Sheet AE452 Headwall Interior Elevations.pdf

PDF 241 KB Posted

Attached to
BB Correct Patient Privacy Deficiencies 2N/2S Lake City, FL Project # 573A4-18-603
Solicitation number
36C24825R0127
Issued by

About this file

This document is a detailed architectural drawing sheet (AE452) for headwall interior elevations at the Lake City VA Medical Center, specifically for Building 64, Unit A. The drawing provides comprehensive technical specifications for medical headwall systems, including precise dimensional layouts, equipment placement, and component details. The headwall design includes multiple gas outlets (oxygen, medical air, vacuum), electrical receptacles (red and ivory duplex), data and communication provisions, a patient lift docking station, upper cabinet, and bed bumpers. A critical note instructs bidders to verify manufacturer equipment with the government prior to bidding to confirm current vendor status for campus equipment. The project is part of a patient privacy deficiency correction initiative, with room numbers ranging from 2NC-1 to 2SC-1, and is fully sprinklered. The drawing is dated September 29, 2023, and is part of a federal contract opportunity (Solicitation Number 36C24825R0127) for the Department of Veterans Affairs.

View the file

Other files

File Type Posted
2025 06 24 Site Visit 573A4-18-603.pdf PDF
RFIs 2025 07 09 36C24825R0127 22N2S.xlsx XLSX spreadsheet
36C24825R0127 CLAUSE SHEET.docx DOCX document
36C24825R0127 0001.pdf PDF
PRIOR SOLICITATION 36C24825R0067 573A418603 Site Visit.pdf PDF
SOLICITATION 36C24825R0127 BB Correct PT Privacy Def 2N 2S LC VAMC.pdf PDF
SOLICITATION 36C24825R0127 BB Correct PT Privacy Def 2N 2S LC VAMC.pdf PDF
2024 01 29 Drawings Electrical.pdf PDF
2024 01 29 Drawings Fire Protection.pdf PDF
2024 01 29 Drawings Plumbing.pdf PDF
AE302.pdf PDF
AE709.pdf PDF
SAM DBA 05_02_25.pdf PDF
Exhibit B LOS Certification Solicitation Version.doc DOC document
Exhibit D Contract Progress Schedule.pdf PDF
Exhibit I Price Matrix.xlsx XLSX spreadsheet
RFIs 36C24825R0067 Correct Patient Privacy.xlsx XLSX spreadsheet
2024 01 29 Drawings Structural.pdf PDF
AE503.pdf PDF
Exhibit C EMR.docx DOCX document
Exhibit F Past and Present Performance Questionnaire.docx DOCX document
RFIs 36C24825R0067 Correct Patient Privacy.pdf PDF
Exhibit A QA RFIs.xlsx XLSX spreadsheet
2024 01 29 Drawings Architectural.pdf PDF
2024 01 29 Drawings Mechanical.pdf PDF
Specifications Vol 2.pdf PDF
Specifications Vol 1.pdf PDF
Exhibit E Performance Relevancy Survey v2.docx DOCX document
Visitor Sign In 36C24825R0067 573A418603.pdf PDF
Show all 29

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

2.4690

4.0620

2.4688

4.0620

2.4688

4.0620

2.4688

4.0620

2.4688

4.0620

2.4688

4.0620

BB

2.4690

4.0620

2.4688

4.0620

2.4688

4.0620

2.4688

4.0620

2.4688

4.0620

2.4688

4.0620

BB

1' - 11 1/2" 3' - 11 1/2" 1' - 11 1/2"

7' - 10 1/2"

CEILING LINE

A O A O

V V V VSLMSLM

E2 N2

SLM SLM

SC

NCTL

DA

N2

E2

U-DD

BB

FLOOR FINISH

BLOCKING

HANGING BRACKET

BLOCKING

FOR LIGHTING PATIENT LIFT

DOCKING STATION

CABINET

PLAN AT HEADWALL (OP HD)

ELEVATION AT HEADWALL (OP HD)

PATIENT LIFT

OH

SYM QTY DISCRIPTION

HEADWALL LEGEND AND SYSTEM DETAILS

PS 1 PANEL WALL

O 2 GAS OUTLET, OXYGEN

A 2 GAS OUTLET, MED AIR

V 4 GAS OUTLET, VACUUM

E2 2 RECEPTACLE - DUPLEX RED

N2 3 RECEPTACLE - DUPLEX IVORY

DA 1 PROVISION - DATA 1G

SC 1 37 PIN COMM. - 12' CABLES

TL 1 PROVISION - TELEPHONE 1G

NC PROVISION - NURSE CALL 3G

SLM 4 VACUUM SLIDE

U-DD 1 DOUBLE DOOR UPPER CABINET

BB 1 HORIZONTAL BED BUMPERS - A PAIR

NOTE:

FOR THE HEADWALLS LISTED, THIS HEADWALL DESIGN SHALL FORM THE BASIS OF

DESIGN. VERIFY WITH THE GOVERNMENT PRIOR TO BID TO VERIFY IF THE SAID

MANUFACTURER ARE STILL THE VENDOR OF RECORD THAT IS SERVICING THE

LISTED EQUIPMENT FOR THE REST OF THE CAMPUS.

O A

SLM SLM

V V

N2

E2 DA

SLM SLM

A O

V V

E2 N2SC

NC TL

BB

1'

0"

1' - 11 1/2" 3' - 11 1/2" 1' - 11 1/2"

CEILING LINE

7' - 10 1/2"

FLOOR FINISH

BLOCKING

FOR LIGHTING

U-DD

PLAN AT HEADWALL

ELEVATION AT HEADWALL

PATIENT LIFT

6"

1'

6"

2'

0"

4'

0"4'

8"5'

6"

2'

6"

7'

6"

8'

0"

6"

1' - 0"1' - 0"

HEADWALL PANEL

SIDE VIEW AT HEADWALL

PATIENT LIFT DOCKING

STATION CABINET

2NC - 1

2NA - 1

2NE - 1

2NF - 1

2SH - 1

2SG - 1

2SJ - 1

2SD - 1

2SB - 1

ROOM NUMBERS

2NB - 1

2ND - 1

2NJ - 1

2NG - 1

2SH - 1

2SF - 1

2SE - 1

2SA - 1

2SC - 1

ROOM NUMBERS

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

Date:

Drawing Title:

Approved Project Director

Project Title:

1 2 3 4 5 6 7 8 9

BID DOCUMENTS

590 MEANS ST NW

Phase Project Number

Building Number

Drawing NumberLocation

Issue Date CheckedFULLY SPRINKLERED

STAMP

STE. 200

ATLANTA, GA 30318

ARCHITECT/ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

U.S. Department of Veterans Affairs

Office of Construction and

Facilities Management

Drawn

Building #64

CRM JD/DB/EO9/

/2

2:

:5

P

M

HEADWALL INTERIOR ELEVATIONS CORRECT PATIENT PRIVACY

DEFICIENCIES - BLDG 64-UNIT A

LAKE CITY VAMC

Lake City, FL

AE452

573A4-18-603

SEPT. 29, 2023

3/8" = 1'-0"AE452

1 ELEVATION AT HEADWALL - MIRRORED

3/8" = 1'-0"AE452

2 ELEVATION AT HEADWALL

3/8" = 1'-0"AE452

3 SIDE ELEVATION AT HAEDWALL

SCALE:

8'2'0' 4' 6'

3/8" = 1' - 0"

1'

SCALE:

8'2'0' 4' 6'

3/8" = 1' - 0"

1'

File details come from the government source that posted it. Updated .