Atch 13 - Telecommunications 2 of 4.pdf
PDF 14 MB Posted
- Attached to
- Y1AZ--EHRM Infrastructure Upgrades Construction - Tomah Federal contract opportunity
- Solicitation number
- 36C77622B0031
About this file
This federal contract opportunity solicitation involves infrastructure upgrades and renovations at the Tomah VA Medical Center in Wisconsin. The solicitation seeks contractors to perform electrical, HVAC, communication, physical security, and fiber infrastructure upgrades across multiple buildings on campus. Additional requirements include modifying impacted roads, walks, grading and drainage, hazardous material abatement, and data center WAN updates. The solicitation was issued by the Department of Veterans Affairs Technology Acquisition Center located in Austin, Texas.
View the file
Other files for this federal contract opportunity
Show all 42
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
3128A
3126A
3124A
3119 3119A
3117A
3111A
3109A
3107A
3105A
3137A
3137 3139
3139A
3149 3148
3151 3153
3146 3154
3161 3163 3165
3190A 3190
3189A
3187A
3185A
3184A
31823182A
3178A
3176A
31743174A
3172A
3142 3144
3100 3170
1C39
C
1C371C33
1C32
1C34
C
3150A
3150B
C
S32 S30
31663131
3147A
1C35
1D-WAP
4D
4D
4D
4D
4D
4D
1D-WAP
1D-WAP
D
4D
4D
4D
1D-GWAP
4D
4D 4D
4D
D
4D
4D 4D
4D
4D
4D
4D
4D
4D
4D
4D
4D
4D
4D
D
D
4D
D
1D-WAP
1D-WAP1D-CAM
1D-CAM
1D-GWAP
1D-GWAP
1D-WAP
1D-GWAP
1D-CAM
D
D
D
4D
D
D
1D-WAP
D
4D
D
4D
4D
4D
D
4D 4D
D
1D-WAP
D
1D-WAP
D
D
4D
4D 4D 4D
D
4D
4D
1D-WAP
1D-WAP
1D-CAM
1D-CAM
1D-CAM
1V
1D-WAP
D
4D
4D
4D
4D
1D-WAP
1D-GWAP
4D
4D
1D-WAP
4D
4D
4D
4D
4D 4D
4D 4D
4D
D
4D
1D-WAP
1D-CAM
4D
4D
4D
4D
4D
4D
1D-GWAP
1D-WAP
4D
4D
4D
4D
D
D
4D
D
D
1D-WAP
1D-CAM
4D
4D
4D
1D-WAP
4D
4D
4D
1D-WAP
D
1D-WAP
D
D
D
1D-WAP
4D
1D-GWAP
4D
4D
4D
1D-GWAP 1D-WAP
4D
4D
1D-WAP
4D
1D-CAM
1D-WAP
1D-CAM
2D
B401-TN302
B401-TN302
EXISTING TR-401-3-1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :
B
IM
/2
V
A T o m a h
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-7
.B
.E
T
R
.r v t
/7
/2
:2
:3
P M
B401-TD103
THIRD FLOOR DEMOLITION -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES, TOMAH, WI
TOMAH, WI
676-700
B401
02/11/2022 PDN JFK
16477
N O R
HT
1/8" = 1'-0"
THIRD FLOOR DEMOLITION - TELECOMMUNICATIONS
225 W WASHINGTON STREET
SUITE 2700 CHICAGO, IL 60606
312.294.0501 FAX: 312.294.0003
www.imegcorp.com # 21003227.00
TECHNOLOGY SHEET NOTES:
1. REFER TO TN000 TECHNOLOGY COVERSHEET
FOR TECHNOLOGY SYMBOL LIST.
2. ALL INFORMATION OUTLETS ON THIS SHEET
SERVED FROM EXISTING TR-401-3-1.
3. ALL EXISTING INFORMATION OUTLETS,
CONDUITS AND BACKBOXES TO REMAIN.
EXISTING CABLING TO BE REMOVED FROM
END TO END AND REPLACED WITH NEW DATA
CABLES. REFER TO B401-TN103 FOR MORE
INFORMATION.
KEYNOTES:
1. EXISTING BACKBONE AND HORIZONTAL
COPPER AND FIBER TO BE COMPLETELY
REMOVED FROM END TO END AFTER
COMPLETION OF ALL NEW CABLING.
0 8' 16'4'
Revisions: Date:
BASEMENT
BA100
UP
JUNCTION BOX
(1) 4" CONDUIT - (3) B LEG FIBERS
(1) 4" CONDUIT - SPARE
TO FIRST FLOOR TR-401-1-1
(1) 4" CONDUIT - (3) A LEG FIBERS
(1) 4" CONDUIT - (10) 25-PAIR CAT 5E
(1) 4" CONDUIT - SPARE
TO FIRST FLOOR TR-401-1-1
LOCATION OF TR-401-1-1
ON FIRST FLOOR
JUNCTION BOX
SC-HH-1
(3) 4" SLEEVES
SC-HH-1
(1) 4" CONDUIT - (3) B LEG FIBERS
(1) 4" CONDUIT - SPARE
1 2
(1) 4" CONDUIT - (3) A LEG FIBERS
(1) 4" CONDUIT - (10) 25-PAIR CAT 5E
(1) 4" CONDUIT - SPARE
(2) 4" SLEEVES
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :
B
IM
/2
V
A T o m a h
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-7
.B
.E
T
R
.r v t
/7
/2
:2
:3
P M
B401-TN100
BASEMENT FLOOR -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES, TOMAH, WI
TOMAH, WI
676-700
B401
02/11/2022 PDN JFK
16477
225 W WASHINGTON STREET
SUITE 2700 CHICAGO, IL 60606
312.294.0501 FAX: 312.294.0003
www.imegcorp.com # 21003227.00
N O R
HT
1/8" = 1'-0"
BASEMENT FLOOR - TELECOMMUNICATIONS
TECHNOLOGY SHEET NOTES:
1. REFER TO TN000 TECHNOLOGY COVERSHEET
FOR TECHNOLOGY GENERAL NOTES,
TECHNOLOGY INSTALLATION NOTES AND
SYMBOL LIST.
2. REFER TO TN600 FOR GENERAL TECHNOLOGY
EQUIPMENT SCHEDULE.
3. CONTRACTOR TO FIELD VERIFY CONDUIT
ROUTES AND COORDINATE WITH OWNER
PRIOR TO INSTALLATION.
KEYNOTES:
1. PROVIDE SC-HH-1 5' FROM EXTERIOR WALL.
REFER TO 1/TN401 EXTERIOR HAND HOLE
DETAIL FOR ADDITIONAL INFORMATION.
2. (2) 4" CONDUITS PROVIDED BY OTHERS.
COORDINATE WITH CIVIL DRAWINGS.
3. REFER TO 3/TN401 EXTERIOR WALL
PENETRATION DETAIL FOR ADDITIONAL
INFORMATION.
4. CONTRACTOR TO PROVIDED PULL BOX SIZED
PER CODE REQUIREMENT.
ELEVELEV
1113A
1143AA 1143 1143B
1165A
1143A
1144S12 1146
1150A
1166 S10
1184A 1184B
1C19
1116 1118
1120A
1182A 1182B
1C171C151C13
1145A
DN.
UP UP
1D-GWAP
1D-GWAP
2D 2D 4D
1D-WAP
D
D
D
D
D
D
D
4D
D
D
D
D
D
D
D
1D-WAP
D
D
4D
4D
1D-WAP
D
1D-WAP
3D
3D
1D-WAP
1D-WAP
1D-WAP
D
1D-WAP
D
1D-WAP
D
D
D
2D
1D-WAP
1D-CAM
1D-CAM
2D
D
1D-WAP
1D-WAP
D
D
1D-WAP
1D
1D
D
1D-WAP
D
1D-WAP
1D
2D
2D 4D
D
1D-CAM
1D-WAP
1D-WAP
D
1D-WAP
1D-WAP
1D-TV
1D-CAM
D
-C A
M
D
-C A
M
1D-CAM
4D
4D
1D
4D
D
D
D
2D
D
D
4D
D
D
D
D
2D
1D-CAM
1D
1D-WAP
1D-WAP
1D-WAP
W
P
CSS
1D-CAM
1D-CAM
OFFICE
130 SF
1164A
TELECOM
B401-TN300
TR-401-1-1
B401-TN300
EXISTING TR-401-1-1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :
B
IM
/2
V
A T o m a h
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-7
.B
.E
T
R
.r v t
/7
/2
:2
:3
P M
B401-TN101
FIRST FLOOR -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES, TOMAH, WI
TOMAH, WI
676-700
B401
02/11/2022 PDN JFK
16477
N O R
HT
1/8" = 1'-0"
FIRST FLOOR - TELECOMMUNICATIONS
225 W WASHINGTON STREET
SUITE 2700 CHICAGO, IL 60606
312.294.0501 FAX: 312.294.0003
www.imegcorp.com # 21003227.00
TECHNOLOGY SHEET NOTES:
1. REFER TO TN000 TECHNOLOGY COVERSHEET
FOR TECHNOLOGY GENERAL NOTES,
TECHNOLOGY INSTALLATION NOTES AND
SYMBOL LIST.
2. ALL INFORMATION OUTLETS ON THIS SHEET
SHALL BE SERVED FROM TR-401-1-1.
3. REFER TO TN600 FOR GENERAL TECHNOLOGY
EQUIPMENT SCHEDULE.
4. CONTRACTOR TO INCLUDE AN ALLOWANCE
FOR 10 ADDITIONAL 2-PORTS CAT 6A
INFORMATION OUTLETS IN THEIR PROPOSAL
FOR THIS SHEET. FUTURE INFORMATION
OUTLET LOCATIONS WILL BE DETERMINED BY
THE VA AT A LATER DATE.
5. CONTRACTOR TO FIELD VERIFY CONDUIT
RISER ROUTE WITH OWNER PRIOR TO
INSTALLATION.
6. ALL INFORMATION OUTLETS ON THIS SHEET
TO BE CABLED ON A SCHEDULED BASIS WITH
OWNER WHILE OCCUPIED WITH STAFF AND
PATIENTS. COORDINATE DEMO AND CABLE
REPLACEMENT WITH OWNER. REFER TO
SHEET B401-TD101 FOR MORE INFORMATION.
7. CONTRACTOR TO PROVIDE NEW J-HOOK
ROUTES FOR ALL NEW CABLING. J-HOOK SIZE
AND QUANTITY TO BE PER MANUFACTURER
RECOMMENDATIONS.
UP
DN
UP
2128A
2126A
2124A
2119A
2117A
2111A
2109A
2107A
2105A
2137A
2137 2139
2139A
2149 2148
2151 2153
2146 2154
2161 2163 2165
2190A 2190
2189A
2187 2187A
2185A
2184A
2182A
2178A
2176A
2174A
21722172A
2140 2142 2144
2100 2170
C
1C21
1C23
C
1C24
C
2150A
2150B
C
S22
EXST STAIR
S20
21662131
1C22A
C
B
C
B
1C25 1C27
C
B
1C28A
C
B
C
A
C
A
1D-GWAP
1D-GWAP
1D-GWAP
1D-GWAP
1D-GWAP
1D-GWAP
1D-GWAP
1D-GWAP
1D-GWAP
1D-GWAP
1D-WAP
1D-WAP
1D-WAP
4D
4D
4D
4D
4D
4D
1D-WAP
1D-WAP
D
4D
4D
4D
4D
4D
1D-WAP
4D
D
4D
4D 4D
4D
4D
4D
4D
4D
4D
4D
4D
4D
4D
4D
4D
4D
D
4D
D
1D-WAP
1D-WAP
1D-CAM
1D-CAM
1D-WAP
1D-CAM
D
D
D 4
D
D
D
1D-WAP
D
4D 4D
D
4D
4D
1D-WAP
4D
D
4D 4D
D
1D-WAP
D 4 D
1D-WAP
4D
4D 4D 4D
D
4D
4D
D
1D
1D-WAP 1D-WAP
1D-CAM
1D-CAM
1D-CAM
1D-CAM
D
D
1D
1D-WAP
1D-WAP
D
4D
4D
4D
4D
1D-WAP
4D
4D
1D-WAP
4D
4D
4D
4D
4D 4D
4D 4D
4D
D
4D
1D-WAP
1D-CAM
4D
4D
4D
4D
4D
1D-WAP
4D
4D
4D
4D
D
D
4D
D
D
1D-WAP
1D-CAM
1D-WAP
4D
4D
1D-CAM
TR-401-2-1
B401-TN301
B401-TN301
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :
B
IM
/2
V
A T o m a h
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-7
.B
.E
T
R
.r v t
/7
/2
:2
:3
P M
B401-TN102
SECOND FLOOR -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES, TOMAH, WI
TOMAH, WI
676-700
B401
02/11/2022 PDN JFK
16477
N O R
HT
1/8" = 1'-0"
SECOND FLOOR - TELECOMMUNICATIONS
225 W WASHINGTON STREET
SUITE 2700 CHICAGO, IL 60606
312.294.0501 FAX: 312.294.0003
www.imegcorp.com # 21003227.00
TECHNOLOGY SHEET NOTES:
1. REFER TO TN000 TECHNOLOGY COVERSHEET
FOR TECHNOLOGY GENERAL NOTES,
TECHNOLOGY INSTALLATION NOTES AND
SYMBOL LIST.
2. ALL INFORMATION OUTLETS ON THIS SHEET
SHALL BE SERVED FROM TR-401-2-1.
3. REFER TO TN600 FOR GENERAL TECHNOLOGY
EQUIPMENT SCHEDULE.
4. CONTRACTOR TO INCLUDE AN ALLOWANCE
FOR 10 ADDITIONAL CAT 6A INFORMATION
OUTLETS IN THEIR PROPOSAL FOR THIS
SHEET. FUTURE INFORMATION OUTLET
LOCATIONS WILL BE DETERMINED BY THE VA
AT A LATER DATE.
5. CONTRACTOR TO FIELD VERIFY CONDUIT
RISER ROUTE WITH OWNER PRIOR TO
INSTALLATION.
6. ALL INFORMATION OUTLETS ON THIS SHEET
TO BE CABLED ON A SCHEDULED BASIS WITH
OWNER WHILE OCCUPIED WITH STAFF AND
PATIENTS. COORDINATE DEMO AND CABLE
REPLACEMENT WITH OWNER. REFER TO
SHEET B401-TD102 FOR MORE INFORMATION.
7. CONTRACTOR TO PROVIDE NEW J-HOOK
ROUTES FOR ALL NEW CABLING. J-HOOK SIZE
AND QUANTITY TO BE PER MANUFACTURER
RECOMMENDATIONS.
3128A
3126A
3124A
3119 3119A
3117A
3111A
3109A
3107A
3105A
3137A
3137 3139
3139A
3149 3148
3151 3153
3146 3154
3161 3163 3165
3190A 3190
3189A
3187A
3185A
3184A
31823182A
3178A
3176A
31743174A
3172A
3142 3144
3100 3170
1C39
C
1C371C33
1C32
1C34
C
3150A
3150B
C
S32 S30
31663131
3147A
1C35
1D-GWAP
1D-GWAP
1D-GWAP
1D-GWAP
1D-GWAP
1D-GWAP
1D-GWAP
1D-GWAP
1D-WAP
4D
4D
4D
4D
4D
4D
1D-WAP
1D-WAP
D
4D
4D
4D
4D
4D 4D
4D
D
4D
4D 4D
4D
4D
4D
4D
4D
4D
4D
4D
4D
4D
4D
D
D
4D
D
1D-WAP
1D-WAP1D-CAM
1D-CAM
1D-WAP
1D-CAM
D
D
D
4D
D
D
1D-WAP
D
4D
D
4D
4D
4D
D
4D 4D
D
1D-WAP
D
4D
4D 4D 4D
D
4D
4D
1D-WAP
1D-WAP
1D-CAM
1D-CAM
1D-CAM
4D
4D
4D
1D-WAP
4D
4D
4D
1D-WAP
D
1D-WAP
D
D
D
1D-WAP
4D
1D-WAP
D
4D
4D
4D
4D
1D-WAP
4D
4D
1D-WAP
4D
4D
4D
4D
4D 4D
4D 4D
4D
D
4D
1D-WAP
1D-CAM
4D
4D
4D
4D
4D
4D
1D-WAP
4D
4D
4D
4D
D
D
4D
D
D
1D-WAP
1D-CAM
4D
4D
4D
1D-WAP
4D
4D
1D-WAP
4D
1D-CAM
D
1D-WAP
D
D
1D
1D-WAP
2D
1D-CAM
TR-401-3-1
B401-TN302
B401-TN302
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :
B
IM
/2
V
A T o m a h
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-7
.B
.E
T
R
.r v t
/7
/2
:2
:3
P M
B401-TN103
THIRD FLOOR -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES, TOMAH, WI
TOMAH, WI
676-700
B401
02/11/2022 PDN JFK
16477
N O R
HT
1/8" = 1'-0"
THIRD FLOOR - TELECOMMUNICATIONS
225 W WASHINGTON STREET
SUITE 2700 CHICAGO, IL 60606
312.294.0501 FAX: 312.294.0003
www.imegcorp.com # 21003227.00
TECHNOLOGY SHEET NOTES:
1. REFER TO TN000 TECHNOLOGY COVERSHEET
FOR TECHNOLOGY GENERAL NOTES,
TECHNOLOGY INSTALLATION NOTES AND
SYMBOL LIST.
2. ALL INFORMATION OUTLETS ON THIS SHEET
SHALL BE SERVED FROM TR-401-3-1.
3. REFER TO TN600 FOR GENERAL TECHNOLOGY
EQUIPMENT SCHEDULE.
4. CONTRACTOR TO INCLUDE AN ALLOWANCE
FOR 10 ADDITIONAL CAT 6A INFORMATION
OUTLETS IN THEIR PROPOSAL FOR THIS
SHEET. FUTURE INFORMATION OUTLET
LOCATIONS WILL BE DETERMINED BY THE VA
AT A LATER DATE.
5. CONTRACTOR TO FIELD VERIFY CONDUIT
RISER ROUTE WITH OWNER PRIOR TO
INSTALLATION.
6. ALL INFORMATION OUTLETS ON THIS SHEET
TO BE CABLED ON A SCHEDULED BASIS WITH
OWNER WHILE OCCUPIED WITH STAFF AND
PATIENTS. COORDINATE DEMO AND CABLE
REPLACEMENT WITH OWNER. REFER TO
SHEET B401-TD103 FOR MORE INFORMATION.
7. CONTRACTOR TO PROVIDE NEW J-HOOK
ROUTES FOR ALL NEW CABLING. J-HOOK SIZE
AND QUANTITY TO BE PER MANUFACTURER
RECOMMENDATIONS.
1D-CAM
1D-CAM
SC-FDC-1
SC-MPP-1
P T
Z
C C
T V
SC-MPP-2
OWNER
PROVIDED
NETWORK
EQUIPMENT
SC-MPP-2
SC-FDC-1 SC-MPP-1
SC-FDC-1
SC-BET
B -T
N
EXISTING WIRE MANAGER
(TYP.)
EXISTING EQUIPMENT
RACK
SC-FDC-1
SC-MPP-1
EXISTING WIRE MANAGER (TYP.)
EXISTING EQUIPMENT RACK
24 STRAND SM FIBER FROM
TR-401-1-1
NOTES:
1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES OF MATERIALS SHOWN. THIS RISER IS SHOWN FOR CLARIFICATION OF CONNECTION(S), LOCATIONS AND CABLE TYPE. ALL INFORMATION OUTLETS ARE TYPICAL OF THE OUTLETS IN THE AREA SHOWN. REFER TO FLOOR PLANS FOR MORE SPECIFIC ROUTING INFORMATION. REFER TO SPECIFICATIONS FOR
ADDITIONAL REQUIREMENTS.
2. REFER TO TN600 FOR TECHNOLOGY EQUIPMENT SCHEDULE.
KEYNOTES:
1. CONTRACTOR TO PROVIDE (2) FIBER OPTIC PATCH CORDS FOR CONNECTIVITY TO OWNER EQUIPMENT.
2. CONTRACTOR TO PROVIDE (6) CAT 6A PATCH CORDS FOR CONNECTIVITY TO OWNER EQUIPMENT.
EXISTING TR-401-1-1
24 CAT 6A COPPER CABLES
FROM TR-401-1-1
TO OWNER PROVIDED
EQUIPMENT
TO OWNER PROVIDED
EQUIPMENT
B401-TN300
SC-ER-1
SC-VWM-1
(TYP.)
SC-GND-1
(TYP.)
AC-SCP-1
AC-PSP-1 2
CAM 1
01-01
SC-CT-2
(TYP.)
PW-CPW-1
(3) 4" C FROM BASEMENT (2) 4" C FROM BASEMENT
18"x6"
18"x6"
"x
"x
18"x6"
SC-BET
(TYPICAL OF 5)
SC-ER-1 SC-VWM-1
(TYP.)
SC-FDC-1
SC-BLK-1
SC-MPP-2
SC-MPP-2
SC-MPP-2
SC-MPP-2
SC-MPP-2
SC-MPP-2
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-HWM-1
SC-HWM-1
SC-HWM-2
SC-HWM-2
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-HWM-2
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-HWM-1
SC-HWM-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-MPP-1
SC-MPP-2
SC-BLK-1
SC-FDC-1
SC-BLK-1
(TYP.)
NETWORK SWITCH
NETWORK SWITCH
NETWORK SWITCH
NETWORK SWITCH
NETWORK SWITCH
PDU
UPS UPS
3 3
24 STRAND SM FIBER FROM
BUILDING 32 (LEG A)
(10) CAT 5E 25-PAIRS COPPER
CABLES FROM BUILDING 32
NOTES:
1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES OF MATERIALS SHOWN.
THIS RISER IS SHOWN FOR CLARIFICATION OF CONNECTION(S), LOCATIONS AND CABLE TYPE. ALL INFORMATION OUTLETS ARE TYPICAL OF THE OUTLETS IN THE AREA SHOWN. REFER TO FLOOR PLANS FOR MORE SPECIFIC ROUTING INFORMATION. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
2. REFER TO TN600 FOR TECHNOLOGY EQUIPMENT SCHEDULE.
KEYNOTES:
1. #D INDICATES VOICE/DATA FACEPLATE CONFIGURATION. REFER TO INFORMATION OUTLET SCHEDULE ON
TN600 FOR ADDITIONAL INFORMATION. REFER TO TECHNOLOGY FLOOR PLANS AND TECHNOLOGY
EQUIPMENT SCHEDULE FOR ADDITIONAL INFORMATION.
2. FIBER OPTIC PATCH CORDS. REFER TO SPECIFICATIONS.
3. 24 GAUGE, CAT 6A UTP CABLE. REFER TO SPECIFICATIONS.
4. RJ-45 TO RJ-45 CATEGORY 6A UTP PATCH CORDS. REFER TO SPECIFICATIONS FOR PATCH CORD
REQUIREMENTS.
5. CONTRACTOR SHALL TERMINATE 1 PAIR PER PORT, USING PINS 4 AND 5.
6. PROVIDE CAT 6A CABLE FOR CAMERA. TERMINATE CAT 6A CABLE WITH RJ-45 PLUG.
7. LIGHTNING PROTECTION. REFER TO 6/B401-TN300 FOR LOCATION.
8. (2) CAT 5E 25-PAIR CABLES FROM LIGHTNING PROTECTION.
#D-WAP
#D
#D-CAM
24 STRAND SM FIBER FROM
BUILDING 32 (LEG B)
TR-401-1-1
24 STRAND SM FIBER TO
EXISTING TR-401-1-1
REFER TO B401-TD101 FOR
EXACT LOCATION.
(24) CAT 6A CABLES TO
EXISTING TR-401-1-1
REFER TO B401-TD101 FOR
EXACT LOCATION.
PTZ
CCTV
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :
B
IM
/2
V
A T o m a h
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-7
.B
.E
T
R
.r v t
/7
/2
:2
:3
P M
B401-TN300
TELECOMMUNICATIONS ROOM
ENLARGEMENTS
EHRM INFRASTRUCTURE
UPGRADES, TOMAH, WI
TOMAH, WI
676-700
B401
02/11/2022 PDN JFK
16477
225 W WASHINGTON STREET
SUITE 2700 CHICAGO, IL 60606
312.294.0501 FAX: 312.294.0003
www.imegcorp.com # 21003227.00
N O R
HT
1/4" = 1'-0"
DATA ROOM ENLARGEMENT - EXISTING TR-401-1-1
N O R
HT
1/4" = 1'-0"
LADDER RACK LAYOUT - EXISTING TR-401-1-1
1" = 1'-0"
DATA RACK ELEVATION - EXISTING TR-401-1-1
NO SCALE
CONNECTIVITY RISER DIAGRAM - EXISTING TR-401-1-1
NOTES:
1. REFER TO 2/B401-TN300 FOR LADDER RACK LAYOUT - EXISTING TR-401-1-1.
2. REFER TO 4/B401-TN300 FOR CONNECTIVITY RISER DIAGRAM - EXISTING TR-401-1-1.
3. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.
NOTES:
1. REFER TO 4/B401-TN300 FOR CONNECTIVITY RISER DIAGRAM - EXISTING TR-401-1-1.
2. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.
KEYNOTES:
1. CONTRACTOR TO REMOVE RACK MOUNTED DEVICES AND RETURN TO OWNER.
N O R
HT
1/4" = 1'-0"
DATA ROOM ENLARGEMENT - TR-401-1-1
N O R
HT
1/4" = 1'-0"
LADDER RACK LAYOUT - TR-401-1-1
NOTES:
1. REFER TO 6/B401-TN300 FOR LADDER RACK LAYOUT - TR-401-1-1.
2. REFER TO 8/B401-TN300 FOR CONNECTIVITY RISER DIAGRAM - TR-401-1-1.
3. REFER TO AE211 FOR PLYWOOD INFORMATION.
4. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.
KEYNOTES:
1. REFER TO 1/T400 BONDING BUS BAR DETAIL FOR ADDITIONAL INFORMATION.
2. CONTRACTOR TO COORDINATE FINAL RACK LOCATION WITH OWNER PRIOR TO
INSTALLATION.
3. CONTRACTOR TO COORDINATE FINAL LOCATION AND FIELD OF VIEW WITH OWNER PRIOR TO
INSTALLATION.
1" = 1'-0"
DATA RACK ELEVATION - TR-401-1-1
NO SCALE
CONNECTIVITY RISER DIAGRAM - TR-401-1-1
NOTES:
1. REFER TO 8/B401-TN300 FOR CONNECTIVITY RISER DIAGRAM - TR-401-1-1.
2. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.
KEYNOTES:
1. DEDICATED FIBER PANEL FOR 24 STRAND SM FIBER TO EXISTING TR-401-1-1.
2. DEDICATED PATCH PANEL FOR 24 CAT 6A CABLES TO EXISTING TR-401-1-1.
3. UPS AND PDU’S PROVIDED AND INSTALLED BY THE E.C. REFER TO ELECTRICAL
DRAWINGS FOR MORE INFORMATION.
NOTES:
1. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.
2. INSTALL BASKET TRAY AT 7'6" AFF.
3. REFER TO 2/B401-TN400 TECHNOLOGY CONDUIT RISER DIAGRAM FOR ADDITIONAL
INFORMATION.
4. REFER TO TN503 CONDUIT AND CABLE PATHWAY DIAGRAMS FOR ADDITIONAL
INFORMATION.
KEYNOTES:
1. CONTRACTOR TO COORDINATE FINAL LOCATION FOR LIGHTNING PROTECTION
ENCLOSURE WITH OWNER PRIOR TO INSTALLATION.
0 4' 8'2'
0 4' 8'2'
0 4' 8'2'
0 4' 8'2'
1D-CAM 1D-CAM
P T
Z
C C
T V
SC-MPP-2
OWNER
PROVIDED
NETWORK
EQUIPMENT
SC-MPP-2
SC-FDC-1
SC-BET
EXISTING WALLRACK
EXISTING
GROUND BAR
EXISTING CABINET
B -T
N
EXISTING WIRE MANAGER (TYP.)
EXISTING EQUIPMENT RACK (TYP.)
EXISTING LADDER
RACK (TYP.)
EXISTING CONDUITS
EXT. EQUIPMENT
EXT. WIRE MANAGER
EXT. PATCH PANEL
EXT. PATCH PANEL
EXT. PATCH PANEL
EXT. PATCH PANEL
EXT. WIRE MANAGER
EXT. WIRE MANAGER
EXISTING WIRE MANAGER
(TYP.)
EXISTING EQUIPMENT RACK
(TYP.) 1
B -T
N
EXISTING WALLRACK
EXISTING
GROUND BAR
EXISTING CABINET
SC-VWM-1
SC-ER-1(TYP.)
(TYP.)
CM-1
02-01
SC-CT-2
(TYP.)
EXISTING CONDUITS
(2) 4" C FROM
FIRST FLOOR SC-LR-1
(TYP.)
18"x6"
"x
18"x6"
"x
"x
SC-ER-1
(TYP.)
SC-FDC-1
SC-BLK-1
SC-MPP-2
SC-MPP-2
SC-MPP-2
SC-MPP-2
SC-MPP-2
SC-MPP-2
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-MPP-2
SC-MPP-2
SC-MPP-2
SC-MPP-2
SC-MPP-2
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-HWM-1 SC-HWM-1
SC-HWM-2 SC-HWM-2
SC-HWM-2
SC-HWM-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-HWM-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
NETWORK SWITCH
NETWORK SWITCH
NETWORK SWITCH
NETWORK SWITCH
NETWORK SWITCH
PDU
UPS
UPS
SC-VWM-1
(TYP.)
24 STRAND SM FIBER FROM
BUILDING 32 (LEG A)
NOTES:
1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES OF MATERIALS SHOWN.
THIS RISER IS SHOWN FOR CLARIFICATION OF CONNECTION(S), LOCATIONS AND CABLE TYPE. ALL INFORMATION OUTLETS ARE TYPICAL OF THE OUTLETS IN THE AREA SHOWN. REFER TO FLOOR PLANS FOR MORE SPECIFIC ROUTING INFORMATION. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
2. REFER TO TN600 FOR TECHNOLOGY EQUIPMENT SCHEDULE.
KEYNOTES:
1. #D INDICATES VOICE/DATA FACEPLATE CONFIGURATION. REFER TO INFORMATION OUTLET SCHEDULE ON
TN600 FOR ADDITIONAL INFORMATION. REFER TO TECHNOLOGY FLOOR PLANS AND TECHNOLOGY
EQUIPMENT SCHEDULE FOR ADDITIONAL INFORMATION.
2. FIBER OPTIC PATCH CORDS. REFER TO SPECIFICATIONS.
3. 24 GAUGE, CAT 6A UTP CABLE. REFER TO SPECIFICATIONS.
4. RJ-45 TO RJ-45 CATEGORY 6A UTP PATCH CORDS. REFER TO SPECIFICATIONS FOR PATCH CORD
REQUIREMENTS.
5. CONTRACTOR SHALL TERMINATE 1 PAIR PER PORT, USING PINS 4 AND 5.
6. PROVIDE CAT 6A CABLE FOR CAMERA. TERMINATE CAT 6A CABLE WITH RJ-45 PLUG.
7. LIGHTNING PROTECTION. REFER TO 6/B401-TN300 FOR LOCATION.
8. (4) CAT 5E 25-PAIR CABLES FROM LIGHTNING PROTECTION.
24 STRAND SM FIBER FROM
BUILDING 32 (LEG B)
TR-401-2-1
(10) CAT 5E 25-PAIRS COPPER
CABLES FROM BUILDING 32
#D-WAP
#D
#D-CAM3
PTZ
CCTV
TR-401-1-1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :
B
IM
/2
V
A T o m a h
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-7
.B
.E
T
R
.r v t
/7
/2
:2
:4
P M
B401-TN301
TELECOMMUNICATIONS ROOM
ENLARGEMENTS
EHRM INFRASTRUCTURE
UPGRADES, TOMAH, WI
TOMAH, WI
676-700
B401
02/11/2022 PDN JFK
16477
225 W WASHINGTON STREET
SUITE 2700 CHICAGO, IL 60606
312.294.0501 FAX: 312.294.0003
www.imegcorp.com # 21003227.00
N O R
HT
1/4" = 1'-0"
DATA ROOM ENLARGEMENT - EXISTING TR-401-2-1
N O R
HT
1/4" = 1'-0"
LADDER RACK LAYOUT - EXISTING TR-401-2-1
1" = 1'-0"
DATA RACK ELEVATION - EXISTING TR-401-2-1
NOTES:
1. REFER TO 2/B401-TN301 FOR LADDER RACK LAYOUT - EXISTING TR-401-2-1.
2. REFER TO 4/B401-TN301 FOR CONNECTIVITY RISER DIAGRAM - EXISTING TR-401-2-1.
KEYNOTES:
1. REMOVE EXISTING PATCH PANELS FROM 2-POST RACK WITHOUT REMOVING HORIZONTAL CABLES. CONTRACTOR TO REMOVE EXISTING 2-POST RACKS. RACK MOUNTED DEVICES TO BE REMOVED AND PROTECTED FOR RE-INSTALLATION. EXISTING EQUIPMENT RACKS TO REMAIN UNTIL ALL RACK MOUNTED DEVICES RELOCATED TO NEW SC-ER-1.
KEYNOTES:
1. CONTRACTOR TO DEMO EXISTING RACK MOUNTED DEVICES AND RETURN TO OWNER.
N O R
HT
1/4" = 1'-0"
DATA ROOM ENLARGEMENT - TR-401-2-1
N O R
HT
1/4" = 1'-0"
LADDER RACK LAYOUT - TR-401-2-1
NOTES:
1. REFER TO 5/B401-TN301 FOR LADDER RACK LAYOUT - EXISTING TR-401-2-1.
2. REFER TO 7/B401-TN301 FOR CONNECTIVITY RISER DIAGRAM - EXISTING TR-401-2-1.
3. REFER TO AE211 FOR PLYWOOD INFORMATION.
4. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.
KEYNOTES:
1. CONTRACTOR TO COORDINATE FINAL RACK LOCATION WITH OWNER PRIOR TO INSTALLATION.
2. CONTRACTOR TO COORDINATE FINAL LOCATION AND FIELD OF VIEW WITH OWNER PRIOR TO
INSTALLATION.
1" = 1'-0"
DATA RACK ELEVATION - TR-401-2-1
NOTES:
1. REFER TO 7/B401-TN301 FOR CONNECTIVITY RISER DIAGRAM - TR-401-2-1.
2. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.
3. CONTRACTOR TO RE-INSTALL EXISTING RACK MOUNTED DEVICES IN SC-ER-1.
KEYNOTES:
1. UPS AND PDU’S PROVIDED AND INSTALLED BY THE E.C. REFER TO ELECTRICAL
DRAWINGS FOR MORE INFORMATION.
NO SCALE
CONNECTIVITY RISER DIAGRAM - TR-401-2-1
NOTES:
1. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.
2. INSTALL BASKET TRAY AT 7'6" AFF.
3. REFER TO 2/B401-TN400 TECHNOLOGY CONDUIT RISER DIAGRAM FOR ADDITIONAL
INFORMATION.
4. REFER TO TN503 CONDUIT AND CABLE PATHWAY DIAGRAMS FOR ADDITIONAL
INFORMATION.
0 4' 8'2' 0 4' 8'2'
0 4' 8'2'
0 4' 8'2'
P T
Z
C C
T V
SC-MPP-2
OWNER
PROVIDED
NETWORK
EQUIPMENT
SC-MPP-2
SC-FDC-1
SC-BET
EXISTING
GROUND BAR
EXISTING CABINETS
EXISTING WALLRACK
EXISTING CATV
HEADEND
B -T
N
EXISTING WIRE MANAGER (TYP.)
EXISTING EQUIPMENT RACK (TYP.) 1
EXISTING LADDER RACK
(TYP.)
EXISTING CONDUITS
EXISTING WIRE MANAGER (TYP.)
EXISTING EQUIPMENT RACK (TYP.)
B -T
N
EXISTING
GROUND BAR
EXISTING CABINETS
EXISTING WALLRACK
EXISTING CATV
HEADEND
SC-VWM-1
SC-ER-1 (TYP.)
(TYP.)
CM-1
03-01
SC-CT-2
(TYP.)
EXISTING CONDUITS
(2) 4" C FROM
SECOND FLOOR
18"x6"
"x
18"x6"
"x
"x
SC-VWM-1 SC-ER-1
(TYP.) (TYP.)
SC-FDC-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-MPP-2
SC-MPP-2
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-HWM-1 SC-HWM-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-HWM-2
SC-HWM-2
SC-HWM-1
SC-HWM-1
SC-HWM-2
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
NETWORK SWITCH
NETWORK SWITCH
NETWORK SWITCH
NETWORK SWITCH
NETWORK SWITCH
SC-MPP-2
SC-MPP-2
SC-MPP-2
SC-MPP-2
SC-MPP-2
SC-MPP-2
PDU
UPS UPS
SC-MPP-2
SC-MPP-2
SC-MPP-2
SC-MPP-2
1 1
24 STRAND SM FIBER FROM
BUILDING 32 (LEG A)
NOTES:
1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES OF MATERIALS SHOWN. THIS RISER IS SHOWN FOR CLARIFICATION OF CONNECTION(S), LOCATIONS AND CABLE TYPE. ALL INFORMATION OUTLETS ARE TYPICAL OF THE OUTLETS IN THE AREA SHOWN. REFER TO FLOOR PLANS FOR MORE SPECIFIC ROUTING INFORMATION. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
2. REFER TO TN600 FOR TECHNOLOGY EQUIPMENT SCHEDULE.
KEYNOTES:
1. #D INDICATES VOICE/DATA FACEPLATE CONFIGURATION. REFER TO INFORMATION OUTLET SCHEDULE ON
TN600 FOR ADDITIONAL INFORMATION. REFER TO TECHNOLOGY FLOOR PLANS AND TECHNOLOGY
EQUIPMENT SCHEDULE FOR ADDITIONAL INFORMATION.
2. FIBER OPTIC PATCH CORDS. REFER TO SPECIFICATIONS.
3. 24 GAUGE, CAT 6A UTP CABLE. REFER TO SPECIFICATIONS.
4. RJ-45 TO RJ-45 CATEGORY 6A UTP PATCH CORDS. REFER TO SPECIFICATIONS FOR PATCH CORD
REQUIREMENTS.
5. CONTRACTOR SHALL TERMINATE 1 PAIR PER PORT, USING PINS 4 AND 5.
6. PROVIDE CAT 6A CABLE FOR CAMERA. TERMINATE CAT 6A CABLE WITH RJ-45 PLUG.
7. LIGHTNING PROTECTION. REFER TO 6/B401-TN300 FOR LOCATION.
8. (4) CAT 5E 25-PAIR CABLES FROM LIGHTNING PROTECTION.
24 STRAND SM FIBER FROM
BUILDING 32 (LEG B)
TR-401-3-1
(10) CAT 5E 25-PAIRS COPPER
CABLES FROM BUILDING 32
#D-WAP
#D
#D-CAM3
PTZ
CCTV
TR-401-1-1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :
B
IM
/2
V
A T o m a h
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-7
.B
.E
T
R
.r v t
/7
/2
:2
:4
P M
B401-TN302
TELECOMMUNICATIONS ROOM
ENLARGEMENTS
EHRM INFRASTRUCTURE
UPGRADES, TOMAH, WI
TOMAH, WI
676-700
B401
02/11/2022 PDN JFK
16477
225 W WASHINGTON STREET
SUITE 2700 CHICAGO, IL 60606
312.294.0501 FAX: 312.294.0003
www.imegcorp.com # 21003227.00
N O R
HT
1/4" = 1'-0"
DATA ROOM ENLARGEMENT - EXISTING TR-401-3-1
N O R
HT
1/4" = 1'-0"
LADDER RACK LAYOUT - EXISTING TR-401-3-1
1" = 1'-0"
DATA RACK ELEVATION - EXISTING TR-401-3-1
NOTES:
1. REFER TO 2/B401-TN302 FOR LADDER RACK LAYOUT - EXISTING TR-401-3-1.
KEYNOTES:
1. REMOVE EXISTING PATCH PANELS FROM 2-POST RACK WITHOUT REMOVING HORIZONTAL CABLES. CONTRACTOR TO REMOVE EXISTING 2-POST RACKS. RACK MOUNTED DEVICES TO BE REMOVED AND PROTECTED FOR RE-INSTALLATION. EXISTING EQUIPMENT RACKS TO REMAIN UNTIL ALL RACK MOUNTED DEVICES RELOCATED TO NEW SC-ER-1.
KEYNOTES:
1. CONTRACTOR TO DEMO RACK MOUNTED DEVICES AND RETURN TO OWNER.
N O R
HT
1/4" = 1'-0"
DATA ROOM ENLARGEMENT - TR-401-3-1
N O R
HT
1/4" = 1'-0"
LADDER RACK LAYOUT - TR-401-3-1
NOTES:
1. REFER TO 5/B401-TN302 FOR LADDER RACK LAYOUT - TR-401-3-1.
2. REFER TO 7/B401-TN302 FOR CONNECTIVITY RISER DIAGRAM - TR-401-3-1.
3. REFER TO AE211 FOR PLYWOOD INFORMATION.
4. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.
KEYNOTES:
1. CONTRACTOR TO COORDINATE FINAL RACK LOCATION WITH OWNER PRIOR TO INSTALLATION.
2. CONTRACTOR TO COORDINATE FINAL LOCATION AND FIELD OF VIEW WITH OWNER PRIOR TO INSTALLATION.
1" = 1'-0"
DATA RACK ELEVATION - TR-401-3-1
NOTES:
1. REFER TO 7/B401-TN302 FOR CONNECTIVITY RISER DIAGRAM - TR-401-3-1.
2. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.
3. CONTRACTOR TO RE-INSTALL EXISTING RACK MOUNTED DEVICES IN SC-ER-1.
KEYNOTES:
1. UPS AND PDU’S PROVIDED AND INSTALLED BY THE E.C. REFER TO ELECTRICAL
DRAWINGS FOR MORE INFORMATION.
NO SCALE
CONNECTIVITY RISER DIAGRAM - TR-401-3-1
NOTES:
1. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.
2. INSTALL BASKET TRAY AT 7'6" AFF.
3. REFER TO 2/B401-TN400 TECHNOLOGY CONDUIT RISER DIAGRAM FOR ADDITIONAL
INFORMATION.
4. REFER TO TN503 CONDUIT AND CABLE PATHWAY DIAGRAMS FOR ADDITIONAL
INFORMATION.
0 4' 8'2' 0 4' 8'2'
0 4' 8'2'
SC-GND-1
EXISTING
GROUND BAR
EXISTING
GROUND BAR
CONDUCTOR
LENGTH IN FEET
BONDING CONDUCTOR SIZING SCHEDULE
MINIMUM ACCEPTABLE
SIZE - AWG
LESS THAN 13' 6
14' - 20' 4
21' - 26' 3
27' - 33' 2
34' - 41' 1
42' - 52' 1/0
53' - 66' 2/0
GREATER THAN 66' 3/0
ELECTRICAL ENTRANCE
INTERSYSTEM BONDING
TERMINATION
GROUNDING ELECTRODE
CONDUCTOR BY OTHERS
ELECTRICAL GROUNDING
ELECTRODE SYSTEM
EXISTING TELECOMMUNICATIONS BONDING BACKBONE
(TBB) (TYP)
FIRST
FLOOR
SECOND
FLOOR
THIRD
FLOOR
TR-401-1-1
TR-401-2-1
TR-401-3-1
NOTES:
1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES OF
MATERIALS. THIS RISER IS SHOWN FOR CLARIFICATION OF CONNECTION LOCATIONS AND
CONDUCTOR TYPE. ALL CONNECTIONS AND SYSTEM DEVICES SHOWN ARE TYPICAL AND NOT
REPRESENTATIVE OF ACTUAL PROJECT QUANTITIES. REFER TO FLOOR PLANS AND ENLARGED
FLOOR PLANS FOR ACTUAL QUANTITIES AND LOCATIONS OF DEVICES AND MORE SPECIFIC ROUTING
INFORMATION. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
2. ALL CONDUCTORS IN THE TECHNOLOGY BONDING SYSTEM SHALL BE MINIMUM SIZE OF 3/0 AWG
PLENUM RATED COPPER (GREEN OR MARKED WITH A DISTINCTIVE GREEN COLOR) UNLESS
CONDUCTOR LENGTH IS LESS THAN 66 FEET. REFER TO BONDING CONDUCTOR SIZING SCHEDULE
FOR SIZING CRITERIA FOR CONDUCTORS LESS THAN 66 FEET IN LENGTH. REFER TO
SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
3. ALL BONDING CONDUCTORS AND BONDING JUMPERS SHALL BE CONNECTED BY COMPRESSION
LUGS, EXOTHERMIC WELDING, OR IRREVERSIBLE COMPRESSION CONNECTORS. SOLDER IS NOT AN
ACCEPTABLE MEANS OF CONNECTION. SHEET METAL SCREWS SHALL NOT BE USED TO CONNECT
COMMUNICATIONS BONDING CONDUCTORS TO EQUIPMENT. WHERE NECESSARY, REMOVE PAINT
AND/OR USE PAINT-PIERCING WASHERS TO PROVIDE PROPER ELECTRICAL BOND AT ALL
CONNECTIONS.
4. REFER TO 2/TN400 FOR TYPICAL TELECOM ROOM BONDING FLOW DIAGRAM.
5. REFER TO TELECOM ROOM REFERENCES SCHEDULE ON DRAWING TN000 FOR
TELECOMMUNICATIONS ROOM NUMBER AND LOCATION INFORMATION.
KEYNOTES:
1. BONDING CONDUCTOR FOR TELECOMMUNICATIONS (BCT). BCT SHALL BE THE SAME SIZE AS THE TBB OR LARGER. REFER TO BONDING CONDUCTOR SIZING SCHEDULE FOR SIZING REQUIREMENTS.
FIRST
FLOOR
SECOND
FLOOR
THIRD
FLOOR
TR-401-1-1
TR-401-2-1
TR-401-3-1
BASEMENT
TO EXTERIOR
HANDHOLE
(1) 4" CONDUIT
(2) 4" C
(2) 4" C
EXISTING (2) 4" C
(1) 4" CONDUIT - (3) B LEG FIBERS
(1) 4" CONDUIT - SPARE
EXISTING (2) 4" C
JUNCTION BOX
(TYP.)
NOTES:
1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES OF MATERIALS SHOWN. THIS RISER IS SHOWN FOR CLARIFICATION OF CONNECTION(S), LOCATIONS AND CABLE TYPE. ALL INFORMATION OUTLETS ARE TYPICAL OF THE OUTLETS IN THE AREA SHOWN. REFER TO
FLOOR PLANS FOR MORE SPECIFIC ROUTING INFORMATION. REFER TO SPECIFICATIONS FOR
ADDITIONAL REQUIREMENTS.
2. REFER TO TN600 FOR TECHNOLOGY EQUIPMENT SCHEDULE.
3. REFER TO TN503 CONDUIT AND CABLE PATHWAY DIAGRAMS FOR ADDITIONAL INFORMATION.
(1) 4" CONDUIT -
(10) 25-PAIR CAT 5E
SC-BET
TO EXTERIOR
HANDHOLE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :
B
IM
/2
V
A T o m a h
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-7
.B
.E
T
R
.r v t
/7
/2
:2
:4
P M
B401-TN400
TELECOMMUNICATIONS DETAILS EHRM INFRASTRUCTURE
UPGRADES, TOMAH, WI
TOMAH, WI
676-700
B401
02/11/2022 PDN JFK
16477
225 W WASHINGTON STREET
SUITE 2700 CHICAGO, IL 60606
312.294.0501 FAX: 312.294.0003
www.imegcorp.com # 21003227.00
NO SCALE
TECHNOLOGY BONDING RISER DIAGRAM
1 NO SCALE
TECHNOLOGY CONDUIT RISER DIAGRAM
Revisions: Date:
INDIVIDUAL CAMERA REQUIREMENTS SCHEDULE
CAMERA #
CAMERA
TYPE FIELD OF VIEW DESCRIPTION
DETAIL
REFERENCE NOTES
01-01 CM-1 GENERAL VIEW
TELECOMMUNICATION ROOM
6/TN400
02-01 CM-1 GENERAL VIEW
TELECOMMUNICATION ROOM
6/TN400
03-01 CM-1 GENERAL VIEW
TELECOMMUNICATION ROOM
6/TN400
2. REFER TO SPECIFICATIONS SECTION 08 71 00 FOR DOOR HARDWARE SETS AS IT RELATES TO THIS SCHEDULE.
1. ELECTRONIC DOOR HARDWARE SUCH AS ELECTRIC STRIKES, ELECTRIC LATCH RETRACTION, ETC. SHALL BE PROVIDED AND INSTALLED BY OTHERS. REFER TO THE TECHNOLOGY EQUIPMENT SCHEDULE ON TN600 FOR CREDENTIAL READER TYPE INFORMATION.
GENERAL NOTES:
CONTROLLED SECURITY SCHEME (CSS) TYPE SCHEDULE
DOOR # R
O
U G
H -I
N O
N L
Y
CREDENTIAL
READER INTEGRATION
REQUEST TO
EXIT DOOR HARDWARE
OTHER (REFER TO
NOTES)
NOTESC
R
E D
E N
T
IA
L R
E A
D E
R T
Y P
E
M U
L T
IP
L
E C
R E
D E
N T
IA
L
R E
A D
E R
S O
P E
R A
T E
S S
IN
G
L E
D O
O R
O P
E R
A T
E S
M U
L T
IP
L
E D
O O
R S
W
IR
E L
E S
S
A U
T O
M A
T
IC
D O
O R
O P
E R
A T
O R
E L
E V
A T
O R
L O
C K
E D
B Y
E M
E R
G E
N C
Y D
U R
E S
S S
E Q
U E
N C
E
IN
F
A N
T P
R O
T E
C T
IO
N
R E
M O
T E
U N
L O
C K
V
IA
I N
T E
R C
O M
M A
S T
E R
R E
M O
T E
U N
L O
C K
V
IA
P U
S H
B U
T T
O N
IN
T
R U
S
IO
N D
E T
E C
T
IO
N
R E
M O
T E
U N
L O
C K
V
IA
F
IR
E C
O M
M A
N D
C E
N T
E R
V
ID
E O
S U
R V
E
IL
L A
N C
E
W A
N D
E R
P R
E V
E N
T
IO
N S
Y S
T E
M
IN
T
E R
N A
L E
L E
C T
R
IF
IE
D
H A
R D
W A
R E
C O
N N
E C
T
IO
N
L O
C A
L P
U S
H B
U T
T O
N D
O O
R H
A R
D W
A R
E O
V E
R R
ID
E
M O
T
IO
N D
E T
E C
T O
R
E L
E C
T R
O N
IC
L
O C
K
IN
G H
A R
D W
A R
E
B Y
O T
H E
R S
M A
G L
O C
K
L A
T C
H S
T A
T U
S D
E T
E C
T
IO
N
L O
C A
L A
L A
R M
H O
R N
M O
N
IT
O R
L A
T C
H B
O L
T
M O
N
IT
O R
D O
O R
P O
S
IT
IO
N
S W
IT
C
H S
P D
T
M O
N
IT
O R
D O
O R
P O
S
IT
IO
N
S W
IT
C
H D
P D
T
M O
N
IT
O R
D O
O R
P O
S
IT
IO
N
S W
IT
C
H F
O R
O V
E R
H E
A D
D O
O R
D E
L A
Y E
D E
G R
E S
S
L O
C A
L
V
A C
P O
W E
R S
U P
P L
Y
S C
H E
D U
L E
B A
S E
D L
O C
K
IN
G
V
IS
U A
L S
T R
O B
E
1164A CR1 ● ● ●
2C11
1220A
S15
2C13
1225A
1230 1282
A
2C17
1264A
1236 1238 1240
S13402E5
402E5A
1250A
1250B
1250C 1250D
1280C
1280A
1280D
2C19
1280B
402M5
D
D
D
5D
4D
4D
D
4D
4D
6D
6D
D
4D4D
D
4D
D
D
6D
6D 6D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D 1V
4D 4D 4D
4D4D4D6D
4D
3D
D
3D
2D
2D
D
2D
D
4D
D
D
4D
D
2D
1D-WAP
1D-GWAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-GWAP
1D-WAP
1D-WAP
1D-GWAP
1D-GWAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-CAM
D
D
B402-TN300
EXISTING TR-402-1-1
B402-TN300
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :
B
IM
/2
V
A T o m a h
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-7
.B
.E
T
R
.r v t
/7
/2
:4
:0
P M
B402-TD101
FIRST FLOOR DEMOLITION -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES, TOMAH, WI
TOMAH, WI
676-700
B402
02/11/2022 PDN JFK
16477
225 W WASHINGTON STREET
SUITE 2700 CHICAGO, IL 60606
312.294.0501 FAX: 312.294.0003
www.imegcorp.com # 21003227.00
N O R
HT
1/8" = 1'-0"
FIRST FLOOR DEMOLITION - TELECOMMUNICATIONS
TECHNOLOGY SHEET NOTES:
1. REFER TO TN000 TECHNOLOGY COVERSHEET
FOR TECHNOLOGY SYMBOL LIST.
2. ALL INFORMATION OUTLETS ON THIS SHEET
SERVED FROM EXISTING TR-402-1-1.
3. ALL EXISTING INFORMATION OUTLETS,
CONDUITS AND BACKBOXES TO REMAIN.
EXISTING CABLING TO BE REMOVED FROM
END TO END AND REPLACED WITH NEW DATA
CABLES. REFER TO B402-TN101 FOR MORE
INFORMATION.
KEYNOTES:
1. EXISTING BACKBONE AND HORIZONTAL
COPPER AND FIBER TO BE COMPLETELY
REMOVED FROM END TO END AFTER
COMPLETION OF ALL NEW CABLING.
2241A
2201 2200
2C21
2C23
2235 2237
S15 2232 2234 2238
2240A
2240C
B
2254 2258
2258A
S13 2286
2C29
2289A
2292A
2257A22572255
2275 2274
2269A 2274A
2263 2264
2C28
2C272
2217A 2218
2218A
2C22
2205A 2204A
2282A
4D 4D
4D 4D
3D
V
V
3D
2V 2V
2D
V
D
4D
D
D
4D
D
V
1V 1V
1V1V
D
D
D
V
V
D
D
D
V
V
3D
V
V
D
V
V
D
D
D
4D4D
V
V
D
D
V
2V
2D
2D
2V 2V
D
D
V
3D
V
V
D
V 3D2V
2V
4D4D
V
3D
D 4D
D
D 4 D
4D 3D
3D 3D 2V2D 2 V
V
V
D
4D
1D-WAP
1D-WAP
1D-CAM
1D-WAP
1D-WAP
1D-WAP2D 2D
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-CAM
4D
B402-TN301
B402-TN301
EXISTING TR-402-2-1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :
B
IM
/2
V
A T o m a h
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-7
.B
.E
T
R
.r v t
/7
/2
:4
:0
P M
B402-TD102
SECOND FLOOR DEMOLITION -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES, TOMAH, WI
TOMAH, WI
676-700
B402
02/11/2022 PDN JFK
16477
225 W WASHINGTON STREET
SUITE 2700 CHICAGO, IL 60606
312.294.0501 FAX: 312.294.0003
www.imegcorp.com # 21003227.00
N O R
HT
1/8" = 1'-0"
SECOND FLOOR DEMOLITION - TELECOMMUNICATIONS
TECHNOLOGY SHEET NOTES:
1. REFER TO TN000 TECHNOLOGY COVERSHEET
FOR TECHNOLOGY SYMBOL LIST.
2. ALL INFORMATION OUTLETS ON THIS SHEET
SERVED FROM EXISTING TR-402-2-1.
3. ALL EXISTING INFORMATION OUTLETS,
CONDUITS AND BACKBOXES TO REMAIN.
EXISTING CABLING TO BE REMOVED FROM
END TO END AND REPLACED WITH NEW DATA
CABLES. REFER TO B402-TN102 FOR MORE
INFORMATION.
KEYNOTES:
1. EXISTING BACKBONE AND HORIZONTAL
COPPER AND FIBER TO BE COMPLETELY
REMOVED FROM END TO END AFTER
COMPLETION OF ALL NEW CABLING.
LOUNGE
VISITOR
CONFERENCE
STAFF
LOBBY
HALLWAY
CART
CRASH
ELEVATOR #1
ELEVATOR #2
3201 3200
32023203
32043205
3205A 3204A
32083209
2C31
3229 3231
2C33
3217A
2C32
32223221
S15 3228 3230
3240C
3240B
3240A
3218A
2C37
3252 3254
3254A
S13
3253 3255 3255A
3263A 3264A
32583259
2C38
3276A
32803281
3277A
2C39
3239A
STORAGE
SPD
D
V
V
D
D
D
D
D
V
V
V
V
D
V
2V 3D
3D 2V
D
D
D
D
D
D
D
V
V
V
V
D
4D 4D
D
D
D 2
D
3D
D
2V
2D
D 2
D
D
V
D
D
D
D
D
V
D
D
D
D
1V
V
V
D
V
D
4D
4D
D
D
D
D
V
V
V
V
D
V 2 V
V
3D 2V
2V 2 V3D
D
D
D
3D
D
D
V
2V
V
V
1D-CAM
1D-WAP
1D-GWAP
1D-GWAP
1D-GWAP
1D-GWAP
1D-WAP
3D
1D-GWAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-CAM
4D
B402-TN302
EXISTING TR-402-3-1
B402-TN302
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :
B
IM
/2
V
A T o m a h
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-7
.B
.E
T
R
.r v t
/7
/2
:4
:0
P M
B402-TD103
THIRD FLOOR DEMOLITION -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES, TOMAH, WI
TOMAH, WI
676-700
B402
02/11/2022 PDN JFK
16477
225 W WASHINGTON STREET
SUITE 2700 CHICAGO, IL 60606
312.294.0501 FAX: 312.294.0003
www.imegcorp.com # 21003227.00
N O R
HT
1/8" = 1'-0"
THIRD FLOOR DEMOLITION - TELECOMMUNICATIONS
TECHNOLOGY SHEET NOTES:
1. REFER TO TN000 TECHNOLOGY COVERSHEET
FOR TECHNOLOGY SYMBOL LIST.
2. ALL INFORMATION OUTLETS ON THIS SHEET
SERVED FROM EXISTING TR-402-3-1.
3. ALL EXISTING INFORMATION OUTLETS,
CONDUITS AND BACKBOXES TO REMAIN.
EXISTING CABLING TO BE REMOVED FROM
END TO END AND REPLACED WITH NEW DATA
CABLES. REFER TO B402-TN103 FOR MORE
INFORMATION.
KEYNOTES:
1. EXISTING BACKBONE AND HORIZONTAL
COPPER AND FIBER TO BE COMPLETELY
REMOVED FROM END TO END AFTER
COMPLETION OF ALL NEW CABLING.
UP
TO/FROM BUILDING 32
(1) 4" FOR A LEG
(1) 4" FOR COPPER
(2) 4" CONDUIT - (20) 25-PAIR CAT 5E
JUNCTION BOX LOCATION OF TR-402-1-1
ON FIRST FLOOR
(1) 4" CONDUIT - (3) A LEG FIBERS
(1) 4" CONDUIT - SPARE
PULLBOX (TYP.)
1 (TYP.)
JUNCTION BOX
(1) 4" CONDUIT - (10) 25-PAIR CAT 5E
(1) 4" CONDUIT - SPARE
(1) 4" C - (10) CAT 5E 25-PAIRS COPPER CABLES
(1) 4" C FOR COPPER
SC-HH-1
(2) 4" SLEEVES
(1) 4" CONDUIT - (3) B LEG FIBERS
(1) 4" CONDUIT - SPARE
JUNCTION BOX
(1) 4" CONDUIT - (3) B LEG FIBERS
(1) 4" CONDUIT - SPARE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :
B
IM
/2
V
A T o m a h
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-7
.B
.E
T
R
.r v t
/7
/2
:4
:0
P M
B402-TN100
BASEMENT FLOOR -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES, TOMAH, WI
TOMAH, WI
676-700
B402
02/11/2022 PDN JFK
16477
225 W WASHINGTON STREET
SUITE 2700 CHICAGO, IL 60606
312.294.0501 FAX: 312.294.0003
www.imegcorp.com # 21003227.00
N O R
HT
1/8" = 1'-0"
BASEMENT FLOOR - TELECOMMUNICATIONS
TECHNOLOGY SHEET NOTES:
1. REFER TO TN000 TECHNOLOGY COVERSHEET
FOR TECHNOLOGY GENERAL NOTES,
TECHNOLOGY INSTALLATION NOTES AND
SYMBOL LIST.
2. REFER TO TN600 FOR GENERAL TECHNOLOGY
EQUIPMENT SCHEDULE.
3. CONTRACTOR TO COORDINATE PULL BOX
LOCATIONS AS REQUIRED.
4. CONTRACTOR TO FIELD VERIFY CONDUIT
RISER ROUTE WITH OWNER PRIOR TO
INSTALLATION.
TO/FROM
BUILDING 403
KEYNOTES:
1. CONTRACTOR TO PROVIDED PULL BOX SIZED
PER CODE REQUIREMENT.
2. PROVIDE SC-HH-1 5' FROM EXTERIOR WALL.
REFER TO 1/TN401 EXTERIOR HAND HOLE
DETAIL FOR ADDITIONAL INFORMATION.
3. (2) 4" CONDUITS PROVIDED BY OTHERS.
COORDINATE WITH CIVIL DRAWINGS.
4. REFER TO 3/TN401 EXTERIOR WALL
PENETRATION DETAIL FOR ADDITIONAL
INFORMATION.
CONFERENCE
CONTROL
ELEVATOR
LOBBY
CONFERENCE
PRMS
STORAGE
GENERAL
HALLWAY
ELEVATOR #1
ELEVATOR #2
2C11
1220A
S15
2C13
1225A
1230 1282
A
2C17
1264A
1236 1238 1240
S13402E5
402E5A
1250A
1250B
1250C 1250D
1280C
1280A
1280D
2C19
1280B
402M5
1D-GWAP
1D-GWAP
1D-GWAP
1D-GWAP
D
D
D
5D
4D
4D
D
4D
4D
6D
6D
D
4D4D
D
4D
D
D
6D
6D 6D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D 1D
4D 4D 4D
4D4D4D6D
4D
3D
D
3D
2D
2D
D
2D
D
4D
D
D
4D
D
2D
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-CAM
CSS
W
P
D
D
1D-CAM
1225A
TOILET /
SHOWER
TELECOM
B402-TN300
B402-TN300
TR-402-1-1
1225F
EXISTING TR-402-1-1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :
B
IM
/2
V
A T o m a h
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-7
.B
.E
T
R
.r v t
/7
/2
:4
:0
P M
B402-TN101
FIRST FLOOR -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES, TOMAH, WI
TOMAH, WI
676-700
B402
02/11/2022 PDN JFK
16477
225 W WASHINGTON STREET
SUITE 2700 CHICAGO, IL 60606
312.294.0501 FAX: 312.294.0003
www.imegcorp.com # 21003227.00
N O R
HT
1/8" = 1'-0"
FIRST FLOOR - TELECOMMUNICATIONS
TECHNOLOGY SHEET NOTES:
1. REFER TO TN000 TECHNOLOGY COVERSHEET
FOR TECHNOLOGY GENERAL NOTES,
TECHNOLOGY INSTALLATION NOTES AND
SYMBOL LIST.
2. ALL INFORMATION OUTLETS ON THIS SHEET
SHALL BE SERVED FROM TR-402-1-1.
3. REFER TO TN600 FOR GENERAL TECHNOLOGY
EQUIPMENT SCHEDULE.
4. CONTRACTOR TO INCLUDE AN ALLOWANCE
FOR 10 ADDITIONAL 2-PORTS CAT 6A
INFORMATION OUTLETS IN THEIR PROPOSAL
FOR THIS SHEET. FUTURE INFORMATION
OUTLET LOCATIONS WILL BE DETERMINED BY
THE VA AT A LATER DATE.
5. CONTRACTOR TO FIELD VERIFY CONDUIT
RISER ROUTE WITH OWNER PRIOR TO
INSTALLATION.
6. ALL INFORMATION OUTLETS ON THIS SHEET
TO BE CABLED ON A SCHEDULED BASIS WITH
OWNER WHILE OCCUPIED WITH STAFF AND
PATIENTS. COORDINATE DEMO AND CABLE
REPLACEMENT WITH OWNER. REFER TO
SHEET B402-TD101 FOR MORE INFORMATION.
7. CONTRACTOR TO PROVIDE NEW J-HOOK
ROUTES FOR ALL NEW CABLING. J-HOOK SIZE
AND QUANTITY TO BE PER MANUFACTURER
RECOMMENDATIONS.
VISITOR
OFFICE
PHYSICIANS
LOBBY
CART
CRASH
HALLWAY
ELEVATOR #1
ELEVATOR #2
2241A
2201 2200
2C21
2C23
2235 2237
S15 2232 2234 2238
2240A
2240C
B
2254 2258
2258A
S13 2286
2C29
2289A
2292A
2257A22572255
2275 2274
2269A 2274A
2263 2264
2C28
2C272
2217A 2218
2218A
2C22
2205A 2204A
2282A
OFFICE
4D 4D
4D 4D
3D
D
D
3D
2D 2D
2D
D
D
4D
D
D
4D
D
D
1D 1D
1D1D
D
D
D
D
D
D2 D
D
D
D
3D
D
D
D
D
D
D
D
D
4D4D
D
D
D
D
D
2D
2D
2D
2D 2D
D
D
D
3D
D
D
D
3D2D
2D
4D4D
D
3D
D 4D
D
D 4 D
4D 3D
3D 5D2D 2 D
D
D
D
4D
1D-WAP
1D-WAP
1D-CAM
1D-WAP
1D-WAP
1D-WAP2D 2D
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-CAM
CSS
W
P
4D
1D-CAM
TELECOM
TELECOM
B402-TN301
B402-TN301
TR-402-2-1
1225T
EXISTING TR-402-2-1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :
B
IM
/2
V
A T o m a h
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-7
.B
.E
T
R
.r v t
/7
/2
:4
:0
P M
B402-TN102
SECOND FLOOR -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES, TOMAH, WI
TOMAH, WI
676-700
B402
02/11/2022 PDN JFK
16477
225 W WASHINGTON STREET
SUITE 2700 CHICAGO, IL 60606
312.294.0501 FAX: 312.294.0003
www.imegcorp.com # 21003227.00
N O R
HT
1/8" = 1'-0"
SECOND FLOOR - TELECOMMUNICATIONS
TECHNOLOGY SHEET NOTES:
1. REFER TO TN000 TECHNOLOGY COVERSHEET
FOR TECHNOLOGY GENERAL NOTES,
TECHNOLOGY INSTALLATION NOTES AND
SYMBOL LIST.
2. ALL INFORMATION OUTLETS ON THIS SHEET
SHALL BE SERVED FROM TR-402-2-1.
3. REFER TO TN600 FOR GENERAL TECHNOLOGY
EQUIPMENT SCHEDULE.
4. CONTRACTOR TO INCLUDE AN ALLOWANCE
FOR 10 ADDITIONAL 2-PORTS CAT 6A
INFORMATION OUTLETS IN THEIR PROPOSAL
FOR THIS SHEET. FUTURE INFORMATION
OUTLET LOCATIONS WILL BE DETERMINED BY
THE VA AT A LATER DATE.
5. CONTRACTOR TO FIELD VERIFY CONDUIT
RISER ROUTE WITH OWNER PRIOR TO
INSTALLATION.
6. ALL INFORMATION OUTLETS ON THIS SHEET
TO BE CABLED ON A SCHEDULED BASIS WITH
OWNER WHILE OCCUPIED WITH STAFF AND
PATIENTS. COORDINATE DEMO AND CABLE
REPLACEMENT WITH OWNER. REFER TO
SHEET B402-TD102 FOR MORE INFORMATION.
7. CONTRACTOR TO PROVIDE NEW J-HOOK
ROUTES FOR ALL NEW CABLING. J-HOOK SIZE
AND QUANTITY TO BE PER MANUFACTURER
RECOMMENDATIONS.
VISITOR
CONFERENCE
STAFF
LOBBY
HALLWAY
CART
CRASH
ELEVATOR #1
ELEVATOR #2
3201 3200
32023203
32043205
3205A 3204A
32083209
2C31
3229 3231
2C33
3217A
2C32
32223221
S15 3228 3230
3240C
3240B
3240A
3218A
2C37
3252 3254
3254A
S13
3253 3255 3255A
3263A 3264A
32583259
2C38
3276A
32803281
3277A
2C39
3239A
STORAGE
SPD
1D-GWAP
1D-GWAP
1D-GWAP
1D-GWAP
1D-GWAP
D
D
D
D
D
D
D
D
D
D
D
D
D
2D 3D
3D 2D
D
D
D
D
D
D
D
D
D
D
D
D
4D 4D
D
D
D 2
D
3D
D
2D
2D
D 2
D
D 1
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
4D
4D
D
D
D
D
D
D
D
D
D
D
D
3D 2D
2D 2 D3D
D
D
D
3D
D
D
D
2D
D
D
1D-CAM
1D-WAP
1D-WAP
3D
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
W
P
CSS
1D-CAM
1D-WAP
4D
1D-CAM
3231A
TELECOM
EXAM
TELECOM
B402-TN302
B402-TN302
TR-402-3-1
1225JJ
EXISTING TR-402-3-1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :
B
IM
/2
V
A T o m a h
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-7
.B
.E
T
R
.r v t
/7
/2
:4
:0
P M
B402-TN103
THIRD FLOOR -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES, TOMAH, WI
TOMAH, WI
676-700
B402
02/11/2022 PDN JFK
16477
225 W WASHINGTON STREET
SUITE 2700 CHICAGO, IL 60606
312.294.0501 FAX: 312.294.0003
www.imegcorp.com # 21003227.00
N O R
HT
1/8" = 1'-0"
THIRD FLOOR - TELECOMMUNICATIONS
TECHNOLOGY SHEET NOTES:
1. REFER TO TN000 TECHNOLOGY COVERSHEET
FOR TECHNOLOGY GENERAL NOTES,
TECHNOLOGY INSTALLATION NOTES AND
SYMBOL LIST.
2. ALL INFORMATION OUTLETS ON THIS SHEET
SHALL BE SERVED FROM TR-402-3-1.
3. REFER TO TN600 FOR GENERAL TECHNOLOGY
EQUIPMENT SCHEDULE.
4. CONTRACTOR TO INCLUDE AN ALLOWANCE
FOR 10 ADDITIONAL 2-PORTS CAT 6A
INFORMATION OUTLETS IN THEIR PROPOSAL
FOR THIS SHEET. FUTURE INFORMATION
OUTLET LOCATIONS WILL BE DETERMINED BY
THE VA AT A LATER DATE.
5. CONTRACTOR TO FIELD VERIFY CONDUIT
RISER ROUTE WITH OWNER PRIOR TO
INSTALLATION.
6. ALL INFORMATION OUTLETS ON THIS SHEET
TO BE CABLED ON A SCHEDULED BASIS WITH
OWNER WHILE OCCUPIED WITH STAFF AND
PATIENTS. COORDINATE DEMO AND CABLE
REPLACEMENT WITH OWNER. REFER TO
SHEET B402-TD103 FOR MORE INFORMATION.
7. CONTRACTOR TO PROVIDE NEW J-HOOK
ROUTES FOR ALL NEW CABLING. J-HOOK SIZE
AND QUANTITY TO BE PER MANUFACTURER
RECOMMENDATIONS.
SC-FDC-1
SC-MPP-1
P
P T
Z
C C
T V
SC-MPP-2
OWNER
PROVIDED
NETWORK
EQUIPMENT
SC-MPP-2
SC-FDC-1 SC-MPP-1
SC-FDC-1
SC-BET
B -T
N
EXISTING WIRE MANAGER (TYP.)
EXISTING EQUIPMENT RACK (TYP.)
SC-FDC-1
SC-MPP-1
NOTES:
1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES OF MATERIALS SHOWN. THIS RISER IS SHOWN FOR CLARIFICATION OF CONNECTION(S), LOCATIONS AND CABLE TYPE. ALL INFORMATION OUTLETS ARE TYPICAL OF THE OUTLETS IN THE AREA SHOWN. REFER TO FLOOR PLANS FOR MORE SPECIFIC ROUTING INFORMATION. REFER TO SPECIFICATIONS FOR
ADDITIONAL REQUIREMENTS.
2. REFER TO TN600 FOR TECHNOLOGY EQUIPMENT SCHEDULE.
KEYNOTES:
1. CONTRACTOR TO PROVIDE (2) FIBER OPTIC PATCH CORDS FOR CONNECTIVITY TO OWNER EQUIPMENT.
2. CONTRACTOR TO PROVIDE (6) CAT 6A PATCH CORDS FOR CONNECTIVITY TO OWNER EQUIPMENT.
EXISTING TR-402-1-1
24 STRAND SM FIBER FROM
TR-402-1-1
TO OWNER PROVIDED
EQUIPMENT
24 CAT 6A CABLES FROM
TR-402-1-1
TO OWNER PROVIDED
EQUIPMENT
SC-GND-1
(TYP.)
SC-TTB (TYP.)
SC-VWM-1
B -T
N
SC-ER-1
(TYP.)
CM-1
01-01 4
PW-CPW-1
SC-CT-2
(TYP.)
(2) 4" C FROM
BASEMENT
(2) 4" C FROM
BASEMENT
(2) 4" C FROM
BASEMENT
18"x6"
"x
"x
"1
"x
18"x6"
SC-BET
(TYPICAL OF 5)
SC-VWM-1 SC-ER-1
(TYP.)(TYP.)
SC-FDC-1
SC-BLK-1
SC-MPP-2
SC-MPP-2
SC-MPP-2
SC-MPP-2
SC-MPP-2
SC-MPP-2
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-HWM-1
SC-HWM-2
SC-HWM-2
SC-HWM-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-FDC-1
SC-BLK-1
SC-MPP-2
SC-MPP-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-HWM-2
SC-HWM-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
NETWORK SWITCH
NETWORK SWITCH
NETWORK SWITCH
NETWORK SWITCH
NETWORK SWITCH
UPS UPS
PDU
24 STRAND SM FIBER FROM
BUILDING 32 (LEG A)
(10) CAT 5E 25-PAIRS COPPER
CABLES FROM BUILDING 32
NOTES:
1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES OF MATERIALS SHOWN.
THIS RISER IS SHOWN FOR CLARIFICATION OF CONNECTION(S), LOCATIONS AND CABLE TYPE. ALL INFORMATION OUTLETS ARE TYPICAL OF THE OUTLETS IN THE AREA SHOWN. REFER TO FLOOR PLANS FOR MORE SPECIFIC ROUTING INFORMATION. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
2. REFER TO TN600 FOR TECHNOLOGY EQUIPMENT SCHEDULE.
KEYNOTES:
1. #D INDICATES VOICE/DATA FACEPLATE CONFIGURATION. REFER TO INFORMATION OUTLET SCHEDULE ON
TN600 FOR ADDITIONAL INFORMATION. REFER TO TECHNOLOGY FLOOR PLANS AND TECHNOLOGY
EQUIPMENT SCHEDULE FOR ADDITIONAL INFORMATION.
2. FIBER OPTIC PATCH CORDS. REFER TO SPECIFICATIONS.
3. 24 GAUGE, CAT 6A UTP CABLE. REFER TO SPECIFICATIONS.
4. RJ-45 TO RJ-45 CATEGORY 6A UTP PATCH CORDS.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .