This document is an architectural floor plan for Level 2 of Building 401 at Mount Weather Emergency Operations Center in Mount Weather, Virginia. The plan is drawn at a scale of 1/8" = 1'-0" and is marked as UNCLASSIFIED / FOR OFFICIAL USE ONLY, submitted by FEMA as part of an IFC (Issued For Construction) submission dated July 28, 2020.

The floor plan details the layout of Level 2, which includes multiple functional spaces such as a lobby (Room 200), telephone room (Room 202), mechanical room (Room 207), break room (Room 208), electrical room (Room 205), corridors, stairwells, elevators, and multiple future tenant spaces (Rooms 210-211). The plan incorporates detailed keynotes and specifications for building components including fire extinguisher cabinets (surface-mounted, semi-recessed, and fully recessed), floor drains, glazing types with film applications, door operators, drinking fountains, recycle bins, AED cabinets, and utility shafts. Dimensions are provided throughout, with room widths ranging from 9'6" to 25'1 3/4". The document includes a comprehensive legend identifying symbols for partitions, swing doors and frames, raised access floors, and various mechanical and electrical notations, along with references to related drawing sheets for detailed specifications such as telecom backing requirements and storefront glazing details.

View the file

Other files

File Type Posted
PP_Questionnaire.docx DOCX document
B401Tele Room 102 - 202 - pathway and Rack elevations.pdf PDF
101423.001.00 - Interior Signage.pdf PDF
B401 Base Bldg A6.20 Window Schedule & Details.pdf PDF
B401 Base Bldg A2.02 Window Elevations.pdf PDF
Level-2 Mech Piping Plan Existing.pdf PDF
70FA5026Q00000001 A0002.pdf PDF
Copy of B401 Tenant-6 Bidder Inquiries - 021326 REV-6 FINAL to post.xlsx XLSX spreadsheet
101423.002.00 - Interior Signage -SAMPLE-2.pdf PDF
B401 T6 Bre-Bid Conference Sign in Sheet.pdf PDF
101423 Signage spec from Tenant 1 and 2.pdf PDF
B401 Base Bldg A2.00 Window Elevations.pdf PDF
101423.001.00 - Interior Signage -SAMPLE-1.pdf PDF
Level-2 Power Plan Existing.pdf PDF
OF 336 70FA5026Q00000002.pdf PDF
265219.001.00 - Emergency and Exit Lighting - SAMPLE SUBMITTAL MWEOC Std..pdf PDF
B401 Base Bldg A2.01 Window Elevations.pdf PDF
GFCI Government Furnished Contractor Installed Materials.pdf PDF
70FA5026Q00000002 A0001.pdf PDF
B401 T6 IFC FFE Spec Book.pdf PDF
B401 Tenant 6 Vol I-II IFC Specifications.pdf PDF
B401 Tenant6 Dry Cooler IFC Plans - Combined.pdf PDF
B401 T6 IFC FFE Plan Schedules1.pdf PDF
Previous Bidder Inquiries QA Ref Only 12.08.25 REV6.pdf PDF
B401 Base-Building Subcontractor List.docx DOCX document
70FA5026Q00000002 final.pdf PDF
B401 Base-Building MECH Dwgs.pdf PDF
283113.003.01 - Digital Addressable Fire-Alarm System - SD - AAN 2nd Floor Buildout.pdf PDF
283113 - Digital Addressable Fire Alarm - Tenant 3 4 - 10-3-23 FEMA APP w comments.pdf PDF
GFCI Government Furnished Contractor Installed Materials.docx DOCX document
70FA5026Q00000002 solicitation.pdf PDF
Show all 31

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FE-3

FE-4

FD

F E

-1

FE-1

F E

-1

F E

-1

FE-1

FE-1 FE-1

FE-1

A B

C

FE-1

FD

FE-1

A2.00

A

D

3 5 8 92 6

C

B

HSKPG

TELE RM

LOBBY

MECH RM

9' - 6" 13' - 4" 20' - 0" 15' - 0" 12' - 4" 18' - 0" 12' - 4" 15' - 0" 20' - 0" 13' - 4" 9' - 6"

BREAK RM

/4

/4

/4

/4

ELEC

A2.01

STAIR

ELEV 1

ELEV 2

4 7

2A

1.5 9.5

03B

210A

02B

A.5

C.5

A

B

A1.01 A4.00

A1.00A3.10 A1.01 VT1.01

1C

2A

A1.00A3.12

2B2B 2B 2B 2B 2B 2B 2B

2B

A1.00 A4.06

A4.08 1

A1.00A3.11

01B

A1.00A3.11

A2.00

A2.01

W1

W1 W1 W1 W1 W1

W1

W1 W1W1 W1 W1

W1

W1

W1

B

CORRIDOR

2A

6E

2A

2B

A1.01 A4.02

A1.01 A4.01

DSDSDSDS

1C

A4.07

A1.01 A5.01

A1.01 A5.01

A1.01 A5.30

A1.00 A5.01

A1.01 A4.10

A1.01 A4.10

A4.07 4

A1.00 A1.30

A1.01 A5.01

2B

A1.00A3.10

A1.01 A5.01

1' - 6"

A1.00A3.12

3SF-3

SF-4

B

A

VEST

200A

A1.01 A6.10

LEVEL 2 FUTURE

TENANT

LEVEL 2 FUTURE

TENANT

211D

2B

2B

2B 6F

2B2B

2B

2B

2B

2B

2B2B 2B 2B2B 2B 2B2B 2B 2B2B 2B 2B2B 2B 2B2B

2B

2B 2B2B 2B 2B2B 2B 2B2B 2B2B

2B

2B

2B

2B 6F

2B2B

2B

2B 2B 2B2B

2B2B2B2B2B2B2B2B2B2B2B2B2B2B2B2B2B2B2B2B

2B2B

2B2B

2B

2B2B 6F

2B

2B

2B

2B2B

2B

2B2B2B

22A

2A

3C

3C

2A

2A

6C

1C 2D2D 2A

2B 2B2B 2B2B

2B2B

2A

6F

24 4

2A

3D

W1

W1

W1

W1W1

OH

A1.01 A5.01

1716' - 0" 1716' - 0"

TO FF TO FF

TOSTOS

1716' - 0"

TO FF

TOS

1715' - 0"

TOS

1715' - 0"

TO FF

1716' - 0"

211C

2B

2A 22

2B

1C

1C

6C

6B

2A

GL-6

DGF-1

GL-6

DGF-1

GL-6

DGF-1

GL-6

DGF-1

GL-6

DGF-1

GL-6

DGF-1

GL-6

DGF-1

GL-6

DGF-1

GL-6

DGF-1

GL-6

DGF-1

GL-6

DGF-1

GL-6

DGF-1 GL-6

DGF-1

GL-6

DGF-1

GL-6

DGF-1

GL-6

DGF-1

GL-6

DGF-1

GL-6

DGF-1

GL-6

DGF-1

GL-6

DGF-1

W1

W1

GL-6

DGF-1

GL-6

DGF-1

2 2 2 2

22222

A1.00A3.12

A1.00A3.11

STAIR

STAIR

C O

R R

ID

O

R

TOILET RM

TOILET RM

LEVEL 2 FUTURE

TENANT

A4.083 4

OH

A1.01 A1.30

A1.01 A1.30

A1.01 A5.01

A1.01 A5.01

TYP

TYP

A1.01 A5.01

6 TYP

DS DS

A1.01A5.04

GL-1

DGF-2

SEE STOREFRONT SHEET FOR

EXTENT OF GLAZING FILM

1 1

A1.01 A1.30

6 A1.01 A6.35

1716' - 0"

GRADE LINE

SEE CIVIL

2B

A1.00A3.10

A1.00A3.10

A1.01A5.04

SWING DOOR AND FRAME

PARTITION

EXTENT OF RAISED

ACCESS FLOOR

LEGEND

FD FLOOR DRAIN

FE-1 FIRE EXTINGUISHER

CABINET - SURFACE

MOUNTED

FE-2 FIRE EXTINGUISHER

CABINET - SEMI

RECESSED

FE-3 FIRE EXTINGUISHER

CABINET - FULLY

RECESSED

FE-4 FIRE EXTINGUISHER

BRACKET - SURFACE

MOUNTED

DS 6X6 DOWN SPOUT

GL-6

DGF-1

GLAZING TYPE

GLAZING FILM TYPE

RECESSED WALK OFF MATT

WALL MOUNTED ADA DOOR OPERATOR

36" AFF

ADA DOOR OPERATOR ON STAINLESS

STL PEDESTAL

NOT USED

CANOPY

CELL PHONE LOCKERS, SEE EQUIP

SCHEDULE ON SHEET A1.30

ACCESS PANEL 30"X48"

UTILITY SHAFT - SEAL SHAFT ON TOP

AND BOTTOM (SEE ENLARGED PLANS ON

A4.10)

WALL MOUNTED MONITOR, SEE EQUIP

SCHEDULE ON SHEET A1.30

NOT USED

NOT USED

DRINKING FOUNTAIN; SEE SHEET A4.06

FOR MOUNTING HEIGHT

RECYCLE BINS (GFGI-OWNER), SEE

EQUIP SCHEDULE ON SHEET A1.30

AED CABINET

FLOOR DRAIN. SEE PLUMBING

DRAWINGS

NOT USED

NOT USED

PERFORATED FOUNDATION DRAIN

BELOW

WP-1 & DRAINAGE BOARD BENEATH

GRADE

TRENCHED FLOOR SLAB W/ MTL

GRATING FOR FUEL OIL PIPING - SEE

MECHANICAL/ STRUCTURAL

KEYNOTES

PROJECT NO:

DESIGNED BY:

DRAWN BY:

APPROVED BY:

EPS NO:

SHEET

WORK ORDER NO:

OF

M O

U N

T W

E A

T H

E R

E M

E R

G E

N C

Y O

P E

R A

T

IO

N S

C E

N T

E R

M O

U N

T W

E A

T H

E R

, V

IR

G

IN

IA

-2

SHEET TITLE:

IS

S

U E

B

LO

C K

UNCLASSIFIED / FOR OFFICIAL USE ONLY

UNCLASSIFIED / FOR OFFICIAL USE ONLY

CHECKED BY:

A1.01

FLOOR PLAN - LEVEL 2

CLP

CSM

CSM

2019427.00

738785

BUILDING 401

B U

IL

D

IN

G

GRK

IFC

SUBMISSION

07/28/20

1/8" = 1'-0"A1.01

FLOOR PLAN - LEVEL 21

SEE TELECOM DRAWINGS FOR EXTENT OF

PLYWOOD BACKING IN TELECOM ROOMS

1.

GENERAL NOTES

4'0 8' 16'

SCALE: 1/8" = 1'-0"

PLAN NORTH

COMPASS

NORTH

M A

R K

D A

T E

D E

S C

R

IP

T

IO

N B

Y

File details come from the government source that posted it. Updated .