Typhoon Yutu
HOUSING ASSESSMENT in SUPPORT of Typhoon Yutu DR-4404-MP
Insured: Esther Chong Home: (670) 234-6283 Home: NGUSS Drive Lot 1780 B R1 1/2 Mile Left Top of
Hill Grey
KANNAT TABLA, HI
Property: NGUSS Drive Lot 1780 B R1 1/2 Mile Left Top of Hill Grey
KANNAT TABLA, HI
Claim Number: CNMI-412600376 Policy Number: CNMI-412600376 Type of Loss: Hurricane
Date Contacted: 6/5/2019 1:30 AM Date of Loss: 10/24/2018 2:00 PM Date Received: 6/4/2019 7:27 PM
Date Inspected: 6/5/2019 7:00 PM Date Entered: 6/4/2019 7:31 PM
Date Est. Completed: 6/11/2019 11:59 AM
Price List: HIOI8X_JAN19 Restoration/Service/Remodel
Estimate: CNMI-412600376_RA
HOUSING ASSESSMENT in SUPPORT of Typhoon Yutu DR-4404-MP
CNMI-412600376_RA 12/25/2019 Page: 2
12/22/2019; CMH
Per FEMA Guidance: Test Fee for Lead & Asbestos and one coat PVA primer for all interior wall added to estimate.
12/19/2019: DDH
Site Visits Batch 4 Next Twenty: DeDe Hubbard, Brunson Taylor and Jorge Rivera, PE. The dwelling is a two story CMU with a walkout basement. Half of the roof is tiled and has damages but unable to obtain photos due to 2nd floor.
The other half of the roof is metal and sustained damages. Jorge Rivera, PE has determined the roof will be replaced with 2 gable and 3 shed roofs. Damages addressed to the 1st floor is to R/R Ceiling Joists, add insulation and cove molding. No widows were damaged and the shutters installed prior to the event are good in all rooms except the kitchen which is included in the scope. R/R 200 amp panel and R/R plugs, switches, outlets and GFI's, smoke detectors in the bedrooms and C/O added to the hallway. Ceilings replaced in the rooms where there was water infiltration only. Per new FEMA guidance going forward 1 coat of PVA primer to be applied to all interior walls, along with lead and asbestos test fees, and a dumpster for haul off debris.
INSPECTION SUMMARY
The applicants grandson met at the damaged dwelling and the following was observed.
The dwelling is a two story CMU with a walkout basement. Half of the roof is tiled and is not damaged the other half is metal and sustained damage. The home has 2 occupants and 2 bedrooms occupied.
The dwelling is deemed to be repairable . The one structural component damaged is the roof Reconstruction should take approximately 16 weeks from start of construction.
AGE: 1989
DAMAGE AND REPAIR SUMMARY
See attached estimate for exact repair and line items.
LATITUDE: 15.168157
LONGITUDE: 145.726060
A: ROOF: The metal roof is destroyed and will require replacement from the framing up. The tile roof appears to be ok. The soffit and fascia around the entire roof structure will need replacing.
B: INTERIOR: The 2nd floor interior will require new wood ceilings, insulation for the ceiling, interior doors, and painting for all the doors. The vinyl flooring and base trim in all rooms is damaged and needs replacing and painting. No windows were damaged and the entire first and second floor windows have storm shutters in place that performed well during the event. The first floor needs the ceilings replaced, insulation and cleaning of the tile floors. This area includes only the section under the metal roof.
C: STRUCTURAL: The walls and slab are intact and are not damaged.
D: MECHANICAL/PLUMBING/WATER SYSTEM: Appear to be OK
E: ELECTRICAL: All electric will need replacing from the masthead in.
F: SPRINKLERS (COST NOT IN SCOPE OF WORK)
HOUSING ASSESSMENT in SUPPORT of Typhoon Yutu DR-4404-MP
CNMI-412600376_RA 12/25/2019 Page: 3
COST ARE ESTIMATED ON CES DATA AND SUBJECT TO AVAIALBLE WATER SOURCE.
Concealed fire protection system $9.35 per square feet of living area. This includes sprinkler riser, manifold, heads, head covers, pipes, hardware, all pipes corrosion resistant and installation.
Additional Fire pump & Reservoir could be required cost would be approximately $25,811.37 and would include 20' of pipe with fittings, tank controller equipment and installation. The pump would be 2300 GPM and a 10,000 gallon reservoir.
EVALUATION CRITERIA AND STANDARDS USED
The report is based on visual inspections only. For example, wall reinforcement, plumbing pipes and electrical circuits within the walls cannot be determined without destructive inspection techniques.
Destructive and (High reach) blind spots inspections were not conducted. Inspection reports and pricing is based on what can be seen visually with assumptions on what is observed.
COST SUMMARY:
The project costs, component summary and supporting photos are found in the attached scope of work.
The pricing is based on the repair of the dwelling and associated components as a independent project, utilizing local resources such as labor, materials, equipment, subcontractors, vendors, and suppliers.
The cost assumptions using CES Data;
· Material Handling & Storage Limitations 8%
· Unfavorable Economic Conditions 5%
· Shortage of Available Labor 12%
· General Conditions 20%
· General Contractor's Overhead & Profit 15%
· Payment & Performance Bonds 3%
Permit at fixed $2,000.00 Have been included in this estimate. No local taxes were added.
HOUSING ASSESSMENT in SUPPORT of Typhoon Yutu DR-4404-MP
CNMI-412600376_RA 12/25/2019 Page: 4
CNMI-412600376_RA
Roof Roof
DESCRIPTION QTY
1. 2" x 6" x 20' #2 treated pine (material only) 1.00 EA
2. 2" x 6" x 8' #2 treated pine (material only) 1.00 EA
3. 2" x 6" x 12' #2 treated pine (material only) 2.00 EA
4. 2" x 6" x 92 5/8" pre-cut stud (for 8' wall, mat only) 2.00 EA
5. 2" x 6" x 8' #2 treated pine (material only) 7.00 EA
6. 2" x 6" x 20' #2 treated pine (material only) 13.00 EA
7. 2" x 10" x 12' #2 treated pine (material only) 52.00 EA
8. 2" x 12" x 12' #2 treated pine (material only) 4.00 EA
9. 2" x 12" x 16' #2 treated pine (material only) 4.00 EA
10. 2" x 12" x 20' #2 treated pine (material only) 4.00 EA
11. Install Sheathing - plywood - 1/2" - treated 192.46 SF
12. Material Only Sheathing - plywood - 1/2" - treated 192.46 SF
13. Install Sheathing - plywood - 3/4" - treated 864.00 SF
14. Material Only Sheathing - plywood - 3/4" - treated 864.00 SF
15. Labor to frame 2" x 6" non-bearing wall - 16" oc 27.81 SF
16. Rafters - 2x6 - Labor only - (using rafter length) 300.20 LF
17. R&R Rafters - 2x10 - Labor only - (using rafter length) 618.88 LF
18. R&R Rafters - 2x12 - Labor only - (using rafter length) 190.61 LF
NOTES:
Roof1
(A)F1
(B)F2
35' 8"
' 1
1"
' 7
' 1
1"
' 7
' 1
Roof1
848.97 Surface Area
118.94 Total Perimeter Length
8.49 Number of Squares
35.67 Total Ridge Length
DESCRIPTION QTY
------------------ ROOFING -----------------
19. Remove Metal roofing - ribbed - 24 gauge - up to 1" 848.97 SF
HOUSING ASSESSMENT in SUPPORT of Typhoon Yutu DR-4404-MP
CNMI-412600376_RA 12/25/2019 Page: 5
CONTINUED - Roof1
DESCRIPTION QTY
20. Install Metal roofing - ribbed - 24 gauge - up to 1" 848.97 SF
21. Material Only Metal roofing - ribbed - 24 gauge - up to 1" 848.97 SF
22. Closure strips for metal roofing - inside and/or outside 71.33 LF
23. Flashing tape - self-adhesive 333.17 LF
Seal between the metal roof seams
24. Ridge vent - Metal roofing - floating ventilator 35.67 LF
25. Additional screws for 3/4 plywood sheathing 4159.00 EA
Additional screws for 3/4 plywood sheathing above Xactimate pricing. 6% waste added Includes labor @.66
26. Additional screws for 2X4 & 2x6 furring, and fascia 960.00 EA
Additional screws for 2X4 & 2x6 furring, and fascia above Xactimate pricing. 6% waste added Includes labor @.66
27. Drip edge/gutter apron 71.33 LF
28. Install Gable trim for metal roofing - 26 gauge 47.61 LF
29. Material Only Gable trim for metal roofing - 26 gauge 47.61 LF
30. Ice & water barrier 848.97 SF
31. Neoprene pipe jack flashing for metal roofing 1.00 EA
32. Install 2" x 4" lumber - treated (.667 BF per LF) 277.33 LF
Roof purlins
33. Material Only 2" x 4" lumber - treated (.667 BF per LF) 277.33 LF
Roof purlins
34. Install 2" x 6" lumber - treated (1 BF per LF) 190.27 LF
For Picture Frame Purlins
35. Material Only 2" x 6" lumber - treated (1 BF per LF) 190.27 LF
For Picture Frame Purlins
36. Install 2" x 6" lumber - treated (1 BF per LF) 142.67 LF
Rafter Blocking
37. Material Only 2" x 6" lumber - treated (1 BF per LF) 142.67 LF
Rafter Blocking
------------------ SOFFIT -----------------
38. Install Soffit - box framing - 1' overhang 94.87 LF
Calculation set for 16" overhang
39. Material Only Soffit - box framing - 1' overhang 94.87 LF
Calculation set for 16" overhang
40. Install Soffit & fascia - wood - 1' overhang 94.87 LF
HOUSING ASSESSMENT in SUPPORT of Typhoon Yutu DR-4404-MP
CNMI-412600376_RA 12/25/2019 Page: 6
CONTINUED - Roof1
DESCRIPTION QTY
Calculation set for 16" overhang
41. Material Only Soffit & fascia - wood - 1' overhang 94.87 LF
Calculation set for 16" overhang
42. Baffle vent - foam 71.33 LF
Cut to fit as needed for vents
43. Soffit vent - linear 35.67 LF
------------------ PAINT -----------------
44. Prime & paint exterior soffit - wood 94.87 SF
45. Prime & paint exterior fascia - wood, 4"- 6" wide 142.67 LF
Doubling the amount as the Fascia is 2x12 and XM8 line item covers only 6 inch fascia wood.
46. Exterior - paint two coats 96.23 SF
47. Siding - hardboard panel - paint grade 96.23 SF
48. House wrap (air/moisture barrier) 96.23 SF
------------------ STRAPPING -----------------
49. 2x10 Joist hangers for rafters 52.00 EA
2x10 Joist hangers for rafters
50. Joist hangers for 2x6 rafter blocking 108.00 EA
Joist hangers for 2x6 rafter blocking, Typical one side of blocking per plans
51. Framing hurricane tie 289.00 EA
For rafter tails and gable wall studs top and bottom
52. Install Framing hurricane tie 16.00 EA
For joist to top plate
53. Material Only Framing hurricane tie 16.00 EA
For joist to top plate
54. Framing strap - 24" long 27.00 EA
55. Lag bolt - 1/2" x 5" - hex lag screw - zinc plated 128.00 EA
4 @ each rafter section & 24 at the splice on the ridge
NOTES:
ROOF 2
HOUSING ASSESSMENT in SUPPORT of Typhoon Yutu DR-4404-MP
CNMI-412600376_RA 12/25/2019 Page: 7
DESCRIPTION QTY
56. 2" x 6" x 8' #2 treated pine (material only) 31.00 EA
57. 2" x 6" x 10' #2 treated pine (material only) 4.00 EA
58. 2" x 6" x 12' #2 treated pine (material only) 5.00 EA
59. 2" x 6" x 14' #2 treated pine (material only) 13.00 EA
60. 2" x 6" x 16' #2 treated pine (material only) 4.00 EA
61. 2" x 6" x 116 5/8" pre-cut stud (for 10' wall, mat only) 1.00 EA
62. 2" x 6" x 18' #2 treated pine (material only) 2.00 EA
63. 2" x 6" x 20' #2 treated pine (material only) 12.00 EA
64. 2" x 6" x 92 5/8" pre-cut stud (for 8' wall, mat only) 26.00 EA
65. 2" x 10" x 8' #2 treated pine (material only) 2.00 EA
66. 2" x 10" x 10' #2 treated pine (material only) 8.00 EA
67. 2" x 10" x 14' #2 treated pine (material only) 61.00 EA
68. 2" x 12" x 10' #2 treated pine (material only) 6.00 EA
69. 2" x 12" x 8' #2 treated pine (material only) 5.00 EA
70. 2" x 12" x 14' #2 treated pine (material only) 11.00 EA
71. 2" x 12" x 18' #2 treated pine (material only) 1.00 EA
72. 2" x 12" x 20' #2 treated pine (material only) 4.00 EA
73. Install Sheathing - plywood - 1/2" - treated 650.74 SF
74. Material Only Sheathing - plywood - 1/2" - treated 650.74 SF
75. Install Sheathing - plywood - 3/4" - treated 1248.00 SF
76. Material Only Sheathing - plywood - 3/4" - treated 1248.00 SF
77. Labor to frame 2" x 6" non-bearing wall - 16" oc 323.27 SF
78. Rafters - 2x6 - Labor only - (using rafter length) 268.66 LF
79. R&R Rafters - 2x10 - Labor only - (using rafter length) 868.50 LF
80. R&R Rafters - 2x12 - Labor only - (using rafter length) 326.92 LF
NOTES:
Roof 4
(A)F1
(B)F2
Roof1 F3
Roof2 F4
Roof3 F5
6' 5'
1"
2' 2"
7'
7'
17' 5"
2' 2"
13' 1"
' 7
' 5
Roof1
211.06 Surface Area
62.04 Total Perimeter Length
2.11 Number of Squares
HOUSING ASSESSMENT in SUPPORT of Typhoon Yutu DR-4404-MP
CNMI-412600376_RA 12/25/2019 Page: 8
DESCRIPTION QTY
------------------ ROOFING -----------------
81. Remove Metal roofing - ribbed - 24 gauge - up to 1" 211.06 SF
82. Install Metal roofing - ribbed - 24 gauge - up to 1" 211.06 SF
83. Material Only Metal roofing - ribbed - 24 gauge - up to 1" 211.06 SF
84. Closure strips for metal roofing - inside and/or outside 34.83 LF
85. Flashing tape - self-adhesive 179.92 LF
Seal between the metal roof seams
86. Additional screws for 3/4 sheathing 1393.00 EA
Additional screws for 3/4 sheathing above Xactimate allowance. 6% waste added for screws Labor Included
87. Additional screws for 2x4 & 2x6 furring and fascia 295.00 EA
Additional screws for 2x4 & 2x6 furring and fascia above Xactimate allowance. 6% waste added for screws Labor included
88. Drip edge/gutter apron 17.42 LF
89. Install Gable trim for metal roofing - 26 gauge 27.20 LF
90. Material Only Gable trim for metal roofing - 26 gauge 27.20 LF
91. Ice & water barrier 211.06 SF
92. Flashing, 20" wide 17.42 LF
93. Install 2" x 4" lumber (.667 BF per LF) 87.08 LF
Roof purlins
94. Material Only 2" x 4" lumber (.667 BF per LF) 87.08 LF
Roof purlins
95. Install 2" x 6" lumber (1 BF per LF) 62.04 LF
For Picture Frame
96. Material Only 2" x 6" lumber (1 BF per LF) 62.04 LF
For Picture Frame
97. Install 2" x 6" lumber (1 BF per LF) 104.50 LF
Rafter Blocking
98. Material Only 2" x 6" lumber (1 BF per LF) 104.50 LF
Blocking For Rafters
------------------ SOFFIT -----------------
99. Install Soffit - box framing - 1' overhang 17.42 LF
Calculation set for 16" overhang
100. Material Only Soffit - box framing - 1' overhang 17.42 LF
Calculation set for 16" overhang
101. Install Soffit & fascia - wood - 1' overhang 17.42 LF
Calculation set for 16" overhang
102. Material Only Soffit & fascia - wood - 1' overhang 17.42 LF
Calculation set for 16" overhang
103. Soffit vent - linear 17.42 LF
Cut to fit for soffit vent
HOUSING ASSESSMENT in SUPPORT of Typhoon Yutu DR-4404-MP
CNMI-412600376_RA 12/25/2019 Page: 9
CONTINUED - Roof1
DESCRIPTION QTY
104. Baffle vent - foam 17.42 LF
------------------ PAINT -----------------
105. Prime & paint exterior soffit - wood 23.16 SF
106. Prime & paint exterior fascia - wood, 4"- 6" wide 34.83 LF
Doubling the amount as the Fascia is 2x12 and XM8 line item covers only 6 inch fascia wood.
------------------ STRAPPING -----------------
107. 2x10 Joist hangers for rafters 14.00 EA
2x10 Joist hangers for rafters
108. 2x6 joist hangers for rafter blocking 48.00 EA
2x6 joist hangers for rafter blocking in the roof.
109. Framing hurricane tie 54.00 EA
Rafter to wall hurricane tie - 2 per rafter per plans. (Not GFM)
NOTES:
Roof 4
(A)F1
(B)F2
Roof1 F3
Roof2 F4
Roof3 F5
' 7
9' 6" 9' 4"
Roof2
118.75 Surface Area
31.47 Total Perimeter Length
1.19 Number of Squares
DESCRIPTION QTY
------------------ ROOFING -----------------
110. Remove Metal roofing - ribbed - 24 gauge - up to 1" 118.75 SF
111. Install Metal roofing - ribbed - 24 gauge - up to 1" 118.75 SF
112. Material Only Metal roofing - ribbed - 24 gauge - up to 1" 118.75 SF
113. Closure strips for metal roofing - inside and/or outside 12.55 LF
114. Flashing tape - self-adhesive 31.54 LF
HOUSING ASSESSMENT in SUPPORT of Typhoon Yutu DR-4404-MP
CNMI-412600376_RA 12/25/2019 Page: 10
CONTINUED - Roof2
DESCRIPTION QTY
Seal between the metal roof seams
115. Additional screws for 3/4 sheathingAdditional screws for 3/4 sheathing 789.00 EA
Additional screws for 3/4 sheathing above Xactimate allowance. 6% waste added for screws Labor included
116. Additional screws for 2x4 & 2x6 furring and fascia 228.00 EA
Additional screws for 2x4 & 2x6 furring and fascia above Xactimate allowance. 6% waste added for screws Labor included
117. Drip edge/gutter apron 12.55 LF
118. Install Gable trim for metal roofing - 26 gauge 18.92 LF
119. Material Only Gable trim for metal roofing - 26 gauge 18.92 LF
120. Ice & water barrier 118.75 SF
121. Flashing, 20" wide 6.27 LF
122. Install 2" x 4" lumber (.667 BF per LF) 18.82 LF
Roof purlins
123. Material Only 2" x 4" lumber (.667 BF per LF) 18.82 LF
Roof purlins
124. Install 2" x 6" lumber (1 BF per LF) 44.02 LF
For Picture Frame
125. Material Only 2" x 6" lumber (1 BF per LF) 44.02 LF
For Picture Frame
126. Install 2" x 6" lumber (1 BF per LF) 25.10 LF
Rafter Blocking
127. Material Only 2" x 6" lumber (1 BF per LF) 25.10 LF
Blocking For Rafters
------------------ SOFFIT -----------------
128. Install Soffit - box framing - 1' overhang 12.55 LF
Calculation set for 16" overhang
129. Material Only Soffit - box framing - 1' overhang 12.55 LF
Calculation set for 16" overhang
130. Install Soffit & fascia - wood - 1' overhang 12.55 LF
Calculation set for 16" overhang
131. Material Only Soffit & fascia - wood - 1' overhang 12.55 LF
Calculation set for 16" overhang
132. Soffit vent - linear 6.27 LF
HOUSING ASSESSMENT in SUPPORT of Typhoon Yutu DR-4404-MP
CNMI-412600376_RA 12/25/2019 Page: 11
CONTINUED - Roof2
DESCRIPTION QTY
133. Baffle vent - foam 12.55 LF
------------------ PAINT -----------------
134. Prime & paint exterior soffit - wood 16.69 SF
135. Prime & paint exterior fascia - wood, 4"- 6" wide 25.10 LF
Doubling the amount as the Fascia is 2x12 and XM8 line item covers only 6 inch fascia wood.
------------------ STRAPPING -----------------
136. 2x10 Joist hangers for rafters 5.00 EA
2x10 Joist hangers for rafters
137. 2x6 joist hangers for rafter blocking 22.00 EA
2x6 joist hangers for rafter blocking in the roof.
138. Framing hurricane tie 20.00 EA
Rafter to wall hurricane tie - 2 per rafter per plans. (Not GFM)
NOTES:
Roof 4
(A)F1
(B)F2
Roof1 F3
Roof2 F4
Roof3 F5
13' 3"
' 2
Roof3
161.19 Surface Area
50.83 Total Perimeter Length
1.61 Number of Squares
DESCRIPTION QTY
------------------ ROOFING -----------------
139. Remove Metal roofing - ribbed - 24 gauge - up to 1" 161.19 SF
140. Install Metal roofing - ribbed - 24 gauge - up to 1" 161.19 SF
141. Material Only Metal roofing - ribbed - 24 gauge - up to 1" 161.19 SF
142. Closure strips for metal roofing - inside and/or outside 26.50 LF
143. Flashing tape - self-adhesive 123.82 LF
HOUSING ASSESSMENT in SUPPORT of Typhoon Yutu DR-4404-MP
CNMI-412600376_RA 12/25/2019 Page: 12
CONTINUED - Roof3
DESCRIPTION QTY
Seal between the metal roof seams
144. Additional screws for 3/4 sheathing 1009.00 EA
Additional screws for 3/4 sheathing above Xactimate allowance. 6% waste added for screws Labor included
145. Additional screws for 2x4 & 2x6 furring & fascia 273.00 EA
Additional screws for 2x4 & 2x6 furring & fascia above Xactimate allowance. 6% waste added for screws Labor included
146. Drip edge/gutter apron 13.25 LF
147. Install Gable trim for metal roofing - 26 gauge 24.33 LF
148. Material Only Gable trim for metal roofing - 26 gauge 24.33 LF
149. Ice & water barrier 161.19 SF
150. Flashing, 20" wide 13.25 LF
151. Install 2" x 4" lumber (.667 BF per LF) 53.00 LF
Roof purlins
152. Material Only 2" x 4" lumber (.667 BF per LF) 53.00 LF
Roof purlins
153. Install 2" x 6" lumber (1 BF per LF) 50.83 LF
For Picture Frame
154. Material Only 2" x 6" lumber (1 BF per LF) 50.83 LF
For Picture Frame
155. Install 2" x 6" lumber (1 BF per LF) 79.50 LF
Rafter Blocking
156. Material Only 2" x 6" lumber (1 BF per LF) 79.50 LF
Blocking For Rafters
------------------ SOFFIT -----------------
157. Install Soffit - box framing - 1' overhang 13.25 LF
Calculation set for 16" overhang
158. Material Only Soffit - box framing - 1' overhang 13.25 LF
Calculation set for 16" overhang
159. Install Soffit & fascia - wood - 1' overhang 13.25 LF
Calculation set for 16" overhang
160. Material Only Soffit & fascia - wood - 1' overhang 13.25 LF
Calculation set for 16" overhang
161. Soffit vent - linear 13.25 LF
HOUSING ASSESSMENT in SUPPORT of Typhoon Yutu DR-4404-MP
CNMI-412600376_RA 12/25/2019 Page: 13
CONTINUED - Roof3
DESCRIPTION QTY
162. Baffle vent - foam 13.25 LF
------------------ PAINT -----------------
163. Prime & paint exterior soffit - wood 17.62 SF
164. Prime & paint exterior fascia - wood, 4"- 6" wide 26.50 LF
Doubling the amount as the Fascia is 2x12 and XM8 line item covers only 6 inch fascia wood.
------------------ STRAPPING -----------------
165. 2x10 Joist hangers for rafters 10.00 EA
2x10 Joist hangers for rafters
166. 2x6 joist hangers for rafter blocking 33.00 EA
2x6 joist hangers for rafter blocking in the roof.
167. Framing hurricane tie 40.00 EA
Rafter to wall hurricane tie - 2 per rafter per plans. (Not GFM)
NOTES:
Roof 4
(A)F1
(B)F2
Roof1 F3
Roof2 F4
Roof3 F5
29' 9"
' 7
' 3
' 7
' 3
' 5
Roof 4
748.95 Surface Area
79.18 Total Perimeter Length
7.49 Number of Squares
29.75 Total Ridge Length
DESCRIPTION QTY
------------------ ROOFING -----------------
168. Remove Metal roofing - ribbed - 24 gauge - up to 1" 748.95 SF
169. Install Metal roofing - ribbed - 24 gauge - up to 1" 748.95 SF
170. Material Only Metal roofing - ribbed - 24 gauge - up to 1" 748.95 SF
171. Closure strips for metal roofing - inside and/or outside 28.83 LF
172. Flashing tape - self-adhesive 286.07 LF
HOUSING ASSESSMENT in SUPPORT of Typhoon Yutu DR-4404-MP
CNMI-412600376_RA 12/25/2019 Page: 14
CONTINUED - Roof 4
DESCRIPTION QTY
Seal between the metal roof seams
173. Ridge vent - Metal roofing - floating ventilator 29.75 LF
174. Additional screws for 3/4 plywood sheathing 3740.00 EA
Additional screws for 3/4 plywood sheathing above Xactimate pricing. 6% waste added Labor included
175. Additional screws for 2X4 & 2x6 furring and fascia 758.00 EA
Additional screws for 2X4 & 2x6 furring and fascia above Xactimate pricing. 6% waste added Labor included
176. Drip edge/gutter apron 28.83 LF
177. Install Gable trim for metal roofing - 26 gauge 50.35 LF
178. Material Only Gable trim for metal roofing - 26 gauge 50.35 LF
179. Ice & water barrier 748.95 SF
180. Neoprene pipe jack flashing for metal roofing 1.00 EA
181. Install 2" x 4" lumber - treated (.667 BF per LF) 287.50 LF
Roof purlins
182. Material Only 2" x 4" lumber - treated (.667 BF per LF) 287.50 LF
Roof purlins
183. Install 2" x 6" lumber - treated (1 BF per LF) 138.68 LF
For Picture Frame Purlins
184. Material Only 2" x 6" lumber - treated (1 BF per LF) 138.68 LF
For Picture Frame Purlins
185. Install 2" x 6" lumber - treated (1 BF per LF) 178.50 LF
Rafter Blocking
186. Material Only 2" x 6" lumber - treated (1 BF per LF) 178.50 LF
Rafter Blocking
------------------ SOFFIT -----------------
187. Install Soffit - box framing - 1' overhang 38.35 LF
Calculation set for 16" overhang
188. Material Only Soffit - box framing - 1' overhang 38.35 LF
Calculation set for 16" overhang
189. Install Soffit & fascia - wood - 1' overhang 38.35 LF
Calculation set for 16" overhang
190. Material Only Soffit & fascia - wood - 1' overhang 38.35 LF
Calculation set for 16" overhang
191. Baffle vent - foam 28.83 LF
HOUSING ASSESSMENT in SUPPORT of Typhoon Yutu DR-4404-MP
CNMI-412600376_RA 12/25/2019 Page: 15
CONTINUED - Roof 4
DESCRIPTION QTY
Cut to fit as needed for vents
192. Soffit vent - linear 14.42 LF
------------------ PAINT -----------------
193. Prime & paint exterior soffit - wood 38.35 SF
194. Prime & paint exterior fascia - wood, 4"- 6" wide 57.67 LF
Doubling the amount as the Fascia is 2x12 and XM8 line item covers only 6 inch fascia wood.
195. Exterior - paint two coats 325.37 SF
This line item includes paint siding and house wrap for all 2nd floor roofs.
196. Siding - hardboard panel - paint grade 325.37 SF
197. House wrap (air/moisture barrier) 325.37 SF
------------------ STRAPPING -----------------
198. 2x10 Joist hangers for rafters 44.00 EA
2x10 Joist hangers for rafters
199. Joist hangers for 2x6 rafter blocking 120.00 EA
Joist hangers for 2x6 rafter blocking, Typical one side of blocking per plans
200. Framing hurricane tie 278.00 EA
For rafter tails and gable wall studs top and bottom
201. Install Framing hurricane tie 16.00 EA
For joist to top plate
202. Material Only Framing hurricane tie 16.00 EA
For joist to top plate
203. Framing strap - 24" long 21.00 EA
204. Lag bolt - 1/2" x 5" - hex lag screw - zinc plated 112.00 EA
4 @ each rafter section & 24 at the splice on the ridge
NOTES:
Main Main
DESCRIPTION QTY
------------------ ELECTRICAL -----------------
HOUSING ASSESSMENT in SUPPORT of Typhoon Yutu DR-4404-MP
CNMI-412600376_RA 12/25/2019 Page: 16
CONTINUED - Main
DESCRIPTION QTY
205. R&R Meter mast for overhead power - 2" conduit 1.00 EA
206. R&R Meter base - 200 amp 1.00 EA
207. R&R Breaker panel - 200 amp w/arc fault breakers 1.00 EA
208. Circuit breaker - main disconnect - 150 to 200 amp 1.00 EA
209. Rewire - average residence - copper wiring 1894.53 SF
210. R&R Ground fault interrupter (GFI) outlet 1.00 EA
211. R&R Exterior light fixture 1.00 EA
212. R&R Grounding rod - copper clad with clamp, 8' 2.00 EA
213. R&R Trunk cable - aluminum - 4 wire 2/0 5.00 LF
------------------ WALL REPAIRS-----------------
214. Wedge anchor bolt - 1/2" x 8 1/2" 184.00 EA
For cold joint between top of wall and new bond beam.
215. Epoxy crack and joint filler (per LF of crack) 184.00 LF
216. Install 2" x 6" lumber - treated (1 BF per LF) 880.56 LF
For double sill plate on the perimeter
217. Material Only 2" x 6" lumber - treated (1 BF per LF) 880.56 LF
For double sill plate on the perimeter
218. Sill seal foam - 6" 244.54 LF
------------------ SCAFFOLD -----------------
219. Scaffolding Setup & Take down - per hour 32.00 HR
------------------ GENERAL ITEMS -----------------
220. Clean the floor - Heavy 1894.53 SF
221. Dumpster load - Approx. 20 yards, 4 tons of debris 1.00 EA
For haul off and dump fees
222. Lead test fee - full service lead survey 1.00 EA
For Lead testing when applicable
223. Asbestos test fee - full service survey - base fee 1.00 EA
For Asbestos testing when applicable
224. Seal the walls w/PVA primer - one coat 4760.79 SF
Apply one coat PVA Stain block to all interior walls
HOUSING ASSESSMENT in SUPPORT of Typhoon Yutu DR-4404-MP
CNMI-412600376_RA 12/25/2019 Page: 17
CONTINUED - Main
DESCRIPTION QTY
NOTES:
Up
Up Closet 2 (1) Hallway 2
G
FC
I
Closet 1 (1)
Den
Bathroom 2
Stairs
Dining Room
Pantry
Bedroom 2
Hallway
Bedroom 1 Kitchen
Living Room
Bathroom 1
Entry/Foyer
6'
6'
7' 2'
2' 4'
6' 11"
9"
5'
1"
' 1 0"
' 4
6'
1"
7'
3'
5'
2' 2" 2' 1" 2' 3"
2' 4"
2' 2" Living Room Height: 8'
544.02 SF Walls
1071.65 SF Walls & Ceiling
58.63 SY Flooring
73.46 LF Ceil. Perimeter
527.63 SF Ceiling
527.63 SF Floor
66.46 LF Floor Perimeter
Missing Wall - Goes to Floor 7' X 6' 8" Opens into DEN
Missing Wall 3' 9 1/16" X 8' Opens into HALLWAY
Missing Wall 2' 11 3/4" X 8' Opens into STAIRS2
Missing Wall 3' 2 1/4" X 8' Opens into STAIRS
Missing Wall 5' 11 1/16" X 8' Opens into HALLWAY_2
Up
Up Closet 2 (1)
Hallway 2
G
FC
I
Closet 1 (1)
Den
Bathroom 2
Stairs
Dining Room
Pantry
Bedroom 2
Hallway
Bedroom 1
Kitchen
Living Room
Bathroom 1
Entry/Foyer 1' 2"
6"
6"
4'
4'
1' 8"
4'
4'
Subroom: Room5 (1) Height: 8'
81.14 SF Walls
88.02 SF Walls & Ceiling
0.76 SY Flooring
10.14 LF Ceil. Perimeter
6.88 SF Ceiling
6.88 SF Floor
10.14 LF Floor Perimeter
Missing Wall 1' 7 7/8" X 8' Opens into LIVING_ROOM
Up
Up
Closet 2 (1)
Hallway 2
G
FC
I
Closet 1 (1)
Den
Bathroom 2
Stairs
Dining Room
Pantry
Bedroom 2
Hallway
Bedroom 1
Kitchen
Living Room
Bathroom 1
Entry/Foyer
2' 6"
3' 5"
2' 6"
3' 6"
9"
1'
1'
6' 11"
1'
Subroom: Room2 (2) Height: 8'
72.70 SF Walls
80.55 SF Walls & Ceiling
0.87 SY Flooring
9.09 LF Ceil. Perimeter
7.85 SF Ceiling
7.85 SF Floor
9.09 LF Floor Perimeter
Missing Wall 6' 11 3/16" X 8' Opens into LIVING_ROOM
HOUSING ASSESSMENT in SUPPORT of Typhoon Yutu DR-4404-MP
CNMI-412600376_RA 12/25/2019 Page: 18
DESCRIPTION QTY
------------------ ELECTRICAL -----------------
225. R&R Switch 5.00 EA
226. R&R Light fixture 4.00 EA
227. R&R Outlet 4.00 EA
------------------ DOORS & WINDOWS -----------------
228. Security/storm shutter 27.50 SF
NOTES:
Up
Up Closet 2 (1)
Hallway 2
G
FC
I
Closet 1 (1)
Den
Bathroom 2
Stairs
Dining Room
Pantry
Bedroom 2
Hallway
Bedroom 1
Kitchen
Living Room
Bathroom 1
Entry/Foyer
6'
3'
3' 2" 2' 4"
3'
2'
6'
5'
0"
12'
11' 4"
7' 2'
2'
2'
2'
Den Height: 8'
294.30 SF Walls
422.73 SF Walls & Ceiling
14.27 SY Flooring
45.33 LF Ceil. Perimeter
128.42 SF Ceiling
128.42 SF Floor
35.08 LF Floor Perimeter
Missing Wall - Goes to Floor 3' 3" X 6' 8" Opens into KITCHEN
Missing Wall - Goes to Floor 7' X 6' 8" Opens into LIVING_ROOM
DESCRIPTION QTY
------------------ ELECTRICAL -----------------
229. R&R Switch 2.00 EA
230. R&R Light fixture 1.00 EA
231. R&R Outlet 2.00 EA
------------------ INSULATION -----------------
232. Batt insulation - 10" - R30 - paper faced 128.42 SF
------------------ WALLS & CEILINGS -----------------
233. Remove Sheathing - plywood - 1/2" - treated 128.42 SF
234. Install Sheathing - plywood - 1/2" - treated 128.42 SF
235. Material Only Sheathing - plywood - 1/2" - treated 128.42 SF
236. Seal & paint plywood sheathing 128.42 SF
237. Remove Joist - floor or ceiling - 2x6 - w/blocking - 16" oc 128.42 SF
238. Install Joist - floor or ceiling - 2x6 - w/blocking - 16" oc 128.42 SF
239. Material Only Joist - floor or ceiling - 2x6 - w/blocking - 16" oc 128.42 SF
240. Cove molding - 3/4" 45.33 LF
HOUSING ASSESSMENT in SUPPORT of Typhoon Yutu DR-4404-MP
CNMI-412600376_RA 12/25/2019 Page: 19
CONTINUED - Den
DESCRIPTION QTY
NOTES:
Up Up Closet 2 (1)
Hallway 2
G
FC
I
Closet 1 (1)
Den
Bathroom 2
Stairs
Dining Room
Pantry
Bedroom 2
Hallway
Bedroom 1
Kitchen
Living Room
Bathroom 1
Entry/Foyer
8'
' 5
4' 3' 8" 3' 10"
6'
6' 2"
4'
5' 3'
3'
6'
5'
0"
2' 6"
9' 3"
9' 5"
1' 11" Kitchen Height: 8'
429.75 SF Walls
709.53 SF Walls & Ceiling
31.09 SY Flooring
56.43 LF Ceil. Perimeter
279.78 SF Ceiling
279.78 SF Floor
53.18 LF Floor Perimeter
Missing Wall 8' X 8' Opens into DINING_ROOM
Missing Wall 3' 9 1/16" X 8' Opens into HALLWAY
Missing Wall - Goes to Floor 3' 3" X 6' 8" Opens into DEN
DESCRIPTION QTY
------------------ ELECTRICAL -----------------
241. R&R Switch 3.00 EA
242. R&R Light fixture 1.00 EA
243. R&R Outlet 5.00 EA
244. R&R Ground fault interrupter (GFI) outlet 2.00 EA
------------------ INSULATION -----------------
245. Batt insulation - 10" - R30 - paper faced 279.78 SF
------------------ WALLS & CEILINGS -----------------
246. Remove Sheathing - plywood - 1/2" - treated 279.78 SF
247. Install Sheathing - plywood - 1/2" - treated 279.78 SF
248. Material Only Sheathing - plywood - 1/2" - treated 279.78 SF
249. Seal & paint plywood sheathing 279.78 SF
250. Remove Joist - floor or ceiling - 2x6 - w/blocking - 16" oc 279.78 SF
251. Install Joist - floor or ceiling - 2x6 - w/blocking - 16" oc 279.78 SF
252. Material Only Joist - floor or ceiling - 2x6 - w/blocking - 16" oc 279.78 SF
253. Cove molding - 3/4" 56.43 LF
------------------ DOORS & WINDOWS -----------------
HOUSING ASSESSMENT in SUPPORT of Typhoon Yutu DR-4404-MP
CNMI-412600376_RA 12/25/2019 Page: 20
CONTINUED - Kitchen
DESCRIPTION QTY
254. Security/storm shutter 14.00 SF
------------------GENERAL ITEMS -----------------
255. 5 lb. ABC fire extinguisher 1.00 EA
NOTES:
Up
Up Closet 2 (1)
Hallway 2
G
FC
I
Closet 1 (1)
Den
Bathroom 2
Stairs
Dining Room
Pantry
Bedroom 2
Hallway
Bedroom 1
Kitchen
Living Room
Bathroom 1
Entry/Foyer
8'
' 5
2' 6"
2' 1" 3'
3' 1"
3' 1'
1'
1"
' 3
' 5
6' 6'
1"
7'
3'
3'
2' 6"
3" 7' 10" 8' 2"
Dining Room Height: 8'
401.24 SF Walls
600.14 SF Walls & Ceiling
22.10 SY Flooring
50.16 LF Ceil. Perimeter
198.90 SF Ceiling
198.90 SF Floor
50.16 LF Floor Perimeter
Missing Wall 8' X 8' Opens into KITCHEN
DESCRIPTION QTY
------------------ ELECTRICAL -----------------
256. R&R Switch 2.00 EA
257. R&R Light fixture 1.00 EA
258. R&R Outlet 2.00 EA
------------------ INSULATION -----------------
259. Batt insulation - 10" - R30 - paper faced 198.90 SF
------------------ WALLS & CEILINGS -----------------
260. Remove Sheathing - plywood - 1/2" - treated 198.90 SF
261. Install Sheathing - plywood - 1/2" - treated 198.90 SF
262. Material Only Sheathing - plywood - 1/2" - treated 198.90 SF
263. Seal & paint plywood sheathing 198.90 SF
264. Remove Joist - floor or ceiling - 2x6 - w/blocking - 16" oc 198.90 SF
265. Install Joist - floor or ceiling - 2x6 - w/blocking - 16" oc 198.90 SF
266. Material Only Joist - floor or ceiling - 2x6 - w/blocking - 16" oc 198.90 SF
267. Cove molding - 3/4" 50.16 LF
HOUSING ASSESSMENT in SUPPORT of Typhoon Yutu DR-4404-MP
CNMI-412600376_RA 12/25/2019 Page: 21
CONTINUED - Dining Room
DESCRIPTION QTY
------------------ DOORS & WINDOWS -----------------
268. R&R Exterior door - metal - insulated - flush or panel style 1.00 EA
269. Door lockset & deadbolt - exterior 1.00 EA
270. Paint door slab only - 2 coats (per side) 2.00 EA
Painting all 6 sides of door
271. Paint door/window trim & jamb - 2 coats (per side) 2.00 EA
NOTES:
Up
Up Closet 2 (1)
Hallway 2
G
FC
I
Closet 1 (1)
Den
Bathroom 2
Stairs
Dining Room
Pantry
Bedroom 2
Hallway
Bedroom 1
Kitchen
Living Room
Bathroom 1
Entry/Foyer
3' 2"
4'
4'
3'
3'
2' 10"
7'
Stairs Height: 17'
223.70 SF Walls
245.35 SF Walls & Ceiling
4.11 SY Flooring
7.58 LF Ceil. Perimeter
21.65 SF Ceiling
36.99 SF Floor
8.82 LF Floor Perimeter
Missing Wall 3' 2 1/4" X 17' Opens into LIVING_ROOM
Up
Up Closet 2 (1)
Hallway 2
G
FC
I
Closet 1 (1)
Den
Bathroom 2
Stairs
Dining Room
Pantry
Bedroom 2
Hallway
Bedroom 1
Kitchen
Living Room
Bathroom 1
Entry/Foyer
2' 10"
1'
4'
7'
1'
3' Subroom: Stairs2 (1) Height: 12' 6"
155.45 SF Walls
176.76 SF Walls & Ceiling
3.88 SY Flooring
15.17 LF Ceil. Perimeter
21.31 SF Ceiling
34.89 SF Floor
17.15 LF Floor Perimeter
Missing Wall 2' 9 3/4" X 12' 6" Opens into LANDING
Missing Wall 2' 11 3/4" X 12' 6" Opens into LIVING_ROOM
HOUSING ASSESSMENT in SUPPORT of Typhoon Yutu DR-4404-MP
CNMI-412600376_RA 12/25/2019 Page: 22
Up
Up
Closet 2 (1)
Hallway 2
G
FC
I
Closet 1 (1)
Den
Bathroom 2
Stairs
Dining Room
Pantry
Bedroom 2
Hallway
Bedroom 1
Kitchen
Living Room
Bathroom 1
Entry/Foyer
2' 10"
1' 5" 1' 8"
3' 10"
4' 1"
1' 4"
1' 7"
2'
"2' 10"
Subroom: Landing (2) Height: 12' 6"
142.46 SF Walls
161.02 SF Walls & Ceiling
2.06 SY Flooring
11.40 LF Ceil. Perimeter
18.57 SF Ceiling
18.57 SF Floor
11.40 LF Floor Perimeter
Missing Wall 2' 9 3/4" X 12' 6" Opens into STAIRS2
Missing Wall 2' 10 1/4" X 12' 6" Opens into STAIRS
DESCRIPTION QTY
------------------ ELECTRICAL -----------------
272. R&R Switch 1.00 EA
273. R&R Light fixture 1.00 EA
274. R&R Outlet 1.00 EA
------------------ INSULATION -----------------
275. Batt insulation - 10" - R30 - paper faced 61.53 SF
------------------ WALLS & CEILINGS -----------------
276. Remove Sheathing - plywood - 1/2" - treated 61.53 SF
277. Install Sheathing - plywood - 1/2" - treated 61.53 SF
278. Material Only Sheathing - plywood - 1/2" - treated 61.53 SF
279. Seal & paint plywood sheathing 61.53 SF
280. Remove Joist - floor or ceiling - 2x6 - w/blocking - 16" oc 61.53 SF
281. Install Joist - floor or ceiling - 2x6 - w/blocking - 16" oc 61.53 SF
282. Material Only Joist - floor or ceiling - 2x6 - w/blocking - 16" oc 61.53 SF
283. Cove molding - 3/4" 34.15 LF
------------------ FLOORING -----------------
284. Floor preparation for resilient flooring 90.45 SF
285. Remove Vinyl floor covering (sheet goods) 90.45 SF
286. Vinyl floor covering (sheet goods) 104.02 SF
15% added for waste
NOTES:
HOUSING ASSESSMENT in SUPPORT of Typhoon Yutu DR-4404-MP
CNMI-412600376_RA 12/25/2019 Page: 23
Up
Up Closet 2 (1)
Hallway 2
G
FC
I
Closet 1 (1)
Den
Bathroom 2
Stairs
Dining Room
Pantry
Bedroom 2
Hallway
Bedroom 1
Kitchen
Living Room
Bathroom 1
Entry/Foyer
4'3' 6"
4' 6"
4' 10"
' 1
0"
' 4
2' 6"
1' 2" 4' 8"
4' 10" 2' 6"
8"
4' 9"
3'
3'
4'
4'
4'
1'
1'
Bedroom 1 Height: 8'
405.33 SF Walls
565.33 SF Walls & Ceiling
17.78 SY Flooring
50.67 LF Ceil. Perimeter
160.00 SF Ceiling
160.00 SF Floor
50.67 LF Floor Perimeter
Up
Up Closet 2 (1)
Hallway 2
G
FC
I
Closet 1 (1)
Den
Bathroom 2
Stairs
Dining Room
Pantry
Bedroom 2
Hallway
Bedroom 1
Kitchen
Living Room
Bathroom 1
Entry/Foyer
2' 6"
4' 8"
4' 10"
9"2' 6"
8"
10"
4' 9"
2'
8' 2"
7' 10" 1'
2'
Subroom: Closet 1 (1) Height: 8'
153.98 SF Walls
167.76 SF Walls & Ceiling
1.53 SY Flooring
19.25 LF Ceil. Perimeter
13.78 SF Ceiling
13.78 SF Floor
19.25 LF Floor Perimeter
DESCRIPTION QTY
------------------ ELECTRICAL -----------------
287. R&R Switch 1.00 EA
288. R&R Light fixture 1.00 EA
289. R&R Outlet 3.00 EA
290. Smoke detector 1.00 EA
NOTES:
Up
Up Closet 2 (1)
Hallway 2
G
FC
I
Closet 1 (1)
Den
Bathroom 2
Stairs
Dining Room
Pantry
Bedroom 2
Hallway
Bedroom 1
Kitchen
Living Room
Bathroom 1
Entry/Foyer
3'3' 3" 4'
3' 1"1' 5" 2'
3' 2"
4'
7'
7'
1'
2' 2'
2' 6"
2' 2'
2' 6" 4' 10"
5' 2"
2' 6"
8"
' 4
Bedroom 2 Height: 8'
459.13 SF Walls
653.43 SF Walls & Ceiling
21.59 SY Flooring
57.39 LF Ceil. Perimeter
194.30 SF Ceiling
194.30 SF Floor
57.39 LF Floor Perimeter
HOUSING ASSESSMENT in SUPPORT of Typhoon Yutu DR-4404-MP
CNMI-412600376_RA 12/25/2019 Page: 24
Up
Up Closet 2 (1)
Hallway 2
G
FC
I
Closet 1 (1)
Den
Bathroom 2
Stairs
Dining Room
Pantry
Bedroom 2
Hallway
Bedroom 1
Kitchen
Living Room
Bathroom 1
Entry/Foyer
2' 6"
4' 10"
5' 2"
8" 2' 6" 4"
8"
5' 2"
2'
2'
7' 9"
7' 7"
7"
5"
2'
2'
Subroom: Closet 2 (1) Height: 8'
159.98 SF Walls
175.97 SF Walls & Ceiling
1.78 SY Flooring
20.00 LF Ceil. Perimeter
15.99 SF Ceiling
15.99 SF Floor
20.00 LF Floor Perimeter
DESCRIPTION QTY
------------------ ELECTRICAL -----------------
291. R&R Switch 1.00 EA
292. R&R Light fixture 1.00 EA
293. R&R Outlet 4.00 EA
294. Smoke detector 1.00 EA
NOTES:
Up
Up Closet 2 (1)
Hallway 2
G
FC
I
Closet 1 (1)
Den
Bathroom 2
Stairs
Dining Room
Pantry
Bedroom 2
Hallway
Bedroom 1
Kitchen
Living Room
Bathroom 1
Entry/Foyer
12'
11' 4"
2' 6"
2' 3"
2' 7"
9"
11" 2' 6"
2" 2' 10"
3' 2"
3'
Hallway Height: 8'
191.72 SF Walls
235.49 SF Walls & Ceiling
4.86 SY Flooring
23.96 LF Ceil. Perimeter
43.77 SF Ceiling
43.77 SF Floor
23.96 LF Floor Perimeter
Missing Wall 3' 9 1/16" X 8' Opens into KITCHEN
Missing Wall 3' 9 1/16" X 8' Opens into LIVING_ROOM
DESCRIPTION QTY
------------------ ELECTRICAL -----------------
295. R&R Switch 2.00 EA
296. R&R Light fixture 1.00 EA
297. R&R Outlet 3.00 EA
298. Smoke detector 1.00 EA
299. Carbon monoxide detector 1.00 EA
------------------ INSULATION -----------------
300. Batt insulation - 10" - R30 - paper faced 43.77 SF
------------------ WALLS & CEILINGS -----------------
HOUSING ASSESSMENT in SUPPORT of Typhoon Yutu DR-4404-MP
CNMI-412600376_RA 12/25/2019 Page: 25
CONTINUED - Hallway
DESCRIPTION QTY
301. Remove Sheathing - plywood - 1/2" - treated 43.77 SF
302. Install Sheathing - plywood - 1/2" - treated 43.77 SF
303. Material Only Sheathing - plywood - 1/2" - treated 43.77 SF
304. Seal & paint plywood sheathing 43.77 SF
305. Remove Joist - floor or ceiling - 2x6 - w/blocking - 16" oc 43.77 SF
306. Install Joist - floor or ceiling - 2x6 - w/blocking - 16" oc 43.77 SF
307. Material Only Joist - floor or ceiling - 2x6 - w/blocking - 16" oc 43.77 SF
308. Cove molding - 3/4" 23.96 LF
NOTES:
Up
Up Closet 2 (1)
Hallway 2
G
FC
I
Closet 1 (1)
Den
Bathroom 2
Stairs
Dining Room
Pantry
Bedroom 2
Hallway
Bedroom 1
Kitchen
Living Room
Bathroom 1
Entry/Foyer
2'
6" 8"
1'
8' 2"
7' 10"2'
1'
2' 6"
1' 2"
10" 7"
5'
1"
7' 9"
7' 7"
2' 6"1' 5"
1' 3"
Hallway 2 Height: 8'
243.33 SF Walls
298.25 SF Walls & Ceiling
6.10 SY Flooring
30.42 LF Ceil. Perimeter
54.92 SF Ceiling
54.92 SF Floor
30.42 LF Floor Perimeter
Missing Wall 5' 11 1/16" X 8' Opens into LIVING_ROOM
DESCRIPTION QTY
------------------ ELECTRICAL -----------------
309. R&R Switch 2.00 EA
310. R&R Light fixture 1.00 EA
311. R&R Outlet 3.00 EA
HOUSING ASSESSMENT in SUPPORT of Typhoon Yutu DR-4404-MP
CNMI-412600376_RA 12/25/2019 Page: 26
Up
Up
Closet 2 (1)
Hallway 2
G
FC
I
Closet 1 (1)
Den
Bathroom 2
Stairs
Dining Room
Pantry
Bedroom 2
Hallway
Bedroom 1
Kitchen
Living Room
Bathroom 1
Entry/Foyer
5'
5' 6"
5' 10"
4'
2' 6"
2' 3"
2' 7"
9"
11" Bathroom 1 Height: 8'
162.52 SF Walls
188.14 SF Walls & Ceiling
2.85 SY Flooring
20.32 LF Ceil. Perimeter
25.62 SF Ceiling
25.62 SF Floor
20.32 LF Floor Perimeter
DESCRIPTION QTY
------------------ ELECTRICAL -----------------
312. R&R Bathroom ventilation fan 1.00 EA
313. R&R Switch 2.00 EA
314. R&R Light fixture 1.00 EA
315. R&R Ground fault interrupter (GFI) outlet 1.00 EA
------------------ INSULATION -----------------
316. Batt insulation - 10" - R30 - paper faced 25.62 SF
------------------ WALLS & CEILINGS -----------------
317. Remove Sheathing - plywood - 1/2" - treated 25.62 SF
318. Install Sheathing - plywood - 1/2" - treated 25.62 SF
319. Material Only Sheathing - plywood - 1/2" - treated 25.62 SF
320. Seal & paint plywood sheathing 25.62 SF
321. Remove Joist - floor or ceiling - 2x6 - w/blocking - 16" oc 25.62 SF
322. Install Joist - floor or ceiling - 2x6 - w/blocking - 16" oc 25.62 SF
323. Material Only Joist - floor or ceiling - 2x6 - w/blocking - 16" oc 25.62 SF
324. Cove molding - 3/4" 20.32 LF
NOTES:
Up
Up Closet 2 (1)
Hallway 2
G
FC
I
Closet 1 (1)
Den
Bathroom 2
Stairs
Dining Room
Pantry
Bedroom 2
Hallway
Bedroom 1
Kitchen
Living Room
Bathroom 1
Entry/Foyer
2'
3'
1" 7'
1"
8'
2' 8" 2' 11"
1'2' 5"
2' 9"
2' 10"
3'
1'
" 5'
2'
6" 8"
1'
2' 2' 3'
1' 7"
Bathroom 2 Height: 8'
300.12 SF Walls
391.48 SF Walls & Ceiling
10.15 SY Flooring
37.51 LF Ceil. Perimeter
91.36 SF Ceiling
91.36 SF Floor
37.51 LF Floor Perimeter
HOUSING ASSESSMENT in SUPPORT of Typhoon Yutu DR-4404-MP
CNMI-412600376_RA 12/25/2019 Page: 27
CONTINUED - Bathroom 2
DESCRIPTION QTY
------------------ ELECTRICAL -----------------
325. R&R Switch 1.00 EA
326. R&R Light fixture 1.00 EA
327. R&R Ground fault interrupter (GFI) outlet 1.00 EA
328. R&R Bathroom ventilation fan 1.00 EA
NOTES:
Up
Up Closet 2 (1)
Hallway 2
G
FC
I
Closet 1 (1)
Den
Bathroom 2
Stairs
Dining Room
Pantry
Bedroom 2
Hallway
Bedroom 1
Kitchen
Living Room
Bathroom 1
Entry/Foyer
2' 6" 10"
3' 5"
2' 6"
3' 6"
9"
4'
4'
3' 1' 10"1' 11"
2' 3"
4'
0"
Entry/Foyer Height: 8'
177.62 SF Walls
206.94 SF Walls & Ceiling
3.26 SY Flooring
22.20 LF Ceil. Perimeter
29.33 SF Ceiling
29.33 SF Floor
22.20 LF Floor Perimeter
DESCRIPTION QTY
------------------ ELECTRICAL -----------------
329. R&R Switch 3.00 EA
330. R&R Light fixture 1.00 EA
------------------ INSULATION -----------------
HOUSING ASSESSMENT in SUPPORT of Typhoon Yutu DR-4404-MP
CNMI-412600376_RA 12/25/2019 Page: 28
Up
Up
Closet 2 (1)
Hallway 2
G
FC
I
Closet 1 (1)
Den
Bathroom 2
Stairs
Dining Room
Pantry
Bedroom 2
Hallway
Bedroom 1
Kitchen
Living Room
Bathroom 1
Entry/Foyer
5' 6"
5' 8"
5'
4'
2' 6"
2"
4"
2' 10"
3' 2" Pantry Height: 8'
162.29 SF Walls
187.84 SF Walls & Ceiling
2.84 SY Flooring
20.29 LF Ceil. Perimeter
25.55 SF Ceiling
25.55 SF Floor
20.29 LF Floor Perimeter
DESCRIPTION QTY
------------------ ELECTRICAL -----------------
331. R&R Switch 1.00 EA
332. R&R Light fixture 1.00 EA
333. R&R Outlet 2.00 EA
------------------ INSULATION -----------------
334. Batt insulation - 10" - R30 - paper faced 25.55 SF
------------------ WALLS & CEILINGS -----------------
335. Remove Sheathing - plywood - 1/2" - treated 25.55 SF
336. Install Sheathing - plywood - 1/2" - treated 25.55 SF
337. Material Only Sheathing - plywood - 1/2" - treated 25.55 SF
338. Seal & paint plywood sheathing 25.55 SF
339. Remove Joist - floor or ceiling - 2x6 - w/blocking - 16" oc 25.55 SF
340. Install Joist - floor or ceiling - 2x6 - w/blocking - 16" oc 25.55 SF
341. Material Only Joist - floor or ceiling - 2x6 - w/blocking - 16" oc 25.55 SF
342. Cove molding - 3/4" 20.29 LF
NOTES:
2nd Floor 2nd Floor
DESCRIPTION QTY
------------------ ELECTRICAL -----------------
343. Rewire - average residence - copper wiring 1141.58 SF
------------------ WALL REPAIRS-----------------
344. Wedge anchor bolt - 1/2" x 8 1/2" 145.00 EA
For cold joint between top of wall and new bond beam.
345. Epoxy crack and joint filler (per LF of crack) 145.00 LF
HOUSING ASSESSMENT in SUPPORT of Typhoon Yutu DR-4404-MP
CNMI-412600376_RA 12/25/2019 Page: 29
CONTINUED - 2nd Floor
DESCRIPTION QTY
NOTES:
Bedroom 2
Hallway Bathroom
Closet 2 (1)
Bedroom 1
Stairwell
Living Room
Closet 1 (1)
' 1
0"
' 2
7' 6" 5' 7" 9"
5'
1"
' 1 0"
' 4
6'
1"
7'
3'
5'
2' 5" 2' 7"
2' 4"
3'
2' 2"
Living Room Height: 8'
620.39 SF Walls
1148.28 SF Walls & Ceiling
58.65 SY Flooring
77.55 LF Ceil. Perimeter
527.89 SF Ceiling
527.89 SF Floor
77.55 LF Floor Perimeter
Missing Wall 5' 6 1/2" X 8' Opens into STAIRWELL
Missing Wall 5' 11 1/16" X 8' Opens into HALLWAY
Bedroom 2
Hallway
Bathroom
Closet 2 (1)
Bedroom 1
Stairwell
Living Room
Closet 1 (1)
5' 10"
7"
6"
10" 5"
2'
1'
1"
2"
7' 6"
2'
Subroom: Room2 (2) Height: 8'
92.28 SF Walls
107.63 SF Walls & Ceiling
1.71 SY Flooring
11.53 LF Ceil. Perimeter
15.35 SF Ceiling
15.35 SF Floor
11.53 LF Floor Perimeter
Missing Wall 7' 6 7/16" X 8' Opens into LIVING_ROOM2
Bedroom 2
Hallway
Bathroom
Closet 2 (1)
Bedroom 1
Stairwell
Living Room
Closet 1 (1)
1' 2"
6"
4"
4'
4'
1' 6"
2"
4'
4'
Subroom: Room5 (1) Height: 8'
79.98 SF Walls
86.26 SF Walls & Ceiling
0.70 SY Flooring
10.00 LF Ceil. Perimeter
6.28 SF Ceiling
6.28 SF Floor
10.00 LF Floor Perimeter
Missing Wall 1' 6 1/8" X 8' Opens into LIVING_ROOM2
------------------ ELECTRICAL -----------------
HOUSING ASSESSMENT in SUPPORT of Typhoon Yutu DR-4404-MP
CNMI-412600376_RA 12/25/2019 Page: 30
CONTINUED - Living Room
DESCRIPTION QTY
346. R&R Switch 2.00 EA
347. R&R Light fixture 3.00 EA
348. R&R Outlet 4.00 EA
------------------ INSULATION -----------------
349. Batt insulation - 10" - R30 - paper faced 549.51 SF
------------------ WALLS & CEILINGS -----------------
350. Remove Sheathing - plywood - 1/2" - treated 549.51 SF
351. Install Sheathing - plywood - 1/2" - treated 549.51 SF
352. Material Only Sheathing - plywood - 1/2" - treated 549.51 SF
353. Seal & paint plywood sheathing 549.51 SF
354. Remove Joist - floor or ceiling - 2x6 - w/blocking - 16" oc 549.51 SF
355. Install Joist - floor or ceiling - 2x6 - w/blocking - 16" oc 549.51 SF
356. Material Only Joist - floor or ceiling - 2x6 - w/blocking - 16" oc 549.51 SF
357. Cove molding - 3/4" 99.08 LF
------------------ FLOORING -----------------
358. Floor preparation for resilient flooring 549.51 SF
359. Remove Vinyl floor covering (sheet goods) 549.51 SF
360. Vinyl floor covering (sheet goods) 631.94 SF
15% added for waste
NOTES:
Bedroom 2
Hallway
Bathroom
Closet 2 (1)
Bedroom 1
Stairwell
Living Room
Closet 1 (1)
4'4' 1"
3' 11"
4' 3"
' 1
0"
' 4
2' 6"
1' 3" 5" 7' 10"
8' 3'
3'
4'
4'
1'
0"
1'
Bedroom 1 Height: 8'
405.33 SF Walls
565.33 SF Walls & Ceiling
17.78 SY Flooring
50.67 LF Ceil. Perimeter
160.00 SF Ceiling
160.00 SF Floor
50.67 LF Floor Perimeter
HOUSING ASSESSMENT in SUPPORT of Typhoon Yutu DR-4404-MP
CNMI-412600376_RA 12/25/2019 Page: 31
Bedroom 2
Hallway
Bathroom
Closet 2 (1)
Bedroom 1
Stairwell
Living Room
Closet 1 (1)7' 10"
8'
2'
8' 2"
1'
2'
Subroom: Closet 1 (1) Height: 8'
153.98 SF Walls
167.76 SF Walls & Ceiling
1.53 SY Flooring
19.25 LF Ceil. Perimeter
13.78 SF Ceiling
13.78 SF Floor
19.25 LF Floor Perimeter
DESCRIPTION QTY
------------------ ELECTRICAL -----------------
361. R&R Switch 1.00 EA
362. R&R Light fixture 1.00 EA
363. R&R Outlet 4.00 EA
364. Smoke detector 1.00 EA
------------------ INSULATION -----------------
365. Batt insulation - 10" - R30 - paper faced 173.78 SF
------------------ WALLS & CEILINGS -----------------
366. Remove Sheathing - plywood - 1/2" - treated 173.78 SF
367. Install Sheathing - plywood - 1/2" - treated 173.78 SF
368. Material Only Sheathing - plywood - 1/2" - treated 173.78 SF
369. Seal & paint plywood sheathing 173.78 SF
370. Remove Joist - floor or ceiling - 2x6 - w/blocking - 16" oc 173.78 SF
371. Install Joist - floor or ceiling - 2x6 - w/blocking - 16" oc 173.78 SF
372. Material Only Joist - floor or ceiling - 2x6 - w/blocking - 16" oc 173.78 SF
373. Cove molding - 3/4" 69.91 LF
------------------ A/C OPENING -----------------
374. Install 2" x 4" lumber - treated (.667 BF per LF) 10.00 LF
To fill A/C Hole in exterior wall
375. Material Only 2" x 4" lumber - treated (.667 BF per LF) 10.00 LF
To fill A/C Hole in exterior wall
376. Install Sheathing - plywood - 3/4" - treated 8.00 SF
377. Material Only Sheathing - plywood - 3/4" - treated 8.00 SF
378. Seal & paint plywood sheathing 8.00 SF
To paint A/C Hole in exterior wall
------------------ FLOORING -----------------
379. Floor preparation for resilient flooring 173.78 SF
380. Remove Vinyl floor covering (sheet goods) 173.78 SF
381. Vinyl floor covering (sheet goods) 199.85 SF
15% added for waste
HOUSING ASSESSMENT in SUPPORT of Typhoon Yutu DR-4404-MP
CNMI-412600376_RA 12/25/2019 Page: 32
CONTINUED - Bedroom 1
DESCRIPTION QTY
NOTES:
Bedroom 2
Hallway
Bathroom
Closet 2 (1)
Bedroom 1
Stairwell
Living Room
Closet 1 (1)
2' 11"3' 3" 4'
3'1' 7" 3' 2"
4'
5'
5'
4'
4'
2' 2'
2' 6"
2' 2'
8' 8' 4"
' 4
Bedroom 2 Height: 8'
459.30 SF Walls
653.70 SF Walls & Ceiling
21.60 SY Flooring
57.41 LF Ceil. Perimeter
194.40 SF Ceiling
194.40 SF Floor
57.41 LF Floor Perimeter
Bedroom 2
Hallway
Bathroom
Closet 2 (1)
Bedroom 1
Stairwell
Living Room
Closet 1 (1)
8'
8' 4"
2'
2'
7' 9"
7' 7"
7"
5"
2'
2'
Subroom: Closet 2 (1) Height: 8'
159.98 SF Walls
175.97 SF Walls & Ceiling
1.78 SY Flooring
20.00 LF Ceil. Perimeter
15.99 SF Ceiling
15.99 SF Floor
20.00 LF Floor Perimeter
DESCRIPTION QTY
------------------ ELECTRICAL -----------------
382. R&R Switch 1.00 EA
383. R&R Light fixture 1.00 EA
384. R&R Outlet 3.00 EA
385. Smoke detector 1.00 EA
------------------ INSULATION -----------------
386. Batt insulation - 10" - R30 - paper faced 210.38 SF
------------------ WALLS & CEILINGS -----------------
387. Remove Sheathing - plywood - 1/2" - treated 210.38 SF
388. Install Sheathing - plywood - 1/2" - treated 210.38 SF
389. Material Only Sheathing - plywood - 1/2" - treated 210.38 SF
390. Seal & paint plywood sheathing 210.38 SF
HOUSING ASSESSMENT in SUPPORT of Typhoon Yutu DR-4404-MP
CNMI-412600376_RA 12/25/2019 Page: 33
CONTINUED - Bedroom 2
DESCRIPTION QTY
391. Remove Joist - floor or ceiling - 2x6 - w/blocking - 16" oc 210.38 SF
392. Install Joist - floor or ceiling - 2x6 - w/blocking - 16" oc 210.38 SF
393. Material Only Joist - floor or ceiling - 2x6 - w/blocking - 16" oc 210.38 SF
394. Cove molding - 3/4" 77.41 LF
------------------ FLOORING -----------------
395. Floor preparation for resilient flooring 210.38 SF
396. Remove Vinyl floor covering (sheet goods) 210.38 SF
397. Vinyl floor covering (sheet goods) 241.94 SF
15% added for waste
NOTES:
Bedroom 2
Hallway
Bathroom
Closet 2 (1)
Bedroom 1
Stairwell
Living Room
Closet 1 (1)
2'
3'
1" 7'
1"
8'
2' 11"
1'2' 4"
2' 10"
2' 11"
3'
1'
3'
0" 2'
' 1
1"
2'
2' 3"
2'
Bathroom Height: 8'
300.12 SF Walls
391.48 SF Walls & Ceiling
10.15 SY Flooring
37.51 LF Ceil. Perimeter
91.36 SF Ceiling
91.36 SF Floor
37.51 LF Floor Perimeter
DESCRIPTION QTY
------------------ ELECTRICAL -----------------
398. R&R Switch 1.00 EA
399. R&R Light fixture 1.00 EA
400. R&R Ground fault interrupter (GFI) outlet 1.00 EA
------------------ INSULATION -----------------
401. Batt insulation - 10" - R30 - paper faced 91.36 SF
------------------ WALLS & CEILINGS -----------------
402. Remove Sheathing - plywood - 1/2" - treated 91.36 SF
403. Install Sheathing - plywood - 1/2" - treated 91.36 SF
404. Material Only Sheathing - plywood - 1/2" - treated 91.36 SF
HOUSING ASSESSMENT in SUPPORT of Typhoon Yutu DR-4404-MP
CNMI-412600376_RA 12/25/2019 Page: 34
CONTINUED - Bathroom
DESCRIPTION QTY
405. Seal & paint plywood sheathing 91.36 SF
406. Remove Joist - floor or ceiling - 2x6 - w/blocking - 16" oc 91.36 SF
407. Install Joist - floor or ceiling - 2x6 - w/blocking - 16" oc 91.36 SF
408. Material Only Joist - floor or ceiling - 2x6 - w/blocking - 16" oc 91.36 SF
409. Cove molding - 3/4" 37.51 LF
NOTES:
Bedroom 2
Hallway
Bathroom
Closet 2 (1)
Bedroom 1
Stairwell
Living Room
Closet 1 (1)
3'
0"
4'
8' 2"
7' 10"2'
1'
2' 6"
1' 3"
11" 7"
5'
1"
7' 9"
7' 7"
2' 6" 1' 1"10"
8"
Hallway Height: 8'
243.33 SF Walls
298.25 SF Walls & Ceiling
6.10 SY Flooring
30.42 LF Ceil. Perimeter
54.92 SF Ceiling
54.92 SF Floor
30.42 LF Floor Perimeter
Missing Wall 5' 11 1/16" X 8' Opens into LIVING_ROOM2
DESCRIPTION QTY
------------------ ELECTRICAL -----------------
410. R&R Switch 1.00 EA
411. R&R Light fixture 1.00 EA
412. R&R Outlet 1.00 EA
413.
This is the start of the file's text. The full file is on GovTribe.