Atch 18 - Electrical 3 of 4.pdf

PDF 19 MB Posted

Attached to
Y1AZ--EHRM Infrastructure Upgrades Construction - Tomah Federal contract opportunity
Solicitation number
36C77622B0031
Issued by
Department of Veterans Affairs Technology Acquisition Center Austin

About this file

This document provides details for a federal solicitation to conduct infrastructure upgrades at the Tomah VA Medical Center in Wisconsin. The solicitation seeks offers to perform upgrades to electrical, bonding, UPS, building management systems, HVAC, communication, physical security, and fiber infrastructure campus-wide within and between buildings. The upgrades also include modifications to impacted roads, walks, grading and drainage, and other existing utilities. Data center WAN updates and hazardous material abatement are required. The solicitation was issued by the Department of Veterans Affairs Technology Acquisition Center located in Austin, Texas, with solicitation number 36C77622B0031.

View the file

Other files for this federal contract opportunity

Other files attached to Y1AZ--EHRM Infrastructure Upgrades Construction - Tomah, newest first.
File Type Posted
36C77622B0031 0005.pdf PDF
Follow-up Questions and Responses 7-26-22.pdf PDF
36C77622B0031 0004.pdf PDF
36C77622B0031 0003.pdf PDF
Atch 28 - Construction Wage Rates - Monroe - 7-15-22.pdf PDF
Technical Questions - LATE - Tomah 7-20-22.pdf PDF
OIT-StdTelecomSpacesPgs64-67.pdf PDF
36C77622B0031 0002.pdf PDF
Atch 28 - Construction Wage Rates - Monroe - 6-17-22.pdf PDF
Technical Questions - FINAL - Tomah 7-6-22.pdf PDF
Site Visit Sign-in Sheet - Tomah 6-14-22.pdf PDF
36C77622B0031 0001.pdf PDF
Atch 1 - Specs Division 00-10.pdf PDF
Atch 8 - Civil 2 of 2.pdf PDF
Atch 10 - Architectural 2 of 2.pdf PDF
Atch 12 - Telecommunications 1 of 4.pdf PDF
Atch 14 - Telecommunications 3 of 4.pdf PDF
Atch 17 - Electrical 2 of 4.pdf PDF
Atch 20 - Mechanical 1 of 4.pdf PDF
Atch 22 - Mechanical 3 of 4.pdf PDF
Atch 23 - Mechanical 4 of 4.pdf PDF
Atch 25 - Appendix C-D Specs on TOC.pdf PDF
Atch 27 - Limitations on Subcontracting - Construction.docx DOCX document
Atch 28 - Construction Wage Rates - Monroe - 4-29-22.pdf PDF
Atch 29 - Contractor Safety - Environmental Form.docx DOCX document
36C77622B0031 - 5-25-22.pdf PDF
Atch 2 - Specs Division 21-23.pdf PDF
Atch 15 - Telecommunications 4 of 4.pdf PDF
Atch 19 - Electrical 4 of 4.pdf PDF
Atch 24 - Appendix A-B Specs on TOC.pdf PDF
Atch 6 - General.pdf PDF
Atch 13 - Telecommunications 2 of 4.pdf PDF
Atch 16 - Electrical 1 of 4.pdf PDF
Atch 21 - Mechanical 2 of 4.pdf PDF
Atch 3 - Specs Division 26-28.pdf PDF
Atch 4 - Specs Division 31-33.pdf PDF
Atch 5 - Sheet Index - EHRM Upgrades.pdf PDF
Atch 7 - Civil 1 of 2.pdf PDF
Atch 9 - Architectural 1 of 2.pdf PDF
Atch 26 - COVID-19 Safety Protocols 12-14-21.pdf PDF
Atch 30 - Site Visit - Map.pdf PDF
Atch 11 - Hazmat.pdf PDF
Show all 42

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ELEV.

10500

10508

1050110599

10510

10512

10505

10511

10513

10515

10517

10518

10519

10520

10522

10521

10524

10526

10523

10525

10527

10528

01B 10B

11B

15B

18B

20B

19B

24B

23B

28B

10597

10596

10589

10591

10592

10588

10590

10585

10586

10577

10581

10583

UP

UP

EEE

B405-EP200

CU B405-2.1

CU B405-3.1

CU B405-1.1

B405-CR-1-5,7

B405-CR-1-9,11

B405-CR-1-1,3

B405-EP200

B405-EP200

DS-30R

DS-30R

DS-30R

B405IT-1-13

WP

/WP

/WP

/WP

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :

B

IM

/2

V

A T o m a h

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-7

.B

.E

T

R

.r v t

/8

/2

:3

:0

P M

B405-EP111

FIRST FLOOR - ELECTRICAL EHRM INFRASTRUCTURE

UPGRADES, TOMAH, WI

TOMAH, WI

676-21-700

B405

02/11/2022 GJL ASQ

16477

225 W WASHINGTON STREET

SUITE 2700 CHICAGO, IL 60606

312.294.0501 FAX: 312.294.0003

www.imegcorp.com # 21003227.00

SHEET NOTES:

1. CIRCUIT TO PANEL B405-MP-1-1 UNLESS

NOTED OTHERWISE.

N O R

HT

1/8" = 1'-0"

FIRST FLOOR - ELECTRICAL

0 8' 16'4'

Revisions: Date:

KEYNOTES:

1. OUTDOOR UNIT TO POWER INDOOR UNIT.

PROVIDE 2#10 & 1#12 IN 1/2" CONDUIT.

COORDINATE EXACT LOCATION WITH M.C.

20506

ELEV.

Lounge

20510

20508

20501

20500

20504

20584

84B

20583

20586

20585

83B

86B

20588

20587

20581

81B

20579

10B 20512

20511

11B

20513

20515

15B

20517

20519

20521

19B

20518

20516

20520

18B

20522

20524

22B 20523

20525

23B

20527

20599

20598

20595

20596

20593

20591

20589

87B

20577

20535

20537

37B20539

20541

20543 20545

77B 43B

45B

41B

39B

20544 20546

20503

20505

20547

93B

B405-EP200

B405-EP200

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :

B

IM

/2

V

A T o m a h

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-7

.B

.E

T

R

.r v t

/8

/2

:3

:0

P M

B405-EP112

SECOND FLOOR - ELECTRICAL EHRM INFRASTRUCTURE

UPGRADES, TOMAH, WI

TOMAH, WI

676-21-700

B405

02/11/2022 GJL ASQ

16477

225 W WASHINGTON STREET

SUITE 2700 CHICAGO, IL 60606

312.294.0501 FAX: 312.294.0003

www.imegcorp.com # 21003227.00

N O R

HT

1/8" = 1'-0"

SECOND FLOOR - ELECTRICAL

0 8' 16'4'

Revisions: Date:

CORR.

3C01

CORR.

3C06

CORR.

3C03

CORR.

3C03

ELEV.

EL01

CORR.

3C05

CORR.

3C07

CORR.

3C04

CORR.

3C08

CORR.

3C09

CORR.

3C10

STAIR 22

3S22

STAIR 23

3S23

30599 30501 30503

30505

30512

30511

30513

30504 30506

30516

30508

30515

30517

30519

30521

30523

30525

30527

30518

30520

30522

30524

3053730539

30541

3054330545

30547 30535

30577

30579

30581

30546

30584

30583

30586

30585

30587

30588

30589

30591

30593

30596

30595

30598 30500

12B

11B

15B

18B

19B

22B

23B

37B

39B

41B

43B

45B

81B

84B

83B

86B

87B

93B

DN

DN

B405-EP200

B405-EP200

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :

B

IM

/2

V

A T o m a h

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-7

.B

.E

T

R

.r v t

/8

/2

:3

:0

P M

B405-EP113

THIRD FLOOR - ELECTRICAL EHRM INFRASTRUCTURE

UPGRADES, TOMAH, WI

TOMAH, WI

676-21-700

B405

02/11/2022 GJL ASQ

16477

225 W WASHINGTON STREET

SUITE 2700 CHICAGO, IL 60606

312.294.0501 FAX: 312.294.0003

www.imegcorp.com # 21003227.00

N O R

HT

1/8" = 1'-0"

THIRD FLOOR - ELECTRICAL

10581

10592

E

1D-CAM

20598

D

D

D

E

30598

E

10592

SD 20598

SD

30598

SD

10592 20598 30598

B405-MSB-208

B405-NP-1-1 B405-MP-1-1

INVERTER

B405-ATS-208-CR

B405-CR-1

PANEL B405IT-1

SSAC B405-1.1

B405IT-1-CR-1

42"

B405IT-1-1

42"

B405IT-1-CR-1

42"

B405IT-1-1

42"

B405IT-1-CR-1

42"

B405IT-1-5,7,9

B405IT-1-CR-2,4,6

4 5

6 7

PANEL B405IT-1-CR

SSAC B405-2.1

NP-2-3-38,40,42

B405IT-2-CR-5,7,9

B405IT-2-CR-1

42"

B405IT-2-CR-1

42"

B405IT-2-CR-3

42"

B405IT-2-CR-1

42"

B405IT-2-CR

EXISTING PANEL NP-2-3

B405IT-3-CR-1

42"

B405IT-3-CR-1

42"

B405IT-3-CR-1

42"

B405IT-3-CR-2,4,6

B405IT-3-1,3,5

SSAC B405-3.1

PANEL B405IT-3

4 5

6 7

PANEL B405IT-3-CR

A

B405IT-1-CR

b

A

B405IT-1

a b a

A

B405IT-2-CR

b

A

B405IT-2-CR

a ab

A

B405IT-3-CR

b

A

B405IT-3

a ab

EXISTING PANEL NP-2-3

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :

B

IM

/2

V

A T o m a h

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-7

.B

.E

T

R

.r v t

/2

/2

:3

:0

P

M

B405-EP200

ELECTRICAL ENLARGED PLANS EHRM INFRASTRUCTURE

UPGRADES, TOMAH, WI

TOMAH, WI

676-21-700

B405

02/11/2022 GJL ASQ

16477

225 W WASHINGTON STREET

SUITE 2700 CHICAGO, IL 60606

312.294.0501 FAX: 312.294.0003

www.imegcorp.com # 21003227.00

N O R

HT

1/4" = 1'-0"

FIRST FLOOR - ELECTRICAL

POWER - EXISTING ELECTRICAL

ROOM

N O R

HT

1/4" = 1'-0"

FIRST FLOOR - ELECTRICAL

POWER - TR-405-1-1

N O R

HT

1/4" = 1'-0"

SECOND FLOOR - ELECTRICAL

POWER - TR-405-2-1

N O R

HT

1/4" = 1'-0"

THIRD FLOOR - ELECTRICAL

POWER - TR405-3-1

N O R

HT

1/4" = 1'-0"

FIRST FLOOR - ELECTRICAL

LIGHTING & FIRE ALARM -

TR405-1-1

KEYNOTES:

1. INDOOR UNIT TO BE POWERED BY OUTDOOR

UNIT. PROVIDE SWITCH & 120V CONNECTION

FOR CONDENSATE PUMP ASSOCIATED WITH

FAN UNIT FROM FAN UNIT POWER.

COORDINATE EXACT LOCATION WITH M.C.

2. CONNECT SMOKE DETECTOR TO NEAREST

EXISTING SLC.

3. NOT USED.

4. COORDINATE FINAL LOCATION OF

RECEPTACLE L21-30R WITH TELECOM

CONTRACTOR. PROVIDE 3/4"C-4#10, 1#12 GND

TO PANEL FOR EACH RECEPTACLE.

5. PROVIDE EATON BLADEUPS, 5KW, 120/208V, 3-

PHASE, 4-WIRE RACK MOUNTED UPS FOR

EACH RACK TOWER.

6. PROVIDE APC#AP8861 RPDU RACK PDU 2G

WITH L21-20P CORD. (120/208V, 3-PHASE, 20A,

ZERO U, 5.7 KW, 208V, (36) C13 (6) C19 (2) 5-20R

OUTLETS. PROVIDE TWO PER RACK, MOUNTED

PER MANUFACTURER'S REQUIREMENTS.

7. PROVIDE ONE RACK MOUNTED ZONE PDU

UNIT. 30 AMP 3 PHASE, 120/208V, 5-WIRE WITH

(4) L21-30R, (6) 5-20R AND TWO 10' POWER

CORDS. ZONIT#ZPDS-208V-30A-L21-4L21-20R-

CR.

N O R

HT

1/4" = 1'-0"

SECOND FLOOR - ELECTRICAL

LIGHTINF & FIRE ALARM -

TR-405-2-1

N O R

HT

1/4" = 1'-0"

THIRD FLOOR - ELECTRICAL

LIGHTING & FIRE ALARM -

TR405-3-1

CONSTRUCTION NOTES:

1. REFER TO TECHNOLOGY PLANS FOR IT ROOM

LAYOUT AND RACK LAYOUT/DETAILS.

2. REFER TO SHEET E003 DETAIL FOR LAYOUT &

ONE-LINE OF RACK.

0 4' 8'2' 0 4' 8'2' 0 4' 8'2'

0 4' 8'2' 0 4' 8'2' 0 4' 8'2' 0 4' 8'2'

0 4' 8'2' 0 4' 8'2' 0 4' 8'2'

Revisions: Date:

N O R

HT

1/4" = 1'-0"

FIRST FLOOR - ELECTRICAL

DEMOLITION - TR-405-11

N O R

HT

1/4" = 1'-0"

SECOND FLOOR - ELECTRICAL

DEMOLITION - TR-405-21

N O R

HT

1/4" = 1'-0"

THIRD FLOOR - ELECTRICAL

DEMOLITION - TR405-31

FIRST FLOOR

B405IT-1

4#3 & 1#8 GND.

IN 1 1/4" C.

B405-MSB-208

SECOND FLOOR

THIRD FLOOR

B405IT-3

4#3 & 1#8 GND.

IN 1 1/4" C. NP-2-3

B405IT-1-CR

4#3 & 1#8 GND.

IN 1 1/4" C.

B405-CR-1

B405IT-3-CR

4#3 & 1#8 GND.

IN 1 1/4" C.

B405IT-2-CR

4#3 & 1#8 GND.

IN 1 1/4" C.

4#3 & 1#8 GND.

IN 1 1/4" C.

G-424-

TERM

400/225A

3"C-4#300KCM &

1#3 GND

400/400A

400/400A

400/400A

150/110A

B404-ECB-LIFTSTA

B404-ECB-208CR

B404-ECB-208EQ

B404-ECB-208LS

B405-ATS-208-CR

250A, 208V, 3 PHASE,

4 WIRE

B405B424

4#3/0 & 1#6 GND

IN 2"C

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :

B

IM

/2

V

A T o m a h

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-7

.B

.E

T

R

.r v t

/8

/2

:3

:1

P M

B405-EP300

ELECTRICAL ONELINE DIAGRAM EHRM INFRASTRUCTURE

UPGRADES, TOMAH, WI

TOMAH, WI

676-21-700

B405

02/11/2022 GJL ASQ

16477

225 W WASHINGTON STREET

SUITE 2700 CHICAGO, IL 60606

312.294.0501 FAX: 312.294.0003

www.imegcorp.com # 21003227.00

NO SCALE

PARTIAL POWER RISER

Revisions: Date:

KEYNOTES:

1. PROVIDE NEW 100A/3P BREAKERS TO MATCH

EXISTING TYPE AND AIC RATING.

2. PROVIDE NEW 225A/3P CIRCUIT BREAKER TO

MATCH EXISTING TYPE AND AIC RATING.

3. CONTRACTOR SHALL ROUTE FEEDER

UNDERGROUND TO EXISTING TUNNEL SYSTEM

SERVING B404 FROM B403. ROUTE THROUGH

BASEMENT OF B404 AND THROUGH TUNNEL TO

B405.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :

B

IM

/2

V

A T o m a h

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-7

.B

.E

T

R

.r v t

/8

/2

:3

:1

P M

B405-EP400

ELECTRICAL SCHEDULES EHRM INFRASTRUCTURE

UPGRADES, TOMAH, WI

TOMAH, WI

676-21-700

B405

02/11/2022 GJL ASQ

16477

225 W WASHINGTON STREET

SUITE 2700 CHICAGO, IL 60606

312.294.0501 FAX: 312.294.0003

www.imegcorp.com # 21003227.00

CIRCUIT KEY NOTES:

*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.

TOTAL ESTIMATED DEMAND AMPS: 18.9 A

TOTAL CONNECTED AMPS: 26.97 A

Receptacles 0.54 kVA 70.00% 0.378 kVA TOTAL ESTIMATED DEMAND LOAD: 6.802 kVA

Power 9 kVA 70.00% 6.3 kVA TOTAL CONNECTED LOAD: 9.72 kVA

Lighting 0.178 kVA 70.00% 0.124 kVA

LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND

TOTALS*

LOAD SUMMARY

Total Amps: 29.73 25.00 26.71

Total Load: 3.54 kVA 3.00 kVA 3.18 kVA

-- 29 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 30 --

-- 27 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 28 --

-- 25 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 26 --

-- 23 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 24 --

-- 21 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 22 --

-- 19 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 20 --

-- 17 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 18 --

-- 15 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 16 --

13 CU GFI REC. 20 A 1 0.18 0 -- -- -- 1 20 A SPARE 14 --

11 LIGHTING 20 A 1 0.18 0 -- -- -- 1 20 A SPARE 12 --

-- 9 -- -- -- -- -- -- 3 0 -- -- -- 1 20 A SPARE 10 --

-- 7 -- -- -- -- -- -- 3 0 -- -- -- 1 20 A SPARE 8 --

5 L21-30R RACK 30 A 3 3 0 -- -- -- 1 20 A SPARE 6 --

-- 3 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 4 --

1 TELECOM ROOM REC. 20 A 1 0.36 0 -- -- -- 1 20 A SPARE 2 --

K E Y

CKT

NO. LOAD DESCRIPTION

OCPD

AMPS P

WIRE

SIZE

H N G

A B C

WIRE

SIZE

G N H

OCPD

P AMPS LOAD DESCRIPTION

CKT

NO.

K E Y

NOTES:

SCCR: 10 kA

LOCATION: WIRE: 4

FED FROM: 0 A/0P @ GROUND BUS PHASE: 3

ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye

MOUNTING: SURFACE MAIN: 100 A MCB

PANEL B405IT-1

CIRCUIT KEY NOTES:

*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.

TOTAL ESTIMATED DEMAND AMPS: 19.6 A

TOTAL CONNECTED AMPS: 27.97 A

Receptacles 0.72 kVA 70.00% 0.504 kVA TOTAL ESTIMATED DEMAND LOAD: 7.053 kVA

Power 9 kVA 70.00% 6.3 kVA TOTAL CONNECTED LOAD: 10.08 kVA

Lighting 0.356 kVA 70.00% 0.249 kVA

LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND

TOTALS*

LOAD SUMMARY

Total Amps: 29.73 26.50 28.19

Total Load: 3.54 kVA 3.18 kVA 3.36 kVA

-- 29 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 30 --

-- 27 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 28 --

-- 25 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 26 --

-- 23 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 24 --

-- 21 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 22 --

-- 19 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 20 --

-- 17 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 18 --

-- 15 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 16 --

-- 13 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 14 --

11 LIGHTING 20 A 1 0.36 0 -- -- -- 1 20 A SPARE 12 --

-- 9 -- -- -- -- -- -- 3 0 -- -- -- 1 20 A SPARE 10 --

-- 7 -- -- -- -- -- -- 3 0 -- -- -- 1 20 A SPARE 8 --

5 L21-30R RACK 30 A 3 3 0 -- -- -- 1 20 A SPARE 6 --

3 TELECOM ROOM REC. 20 A 1 0.18 0 -- -- -- 1 20 A SPARE 4 --

1 TELECOM ROOM REC. 20 A 1 0.54 0 -- -- -- 1 20 A SPARE 2 --

K E Y

CKT

NO. LOAD DESCRIPTION

OCPD

AMPS P

WIRE

SIZE

H N G

A B C

WIRE

SIZE

G N H

OCPD

P AMPS LOAD DESCRIPTION

CKT

NO.

K E Y

NOTES:

SCCR: 10 kA

LOCATION: WIRE: 4

FED FROM: 0 A/0P @ GROUND BUS PHASE: 3

ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye

MOUNTING: SURFACE MAIN: 100 A MCB

PANEL B405IT-2-CR

CIRCUIT KEY NOTES:

*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.

TOTAL ESTIMATED DEMAND AMPS: 17.8 A

TOTAL CONNECTED AMPS: 25.47 A

TOTAL ESTIMATED DEMAND LOAD: 6.424 kVA

Power 9 kVA 70.00% 6.3 kVA TOTAL CONNECTED LOAD: 9.18 kVA

Lighting 0.178 kVA 70.00% 0.124 kVA

LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND

TOTALS*

LOAD SUMMARY

Total Amps: 26.48 25.00 25.00

Total Load: 3.18 kVA 3.00 kVA 3.00 kVA

-- 29 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 30 --

-- 27 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 28 --

-- 25 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 26 --

-- 23 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 24 --

-- 21 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 22 --

-- 19 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 20 --

-- 17 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 18 --

-- 15 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 16 --

-- 13 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 14 --

-- 11 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 12 --

-- 9 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 10 --

7 LIGHTING 20 A 1 0.18 0 -- -- -- 1 20 A SPARE 8 --

-- 5 -- -- -- -- -- -- 3 0 -- -- -- 1 20 A SPARE 6 --

-- 3 -- -- -- -- -- -- 3 0 -- -- -- 1 20 A SPARE 4 --

1 L21-30R RACK 30 A 3 3 0 -- -- -- 1 20 A SPARE 2 --

K E Y

CKT

NO. LOAD DESCRIPTION

OCPD

AMPS P

WIRE

SIZE

H N G

A B C

WIRE

SIZE

G N H

OCPD

P AMPS LOAD DESCRIPTION

CKT

NO.

K E Y

NOTES:

SCCR: 10 kA

LOCATION: WIRE: 4

FED FROM: 0 A/0P @ GROUND BUS PHASE: 3

ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye

MOUNTING: SURFACE MAIN: 100 A MCB

PANEL B405IT-3

CIRCUIT KEY NOTES:

*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.

TOTAL ESTIMATED DEMAND AMPS: 18.9 A

TOTAL CONNECTED AMPS: 26.97 A

Receptacles 0.54 kVA 70.00% 0.378 kVA TOTAL ESTIMATED DEMAND LOAD: 6.802 kVA

Power 9 kVA 70.00% 6.3 kVA TOTAL CONNECTED LOAD: 9.72 kVA

Lighting 0.178 kVA 70.00% 0.124 kVA

LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND

TOTALS*

LOAD SUMMARY

Total Amps: 29.73 26.71 25.00

Total Load: 3.54 kVA 3.18 kVA 3.00 kVA

-- 29 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 30 --

-- 27 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 28 --

-- 25 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 26 --

-- 23 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 24 --

-- 21 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 22 --

-- 19 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 20 --

-- 17 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 18 --

-- 15 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 16 --

-- 13 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 14 --

-- 11 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 12 --

-- 9 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 10 --

-- 7 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 8 --

-- 5 SPARE 20 A 1 -- -- -- 0 3 -- -- -- -- -- -- 6 --

3 LIGHTING 20 A 1 0.18 3 -- -- -- -- -- -- 4 --

1 TELECOM ROOM REC. 20 A 1 0.54 3 3 30 A L21-30R RACK 2

K E Y

CKT

NO. LOAD DESCRIPTION

OCPD

AMPS P

WIRE

SIZE

H N G

A B C

WIRE

SIZE

G N H

OCPD

P AMPS LOAD DESCRIPTION

CKT

NO.

K E Y

NOTES:

SCCR: 30 kA

LOCATION: WIRE: 4

FED FROM: 0 A/0P @ GROUND BUS PHASE: 3

ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye

MOUNTING: SURFACE MAIN: 100 A MCB

PANEL B405IT-1-CR

CIRCUIT KEY NOTES:

*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.

TOTAL ESTIMATED DEMAND AMPS: 18.9 A

TOTAL CONNECTED AMPS: 26.97 A

Receptacles 0.54 kVA 70.00% 0.378 kVA TOTAL ESTIMATED DEMAND LOAD: 6.802 kVA

Power 9 kVA 70.00% 6.3 kVA TOTAL CONNECTED LOAD: 9.72 kVA

Lighting 0.178 kVA 70.00% 0.124 kVA

LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND

TOTALS*

LOAD SUMMARY

Total Amps: 29.73 26.71 25.00

Total Load: 3.54 kVA 3.18 kVA 3.00 kVA

-- 29 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 30 --

-- 27 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 28 --

-- 25 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 26 --

-- 23 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 24 --

-- 21 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 22 --

-- 19 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 20 --

-- 17 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 18 --

-- 15 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 16 --

-- 13 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 14 --

-- 11 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 12 --

-- 9 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 10 --

-- 7 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 8 --

-- 5 SPARE 20 A 1 -- -- -- 0 3 -- -- -- -- -- -- 6 --

3 LIGHTING 20 A 1 0.18 3 -- -- -- -- -- -- 4 --

1 TELECOM ROOM REC. 20 A 1 0.54 3 3 30 A L21-30R RACK 2

K E Y

CKT

NO. LOAD DESCRIPTION

OCPD

AMPS P

WIRE

SIZE

H N G

A B C

WIRE

SIZE

G N H

OCPD

P AMPS LOAD DESCRIPTION

CKT

NO.

K E Y

NOTES:

SCCR: 10 kA

LOCATION: WIRE: 4

FED FROM: 0 A/0P @ GROUND BUS PHASE: 3

ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye

MOUNTING: SURFACE MAIN: 100 A MCB

PANEL B405IT-3-CR

CIRCUIT KEY NOTES:

*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.

TOTAL ESTIMATED DEMAND AMPS: 17.5 A

TOTAL CONNECTED AMPS: 24.98 A

TOTAL ESTIMATED DEMAND LOAD: 6.3 kVA

TOTAL CONNECTED LOAD: 9.00 kVA

Power 9 kVA 70.00% 6.3 kVA

LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND

TOTALS*

LOAD SUMMARY

Total Amps: 25.00 25.00 25.00

Total Load: 3.00 kVA 3.00 kVA 3.00 kVA

-- 41 EXISTING LOAD 20 A 1 -- -- -- 0 3 -- -- -- -- -- -- 42 --

-- 39 EXISTING LOAD 20 A 1 -- -- -- 0 3 -- -- -- -- -- -- 40 --

-- 37 EXISTING LOAD 20 A 1 -- -- -- 0 3 3 30 A L21-30R RACK 38

-- 35 EXISTING LOAD 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A EXISTING LOAD 36 --

-- 33 EXISTING LOAD 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A EXISTING LOAD 34 --

-- 31 EXISTING LOAD 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A EXISTING LOAD 32 --

-- 29 EXISTING LOAD 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A EXISTING LOAD 30 --

-- 27 EXISTING LOAD 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A EXISTING LOAD 28 --

-- 25 EXISTING LOAD 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A EXISTING LOAD 26 --

-- 23 EXISTING LOAD 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A EXISTING LOAD 24 --

-- 21 EXISTING LOAD 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A EXISTING LOAD 22 --

-- 19 EXISTING LOAD 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A EXISTING LOAD 20 --

-- 17 EXISTING LOAD 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A EXISTING LOAD 18 --

-- 15 EXISTING LOAD 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A EXISTING LOAD 16 --

-- 13 EXISTING LOAD 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A EXISTING LOAD 14 --

-- 11 EXISTING LOAD 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A EXISTING LOAD 12 --

-- 9 EXISTING LOAD 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A EXISTING LOAD 10 --

-- 7 EXISTING LOAD 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A EXISTING LOAD 8 --

-- 5 EXISTING LOAD 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A EXISTING LOAD 6 --

-- 3 EXISTING LOAD 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A EXISTING LOAD 4 --

-- 1 EXISTING LOAD 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A EXISTING LOAD 2 --

K E Y

CKT

NO. LOAD DESCRIPTION

OCPD

AMPS P

WIRE

SIZE

H N G

A B C

WIRE

SIZE

G N H

OCPD

P AMPS LOAD DESCRIPTION

CKT

NO.

K E Y

NOTES:

SCCR: 10 kA

LOCATION: WIRE: 4

FED FROM: 0 A/0P @ GROUND BUS PHASE: 3

ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye

MOUNTING: SURFACE MAIN: 100 A MCB

EXISTING PANEL NP-2-3

Revisions: Date:

MSB-208 MSB-208 MSB-208

1600 A

MAIN

SPACE AHU-1

SPACE ELEV.

SPACE

MP-1-2

MP-2-2

MP-3-2

SPACE WWHP-2

SPACE WWHP-3

SPACE

SPACE

M-1 SPARE

NP-2-3

B405IT-1

NEW

100A/3P

M-2

B405IT-3

NEW

100A/3P

TVSS

SPACE SPACE

NP-1-2

NP-2-2

NP-3-2

WWHP-4

WWHP-1

NP-1-1

NP-2-1

NP-3-1

MP-1-1

MP-2-1

MP-3-1

SWBD B405 MSB 208

1600A MCB, 120/208V, 3 PHASE, 4 WIRE

80A 3P

125A 3P

150A 3P

175A 3P

175A 3P

250A 3P

175A 3P

50A 3P

150A 3P

150A 3P

150A 3P

150A 3P

300A 3P

400A 3P

300A 3P

100A 3P

100A 3P

NEW 100A

3 POLE BREAKER

225A 3P

NEW 225A 3P

BREAKER

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :

B

IM

/2

V

A T o m a h

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-7

.B

.E

T

R

.r v t

/8

/2

:3

:1

P M

B405-EP401

ELECTRICAL SCHEDULES EHRM INFRASTRUCTURE

UPGRADES, TOMAH, WI

TOMAH, WI

676-21-700

B405

02/11/2022 GJL ASQ

16477

225 W WASHINGTON STREET

SUITE 2700 CHICAGO, IL 60606

312.294.0501 FAX: 312.294.0003

www.imegcorp.com # 21003227.00

FS - FUSED SWITCH

MX - MANUAL SWITCH

MS - MANUAL STARTER

SS - SOLID STATE

RV - REDUCED VOLTAGE AUTOXFMR

SW - 2 SPEED, 1 WINDING

TW - 2 SPEED, 2 WINDING

RE - REVERSING HL - HANDLE PADLOCK HASP

YD - WYE - DELTA S/N - INSULATED NEUTRAL ASSEMBLY SS - START-STOP PUSHBUTTON IN DOOR

FV - FULL VOLTAGE *TA - TWO CONVERTIBLE AUXILIARY CONTACTS EI - ELECTRICAL INTERLOCK (2)-N.O. & (2)-N.C.

STARTER TYPE: *RP - RED (RUN) PILOT LIGHT IN DOOR FA - 4-CONVERTIBLE AUXILIARY CONTACTS

*HA - HAND-OFF-AUTO IN DOOR GP - GREEN (OFF) PILOT LIGHT IN DOOR

CB - CIRCUIT BREAKER *EO - ELECTRONIC OVERLOAD (3 PHASE MOTORS) TS - 2 SPEED SELECTOR SWITCH IN DOOR

NF - NON-FUSED *CT - CONTROL TRANSFORMER, FUSED 120V TO - MELTING THERMAL OVERLOADS (1 PHASE)

FU - FUSED SA - STANDARD ACCESSORIES (INCLUDES * ITEMS) PF - PHASE LOSS PROTECTION (5 HP OR GREATER, 3 PHASE...

DISCONNECT TYPE: ACCESSORIES & OPTIONS

NOTE: ALL DISCONNECTS (EXCEPT MANUAL STARTERS) SHALL BE HEAVY DUTY TYPE.

DISCONNECT AND STARTER SCHEDULE

ITEM

DISCONNECT TYPE &

RATING

CIRCUIT

VOLTAGE POLES

STARTER

ENCLOSURE

REQUIRED ACCESSORIES

& OPTIONS COMMENTSTYPE RATING

NEMA

SIZE TYPE

DS-30R NFU 30 A 208 V 3 NEMA 1 FUSED AT ** AMPS

DS-30R NFU 30 A 208 V 3 NEMA 1 FUSED AT ** AMPS

DS-30R NFU 30 A 208 V 3 NEMA 1 FUSED AT ** AMPS

CIRCUIT KEY NOTES:

*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.

TOTAL ESTIMATED DEMAND AMPS: 0 A

TOTAL CONNECTED AMPS: 0.00 A

TOTAL ESTIMATED DEMAND LOAD: 0 kVA

TOTAL CONNECTED LOAD: 0.00 kVA

LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND

TOTALS*

LOAD SUMMARY

Total Amps: 0.00 0.00 0.00

Total Load: 0.00 kVA 0.00 kVA 0.00 kVA

-- 41 SPACE -- -- -- -- -- 0 0 -- -- -- -- -- SPACE 42 --

-- 39 SPACE -- -- -- -- -- 0 0 -- -- -- -- -- SPACE 40 --

-- 37 SPACE -- -- -- -- -- 0 0 -- -- -- -- -- SPACE 38 --

-- 35 SPACE -- -- -- -- -- 0 0 -- -- -- -- -- SPACE 36 --

-- 33 SPACE -- -- -- -- -- 0 0 -- -- -- -- -- SPACE 34 --

-- 31 SPACE -- -- -- -- -- 0 0 -- -- -- -- -- SPACE 32 --

-- 29 SPACE -- -- -- -- -- 0 0 -- -- -- 1 20 A SPARE 30 --

-- 27 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 28 --

-- 25 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 26 --

-- 23 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A LEGIONILLA: CNT CAB, RCPT 24 --

-- 21 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 22 --

-- 19 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 20 --

-- 17 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A UH-1, AHU 18 --

-- 15 LS-1-2 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 16 --

-- 13 LS-1-1 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 14 --

-- 11 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A CUH-9, UH-3, UH-4, FCU-8 12 --

-- 9 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 10 --

-- 7 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A UH-3, UH-4, FCU-5, CUH-8 8 --

-- 5 CP-1, EF-3 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A CU-1, FCU-4 6 --

-- 3 WH-2 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A ESG SHUNT TRIP 4 --

-- 1 WH-1 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A 5150B CONTROL PANELS 2 --

K E Y

CKT

NO. LOAD DESCRIPTION

OCPD

AMPS P

WIRE

SIZE

H N G

A B C

WIRE

SIZE

G N H

OCPD

P AMPS LOAD DESCRIPTION

CKT

NO.

K E Y

NOTES:

ISC UNKNOWN 0.00 kA

SCCR: 65 kA

LOCATION: WIRE: 4

FED FROM: 0 A/0P @ GROUND BUS PHASE: 3

ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye

MOUNTING: SURFACE MAIN: 100 A MCB

PANEL B405-MP-1-1

Revisions: Date:

CIRCUIT KEY NOTES:

*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.

TOTAL ESTIMATED DEMAND AMPS: 8.7 A

TOTAL CONNECTED AMPS: 12.49 A

TOTAL ESTIMATED DEMAND LOAD: 3.15 kVA

TOTAL CONNECTED LOAD: 4.50 kVA

Power 4.5 kVA 70.00% 3.15 kVA

LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND

TOTALS*

LOAD SUMMARY

Total Amps: 12.50 12.50 12.50

Total Load: 1.50 kVA 1.50 kVA 1.50 kVA

41 42

39 40

37 38

35 36

33 34

31 32

29 30

27 28

25 26

23 24

21 22

19 20

17 18

15 16

13 14

-- 11 -- -- -- -- -- -- 0.75 12

9 CU B405-3.1 30 A 2 0.75 10

-- 7 -- -- -- -- -- -- 0.75 8

5 CU B405-2.1 30 A 2 0.75 6

-- 3 -- -- -- -- -- -- 0.75 4

1 CU B405-1.1 30 A 2 0.75 2

K E Y

CKT

NO. LOAD DESCRIPTION

OCPD

AMPS P

WIRE

SIZE

H N G

A B C

WIRE

SIZE

G N H

OCPD

P AMPS LOAD DESCRIPTION

CKT

NO.

K E Y

NOTES:

SCCR: 22 kA

LOCATION: WIRE: 4

FED FROM: 0 A/0P @ GROUND BUS PHASE: 3

ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye

MOUNTING: SURFACE MAIN: 200 A MCB

EXISTING PANEL B405-CR-1

B405-ATS-208-CR

6C13

1615A

1615C

6C17

1646B

16481 A

1647 1649 1658 1675

1640A 1640 1640B 1646 S22 1672

1615B

S24

406E8A

C

1647A

1653 1654

406E8

1617A

1631A

A1

B406-EP200

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :

B

IM

/2

V

A T o m a h

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-7

.B

.E

T

R

.r v t

/8

/2

:3

:2

P M

B406-ED111

FIRST FLOOR DEMOLITION -

ELECTRICAL

EHRM INFRASTRUCTURE

UPGRADES, TOMAH, WI

TOMAH, WI

676-700

B406

02/11/2022 GJL ASQ

16477

225 W WASHINGTON STREET

SUITE 2700 CHICAGO, IL 60606

312.294.0501 FAX: 312.294.0003

www.imegcorp.com # 21003227.00

N O R

HT

1/8" = 1'-0"

FIRST FLOOR DEMOLITION - ELECTRICAL

DN. 20-R.

2607 2608

S24

6C21

6C23

2629A

2633A

6C25

2634A

2603A

2604A

6C22

26202621

2632 2640 2646 2648 S22 2674

2631 2633 2645 2649

6C28

2659A

2658A

6C29

6C27

2644A

F

B406-EP200

CP-3-2

NP-1-2

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :

B

IM

/2

V

A T o m a h

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-7

.B

.E

T

R

.r v t

/8

/2

:3

:2

P M

B406-ED112

SECOND FLOOR DEMOLITION -

ELECTRICAL

EHRM INFRASTRUCTURE

UPGRADES, TOMAH, WI

TOMAH, WI

676-700

B406

02/11/2022 GJL ASQ

16477

225 W WASHINGTON STREET

SUITE 2700 CHICAGO, IL 60606

312.294.0501 FAX: 312.294.0003

www.imegcorp.com # 21003227.00

N O R

HT

1/8" = 1'-0"

SECOND FLOOR DEMOLITION - ELECTRICAL

3644A

DN. 20-R.

UP 13-R.

DN. 20-R.

6C31

3601 36023600

3604A

3603A

6C32 S24 3632 3636 3638

3640 3642

36503650B 3650A

3654 3656 3658 S22 3678

6C38

3663A

3668A

3683 3684

6C37

6C39

3631 3633 3635 3637

3635A

6C33

3623 3622

3650C

B406-EP200

CP-3-3

NP-1-3

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :

B

IM

/2

V

A T o m a h

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-7

.B

.E

T

R

.r v t

/8

/2

:3

:3

P M

B406-ED113

THIRD FLOOR DEMOLITION -

ELECTRICAL

EHRM INFRASTRUCTURE

UPGRADES, TOMAH, WI

TOMAH, WI

676-700

B406

02/11/2022 GJL ASQ

16477

225 W WASHINGTON STREET

SUITE 2700 CHICAGO, IL 60606

312.294.0501 FAX: 312.294.0003

www.imegcorp.com # 21003227.00

N O R

HT

1/8" = 1'-0"

THIRD FLOOR DEMOLITION - ELECTRICAL

1 0 8' 16'4'

6C13

1615A

1615C

6C17

1646B

16481 A

1647 1649 1658 1675

1640A 1640 1640B 1646 S22 1672

1615B

S24

406E8A

C

1647A

1653 1654

406E8

1617A

1631A

E E E

TELECOM

TELECOM

B406-EP200

B406-EP200

B406-EP200

CU B406-1.1

CU B406-2.1

B406IT-1-9

WP

CU B406-3.1

B406IT-1-CR-11,13

B406IT-2-CR-11,13

B406IT-3-CR-11,13

DS-30R DS-30R

DS-30R

WP

WP

WP

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :

B

IM

/2

V

A T o m a h

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-7

.B

.E

T

R

.r v t

/8

/2

:3

:3

P M

B406-EP111

FIRST FLOOR - ELECTRICAL EHRM INFRASTRUCTURE

UPGRADES, TOMAH, WI

TOMAH, WI

676-700

B406

02/11/2022 GJL ASQ

16477

225 W WASHINGTON STREET

SUITE 2700 CHICAGO, IL 60606

312.294.0501 FAX: 312.294.0003

www.imegcorp.com # 21003227.00

KEYNOTES:

1. OUTDOOR UNIT TO POWER INDOOR UNIT.

PROVIDE 2#10 & 1#12 IN 1/2" CONDUIT.

COORDINATE EXACT LOCATION WITH M.C.

N O R

HT

1/8" = 1'-0"

FIRST FLOOR - ELECTRICAL

DN. 20-R.

2607 2608

S24

6C21

6C23

2629A

2633A

6C25

2634A

2603A

2604A

6C22

26202621

2632 2640 2646 2648 S22 2674

2631 2633 2645 2649

6C28

2659A

2658A

6C29

6C27

2644A

F

TELECOM

STAFF

RESTROOM

B406-EP200

B406-EP200

CP-3-2

NP-1-2

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :

B

IM

/2

V

A T o m a h

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-7

.B

.E

T

R

.r v t

/8

/2

:3

:3

P M

B406-EP112

SECOND FLOOR - ELECTRICAL EHRM INFRASTRUCTURE

UPGRADES, TOMAH, WI

TOMAH, WI

676-700

B406

02/11/2022 GJL ASQ

16477

225 W WASHINGTON STREET

SUITE 2700 CHICAGO, IL 60606

312.294.0501 FAX: 312.294.0003

www.imegcorp.com # 21003227.00

N O R

HT

1/8" = 1'-0"

SECOND FLOOR - ELECTRICAL

3644A

DN. 20-R.

UP 13-R.

DN. 20-R.

6C31

3601 36023600

3604A

3603A

6C32 S24 3632 3636 3638

3640 3642

36503650B 3650A

3654 3656 3658 S22 3678

6C38

3663A

3668A

3683 3684

6C37

6C39

3631 3633 3635 3637

3635A

6C33

3623 3622

3650C

DAY ROOM

OFFICE

STAFF

LOUNGE

CRASH

CART

LOBBY

TELECOM

B406-EP200

B406-EP200

CP-3-3

NP-1-3

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :

B

IM

/2

V

A T o m a h

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-7

.B

.E

T

R

.r v t

/8

/2

:3

:3

P M

B406-EP113

THIRD FLOOR - ELECTRICAL EHRM INFRASTRUCTURE

UPGRADES, TOMAH, WI

TOMAH, WI

676-700

B406

02/11/2022 GJL ASQ

16477

225 W WASHINGTON STREET

SUITE 2700 CHICAGO, IL 60606

312.294.0501 FAX: 312.294.0003

www.imegcorp.com # 21003227.00

N O R

HT

1/8" = 1'-0"

THIRD FLOOR - ELECTRICAL

406E8A

C

406E8

1640B 1644

E

1640B 1644

SD

2644A

SDF

2644A

D

E

E

36543650C

SD

1640B 1644

E

A1

E

F

3650C

E

B406-MD-208-CR

B406-MDP-480V

MD-480-CR

ECB-208-LS

ECB-480-EQ

ECB-208-CR

ATS-208-CR

B406-MD-208-CR

ATS-480EQ

ATS-208-LS

MD-208-LS

TELECOM

B406IT-1-1

42"

B406IT-1-CR-1

42"

B406IT-1-1

42"

B406IT-1-CR-1

42" B406IT-1-1

42"

B406IT-1-CR-1

42"

B406IT-1SSAC B406-1.1

B406IT-1-CR-3,5,7

B406IT-1-3,5,7

7 6

B406IT-1-CR

TELECOM

A

B406IT-1

b

A

B406IT-1-CR

a ab

TELECOM

A

B406IT-2

b

A

B406IT-2-CR

a ab

TELECOM

B406IT-2-1

42"

B406IT-2-CR-1

42"

B406IT-2-CR-1

42"

B406IT-2-CR-1

42"

B406IT-2-1

42"

B406IT-2-1

42"

B406IT-2 SSAC B406-2.1

B406IT-2-CR-3,5,7

B406IT-2-3,5,7

4 5

7 6

B406IT-2-CR

TELECOM

B406IT-3-CR-1

42"

B406IT-3-1

42"

B406IT-3-CR-1

42"

B406IT-3-1

42"

B406IT-3-CR-1

42"

B406IT-3-1

42"

B406IT-3

SSAC B406-3.1

B406IT-3-CR-3,5,7

B406IT-3-3,5,7

4 5

7 6

B406IT-3-CR

TELECOM

A

B406IT-3

b

A

B406IT-3-CR

a ab

(E)UH

(E)UH

(E)UH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :

B

IM

/2

V

A T o m a h

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-7

.B

.E

T

R

.r v t

/2

/2

:4

:4

P

M

B406-EP200

ELECTRICAL ENLARGED PLANS EHRM INFRASTRUCTURE

UPGRADES, TOMAH, WI

TOMAH, WI

676-700

B406

02/11/2022 GJL ASQ

16477

225 W WASHINGTON STREET

SUITE 2700 CHICAGO, IL 60606

312.294.0501 FAX: 312.294.0003

www.imegcorp.com # 21003227.00

N O R

HT

1/4" = 1'-0"

FIRST FLOOR - ELECTRICAL

POWER - ELECTRICAL ROOM

N O R

HT

1/4" = 1'-0"

FIRST FLOOR - ELECTRICAL

POWER - TR-406-1-1

N O R

HT

1/4" = 1'-0"

FIRST FLOOR - ELECTRICAL

LIGHTING & FIRE ALARM -

TR-406-1-1

N O R

HT

1/4" = 1'-0"

SECOND FLOOR - ELECTRICAL

LIGHTING & FIRE ALARM -

TR-406-2-1

N O R

HT

1/4" = 1'-0"

SECOND FLOOR - ELECTRICAL

POWER - TR-406-2-1

N O R

HT

1/4" = 1'-0"

THIRD FLOOR - ELECTRICAL

POWER - TR-406-3-1

N O R

HT

1/4" = 1'-0"

THIRD FLOOR - ELECTRICAL

LIGHTING & FIRE ALARM -

TR-406-3-1

KEYNOTES:

1. INDOOR UNIT TO BE POWERED BY OUTDOOR

UNIT. PROVIDE SWITCH & 120V CONNECTION

FOR CONDENSATE PUMP ASSOCIATED WITH

FAN UNIT FROM FAN UNIT POWER.

COORDINATE EXACT LOCATION WITH M.C.

2. CONNECT SMOKE DETECTOR TO NEAREST

EXISTING SLC.

3. DISCONNECT AND REMOVE LIGHTS AND

RECEPTACLES IN AREA OF NEW IT ROOM.

MAINTAIN CIRCUIT CONTINUITY TO ADJOINING

SPACES.

4. COORDINATE FINAL LOCATION OF

RECEPTACLE L21-30R WITH TELECOM

CONTRACTOR. PROVIDE 3/4"C-4#10, 1#12 GND

TO PANEL FOR EACH RECEPTACLE.

5. PROVIDE EATON BLADEUPS, 5KW, 120/208V, 3-

PHASE, 4-WIRE RACK MOUNTED UPS FOR

EACH RACK TOWER.

6. PROVIDE APC#AP8861 RPDU RACK PDU 2G

WITH L21-20P CORD. (120/208V, 3-PHASE, 20A,

ZERO U, 5.7 KW, 208V, (36) C13 (6) C19 (2) 5-20R

OUTLETS. PROVIDE TWO PER RACK, MOUNTED

PER MANUFACTURER'S REQUIREMENTS.

7. PROVIDE ONE RACK MOUNTED ZONE PDU

UNIT. 30 AMP 3 PHASE, 120/208V, 5-WIRE WITH

(4) L21-30R, (6) 5-20R AND TWO 10' POWER

CORDS. ZONIT#ZPDS-208V-30A-L21-4L21-20R-

CR.

N O R

HT

1/4" = 1'-0"

FIRST FLOOR - ELECTRICAL

DEMOLITION

N O R

HT

1/4" = 1'-0"

SECOND FLOOR - ELECTRICAL

DEMOLITION

N O R

HT

1/4" = 1'-0"

THIRD FLOOR - ELECTRICAL

DEMOLITION

CONSTRUCTION NOTES:

1. REFER TO TECHNOLOGY PLANS FOR IT ROOM

LAYOUT AND RACK LAYOUT/DETAILS.

2. REFER TO SHEET E003 DETAIL FOR LAYOUT &

ONE-LINE OF RACK.

0 4' 8'2' 0 4' 8'2' 0 4' 8'2'

0 4' 8'2' 0 4' 8'2' 0 4' 8'2'

0 4' 8'2'

0 4' 8'2' 0 4' 8'2' 0 4' 8'2'

B406IT-1-CR

4#3 & 1#8 GND. IN 1 1/4" C.

B406-MD-208CR

SECOND FLOOR

THIRD FLOOR

ROOF

B406IT-2-CR

4#3 & 1#8 GND. IN 1 1/4" C.

B406IT-3-CR

4#3 & 1#8 GND. IN 1 1/4" C.

B406IT-1

4#3 & 1#8 GND. IN 1 1/4" C.

B406-MSB-208

B406IT-2

B406IT-3

4#3 & 1#8 GND. IN 1 1/4" C.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :

B

IM

/2

V

A T o m a h

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-7

.B

.E

T

R

.r v t

/8

/2

:3

:3

P M

B406-EP300

ELECTRICAL ONE-LINE DIAGRAMS EHRM INFRASTRUCTURE

UPGRADES, TOMAH, WI

TOMAH, WI

676-700

B406

02/11/2022 GJL ASQ

16477

225 W WASHINGTON STREET

SUITE 2700 CHICAGO, IL 60606

312.294.0501 FAX: 312.294.0003

www.imegcorp.com # 21003227.00

NO SCALE

PARTIAL POWER RISER

KEYNOTES:

1. PROVIDE NEW 100A/3P BREAKERS TO MATCH

EXISTING TYPE AND AIC RATING.

CP-1-G

BLDG 446

CP-3-2

CP-3-3

CP-1-1

B406-MD-208CR

600A, 120/208V, 3 PHASE, 4 WIRE

SPARE

CP-1-B150A

3P

225A 3P

225A 3P

CP-2-1CP-1-2

CP-1-3

CP-2-2

CP-2-3

100A 3P

100A 3P

CP-1-1 225A

3P

CP-4-2

CP-4-3

225A 3P

EM-1-G

100A

3P

225A 3P

300A 3P

300A 3P

B406IT-1-CR

100A

3P

B406IT-2-CR

100A

3P

B406-IT-3-CR

100A

3P

NEW 100A/3P BREAKERS.

NP-2-2

NP-2-3

B406-MSB-208

1200A, 120/208V, 3 PHASE, 4 WIRE

NP-1-2

NP-1-3

400A 3P

250A 3P

SPACE

ATS-208

-LS

250A 3P

SPARE

250A 3P

B406IT-1100A

3P

B406IT-2100A

3P

B406-IT-3100A

3P

NEW 100A/3P BREAKERS.

SPACE

400A

3PSPARE

400A

3PSPARE

400A

3PSPARE

400A

3PSPARE

SPACE

SPACE

CHAPEL

MECH.

RM

250A 3P

NP-3-G250A

3P

NP-2-1250A

3P

NP-3-1250A

3P

SPACE

1200A

MAIN

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :

B

IM

/2

V

A T o m a h

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-7

.B

.E

T

R

.r v t

/8

/2

:3

:3

P M

B406-EP301

ELECTRICAL ONE-LINE DIAGRAMS EHRM INFRASTRUCTURE

UPGRADES, TOMAH, WI

TOMAH, WI

676-700

B406

02/11/2022 GJL ASQ

16477

225 W WASHINGTON STREET

SUITE 2700 CHICAGO, IL 60606

312.294.0501 FAX: 312.294.0003

www.imegcorp.com # 21003227.00

NO SCALE

ELEVATION OF SWITCHBOARD - CRITICAL

1 NO SCALE

ELEVATION OF SWITCHBOARD - NORMAL

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :

B

IM

/2

V

A T o m a h

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-7

.B

.E

T

R

.r v t

/8

/2

:3

:4

P M

B406-EP400

ELECTRICAL SCHEDULES EHRM INFRASTRUCTURE

UPGRADES, TOMAH, WI

TOMAH, WI

676-700

B406

02/11/2022 GJL ASQ

16477

225 W WASHINGTON STREET

SUITE 2700 CHICAGO, IL 60606

312.294.0501 FAX: 312.294.0003

www.imegcorp.com # 21003227.00

CIRCUIT KEY NOTES:

*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.

TOTAL ESTIMATED DEMAND AMPS: 19.6 A

TOTAL CONNECTED AMPS: 27.97 A

Receptacles 0.9 kVA 70.00% 0.63 kVA TOTAL ESTIMATED DEMAND LOAD: 7.054 kVA

Power 9 kVA 70.00% 6.3 kVA TOTAL CONNECTED LOAD: 10.08 kVA

Lighting 0.178 kVA 70.00% 0.124 kVA

LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND

TOTALS*

LOAD SUMMARY

Total Amps: 31.00 26.50 26.48

Total Load: 3.72 kVA 3.18 kVA 3.18 kVA

-- 29 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 30 --

-- 27 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 28 --

-- 25 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 26 --

-- 23 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 24 --

-- 21 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 22 --

-- 19 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 20 --

-- 17 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 18 --

-- 15 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 16 --

-- 13 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 14 --

11 LIGHTING 20 A 1 0.18 0 -- -- -- 1 20 A SPARE 12 --

9 CU GFI REC. 20 A 1 0.18 0 -- -- -- 1 20 A SPARE 10 --

-- 7 -- -- -- -- -- -- 3 0 -- -- -- 1 20 A SPARE 8 --

-- 5 -- -- -- -- -- -- 3 0 -- -- -- 1 20 A SPARE 6 --

3 L21-30R RACK 30 A 3 3 0 -- -- -- 1 20 A SPARE 4 --

1 TELECOM ROOM REC. 20 A 1 0.72 0 -- -- -- 1 20 A SPARE 2 --

K E Y

CKT

NO. LOAD DESCRIPTION

OCPD

AMPS P

WIRE

SIZE

H N G

A B C

WIRE

SIZE

G N H

OCPD

P AMPS LOAD DESCRIPTION

CKT

NO.

K E Y

NOTES:

SCCR: 10 kA

LOCATION: TELECOM 1644 WIRE: 4

FED FROM: 0 A/0P @ B406-MD-208-CR GROUND BUS PHASE: 3

ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye

MOUNTING: SURFACE MAIN: 100 A MCB

PANEL B406IT-1

CIRCUIT KEY NOTES:

*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.

TOTAL ESTIMATED DEMAND AMPS: 18.9 A

TOTAL CONNECTED AMPS: 26.97 A

Receptacles 0.54 kVA 70.00% 0.378 kVA TOTAL ESTIMATED DEMAND LOAD: 6.802 kVA

Power 9 kVA 70.00% 6.3 kVA TOTAL CONNECTED LOAD: 9.72 kVA

Lighting 0.178 kVA 70.00% 0.124 kVA

LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND

TOTALS*

LOAD SUMMARY

Total Amps: 29.73 26.71 25.00

Total Load: 3.54 kVA 3.18 kVA 3.00 kVA

-- 29 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 30 --

-- 27 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 28 --

-- 25 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 26 --

-- 23 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 24 --

-- 21 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 22 --

-- 19 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 20 --

-- 17 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 18 --

-- 15 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 16 --

-- 13 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 14 --

-- 11 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 12 --

9 LIGHTING 20 A 1 0.18 0 -- -- -- 1 20 A SPARE 10 --

-- 7 -- -- -- -- -- -- 3 0 -- -- -- 1 20 A SPARE 8 --

-- 5 -- -- -- -- -- -- 3 0 -- -- -- 1 20 A SPARE 6 --

3 L21-30R RACK 30 A 3 3 0 -- -- -- 1 20 A SPARE 4 --

1 TELECOM ROOM REC. 20 A 1 0.54 0 -- -- -- 1 20 A SPARE 2 --

K E Y

CKT

NO. LOAD DESCRIPTION

OCPD

AMPS P

WIRE

SIZE

H N G

A B C

WIRE

SIZE

G N H

OCPD

P AMPS LOAD DESCRIPTION

CKT

NO.

K E Y

NOTES:

SCCR: 10 kA

LOCATION: TELECOM 2642 WIRE: 4

FED FROM: 0 A/0P @ B406-MD-208-CR GROUND BUS PHASE: 3

ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye

MOUNTING: SURFACE MAIN: 100 A MCB

PANEL B406IT-2

CIRCUIT KEY NOTES:

*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.

TOTAL ESTIMATED DEMAND AMPS: 18.9 A

TOTAL CONNECTED AMPS: 26.97 A

Receptacles 0.54 kVA 70.00% 0.378 kVA TOTAL ESTIMATED DEMAND LOAD: 6.802 kVA

Power 9 kVA 70.00% 6.3 kVA TOTAL CONNECTED LOAD: 9.72 kVA

Lighting 0.178 kVA 70.00% 0.124 kVA

LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND

TOTALS*

LOAD SUMMARY

Total Amps: 29.73 26.71 25.00

Total Load: 3.54 kVA 3.18 kVA 3.00 kVA

-- 29 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 30 --

-- 27 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 28 --

-- 25 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 26 --

-- 23 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 24 --

-- 21 SPACE -- -- -- -- -- 0 0 -- -- -- 1 20 A SPARE 22 --

-- 19 SPACE -- -- -- -- -- 0 0 -- -- -- 1 20 A SPARE 20 --

-- 17 SPACE -- -- -- -- -- 0 0 -- -- -- 1 20 A SPARE 18 --

-- 15 SPACE -- -- -- -- -- 0 0 -- -- -- 1 20 A SPARE 16 --

-- 13 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 14 --

-- 11 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 12 --

9 LIGHTING 20 A 1 0.18 0 -- -- -- 1 20 A SPARE 10 --

-- 7 -- -- -- -- -- -- 3 0 -- -- -- 1 20 A SPARE 8 --

-- 5 -- -- -- -- -- -- 3 0 -- -- -- 1 20 A SPARE 6 --

3 L21-30R RACK 30 A 3 3 0 -- -- -- 1 20 A SPARE 4 --

1 TELECOM ROOM REC. 20 A 1 0.54 0 -- -- -- 1 20 A SPARE 2 --

K E Y

CKT

NO. LOAD DESCRIPTION

OCPD

AMPS P

WIRE

SIZE

H N G

A B C

WIRE

SIZE

G N H

OCPD

P AMPS LOAD DESCRIPTION

CKT

NO.

K E Y

NOTES:

SCCR: 10 kA

LOCATION: TELECOM 3652 WIRE: 4

FED FROM: 0 A/0P @ B406-MD-208-CR GROUND BUS PHASE: 3

ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye

MOUNTING: SURFACE MAIN: 100 A MCB

PANEL B406IT-3

CIRCUIT KEY NOTES:

*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.

TOTAL ESTIMATED DEMAND... 21.8 A

TOTAL CONNECTED AMPS: 31.14 A

Receptacles 0.54 kVA 70.00% 0.378 kVA TOTAL ESTIMATED DEMAND... 7.852 kVA

Power 10.5 kVA 70.00% 7.35 kVA TOTAL CONNECTED LOAD: 11.22 kVA

Lighting 0.178 kVA 70.00% 0.124 kVA

LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND

TOTALS*

LOAD SUMMARY

Total Amps: 36.48 26.48 31.98

Total Load: 4.29 kVA 3.18 kVA 3.75 kVA

-- 29 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 30 --

-- 27 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 28 --

-- 25 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 26 --

-- 23 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 24 --

-- 21 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 22 --

-- 19 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 20 --

-- 17 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 18 --

-- 15 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 16 --

-- 13 -- -- -- -- -- -- 0.75 0 -- -- -- 1 20 A SPARE 14 --

11 CU B406-1.1 30 A 2 0.75 0 -- -- -- 1 20 A SPARE 12 --

9 LIGHTING 20 A 1 0.18 0 -- -- -- 1 20 A SPARE 10 --

-- 7 -- -- -- -- -- -- 3 0 -- -- -- 1 20 A SPARE 8 --

-- 5 -- -- -- -- -- -- 3 0 -- -- -- 1 20 A SPARE 6 --

3 L21-30R RACK 30 A 3 3 0 -- -- -- 1 20 A SPARE 4 --

1 TELECOM ROOM REC. 20 A 1 0.54 0 -- -- -- 1 20 A SPARE 2 --

K E Y

CKT

NO. LOAD DESCRIPTION

OCPD

AMPS P

WIRE

SIZE

H N G

A B C

WIRE

SIZE

G N H

OCPD

P AMPS LOAD DESCRIPTION

CKT

NO.

K E Y

NOTES:

KVA RATING: SCCR: 10 kA

LOCATION: TELECOM 1644 WIRE: 4

FED FROM: 0 A/0P @ GROUND BUS PHASE: 3

ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye

MOUNTING: SURFACE MAIN: 100 A MCB

PANEL B406IT-1-CR

CIRCUIT KEY NOTES:

*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.

TOTAL ESTIMATED DEMAND... 21.8 A

TOTAL CONNECTED AMPS: 31.14 A

Receptacles 0.54 kVA 70.00% 0.378 kVA TOTAL ESTIMATED DEMAND... 7.852 kVA

Power 10.5 kVA 70.00% 7.35 kVA TOTAL CONNECTED LOAD: 11.22 kVA

Lighting 0.178 kVA 70.00% 0.124 kVA

LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND

TOTALS*

LOAD SUMMARY

Total Amps: 36.48 26.48 31.98

Total Load: 4.29 kVA 3.18 kVA 3.75 kVA

-- 29 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 30 --

-- 27 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 28 --

-- 25 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 26 --

-- 23 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 24 --

-- 21 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 22 --

-- 19 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 20 --

-- 17 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 18 --

-- 15 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 16 --

-- 13 -- -- -- -- -- -- 0.75 0 -- -- -- 1 20 A SPARE 14 --

11 CU B406-2.1 30 A 2 0.75 0 -- -- -- 1 20 A SPARE 12 --

9 LIGHTING 20 A 1 0.18 0 -- -- -- 1 20 A SPARE 10 --

-- 7 -- -- -- -- -- -- 3 0 -- -- -- 1 20 A SPARE 8 --

-- 5 -- -- -- -- -- -- 3 0 -- -- -- 1 20 A SPARE 6 --

3 L21-30R RACK 30 A 3 3 0 -- -- -- 1 20 A SPARE 4 --

1 TELECOM ROOM REC. 20 A 1 0.54 0 -- -- -- 1 20 A SPARE 2 --

K E Y

CKT

NO. LOAD DESCRIPTION

OCPD

AMPS P

WIRE

SIZE

H N G

A B C

WIRE

SIZE

G N H

OCPD

P AMPS LOAD DESCRIPTION

CKT

NO.

K E Y

NOTES:

KVA RATING: SCCR: 10 kA

LOCATION: TELECOM 2642 WIRE: 4

FED FROM: 0 A/0P @ GROUND BUS PHASE: 3

ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye

MOUNTING: SURFACE MAIN: 100 A MCB

PANEL B406IT-2-CR

CIRCUIT KEY NOTES:

*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.

TOTAL ESTIMATED DEMAND... 21.8 A

TOTAL CONNECTED AMPS: 31.14 A

Receptacles 0.54 kVA 70.00% 0.378 kVA TOTAL ESTIMATED DEMAND... 7.852 kVA

Power 10.5 kVA 70.00% 7.35 kVA TOTAL CONNECTED LOAD: 11.22 kVA

Lighting 0.178 kVA 70.00% 0.124 kVA

LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND

TOTALS*

LOAD SUMMARY

Total Amps: 36.48 26.48 31.98

Total Load: 4.29 kVA 3.18 kVA 3.75 kVA

-- 29 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 30 --

-- 27 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 28 --

-- 25 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 26 --

-- 23 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 24 --

-- 21 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 22 --

-- 19 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 20 --

-- 17 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 18 --

-- 15 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 16 --

-- 13 -- -- -- -- -- -- 0.75 0 -- -- -- 1 20 A SPARE 14 --

11 CU B406-3.1 30 A 2 0.75 0 -- -- -- 1 20 A SPARE 12 --

9 LIGHTING 20 A 1 0.18 0 -- -- -- 1 20 A SPARE 10 --

-- 7 -- -- -- -- -- -- 3 0 -- -- -- 1 20 A SPARE 8 --

-- 5 -- -- -- -- -- -- 3 0 -- -- -- 1 20 A SPARE 6 --

3 L21-30R RACK 30 A 3 3 0 -- -- -- 1 20 A SPARE 4 --

1 TELECOM ROOM REC. 20 A 1 0.54 0 -- -- -- 1 20 A SPARE 2 --

K E Y

CKT

NO. LOAD DESCRIPTION

OCPD

AMPS P

WIRE

SIZE

H N G

A B C

WIRE

SIZE

G N H

OCPD

P AMPS LOAD DESCRIPTION

CKT

NO.

K E Y

NOTES:

KVA RATING: SCCR: 10 kA

LOCATION: TELECOM 3652 WIRE: 4

FED FROM: 0 A/0P @ GROUND BUS PHASE: 3

ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye

MOUNTING: SURFACE MAIN: 100 A MCB

PANEL B406IT-3-CR

FS - FUSED SWITCH

MX - MANUAL SWITCH

MS - MANUAL STARTER

SS - SOLID STATE

RV - REDUCED VOLTAGE AUTOXFMR

SW - 2 SPEED, 1 WINDING

TW - 2 SPEED, 2 WINDING

RE - REVERSING HL - HANDLE PADLOCK HASP

YD - WYE - DELTA S/N - INSULATED NEUTRAL ASSEMBLY SS - START-STOP PUSHBUTTON IN DOOR

FV - FULL VOLTAGE *TA - TWO CONVERTIBLE AUXILIARY CONTACTS EI - ELECTRICAL INTERLOCK (2)-N.O. & (2)-N.C.

STARTER TYPE: *RP - RED (RUN) PILOT LIGHT IN DOOR FA - 4-CONVERTIBLE AUXILIARY CONTACTS

*HA - HAND-OFF-AUTO IN DOOR GP - GREEN (OFF) PILOT LIGHT IN DOOR

CB - CIRCUIT BREAKER *EO - ELECTRONIC OVERLOAD (3 PHASE MOTORS) TS - 2 SPEED SELECTOR SWITCH IN DOOR

NF - NON-FUSED *CT - CONTROL TRANSFORMER, FUSED 120V TO - MELTING THERMAL OVERLOADS (1 PHASE)

FU - FUSED SA - STANDARD ACCESSORIES (INCLUDES * ITEMS) PF - PHASE LOSS PROTECTION (5 HP OR GREATER, 3 PHASE...

DISCONNECT TYPE: ACCESSORIES & OPTIONS

NOTE: ALL DISCONNECTS (EXCEPT MANUAL STARTERS) SHALL BE HEAVY DUTY TYPE.

DISCONNECT AND STARTER SCHEDULE

ITEM

DISCONNECT TYPE &

RATING

CIRCUIT

VOLTAGE POLES

STARTER

ENCLOSURE

REQUIRED ACCESSORIES

& OPTIONS COMMENTSTYPE RATING

NEMA

SIZE TYPE

DS-30R NFU 30 A 208 V 3 NEMA 1 FUSED AT ** AMPS

DS-30R NFU 30 A 208 V 3 NEMA 1 FUSED AT ** AMPS

DS-30R NFU 30 A 208 V 3 NEMA 1 FUSED AT ** AMPS

Revisions: Date:

B406-MSB-208

B406-MD-208-CR B406-MD-208-CR B406-MD-208-CR

B406-MSB-208 B406-MSB-208

1701 1700

1701A

2110A

S5

1742C

1742B

B

1742A

1722C 1708

1724A

1722A 1722B

1739 1741 1743 1767 1769 1786 1799

S6 1742 1750A 1766 1768 1770 1772 S4…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .