Interthane 990 Marine.pdf
PDF 189 KB Posted
- Solicitation number
- 6933A220Q000005
About this file
This document includes a technical product specification sheet and a related federal contract opportunity notice.
The product specification sheet provides details for Interthane 990 Marine, a two-part acrylic polyurethane marine coating. Product information includes intended uses, colors available, application methods, surface preparation requirements, limitations, and certifications. The coating requires application over a recommended primer and has specifications for minimum and maximum overcoating intervals.
The related federal contract opportunity is a solicitation notice for drydocking repairs and an ABS intermediate survey of the T.S. KENNEDY training ship. Work includes hull blasting and coating, tank cleaning, propeller and stern tube work, and structural repairs. The period of performance is from March 1 to May 1, 2020. A site visit will be held on December 17, 2019 and questions are due by December 20th. The complete solicitation will be posted on or around December 6th. Minority, women-owned, and disadvantaged businesses are encouraged to consider the opportunity.
View the file
Other files
Show 40 more
Latest 50 of 68 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A two pack, acrylic polyurethane finish giving excellent durability and long term recoatability.PRODUCT DESCRIPTION
As a cosmetic finish on above water areas. Suitable for use on topsides, external superstructure, external decks and boottops.
For use at Newbuilding, Maintenance & Repair or On Board Maintenance.
INTENDED USES
PHB000-White, PHY999-Black ; and a wide range of colors.
57% ±3% (ISO 3233:1998)
2 mils dry (3.5 mils wet)
457 ft²/US gal at 2 mils dft, allow appropriate loss factors
Airless Spray, Brush, Conventional Spray, Roller
PRODUCT INFORMATION
Volume Solids
Typical Film Thickness
Theoretical Coverage
Method of Application
Finish/Sheen High Gloss
Part B (Curing Agent) PHA046
Mix Ratio 6.00 volume(s) Part A to 1 volume(s) Part B
Flash Point Part A 93°F; Part B 120°F; Mixed 95°F
Induction Period Not required
Overcoating Data - see limitations Substrate Temperature
Color
Drying Information 23°F 41°F 77°F 95°F
Touch Dry [ISO 9117/3:2010] 8 hrs 5 hrs 1.5 hrs 60 mins
Hard Dry [ISO 9117-1:2009] 60 hrs 24 hrs 6 hrs 4 hrs
Pot Life 26 hrs 12 hrs 2 hrs 60 mins
Overcoated By
23°F 41°F 77°F 95°F
Min Max Min Max Min Max Min Max
Drying and overcoating times quoted are measured at 2 mils dry, at higher film thickness times will be increased.Note
Interthane 990 60 hrs ext 24 hrs ext 6 hrs ext 4 hrs ext
REGULATORY DATA VOC
Note: VOC values are typical and are provided for guidance purposes only. These may be subject to variation depending on factors such as differences in color and normal manufacturing tolerances.
420 g/lt (3.50 lb/US gal) as supplied (EPA Method 24) 341 g/kg of liquid paint as supplied. EU Solvent Emissions Directive (Council Directive 1999/13/EC)
MIL SPEC MIL-PRF-24667B, Type I, II, III & VIII Composition G MIL-PRF-24667B, Type I, V, VII & VIII, Composition L for color marking puposes only
Interthane 990 Polyurethane Finish
Ref:508
Issue Date:8/11/2010
Marine Coatings
Interthane 990 Polyurethane Finish
When used as part of an approved scheme, this material has the following certification:
• Fire Resistance - Surface Spread of Flame (WFR) - (IMO Resolution A653 (16))
• Fire Resistance - MSC61(67) Smoke & Toxicity (WFR)
• NORSOK M-501, Rev 4, system no.1 (NITN)
• Fire Resistance - Marine Equipment Directive compliant
Consult your International Paint representative for details.
CERTIFICATION
Interthane 990 must be applied over a recommended primer system, which will vary depending upon the vessel area. Direct application is acceptable over the following marine anticorrosives:
Intershield 300 Intergard 400 Intershield 803 Interbond 201 Temperate Interbond 501 Intergard 264 (U.S.A.)
A tiecoat of Intergard 263, Intergard 267 or Intergard 269 may be required if Interthane 990 is to be applied over other epoxy primers and may also be used to extend the maximum overcoating interval when Interthane 990 is to be applied over those primers listed above.
Interprime 198 may also be used as a primer for Interthane 990.
Consult your International Paint representative for the system best suited for the surfaces to be protected.
SYSTEMS AND
COMPATIBILITY
Use in accordance with the standard Worldwide Marine Specifications.
All surfaces to be coated should be clean, dry and free from contamination.
High pressure fresh water wash or fresh water wash, as appropriate, and remove all oil or grease, soluble contaminants and other foreign matter in accordance with SSPC-SP1 solvent cleaning.
SURFACE PREPARATIONS
NEWBUILDING/MAJOR REFURBISHMENT
Interthane 990 should always be applied over a recommended primer coating scheme. The primer surface should be dry and free from all contamination, and Interthane 990 must be applied within the overcoating intervals specified (consult the relevant product data sheet). For boottop areas the overcoating intervals for primers are reduced.
Consult International Paint.
Areas of breakdown, damage etc. should be prepared to the specified standard (eg. Sa2½ (ISO 8501-1:2007)) and primed prior to the application of Interthane 990.
REPAIR/OBM
Interthane 990 should always be applied over a recommended primer coating scheme. The primer surface should be dry and free from all contamination, and Interthane 990 must be applied within the overcoating intervals specified (consult the relevant product data sheet). For boottop areas the overcoating intervals for primers are reduced.
Consult International Paint.
Areas of breakdown, damage etc. should be prepared to the specified standard (eg. Sa2½ (ISO 8501-1:2007)) and primed prior to the application of Interthane 990.
Interthane 990 may be applied directly over aged Interthane 990 following thorough fresh water washing and degreasing provided the coating to be overcoated is in an intact and tightly adherent condition. Loose or flaking coatings should be removed back to a firm edge and Interthane 990 or an appropriate primer should be used to repair the area before application of the full coat.
This product may be applied directly over most generic types of paint that have been aged for at least 3 months. It is advisable that a small trial be carried out before applying a full coat.
Consult your International Paint representative for specific recommendations.
NOTE
For use in Marine situations in North America, the following surface preparation standards can be used:
SSPC-SP10 in place of Sa2½ (ISO 8501-1:2007)
Ref:508
Material is supplied in 2 containers as a unit. Always mix a complete unit in the proportions supplied.
(1) Agitate Base (Part A) with a power agitator.
(2) Combine entire contents of Curing Agent (Part B) with Base (Part A) and mix thoroughly with power agitator.
Suitable.
Suitable.
Not recommended. Use International GTA056, GTA713, GTA733 only in exceptional circumstances. DO NOT USE ANY OTHER THINNER. DO NOT thin more than allowed by local environmental legislation
International GTA056/GTA713/GTA733
In the event welding or flame cutting is performed on metal coated with this product, dust and fumes will be emitted which will require the use of appropriate personal protective equipment and adequate local exhaust ventilation. In North America do so in accordance with instruction in ANSI/ASC Z49.1 "Safety in Welding and Cutting."
Recommended Tip Range 13-18 thou (0.33-0.45 mm) Total output fluid pressure at spray tip not less than 2200 psi (155 kg/cm²)
Use suitable proprietary equipment. Thinning may be required.
APPLICATION
Mixing
Airless Spray
Conventional Spray
Brush
Roller
Thinner
Cleaner
Welding
Work Stoppages and Cleanup Do not allow material to remain in hoses, gun or spray equipment. Thoroughly flush all equipment with International GTA056/GTA713/GTA733. Once units of paint have been mixed they should not be resealed and it is advised that after prolonged stoppages work recommences with freshly mixed units.
Clean all equipment immediately after use with International GTA056/GTA713/GTA733. It is good working practice to periodically flush out spray equipment during the course of the working day. Frequency of cleaning will depend upon amount sprayed, temperature and elapsed time, including any delays. Do not exceed pot life limitations.
All surplus materials and empty containers should be disposed of in accordance with appropriate regional regulations/legislation.
All work involving the application and use of this product should be performed in compliance with all relevant national Health, Safety & Environmental standards and regulations.
Prior to use, obtain, consult and follow the Material Safety Data Sheet for this product concerning health and safety information. Read and follow all precautionary notices on the Material Safety Data Sheet and container labels. If you do not fully understand these warnings and instructions or if you can not strictly comply with them, do not use this product. Proper ventilation and protective measures must be provided during application and drying to keep solvent vapor concentrations within safe limits and to protect against toxic or oxygen deficient hazards. Take precautions to avoid skin and eye contact (ie. gloves, goggles, face masks, barrier creams etc.) Actual safety measures are dependant on application methods and work environment.
EMERGENCY CONTACT NUMBERS:
USA/Canada - Medical Advisory Number 1-800-854-6813 Europe - Contact (44) 191 4696111. For advice to Doctors & Hospitals only contact (44) 207 6359191 China – Contact (86) 532 83889090 Shanghai - Contact (86) 21 62679090 R.O.W. - Contact Regional Office
Warning: Contains isocyanate. Wear air-fed hood for spray application.
SAFETY
Ref:508
This product is not recommended for use in permanantly immersed conditions.
Interthane 990 may be used on boottop areas at reduced overcoating intervals over appropriate primers. Consult International Paint.
For brush and roller application, and in some colors, two coats of Interthane 990 may be required to give uniform coverage, especially when applying Interthane 990 over dark undercoats and when using certain lead-free bright finish colors such as yellows and oranges. Best practice is to use a color compatible intermediate or anticorrosive coating under Interthane 990.
Interthane 990 may be applied at substrate temperatures down to 5°F. Before applications are made below 23°F consult your local IP representative for further detail of application procedure.
Low temperature, high relative humidity and condensation occurring during or immediately after application may result in a matt finish and an inferior film. Premature exposure to ponding water will cause color change, especially in dark colors and at low temperatures.
Overcoating information is given for guidance only and is subject to regional variation depending upon local climate and environmental conditions. Consult your local International Paint representative for specific recommendations.
Apply in good weather. Temperature of the surface to be coated must be at least 5°F above the dew point. For optimum application properties bring the material to 70°F-81°F, unless specifically instructed otherwise, prior to mixing and application. Unmixed material (in closed containers) should be maintained in protected storage in accordance with information given in the STORAGE Section of this data sheet. Technical and application data herein is for the purpose of establishing a general guideline of the coating application procedures. Test performance results were obtained in a controlled laboratory environment and International Paint makes no claim that the exhibited published test results, or any other tests, accurately represent results found in all field environments. As application, environmental and design factors can vary significantly, due care should be exercised in the selection, verification of performance and use of the coating.
In the overcoating data section 'ext' = extended overcoating period. Please refer to our Marine Painting Guide - Definitions and Abbreviations available on our website.
LIMITATIONS
UNIT SIZE Unit Size Part A Part B
Vol Pack Vol Pack
Note : US containers are short filled For availability of other unit sizes consult International Paint
20 lt 17.14 lt 20 lt 2.86 lt 5 lt
5 US gal 5 US gal 5 US gal 1 US gal 1 US gal
1 US gal 1 US gal 1 US gal 1 US quart 1 US quart
UNIT SHIPPING WEIGHT Unit Size Unit Weight
20 lt 26.59 Kg
5 US gal 54.7 lb
1 US gal 13.7 lb
Shelf Life Part A - 24 months minimum at 77°F.
Part B - 12 months minimum at 77°F Subject to reinspection thereafter. Store in dry, shaded conditions away from sources of heat and ignition.
STORAGE
Consult International Paint.WORLDWIDE AVAILABILITY
The information in this data sheet is not intended to be exhaustive; any person using the product for any purpose other than that specifically recommended in this data sheet without first obtaining written confirmation from us as to the suitability of the product for the intended purpose does so at their own risk. All advice given or statements made about the product (whether in this data sheet or otherwise) is correct to the best of our knowledge but we have no control over the quality or the condition of the substrate or the many factors affecting the use and application of the product. Therefore, unless we specifically agree in writing to do so, we do not accept any liability at all for the performance of the product or for (subject to the maximum extent permitted by law) any loss or damage arising out of the use of the product. We hereby disclaim any warranties or representations, express or implied, by operation of law or otherwise, including, without limitation, any implied warranty of merchantability or fitness for a particular purpose. All products supplied and technical advice given are subject to our Conditions of Sale. You should request a copy of this document and review it carefully. The information contained in this data sheet is liable to modification from time to time in the light of experience and our policy of continuous development. It is the user's responsibility to check with their local International Paint representative that this data sheet is current prior to using the product.
This Technical Data Sheet is available on our website at www.international-marine.com or www.international-pc.com, and should be the same as this document. Should there be any discrepancies between this document and the version of the Technical Data Sheet that appears on the website, then the version on the website will take precedence.
IMPORTANT NOTE
and product names mentioned in this data sheet are trademarks of or are licensed to AkzoNobel.
© AkzoNobel, 2013 www.international-marine.com
Ref:508
Issue Date:8/11/2010 http://www.international-marine.com
File details come from the government source that posted it. Updated .