About this file

This document is a detailed architectural drawing (AE503) from the U.S. Department of Veterans Affairs depicting typical roof details for a construction project at Lake City, FL. The drawing provides technical specifications for various roofing configurations, including modified bitumen (mod bit) and thermoplastic polyolefin (TPO) roofing systems, with specific details for pipe penetrations, pipe supports, sleeper supports, and mechanical curbs. Key technical elements include continuous metal capping, edge sealants, roof membrane flashing, insulation layers, wood nailers, and instructions for integrating penetrations and supports while maintaining roof integrity. The drawing is part of the bid documents for the "BB Correct Patient Privacy Deficiencies 2N/2S" project (Project # 573A4-18-603), which is a resolicitation open to small businesses, originally issued under solicitation number 36C24825R0127 for the Veterans Health Administration.

View the file

Other files

File Type Posted
36C24825R0127 0001.pdf PDF
PRIOR SOLICITATION 36C24825R0067 573A418603 Site Visit.pdf PDF
2025 06 24 Site Visit 573A4-18-603.pdf PDF
RFIs 2025 07 09 36C24825R0127 22N2S.xlsx XLSX spreadsheet
36C24825R0127 CLAUSE SHEET.docx DOCX document
Sheet AE452 Headwall Interior Elevations.pdf PDF
SOLICITATION 36C24825R0127 BB Correct PT Privacy Def 2N 2S LC VAMC.pdf PDF
2024 01 29 Drawings Architectural.pdf PDF
2024 01 29 Drawings Mechanical.pdf PDF
Specifications Vol 2.pdf PDF
Specifications Vol 1.pdf PDF
Exhibit E Performance Relevancy Survey v2.docx DOCX document
Visitor Sign In 36C24825R0067 573A418603.pdf PDF
SOLICITATION 36C24825R0127 BB Correct PT Privacy Def 2N 2S LC VAMC.pdf PDF
2024 01 29 Drawings Electrical.pdf PDF
2024 01 29 Drawings Fire Protection.pdf PDF
2024 01 29 Drawings Plumbing.pdf PDF
AE302.pdf PDF
AE709.pdf PDF
SAM DBA 05_02_25.pdf PDF
Exhibit B LOS Certification Solicitation Version.doc DOC document
Exhibit D Contract Progress Schedule.pdf PDF
Exhibit I Price Matrix.xlsx XLSX spreadsheet
RFIs 36C24825R0067 Correct Patient Privacy.xlsx XLSX spreadsheet
2024 01 29 Drawings Structural.pdf PDF
Exhibit C EMR.docx DOCX document
Exhibit F Past and Present Performance Questionnaire.docx DOCX document
RFIs 36C24825R0067 Correct Patient Privacy.pdf PDF
Exhibit A QA RFIs.xlsx XLSX spreadsheet
Show all 29

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FASTENER

PREFIN METAL COUNTER

FLASHING ON METAL CLEAT

PREFAB CURB

2x WOOD NAILERS

MASTIC SEAL

MOD BIT ROOF MEMBRANE

PER SPECIFICATIONS

CANT

TURN MOD BIT STRIP-IN UP

AT CURB

LINE OF MECHANICAL EQUIP

MOD BIT STRIP-IN

1'

4"

4"

NOTE:

ROOF DETAILS VARY BASED ON MFR'S STANDARD

DETAILING.

4"

12" MIN

TURN COUNTERFLASHING

DOWN 1" INTO PIPE

PIPE PENETRATION - FIELD

VERIFY LOCATIONS

PREFIN METAL COUNTERFLASHING

CONT SEALANT

STAINLESS STEEL CLAMPING

RING

MOD BIT STRIP-IN

MOD BIT ROOF MEMBRANE

PER SPECIFICATIONS - TURN

FINISH LAYER UP AT PIPE

MIN 4"

MASTIC SEAL

NOTE:

ROOF DETAILS VARY BASED ON MFR'S STANDARD

DETAILING.

CONT SEALANT

STAINLESS STEEL CLAMPING

RING

MOD BIT STRIP-IN

MOD BIT ROOF MEMBRANE

PER SPECIFICATIONS - TURN

FINISH LAYER UP AT PIPE

MIN 4"

MASTIC SEAL

PREFIN METAL

COUNTERFLASHING

PIPE SUPPORT - FIELD VERIFY

LOCATIONS

NOTE:

ROOF DETAILS VARY BASED ON MFR'S STANDARD

DETAILING.

12" MIN

FASTENER

PREFIN METAL COUNTERFLASHING

ON METAL CLEAT

PREFAB CURB

LINE OF MECHANICAL EQUIP

1'

4"

6"

6"

WELDED SEAM

SINGLE-PLY ROOF MEMBRANE -

TURN UP AT CURB

SINGLE-PLY ROOF FLASHING

NOTE:

ROOF DETAILS VARY BASED ON MFR'S STANDARD

DETAILING.

PIPE PENETRATION - FIELD

VERIFY LOCATIONS

SINGLE-PLY ROOF FLASHING

CONT SEALANT

STAINLESS STEEL CLAMPING

RING

WELDED SEAM

SINGLE-PLY ROOF MEMBRANE

4"

NOTE:

ROOF DETAILS VARY BASED ON MFR'S STANDARD

DETAILING.

METAL FLASHING WHERE REQUIRED

BY MFR

CONT SEALANT

STAINLESS STEEL CLAMPING

RING

PIPE SUPPORT - FIELD VERIFY

LOCATIONS

NOTE:

ROOF DETAILS VARY BASED ON MFR'S STANDARD

DETAILING.

SINGLE-PLY ROOF FLASHING

WELDED SEAM

SINGLE-PLY ROOF MEMBRANE

METAL FLASHING WHERE REQUIRED

BY MFR

2X12 PT BLOCKING AS REQ'D

CONT METAL CAP

WITH COUNTER

FLASHING

CONT EDGE SEALANT

PT 2X WOOD NAILERS

ANCHORED TO DECK

MEMBRANE FLASHING COMPATIBLE WITH

EXISTING ROOFING MEMBRANE- ATTACH

PER MANUFACTURER'S

RECOMMENDATIONS

MEMBRANE ROOFING. X-CUT, PEEL

BACK FROM CUT OPENING AND

PROTECT FOR REINSTALLATION WHERE

APPLICABLE- TYP

ROOF INSULATION

ROOF DECK

DUCTING/PIPING/EQUIPMENT-REFER TO

STRUCTURAL, PLUMBING AND MECHANICAL

DETAIL DRAWINGS FOR ADDITIONAL

INFORMATION

METAL STRAP SECURED TO

CURB WHERE REQUIRED.

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

Date:

Drawing Title:

Approved Project Director

Project Title:

1 2 3 4 5 6 7 8 9

BID DOCUMENTS

590 MEANS ST NW

Phase Project Number

Building Number

Drawing NumberLocation

Issue Date CheckedFULLY SPRINKLERED

STAMP

STE. 200

ATLANTA, GA 30318

ARCHITECT/ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

U.S. Department of Veterans Affairs

Office of Construction and

Facilities Management

Drawn

Building #64

CRM JD/DB/EO5/

/2

9:

:0

A

M

TYPICAL ROOF DETAILS CORRECT PATIENT PRIVACY

DEFICIENCIES - BLDG 64-UNIT A

LAKE CITY VAMC

Lake City, FL

AE503

573A4-18-603

JAN. 29, 2024

3" = 1'-0"AE503

1 MOD BIT ROOFING - MECHANICAL CURB

3" = 1'-0"AE503

2 MOD BIT ROOFING - PIPE PENETRATION

3" = 1'-0"AE503

3 MOD BIT ROOFING PIPE SUPPORT

3" = 1'-0"AE503

5 TPO ROOFING - MECHANICAL CURB

3" = 1'-0"AE503

6 TPO ROOFING - PIPE PENETRATION

3" = 1'-0"AE503

7 TPO ROOFING - PIPE SUPPORT

3" = 1'-0"AE503

4 SLEEPER SUPPORT DETAIL

PROVIDE PIPING AND DUCTWORK SUPPORTS AS REQUIRED PER MECHANICAL

DESIGN. PROVIDE SLEEPER SUPPORT DETAIL AT EACH REQUIRED LOCATION.

SCALE:

0' 2" 4" 8" 1'

3" = 1' - 0"

Sheets
AE302 - WALL SECTIONS AND DETAILS
AE503 - TYPICAL ROOF DETAILS
AE709 - SIGNAGE TYPE AND SCHEDULE