This solicitation is seeking a firm fixed price purchase order for drydocking repairs and an ABS Intermediate Survey of the training ship T.S. KENNEDY. The work includes tail shaft examination, blasting and coating of the hull, ultrasonic thickness gauging, tank cleaning and inspections, propeller and stern tube bearing replacement, and crop and renewal of miscellaneous steel structures and foundations. The ship will be available for drydocking on February 26, 2020, with a performance period starting on March 1, 2020 and project completion required by May 1, 2020. A site visit will be held on December 17, 2019. Questions regarding the solicitation must be submitted by December 20, 2019. Interested contractors should request drawings and manuals during the site visit. The soliciting agency is the Department of Transportation Maritime Administration.

View the file

Other files

File Type Posted
6933A220Q000005 - Orig Attachment 1 Quote Pricing Sheet.xlsx XLSX spreadsheet
SHAFTING WRENCHES 1-2.pdf PDF
AUX MACH RM SW SERVICE SYS DIA- 540TV-001-524-20(E).pdf PDF
540TV-001-167-02 (ALL SHEETS).pdf PDF
SHAFTING DETAILS COUPLING C3-100-S43-1-2.pdf PDF
Interspeed 6400NA.pdf PDF
540TV-583-01E Fire & Safety Plan.pdf PDF
Approved Coatings Spreadsheet3.pdf PDF
18027 KENNEDY SHELL CONNECTIONS.PDF PDF
6933A220Q000005 T.S. KENNEDY FY-20 Drydocking Repairs.pdf PDF
540TV-001-835-09 WELDING SEQUENCE.pdf PDF
128-Shaft Alignment Guide_e.pdf PDF
DRW and Ref materials listed in the SOW.xlsx XLSX spreadsheet
SEA CHESTS C3-100 S48-23-1 REV 4.pdf PDF
Hydrotorque Origional Parts Outfitting.pdf PDF
540TV-001-321-01 REV. W ELECTRICAL LOAD ANALYSIS.pdf PDF
Internzational Interline 925.pdf PDF
Hinge DRW Figure 43A.pdf PDF
SHAFTING DETAILS COUPLING C3-100-S43-1-3.pdf PDF
TS Kennedy Tanks Log 5-29-2015 start of tank request.xls XLS spreadsheet
6933A220Q000005 - Attachment 1 Quote Pricing Sheet.xlsx XLSX spreadsheet
RUDDER STOCK CARRIER & BEARINGS C3-100-S22-1-3.pdf PDF
Intergard 264 (2).pdf PDF
Approved Coatings Spreadsheet2.pdf PDF
INTERLAC 665.pdf PDF
540TV-001-801-01 - General Arrangement.pdf PDF
Interfine 5703.pdf PDF
AUX SEA CHESTS PORT SIDE 1-3.pdf PDF
Detail of echo sounder.docx DOCX document
RRF Coatings Guidelines[Apr 2000].pdf PDF
Pages from SVR_Part_4_e-Jan18 2.pdf PDF
ARRGT. OF SHAFTING C3-1--S43-1-1.pdf PDF
156-s11-5-5 All sheets.pdf PDF
Interthane 990 Marine.pdf PDF
KDY CAPACITY PLAN.pdf PDF
TS Kennedy Valve Tracking.xlsx XLSX spreadsheet
172-S48-23-03BC - 48-23-3BC - OVERBOARD DISCHARGE SHELL EXPANSION & LIST OF SEA VALVES.pdf PDF
Docking Plan C3-100 S7-0-1BC.pdf PDF
ds-80.pdf PDF
TANK CAPACITY CURVES C3-100 S29-1-3 BC.pdf PDF
System Requirements.pdf PDF
SHELL EXP. AFT 1-5 C3-100-S11-1-2 .pdf PDF
1208-S33-2 KENNEDY navlab vestibule.pdf PDF
TG Gland seal Reg.pdf PDF
WELDING SEQUENCE C3-100-S29-6-3.pdf PDF
Suggested Sources AB removal.docx DOCX document
SHELL EXP. FWD 1-4 C3-100-S11-1-1.pdf PDF
RUDDER 1-4.pdf PDF
Surface Prep.pdf PDF
156-S11-3-4 FORE PEAK FRAMING.pdf PDF
Show 40 more

Latest 50 of 68 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A <340g/l VOC light colored, abrasion resistant, aluminium pure epoxy coating giving excellent long term anticorrosive protection and low temperature application capability.

PRODUCT DESCRIPTION

A universal primer which can be applied directly to mechanically prepared shop primer or suitably prepared bare steel. Suitable for use with controlled cathodic protection. A tank coating which is approved for the carriage of potable water.

For use at Newbuilding or Maintenance & Repair.

Certified to ANSI/NSF Standard 61.

NSF Certification is for tanks greater than 5,000 gallons

INTENDED USES

ENA310-Bronze, ENA311-Aluminum

63% ±2% (ISO 3233:1998)

6 mils dry (9.5 mils wet)

168 ft²/US gal at 6 mils dft, allow appropriate loss factors

Airless Spray, Brush, Roller

PRODUCT INFORMATION

Volume Solids

Typical Film Thickness

Theoretical Coverage

Method of Application

Finish/Sheen Matt

Part B (Curing Agent) ENA313

Mix Ratio 1.00 volume(s) Part A to 1 volume(s) Part B

Flash Point Part A 106°F; Part B 79°F; Mixed 88°F

Induction Period Not required

Overcoating Data - see limitations Substrate Temperature

Color

Drying Information 23°F 41°F 77°F 95°F

Touch Dry [ISO 9117/3:2010] 6 hrs 4 hrs 3 hrs 60 mins

Hard Dry [ISO 9117-1:2009] 28 hrs 17 hrs 4 hrs 2 hrs

Pot Life 6 hrs 6 hrs 2 hrs 60 mins

Overcoated By

23°F 41°F 77°F 95°F

Min Max Min Max Min Max Min Max

For Intergard 740, Interthane 990 and Interthane 990HS a minimum temperature of 41°F is required to achieve full cure and specified performance.

1For Intershield 300V - Non Immersed Areas, the maximum overcoating times are subject to inspection and evaluation.

Note

Interfine 5703 - - - - 4 hrs 5 days 2 hrs 3 days

Interfine 979 30 hrs 5 days 18 hrs 5 days 6.5 hrs 3 days 4 hrs 3 days

Intergard 267 30 hrs 14 days 18 hrs 14 days 6.5 hrs 14 days 4 hrs 14 days

Intergard 740 30 hrs 7 days 18 hrs 7 days 6.5 hrs 7 days 4 hrs 7 days

Intershield 300V Immersed Areas

30 hrs 14 days 18 hrs 14 days 6.5 hrs 14 days 4 hrs 14 days

Intershield 300V Non Immersed Areas¹

30 hrs¹ 6 mths¹ 18 hrs¹ 6 mths¹ 6.5 hrs¹ 5.5 mths¹ 4 hrs¹ 3 mths¹

Intershield 6GV - - 24 hrs 7 days 24 hrs 7 days 24 hrs 5 days

Interthane 990 30 hrs 3 days 18 hrs 3 days 6.5 hrs 3 days 4 hrs 3 days

Interthane 990HS 30 hrs 3 days 18 hrs 3 days 6.5 hrs 3 days 4 hrs 3 days

REGULATORY DATA VOC

Note: VOC values are typical and are provided for guidance purposes only. These may be subject to variation depending on factors such as differences in color and normal manufacturing tolerances.

326 g/lt (2.72 lb/US gal) as supplied (EPA Method 24)

Intershield 300V Abrasion Resistant Aluminium Pure Epoxy

Ref:2765

Issue Date:2/4/2015

Marine Coatings

Abrasion Resistant Aluminium Pure Epoxy

When used as part of an approved scheme, this product has the following certification:

• Food Contact - Carriage of Grain (NOHA)

• Fire Resistance - Marine Equipment Directive compliant

• Fire Resistance - Surface Spread of Flame (Exova Warringtonfire)

• Fire Resistance - Smoke & Toxicity (Exova Warringtonfire)

• Potable Water - Certification for tanks greater than 5,000 gallons (ANSI Standard 61)

Potable Water Certification issued by external bodies is dependent upon formulation and/or manufacturing site.

Based on this, products supplied in different territories may not be approved to all of the standards listed above.

Consult your International Paint representative for details.

CERTIFICATION

Consult your International Paint representative for the system best suited for the surfaces to be protected.

If overcoating Intershield 300V with antifoulings or single pack finishes, the first coat of material must be applied while the Intershield 300V is soft to thumbprint or slightly tacky.

When using in cargo holds, consult the Intershield 300V Cargo Hold Application Procedures.

For tank coating, consult International Paint for the detailed coating procedures that should be followed.

SYSTEMS AND

COMPATIBILITY

Use in accordance with the standard Worldwide Marine Specifications.

All surfaces to be coated should be clean, dry and free from contamination.

High pressure fresh water wash or fresh water wash, as appropriate, and remove all oil or grease, soluble contaminants and other foreign matter in accordance with SSPC-SP1 solvent cleaning.

SURFACE PREPARATIONS

NEWBUILDING

Where necessary, remove weld spatter and smooth weld seams and sharp edges.

Weld seams and areas of shop primer damage or breakdown should be blast cleaned to Sa2½ (ISO 8501-1:2007) or power tooled to Pt3 (JSRA SPSS:1984).

Intact, approved, shop primers must be clean, dry and free from soluble salts and any other surface contaminants.

Unapproved shop primers will require complete removal by blast cleaning to Sa2½ (ISO 8501-1:2007). In some cases sweep blasting to a defined International Paint standard (eg AS2 or AS3) may be acceptable. Consult your International Paint representative for specific recommendations.

MAJOR REFURBISHMENT

Abrasive blast clean to minimum Sa2 (ISO 8501-1:2007) or International Paint Hydroblasting Standard HB2M. If oxidation has occurred between blasting and application of Intershield 300V, the surface should be reblasted to the specified visual standard.

Surface defects revealed by the blast cleaning process, should be ground, filled, or treated in the appropriate manner.

REPAIR

Consult International Paint.

Consult your International Paint representative for specific recommendations.

When full abrasive blasting is carried out, a sharp angular surface profile of 2-4 mils is recommended.

NOTE

For use in Marine situations in North America, the following surface preparation standards can be used:

SSPC-SP10 in place of Sa2½ (ISO 8501-1:2007) SSPC-SP6 in place of Sa2 (ISO 8501-1:2007) SSPC-SP11 in place of Pt3 (JSRA SPSS:1984)

Ref:2765

Material is supplied in 2 containers as a unit. Always mix a complete unit in the proportions supplied. Once the unit has been mixed it must be used within the working pot life specified.

(1) Agitate Base (Part A) with a power agitator.

(2) Combine entire contents of Curing Agent (Part B) with Base (Part A) and mix thoroughly with power agitator.

Application by brush is recommended for small areas only. Multiple coats may be required to achieve specified film thickness.

Application by roller is recommended for small areas only. Multiple coats may be required to achieve specified film thickness.

Use International GTA220 only in exceptional circumstances. DO NOT thin more than allowed by local environmental legislation.

International GTA822/GTA415

In the event welding or flame cutting is performed on metal coated with this product, dust and fumes will be emitted which will require the use of appropriate personal protective equipment and adequate local exhaust ventilation. In North America do so in accordance with instruction in ANSI/ASC Z49.1 "Safety in Welding and Cutting."

Recommended Tip Range 19-25 thou (0.48-0.64 mm) Total output fluid pressure at spray tip not less than 3000 psi (211 kg/cm²)

- Pump Ratio 40:1 minimum

APPLICATION

Mixing

Airless Spray

Brush

Roller

Thinner

Cleaner

Welding

Work Stoppages and Cleanup Do not allow material to remain in hoses, gun or spray equipment. Thoroughly flush all equipment with International GTA822/GTA415. Once units of paint have been mixed they should not be resealed and it is advised that after prolonged stoppages work recommences with freshly mixed units.

Clean all equipment immediately after use with International GTA822/GTA415. It is good working practice to periodically flush out spray equipment during the course of the working day. Frequency of cleaning will depend upon amount sprayed, temperature and elapsed time, including any delays. Do not exceed pot life limitations.

All surplus materials and empty containers should be disposed of in accordance with appropriate regional regulations/legislation.

All work involving the application and use of this product should be performed in compliance with all relevant national Health, Safety & Environmental standards and regulations.

Prior to use, obtain, consult and follow the Material Safety Data Sheet for this product concerning health and safety information. Read and follow all precautionary notices on the Material Safety Data Sheet and container labels. If you do not fully understand these warnings and instructions or if you can not strictly comply with them, do not use this product. Proper ventilation and protective measures must be provided during application and drying to keep solvent vapor concentrations within safe limits and to protect against toxic or oxygen deficient hazards. Take precautions to avoid skin and eye contact (ie. gloves, goggles, face masks, barrier creams etc.) Actual safety measures are dependant on application methods and work environment.

EMERGENCY CONTACT NUMBERS:

USA/Canada - Medical Advisory Number 1-800-854-6813 Europe - Contact (44) 191 4696111. For advice to Doctors & Hospitals only contact (44) 207 6359191 R.O.W. - Contact Regional Office

SAFETY

Ref:2765

Intershield 300V should be high pressure fresh water washed and/or solvent washed prior to overcoating, where necessary, to ensure removal of any surface contamination that has accumulated.

Suitable for use on tanker decks subject to Classification Society Regulations.

Intershield 300V may be applied at substrate temperatures down to 23°F, however consideration should be given when overcoating at low temperatures as the remainder of the system may require higher temperatures to achieve full cure.

For North America: if overcoating Intershield 300V direct with antifoulings, the first coat of antifouling must be applied while the Intershield 300V is still tacky.

For use in potable water tank linings, as a two coat system with a 10 mils dft, nominal and cure of 30 days minimum at 77°F and 50% relative humidity.

Overcoating information is given for guidance only and is subject to regional variation depending upon local climate and environmental conditions. Consult your local International Paint representative for specific recommendations.

Apply in good weather. Temperature of the surface to be coated must be at least 5°F above the dew point. For optimum application properties bring the material to 70°F-80°F, unless specifically instructed otherwise, prior to mixing and application. Unmixed material (in closed containers) should be maintained in protected storage in accordance with information given in the STORAGE Section of this data sheet. Technical and application data herein is for the purpose of establishing a general guideline of the coating application procedures. Test performance results were obtained in a controlled laboratory environment and International Paint makes no claim that the exhibited published test results, or any other tests, accurately represent results found in all field environments. As application, environmental and design factors can vary significantly, due care should be exercised in the selection, verification of performance and use of the coating.

LIMITATIONS

UNIT SIZE Unit Size Part A Part B

Vol Pack Vol Pack

For availability of other unit sizes consult International Paint

5 US gal 2.5 US gal 2.5 US gal 2.5 US gal 5 US gal

UNIT SHIPPING WEIGHT Unit Size Unit Weight

5 US gal 59 lb

Shelf Life 12 months minimum at 77°F. Subject to re-inspection thereafter. Store in dry, shaded conditions away from sources of heat and ignition.

STORAGE

Consult International Paint.WORLDWIDE AVAILABILITY

The information in this data sheet is not intended to be exhaustive; any person using the product for any purpose other than that specifically recommended in this data sheet without first obtaining written confirmation from us as to the suitability of the product for the intended purpose does so at their own risk. All advice given or statements made about the product (whether in this data sheet or otherwise) is correct to the best of our knowledge but we have no control over the quality or the condition of the substrate or the many factors affecting the use and application of the product. Therefore, unless we specifically agree in writing to do so, we do not accept any liability at all for the performance of the product or for (subject to the maximum extent permitted by law) any loss or damage arising out of the use of the product. We hereby disclaim any warranties or representations, express or implied, by operation of law or otherwise, including, without limitation, any implied warranty of merchantability or fitness for a particular purpose. All products supplied and technical advice given are subject to our Conditions of Sale. You should request a copy of this document and review it carefully. The information contained in this data sheet is liable to modification from time to time in the light of experience and our policy of continuous development. It is the user's responsibility to check with their local representative that this data sheet is current prior to using the product.

This Technical Data Sheet is available on our website at www.international-marine.com or www.international-pc.com, and should be the same as this document. Should there be any discrepancies between this document and the version of the Technical Data Sheet that appears on the website, then the version on the website will take precedence.

IMPORTANT NOTE

All trademarks mentioned in this publication are owned by, or licensed to, the AkzoNobel group of companies.

© AkzoNobel, 2015 www.international-marine.com

Ref:2765

Issue Date:2/4/2015 http://www.international-marine.com

File details come from the government source that posted it. Updated .