This is an architectural drawing document containing exterior elevation plans for Building 401 of the Mount Weather Emergency Operations Center in Mount Weather, Virginia. The sheet (A2.02) illustrates multiple elevation views at 1/4" = 1'-0" and 1/2" = 1'-0" scales, showing the building's facade design across four levels with a roof structure reaching approximately 1783' above grade.
The elevations specify construction materials and systems including field brick (BRK-1) in running bond masonry pattern, accent brick (BRK-2) in various patterns (running bond, soldier course, and stacked bond), and caststone concrete sills (PCC-1, PCC-2, PCC-3). Additional architectural elements include standing seam metal roof panels (SMR), cold-formed metal eave and fascia systems with and without gutters (MEF-1, MEF-2), snow retention rail systems in slate gray, metal panel systems in slate grey, downspouts, handrails, and custom metal agency seal medallions. The document includes general notes requiring all projecting masonry units to be solid core and specifying a mock-up of the exterior brick wall to verify selections and demonstrate aesthetic effects. The drawing is marked as Unclassified/For Official Use Only and includes submission date of 07/28/20 with sheet number A2.02 from a multi-sheet set of 136 sheets.
View the file
Other files
Show all 31
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LEVEL 2 FF
1716' - 0"
LEVEL 3 FF
1730' - 8"
LEVEL 4 FF
1745' - 4"
LEVEL 5 ATTIC
1760' - 0"
5 64 7
LEVEL 4 TOS
1744' - 4"
LEVEL 3 TOS
1729' - 8"
LEVEL 2 TOS
1715' - 0"
A1.00A3.12
MCA
EQ EQ
A2.02A5.03
TYP 5
6 PCC-2
5 4
PCC-1
BR-2
7 7
PCC-1
PCC-1
DS
7 7
PCC-1 BR-2
PCC-1 PCC-1
13 12 99 PCC-24 4
DS
MEF-2
LEVEL 3 FF
1730' - 8"
LEVEL 4 FF
1745' - 4"
LEVEL 5 ATTIC
1760' - 0"
56 47
LEVEL 4 TOS
1744' - 4"
A1.00A3.11
PCC-2
PCC-2
EQEQ
A2.02A5.03
TYP
13 12 99 PCC-2 17
PCC-2
DS
MEF-2
7 4 7 4
PCC-2 PCC-2
DS
MCA
BRICK FIELD WITH
MORTAR 1
ABBREVIATIONS - ELEV.
BRK-1
BRICK ACCENT WITH
MORTAR 2
BRK-2
CASTSTONE CONCRETE
SILL - PCC-1
PCC-1
COLD FORMED METAL EAVE &
FASCIA SYSTEM - MATCH ROOF
MEF-1
COLD FORMED METAL EAVE &
FASCIA SYSTEM W/ GUTTER -
MATCH ROOF
MEF-2
SNOW RETENTION RAIL
SYSTEM - COLOR - SLATE GRAY
SRRS
6X6 DOWN SPOUTDS
VERTICAL MASONRY CONTROL
JOINT SEE 11/A5.10
MCJ
METAL CANOPY MCA
METAL PANEL SYSTEM -
COLOR SLATE GREY
FMWP-1
CASTSTONE CONCRETE
SILL - PCC-2
PCC-2
CASTSTONE CONCRETE
SILL - PCC-3
PCC-3
METAL EAVE AND FASCIA
SYSTEM W/OUT GUTTER
MEF-1
METAL EAVE AND FASCIA
SYSTEM W/ GUTTER
MEF-2
STANDING SEAM METAL
ROOF PANELS
SMR
KEYNOTES - ELEV.
FIELD BRICK (BRK-1) - RUNNING BOND
MASONRY PATTERN, TYP
FIELD BRICK (BRK-1) - SOLDIER COURSE
AT WINDOW HEADER
FIELD BRICK (BRK-1) - STRETCHER
COURSE AT TOP OF GABLE
ACCENT BRICK (BRK-2) - RUNNING BOND
MASONRY PATTERN
ACCENT BRICK (BRK-2) - STACKED BOND
MASONRY PATTERN
ACCENT BRICK (BRK-2) - RUNNING BOND
WITH BANDED CORBEL MASONRY
PATTERN
ACCENT BRICK (BRK-2) SOLDIER
COURSE AT WINDOW HEADER
MASS NOTIFICATION SPEAKER
DOWNSPOUT BOOT , TYPICAL
HANDRAIL
STANDING SEAM METAL ROOF PANELS,
SEE SHEET A1.06 FOR ROOF PATTERN
DIAGRAM
CUSTOM MTL. AGENCY SEAL
MEDALLION;
SEE 1/ A7.09
BUILDING ADDRESS SIGNAGE:
- MTL . DYE CUT LETTERS
- HEIGHT: 12"
- FONT: JOANNA MT
BOILER STACK SEE MECH.
SIAMESE FDC & TEST HEAD, SEE CIVIL
GRADE LINE - 18 FEET OFFSET
ADA DOOR OPERATOR ON STAINLESS
STL PEDESTAL
SNOW RETENTION RAIL SYSTEM (SRRS)
WALL HYDRANT
CONCRETE BRICK SHELF
CANOPY TIE RODS WITH ROUND
ESCUTCHEON PLATES
LEVEL 2 FF
1716' - 0"
LEVEL 3 FF
1730' - 8"
LEVEL 4 FF
1745' - 4"
LEVEL 5 ATTIC
1760' - 0"
CB
LEVEL 4 TOS
1744' - 4"
LEVEL 3 TOS
1729' - 8"
T.O. ROOF
1783' - 0"
A1.00A3.10
MEF-1
PCC-1
PCC-2
PCC-2
PCC-1
L1
EQ EQ
8 ALIGN
PCC-2
PCC-2
PCC-2
PCC-2
6' - 0"
1' - 4" 2' - 0" 1' - 4" 1' - 4"
NOTE:
BUILD MOCK UP OF EXTERIOR BRICK WALL TO VERIFY SELECTIONS
MADE UNDER THE SAMPLE SUBMITTALS, TO DEMONSTRATE AESTHETIC
EFFECTS, AND TO SET QUALITY STANDARDS FOR MATERIAL AND EXECUTION.
GL-6 /
DGF-1
GL-8
PCC-1
PROJECT NO:
DESIGNED BY:
DRAWN BY:
APPROVED BY:
EPS NO:
SHEET
WORK ORDER NO:
OF
M O
U N
T W
E A
T H
E R
E M
E R
G E
N C
Y O
P E
R A
T
IO
N S
C E
N T
E R
M O
U N
T W
E A
T H
E R
, V
IR
G
IN
IA
-2
SHEET TITLE:
IS
S
U E
B
LO
C K
UNCLASSIFIED / FOR OFFICIAL USE ONLY
UNCLASSIFIED / FOR OFFICIAL USE ONLY
CHECKED BY:
A2.02
ELEVATIONS
CLP
CSM
CSM
2019427.00
738785
BUILDING 401
B U
IL
D
IN
G
GRK
IFC
SUBMISSION
07/28/20
1/4" = 1'-0"A2.02A2.00
ENLARGED ELEVATION3
1/4" = 1'-0"A2.02A2.01
ENLARGED ELEVATION1
1/4" = 1'-0"A2.02A2.00
ENLARGED ELEVATION2
1/2" = 1'-0"A2.02
ENLARGED ELEVATION - MOCK UP4
1. ALL MASONRY UNITS THAT PROJECT PAST
THE FACE OF THE BUILDING SHALL BE SOILD
CORE UNITS.
2. SEE FLOOR PLANS FOR GLAZING TYPES,
TYPICAL
3. SEE SHEET A5.03 FOR PRECAST STONE
PROFILES.
GENERAL NOTES -
EXTERIOR ELEVATIONS
M A
R K
D A
T E
D E
S C
R
IP
T
IO
N B
Y