570-17-210.OPC.IFC.DWG.20210618Part-5of10.pdf

PDF 8 MB Posted

Attached to
Z2DA--REMODEL EMERGENCY DEPARTMENT FOR OBSERVATION BEDS | 570-17-210
Solicitation number
36C26121R0066
Issued by

View the file

Other files

File Type Posted
36C26121R0066 0005.docx DOCX document
36C26121R0066 0004.docx DOCX document
Site Visit Sign-in Sheet--12.1.2021.pdf PDF
Site Visit Sign-in Sheet--11.10.2021.pdf PDF
36C26121R0066--Responses to Pre-Proposal RFIs (1-17)--Complete--12.6.2021.pdf PDF
Specification 11 73 00-rev01-12.03.2021.pdf PDF
36C26121R0066 0003.docx DOCX document
36C26121R0066--Responses to Pre-Proposal RFIs (1-17).pdf PDF
36C26121R0066 0002.docx DOCX document
36C26121R0066--Responses to Pre-Proposal RFIs (1-10).pdf PDF
ACM Report.pdf PDF
36C26121R0066 0001.docx DOCX document
570-17-210.OPC.IFC.DWG.20210618Part-7of10.pdf PDF
570-17-210.OPC.IFC.DWG.20210618Part-1of10.pdf PDF
570-17-210.OPC.IFC.DWG.20210618Part-8of10.pdf PDF
570-17-210.OPC.IFC.DWG.20210618Part-10of10.pdf PDF
570-17-210.OPC.IFC.DWG.20210618Part-3of10.pdf PDF
570-17-210.OPC.IFC.DWG.20210618Part-6of10.pdf PDF
570-17-210.OPC.IFC.DWG.20210618Part-2of10.pdf PDF
570-17-210.OPC.IFC.DWG.20210618Part-4of10.pdf PDF
570-17-210.OPC.IFC.DWG.20210618Part-9of10.pdf PDF
Factor 6 - Divisional Construction Costs.pdf PDF
REQUEST FOR INFORMATION (RFI) FORM--36C26121R0066.docx DOCX document
Factor 4 - Past Performance (Questionnaire).docx DOCX document
570-17-210.OPC.IFC.Specification.R2.20210618Part-4.pdf PDF
570-17-210.OPC.IFC.Specification.R2.20210618Part-2.pdf PDF
Factor 2 - Key Personnel Qualifications Resumes.xlsx XLSX spreadsheet
570-17-210.OPC.IFC.Specification.R2.20210618Part-3.pdf PDF
VHA_DIRECTIVE_1193_D_2021_08_13--Vaccination_Program.pdf PDF
General Decision Number CA20210018 10.08.2021.pdf PDF
Responsibility - Contractor Certification Regarding Safety and Environmental.pdf PDF
Site_Visit_MAP.pdf PDF
Factor 1 - Prime Contractor Project Experience.xlsx XLSX spreadsheet
570-17-210.OPC.IFC.Specification.R2.20210618Part-1.pdf PDF
36C26121R0066_2.docx DOCX document
Show all 35

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

DN

DN

FD FD

A-200

F7

A-200

C4

A-200

F1

BOPC.1

A

BOPC.2 BOPC.3 4 5 65.A

A.1

B

B.1

C

D

E

BOPC.F

BOPC.G

BOPC.7

CLINICAL

CHARTING RM

B1C29B1C29

LOCKER RM

B1C20AB1C20A

ELEVATOR

B-19B-19

VESTIBULE

106106

SOCIAL WORK

OFFICE

B1C01B1C01

LINEN CART

ALCOVE

ON-CALL RM

B1C18B1C18

TOILET

B1C19B1C19

STAFF

LOUNGE

B1C20B1C20

STAIR

B1C21B1C21

TOILET

B1C08B1C08

TRAUMA RM

SMALL

B1C06B1C06

TRAUMA RM

LARGE

B1C07B1C07

X-RAY

ALCOVE

118118

CORRIDOR

B1C-4B1C-4

ELECTRIC

CLOSET

B1C16B1C16 TELEPHONE

CLOSET

B1C15B1C15

OBSERVATION/

TREATMENT

RM

B1C11B1C11

ENTRANCE

123123

INTERVENTION

(SECLUSION)

ROOM

B1C28B1C28

TRIAGE RM

B1C31B1C31

AOD/

CHECK-IN

B1C30B1C30

MECHANICAL

ROOM

B1C17B1C17

LINEN

CLOSET

B1C41B1C41

LINEN

CLOSET

B1C42B1C42

STAIR NO.4

B1C43B1C43

ELEVATOR

EQUIP RM

B1C40B1C40

LINEN

CLOSET

B1C39B1C39

CHIEF OF ER

B1C35B1C35

HEAD NURSE

B1C37B1C37

EMS CLOSET

B1C36B1C36

CORRIDOR

B1C-1B1C-1

WAITING

B1C-1B1C-1

MALE RR

B1C33B1C33

FEMALE RR

B1C32B1C32

ELEVATOR

S-5S-5

PATIENT

COMFORT

ROOM

BC127BC127

CHARTING

ALCOVE

POLICE

DISPATCH

B1C02B1C02

C O

R R

ID

O

R B

1C -5

B 1C

-5

OBSERVATION/

TREATMENT

RM

B1C10B1C10

ELEV. EQUIP/

SUMP

178178

OBSERVATION/

TREATMENT

RM

B1C12B1C12

OBSERVATION/

TREATMENT

RM

B1C13B1C13

OBSERVATION/

TREATMENT

RM

B1C09B1C09

OBSERVATION/

TREATMENT

RM

B1C14B1C14

CORRIDOR

B1C-2B1C-2

PROCEDURE

RM

B1C05B1C05

WHEELCH.

SCALE

EXAM AREA

B1C04B1C04

EXAM AREA

B1C03B1C03

VESTIBULE

NEW

OBSERVATION

ROOM

B1C23B1C23

NEW

OBSERVATION

ROOM

B1C21B1C21

NEW

OBSERVATION

ROOM

BC24BC24

SOILED

UTILITY

B1C53B1C53

HAC

BC50BC50

CORRIDOR

B1C-9B1C-9

NEW NURSES

STATION

B1C34FB1C34F

NEW

OBSERVATION

ROOM

B1C34KB1C34K

PAT TLT

B1C34JB1C34J

AREAWAY

103103

CLEAN

UTILITY

B1C52B1C52

STF TLT

BC51BC51

PAT TLT

B1C25AB1C25A

PAT SHWR

B1C25BB1C25B

CLEAN

UTILITY

BC26BC26

NEW

OBSERVATION

ROOM

B1C34AB1C34A

NEW

OBSERVATION

ROOM

B1C34CB1C34C

NEW

OBSERVATION

ROOM

B1C34EB1C34E

NEW

OBSERVATION

ROOM

B1C34GB1C34G

ELEVATOR

S-6S-6

A-401

B7

A-401

C7 A-401

D7

A-401

F7

A-402

C7

A-402

E7

A-402

F7

A-100B

F4

CORRIDOR

B1C-1AB1C-1A

AREA WAY, BELOW GRADE OPENING

CONSTRUCTION

FENCING

F7

A-350

F7

A-350

F5

A-350

F5

A-350

NEW NURSES

STATION

B1C34BB1C34B

NEW

STORAGE

B1C34DB1C34D

NEW

STORAGE

B1C34HB1C34H

WALL TYPE LEGEND

TEMPORARY WALL

DEMOLISHED WALL, FIXTURE OR FURNISHING

EXISTING WALL, FIXTURE OR FURNISHING

NEW WALL

AREA NOT IN SCOPE

CONTRACT LIMIT

DEMOLISHED FURNITURE OR EQUIPMENT, SALVAGE TO OWNER

EQUIPMENT LEGEND

V V ITEM - VA SUPPLIED & INSTALLED

V C ITEM - VA SUPPLIED &

CONTRACTOR INSTALLED

C C ITEM - CONTRACTOR SUPPLIED &

INSTALLED

FURNITURE, FIXTURE, & EQUIPMENT

INDICATOR

A1000

1. REMOVE ALL ARCHITECTURAL RENOVATION WORK

ASSOCIATED WITH THE INTERIOR EMERGENCY

DEPARTMENT BED OBSERVATION AREA, THIS

INCLUDES DEMOLITION WORK AND ALL

CONSTRUCTION WORK OUTLINED WITHIN THE "AREA

OF WORK". WORK SHOWN ON A-200, A-350, & A-351

REMAIN.

2. REMOVE ERV (ENERGY RECOVERY VENTILATOR)

FROM AHU (AIR HANDLER UNIT) SELECTION.

3. REMOVE SIGNAGE FROM ED BED OBSERVATION

SCOPE AND TRAILER COMPLETELY. IF DEDUCT ALT.1

IS EXERCISED DEDUCT ALT#3 WOULD COVER THE

REMOVAL OF SIGNAGE FROM THE TRAILER ONLY.

DEDUCTIVE ALTERNATES

NOTE: DEDUCTIVE ALTERNATES ARE NOT

CASCADING. THE OWNER WILL EXERCISE DEDUCTS

AS NEEDED. EACH DEDUCT SHALL BE PRICED UNDER

SEPARATE CLINs (CONTRACT LINE ITEM NUMBER) SO

DETERMINATIONS CAN BE MADE AND PRIORITIES

ESTABLISHED BASED ON BIDS RECEIVED.

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Mechanical, Electrical and Plumbing:

KEY PLAN

A B

D C

B

IM

/5

-1 -2

E x p a n d E

D B e d s

/5

-1

-2

.O

P C

.A R

C H

.r v t

/1

/2

:3

:4

P

M

A-100

ARCHITECTURAL FLOOR PLAN - LEVEL B -

OVERALL

TRIPLE C - THE A-E GROUP

4401 Atlantic Avenue, Suite 200

Long Beach, CA 90807

562.452.7175

MAT PERKINS

REMODEL ED BEDS FOR

OBSERVATION BEDS

2615 E. CLINTON AVENUE, FRESNO, CA 93703

570-17-210

OPC

6/18/2021 M. PERKINS E. DANIELS

ISSUED FOR

CONSTRUCTION

1/8" = 1'-0" F2

ARCHITECTURAL PROPOSED PLAN - LEVEL B - OVERALL

GENERAL SHEET NOTES

1. ACCESS TO EXISTING FIRE EXIT SHALL REMAIN OPERATIONAL DURING ALL

PHASES OF CONSTRUCTION. ENSURE ADEQUATE EGRESS CLEARANCES ARE

MAINTAINED AND NOT IMPEDED DURING PHASED CONSTRUCTION.

2. SEE GENERAL SHEETS FOR VA PROJECT NOTES, INFECTION CONTROL AND LIFE

SAFETY / CODE DATA FOR ADDITIONAL INTERIM LIFE SAFETY MEASURES AND

INFORMATION.

3. SEE A-701 FOR INTERIOR WALL TYPES.

4. SEE 'IN' SERIES DRAWINGS FOR INTERIOR DESIGN AND FINISHES.

5. SEE 'AW' SERIES DRAWINGS FOR ARCHITECTURAL SIGNAGE.

6. SEE 'Q-' SERIES DRAWINGS FOR HOSPITAL EQUIPMENT AND FURNISHINGS.

7. NO DRILLING OR JACK HAMMERING ACTIVITIES ALLOWED DURING BUSINESS

HOURS.

KEYNOTES

1 REFER TO SHEET A-100B-1 FOR ARCHITECTURAL DIMENSIONS

2 COMPLETE 1 HOUR FIRE SMOKE BARRIER TO DECK.

3 COMPLETE 1 HOUR FIRE BARRIER TO DECK.

4 EXISTING LADDER ACCESS TO GRADE ABOVE TO REMAIN

PARTITION RATING GRAPHICS:

4 HR FIRE BARRIER

3 HR FIRE BARRIER

2 HR FIRE & SMOKE BARRIER

2 HR FIRE BARRIER

2 HR FIRE BARRIER/SHAFT

1 HR FIRE & SMOKE BARRIER

1 HR FIRE BARRIER

1 HR FIRE BARRIER/SHAFT

SMOKE PARTITION (NON RATED)

NON RATED

PARTITION RATING GRAPHIC DESIGNATION: PRIORITY

1 HIGHEST

5 LOWEST

PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH

FIRE AND SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH

HATCH PATTERNS.

Revisions: Date:

A

4 5 65.A

A.1

B

B.1

C

D

E

INTERVENTION

(SECLUSION)

ROOM

B1C28

119 SF

LINEN

CLOSET

B1C41

18 SF

LINEN

CLOSET

B1C42

19 SF

LINEN

CLOSET

B1C39

11 SF

CHIEF

OF ER

B1C35

127 SF

EMS

CLOSET

B1C36

10 SF

CORRIDOR

B1C-1

328 SF

ELEVATOR

S-5

82 SF

CORRIDOR

B1C-2B1C-2

CORRIDOR

B1C-4B1C-4

INTERVENTION

(SECLUSION)

ROOM

B1C28B1C28

NEW

OBSERVATION

ROOM

B1C23

83 SF

CLEAN

UTILITY

B1C52

66 SF

LINEN

CLOSET

B1C41B1C41

LINEN

CLOSET

B1C42B1C42

STAIR

NO.4

B1C43B1C43

ELEVATOR

EQUIP

RM

B1C40B1C40

LINEN

CLOSET

B1C39B1C39

CHIEF

OF ER

B1C35B1C35

HEAD

NURSE

B1C37B1C37

EMS

CLOSET

B1C36B1C36

WAITING

B1C-1B1C-1

MALE

RR

B1C33B1C33

FEMALE

RR

B1C32B1C32

NEW

NURSES

STATION

B1C34F

67 SF

NEW

OBSERVATION

ROOM

B1C34A

70 SF

ELEVATOR

S-5S-5

ELEVATOR

S-6S-6

HALL

B1C-6A

255 SF

NEW

OBSERVATION

ROOM

B1C21

84 SF

PATIENT

COMFORT

ROOM

BC127BC127

NEW

OBSERVATION

ROOM

B1C34C

78 SF

OBSERVATION/

TREATMENT

RM

B1C14B1C14

SOILED

UTILITY

B1C53

62 SF

CORRIDOR

B1C-2B1C-2

HAC

BC50

51 SF

CORRIDOR

B1C-9B1C-9

CORRIDOR

B1C-7B1C-7

NURSE

STATION

B1C29AB1C29A

CRASH

CART

ALCOVE

A6

A6

A5

A

EXIST

EXIST

EXIST

E X

IS

T

EXIST

EXIST

EXIST

EXIST

EXIST

E X

IS

T

E X

IS

T

E X

IS

T

E X

IS

T

E X

IS

T

EXIST

EXIST

B1C-4

B C

B 1C

B 1C

A-402

C7

A-401

B7

A-402

B6

CR

CONTROLLED EGRESS

CR

CR

A-401

C7

A-401

D7

NEW

OBSERVATION

ROOM

B1C34E

78 SF

NEW

OBSERVATION

ROOM

B1C34G

93 SF

NEW

OBSERVATION

ROOM

B1C34K

105 SF

NEW

STORAGE

B1C34H

13 SF

NEW

STORAGE

B1C34D

14 SF

NEW

NURSES

STATION

B1C34B

36 SF

PAT TLT

B1C34J

54 SF

STF TLT

BC51

53 SF

PAT TLT

B1C25A

67 SF

NEW

OBSERVATION

ROOM

BC24

93 SF

CORRIDOR

B1C-6

246 SF

PAT

SHWR

B1C25B

16 SF

HOLD

8'-0 3/8"

CR

HOLD

8'-0"

H O

LD

6' -0

CLEAN

UTILITY

BC26

70 SF

A-401

F7

A-402

E7

A-402

F7

BC50

B1C-6

B1C34J

BC26

B 1C

-4 A

CR

CR

CORRIDOR

B1C-4B1C-4 B1C-4

B 1C

B 1C

B1C25A

2 2 2

FE

EQUIPMENT LEGEND

V V ITEM - VA SUPPLIED & INSTALLED

V C ITEM - VA SUPPLIED &

CONTRACTOR INSTALLED

C C ITEM - CONTRACTOR SUPPLIED &

INSTALLED

FURNITURE, FIXTURE, & EQUIPMENT

INDICATOR

A1000

WALL TYPE LEGEND

TEMPORARY WALL

DEMOLISHED WALL, FIXTURE OR FURNISHING

EXISTING WALL, FIXTURE OR FURNISHING

NEW WALL

AREA NOT IN SCOPE

CONTRACT LIMIT

DEMOLISHED FURNITURE OR EQUIPMENT, SALVAGE TO OWNER

1. REMOVE ALL ARCHITECTURAL RENOVATION WORK

ASSOCIATED WITH THE INTERIOR EMERGENCY

DEPARTMENT BED OBSERVATION AREA, THIS

INCLUDES DEMOLITION WORK AND ALL

CONSTRUCTION WORK OUTLINED WITHIN THE "AREA

OF WORK". WORK SHOWN ON A-200, A-350, & A-351

REMAIN.

2. REMOVE ERV (ENERGY RECOVERY VENTILATOR)

FROM AHU (AIR HANDLER UNIT) SELECTION.

3. REMOVE SIGNAGE FROM ED BED OBSERVATION

SCOPE AND TRAILER COMPLETELY. IF DEDUCT ALT.1

IS EXERCISED DEDUCT ALT#3 WOULD COVER THE

REMOVAL OF SIGNAGE FROM THE TRAILER ONLY.

DEDUCTIVE ALTERNATES

NOTE: DEDUCTIVE ALTERNATES ARE NOT

CASCADING. THE OWNER WILL EXERCISE DEDUCTS

AS NEEDED. EACH DEDUCT SHALL BE PRICED UNDER

SEPARATE CLINs (CONTRACT LINE ITEM NUMBER) SO

DETERMINATIONS CAN BE MADE AND PRIORITIES

ESTABLISHED BASED ON BIDS RECEIVED.

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Mechanical, Electrical and Plumbing:

KEY PLAN

B

B

IM

/5

-1 -2

E x p a n d E

D B e d s

/5

-1

-2

.O

P C

.A R

C H

.r v t

/1

/2

:3

:4

P

M

A-100B

ARCHITECTURAL FLOOR PLAN - LEVEL B -

AREA B - DEDUCT ALT NO.1

TRIPLE C - THE A-E GROUP

4401 Atlantic Avenue, Suite 200

Long Beach, CA 90807

562.452.7175

MAT PERKINS

REMODEL ED BEDS FOR

OBSERVATION BEDS

2615 E. CLINTON AVENUE, FRESNO, CA 93703

570-17-210

OPC

6/18/2021 M. PERKINS E. DANIELS

ISSUED FOR

CONSTRUCTION

1/4" = 1'-0" F4

ARCHITECTURAL PROPOSED PLAN - LEVEL B - AREA B - DEDUCT ALT NO. 1

GENERAL SHEET NOTES

1. ACCESS TO EXISTING FIRE EXIT SHALL REMAIN OPERATIONAL DURING ALL

PHASES OF CONSTRUCTION. ENSURE ADEQUATE EGRESS CLEARANCES ARE

MAINTAINED AND NOT IMPEDED DURING PHASED CONSTRUCTION.

2. SEE GENERAL SHEETS FOR VA PROJECT NOTES, INFECTION CONTROL AND LIFE

SAFETY / CODE DATA FOR ADDITIONAL INTERIM LIFE SAFETY MEASURES AND

INFORMATION.

3. SEE A-701 FOR INTERIOR WALL TYPES.

4. SEE 'IN' SERIES DRAWINGS FOR INTERIOR DESIGN AND FINISHES.

5. SEE 'AW' SERIES DRAWINGS FOR ARCHITECTURAL SIGNAGE.

6. SEE 'Q-' SERIES DRAWINGS FOR HOSPITAL EQUIPMENT AND FURNISHINGS.

7. NO DRILLING OR JACK HAMMERING ACTIVITIES ALLOWED DURING BUSINESS

HOURS.

1 REFER TO SHEET A-100B-1 FOR ARCHITECTURAL DIMENSIONS

2 NEW CEILING MOUNTED TRACK

3 REMOVAL OF WORK IN THIS AREA IS DEDUCTIVE ALTERNATE NO. 1

4 MUST MAINTAIN EGRESS PATH TO CT SCAN AREA DURING

CONSTRUCTION

5 CONTRACTOR TO PROVIDE A SCHEDULE AND PHASING FOR AFTER

WORK HOURS TO MAINTAIN CORRIDOR ACCESS

PARTITION RATING GRAPHICS:

4 HR FIRE BARRIER

3 HR FIRE BARRIER

2 HR FIRE & SMOKE BARRIER

2 HR FIRE BARRIER

2 HR FIRE BARRIER/SHAFT

1 HR FIRE & SMOKE BARRIER

1 HR FIRE BARRIER

1 HR FIRE BARRIER/SHAFT

SMOKE PARTITION (NON RATED)

NON RATED

PARTITION RATING GRAPHIC DESIGNATION: PRIORITY

1 HIGHEST

5 LOWEST

PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH

FIRE AND SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH

HATCH PATTERNS.

KEYNOTES

4 5 65.A

A.1

B

B.1

C

D

E

LINEN

CLOSET

B1C41

18 SF

LINEN

CLOSET

B1C42

19 SF

LINEN

CLOSET

B1C39

11 SF

CHIEF

OF ER

B1C35

127 SF

EMS

CLOSET

B1C36

10 SF

CORRIDOR

B1C-1B1C-1

ELEVATOR

S-5

82 SF

CORRIDOR

B1C-2B1C-2

CORRIDOR

B1C-4B1C-4

INTERVENTION

(SECLUSION)

ROOM

B1C28B1C28

NEW

OBSERVATION

ROOM

B1C23

TRET4

ACTUAL: 83 SF

PROG: 140 SF

CLEAN

UTILITY

B1C52

LCCL3

ACTUAL: 66 SF

PROG: 60 SF

LINEN

CLOSET

B1C41B1C41

LINEN

CLOSET

B1C42B1C42

STAIR

NO.4

B1C43B1C43

ELEVATOR

EQUIP

RM

B1C40B1C40

LINEN

CLOSET

B1C39B1C39

CHIEF

OF ER

B1C35B1C35

HEAD

NURSE

B1C37B1C37

EMS

CLOSET

B1C36B1C36

WAITING

B1C-1B1C-1

MALE

RR

B1C33B1C33

FEMALE

RR

B1C32B1C32

NEW

NURSES

STATION

B1C34F

NSTA4

ACTUAL: 67 SF

PROG: 80 SF

NEW

OBSERVATION

ROOM

B1C34A

TRET4

ACTUAL: 70 SF

PROG: 140 SF

ELEVATOR

S-5S-5

ELEVATOR

S-6S-6

HALL

B1C-6A

ACTUAL: 255 SF

NEW

OBSERVATION

ROOM

B1C21

TRET4

ACTUAL: 84 SF

PROG: 140 SF

PATIENT

COMFORT

ROOM

BC127BC127

NEW

OBSERVATION

ROOM

B1C34C

TRET4

ACTUAL: 78 SF

PROG: 140 SF

OBSERVATION/

TREATMENT

RM

B1C14B1C14

SOILED

UTILITY

B1C53

USCL1

ACTUAL: 62 SF

PROG: 80 SF

CORRIDOR

B1C-2B1C-2

HAC

BC50

JANC1

ACTUAL: 51 SF

PROG: 60 SF

CORRIDOR

B1C-9B1C-9

CORRIDOR

B1C-7B1C-7

NURSE

STATION

B1C29AB1C29A

CRASH

CART

ALCOVE

A6A6

A

EXIST

EXIST

EXIST

E X

IS

T

EXIST

EXIST

EXIST

EXIST

EXIST

E X

IS

T

E X

IS

T

E X

IS

T

E X

IS

T

E X

IS

T

EXIST

EXIST

B C

B 1C

B 1C

M

IN

. C

LE

A R

6' -0

6'

-3

/4

6' -4

/8

3'

-4

1' -3

/4

3/

8" 7'

-8

2"

'-4

/8

CR

CONTROLLED EGRESS

CR

CR

4'-3" 5'-4"

NEW

OBSERVATION

ROOM

B1C34E

TRET4

ACTUAL: 78 SF

PROG: 140 SF

NEW

OBSERVATION

ROOM

B1C34G

TRET4

ACTUAL: 93 SF

PROG: 140 SF

NEW

OBSERVATION

ROOM

B1C34K

TRET4

ACTUAL: 105 SF

PROG: 140 SF

NEW

STORAGE

B1C34H

SRE01

ACTUAL: 13 SF

PROG: 80 SF

NEW

STORAGE

B1C34D

SRE01

ACTUAL: 14 SF

PROG: 80 SF

NEW

NURSES

STATION

B1C34B

NSTA4

ACTUAL: 36 SF

PROG: 80 SF

PAT TLT

B1C34J

TPG01

ACTUAL: 54 SF

PROG: 60 SF

STF TLT

BC51

TNPG1

ACTUAL: 53 SF

PROG: 60 SF

PAT TLT

B1C25A

TPG01

ACTUAL: 67 SF

PROG: 60 SF

NEW

OBSERVATION

ROOM

BC24

TRET4

ACTUAL: 93 SF

PROG: 140 SF

CORRIDOR

B1C-6

ACTUAL: 246 SF

PAT

SHWR

B1C25B

SHPU1

ACTUAL: 16 SF

PROG: 70 SF

8'-0 3/8"

CR

8'-0"

6' -0

7"

CLEAN

UTILITY

BC26

70 SF

BC50

B1C-6

B1C34J

BC26

B 1C

-4 A

CR

CR

1' -3

CORRIDOR

B1C-4B1C-4 B1C-4

B 1C

B 1C

B1C25A

A5 A6 A3

A5

A4

A

A4A

A

A8

E

A6

A4 A

A6

A

A

A4

A5

A6

A6

A

E

A6

2"

1'-7 1/8" 8'-0 3/8"

3' -9

/4

3'

-2

1' -3

3'

-4

/2

'-1

/8

3'

-3

/4

1' -3

'-0

/8

3'-0 7/8"

3'-1 1/4"

M

IN

. C

LE

A R

8' -0

4'

-0

/4

5' -4

/2

4'

-1

/8

7' -8

/4

1'-8"

6'-2" 9'-7 1/2" 8'-11 1/4" 9'-10 3/8" 8 7/8" 5'-7 5/8"

A

5' -1

/8

9'

-4

/8

5' -1

1/

4"

2' -4

/4

11'-5" 11'-10 5/8" 9'-8 5/8" 1'-8 5/8"

3'-3" 6'-4" 4'-11 3/4" 6'-4" 4'-5 1/8" 3'-4" 2'-2 1/8"

3 1/4" 4'-4"

1' -3

/8

4'

-4

4"

2'-0"

7'-6 3/4"

1/

4"

3' -1

0" 1'

-4

4' -8

/8

8'

-9

/4

A4

A4

A4

A

E

A

A

1'-6"

3"

8 7/8"

MIN. CLR.

8'-0" 9'-7 1/8"

L6

2'-0"

3' -4

/8

1' -5

/8

1'

-9

2' -9

/4

1' -6

M

IN

B5

A-701

SIM

B5

A-701

SIM

B5

A-701

SIM

E

N

7'-7 1/2"

8'-0"

7'-10 1/2"

7'-7 1/2"

8'-4 3/8"

3'-0 5/8"

8'-0"

4'-6 3/8"

3' -4

3'

-7

/8

FE

WALL TYPE LEGEND

TEMPORARY WALL

DEMOLISHED WALL, FIXTURE OR FURNISHING

EXISTING WALL, FIXTURE OR FURNISHING

NEW WALL

AREA NOT IN SCOPE

CONTRACT LIMIT

DEMOLISHED FURNITURE OR EQUIPMENT, SALVAGE TO OWNER

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Mechanical, Electrical and Plumbing:

KEY PLAN

B

B

IM

/5

-1 -2

E x p a n d E

D B e d s

/5

-1

-2

.O

P C

.A R

C H

.r v t

/1

/2

:3

:5

P

M

A-100B-1

ARCHITECTURAL DIMENSION PLAN - LEVEL B -

AREA B

TRIPLE C - THE A-E GROUP

4401 Atlantic Avenue, Suite 200

Long Beach, CA 90807

562.452.7175

MAT PERKINS

REMODEL ED BEDS FOR

OBSERVATION BEDS

2615 E. CLINTON AVENUE, FRESNO, CA 93703

570-17-210

OPC

6/18/2021 M. PERKINS K.

MCDERMOTT

ISSUED FOR

CONSTRUCTION

1/4" = 1'-0" F4

ARCHITECTURAL DIMENSION PLAN - LEVEL B - AREA B

GENERAL SHEET NOTES

1. ACCESS TO EXISTING FIRE EXIT SHALL REMAIN OPERATIONAL DURING ALL

PHASES OF CONSTRUCTION. ENSURE ADEQUATE EGRESS CLEARANCES ARE

MAINTAINED AND NOT IMPEDED DURING PHASED CONSTRUCTION.

2. SEE GENERAL SHEETS FOR VA PROJECT NOTES, INFECTION CONTROL AND LIFE

SAFETY / CODE DATA FOR ADDITIONAL INTERIM LIFE SAFETY MEASURES AND

INFORMATION.

3. SEE A-701 FOR INTERIOR WALL TYPES.

4. SEE 'IN' SERIES DRAWINGS FOR INTERIOR DESIGN AND FINISHES.

5. SEE 'AW' SERIES DRAWINGS FOR ARCHITECTURAL SIGNAGE.

6. SEE 'Q-' SERIES DRAWINGS FOR HOSPITAL EQUIPMENT AND FURNISHINGS.

7. NO DRILLING OR JACK HAMMERING ACTIVITIES ALLOWED DURING BUSINESS

HOURS.

1 NOT USED

PARTITION RATING GRAPHICS:

4 HR FIRE BARRIER

3 HR FIRE BARRIER

2 HR FIRE & SMOKE BARRIER

2 HR FIRE BARRIER

2 HR FIRE BARRIER/SHAFT

1 HR FIRE & SMOKE BARRIER

1 HR FIRE BARRIER

1 HR FIRE BARRIER/SHAFT

SMOKE PARTITION (NON RATED)

NON RATED

PARTITION RATING GRAPHIC DESIGNATION: PRIORITY

1 HIGHEST

5 LOWEST

PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH

FIRE AND SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH

HATCH PATTERNS.

BOPC.2 BOPC.3 4 5 65.A

A.1

B

B.1

C

D

E

CRASH

CART

ALCOVE

9 SF

CLINICAL

CHARTING

RM

B1C29B1C29

VESTIBLUE

ON-CALL

RM

B1C18B1C18

STAFF

LOUNGE

B1C20B1C20

STAIR

B1C21B1C21

TOILET

B1C08B1C08

TRAUMA

RM

SMALL

B1C06B1C06

TRAUMA

RM

LARGE

B1C07B1C07

X-RAY

ALCOVE

B1C07AB1C07A

CORRIDOR

B1C-4B1C-4

ELECTRIC

CLOSET

B1C16B1C16

TELEPHONE

CLOSET

B1C15B1C15

OBSERVATION/

TREATMENT

RM

B1C11B1C11

ENTRANCE

TRIAGE

RM

B1C28B1C28

TRIAGE

RM

B1C31B1C31

AOD/

CHECK-IN

B1C30B1C30

LINEN

CLOSET

B1C41B1C41

LINEN

CLOSET

B1C42B1C42

STAIR

NO.4

B1C43B1C43

ELEVATOR

EQUIP

RM

B1C40B1C40

LINEN

CLOSET

B1C50B1C50

POLICE

CHIEF

OFFICE

B1C35B1C35

PUBLIC

AFFAIRS

B1C37B1C37

EMS

CLOSET

B1C36B1C36

CORRIDOR

B1C-1B1C-1

WAITING

B1C-1B1C-1

CLOSET

B1C34DB1C34D

MALE

RR

B1C33B1C33

FEMALE

RR

B1C32B1C32

ELEVATOR

S-5S-5

ELEVATOR

S-6S-6OBS

BEDS

ROOM

B1C-6AB1C-6A

CORRIDOR

B1C-6B1C-6

PATIENT

COMFORT

ROOM

B1C27B1C27

HEAD

NURSE

B1C53B1C53

CLOSET

SPD

B1C51B1C51

POLICE

DISPATCH

B1C02B1C02

CORRIDOR

B1C-5B1C-5

OBSERVATION/

TREATMENT

RM

B1C10B1C10

OBSERVATION/

TREATMENT

RM

B1C12B1C12

OBSERVATION/

TREATMENT

RM

B1C13B1C13

OBSERVATION/

TREATMENT

RM

B1C09B1C09

OBSERVATION/

TREATMENT

RM

B1C14B1C14

TOILET

B1C24B1C24

OBSERVATION/

TREATMENT

RM

B1C23B1C23

CORRIDOR

B1C-2B1C-2

PROCEDURE

RM

B1C05B1C05

WHEELCH.

SCALE

189189

NURSE

B1C34AB1C34A

NURSE

STATION

B1C29AB1C29A

CORRIDOR

B1C-9B1C-9

CORRIDOR

B1C-7B1C-7

CORRIDOR

B1C-8B1C-8

OBSERVATION/

TREATMENT

RM

B1C26B1C26

EXIST

EXIST

EXIST

E X

IS

T

EXIST

EXIST

EXIST

EXIST

EXIST

E X

IS

T

E X

IS

T

E X

IS

T

E X

IS

T

E X

IS

T

EXIST

EXIST

EXIST

D

D4

CR

CONTROLLED EGRESS

HOLD

8'-0 3/8"

CR

SOILED

UTILITY

RM

B1C55B1C55

TOILET

B1C54B1C54

CHIEF

OF ER

B1C52B1C52

OBSERVATION/

TREATMENT

RM

B1C22B1C22

OBSERVATION/

TREATMENT

RM

B1C25B1C25

SMALL

TOILET

B1C34CB1C34C

2 2

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Mechanical, Electrical and Plumbing:

KEY PLAN

B

B

IM

/5

-1 -2

E x p a n d E

D B e d s

/5

-1

-2

.O

P C

.A R

C H

.r v t

/1

/2

:3

:0

P

M

A-100B-3

ARCHITECTURAL FLOOR PLAN - LEVEL B -

AREA B, DEDUCT ALT. NO. 1

TRIPLE C - THE A-E GROUP

4401 Atlantic Avenue, Suite 200

Long Beach, CA 90807

562.452.7175

MAT PERKINS

REMODEL ED BEDS FOR

OBSERVATION BEDS

2615 E. CLINTON AVENUE, FRESNO, CA 93703

570-17-210

OPC

6/18/2021 MRP ETD

ISSUED FOR

CONSTRUCTION

1/4" = 1'-0" F1

ARCHITECTURAL PROPOSED PLAN - LEVEL B - AREA B, DEDUCT ALT NO.1

GENERAL SHEET NOTES

1. ACCESS TO EXISTING FIRE EXIT SHALL REMAIN OPERATIONAL DURING ALL

PHASES OF CONSTRUCTION. ENSURE ADEQUATE EGRESS CLEARANCES ARE

MAINTAINED AND NOT IMPEDED DURING PHASED CONSTRUCTION.

2. SEE GENERAL SHEETS FOR VA PROJECT NOTES, INFECTION CONTROL AND LIFE

SAFETY / CODE DATA FOR ADDITIONAL INTERIM LIFE SAFETY MEASURES AND

INFORMATION.

3. SEE A-701 FOR INTERIOR WALL TYPES.

4. SEE 'IN' SERIES DRAWINGS FOR INTERIOR DESIGN AND FINISHES.

5. SEE 'AW' SERIES DRAWINGS FOR ARCHITECTURAL SIGNAGE.

6. SEE 'Q-' SERIES DRAWINGS FOR HOSPITAL EQUIPMENT AND FURNISHINGS.

7. NO DRILLING OR JACK HAMMERING ACTIVITIES ALLOWED DURING BUSINESS

HOURS.

PARTITION RATING GRAPHICS:

4 HR FIRE BARRIER

3 HR FIRE BARRIER

2 HR FIRE & SMOKE BARRIER

2 HR FIRE BARRIER

2 HR FIRE BARRIER/SHAFT

1 HR FIRE & SMOKE BARRIER

1 HR FIRE BARRIER

1 HR FIRE BARRIER/SHAFT

SMOKE PARTITION (NON RATED)

NON RATED

PARTITION RATING GRAPHIC DESIGNATION: PRIORITY

1 HIGHEST

5 LOWEST

PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH

FIRE AND SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH

HATCH PATTERNS.

KEYNOTES

1 DEDUCTIVE ALTERNATE NO. 1, THIS AREA IS EXISTING TO REMAIN.

OMIT DEMOLITION AND SCOPE OF WORK OUTLINED WITHIN 'AREA

OF WORK'

S

M

RCP SYMBOL LEGEND

RECESSED OR SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE

SMOKE DETECTOR

SPEAKER

HVAC SUPPLY DIFFUSER

HVAC RETURN DIFFUSER

EXIT LIGHT

HEAT DETECTOR

HVAC EXHAUST DIFFUSER

RECESSED OR SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE

ACOUSTICAL TILE CEILING (24X24)

AT-1

ACOUSTICAL TILE CEILING (24X48)

AT-2

GYPSUM CEILING - PAINTED

CEILING MOUNTED PATIENT LIFT (VA (VV) PROVIDED AND

INSTALLED)

CEILING MOUNTED IV TRACK

SKYFACTORY CEILING PANELS AT-3

ACCESS PANEL

LED RECESSED STRIP LIGHTING

RECESSED DOWN LIGHT FIXTURE - INSTALL CENTERED IN

ACOUSTICAL CEILING TILE UNO

(P-1 UNO)

SPRINKLER

BOPC.1

A

BOPC.2 BOPC.3 4 5 65.A

A.1

B

B.1

C

D

E

BOPC.F

BOPC.G

BOPC.7 BOPC.8

CLINICAL

CHARTING RM

B1C29B1C29

LOCKER RM

B1C20AB1C20A

AREAWAY

103103

ELEVATOR

B-19B-19

VESTIBULE

106106

SOCIAL WORK

OFFICE

B1C01B1C01

LINEN CART

ALCOVE

TRANSFORMER

RM

B1C17AB1C17A

ON-CALL RM

B1C18B1C18

TOILET

B1C19B1C19

STAFF

LOUNGE

B1C20B1C20

STAIR

B1C21B1C21

TOILET

B1C08B1C08

TRAUMA RM

SMALL

B1C06B1C06

TRAUMA RM

LARGE

B1C07B1C07

X-RAY

ALCOVE

118118

CORRIDOR

B1C-4B1C-4

ELECTRIC

CLOSET

B1C16B1C16

TELEPHONE

CLOSET

B1C15B1C15

OBSERVATION/

TREATMENT

RM

B1C11B1C11

ENTRANCE

123123

INTERVENTION

(SECLUSION)

ROOM

B1C28B1C28

TRIAGE RM

B1C31B1C31

AOD/

CHECK-IN

B1C30B1C30

MECHANICAL

ROOM

B1C17B1C17

LINEN

CLOSET

B1C41B1C41

LINEN

CLOSET

B1C42B1C42

STAIR NO.4

B1C43B1C43

ELEVATOR

EQUIP RM

B1C40B1C40

LINEN

CLOSET

B1C39B1C39

CHIEF OF ER

B1C35B1C35

HEAD NURSE

B1C37B1C37

EMS CLOSET

B1C36B1C36

CORRIDOR

B1C-1B1C-1

WAITING

B1C-1B1C-1

MALE RR

B1C33B1C33

FEMALE RR

B1C32B1C32

ELEVATOR

S-5S-5

PATIENT

COMFORT

ROOM

BC127BC127

CHARTING

ALCOVE

POLICE

DISPATCH

B1C02B1C02

CORRIDOR

B1C-5B1C-5

OBSERVATION/

TREATMENT

RM

B1C10B1C10

ELEV. EQUIP/

SUMP

178178

OBSERVATION/

TREATMENT

RM

B1C12B1C12

OBSERVATION/

TREATMENT

RM

B1C13B1C13

OBSERVATION/

TREATMENT

RM

B1C09B1C09

OBSERVATION/

TREATMENT

RM

B1C14B1C14

CORRIDOR

B1C-2B1C-2

PROCEDURE

RM

B1C05B1C05

WHEELCH.

SCALE

EXAM AREA

B1C04B1C04

EXAM AREA

B1C03B1C03

VESTIBULE

NURSE

STATION

B1C29AB1C29A

CORRIDOR

B1C-1AB1C-1A

CORRIDOR

B1C-2B1C-2

CORRIDOR

B1C-7B1C-7

CRASH CART

ALCOVE

NEW

OBSERVATION

ROOM

B1C34KB1C34K

NEW NURSES

STATION

B1C34FB1C34F

NEW

OBSERVATION

ROOM

BC24BC24

NEW

OBSERVATION

ROOM

B1C21B1C21

NEW

OBSERVATION

ROOM

B1C23B1C23

SOILED

UTILITY

B1C53B1C53

HAC

BC50BC50

CORRIDOR

B1C-9B1C-9

CLEAN

UTILITY

BC26BC26

NEW

OBSERVATION

ROOM

B1C34AB1C34A

NEW

OBSERVATION

ROOM

B1C34EB1C34E

NEW

OBSERVATION

ROOM

B1C34GB1C34G

PAT TLT

B1C34JB1C34J

HALL

B1C-6AB1C-6A

STF TLT

BC51BC51

CLEAN

UTILITY

B1C52B1C52

CORRIDOR

B1C-4B1C-4

CORRIDOR

B1C-4B1C-4

AC100B

F4

NEW NURSES

STATION

B1C34BB1C34B

1 1 1

DEDUCT ALTERNATE NO. 1:

REMOVING TERMINAL UNIT

REPLACEMENTS OUTSIDE OF

THE RENOVATION AREA

CONSTRUCTION

FENCING

DUMPSTER

AREA

CONTRACTOR STAGING YARD

E Q

E Q

EQ EQ

NEW

OBSERVATION

ROOM

B1C34CB1C34C

CORRIDOR

B1C-6B1C-6

PAT TLT

B1C25AB1C25A

EXISTING

CANOPY

TO

REMAIN

OPC

ANCILLARY

DEDUCTIVE ALTERNATE #1

REMOVE ALL ARCHITECTURAL

RENOVATION WORK

WALL TYPE LEGEND

TEMPORARY WALL

DEMOLISHED WALL, FIXTURE OR FURNISHING

EXISTING WALL, FIXTURE OR FURNISHING

NEW WALL

AREA NOT IN SCOPE

CONTRACT LIMIT

DEMOLISHED FURNITURE OR EQUIPMENT, SALVAGE TO OWNER

1. REMOVE ALL ARCHITECTURAL RENOVATION WORK

ASSOCIATED WITH THE INTERIOR EMERGENCY

DEPARTMENT BED OBSERVATION AREA, THIS

INCLUDES DEMOLITION WORK AND ALL

CONSTRUCTION WORK OUTLINED WITHIN THE "AREA

OF WORK". WORK SHOWN ON A-200, A-350, & A-351

REMAIN.

2. REMOVE ERV (ENERGY RECOVERY VENTILATOR)

FROM AHU (AIR HANDLER UNIT) SELECTION.

3. REMOVE SIGNAGE FROM ED BED OBSERVATION

SCOPE AND TRAILER COMPLETELY. IF DEDUCT ALT.1

IS EXERCISED DEDUCT ALT#3 WOULD COVER THE

REMOVAL OF SIGNAGE FROM THE TRAILER ONLY.

DEDUCTIVE ALTERNATES

NOTE: DEDUCTIVE ALTERNATES ARE NOT

CASCADING. THE OWNER WILL EXERCISE DEDUCTS

AS NEEDED. EACH DEDUCT SHALL BE PRICED UNDER

SEPARATE CLINs (CONTRACT LINE ITEM NUMBER) SO

DETERMINATIONS CAN BE MADE AND PRIORITIES

ESTABLISHED BASED ON BIDS RECEIVED.

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Mechanical, Electrical and Plumbing:

KEY PLAN

A B

D C

B

IM

/5

-1 -2

E x p a n d E

D B e d s

/5

-1

-2

.O

P C

.A R

C H

.r v t

/1

/2

:3

:2

P

M

AC100

ARCHITECTURAL REFLECTED CEILING PLAN -

LEVEL B - OVERALL - DEDUCT ALT NO.1

TRIPLE C - THE A-E GROUP

4401 Atlantic Avenue, Suite 200

Long Beach, CA 90807

562.452.7175

MAT PERKINS

REMODEL ED BEDS FOR

OBSERVATION BEDS

2615 E. CLINTON AVENUE, FRESNO, CA 93703

570-17-210

OPC

6/18/2021 M. PERKINS E. DANIELS

ISSUED FOR

CONSTRUCTION

1/8" = 1'-0" F2

ARCHITECTURAL REFLECTED CEILING PROPOSED PLAN - LEVEL B - OVERALL - DEDUCT ALT NO. 1

GENERAL SHEET NOTES

1. ACCESS TO EXISTING FIRE EXIT SHALL REMAIN OPERATIONAL DURING ALL

PHASES OF CONSTRUCTION. ENSURE ADEQUATE EGRESS CLEARANCES ARE

MAINTAINED AND NOT IMPEDED DURING PHASED CONSTRUCTION.

2. SEE GENERAL SHEETS FOR VA PROJECT NOTES, INFECTION CONTROL AND LIFE

SAFETY / CODE DATA FOR ADDITIONAL INTERIM LIFE SAFETY MEASURES AND

INFORMATION.

3. SEE A-701 FOR INTERIOR WALL TYPES.

4. SEE 'IN' SERIES DRAWINGS FOR INTERIOR DESIGN AND FINISHES.

5. SEE 'AW' SERIES DRAWINGS FOR ARCHITECTURAL SIGNAGE.

6. SEE 'Q-' SERIES DRAWINGS FOR HOSPITAL EQUIPMENT AND FURNISHINGS.

7. NO DRILLING OR JACK HAMMERING ACTIVITIES ALLOWED DURING BUSINESS

HOURS.

1 NEW GYPSUM WALLBOARD CEILING

2 NEW GYPSUM WALLBOARD SOFFIT

3 NEW 2X2 ACOUSTICAL CEILING AND GRID

4 NEW 2X4 ACOUSTICAL CEILING AND GRID

5 NEW SKYCEILING

PARTITION RATING GRAPHICS:

4 HR FIRE BARRIER

3 HR FIRE BARRIER

2 HR FIRE & SMOKE BARRIER

2 HR FIRE BARRIER

2 HR FIRE BARRIER/SHAFT

1 HR FIRE & SMOKE BARRIER

1 HR FIRE BARRIER

1 HR FIRE BARRIER/SHAFT

SMOKE PARTITION (NON RATED)

NON RATED

PARTITION RATING GRAPHIC DESIGNATION: PRIORITY

1 HIGHEST

5 LOWEST

PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH

FIRE AND SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH

HATCH PATTERNS.

S

4 5 65.A

A.1

B

B.1

C

D

E

INTERVENTION

(SECLUSION)

ROOM

B1C28B1C28

MECHANICAL

ROOM

B1C17B1C17

LINEN

CLOSET

B1C41B1C41

LINEN

CLOSET

B1C42B1C42

STAIR

NO.4

B1C43B1C43

LINEN

CLOSET

B1C39B1C39

CHIEF

OF ER

B1C35B1C35

HEAD

NURSE

B1C37B1C37

EMS

CLOSET

B1C36B1C36

MALE

RR

B1C33B1C33

ELEVATOR

S-5S-5

PATIENT

COMFORT

ROOM

BC127BC127

CORRIDOR

B1C-2B1C-2

CORRIDOR

B1C-4B1C-4

MECHANICAL

ROOM

B1C17B1C17

NEW

OBSERVATION

ROOM

B1C23B1C23

CLEAN

UTILITY

B1C52B1C52

LINEN

CLOSET

B1C41B1C41

LINEN

CLOSET

B1C42B1C42

STAIR

NO.4

B1C43B1C43

ELEVATOR

EQUIP

RM

B1C40B1C40

LINEN

CLOSET

B1C39B1C39

CHIEF

OF ER

B1C35B1C35

EMS

CLOSET

B1C36B1C36

CORRIDOR

B1C-1B1C-1

WAITING

B1C-1B1C-1

FEMALE

RR

B1C32B1C32

NEW

OBSERVATION

ROOM

B1C34KB1C34K

NEW

NURSES

STATION

B1C34FB1C34F

NEW

OBSERVATION

ROOM

B1C34AB1C34A

ELEVATOR

S-6S-6

HALL

B1C-6AB1C-6A

NEW

OBSERVATION

ROOM

B1C21B1C21

PATIENT

COMFORT

ROOM

BC127BC127

OBSERVATION/

TREATMENT

RM

B1C14B1C14

SOILED

UTILITY

B1C53B1C53

CORRIDOR

B1C-2B1C-2

HAC

BC50BC50

CORRIDOR

B1C-7B1C-7

NURSE

STATION

B1C29AB1C29A

CRASH

CART

ALCOVE

8'-0"

8'-0" 8'-0"

8'-0" 8'-0"

AREA OF WORK

NEW

OBSERVATION

ROOM

B1C34CB1C34C

NEW

OBSERVATION

ROOM

B1C34EB1C34E

NEW

OBSERVATION

ROOM

B1C34GB1C34G

PAT TLT

B1C34JB1C34J

NEW

STORAGE

B1C34HB1C34H

STF TLT

BC51BC51

PAT TLT

B1C25AB1C25A

NEW

OBSERVATION

ROOM

BC24BC24

8'-0"

7'-10"

1'-8"

8'-0"

8'-0"

8'-0"

8'-0"

8'-0"

7'-6"

7'-6"

8'-0"

8'-0"

8'-0"

7'-10"

8'-0"

8'-0"

7'-10"F7

A-511

F7

A-511

8'-0"

7'-10"

8'-0"

8'-0"

7' -1

0" 7'

-1 0"

7' -1

0" 4'

-1 0"

5' -6

6' -6

NEW

NURSES

STATION

B1C34BB1C34B

7'-4"

8'-0"

6"

B5

A-701

SIM

B5

A-701

SIM

CLEAN

UTILITY

BC26BC26

CORRIDOR

B1C-4B1C-4

CORRIDOR

B1C-2B1C-2

CORRIDOR

B1C-6B1C-6

C1

A-511

C1

A-511

4'-4" 4'-4 3/8" 4'-5 1/4"

5'-6"

5'-7"

4'-6"

1'-4" 5'-6" 1'-11" 5'-4"

2'-5"

3' -9

1'-5" 5'-4"

3' -0

2' -0

" 3' -1

4' -6

1'-7"

3'-9"

4' -7

" 1'-0"

5' -7

6'

-0

6' -0

6'

-0

6' -0

6'

-0

2' -1

2'-8"

1'-0"

1' -4

3'-7"

3' -6

1'-8" 4'-0"

2'-4" 2'-3"

3'-9"

1' -2

3' -2

3'

-6

2'-3"

2'-4"

2' -1

1"

1' -4

2'-2"

2' -1

1"

2' -3

E4

A-511

E4

A-511

A1165

A1200

A1165

A1200

A1165

A1200

A1165

A1165

A1165

A1165

A1165

A5180 A5180 A5180

A5180

A5180

A5180

A5180

A5180

7"

8"

8"

7"

4' -8

'-0

NEW

STORAGE

B1C34DB1C34D

PAT

SHWR

B1C25BB1C25B

CORRIDOR

B1C-4B1C-4

4' -5

2'

-2

9' -1

6'

-6

7' -1

0" 5'

-5

8'-0"

5"5"

7'-10"

RCP SYMBOL LEGEND

RECESSED OR SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE

SMOKE DETECTOR

SPEAKER

HVAC SUPPLY DIFFUSER

HVAC RETURN DIFFUSER

EXIT LIGHT

HEAT DETECTOR

HVAC EXHAUST DIFFUSER

RECESSED OR SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE

ACOUSTICAL TILE CEILING (24X24)

AT-1

ACOUSTICAL TILE CEILING (24X48)

AT-2

GYPSUM CEILING - PAINTED

CEILING MOUNTED PATIENT LIFT (VA (VV) PROVIDED AND

INSTALLED)

CEILING MOUNTED IV TRACK

SKYFACTORY CEILING PANELS AT-3

ACCESS PANEL

LED RECESSED STRIP LIGHTING

RECESSED DOWN LIGHT FIXTURE - INSTALL CENTERED IN

ACOUSTICAL CEILING TILE UNO

(P-1 UNO)

SPRINKLER

WALL TYPE LEGEND

TEMPORARY WALL

DEMOLISHED WALL, FIXTURE OR FURNISHING

EXISTING WALL, FIXTURE OR FURNISHING

NEW WALL

AREA NOT IN SCOPE

CONTRACT LIMIT

DEMOLISHED FURNITURE OR EQUIPMENT, SALVAGE TO OWNER

1. REMOVE ALL ARCHITECTURAL RENOVATION WORK

ASSOCIATED WITH THE INTERIOR EMERGENCY

DEPARTMENT BED OBSERVATION AREA, THIS

INCLUDES DEMOLITION WORK AND ALL

CONSTRUCTION WORK OUTLINED WITHIN THE "AREA

OF WORK". WORK SHOWN ON A-200, A-350, & A-351

REMAIN.

2. REMOVE ERV (ENERGY RECOVERY VENTILATOR)

FROM AHU (AIR HANDLER UNIT) SELECTION.

3. REMOVE SIGNAGE FROM ED BED OBSERVATION

SCOPE AND TRAILER COMPLETELY. IF DEDUCT ALT.1

IS EXERCISED DEDUCT ALT#3 WOULD COVER THE

REMOVAL OF SIGNAGE FROM THE TRAILER ONLY.

DEDUCTIVE ALTERNATES

NOTE: DEDUCTIVE ALTERNATES ARE NOT

CASCADING. THE OWNER WILL EXERCISE DEDUCTS

AS NEEDED. EACH DEDUCT SHALL BE PRICED UNDER

SEPARATE CLINs (CONTRACT LINE ITEM NUMBER) SO

DETERMINATIONS CAN BE MADE AND PRIORITIES

ESTABLISHED BASED ON BIDS RECEIVED.

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Mechanical, Electrical and Plumbing:

KEY PLAN

B

B

IM

/5

-1 -2

E x p a n d E

D B e d s

/5

-1

-2

.O

P C

.A R

C H

.r v t

/1

/2

:3

:3

P

M

AC100B

ARCHITECTURAL REFLECTED CEILING PLAN -

LEVEL B - AREA B - DEDUCT ALT NO.1

TRIPLE C - THE A-E GROUP

4401 Atlantic Avenue, Suite 200

Long Beach, CA 90807

562.452.7175

MAT PERKINS

REMODEL ED BEDS FOR

OBSERVATION BEDS

2615 E. CLINTON AVENUE, FRESNO, CA 93703

570-17-210

OPC

6/18/2021 M. PERKINS E. DANIELS

ISSUED FOR

CONSTRUCTION

GENERAL SHEET NOTES

1. ACCESS TO EXISTING FIRE EXIT SHALL REMAIN OPERATIONAL DURING ALL

PHASES OF CONSTRUCTION. ENSURE ADEQUATE EGRESS CLEARANCES ARE

MAINTAINED AND NOT IMPEDED DURING PHASED CONSTRUCTION.

2. SEE GENERAL SHEETS FOR VA PROJECT NOTES, INFECTION CONTROL AND LIFE

SAFETY / CODE DATA FOR ADDITIONAL INTERIM LIFE SAFETY MEASURES AND

INFORMATION.

3. SEE A-701 FOR INTERIOR WALL TYPES.

4. SEE 'IN' SERIES DRAWINGS FOR INTERIOR DESIGN AND FINISHES.

5. SEE 'AW' SERIES DRAWINGS FOR ARCHITECTURAL SIGNAGE.

6. SEE 'Q-' SERIES DRAWINGS FOR HOSPITAL EQUIPMENT AND FURNISHINGS.

7. NO DRILLING OR JACK HAMMERING ACTIVITIES ALLOWED DURING BUSINESS

HOURS.

1/4" = 1'-0" F4

ARCHITECTURAL REFLECTED CEILING PLAN - LEVEL B - AREA B - DEDUCT ALT NO.1

1 ALIGN FACE OF WALLS

2 CUBICLE CURTAIN TRACK SYSTEM (CC-1) PROVIDED BY

CONTRACTOR, DISPOSABLE FABRIC CURTAIN SYSTEM PROVIDED

BY OWNERS' FACILITY DEPARTMENT, REFER TO IN601 FOR

CEILING TRACK INFORMATION

3 SKYCEILING, REFER TO IN601 FOR ADDITIONAL INFORMATION

4 PAINT ALL EXPOSED SIDES OF GYPSUM SOFFIT P-3, REFER TO

IN601 FOR ADDITIONAL INFO

5 PAINT ALL EXPOSED SIDES OF GYPSUM SOFFIT P-2, REFER TO

IN601 FOR ADDITIONAL INFO

PARTITION RATING GRAPHICS:

4 HR FIRE BARRIER

3 HR FIRE BARRIER

2 HR FIRE & SMOKE BARRIER

2 HR FIRE BARRIER

2 HR FIRE BARRIER/SHAFT

1 HR FIRE & SMOKE BARRIER

1 HR FIRE BARRIER

1 HR FIRE BARRIER/SHAFT

SMOKE PARTITION (NON RATED)

NON RATED

PARTITION RATING GRAPHIC DESIGNATION: PRIORITY

1 HIGHEST

5 LOWEST

PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH

FIRE AND SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH

HATCH PATTERNS.

4 5 65.A

A.1

B

B.1

C

D

E

TRIAGE

RM

B1C28B1C28

LINEN

CLOSET

B1C41B1C41

LINEN

CLOSET

B1C42B1C42

STAIR

NO.4

B1C43B1C43

ELEVATOR

EQUIP

RM

B1C40B1C40

LINEN

CLOSET

B1C50B1C50

POLICE

CHIEF

OFFICE

B1C35B1C35

PUBLIC

AFFAIRS

B1C37B1C37

EMS

CLOSET

B1C36B1C36

CORRIDOR

B1C-1B1C-1

CLOSET

B1C34DB1C34D

MALE

RR

B1C33B1C33

FEMALE

RR

B1C32B1C32

ELEVATOR

S-5S-5

ELEVATOR

S-6S-6

OBS

BEDS

ROOM

B1C-6AB1C-6A

CORRIDOR

B1C-6B1C-6

PATIENT

COMFORT

ROOM

B1C27B1C27

HEAD

NURSE

B1C53B1C53

CLOSET

SPD

B1C51B1C51

OBSERVATION/

TREATMENT

RM

B1C14B1C14

TOILET

B1C24B1C24

OBSERVATION/

TREATMENT

RM

B1C23B1C23

CORRIDOR

B1C-2B1C-2

NURSE

B1C34AB1C34A

AREA OF WORK

1. REMOVE ALL ARCHITECTURAL RENOVATION WORK

ASSOCIATED WITH THE INTERIOR EMERGENCY

DEPARTMENT BED OBSERVATION AREA, THIS

INCLUDES DEMOLITION WORK AND ALL

CONSTRUCTION WORK OUTLINED WITHIN THE "AREA

OF WORK". WORK SHOWN ON A-200, A-350, & A-351

REMAIN.

2. REMOVE ERV (ENERGY RECOVERY VENTILATOR)

FROM AHU (AIR HANDLER UNIT) SELECTION.

3. REMOVE SIGNAGE FROM ED BED OBSERVATION

SCOPE AND TRAILER COMPLETELY. IF DEDUCT ALT.1

IS EXERCISED DEDUCT ALT#3 WOULD COVER THE

REMOVAL OF SIGNAGE FROM THE TRAILER ONLY.

DEDUCTIVE ALTERNATES

NOTE: DEDUCTIVE ALTERNATES ARE NOT

CASCADING. THE OWNER WILL EXERCISE DEDUCTS

AS NEEDED. EACH DEDUCT SHALL BE PRICED UNDER

SEPARATE CLINs (CONTRACT LINE ITEM NUMBER) SO

DETERMINATIONS CAN BE MADE AND PRIORITIES

ESTABLISHED BASED ON BIDS RECEIVED.

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Mechanical, Electrical and Plumbing:

KEY PLAN

B

B

IM

/5

-1 -2

E x p a n d E

D B e d s

/5

-1

-2

.O

P C

.A R

C H

.r v t

/1

/2

:3

:3

P

M

AC100B-3

ARCHITECTURAL REFLECTED CEILING PLAN -

LEVEL B - AREA B - DEDUCT ALT NO.1

TRIPLE C - THE A-E GROUP

4401 Atlantic Avenue, Suite 200

Long Beach, CA 90807

562.452.7175

MAT PERKINS

REMODEL ED BEDS FOR

OBSERVATION BEDS

2615 E. CLINTON AVENUE, FRESNO, CA 93703

570-17-210

OPC

6/18/2021 M. PERKINS K.

MCDERMOTT

ISSUED FOR

CONSTRUCTION

1/4" = 1'-0" F4

ARCHITECTURAL REFLECTED CEILING PLAN - LEVEL B - AREA B (EXISTING LAYOUT) DEDUCT ALT NO.1

GENERAL SHEET NOTES

1. ACCESS TO EXISTING FIRE EXIT SHALL REMAIN OPERATIONAL DURING ALL

PHASES OF CONSTRUCTION. ENSURE ADEQUATE EGRESS CLEARANCES ARE

MAINTAINED AND NOT IMPEDED DURING PHASED CONSTRUCTION.

2. SEE GENERAL SHEETS FOR VA PROJECT NOTES, INFECTION CONTROL AND LIFE

SAFETY / CODE DATA FOR ADDITIONAL INTERIM LIFE SAFETY MEASURES AND

INFORMATION.

3. SEE A-701 FOR INTERIOR WALL TYPES.

4. SEE 'IN' SERIES DRAWINGS FOR INTERIOR DESIGN AND FINISHES.

5. SEE 'AW' SERIES DRAWINGS FOR ARCHITECTURAL SIGNAGE.

6. SEE 'Q-' SERIES DRAWINGS FOR HOSPITAL EQUIPMENT AND FURNISHINGS.

7. NO DRILLING OR JACK HAMMERING ACTIVITIES ALLOWED DURING BUSINESS

HOURS.

PARTITION RATING GRAPHICS:

4 HR FIRE BARRIER

3 HR FIRE BARRIER

2 HR FIRE & SMOKE BARRIER

2 HR FIRE BARRIER

2 HR FIRE BARRIER/SHAFT

1 HR FIRE & SMOKE BARRIER

1 HR FIRE BARRIER

1 HR FIRE BARRIER/SHAFT

SMOKE PARTITION (NON RATED)

NON RATED

PARTITION RATING GRAPHIC DESIGNATION: PRIORITY

1 HIGHEST

5 LOWEST

PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH

FIRE AND SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH

HATCH PATTERNS.

KEYNOTES

1 DEDUCTIVE ALTERNATE NO. 1, THIS AREA IS EXISTING TO REMAIN.

OMIT DEMOLITION AND SCOPE OF WORK OUTLINED WITHIN 'AREA

OF WORK'

Revisions: Date:

IF DEDUCTIVE ALTERNATE #1

IS EXERCISED CEILING

LAYOUT WILL REMAIN IN THE

EXISTING LAYOUT SHOWN

HERE.

AA.1BB.1CDEBOPC.FBOPC.G

F5

A-350

F5

A-350

TEMP DUCT

ROUTE REM

FOR CLARITY

01_FIRST FLOOR_OPC

100' - 0"

02_SECOND FLOOR

OPC

113' - 6"

A

03_ROOF OPC

139' - 6"

03_TOP OF PARAPET

143' - 6"

00_BASEMENT_OPC

88' - 0"

PENTHOUSE OPC

139' - 6"

03_THIRD FLOOR OPC

125' - 6"

A.1 B B.1 C D E BOPC.F BOPC.G

04_PENTHOUSE ROOF

155' - 6"

05_TOP OF

PENTHOUSE PARAPET

156' - 2"

00_MECHANICAL

ROOM

83' - 0"

01_B18_FIRST FLOOR

96' - 9 19/32"

02_B18_ROOF

108' - 9 19/32"

F5

A-350

F5

A-350

TEMP DUCT

ROUTE REM FOR

CLARITY

01_FIRST FLOOR_OPC

100' - 0"

02_SECOND FLOOR

OPC

113' - 6"

BOPC.1

03_ROOF OPC

139' - 6"

03_TOP OF PARAPET

143' - 6"

00_BASEMENT_OPC

88' - 0"

PENTHOUSE OPC

139' - 6"

03_THIRD FLOOR OPC

125' - 6"

BOPC.2 BOPC.3 4 5 65.A

04_PENTHOUSE ROOF

155' - 6"

05_TOP OF

PENTHOUSE PARAPET

156' - 2"

00_MECHANICAL

ROOM

83' - 0"

01_B18_FIRST FLOOR

96' - 9 19/32"

02_B18_ROOF

108' - 9 19/32"

F7

A-350

F7

A-350

'-0

M

IN

IM

U M

30'-0" MINIMUM

3 4

5 6

TEMP DUCT

ROUTE REM

FOR CLARITY

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Mechanical, Electrical and Plumbing:

B

IM

/5

-1 -2

E x p a n d E

D B e d s

/5

-1

-2

.O

P C

.A R

C H

.r v t

/1

/2

:3

:1

P

M

A-200

PROPOSED BUILDING ELEVATIONS

TRIPLE C - THE A-E GROUP

4401 Atlantic Avenue, Suite 200

Long Beach, CA 90807

562.452.7175

MAT PERKINS

REMODEL ED BEDS FOR

OBSERVATION BEDS

2615 E. CLINTON AVENUE, FRESNO, CA 93703

570-17-210

OPC

6/18/2021 M. PERKINS E. DANIELS

ISSUED FOR

CONSTRUCTION

1/8" = 1'-0" F7

EXTERIOR ELEVATION - EAST

1/8" = 1'-0"

F1

EXTERIOR ELEVATION - WEST

1/8" = 1'-0" C4

EXTERIOR ELEVATION - SOUTH

GENERAL SHEET NOTES

1. ACCESS TO EXISTING FIRE EXIT SHALL REMAIN OPERATIONAL DURING ALL

PHASES OF CONSTRUCTION. ENSURE ADEQUATE EGRESS CLEARANCES ARE

MAINTAINED AND NOT IMPEDED DURING PHASED CONSTRUCTION.

KEYNOTES

1 NEW EXHAUST DUCT ENCLOSURE FOR BASEMENT EXHAUST AIR. STUCCO TO

MATCH EXISTING, BASE BID. REFER TO STRUCTURAL FOR MORE INFORMATION.

2 FUTURE EXHAUST DUCT ENCLOSURE FOR 1ST FLOOR EXHAUST AIR (NIC)

3 NEW SPECIAL EXHAUST FAN SERVING NEGATIVE PRESSURE TREATMENT ROOMS

ON BASEMENT FLOOR, EF-1

4 NEW GENERAL EXHAUST FAN SERVING BASEMENT FLOOR, EF-ED

5 NEW OUTSIDE AIR INTAKE LOUVERED PENTHOUSE

6 EXISTING INTAKE HOOD TO REMAIN

01_FIRST FLOOR_OPC

100' - 0"

03_ROOF OPC

139' - 6"

03_TOP OF PARAPET

143' - 6"

00_BASEMENT_OPC

88' - 0"

PENTHOUSE OPC

139' - 6"

03_THIRD FLOOR OPC

125' - 6"

BOPC.G

00_MECHANICAL

ROOM

83' - 0"

F5

A-350

F5

A-350

A-350

F1

A-350

F3

A-350

D1

A-350

A1

A-350

B3

SIM

A-350

C1

02_SECOND FLOOR OPC SIM.

DEMO SUN SHADE TO VERTICAL STUDS

DEMO SUN SHADE TO VERTICAL STUDS

2'-3 1/2"

NEW METAL STUD ANGLE, FASTEN TO EXISTING

VERTICAL AND HORIZONTAL STUDS

NEW METAL STUD ANGLE, FASTEN TO EXISTING

VERTICAL AND HORIZONTAL STUDS

SIM

A-350

C1

7' -2

/8

5'

-0

ALIGN STUDS

01_FIRST FLOOR_OPC

100' - 0"

03_ROOF OPC

139' - 6"

03_TOP OF PARAPET

143' - 6"

00_BASEMENT_OPC

88' - 0"

PENTHOUSE OPC

139' - 6"

03_THIRD FLOOR OPC

125' - 6"

00_MECHANICAL

ROOM

83' - 0"

F7

A-350

F7

A-350

3' -0

1/ 2"

1/ 2"

SIM

A-350

F1

SIM

A-350

F1

SIM

A-350

C1

SIM

A-350

C1

02_SECOND FLOOR OPC SIM.

A-350

C3

SIM

A-350

C1

SIM

A-350

C1

SIM

A-350

A1

7' -3

5' -0

BOPC.G

F5

A-350

F5

A-350

NEW HSS6X6X1/4 SUPPORT FRAME

CUT EXISTING METAL GRATE AT

NEW ENCLOSURE PROVIDE MIN

3/8" GAP

NEW L6X3.5X5/16

SUPPORT FOR NEW

END OF METAL

GRATE

L3X3X1/4X5" W/ (2) 5/8" DIA EXPANTION

BOLT W/ 6" EMBEDMENT EACH SIDE

AND EACH END

SEE C1/A-350 FOR

TYPICAL NOTES

03_TOP OF PARAPET

143' - 6"

BOPC.G

SEE C1/A-350 FOR

TYPICAL NOTES

BASE OF WALL THRU-WALL

FLASHING, W/ HEMMED EDGE &

CONTINOUS KEEPER

GAP

THRU-WALL FLASHING, W/ END

DAMS, HEMMED EDGE &

CONTINOUS KEEPER

SILL SEALER MATERIAL &

SEALANT AND BACKER ROD

1/ 4"

BOPC.G

SEALANT & BACKROD

PRE-FINISHED J-CHANNEL

1" X 12" METAL SOFFIT PANELS

2" OF INSULATION R-VALUE 4

PER INCH & 2" Z-FURRING

CHANNEL

4" METAL STUD PER 05 40 00

WITH R-13 BATT INSULATION &

BATT RETENTION STRAPS

5/8" EXTERIOR GYP SHEATHING

AIR & WEATHER BARRIER

3/8"CONTINOUS KEEPER & SOFFIT TRIM

WITH SOFFIT RECIEVER

1" X 12" METAL SOFFIT PANELS

BASE OF WALL THRU-WALL

FLASHING, W/ HEMMED EDGE

GAP

EIFS

DRAINAGE STRIP AND TRANSITION

MEMBRANE

1/ 4"

BOPC.G

EXHAUST DUCT NOSAL

SEAL JOINT W/ WATER CUTOFF

MASTIC

CUSTOM CAP WITH INSULATED

ROOF CURB

PRE-FIN ALUM ROOF CAP

FLASHING WITH HEMMED

EDGED AND CONTINOUS

KEEPER.

SEE C1/A-350 FOR

TYPICAL NOTES

CANT

GRAVEL STOP

3/4" PLYWOOD WITH PEAL AND STICK

MEMBRANE

SEE C1/A-350 FOR

TYPICAL NOTES

EXHAUST DUCT NOSAL

SEAL JOINT W/ WATER CUTOFF

MASTIC

CUSTOM CAP WITH INSULATED

ROOF CURB

PRE-FIN ALUM ROOF CAP

FLASHING WITH HEMMED

EDGED AND CONTINOUS

KEEPER.

CANT

GRAVEL STOP BEYOUND

3/4" PLYWOOD WITH PEAL AND STICK

MEMBRANE

PROVIDE SPIRAL MFG (OR APPROVED EQUAL) SKY

BLAST WEATHERHOOD, STORM COLLAR AND

FLASHING, SEE MECHANICAL SHEETS FOR DETAILS.

03_THIRD FLOOR OPC

125' - 6"

EIFS

6" METAL STUD PER 05 40 00

WITH R-13 BATT INSULATION &

BATT RETENTION STRAPS

HSS6X6X1/4 SUPPORT FRAME

5/8" EXTERIOR GYP SHEATHING

2" OF INSULATION R-VALUE 4 PER

INCH

AIR & WEATHER BARRIER

BRACE FRAMING L6X3.5X5/16

DUCT, SEE MECH

SEE C1/A-350 FOR

TYPICAL NOTES

DUCTWORK

DUCT COLLAR

THRU-WALL FLASHING, W/

HEMMED EDGE

GAP

OVERLAP WEATHER BARRIER

OVER DUCT COLLAR AND

THRU-WALL FLASHING

1/ 4"

A-722

C7

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Mechanical, Electrical and Plumbing:

B

IM

/5

-1 -2

E x p a n d E

D B e d s

/5

-1

-2

.O

P C

.A R

C H

.r v t

/1

/2

:3

:2

P

M

A-350

EXTERIOR WALL SECTIONS & DETAILS

TRIPLE C - THE A-E GROUP

4401 Atlantic Avenue, Suite 200

Long Beach, CA 90807

562.452.7175

MAT PERKINS

REMODEL ED BEDS FOR

OBSERVATION BEDS

2615 E. CLINTON AVENUE, FRESNO, CA 93703

570-17-210

OPC

6/18/2021 M. PERKINS E. DANIELS

ISSUED FOR

CONSTRUCTION

1/2" = 1'-0" F7

EXTERIOR EXHAUST DUCT ENCLOSURE SECTION

1/2" = 1'-0"

F5

EXTERIOR EXHAUST DUCT ENCLOSURE CROSS SECTION

1 1/2" = 1'-0" D1

DETAIL AT STEEL SUPPORT

1 1/2" = 1'-0" B3

DETAIL AT EXISTING PARAPET

1 1/2" = 1'-0" F3

SOFFIT DET AT EXISTING WALL

1 1/2" = 1'-0"

F1

SOFFIT DET AT VERTICAL WALL

1 1/2" = 1'-0" A1

TOP OF EXTERIOR EXHAUST DUCT ENCLOSURE DETAIL

1 1/2" = 1'-0" C1

TYPICAL PANEL DETAIL

1" = 1'-0"

C3

EXTERIOR WALL DUCTWORK DETAIL

BOPC.G

F7

A-350

F5

A-350

A-351

F6

A-351

F4 ø 3'-0"

BOPC.G

F7

A-350

F5

A-350

A-351

D6 ø 3'-0"

5' -8

/4

4'-10"

BOPC.G

F7

A-350

F5

A-350

A-351

B6

A-351

B4

EIFS

6" METAL STUD PER 05 40 00

WITH R-13 BATT INSULATION &

BATT RETENTION STRAPS

HSS6X6X1/4

SUPPORT

FRAME

5/8" EXTERIOR GYP SHEATHING

AIR & WEATHER BARRIER

DUCT, SEE

MECH

2" OF INSULATION R-VALUE 4 PER

INCH

EXISTING METAL GRATE

BOPC.G

1/ 2"

EFIS5/8" EXTERIOR GYP

SHEATHING

AIR & WEATHER BARRIER

2" INSULATION R-VALUE 4 PER INCH

6" METAL STUD PER 05 40

WITH R-13 BATT

INSULATION & BATT

RETENTION STRAPS

EXISTING WALL

SEALANT AND BACKER ROD

METAL FLASHING

BOPC.G

1/ 2"

EIFS5/8" EXTERIOR GYP

SHEATHING

AIR & WEATHER BARRIER

2" INSULATION R-VALUE 4 PER INCH

6" METAL STUD PER 05 40 00

WITH R-13 BATT INSULATION

& BATT RETENTION STRAPS

EXISTING WALL

SEALANT AND BACKER ROD

METAL FLASHING

EXISTING WINDOW FRAME

BOPC.G

EXISTING ROOF BELOW

EXISTING PARAPET COPING

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Mechanical, Electrical and Plumbing:

B

IM

/5

-1 -2

E x p a n d E

D B e d s

/5

-1

-2

.O

P C

.A R

C H

.r v t

/1

/2

:3

:2

P

M

A-351

EXTERIOR ENLARGED PLANS & DETAILS

TRIPLE C - THE A-E GROUP

4401 Atlantic Avenue, Suite 200

Long Beach, CA 90807

562.452.7175

MAT PERKINS

REMODEL ED BEDS FOR

OBSERVATION BEDS

2615 E. CLINTON AVENUE, FRESNO, CA 93703

570-17-210

OPC

6/18/2021

ISSUED FOR

CONSTRUCTION

1/2" = 1'-0" F8

EXTERIOR EXHAUST DUCT ENCLOSURE PLAN - FIRST FLOOR

1/2" = 1'-0" D8

EXTERIOR EXHAUST DUCT ENCLOSURE PLAN - SECOND FLOOR

1/2" = 1'-0" B8

EXTERIOR EXHAUST DUCT ENCLOSURE PLAN - ROOF

1 1/2" = 1'-0" F6

PLAN DETAIL AT OUTSIDE CORNER

1 1/2" = 1'-0"

F4

PLAN DETAIL AT EXISTING WALL

1 1/2" = 1'-0" D6

PLAN DETAIL AT EXISTING WINDOW

1 1/2" = 1'-0" B6

PLAN DETAIL AT DUCT PENETRATION

1 1/2" = 1'-0"

B4

PLAN DETAIL AT ROOF

custom fab insulated curb with cap flashing

RB-1

6"

M7415

M7845

M7040

F0725M

5' -0

5' -5

A1200

8' -0

A1110

11" 11 3/4"

6' -0

A5107

RB-1

8' -0

2' -9

3' -6

4' -0

4' -6

1'-4" 1'-10" 11" 1'-0"

1'-10"

A5082

A5075

P3100

A1200 M0013

A5108

F0210M

A5140

WFT-1

WFT-1

EQ EQ

W F

T -1

4' -6

A1200

11"

3RB-1

5' -0

M4655

F0725M

M7845

A1200

A1132 M4200 M4100 A5107

5' -5

WFT-7

1'-5"1'-11"1'-5"2'-1"

4' -6

1' -3

4'-4"A1165

PL-1 PL-1

A-401B

B4

B

NEW

OBSERVATION

ROOM

B1C23

83 SF

B 1C

A5180

F0725M

M7845 F0210M

M4655

M7040

P3100

A5075

A5082

F2010

M0013

A5108

A1200

A5140

A5

A6

WFT-1

A 6 1'-5" 1'-11" 1'-5"

4'-4" A

A-401 C

C

SOILED

UTILITY

B1C53B1C53

B 1C

WFT-3

A

A6

A

P6350

F2020 M3072 M3070

P2451

P2000

A5075 P3100

A5082

A5107A1012

CT050

CS200

A5075

A5082

3' -5

2'

-5

5' -1

0"

1'-0" 1'-2" 1'-3"

2'-0"

A5082

A5075

P2000

P3100P2451

A5107 8' -0

2' -9

3' -6

1'-9"

W F

T -3

4' -6

RB-1

WFT-3

1'-6"

8" 7"1'-5"

M3070

P6350

A5082

CT050

CS200

A5075

A1012

2' -1

0"

8' -0

W F

T -3

4' -6

2' -9

RB-1

WFT-3

1'-3"1'-4" 9"

3' -4

3'

-6

F6

A-512

SS-1

A-401

D6

D

D

STF TLT

BC51

53 SF

P3100 A1067

A5075

A5082

P9050

A5109

A5090A5200

WFT-4

ALL WALLS

A

E

A

A

A6

A5109F2017M

3'-4"

2' -1

1"

1' -6

2' -1

2' -4

2'-0"1'-0"2'-0"

2' -9

2' -6

1' -0

" 4" 8' -0

A5082

F2017M

A1067

A5075

P3100

A5090

A5200

A5109

WFT-4

W F

T -4

4' -6

3' -6

3' -4

1'-0"

3'-6"

1'-6"

6" 3'-0"

8' -0

1' -6

"2' -1

1"

A5109

A5200 A5090

WFT-4

2' -1

2' -4

"W F

T -4

4' -6

P9050

2' -6

2' -9

3' -6

3' -4

1'-4" 1'-6"

A1067

A5082A5075

P3100

F2017M

WFT-41

8'

-0

EQUIPMENT LEGEND

V V ITEM - VA SUPPLIED & INSTALLED

V C ITEM - VA SUPPLIED &

CONTRACTOR INSTALLED

C C ITEM - CONTRACTOR SUPPLIED &

INSTALLED

FURNITURE, FIXTURE, & EQUIPMENT

INDICATOR

A1000

PAT TLT

B1C25A

67 SF

PAT

SHWR

B1C25B

16 SF

B1C25A

A-401

F6

F

F2

F

M8000

A4995

A5109

P9050

A5090

A5075

A1067

P3100

A5082F2017MA5077

A6

A

A4

A4

A

A8

A5030

A5110A5110

A5200

S

LO

P E

6W F

T -6

5' -5

W

F T

-5

WFT-5

W F

T -5

WFT-5

WFT-6

W F

T -6

WFT-5

7" 1'-6" 11"

2' -9

6"

8" 10" 1'-3" 1'-3" 8"

2' -9

2' -6

3' -4

1'-3" 1'-6"

1' -6

2' -4

" W F

T -5

4' -6

M8000

A5109A5109

P9050

A5090

A5075 A1067

P3100 F2017M

WFT-6

W F

T -6

8' -0

8' -0

A5110A5110

2' -1

A5200

WFT-5

W F

T -5

4' -6

2' -9

2' -6

3' -4

3' -6

2'-3"1'-4"1'-2"1'-0"

A1067

A5075 A5082

A5077F2017M P3100

8' -0

A4995

WFT-5

2' -2

"W F

T -5

4' -6

A49958' -0

WFT-6

1' -6

W F

T -6

8' -0

A5030

B 1C

A

1'-6"

CL

1' -6

" 2' -9

3' -3

1' -6

M8000 A5109

P9050

WFT-5

W F

T -5

4' -6

WFT-6

8' -0

A5110A5110

A5030

PATTERN CHANGE (REFER TO IF601 FOR

TRANSITION DETAILS)

MATERIAL FLOOR CHANGE (REFER TO IF601 FOR

TRANSITION DETAILS)

DIRECTION OF FINISH

INTERIOR FINISH SYMBOLS

P-_ PAINT COLOR / WALL FINISHES

EXTENT OF WALL FINISH TYPE

CORNER GUARD LOCATIONCG

GRAIN

HANDRAIL LOCATION

ROOM FINISH TAG

Wall Finish

Base Finish Floor Finish

WALL GUARD LOCATION

WG

1. REMOVE ALL ARCHITECTURAL RENOVATION WORK

ASSOCIATED WITH THE INTERIOR EMERGENCY

DEPARTMENT BED OBSERVATION AREA, THIS

INCLUDES DEMOLITION WORK AND ALL

CONSTRUCTION WORK OUTLINED WITHIN THE "AREA

OF WORK". WORK SHOWN ON A-200, A-350, & A-351

REMAIN.

2. REMOVE ERV (ENERGY RECOVERY VENTILATOR)

FROM AHU (AIR HANDLER UNIT) SELECTION.

3. REMOVE SIGNAGE FROM ED BED OBSERVATION

SCOPE AND TRAILER COMPLETELY. IF DEDUCT ALT.1

IS EXERCISED DEDUCT ALT#3 WOULD COVER THE

REMOVAL OF SIGNAGE FROM THE TRAILER ONLY.

DEDUCTIVE ALTERNATES

NOTE: DEDUCTIVE ALTERNATES ARE NOT

CASCADING. THE OWNER WILL EXERCISE DEDUCTS

AS NEEDED. EACH DEDUCT SHALL BE PRICED UNDER

SEPARATE CLINs (CONTRACT LINE ITEM NUMBER) SO

DETERMINATIONS CAN BE MADE AND PRIORITIES

ESTABLISHED BASED ON BIDS RECEIVED.

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Mechanical, Electrical and Plumbing:

KEY PLAN

B

B

IM

/5

-1 -2

E x p a n d E

D B e d s

/5

-1

-2

.O

P C

.A R

C H

.r v t

/1

/2

:3

:3

P

M

A-401

ARCHITECTURAL ENLARGED VIEWS - DEDUCT

ALT NO.1

TRIPLE C - THE A-E GROUP

4401 Atlantic Avenue, Suite 200

Long Beach, CA 90807

562.452.7175

MAT PERKINS

REMODEL ED BEDS FOR

OBSERVATION BEDS

2615 E. CLINTON AVENUE, FRESNO, CA 93703

570-17-210

OPC

6/18/2021 M. PERKINS N.

BLANCHARD

ISSUED FOR

CONSTRUCTION

1/4" = 1'-0" B2

OBSERVATION ROOM - WEST

ELEVATION

1/4" = 1'-0" B6

OBSERVATION ROOM - EAST ELEVATION

1/4" = 1'-0"

B4

OBSERVATION ROOM - SOUTH ELEVATION

GENERAL SHEET NOTES

1. ACCESS TO EXISTING FIRE EXIT SHALL REMAIN OPERATIONAL DURING ALL

PHASES OF CONSTRUCTION. ENSURE ADEQUATE EGRESS CLEARANCES ARE

MAINTAINED AND NOT IMPEDED DURING PHASED CONSTRUCTION.

2. SEE GENERAL SHEETS FOR VA PROJECT NOTES, INFECTION CONTROL AND LIFE

SAFETY / CODE DATA FOR ADDITIONAL INTERIM LIFE SAFETY MEASURES AND

INFORMATION.

3. SEE A-701 FOR INTERIOR WALL TYPES.

4. SEE 'IN' SERIES DRAWINGS FOR INTERIOR DESIGN AND FINISHES.

5. SEE 'AW' SERIES DRAWINGS FOR ARCHITECTURAL SIGNAGE.

6. SEE 'Q-' SERIES DRAWINGS FOR HOSPITAL EQUIPMENT AND FURNISHINGS.

7. NO DRILLING OR JACK HAMMERING ACTIVITIES ALLOWED DURING BUSINESS

HOURS.

1/4" = 1'-0" B7

OBSERVATION ROOM - B1C23

1/4" = 1'-0" C7

SOILED UTILITY - B1C53

1/4" = 1'-0"

C6

SOILED UTILITY - EAST ELEVATION

1/4" = 1'-0" C4

SOILED UTILITY - WEST ELEVATION

1/4" = 1'-0" D7

STAFF TOILET - BC51

1/4" = 1'-0"

D6

STAFF TOILET - NORTH ELEVATION

1/4" = 1'-0" D4

STAFF TOILET - EAST ELEVATION

1/4" = 1'-0"

D2

STAFF TOILET - WEST ELEVATION

FINISH ABBREVIATIONS

REFER TO SHEET IN601 FOR FINISH LEGEND

ABBREVIATION FINISH TYPE

AT ACOUSTICAL CEILING TILE

CC CUBICLE CURTAIN TRACK

CG CORNER GUARD

HR HAND RAIL

LVT LUXURY VINYL TILE

P PAINT

PL PLASTIC LAMINATE

PT PORCELAIN TILE

RB RESILIENT BASE

RWC RIGID WALL COVERING

S SOLID SURFACE

SS STAINLESS STEEL

TR TILE TRIM

WFT WALL FINISH TYPE

WG WALL GUARD

1/4" = 1'-0" F7

PAT TLT & SHWR - B1C25A/B1C25B

1/4" = 1'-0"

F4

PAT TLT & SHWR - EAST ELEVATION

1/4" = 1'-0" F2

PAT TLT & SHWR - SOUTH ELEVATION

1/4" = 1'-0"

F1

PAT TLT & SHWR - WEST ELEVATION

1/4" = 1'-0" F6

PAT TLT & SHWR - NORTH ELEVATION

KEYNOTES

JSN SCHEDULE

JSN NOMENCLATURE

FURNISHED BY /

INSTALLED BY

A1012 Telephone, Wall Mounted, 1 Line VV

A1067 Mirror, Float Glass, ADA Accessible CC

A1110 Headwall, Prefabricated, General, 1-2 bed CC

A1132 Rail, Accessory Mounting, Length As Required VC

A1165 Track, IV, Ceiling Mounted, 7 Foot CC

A1200 Lift System, Overhead, Patient Room VV

A4995 Table, Diaper Changing, Wall Mounted CC

A5030 Bench, Stall, Shower, Built In CC

A5075 Dispenser, Soap, Disposable VV

A5077 Dispenser, Hand Sanitizer, Hands-Free VV

A5082 Dispenser, Paper Towel, Sensor, Hands Free CC

A5090 Disposal, Sanitary Napkin, SS, Surface Mounted CC

A5107 Dispenser, Glove, Surgical/Examination, Wall Mntd VV

A5108 Waste Disposal Unit, Sharps VV

A5109 Grab Bar, 1-1/4" Dia., SS, 2 Wall, W/C Accessible CC

A5110 Grab Bar, 1-1/4" Dia., SS, 2 Wall, Shower Use CC

A5140 Hook, Garment, Security CC

A5180 Track, Cubicle, Surface Mounted CC

A5200 Dispenser, Toilet Tissue, SS, 2-Roll, Surface Mntd VV

CS200 Sink, SS, Single Compartment, 12x28x16 ID CC

CT050 Countertop, Stainless Steel CC

F0210M Chair, Side, Without Arms, VV

F0300 Chair, Task, Swivel, With Arms VV

F0500 Cart, Janitor's VV

F0505 Bucket, Mop, With Wringer, 26 Quart VV

F0725M Table, Occasional, Executive, Wood VV

F2000 Basket, Wastepaper, Fire Resistant VV

F2010 Basket, Wastepaper, Step-On VV

F2017M Waste Receptacle, 12 GAL CC

F2020 Can, Trash, 44 Gallon VV

F2540 Shredder, Paper, Security VV

M0013 Basket, Infectious Waste, Step-On VV

M1801 Computer, Microprocessing, w/Flat Panel Monitor VV

M1840 Printer/Copier/Fax Combination VV

M3070 Hamper, Linen, Mobile, w/Lid VV

M3072 Frame, Infectious Waste Bag w/Lid VV

M3150 Distribution System, Medication, Automatic VV

M3155 Cabinet, Inventory Management System VV

M4100 Sphygmomanometer, Aneroid, Wall Mounted VV

M4200 Otoscope/Ophthalmoscope, Wall Mounted VV

M4655 Stretcher, Mobile, CRS, 9 Position VV

M7040 Table, Overbed VV

M7415 Light, Exam, Wall Mounted CC

M7845 Monitor, Physiological, Bedside, 4 Channel VV

M8000 Shower Trolley System, Complete CC

P2000 Eyewash, Wall Mounted, Hands-Free CC

P2451 Valve, Mixing, Thermostatic, Eyewash CC

P3100 Lavatory, Vitreous China, Slab Type CC

P4700 Sink, Mop, Molded Stone CC

P6350 Sink, Flushing Rim, China CC

P8710 Utility Center, Plumbing Connection CC

P9050 Toilet, Wall Hung, Siphon Jet CC

U0001 Nurse Charting Station CC

1 EXTENT OF TILE; TILE BEHIND WALL MOUNTED FIXTURES

2 EXTENT OF SOLID SURFACE

3 ADA COMPLIANT P-TRAP COVER, REFER TO PLUMBING SHEETS

FOR ADDITIONAL INFORMATION

4 EQUIPMENT MOUNTED TO RAIL ABOVE WALL GUARDS

5 NEW MIXING VALVE IN ACCESSIBLE, STAINLESS STEEL, SURFACE

MOUNTED CABINET, HINGED DOOR WITH LOCK

6 SHOWER FLOOR TO SLOPE TO TRENCH DRAIN, SLOPE=.25/12;

REFER TO PLUMBING FOR MORE INFORMATION

7 PATIENT LIFT, SEE RCP FOR MORE INFORMATION

PARTITION RATING GRAPHICS:

4 HR FIRE BARRIER

3 HR FIRE BARRIER

2 HR FIRE & SMOKE BARRIER

2 HR FIRE BARRIER

2 HR FIRE BARRIER/SHAFT

1 HR FIRE & SMOKE BARRIER

1 HR FIRE BARRIER

1 HR FIRE BARRIER/SHAFT

SMOKE PARTITION (NON RATED)

NON RATED

PARTITION RATING GRAPHIC DESIGNATION: PRIORITY

1 HIGHEST

5 LOWEST

PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH

FIRE AND SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH

HATCH PATTERNS.

NOTE:

1. JSN NUMBERS THAT END WITH AN "M" SUFFIX INDICATE THAT THE ITEM IS A

MODIFIED VERSION OF THE VA'S EQUIPMENT LIST

2. JSN NUMBERS THAT START WITH A "U" PREFIX…