Appendix C - RKMF103011 BLDG 10432 Fire Sprinkler Shop Drawings.pdf

PDF 9 MB Posted

Attached to
99 CES Fire Suppression Certification
Solicitation number
FA486126Q0025
Issued by

About this file

This document is a technical drawing for F35 Munitions Piping systems serving Building 10432, presenting detailed mechanical and architectural specifications for a remote area design compliant with NFPA 13 (2016) standards.

The drawing provides comprehensive piping system details including a system riser detail front view, section views of the north and south walls of Building 10432, and an air relief detail schematic. The parts legend identifies 15 key components, including existing ductile iron underground piping, grooved concentric reducers, stainless steel grooved end pipes, ball joints, dag-out thru-wall connections, knee braces, water flow switches, sprinkler supply to building 10432, and pressure relief valves. Technical specifications are outlined for remote area design procedures, addressing discharge calculations, minimum design discharge requirements, and hydraulic demand area considerations. The drawing includes revision tracking and notes that detail omitted items. Multiple plan and section views illustrate the integration of piping systems with building infrastructure, including overhead cranes, roofing details, and wall penetrations. Dimensioning and material specifications are provided throughout to guide installation and construction activities.

View the file

Other files

File Type Posted
Solicitation Questions and Answers.pdf PDF
Appendix N - RKMF173010 BLDG 10707 Fire Sprinkler Shop Drawings.pdf PDF
Appendix K - 2025 Hydrant Inspection and Flow Test Data Bldg 10707.pdf PDF
Attachment 1 - Solicitation - FA486126Q0025.pdf PDF
Appendix E - Nellis and Creech AFB IFS_22 Jan 2019.pdf PDF
Appendix A - RKMF 173010 As Built Drawings Sections Fire Plumbing.pdf PDF
Attachment 4 - Performance_Work_Statement__Fire_Suppression_Certification - CAO 25AUG26.pdf PDF
Attachment 2 - Price List.pdf PDF
Appendix D - RKMF103011 BLDG 10440 Fire Sprinkler Shop Drawings.pdf PDF
Appendix B - RKMF 103011 F-35 Muns As Built Drawings Sections Fire Plumbing.pdf PDF
Appendix H - Environmental Permit Guidance.pdf PDF
Attachment 5 - SCA Wage Determination 2015-5593 Revision 32 - CAO 22 AUG 26.pdf PDF
Appendix I - Hydrazine Fuel Storage and Servicing Facility Specification 2144.pdf PDF
Appendix J - Hydrazine Fuel Storage and Servicing Facility Design Analysis.pdf PDF
Appendix G - Nellis AFB Sole Source EMCS Letter.pdf PDF
Appendix K - Hydrant Inspection and Flow Test Data Bldg 10701.pdf PDF
Appendix L - Hydrant Inspection and Flow Test Data Bldg 10432.pdf PDF
Attachment 3 - Past Performance List of References.pdf PDF
Appendix F - Nellis and Creech AFB IFS Mech-Plumb Req_29 Dec 2025.pdf PDF
Appendix M - Hydrant Inspection and Flow Test Data Bldg 10440.pdf PDF