Atch 14 - Telecommunications 3 of 4.pdf
PDF 16 MB Posted
- Attached to
- Y1AZ--EHRM Infrastructure Upgrades Construction - Tomah Federal contract opportunity
- Solicitation number
- 36C77622B0031
About this file
This federal contract opportunity solicitation involves infrastructure upgrades and renovations at the Tomah VA Medical Center in Wisconsin. The solicitation seeks contractors to perform electrical, HVAC, communication, physical security, and fiber infrastructure upgrades across multiple buildings on campus. Additional requirements include modifying impacted roads, walks, grading and drainage, hazardous material abatement, and data center WAN updates. The solicitation was issued by the Department of Veterans Affairs Technology Acquisition Center located in Austin, Texas.
View the file
Other files for this federal contract opportunity
Show all 42
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ELEV.
10500
10508
1050110599
10510
10512
10505
10511
10513
10515
10517
10518
10519
10520
10522
10521
10524
10526
10523
10525
10527
10528
01B 10B
11B
15B
18B
20B
19B
24B
23B
28B
10597
10596
10589
10591
10592
10588
10590
10585
10586
10577
10581
10583
UP
UP
1D-CAM
1D-CAM
1D-CAM
D
-C A
M
1D-CAM
1D-WAP
D 1
D
3D
1D
3D
1D
3D
1D
3D
1D
3D
1D
1D-CAM1D-CAM
1D-WAP
D
D
3D
1D
3D
1D
3D
1D
3D
1D
3D
1D
3D
1D
3D
1D
3D
1D
1D-CAM
1D-GWAP
1D-WAP
1D-GWAP
1D-WAP
1D-GWAP
1D-CAM
1D-WAP
D
-C A
M
D
3D
1D
1D-WAP
1D-CAM
V
1D -C
A M
1D-WAP
D
D
D
D
V
1D-CAM
1D-GWAP
1D-WAP
1V
D
D
D
1D-CAM
1D-CAM
D
-C A
M
1D-WAP
D
-C A
M
1D-CAM
1D
V
1D-WAP
1D-WAP
1D-WAP
D
4D
1D-CAM
1D-WAP
1D-CAM
1D-WAP
1D-CAM
1D-CAM
1D-CAM
1D-GWAP
1D-CAM
1D-WAP
1D-CAM
1D-WAP
1D-CAM
1D-CAM
P T
Z
C C
T V
TR-405-1-1
FROM BUILDING 404 TO
ROOM 10592
EXISTING (2) 6" CONDUITS
IN TUNNEL
(1) 6" CONDUIT - (3) B LEG FIBERS
(1) 6" CONDUIT - (6) 25-PAIR CAT 5E
EXISTING 1X4 DUCTBANK
FROM 10592
EXISTING (1) 4" CONDUIT - (3) A LEG FIBERS
EXISTING (3) 4" CONDUITS - SPARE
B405-TN300
B405-TN300
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :
B
IM
/2
V
A T o m a h
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-7
.B
.E
T
R
.r v t
/8
/2
:0
:4
P
M
B405-TN101
FIRST FLOOR -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES, TOMAH, WI
TOMAH, WI
676-21-700
B405
02/11/2022 PDN JFK
16477
225 W WASHINGTON STREET
SUITE 2700 CHICAGO, IL 60606
312.294.0501 FAX: 312.294.0003
www.imegcorp.com # 21003227.00
N O R
HT
1/8" = 1'-0"
FIRST FLOOR - TELECOMMUNICATIONS
TECHNOLOGY SHEET NOTES:
1. REFER TO TN000 TECHNOLOGY COVERSHEET
FOR TECHNOLOGY GENERAL NOTES,
TECHNOLOGY INSTALLATION NOTES AND
SYMBOL LIST.
2. ALL INFORMATION OUTLETS ON THIS SHEET
SHALL BE SERVED FROM EXISTING TR-405-1-1.
3. REFER TO TN600 FOR GENERAL TECHNOLOGY
EQUIPMENT SCHEDULE.
4. INFORMATION OUTLETS ARE SHOWN FOR
REFERENCE ONLY. RE-CABLING THIS FLOOR IS
NOT REQUIRED.
5. CONTRACTOR TO FIELD VERIFY CONDUIT
RISER ROUTE WITH OWNER PRIOR TO
INSTALLATION.
0 8' 16'4'
Revisions: Date:
20506
ELEV.
Lounge
20510
20508
20501
20500
20504
20584
84B
20583
20586
20585
83B
86B
20588
20587
20581
81B
20579
10B 20512
20511
11B
20513
20515
15B
20517
20519
20521
19B
20518
20516
20520
18B
20522
20524
22B 20523
20525
23B
20527
20599
20598
20595
20596
20593
20591
20589
87B
20577
20535
20537
37B20539
20541
20543 20545
77B 43B
45B
41B
39B
20544 20546
20503
20505
20547
93B
D
1D
1D
1D
1D
1D
1D
1D
D
3D
3D
3D
3D
3D
3D
3D
D
4D 4D 4D 4D 4D 4D
4D 4D 4D 4D
4D 4D
4D
3D
D
1D
1D
1D
1D
1D
1D
1D
1D
4D 4D 4D
4D
3D
3D
3D
3D
3D
3D
3D
3D
D
D
D
D
D
D
D
D
D
D
1D
1D
1D
1D
3D
3D
3D
4D 4D
1D
1D
1D
1D
3D
3D
3D
3D
1D
D
D
D
D
1D-CAM
1D-CAM
1D-WAP
1D-GWAP
1D-WAP 1D-WAP
1D-GWAP
1D-CAM
1D-WAP
1D-CAM
1D-GWAP
1D-CAM 1D-WAP
1D-WAP
1D-GWAP
1D-WAP
1D-WAP
1D-GWAP
1D-CAM
1D-WAP
1D-CAM
1D-WAP
1D-WAP
1D-CAM
1D-WAP
1D-GWAP
1D-WAP
1D-CAM
1D-WAP
1D-CAM
1D-WAP
1D-CAM
1D-CAM
1D-WAP
1D-WAP
1D-GWAP
1D-GWAP
1D-WAP
1D-WAP
1D-WAP
1D-CAM
1D-WAP
4D
1D-CAM
P T
Z
C C
T V
TR-405-2-1
B405-TN301
B405-TN301
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :
B
IM
/2
V
A T o m a h
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-7
.B
.E
T
R
.r v t
/8
/2
:0
:5
P
M
B405-TN102
SECOND FLOOR -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES, TOMAH, WI
TOMAH, WI
676-21-700
B405
02/11/2022 PDN JFK
16477
225 W WASHINGTON STREET
SUITE 2700 CHICAGO, IL 60606
312.294.0501 FAX: 312.294.0003
www.imegcorp.com # 21003227.00
N O R
HT
1/8" = 1'-0"
SECOND FLOOR - TELECOMMUNICATIONS
TECHNOLOGY SHEET NOTES:
1. REFER TO TN000 TECHNOLOGY COVERSHEET
FOR TECHNOLOGY GENERAL NOTES,
TECHNOLOGY INSTALLATION NOTES AND
SYMBOL LIST.
2. ALL INFORMATION OUTLETS ON THIS SHEET
SHALL BE SERVED FROM EXISTING TR-405-2-1.
3. REFER TO TN600 FOR GENERAL TECHNOLOGY
EQUIPMENT SCHEDULE.
4. INFORMATION OUTLETS ARE SHOWN FOR
REFERENCE ONLY. RE-CABLING THIS FLOOR IS
NOT REQUIRED.
5. CONTRACTOR TO FIELD VERIFY CONDUIT
RISER ROUTE WITH OWNER PRIOR TO
INSTALLATION.
CORR.
3C01
CORR.
3C06
CORR.
3C03
CORR.
3C03
ELEV.
EL01
CORR.
3C05
CORR.
3C07
CORR.
3C04
CORR.
3C08
CORR.
3C09
CORR.
3C10
STAIR 22
3S22
STAIR 23
3S23
30599 30501 30503
30505
30512
30511
30513
30504 30506
30516
30508
30515
30517
30519
30521
30523
30525
30527
30518
30520
30522
30524
3053730539
30541
3054330545
30547 30535
30577
30579
30581
30546
30584
30583
30586
30585
30587
30588
30589
30591
30593
30596
30595
30598 30500
12B
11B
15B
18B
19B
22B
23B
37B
39B
41B
43B
45B
81B
84B
83B
86B
87B
93B
DN
DN
4D
4D
1D
1D
1D
1D
4D
4D
4D
4D
D
4D 4D 4D 4D
4D 4D
1D
4D
4D
4D
4D
4D
4D
4D
4D
4D
4D
4D 4D 4D
1D
1D
1D
1D
1D
1D
1D
1D 4D
1D
4D
1D
1D
1D
4D
4D
4D
D
D
D
D
D
4D 1D
4D
4D
4D
1D
1D
4D
D
1D-WAP
D
-C A
M
1D-WAP 1D-CAM
1D-CAM
1D-WAP
1D-CAM
1D-CAM
1D-GWAP
1D-WAP
1D-WAP
1D-GWAP
1D-WAP
1D-WAP
1D-CAM
1D-CAM
1D-WAP
1D-CAM
1D-WAP
1D-WAP 1D-GWAP
1D-WAP
1D-WAP
1D-CAM
1D-WAP
1D-CAM1D-CAM
1D-GWAP
1D-CAM
1D-WAP
1D-WAP
1D-GWAP
1D-WAP
1D-WAP
1D-CAM
1D-GWAP
1D-CAM
1D-WAP
1D-WAP
1D-CAM
1D-CAM
1D-GWAP
1D-CAM
1D-CAM
1D-WAP
1D-WAP
4D
1D-CAM
P T
Z
C C
T V
TR-405-3-1
B405-TN302
B405-TN302
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :
B
IM
/2
V
A T o m a h
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-7
.B
.E
T
R
.r v t
/8
/2
:0
:5
P
M
B405-TN103
THIRD FLOOR -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES, TOMAH, WI
TOMAH, WI
676-21-700
B405
02/11/2022 PDN JFK
16477
225 W WASHINGTON STREET
SUITE 2700 CHICAGO, IL 60606
312.294.0501 FAX: 312.294.0003
www.imegcorp.com # 21003227.00
N O R
HT
1/8" = 1'-0"
THIRD FLOOR - TELECOMMUNICATIONS
TECHNOLOGY SHEET NOTES:
1. REFER TO TN000 TECHNOLOGY COVERSHEET
FOR TECHNOLOGY GENERAL NOTES,
TECHNOLOGY INSTALLATION NOTES AND
SYMBOL LIST.
2. ALL INFORMATION OUTLETS ON THIS SHEET
SHALL BE SERVED FROM EXISTING TR-405-3-1.
3. REFER TO TN600 FOR GENERAL TECHNOLOGY
EQUIPMENT SCHEDULE.
4. INFORMATION OUTLETS ARE SHOWN FOR
REFERENCE ONLY. RE-CABLING THIS FLOOR IS
NOT REQUIRED.
5. CONTRACTOR TO FIELD VERIFY CONDUIT
RISER ROUTE WITH OWNER PRIOR TO
INSTALLATION.
P T
Z
C C
T V
1D-CAM
EXISTING
PATCH PANEL
OWNER
PROVIDED
NETWORK
EQUIPMENT
SC-MPP-2
SC-FDC-1
SC-BET
EXISTING WALL RACK
EXISTING ACCESS CONTROL
CABINET
EXISTING WIRE MANAGER
(TYP.)
EXISTING EQUIPMENT RACK
(TYP.)
B -T
N
EXISTING TV
AMPLIFIER
EXISTING LADDER RACK
(TYP.)
EXISTING VERTICAL LADDER RACK
EXISTING CONDUITS
(4) 4" C
(2) 6" C
EXST. WIRE MANAGER
EXST. WIRE MANAGER
EXST. WIRE MANAGER
EXST. WIRE MANAGER
EXST. WIRE MANAGER
EXST. WIRE MANAGER
EXST. SWITCH
EXST. WIRE MANAGER
EXST. PATCH PANEL
EXST. PATCH PANEL
EXST. PATCH PANEL
EXST. PATCH PANEL
EXST. FIBER PANEL
EXST. FIBER PANEL
EXST. WIRE MANAGER
EXST. EQUIPMENT
EXISTING WIRE MANAGER (TYP.)
EXISTING EQUIPMENT RACK (TYP.)
EXISTING WALL RACK
EXISTING ACCESS CONTROL
CABINET
B -T
N
SC-VWM-1
SC-ER-1
EXISTING TV
AMPLIFIER
(TYP.)
(TYP.)
SC-TTB (TYP.)
SC-GND-1 1
2CM-1
01-01
EXISTING VERTICAL LADDER RACK
EXISTING CONDUITS
(4) 4" C
(2) 6" C
SC-CT-2
(TYP.)
18"x6"
"x
"x
"x
18"x6"
SC-BET
(TYPICAL OF 3)
EXST. WIRE MANAGER
EXST. WIRE MANAGER
EXST. WIRE MANAGER
EXST. WIRE MANAGER
EXST. WIRE MANAGER
EXST. WIRE MANAGER
EXST. SWITCH
EXST. WIRE MANAGER
EXST. PATCH PANEL
EXST. PATCH PANEL
EXST. PATCH PANEL
EXST. PATCH PANEL
EXST. FIBER PANEL
EXST. FIBER PANEL
EXST. WIRE MANAGER
EXST. EQUIPMENT
SC-VWM-1 SC-ER-1
(TYP.)(TYP.)
SC-FDC-1
SC-MPP-2
PDU
UPS UPS
3 3
24 STRAND SM FIBER FROM
BUILDING 32 (LEG A)
(6) CAT 5E 25-PAIRS COPPER
CABLES FROM BUILDING 32
NOTES:
1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES OF MATERIALS SHOWN. THIS RISER IS SHOWN FOR CLARIFICATION OF CONNECTION(S), LOCATIONS AND CABLE TYPE. ALL INFORMATION OUTLETS ARE TYPICAL OF THE OUTLETS IN THE AREA SHOWN. REFER TO FLOOR PLANS FOR MORE SPECIFIC ROUTING INFORMATION. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
2. REFER TO TN600 FOR TECHNOLOGY EQUIPMENT SCHEDULE.
KEYNOTES:
1. FIBER OPTIC PATCH CORDS. REFER TO SPECIFICATIONS FOR PATCH CORD REQUIREMENTS.
2. RJ-45 TO RJ-45 CATEGORY 6A UTP PATCH CORDS. REFER TO SPECIFICATIONS FOR PATCH CORD
REQUIREMENTS.
3. CONTRACTOR SHALL TERMINATE 1 PAIR PER PORT, USING PINS 4 AND 5.
4. LIGHTNING PROTECTION. REFER TO 5/B405-TN300 FOR LOCATION.
5. (2) CAT 5E 25-PAIR CABLES FROM LIGHTNING PROTECTION.
6. 24 GAUGE, CAT 6A UTP CABLE. REFER TO SPECIFICATIONS.
7. PROVIDE CAT 6A CABLE FOR CAMERA. TERMINATE CAT 6A CABLE WITH RJ-45 PLUG.
24 STRAND SM FIBER FROM
BUILDING 32 (LEG B)
TR-405-1-1
PTZ
CCTV ##-##
CM-1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :
B
IM
/2
V
A T o m a h
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-7
.B
.E
T
R
.r v t
/8
/2
:0
:5
P
M
B405-TN300
TELECOMMUNICATIONS ROOM
ENLARGEMENTS
EHRM INFRASTRUCTURE
UPGRADES, TOMAH, WI
TOMAH, WI
676-21-700
B405
02/11/2022 PDN JFK
16477
225 W WASHINGTON STREET
SUITE 2700 CHICAGO, IL 60606
312.294.0501 FAX: 312.294.0003
www.imegcorp.com # 21003227.00
N O R
HT
1/4" = 1'-0"
DATA ROOM ENLARGEMENT - EXISTING TR-405-1-1
N O R
HT
1/4" = 1'-0"
LADDER RACK LAYOUT - EXISTING TR-405-1-1
1" = 1'-0"
DATA RACK ELEVATION - EXISTING TR-405-1-1
N O R
HT
1/4" = 1'-0"
DATA ROOM ENLARGEMENT - TR-405-1-1
N O R
HT
1/4" = 1'-0"
LADDER RACK LAYOUT - TR-405-1-1
5 1" = 1'-0"
DATA RACK ELEVATION - TR-405-1-1
NO SCALE
CONNECTIVITY RISER DIAGRAM - TR-405-1-1
NOTES:
1. REFER TO 2/B405-TN300 FOR LADDER RACK LAYOUT - EXISTING TR-405-1-1.
2. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.
KEYNOTES:
1. REMOVE EXISTING PATCH PANELS FROM 2-POST RACK WITHOUT REMOVING HORIZONTAL CABLES. CONTRACTOR TO REMOVE EXISTING 2-POST RACKS. RACK MOUNTED DEVICES TO BE REMOVED AND PROTECTED FOR RE-INSTALLATION.
EXISTING EQUIPMENT RACKS TO REMAIN UNTIL ALL RACK MOUNTED DEVICES RELOCATED TO NEW SC-ER-1.
NOTES:
1. REFER TO 5/B405-TN300 FOR LADDER RACK LAYOUT - TR-405-1-1.
2. REFER TO 7/B405-TN300 FOR CONNECTIVITY RISER DIAGRAM - TR-405-1-1.
3. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.
KEYNOTES:
1. REFER TO 1/TN400 BONDING BUS BAR DETAIL FOR ADDITIONAL INFORMATION.
2. REFER TO AE211 FOR PLYWOOD INFORMATION.
3. CONTRACTOR TO COORDINATE FINAL RACK LOCATION WITH OWNER PRIOR TO INSTALLATION.
4. CONTRACTOR TO COORDINATE FINAL LOCATION AND FIELD OF VIEW WITH OWNER PRIOR TO
INSTALLATION.
NOTES:
1. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.
KEYNOTES:
1. REMOVE EXISTING PATCH PANELS FROM 2-POST RACKS WITHOUT REMOVING HORIZONTAL CABLES. REMOVE
2- POST RACKS AND REPLACE THEM WITH SC-ER-1.
NOTES:
1. REFER TO 7/B405-TN300 FOR CONNECTIVITY RISER DIAGRAM - TR-405-1-1.
2. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.
KEYNOTES:
1. REINSTALL EXISTING PATCH PANELS ON SC-ER-1.
2. CONTRACTOR TO TEST AND CERTIFY ALL HORIZONTAL CABLING ON THIS PATCH
PANEL AFTER INSTALLATION ON SC-ER-1.
3. UPS AND PDU’S PROVIDED AND INSTALLED BY THE E.C. REFER TO ELECTRICAL
DRAWINGS FOR MORE INFORMATION.
NOTES:
1. INSTALL BASKET TRAY AT 7'-6" AFF.
2. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.
3. REFER TO 2/B405-TN400 TECHNOLOGY CONDUIT RISER DIAGRAM.
4. REFER TO TN503 CONDUIT AND CABLE PATHWAY DIAGRAMS FOR ADDITIONAL
INFORMATION.
KEYNOTES:
1. CONTRACTOR TO COORDINATE FINAL LOCATION FOR LIGHTNING PROTECTION
ENCLOSURE WITH OWNER PRIOR TO INSTALLATION.
0 4' 8'2' 0 4' 8'2'
0 4' 8'2'
0 4' 8'2'
STAMP
Z
C C
T V
1D-CAM
EXISTING
PATCH PANEL
OWNER
PROVIDED
NETWORK
EQUIPMENT
SC-MPP-2
SC-FDC-1
SC-BET
EXISTING ACCESS CONTROL
CABINET
EXISTING WALL RACK
EXISTING CABINET
EXISTING WIRE MANAGER
(TYP.)
EXISTING EQUIPMENT RACK
(TYP.)
EXISTING GROUND BAR
B -T
N
EXISTING TV AMPLIFIER
EXISTING LADDER RACK
(TYP.)
EXISTING WIRE MANAGER
(TYP.)
EXISTING EQUIPMENT RACK
(TYP.)
NETWORK SWITCH
NETWORK SWITCH
EXISTING PAGING
EQUIPMENT
EXISTING NURSE CALL
EQUIPMENT
EXISTING NURSE CALL
EQUIPMENT
EXISTING NURSE CALL
EQUIPMENT
EXISTING EQUIPMENT
EXISTING EQUIPMENT
EXST. WIRE MANAGER
EXST. WIRE MANAGER
EXST. WIRE MANAGER
EXST. WIRE MANAGER
EXST. WIRE MANAGER
EXST. WIRE MANAGER
EXST. PATCH PANEL
EXST. PATCH PANEL
EXST. PATCH PANEL
EXST. PATCH PANEL
EXST. PATCH PANEL
EXST. FIBER PANEL
EXISTING PAGING
EQUIPMENT
B -T
N
SC-VWM-1
(TYP.)
EXISTING ACCESS CONTROL
CABINET
EXISTING WALL RACK
EXISTING CABINET
EXISTING GROUND BAR
SC-ER-1
EXISTING TV AMPLIFIER
SC-TTB
(TYP.)
(TYP.)
CM-1
02-01
SC-CT-2
(TYP.)
18"x6"
"x
"x
"x
18"x6"
SC-VWM-1
(TYP.)
SC-ER-1
(TYP.)
NETWORK SWITCH
NETWORK SWITCH
EXISTING PAGING
EQUIPMENT
EXISTING EQUIPMENT
EXISTING EQUIPMENT
EXST. WIRE MANAGER
EXST. WIRE MANAGER
EXST. WIRE MANAGER
EXST. WIRE MANAGER
EXST. WIRE MANAGER
EXST. WIRE MANAGER
EXST. PATCH PANEL
EXST. PATCH PANEL
EXST. PATCH PANEL
EXST. PATCH PANEL
EXST. PATCH PANEL
EXST. FIBER PANEL
SC-FDC-1
SC-MPP-2
EXISTING PAGING
EQUIPMENT
EXISTING NURSE CALL
EQUIPMENT
EXISTING NURSE CALL
EQUIPMENT
EXISTING NURSE CALL
EQUIPMENT
PDU
UPS UPS
5 5
24 STRAND SM FIBER FROM
BUILDING 32 (LEG A)
(6) CAT 5E 25-PAIRS COPPER
CABLES FROM BUILDING 32
NOTES:
1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES OF MATERIALS SHOWN. THIS RISER IS SHOWN FOR CLARIFICATION OF CONNECTION(S), LOCATIONS AND CABLE TYPE.
ALL INFORMATION OUTLETS ARE TYPICAL OF THE OUTLETS IN THE AREA SHOWN. REFER TO FLOOR PLANS FOR MORE SPECIFIC ROUTING INFORMATION. REFER TO SPECIFICATIONS FOR ADDITIONAL
REQUIREMENTS.
2. REFER TO TN600 FOR TECHNOLOGY EQUIPMENT SCHEDULE.
KEYNOTES:
1. FIBER OPTIC PATCH CORDS. REFER TO SPECIFICATIONS FOR PATCH CORD REQUIREMENTS.
2. RJ-45 TO RJ-45 CATEGORY 6A UTP PATCH CORDS. REFER TO SPECIFICATIONS FOR PATCH CORD
REQUIREMENTS.
3. CONTRACTOR SHALL TERMINATE 1 PAIR PER PORT, USING PINS 4 AND 5.
4. LIGHTNING PROTECTION. REFER TO 5/B405-TN300 FOR LOCATION.
5. (2) CAT 5E 25-PAIR CABLES FROM LIGHTNING PROTECTION.
6. 24 GAUGE, CAT 6A UTP CABLE. REFER TO SPECIFICATIONS.
7. PROVIDE CAT 6A CABLE FOR CAMERA. TERMINATE CAT 6A CABLE WITH RJ-45 PLUG.
24 STRAND SM FIBER FROM
BUILDING 32 (LEG B)
TR-405-2-1
TR-405-1-1
PTZ
CCTV ##-##
CM-1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :
B
IM
/2
V
A T o m a h
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-7
.B
.E
T
R
.r v t
/8
/2
:0
:0
P
M
B405-TN301
TELECOMMUNICATIONS ROOM
ENLARGEMENTS
EHRM INFRASTRUCTURE
UPGRADES, TOMAH, WI
TOMAH, WI
676-21-700
B405
02/11/2022 PDN JFK
16477
225 W WASHINGTON STREET
SUITE 2700 CHICAGO, IL 60606
312.294.0501 FAX: 312.294.0003
www.imegcorp.com # 21003227.00
N O R
HT
1/4" = 1'-0"
DATA ROOM ENLARGEMENT - EXISTING TR-405-2-1
N O R
HT
1/4" = 1'-0"
LADDER RACK LAYOUT - EXISTING TR-405-2-1
1" = 1'-0"
DATA RACK ELEVATION - EXISTING TR-405-2-1
NOTES:
1. REFER TO 2/B405-TN301 FOR LADDER RACK LAYOUT - EXISTING TR-405-2-1.
2. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.
KEYNOTES:
1. REMOVE EXISTING PATCH PANELS FROM 2-POST RACK WITHOUT REMOVING HORIZONTAL CABLES. CONTRACTOR TO REMOVE EXISTING 2-POST RACKS. RACK MOUNTED DEVICES TO BE REMOVED AND PROTECTED FOR RE-INSTALLATION.
EXISTING EQUIPMENT RACKS TO REMAIN UNTIL ALL RACK MOUNTED DEVICES RELOCATED TO NEW SC-ER-1.
NOTES:
1. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.
KEYNOTES:
1. REMOVE EXISTING PATCH PANELS FROM 2-POST RACKS WITHOUT REMOVING HORIZONTAL CABLES. REMOVE
2- POST RACKS AND REPLACE THEM WITH SC-ER-1.
2. EXISTING PAGING EQUIPMENT TO BE REMOVED FROM 2-POST RACK FOR INSTALLATION INTO SC-ER-1 WITHOUT
REMOVING OR RE-CABLING EXISTING CABLES.
3. EXISTING NURSE CALL EQUIPMENT TO BE REMOVED FROM 2-POST RACK FOR INSTALLATION INTO SC-ER-1
WITHOUT REMOVING OR RE-CABLING EXISTING CABLES.
N O R
HT
1/4" = 1'-0"
DATA ROOM ENLARGEMENT - TR-405-2-1
N O R
HT
1/4" = 1'-0"
LADDER RACK LAYOUT - TR-405-2-1
1" = 1'-0"
DATA RACK ELEVATION - TR-405-2-1
NO SCALE
CONNECTIVITY RISER DIAGRAM - TR-405-2-1
NOTES:
1. REFER TO 5/B405-TN301 FOR LADDER RACK LAYOUT - TR-405-2-1.
2. REFER TO 7/B405-TN301 FOR CONNECTIVITY RISER DIAGRAM - TR-405-2-1.
3. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.
KEYNOTES:
1. REFER TO AE211 FOR PLYWOOD INFORMATION.
2. CONTRACTOR TO COORDINATE FINAL RACK LOCATION WITH OWNER PRIOR TO INSTALLATION.
3. CONTRACTOR TO COORDINATE FINAL LOCATION AND FIELD OF VIEW WITH OWNER PRIOR TO
INSTALLATION.
NOTES:
1. REFER TO 7/B405-TN301 FOR CONNECTIVITY RISER DIAGRAM - TR-405-2-1.
2. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.
KEYNOTES:
1. REINSTALL EXISTING PATCH PANELS ON SC-ER-1.
2. CONTRACTOR TO TEST AND CERTIFY ALL HORIZONTAL CABLING ON THIS PATCH
PANEL AFTER INSTALLATION ON SC-ER-1.
3. REINSTALL PAGING SYSTEM IN SC-ER-1. TEST AND CERTIFY SYSTEM FOR COMPLETE
OPERATION.
4. REINSTALL NURSE CALL SYSTEM IN SC-ER-1. TEST AND CERTIFY SYSTEM FOR
COMPLETE OPERATION.
5. UPS AND PDU’S PROVIDED AND INSTALLED BY THE E.C. REFER TO ELECTRICAL
DRAWINGS FOR MORE INFORMATION.
NOTES:
1. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.
2. INSTALL BASKET TRAY AT 7'-6" AFF.
3. REFER TO 2/B405-TN400 TECHNOLOGY CONDUIT RISER DIAGRAM.
4. REFER TO TN503 CONDUIT AND CABLE PATHWAY DIAGRAMS FOR ADDITIONAL
INFORMATION.
0 4' 8'2' 0 4' 8'2'
0 4' 8'2'
0 4' 8'2'
Z
C C
T V
1D-CAM
EXISTING
PATCH PANEL
OWNER
PROVIDED
NETWORK
EQUIPMENT
SC-MPP-2
SC-FDC-1
SC-BET
B -T
N
3EXISTING WALL RACK
EXISTING WIRE MANAGER
(TYP.)
EXISTING EQUIPMENT RACK
(TYP.)
EXISTING GROUND BAR
EXISTING LADDER RACK
(TYP.)
EXISTING WIRE MANAGER
(TYP.)
EXISTING EQUIPMENT RACK
(TYP.)
EXISTING NURSE CALL
EQUIPMENT
EXISTING NURSE CALL
EQUIPMENT
EXISTING NURSE CALL
EQUIPMENT
EXISTING FIBER
PANEL
EXISTING FIBER
PANEL
EXISTING WIRE
MANAGER
EXISTING WIRE
MANAGER
EXISTING WIRE
MANAGER
EXISTING WIRE
MANAGER
EXISTING WIRE
MANAGER
EXISTING WIRE
MANAGER
EXISTING WIRE
MANAGER
EXISTING PATCH
PANEL
EXISTING PATCH
PANEL
EXISTING PATCH
PANEL
EXISTING PATCH
PANEL
EXISTING PATCH
PANEL
EXISTING WIRE
MANAGER
EXISTING EQUIPMENT
EXISTING EQUIPMENT
B -T
N
SC-VWM-1
(TYP.)
SC-ER-1
(TYP.)
EXISTING WALL RACK
EXISTING GROUND BAR
SC-TTB
(TYP.)
CM-1
03-01
SC-CT-2
(TYP.)
18"x6"
"x
"x
"x
18"x6"
EXISTING NURSE CALL
EQUIPMENT
EXISTING NURSE CALL
EQUIPMENT
EXISTING NURSE CALL
EQUIPMENT
EXISTING FIBER
PANEL
EXISTING FIBER
PANEL
EXISTING WIRE
MANAGER
EXISTING WIRE
MANAGER
EXISTING WIRE
MANAGER
EXISTING WIRE
MANAGER
EXISTING WIRE
MANAGER
EXISTING WIRE
MANAGER
EXISTING WIRE
MANAGER
EXISTING PATCH
PANEL
EXISTING PATCH
PANEL
EXISTING PATCH
PANEL
EXISTING PATCH
PANEL
EXISTING PATCH
PANEL
EXISTING WIRE
MANAGER
EXISTING EQUIPMENT
EXISTING EQUIPMENT
SC-FDC-1
SC-MPP-2
SC-VWM-1 SC-ER-1
(TYP.) (TYP.)
1 2
1 2
1 2
1 2
1 2
PDU
UPS UPS
4 4
24 STRAND SM FIBER FROM
BUILDING 32 (LEG A)
(6) CAT 5E 25-PAIRS COPPER
CABLES FROM BUILDING 32
NOTES:
1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES OF MATERIALS SHOWN. THIS RISER IS SHOWN FOR CLARIFICATION OF CONNECTION(S), LOCATIONS AND CABLE TYPE. ALL INFORMATION OUTLETS ARE TYPICAL OF THE OUTLETS IN THE AREA SHOWN. REFER TO FLOOR PLANS FOR MORE SPECIFIC ROUTING INFORMATION. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
2. REFER TO TN600 FOR TECHNOLOGY EQUIPMENT SCHEDULE.
KEYNOTES:
1. FIBER OPTIC PATCH CORDS. REFER TO SPECIFICATIONS.
2. RJ-45 TO RJ-45 CATEGORY 6A UTP PATCH CORDS. REFER TO SPECIFICATIONS FOR PATCH CORD
REQUIREMENTS.
3. CONTRACTOR SHALL TERMINATE 1 PAIR PER PORT, USING PINS 4 AND 5.
4. LIGHTNING PROTECTION. REFER TO 5/B405-TN300 FOR LOCATION.
5. (2) CAT 5E 25-PAIR CABLES FROM LIGHTNING PROTECTION.
6. 24 GAUGE, CAT 6A UTP CABLE. REFER TO SPECIFICATIONS.
7. PROVIDE CAT 6A CABLE FOR CAMERA. TERMINATE CAT 6A CABLE WITH RJ-45 PLUG.
24 STRAND SM FIBER FROM
BUILDING 32 (LEG B)
EXISTING TR-405-3-1
TR-405-1-1
PTZ
CCTV ##-##
CM-1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :
B
IM
/2
V
A T o m a h
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-7
.B
.E
T
R
.r v t
/8
/2
:0
:0
P
M
B405-TN302
TELECOMMUNICATIONS ROOM
ENLARGEMENTS
EHRM INFRASTRUCTURE
UPGRADES, TOMAH, WI
TOMAH, WI
676-21-700
B405
02/11/2022 PDN JFK
16477
225 W WASHINGTON STREET
SUITE 2700 CHICAGO, IL 60606
312.294.0501 FAX: 312.294.0003
www.imegcorp.com # 21003227.00
N O R
HT
1/4" = 1'-0"
DATA ROOM ENLARGEMENT - EXISTING TR-405-3-1
N O R
HT
1/4" = 1'-0"
LADDER RACK LAYOUT - EXISTING TR-405-3-1
1" = 1'-0"
DATA RACK ELEVATION - EXISTING TR-405-3-1
N O R
HT
1/4" = 1'-0"
DATA ROOM ENLARGEMENT - TR-405-3-1
N O R
HT
1/4" = 1'-0"
LADDER RACK LAYOUT - TR-405-3-1
1" = 1'-0"
DATA RACK ELEVATION - TR-405-3-1
NO SCALE
CONNECTIVITY RISER DIAGRAM - TR-405-3-1
NOTES:
1. REFER TO 2/B405-TN302 FOR LADDER RACK LAYOUT - EXISTING TR-405-3-1.
2. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.
KEYNOTES:
1. REMOVE EXISTING PATCH PANELS FROM 2-POST RACK WITHOUT REMOVING HORIZONTAL CABLES. CONTRACTOR TO REMOVE EXISTING 2-POST RACKS. RACK MOUNTED DEVICES TO BE REMOVED AND PROTECTED FOR RE-INSTALLATION.
EXISTING EQUIPMENT RACKS TO REMAIN UNTIL ALL RACK MOUNTED DEVICES RELOCATED TO NEW SC-ER-1.
NOTES:
1. REFER TO 5/B405-TN302 FOR LADDER RACK LAYOUT - TR-405-3-1.
2. REFER TO 7/B405-TN302 FOR CONNECTIVITY RISER DIAGRAM - TR-405-3-1.
3. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.
KEYNOTES:
1. REFER TO AE211 FOR PLYWOOD INFORMATION.
2. CONTRACTOR TO COORDINATE FINAL RACK LOCATION WITH OWNER PRIOR TO INSTALLATION.
3. CONTRACTOR TO COORDINATE FINAL LOCATION AND FIELD OF VIEW WITH OWNER PRIOR TO
INSTALLATION.
NOTES:
1. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.
KEYNOTES:
1. REMOVE EXISTING PATCH PANELS FROM 2-POST RACKS WITHOUT REMOVING HORIZONTAL CABLES. REMOVE
2- POST RACKS AND REPLACE THEM WITH SC-ER-1.
2. EXISTING NURSE CALL EQUIPMENT TO BE REMOVED FROM 2-POST RACK FOR INSTALLATION INTO SC-ER-1
WITHOUT REMOVING OR RE-CABLING EXISTING CABLES.
NOTES:
1. REFER TO 7/B405-TN302 FOR CONNECTIVITY RISER DIAGRAM - TR-405-3-1.
2. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.
KEYNOTES:
1. REINSTALL EXISTING PATCH PANELS ON SC-ER-1.
2. CONTRACTOR TO TEST AND CERTIFY ALL HORIZONTAL CABLING ON THIS PATCH
PANEL AFTER INSTALLATION ON SC-ER-1.
3. REINSTALL NURSE CALL SYSTEM IN SC-ER-1. TEST AND CERTIFY SYSTEM FOR
COMPLETE OPERATION.
4. UPS AND PDU’S PROVIDED AND INSTALLED BY THE E.C. REFER TO ELECTRICAL
DRAWINGS FOR MORE INFORMATION.
NOTES:
1. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.
2. INSTALL BASKET TRAY AT 7'-6" AFF.
3. REFER TO 2/B405-TN400 TECHNOLOGY CONDUIT RISER DIAGRAM.
4. REFER TO TN503 CONDUIT AND CABLE PATHWAY DIAGRAMS FOR ADDITIONAL
INFORMATION.
0 4' 8'2' 0 4' 8'2'
0 4' 8'2'
0 4' 8'2'
SC-GND-1
EXISTING
GROUND BAR
EXISTING
GROUND BAR
ELECTRICAL ENTRANCE
INTERSYSTEM BONDING
TERMINATION
GROUNDING ELECTRODE
CONDUCTOR BY OTHERS
ELECTRICAL GROUNDING
ELECTRODE SYSTEM
EXISTING TELECOMMUNICATIONS BONDING
BACKBONE (TBB) (TYP)
FIRST
FLOOR
SECOND
FLOOR
THIRD
FLOOR
EXISTING TR-405-1-1
EXISTING TR-405-2-1
EXISTING TR-405-3-1
NOTES:
1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES OF
MATERIALS. THIS RISER IS SHOWN FOR CLARIFICATION OF CONNECTION LOCATIONS AND
CONDUCTOR TYPE. ALL CONNECTIONS AND SYSTEM DEVICES SHOWN ARE TYPICAL AND NOT
REPRESENTATIVE OF ACTUAL PROJECT QUANTITIES. REFER TO FLOOR PLANS AND ENLARGED
FLOOR PLANS FOR ACTUAL QUANTITIES AND LOCATIONS OF DEVICES AND MORE SPECIFIC ROUTING
INFORMATION. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
2. ALL CONDUCTORS IN THE TECHNOLOGY BONDING SYSTEM SHALL BE MINIMUM SIZE OF 3/0 AWG
PLENUM RATED COPPER (GREEN OR MARKED WITH A DISTINCTIVE GREEN COLOR) UNLESS
CONDUCTOR LENGTH IS LESS THAN 66 FEET. REFER TO BONDING CONDUCTOR SIZING SCHEDULE
FOR SIZING CRITERIA FOR CONDUCTORS LESS THAN 66 FEET IN LENGTH. REFER TO
SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
3. ALL BONDING CONDUCTORS AND BONDING JUMPERS SHALL BE CONNECTED BY COMPRESSION
LUGS, EXOTHERMIC WELDING, OR IRREVERSIBLE COMPRESSION CONNECTORS. SOLDER IS NOT AN
ACCEPTABLE MEANS OF CONNECTION. SHEET METAL SCREWS SHALL NOT BE USED TO CONNECT
COMMUNICATIONS BONDING CONDUCTORS TO EQUIPMENT. WHERE NECESSARY, REMOVE PAINT
AND/OR USE PAINT-PIERCING WASHERS TO PROVIDE PROPER ELECTRICAL BOND AT ALL
CONNECTIONS.
4. REFER TO 2/TN400 FOR TYPICAL TELECOM ROOM BONDING FLOW DIAGRAM.
5. REFER TO TELECOM ROOM REFERENCES SCHEDULE ON DRAWING TN000 FOR
TELECOMMUNICATIONS ROOM NUMBER AND LOCATION INFORMATION.
KEYNOTES:
1. BONDING CONDUCTOR FOR TELECOMMUNICATIONS (BCT).
FIRST
FLOOR
SECOND
FLOOR
THIRD
FLOOR
TR-405-1-1
TR-405-2-1
TR-405-3-1
EXISTING 4" CONDUITS
EXISTING (4) 4" CONDUITS IN DUCT BANK
TO B404
EXISTING (2) 6" CONDUITS
IN TUNNEL TO B404
(2) 4" C
(2) 4" C
(2) 4" C
(2) 4" C
NOTES:
1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES OF
MATERIALS SHOWN. THIS RISER IS SHOWN FOR CLARIFICATION OF CONNECTION(S), LOCATIONS AND CABLE TYPE. ALL INFORMATION OUTLETS ARE TYPICAL OF THE OUTLETS IN THE AREA SHOWN.
REFER TO FLOOR PLANS FOR MORE SPECIFIC ROUTING INFORMATION. REFER TO SPECIFICATIONS
FOR ADDITIONAL REQUIREMENTS.
2. REFER TO TN600 FOR TECHNOLOGY EQUIPMENT SCHEDULE.
3. REFER TO TN503 CONDUIT AND CABLE PATHWAY DIAGRAMS FOR ADDITIONAL INFORMATION.
SC-BET
EXISTING 6" CONDUITS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :
B
IM
/2
V
A T o m a h
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-7
.B
.E
T
R
.r v t
/8
/2
:0
:0
P
M
B405-TN400
TELECOMMUNICATIONS DETAILS EHRM INFRASTRUCTURE
UPGRADES, TOMAH, WI
TOMAH, WI
676-21-700
B405
02/11/2022 PDN JFK
16477
225 W WASHINGTON STREET
SUITE 2700 CHICAGO, IL 60606
312.294.0501 FAX: 312.294.0003
www.imegcorp.com # 21003227.00
NO SCALE
TECHNOLOGY BONDING RISER DIAGRAM
NO SCALE
TECHNOLOGY CONDUIT RISER DIAGRAM
Revisions: Date:
INDIVIDUAL CAMERA REQUIREMENTS SCHEDULE
CAMERA #
CAMERA
TYPE FIELD OF VIEW DESCRIPTION
DETAIL
REFERENCE NOTES
01-01 CM-1 GENERAL VIEW OF
TELECOMMUNICATION ROOM
6/TN400
02-01 CM-1 GENERAL VIEW OF
TELECOMMUNICATION ROOM
6/TN400
03-01 CM-1 GENERAL VIEW OF
TELECOMMUNICATION ROOM
6/TN400
6C13
1615A
1615C
6C17
1646B
16481 A
1647 1649 1658 1675
1640A 1640 1640B 1646 S22 1672
1615B
S24
406E8A
C
1647A
1653 1654
406E8
1617A
1631A
2D 4D
1D-WAP
D
3D
3D3D
1D-WAP
D
1D-WAP
1V2D
1D-WAP 6
D
D 6
D
1V 2V
V
D
4D
D
4D
D
4D
D
1D-CAM
1D-WAP
D 6
D
3D
V
1D-CAM
1D-CAM
3D 1V
1D-WAP
D
1D-WAP
D
V
D
D
4V
3D3D1D-WAP
3D 3D 4V
4V
D
1D1V
D
D
1D-WAP
1D-GWAP
4D
D
3D 1D-WAP
D
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-CAM
D
4D
EXISTING TR-406-1-1
B406-TN300
B406-TN300
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :
B
IM
/2
V
A T o m a h
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-7
.B
.E
T
R
.r v t
/8
/2
:0
:3
P
M
B406-TD101
FIRST FLOOR DEMOLITION -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES, TOMAH, WI
TOMAH, WI
676-700
B406
02/11/2022 PDN JFK
16477
225 W WASHINGTON STREET
SUITE 2700 CHICAGO, IL 60606
312.294.0501 FAX: 312.294.0003
www.imegcorp.com # 21003227.00
TECHNOLOGY SHEET NOTES:
1. REFER TO TN000 TECHNOLOGY COVERSHEET
FOR TECHNOLOGY SYMBOL LIST.
2. ALL INFORMATION OUTLETS ON THIS SHEET
SERVED FROM EXISTING TR-406-1-1
3. ALL EXISTING INFORMATION OUTLETS,
CONDUITS AND BACKBOXES TO REMAIN.
EXISTING CABLING TO BE REMOVED FROM
END TO END AND REPLACED WITH NEW DATA
CABLES. REFER TO B406-TN101 FOR MORE
INFORMATION.
N O R
HT
1/8" = 1'-0"
FIRST FLOOR DEMOLITION - TELECOMMUNICATIONS
KEYNOTES:
1. EXISTING BACKBONE AND HORIZONTAL
COPPER AND FIBER TO BE COMPLETELY
REMOVED FROM END TO END AFTER
COMPLETION OF ALL NEW CABLING.
2. EXISTING ANALOG HORIZONTAL AND RISER
CABLING TO BE COMPLETELY REMOVED
AFTER ALL ACTIVE PORTS HAVE BEEN
ABANDONED. COORDINATE REMOVAL WITH
OWNER.
DN. 20-R.
2607 2608
S24
6C21
6C23
2629A
2633A
6C25
2634A
2603A
2604A
6C22
26202621
2632 2640 2646 2648 S22 2674
2631 2633 2645 2649
6C28
2659A
2658A
6C29
6C27
2644A
V
2D 3D
1V
D
D
V
D
D
V
V
1D-WAP
1D-GWAP
1D-WAP
3D 2D
V
1V
D
D
D
V
D
V
1V2D3D
D
D
1D-WAP
1V2D3D
1V 2D
D
1D-WAP
D
2D1V
1V 2D
D 1 V
D
2D1V 2D 1V
D
D
2D 1V
1V2D
D
D
2D 1V
2D
D
D
D
1D-WAP
V
D
D
2D
D
4D
D
D
1D-CAM
1D-WAP
1D-WAP
3D3D
D
V
D
D
1D-WAP
D
D
1V2D
D
1V2D
1D-WAP
3D
V
V
V
V
V
V
V
3D
V
V
D
2D1V
1D-WAP
D
D
1V 3D
D 3D
1V
2V
3D
1D-WAP
1V 1V
3D 2D 2D3D2D
D
V
V
3D 4V 2D
V
V
3D3D
D
D1D-WAP
D
5D
D
V
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
W
P
1D-CAM
1D-CAM
1D-CAM
D
EXISTING HILL ROM ROOM
EXISTING WALL FIELD
EXISTING TR-406-2-1
B406-TN301
B406-TN301
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :
B
IM
/2
V
A T o m a h
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-7
.B
.E
T
R
.r v t
/8
/2
:0
:3
P
M
B406-TD102
SECOND FLOOR DEMOLITION -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES, TOMAH, WI
TOMAH, WI
676-700
B406
02/11/2022 PDN JFK
16477
225 W WASHINGTON STREET
SUITE 2700 CHICAGO, IL 60606
312.294.0501 FAX: 312.294.0003
www.imegcorp.com # 21003227.00
N O R
HT
1/8" = 1'-0"
SECOND FLOOR DEMOLITION - TELECOMMUNICATIONS
TECHNOLOGY SHEET NOTES:
1. REFER TO TN000 TECHNOLOGY COVERSHEET
FOR TECHNOLOGY SYMBOL LIST.
2. ALL INFORMATION OUTLETS ON THIS SHEET
SERVED FROM EXISTING TR-406-2-1.
3. ALL EXISTING INFORMATION OUTLETS,
CONDUITS AND BACKBOXES TO REMAIN.
EXISTING CABLING TO BE REMOVED FROM
END TO END AND REPLACED WITH NEW DATA
CABLES. REFER TO B406-TN102 FOR MORE
INFORMATION.
KEYNOTES:
1. EXISTING BACKBONE AND HORIZONTAL
COPPER AND FIBER TO BE COMPLETELY
REMOVED FROM END TO END AFTER
COMPLETION OF ALL NEW CABLING.
2. EXISTING ANALOG HORIZONTAL AND RISER
CABLING TO BE COMPLETELY REMOVED
AFTER ALL ACTIVE PORTS HAVE BEEN
ABANDONED. COORDINATE REMOVAL WITH
OWNER.
3644A
DN. 20-R.
UP 13-R.
DN. 20-R.
6C31
3601 36023600
3604A
3603A
6C32 S24 3632 3636 3638
3640 3642
36503650B 3650A
3654 3656 3658 S22 3678
6C38
3663A
3668A
3683 3684
6C37
6C39
3631 3633 3635 3637
3635A
6C33
3623 3622
3650C
1D-CAM
D
2D3D
1D
D
D
1D
D
D
1D-GWAP
D
D
1D
D
D
1D
1D
5D
4D
1D
D
D
1D-GWAP
D
D
1D
1D
D
D
D
D
1D
1D-WAP
1D-WAP
D
D
1D
D
D
1D
1D-CAM
1V
D
D
D
D
6D
1D-WAP
D
D
1D-GWAP
4D
1D-CAM
D
1D-CAM
1D-WAP
D
3D 3D
1D-WAP
1D
4D
D
D
D
D
2D3D
D
1D
D
D
1D-GWAP
1D 2 D
D
1D
D
D
3D
1D-CAM
D
-C A
M
D
3D
3D2D
1D
1D
D
D
1D-GWAP
D
3D
D
D
1D
D
D
1D
D
D
1D
D
D
D
D
D
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
W P
WP
W
P
1D-CAM
1D-CAM
1D-CAM
4D
4D2D
EXISTING HILL ROM ROOM
EXISTING WALL FIELD
EXISTING TR-406-3-1
B406-TN302
B406-TN302
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :
B
IM
/2
V
A T o m a h
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-7
.B
.E
T
R
.r v t
/8
/2
:0
:3
P
M
B406-TD103
THIRD FLOOR DEMOLITION -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES, TOMAH, WI
TOMAH, WI
676-700
B406
02/11/2022 PDN JFK
16477
225 W WASHINGTON STREET
SUITE 2700 CHICAGO, IL 60606
312.294.0501 FAX: 312.294.0003
www.imegcorp.com # 21003227.00
N O R
HT
1/8" = 1'-0"
THIRD FLOOR DEMOLITION - TELECOMMUNICATIONS
TECHNOLOGY SHEET NOTES:
1. REFER TO TN000 TECHNOLOGY COVERSHEET
FOR TECHNOLOGY SYMBOL LIST.
2. ALL INFORMATION OUTLETS ON THIS SHEET
SERVED FROM EXISTING TR-406-3-1.
3. ALL EXISTING INFORMATION OUTLETS,
CONDUITS AND BACKBOXES TO REMAIN.
EXISTING CABLING TO BE REMOVED FROM
END TO END AND REPLACED WITH NEW DATA
CABLES. REFER TO B406-TN103 FOR MORE
INFORMATION.
KEYNOTES:
1. EXISTING BACKBONE AND HORIZONTAL
COPPER AND FIBER TO BE COMPLETELY
REMOVED FROM END TO END AFTER
COMPLETION OF ALL NEW CABLING.
2. EXISTING ANALOG HORIZONTAL AND RISER
CABLING TO BE COMPLETELY REMOVED
AFTER ALL ACTIVE PORTS HAVE BEEN
ABANDONED. COORDINATE REMOVAL WITH
OWNER.
BASEMENT
BA100
F.D.
F L A S H
T A N K
UP
(1) 4" FOR A LEG
FROM/TO BUILDING 401
(1) 4" FOR B LEG
(1) 4" FOR A LEG
(1) 4" FOR B LEG
(1) 4" FOR COPPER
FROM/TO BUILDING 455
JUNCTION BOX (TYP.)
4" C TO TR-406-1-1
PULLBOX (TYP.)
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :
B
IM
/2
V
A T o m a h
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-7
.B
.E
T
R
.r v t
/8
/2
:0
:3
P
M
B406-TN100
BASEMENT FLOOR PLAN -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES, TOMAH, WI
TOMAH, WI
676-700
B406
02/11/2022 PDN JFK
16477
225 W WASHINGTON STREET
SUITE 2700 CHICAGO, IL 60606
312.294.0501 FAX: 312.294.0003
www.imegcorp.com # 21003227.00
N O R
HT
1/8" = 1'-0"
BASEMENT FLOOR PLAN - TELECOMMUNICATIONS
TECHNOLOGY SHEET NOTES:
1. REFER TO TN000 TECHNOLOGY COVERSHEET
FOR TECHNOLOGY GENERAL NOTES,
TECHNOLOGY INSTALLATION NOTES AND
SYMBOL LIST.
2. REFER TO TN600 FOR GENERAL TECHNOLOGY
EQUIPMENT SCHEDULE.
3. CONTRACTOR TO COORDINATE PULL BOX
LOCATIONS AS REQUIRED.
4. CONTRACTOR TO FIELD VERIFY CONDUIT
RISER ROUTE WITH OWNER PRIOR TO
INSTALLATION.
KEYNOTES:
1. CONTRACTOR TO PROVIDE PULL BOX SIZED
PER CABLING AND CODE REQUIREMENTS.
6C13
1615A
1615C
6C17
1646B
16481 A
1647 1649 1658 1675
1640A 1640 1640B 1646 S22 1672
1615B
S24
406E8A
C
1647A
1653 1654
406E8
1617A
1631A
1D-GWAP
2D 4D
1D-WAP
D
3D
3D3D
1D-WAP
D
1D-WAP
1D2D
1D-WAP 6
D
D 6
D
1D 2D
D
D
4D
D
4D
D
4D
D
1D-CAM
1D-WAP
D 6
D
3D
D
1D-CAM
1D-CAM
3D 1D
1D-WAP
D
1D-WAP
D
D
D
D
4D
3D3D1D-WAP
3D 3D 4D
4D
D
2D
D
D
1D-WAP
4D
D
3D 1D-WAP
D
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
W
P
CSS
1D-CAM
D
4D
1D-CAM
B406-TN300
B406-TN300
TR-406-1-1
EXISTING TR-406-1-1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :
B
IM
/2
V
A T o m a h
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-7
.B
.E
T
R
.r v t
/8
/2
:0
:3
P
M
B406-TN101
FIRST FLOOR -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES, TOMAH, WI
TOMAH, WI
676-700
B406
02/11/2022 PDN JFK
16477
225 W WASHINGTON STREET
SUITE 2700 CHICAGO, IL 60606
312.294.0501 FAX: 312.294.0003
www.imegcorp.com # 21003227.00
N O R
HT
1/8" = 1'-0"
FIRST FLOOR - TELECOMMUNICATIONS
TECHNOLOGY SHEET NOTES:
1. REFER TO TN000 TECHNOLOGY COVERSHEET
FOR TECHNOLOGY GENERAL NOTES,
TECHNOLOGY INSTALLATION NOTES AND
SYMBOL LIST.
2. ALL INFORMATION OUTLETS ON THIS SHEET
SHALL BE SERVED FROM TR-406-1-1.
3. REFER TO TN600 FOR GENERAL TECHNOLOGY
EQUIPMENT SCHEDULE.
4. CONTRACTOR TO INCLUDE AN ALLOWANCE
FOR 10 ADDITIONAL 2-PORTS CAT 6A
INFORMATION OUTLETS IN THEIR PROPOSAL
FOR THIS SHEET. FUTURE INFORMATION
OUTLET LOCATIONS WILL BE DETERMINED BY
THE VA AT A LATER DATE.
5. CONTRACTOR TO FIELD VERIFY CONDUIT
RISER ROUTE WITH OWNER PRIOR TO
INSTALLATION.
6. ALL INFORMATION OUTLETS ON THIS SHEET
TO BE CABLED ON A SCHEDULED BASIS WITH
OWNER WHILE OCCUPIED WITH STAFF AND
PATIENTS. COORDINATE DEMO AND CABLE
REPLACEMENT WITH OWNER. REFER TO
SHEET B406-TD101 FOR MORE INFORMATION.
7. CONTRACTOR TO PROVIDE NEW J-HOOK
ROUTES FOR ALL NEW CABLING. J-HOOK SIZE
AND QUANTITY TO BE PER MANUFACTURER
RECOMMENDATIONS.
0 8' 16'4'
Revisions: Date:
KEYNOTES:
1. EXISTING ANALOG HORIZONTAL AND RISER
CABLING TO BE COMPLETELY REMOVED
AFTER ALL ACTIVE PORTS HAVE BEEN
ABANDONED. COORDINATE REMOVAL WITH
OWNER.
DN. 20-R.
2607 2608
S24
6C21
6C23
2629A
2633A
6C25
2634A
2603A
2604A
6C22
26202621
2632 2640 2646 2648 S22 2674
2631 2633 2645 2649
6C28
2659A
2658A
6C29
6C27
2644A
1D-GWAP
D
2D 3D
1D
D
D
D
D
D
D
D
1D-WAP
1D-WAP
3D 2D
D
1D
D
D
D
D
D
D
1D2D3D
D
D
1D-WAP
1D2D3D
1D 2D
D
1D-WAP
D
2D1D
1D 2D
D 1 D
D
2D1D 2D 1D
D
D
2D 1D
1D2D
D
D
2D 1D
2D
D
D
D
1D-WAP
D
D
D
2D
D
4D
D
D
1D-CAM
1D-WAP
1D-WAP
3D3D
D
D
D
D
1D-WAP
D
D
1D2D
D
1D2D
1D-WAP
3D
D
D
D
D
D
D
D
3D
D
D
D
2D1D
1D-WAP
D
D
1D 3D
D 3D
1D
2D
3D
1D-WAP
1D 1D
3D 2D 2D3D2D
D
3D 4D 2D
D
D
3D3D
D
D1D-WAP
D
5D
D
D
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
CSS
W
P
1D-CAM
D
1D-CAM
B406-TN301
B406-TN301
TR-406-2-1
EXISTING HILL ROM ROOM EXISTING WALL FIELD
EXISTING TR-406-2-1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :
B
IM
/2
V
A T o m a h
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-7
.B
.E
T
R
.r v t
/8
/2
:0
:3
P
M
B406-TN102
SECOND FLOOR -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES, TOMAH, WI
TOMAH, WI
676-700
B406
02/11/2022 PDN JFK
16477
225 W WASHINGTON STREET
SUITE 2700 CHICAGO, IL 60606
312.294.0501 FAX: 312.294.0003
www.imegcorp.com # 21003227.00
N O R
HT
1/8" = 1'-0"
SECOND FLOOR - TELECOMMUNICATIONS
TECHNOLOGY SHEET NOTES:
1. REFER TO TN000 TECHNOLOGY COVERSHEET
FOR TECHNOLOGY GENERAL NOTES,
TECHNOLOGY INSTALLATION NOTES AND
SYMBOL LIST.
2. ALL INFORMATION OUTLETS ON THIS SHEET
SHALL BE SERVED FROM TR-406-2-1.
3. REFER TO TN600 FOR GENERAL TECHNOLOGY
EQUIPMENT SCHEDULE.
4. CONTRACTOR TO INCLUDE AN ALLOWANCE
FOR 10 ADDITIONAL 2-PORTS CAT 6A
INFORMATION OUTLETS IN THEIR PROPOSAL
FOR THIS SHEET. FUTURE INFORMATION
OUTLET LOCATIONS WILL BE DETERMINED BY
THE VA AT A LATER DATE.
5. CONTRACTOR TO FIELD VERIFY CONDUIT
RISER ROUTE WITH OWNER PRIOR TO
INSTALLATION.
6. ALL INFORMATION OUTLETS ON THIS SHEET
TO BE CABLED ON A SCHEDULED BASIS WITH
OWNER WHILE OCCUPIED WITH STAFF AND
PATIENTS. COORDINATE DEMO AND CABLE
REPLACEMENT WITH OWNER. REFER TO
SHEET B406-TD102 FOR MORE INFORMATION.
7. CONTRACTOR TO PROVIDE NEW J-HOOK
ROUTES FOR ALL NEW CABLING. J-HOOK SIZE
AND QUANTITY TO BE PER MANUFACTURER
RECOMMENDATIONS.
0 8' 16'4'
Revisions: Date:
KEYNOTES:
1. EXISTING ANALOG HORIZONTAL AND RISER
CABLING TO BE COMPLETELY REMOVED
AFTER ALL ACTIVE PORTS HAVE BEEN
ABANDONED. COORDINATE REMOVAL WITH
3644A
DN. 20-R.
UP 13-R.
DN. 20-R.
6C31
3601 36023600
3604A
3603A
6C32 S24 3632 3636 3638
3640 3642
36503650B 3650A
3654 3656 3658 S22 3678
6C38
3663A
3668A
3683 3684
6C37
6C39
3631 3633 3635 3637
3635A
6C33
3623 3622
3650C
1D-GWAP
1D-GWAP
1D-GWAP
1D-GWAP
1D-GWAP
1D-CAM
D
2D3D
1D
D
D
1D
D
D
D
D
1D
D
D
1D
1D
5D
4D
1D
D
D
D
D
1D
1D
D
D
D
D
1D
1D-WAP
1D-WAP
D
D
1D
D
D
1D
1D-CAM
1D
D
D
D
D
6D
1D-WAP
D
D
4D
1D-CAM
D
1D-CAM
1D-WAP
D
3D 3D
1D-WAP
D
D
D
D
2D3D
D
1D
D
D
1D 2 D
D
1D
D
D
3D
1D-CAM
D
-C A
M
D
3D
3D2D
1D
1D
D
D
D
3D
D
D
1D
D
D
1D
D
D
1D
D
D
D
D
D
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
W
P
CSS
1D-CAM
4D2D
1D-CAM
B406-TN302
B406-TN302
TR-406-3-1
EXISTING HILL ROM ROOM
EXISTING WALL FIELD
EXISTING TR-406-3-1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :
B
IM
/2
V
A T o m a h
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-7
.B
.E
T
R
.r v t
/8
/2
:0
:3
P
M
B406-TN103
THIRD FLOOR -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES, TOMAH, WI
TOMAH, WI
676-700
B406
02/11/2022 PDN JFK
16477
225 W WASHINGTON STREET
SUITE 2700 CHICAGO, IL 60606
312.294.0501 FAX: 312.294.0003
www.imegcorp.com # 21003227.00
N O R
HT
1/8" = 1'-0"
THIRD FLOOR - TELECOMMUNICATIONS
TECHNOLOGY SHEET NOTES:
1. REFER TO TN000 TECHNOLOGY COVERSHEET
FOR TECHNOLOGY GENERAL NOTES,
TECHNOLOGY INSTALLATION NOTES AND
SYMBOL LIST.
2. ALL INFORMATION OUTLETS ON THIS SHEET
SHALL BE SERVED FROM TR-406-3-1.
3. REFER TO TN600 FOR GENERAL TECHNOLOGY
EQUIPMENT SCHEDULE.
4. CONTRACTOR TO INCLUDE AN ALLOWANCE
FOR 10 ADDITIONAL 2-PORTS CAT 6A
INFORMATION OUTLETS IN THEIR PROPOSAL
FOR THIS SHEET. FUTURE INFORMATION
OUTLET LOCATIONS WILL BE DETERMINED BY
THE VA AT A LATER DATE.
5. CONTRACTOR TO FIELD VERIFY CONDUIT
RISER ROUTE WITH OWNER PRIOR TO
INSTALLATION.
6. ALL INFORMATION OUTLETS ON THIS SHEET
TO BE CABLED ON A SCHEDULED BASIS WITH
OWNER WHILE OCCUPIED WITH STAFF AND
PATIENTS. COORDINATE DEMO AND CABLE
REPLACEMENT WITH OWNER. REFER TO
SHEET B406-TD103 FOR MORE INFORMATION.
7. CONTRACTOR TO PROVIDE NEW J-HOOK
ROUTES FOR ALL NEW CABLING. J-HOOK SIZE
AND QUANTITY TO BE PER MANUFACTURER
RECOMMENDATIONS.
0 8' 16'4'
Revisions: Date:
KEYNOTES:
1. EXISTING ANALOG HORIZONTAL AND RISER
CABLING TO BE COMPLETELY REMOVED
AFTER ALL ACTIVE PORTS HAVE BEEN
ABANDONED. COORDINATE REMOVAL WITH
PTZ
CCTV
SC-MPP-2
OWNER
PROVIDED
NETWORK
EQUIPMENT
SC-MPP-2
SC-FDC-1 SC-MPP-1
SC-BET
SC-FDC-1
SC-MPP-1
SC-FDC-1
SC-GND-1
SC-VWM-1
SC-ER-1 (TYP.)
B406-TN300
(TYP.)
CM-1
01-01
SC-CT-2
(TYP.)
PW-CPW-1
(2) 4" C FROM BASEMENT
(2) 4" C FROM BASEMENT
18"x6"
18"x6"
"x
"x
18"x6"
SC-BET
(TYPICAL OF 5)
SC-ER-1
(TYP.)
SC-FDC-1
SC-MPP-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-HWM-1
SC-HWM-2
SC-HWM-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-FDC-1
SC-BLK-1
SC-MPP-2
SC-MPP-2
SC-MPP-2
SC-MPP-2
SC-MPP-2
SC-MPP-2
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-HWM-1
SC-HWM-2
SC-HWM-2
SC-HWM-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
NETWORK SWITCH
NETWORK SWITCH
NETWORK SWITCH
NETWORK SWITCH
NETWORK SWITCH
(TYP.)
SC-VWM-1
PDU
UPS UPS
3 3
24 STRAND SM FIBER FROM
BUILDING 32 (LEG A)
(10) CAT 5E 25-PAIRS COPPER
CABLES FROM BUILDING 32
NOTES:
1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES OF MATERIALS SHOWN.
THIS RISER IS SHOWN FOR CLARIFICATION OF CONNECTION(S), LOCATIONS AND CABLE TYPE. ALL INFORMATION OUTLETS ARE TYPICAL OF THE OUTLETS IN THE AREA SHOWN. REFER TO FLOOR PLANS FOR MORE SPECIFIC ROUTING INFORMATION. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
2. REFER TO TN600 FOR TECHNOLOGY EQUIPMENT SCHEDULE.
KEYNOTES:
1. #D INDICATES VOICE/DATA FACEPLATE CONFIGURATION. REFER TO INFORMATION OUTLET SCHEDULE ON
TN600 FOR ADDITIONAL INFORMATION. REFER TO TECHNOLOGY FLOOR PLANS AND TECHNOLOGY
EQUIPMENT SCHEDULE FOR ADDITIONAL INFORMATION.
2. FIBER OPTIC PATCH CORDS. REFER TO SPECIFICATIONS.
3. 24 GAUGE, CAT 6A UTP CABLE. REFER TO SPECIFICATIONS.
4. RJ-45 TO RJ-45 CATEGORY 6A UTP PATCH CORDS. REFER TO SPECIFICATIONS FOR PATCH CORD
REQUIREMENTS.
5. CONTRACTOR SHALL TERMINATE 1 PAIR PER PORT, USING PINS 4 AND 5.
6. PROVIDE CAT 6A CABLE FOR CAMERA. TERMINATE CAT 6A CABLE WITH RJ-45 PLUG.
7. LIGHTNING PROTECTION. REFER TO 6/B406-TN300 FOR LOCATION.
8. (2) CAT 5E 25-PAIR CABLES FROM LIGHTNING PROTECTION.
#D-WAP
#D
#D-CAM
24 STRAND SM FIBER FROM
BUILDING 32 (LEG B)
TR-406-1-1
24 CAT 6A CABLES TO EXISTING TR-406-1-1
REFER TO B406-TD101 FOR EXACT LOCATION
PTZ
CCTV
CM-1
24 STRAND SM FIBER TO EXISTING TR-406-1-1
REFER TO B406-TD101 FOR EXACT LOCATION
B -T
N
EXISTING EQUIPMENT
RACK 1
EXISTING LADDER RACK
(TYP.)
SC-MPP-1
EXISTING EQUIPMENT RACK
SC-FDC-1
(24) CAT 6A CABLES FROM
TR-406-1-1
NOTES:
1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES OF MATERIALS SHOWN. THIS RISER IS SHOWN FOR CLARIFICATION OF CONNECTION(S), LOCATIONS AND CABLE TYPE. ALL INFORMATION OUTLETS ARE TYPICAL OF THE OUTLETS IN THE AREA SHOWN. REFER TO FLOOR PLANS FOR MORE SPECIFIC ROUTING INFORMATION. REFER TO SPECIFICATIONS FOR
ADDITIONAL REQUIREMENTS.
2. REFER TO TN600 FOR TECHNOLOGY EQUIPMENT SCHEDULE.
KEYNOTES:
1. CONTRACTOR TO PROVIDE (2) FIBER OPTIC PATCH CORDS FOR CONNECTIVITY TO OWNER EQUIPMENT.
2. CONTRACTOR TO PROVIDE (6) CAT 6A PATCH CORDS FOR CONNECTIVITY TO OWNER EQUIPMENT.
EXISTING TR-406-1-1
TO OWNER PROVIDED
EQUIPMENT 2
24 STRAND SM FIBER FROM
TR-406-1-1
TO OWNER PROVIDED
EQUIPMENT 1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :
B
IM
/2
V
A T o m a h
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-7
.B
.E
T
R
.r v t
/8
/2
:0
:4
P
M
B406-TN300
TELECOMMUNICATIONS ROOM
ENLARGEMENTS
EHRM INFRASTRUCTURE
UPGRADES, TOMAH, WI
TOMAH, WI
676-700
B406
02/11/2022 PDN JFK
16477
225 W WASHINGTON STREET
SUITE 2700 CHICAGO, IL 60606
312.294.0501 FAX: 312.294.0003
www.imegcorp.com # 21003227.00
N O R
HT
1/4" = 1'-0"
DATA ROOM ENLARGEMENT - TR-406-1-1
N O R
HT
1/4" = 1'-0"
LADDER RACK LAYOUT - TR-406-1-1
1" = 1'-0"
DATA RACK ELEVATION - TR-406-1-1
NOTES:
1. REFER TO 6/B406-TN300 FOR LADDER RACK LAYOUT - TR-406-1-1.
2. REFER TO 8/B406-TN300 FOR CONNECTIVITY RISER DIAGRAM - TR-406-1-1.
3. REFER TO AE211 FOR PLYWOOD INFORMATION.
4. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.
KEYNOTES:
1. REFER TO 1/TN400 BONDING BUS BAR DETAIL FOR ADDITIONAL INFORMATION.
2. CONTRACTOR TO COORDINATE FINAL RACK LOCATION WITH OWNER PRIOR TO INSTALLATION.
3. CONTRACTOR TO COORDINATE FINAL LOCATION AND FIELD OF VIEW WITH OWNER PRIOR TO
INSTALLATION.
NOTES:
1. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.
2. INSTALL BASEKET TRAY AT 7'-6" AFF.
3. REFER TO 2/B406-TN400 TECHNOLOGY CONDUIT RISER DIAGRAM FOR ADDITIONAL INFORMATION.
4. REFER TO TN503 CONDUIT AND CABLE PATHWAY DIAGRAMS FOR ADDITIONAL INFORMATION.
KEYNOTES:
1. CONTRACTOR TO COORDINATE FINAL LOCATION FOR LIGHTNING PROTECTION ENCLOSURE WITH
OWNER PRIOR TO INSTALLATION.
NOTES:
1. REFER TO 8/B406-TN300 FOR CONNECTIVITY RISER DIAGRAM - TR-406-1-1.
2. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.
KEYNOTES:
1. DEDICATED FIBER PANEL FOR 24 STRAND SM FIBER TO EXISTING TR-406-1-1.
2. DEDICATED PATCH PANEL FOR 24 CAT 6A CABLES TO EXISTING TR-406-1-1.
3. UPS AND PDU’S PROVIDED AND INSTALLED BY THE E.C. REFER TO ELECTRICAL
DRAWINGS FOR MORE INFORMATION.
NO SCALE
CONNECTIVITY RISER DIAGRAM - TR-406-1-1
N O R
HT
1/4" = 1'-0"
DATA ROOM ENLARGEMENT - EXISTING TR-406-1-1
N O R
HT
1/4" = 1'-0"
LADDER RACK LAYOUT - EXISTING TR-406-1-1
1" = 1'-0"
DATA RACK ELEVATION - EXISTING TR-406-1-1
NOTES:
1. REFER TO 4/B406-TN300 FOR CONNECTIVITY RISER DIAGRAM - EXISTING TR-406-1-1.
2. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.
KEYNOTES:
1. CONTRACTOR TO REMOVE EXISTING RACK MOUNTED DEVICES AND RETURN TO OWNER.
NO SCALE
CONNECTIVITY RISER DIAGRAM - EXISTING TR-406-1-1
NOTES:
1. REFER TO 2/B406-TN300 FOR LADDER RACK LAYOUT - EXISTING TR-406-1-1.
2. REFER TO 4/B406-TN300 FOR CONNECTIVITY RISER DIAGRAM -EXISTING TR-406-1-1.
0 4' 8'2'
0 4' 8'2'
0 4' 8'2'
0 4' 8'2'
SC-MPP-2
OWNER
PROVIDED
NETWORK
EQUIPMENT
SC-MPP-2
SC-FDC-1 SC-MPP-1
SC-BET
SC-FDC-1
SC-MPP-1
SC-FDC-1
SC-GND-1
SC-VWM-1
SC-ER-1
(TYP.)
B406-TN301
(TYP.) 1
CM-1
02-01
SC-CT-2
(TYP.)
PW-CPW-1
(2) 4" C FROM FIRST FLOOR
(2) 4" C FROM FIRST FLOOR
18"x6"
"x
18"x6"
"x
18"x6"
SC-VWM-1 SC-ER-1
(TYP.)
SC-FDC-1
SC-BLK-1
SC-FDC-1
SC-BLK-1
SC-MPP-2
SC-MPP-2
SC-MPP-2
SC-MPP-2
SC-MPP-2
SC-MPP-2
SC-MPP-2
SC-MPP-1
SC-MPP-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-HWM-1 SC-HWM-1
SC-HWM-2 SC-HWM-2
SC-HWM-2
SC-HWM-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-HWM-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
(TYP.)
NETWORK SWITCH
NETWORK SWITCH
NETWORK SWITCH
NETWORK SWITCH
NETWORK SWITCH
PDU
UPS UPS
3 3
24 STRAND SM FIBER FROM
BUILDING 32 (LEG A)
(10) CAT 5E 25-PAIRS COPPER
CABLES FROM BUILDING 32
NOTES:
1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES OF MATERIALS SHOWN.
THIS RISER IS SHOWN FOR CLARIFICATION OF CONNECTION(S), LOCATIONS AND CABLE TYPE. ALL INFORMATION OUTLETS ARE TYPICAL OF THE OUTLETS IN THE AREA SHOWN. REFER TO FLOOR PLANS FOR MORE SPECIFIC ROUTING INFORMATION. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
2. REFER TO TN600 FOR TECHNOLOGY EQUIPMENT SCHEDULE.
KEYNOTES:
1. #D INDICATES VOICE/DATA FACEPLATE CONFIGURATION. REFER TO INFORMATION OUTLET SCHEDULE ON
TN600 FOR ADDITIONAL INFORMATION. REFER TO TECHNOLOGY FLOOR PLANS AND TECHNOLOGY
EQUIPMENT SCHEDULE FOR ADDITIONAL INFORMATION.
2. FIBER OPTIC PATCH CORDS. REFER TO SPECIFICATIONS.
3. 24 GAUGE, CAT 6A UTP CABLE. REFER TO SPECIFICATIONS.
4. RJ-45 TO RJ-45 CATEGORY 6A UTP PATCH CORDS. REFER TO SPECIFICATIONS FOR PATCH CORD
REQUIREMENTS.
5. CONTRACTOR SHALL TERMINATE 1 PAIR PER PORT, USING PINS 4 AND 5.
6. PROVIDE CAT 6A CABLE FOR CAMERA. TERMINATE CAT 6A CABLE WITH RJ-45 PLUG.
7. LIGHTNING PROTECTION. REFER TO 6/B406-TN300 FOR LOCATION.
8. (4) CAT 5E 25-PAIR CABLES FROM LIGHTNING PROTECTION.
#D-WAP
#D
#D-CAM
24 STRAND SM FIBER FROM
BUILDING 32 (LEG B)
24 CAT 6A CABLES TO EXISTING TR-406-2-1
REFER TO B406-TD102 FOR EXACT LOCATION
24 CAT 6A CABLES TO SECOND FLOOR EXISTING HILL
ROM ROOM. REFER TO B406-TD102 FOR EXACT
LOCATION
TR-406-1-1
PTZ
CCTV
CM-1
TR-406-2-1
24 STRAND SM FIBER TO EXISTING TR-406-2-1
REFER TO B406-TD102 FOR EXACT LOCATION
B -T
N
EXISTING EQUIPMENT
RACK
EXISTING LADDER RACK (TYP.)
EXISTING EQUIPMENT RACK
SC-FDC-1
SC-MPP-1
(24) CAT 6A CABLES FROM
TR-406-2-1
NOTES:
1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES OF MATERIALS SHOWN.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .