This document provides specifications for the Restore Outfitting Capacity, Berth 6C project at the Portsmouth Naval Shipyard in Kittery, Maine. The solicitation requests bids for the design-bid-build construction of repairs and upgrades to Berth 6C to restore its outfitting capacity. Interested vendors are invited to respond with fixed-price bids by the specified due date. The work includes structural, mechanical, electrical, and civil repairs and replacements. The Navy seeks a single prime contractor to complete the project by the required date while meeting all material, testing, and reporting requirements.
View the file
Other files for this federal contract opportunity
Show all 34
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
INSTRUCTIONS
MODEL AND FACILITY DATA MATRIX
| MODEL AND FACILITY DATA MATRIX | |||||
| STEP 1: | Is This a BIM Project? | No | Modeling Requirements | Required Facility Asset Fields | |
| STEP 2: | Select Yes or No in Column E for each MASTERSYSTEM, SYSTEM and SUBSYSTEM that is In the Project Scope | DESIGN MODEL | RECORD MODEL |
(AS-BUILT)
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 14 | 15 | 16 | 17 | |||||||||||
| CLASSIFICATION | ||||||||||||||||||||||||||||
| ID | MASTERSYSTEM / SYSTEM / SUBSYSTEM Name | System Type | UOM | In Scope | ||||||||||||||||||||||||
| (Yes or No) | DISCIPLINE | LOD | GRADE | LOD | ||||||||||||||||||||||||
| (AB) | GRADE | AssetNum | Description | Long Description | MASTERSYSTEM | SYSTEM | SUBSYSTEM | Building Number | Asset Quantity | Replacement Cost | Contract Number | Task/Delivery Order Number | Warranty Expiration Date | Installation Date | CLASSIFICATIONID | Room Number | Manufacturer | Model | Serial # | |||||||||
| A10 | A10 - FOUNDATIONS | MASTERSYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| A1010 | A1010 - STANDARD FOUNDATIONS | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| A1010110 | A1010110 - STRIP FOOTINGS | SUBSYSTEM | LF | No | STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| A1010210 | A1010210 - SPREAD FOOTINGS | SUBSYSTEM | EA | No | STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| A1010250 | A1010250 - PILE CAPS | SUBSYSTEM | EA | No | STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| A1010999 | A1010999 - OTHER | SUBSYSTEM | EA | No | ||||||||||||||||||||||||
| A1020 | A1020 - SPECIAL FOUNDATIONS | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| A102005 | A102005 - RAFT FOUNDATIONS | SUBSYSTEM | CY | No | STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| A1020110 | A1020110 - CIP CONCRETE PILES | SUBSYSTEM | EA | No | STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| A1020120 | A1020120 - PRECAST CONCRETE PILES | SUBSYSTEM | EA | No | STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| A1020130 | A1020130 - STEEL PIPE PILES | SUBSYSTEM | EA | No | STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| A1020140 | A1020140 - STEEL H PILES | SUBSYSTEM | EA | No | STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| A1020160 | A1020160 - TREATED WOOD PILES | SUBSYSTEM | EA | No | STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| A1020210 | A1020210 - GRADE BEAMS | SUBSYSTEM | LF | No | STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| A1020999 | A1020999 - OTHER | SUBSYSTEM | EA | No | ||||||||||||||||||||||||
| A1030 | A1030 - SLAB ON GRADE | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| A1030120 | A1030120 - PLAIN/REINFORCED | SUBSYSTEM | SF | No | STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| A1030999 | A1030999 - OTHER | SUBSYSTEM | EA | No | ||||||||||||||||||||||||
| A20 | A20 - BASEMENT CONSTRUCTION | MASTERSYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| A2010 | A2010 - BASEMENT EXCAVATION | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| A2010999 | A2010999 - OTHER BASEMENT EXCAVATION | SUBSYSTEM | EA | No | ||||||||||||||||||||||||
| A2020 | A2020 - BASEMENT WALLS | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| A2020110 | A2020110 - CIP CONCRETE | SUBSYSTEM | LF | No | STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| A2020140 | A2020140 - CONCRETE BLOCK | SUBSYSTEM | LF | No | STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| A2020150 | A2020150 - WOOD | SUBSYSTEM | LF | No | STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| A2020999 | A2020999 - OTHER | SUBSYSTEM | LF | No | ||||||||||||||||||||||||
| B10 | B10 - SUPERSTRUCTURE | MASTERSYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| B1010 | B1010 - FLOOR CONSTRUCTION | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| B1010220 | B1010220 - CIP CONCRETE BEAM AND SLAB | SUBSYSTEM | SF | No | STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| B1010238 | B1010238 - PRECAST CONCRETE BEAM AND PLANK | SUBSYSTEM | SF | No | STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| B1010244 | B1010244 - LIGHT GAUGE STEEL FLOOR SYSTEM | SUBSYSTEM | SF | No | STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| B1010250 | B1010250 - COMPOSITE DECK, STEEL BAR JOISTS | SUBSYSTEM | SF | No | STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| B1010254 | B1010254 - COMP DECK, STRUCTURAL STEEL BEAM | SUBSYSTEM | SF | No | STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| B1010264 | B1010264 - WOOD BEAM, JOIST, AND DECK | SUBSYSTEM | SF | No | STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| B1010998 | B1010998 - EXTERIOR STAIRS | SUBSYSTEM | FLIGHT | No | STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| B1010999 | B1010999 - OTHER | SUBSYSTEM | SF | No | ||||||||||||||||||||||||
| B1020 | B1020 - ROOF CONSTRUCTION | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| B1020102 | B1020102 - WOOD DECK AND RAFTER | SUBSYSTEM | SF | No | STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| B1020108 | B1020108 - STEEL DECK, BEAMS AND BAR JOIST | SUBSYSTEM | SF | No | STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| B1020122 | B1020122 - CIP CONCRETE ROOF CONSTRUCTION | SUBSYSTEM | SF | No | STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| B1020137 | B1020137 - AWNING/CANOPY | SUBSYSTEM | SF | No | STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| B1020901 | B1020901 - CIP CONCRETE BEAM AND SLAB | SUBSYSTEM | SF | No | STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| B1020902 | B1020902 - PRECAST CONCRETE BEAM AND PLANK | SUBSYSTEM | SF | No | STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| B1020999 | B1020999 - OTHER | SUBSYSTEM | SF | No | ||||||||||||||||||||||||
| B1030 | B1030 - ROOF CONSTRUCTION | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| B103001 | B103001 - METAL STRUCTURAL FRAME | SUBSYSTEM | LF | No | STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| B20 | B20 - EXTERIOR ENCLOSURE | MASTERSYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| B2010 | B2010 - EXTERIOR WALLS | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| B2010101 | B2010101 - CIP CONCRETE | SUBSYSTEM | SF | No | STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| B2010104 | B2010104 - PRECAST CONCRETE PANEL (RIBBED) | SUBSYSTEM | SF | No | STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| B2010106 | B2010106 - PRECAST CONCRETE PANEL (TILT UP) | SUBSYSTEM | SF | No | STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| B2010109 | B2010109 - CONCRETE BLOCK | SUBSYSTEM | SF | No | STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| B2010125 | B2010125 - SOLID BRICK - SINGLE WYTHE | SUBSYSTEM | SF | No | STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| B2010126 | B2010126 - SOLID BRICK - DOUBLE WYTHE | SUBSYSTEM | SF | No | STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| B2010128 | B2010128 - STONE VENEER W/STUD BACKUP | SUBSYSTEM | SF | No | ARCHITECTURAL, STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| B2010130 | B2010130 - BRICK VENEER W/STUD BACKUP | SUBSYSTEM | SF | No | ARCHITECTURAL, STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| B2010132 | B2010132 - MASONRY COMPOSITE | SUBSYSTEM | SF | No | STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| B2010134 | B2010134 - MASONRY CAVITY | SUBSYSTEM | SF | No | ARCHITECTURAL, STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| B2010140 | B2010140 - GLASS BLOCK | SUBSYSTEM | SF | No | ARCHITECTURAL | 300 | A | A+ | ||||||||||||||||||||
| B2010146 | B2010146 - METAL SIDING PANEL | SUBSYSTEM | SF | No | ARCHITECTURAL | 300 | A | A+ | ||||||||||||||||||||
| B2010148 | B2010148 - WOOD CLADDING W/STUD BACKUP | SUBSYSTEM | SF | No | ARCHITECTURAL, STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| B2010151 | B2010151 - STUCCO WALL | SUBSYSTEM | SF | No | ARCHITECTURAL | 300 | A | A+ | ||||||||||||||||||||
| B2010152 | B2010152 - E.I.F.S. | SUBSYSTEM | SF | No | ARCHITECTURAL | 300 | A | A+ | ||||||||||||||||||||
| B2010999 | B2010999 - OTHER | SUBSYSTEM | SF | No | ||||||||||||||||||||||||
| B2020 | B2020 - EXTERIOR GLAZED OPENINGS | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| B2020102 | B2020102 - WOOD WINDOWS | SUBSYSTEM | EA | No | ARCHITECTURAL | 300 | A | A+ | ||||||||||||||||||||
| B2020104 | B2020104 - STEEL WINDOWS | SUBSYSTEM | EA | No | ARCHITECTURAL | 300 | A | A+ | ||||||||||||||||||||
| B2020106 | B2020106 - ALUMINUM WINDOWS | SUBSYSTEM | EA | No | ARCHITECTURAL | 300 | A | A+ | ||||||||||||||||||||
| B2020210 | B2020210 - TUBULAR ALUMINUM FRAMING | SUBSYSTEM | SF | No | ARCHITECTURAL | 300 | A | A+ | ||||||||||||||||||||
| B2020220 | B2020220 - CURTAIN WALL PANELS | SUBSYSTEM | SF | No | ARCHITECTURAL, STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| B2020999 | B2020999 - OTHER | SUBSYSTEM | SF | No | ||||||||||||||||||||||||
| B2030 | B2030 - EXTERIOR DOORS | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| B2030110 | B2030110 - GLAZED DOORS | SUBSYSTEM | EA | No | ARCHITECTURAL | 300 | A | A+ | ||||||||||||||||||||
| B2030210 | B2030210 - WOOD DOORS | SUBSYSTEM | EA | No | ARCHITECTURAL | 300 | A | A+ | ||||||||||||||||||||
| B2030220 | B2030220 - STEEL DOORS | SUBSYSTEM | EA | No | ARCHITECTURAL | 300 | A | A+ | ||||||||||||||||||||
| B2030230 | B2030230 - ALUMINUM DOORS | SUBSYSTEM | EA | No | ARCHITECTURAL | 300 | A | A+ | ||||||||||||||||||||
| B2030410 | B2030410 - OVERHEAD DOORS | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| B2030901 | B2030901 - HANGAR DOORS | SUBSYSTEM | SF | No | ARCHITECTURAL | 300 | A | A+ | ||||||||||||||||||||
| B2030902 | B2030902 - BLAST RESISTANT DOORS | SUBSYSTEM | EA | No | ARCHITECTURAL | 300 | A | A+ | ||||||||||||||||||||
| B2030999 | B2030999 - OTHER | SUBSYSTEM | EA | No | ||||||||||||||||||||||||
| B30 | B30 - ROOFING | MASTERSYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| B3010 | B3010 - ROOF COVERING | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| B3010105 | B3010105 - BUILT-UP | SUBSYSTEM | SF | No | ARCHITECTURAL | 200 | A | A+ | ||||||||||||||||||||
| B3010120 | B3010120 - SINGLE PLY MEMBRANE | SUBSYSTEM | SF | No | ARCHITECTURAL | 200 | A | A+ | ||||||||||||||||||||
| B3010130 | B3010130 - PREFORMED METAL | SUBSYSTEM | SF | No | ARCHITECTURAL | 200 | A | A+ | ||||||||||||||||||||
| B3010135 | B3010135 - FORMED METAL | SUBSYSTEM | SF | No | ARCHITECTURAL | 200 | A | A+ | ||||||||||||||||||||
| B3010140 | B3010140 - SHINGLE TILE | SUBSYSTEM | SF | No | ARCHITECTURAL | 200 | A | A+ | ||||||||||||||||||||
| B3010320 | B3010320 - ROOF DECK INSULATION | SUBSYSTEM | SF | No | ARCHITECTURAL | 200 | A | A+ | ||||||||||||||||||||
| B3010610 | B3010610 - GUTTERS | SUBSYSTEM | LF | No | ARCHITECTURAL | 200 | A | A+ | ||||||||||||||||||||
| B3010620 | B3010620 - DOWNSPOUTS | SUBSYSTEM | LF | No | ARCHITECTURAL | 200 | A | A+ | ||||||||||||||||||||
| B3010999 | B3010999 - OTHER | SUBSYSTEM | No | |||||||||||||||||||||||||
| B3020 | B3020 - ROOF OPENING | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| B3020110 | B3020110 - SKYLIGHTS | SUBSYSTEM | SF | No | ARCHITECTURAL | 300 | A | A+ | ||||||||||||||||||||
| B3020210 | B3020210 - HATCHES | SUBSYSTEM | EA | No | ARCHITECTURAL | 300 | A | A+ | ||||||||||||||||||||
| B3020999 | B3020999 - OTHER | SUBSYSTEM | No | |||||||||||||||||||||||||
| C10 | C10 - INTERIOR CONSTRUCTION | MASTERSYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| C1010 | C1010 - PARTITIONS | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| C1010102 | C1010102 - CONCRETE BLOCK | SUBSYSTEM | SF | No | ARCHITECTURAL | 300 | A | A+ | ||||||||||||||||||||
| C1010120 | C1010120 - TILE | SUBSYSTEM | SF | No | ARCHITECTURAL | 300 | A | A+ | ||||||||||||||||||||
| C1010126 | C1010126 - DRYWALL W/STUD FRAMING | SUBSYSTEM | SF | No | ARCHITECTURAL | 300 | A | A+ | ||||||||||||||||||||
| C1010140 | C1010140 - PLASTER W/STUD FRAMING | SUBSYSTEM | SF | No | ARCHITECTURAL | 300 | A | A+ | ||||||||||||||||||||
| C1010710 | C1010710 - INTERIOR WINDOWS | SUBSYSTEM | EA | No | ARCHITECTURAL | 300 | A | A+ | ||||||||||||||||||||
| C1010999 | C1010999 - OTHER | SUBSYSTEM | EA | No | ||||||||||||||||||||||||
| C1020 | C1020 - INTERIOR DOORS | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| C1020102 | C1020102 - SPECIAL DOORS | SUBSYSTEM | EA | No | ARCHITECTURAL | 300 | A | A+ | ||||||||||||||||||||
| C1020111 | C1020111 - FIRE DOOR, SWINGING | SUBSYSTEM | EA | No | ARCHITECTURAL | 300 | A | A+ | ||||||||||||||||||||
| C1020112 | C1020112 - FIRE DOOR, SLIDING | SUBSYSTEM | EA | No | ARCHITECTURAL | 300 | A | A+ | ||||||||||||||||||||
| C1020113 | C1020113 - FIRE DOOR, ROLLING SERVICE/ROLL-UP | SUBSYSTEM | EA | No | ARCHITECTURAL | 300 | A | A+ | ||||||||||||||||||||
| C1020114 | C1020114 - METAL DOOR | SUBSYSTEM | EA | No | ARCHITECTURAL | 300 | A | A+ | ||||||||||||||||||||
| C1020120 | C1020120 - WOOD DOOR/WOOD FRAME | SUBSYSTEM | EA | No | ARCHITECTURAL | 300 | A | A+ | ||||||||||||||||||||
| C1020122 | C1020122 - WOOD DOOR/METAL FRAME | SUBSYSTEM | EA | No | ARCHITECTURAL | 300 | A | A+ | ||||||||||||||||||||
| C1020124 | C1020124 - WOOD FIRE DOORS/METAL FRAMES | SUBSYSTEM | EA | No | ARCHITECTURAL | 300 | A | A+ | ||||||||||||||||||||
| C1020301 | C1020301 - BLAST RESISTANT DOOR | SUBSYSTEM | EA | No | ARCHITECTURAL | 300 | A | A+ | ||||||||||||||||||||
| C1020999 | C1020999 - OTHER | SUBSYSTEM | EA | No | ||||||||||||||||||||||||
| C1030 | C1030 - FITTINGS | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| C1030110 | C1030110 - TOILET PARTITIONS | SUBSYSTEM | EA | No | ARCHITECTURAL | 300 | A | A+ | ||||||||||||||||||||
| C1030310 | C1030310 - LOCKERS | SUBSYSTEM | EA | No | ARCHITECTURAL | 300 | A | A+ | ||||||||||||||||||||
| C1030830 | C1030830 - CABINETS | SUBSYSTEM | LF | No | ARCHITECTURAL | 300 | A | A+ | ||||||||||||||||||||
| C1030831 | C1030831 - COUNTERTOP | SUBSYSTEM | LF | No | ARCHITECTURAL | 300 | A | A+ | ||||||||||||||||||||
| C1030999 | C1030999 - OTHER | SUBSYSTEM | LF | No | ||||||||||||||||||||||||
| C20 | C20 - STAIRS | MASTERSYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| C2010 | C2010 - STAIR CONSTRUCTION | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| C2010110 | C2010110 - STAIRS | SUBSYSTEM | FLIGHT | Yes | ARCHITECTURAL | 300 | A | A+ | ||||||||||||||||||||
| C2010999 | C2010999 - OTHER | SUBSYSTEM | EA | No | ||||||||||||||||||||||||
| C2020 | C2020 - STAIR FINISHES | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| C2020999 | C2020999 - OTHER STAIR FINISHES | SUBSYSTEM | EA | No | ||||||||||||||||||||||||
| C30 | C30 - INTERIOR FINISHES | MASTERSYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| C3010 | C3010 - WALL FINISHES | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| C3010230 | C3010230 - WALL COVERING | SUBSYSTEM | SF | No | ARCHITECTURAL | 100 | B | B+ | ||||||||||||||||||||
| C3010380 | C3010380 - WALL TILE | SUBSYSTEM | SF | No | ARCHITECTURAL | 100 | B | B+ | ||||||||||||||||||||
| C3010999 | C3010999 - OTHER | SUBSYSTEM | SF | No | ||||||||||||||||||||||||
| C3020 | C3020 - FLOORING | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| C3020901 | C3020901 - CARPET | SUBSYSTEM | SF | No | ARCHITECTURAL | 100 | B | B+ | ||||||||||||||||||||
| C3020902 | C3020902 - CARPET TILE | SUBSYSTEM | SF | No | ARCHITECTURAL | 100 | B | B+ | ||||||||||||||||||||
| C3020903 | C3020903 - COMPOSITION SHEET | SUBSYSTEM | SF | No | ARCHITECTURAL | 100 | B | B+ | ||||||||||||||||||||
| C3020904 | C3020904 - CONCRETE TOPPING | SUBSYSTEM | SF | No | ARCHITECTURAL | 100 | B | B+ | ||||||||||||||||||||
| C3020905 | C3020905 - WOOD | SUBSYSTEM | SF | No | ARCHITECTURAL | 100 | B | B+ | ||||||||||||||||||||
| C3020906 | C3020906 - TERRAZZO | SUBSYSTEM | SF | No | ARCHITECTURAL | 100 | B | B+ | ||||||||||||||||||||
| C3020907 | C3020907 - VINYL TILE | SUBSYSTEM | SF | No | ARCHITECTURAL | 100 | B | B+ | ||||||||||||||||||||
| C3020908 | C3020908 - CORK TILE | SUBSYSTEM | SF | No | ARCHITECTURAL | 100 | B | B+ | ||||||||||||||||||||
| C3020909 | C3020909 - RUBBER SHEET | SUBSYSTEM | SF | No | ARCHITECTURAL | 100 | B | B+ | ||||||||||||||||||||
| C3020910 | C3020910 - PORCELAIN TILE | SUBSYSTEM | SF | No | ARCHITECTURAL | 100 | B | B+ | ||||||||||||||||||||
| C3020911 | C3020911 - QUARRY TILE | SUBSYSTEM | SF | No | ARCHITECTURAL | 100 | B | B+ | ||||||||||||||||||||
| C3020912 | C3020912 - PAINT | SUBSYSTEM | SF | No | ARCHITECTURAL | 100 | B | B+ | ||||||||||||||||||||
| C3020913 | C3020913 - MARBLE TILE | SUBSYSTEM | SF | No | ARCHITECTURAL | 100 | B | B+ | ||||||||||||||||||||
| C3020914 | C3020914 - CERAMIC TILE | SUBSYSTEM | SF | No | ARCHITECTURAL | 100 | B | B+ | ||||||||||||||||||||
| C3020915 | C3020915 - ACCESS FLOORING | SUBSYSTEM | SF | No | ARCHITECTURAL | 100 | B | B+ | ||||||||||||||||||||
| C3020999 | C3020999 - OTHER | SUBSYSTEM | No | |||||||||||||||||||||||||
| C3030 | C3030 - CEILING FINISHES | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| C3030105 | C3030105 - PLASTER | SUBSYSTEM | SF | No | ARCHITECTURAL | 200 | A | A+ | ||||||||||||||||||||
| C3030110 | C3030110 - DRYWALL | SUBSYSTEM | SF | No | ARCHITECTURAL | 200 | A | A+ | ||||||||||||||||||||
| C3030210 | C3030210 - ACOUSTICAL | SUBSYSTEM | SF | No | ARCHITECTURAL | 200 | A | A+ | ||||||||||||||||||||
| C3030999 | C3030999 - OTHER | SUBSYSTEM | No | |||||||||||||||||||||||||
| C3040 | C3040 - INTERIOR FINISH ASSEMBLIES | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| C3040999 | C3040999 - OTHER INTERIOR FINISH ASSEMBLIES | SUBSYSTEM | EA | No | ||||||||||||||||||||||||
| D10 | D10 - CONVEYING | MASTERSYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D1010 | D1010 - ELEVATORS AND LIFTS | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D1010110 | D1010110 - HYDRAULIC ELEVATORS | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D1010140 | D1010140 - TRACTION GEARED ELEVATORS | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D1010150 | D1010150 - TRACTION GEARLESS ELEVATORS | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D1010160 | D1010160 - CABLE DRUM ELEVATOR | SUBSYSTEM | EA | No | ARCHITECTURAL, STRUCTURAL, ELECTRICAL, MECHANICAL | 300 | A | A+ | ||||||||||||||||||||
| D1010200 | D1010200 - RACK & PINION AND SCREW COLUMN ELEVATORS | SUBSYSTEM | EA | No | ARCHITECTURAL, STRUCTURAL, ELECTRICAL, MECHANICAL | 300 | A | A+ | ||||||||||||||||||||
| D1010250 | D1010250 - ACCESSIBILITY LIFTS | SUBSYSTEM | EA | No | ARCHITECTURAL, STRUCTURAL, ELECTRICAL, MECHANICAL | 300 | A | A+ | ||||||||||||||||||||
| D1010300 | D1010300 - MATERIAL LIFTS | SUBSYSTEM | EA | No | ARCHITECTURAL, STRUCTURAL, ELECTRICAL, MECHANICAL | 300 | A | A+ | ||||||||||||||||||||
| D1010901 | D1010901 - LIFTS | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D1010999 | D1010999 - OTHER ELEVATORS | SUBSYSTEM | EA | No | ||||||||||||||||||||||||
| D1020 | D1020 - ESCALATORS AND MOVING WALKS | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D1020110 | D1020110 - ESCALATORS | SUBSYSTEM | EA | No | ARCHITECTURAL, MECHANICAL | 300 | A | A+ | ||||||||||||||||||||
| D1020210 | D1020210 - MOVING WALKS | SUBSYSTEM | LF | No | ARCHITECTURAL, MECHANICAL | 300 | A | A+ | ||||||||||||||||||||
| D1020999 | D1020999 - OTHER | SUBSYSTEM | EA | No | ||||||||||||||||||||||||
| D1090 | D1090 - OTHER CONVEYING SYSTEMS | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D1090901 | D1090901 - CONVEYORS | SUBSYSTEM | LF | No | ARCHITECTURAL, STRUCTURAL, ELECTRICAL | 300 | A | A+ | ||||||||||||||||||||
| D1090902 | D1090902 - CRANES AND HOISTS | SUBSYSTEM | EA | No | ARCHITECTURAL, STRUCTURAL, ELECTRICAL | 300 | A | A+ | ||||||||||||||||||||
| D1090903 | D1090903 - PNEUMATIC TUBE SYSTEM | SUBSYSTEM | LF | No | ARCHITECTURAL,ELECTRICAL, MECHANICAL | 300 | A | A+ | ||||||||||||||||||||
| D1090999 | D1090999 - OTHER | SUBSYSTEM | EA | No | ||||||||||||||||||||||||
| D20 | D20 - PLUMBING | MASTERSYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D2010 | D2010 - PLUMBING FIXTURES | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D2010110 | D2010110 - TOILET | SUBSYSTEM | EA | No | PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| D2010210 | D2010210 - URINAL | SUBSYSTEM | EA | No | PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| D2010310 | D2010310 - LAVATORY | SUBSYSTEM | EA | No | PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| D2010410 | D2010410 - SINK | SUBSYSTEM | EA | No | PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| D2010430 | D2010430 - LABORATORY SINK | SUBSYSTEM | EA | No | PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| D2010510 | D2010510 - BATHTUB | SUBSYSTEM | EA | No | PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| D2010610 | D2010610 - GROUP WASH FOUNTAIN | SUBSYSTEM | EA | No | PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| D2010710 | D2010710 - SHOWER | SUBSYSTEM | EA | No | PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| D2010810 | D2010810 - DRINKING FOUNTAIN | SUBSYSTEM | EA | No | PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| D2010820 | D2010820 - WATER COOLER | SUBSYSTEM | EA | No | PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| D2010901 | D2010901 - EMERGENCY SHOWER | SUBSYSTEM | EA | No | PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| D2010902 | D2010902 - EMERGENCY EYE WASH | SUBSYSTEM | EA | No | PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| D2010903 | D2010903 - BIDET | SUBSYSTEM | EA | No | PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| D2010999 | D2010999 - OTHER | SUBSYSTEM | EA | No | ||||||||||||||||||||||||
| D2020 | D2020 - DOMESTIC WATER DISTRIBUTION | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D2020210 | D2020210 - WATER HEATERS, RESIDENTIAL, ELEC | SUBSYSTEM | EA | No | PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| D2020220 | D2020220 - WATER HEATERS, RESIDENTIAL, GAS | SUBSYSTEM | EA | No | PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| D2020230 | D2020230 - WATER HEATERS, RESIDENTIAL, OIL | SUBSYSTEM | EA | No | PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| D2020240 | D2020240 - WATER HEATERS, COMMERCIAL, ELEC | SUBSYSTEM | EA | No | PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| D2020250 | D2020250 - WATER HEATERS, COMMERCIAL, GAS | SUBSYSTEM | EA | No | PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| D2020260 | D2020260 - WATER HEATERS, COMMERCIAL, OIL | SUBSYSTEM | EA | No | PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| D2020901 | D2020901 - BOOSTER PUMP | SUBSYSTEM | EA | No | PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| D2020902 | D2020902 - STORAGE TANK | SUBSYSTEM | EA | No | PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| D2020903 | D2020903 - BACKFLOW PREVENTER | SUBSYSTEM | EA | No | PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| D2020904 | D2020904 - HEAT TRANSFER PACKAGE | SUBSYSTEM | EA | No | PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| D2020905 | D2020905 - PIPING/FITTINGS | SUBSYSTEM | LF | No | PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| D2020906 | D2020906 - CIRCULATING PUMP | SUBSYSTEM | EA | No | PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| D2020999 | D2020999 - OTHER | SUBSYSTEM | No | |||||||||||||||||||||||||
| D2030 | D2030 - SANITARY WASTE | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D2030901 | D2030901 - SANITARY WASTE SEPARATOR | SUBSYSTEM | EA | No | PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| D2030902 | D2030902 - WASTE/VENT PIPING | SUBSYSTEM | LF | No | PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| D2030905 | D2030905 - SUMP PUMP | SUBSYSTEM | EA | No | PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| D2030999 | D2030999 - OTHER | SUBSYSTEM | EA | No | ||||||||||||||||||||||||
| D2040 | D2040 - RAIN WATER DRAINAGE | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D2040210 | D2040210 - ROOF DRAINS | SUBSYSTEM | LF | No | PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| D2040999 | D2040999 - OTHER | SUBSYSTEM | EA | No | ||||||||||||||||||||||||
| D2090 | D2090 - OTHER PLUMBING SYSTEMS | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D2090999 | D2090999 - OTHER | SUBSYSTEM | EA | No | ||||||||||||||||||||||||
| D30 | D30 - HVAC | MASTERSYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3010 | D3010 - ENERGY SUPPLY | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3010999 | D3010999 - OTHER | SUBSYSTEM | EA | No | ||||||||||||||||||||||||
| D3020 | D3020 - HEAT GENERATING SYSTEMS | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3020126 | D3020126 - BOILER, ELECTRIC, HOT WATER | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3020128 | D3020128 - BOILER, ELECTRIC, STEAM | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3020130 | D3020130 - BOILER CAST IRON HOT WATER GAS | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3020134 | D3020134 - BOILER, CAST IRON, STEAM, GAS | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3020136 | D3020136 - BOILER, CAST IRON HT WTR GAS/OIL | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3020138 | D3020138 - BOILER, CAST IRON, STEAM GAS/OIL | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3020311 | D3020311 - BOILER FUEL OIL PUMP | SUBSYSTEM | EA | No | MECHANICAL | 300 | A | A+ | ||||||||||||||||||||
| D3020901 | D3020901 - BOILER, CAST IRON, HT WTR, OIL | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3020902 | D3020902 - BOILER, CAST IRON, STEAM, OIL | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3020903 | D3020903 - BOILER, SOLID FUEL | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3020904 | D3020904 - BOILER FEEDWATER TANK | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3020905 | D3020905 - FURNACE | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3020906 | D3020906 - EXPANSION TANK | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3020999 | D3020999 - OTHER | SUBSYSTEM | EA | No | ||||||||||||||||||||||||
| D3020311 | D3020311 - BOILER FUEL OIL PUMP | SUBSYSTEM | EA | No | ||||||||||||||||||||||||
| D3030 | D3030 - COOLING GENERATING SYSTEMS | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3030120 | D3030120 - CHILLER, SCROLL, AIR COOLED | SUBSYSTEM | EA | No | MECHANICAL | 300 | A | A+ | ||||||||||||||||||||
| D3030125 | D3030125 - CHILLER, SCROLL, WATER COOLED | SUBSYSTEM | EA | No | MECHANICAL | 300 | A | A+ | ||||||||||||||||||||
| D3030130 | D3030130 - CHILLER, RECIP, WATER COOLED | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3030135 | D3030135 - CHILLER, RECIP, AIR COOLED | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3030140 | D3030140 - CHILLER, CENTRIFUGAL, WTR COOLED | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3030145 | D3030145 - CHILLER, GAS ABSO, WTR COOLED | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3030150 | D3030150 - CHILLER, STEAM ABSO, WTR COOLED | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3030160 | D3030160 - CHILLER, SCREW, AIR COOLED | SUBSYSTEM | EA | No | MECHANICAL | 300 | A | A+ | ||||||||||||||||||||
| D3030165 | D3030165 - CHILLER, SCREW, WATER COOLED | SUBSYSTEM | EA | No | MECHANICAL | 300 | A | A+ | ||||||||||||||||||||
| D3030221 | D3030221 - CONDENSING UNIT, AIR COOLED | SUBSYSTEM | EA | No | MECHANICAL | 300 | A | A+ | ||||||||||||||||||||
| D3030222 | D3030222 - CONDENSING UNIT, WATER COOLED | SUBSYSTEM | EA | No | MECHANICAL | 300 | A | A+ | ||||||||||||||||||||
| D3030223 | D3030223 - SPLIT DUCTLESS UNIT, OUTDOOR UNIT | SUBSYSTEM | EA | No | MECHANICAL | 300 | A | A+ | ||||||||||||||||||||
| D3030223 | D3030223 - SPLIT DUCTLESS HEAT PUMP , OUTDOOR UNIT | SUBSYSTEM | EA | No | MECHANICAL | 300 | A | A+ | ||||||||||||||||||||
| D3030224 | D3030224 - SPLIT SYSTEM HEAT PUMP , OUTDOOR UNIT | SUBSYSTEM | EA | No | MECHANICAL | 300 | A | A+ | ||||||||||||||||||||
| D3030310 | D3030310 - COOLING TOWER, GALVANIZED | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3030320 | D3030320 - COOLING TOWER, FIBERGLASS | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3030330 | D3030330 - COOLING TOWER, STAINLESS STEEL | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3030901 | D3030901 - CONDENSER, DX, AIR COOLED | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3030902 | D3030902 - CONDENSER, DX, EVAPORATIVE | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3030903 | D3030903 - PACKAGED DX REFRIGERANT SYSTEM | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3030999 | D3030999 - OTHER | SUBSYSTEM | EA | No | ||||||||||||||||||||||||
| D3040 | D3040 - DISTRIBUTION SYSTEMS | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3040106 | D3040106 - AIR HANDLING UNIT, FIELD FAB | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3040110 | D3040110 - AIR HANDLING UNIT, CENTRAL STA | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3040114 | D3040114 - AIR HANDLING UNIT, ROOFTOP | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3040118 | D3040118 - FAN COIL A/C, CAB MNT, TWO PIPE | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3040122 | D3040122 - FAN COIL A/C, CAB MNT, FOUR PIPE | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3040124 | D3040124 - FAN COIL A/C, DUCT MOUNT, 2 PIPE | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3040128 | D3040128 - FAN COIL A/C, DUCT MOUNT, 4 PIPE | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3040132 | D3040132 - VAV TERMINAL | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3040136 | D3040136 - VAV TERMINAL, FAN POWERED | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3040220 | D3040220 - FAN SYSTEM, CENTRIFUGAL IN-LINE | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3040230 | D3040230 - FAN SYSTEM, UTILITY SET | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3040240 | D3040240 - FAN SYSTEM, ROOF EXHAUST | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3040250 | D3040250 - COMM/IND VACUUM DUST COLLECTION | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3040260 | D3040260 - KITCHEN EXHAUST/MAKE-UP AIR | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3040312 | D3040312 - CONDENSATE RETURN PUMP | SUBSYSTEM | EA | No | MECHANICAL | 300 | A | A+ | ||||||||||||||||||||
| D3040313 | D3040313 - CONDENSATE RETURN PUMP, DUPLEX | SUBSYSTEM | EA | No | MECHANICAL | 300 | A | A+ | ||||||||||||||||||||
| D3040330 | D3040330 - CIRCULATING PUMP, END SUCTION | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3040340 | D3040340 - CIRCULATING PUMP, DOUBLE SUCTION | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3040610 | D3040610 - HEAT EXCHANGER, PLATE TYPE | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3040620 | D3040620 - HEAT EXCHANGER, SHELL TUBE | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3040901 | D3040901 - DEHUMIDIFIER | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3040902 | D3040902 - HUMIDIFIER | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3040903 | D3040903 - FAN COIL A/C, DX | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3040999 | D3040999 - OTHER | SUBSYSTEM | EA | No | ||||||||||||||||||||||||
| D3040904 | D3040904 - SPLIT DUCTLESS SYSTEM, INDOOR UNIT | SUBSYSTEM | EA | No | MECHANICAL | 300 | A | A+ | ||||||||||||||||||||
| D3040905 | D3040905 - SPLIT SYSTEM HEAT PUMP, INDOOR UNIT | SUBSYSTEM | EA | No | MECHANICAL | 300 | A | A+ | ||||||||||||||||||||
| D3050 | D3050 - TERMINAL & PACKAGE UNITS | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3050120 | D3050120 - UNIT HEATERS, GAS | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3050130 | D3050130 - UNIT HEATERS, HYDRONIC | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3050170 | D3050170 - SPLIT SYSTEMS AIR COOLED CONDENSE UNIT | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3050175 | D3050175 - ROOFTOP A/C | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3050176 | D3050176 - ROOFTOP AIR CONDITIONER, ELECTRIC HEAT | SUBSYSTEM | EA | No | MECHANICAL | 300 | A | A+ | ||||||||||||||||||||
| D3050178 | D3050178 - ROOFTOP AIR CONDITIONER, HOT WATER HEAT | SUBSYSTEM | EA | No | MECHANICAL | 300 | A | A+ | ||||||||||||||||||||
| D3050179 | D3050179 - ROOFTOP AIR CONDITIONER, STEAM HEAT | SUBSYSTEM | EA | No | MECHANICAL | 300 | A | A+ | ||||||||||||||||||||
| D3050185 | D3050185 - COMPUTER ROOM COOLING UNITS | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3050201 | D3050201 - PKG A/C, AIR COOLED, ELEC HEAT | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3050203 | D3050203 - PKG A/C, AIR COOLED, HW HEAT | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3050210 | D3050210 - PKG A/C, WATER COOLED, ELEC HEAT | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3050220 | D3050220 - PKG A/C, WATER COOLED, HW HEAT | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3050230 | D3050230 - HEAT PUMP, WTR SOURCE, CENT STA | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3050235 | D3050235 - HEAT PUMP, WATER SOURCE, CONSOLE | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3050240 | D3050240 - HEAT PUMP, DUCT MNT, HORIZONTAL | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3050245 | D3050245 - HEAT PUMP, AIR/AIR, ROOF TOP | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3050255 | D3050255 - THRU-WALL A/C UNIT | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3050260 | D3050260 - THRU-WALL HEAT PUMP | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3050330 | D3050330 - PACKAGE TERMINAL AIR CONDITIONER (PTAC) | SUBSYSTEM | EA | No | MECHANICAL | 300 | A | A+ | ||||||||||||||||||||
| D3050340 | D3050340 - PACKAGE TERMINAL HEAT PUMP (PTHP) | SUBSYSTEM | EA | No | MECHANICAL | 300 | A | A+ | ||||||||||||||||||||
| D3050530 | D3050530 - BASEBOARD HEATING | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3050901 | D3050901 - UNIT HEATERS, ELECTRIC | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3050902 | D3050902 - UNIT HEATER, INFRARED | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3050904 | D3050904 - SMOKE VENTS | SUBSYSTEM | EA | No | MECHANICAL | 300 | A | A+ | ||||||||||||||||||||
| D3050905 | D3050905 - HYDRONIC HEATING - FIN TUBE | SUBSYSTEM | LF | No | MECHANICAL | 300 | A | A+ | ||||||||||||||||||||
| D3050999 | D3050999 - OTHER | SUBSYSTEM | EA | No | ||||||||||||||||||||||||
| D3060 | D3060 - CONTROLS & INSTRUMENTATION | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3060901 | D3060901 - HVAC CONTROLS, ELECTRIC, DIGITAL | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3060902 | D3060902 - HVAC CONTROLS, PNUEMATIC | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3060903 | D3060903 - AIR COMPRESSOR | SUBSYSTEM | EA | No | MECHANICAL | 300 | A | A+ | ||||||||||||||||||||
| D3060904 | D3060904 - AIR DRYER | SUBSYSTEM | EA | No | MECHANICAL | 300 | A | A+ | ||||||||||||||||||||
| D3060905 | D3060905 - DIRECT DIGITAL CONTROL (DDC) SYSTEM | SUBSYSTEM | EA | No | MECHANICAL | 300 | A | A+ | ||||||||||||||||||||
| D3060999 | D3060999 - OTHER | SUBSYSTEM | EA | No | ||||||||||||||||||||||||
| D3090 | D3090 - OTHER HVAC SYSTEMS & EQUIPMENT | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3090220 | D3090220 - ENERGY RECOVERY WHEEL | SUBSYSTEM | EA | No | MECHANICAL | 300 | A | A+ | ||||||||||||||||||||
| D3090310 | D3090310 - FUME HOOD EXHAUST SYSTEM | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3090320 | D3090320 - GARAGE EXHAUST SYSTEMS | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3090901 | D3090901 - INDUSTRIAL EXHAUST SYSTEM | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3090902 | D3090902 - CHEMICAL FEEDWATER | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D3090903 | D3090903 - AIR CURTAIN | SUBSYSTEM | LF | No | MECHANICAL | 300 | A | A+ | ||||||||||||||||||||
| D3090999 | D3090999 - OTHER | SUBSYSTEM | LF | No | ||||||||||||||||||||||||
| D40 | D40 - FIRE PROTECTION | MASTERSYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D4010 | D4010 - SPRINKLERS | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D4010310 | D4010310 - DRY PIPE SYSTEMS | SUBSYSTEM | SF | No | FIRE PROTECTION | 300 | A | A+ | ||||||||||||||||||||
| D4010350 | D4010350 - PREACTION SYSTEMS | SUBSYSTEM | SF | No | FIRE PROTECTION | 300 | A | A+ | ||||||||||||||||||||
| D4010370 | D4010370 - DELUGE SYSTEMS | SUBSYSTEM | SF | No | FIRE PROTECTION | 300 | A | A+ | ||||||||||||||||||||
| D4010390 | D4010390 - FIRECYCLE SYSTEMS | SUBSYSTEM | SF | No | FIRE PROTECTION | 300 | A | A+ | ||||||||||||||||||||
| D4010410 | D4010410 - WET PIPE SYSTEMS | SUBSYSTEM | SF | No | FIRE PROTECTION | 300 | A | A+ | ||||||||||||||||||||
| D4010905 | D4010905 - FIRE PUMP, ELECTRIC MOTOR DRIVEN | SUBSYSTEM | EA | No | FIRE PROTECTION | 300 | A | A+ | ||||||||||||||||||||
| D4010906 | D4010906 - FIRE PUMP, ENGINE DRIVIEN | SUBSYSTEM | EA | No | FIRE PROTECTION | 300 | A | A+ | ||||||||||||||||||||
| D4010907 | D4010907 - JOCKEY PUMP | SUBSYSTEM | EA | No | FIRE PROTECTION | 300 | A | A+ | ||||||||||||||||||||
| D4010908 | D4010908 - AIR COMPRESSOR | SUBSYSTEM | EA | No | FIRE PROTECTION | 300 | A | A+ | ||||||||||||||||||||
| D4010999 | D4010999 - OTHER | SUBSYSTEM | EA | No | ||||||||||||||||||||||||
| D4020 | D4020 - STANDPIPES | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D4020310 | D4020310 - RISER | SUBSYSTEM | FLOOR | No | FIRE PROTECTION | 300 | A | A+ | ||||||||||||||||||||
| D4020999 | D4020999 - OTHER | EA | No | |||||||||||||||||||||||||
| D4030 | D4030 - FIRE PROTECTION SPECIALTIES | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D4030999 | D4030999 - OTHER | No | ||||||||||||||||||||||||||
| D4090 | D4090 - OTHER FIRE PROTECTION SYSTEMS | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D4090901 | D4090901 - CARBON DIOXIDE EXTINGUISHING SYS | SUBSYSTEM | EA | No | FIRE PROTECTION | 300 | A | A+ | ||||||||||||||||||||
| D4090902 | D4090902 - HOOD FIRE PROTECTION | SUBSYSTEM | EA | No | FIRE PROTECTION | 300 | A | A+ | ||||||||||||||||||||
| D4090903 | D4090903 - BACKFLOW PREVENTER | SUBSYSTEM | EA | No | FIRE PROTECTION | 300 | A | A+ | ||||||||||||||||||||
| D4090904 | D4090904 - FIRE PUMPS | SUBSYSTEM | EA | No | FIRE PROTECTION | 300 | A | A+ | ||||||||||||||||||||
| D4090920 | D4090920 - CLEAN AGENT EXTINGUISHING SYSTEM | SUBSYSTEM | SF | No | FIRE PROTECTION | 300 | A | A+ | ||||||||||||||||||||
| D4090999 | D4090999 - OTHER | SUBSYSTEM | EA | No | ||||||||||||||||||||||||
| D50 | D50 - ELECTRICAL | MASTERSYSTEM | ● | Yes | ● | ● | ● | ● | ● | |||||||||||||||||||
| D5010 | D5010 - ELECTRICAL SERVICE & DISTRIBUTION | SYSTEM | ● | Yes | ● | ● | ● | ● | ● | |||||||||||||||||||
| D5010120 | D5010120 - ELECTRICAL SERVICE | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D5010240 | D5010240 - SWITCHGEAR | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D5010901 | D5010901 - TRANSFER SWITCH | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D5010902 | D5010902 - TRANSFORMER | SUBSYSTEM | EA | Yes | ● | ● | ● | ● | ● | |||||||||||||||||||
| D5010903 | D5010903 - MOTOR CONTROL CENTER | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D5010905 | D5010905 - CAPACITOR BANK | SUBSYSTEM | EA | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| D5010906 | D5010906 - PANELBOARDS | SUBSYSTEM | EA | Yes | ● | ● | ● | ● | ● | |||||||||||||||||||
| D5010999 | D5010999 - OTHER | SUBSYSTEM | EA | Yes | ||||||||||||||||||||||||
| D5020 | D5020 - LIGHTING & BRANCH WIRING | SYSTEM | ● | Yes | ● | ● | ● | ● | ● | |||||||||||||||||||
| D5020120 | D5020120 - ELECTRICAL DISTRIBUTION | SUBSYSTEM | SF | Yes | ELECTRICAL | 200 | A | A+ | ||||||||||||||||||||
| D5020248 | D5020248 - INTERIOR LIGHTING, FLUORECENT | SUBSYSTEM | EA | No | ELECTRICAL | 300 | A | A+ | ||||||||||||||||||||
| D5020250 | D5020250 - INTERIOR LIGHTING, INCANDESCENT | SUBSYSTEM | EA | No | ELECTRICAL | 300 | A | A+ | ||||||||||||||||||||
| D5020252 | D5020252 - INTERIOR LIGHTING, HIGH INT | SUBSYSTEM | EA | No | ELECTRICAL | 300 | A | A+ | ||||||||||||||||||||
| D5020901 | D5020901 - EXIT LIGHTING | SUBSYSTEM | EA | No | ELECTRICAL | 300 | A | A+ | ||||||||||||||||||||
| D5020902 | D5020902 - EXPLOSION PROOF LIGHTING | SUBSYSTEM | EA | No | ELECTRICAL | 300 | A | A+ | ||||||||||||||||||||
| D5020903 | D5020903 - EXTERIOR LIGHTING | SUBSYSTEM | EA | Yes | ELECTRICAL | 300 | A | A+ | ||||||||||||||||||||
| D5020999 | D020999 - OTHER | SUBSYSTEM | EA | Yes | ||||||||||||||||||||||||
| D5030 | D5030 - COMMUNICATION AND SECURITY | SYSTEM | ● | Yes | ● | ● | ● | ● | ● | |||||||||||||||||||
| D5030910 | D5030910 - COMMUNICATION/ALARM SYSTEMS | SUBSYSTEM | EA | Yes | ● | |||||||||||||||||||||||
| D5030911 | D5030911 - FIRE ALARM CONTROL PANEL & ALARM SYSTEM | SUBSYSTEM | EA | No | ELECTRICAL | 200 | A | A+ | ||||||||||||||||||||
| D5030930 | D5030930 - MASTER BOX | SUBSYSTEM | EA | No | ELECTRICAL | 200 | A | A+ | ||||||||||||||||||||
| D5030999 | D5030999-OTHER | SUBSYSTEM | EA | No | ||||||||||||||||||||||||
| D5090 | D5090 - OTHER ELECTRICAL SYSTEMS | SYSTEM | ● | Yes | ● | ● | ● | ● | ● | |||||||||||||||||||
| D5090210 | D5090210 - GENERATORS | SUBSYSTEM | EA | No | ● | ● | ● | |||||||||||||||||||||
| D5090901 | D5090901 - EMERGENCY LIGHTING | SUBSYSTEM | EA | Yes | ● | ● | ● | |||||||||||||||||||||
| D5090902 | D5090902 - LIGHTNING PROTECTION (ARRESTERS) | SUBSYSTEM | EA | No | ELECTRICAL | 200 | A | A+ | ||||||||||||||||||||
| D5090903 | D5090903 - GROUNDING SYSTEM | SUBSYSTEM | EA | Yes | ELECTRICAL | 200 | A | A+ | ||||||||||||||||||||
| D5090904 | D5090904 - UNINTERUPTIBLE POWER SUPPLY | SUBSYSTEM | EA | No | ● | ● | ● | |||||||||||||||||||||
| D5090999 | D5090999 - OTHER | SUBSYSTEM | EA | Yes | ||||||||||||||||||||||||
| E10 | E10 - EQUIPMENT | MASTERSYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| E1010 | E1010 - COMMERCIAL EQUIPMENT | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| E1010220 | E1010220 - CONDENSING UNIT, AIR COOLED | SUBSYSTEM | EA | No | ARCHITECTURAL | 200 | A | A+ | ||||||||||||||||||||
| E1010901 | E1010901 - CONDENSER, DX, AIR COOLED | SUBSYSTEM | EA | No | ARCHITECTURAL | 200 | A | A+ | ||||||||||||||||||||
| E1010910 | E1010910 - REFRIGERATOR/FREEZER WALK-IN BOX | SUBSYSTEM | EA | No | ARCHITECTURAL | 200 | A | A+ | ||||||||||||||||||||
| E1010999 | E1010999 - OTHER COMMERCIAL EQUIPMENT | SUBSYSTEM | EA | No | ARCHITECTURAL | 200 | A | A+ | ||||||||||||||||||||
| E1020 | E1020 - INSTITUTIONAL EQUIPMENT | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| E1020999 | E1020999 - OTHER INSTITUTIONAL EQUIPMENT | SUBSYSTEM | EA | No | ARCHITECTURAL | 200 | A | A+ | ||||||||||||||||||||
| E1030 | E1030 - VEHICULAR EQUIPMENT | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| E1030110 | E1030110 - VEHICULAR SERVICE EQUIPMENT | SUBSYSTEM | EA | No | ARCHITECTURAL | 200 | A | A+ | ||||||||||||||||||||
| E1030111 | E1030111 - AIR COMPRESSOR | SUBSYSTEM | EA | No | ARCHITECTURAL | 200 | A | A+ | ||||||||||||||||||||
| E1030112 | E1030112 - AIR DRYER | SUBSYSTEM | EA | No | ARCHITECTURAL | 200 | A | A+ | ||||||||||||||||||||
| E1030310 | E1030310 - LOADING DOCK EQUIPMENT | SUBSYSTEM | EA | No | ARCHITECTURAL | 200 | A | A+ | ||||||||||||||||||||
| E1030999 | E1030999 - OTHER | SUBSYSTEM | EA | No | ARCHITECTURAL | 200 | A | A+ | ||||||||||||||||||||
| E1040 | E1040 - INDUSTRIAL PROCESS EQUIPMENT | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| E1040999 | E1040999 - OTHER INDUSTRIAL PROCESS EQUIPMENT | SUBSYSTEM | EA | No | ARCHITECTURAL | 200 | A | A+ | ||||||||||||||||||||
| E1090 | E1090 - OTHER EQUIPMENT | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| E1090999 | E1090999 - OTHER EQUIPMENT | SUBSYSTEM | EA | No | ARCHITECTURAL | 200 | A | A+ | ||||||||||||||||||||
| E20 | E20 - FURNISHINGS | MASTERSYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| E2010 | E2010 - FIXED FURNISHINGS | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| E201099 | E201099 - OTHER FIXED FURNISHINGS | SUBSYSTEM | EA | No | ARCHITECTURAL | 200 | A | A+ | ||||||||||||||||||||
| E2020 | E2020 - MOVEABLE FURNISHINGS | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| E202002 | E202002 - MODULAR PREFABRICATED FURNITURE | SUBSYSTEM | EA | No | INTERIORS | 200 | C | - | ||||||||||||||||||||
| E202099 | E202099 - OTHER MOVEABLE FURNISHINGS | SUBSYSTEM | EA | No | INTERIORS | 200 | C | - | ||||||||||||||||||||
| F10 | F10 - SPECIAL CONSTRUCTION | MASTERSYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| F1010 | F1010 - SPECIAL STRUCTURES | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| F101001 | F101001 - PRE-ENGINEERED STRUCTURES | SUBSYSTEM | SF | No | ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| F101001.01 | F101001.01 - K-SPAN BUILT STRUCTURES | SUBSYSTEM | SF | No | ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| F101003 | F101003 - AIR SUPPORTED STRUCTURES | SUBSYSTEM | EA | No | ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| F101099.01 | F101099.01 - PAINT BOOTH | SUBSYSTEM | EA | No | ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| F101099.02 | F101099.02 - PORTABLE OFFICE UNITS | SUBSYSTEM | EA | No | ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| F1020 | F1020 - INTEGRATED CONSTRUCTION | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| F102001 | F102001 - SPECIAL PURPOSE ROOMS | SUBSYSTEM | SF | No | ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| F102002 | F102002 - INTEGRATED ASSEMBLIES | SUBSYSTEM | SF | No | ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| F102099 | F102099 - OTHER INTERGRATED CONSTRUCTION | SUBSYSTEM | SF | No | ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| F1030 | F1030 - SPECIAL CONSTRUCTION SYSTEMS | SYSTEM | ● | Yes | ● | ● | ● | ● | ● | |||||||||||||||||||
| F103001 | F103001 - VAULTS | SUBSYSTEM | SF | Yes | ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| F103002 | F103002 - SOUND VIBRATION AND SEISMIC CONSTRUCTION | SUBSYSTEM | SF | No | ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| F103003 | F103003 - RADIATION PROTECTION | SUBSYSTEM | SF | No | ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| F103099 | F103099 - OTHER SPECIAL CONSTRUCTION SYSTEMS | SUBSYSTEM | SF | No | ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| F1040 | F1040 - SPECIAL FACILITIES | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| F104001 | F104001 - INTERIOR SWIMMING POOLS | SUBSYSTEM | SF | No | ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| F104002 | F104002 - LIQUID AND GAS STORAGE TANKS | SUBSYSTEM | EA | No | ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| F104003 | F104003 - KENNELS AND ANIMAL SHELTERS | SUBSYSTEM | SF | No | ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| F104004 | F104004 - SITE CONSTRUCTED INCINERATORS | SUBSYSTEM | EA | No | ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| F104005 | F104005 - ICE RINKS | SUBSYSTEM | SF | No | ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| F104099 | F104099 - OTHER SPECIAL FACILITIES | SUBSYSTEM | SF | No | ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| F1050 | F1050 - SPECIAL CONTROLS AND INSTRUMENTATION | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| F105001 | F105001 - RECORDING INSTRUMENTATION | SUBSYSTEM | EA | No | ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING | 300 | A | A+ | ||||||||||||||||||||
| F105002 | F105002 - BUILDING AUTOMATION SYSTEMS | SUBSYSTEM | EA | No | ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING, FIRE PROTECTION | 300 | A | A+ | ||||||||||||||||||||
| F20 | F20 - SELECTIVE BUILDING DEMOLITION | MASTERSYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| F2010 | F2010 - BUILDING ELEMENTS DEMOLITION | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| F201001 | F201001 - SUBSTRUCTURE AND SUPERSTRUCTURE | SUBSYSTEM | LS | No | STRUCTURAL | 200 | C | C+ | ||||||||||||||||||||
| F201002 | F201002 - EXTERIOR ENCLOSURE | SUBSYSTEM | LS | No | ARCHITECTURAL | 200 | C | C+ | ||||||||||||||||||||
| F201003 | F201003 - ROOFING | SUBSYSTEM | LS | No | ARCHITECTURAL | 200 | C | C+ | ||||||||||||||||||||
| F201004 | F201004 - INTERIOR CONSTRUCTION AND FINISHES | SUBSYSTEM | LS | No | ARCHITECTURAL | 200 | C | C+ | ||||||||||||||||||||
| F201005 | F201005 - CONVEYING SYSTEMS | SUBSYSTEM | LS | No | ARCHITECTURAL | 200 | C | C+ | ||||||||||||||||||||
| F201006 | F201006 - MECHANICAL SYSTEMS | SUBSYSTEM | LS | No | MECHANICAL | 200 | C | C+ | ||||||||||||||||||||
| F201007 | F201007 - ELECTRICAL SYSTEMS | SUBSYSTEM | LS | No | ELECTRICAL | 200 | C | C+ | ||||||||||||||||||||
| F201008 | F201008 - EQUIPMENT AND FURNISHINGS | SUBSYSTEM | LS | No | ARCHITECTURAL, INTERIORS | 200 | C | C+ | ||||||||||||||||||||
| F2020 | F2020 - HAZARDOUS COMPONENTS & SUPERSTRUCTURE | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| F202001 | F202001 - SUBSTRUCTURE AND SUPERSTUCUTRE | SUBSYSTEM | LS | No | STRUCTURAL | 200 | C | C+ | ||||||||||||||||||||
| F202002 | F202002 - EXTERIOR ENCLOSURE | SUBSYSTEM | LS | No | ARCHITECTURAL | 200 | C | C+ | ||||||||||||||||||||
| F202003 | F202003 - ROOFING | SUBSYSTEM | LS | No | ARCHITECTURAL | 200 | C | C+ | ||||||||||||||||||||
| F202004 | F202004 - INTERIOR CONSTRUCTION AND FINISHES | SUBSYSTEM | LS | No | ARCHITECTURAL | 200 | C | C+ | ||||||||||||||||||||
| F202005 | F202005 - CONVEYING SYSTEMS | SUBSYSTEM | LS | No | ARCHITECTURAL | 200 | C | C+ | ||||||||||||||||||||
| F202006 | F202006 - MECHANICAL SYSTEMS | SUBSYSTEM | LS | No | MECHANICAL | 200 | C | C+ | ||||||||||||||||||||
| F202007 | F202007 - ELECTRICAL SYSTEMS | SUBSYSTEM | LS | No | ELECTRICAL | 200 | C | C+ | ||||||||||||||||||||
| F202008 | F202008 - EQUIPMENT AND FURNISHINGS | SUBSYSTEM | LS | No | ARCHITECTURAL, INTERIORS | 200 | C | C+ | ||||||||||||||||||||
| F202009 | F202009 - OTHER HAZARDOUS SELECTIVE BUILDING DEMO | SUBSYSTEM | LS | No | ARCHITECTURAL, INTERIORS | 200 | C | C+ | ||||||||||||||||||||
| F30 | F30 - BUILDING SERVICES | MASTERSYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| F3010 | F3010 - JANITORIAL SERVICES | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| F301010 | F301010 - JANITORIAL SERVICES | SUBSYSTEM | SF | No | N/A | - | - | - | ||||||||||||||||||||
| G20 | G20 - SITE IMPROVEMENTS | MASTERSYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| G2010 | G2010 - PAVEMENTS | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| G201002.01 | G201002.01 - CURBS AND GUTTERS | SUBSYSTEM | CY | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G201002.02 | G201002.02 - DRAINS | SUBSYSTEM | EA | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G201003.01 | G201003.01 - FLEXIBLE ASPHALT PAVEMENTS | SUBSYSTEM | SF | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G201003.02 | G201003.02 - RIGID CONCRETE PAVEMENTS | SUBSYSTEM | SF | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G201004 | G201004 - MARKINGS AND SIGNAGE | SUBSYSTEM | EA | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G201005 | G201005 - GUARDRAILS AND BARRIERS | SUBSYSTEM | EA | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G201005.01 | G201005.01 - VEHICLE CRASH BARRIER | SUBSYSTEM | EA | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G201005.02 | G201005.02 - VEHICLE CRASH BEAM | SUBSYSTEM | EA | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G201005.03 | G201005.03 - VEHICLE RETRACTABLE BOLLARDS | SUBSYSTEM | EA | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G201005.04 | G201005.04 - VEHICLE TRAFFIC ARM | SUBSYSTEM | EA | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G201005.05 | G201005.05 - VEHICLE TRAFFIC SPIKES | SUBSYSTEM | EA | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G201099.01 | G201099.01 - COMPOSITE | SUBSYSTEM | SF | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G201099.02 | G201099.02 - PAVERS | SUBSYSTEM | SF | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G201099.03 | G201099.03 - UNIMPROVED/GRAVEL | SUBSYSTEM | CY | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G2020 | G2020 - A PARKING LOT /PARKING AREA PAVEMENT | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| G202001 | G202001 - PARKING LOT BASES AND SUBBASES | SUBSYSTEM | EA | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G202005.01 | G202005.01 - GUARD RAIL AND POSTS | SUBSYSTEM | LF | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G202005.02 | G202005.02 - WHEEL STOPS | SUBSYSTEM | EA | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G2020061 | G2020061 - ASHPALT RESURFACING | SUBSYSTEM | EA | No | CIVIL | 100 | B | B+ | ||||||||||||||||||||
| G2020062 | G2020062 - CONCRETE RESURFACING | SUBSYSTEM | EA | No | CIVIL | 100 | B | B+ | ||||||||||||||||||||
| G202007 | G202007 - PARKING METERS | SUBSYSTEM | EA | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G202099 | G202099 - OTHER A PARKING LOT/PARKING AREA PAVEMENT | SUBSYSTEM | EA | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G2030 | G2030 - PEDESTRIAN PAVING | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| G203003.01 | G203003.01 - ASPHALT PEDESTRIAN PAVING | SUBSYSTEM | SF | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G203003.02 | G203003.02 - CONCRETE PEDESTRIAN PAVING | SUBSYSTEM | SF | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G203003.03 | G203003.03 - PAVERS PEDESTRIAN PAVING | SUBSYSTEM | SF | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G2040 | G2040 - SITE IMPROVEMENTS & AMMENITIES | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| G204001.01 | G204001.01 - FENCES AND GATES | SUBSYSTEM | LF | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G204001.02 | G204001.02 - FENCES - CHAIN LINK | SUBSYSTEM | LF | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G204001.03 | G204001.03 - FENCES - MISCELLANEOUS METAL | SUBSYSTEM | LF | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G204002 | G204002 - RETAINING WALLS | SUBSYSTEM | LF | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G204005 | G204005 - SIGNAGE | SUBSYSTEM | EA | No | CIVIL | 200 | B | B+ | ||||||||||||||||||||
| G204006.01 | G204006.01 - FOUNTAINS, POOLS AND WATERCOURSES | SUBSYSTEM | EA | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G204006.02 | G204006.02 - FOUNTAINS | SUBSYSTEM | EA | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G204008.01 | G204008.01 - TERRACE AND PERIMETER WALLS | SUBSYSTEM | CY | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G204008.02 | G204008.02 - STONE WALL | SUBSYSTEM | LF | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G204008.03 | G204008.03 - FREE STANDING BRICK WALL | SUBSYSTEM | SF | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G204009 | G204009 - FLAG POLES | SUBSYSTEM | EA | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G204099 | G204099 - TRUCK SCALES | SUBSYSTEM | EA | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G204099.01 | G204099.01 - SITE FURNISHINGS | SUBSYSTEM | EA | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G204099.02 | G204099.02 - SITE SEATING | SUBSYSTEM | EA | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G204099.03 | G204099.03 - HANDRAIL - PIPE RAILINGS | SUBSYSTEM | LF | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G204099.04 | G204099.04 - CIGARETTE RECEPTACLE | SUBSYSTEM | EA | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G204099.05 | G204099.05 - GUARD RAILS AND POSTS | SUBSYSTEM | LF | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G204099.06 | G204099.06 - TRASH CANS | SUBSYSTEM | EA | No | CIVIL | 200 | B | B+ | ||||||||||||||||||||
| G204099.07 | G204099.07 - MAILBOXES | SUBSYSTEM | EA | No | CIVIL | 200 | B | B+ | ||||||||||||||||||||
| G204099.08 | G204099.08 - TURNSTILES | SUBSYSTEM | EA | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G204099.09 | G204099.09 - OUTDOOR COVERING | SUBSYSTEM | SF | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G2050 | G2050 - LANDSCAPING | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| G205004 | G205004 - LAWNS AND GRASSES | SUBSYSTEM | SF | No | LANDSCAPE ARCHITECTURE, CIVIL | 200 | B | B+ | ||||||||||||||||||||
| G205005 | G205005 - EXTERIOR PLANTS | SUBSYSTEM | EA | No | LANDSCAPE ARCHITECTURE, CIVIL | 200 | B | B+ | ||||||||||||||||||||
| G205006 | G205006 - PLANTERS | SUBSYSTEM | EA | No | LANDSCAPE ARCHITECTURE, CIVIL | 200 | B | B+ | ||||||||||||||||||||
| G205007.01 | G205007.01 - IRRIGATION PIPING | SUBSYSTEM | SF | No | LANDSCAPE ARCHITECTURE, CIVIL | 200 | B | B+ | ||||||||||||||||||||
| G205007.02 | G205007.02 - IRRIGATION BACKFLOW PREVENTION | SUBSYSTEM | EA | No | LANDSCAPE ARCHITECTURE, CIVIL | 200 | B | B+ | ||||||||||||||||||||
| G205007.03 | G205007.03 - IRRIGATION CONTROLS | SUBSYSTEM | EA | No | LANDSCAPE ARCHITECTURE, CIVIL | 200 | B | B+ | ||||||||||||||||||||
| G205099 | G205099 - LANDSCAPING | SUBSYSTEM | SF | No | LANDSCAPE ARCHITECTURE, CIVIL | 200 | B | B+ | ||||||||||||||||||||
| G2060 | G2060 - A ROAD/ STREET PAVEMENT | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| G206001 | G206001 - ROAD BASES AND SUBBASES | SUBSYSTEM | EA | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G206099 | G206099 - OTHER A ROAD/STREET PAVEMENT | SUBSYSTEM | EA | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G2099 | G2099 - OTHER SITE IMPROVEMENTS | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| G209999 | G209999 - OTHER SITE IMPROVEMENTS | SUBSYSTEM | EA | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G90 | G90 - OTHER SITE CONSTRUCTION | MASTERSYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| G9010 | G9010 - SERVICE AND PEDESTRIAN TUNNELS | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| G901001.01 | G901001.01 - SERVICE TUNNELS | SUBSYSTEM | LF | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G901001.04 | G901001.04 - INITIAL TUNNEL SUPPORT SYSTEMS | SUBSYSTEM | EA | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G901001.05 | G901001.05 - BORING OR JACKING CONDUITS | SUBSYSTEM | EA | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G901001.06 | G901001.06 - MICROTUNNELING | SUBSYSTEM | LF | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G901001.07 | G901001.07 - TRENCH BOXES | SUBSYSTEM | CY | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G901001.08 | G901001.08 - PEDESTRIAN TUNNELS | SUBSYSTEM | LF | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G9090 | G9090 - OTHER SITE SYSTEMS & EQUIPMENT | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| G909001.01 | G909001.01 - VEHICULAR BRIDGES | SUBSYSTEM | EA | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G909001.02 | G909001.02 - PREFABRICATED BRIDGES | SUBSYSTEM | EA | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G909002 | G909002 - RAILROAD TRACKS AND BEDS | SUBSYSTEM | EA | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G909002.01 | G909002.01 - RAILROAD TRACK | SUBSYSTEM | LF | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G909002.02 | G909002.02 - RAILROAD GRADE CROSSINGS | SUBSYSTEM | EA | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G909002.03 | G909002.03 - RAILROAD TRAIN SCALES | SUBSYSTEM | EA | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G909003 | G909003 - SNOW MELTING SYSTEMS | SUBSYSTEM | EA | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| G909099 | G909099 - OTHER SITE CONSTRUCTION | SUBSYSTEM | EA | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| H10 | H10 - WATERFRONT STRUCTURES | MASTERSYSTEM | ● | Yes | ● | ● | ● | ● | ● | |||||||||||||||||||
| H1010 | H1010 - SUBSTRUCTURE | SYSTEM | ● | No | ● | ● | ● | ● | ● | |||||||||||||||||||
| H101004 | H101004 - RELIEVING PLATFORMS | SUBSYSTEM | EA | No | STRUCTURAL | 300 | A | A+ | ||||||||||||||||||||
| H101099 | H101099 - OTHER SUBSTRUCTURE COMPONENTS | SUBSYSTEM | EA | No | CIVIL | 300 | A | A+ | ||||||||||||||||||||
| H1020 | H1020 - SUPERSTRUCTURE | SYSTEM | ● | No | ● | ● | ● | ● | ● |
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .