SYSTEMS SHALL BE USED FOR THE SUPPORT OF LIGHTING
FIXTURES.
2. ALL LIGHTING SUSPENDED FIXTURES SHALL BE POSITIVELY ATTACHED TO THE SUSPENDED
CEILING SYSTEM. THE ATTACHMENT DEVICE SHALL HAVE A CAPACITY OF 100 PERCENT OF THE
LIGHTING FIXTURE WEIGHT ACTING IN ANY DIRECTION.
3. WHEN INTERMEDIATE-DUTY SYSTEMS ARE USED, SUPPLEMENTAL HANGERS SHALL BE ATTACHED TO THE GRID MEMBERS WITHIN 3 INCHES OF EACH CORNER OF EACH FIXTURE. TANDEM FIXTURES
MAY UTILIZE COMMON WIRES.
4. WHEN HEAVY-DUTY SYSTEMS ARE USED, SUPPLEMENTAL HANGERS ARE NOT REQUIRED IF A 48"
MODULAR HANGER PATTERN IS FOLLOWED. WHEN CROSS RUNNERS ARE USED WITHOUT HANGERS
TO SUPPORT LIGHTING FIXTURES, THESE CROSS RUNNERS SHALL PROVIDE THE SAME CARRYING
CAPACITY AS THE MAIN RUNNER.
5. LIGHTING FIXTURES WEIGHING LESS THAN 50 POUNDS SHALL HAVE, IN ADDITION TO THE
REQUIREMENTS OUTLINED ABOVE, TWO #12 GAGE HANGERS CONNECTED FROM THE FIXTURE
HOUSING TO THE STRUCTURE ABOVE. THESE WIRES MAY BE SLACK.
6. LIGHTING FIXTURES WEIGHING 56 POUNDS OR MORE SHALL BE SUPPORTED DIRECTLY FROM THE
STRUCTURE ABOVE BY APPROVED HANGERS.
7. PENDANT HUNG FIXTURES SHALL BE SUPPORTED DIRECTLY FROM THE STRUCTURE ABOVE WITH #9 GA. WIRE OR APPROVED ALTERNATE WITHOUT USING THE CEILING SUSPENSION SYSTEM FOR
DIRECT SUPPORT.
8. SUSPENDED LIGHT FIXTURES- THESE ARE TYPICAL INSTALLATION NOTES. CONTRACTOR SHALL ADJUST, AS APPROPRIATE, TO MATCH SELECTED FIXTURE, STYLE AND WEIGHT. FOR ANY FIXTURES
EXCEEDING 75 LBS, CONTRACTOR SHALL RETAIN THE SERVICES OF A LICENSED STRUCTURAL
ENGINEER TO PROVIDE MOUNTING INSTRUCTIONS.
SUSPENDED LIGHTING FIXTURE NOTES
2"
8" MAX.
12 GA. HANGER WIRE
ANCHORED TO STRUCTURE
ABOVE
2" MIN. PERIMETER
CLOSURE ANGLE W/ #12
SCREWS @ EA. STUD.
ARMSTRONG STABILIZER BAR, OR
APPROVED EQUAL SYSTEM, TO
KEEP
PERIMETER COMPONENTS FROM
SPREADING APART.
CEILING RUNNERS
BRACE WIRES ANCHORED TO
STRUCTURE ABOVE
ACOUSTIC CEILING PANEL
ATTACH RUNNER TO CLOSURE
ANGLE AT ONE END
L I C
E N S E D A R C H I T EC
T
S T
A T
E O F C A L I F O
R N
I A
JO
RGE E . A L FARO
REN._______
C-22051
03/23
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h ts i n c h o n e f o o t o n e h a lf in c h o n e f o o t th re e q u a rt e rs in c h o n e f o o t o n e in c h o n e f o o t o n e a n d o n e h a lf in c h o n e f o o t o n e in c h o n e f o o t
VA FORM 08-6231
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title: Project Title: Project Number:
Building Number:
Drawing Number:Location:
Date: Checked: Drawn:
Office of Construction and Facilities Management
Dwg. of
VA MEDICAL CENTER, FAIRFIELD, CA 94535
K.F. DAVIS ENGINEERING, INC.
530 LA GONDA WAY, SUITE E,
DANVILLE, CA 94526
WWW.KFDE.US
(925) 743-8884
6/14/2023 2:04:18 PMC:\Users\ashrestha\Documents\FAIRFIELD - DENTAL - CENTRAL_V2021_FINAL_Anil.ShresthaMSEWP.rvt
RELOCATE AND EXPAND
DENTAL CLINIC TO
FAIRFIELD
A. SHRESTHA
AE502
ARCHITECTURAL ACOUSTIC CEILING
DETAILS
J. ALFARO
612-164
A. SHRESTHA
08/10/2022
SCALE: NTS AE502
AT - COMPRESSION POST DETAIL1
SCALE: NTS AE502
AT - COMPRESSION POST ISOMETRIC2
SCALE: NTS AE502
AT - TYPICAL CEILING FRAMING PLAN3
SCALE: NTS AE502
AT - CEILING GRID PERIMETER 14
SCALE: NTS AE502
AT - HANGER/BRACE WIRE ATTACHMENT6
SCALE: NTS AE502
AT - LIGHT FIXTURE ATTACHMENT7
SCALE: NTS AE502
AT - SUSPENDED LIGHT FIXTURE 18
SCALE: NTS AE502
AT - SUSPENDED LIGHT FIXTURE 29
SCALE: NTS AE502
AT - CEILING GRID PERIMETER 25
G HF.6
AE503
AE503
AE503
/2
6' - 0"
12 EQ RISERS
11T @ 11" 3' - 6"
12 EQ RISERS
11T @ 11" 4' - 0 5/8"
1' - 10" 29' - 8"
5 4
/2
14' - 0" 7' - 0"
AE506
1' - 11"
1' - 0"
FINISH FLOOR
0"
ROOF DECK LOW
13' - 8"
14' - 0"
T. O. LANDING
T. O. LANDING
18' - 8"
T. O. PARAPET
(T Y
P
2 7 1
FINISH FLOOR
0"
ROOF DECK LOW
13' - 8"
18' - 8"
T. O. PARAPET
T. O. LANDING
T. O. LANDING
(T Y
P
2' - 6" 4' - 0" 1' - 10 3/8"
4 1/2"
7 5
FINISH FLOOR
0"
ROOF DECK LOW
13' - 8"
GENERAL NOTES
1. CONTRACTOR SHALL PROVIDE A CODE COMPLIANT PRE-ENGINEERED
AND PREFABRICATED METAL STAIR COMPLETE W/ ALL STAIR RUNS,
LANDINGS, RAILINGS, HANDRAILS, CONNECTION AND FINISHES TO FIT
WITHIN THE SPACE PROVIDED.
2. PREFABRICATED STAIR COMPONENTS SHALL BE BASED ON STAIRWELL
FIELD MEASUREMENTS TO AVOID ANY CONFLICTS WITH SURROUNDING
CONSTRUCTION.
3. COORDINATE STRUCTURAL SUPPORT LOCATIONS W/ STRUCTURAL SHOP
DRAWINGS.
4. STAIR SHOP DRAWINGS SHALL BE PREPARED, SIGNED AND STAMPED BY
A LICENSED STRUCTURAL ENGINEER.
5. ALL TREADS AND LANDINGS SHALL RECEIVE SEALED CONCRETE FINISH.
6. TREADS SHALL BE CONC. FILLED METAL PAN TYPE.
7. RISERS SHALL BE CLOSED METAL TYPE.
8. ALL GUARDRAILS, METAL PAN TREADS, RISERS, AND LANDINGS SHALL BE
PRIMED AND PAINTED GALVANIZED STEEL.
9. PROVIDE EACH TREAD EDGE AND EDGE OF LANDING WITH SLIP-
RESISTANT CONTRASTING COLOR WARNING STRIPE 2" WIDE. FOR FULL
WIDTH OF STAIR.
10. ALL EXPOSED STAIR METAL SURFACES SHALL BE PAINTED - EXCEPT FOR
S.S. HANDRAILS
SHEET NOTES
1 TOP FLOOR LANDING
2 INTERMEDIATE LANDING
3 CHAIN LINK FENCE ENCLOSURE WITH LOCKING GATE.
4 PRE-FABRICTED METAL STAIR
5 STEEL GUARDRAIL 42" HIGH.
6 STEEL POST TYP.
7 EIFS
8 CONCRETE PAVING.
9 S.S. HANDRAIL WITH EXTENSIONS AT TOP AND BOTTOM LANDINGS.
NOTE: NO WIRE MESH REQUIRED IN
POURED CONCRETE PAN TREAD IF
CONCRETE HAS A MINIMUM DESIGN
STRENGTH OF 4000 PSI.
NO WIRE MESH REQUIRED IN
POURED CONCRETE LANDING IF
CONCRETE HAS A MINIMUM
DESIGN STRENGTH OF 3000 PSI.
STRIN
GER C
AN VARY IN
SECTIO
N
FORMED STEEL SHEET
TREADS AND RISERS
THICKNESS AS
REQUIRED
1-1/2" CONCRETE FILLED
STEEL PAN TREADS
1 1/2"
1 1/2"11"
1 1/2"
1"
/2
M A
X
M A
X
1/4" BOLT PLATE
1/4" CLOSURE PLATE TYP.
3/4" KWIK BOLT 4" EMBED MIN.
/2
11"
TYP.
4'-0"
1' - 4"
1'-0" 11"
M
IN
AE503
AE503
STAIR
STAIR STRINGER
RETURN
HANDRAIL TO
POST
STAIR NOSING
END POST
INTERMEDIATE RAIL
TOP RAIL
1 1/2" DIA S.S. HANDRAIL
INTERMEDIATE POST @ 4'-0" MAX.
EQUALLY SPACED BETWEEN END POSTS
M
IN
L I C
E N S E D A R C H I T EC
T
S T
A T
E O F C A L I F O
R N
I A
JO
RGE E . A L FARO
REN._______
C-22051
03/23
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h ts i n c h o n e f o o t o n e h a lf in c h o n e f o o t th re e q u a rt e rs in c h o n e f o o t o n e in c h o n e f o o t o n e a n d o n e h a lf in c h o n e f o o t o n e in c h o n e f o o t
VA FORM 08-6231
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title: Project Title: Project Number:
Building Number:
Drawing Number:Location:
Date: Checked: Drawn:
Office of Construction and Facilities Management
Dwg. of
VA MEDICAL CENTER, FAIRFIELD, CA 94535
K.F. DAVIS ENGINEERING, INC.
530 LA GONDA WAY, SUITE E,
DANVILLE, CA 94526
WWW.KFDE.US
(925) 743-8884
6/14/2023 2:04:22 PMC:\Users\ashrestha\Documents\FAIRFIELD - DENTAL - CENTRAL_V2021_FINAL_Anil.ShresthaMSEWP.rvt
RELOCATE AND EXPAND
DENTAL CLINIC TO
FAIRFIELD
A. SHRESTHA
AE503
ARCHITECTURAL EXTERIOR STAIR
DETAILS
J. ALFARO
612-164
A. SHRESTHA
08/10/2022
1/4" = 1'-0" AE503
1 EXTERIOR STAIR
1/4" = 1'-0" AE503
2 EXTERIOR STAIR - WEST ELEVATION
1/4" = 1'-0" AE503
3 EXTERIOR STAIR - NORTH ELEVATION
1/4" = 1'-0" AE503
4 EXTERIOR STAIR - SOUTH ELEVATION
NORTH
SCALE: NTS AE503
CONCRETE FILLED METAL PAN TREAD/RISER7
3" = 1'-0" AE503
6 TYPICAL STAIR FOOTING AT SLAB
SCALE: NTS AE503
STAIR GUARDRAIL5
WINDOW SCHEDULE REMARKS:
A
EXTERIOR: FIXED
THERMALLY BROKEN
I.G.U.
3'-0" x 4'-0" ANOD ALUM
DARK
BRONZE 7'-0" AFF
IG-1
B 4" ANOD ALUM
DARK
BRONZE
IG-1
WINDOW SCHEDULE
MARK TYPE
WINDOW UNIT SIZE
(W X H)
FRAME
DEPTH
FRAME
WIDTH
FRAME
MATERIAL
FRAME
FINISH
WINDOW UNIT
HEAD ELEVATION
GLAZING
TYPE
REMARKS
ABBREVIATIONS
AFF ABOVE FINISH FLOOR
ALUM ALUMINUM
1. GLAZING TYPE LG-1 CONSISTS OF 1" THICK INSULATED GLAZING
UNIT. SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
2. THERMALLY BROKEN FRAME.
3. FRAME WIDTH DIMENSION INCLUDES FIXED FRAME AND
OPERATING SASH.
4. PROVIDE ON INTERIOR SIDE OF WINDOW. CASEMENT SWINGS IN
FOR ACCESS TO INTEGRAL BLINDS.
5. PROVIDE THERMALLY BROKEN MULLION(S) SAME PROFILE AS
FRAME.
6. PROVIDE INTERIOR VERTICAL MULLIONS ALIGNED WITH EXTERIOR
MULLIONS TO CREATE SAME NUMBER OF CASEMENT PANELS AS
THE NUMBER OF INDIVIDUAL PANES OF EXTERIOR GLAZING.
7. GLAZING TYPE LG-1 CONSISTS OF 1/4" THICK CLEAR LAMINATED
AND FULLY TEMPERED GLASS. SEE SPECIFICATIONS FOR
ADDITIONAL REQUIREMENTS.
I.G.U. INSULATED GLAZING UNIT
ANOD ANODIZED
H HEIGHT
C
12'-0" x 2'-0"
LG-1
INTERIOR: CASEMENT
WINDOW WITH INTEGRAL
BLINDS
4" 3 1/2"
LG-1
EXTERIOR: FIXED
THERMALLY BROKEN
I.G.U.
INTERIOR: CASEMENT
WINDOW WITH INTEGRAL
BLINDS
EXTERIOR: FIXED
THERMALLY BROKEN
I.G.U.
6'-0" x 4'-0"
ANOD ALUM
IG-1 1, 2, 3, 5
4"
DARK
BRONZE
7'-0" AFF
12'-0" AFF
3 1/2"
3 1/2"
1, 2, 3, 5
4, 6, 7
1, 2, 3, 5
4, 6, 7
1. FOR LEAD OBSERVATION WINDOWS SEE INTERIOR ELEVATIONS AND SPECIFICATIONS
NOTE: A C
WINDOW TYPES:
W
EQ EQ
H
AE511
AE511
W
EQ EQ EQ EQ
H
B
AE511
AE511
AE511
AE511
L I C
E N S E D A R C H I T EC
T
S T
A T
E O F C A L I F O
R N
I A
JO
RGE E . A L FARO
REN._______
C-22051
03/23
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h ts i n c h o n e f o o t o n e h a lf in c h o n e f o o t th re e q u a rt e rs in c h o n e f o o t o n e in c h o n e f o o t o n e a n d o n e h a lf in c h o n e f o o t o n e in c h o n e f o o t
VA FORM 08-6231
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title: Project Title: Project Number:
Building Number:
Drawing Number:Location:
Date: Checked: Drawn:
Office of Construction and Facilities Management
Dwg. of
VA MEDICAL CENTER, FAIRFIELD, CA 94535
K.F. DAVIS ENGINEERING, INC.
530 LA GONDA WAY, SUITE E,
DANVILLE, CA 94526
WWW.KFDE.US
(925) 743-8884
6/14/2023 2:04:24 PMC:\Users\ashrestha\Documents\FAIRFIELD - DENTAL - CENTRAL_V2021_FINAL_Anil.ShresthaMSEWP.rvt
RELOCATE AND EXPAND
DENTAL CLINIC TO
FAIRFIELD
A. SHRESTHA
AE504
ARCHITECTURAL WINDOW SCHEDULE
AND DETAILS
J. ALFARO
612-164
A. SHRESTHA
08/10/2022
10' - 0"
7 7/8" 35°
RIGGING ARM /
TURNBUCKLE
(MANUFACTURER
PROVIDED)
14" x 0.125" ALUM TRIM
CHANNEL 6065-T5
EXTRUDED ALUM
6" x 0.125" OUTRIGGER @ 5'-4" O.C.
6065-T5 EXTRUDED ALUM. (H6A BY
ARCHITECTURAL LOUVERS OR
APPROVED EQUAL)
(9) 6"x0.081" AIRFOIL BLADES
6063-T5 EXTRUDED ALUM
(H6A BY ARCHITECTURAL
LOUVERS OR APPROVED EQUAL)
MFR'S MOUNTING BRACKET
(MANUFACTURER
PROVIDED) PROVIDE
BACKING PLATE (SSD)
MFR'S MOUNTING BRACKET
(MANUFACTURER
PROVIDED) PROVIDE
BACKING PLATE (SSD)
5'-0"
CAULK ALL AROUND
CABINET BOTH SIDES
X-RAY EQUIPMENT CABINET (GFGI)
WALL MOUNTED X-RAY EQUIPMENT
BOX AND SWIVEL ARM (GFGI) -
ATTACH TO METAL PLATE AS
RECOMMENDED BY MFR
10 1/2" W X 14 1/2" H X 18 GA GALV STEEL
PLATE - ATTACH TO METAL STUD W/ (6) SELF
TAPPING SS COUNTERSUNK HEAD SCREWS -
CENTER ON PARTITION AND MOUNT BOTTOM
OF PLATE 4'-0" AFF (PAINT EXPOSED
SURFACES BLACK)
DOUBLE STUD
PARTITION -
SEE FLOOR PLAN
NOTE: COORDINATE STEEL PLATE SCREW
SPACING WITH X-RAY EQUIPMENT BOX
MOUNTING TEMPLATE
ALUM COPING - LAP 2" MIN OVER EIFS
WATERPROOF MEMBRANE - WRAP ALL AROUND
BLOCKING AND LAP 2" MIN OVER EIFS
2X (ROUGH) PRESSURE TREATED WOOD
BLOCKING CUT TO FIT AND SLOPED
1-1/2" 18 GALV (G90) METAL STUDS BOTH
SIDES @ 16" O.C. - WELD TO TOP AND
BOTTOM HORIZ. TUBE STEEL
5/8" EIFS OVER 5/8" TYPE 'X' GWB SHEATHING BOTH
SIDES AND THE END OF MECHANICAL EQUIPMENT
SCREEN - ATTACH TO STUDS @6" O.C.
ANGLE BRACE (SSD)
TOP AND
BOTTOM STEEL
TUBE (SSD)
STEEL POST
(SSD)
CONT. GALV. INSECT
SCREEN - SCREW
TO BOTTOM OR EA
TRACK @ 12" O.C.
T.O.S
20' - 7"
TRIM EIFS TIGHT TO BRACE, PRODE SEALANT ALL SIDES.
8'-9"
EQ. TYP.
4"
SEAM POINT SUPPORT - TYP OF (28)
AE505
NOTE: FOR PANEL BACKLIGHTING SEE ELECTRICAL DRAWINGS
PANEL MAXIMUM WEIGHT = 350#
FOR PANEL SUSPENSION SYSTEM SEE STRUCTURAL DRAWINGS
HANGER AND BRACE LOCATION
2 in5 in 23 in
HANGER AND BRACE LOCATION
CENTERLINE OF
LIGHT FIXTURES
ABOVE
CENTERLINE OF
LIGHT FIXTURES
ABOVE
8" PERIMETER TRIM
USG "COMPASSO" OR EQUAL.
FORM "COMPASSO" TRIM TO
ALIGN WITH EDGE OF RESIN
PANEL AS SHOWN
3/4" EDGE
GYPSUM BOARD
RESIN PANEL
LIGHT FIXTURE
(SED)
SUSPENSION
RUNNER
TYPICAL
POINT
SUPPORT
AE505
/2
M
A X
G A
P
/4
M
IN
13'-0"
AE505 TYP
LIGHT FIXTURE -
TYP (SED)
ARRANGE LIGHT FIXTURE ARRAY TO
FORM AN EQUALLY SPACED
SYMMETRICAL PATTERN. SUBMIT
SHOP DRAWING FOR APPROVAL
NOTE:
6" PERIMETER TRIM
USG "COMPASSO"
OR EQUAL
3/4" EDGE
GYPSUM BOARD
SUSPENSION
RUNNER
ACOUSTIC TILE
SUSPENDED RUNNER
/2
M
A X
G A
P
/4
M
IN
CEILING GRID AND TILE MAY OVERLAP OVAL
CEILING 12" MAX BUT MUST ALLOW FOR WIRE
SUPPORT AND BRACING INSTALLATION PER
CEILING DESIGN CRITERIA SHOWN ON SHEETS
AE501 AND AE502
CAP 3-15-0029-K
VARIA ECORESIN
UNIVERSAL
ANCHORING KIT 3-15-
8000-K. INCLUDES 1/4"
FLANGE 3-15-3051
BARREL 3-15-0727
THREADED ROD SUPPORT
(MANUFACTURER PROVIDED)
/4
L I C
E N S E D A R C H I T EC
T
S T
A T
E O F C A L I F O
R N
I A
JO
RGE E . A L FARO
REN._______
C-22051
03/23
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h ts i n c h o n e f o o t o n e h a lf in c h o n e f o o t th re e q u a rt e rs in c h o n e f o o t o n e in c h o n e f o o t o n e a n d o n e h a lf in c h o n e f o o t o n e in c h o n e f o o t
VA FORM 08-6231
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title: Project Title: Project Number:
Building Number:
Drawing Number:Location:
Date: Checked: Drawn:
Office of Construction and Facilities Management
Dwg. of
VA MEDICAL CENTER, FAIRFIELD, CA 94535
K.F. DAVIS ENGINEERING, INC.
530 LA GONDA WAY, SUITE E,
DANVILLE, CA 94526
WWW.KFDE.US
(925) 743-8884
6/14/2023 2:04:26 PMC:\Users\ashrestha\Documents\FAIRFIELD - DENTAL - CENTRAL_V2021_FINAL_Anil.ShresthaMSEWP.rvt
RELOCATE AND EXPAND
DENTAL CLINIC TO
FAIRFIELD
A. SHRESTHA
AE505
ARCHITECTURAL DETAILS
J. ALFARO
612-164
A. SHRESTHA
08/10/2022
1" = 1'-0" AE505
1 SUN SHADE SECTION
12" = 1'-0" AE505
2 X-RAY UNIT SUPPORT
1/2" = 1'-0" AE505
3 EQUIPMENT SCREEN WITH EIFS FINISH
SCALE: NTS AE505
SUSPENDED BACK-LIT DECORATIVE RESIN PANEL4
SCALE: NTS AE505
DECORATIVE RESIN PANEL EDGE5
SCALE: NTS AE505
SUSPENDED OVAL GYPSUM BOARD CEILING6
1" = 1'-0" AE505
7 SUSPENDED OVAL CEILING EDGE
6" = 1'-0" AE505
8 POINT SUPPORT DETAIL
NOTE: RESIN PANEL: MANUFACTURER = 3FORM,
TYPE/STYLE = VARIA ECORESIN FRAY BASALT / STRUCTURED BAMBOO / POWDER
H S S 4X
4X 5/
H S S 4X
4X 5/16
2L6X6X5/8X3/8
5 4
0'-0"
TOC
PROVIDE STD.
PARAPET ALUM.
CAP AT LADDER
(V
IF
7" 9 1/2"
M A
X
(V
IF
MIN
7"
1' - 8 1/4"
2' - 0"
T.O. ROOFING
T.O. ROOF CURB
PREFABRICATED
ALUMINUM LADDER
WITH ROOF CURB
RETURN CROSS
OVER PLATFORM
SECTION ELEVATION
AE506
T.O. ROOFING
SIM
1" MAX
1/2" MIN.
1" MAX
1/2" MIN.
(V
IF
/8
CEILING PER PLAN
METAL STUD FRAMED SOFFIT
WITH 5/8" TYPE 'X' GWB FINISH
SHOP FABRICATED WOOD TRIM
CONSISTING OF FIRE TREATED CUT TO FIT
WOOD BLOCK FINISHED ON BOTH SIDES
AND BOTH ENDS WITH PLASTIC LAMINATED
1/2" PLYWOOD. PLASTIC LAMITATE COLOR
TO BEST MATCH MODULAR DENTAL
CONSOLE PARTITION COLOR.
MODULAR DENTAL CONSOLE PARTITION -
FIELD VERIFY PARTITION DIMENSIONS
GROUT
WATERPROOF
MEMBRANE
FLOORING
SEALANT
POLYETHYLENE
BACKER ROD
RESINOUS FLOORING
RESINOUS FLOORING
AND BASE SYSTEM
OVER WP MEMBRANE
(E) CONC. SLAB
THRESHOLD
DOOR
SEALANT AND BACKUP ROD
KEYED EDGE
SPOT WELD METAL STUD
TO BRACING - TYP
5/8" GWB ALL AROUND
STEEL BASE
WHERE EXPOSED GUSSET
PLATES OCCUR INSTALL
GWB TIGHT AGAINST PLATE
AND CAULK
1 1/2" METAL FURRING
STUDS-TYP
RESINOUS FLOORING AND
BASE SYSTEM OVER WP
MEMBRANE
(E) OR (N) GWB, CONC.,
OR PLASTER FINISH
(E) OR (N) WALL
METAL COVE STRIP
SHEET NOTES
1 2X PRESSURE TREATED WOOD BLOCK.
2 SINGLE PLY TPO ROOF MEMBRANE.
3 6" COLD ROLLED METAL STUDS.
4 5/8" TYPE "X" GLASS MAT FACED GYPSUM BOARD SHEATHING.
5 WEATHER RISISTANT BARRIER (WRB)
6 2" THICK EXTERIOR INSULATED FINISH SYSTEM (EIFS).
7 ALUMINUM J-MOLD PER SIDING MANUFACTURER.
8 STANDARD SQUARE ALUMINUM COPING
9 MANUFACTURER'S ALUMINUM COPING END COVER
10 SEALANT.
6" METAL STUDS @24" O.C.
LEAD LINED
GYPSUM BOARD
C E
IL
IN
G
REF: 2/S4.1
AE508
AE508
L E
A D
S H
IE
L
D
IN
G
STANDARD GWB
AE506 STAIR LANDING
/2
T.O. LANDING
14'-0" AFF
STAIR LANDING
L I C
E N S E D A R C H I T EC
T
S T
A T
E O F C A L I F O
R N
I A
JO
RGE E . A L FARO
REN._______
C-22051
03/23
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h ts i n c h o n e f o o t o n e h a lf in c h o n e f o o t th re e q u a rt e rs in c h o n e f o o t o n e in c h o n e f o o t o n e a n d o n e h a lf in c h o n e f o o t o n e in c h o n e f o o t
VA FORM 08-6231
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title: Project Title: Project Number:
Building Number:
Drawing Number:Location:
Date: Checked: Drawn:
Office of Construction and Facilities Management
Dwg. of
VA MEDICAL CENTER, FAIRFIELD, CA 94535
K.F. DAVIS ENGINEERING, INC.
530 LA GONDA WAY, SUITE E,
DANVILLE, CA 94526
WWW.KFDE.US
(925) 743-8884
6/14/2023 2:04:29 PMC:\Users\ashrestha\Documents\FAIRFIELD - DENTAL - CENTRAL_V2021_FINAL_Anil.ShresthaMSEWP.rvt
RELOCATE AND EXPAND
DENTAL CLINIC TO
FAIRFIELD
A. SHRESTHA
AE506
ARCHITECTURAL DETAILS
J. ALFARO
612-164
A. SHRESTHA
08/10/2022
SCALE: NTS AE506
PREFABRICATED ALUMINUM LADDER1
SCALE: NTS AE506
PARTITION DETAIL2
NOTE: FIELD VERIFY ALL DIMENSIONS
SCALE: NTS AE506
EPOXY FLOORING DRAIN ISOLATION DETAIL6
SCALE: NTS AE506
EPOXY FLOORING EDGE AT THRESHOLD5
SCALE: NTS AE506
FURRING AT BRACE3
SCALE: NTS AE506
INTEGRAL RESINOUS COVED BASE4
1/4" = 1'-0" AE506
7 INFILL ELEVATION
1" = 1'-0" AE506
8 ROOF CURB PLAN VIEW AT STAIR LANDING
1" = 1'-0" AE506
9 ROOF CURB SECTION VIEW AT STAIR LANDING
H
6.8
AE507
AE507
EQ EQ EQ EQ6 3/8" 6 3/8" 6 3/8"
22'-3"
AE510
TYP OF (3)
AE507
TYP OF (6)
FINISH FLOOR
0"
6.8
AE510
6'-6"
RUBBER BASE
S.S. CORNER BOARD EACH
END
PREFAB F.R. PLAM PANELS
PREFAB PRIVACY SCREEN RESIN PANEL
6'-0" LONG x 2'-0" HIGH
SCREWED TO TOP OF WALL
RESIN PANEL: MANUFACTURER = 3FORM,
TYPE/STYLE = GO-GO
CASTAWAY/SKYDIVE/POWDER, WITH
FOUR SIDED FRAME.
AE507
AE507
FINISH FLOOR
0"
EQ EQ
PREFABRICATED PRIVACY
SCREEN ON ALUM. FRAME
3'-6"
AFF
TOP AND BOTTOM
METAL TRACK
3 5/8" METAL STUDS
@ 16" O.C. MAX
R-11 BATT INSULATION
BETWEEN STUDS
SOLID SURFACE CAP
CUT TO FIT (FLUSH W/
BASE EDGE)
CONT. SEALANT
PREFAB 1/4" FIRE
TREATED PLAM
PANEL GLUED TO
GWB (BOTH SIDES)
5/8" TYPE 'X' GWB
(BOTH SIDES)
PONY WALL
REINFORCEMENT
(SSD)
ANCHOR BASE AND FLOOR
PER SCHEDULE
6 3/8"
6'-0"AFF
(AT PRIVACY
PARTITION)
PREFAB 1/4" FIRE
TRATED PANEL GLUED
TO GWB BOTH SIDES
SURFACE MOUNTED
S.S. WALL END
GUARD SIZE TO FIT
DBL METAL
STUD
R-11 BATT INSL
BETWEEN STUDS
5/8" TYPE 'X' GWB
BOTH SIDES
3-5/8" METAL STUDS
@ 16" O.C. MAX.
L I C
E N S E D A R C H I T EC
T
S T
A T
E O F C A L I F O
R N
I A
JO
RGE E . A L FARO
REN._______
C-22051
03/23
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h ts i n c h o n e f o o t o n e h a lf in c h o n e f o o t th re e q u a rt e rs in c h o n e f o o t o n e in c h o n e f o o t o n e a n d o n e h a lf in c h o n e f o o t o n e in c h o n e f o o t
VA FORM 08-6231
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title: Project Title: Project Number:
Building Number:
Drawing Number:Location:
Date: Checked: Drawn:
Office of Construction and Facilities Management
Dwg. of
VA MEDICAL CENTER, FAIRFIELD, CA 94535
K.F. DAVIS ENGINEERING, INC.
530 LA GONDA WAY, SUITE E,
DANVILLE, CA 94526
WWW.KFDE.US
(925) 743-8884
6/14/2023 2:04:31 PMC:\Users\ashrestha\Documents\FAIRFIELD - DENTAL - CENTRAL_V2021_FINAL_Anil.ShresthaMSEWP.rvt
RELOCATE AND EXPAND
DENTAL CLINIC TO
FAIRFIELD
A. SHRESTHA
AE507
ARCHITECTURAL DETAILS -
RECEPTION COUNTER
J. ALFARO
612-164
A. SHRESTHA
08/10/2022
1/2" = 1'-0" AE507
1 RECEPTION COUNTERS
1" = 1'-0" AE507
2 RECEPTION COUNTER SECTION
3" = 1'-0" AE507
3 LOW PARTITION SECTION
3" = 1'-0" AE507
4 RECEPTION PARTITION END DETAIL
(PRIVACY PARTITION AT KIOSK SIM.)
D
5 6 4 2 8 3
15 16 7 10 1 3 19
H
616 1 3 4 15 10 7
CG
M
5" VARIES
465 19
J
8"
1'-8"
3'-0"
1'-0"
GENERAL NOTES
1. FOR WALL TYPE CONSTRUCTION MATERIALS, GAUGES, SIZES, AND
OTHER REQUIREMENTS SEE DETAILS ON SHEETS AE301 THROUGH
AE303 AND SPECIFICATIONS. FOR ADDITIONAL PLAN DIMENSIONS SEE
SHEET AE101.
2. THE DETAILS CONTAINED ON THIS SHEET ARE REPRESENTATIVE OF
TYPICAL CONSTRUCTION FRAMING AT VARIOUS CONDITIONS.
CONTRACTOR SHALL USE BEST INDUSTRY FRAMING PRACTICES AS
SPECIFIED AND AS RECOMMENDED BY METAL STUD MANUFACTURER TO
ACHIEVE A CODE COMPLIANT INSTALLATION.
3. TYP CORNER GUARDS ARE 3"x3" U.O.N.
SHEET NOTES
1 EXTERIOR METAL STUD WALL
2 INTERIOR METAL STUD WALL
3 METAL STUD TRACK
4 STRUCTURAL COLUMN
5 STRUCTURAL BRACE
6 STRUCTURAL GUSSET PLATE
7 EIFS WALL SYSTEM OR ALUMINUM METAL PANEL PER WALL SECTIONS
ON SHEET AE301 & 302 AS APPLICABLE
8 GWB
9 CORNER GUARD
10 EXTERIOR GWB SHEATHING
11 TUBE STEEL COUMN.
12 ONE-HOUR RATED WALL ASSEMBLY
13 CUT TOP AND BOTTOM TRACK AS NECESSARY TO ALLOW FOR
STRUCTURAL STEEL COLUMN.
14 METAL STUD COLUMN FURRING.
15 VAPROR BARRIER.
16 WATER RESISTANT BARRIER.
17 LEAD LINED GWB AT X-RAY.
18 HANDRAIL/BUMPER COMBINATION
19 R-19 BATT INSULATION - TYP
20 R-11 BATT INSULATION - TYP
21 ALUMINUM METAL PANEL
D
18 8 4
2 35
CGCG
CG CG
F
2 3
CGCG
CGCG
F
J.6
2 8 43 6 5
L I C
E N S E D A R C H I T EC
T
S T
A T
E O F C A L I F O
R N
I A
JO
RGE E . A L FARO
REN._______
C-22051
03/23
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h ts i n c h o n e f o o t o n e h a lf in c h o n e f o o t th re e q u a rt e rs in c h o n e f o o t o n e in c h o n e f o o t o n e a n d o n e…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .