Atch 14 - Telecommunications 3 of 4.pdf

PDF 16 MB Posted

Attached to
Y1AZ--EHRM Infrastructure Upgrades Construction - Tomah Federal contract opportunity
Solicitation number
36C77622B0031
Issued by
Department of Veterans Affairs Technology Acquisition Center Austin

About this file

This federal contract opportunity solicitation involves infrastructure upgrades and renovations at the Tomah VA Medical Center in Wisconsin. The solicitation seeks contractors to perform electrical, HVAC, communication, physical security, and fiber infrastructure upgrades across multiple buildings on campus. Additional requirements include modifying impacted roads, walks, grading and drainage, hazardous material abatement, and data center WAN updates. The solicitation was issued by the Department of Veterans Affairs Technology Acquisition Center located in Austin, Texas.

View the file

Other files for this federal contract opportunity

Other files attached to Y1AZ--EHRM Infrastructure Upgrades Construction - Tomah, newest first.
File Type Posted
36C77622B0031 0005.pdf PDF
Follow-up Questions and Responses 7-26-22.pdf PDF
36C77622B0031 0004.pdf PDF
36C77622B0031 0003.pdf PDF
Atch 28 - Construction Wage Rates - Monroe - 7-15-22.pdf PDF
Technical Questions - LATE - Tomah 7-20-22.pdf PDF
OIT-StdTelecomSpacesPgs64-67.pdf PDF
Atch 28 - Construction Wage Rates - Monroe - 6-17-22.pdf PDF
36C77622B0031 0002.pdf PDF
Technical Questions - FINAL - Tomah 7-6-22.pdf PDF
Site Visit Sign-in Sheet - Tomah 6-14-22.pdf PDF
36C77622B0031 0001.pdf PDF
Atch 6 - General.pdf PDF
Atch 13 - Telecommunications 2 of 4.pdf PDF
Atch 16 - Electrical 1 of 4.pdf PDF
Atch 21 - Mechanical 2 of 4.pdf PDF
36C77622B0031 - 5-25-22.pdf PDF
Atch 2 - Specs Division 21-23.pdf PDF
Atch 15 - Telecommunications 4 of 4.pdf PDF
Atch 18 - Electrical 3 of 4.pdf PDF
Atch 19 - Electrical 4 of 4.pdf PDF
Atch 24 - Appendix A-B Specs on TOC.pdf PDF
Atch 1 - Specs Division 00-10.pdf PDF
Atch 8 - Civil 2 of 2.pdf PDF
Atch 10 - Architectural 2 of 2.pdf PDF
Atch 12 - Telecommunications 1 of 4.pdf PDF
Atch 17 - Electrical 2 of 4.pdf PDF
Atch 20 - Mechanical 1 of 4.pdf PDF
Atch 22 - Mechanical 3 of 4.pdf PDF
Atch 23 - Mechanical 4 of 4.pdf PDF
Atch 25 - Appendix C-D Specs on TOC.pdf PDF
Atch 27 - Limitations on Subcontracting - Construction.docx DOCX document
Atch 28 - Construction Wage Rates - Monroe - 4-29-22.pdf PDF
Atch 29 - Contractor Safety - Environmental Form.docx DOCX document
Atch 3 - Specs Division 26-28.pdf PDF
Atch 4 - Specs Division 31-33.pdf PDF
Atch 5 - Sheet Index - EHRM Upgrades.pdf PDF
Atch 7 - Civil 1 of 2.pdf PDF
Atch 9 - Architectural 1 of 2.pdf PDF
Atch 26 - COVID-19 Safety Protocols 12-14-21.pdf PDF
Atch 30 - Site Visit - Map.pdf PDF
Atch 11 - Hazmat.pdf PDF
Show all 42

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ELEV.

10500

10508

1050110599

10510

10512

10505

10511

10513

10515

10517

10518

10519

10520

10522

10521

10524

10526

10523

10525

10527

10528

01B 10B

11B

15B

18B

20B

19B

24B

23B

28B

10597

10596

10589

10591

10592

10588

10590

10585

10586

10577

10581

10583

UP

UP

1D-CAM

1D-CAM

1D-CAM

D

-C A

M

1D-CAM

1D-WAP

D 1

D

3D

1D

3D

1D

3D

1D

3D

1D

3D

1D

1D-CAM1D-CAM

1D-WAP

D

D

3D

1D

3D

1D

3D

1D

3D

1D

3D

1D

3D

1D

3D

1D

3D

1D

1D-CAM

1D-GWAP

1D-WAP

1D-GWAP

1D-WAP

1D-GWAP

1D-CAM

1D-WAP

D

-C A

M

D

3D

1D

1D-WAP

1D-CAM

V

1D -C

A M

1D-WAP

D

D

D

D

V

1D-CAM

1D-GWAP

1D-WAP

1V

D

D

D

1D-CAM

1D-CAM

D

-C A

M

1D-WAP

D

-C A

M

1D-CAM

1D

V

1D-WAP

1D-WAP

1D-WAP

D

4D

1D-CAM

1D-WAP

1D-CAM

1D-WAP

1D-CAM

1D-CAM

1D-CAM

1D-GWAP

1D-CAM

1D-WAP

1D-CAM

1D-WAP

1D-CAM

1D-CAM

P T

Z

C C

T V

TR-405-1-1

FROM BUILDING 404 TO

ROOM 10592

EXISTING (2) 6" CONDUITS

IN TUNNEL

(1) 6" CONDUIT - (3) B LEG FIBERS

(1) 6" CONDUIT - (6) 25-PAIR CAT 5E

EXISTING 1X4 DUCTBANK

FROM 10592

EXISTING (1) 4" CONDUIT - (3) A LEG FIBERS

EXISTING (3) 4" CONDUITS - SPARE

B405-TN300

B405-TN300

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :

B

IM

/2

V

A T o m a h

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-7

.B

.E

T

R

.r v t

/8

/2

:0

:4

P

M

B405-TN101

FIRST FLOOR -

TELECOMMUNICATIONS

EHRM INFRASTRUCTURE

UPGRADES, TOMAH, WI

TOMAH, WI

676-21-700

B405

02/11/2022 PDN JFK

16477

225 W WASHINGTON STREET

SUITE 2700 CHICAGO, IL 60606

312.294.0501 FAX: 312.294.0003

www.imegcorp.com # 21003227.00

N O R

HT

1/8" = 1'-0"

FIRST FLOOR - TELECOMMUNICATIONS

TECHNOLOGY SHEET NOTES:

1. REFER TO TN000 TECHNOLOGY COVERSHEET

FOR TECHNOLOGY GENERAL NOTES,

TECHNOLOGY INSTALLATION NOTES AND

SYMBOL LIST.

2. ALL INFORMATION OUTLETS ON THIS SHEET

SHALL BE SERVED FROM EXISTING TR-405-1-1.

3. REFER TO TN600 FOR GENERAL TECHNOLOGY

EQUIPMENT SCHEDULE.

4. INFORMATION OUTLETS ARE SHOWN FOR

REFERENCE ONLY. RE-CABLING THIS FLOOR IS

NOT REQUIRED.

5. CONTRACTOR TO FIELD VERIFY CONDUIT

RISER ROUTE WITH OWNER PRIOR TO

INSTALLATION.

0 8' 16'4'

Revisions: Date:

20506

ELEV.

Lounge

20510

20508

20501

20500

20504

20584

84B

20583

20586

20585

83B

86B

20588

20587

20581

81B

20579

10B 20512

20511

11B

20513

20515

15B

20517

20519

20521

19B

20518

20516

20520

18B

20522

20524

22B 20523

20525

23B

20527

20599

20598

20595

20596

20593

20591

20589

87B

20577

20535

20537

37B20539

20541

20543 20545

77B 43B

45B

41B

39B

20544 20546

20503

20505

20547

93B

D

1D

1D

1D

1D

1D

1D

1D

D

3D

3D

3D

3D

3D

3D

3D

D

4D 4D 4D 4D 4D 4D

4D 4D 4D 4D

4D 4D

4D

3D

D

1D

1D

1D

1D

1D

1D

1D

1D

4D 4D 4D

4D

3D

3D

3D

3D

3D

3D

3D

3D

D

D

D

D

D

D

D

D

D

D

1D

1D

1D

1D

3D

3D

3D

4D 4D

1D

1D

1D

1D

3D

3D

3D

3D

1D

D

D

D

D

1D-CAM

1D-CAM

1D-WAP

1D-GWAP

1D-WAP 1D-WAP

1D-GWAP

1D-CAM

1D-WAP

1D-CAM

1D-GWAP

1D-CAM 1D-WAP

1D-WAP

1D-GWAP

1D-WAP

1D-WAP

1D-GWAP

1D-CAM

1D-WAP

1D-CAM

1D-WAP

1D-WAP

1D-CAM

1D-WAP

1D-GWAP

1D-WAP

1D-CAM

1D-WAP

1D-CAM

1D-WAP

1D-CAM

1D-CAM

1D-WAP

1D-WAP

1D-GWAP

1D-GWAP

1D-WAP

1D-WAP

1D-WAP

1D-CAM

1D-WAP

4D

1D-CAM

P T

Z

C C

T V

TR-405-2-1

B405-TN301

B405-TN301

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :

B

IM

/2

V

A T o m a h

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-7

.B

.E

T

R

.r v t

/8

/2

:0

:5

P

M

B405-TN102

SECOND FLOOR -

TELECOMMUNICATIONS

EHRM INFRASTRUCTURE

UPGRADES, TOMAH, WI

TOMAH, WI

676-21-700

B405

02/11/2022 PDN JFK

16477

225 W WASHINGTON STREET

SUITE 2700 CHICAGO, IL 60606

312.294.0501 FAX: 312.294.0003

www.imegcorp.com # 21003227.00

N O R

HT

1/8" = 1'-0"

SECOND FLOOR - TELECOMMUNICATIONS

TECHNOLOGY SHEET NOTES:

1. REFER TO TN000 TECHNOLOGY COVERSHEET

FOR TECHNOLOGY GENERAL NOTES,

TECHNOLOGY INSTALLATION NOTES AND

SYMBOL LIST.

2. ALL INFORMATION OUTLETS ON THIS SHEET

SHALL BE SERVED FROM EXISTING TR-405-2-1.

3. REFER TO TN600 FOR GENERAL TECHNOLOGY

EQUIPMENT SCHEDULE.

4. INFORMATION OUTLETS ARE SHOWN FOR

REFERENCE ONLY. RE-CABLING THIS FLOOR IS

NOT REQUIRED.

5. CONTRACTOR TO FIELD VERIFY CONDUIT

RISER ROUTE WITH OWNER PRIOR TO

INSTALLATION.

CORR.

3C01

CORR.

3C06

CORR.

3C03

CORR.

3C03

ELEV.

EL01

CORR.

3C05

CORR.

3C07

CORR.

3C04

CORR.

3C08

CORR.

3C09

CORR.

3C10

STAIR 22

3S22

STAIR 23

3S23

30599 30501 30503

30505

30512

30511

30513

30504 30506

30516

30508

30515

30517

30519

30521

30523

30525

30527

30518

30520

30522

30524

3053730539

30541

3054330545

30547 30535

30577

30579

30581

30546

30584

30583

30586

30585

30587

30588

30589

30591

30593

30596

30595

30598 30500

12B

11B

15B

18B

19B

22B

23B

37B

39B

41B

43B

45B

81B

84B

83B

86B

87B

93B

DN

DN

4D

4D

1D

1D

1D

1D

4D

4D

4D

4D

D

4D 4D 4D 4D

4D 4D

1D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D 4D 4D

1D

1D

1D

1D

1D

1D

1D

1D 4D

1D

4D

1D

1D

1D

4D

4D

4D

D

D

D

D

D

4D 1D

4D

4D

4D

1D

1D

4D

D

1D-WAP

D

-C A

M

1D-WAP 1D-CAM

1D-CAM

1D-WAP

1D-CAM

1D-CAM

1D-GWAP

1D-WAP

1D-WAP

1D-GWAP

1D-WAP

1D-WAP

1D-CAM

1D-CAM

1D-WAP

1D-CAM

1D-WAP

1D-WAP 1D-GWAP

1D-WAP

1D-WAP

1D-CAM

1D-WAP

1D-CAM1D-CAM

1D-GWAP

1D-CAM

1D-WAP

1D-WAP

1D-GWAP

1D-WAP

1D-WAP

1D-CAM

1D-GWAP

1D-CAM

1D-WAP

1D-WAP

1D-CAM

1D-CAM

1D-GWAP

1D-CAM

1D-CAM

1D-WAP

1D-WAP

4D

1D-CAM

P T

Z

C C

T V

TR-405-3-1

B405-TN302

B405-TN302

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :

B

IM

/2

V

A T o m a h

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-7

.B

.E

T

R

.r v t

/8

/2

:0

:5

P

M

B405-TN103

THIRD FLOOR -

TELECOMMUNICATIONS

EHRM INFRASTRUCTURE

UPGRADES, TOMAH, WI

TOMAH, WI

676-21-700

B405

02/11/2022 PDN JFK

16477

225 W WASHINGTON STREET

SUITE 2700 CHICAGO, IL 60606

312.294.0501 FAX: 312.294.0003

www.imegcorp.com # 21003227.00

N O R

HT

1/8" = 1'-0"

THIRD FLOOR - TELECOMMUNICATIONS

TECHNOLOGY SHEET NOTES:

1. REFER TO TN000 TECHNOLOGY COVERSHEET

FOR TECHNOLOGY GENERAL NOTES,

TECHNOLOGY INSTALLATION NOTES AND

SYMBOL LIST.

2. ALL INFORMATION OUTLETS ON THIS SHEET

SHALL BE SERVED FROM EXISTING TR-405-3-1.

3. REFER TO TN600 FOR GENERAL TECHNOLOGY

EQUIPMENT SCHEDULE.

4. INFORMATION OUTLETS ARE SHOWN FOR

REFERENCE ONLY. RE-CABLING THIS FLOOR IS

NOT REQUIRED.

5. CONTRACTOR TO FIELD VERIFY CONDUIT

RISER ROUTE WITH OWNER PRIOR TO

INSTALLATION.

P T

Z

C C

T V

1D-CAM

EXISTING

PATCH PANEL

OWNER

PROVIDED

NETWORK

EQUIPMENT

SC-MPP-2

SC-FDC-1

SC-BET

EXISTING WALL RACK

EXISTING ACCESS CONTROL

CABINET

EXISTING WIRE MANAGER

(TYP.)

EXISTING EQUIPMENT RACK

(TYP.)

B -T

N

EXISTING TV

AMPLIFIER

EXISTING LADDER RACK

(TYP.)

EXISTING VERTICAL LADDER RACK

EXISTING CONDUITS

(4) 4" C

(2) 6" C

EXST. WIRE MANAGER

EXST. WIRE MANAGER

EXST. WIRE MANAGER

EXST. WIRE MANAGER

EXST. WIRE MANAGER

EXST. WIRE MANAGER

EXST. SWITCH

EXST. WIRE MANAGER

EXST. PATCH PANEL

EXST. PATCH PANEL

EXST. PATCH PANEL

EXST. PATCH PANEL

EXST. FIBER PANEL

EXST. FIBER PANEL

EXST. WIRE MANAGER

EXST. EQUIPMENT

EXISTING WIRE MANAGER (TYP.)

EXISTING EQUIPMENT RACK (TYP.)

EXISTING WALL RACK

EXISTING ACCESS CONTROL

CABINET

B -T

N

SC-VWM-1

SC-ER-1

EXISTING TV

AMPLIFIER

(TYP.)

(TYP.)

SC-TTB (TYP.)

SC-GND-1 1

2CM-1

01-01

EXISTING VERTICAL LADDER RACK

EXISTING CONDUITS

(4) 4" C

(2) 6" C

SC-CT-2

(TYP.)

18"x6"

"x

"x

"x

18"x6"

SC-BET

(TYPICAL OF 3)

EXST. WIRE MANAGER

EXST. WIRE MANAGER

EXST. WIRE MANAGER

EXST. WIRE MANAGER

EXST. WIRE MANAGER

EXST. WIRE MANAGER

EXST. SWITCH

EXST. WIRE MANAGER

EXST. PATCH PANEL

EXST. PATCH PANEL

EXST. PATCH PANEL

EXST. PATCH PANEL

EXST. FIBER PANEL

EXST. FIBER PANEL

EXST. WIRE MANAGER

EXST. EQUIPMENT

SC-VWM-1 SC-ER-1

(TYP.)(TYP.)

SC-FDC-1

SC-MPP-2

PDU

UPS UPS

3 3

24 STRAND SM FIBER FROM

BUILDING 32 (LEG A)

(6) CAT 5E 25-PAIRS COPPER

CABLES FROM BUILDING 32

NOTES:

1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES OF MATERIALS SHOWN. THIS RISER IS SHOWN FOR CLARIFICATION OF CONNECTION(S), LOCATIONS AND CABLE TYPE. ALL INFORMATION OUTLETS ARE TYPICAL OF THE OUTLETS IN THE AREA SHOWN. REFER TO FLOOR PLANS FOR MORE SPECIFIC ROUTING INFORMATION. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

2. REFER TO TN600 FOR TECHNOLOGY EQUIPMENT SCHEDULE.

KEYNOTES:

1. FIBER OPTIC PATCH CORDS. REFER TO SPECIFICATIONS FOR PATCH CORD REQUIREMENTS.

2. RJ-45 TO RJ-45 CATEGORY 6A UTP PATCH CORDS. REFER TO SPECIFICATIONS FOR PATCH CORD

REQUIREMENTS.

3. CONTRACTOR SHALL TERMINATE 1 PAIR PER PORT, USING PINS 4 AND 5.

4. LIGHTNING PROTECTION. REFER TO 5/B405-TN300 FOR LOCATION.

5. (2) CAT 5E 25-PAIR CABLES FROM LIGHTNING PROTECTION.

6. 24 GAUGE, CAT 6A UTP CABLE. REFER TO SPECIFICATIONS.

7. PROVIDE CAT 6A CABLE FOR CAMERA. TERMINATE CAT 6A CABLE WITH RJ-45 PLUG.

24 STRAND SM FIBER FROM

BUILDING 32 (LEG B)

TR-405-1-1

PTZ

CCTV ##-##

CM-1

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :

B

IM

/2

V

A T o m a h

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-7

.B

.E

T

R

.r v t

/8

/2

:0

:5

P

M

B405-TN300

TELECOMMUNICATIONS ROOM

ENLARGEMENTS

EHRM INFRASTRUCTURE

UPGRADES, TOMAH, WI

TOMAH, WI

676-21-700

B405

02/11/2022 PDN JFK

16477

225 W WASHINGTON STREET

SUITE 2700 CHICAGO, IL 60606

312.294.0501 FAX: 312.294.0003

www.imegcorp.com # 21003227.00

N O R

HT

1/4" = 1'-0"

DATA ROOM ENLARGEMENT - EXISTING TR-405-1-1

N O R

HT

1/4" = 1'-0"

LADDER RACK LAYOUT - EXISTING TR-405-1-1

1" = 1'-0"

DATA RACK ELEVATION - EXISTING TR-405-1-1

N O R

HT

1/4" = 1'-0"

DATA ROOM ENLARGEMENT - TR-405-1-1

N O R

HT

1/4" = 1'-0"

LADDER RACK LAYOUT - TR-405-1-1

5 1" = 1'-0"

DATA RACK ELEVATION - TR-405-1-1

NO SCALE

CONNECTIVITY RISER DIAGRAM - TR-405-1-1

NOTES:

1. REFER TO 2/B405-TN300 FOR LADDER RACK LAYOUT - EXISTING TR-405-1-1.

2. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.

KEYNOTES:

1. REMOVE EXISTING PATCH PANELS FROM 2-POST RACK WITHOUT REMOVING HORIZONTAL CABLES. CONTRACTOR TO REMOVE EXISTING 2-POST RACKS. RACK MOUNTED DEVICES TO BE REMOVED AND PROTECTED FOR RE-INSTALLATION.

EXISTING EQUIPMENT RACKS TO REMAIN UNTIL ALL RACK MOUNTED DEVICES RELOCATED TO NEW SC-ER-1.

NOTES:

1. REFER TO 5/B405-TN300 FOR LADDER RACK LAYOUT - TR-405-1-1.

2. REFER TO 7/B405-TN300 FOR CONNECTIVITY RISER DIAGRAM - TR-405-1-1.

3. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.

KEYNOTES:

1. REFER TO 1/TN400 BONDING BUS BAR DETAIL FOR ADDITIONAL INFORMATION.

2. REFER TO AE211 FOR PLYWOOD INFORMATION.

3. CONTRACTOR TO COORDINATE FINAL RACK LOCATION WITH OWNER PRIOR TO INSTALLATION.

4. CONTRACTOR TO COORDINATE FINAL LOCATION AND FIELD OF VIEW WITH OWNER PRIOR TO

INSTALLATION.

NOTES:

1. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.

KEYNOTES:

1. REMOVE EXISTING PATCH PANELS FROM 2-POST RACKS WITHOUT REMOVING HORIZONTAL CABLES. REMOVE

2- POST RACKS AND REPLACE THEM WITH SC-ER-1.

NOTES:

1. REFER TO 7/B405-TN300 FOR CONNECTIVITY RISER DIAGRAM - TR-405-1-1.

2. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.

KEYNOTES:

1. REINSTALL EXISTING PATCH PANELS ON SC-ER-1.

2. CONTRACTOR TO TEST AND CERTIFY ALL HORIZONTAL CABLING ON THIS PATCH

PANEL AFTER INSTALLATION ON SC-ER-1.

3. UPS AND PDU’S PROVIDED AND INSTALLED BY THE E.C. REFER TO ELECTRICAL

DRAWINGS FOR MORE INFORMATION.

NOTES:

1. INSTALL BASKET TRAY AT 7'-6" AFF.

2. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.

3. REFER TO 2/B405-TN400 TECHNOLOGY CONDUIT RISER DIAGRAM.

4. REFER TO TN503 CONDUIT AND CABLE PATHWAY DIAGRAMS FOR ADDITIONAL

INFORMATION.

KEYNOTES:

1. CONTRACTOR TO COORDINATE FINAL LOCATION FOR LIGHTNING PROTECTION

ENCLOSURE WITH OWNER PRIOR TO INSTALLATION.

0 4' 8'2' 0 4' 8'2'

0 4' 8'2'

0 4' 8'2'

STAMP

Z

C C

T V

1D-CAM

EXISTING

PATCH PANEL

OWNER

PROVIDED

NETWORK

EQUIPMENT

SC-MPP-2

SC-FDC-1

SC-BET

EXISTING ACCESS CONTROL

CABINET

EXISTING WALL RACK

EXISTING CABINET

EXISTING WIRE MANAGER

(TYP.)

EXISTING EQUIPMENT RACK

(TYP.)

EXISTING GROUND BAR

B -T

N

EXISTING TV AMPLIFIER

EXISTING LADDER RACK

(TYP.)

EXISTING WIRE MANAGER

(TYP.)

EXISTING EQUIPMENT RACK

(TYP.)

NETWORK SWITCH

NETWORK SWITCH

EXISTING PAGING

EQUIPMENT

EXISTING NURSE CALL

EQUIPMENT

EXISTING NURSE CALL

EQUIPMENT

EXISTING NURSE CALL

EQUIPMENT

EXISTING EQUIPMENT

EXISTING EQUIPMENT

EXST. WIRE MANAGER

EXST. WIRE MANAGER

EXST. WIRE MANAGER

EXST. WIRE MANAGER

EXST. WIRE MANAGER

EXST. WIRE MANAGER

EXST. PATCH PANEL

EXST. PATCH PANEL

EXST. PATCH PANEL

EXST. PATCH PANEL

EXST. PATCH PANEL

EXST. FIBER PANEL

EXISTING PAGING

EQUIPMENT

B -T

N

SC-VWM-1

(TYP.)

EXISTING ACCESS CONTROL

CABINET

EXISTING WALL RACK

EXISTING CABINET

EXISTING GROUND BAR

SC-ER-1

EXISTING TV AMPLIFIER

SC-TTB

(TYP.)

(TYP.)

CM-1

02-01

SC-CT-2

(TYP.)

18"x6"

"x

"x

"x

18"x6"

SC-VWM-1

(TYP.)

SC-ER-1

(TYP.)

NETWORK SWITCH

NETWORK SWITCH

EXISTING PAGING

EQUIPMENT

EXISTING EQUIPMENT

EXISTING EQUIPMENT

EXST. WIRE MANAGER

EXST. WIRE MANAGER

EXST. WIRE MANAGER

EXST. WIRE MANAGER

EXST. WIRE MANAGER

EXST. WIRE MANAGER

EXST. PATCH PANEL

EXST. PATCH PANEL

EXST. PATCH PANEL

EXST. PATCH PANEL

EXST. PATCH PANEL

EXST. FIBER PANEL

SC-FDC-1

SC-MPP-2

EXISTING PAGING

EQUIPMENT

EXISTING NURSE CALL

EQUIPMENT

EXISTING NURSE CALL

EQUIPMENT

EXISTING NURSE CALL

EQUIPMENT

PDU

UPS UPS

5 5

24 STRAND SM FIBER FROM

BUILDING 32 (LEG A)

(6) CAT 5E 25-PAIRS COPPER

CABLES FROM BUILDING 32

NOTES:

1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES OF MATERIALS SHOWN. THIS RISER IS SHOWN FOR CLARIFICATION OF CONNECTION(S), LOCATIONS AND CABLE TYPE.

ALL INFORMATION OUTLETS ARE TYPICAL OF THE OUTLETS IN THE AREA SHOWN. REFER TO FLOOR PLANS FOR MORE SPECIFIC ROUTING INFORMATION. REFER TO SPECIFICATIONS FOR ADDITIONAL

REQUIREMENTS.

2. REFER TO TN600 FOR TECHNOLOGY EQUIPMENT SCHEDULE.

KEYNOTES:

1. FIBER OPTIC PATCH CORDS. REFER TO SPECIFICATIONS FOR PATCH CORD REQUIREMENTS.

2. RJ-45 TO RJ-45 CATEGORY 6A UTP PATCH CORDS. REFER TO SPECIFICATIONS FOR PATCH CORD

REQUIREMENTS.

3. CONTRACTOR SHALL TERMINATE 1 PAIR PER PORT, USING PINS 4 AND 5.

4. LIGHTNING PROTECTION. REFER TO 5/B405-TN300 FOR LOCATION.

5. (2) CAT 5E 25-PAIR CABLES FROM LIGHTNING PROTECTION.

6. 24 GAUGE, CAT 6A UTP CABLE. REFER TO SPECIFICATIONS.

7. PROVIDE CAT 6A CABLE FOR CAMERA. TERMINATE CAT 6A CABLE WITH RJ-45 PLUG.

24 STRAND SM FIBER FROM

BUILDING 32 (LEG B)

TR-405-2-1

TR-405-1-1

PTZ

CCTV ##-##

CM-1

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :

B

IM

/2

V

A T o m a h

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-7

.B

.E

T

R

.r v t

/8

/2

:0

:0

P

M

B405-TN301

TELECOMMUNICATIONS ROOM

ENLARGEMENTS

EHRM INFRASTRUCTURE

UPGRADES, TOMAH, WI

TOMAH, WI

676-21-700

B405

02/11/2022 PDN JFK

16477

225 W WASHINGTON STREET

SUITE 2700 CHICAGO, IL 60606

312.294.0501 FAX: 312.294.0003

www.imegcorp.com # 21003227.00

N O R

HT

1/4" = 1'-0"

DATA ROOM ENLARGEMENT - EXISTING TR-405-2-1

N O R

HT

1/4" = 1'-0"

LADDER RACK LAYOUT - EXISTING TR-405-2-1

1" = 1'-0"

DATA RACK ELEVATION - EXISTING TR-405-2-1

NOTES:

1. REFER TO 2/B405-TN301 FOR LADDER RACK LAYOUT - EXISTING TR-405-2-1.

2. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.

KEYNOTES:

1. REMOVE EXISTING PATCH PANELS FROM 2-POST RACK WITHOUT REMOVING HORIZONTAL CABLES. CONTRACTOR TO REMOVE EXISTING 2-POST RACKS. RACK MOUNTED DEVICES TO BE REMOVED AND PROTECTED FOR RE-INSTALLATION.

EXISTING EQUIPMENT RACKS TO REMAIN UNTIL ALL RACK MOUNTED DEVICES RELOCATED TO NEW SC-ER-1.

NOTES:

1. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.

KEYNOTES:

1. REMOVE EXISTING PATCH PANELS FROM 2-POST RACKS WITHOUT REMOVING HORIZONTAL CABLES. REMOVE

2- POST RACKS AND REPLACE THEM WITH SC-ER-1.

2. EXISTING PAGING EQUIPMENT TO BE REMOVED FROM 2-POST RACK FOR INSTALLATION INTO SC-ER-1 WITHOUT

REMOVING OR RE-CABLING EXISTING CABLES.

3. EXISTING NURSE CALL EQUIPMENT TO BE REMOVED FROM 2-POST RACK FOR INSTALLATION INTO SC-ER-1

WITHOUT REMOVING OR RE-CABLING EXISTING CABLES.

N O R

HT

1/4" = 1'-0"

DATA ROOM ENLARGEMENT - TR-405-2-1

N O R

HT

1/4" = 1'-0"

LADDER RACK LAYOUT - TR-405-2-1

1" = 1'-0"

DATA RACK ELEVATION - TR-405-2-1

NO SCALE

CONNECTIVITY RISER DIAGRAM - TR-405-2-1

NOTES:

1. REFER TO 5/B405-TN301 FOR LADDER RACK LAYOUT - TR-405-2-1.

2. REFER TO 7/B405-TN301 FOR CONNECTIVITY RISER DIAGRAM - TR-405-2-1.

3. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.

KEYNOTES:

1. REFER TO AE211 FOR PLYWOOD INFORMATION.

2. CONTRACTOR TO COORDINATE FINAL RACK LOCATION WITH OWNER PRIOR TO INSTALLATION.

3. CONTRACTOR TO COORDINATE FINAL LOCATION AND FIELD OF VIEW WITH OWNER PRIOR TO

INSTALLATION.

NOTES:

1. REFER TO 7/B405-TN301 FOR CONNECTIVITY RISER DIAGRAM - TR-405-2-1.

2. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.

KEYNOTES:

1. REINSTALL EXISTING PATCH PANELS ON SC-ER-1.

2. CONTRACTOR TO TEST AND CERTIFY ALL HORIZONTAL CABLING ON THIS PATCH

PANEL AFTER INSTALLATION ON SC-ER-1.

3. REINSTALL PAGING SYSTEM IN SC-ER-1. TEST AND CERTIFY SYSTEM FOR COMPLETE

OPERATION.

4. REINSTALL NURSE CALL SYSTEM IN SC-ER-1. TEST AND CERTIFY SYSTEM FOR

COMPLETE OPERATION.

5. UPS AND PDU’S PROVIDED AND INSTALLED BY THE E.C. REFER TO ELECTRICAL

DRAWINGS FOR MORE INFORMATION.

NOTES:

1. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.

2. INSTALL BASKET TRAY AT 7'-6" AFF.

3. REFER TO 2/B405-TN400 TECHNOLOGY CONDUIT RISER DIAGRAM.

4. REFER TO TN503 CONDUIT AND CABLE PATHWAY DIAGRAMS FOR ADDITIONAL

INFORMATION.

0 4' 8'2' 0 4' 8'2'

0 4' 8'2'

0 4' 8'2'

Z

C C

T V

1D-CAM

EXISTING

PATCH PANEL

OWNER

PROVIDED

NETWORK

EQUIPMENT

SC-MPP-2

SC-FDC-1

SC-BET

B -T

N

3EXISTING WALL RACK

EXISTING WIRE MANAGER

(TYP.)

EXISTING EQUIPMENT RACK

(TYP.)

EXISTING GROUND BAR

EXISTING LADDER RACK

(TYP.)

EXISTING WIRE MANAGER

(TYP.)

EXISTING EQUIPMENT RACK

(TYP.)

EXISTING NURSE CALL

EQUIPMENT

EXISTING NURSE CALL

EQUIPMENT

EXISTING NURSE CALL

EQUIPMENT

EXISTING FIBER

PANEL

EXISTING FIBER

PANEL

EXISTING WIRE

MANAGER

EXISTING WIRE

MANAGER

EXISTING WIRE

MANAGER

EXISTING WIRE

MANAGER

EXISTING WIRE

MANAGER

EXISTING WIRE

MANAGER

EXISTING WIRE

MANAGER

EXISTING PATCH

PANEL

EXISTING PATCH

PANEL

EXISTING PATCH

PANEL

EXISTING PATCH

PANEL

EXISTING PATCH

PANEL

EXISTING WIRE

MANAGER

EXISTING EQUIPMENT

EXISTING EQUIPMENT

B -T

N

SC-VWM-1

(TYP.)

SC-ER-1

(TYP.)

EXISTING WALL RACK

EXISTING GROUND BAR

SC-TTB

(TYP.)

CM-1

03-01

SC-CT-2

(TYP.)

18"x6"

"x

"x

"x

18"x6"

EXISTING NURSE CALL

EQUIPMENT

EXISTING NURSE CALL

EQUIPMENT

EXISTING NURSE CALL

EQUIPMENT

EXISTING FIBER

PANEL

EXISTING FIBER

PANEL

EXISTING WIRE

MANAGER

EXISTING WIRE

MANAGER

EXISTING WIRE

MANAGER

EXISTING WIRE

MANAGER

EXISTING WIRE

MANAGER

EXISTING WIRE

MANAGER

EXISTING WIRE

MANAGER

EXISTING PATCH

PANEL

EXISTING PATCH

PANEL

EXISTING PATCH

PANEL

EXISTING PATCH

PANEL

EXISTING PATCH

PANEL

EXISTING WIRE

MANAGER

EXISTING EQUIPMENT

EXISTING EQUIPMENT

SC-FDC-1

SC-MPP-2

SC-VWM-1 SC-ER-1

(TYP.) (TYP.)

1 2

1 2

1 2

1 2

1 2

PDU

UPS UPS

4 4

24 STRAND SM FIBER FROM

BUILDING 32 (LEG A)

(6) CAT 5E 25-PAIRS COPPER

CABLES FROM BUILDING 32

NOTES:

1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES OF MATERIALS SHOWN. THIS RISER IS SHOWN FOR CLARIFICATION OF CONNECTION(S), LOCATIONS AND CABLE TYPE. ALL INFORMATION OUTLETS ARE TYPICAL OF THE OUTLETS IN THE AREA SHOWN. REFER TO FLOOR PLANS FOR MORE SPECIFIC ROUTING INFORMATION. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

2. REFER TO TN600 FOR TECHNOLOGY EQUIPMENT SCHEDULE.

KEYNOTES:

1. FIBER OPTIC PATCH CORDS. REFER TO SPECIFICATIONS.

2. RJ-45 TO RJ-45 CATEGORY 6A UTP PATCH CORDS. REFER TO SPECIFICATIONS FOR PATCH CORD

REQUIREMENTS.

3. CONTRACTOR SHALL TERMINATE 1 PAIR PER PORT, USING PINS 4 AND 5.

4. LIGHTNING PROTECTION. REFER TO 5/B405-TN300 FOR LOCATION.

5. (2) CAT 5E 25-PAIR CABLES FROM LIGHTNING PROTECTION.

6. 24 GAUGE, CAT 6A UTP CABLE. REFER TO SPECIFICATIONS.

7. PROVIDE CAT 6A CABLE FOR CAMERA. TERMINATE CAT 6A CABLE WITH RJ-45 PLUG.

24 STRAND SM FIBER FROM

BUILDING 32 (LEG B)

EXISTING TR-405-3-1

TR-405-1-1

PTZ

CCTV ##-##

CM-1

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :

B

IM

/2

V

A T o m a h

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-7

.B

.E

T

R

.r v t

/8

/2

:0

:0

P

M

B405-TN302

TELECOMMUNICATIONS ROOM

ENLARGEMENTS

EHRM INFRASTRUCTURE

UPGRADES, TOMAH, WI

TOMAH, WI

676-21-700

B405

02/11/2022 PDN JFK

16477

225 W WASHINGTON STREET

SUITE 2700 CHICAGO, IL 60606

312.294.0501 FAX: 312.294.0003

www.imegcorp.com # 21003227.00

N O R

HT

1/4" = 1'-0"

DATA ROOM ENLARGEMENT - EXISTING TR-405-3-1

N O R

HT

1/4" = 1'-0"

LADDER RACK LAYOUT - EXISTING TR-405-3-1

1" = 1'-0"

DATA RACK ELEVATION - EXISTING TR-405-3-1

N O R

HT

1/4" = 1'-0"

DATA ROOM ENLARGEMENT - TR-405-3-1

N O R

HT

1/4" = 1'-0"

LADDER RACK LAYOUT - TR-405-3-1

1" = 1'-0"

DATA RACK ELEVATION - TR-405-3-1

NO SCALE

CONNECTIVITY RISER DIAGRAM - TR-405-3-1

NOTES:

1. REFER TO 2/B405-TN302 FOR LADDER RACK LAYOUT - EXISTING TR-405-3-1.

2. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.

KEYNOTES:

1. REMOVE EXISTING PATCH PANELS FROM 2-POST RACK WITHOUT REMOVING HORIZONTAL CABLES. CONTRACTOR TO REMOVE EXISTING 2-POST RACKS. RACK MOUNTED DEVICES TO BE REMOVED AND PROTECTED FOR RE-INSTALLATION.

EXISTING EQUIPMENT RACKS TO REMAIN UNTIL ALL RACK MOUNTED DEVICES RELOCATED TO NEW SC-ER-1.

NOTES:

1. REFER TO 5/B405-TN302 FOR LADDER RACK LAYOUT - TR-405-3-1.

2. REFER TO 7/B405-TN302 FOR CONNECTIVITY RISER DIAGRAM - TR-405-3-1.

3. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.

KEYNOTES:

1. REFER TO AE211 FOR PLYWOOD INFORMATION.

2. CONTRACTOR TO COORDINATE FINAL RACK LOCATION WITH OWNER PRIOR TO INSTALLATION.

3. CONTRACTOR TO COORDINATE FINAL LOCATION AND FIELD OF VIEW WITH OWNER PRIOR TO

INSTALLATION.

NOTES:

1. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.

KEYNOTES:

1. REMOVE EXISTING PATCH PANELS FROM 2-POST RACKS WITHOUT REMOVING HORIZONTAL CABLES. REMOVE

2- POST RACKS AND REPLACE THEM WITH SC-ER-1.

2. EXISTING NURSE CALL EQUIPMENT TO BE REMOVED FROM 2-POST RACK FOR INSTALLATION INTO SC-ER-1

WITHOUT REMOVING OR RE-CABLING EXISTING CABLES.

NOTES:

1. REFER TO 7/B405-TN302 FOR CONNECTIVITY RISER DIAGRAM - TR-405-3-1.

2. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.

KEYNOTES:

1. REINSTALL EXISTING PATCH PANELS ON SC-ER-1.

2. CONTRACTOR TO TEST AND CERTIFY ALL HORIZONTAL CABLING ON THIS PATCH

PANEL AFTER INSTALLATION ON SC-ER-1.

3. REINSTALL NURSE CALL SYSTEM IN SC-ER-1. TEST AND CERTIFY SYSTEM FOR

COMPLETE OPERATION.

4. UPS AND PDU’S PROVIDED AND INSTALLED BY THE E.C. REFER TO ELECTRICAL

DRAWINGS FOR MORE INFORMATION.

NOTES:

1. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.

2. INSTALL BASKET TRAY AT 7'-6" AFF.

3. REFER TO 2/B405-TN400 TECHNOLOGY CONDUIT RISER DIAGRAM.

4. REFER TO TN503 CONDUIT AND CABLE PATHWAY DIAGRAMS FOR ADDITIONAL

INFORMATION.

0 4' 8'2' 0 4' 8'2'

0 4' 8'2'

0 4' 8'2'

SC-GND-1

EXISTING

GROUND BAR

EXISTING

GROUND BAR

ELECTRICAL ENTRANCE

INTERSYSTEM BONDING

TERMINATION

GROUNDING ELECTRODE

CONDUCTOR BY OTHERS

ELECTRICAL GROUNDING

ELECTRODE SYSTEM

EXISTING TELECOMMUNICATIONS BONDING

BACKBONE (TBB) (TYP)

FIRST

FLOOR

SECOND

FLOOR

THIRD

FLOOR

EXISTING TR-405-1-1

EXISTING TR-405-2-1

EXISTING TR-405-3-1

NOTES:

1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES OF

MATERIALS. THIS RISER IS SHOWN FOR CLARIFICATION OF CONNECTION LOCATIONS AND

CONDUCTOR TYPE. ALL CONNECTIONS AND SYSTEM DEVICES SHOWN ARE TYPICAL AND NOT

REPRESENTATIVE OF ACTUAL PROJECT QUANTITIES. REFER TO FLOOR PLANS AND ENLARGED

FLOOR PLANS FOR ACTUAL QUANTITIES AND LOCATIONS OF DEVICES AND MORE SPECIFIC ROUTING

INFORMATION. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

2. ALL CONDUCTORS IN THE TECHNOLOGY BONDING SYSTEM SHALL BE MINIMUM SIZE OF 3/0 AWG

PLENUM RATED COPPER (GREEN OR MARKED WITH A DISTINCTIVE GREEN COLOR) UNLESS

CONDUCTOR LENGTH IS LESS THAN 66 FEET. REFER TO BONDING CONDUCTOR SIZING SCHEDULE

FOR SIZING CRITERIA FOR CONDUCTORS LESS THAN 66 FEET IN LENGTH. REFER TO

SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

3. ALL BONDING CONDUCTORS AND BONDING JUMPERS SHALL BE CONNECTED BY COMPRESSION

LUGS, EXOTHERMIC WELDING, OR IRREVERSIBLE COMPRESSION CONNECTORS. SOLDER IS NOT AN

ACCEPTABLE MEANS OF CONNECTION. SHEET METAL SCREWS SHALL NOT BE USED TO CONNECT

COMMUNICATIONS BONDING CONDUCTORS TO EQUIPMENT. WHERE NECESSARY, REMOVE PAINT

AND/OR USE PAINT-PIERCING WASHERS TO PROVIDE PROPER ELECTRICAL BOND AT ALL

CONNECTIONS.

4. REFER TO 2/TN400 FOR TYPICAL TELECOM ROOM BONDING FLOW DIAGRAM.

5. REFER TO TELECOM ROOM REFERENCES SCHEDULE ON DRAWING TN000 FOR

TELECOMMUNICATIONS ROOM NUMBER AND LOCATION INFORMATION.

KEYNOTES:

1. BONDING CONDUCTOR FOR TELECOMMUNICATIONS (BCT).

FIRST

FLOOR

SECOND

FLOOR

THIRD

FLOOR

TR-405-1-1

TR-405-2-1

TR-405-3-1

EXISTING 4" CONDUITS

EXISTING (4) 4" CONDUITS IN DUCT BANK

TO B404

EXISTING (2) 6" CONDUITS

IN TUNNEL TO B404

(2) 4" C

(2) 4" C

(2) 4" C

(2) 4" C

NOTES:

1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES OF

MATERIALS SHOWN. THIS RISER IS SHOWN FOR CLARIFICATION OF CONNECTION(S), LOCATIONS AND CABLE TYPE. ALL INFORMATION OUTLETS ARE TYPICAL OF THE OUTLETS IN THE AREA SHOWN.

REFER TO FLOOR PLANS FOR MORE SPECIFIC ROUTING INFORMATION. REFER TO SPECIFICATIONS

FOR ADDITIONAL REQUIREMENTS.

2. REFER TO TN600 FOR TECHNOLOGY EQUIPMENT SCHEDULE.

3. REFER TO TN503 CONDUIT AND CABLE PATHWAY DIAGRAMS FOR ADDITIONAL INFORMATION.

SC-BET

EXISTING 6" CONDUITS

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :

B

IM

/2

V

A T o m a h

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-7

.B

.E

T

R

.r v t

/8

/2

:0

:0

P

M

B405-TN400

TELECOMMUNICATIONS DETAILS EHRM INFRASTRUCTURE

UPGRADES, TOMAH, WI

TOMAH, WI

676-21-700

B405

02/11/2022 PDN JFK

16477

225 W WASHINGTON STREET

SUITE 2700 CHICAGO, IL 60606

312.294.0501 FAX: 312.294.0003

www.imegcorp.com # 21003227.00

NO SCALE

TECHNOLOGY BONDING RISER DIAGRAM

NO SCALE

TECHNOLOGY CONDUIT RISER DIAGRAM

Revisions: Date:

INDIVIDUAL CAMERA REQUIREMENTS SCHEDULE

CAMERA #

CAMERA

TYPE FIELD OF VIEW DESCRIPTION

DETAIL

REFERENCE NOTES

01-01 CM-1 GENERAL VIEW OF

TELECOMMUNICATION ROOM

6/TN400

02-01 CM-1 GENERAL VIEW OF

TELECOMMUNICATION ROOM

6/TN400

03-01 CM-1 GENERAL VIEW OF

TELECOMMUNICATION ROOM

6/TN400

6C13

1615A

1615C

6C17

1646B

16481 A

1647 1649 1658 1675

1640A 1640 1640B 1646 S22 1672

1615B

S24

406E8A

C

1647A

1653 1654

406E8

1617A

1631A

2D 4D

1D-WAP

D

3D

3D3D

1D-WAP

D

1D-WAP

1V2D

1D-WAP 6

D

D 6

D

1V 2V

V

D

4D

D

4D

D

4D

D

1D-CAM

1D-WAP

D 6

D

3D

V

1D-CAM

1D-CAM

3D 1V

1D-WAP

D

1D-WAP

D

V

D

D

4V

3D3D1D-WAP

3D 3D 4V

4V

D

1D1V

D

D

1D-WAP

1D-GWAP

4D

D

3D 1D-WAP

D

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-CAM

D

4D

EXISTING TR-406-1-1

B406-TN300

B406-TN300

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :

B

IM

/2

V

A T o m a h

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-7

.B

.E

T

R

.r v t

/8

/2

:0

:3

P

M

B406-TD101

FIRST FLOOR DEMOLITION -

TELECOMMUNICATIONS

EHRM INFRASTRUCTURE

UPGRADES, TOMAH, WI

TOMAH, WI

676-700

B406

02/11/2022 PDN JFK

16477

225 W WASHINGTON STREET

SUITE 2700 CHICAGO, IL 60606

312.294.0501 FAX: 312.294.0003

www.imegcorp.com # 21003227.00

TECHNOLOGY SHEET NOTES:

1. REFER TO TN000 TECHNOLOGY COVERSHEET

FOR TECHNOLOGY SYMBOL LIST.

2. ALL INFORMATION OUTLETS ON THIS SHEET

SERVED FROM EXISTING TR-406-1-1

3. ALL EXISTING INFORMATION OUTLETS,

CONDUITS AND BACKBOXES TO REMAIN.

EXISTING CABLING TO BE REMOVED FROM

END TO END AND REPLACED WITH NEW DATA

CABLES. REFER TO B406-TN101 FOR MORE

INFORMATION.

N O R

HT

1/8" = 1'-0"

FIRST FLOOR DEMOLITION - TELECOMMUNICATIONS

KEYNOTES:

1. EXISTING BACKBONE AND HORIZONTAL

COPPER AND FIBER TO BE COMPLETELY

REMOVED FROM END TO END AFTER

COMPLETION OF ALL NEW CABLING.

2. EXISTING ANALOG HORIZONTAL AND RISER

CABLING TO BE COMPLETELY REMOVED

AFTER ALL ACTIVE PORTS HAVE BEEN

ABANDONED. COORDINATE REMOVAL WITH

OWNER.

DN. 20-R.

2607 2608

S24

6C21

6C23

2629A

2633A

6C25

2634A

2603A

2604A

6C22

26202621

2632 2640 2646 2648 S22 2674

2631 2633 2645 2649

6C28

2659A

2658A

6C29

6C27

2644A

V

2D 3D

1V

D

D

V

D

D

V

V

1D-WAP

1D-GWAP

1D-WAP

3D 2D

V

1V

D

D

D

V

D

V

1V2D3D

D

D

1D-WAP

1V2D3D

1V 2D

D

1D-WAP

D

2D1V

1V 2D

D 1 V

D

2D1V 2D 1V

D

D

2D 1V

1V2D

D

D

2D 1V

2D

D

D

D

1D-WAP

V

D

D

2D

D

4D

D

D

1D-CAM

1D-WAP

1D-WAP

3D3D

D

V

D

D

1D-WAP

D

D

1V2D

D

1V2D

1D-WAP

3D

V

V

V

V

V

V

V

3D

V

V

D

2D1V

1D-WAP

D

D

1V 3D

D 3D

1V

2V

3D

1D-WAP

1V 1V

3D 2D 2D3D2D

D

V

V

3D 4V 2D

V

V

3D3D

D

D1D-WAP

D

5D

D

V

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

W

P

1D-CAM

1D-CAM

1D-CAM

D

EXISTING HILL ROM ROOM

EXISTING WALL FIELD

EXISTING TR-406-2-1

B406-TN301

B406-TN301

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :

B

IM

/2

V

A T o m a h

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-7

.B

.E

T

R

.r v t

/8

/2

:0

:3

P

M

B406-TD102

SECOND FLOOR DEMOLITION -

TELECOMMUNICATIONS

EHRM INFRASTRUCTURE

UPGRADES, TOMAH, WI

TOMAH, WI

676-700

B406

02/11/2022 PDN JFK

16477

225 W WASHINGTON STREET

SUITE 2700 CHICAGO, IL 60606

312.294.0501 FAX: 312.294.0003

www.imegcorp.com # 21003227.00

N O R

HT

1/8" = 1'-0"

SECOND FLOOR DEMOLITION - TELECOMMUNICATIONS

TECHNOLOGY SHEET NOTES:

1. REFER TO TN000 TECHNOLOGY COVERSHEET

FOR TECHNOLOGY SYMBOL LIST.

2. ALL INFORMATION OUTLETS ON THIS SHEET

SERVED FROM EXISTING TR-406-2-1.

3. ALL EXISTING INFORMATION OUTLETS,

CONDUITS AND BACKBOXES TO REMAIN.

EXISTING CABLING TO BE REMOVED FROM

END TO END AND REPLACED WITH NEW DATA

CABLES. REFER TO B406-TN102 FOR MORE

INFORMATION.

KEYNOTES:

1. EXISTING BACKBONE AND HORIZONTAL

COPPER AND FIBER TO BE COMPLETELY

REMOVED FROM END TO END AFTER

COMPLETION OF ALL NEW CABLING.

2. EXISTING ANALOG HORIZONTAL AND RISER

CABLING TO BE COMPLETELY REMOVED

AFTER ALL ACTIVE PORTS HAVE BEEN

ABANDONED. COORDINATE REMOVAL WITH

OWNER.

3644A

DN. 20-R.

UP 13-R.

DN. 20-R.

6C31

3601 36023600

3604A

3603A

6C32 S24 3632 3636 3638

3640 3642

36503650B 3650A

3654 3656 3658 S22 3678

6C38

3663A

3668A

3683 3684

6C37

6C39

3631 3633 3635 3637

3635A

6C33

3623 3622

3650C

1D-CAM

D

2D3D

1D

D

D

1D

D

D

1D-GWAP

D

D

1D

D

D

1D

1D

5D

4D

1D

D

D

1D-GWAP

D

D

1D

1D

D

D

D

D

1D

1D-WAP

1D-WAP

D

D

1D

D

D

1D

1D-CAM

1V

D

D

D

D

6D

1D-WAP

D

D

1D-GWAP

4D

1D-CAM

D

1D-CAM

1D-WAP

D

3D 3D

1D-WAP

1D

4D

D

D

D

D

2D3D

D

1D

D

D

1D-GWAP

1D 2 D

D

1D

D

D

3D

1D-CAM

D

-C A

M

D

3D

3D2D

1D

1D

D

D

1D-GWAP

D

3D

D

D

1D

D

D

1D

D

D

1D

D

D

D

D

D

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

W P

WP

W

P

1D-CAM

1D-CAM

1D-CAM

4D

4D2D

EXISTING HILL ROM ROOM

EXISTING WALL FIELD

EXISTING TR-406-3-1

B406-TN302

B406-TN302

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :

B

IM

/2

V

A T o m a h

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-7

.B

.E

T

R

.r v t

/8

/2

:0

:3

P

M

B406-TD103

THIRD FLOOR DEMOLITION -

TELECOMMUNICATIONS

EHRM INFRASTRUCTURE

UPGRADES, TOMAH, WI

TOMAH, WI

676-700

B406

02/11/2022 PDN JFK

16477

225 W WASHINGTON STREET

SUITE 2700 CHICAGO, IL 60606

312.294.0501 FAX: 312.294.0003

www.imegcorp.com # 21003227.00

N O R

HT

1/8" = 1'-0"

THIRD FLOOR DEMOLITION - TELECOMMUNICATIONS

TECHNOLOGY SHEET NOTES:

1. REFER TO TN000 TECHNOLOGY COVERSHEET

FOR TECHNOLOGY SYMBOL LIST.

2. ALL INFORMATION OUTLETS ON THIS SHEET

SERVED FROM EXISTING TR-406-3-1.

3. ALL EXISTING INFORMATION OUTLETS,

CONDUITS AND BACKBOXES TO REMAIN.

EXISTING CABLING TO BE REMOVED FROM

END TO END AND REPLACED WITH NEW DATA

CABLES. REFER TO B406-TN103 FOR MORE

INFORMATION.

KEYNOTES:

1. EXISTING BACKBONE AND HORIZONTAL

COPPER AND FIBER TO BE COMPLETELY

REMOVED FROM END TO END AFTER

COMPLETION OF ALL NEW CABLING.

2. EXISTING ANALOG HORIZONTAL AND RISER

CABLING TO BE COMPLETELY REMOVED

AFTER ALL ACTIVE PORTS HAVE BEEN

ABANDONED. COORDINATE REMOVAL WITH

OWNER.

BASEMENT

BA100

F.D.

F L A S H

T A N K

UP

(1) 4" FOR A LEG

FROM/TO BUILDING 401

(1) 4" FOR B LEG

(1) 4" FOR A LEG

(1) 4" FOR B LEG

(1) 4" FOR COPPER

FROM/TO BUILDING 455

JUNCTION BOX (TYP.)

4" C TO TR-406-1-1

PULLBOX (TYP.)

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :

B

IM

/2

V

A T o m a h

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-7

.B

.E

T

R

.r v t

/8

/2

:0

:3

P

M

B406-TN100

BASEMENT FLOOR PLAN -

TELECOMMUNICATIONS

EHRM INFRASTRUCTURE

UPGRADES, TOMAH, WI

TOMAH, WI

676-700

B406

02/11/2022 PDN JFK

16477

225 W WASHINGTON STREET

SUITE 2700 CHICAGO, IL 60606

312.294.0501 FAX: 312.294.0003

www.imegcorp.com # 21003227.00

N O R

HT

1/8" = 1'-0"

BASEMENT FLOOR PLAN - TELECOMMUNICATIONS

TECHNOLOGY SHEET NOTES:

1. REFER TO TN000 TECHNOLOGY COVERSHEET

FOR TECHNOLOGY GENERAL NOTES,

TECHNOLOGY INSTALLATION NOTES AND

SYMBOL LIST.

2. REFER TO TN600 FOR GENERAL TECHNOLOGY

EQUIPMENT SCHEDULE.

3. CONTRACTOR TO COORDINATE PULL BOX

LOCATIONS AS REQUIRED.

4. CONTRACTOR TO FIELD VERIFY CONDUIT

RISER ROUTE WITH OWNER PRIOR TO

INSTALLATION.

KEYNOTES:

1. CONTRACTOR TO PROVIDE PULL BOX SIZED

PER CABLING AND CODE REQUIREMENTS.

6C13

1615A

1615C

6C17

1646B

16481 A

1647 1649 1658 1675

1640A 1640 1640B 1646 S22 1672

1615B

S24

406E8A

C

1647A

1653 1654

406E8

1617A

1631A

1D-GWAP

2D 4D

1D-WAP

D

3D

3D3D

1D-WAP

D

1D-WAP

1D2D

1D-WAP 6

D

D 6

D

1D 2D

D

D

4D

D

4D

D

4D

D

1D-CAM

1D-WAP

D 6

D

3D

D

1D-CAM

1D-CAM

3D 1D

1D-WAP

D

1D-WAP

D

D

D

D

4D

3D3D1D-WAP

3D 3D 4D

4D

D

2D

D

D

1D-WAP

4D

D

3D 1D-WAP

D

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

W

P

CSS

1D-CAM

D

4D

1D-CAM

B406-TN300

B406-TN300

TR-406-1-1

EXISTING TR-406-1-1

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :

B

IM

/2

V

A T o m a h

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-7

.B

.E

T

R

.r v t

/8

/2

:0

:3

P

M

B406-TN101

FIRST FLOOR -

TELECOMMUNICATIONS

EHRM INFRASTRUCTURE

UPGRADES, TOMAH, WI

TOMAH, WI

676-700

B406

02/11/2022 PDN JFK

16477

225 W WASHINGTON STREET

SUITE 2700 CHICAGO, IL 60606

312.294.0501 FAX: 312.294.0003

www.imegcorp.com # 21003227.00

N O R

HT

1/8" = 1'-0"

FIRST FLOOR - TELECOMMUNICATIONS

TECHNOLOGY SHEET NOTES:

1. REFER TO TN000 TECHNOLOGY COVERSHEET

FOR TECHNOLOGY GENERAL NOTES,

TECHNOLOGY INSTALLATION NOTES AND

SYMBOL LIST.

2. ALL INFORMATION OUTLETS ON THIS SHEET

SHALL BE SERVED FROM TR-406-1-1.

3. REFER TO TN600 FOR GENERAL TECHNOLOGY

EQUIPMENT SCHEDULE.

4. CONTRACTOR TO INCLUDE AN ALLOWANCE

FOR 10 ADDITIONAL 2-PORTS CAT 6A

INFORMATION OUTLETS IN THEIR PROPOSAL

FOR THIS SHEET. FUTURE INFORMATION

OUTLET LOCATIONS WILL BE DETERMINED BY

THE VA AT A LATER DATE.

5. CONTRACTOR TO FIELD VERIFY CONDUIT

RISER ROUTE WITH OWNER PRIOR TO

INSTALLATION.

6. ALL INFORMATION OUTLETS ON THIS SHEET

TO BE CABLED ON A SCHEDULED BASIS WITH

OWNER WHILE OCCUPIED WITH STAFF AND

PATIENTS. COORDINATE DEMO AND CABLE

REPLACEMENT WITH OWNER. REFER TO

SHEET B406-TD101 FOR MORE INFORMATION.

7. CONTRACTOR TO PROVIDE NEW J-HOOK

ROUTES FOR ALL NEW CABLING. J-HOOK SIZE

AND QUANTITY TO BE PER MANUFACTURER

RECOMMENDATIONS.

0 8' 16'4'

Revisions: Date:

KEYNOTES:

1. EXISTING ANALOG HORIZONTAL AND RISER

CABLING TO BE COMPLETELY REMOVED

AFTER ALL ACTIVE PORTS HAVE BEEN

ABANDONED. COORDINATE REMOVAL WITH

OWNER.

DN. 20-R.

2607 2608

S24

6C21

6C23

2629A

2633A

6C25

2634A

2603A

2604A

6C22

26202621

2632 2640 2646 2648 S22 2674

2631 2633 2645 2649

6C28

2659A

2658A

6C29

6C27

2644A

1D-GWAP

D

2D 3D

1D

D

D

D

D

D

D

D

1D-WAP

1D-WAP

3D 2D

D

1D

D

D

D

D

D

D

1D2D3D

D

D

1D-WAP

1D2D3D

1D 2D

D

1D-WAP

D

2D1D

1D 2D

D 1 D

D

2D1D 2D 1D

D

D

2D 1D

1D2D

D

D

2D 1D

2D

D

D

D

1D-WAP

D

D

D

2D

D

4D

D

D

1D-CAM

1D-WAP

1D-WAP

3D3D

D

D

D

D

1D-WAP

D

D

1D2D

D

1D2D

1D-WAP

3D

D

D

D

D

D

D

D

3D

D

D

D

2D1D

1D-WAP

D

D

1D 3D

D 3D

1D

2D

3D

1D-WAP

1D 1D

3D 2D 2D3D2D

D

3D 4D 2D

D

D

3D3D

D

D1D-WAP

D

5D

D

D

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

CSS

W

P

1D-CAM

D

1D-CAM

B406-TN301

B406-TN301

TR-406-2-1

EXISTING HILL ROM ROOM EXISTING WALL FIELD

EXISTING TR-406-2-1

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :

B

IM

/2

V

A T o m a h

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-7

.B

.E

T

R

.r v t

/8

/2

:0

:3

P

M

B406-TN102

SECOND FLOOR -

TELECOMMUNICATIONS

EHRM INFRASTRUCTURE

UPGRADES, TOMAH, WI

TOMAH, WI

676-700

B406

02/11/2022 PDN JFK

16477

225 W WASHINGTON STREET

SUITE 2700 CHICAGO, IL 60606

312.294.0501 FAX: 312.294.0003

www.imegcorp.com # 21003227.00

N O R

HT

1/8" = 1'-0"

SECOND FLOOR - TELECOMMUNICATIONS

TECHNOLOGY SHEET NOTES:

1. REFER TO TN000 TECHNOLOGY COVERSHEET

FOR TECHNOLOGY GENERAL NOTES,

TECHNOLOGY INSTALLATION NOTES AND

SYMBOL LIST.

2. ALL INFORMATION OUTLETS ON THIS SHEET

SHALL BE SERVED FROM TR-406-2-1.

3. REFER TO TN600 FOR GENERAL TECHNOLOGY

EQUIPMENT SCHEDULE.

4. CONTRACTOR TO INCLUDE AN ALLOWANCE

FOR 10 ADDITIONAL 2-PORTS CAT 6A

INFORMATION OUTLETS IN THEIR PROPOSAL

FOR THIS SHEET. FUTURE INFORMATION

OUTLET LOCATIONS WILL BE DETERMINED BY

THE VA AT A LATER DATE.

5. CONTRACTOR TO FIELD VERIFY CONDUIT

RISER ROUTE WITH OWNER PRIOR TO

INSTALLATION.

6. ALL INFORMATION OUTLETS ON THIS SHEET

TO BE CABLED ON A SCHEDULED BASIS WITH

OWNER WHILE OCCUPIED WITH STAFF AND

PATIENTS. COORDINATE DEMO AND CABLE

REPLACEMENT WITH OWNER. REFER TO

SHEET B406-TD102 FOR MORE INFORMATION.

7. CONTRACTOR TO PROVIDE NEW J-HOOK

ROUTES FOR ALL NEW CABLING. J-HOOK SIZE

AND QUANTITY TO BE PER MANUFACTURER

RECOMMENDATIONS.

0 8' 16'4'

Revisions: Date:

KEYNOTES:

1. EXISTING ANALOG HORIZONTAL AND RISER

CABLING TO BE COMPLETELY REMOVED

AFTER ALL ACTIVE PORTS HAVE BEEN

ABANDONED. COORDINATE REMOVAL WITH

3644A

DN. 20-R.

UP 13-R.

DN. 20-R.

6C31

3601 36023600

3604A

3603A

6C32 S24 3632 3636 3638

3640 3642

36503650B 3650A

3654 3656 3658 S22 3678

6C38

3663A

3668A

3683 3684

6C37

6C39

3631 3633 3635 3637

3635A

6C33

3623 3622

3650C

1D-GWAP

1D-GWAP

1D-GWAP

1D-GWAP

1D-GWAP

1D-CAM

D

2D3D

1D

D

D

1D

D

D

D

D

1D

D

D

1D

1D

5D

4D

1D

D

D

D

D

1D

1D

D

D

D

D

1D

1D-WAP

1D-WAP

D

D

1D

D

D

1D

1D-CAM

1D

D

D

D

D

6D

1D-WAP

D

D

4D

1D-CAM

D

1D-CAM

1D-WAP

D

3D 3D

1D-WAP

D

D

D

D

2D3D

D

1D

D

D

1D 2 D

D

1D

D

D

3D

1D-CAM

D

-C A

M

D

3D

3D2D

1D

1D

D

D

D

3D

D

D

1D

D

D

1D

D

D

1D

D

D

D

D

D

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

W

P

CSS

1D-CAM

4D2D

1D-CAM

B406-TN302

B406-TN302

TR-406-3-1

EXISTING HILL ROM ROOM

EXISTING WALL FIELD

EXISTING TR-406-3-1

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :

B

IM

/2

V

A T o m a h

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-7

.B

.E

T

R

.r v t

/8

/2

:0

:3

P

M

B406-TN103

THIRD FLOOR -

TELECOMMUNICATIONS

EHRM INFRASTRUCTURE

UPGRADES, TOMAH, WI

TOMAH, WI

676-700

B406

02/11/2022 PDN JFK

16477

225 W WASHINGTON STREET

SUITE 2700 CHICAGO, IL 60606

312.294.0501 FAX: 312.294.0003

www.imegcorp.com # 21003227.00

N O R

HT

1/8" = 1'-0"

THIRD FLOOR - TELECOMMUNICATIONS

TECHNOLOGY SHEET NOTES:

1. REFER TO TN000 TECHNOLOGY COVERSHEET

FOR TECHNOLOGY GENERAL NOTES,

TECHNOLOGY INSTALLATION NOTES AND

SYMBOL LIST.

2. ALL INFORMATION OUTLETS ON THIS SHEET

SHALL BE SERVED FROM TR-406-3-1.

3. REFER TO TN600 FOR GENERAL TECHNOLOGY

EQUIPMENT SCHEDULE.

4. CONTRACTOR TO INCLUDE AN ALLOWANCE

FOR 10 ADDITIONAL 2-PORTS CAT 6A

INFORMATION OUTLETS IN THEIR PROPOSAL

FOR THIS SHEET. FUTURE INFORMATION

OUTLET LOCATIONS WILL BE DETERMINED BY

THE VA AT A LATER DATE.

5. CONTRACTOR TO FIELD VERIFY CONDUIT

RISER ROUTE WITH OWNER PRIOR TO

INSTALLATION.

6. ALL INFORMATION OUTLETS ON THIS SHEET

TO BE CABLED ON A SCHEDULED BASIS WITH

OWNER WHILE OCCUPIED WITH STAFF AND

PATIENTS. COORDINATE DEMO AND CABLE

REPLACEMENT WITH OWNER. REFER TO

SHEET B406-TD103 FOR MORE INFORMATION.

7. CONTRACTOR TO PROVIDE NEW J-HOOK

ROUTES FOR ALL NEW CABLING. J-HOOK SIZE

AND QUANTITY TO BE PER MANUFACTURER

RECOMMENDATIONS.

0 8' 16'4'

Revisions: Date:

KEYNOTES:

1. EXISTING ANALOG HORIZONTAL AND RISER

CABLING TO BE COMPLETELY REMOVED

AFTER ALL ACTIVE PORTS HAVE BEEN

ABANDONED. COORDINATE REMOVAL WITH

PTZ

CCTV

SC-MPP-2

OWNER

PROVIDED

NETWORK

EQUIPMENT

SC-MPP-2

SC-FDC-1 SC-MPP-1

SC-BET

SC-FDC-1

SC-MPP-1

SC-FDC-1

SC-GND-1

SC-VWM-1

SC-ER-1 (TYP.)

B406-TN300

(TYP.)

CM-1

01-01

SC-CT-2

(TYP.)

PW-CPW-1

(2) 4" C FROM BASEMENT

(2) 4" C FROM BASEMENT

18"x6"

18"x6"

"x

"x

18"x6"

SC-BET

(TYPICAL OF 5)

SC-ER-1

(TYP.)

SC-FDC-1

SC-MPP-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-HWM-1

SC-HWM-2

SC-HWM-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-FDC-1

SC-BLK-1

SC-MPP-2

SC-MPP-2

SC-MPP-2

SC-MPP-2

SC-MPP-2

SC-MPP-2

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-HWM-1

SC-HWM-2

SC-HWM-2

SC-HWM-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

NETWORK SWITCH

NETWORK SWITCH

NETWORK SWITCH

NETWORK SWITCH

NETWORK SWITCH

(TYP.)

SC-VWM-1

PDU

UPS UPS

3 3

24 STRAND SM FIBER FROM

BUILDING 32 (LEG A)

(10) CAT 5E 25-PAIRS COPPER

CABLES FROM BUILDING 32

NOTES:

1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES OF MATERIALS SHOWN.

THIS RISER IS SHOWN FOR CLARIFICATION OF CONNECTION(S), LOCATIONS AND CABLE TYPE. ALL INFORMATION OUTLETS ARE TYPICAL OF THE OUTLETS IN THE AREA SHOWN. REFER TO FLOOR PLANS FOR MORE SPECIFIC ROUTING INFORMATION. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

2. REFER TO TN600 FOR TECHNOLOGY EQUIPMENT SCHEDULE.

KEYNOTES:

1. #D INDICATES VOICE/DATA FACEPLATE CONFIGURATION. REFER TO INFORMATION OUTLET SCHEDULE ON

TN600 FOR ADDITIONAL INFORMATION. REFER TO TECHNOLOGY FLOOR PLANS AND TECHNOLOGY

EQUIPMENT SCHEDULE FOR ADDITIONAL INFORMATION.

2. FIBER OPTIC PATCH CORDS. REFER TO SPECIFICATIONS.

3. 24 GAUGE, CAT 6A UTP CABLE. REFER TO SPECIFICATIONS.

4. RJ-45 TO RJ-45 CATEGORY 6A UTP PATCH CORDS. REFER TO SPECIFICATIONS FOR PATCH CORD

REQUIREMENTS.

5. CONTRACTOR SHALL TERMINATE 1 PAIR PER PORT, USING PINS 4 AND 5.

6. PROVIDE CAT 6A CABLE FOR CAMERA. TERMINATE CAT 6A CABLE WITH RJ-45 PLUG.

7. LIGHTNING PROTECTION. REFER TO 6/B406-TN300 FOR LOCATION.

8. (2) CAT 5E 25-PAIR CABLES FROM LIGHTNING PROTECTION.

#D-WAP

#D

#D-CAM

24 STRAND SM FIBER FROM

BUILDING 32 (LEG B)

TR-406-1-1

24 CAT 6A CABLES TO EXISTING TR-406-1-1

REFER TO B406-TD101 FOR EXACT LOCATION

PTZ

CCTV

CM-1

24 STRAND SM FIBER TO EXISTING TR-406-1-1

REFER TO B406-TD101 FOR EXACT LOCATION

B -T

N

EXISTING EQUIPMENT

RACK 1

EXISTING LADDER RACK

(TYP.)

SC-MPP-1

EXISTING EQUIPMENT RACK

SC-FDC-1

(24) CAT 6A CABLES FROM

TR-406-1-1

NOTES:

1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES OF MATERIALS SHOWN. THIS RISER IS SHOWN FOR CLARIFICATION OF CONNECTION(S), LOCATIONS AND CABLE TYPE. ALL INFORMATION OUTLETS ARE TYPICAL OF THE OUTLETS IN THE AREA SHOWN. REFER TO FLOOR PLANS FOR MORE SPECIFIC ROUTING INFORMATION. REFER TO SPECIFICATIONS FOR

ADDITIONAL REQUIREMENTS.

2. REFER TO TN600 FOR TECHNOLOGY EQUIPMENT SCHEDULE.

KEYNOTES:

1. CONTRACTOR TO PROVIDE (2) FIBER OPTIC PATCH CORDS FOR CONNECTIVITY TO OWNER EQUIPMENT.

2. CONTRACTOR TO PROVIDE (6) CAT 6A PATCH CORDS FOR CONNECTIVITY TO OWNER EQUIPMENT.

EXISTING TR-406-1-1

TO OWNER PROVIDED

EQUIPMENT 2

24 STRAND SM FIBER FROM

TR-406-1-1

TO OWNER PROVIDED

EQUIPMENT 1

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com SES Project :

B

IM

/2

V

A T o m a h

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-7

.B

.E

T

R

.r v t

/8

/2

:0

:4

P

M

B406-TN300

TELECOMMUNICATIONS ROOM

ENLARGEMENTS

EHRM INFRASTRUCTURE

UPGRADES, TOMAH, WI

TOMAH, WI

676-700

B406

02/11/2022 PDN JFK

16477

225 W WASHINGTON STREET

SUITE 2700 CHICAGO, IL 60606

312.294.0501 FAX: 312.294.0003

www.imegcorp.com # 21003227.00

N O R

HT

1/4" = 1'-0"

DATA ROOM ENLARGEMENT - TR-406-1-1

N O R

HT

1/4" = 1'-0"

LADDER RACK LAYOUT - TR-406-1-1

1" = 1'-0"

DATA RACK ELEVATION - TR-406-1-1

NOTES:

1. REFER TO 6/B406-TN300 FOR LADDER RACK LAYOUT - TR-406-1-1.

2. REFER TO 8/B406-TN300 FOR CONNECTIVITY RISER DIAGRAM - TR-406-1-1.

3. REFER TO AE211 FOR PLYWOOD INFORMATION.

4. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.

KEYNOTES:

1. REFER TO 1/TN400 BONDING BUS BAR DETAIL FOR ADDITIONAL INFORMATION.

2. CONTRACTOR TO COORDINATE FINAL RACK LOCATION WITH OWNER PRIOR TO INSTALLATION.

3. CONTRACTOR TO COORDINATE FINAL LOCATION AND FIELD OF VIEW WITH OWNER PRIOR TO

INSTALLATION.

NOTES:

1. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.

2. INSTALL BASEKET TRAY AT 7'-6" AFF.

3. REFER TO 2/B406-TN400 TECHNOLOGY CONDUIT RISER DIAGRAM FOR ADDITIONAL INFORMATION.

4. REFER TO TN503 CONDUIT AND CABLE PATHWAY DIAGRAMS FOR ADDITIONAL INFORMATION.

KEYNOTES:

1. CONTRACTOR TO COORDINATE FINAL LOCATION FOR LIGHTNING PROTECTION ENCLOSURE WITH

OWNER PRIOR TO INSTALLATION.

NOTES:

1. REFER TO 8/B406-TN300 FOR CONNECTIVITY RISER DIAGRAM - TR-406-1-1.

2. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.

KEYNOTES:

1. DEDICATED FIBER PANEL FOR 24 STRAND SM FIBER TO EXISTING TR-406-1-1.

2. DEDICATED PATCH PANEL FOR 24 CAT 6A CABLES TO EXISTING TR-406-1-1.

3. UPS AND PDU’S PROVIDED AND INSTALLED BY THE E.C. REFER TO ELECTRICAL

DRAWINGS FOR MORE INFORMATION.

NO SCALE

CONNECTIVITY RISER DIAGRAM - TR-406-1-1

N O R

HT

1/4" = 1'-0"

DATA ROOM ENLARGEMENT - EXISTING TR-406-1-1

N O R

HT

1/4" = 1'-0"

LADDER RACK LAYOUT - EXISTING TR-406-1-1

1" = 1'-0"

DATA RACK ELEVATION - EXISTING TR-406-1-1

NOTES:

1. REFER TO 4/B406-TN300 FOR CONNECTIVITY RISER DIAGRAM - EXISTING TR-406-1-1.

2. REFER TO TN600 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.

KEYNOTES:

1. CONTRACTOR TO REMOVE EXISTING RACK MOUNTED DEVICES AND RETURN TO OWNER.

NO SCALE

CONNECTIVITY RISER DIAGRAM - EXISTING TR-406-1-1

NOTES:

1. REFER TO 2/B406-TN300 FOR LADDER RACK LAYOUT - EXISTING TR-406-1-1.

2. REFER TO 4/B406-TN300 FOR CONNECTIVITY RISER DIAGRAM -EXISTING TR-406-1-1.

0 4' 8'2'

0 4' 8'2'

0 4' 8'2'

0 4' 8'2'

SC-MPP-2

OWNER

PROVIDED

NETWORK

EQUIPMENT

SC-MPP-2

SC-FDC-1 SC-MPP-1

SC-BET

SC-FDC-1

SC-MPP-1

SC-FDC-1

SC-GND-1

SC-VWM-1

SC-ER-1

(TYP.)

B406-TN301

(TYP.) 1

CM-1

02-01

SC-CT-2

(TYP.)

PW-CPW-1

(2) 4" C FROM FIRST FLOOR

(2) 4" C FROM FIRST FLOOR

18"x6"

"x

18"x6"

"x

18"x6"

SC-VWM-1 SC-ER-1

(TYP.)

SC-FDC-1

SC-BLK-1

SC-FDC-1

SC-BLK-1

SC-MPP-2

SC-MPP-2

SC-MPP-2

SC-MPP-2

SC-MPP-2

SC-MPP-2

SC-MPP-2

SC-MPP-1

SC-MPP-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-HWM-1 SC-HWM-1

SC-HWM-2 SC-HWM-2

SC-HWM-2

SC-HWM-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-HWM-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

(TYP.)

NETWORK SWITCH

NETWORK SWITCH

NETWORK SWITCH

NETWORK SWITCH

NETWORK SWITCH

PDU

UPS UPS

3 3

24 STRAND SM FIBER FROM

BUILDING 32 (LEG A)

(10) CAT 5E 25-PAIRS COPPER

CABLES FROM BUILDING 32

NOTES:

1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES OF MATERIALS SHOWN.

THIS RISER IS SHOWN FOR CLARIFICATION OF CONNECTION(S), LOCATIONS AND CABLE TYPE. ALL INFORMATION OUTLETS ARE TYPICAL OF THE OUTLETS IN THE AREA SHOWN. REFER TO FLOOR PLANS FOR MORE SPECIFIC ROUTING INFORMATION. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

2. REFER TO TN600 FOR TECHNOLOGY EQUIPMENT SCHEDULE.

KEYNOTES:

1. #D INDICATES VOICE/DATA FACEPLATE CONFIGURATION. REFER TO INFORMATION OUTLET SCHEDULE ON

TN600 FOR ADDITIONAL INFORMATION. REFER TO TECHNOLOGY FLOOR PLANS AND TECHNOLOGY

EQUIPMENT SCHEDULE FOR ADDITIONAL INFORMATION.

2. FIBER OPTIC PATCH CORDS. REFER TO SPECIFICATIONS.

3. 24 GAUGE, CAT 6A UTP CABLE. REFER TO SPECIFICATIONS.

4. RJ-45 TO RJ-45 CATEGORY 6A UTP PATCH CORDS. REFER TO SPECIFICATIONS FOR PATCH CORD

REQUIREMENTS.

5. CONTRACTOR SHALL TERMINATE 1 PAIR PER PORT, USING PINS 4 AND 5.

6. PROVIDE CAT 6A CABLE FOR CAMERA. TERMINATE CAT 6A CABLE WITH RJ-45 PLUG.

7. LIGHTNING PROTECTION. REFER TO 6/B406-TN300 FOR LOCATION.

8. (4) CAT 5E 25-PAIR CABLES FROM LIGHTNING PROTECTION.

#D-WAP

#D

#D-CAM

24 STRAND SM FIBER FROM

BUILDING 32 (LEG B)

24 CAT 6A CABLES TO EXISTING TR-406-2-1

REFER TO B406-TD102 FOR EXACT LOCATION

24 CAT 6A CABLES TO SECOND FLOOR EXISTING HILL

ROM ROOM. REFER TO B406-TD102 FOR EXACT

LOCATION

TR-406-1-1

PTZ

CCTV

CM-1

TR-406-2-1

24 STRAND SM FIBER TO EXISTING TR-406-2-1

REFER TO B406-TD102 FOR EXACT LOCATION

B -T

N

EXISTING EQUIPMENT

RACK

EXISTING LADDER RACK (TYP.)

EXISTING EQUIPMENT RACK

SC-FDC-1

SC-MPP-1

(24) CAT 6A CABLES FROM

TR-406-2-1

NOTES:

1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES OF MATERIALS SHOWN.

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .