Asbestos Report - AC-916579_HWY-287.pdf

PDF 4 MB Posted

Attached to
Landslide Repairs in Morovis, Puerto Rico
Solicitation number
693C73-24-B-000015
Issued by

About this file

This document is an Environmental Investigation Report for Asbestos Containing Building Materials (ACBM) related to a federal contract opportunity for Landslide Repairs in Morovis, Puerto Rico.

The report details a visual inspection and assessment conducted by CMC Environmental Corp at PR-159 Km 3.2 in Morovis, Puerto Rico as part of the Landslide and Road Damage Evaluation and Repairs project. The inspection found no asbestos containing materials present at the site. The report certifies that no further action is required regarding asbestos.

The related federal contract opportunity is for Landslide Repairs in Morovis, Puerto Rico, Solicitation Number 693C73-24-B-000015, issued by the Department of Transportation Federal Highway Administration. The project consists of repairing landslides and washouts on PR-155 and PR-159, including embankment reconstruction, wall construction, drainage installation, paving, and other work. The project is expected to cost between $10,000,000 to $15,000,000 and is set aside for certified Small Business Concerns. Bid documents will be issued on or about July 23, 2024, with bids due by the date specified in the solicitation.

View the file

Other files

File Type Posted
Results of Bid Opening - PR ER DOT PRMNT RPR(17).pdf PDF
Amendment 0004 - PR ER DOT PRMNT RPR(17).pdf PDF
Amendment 0003 - PR ER DOT PRMNT RPR(17).pdf PDF
Amendment 0002 Plans - AC-857579_HWY-258 260 261 262 263 265 - Part 4 of 4.pdf PDF
Amendment 0002 Plans - AC-857579_HWY-258 260 261 262 263 265 - Part 3 of 4.pdf PDF
Amendment 0002 - PR ER DOT PRMNT RPR(17).pdf PDF
Amendment 0002 Plans - AC-857579_HWY-258 260 261 262 263 265 - Part 1 of 4.pdf PDF
Amendment 0002 Plans - AC-857579_HWY-258 260 261 262 263 265 - Part 2 of 4.pdf PDF
Amendment 0001 Plans - AC-905579_HWY-483 - Full-Size Part 1 of 2.pdf PDF
Amendment 0001 Plans - AC-857579_HWY-258 260 261 262 263 265 - Full-Size Part 2 of 3.pdf PDF
Amendment 0001 Plans - AC-916579_HWY-286 287 - Full-Size.pdf PDF
Amendment 0001 Plans - AC-908579_HWY-257 - Full-Size.pdf PDF
Amendment 0001 Plans - AC-857579_HWY-258 260 261 262 263 265 - Full-Size Part 3 of 3.pdf PDF
Amendment 0001 Plans - AC-919579_HWY-259 - Full-Size.pdf PDF
Amendment 0001 - PR ER DOT PRMNT RPR(17).pdf PDF
Amendment 0001 Plans - AC-857579_HWY-258 260 261 262 263 265 - Full-Size Part 1 of 3.pdf PDF
Amendment 0001 Plans - AC-893579_HWY-264 - Full-Size.pdf PDF
Amendment 0001 Plans - AC-905579_HWY-483 - Full-Size Part 2 of 2.pdf PDF
Geotechnical Report - AC-857579_HWY-258 260 261 262 263 265.pdf PDF
Utility Status Report - AC-905579_HWY-483.pdf PDF
Lead Based Paint Report - AC-916579_HWY-286.pdf PDF
Geotechnical Report Addendum - AC-905579_HWY-483.pdf PDF
Lead Based Paint Report - AC-905579_HWY-483.pdf PDF
Utility Status Report - AC-857579_HWY-260 261 265.pdf PDF
Utility Status Report - AC-916579_HWY-287.pdf PDF
Plans - PR ER DOT PRMNT RPR(17) - 893579_HWY-264_plot.pdf PDF
Technical Report - AC-908579_HWY-257.pdf PDF
VETS-4212 Form.pdf PDF
Categorical Exclusion Form (NEPA) - AC-857579_HWY-258 260 261 262 263 265 (Part 1 of 2).pdf PDF
Technical Report - AC-893579_HWY-264.pdf PDF
Geotechnical Report Addendum - Letter AC-857579_HWY-260.pdf PDF
Geotechnical Report Addendum - Letter AC-857579_HWY-262.pdf PDF
Plans - PR ER DOT PRMNT RPR(17) - AC-905579_HWY-483_plot.pdf PDF
Categorical Exclusion Form (NEPA) - AC-916579_HWY-286 287.pdf PDF
Geotechnical Report Addendum - Letter AC-857579_HWY-261.pdf PDF
Categorical Exclusion Form (NEPA) - APPENDIX B_PLANS_SITE-264.pdf PDF
Lead Based Paint Report - AC-916579_HWY-287.pdf PDF
Utility Status Report - AC-908579_HWY-257.pdf PDF
Asbestos and Lead Report - AC-857579_AC-919579 (Part 3 of 3).pdf PDF
Geotechnical Report - AC-919579_HWY-259.pdf PDF
Asbestos Report - AC-908579_HWY-257.pdf PDF
PRHTAs Material Testing Schedule.PDF PDF
Utility Status Report - AC-857579_HWY-260.pdf PDF
Categorical Exclusion Form (NEPA) - AC-919579_HWY-259 (Part 2 of 2).pdf PDF
Plans - PR ER DOT PRMNT RPR(17) - 916579_HWY-286 287_plot.pdf PDF
Technical Report - AC-919579_HWY-259.pdf PDF
Carlos E. Ocasio_LBP_Exp-08.26.24.pdf PDF
Utility Status Report - AC-919579_HWY-259_PRASA.pdf PDF
Geotechnical Report Addendum - Letter 1_AC-893579_HWY-264.pdf PDF
PRHTAs Standard Drawings.pdf PDF
Show 40 more

Latest 50 of 101 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

P.O. Box 29702 San Juan, P.R 00929 phone 939-940 • 4859

ENVIRONMENTAL INVESTIGATION

FOR ASBESTOS CONTAINING BUILDING MATERIALS (ACBM)

PR-159 KM. 3.2 ER-HWY 286

GROUP B

Project: Emergency Relief Program

Landslide and Road Damages-Evaluation and

Repair Recommendation.

AC-822544

Prepared for:

Puerto Rico Highway and Transportation Authority

P.O. Box 42007

San Juan, Puerto Rico 00940-2007

Prepared by:

CMC Environmental Consultants

P.O. BOX 29702

San Juan Puerto Rico 00929-0702

December 2018

TABLE OF CONTENTS

1. INTRODUCTION

2. PROJECT DESCRIPTION

3. OBJECTIVE

4. OVERVIEW THE EVALUATION

5. INSPECTION AND SAMPLING METHODOLOGY

6. CONDITION AND LIMITATION-DISCLAIMER

7. CONCLUSION AND RECOMMENDATION

8. REPORT CERTIFICATION

APPENDIXES

1. CERTIFICATION, LICENSES, ACCREDITATION

2. CERTIFICATION OF ASBESTOS NO PRESENCE OGPE-FORM PGC-009

3. PROJECT PICTURES

4. LOCATION

1. INTRODUCTION

An Environmental investigation for asbestos containing materials (ACM) was conducted by

CMC Environmental Corp at PR-159 Km 3.2 in the Municipality of Morovis, Puerto Rico. As part Landslide and Road Damage Evaluation and Repairs project. To identify an access suspected asbestos containing materials. (ACM).

2. PROJECT DESCRIPTION

The project consists in the asbestos evaluation that included visual inspection, sampling, analysis, and physical assessment, if necessary, of suspected ACM present in the project.

In this evaluation no asbestos containing material were identified during the inspection through refer to pictures in the appendix # 3

The investigation was performed on December 20, 2018 at PR-159 Km 3.2 in the

Municipality of Morovis , Puerto Rico

During the inspection through the site no asbestos suspected material was identified for ACM.

The Asbestos School Hazard Abatement Reauthorization ASHARA, National Emission

Standard for Hazardous Air Pollutants NESHAP, Asbestos Hazard Emergency Response Act

AHERA and the Department of Natural Environmental Resources (DNER) of Puerto Rico

(Rule 422) and regulatory requirements concerning asbestos containing materials inspection/investigation shall apply.

NOTE: Samples are defined to be asbestos containing if total asbestos fibers content from

PLM analysis is greater than 1% f/cc.

3. OBJECTIVE

The objective of the asbestos investigation is to determine the presence of asbestos containing materials at the before mentioned project and assist in the compliance with the local and federal regulations prior to the demolition, repairs or rehabilitation works.

The mere presence of asbestos containing materials (ACM) and the potential for disturbance due to structure demolition or other activities create fiber release episodes into the environment that constitute a potential health hazard. Appropriate work practices or procedures for the control of emission and exposure are required by Federal and Local regulations.

4. OVERVIEW OF THE EVALUATION

This asbestos containing material inspection is to identify the location of any Asbestos containing Material (ACM) that exist within. Our scope of work (SOW) for this project consisted of the following task:

• A walk-though and visual inspection of the structure to detect the presence of any suspected material.

• Perform an inventory of suspected ACM if applicable.

• Bulk samples shall be collected from each homogeneous area within the project site if suspected material is observed (ACM).

• Polarized Light Microscopy (PLM) Analysis will be used to recognize and identify samples containing ACM.

• Final Inspection Report

The inspection was conducted with inspectors accredited by the Environmental Quality Board of Puerto Rico (EQB) and U.S Environmental Protection Agency (EPA) with experience, education and training in the recognition of potential ACM and approves bulk samples techniques.

The inspection was performance in accordance with U.S Environmental Protection Agency recommended procedures found in EPA-450/2-78-014 (Parts I and II), EPA 560/5-85-024 and

40 CFR 763, These procedures call for the visual inspection of the building for suspect friable material collection and analysis of representative’s samples of suspected materials. The EPA

Asbestos National Emission Standards for Hazards Pollutants (NESHAP) Standard define friable

ACM as any material containing over one percent (>1%) by weight of any type of asbestos mineral form that when dry, can be crumbled, pulverized, or reduced to powder by hand pressure. Non friable is any material that contain over one percentage (>1%) by weight of any type of asbestos mineral form and cannot be crumbled, pulverized, or reduced by hand pressure

P.O. Box 29702 San Juan, P.R 00929 phone 939-940 • 4859

5. INSPECTION AND SAMPLING METHODOLOGY

An initial inspection is carried out in the project site to identify the presence of any suspected material in the structure. If any ACM is not presence, no further action is required. However, if asbestos is detected, samples must be collected following EPA Procedures.

Upon complete of the functional space inspection, bulk samples were collected of the suspect

ACM and grouped into homogeneous sampling areas (areas which are uniform in color texture, general appearance and construction/application date).

When samples of homogeneous material are collected, they are labeled and transported for analysis. Each type of asbestos displays a unique property when subject to PLM. Properties are unique to crystalline asbestos form and therefore can be used to identify the type of asbestos mineral as chrysotile, amosite, crocidolite, anthophyllite, tremolite and actinolite.

Percentage of each asbestos mineral type is determined by visual estimation, by mixing the samples thoroughly to provide more accurate percentage. Any material containing over one percentage (>%) by weight of any type of asbestos mineral form is considered by the US

Environmental Agency (EPA) to be asbestos containing material and if disturbed it must be handled according to specific State and Federal Regulations.

A physical assessment of the suspected ACM was performed based on AHERA regulation. Since this protocol does not provide a method for relative ranking of individual hazards within the

AHERA categories for the three types of ACM (Surfacing, Thermal Insulation and

Miscellaneous). A separate analysis was performing as to determine the hazard assessment combines the level of potential for disturbance with the condition of the ACM. To indicate overall hazard potential the ranking for hazard potential ranges from 1 most hazardous to 7 least hazardous. The highest rank is reserved for the ACBM which is significantly damage hazard 2-4 indicate Which are damages with rank 2 indicating for significant damage and rank

3 indicating a potential of damage Hazard ranking 5-7 are reserved for ACBM in good condition.

Table 1

Asbestos Regulatory Level

Asbestos Containing Material (ACM) / >1% f/cc

Any Collected asbestos bulk samples will be submitted for standard turnaround time analysis to a Certified Proficiency by the National Institute of science and Technology NVLAP program for bulk samples asbestos analysis. The Method of analysis will be Polarized Light Microscopy with dispersion staining as recommended by US Environmental Agency (EPA).

6. CONDITIONS AND LIMITATION DISCLAIMER:

CMC Environmental has performed this investigation in a thorough and professional manner consistent with commonly accepted industry standards and practices. The preparer cannot guarantee and does not warrant that this evaluation has identified all adverse environmental factor and/ or conditions affecting this property on date of the evaluation.

The results reported and conclusions reached by the preparer are solely for the benefit of the owner. The results and opinions in this report, based solely on the conditions found at the project on the date of the evaluation, are valid only on that date. The preparer assumes no obligation to advise the client of any changes in any real or potential asbestos hazard at the project evaluated beyond the date of the inspection evaluation.

7. CONCLUSION AND RECOMMENDATION

A complete visual inspection conducted at the project site, pursuant to the requirements of

AHERA (40 CFR 763 subpart E) and USEPA guidance demonstrate that no ACM is present in the area after evaluating Project. Therefore, no samples of suspected materials containing asbestos was collected at the project-No Further action required.

8. REPORT CERTIFICATION

CMC Environmental Corp has performed this asbestos containing building material inspection in the thorough and professional manner consistent with commonly accepted industry standards.

The asbestos investigation was performed on December 20, 2018 by a EQB certified asbestos inspector Carlos M Carrion qualified by experience, education and training in the recognition of asbestos containing materials and approved sampling techniques.

Carlos M. Carrión, EQB- Asbestos Inspector

Lic. # ASB-0218-0066-SI-

Appendix #1

Certificacion Licenses Accreditations

Appendix # 2

Certification of Asbestos No Presence OGPE-Form PGC-009

Appendix # 3

Project Pictures

Appendix # 4

Location Plan

File details come from the government source that posted it. Updated .