This file is an Access Requirements drawing prepared for the Solano County Asset Protection Project, which encompasses multiple county facilities located throughout Solano County, California, including properties at Union Avenue, Clay Street, Delaware Street, and Texas Street. The document is a construction phasing plan that identifies vehicle and pedestrian access points across the project sites, which include the Hall of Justice North and South Wings, Solano Justice Center, Solano County Emergency Services, Solano Detention Facility, Sheriff Professional Standards office, Communications center, Cogeneration Plant, and Emergency Services Vehicle Storage facility. The plan designates three categories of vehicle access points (Critical Emergency Access Points requiring 24-hour availability, Important Operational Access Points requiring two-week notice for disruptions, and Major Traffic Access Ways requiring three-week notice and traffic control plans) and three categories of pedestrian access points (Major public and staff entry points requiring three-week notice and accessible alternate access plans, Secure staff entry points requiring two-week notice, and possible egress points requiring two-week notice and fire marshal approval for alternate exit plans). The document also identifies specific operational areas including sheriff response vehicle parking, court maintenance areas, loading bays for various departments, sally ports for the detention facility and coroner's office, and maintenance access routes.
The Access Requirements drawing serves as a critical planning document for contractors undertaking construction activities at the multiple county facilities involved in the Asset Protection Project. Contractors must coordinate all construction phasing, material deliveries, and equipment movement with the stringent access requirements outlined in the plan to ensure continuity of operations at these essential law enforcement, judicial, and emergency services facilities. The document does not address pricing, funding, or contractual terms; rather, it functions as a mandatory operational constraint document that bidders and awarded contractors must incorporate into their construction sequencing, traffic management plans, and site logistics planning to minimize disruption to critical county services during the landscaping and related asset protection work.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AREA LITE
AREA LITE
NO
PARKING
RESERVED
RESERVED
NO
PARKING
RESERVED
NO
PARKING
NO
PARKING
NO
PARKING
NO
PA
RK
IN
G
NO
PARKING
NO
PARKING
NO
PARKING
NO
PARKING
B
BB
B
B
B
B
B
B
B
B
B
B
B
B
B
BB
B
B
B
B
B
B
B
B
B
B
BB
B
B
NO
PA
RK
IN
G
NO
PARKING
NO
PARKING
CR
IC
C R
IC IC
IC
IC
C R
C R
C R
CR
IC
IC
CR
C R
C R
C R
CR
IC
IC
IC
IC
CR
C R
CR
C R
C R
CR
C R
C R
CONSTRUCTION
PHASING
X:
\1
\1
4.
\T
EC
H \C
AD
\P
AR
KI
N G
L O
T
IM
PR
O
VE
M
EN
TS
\G -0
C
O N
ST
R
U C
TI
O
N P
H
AS
IN
G
.D W
G
/2
1/
:4 9:
P
M
SHEET CONTENTS
or l
00 60 120
Vehicle Access Points
A Critical Emergency Vehicle Access Point.
Must remain open to large vehicle access 24 hours a day, 7 days a week. Any disruption to vehicle access route will require immediate mitigation.
B Important Operational Vehicle Access Point. Contractor to provide minimum 2 week notice prior to any activities disrupting access or vehicle route. Alternate access provisions by contractor may be required
C Major Traffic Access Way. Contractor to provide minimum 3 week notice prior to any activity disrupting access. A traffic control plan & encroachment permits are required.
Pedestrian Access Points
1 Major public & staff entry point. Contractor to provide minimum 3 week notice prior to any construction activities disrupting access. An Accessible Alternate Pedestrian Access Plan will be required.
2 Secure Staff entry point. Contractor to provide minimum 2 week notice prior to any activities disrupting access. An Accessible Alternate Pedestrian Access Plan may be required.
3 Possible egress point. Contractor to provide minimum 2 week notice prior to any activities disrupting egress. An alternate exit plan with fire marshal approval may be required.
501 Texas Co-Op Extension / Sheriff Investigations
600 Union Ave Hall of Justice North Wing
600 Union Ave Hall of Justice South Wing
530 Union Ave Solano Justice Center 530 Clay St
Solano County Emergency Services
500 Union Ave Solano Detention Facility
512 Clay St Sheriff Professional Standards
500 Clay St Communications
501 Delaware St Cogeneration Plant
512 Clay St Emergency Services Vehicle Storage
520 Clay st Solano Coroner's Office
Delaware Street
A
A
B
JCDF Sally Port Entrance
Coroner Sally Port Entrance
JCDF
Loading Bay
A JCDF Sally Port Entrance
B OES &
Facilities Vehicles
B
OES &
Facilities Vehicles
B Cogen Loading Bay
C
Washington Street C
Clay Street C
Access Requirements
B
Court Maintenance Area
B Judges Parking
B Sheriff Response Vehicle Parking
B Sheriff Response Vehicle Parking
OES Entry
Office of Professional Standards2 Staff
Entrance
2 Communications
Court Entry
1 Court Entry
1 JCDF
Entry
B Loading Bay
Coop & Sheriff Investigations
B
Maintenance Access
2 Maintenance
2 Maintenance
JCDF
Release Point
B Loading Bay
Staff Entry
2 Staff
Entry
B
Loading Bay
2 Staff Entry
B Loading Bay
2 Staff Entrance
2 Staff Entrance
2 Staff Entrance
A Sally Port
2 Staff Entrance
Staff Entrance
2 Staff Entrance
Staff Entrance 3