Atch 9 - Architectural 1 of 2.pdf
PDF 18 MB Posted
- Attached to
- Y1AZ--EHRM Infrastructure Upgrades Construction - Tomah Federal contract opportunity
- Solicitation number
- 36C77622B0031
About this file
This document outlines requirements for a federal construction contract solicitation. The solicitation number 36C77622B0031 is for infrastructure upgrades and renovations to existing spaces at the Tomah VA Medical Center campus in Wisconsin. Work includes electrical, HVAC, communication, physical security, and fiber infrastructure upgrades both within and between buildings, as well as modifications to impacted roads, walks, grading, drainage, and other utilities. Data center WAN updates and hazardous material abatement are also required. The soliciting agency is the Department of Veterans Affairs Technology Acquisition Center located in Austin, Texas.
View the file
Other files for this federal contract opportunity
Show all 42
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C141
C140
C139
C138
C140A
C112
12301
1230512307
12309
12311 12306
12304
12330
12300
12332
12328 12323
12331
12313
12312
12314
12314A
12315
12316
12319 12318 12318A
12322
12325
12326
12327
12333
12339
12341
12343
12349
12347
12348
12346
12344
12324
12334
12336
12338
12340
C142
U P
D N
U P
U P
DN
UPUP
DN
DN
3-6
3-6
3-6
12335A
TELECOM
12335
HAC
CONSTRUCTION PROJECT ACTIVITY TYPE - D
INFECTION CONTROL RISK GROUP - GROUP 1 : LOW RISK
CONTROL PROCEDURE CLASS - III
INFECTION CONTROL RISK ASSESSMENT (ICRA) BY
PROJECT AREA USE AND PHASE
CONSTRUCTION INFECTION CONTROL RISK ASSESSMENT (ICRA)
TYPE A
TYPE B
TYPE C
TYPE D
INSPECTIONS AND NON-INVASIVE ACTIVITIES. INCLUDES, BUT NOT
LIMITED TO, REMOVAL OF CEILING TILES FOR VISUAL INSPECTION
LIMITED TO 1 TILE PER 50 SQUARE FEET, PAINTING BUT NOT SANDING
WALL COVERING, ELECTRICAL TRIM WORK, MINOR PLUMBING, AND
ACTIVITIES WHICH DO NOT GENERATE DUST OR REQUIRE CUTTING OF
WALLS OR ACCESS TO CEILINGS OTHER THAN FOR VISUAL INSPECTION.
SMALL SCALE, SHORT DURATION ACTIVITIES WHICH CREATE MINIMAL
DUST. INCLUDES, BUT IS NOT LIMITED TO, INSTALLATION OF TELEPHONE
AND COMPUTER CABLING, ACCESS TO CHASE SPACES, CUTTING OF
WALLS OR CEILING WHERE DUST MIGRATION CAN BE CONTROLLED.
FLOOR COVERING REMOVAL (WITHOUT SANDING OR GRINDING).
ANY WORK THAT GENERATES A MODERATE TO HIGH LEVEL OF DUST OR
REQUIRES DEMOLITION OR REMOVAL OF ANY FIXED BUILDING
COMPONENTS OR ASSEMBLIES. INCLUDES, BUT IS NOT LIMITED TO,
SANDING OF WALL FOR PAINTING OR WALLCOVERING, REMOVAL OF
FLOOR COVERINGS, CEILING TILES AND CASEWORK, NEW WALL
CONSTRUCTION, MINOR DUCTWORK OR ELECTRICAL WORK ABOVE
CEILINGS, MAJOR CABLING ACTIVITIES, AND ANY ACTIVITY WHICH
CANNOT BE COMPLETED WITHIN A SINGLE WORK SHIFT. FLOOR
COVERING REMOVAL (WITH SANDING OR GRINDING).
MAJOR DEMOLITION AND CONSTRUCTION PROJECTS. INCLUDES, BUT IS
NOT LIMITED TO, ACTIVITIES WHICH REQUIRE CONSECUTIVE WORK
SHIFTS, REQUIRE HEAVY DEMOLITION OR REMOVAL OF A COMPLETE
CEILING SYSTEM, FLOORING AND NEW CONSTRUCTION.
GROUP 1
LOW RISK
• MECHANICAL SPACES: AREAS NOT DIRECTLY ADJACENT TO PATIENT
CARE, INCLUDING INTERSTITIAL SPACES.
• ENGINEERING OR EMS OFFICE/WORK AREAS
• OFFICE AREAS: AREAS NOT ATTACHED TO/ADJOINING PATIENT CARE
AREAS, NOT USED FOR PATIENT INTERVIEWS, EVALUATIONS OR
EXAMINATIONS.
• PUBLIC CORRIDORS: SPACES NOT ON OR DIRECTLY ATTACHED TO
PATIENT UNITS OR TREATMENT LOCATIONS.
GROUP 2
MEDIUM
RISK
• OUTPATIENT AREAS:
1. PRIMARY CARE OR SPECIALTY CARE CLINIC AREAS
2. BEHAVIORAL/MENTAL HEALTH AREAS
3. EXTENDED CARE / REHAB CLINIC AREAS
4. COMMUNITY BASED OUT PATIENT CLINICS (CBOC’S)
GROUP 3
HIGH RISK
• IN-PATIENT UNITS:
1. INCLUDING, BUT NOT LIMITED TO: EMERGENCY DEPT.; NURSING
UNITS; RADIOLOGY/MRI/CT/ULTRASOUND; NUCLEAR MEDICINE;
CAFETERIA/KITCHEN/CANTEEN; LABORATORIES; RADIATION /
ONCOLOGY; DIALYSIS
GROUP 4
HIGHEST
RISK
• ICU/SICU
• OR/PACU/ENDOSCOPY
• GI
• STERILE PROCESSING SERVICES (SPS)
• PHARMACY
• CATH LAB
CLASS
I
KEEP AREAS FREE OF DEBRIS, TRASH
EXECUTE WORK TO MINIMIZE OF DUST MIGRATION (E.G. WET MOPPING, HEPA VACUUM)
IMMEDIATELY REPLACE ANY CEILING TILE DISPLACED FOR VISUAL INSPECTION
(INVOLVING MINOR DEMOLITION IN MAINTENANCE OR REMODELING.)
CLASS
II
SAME AS CLASS I PLUS:
1. ESTABLISH MATERIAL AND DEBRIS ROUTE USING NON-PATIENT/VISITOR PATHWAY
2. WATER MIST WORK SURFACE TO CONTROL DUST WHILE CUTTING OR DRILLING.
3. BLOCK OFF AND SEAL AIR VENTS
4. SEAL UNUSED DOORS WITH PLASTIC SHEATHING AND DUCT TAPE.
5. CREATE BARRIERS AS DEFINED BY INFECTION PREVENTION
6. CONTAIN CONSTRUCTION WASTE BEFORE TRANSPORT IN TIGHTLY COVERED CONTAINER; TAPE COVERING UNLESS SOLID LID.
7. WET MOP AND/OR VACUUM WITH HEPA FILTERED VACUUM BEFORE LEAVING WORK AREA.
8. PLACE STICKY MAT AT ALL WORK AREA ENTRANCES AND EXITS.
9. REMOVE OR ISOLATE HVAC SYSTEM IN CONSTRUCTION AREA
CLASS
III
SAME AS CLASS I AND II PLUS:
1. ISOLATE HVAC SYSTEM IN CONSTRUCTION AREA TO PREVENT DUCT SYSTEM CONTAMINATION
2. COMPLETE CRITICAL BARRIERS (I.E. SHEETROCK, PLYWOOD, PLASTIC) AT ALL CONSTRUCTION ENTRIES AND EXITS; MONITOR FOR SEAL AND TAKE IMMEDIATE
CORRECTIVE ACTION AS NEEDED
3. MAINTAIN AND MONITOR NEGATIVE AIR PRESSURE WITHIN CONSTRUCTION SITE UTILIZING HEPA EQUIPPED AIR FILTRATION UNITS.
4. REMOVE OR ISOLATE HVAC SYSTEMS IN AREA WHERE WORK IS BEING PERFORMED.
5. CHECK AND REPLACE AIR FILTERS AS NEEDED REGULARLY
6. DO NOT REMOVE BARRIERS FROM WORK SITE UNTIL PROJECT IS COMPLETE & HAS BEEN THOROUGHLY CLEANED; REMOVE BARRIERS CAREFULLY TO MINIMIZE
SPREADING DUST. DEBRIS.
7. VACUUM WORK WITH HEPA FILTERED VACUUM.
8. WET MOP AREA WITH CLEANER/DISINFECTANT.
9. MITIGATE VIBRATION AND NOISE TO LOWEST IMPACT WHERE POSSIBLE.
10. DISPLAY ICRA AT SITE
11. SEAL HOLES, PIPES, CONDUITS AND PUNCTURES.
CLASS
IV
SAME AS CLASS I, II AND III PLUS:
1. INSPECT ADJACENT AREAS FOR DUST MIGRATION; TAKE IMMEDIATE CORRECTIVE AS NEEDED
2. USE HEPA VACUUM IN AREA PRIOR TO START OF CONSTRUCTION
3. CONSTRUCT ANTE ROOM; ALL PERSONNEL MUST ENTER THROUGH IT TO BE VACUUMED USING HEPA VACUUM BEFORE LEAVING OR TO DON/DOFF PPE
INFECTION CONTROL &
CONSTRUCTION BARRIER
GENERAL NOTES
1. SEE SPEC SECTION 01 35 26 SAFETY REQUIREMENTS FOR ADDITIONAL
INFORMATION
2. THE INTENT OF INFECTION CONTROL ISOLATION IS TO CONTAIN DUST AND
PARTICULATE MATTER TO THE CONSTRUCTION AREA. CONSTRUCTION AREA
PERIMETER NEEDS TO BE SEALED COMPLETELY WITH SHEET PLASTIC AS
SPECIFIED AND DUCT TAPE DURING OPERATIONS, WHERE PERMITTED BY CLASS.
ICRA - CONSTRUCTION BARRIER TO BE PROVIDED AS SPECIFIED AND LISTED IN
ICRA CLASS.
3. PROVIDE NEGATIVE PRESSURE MONITORS DURING CONSTRUCTION OPERATIONS
AS SPECIFIED. MONITOR TO MEASURE PRESSURE DIFFERENTIAL BETWEEN
CONSTRUCTION AREA AND ADJACENT CORRIDOR OR ROOM AS DIRECTED BY VA.
4. AS CONSTRUCTION PROGRESSES, FROM TYPE D TO TYPE C AND THEREON,
PROVIDE A REQUEST VIA "INFECTION CONTROL CONSTRUCTION PERMIT" TO THE
VA INFECTION CONTROL NURSE. UPON AUTHORIZATION, PROCEED TO NEXT TYPE
OF CONSTRUCTION. PROVIDE AT LEAST TEN (10) WORKING DAYS NOTICE FOR
EACH PERMIT.
5. CONSTRUCT ICRA (INFECTION CONTROL) CONSTRUCTION BARRIER(S) FROM
FLOOR TO DECK/FLOOR ABOVE.
6. CONTROL BARRIERS ARE TO BE INSTALLED AND REMOVED ONLY BEFORE 7:00 AM
AND AFTER 8:00 PM OR DIRECTED BY COR
7. DURING CONSTRUCTION OPERATIONS IN EACH ENCLOSED AREA PROVIDE
NEGATIVE PRESSURE MONITORS, MINIMUM (1) ONE IN AREAS LESS THAN 1000 SF,
(2) TWO MINIMUM IN AREAS BETWEEN 1000 SF AND 5000 SF, AND (3) THREE FOR
AREAS BETWEEN 5000 SF AND 10000 SF.
8. LIFE SAFETY EGRESS IS TO BE MAINTAINED AT ALL TIMES.
9. THE CONTRACTOR SHALL PROVIDE ENOUGH NEGATIVE AIR MACHINES TO
COMPLETELY EXCHANGE THE REGULATED AREA AIR VOLUME (4) FOUR ACTUAL
TIMES PER HOUR. THE COMPETENT PERSON SHALL DETERMINE THE NUMBER OF
UNITS NEEDED FOR EACH REGULATED AREA BY DIVIDING THE CUBIC FEET IN THE
REGULATED AREA BY (15) FIFTEEN AND THEN DIVIDING THAT RESULT BY THE
ACTUAL CUBIC FEET PER MINUTE (CFM) FOR EACH UNIT TO DETERMINE THE
NUMBER OF UNITS NEEDED TO EFFECT (4) FOUR AIR CHANGES PER HOUR.
PROVIDE A STANDBY UNIT IN THE EVENT OF MACHINE FAILURE AND/OR
EMERGENCY IN AN ADJACENT AREA.
10. PRIOR TO ANY REMOVAL OF SMOKE BARRIER FIRE RATED PARTITIONS,
CONSTRUCT NEW SMOKE BARRIER/APPROPRIATE FIRE RATED PARTITIONS PER
PLANS OR CONSTRUCT INFECTION CONTROL BARRIER TO ACT AS SMOKE
BARRIER.
CONSTRUCTION PHASING
GENERAL NOTES
1. THE WORK UNDER THIS CONTRACT SHALL BE DIVIDED INTO PHASES. A PHASE
CAN INVOLVE MULTIPLE LOCATION AREAS. SEE SPECIFICATIONS SECTION 01 00 00
1.6.G PHASING.
2. THE GENERAL CONTRACTOR SHALL COORDINATE ALL PHASING AND SEQUENCING
WITH ALL TRADES AND THE OWNER. THE GENERAL CONTRACTOR SHALL PROVIDE
A DETAILED WRITTEN NARRATIVE TO OUTLINE CONSTRUCTION PHASING AND
SEQUENCE PLANS, VALIDATING AND ELABORATING ON THIS PHASING
DESCRIPTION.
3. THE GENERAL CONTRACTOR SHALL COOPERATE FULLY WITH THE OWNER SO
WORK MAY BE CARRIED OUT SMOOTHLY, WITHOUT INTERFERING WITH OR
DELAYING WORK UNDER THIS CONTRACT, OR OTHER CONTRACTS ON THE
PROJECT SITE OR WORK BY OWNER.
4. THE GENERAL CONTRACTOR'S CONSTRUCTION SCHEDULE SHALL INDICATE THE
SEQUENCE, COMMENCEMENT AND COMPLETION DATES, OWNER INSPECTION AND
APPROVAL DATES AND MOVE-OUT AND MOVE-IN DATES OF OWNER'S PERSONNEL
FOR ALL PHASES OF THE WORK.
5. THE GENERAL CONTRACTOR SHALL PERFORM THE WORK IN EACH PHASE IN THE
SEQUENCE SHOWN ON THE PHASING PLAN DRAWING(S) AND CONSTRUCTION
PHASING DESCRIPTION.
6. THE GENERAL CONTRACTOR MUST COMPLETE ALL WORK IN EACH PHASE WITH
THE VA INSPECTING AND ACCEPTING THE WORK PRIOR TO VA OCCUPANCY AND
THE CONTRACTOR PROCEEDING TO THE NEXT SCHEDULED PHASE. UPON
COMPLETION OF A PARTICULAR PHASE, THE ENTIRE AREA COVERED BY THAT
PHASE CAN BE OCCUPIED BY THE VA PERSONNEL WITH ALL SYSTEMS
FUNCTIONING PROPERLY.
7. BEFORE COMMENCING WORK ON EACH SUCCESSIVE PHASE, THE GENERAL
CONTRACTOR SHALL SUBMIT AN UPDATED COPY OF THE SCHEDULE.
8. ANY DUST PARTITIONS OR IRA - CONSTRUCTION BARRIERS CONSTRUCTED BY
THE CONTRACTOR PRIOR TO THE START OF DEMOLITION MUST REMAIN IN PLACE
UNTIL THE COMPLETION OF THAT PHASE OR SUBSEQUENT PHASE WHERE
REQUIRED.
9. THE CONTRACTOR SHALL PERFORM ALL WORK ADJACENT TO VA OCCUPIED
AREAS IN SUCH A MANNER TO ENSURE THE CONTINUOUS AND UNINTERRUPTED
USE OF ALL OCCUPIED AREAS, INCLUDING THE APPLICABLE MECHANICAL AND
ELECTRICAL SYSTEMS SERVING THESE AREAS.
10. FOR ADDITIONAL NOTES AND INFORMATION REFER TO INFECTION CONTROL
DRAWING(S) AND DEMOLITION PLANS.
11. ANY INFORMATION REGARDING SEQUENCING PROVIDED IN THE DOCUMENTS IS
FOR ARCHITECT-OWNER PLANNING PURPOSES ONLY.
12. THE CONTRACTOR DURING CONSTRUCTION SHALL MAINTAIN REQUIRED MEANS
OF EGRESS THROUGHOUT ALL PHASING.
13. THE CONTRACTOR SHALL PLAN FOR A MINIMUM OF 4 WEEKS' TIME BETWEEN
PHASES TO ALLOW THE VA TO OCCUPY THE NEWLY ACCEPTED SPACE AND
VACATE THE FOLLOW-ON PHASES. THE VA WILL ACCELERATE THIS TIME WHEN
POSSIBLE AND WILL NOTIFY THE CONTRACTOR IF THIS OCCURS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES Project :
B
IM
/2
V
A T o m a h
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-7
.B
.A
R
.r v t
/7
/2
:2
:3
A
M
B23-GC111
FIRST LEVEL INFECTION
CONTROL & PHASING PLAN
EHRM INFRASTRUCTURE
UPGRADES
TOMAH, WI
676-21-700
B23
2/11/22 GJB GJB
16477
1/8" = 1'-0"
FIRST LEVEL ICRA, CONSTRUCTION BARRIER & PHASING PLAN
NOTE:
• PROVIDE 1 HOUR FIRE RATED, STARC SYSTEMS FIREBLOCK WALL
PANELS OR APPROVED EQUAL FOR ALL ICRA/CONSTRUCTION
BARRIERS AND MODIFY SPRINKLER HEADS TO BE UPTURNED AND
EXTENDED TO 18" OF STRUCTURE.
• MOBILE ICRA CONTAINMENT SYSTEMS WILL NEED TO BE USED IN
AREAS OF WORK THAT ARE OUTSIDE OF THE INDICATED ICRA /
CONSTRUCION BARRIER LOCAIONS. SEE MEPT DRAWINGS FOR
ADDITIONAL AREAS OF WORK.
ICRA / CONSTRUCTION BARRIER
LOCATION
Revisions: Date:
C141
C140
C139
C138
C140A
C112
12301
1230512307
12309
12311 12306
12304
12330
12300
12332
12328 12323
12331
12313
12312
12314
12314A
12315
12316
12319 12318 12318A
12322
12325
12326
12327
12333
12339
12341
12343
12349
12347
12348
12346
12344
12324
12334
12336
12338
12340
C142
U P
D N
U P
U P
DN
UPUP
DN
DN
12335A
12335
3-6
3-6
3-6
C139
B23-AE111-01
B23-AE111-01
B23-AE111-01
SEE SHEET GI003 FOR GENERAL NOTES AND SYMBOLS
PANEL PREFIXES
AL- ALUMINUM
CG- COILING GRILLE
CS- COILING SLATS
HM- HOLLOW METAL
OS- OVERHEAD SECTIONAL
RD3- REVOLVING DOOR 3 PANEL
RD4- REVOLVING DOOR 4 PANEL
VL- VERTICAL LIFT
WD- WOOD
AG ALL GLASS
BF BIFOLD
BFGBIFOLD GLASS
D DUTCH
DG DUTCH GLASS
DSDUTCH W/SHELF
FFLUSH
G2GLASS 2 LIGHT
G3GLASS 3 LIGHT
GFGLASS FULL
GH GLASS HALF
LF LOUVER FULL
LGHLOUVER GLASS HALF
LH LOUVER HALF
HM-GF
FRAME PREFIXES
0 FRAMED-CASED OPENING
1 DOOR ONLY
2 SIDELIGHT(S) 1 SIDE
3 SIDELIGHT(S) 1 SIDE W/HORIZONTAL
4 SIDELIGHT(S) BOTH SIDES
5 SIDELIGHT(S) BOTH SIDES W/HORIZONTAL
6 DOOR W/TRANSOM
7 DOOR W/TRANSOM W/SIDELIGHT(S) 1 SIDE
8 TRANSOM W/SIDELIGHT(S) 1 SIDE W/HORIZONTAL
9 TRANSOM W/SIDELIGHT(S) BOTH SIDES
10 TRANSOM W/SIDELIGHT(S) BOTH SIDES W/HORIZONTAL
11 FULL WIDTH TRANSOM W/SIDELIGHT(S) 1 SIDE
1X1 1 LIGHT WIDE AND 1 LIGHT HIGH
2X2 2 LIGHTS WIDE AND 2 LIGHTS HIGH
3X3 3 LIGHTS WIDE AND 3 LIGHTS HIGH
(NOTE: OTHER COMBINATIONS POSSIBLE)
OX FIXED PANEL, ACTIVE PANEL
OXO FIXED PANEL, ACTIVE PANEL, FIXED PANEL
OXX FIXED, ACTIVE, ACTIVE
OXXO FIXED, ACTIVE, ACTIVE, FIXED
OXXXXO FIXED, ACTIVE, ACTIVE, ACTIVE, ACTIVE, FIXED
HMS-2
LNV LOUVER NARROW VISION
NVNARROW VISION
NV2 NARROW VISION 2 LIGHT
NV3 NARROW VISION 3 LIGHT
NVCNARROW VISION CENTERED
RP2 RAISED PANEL 2 PANEL
RP4 RAISED PANEL 4 PANEL
RP6 RAISED PANEL 6 PANEL
RP8 RAISED PANEL 8 PANEL
VVISION
W WINDOWS (1 ROW)
WT WINDOWS THROUGHOUT
DOOR PANEL NAMING
DOOR FRAME NAMING NOTE: ACTUAL FRAMES MAY VARY FROM DESCRIPTIONS
BELOW, REFER TO FRAME TYPE ELEVATIONS
NOTE: ACTUAL PANELS MAY VARY FROM DESCRIPTIONS
BELOW, REFER TO PANEL TYPE ELEVATIONS
PANEL SUFFIXES
AL- ALUMINUM
AL-BL- ALUMINUM BORROWED LIGHT
AL-SL- ALUMINUM SLIDING
ALR- ALUMINUM REVOLVING
CW## CURTAINWALL
HMM- HOLLOW METAL MASONRY
HMM-BL- HMM BORROWED LIGHT
HMM-DE- HMM DOUBLE EGRESS
HMS- HOLLOW METAL STUD
HMS-BL- HMS BORROWED LIGHT
HMS-DE- HMS DOUBLE EGRESS
OC- OVERHEAD COILING
OS- OVERHEAD SECTIONAL
VL- VERTICAL LIFT
WD- WOOD
WD-BL- WOOD BORROWED LIGHT
WDP- WOOD POCKET
FRAME SUFFIXES
FINISHED
FLOOR
HM-F
WD-F
WIDTH
OPENING
O P
E N
IN
G
H E
IG
H
T
FINISHED
FLOOR
HMS-1
O P
E N
IN
G
H E
IG
H
T
WIDTH
OPENING
LIFE SAFETY SYMBOLS
SMOKE TIGHT
ASSEMBLY
1 HOUR FIRE
BARRIER
2 HOUR FIRE
BARRIER
3 HOUR FIRE
BARRIER
1 HOUR FIRE &
SMOKE BARRIER
2 HOUR FIRE &
SMOKE BARRIER
3 HOUR FIRE &
SMOKE BARRIER
FIRE
EXTINGUISHER
FE
FIRE
EXTINGUISHER
CABINET
FEC
LIMITS OF
CONSTRUCTION
NOTE: NOT ALL SYMBOLS MY BE USED ON EACH PLAN
12335A
TELECOM12335
HAC
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES Project :
B
IM
/2
V
A T o m a h
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-7
.B
.A
R
.r v t
/7
/2
:2
:4
A
M
B23-AE111
FIRST LEVEL FLOOR OVERALL &
ENLARGED LIFE SAFETY PLAN
EHRM INFRASTRUCTURE
UPGRADES
TOMAH, WI
676-21-700
B23
2/11/22 GJB GJB
16477
1/8" = 1'-0"
FIRST LEVEL FLOOR PLAN
0 8' 16'4'
OPENING SCHEDULE
ASSOCIATED ROOMS OPENING PANEL INFORMATION FRAME INFORMATION
H D
W G
R O
U P
F
IR
E L
A B
E L
(M
IN
G A
S K
E T
E
LE
C T
R
IC
A L
S L
A B
E L
COMMENTSFROM ROOM NAME TO ROOM NAME NUMBER WIDTH HEIGHT
PANEL
TYPE
2ND
PANEL
TYPE
PANEL
GLAZING FRAME TYPE
FRAME
GLAZING
HAC 12335 3'-0" 7'-0" WD-F NONE HMS-1 NONE HW-5
TELECOM 12335A 3'-0" 7'-0" WD-F NONE HMS-1 NONE HW-3.
45 Y Y Y
TYPES - PANELS TYPES - FRAMES
1/4" = 1'-0"2
ENLARGED LIFE SAFETY PLAN - PARTIAL FIRST LEVEL
C139 12333
12335A
12335C139 12333
3D 3 D
A
LI
G N
DE1
DE5
DE1 DE2
DE4
REMOVE METAL CAGE
AND ALL ASSOCIATED
HARDWARE
DE10
REMOVE FIRE HOSE CABINET AND
TRIM. SEE MECHANICAL FOR
ADDITIONAL INFORMATION.
DE2
DE5
DE5
DE5
DE3
DE5
DEMOLITION PLAN KEYED NOTES
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
DE1
REMOVE VCT FLOOR FINISH AND VINYL BASE IN ITS ENTIRETY. PATCH &
PREP FLOOR FOR SCHEDULED FINISH. SEE SPECIFICATION SECTION 09 05
16 SUBSURFACE PREPARATION FOR FLOOR FINISHES
DE2
REMOVE ACT CEILING IN ITS ENTIRETY. INCLUDING ALL CEILING MOUNTED
EQUIPMENT & MECHANICAL & ELECTRICAL ITEMS. SEE MECHANICAL /
ELECTRICAL.
DE3
REMOVE GYP BD ON ONE SIDE OF PARTITION AS REQUIRED FOR
MECHANICAL, PLUMBING OR ELECTRICAL WORK. SEE PLANS AND
MECHANICAL / ELECTRICAL PLANS FOR ADDITIONAL INFORMATION
DE4
CUT OPENING IN PARTITION AS REQUIRED FOR INSTALLATION OF DOOR
AND FRAME AS SCHEDULED. SEE PLAN
DE5
REMOVE PORTION OF CEILING AS REQUIRED FOR WORK IN THIS AREA. SEE
PLANS FOR ADDITIONAL INFORMATION.
DE6
REMOVE PLUMBING FIXTURE AND ALL ASSOCIATED PIPING. -SEE MEP
DRAWINGS FOR ADDITIONAL INFORMATION
DE7
REMOVE BASE CABINETS, UPPER CABINETS, TALL CABINETS AND/ OR
COUNTERTOP AND SUPPORT BRACKETS AS REQUIRED
DE8
REMOVE PORTION OF PARTITION AS REQUIRED. SEE FLOOR PLAN AND
MEP FOR ADDITIONAL INFORMATION.
DE9
REMOVE PORTION OF RAILING AND / OR CRASH RAIL AS REQUIRED. SEE
FINISH PLAN FOR ADDITIONAL INFORMATION
DE10
REMOVE EXISTING ROOM IDENTIFICATION SIGN AND SALVAGE FOR
REINSATLLATION.
DE11
REMOVE PREMANUFACTURED WALK IN REFRIGERATOR SYSTEM IN ITS
ENTIRETY. SEE MEP PLANS FOR ADDITIONAL INFORMATION.
DE12
REMOVE CERAMIC TILE FLOORING. PATCH & PREP FLOOR FOR SCHEDULED
FINISH. SEE SPECIFICATION SECTION 09 05 16 SUBSURFACE PREPARATION
FOR FLOOR FINISHES.
DE13
SAW CUT PLASTER AND HOLLOW BUILDING TILE PARTITION FLOOR TO
CEILING AND REMOVE AS REQUIRED. SEE FLOOR PLAN FOR ADDITIONAL
INFORMATION.
DE14
REMOVE CARPET FLOORING AND BASE AND VCT FLOORING (2 LAYERS) IN
ITS ENTIRETY. PATCH & PREP FLOOR FOR SCHEDULED FINISH. SEE
SPECIFICATION SECTION 09 05 16 SUBSURFACE PREPARATION FOR FLOOR
FINISHES
DE15
REMOVE SUSPENDED LATH AND PLASTER CEILING IN ITS ENTIRETY.
INCLUDING ALL CEILING MOUNTED EQUIPMENT & MECHANICAL &
ELECTRICAL ITEMS. SEE MECHANICAL / ELECTRICAL.
DE16 REMOVE INTERIOR WINDOW SYSTEM AND TRIM IN ITS ENTIRETY.
DE17
REMOVE SHEET FLOORING FINISH AND INTEGRAL COVE BASE IN ITS
ENTIRETY. PATCH & PREP FLOOR FOR SCHEDULED FINISH. SEE
SPECIFICATION SECTION 09 05 16 SUBSURFACE PREPARATION FOR FLOOR
FINISHES
DE18
REMOVE WALL COVERING IN ITS ENTIRETY. REMOVE CARPET BASE AND
SALVAGE FOR REINSTALLATION. PATCH AND PREP FOR NEW FINISHES.
DE19
SAWCUT TERRAZZO HORIZONTALLY AND VERTICALLY AT FLOOR TO
PARTITION TRANSITION. PATCH AND PREP FOR NEW FINISHES.
DE20 REMOVE HANDRAIL IN ITS ENTIRETY. PATCH AND PREP FOR NEW FINISHES.
DE21
CUT SHEET FLOORING AT FLOOR TO PARTITION TRANSITION AND REMOVE
INTEGRAL COVE BASE, LEAVING FLOOR IN PLACE. PATCH AND PREP FOR
NEW FINISHES. SEE FINISH PLAN FOR EXTENT OF DEMOLITION.
FLOOR PLAN KEYED NOTES
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
FL1
PATCH PARTITION, WITH MATERIALS TO MATCH EXISTING ADJACENT
SURFACES, AS REQUIRED FROM DEMOLITION. WHERE EXISTING FINISHES
ARE DISTURBED PAINT TO MATCH ADJACENT FINISH, PAINT ENTIRE
PARTITION WHERE PATCHING OCCURS.
FL2
PROVIDE PLYWOOD 3 SIDES OF ROOM. SEE TYPICAL ELEVATIONS SHEET
AE211
FL3
PROVIDE METAL STUDS, AS REQUIRED AND GYP BD BOTH SIDES OF
PARTITION, ABOVE REMOVED CEILING TO UNDERSIDE OF DECK ABOVE.
WHERE PATCHING IS VISIBLE IN ROOM, PAINT TO MATCH ADJACENT FINISH,
PAINT ENTIRE PARTITION WHERE PATCHING OCCURS.
FL4
PATCH PARTITION, WITH MATERIALS TO MATCH EXISTING ADJACENT
SURFACES, AS REQUIRED FROM REMOVAL OF MECHANICAL, ELECTRICAL,
PLUMBING AND/ OR FIRE PROTECTION ITEMS. WHERE EXISTING FINISHES
ARE DISTURBED PAINT TO MATCH ADJACENT FINISH, PAINT ENTIRE
PARTITION WHERE PATCHING OCCURS. SEE MEP DRAWINGS FOR
ADDITIONAL INFORMATION
FL5
INFILL OPENING. PATCH ADJACENT SURFACES WITH MATERIALS TO MATCH
EXISTING AS REQUIRED FROM DEMOLITION. WHERE EXISTING FINISHES
ARE DISTURBED PAINT TO MATCH ADJACENT FINISH, PAINT ENTIRE
PARTITION WHERE PATCHING OCCURS. BOTH SIDES.
FL6
PROVIDE BLAST RESISTANT FILM APPLIED TO THE INSIDE FACE (ROOM
SIDE) OF GLASS. INSTALL PER MANUFACTURES INSTRUCTIONS FOR BLAST
RESISTANCE.
FL7
PATCH / MODIFY ACT CEILING TILE AND GRID AS NECESSARY,
CONTRACTOR TO PROVIDE LABOR AND MATERIALS. REPLACE ANY
BROKEN, DAMAGED OR DIRTY ACT TILES AND CEILING GRID. COORDINATE
WITH OWNER FOR ACT AND CEILING GRID TYPE. WHERE EXISTING
FINISHES ARE DISTURBED ON PAINTED SURFACES. PAINT TO MATCH
ADJACENT FINISH. PAINT ENTIRE PARTITION / SOFFIT OF EXISTING
INTERIOR SPACES WHERE PATCHING OCCURS.
FL8
PROVIDE SEMI-RECESSED RATED FIRE EXTINGUISHER CABINET. SEE
DRAWINGS AND LIFE SAFETY SYMBOLS FOR ADDITIONAL INFORMATION
FL9
PATCH METAL LATH AND PLASTER CEILING AS REQUIRED FROM
DEMOLITION. PAINT TO MATCH EXISTING FINISHES. PAINT ENTIRE CEILING
WHERE PATCHING OCCURS.
FL10
UPGRADE PARTITIONS TO 1 HOUR FIRE AND SMOKE BARRIER WHERE
INDICATED ON PLAN. PROVIDE TESTED HEAD OF PARTITION ASSEMBLY
WITH MATERIALS THAT RESIST THE PASSAGE OF SMOKE. SEAL JOINT AT
HEAD AND ALL PENETRATIONS WITH FIRE CAULK.
FL11
REINSTALL CEILING TILE AND GRID AS REQUIRED FROM DEMOLITION,
MECHANICAL, ELECTRICAL, PLUMBING, TELECOM OR FIRE PROTECTION
WORK. REPLACE ANY BROKEN, DAMAGED OR DIRTY ACT TILES AND
CEILING GRID. COORDINATE WITH OWNER FOR ACT AND CEILING GRID
TYPE. SEE MEPT FOR ADDITIONAL INFORMATION.
FL12
PROVIDE UL RATED 1 HOUR HORIZONTAL SHAFT WALL ASSEMBLY AT
CEILING TIGHT TO UNDERSIDE OF EXISTING STRUCTURE ABOVE. WHERE
EXISTING FINISHES ARE DISTURBED ON PAINTED SURFACES. PAINT TO
MATCH ADJACENT FINISH. PAINT ENTIRE PARTITION ON INTERIOR SPACES
WHERE PATCHING OCCURS. PAINT CEILING TO MATCH ADJACENT FINISH.
FINISH PLAN KEYED NOTES
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
FN1
FINISH PARTITION TO MATCH EXISTING THIS AREA, INCLUDING, BUT NOT
LIMITED TO, PAINT, WALLCOVERING, WALL PROTECTION AND WALL BASE.
CONTRACTOR TO PROVIDE LABOR AND MATERIALS
FN2 FINISH PARTITION WITH P-2 & RB-1.
FN3
MODIFY RAILING AS REQUIRED. PROVIDE RAILING SUPPORTS, ENDCAPS,
RETURNS AND ALL HARDWARE, TO MATCH EXISTING. AS REQUIRED FOR
INSTALLATION.
FN4
TELECOM ROOM TYPICAL FINISHES; SD-1 AT FLOOR, RB-1 AT BASE. ALL
WALL MOUNTED PLYWOOD TO HAVE FP-1, ALL OTHER WALL SURFACES TO
HAVE P-1. SEE 1 & 2/AE211 FOR ADDITONAL INFORMATION.
FN5
WHERE EXISTING FINISHES ARE DISTURBED BY CONSTRUCTION, FINISH TO
MATCH ADJACENT FINISHES, FINISH ENTIRE PORTION OF PARTITION AS
SHOWN WITHIN DIMENSION.
FN6
MODIFY RAILING AS REQUIRED. PROVIDE RAILING SUPPORTS, ENDCAPS,
RETURNS AND ALL HARDWARE, TO MATCH EXISTING AS REQUIRED FOR
INSTALLATION – HR-2.
FN7
MODIFY RAILING AS REQUIRED. PROVIDE RAILING SUPPORTS, ENDCAPS,
RETURNS AND ALL HARDWARE, TO MATCH EXISTING AS REQUIRED FOR
INSTALLATION – HR-3.
FN9
MODIFY RAILING AS REQUIRED. PROVIDE RAILING SUPPORTS, ENDCAPS,
RETURNS AND ALL HARDWARE, TO MATCH EXISTING AS REQUIRED FOR
INSTALLATION OR INSTALL NEW; CONTRACTOR'S CHOICE – HR-4.
FN10 FINISH PARITION WITH P-1 & REINSTALL SALVAGED CARPET BASE.
FN11 INSTALL CG-1, COLOR 0154 CLAM SHELL
FN12 SEE DETAIL _/AF601 FOR WALL FINISHES
FN13 FINISH PARTITION WITH P-6 & RB-3
FN14 FINISH PARTITION WITH P-2 & RB-3
FN15 FINISH PARTITION WITH P-2 & RB-4
FN8 INSTALL NEW HANDRAIL HR-2.
12335A
TELECOM
12335A
12335
B3bs
FL5
FL2
FL1
12335
HAC
FL5
B3bs
FL1FL8 CR
FL10
B6bs
FL11
FL11
FL12
FL4
FL4
FL11
126 SF
12335A
TELECOM
FN1
FN2
12335
HAC
IN.03-0100
FN4
IN-01.31
THIS AREA
FINISH ENTIRE PARTITION
DEMOLITION PLAN SYMBOLS
EXISTING WALL TO
REMAIN
WALL OR
PARTITION TO BE
REMOVED
EXISTING DOOR
AND FRAME TO
REMAIN
KEY NOTE
A
GRIDLINE
NOTE: NOT ALL SYMBOLS MAY BE USED ON EACH PLAN
EXISTING DOOR
AND FRAME TO BE
DEMOLISHED
DASHED LINE
INDICATES ITEM TO
BE REMOVED (UNO)
DE10
FLOOR PLAN SYMBOLS
EXISTING WALL TO
REMAIN
WALL
EXISTING DOOR
AND FRAME TO
REMAIN
DOOR
INTERIOR
BORROWED LIGHT
101B
101A
8'-0"
DIMENSION LINE,
NOMINAL
8'-0" EXTENDED
DIMENSION LINE,
NOMINAL
AE2111A
INTERIOR
ELEVATION
INDICATOR TAG
2B
AE2O1
EXTERIOR
ELEVATION
INDICATOR TAG
1A
203 EQUIPMENT TAG
100 FLOOR SPOT
ELEVATIONWALL TAG
OFFICE
ROOM NAME AND
NUMBER AE501
1A
DETAIL REFERENCE
TAG
AE2O1
EXTERIOR SECTION
REFERENCE TAG
1A
AE2O1
INTERIOR SECTION
REFERENCE TAG
1A
KEY NOTE
A
GRIDLINE
REVISION TAG
PR01
REVISION CLOUD
NOTE: NOT ALL SYMBOLS MAY BE USED ON EACH PLAN
FP10
B3
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES Project :
B
IM
/2
V
A T o m a h
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-7
.B
.A
R
.r v t
/7
/2
:2
:5
A
M
B23-AE111-01
FIRST LEVEL ENLARGED FLOOR,
RCP AND FINISH PLANS
EHRM INFRASTRUCTURE
UPGRADES
TOMAH, WI
676-21-700
B23
2/11/22 GJB GJB
16477
1/4" = 1'-0"1
ENLARGED DEMOLITION PLAN - FIRST LEVEL - ROOM 12335A
0 4' 8'2' 0 4' 8'2'0 4' 8'2'
NOTE: COORDINATE GENERAL DEMOLITION
WORK WITH ABATEMENT AND REMEDIATION WORK
1/4" = 1'-0"
ENLARGED PLAN - FIRST LEVEL - TELECOM 12335A
1/4" = 1'-0"
FINISH PLAN - FIRST LEVEL - TELECOM 12335A
OFFICE
OFFICE OFFICE
CONFERENCE
RECEPTION
AREA
OFFICE
S T
O R
A G
E
T O
IL
E
T
CORRIDOR
U T
IL
IT
Y
T O
IL
E
T
T O
IL
E
T
ROOM
4 10
WAREHOUSE/STORAGE
SECOND FLOOR LEVEL
DN
118A
TELECOM
CONSTRUCTION PROJECT ACTIVITY TYPE - D
INFECTION CONTROL RISK GROUP - GROUP 1 : LOW RISK
CONTROL PROCEDURE CLASS - III
INFECTION CONTROL RISK ASSESSMENT (ICRA) BY
PROJECT AREA USE AND PHASE
CONSTRUCTION INFECTION CONTROL RISK ASSESSMENT (ICRA)
TYPE A
TYPE B
TYPE C
TYPE D
INSPECTIONS AND NON-INVASIVE ACTIVITIES. INCLUDES, BUT NOT
LIMITED TO, REMOVAL OF CEILING TILES FOR VISUAL INSPECTION
LIMITED TO 1 TILE PER 50 SQUARE FEET, PAINTING BUT NOT SANDING
WALL COVERING, ELECTRICAL TRIM WORK, MINOR PLUMBING, AND
ACTIVITIES WHICH DO NOT GENERATE DUST OR REQUIRE CUTTING OF
WALLS OR ACCESS TO CEILINGS OTHER THAN FOR VISUAL INSPECTION.
SMALL SCALE, SHORT DURATION ACTIVITIES WHICH CREATE MINIMAL
DUST. INCLUDES, BUT IS NOT LIMITED TO, INSTALLATION OF TELEPHONE
AND COMPUTER CABLING, ACCESS TO CHASE SPACES, CUTTING OF
WALLS OR CEILING WHERE DUST MIGRATION CAN BE CONTROLLED.
FLOOR COVERING REMOVAL (WITHOUT SANDING OR GRINDING).
ANY WORK THAT GENERATES A MODERATE TO HIGH LEVEL OF DUST OR
REQUIRES DEMOLITION OR REMOVAL OF ANY FIXED BUILDING
COMPONENTS OR ASSEMBLIES. INCLUDES, BUT IS NOT LIMITED TO,
SANDING OF WALL FOR PAINTING OR WALLCOVERING, REMOVAL OF
FLOOR COVERINGS, CEILING TILES AND CASEWORK, NEW WALL
CONSTRUCTION, MINOR DUCTWORK OR ELECTRICAL WORK ABOVE
CEILINGS, MAJOR CABLING ACTIVITIES, AND ANY ACTIVITY WHICH
CANNOT BE COMPLETED WITHIN A SINGLE WORK SHIFT. FLOOR
COVERING REMOVAL (WITH SANDING OR GRINDING).
MAJOR DEMOLITION AND CONSTRUCTION PROJECTS. INCLUDES, BUT IS
NOT LIMITED TO, ACTIVITIES WHICH REQUIRE CONSECUTIVE WORK
SHIFTS, REQUIRE HEAVY DEMOLITION OR REMOVAL OF A COMPLETE
CEILING SYSTEM, FLOORING AND NEW CONSTRUCTION.
GROUP 1
LOW RISK
• MECHANICAL SPACES: AREAS NOT DIRECTLY ADJACENT TO PATIENT
CARE, INCLUDING INTERSTITIAL SPACES.
• ENGINEERING OR EMS OFFICE/WORK AREAS
• OFFICE AREAS: AREAS NOT ATTACHED TO/ADJOINING PATIENT CARE
AREAS, NOT USED FOR PATIENT INTERVIEWS, EVALUATIONS OR
EXAMINATIONS.
• PUBLIC CORRIDORS: SPACES NOT ON OR DIRECTLY ATTACHED TO
PATIENT UNITS OR TREATMENT LOCATIONS.
GROUP 2
MEDIUM
RISK
• OUTPATIENT AREAS:
1. PRIMARY CARE OR SPECIALTY CARE CLINIC AREAS
2. BEHAVIORAL/MENTAL HEALTH AREAS
3. EXTENDED CARE / REHAB CLINIC AREAS
4. COMMUNITY BASED OUT PATIENT CLINICS (CBOC’S)
GROUP 3
HIGH RISK
• IN-PATIENT UNITS:
1. INCLUDING, BUT NOT LIMITED TO: EMERGENCY DEPT.; NURSING
UNITS; RADIOLOGY/MRI/CT/ULTRASOUND; NUCLEAR MEDICINE;
CAFETERIA/KITCHEN/CANTEEN; LABORATORIES; RADIATION /
ONCOLOGY; DIALYSIS
GROUP 4
HIGHEST
RISK
• ICU/SICU
• OR/PACU/ENDOSCOPY
• GI
• STERILE PROCESSING SERVICES (SPS)
• PHARMACY
• CATH LAB
CLASS
I
KEEP AREAS FREE OF DEBRIS, TRASH
EXECUTE WORK TO MINIMIZE OF DUST MIGRATION (E.G. WET MOPPING, HEPA VACUUM)
IMMEDIATELY REPLACE ANY CEILING TILE DISPLACED FOR VISUAL INSPECTION
(INVOLVING MINOR DEMOLITION IN MAINTENANCE OR REMODELING.)
CLASS
II
SAME AS CLASS I PLUS:
1. ESTABLISH MATERIAL AND DEBRIS ROUTE USING NON-PATIENT/VISITOR PATHWAY
2. WATER MIST WORK SURFACE TO CONTROL DUST WHILE CUTTING OR DRILLING.
3. BLOCK OFF AND SEAL AIR VENTS
4. SEAL UNUSED DOORS WITH PLASTIC SHEATHING AND DUCT TAPE.
5. CREATE BARRIERS AS DEFINED BY INFECTION PREVENTION
6. CONTAIN CONSTRUCTION WASTE BEFORE TRANSPORT IN TIGHTLY COVERED CONTAINER; TAPE COVERING UNLESS SOLID LID.
7. WET MOP AND/OR VACUUM WITH HEPA FILTERED VACUUM BEFORE LEAVING WORK AREA.
8. PLACE STICKY MAT AT ALL WORK AREA ENTRANCES AND EXITS.
9. REMOVE OR ISOLATE HVAC SYSTEM IN CONSTRUCTION AREA
CLASS
III
SAME AS CLASS I AND II PLUS:
1. ISOLATE HVAC SYSTEM IN CONSTRUCTION AREA TO PREVENT DUCT SYSTEM CONTAMINATION
2. COMPLETE CRITICAL BARRIERS (I.E. SHEETROCK, PLYWOOD, PLASTIC) AT ALL CONSTRUCTION ENTRIES AND EXITS; MONITOR FOR SEAL AND TAKE IMMEDIATE
CORRECTIVE ACTION AS NEEDED
3. MAINTAIN AND MONITOR NEGATIVE AIR PRESSURE WITHIN CONSTRUCTION SITE UTILIZING HEPA EQUIPPED AIR FILTRATION UNITS.
4. REMOVE OR ISOLATE HVAC SYSTEMS IN AREA WHERE WORK IS BEING PERFORMED.
5. CHECK AND REPLACE AIR FILTERS AS NEEDED REGULARLY
6. DO NOT REMOVE BARRIERS FROM WORK SITE UNTIL PROJECT IS COMPLETE & HAS BEEN THOROUGHLY CLEANED; REMOVE BARRIERS CAREFULLY TO MINIMIZE
SPREADING DUST. DEBRIS.
7. VACUUM WORK WITH HEPA FILTERED VACUUM.
8. WET MOP AREA WITH CLEANER/DISINFECTANT.
9. MITIGATE VIBRATION AND NOISE TO LOWEST IMPACT WHERE POSSIBLE.
10. DISPLAY ICRA AT SITE
11. SEAL HOLES, PIPES, CONDUITS AND PUNCTURES.
CLASS
IV
SAME AS CLASS I, II AND III PLUS:
1. INSPECT ADJACENT AREAS FOR DUST MIGRATION; TAKE IMMEDIATE CORRECTIVE AS NEEDED
2. USE HEPA VACUUM IN AREA PRIOR TO START OF CONSTRUCTION
3. CONSTRUCT ANTE ROOM; ALL PERSONNEL MUST ENTER THROUGH IT TO BE VACUUMED USING HEPA VACUUM BEFORE LEAVING OR TO DON/DOFF PPE
INFECTION CONTROL &
CONSTRUCTION BARRIER
GENERAL NOTES
1. SEE SPEC SECTION 01 35 26 SAFETY REQUIREMENTS FOR ADDITIONAL
INFORMATION
2. THE INTENT OF INFECTION CONTROL ISOLATION IS TO CONTAIN DUST AND
PARTICULATE MATTER TO THE CONSTRUCTION AREA. CONSTRUCTION AREA
PERIMETER NEEDS TO BE SEALED COMPLETELY WITH SHEET PLASTIC AS
SPECIFIED AND DUCT TAPE DURING OPERATIONS, WHERE PERMITTED BY CLASS.
ICRA - CONSTRUCTION BARRIER TO BE PROVIDED AS SPECIFIED AND LISTED IN
ICRA CLASS.
3. PROVIDE NEGATIVE PRESSURE MONITORS DURING CONSTRUCTION OPERATIONS
AS SPECIFIED. MONITOR TO MEASURE PRESSURE DIFFERENTIAL BETWEEN
CONSTRUCTION AREA AND ADJACENT CORRIDOR OR ROOM AS DIRECTED BY VA.
4. AS CONSTRUCTION PROGRESSES, FROM TYPE D TO TYPE C AND THEREON,
PROVIDE A REQUEST VIA "INFECTION CONTROL CONSTRUCTION PERMIT" TO THE
VA INFECTION CONTROL NURSE. UPON AUTHORIZATION, PROCEED TO NEXT TYPE
OF CONSTRUCTION. PROVIDE AT LEAST TEN (10) WORKING DAYS NOTICE FOR
EACH PERMIT.
5. CONSTRUCT ICRA (INFECTION CONTROL) CONSTRUCTION BARRIER(S) FROM
FLOOR TO DECK/FLOOR ABOVE.
6. CONTROL BARRIERS ARE TO BE INSTALLED AND REMOVED ONLY BEFORE 7:00 AM
AND AFTER 8:00 PM OR DIRECTED BY COR
7. DURING CONSTRUCTION OPERATIONS IN EACH ENCLOSED AREA PROVIDE
NEGATIVE PRESSURE MONITORS, MINIMUM (1) ONE IN AREAS LESS THAN 1000 SF,
(2) TWO MINIMUM IN AREAS BETWEEN 1000 SF AND 5000 SF, AND (3) THREE FOR
AREAS BETWEEN 5000 SF AND 10000 SF.
8. LIFE SAFETY EGRESS IS TO BE MAINTAINED AT ALL TIMES.
9. THE CONTRACTOR SHALL PROVIDE ENOUGH NEGATIVE AIR MACHINES TO
COMPLETELY EXCHANGE THE REGULATED AREA AIR VOLUME (4) FOUR ACTUAL
TIMES PER HOUR. THE COMPETENT PERSON SHALL DETERMINE THE NUMBER OF
UNITS NEEDED FOR EACH REGULATED AREA BY DIVIDING THE CUBIC FEET IN THE
REGULATED AREA BY (15) FIFTEEN AND THEN DIVIDING THAT RESULT BY THE
ACTUAL CUBIC FEET PER MINUTE (CFM) FOR EACH UNIT TO DETERMINE THE
NUMBER OF UNITS NEEDED TO EFFECT (4) FOUR AIR CHANGES PER HOUR.
PROVIDE A STANDBY UNIT IN THE EVENT OF MACHINE FAILURE AND/OR
EMERGENCY IN AN ADJACENT AREA.
10. PRIOR TO ANY REMOVAL OF SMOKE BARRIER FIRE RATED PARTITIONS,
CONSTRUCT NEW SMOKE BARRIER/APPROPRIATE FIRE RATED PARTITIONS PER
PLANS OR CONSTRUCT INFECTION CONTROL BARRIER TO ACT AS SMOKE
BARRIER.
CONSTRUCTION PHASING
GENERAL NOTES
1. THE WORK UNDER THIS CONTRACT SHALL BE DIVIDED INTO PHASES. A PHASE
CAN INVOLVE MULTIPLE LOCATION AREAS. SEE SPECIFICATIONS SECTION 01 00 00
1.6.G PHASING.
2. THE GENERAL CONTRACTOR SHALL COORDINATE ALL PHASING AND SEQUENCING
WITH ALL TRADES AND THE OWNER. THE GENERAL CONTRACTOR SHALL PROVIDE
A DETAILED WRITTEN NARRATIVE TO OUTLINE CONSTRUCTION PHASING AND
SEQUENCE PLANS, VALIDATING AND ELABORATING ON THIS PHASING
DESCRIPTION.
3. THE GENERAL CONTRACTOR SHALL COOPERATE FULLY WITH THE OWNER SO
WORK MAY BE CARRIED OUT SMOOTHLY, WITHOUT INTERFERING WITH OR
DELAYING WORK UNDER THIS CONTRACT, OR OTHER CONTRACTS ON THE
PROJECT SITE OR WORK BY OWNER.
4. THE GENERAL CONTRACTOR'S CONSTRUCTION SCHEDULE SHALL INDICATE THE
SEQUENCE, COMMENCEMENT AND COMPLETION DATES, OWNER INSPECTION AND
APPROVAL DATES AND MOVE-OUT AND MOVE-IN DATES OF OWNER'S PERSONNEL
FOR ALL PHASES OF THE WORK.
5. THE GENERAL CONTRACTOR SHALL PERFORM THE WORK IN EACH PHASE IN THE
SEQUENCE SHOWN ON THE PHASING PLAN DRAWING(S) AND CONSTRUCTION
PHASING DESCRIPTION.
6. THE GENERAL CONTRACTOR MUST COMPLETE ALL WORK IN EACH PHASE WITH
THE VA INSPECTING AND ACCEPTING THE WORK PRIOR TO VA OCCUPANCY AND
THE CONTRACTOR PROCEEDING TO THE NEXT SCHEDULED PHASE. UPON
COMPLETION OF A PARTICULAR PHASE, THE ENTIRE AREA COVERED BY THAT
PHASE CAN BE OCCUPIED BY THE VA PERSONNEL WITH ALL SYSTEMS
FUNCTIONING PROPERLY.
7. BEFORE COMMENCING WORK ON EACH SUCCESSIVE PHASE, THE GENERAL
CONTRACTOR SHALL SUBMIT AN UPDATED COPY OF THE SCHEDULE.
8. ANY DUST PARTITIONS OR ICRA - CONSTRUCTION BARRIERS CONSTRUCTED BY
THE CONTRACTOR PRIOR TO THE START OF DEMOLITION MUST REMAIN IN PLACE
UNTIL THE COMPLETION OF THAT PHASE OR SUBSEQUENT PHASE WHERE
REQUIRED.
9. THE CONTRACTOR SHALL PERFORM ALL WORK ADJACENT TO VA OCCUPIED
AREAS IN SUCH A MANNER TO ENSURE THE CONTINUOUS AND UNINTERRUPTED
USE OF ALL OCCUPIED AREAS, INCLUDING THE APPLICABLE MECHANICAL AND
ELECTRICAL SYSTEMS SERVING THESE AREAS.
10. FOR ADDITIONAL NOTES AND INFORMATION REFER TO INFECTION CONTROL
DRAWING(S) AND DEMOLITION PLANS.
11. ANY INFORMATION REGARDING SEQUENCING PROVIDED IN THE DOCUMENTS IS
FOR ARCHITECT-OWNER PLANNING PURPOSES ONLY.
12. THE CONTRACTOR DURING CONSTRUCTION SHALL MAINTAIN REQUIRED MEANS
OF EGRESS THROUGHOUT ALL PHASING.
13. THE CONTRACTOR SHALL PLAN FOR A MINIMUM OF 4 WEEKS' TIME BETWEEN
PHASES TO ALLOW THE VA TO OCCUPY THE NEWLY ACCEPTED SPACE AND
VACATE THE FOLLOW-ON PHASES. THE VA WILL ACCELERATE THIS TIME WHEN
POSSIBLE AND WILL NOTIFY THE CONTRACTOR IF THIS OCCURS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES Project :
B
IM
/2
V
A T o m a h
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-7
.B
.A
R
.r v t
/7
/2
:3
:5
A
M
B25-GC111
FIRST LEVEL INFECTION
CONTROL & PHASING PLAN
EHRM Infrastructure Upgrades
Tomah, WI
676-21-700
B25
2/11/22 GJB GJB
16477
3/16" = 1'-0"
FIRST LEVEL ICRA, CONSTRUCTION BARRIER & PHASING PLAN
NOTE:
• PROVIDE 1 HOUR FIRE RATED, STARC SYSTEMS FIREBLOCK WALL
PANELS OR APPROVED EQUAL FOR ALL ICRA/CONSTRUCTION
BARRIERS AND MODIFY SPRINKLER HEADS TO BE UPTURNED AND
EXTENDED TO 18" OF STRUCTURE.
• MOBILE ICRA CONTAINMENT SYSTEMS WILL NEED TO BE USED IN
AREAS OF WORK THAT ARE OUTSIDE OF THE INDICATED ICRA /
CONSTRUCION BARRIER LOCAIONS. SEE MEPT DRAWINGS FOR
ADDITIONAL AREAS OF WORK.
ICRA / CONSTRUCTION BARRIER
OFFICE
OFFICE OFFICE
CONFERENCE
RECEPTION
AREA
OFFICE
S T
O R
A G
E
T O
IL
E
T
CORRIDOR
U T
IL
IT
Y
T O
IL
E
T
T O
IL
E
T
ROOM
4 10
WAREHOUSE/STORAGE
D
D
D
D
W
W
W
SECOND FLOOR LEVEL
DN
118A
TELECOM
WAREHOUSE
B25-AE111
B25-AE111
118A
TELECOM
WAREHOUSE
8' -0
10'-0"
LIMITS OF CONSTRUCTION
LI
M
IT
S
O F
C O
N S
T R
U C
T
IO
N
118A
CR
B3bs
FL8
B6bs
FL6
PANEL PREFIXES
AL- ALUMINUM
CG- COILING GRILLE
CS- COILING SLATS
HM- HOLLOW METAL
OS- OVERHEAD SECTIONAL
RD3- REVOLVING DOOR 3 PANEL
RD4- REVOLVING DOOR 4 PANEL
VL- VERTICAL LIFT
WD- WOOD
AG ALL GLASS
BF BIFOLD
BFGBIFOLD GLASS
D DUTCH
DG DUTCH GLASS
DSDUTCH W/SHELF
FFLUSH
G2GLASS 2 LIGHT
G3GLASS 3 LIGHT
GFGLASS FULL
GH GLASS HALF
LF LOUVER FULL
LGHLOUVER GLASS HALF
LH LOUVER HALF
HM-GF
FRAME PREFIXES
0 FRAMED-CASED OPENING
1 DOOR ONLY
2 SIDELIGHT(S) 1 SIDE
3 SIDELIGHT(S) 1 SIDE W/HORIZONTAL
4 SIDELIGHT(S) BOTH SIDES
5 SIDELIGHT(S) BOTH SIDES W/HORIZONTAL
6 DOOR W/TRANSOM
7 DOOR W/TRANSOM W/SIDELIGHT(S) 1 SIDE
8 TRANSOM W/SIDELIGHT(S) 1 SIDE W/HORIZONTAL
9 TRANSOM W/SIDELIGHT(S) BOTH SIDES
10 TRANSOM W/SIDELIGHT(S) BOTH SIDES W/HORIZONTAL
11 FULL WIDTH TRANSOM W/SIDELIGHT(S) 1 SIDE
1X1 1 LIGHT WIDE AND 1 LIGHT HIGH
2X2 2 LIGHTS WIDE AND 2 LIGHTS HIGH
3X3 3 LIGHTS WIDE AND 3 LIGHTS HIGH
(NOTE: OTHER COMBINATIONS POSSIBLE)
OX FIXED PANEL, ACTIVE PANEL
OXO FIXED PANEL, ACTIVE PANEL, FIXED PANEL
OXX FIXED, ACTIVE, ACTIVE
OXXO FIXED, ACTIVE, ACTIVE, FIXED
OXXXXO FIXED, ACTIVE, ACTIVE, ACTIVE, ACTIVE, FIXED
HMS-2
LNV LOUVER NARROW VISION
NVNARROW VISION
NV2 NARROW VISION 2 LIGHT
NV3 NARROW VISION 3 LIGHT
NVCNARROW VISION CENTERED
RP2 RAISED PANEL 2 PANEL
RP4 RAISED PANEL 4 PANEL
RP6 RAISED PANEL 6 PANEL
RP8 RAISED PANEL 8 PANEL
VVISION
W WINDOWS (1 ROW)
WT WINDOWS THROUGHOUT
DOOR PANEL NAMING
DOOR FRAME NAMING NOTE: ACTUAL FRAMES MAY VARY FROM DESCRIPTIONS
BELOW, REFER TO FRAME TYPE ELEVATIONS
NOTE: ACTUAL PANELS MAY VARY FROM DESCRIPTIONS
BELOW, REFER TO PANEL TYPE ELEVATIONS
PANEL SUFFIXES
AL- ALUMINUM
AL-BL- ALUMINUM BORROWED LIGHT
AL-SL- ALUMINUM SLIDING
ALR- ALUMINUM REVOLVING
CW## CURTAINWALL
HMM- HOLLOW METAL MASONRY
HMM-BL- HMM BORROWED LIGHT
HMM-DE- HMM DOUBLE EGRESS
HMS- HOLLOW METAL STUD
HMS-BL- HMS BORROWED LIGHT
HMS-DE- HMS DOUBLE EGRESS
OC- OVERHEAD COILING
OS- OVERHEAD SECTIONAL
VL- VERTICAL LIFT
WD- WOOD
WD-BL- WOOD BORROWED LIGHT
WDP- WOOD POCKET
FRAME SUFFIXES
FINISHED
FLOOR
HM-F
WD-F
WIDTH
OPENING
O P
E N
IN
G
H E
IG
H
T
FINISHED
FLOOR
HMS-1
O P
E N
IN
G
H E
IG
H
T
WIDTH
OPENING
FLOOR PLAN KEYED NOTES
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
FL1
PATCH PARTITION, WITH MATERIALS TO MATCH EXISTING ADJACENT
SURFACES, AS REQUIRED FROM DEMOLITION. WHERE EXISTING FINISHES
ARE DISTURBED PAINT TO MATCH ADJACENT FINISH, PAINT ENTIRE
PARTITION WHERE PATCHING OCCURS.
FL2
PROVIDE PLYWOOD 3 SIDES OF ROOM. SEE TYPICAL ELEVATIONS SHEET
AE211
FL3
PROVIDE METAL STUDS, AS REQUIRED AND GYP BD BOTH SIDES OF
PARTITION, ABOVE REMOVED CEILING TO UNDERSIDE OF DECK ABOVE.
WHERE PATCHING IS VISIBLE IN ROOM, PAINT TO MATCH ADJACENT FINISH,
PAINT ENTIRE PARTITION WHERE PATCHING OCCURS.
FL4
PATCH PARTITION, WITH MATERIALS TO MATCH EXISTING ADJACENT
SURFACES, AS REQUIRED FROM REMOVAL OF MECHANICAL, ELECTRICAL,
PLUMBING AND/ OR FIRE PROTECTION ITEMS. WHERE EXISTING FINISHES
ARE DISTURBED PAINT TO MATCH ADJACENT FINISH, PAINT ENTIRE
PARTITION WHERE PATCHING OCCURS. SEE MEP DRAWINGS FOR
ADDITIONAL INFORMATION
FL5
INFILL OPENING. PATCH ADJACENT SURFACES WITH MATERIALS TO MATCH
EXISTING AS REQUIRED FROM DEMOLITION. WHERE EXISTING FINISHES
ARE DISTURBED PAINT TO MATCH ADJACENT FINISH, PAINT ENTIRE
PARTITION WHERE PATCHING OCCURS. BOTH SIDES.
FL6
PROVIDE BLAST RESISTANT FILM APPLIED TO THE INSIDE FACE (ROOM
SIDE) OF GLASS. INSTALL PER MANUFACTURES INSTRUCTIONS FOR BLAST
RESISTANCE.
FL7
PATCH / MODIFY ACT CEILING TILE AND GRID AS NECESSARY,
CONTRACTOR TO PROVIDE LABOR AND MATERIALS. REPLACE ANY
BROKEN, DAMAGED OR DIRTY ACT TILES AND CEILING GRID. COORDINATE
WITH OWNER FOR ACT AND CEILING GRID TYPE. WHERE EXISTING
FINISHES ARE DISTURBED ON PAINTED SURFACES. PAINT TO MATCH
ADJACENT FINISH. PAINT ENTIRE PARTITION / SOFFIT OF EXISTING
INTERIOR SPACES WHERE PATCHING OCCURS.
FL8
PROVIDE SEMI-RECESSED RATED FIRE EXTINGUISHER CABINET. SEE
DRAWINGS AND LIFE SAFETY SYMBOLS FOR ADDITIONAL INFORMATION
FL9
PATCH METAL LATH AND PLASTER CEILING AS REQUIRED FROM
DEMOLITION. PAINT TO MATCH EXISTING FINISHES. PAINT ENTIRE CEILING
WHERE PATCHING OCCURS.
FL10
UPGRADE PARTITIONS TO 1 HOUR FIRE AND SMOKE BARRIER WHERE
INDICATED ON PLAN. PROVIDE TESTED HEAD OF PARTITION ASSEMBLY
WITH MATERIALS THAT RESIST THE PASSAGE OF SMOKE. SEAL JOINT AT
HEAD AND ALL PENETRATIONS WITH FIRE CAULK.
FL11
REINSTALL CEILING TILE AND GRID AS REQUIRED FROM DEMOLITION,
MECHANICAL, ELECTRICAL, PLUMBING, TELECOM OR FIRE PROTECTION
WORK. REPLACE ANY BROKEN, DAMAGED OR DIRTY ACT TILES AND
CEILING GRID. COORDINATE WITH OWNER FOR ACT AND CEILING GRID
TYPE. SEE MEPT FOR ADDITIONAL INFORMATION.
FL12
PROVIDE UL RATED 1 HOUR HORIZONTAL SHAFT WALL ASSEMBLY AT
CEILING TIGHT TO UNDERSIDE OF EXISTING STRUCTURE ABOVE. WHERE
EXISTING FINISHES ARE DISTURBED ON PAINTED SURFACES. PAINT TO
MATCH ADJACENT FINISH. PAINT ENTIRE PARTITION ON INTERIOR SPACES
WHERE PATCHING OCCURS. PAINT CEILING TO MATCH ADJACENT FINISH.
118A
TELECOM
WAREHOUSE
IN-03.01
FN4
FN2
FINISH PLAN KEYED NOTES
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
FN1
FINISH PARTITION TO MATCH EXISTING THIS AREA, INCLUDING, BUT NOT
LIMITED TO, PAINT, WALLCOVERING, WALL PROTECTION AND WALL BASE.
CONTRACTOR TO PROVIDE LABOR AND MATERIALS
FN2 FINISH PARTITION WITH P-2 & RB-1.
FN3
MODIFY RAILING AS REQUIRED. PROVIDE RAILING SUPPORTS, ENDCAPS,
RETURNS AND ALL HARDWARE, TO MATCH EXISTING. AS REQUIRED FOR
INSTALLATION.
FN4
TELECOM ROOM TYPICAL FINISHES; SD-1 AT FLOOR, RB-1 AT BASE. ALL
WALL MOUNTED PLYWOOD TO HAVE FP-1, ALL OTHER WALL SURFACES TO
HAVE P-1. SEE 1 & 2/AE211 FOR ADDITONAL INFORMATION.
FN5
WHERE EXISTING FINISHES ARE DISTURBED BY CONSTRUCTION, FINISH TO
MATCH ADJACENT FINISHES, FINISH ENTIRE PORTION OF PARTITION AS
SHOWN WITHIN DIMENSION.
FN6
MODIFY RAILING AS REQUIRED. PROVIDE RAILING SUPPORTS, ENDCAPS,
RETURNS AND ALL HARDWARE, TO MATCH EXISTING AS REQUIRED FOR
INSTALLATION – HR-2.
FN7
MODIFY RAILING AS REQUIRED. PROVIDE RAILING SUPPORTS, ENDCAPS,
RETURNS AND ALL HARDWARE, TO MATCH EXISTING AS REQUIRED FOR
INSTALLATION – HR-3.
FN8 INSTALL NEW HANDRAIL HR-2.
FN9
MODIFY RAILING AS REQUIRED. PROVIDE RAILING SUPPORTS, ENDCAPS,
RETURNS AND ALL HARDWARE, TO MATCH EXISTING AS REQUIRED FOR
INSTALLATION OR INSTALL NEW; CONTRACTOR'S CHOICE – HR-4.
FN10 FINISH PARITION WITH P-1 & REINSTALL SALVAGED CARPET BASE.
FN11 INSTALL CG-1, COLOR 0154 CLAM SHELL
FN12 SEE DETAIL _/AF601 FOR WALL FINISHES
FN13 FINISH PARTITION WITH P-6 & RB-3
FN14 FINISH PARTITION WITH P-2 & RB-3
FN15 FINISH PARTITION WITH P-2 & RB-4
LIFE SAFETY SYMBOLS
SMOKE TIGHT
ASSEMBLY
1 HOUR FIRE
BARRIER
2 HOUR FIRE
BARRIER
3 HOUR FIRE
BARRIER
1 HOUR FIRE &
SMOKE BARRIER
2 HOUR FIRE &
SMOKE BARRIER
3 HOUR FIRE &
SMOKE BARRIER
LIMITS OF
CONSTRUCTION
NOTE: NOT ALL SYMBOLS MY BE USED ON EACH PLAN
118A
TELECOM
WAREHOUSE
CO2 FEC
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES Project :
B
IM
/2
V
A T o m a h
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-7
.B
.A
R
.r v t
/7
/2
:3
:0
A
M
B25-AE111
FIRST LEVEL & ENLARGED PLANS,
OPENING SCHEDULED
EHRM Infrastructure Upgrades
Tomah, WI
676-21-700
B25
2/11/22 GJB GJB
16477
1/8" = 1'-0"
FIRST LEVEL FLOOR PLAN
0 8' 16'4'
1/4" = 1'-0"2
ENLARGED PLAN - FIRST LEVEL - TELECOM 118A
OPENING SCHEDULE
ASSOCIATED ROOMS OPENING PANEL INFORMATION FRAME INFORMATION
H D
W G
R O
U P
F
IR
E L
A B
E L
(M
IN
G A
S K
E T
E
LE
C T
R
IC
A L
S L
A B
E L
COMMENTSFROM ROOM NAME TO ROOM NAME NUMBER WIDTH HEIGHT
PANEL
TYPE
2ND
PANEL
TYPE
PANEL
GLAZING FRAME TYPE
FRAME
GLAZING
WAREHOUSE TELECOM 118A 3'-0" 7'-0" WD-F NONE HMS-1 NONE HW-3.
45 Y Y Y
TYPES - PANELS TYPES - FRAMES
1/4" = 1'-0"3
ENLARGED FINISH PLAN - FIRST LEVEL - TELECOM 118A
NOTE:
- COORDINATE WORK WITH ABATEMENT AND REMEDIATION WORK
- SEE SHEET GI003 FOR GENERAL NOTES AND SYMBOLS
0 4' 8'2'0 4' 8'2'1/4" = 1'-0"4
ENLARGED LIFE SAFETY PLAN - PARTIAL FIRST LEVEL
0 4' 8'2'
1D
2D
D
D
7D 1D 1D 1D
2D
4D
4D
D
4D
105A
TELECOM
105B
STORAGE
CONSTRUCTION PROJECT ACTIVITY TYPE - D
INFECTION CONTROL RISK GROUP - GROUP 1: LOW RISK
CONTROL PROCEDURE CLASS - III
INFECTION CONTROL RISK ASSESSMENT (ICRA) BY
PROJECT AREA USE AND PHASE
CONSTRUCTION INFECTION CONTROL RISK ASSESSMENT (ICRA)
TYPE A
TYPE B
TYPE C
TYPE D
INSPECTIONS AND NON-INVASIVE ACTIVITIES. INCLUDES, BUT NOT
LIMITED TO, REMOVAL OF CEILING TILES FOR VISUAL INSPECTION
LIMITED TO 1 TILE PER 50 SQUARE FEET, PAINTING BUT NOT SANDING
WALL COVERING, ELECTRICAL TRIM WORK, MINOR PLUMBING, AND
ACTIVITIES WHICH DO NOT GENERATE DUST OR REQUIRE CUTTING OF
WALLS OR ACCESS TO CEILINGS OTHER THAN FOR VISUAL INSPECTION.
SMALL SCALE, SHORT DURATION ACTIVITIES WHICH CREATE MINIMAL
DUST. INCLUDES, BUT IS NOT LIMITED TO, INSTALLATION OF TELEPHONE
AND COMPUTER CABLING, ACCESS TO CHASE SPACES, CUTTING OF
WALLS OR CEILING WHERE DUST MIGRATION CAN BE CONTROLLED.
FLOOR COVERING REMOVAL (WITHOUT SANDING OR GRINDING).
ANY WORK THAT GENERATES A MODERATE TO HIGH LEVEL OF DUST OR
REQUIRES DEMOLITION OR REMOVAL OF ANY FIXED BUILDING
COMPONENTS OR ASSEMBLIES. INCLUDES, BUT IS NOT LIMITED TO,
SANDING OF WALL FOR PAINTING OR WALLCOVERING, REMOVAL OF
FLOOR COVERINGS, CEILING TILES AND CASEWORK, NEW WALL
CONSTRUCTION, MINOR DUCTWORK OR ELECTRICAL WORK ABOVE
CEILINGS, MAJOR CABLING ACTIVITIES, AND ANY ACTIVITY WHICH
CANNOT BE COMPLETED WITHIN A SINGLE WORK SHIFT. FLOOR
COVERING REMOVAL (WITH SANDING OR GRINDING).
MAJOR DEMOLITION AND CONSTRUCTION PROJECTS. INCLUDES, BUT IS
NOT LIMITED TO, ACTIVITIES WHICH REQUIRE CONSECUTIVE WORK
SHIFTS, REQUIRE HEAVY DEMOLITION OR REMOVAL OF A COMPLETE
CEILING SYSTEM, FLOORING AND NEW CONSTRUCTION.
GROUP 1
LOW RISK
• MECHANICAL SPACES: AREAS NOT DIRECTLY ADJACENT TO PATIENT
CARE, INCLUDING INTERSTITIAL SPACES.
• ENGINEERING OR EMS OFFICE/WORK AREAS
• OFFICE AREAS: AREAS NOT ATTACHED TO/ADJOINING PATIENT CARE
AREAS, NOT USED FOR PATIENT INTERVIEWS, EVALUATIONS OR
EXAMINATIONS.
• PUBLIC CORRIDORS: SPACES NOT ON OR DIRECTLY ATTACHED TO
PATIENT UNITS OR TREATMENT LOCATIONS.
GROUP 2
MEDIUM
RISK
• OUTPATIENT AREAS:
1. PRIMARY CARE OR SPECIALTY CARE CLINIC AREAS
2. BEHAVIORAL/MENTAL HEALTH AREAS
3. EXTENDED CARE / REHAB CLINIC AREAS
4. COMMUNITY BASED OUT PATIENT CLINICS (CBOC’S)
GROUP 3
HIGH RISK
• IN-PATIENT UNITS:
1. INCLUDING, BUT NOT LIMITED TO: EMERGENCY DEPT.; NURSING
UNITS; RADIOLOGY/MRI/CT/ULTRASOUND; NUCLEAR MEDICINE;
CAFETERIA/KITCHEN/CANTEEN; LABORATORIES; RADIATION /
ONCOLOGY; DIALYSIS
GROUP 4
HIGHEST
RISK
• ICU/SICU
• OR/PACU/ENDOSCOPY
• GI
• STERILE PROCESSING SERVICES (SPS)
• PHARMACY
• CATH LAB
CLASS
I
KEEP AREAS FREE OF DEBRIS, TRASH
EXECUTE WORK TO MINIMIZE OF DUST MIGRATION (E.G. WET MOPPING, HEPA VACUUM)
IMMEDIATELY REPLACE ANY CEILING TILE DISPLACED FOR VISUAL INSPECTION
(INVOLVING MINOR DEMOLITION IN MAINTENANCE OR REMODELING.)
CLASS
II
SAME AS CLASS I PLUS:
1. ESTABLISH MATERIAL AND DEBRIS ROUTE USING NON-PATIENT/VISITOR PATHWAY
2. WATER MIST WORK SURFACE TO CONTROL DUST WHILE CUTTING OR DRILLING.
3. BLOCK OFF AND SEAL AIR VENTS
4. SEAL UNUSED DOORS WITH PLASTIC SHEATHING AND DUCT TAPE.
5. CREATE BARRIERS AS DEFINED BY INFECTION PREVENTION
6. CONTAIN CONSTRUCTION WASTE BEFORE TRANSPORT IN TIGHTLY COVERED CONTAINER; TAPE COVERING UNLESS SOLID LID.
7. WET MOP AND/OR VACUUM WITH HEPA FILTERED VACUUM BEFORE LEAVING WORK AREA.
8. PLACE STICKY MAT AT ALL WORK AREA ENTRANCES AND EXITS.
9. REMOVE OR ISOLATE HVAC SYSTEM IN CONSTRUCTION AREA
CLASS
III
SAME AS CLASS I AND II PLUS:
1. ISOLATE HVAC SYSTEM IN CONSTRUCTION AREA TO PREVENT DUCT SYSTEM CONTAMINATION
2. COMPLETE CRITICAL BARRIERS (I.E. SHEETROCK, PLYWOOD, PLASTIC) AT ALL CONSTRUCTION ENTRIES AND EXITS; MONITOR FOR SEAL AND TAKE IMMEDIATE
CORRECTIVE ACTION AS NEEDED
3. MAINTAIN AND MONITOR NEGATIVE AIR PRESSURE WITHIN CONSTRUCTION SITE UTILIZING HEPA EQUIPPED AIR FILTRATION UNITS.
4. REMOVE OR ISOLATE HVAC SYSTEMS IN AREA WHERE WORK IS BEING PERFORMED.
5. CHECK AND REPLACE AIR FILTERS AS NEEDED REGULARLY
6. DO NOT REMOVE BARRIERS FROM WORK SITE UNTIL PROJECT IS COMPLETE & HAS BEEN THOROUGHLY CLEANED; REMOVE BARRIERS CAREFULLY TO MINIMIZE
SPREADING DUST. DEBRIS.
7. VACUUM WORK WITH HEPA FILTERED VACUUM.
8. WET MOP AREA WITH CLEANER/DISINFECTANT.
9. MITIGATE VIBRATION AND NOISE TO LOWEST IMPACT WHERE POSSIBLE.
10. DISPLAY ICRA AT SITE
11. SEAL HOLES, PIPES, CONDUITS AND PUNCTURES.
CLASS
IV
SAME AS CLASS I, II AND III PLUS:
1. INSPECT ADJACENT AREAS FOR DUST MIGRATION; TAKE IMMEDIATE CORRECTIVE AS NEEDED
2. USE HEPA VACUUM IN AREA PRIOR TO START OF CONSTRUCTION
3. CONSTRUCT ANTE ROOM; ALL PERSONNEL MUST ENTER THROUGH IT TO BE VACUUMED USING HEPA VACUUM BEFORE LEAVING OR TO DON/DOFF PPE
INFECTION CONTROL &
CONSTRUCTION BARRIER
GENERAL NOTES
1. SEE SPEC SECTION 01 35 26 SAFETY REQUIREMENTS FOR ADDITIONAL
INFORMATION
2. THE INTENT OF INFECTION CONTROL ISOLATION IS TO CONTAIN DUST AND
PARTICULATE MATTER TO THE CONSTRUCTION AREA. CONSTRUCTION AREA
PERIMETER NEEDS TO BE SEALED COMPLETELY WITH SHEET PLASTIC AS
SPECIFIED AND DUCT TAPE DURING OPERATIONS, WHERE PERMITTED BY CLASS.
ICRA - CONSTRUCTION BARRIER TO BE PROVIDED AS SPECIFIED AND LISTED IN
ICRA CLASS.
3. PROVIDE NEGATIVE PRESSURE MONITORS DURING CONSTRUCTION OPERATIONS
AS SPECIFIED. MONITOR TO MEASURE PRESSURE DIFFERENTIAL BETWEEN
CONSTRUCTION AREA AND ADJACENT CORRIDOR OR ROOM AS DIRECTED BY VA.
4. AS CONSTRUCTION PROGRESSES, FROM TYPE D TO TYPE C AND THEREON,
PROVIDE A REQUEST VIA "INFECTION CONTROL CONSTRUCTION PERMIT" TO THE
VA INFECTION CONTROL NURSE. UPON AUTHORIZATION, PROCEED TO NEXT TYPE
OF CONSTRUCTION. PROVIDE AT LEAST TEN (10) WORKING DAYS NOTICE FOR
EACH PERMIT.
5. CONSTRUCT IC (INFECTION CONTROL) CONSTRUCTION BARRIER(S) FROM FLOOR
TO DECK/FLOOR ABOVE.
6. CONTROL BARRIERS ARE TO BE INSTALLED AND REMOVED ONLY BEFORE 7:00 AM
AND AFTER 8:00 PM OR DIRECTED BY COR
7. DURING CONSTRUCTION OPERATIONS IN EACH ENCLOSED AREA PROVIDE
NEGATIVE PRESSURE MONITORS, MINIMUM (1) ONE IN AREAS LESS THAN 1000 SF,
(2) TWO MINIMUM IN AREAS BETWEEN 1000 SF AND 5000 SF, AND (3) THREE FOR
AREAS BETWEEN 5000 SF AND 10000 SF.
8. LIFE SAFETY EGRESS IS TO BE MAINTAINED AT ALL TIMES.
9. THE CONTRACTOR SHALL PROVIDE ENOUGH NEGATIVE AIR MACHINES TO
COMPLETELY EXCHANGE THE REGULATED AREA AIR VOLUME (4) FOUR ACTUAL
TIMES PER HOUR. THE COMPETENT PERSON SHALL DETERMINE THE NUMBER OF
UNITS NEEDED FOR EACH REGULATED AREA BY DIVIDING THE CUBIC FEET IN THE
REGULATED AREA BY (15) FIFTEEN AND THEN DIVIDING THAT RESULT BY THE
ACTUAL CUBIC FEET PER MINUTE (CFM) FOR EACH UNIT TO DETERMINE THE
NUMBER OF UNITS NEEDED TO EFFECT (4) FOUR AIR CHANGES PER HOUR.
PROVIDE A STANDBY UNIT IN THE EVENT OF MACHINE FAILURE AND/OR
EMERGENCY IN AN ADJACENT AREA.
10. PRIOR TO ANY REMOVAL OF SMOKE BARRIER FIRE RATED PARTITIONS,
CONSTRUCT NEW SMOKE BARRIER/APPROPRIATE FIRE RATED PARTITIONS PER
PLANS OR CONSTRUCT INFECTION CONTROL BARRIER TO ACT AS SMOKE
BARRIER.
CONSTRUCION PHASING
GENERAL NOTES
1. THE WORK UNDER THIS CONTRACT SHALL BE DIVIDED INTO PHASES. A PHASE
CAN INVOLVE MULTIPLE LOCATION AREAS. SEE SPECIFICATIONS SECTION 01 00 00
1.6.__ PHASING.
2. THE GENERAL CONTRACTOR SHALL COORDINATE ALL PHASING AND SEQUENCING
WITH ALL TRADES AND THE OWNER. THE GENERAL CONTRACTOR SHALL PROVIDE
A DETAILED WRITTEN NARRATIVE TO OUTLINE CONSTRUCTION PHASING AND
SEQUENCE PLANS, VALIDATING AND ELABORATING ON THIS PHASING
DESCRIPTION.
3. THE GENERAL CONTRACTOR SHALL COOPERATE FULLY WITH THE OWNER SO
WORK MAY BE CARRIED OUT SMOOTHLY, WITHOUT INTERFERING WITH OR
DELAYING WORK UNDER THIS CONTRACT, OR OTHER CONTRACTS ON THE
PROJECT SITE OR WORK BY OWNER.
4. THE GENERAL CONTRACTOR'S CONSTRUCTION SCHEDULE SHALL INDICATE THE
SEQUENCE, COMMENCEMENT AND COMPLETION DATES, OWNER INSPECTION AND
APPROVAL DATES AND MOVE-OUT AND MOVE-IN DATES OF OWNER'S PERSONNEL
FOR ALL PHASES OF THE WORK.
5. THE GENERAL CONTRACTOR SHALL PERFORM THE WORK IN EACH PHASE IN THE
SEQUENCE SHOWN ON THE PHASING PLAN…
This is the start of the file's text. The full file is on GovTribe.