Lead Based Paint Report - AC-916579_HWY-286.pdf

PDF 11 MB Posted

Attached to
Landslide Repairs in Morovis, Puerto Rico
Solicitation number
693C73-24-B-000015
Issued by

About this file

This document is a Request for Bids (Solicitation) for Landslide Repairs in Morovis, Puerto Rico. The project consists of repairing landslides and washouts caused by Hurricanes Irma and Maria on PR-155 and PR-159. The work includes embankment reconstruction, shotcrete wall construction, soil nail wall construction, reinforced soil slope system, gabion wall construction, mechanically stabilized earth retaining wall construction, drainage system installation, milling and overlay, pavement reconstruction, pavement markings, removal and replacement of guardrails, signage, and maintenance of traffic. The project will be split into multiple work schedules/contract options, with the cost of the entire project expected to be between $10,000,000 to $15,000,000. The solicitation is set aside for certified Small Business Concerns only. Bid documents will be issued on or about July 23, 2024, and the bid due date and location will be specified in the solicitation. Interested vendors must register at www.sam.gov to receive notifications and access bid documents. Prospective contractors must be registered in the System for Award Management (SAM) database at the time an offer is submitted.

View the file

Other files

File Type Posted
Results of Bid Opening - PR ER DOT PRMNT RPR(17).pdf PDF
Amendment 0004 - PR ER DOT PRMNT RPR(17).pdf PDF
Amendment 0003 - PR ER DOT PRMNT RPR(17).pdf PDF
Amendment 0002 Plans - AC-857579_HWY-258 260 261 262 263 265 - Part 4 of 4.pdf PDF
Amendment 0002 Plans - AC-857579_HWY-258 260 261 262 263 265 - Part 3 of 4.pdf PDF
Amendment 0002 - PR ER DOT PRMNT RPR(17).pdf PDF
Amendment 0002 Plans - AC-857579_HWY-258 260 261 262 263 265 - Part 1 of 4.pdf PDF
Amendment 0002 Plans - AC-857579_HWY-258 260 261 262 263 265 - Part 2 of 4.pdf PDF
Amendment 0001 Plans - AC-905579_HWY-483 - Full-Size Part 1 of 2.pdf PDF
Amendment 0001 Plans - AC-857579_HWY-258 260 261 262 263 265 - Full-Size Part 2 of 3.pdf PDF
Amendment 0001 Plans - AC-916579_HWY-286 287 - Full-Size.pdf PDF
Amendment 0001 Plans - AC-908579_HWY-257 - Full-Size.pdf PDF
Amendment 0001 Plans - AC-857579_HWY-258 260 261 262 263 265 - Full-Size Part 3 of 3.pdf PDF
Amendment 0001 Plans - AC-919579_HWY-259 - Full-Size.pdf PDF
Amendment 0001 - PR ER DOT PRMNT RPR(17).pdf PDF
Amendment 0001 Plans - AC-857579_HWY-258 260 261 262 263 265 - Full-Size Part 1 of 3.pdf PDF
Amendment 0001 Plans - AC-893579_HWY-264 - Full-Size.pdf PDF
Amendment 0001 Plans - AC-905579_HWY-483 - Full-Size Part 2 of 2.pdf PDF
Geotechnical Report - AC-857579_HWY-258 260 261 262 263 265.pdf PDF
Utility Status Report - AC-905579_HWY-483.pdf PDF
Geotechnical Report Addendum - AC-905579_HWY-483.pdf PDF
Lead Based Paint Report - AC-905579_HWY-483.pdf PDF
Utility Status Report - AC-857579_HWY-260 261 265.pdf PDF
Utility Status Report - AC-916579_HWY-287.pdf PDF
Plans - PR ER DOT PRMNT RPR(17) - 893579_HWY-264_plot.pdf PDF
Technical Report - AC-908579_HWY-257.pdf PDF
VETS-4212 Form.pdf PDF
Categorical Exclusion Form (NEPA) - AC-857579_HWY-258 260 261 262 263 265 (Part 1 of 2).pdf PDF
Technical Report - AC-893579_HWY-264.pdf PDF
Geotechnical Report Addendum - Letter AC-857579_HWY-260.pdf PDF
Geotechnical Report Addendum - Letter AC-857579_HWY-262.pdf PDF
Plans - PR ER DOT PRMNT RPR(17) - AC-905579_HWY-483_plot.pdf PDF
Categorical Exclusion Form (NEPA) - AC-916579_HWY-286 287.pdf PDF
Geotechnical Report Addendum - Letter AC-857579_HWY-261.pdf PDF
Categorical Exclusion Form (NEPA) - APPENDIX B_PLANS_SITE-264.pdf PDF
Lead Based Paint Report - AC-916579_HWY-287.pdf PDF
Utility Status Report - AC-908579_HWY-257.pdf PDF
Asbestos and Lead Report - AC-857579_AC-919579 (Part 3 of 3).pdf PDF
Geotechnical Report - AC-919579_HWY-259.pdf PDF
Asbestos Report - AC-908579_HWY-257.pdf PDF
PRHTAs Material Testing Schedule.PDF PDF
Utility Status Report - AC-857579_HWY-260.pdf PDF
Categorical Exclusion Form (NEPA) - AC-919579_HWY-259 (Part 2 of 2).pdf PDF
Plans - PR ER DOT PRMNT RPR(17) - 916579_HWY-286 287_plot.pdf PDF
Technical Report - AC-919579_HWY-259.pdf PDF
Carlos E. Ocasio_LBP_Exp-08.26.24.pdf PDF
Utility Status Report - AC-919579_HWY-259_PRASA.pdf PDF
Geotechnical Report Addendum - Letter 1_AC-893579_HWY-264.pdf PDF
PRHTAs Standard Drawings.pdf PDF
Technical Report - AC-916579_HWY-287.pdf PDF
Show 40 more

Latest 50 of 101 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

P.O. Box 29702 San Juan, P.R 00929 phone 939-940 • 4859

ENVIRONMENTAL INVESTIGATION FOR LEAD BASED PAINT

PR-159 KM. 3.2 ER-HWY 286

GROUP B

Project: Emergency Relief Program

Landslide and Road Damages-Evaluation and

Repair Recommendation.

AC-822544

Prepared for:

Puerto Rico Highway and Transportation Authority

P.O. Box 42007

San Juan, Puerto Rico 00940-2007

Prepared by:

CMC Environmental Consultants

P.O. BOX 29702

San Juan Puerto Rico 00929-0702

December 2018

P.O. Box 29702 San Juan, P.R 00929 phone 939-940 • 4859

TABLE OF CONTENTS

1. Introduction

2. Project Description

3. Overview of Evaluation

4. Equipment Information

5. Sampling Procedures and Results Presentation

6. Sampling Methodology and Analysis

7. Conditions and Limitation Disclaimer

8. Lead Based Paint Testing Methodology

9. Results

10. Abatement Conditions

11. Conclusion-Recommendations

12. LBP Report Certification

Appendixes:

1. Certification Licenses, Accreditations.

2. Lead Based Paint Testing Form.

3. XRF Performance Characteristics Sheet (PCS)

4. Pictures

5. Certification of No Lead based Paint Presence OGPE-Form PGC-010

6. Location Map

I. INTRODUCTION

An environmental lead-based paint inspection was conducted by CMC Environmental Corp at PR-159 Km. 3.2 located in the Municipality of Morovis, P.R. Puerto Rico.

The Lead Based Paint Inspection was conducted on December 20, of 2018 by a Certified

Inspector/ Risk Assessor Carlos M Carrion using an RMD LPA-1 X Ray Analyzer (XRF) serial

# 2526 and consisted of an identify paint that contain lead-based paint above allowable levels and help with the compliance of local and federal regulations.

II. PROJECT DESCRIPTION

The lead-based paint inspection was conducted at PR-159 Km 3.2 located in the

Municipality of Morovis, Puerto Rico. and consisted in Landslide and Road Damage

Evaluation repair and recommendations The inspection is to evaluate, access and identify all painted surfaces such as Road Lines Guardrails etc. using a RMD LPA-1 XRF Analyzer and following the methodology conforming to Department of Housing and Urban

Development (H.U.D) inspection protocol Chapter 7 revised in 2012 and the Environmental

Quality Board of Puerto Rico (EQB).

The evaluation found that lead based painted surface above regulatory limits was not present on the date of evaluation.

III. OVERVIEW OF THE EVALUATION

The lead-based paint inspection is an investigation to identify all lead-based paint on a surface-by-surface basis. CMC Environmental Corp were inspected this project utilizing the Housing and Urban

Development (H.U.D.) inspection protocols revised (2012), and The Environmental Quality Board of P.R. (EQB).). Samples were taken at identified surfaces of the evaluated areas using Xray fluorescence (XRF) analyzer. The evaluation found that lead based paint was not present in components and surfaces tested through the site project on the date of the inspection.

Lead based paint inspection was performed by E.P.A. Model trained Lead Based Paint Inspector/

Risk Assessor Carlos M. Carrion, Certified by Environmental Quality Board of Puerto Rico (EQB), utilizing RMD LPA-1 Analyzer serial # 2526 the credential is provided in Appendix #1 (Certification, Licenses and Accreditations).

The RMD LPA-1 XRF analyzer is designed to measure the lead of surface coating on a variety of surfaces, substrates and components the measure is rapid and non- destructive and according to the manufacturer, is capable of detecting lead concentration that occur within numerous layers of various surface coatings.

IV. EQUIPMENT INFORMATION

XRF Spectrum Analyzer- LPA-1 Inspection System by RMD

X Ray Source- Co 57 (10mci)

Serial Number 2526

V. SAMPLING PROCEDURES AND RESULTS PRESENTATION

The lead-based paint sampling procedures was design to evaluate and document all data obtained in the investigation in a sequential method that provided confidence at the moment of the results presentation.

The Lead Based Paint inspection was conducted following the U.S Department of Housing (H.U.D.)

Established in the Guidelines for the Evaluation and Control of Lead Based Paint in Housing (2012) and the Environmental Quality Board of Puerto Rico (EQB).

The Consumer Products Safety Commission (CPSC) has defined lead-based paint as containing 1.0 mg/cm² or more lead when analyzed by the XRF. The surfaces evaluation was performed as follow:

The standard operating procedure for XRF testing was performed as follows:

If lead concentration measured by XRF florescence Analyzer is less than (1.0 mg/ cm ²) the result is considered negative.

If the lead concentration measured by XRF florescence Analyzer is equal or greater than 1.0 mg

/ cm² the result is considering positive.

Inconclusive reading is generated from lead concentration measured by LPA-1 Lead Analyzer, except for metal substrate as per PCS for RMD is .8 to .9 mg/cm²

Each area within the dwelling units was assigned a room name and number (According to this use) within the room, a letter code was assigned to each surface area being tested.

Each letter code was assigned from left to right, clockwise, as the room was being entered.

The wall assigned the letter code A is the one to the left of the inspector when entering the room.

The Wall that is left behind the inspector as he enters the room usually the last wall and is labeled wall D. The wall in front of the inspector is labeled Wall B and the Wall to the right of inspector is labeled Wall C.

The lead regulatory levels provided below are those used when preparing this lead-based paint evaluation or when evaluating data collected. The EPA regulatory levels are the same as the state regulatory levels provided in the following table.

Table # 1 Lead Regulatory Levels:

EPA/DNER Levels

Lead Based Paint 1.0mg/cm² or 0.5% by weight or 5,000ppm

VI. SAMPLING METHODOLOGY AND ANALYSIS

The standard operating procedure for XRF testing was performed as follows:

A representative surface of each area with different paint covering and different surfaces were tested, (i.e., Road lines, etc.).

No paint chips samples were collected for laboratory analysis no lead measurements were inconclusive. Reading recorded on LBP Testing Data Sheet that contains a brief description of the area sampled per areas.

A full description of component types, substrate, color, location and XRF reading by the spectrum analyzer is provided for each area tested.

The components and areas that resulted negative for LBP (below 1.0mg/ cm²) except for those surfaces areas described in Section 2 of the summary of this report.

VII. CONDITIONS AND LIMITATION DISCLAIMER

CMC Environmental has performed this investigation in a thorough and professional manner consistent with commonly accepted industry standards and practices. The preparer cannot guarantee and does not warrant that this evaluation has identified all adverse environmental factor and/ or conditions affecting this property on date of the evaluation.

The results reported and conclusions reached by the preparer are solely for the benefit of the owner. The results and opinions in this report, based solely on the conditions found at the property (project) on the date of the evaluation, are valid only on that date. The preparer assumes no obligation to advise the client of any changes in any real or potential lead hazard at the structures evaluated beyond the date of the inspection report.

VIII. LEAD BASED PAINT TESTING METHODOLOGY

The hazard level of Lead Based Paint has been determined by the Department of Housing

& Urban Development as 1.0 mg/cm2 as measured by XRF or AAS (Atomic Absorption

Spectroscopy) or 0.5% by weight (or 5000 PPM) as measured by AAS or Induct Coupled plasma (ICP). The same level was adopted by Environmental Protection Agency (E.P.A.)

Regulation Published in 1992, under Title X, the only Lead Based Paint testing protocol officially available at this time was published by Housing and Urban Development (HUD).

Initially in 1990, revised in 1991 and finalized in 1995. A revised chapter VII was published in 1997 and revised 2012 In accordance to new protocol almost all surface present in the units have to be tested the above guidelines were used to perform Lead Based Paint testing for this project.

IX. XRF RESULTS

Refers to XRF lead based paint testing form for the detailed analytical testing results for each distinct areas inspected in appendix #2.

X. ABATEMENT CONDITIONS

Abatement is defined by HUD and the Department of Natural Resources and Environment

(DRNA) of Puerto Rico, means any set of measures designed to eliminate lead-based paint and/or lead based paint hazards permanently. The People providing these services must to be trained in accordance with DRNA licensing /certification requirements product manufacturer and/or contractor must warrant abatement methods to last a minimum of

Twenty (20) years or these methods must have design life at least 20 years.

Abatement activities may include, but are not necessarily limited to:

• On-site or off-site removal of lead-based paint (LBP) from substrate and components

• Replacement of components or fixtures painted with lead-based paint (LBP).

• Permanent enclosure of lead-based paint (LBP) with construction materials mechanically fastened to the substrate.

• Encapsulation of lead-based paint with specially designed encapsulant products.

• Removal or permanent covering (concrete or asphalt) of soil lead based paint hazards.

If enclosure or encapsulation is conducted as an abatement method, the lead-based paint remains on the property, so ongoing paint maintenance plan is required.

XI. CONCLUSION-RECOMMENDATIONS

Complete visual inspection conducted at the project site, pursuant to the E.P.A H.U.D. regulatory levels and the Environmental Quality Board of P.R. (EQB) lead regulation demonstrate that lead-based paint components above the regulatory levels is not present in the area after evaluating

Landslide and Road Damages and Repairs project PR-159 km 3.2 Therefore, no further action is required.

Finally Based on the lead-based paint XRF field testing data generated during the paint inspection conducted lead-based paint above the regulatory limits of

1.0 mg/cm² was not found in this project.

XII. REPORT CERTIFICATION

CMC Environmental Corp has performed this lead-based paint inspection in the thorough and professional manner consistent with commonly accepted industry standards. The lead-based paint investigation was performed on December 20, 2018 by a EQB Certified

Risk Assessor Carlos M Carrion qualified by experience, education and training in the recognition of LBP and approved sampling techniques.

Carlos M. Carrión Montalvo

EQB Cert # 1303-0418-RA-004

APPENDIX #1

Certification Licenses, Accreditations.

APPENDIX #2

Lead Based Paint Testing Form.

APPENDIX #3

XRF Performance Characteristics Sheet (PCS)

APPENDIX #4

Project Pictures

APPENDIX #5

Certification of No Lead based Paint Presence OGPE-Form PGC-010

APPENDIX #6