Appendix F - ICE Dwg Stnds.pdf
PDF 6 MB Posted
- Attached to
- Single Award Construction Contract (SACC) Indefinite Delivery Indefinite Quantity (IDIQ)s Federal contract opportunity
- Solicitation number
- 70CMSW26R00000012
- Issued by
- Immigration and Customs Enforcement
About this file
This document is Appendix F containing Ice Drawing Standards for detention facility construction, specifically detailing architectural and security specifications for the U.S. Immigration and Customs Enforcement (ICE) Service Processing Center. The standards present detailed technical drawings and specifications for three types of security walls: High Security Wall Type (01-101), Medium Security Wall Type (01-102), and Low Security Wall Type (01-103), each featuring reinforced concrete masonry construction with varying specifications for vertical rebars, dowelled bars, and bracing configurations. The drawings include security wall type adjacencies matrices indicating appropriate applications for different facility areas including dayrooms, corridors, cells, multi-purpose rooms, janitor spaces, utility rooms, storage, exterior areas, and showers, with designations for High (H), Medium (M), and Low (L) security requirements.
Additional specifications cover typical detainee cell plans with concrete masonry construction (01-201), accessible cell configurations (01-202), and precast concrete modular cells (01-203), along with detailed elevation drawings for cell furnishings and windows. The standards also provide comprehensive details for security components including fencing types (01-102 through 02-117), vehicular sallyport designs, traffic control gates, buried fabric details, and various penetration treatments. Detention hollow metal frame details (11-201 through 11-227) address frame anchors, glazing, jamb conditions, door specifications, window mullions, and safety hardware installations. Additional details cover cell bunks, shelf/safety hook installations, grab bar specifications, wall-mounted stool anchors, and steel table bases. Mechanical and security system details include negative pressure isolation room layouts (15-101), duct penetration barriers for secure walls (15-201), secure air distribution devices (15-202), and fire damper penetration specifications (15-203) with comprehensive notes regarding security barrier requirements and installation methods.
View the file
Other files for this federal contract opportunity
Show all 47
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
m2pmjmm9 Text Box m2pmjmm9 Text Box
APPENDIX F
ICE DRAWING STANDARDS
File details come from the government source that posted it. Updated .