A07 ATTACHMENT 0028 TE 4.7 List of Air Compressors.xlsx
XLSX spreadsheet 31 KB Posted
- Solicitation number
- W52P1J-21-R-5001
About this file
This document contains an attachment listing air compressors and related equipment for a federal facilities maintenance contract opportunity. The attachment provides an inventory of 16 air compressors and associated tanks across various buildings and locations at the Rock Island Arsenal in Rock Island, Illinois. Details provided for each compressor and tank include the manufacturer, model, serial number, operating pressures and capacities, port sizes, safety features, and inspection dates. The related solicitation is for base operations support services at the Rock Island Arsenal, including grounds maintenance, facility maintenance for buildings and housing, pest management, hydroelectric plant operations, bridge operations and maintenance, and unscheduled services. The contract period is one base year plus four option years, with an additional six month option to extend services.
View the file
Other files
Show 40 more
Latest 50 of 109 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TE 4.7 List of Air Compressors
| COMPRESSOR INSPECTION LIST | |||||||||||||||||||
| No. | Bldg No | Location Description | Manufacturer | Manuf. Date | Compressor Unit S/N | Compressor (only) S/N | Compressor Unit | ||||||||||||
| Model No. | Compressor | ||||||||||||||||||
| (only) Model No. | Compressor Operating Pressure PSI | Compressor | |||||||||||||||||
| Type | Compressor | ||||||||||||||||||
| HP | Compressor CFM | Compressor | |||||||||||||||||
| Unloader SCFM | Unloader Set Pressure PSI | Unloader Pipe | |||||||||||||||||
| Size, NPT | Port Size | ||||||||||||||||||
| NPT | Drains | Aftercooler | |||||||||||||||||
| 1 | 25 | Proving Grounds Equipment Room Key 22 | Wayne | 1968 | N/A | 195573L | N/A | 390 22 | 110 | Recip | 15 | N/A | 183 | 200 | 1/2" | 1/2" | Auto Drain | ||
| Dayton 6Z948B | Bell & Gosset |
Model 155002
| 2 | 50 | Pump Room East | |||||||||||||||||||||
| Wall North Unit | SpeedAire | 2004 | L 11/4/04‐00591 | F03042201 | 4ME98 | DP500002AV | 110 | Recip | 15.8 @ 90 PSI | ||||||||||||||
| 14.2 @140 PSI | N/A | 120 | 1/4" | 1/4" | Manual Drain | N/A | |||||||||||||||||
| 3 | 50 | Pump Room East | |||||||||||||||||||||
| Wall South Unit | Ingersoll | ||||||||||||||||||||||
| Rand | 1969 | N/A | 30T 288774 | N/A | 242D3 | 110 | Type 30 | 3 | N/A | 42 | 60 | 1/4" | 1/4" | Manual Drain | Refrigerated |
Dryer Pioneer Model R30A Serial# 59256D4A17
| 5 | 102 | NE Corner of Basement Inside Cage | Ingersoll | |||||||||
| Rand | 1992 | N/A | 30T 719699 | N/A | 242‐5N | 110 | Recip | 3 | N/A | 57 | ||
| 118 | 90 | |||||||||||
| 200 | 1/4" | |||||||||||
| 1/4" | 1/4" | |||||||||||
| 1/4" | Armstrong | |||||||||||
| Bucket Trap 800 | N/A | |||||||||||
| 6 | 106 | NW Corner of | ||||||||||
| Basement | Ingersoll | |||||||||||
| Rand | 1992 | N/A | 30T 711966 | 2540 | T3010120H | 110 | Recip | 7.5 | N/A | 52 | ||
| 118 | 80 | |||||||||||
| 200 | 1/4" | |||||||||||
| 1/4" | 1/4" | |||||||||||
| 1/4" | Armstrong | |||||||||||
| Bucket Trap 800 | N/A | |||||||||||
| 7 | 108 | North End Inside | ||||||||||
| Cage | (New Unit) |
Ingersoll
| Rand | 2007 | 801220323 | 7061944 | 15TE20 | 15 T | 170 | Recip | 15 | 73.1 CFM @ | |
| 90 PSI | 209 151 | 325 | ||||||||
| 65 | 1/4" | |||||||||
| 1/2" | 1/4" | |||||||||
| 1/2" | Auto Drain |
Ingersoll Rand ADV Yes, Included on Compressor
| 8 | 131‐1 | North Basement Equipment Room East | Quincy Air | |||||||||||||||
| Star | 1988 | 626 | 6025530 size 4 X 2.25 X 2.78 | ATV‐80‐S | QT 5‐104 | 75 | Recip | 5 | N/A | 63 | 100 | 1/4" | 1/4" | Auto Drain Posi | ||||
| Drain Q7000 | N/A | |||||||||||||||||
| 8 | 131‐2 | North Basement Equipment Room West | Quincy Air | |||||||||||||||
| Star | 1993 | 5039461 | 6032782 | MQC150125 | QT 25 | |||||||||||||
| QCB‐100 | 105 | Recip | 15 | N/A | 63 |
191 100 215 1/4" 1/4" 1/8" 1/4" 1/4" 1/8" Auto Drain Williamson
| 551‐02‐000 | N/A | |||||||||||||||||
| 11 | 139 | NW Corner | Quincy | 1986 | 50113870 | E 10944 | QEH‐10‐80 | QE10‐103 | 140 | Recip | 10 | N/A | 63 | 100 | 1/4" | 1/4" | Auto Drain TSD‐ | |
| 025 | Dominick |
Hunter Refrigerated Dryer DRD 50 Serial #
| 14 | 159 | North End of | ||||||||||||||||||||||
| Basement | Quincy | 1966 | 5105‐6‐54871S | N/A | N/A | 5105‐6 | 130 | Recip | 20 | N/A | 63 | |||||||||||||
| 63 | 100 | |||||||||||||||||||||||
| 100 | 1/4" | |||||||||||||||||||||||
| 1/4" | 1/4" | |||||||||||||||||||||||
| 1/4" | Auto Dayton | |||||||||||||||||||||||
| 62948B | N/A | |||||||||||||||||||||||
| 15 | 159 | Mobile on Service | ||||||||||||||||||||||
| Truck | (New Unit) Puma | 2007 | Q9170191 | N/A | PUK 5508G | 135 | 5.5 | 5.5 CFM‐14.2 | 87 | 140 | 1/4" | 1/4" | Manual Drain | N/A | ||||||||||
| 16 | 160 | Hydro Dam | LeRoi | 1995 | N/A | 4214X143 | W255SSBH‐10 | A219‐198 | 125 | Rotary | 25 | N/A | 157 | 170 | 1/2" | 1/2" | Manual Drain | N/A |
| TE 4.7 List of Air Compressors | ||||||
| Bldg No | Location Description | Tank for Air | ||||
| Compressor | Manufacturer | Manuf. Date | Tank Operating Pressure | Tank Size | ||
| (Gallon) | Tank | |||||
| MAWP | Tank Port | |||||
| Size NPT | Tank Safety Relief Set Pressure | Tank | ||||
| Safety Relief SCFM | Vertical or | |||||
| Horizontal | Relief Valve Pipe Size, NPT | Type of | ||||
| Drain | Pressure Gauge Range | Temperature | ||||
| Max. (Min.) | Head | |||||
| Thickness | Shell | |||||
| Thickness | National |
Board No.
| 25 | Proving Grounds Equip Rm | ||||||||||||||||||||||||||||||
| Key 22 | N/A | Wayne Pump Co | 1968 | 110 | 80 | 200 | 1/4" | 215 | 128 | Horiz | 1/4" | Auto | 0‐160 | 650 | 0.173 | 0.205 | 199901 | ||||||||||||||
| 50 | Pump Room East Wall North Unit | N/A | Speedaire | 2004 | 110 | 60 | 150 | 1/4" | 150 | 92 | Vert | 1/4" | Manual | 0‐300 | 450 | 0.125 | 0.114 | 1282828 | |||||||||||||
| 50 | Pump Room East Wall South Unit | N/A | John Wood | 1969 | 110 | Unknown | 200 | 2" | 150 | 659 | Horiz | 1" | Manual | 0‐300 | 650 | 0.134 | 0.156 | 450314 | |||||||||||||
| 102 | NE Corner of Basement | ||||||||||||||||||||||||||||||
| Inside Cage | N/A | Brunner Eng. | 1992 | 110 | 80 | 200 | 1/4" | 200 | 118 | Vert | 1/4" | Bucket | |||||||||||||||||||
| Trap | 0‐300 | 450 | 0.149 | 0.181 | 93530G | ||||||||||||||||||||||||||
| 106 | NW Corner Of Basement | N/A | Brunner Eng. | 1992 | 110 | 120 | 200 | 1/4" | 200 | 118 | Horiz | 1/4" | Bucket | ||||||||||||||||||
| Trap | 0‐30 | 450 | 0.149 | 0.181 | 71884G | ||||||||||||||||||||||||||
| 108 | North End Inside Cage | N/A | Ingersol | 2007 | 170 | 120 | 200 | 1/4" | 200 | 118 | Horiz | 1/4" | Auto | 0‐300 | 650 | 0.149 | 0.184 | 868640 | |||||||||||||
| 131‐1 | North Basement Equipment | ||||||||||||||||||||||||||||||
| Room East | N/A | Brunner Eng. | 1988 | 75 | 80 | 200 | 1/8", 1/4" | 215, 200 | 118 | Vert | 1/8", 1/4" | Auto | 0‐300 | 450 | 0.141 | 0.181 | 92214E | ||||||||||||||
| 131‐2 | North Basement Equipment | ||||||||||||||||||||||||||||||
| Room West | N/A | Silvan Ind | 1993 | 110 | Unknown | 200 | 1/4" | 150 | 92 | Horiz | 1/4" | Auto | 0‐300 | 450 | 0.149 | 0.187 | 113760 | ||||||||||||||
| 139 | NW Corner | N/A | Brunner Eng. | 1986 | 140 | 80 | 200 | 1/8", 1/4" | 215, 200 | 191, 120 | Horiz | 1/8", 1/4" | Auto | 0‐200 | 450 | 0.132 | 0.151 | 12883E | |||||||||||||
| 159 | North End of Basement | No Storage Tk | Western Tk & Steel | 1966 | 130 | 208 WG | 200 | 3/4" | 165 | 719 | Horiz | 3/4" | Auto | 0‐200 | 300 | 0.199 | 0.218 | 60403 | |||||||||||||
| 159 | Mobil On Service Truck | N/A | |||||||||||||||||||||||||||||
| 160 | Hydro Dam | Storage Tk | Brunner Eng. | 2000 | 125 | 120 WC | 200 | 2"X 2 1/2" | 150 | 4090 | Vert | 2" | Manual | 30 HG‐150 | 450 | 0.149 | 0.181 | 19666 | |||||||||||||
| 160 | Hydro Dam | Compressor | LeRoi Int'l | 1995 | 125 | ? | 200 | 1/2" | 170 | 183 | Vert | 1/2" | Manual | Digital | 650 | 0.091 | 0.049 | 81591 |
TE 4.7 List of Air Compressors Page &P of &N
TE 4.7 List of Air Compressors
File details come from the government source that posted it. Updated .