BUS
B U S
N O R T H
F R E S N O
S T R E E T
EAST HARVARD AVENUE
EAST CLINTON AVENUE
G E N E R A
TO
R
G E N E R A
TO
R
G E N E R A
TO
R
G E N E R A
TO
R
G E N E R A
TO
R
MAIN
ENTRANCE
SIGN
V A
M O N U M E N T
S
IG
N
FUEL TANK
#2
FUEL TANK
#1
TANK
O2
TANK
O2
TEL
XFMR
XFMR
XFMR XFMR
XFMR
MSS
SDCO
SDCO
SDCO
SDCO
SDCO
DY
H
DY
H
DY
H
DY
H
D Y
H
C D
F
C
D
F
CD
F
WV
W V
W V
SSCO
SSCO
PIV
W V
WV
W V
W V
W V
W V
WV
SDCO
SIGN
E
E
E
2"
FW
SS
SOLAR PANELS
SOLAR PANELS
SSCO
E
E
E E
E
H
H H H
H
HH
H H H H H
HHHH
H
H
E
E
E
T
E
T
S
EX. SEWER
EX. S.D.
EX. IRR.
EX. ELEC.
EX. UTILITY TUNNEL
EX. S.D.
EX. ELEC.
E X
. E L E
C
E X
. IR
R
EX. STLT.
EX. COMM
OPC
PROJECT LOCATION IN
BASEMENT BELOW
E X
W
A T
E R
F
IR
E
BUILDING 1
MAIN HOSPITAL
BUILDING 32
WAREHOUSE
BUILDING 19
SWITCH GEAR
BUILDING 34
MENTAL HEALTH/ PHYSICAL REHAB
BUILDING 24
MEDICAL EDUCATION
AND LIBRARY
BUILDING 3
ENGINEERIN SHOPS
B U
IL
D
IN
G
L
IQ
U
ID
O X
Y G
E N
S T
O R
A G
E
H Y
D R
O N
IC
S
S U
P P
O R
T F
A C
IL
IT
Y
E X
IS
T
IN
G
P A
R K
IN
G
L O
T N
O T
I N
U S
E
20 23 37
EX. S.D.
D8
CS101
C8
CS101
E5
CS101 EXISTING
MODULAR
BUILDING TO
REMAIN
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE INSTALLATION OF
ALL WORK RELATED TO MECHANICAL UTILITIES AS SHOWN ON THIS PLAN
INCLUDING: TRENCHING, BACKFILL, SUPPORTS, CLEANOUT PADS, SERVICE STOPS
AND BOXES, SERVICE LINES, TESTING, CLEANING, AND STERILIZING. ANY WORK NOT
ACCEPTED BY THE ARCHITECT OR ENGINEER DUE TO IMPROPER WORKMANSHIP OR
LACK OF PROPER COORDINATION SHALL BE REMOVED AND CORRECTLY INSTALLED
AT THE CONTRACTOR'S EXPENSE, AS DIRECTED.
2. MINIMUM DEPTHS OF COVER SHALL BE: 36" FOR WATERLINES AND 48" FOR
SEWER, EXCEPT AT BUILDING CONNECTION.
3. ALL WORK DETAILED ON THESE PLANS TO BE PERFORMED UNDER CONTRACT
SHALL, EXCEPT AS OTHERWISE STATED OR PROVIDED OF HEREON, BE
CONSTRUCTED IN ACCORDANCE WITH THE IAPMO UNIFORM PLUMBING CODE &
NFPA 24, LATEST EDITION.
4. UTILITY LINES SHALL BE INSTALLED PRIOR TO PAVEMENT, CURB AND GUTTER,
AND/OR SIDEWALK, AS APPLICABLE.
5. ROUGH GRADING OF SITE (+/- 0.5') SHALL BE COMPLETED PRIOR TO INSTALLATION
OF UTILITY LINES.
6. CONTRACTOR WILL BE RESPONSIBLE FOR CONNECTIONS TO BUILDING DRAIN
LINES AND ALL NECESSARY FITTINGS.
7. ALL VALVES SHALL BE ANCHORED PER COS STANDARD DWG. 2333.
8. FIRE LINES SHALL USE PIPE MATERIALS UNDERWRITERS LABORATORIES LISTED
AND APPROVED FOR FIRE SERVICE.
9. UTILITY LOCATIONS DETERMINED FROM VA MASTER UTILITY PLAN. CONTRACTOR
SHALL VERIFY INVERTS AND LOCATIONS OF EXISTING UTILITY LINES PRIOR TO
BEGINNING OF WORK. ALL CONFLICTS SHALL BE BROUGHT TO ATTENTION OF THE
ENGINEER AND RESOLVED PRIOR TO BEGINNING OF WORK.
10. CONTRACTOR SHALL NOTIFY THE AUTHORITY HAVING JURISDICTION PRIOR TO
INSTALLATION OF FIRE SERVICE LINES, AND PRIOR TO TESTING OF ALL WATERLINES.
CONTRACTOR SHALL COMPLETE, SIGN, AND SUBMIT THE "CONTRACTOR'S MATERIAL
& TEST CERTIFICATE FOR UNDERGROUND PIPING" IN ACCORDANCE WITH NFPA 24.
UTILITY NOTES
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Mechanical, Electrical and Plumbing:
B
IM
/5
-1
-2
E x p a n d
E D
B e d s
/5
-1
-2
.S
IT
E .r v t
/1
/2
:5
:5
A
M
CD101
CIVIL DEMO PLAN
TRIPLE C - THE A-E GROUP
4401 Atlantic Avenue, Suite 200
Long Beach, CA 90807
562.452.7175
MAT PERKINS
REMODEL ED BEDS FOR
OBSERVATION BEDS
2615 E. CLINTON AVE., FRESNO, CA 93703
570-17-210
OPC
06/18/2021 M. PERKINS K.
STRUBLE
100% FINAL
DOCUMENTS
1" = 30'-0" F1
CIVIL DEMO PLAN - DEDUCT ALTERNATE NO. 3
KEYNOTES
1 INSTALL PARKING BARRIER - 6' CLEAR OPENING MAX.
2 EXISTING PARKING BARRIER
3 RELOCATE EXISTING PARKING BARRIER - 6' CLEAR OPENING MAX.
4 EXISTING ELEVATOR
5 PROPOSED TEMPORARY ELEVATOR- REMOVE ASPHALT, CURB & GUTTER. CONSTRUCT 4' DEEP "PIT"
FOR ELEVATIOR. CURB & GUTTER, ASPHALT TO BE REPLACED UPON REMOVAL OF TEMPORARY
ELEVATOR - SEE ELECTRICAL PLANS FOR ELECTRICAL REMOVAL UPON COMPLETION FOR PROJECT
6 TEMPORARY 9,500 SF MODULAR EMERGENCY DEPARTMENT - SEE SHEET A-100M , DEDUCT ALTERNATE
NO. 3
7 MOBILE CT & X-RAY TRAILER
8 CONSTRUCT TEMPORARY "AMBULANCE PARKING ONLY" SIGN
9 CONSTRUCT TEMPORARY "VA POLICE PARKING ONLY" SIGN
10 CONSTRUCT TEMPORARY "EMERGENCY PATIENT PARKING - 10 MINUTES" SIGN
11 EXISTING CONSTRUCTION TRAILER TO BE RELOCATED PRIOR T PROJECT START. COORDINATE WITH
COR.
13 EXISTING TREE, PORTION OF WALL AND RAILING TO BE REMOVED - WALL AND RAILING TO BE REPLACED
UPON REMOVAL OF TEMPORARY ELEVATOR
14 CONSTRUCT TEMPORARY 4" DIP FIRE LINE BELOW GRADE 36" MIN. - TEE CONNECT AT EXISTING
MODULAR. INSTALL FIRE RISER, SEE SHEET CS501 FOR ADDITIONAL INFORMATION.
15 CONSTRUCT TEMPORARY 2" PVC COMMUNICATION CONDUIT BELOW GRADE 24" MIN. TO EXISTING
MODULAR
16 TEMPORARY FENCED MECHANICAL YARD W/ TEMPORARY AIR HANDLING UNIT - SEE MECHANICAL SITE
PLAN FOR ADDITIONAL INFORMATION
17 FENCED CONTRACTOR STORAGE YARD 2,200 SF
18 INSTALL 10' CLEAR PREFABRICATED TEMPORARY CANOPY, TO BE REMOVED AFTER CONSTRUCTION IS
COMPLETE
19 PROVIDE NEW FIBER FROM EXISTING RACK IN EXISTING MODULAR TO NEW MODULAR RACK
COORDINATE ROUTING WITH MODULAR MANUFACTURER
20 EXISTING ELEC. MANHOLE / PULLBOX TO REMAIN, PROTECT IN PLACE
21 CONSTRUCT TEMPORARY "EMERGENCY ROOM ACCESS" SIGN
22 CONSTRUCT CONSTRUCTION AND SAFETY SIGN SEE DETAIL F8 , SHEET CS501
23 EXISTING AREAWAY
24 CONSTRUCT CHASE - SEE ARCHITECTURAL PLANS, COORDINATE SIDEWALK AND ROADWAY CLOSURES
WITH COR - EAST BOUND LANE TO REMAIN OPEN AT ALL TIMES
25 EX. BUS STOP
26 CONSTRUCT TEMPORARY FENCING AROUND GRATE OPENING
27 CONSTRUCT TEMPORARY STAIRS AND ADA ACCESSIBLE RAMP - SEE ARCH. MODULAR BUILDING SHEET A-100M
28 CONSTRUCT TEMPORARY STAIRS - SEE ARCH. MODULAR BUILDING SHEET A-100M
30 EXISTING PARKING BARRIER TO BE REMOVED/RELOCATED
31 RE-STRIPE PARKING LOT FOR 90 DEGREE STALLS ON WEST SIDE, NO PARKING ON EAST
33 EXISTING STORAGE CONTAINER/AREA TO BE REMOVED/RELOCATED
34 CONSTRUCT TEMPORARY ELECTRICAL CONDUIT CONNECT TO NEW TRANSFORMER, SEE ELETRICL
PLAN - TRENCH 2' BELOW GRADE - SEE DETAIL C1 SHEET CS501
35 CONSTRUCT TEMPORARY 4" SEWER LATERAL ABOVE GRADE- CONNECT TO EXISTING MANHOLE
THROUGH TOP
36 EXISTING STREETLIGHT POLE TO BE REMOVED/STORED FOR RE-INSTALL UPON REMOVAL OF MODULAR
BUILDING. PEDESTAL TO REMAIN. COORDINATE WITH COR.
37 EXISTING TREE TO BE REMOVED
38 CONSTRUCT ELECTRICAL TRANSFORMER SEE ELECTRICAL PLANS ON JENSEN PRECAST CONCRETE
TRANSFORMER PAD DETAIL B9, SHEET CS502
39 CONSTRUCT TEMPORARY ELECTRICAL CONDUIT CONNECT MEDIUM VOLTAGE WITHIN EXISTING
MAHNOLE - SEE ELECTRICAL PLANS
40 CONSTRUCT TEMPORARY WATER CONNECTION - CONSTRUCT 1/2" COPPER PIPE BELOW GRADE 36"
MIN., TEE CONNECT TO EXISTING COPPER PIPE UNDER EXISTING MODULAR BUILDING
41 CONSTRUCT GENERATOR AND CONDUIT, CONNECT TO NEW MODULAR BUILDING - SEE ELECTRICAL
PLANS
Revisions: Date:
NOTE: NOT ALL KEYNOTES USED THIS SHEET
LIMITS OF CONSTRUCTION
N O R T H
F R E S N O
S T R E E T
EAST HARVARD AVENUE
EAST CLINTON AVENUE
SIGN
E
E
E
2"
FW
SS
MOTORCYCLES PARKING LOT
APARKING LOT
B
P
AR
K
IN
G
LO
T C
PARKING LOT
PARKING LOT
D
BUILDING 1
MAIN HOSPITAL
BUILDING OP
OUTPATIENT CLINIC
BUILDING 32
WAREHOUSE
BUILDING 34
MENTAL HEALTH / PHYSICAL REHAB
BUILDING 3
ENGINEERING SHOPS
BUILDING 24
MEDICAL EDUCATION
AND LIBRARY
BUILDING 19
SWITCH GEAR
B U
IL
D
IN
G
LI
Q U
ID
O X
YG
E N
S
TO
R
AG
E
SOLAR PANELS
SOLAR PANELS
H
YD
R O N
IC
S
S U P P O R T
FA
C
IL
IT
Y
SOLAR PANELS
SOLAR PANELS
SSCO
E
E
E E
E
H
H H H
H
HH
H H H H H
HHHH
H
H
E
E
T
E
T
S
EX. SEWER
EX. S.D.
EX. IRR.
EX. ELEC.
EX. UTILITY TUNNEL
EX. S.D.
EX. ELEC.
E X
. E L E
C
E X
. IR
R
EX. STLT.
STAFF
ENTRANCE
EX. COMM
OPC
PROJECT LOCATION IN
BASEMENT BELOW
E X
W
A T
E R
F
IR
E
BUILDING 1
MAIN HOSPITAL
BUILDING 32
WAREHOUSE
BUILDING 19
SWITCH GEAR
BUILDING 34
MENTAL HEALTH/ PHYSICAL REHAB
BUILDING 24
MEDICAL EDUCATION
AND LIBRARY
BUILDING 3
ENGINEERIN SHOPS
B U
IL
D
IN
G
L
IQ
U
ID
O X
Y G
E N
S T
O R
A G
E
H Y
D R
O N
IC
S
S U
P P
O R
T F
A C
IL
IT
Y
E X
IS
T
IN
G
P A
R K
IN
G
L O
T N
O T
I N
U S
E
56'-0"
'-0
EX. S.D.
D8
CS101
C8
CS101
AMBULANCE /
EMERGENCY
ENTRANCE
PATIENT / PUBLIC
ENTRANCE
E5
CS101
FLOORING IN TRAILER WILL BE CHANGED TO
RENTAL BUDGET QUALITY . CONTRACTOR TO
RE-SELECT FLOORING CURRENTLY SPECIFIED IN
DESIGN DRAWINGS TO LOWER PRICE POINT.
TEMP MODULAR REQUIRES THREE EXAM ROOMS
TO BE NEGATIVE PRESSURE.
AMBULANCE REQUIRED TO BACK IN
FOR PATIENT DROP-OFF
EXISTING
MODULAR
BUILDING TO
REMAIN
10'-0"
'-0
5' -0
ACCESS LEGEND
16 Exam Rooms 4 Procedure Rooms 4 Physician Office 1 Business Office 1 Break Room 4 Restroom 1 Waiting Area 1 Nurses Station 2 Labs 1 Records Room 1 Clean Linens Room 1 Soiled Linens Room 1 Utility Closet
CONNECT TO EXISTING UTILITIES SUPPLIED TO PREVIOUS TEMPORARY BUILDING-
CONTRACTOR TO FIELD VERIFY, ELECTRICAL, COMM, WATER, SEWER - SEE
MODULAR BUILDING PLANS A-100-1
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE INSTALLATION OF
ALL WORK RELATED TO MECHANICAL UTILITIES AS SHOWN ON THIS PLAN
INCLUDING: TRENCHING, BACKFILL, SUPPORTS, CLEANOUT PADS, SERVICE STOPS
AND BOXES, SERVICE LINES, TESTING, CLEANING, AND STERILIZING. ANY WORK NOT
ACCEPTED BY THE ARCHITECT OR ENGINEER DUE TO IMPROPER WORKMANSHIP OR
LACK OF PROPER COORDINATION SHALL BE REMOVED AND CORRECTLY INSTALLED
AT THE CONTRACTOR'S EXPENSE, AS DIRECTED.
2. MINIMUM DEPTHS OF COVER SHALL BE: 36" FOR WATERLINES AND 48" FOR
SEWER, EXCEPT AT BUILDING CONNECTION.
3. ALL WORK DETAILED ON THESE PLANS TO BE PERFORMED UNDER CONTRACT
SHALL, EXCEPT AS OTHERWISE STATED OR PROVIDED OF HEREON, BE
CONSTRUCTED IN ACCORDANCE WITH THE IAPMO UNIFORM PLUMBING CODE &
NFPA 24, LATEST EDITION.
4. UTILITY LINES SHALL BE INSTALLED PRIOR TO PAVEMENT, CURB AND GUTTER,
AND/OR SIDEWALK, AS APPLICABLE.
5. ROUGH GRADING OF SITE (+/- 0.5') SHALL BE COMPLETED PRIOR TO INSTALLATION
OF UTILITY LINES.
6. CONTRACTOR WILL BE RESPONSIBLE FOR CONNECTIONS TO BUILDING DRAIN
LINES AND ALL NECESSARY FITTINGS.
7. ALL VALVES SHALL BE ANCHORED PER COS STANDARD DWG. 2333.
8. FIRE LINES SHALL USE PIPE MATERIALS UNDERWRITERS LABORATORIES LISTED
AND APPROVED FOR FIRE SERVICE.
9. UTILITY LOCATIONS DETERMINED FROM VA MASTER UTILITY PLAN. CONTRACTOR
SHALL VERIFY INVERTS AND LOCATIONS OF EXISTING UTILITY LINES PRIOR TO
BEGINNING OF WORK. ALL CONFLICTS SHALL BE BROUGHT TO ATTENTION OF THE
ENGINEER AND RESOLVED PRIOR TO BEGINNING OF WORK.
10. CONTRACTOR SHALL NOTIFY THE AUTHORITY HAVING JURISDICTION PRIOR TO
INSTALLATION OF FIRE SERVICE LINES, AND PRIOR TO TESTING OF ALL WATERLINES.
CONTRACTOR SHALL COMPLETE, SIGN, AND SUBMIT THE "CONTRACTOR'S MATERIAL
& TEST CERTIFICATE FOR UNDERGROUND PIPING" IN ACCORDANCE WITH NFPA 24.
MODULAR BUILDING DATA
UTILITY NOTES
VEHICLE PATH
PEDESTRIAN PATH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Mechanical, Electrical and Plumbing:
B
IM
/5
-1
-2
E x p a n d
E D
B e d s
/5
-1
-2
.S
IT
E .r v t
/1
/2
:5
:5
A
M
CS101
CIVIL SITE PLAN
TRIPLE C - THE A-E GROUP
4401 Atlantic Avenue, Suite 200
Long Beach, CA 90807
562.452.7175
MAT PERKINS
REMODEL ED BEDS FOR
OBSERVATION BEDS
2615 E. CLINTON AVE., FRESNO, CA 93703
570-17-210
OPC
06/18/2021 M. PERKINS K.
STRUBLE
100% FINAL
DOCUMENTS
1" = 30'-0" F1
SITE PLAN - DEDUCT ALTERNATE NO. 3
KEYNOTES
1 INSTALL PARKING BARRIER - 6' CLEAR OPENING MAX.
2 EXISTING PARKING BARRIER
3 RELOCATE EXISTING PARKING BARRIER - 6' CLEAR OPENING MAX.
4 EXISTING ELEVATOR
5 PROPOSED TEMPORARY ELEVATOR- REMOVE ASPHALT, CURB & GUTTER. CONSTRUCT 4' DEEP "PIT"
FOR ELEVATIOR. CURB & GUTTER, ASPHALT TO BE REPLACED UPON REMOVAL OF TEMPORARY
ELEVATOR - SEE ELECTRICAL PLANS FOR ELECTRICAL REMOVAL UPON COMPLETION FOR PROJECT
6 TEMPORARY 9,500 SF MODULAR EMERGENCY DEPARTMENT - SEE SHEET A-100M , DEDUCT ALTERNATE
NO. 3
7 MOBILE CT & X-RAY TRAILER
8 CONSTRUCT TEMPORARY "AMBULANCE PARKING ONLY" SIGN
9 CONSTRUCT TEMPORARY "VA POLICE PARKING ONLY" SIGN
10 CONSTRUCT TEMPORARY "EMERGENCY PATIENT PARKING - 10 MINUTES" SIGN
11 EXISTING CONSTRUCTION TRAILER TO BE RELOCATED PRIOR T PROJECT START. COORDINATE WITH
COR.
13 EXISTING TREE, PORTION OF WALL AND RAILING TO BE REMOVED - WALL AND RAILING TO BE REPLACED
UPON REMOVAL OF TEMPORARY ELEVATOR
14 CONSTRUCT TEMPORARY 4" DIP FIRE LINE BELOW GRADE 36" MIN. - TEE CONNECT AT EXISTING
MODULAR. INSTALL FIRE RISER, SEE SHEET CS501 FOR ADDITIONAL INFORMATION.
15 CONSTRUCT TEMPORARY 2" PVC COMMUNICATION CONDUIT BELOW GRADE 24" MIN. TO EXISTING
MODULAR
16 TEMPORARY FENCED MECHANICAL YARD W/ TEMPORARY AIR HANDLING UNIT - SEE MECHANICAL SITE
PLAN FOR ADDITIONAL INFORMATION
17 FENCED CONTRACTOR STORAGE YARD 2,200 SF
18 INSTALL 10' CLEAR PREFABRICATED TEMPORARY CANOPY, TO BE REMOVED AFTER CONSTRUCTION IS
COMPLETE
19 PROVIDE NEW FIBER FROM EXISTING RACK IN EXISTING MODULAR TO NEW MODULAR RACK
COORDINATE ROUTING WITH MODULAR MANUFACTURER
20 EXISTING ELEC. MANHOLE / PULLBOX TO REMAIN, PROTECT IN PLACE
21 CONSTRUCT TEMPORARY "EMERGENCY ROOM ACCESS" SIGN
22 CONSTRUCT CONSTRUCTION AND SAFETY SIGN SEE DETAIL F8 , SHEET CS501
23 EXISTING AREAWAY
24 CONSTRUCT CHASE - SEE ARCHITECTURAL PLANS, COORDINATE SIDEWALK AND ROADWAY CLOSURES
WITH COR - EAST BOUND LANE TO REMAIN OPEN AT ALL TIMES
25 EX. BUS STOP
26 CONSTRUCT TEMPORARY FENCING AROUND GRATE OPENING
27 CONSTRUCT TEMPORARY STAIRS AND ADA ACCESSIBLE RAMP - SEE ARCH. MODULAR BUILDING SHEET A-100M
28 CONSTRUCT TEMPORARY STAIRS - SEE ARCH. MODULAR BUILDING SHEET A-100M
30 EXISTING PARKING BARRIER TO BE REMOVED/RELOCATED
31 RE-STRIPE PARKING LOT FOR 90 DEGREE STALLS ON WEST SIDE, NO PARKING ON EAST
33 EXISTING STORAGE CONTAINER/AREA TO BE REMOVED/RELOCATED
34 CONSTRUCT TEMPORARY ELECTRICAL CONDUIT CONNECT TO NEW TRANSFORMER, SEE ELETRICL
PLAN - TRENCH 2' BELOW GRADE - SEE DETAIL C1 SHEET CS501
35 CONSTRUCT TEMPORARY 4" SEWER LATERAL ABOVE GRADE- CONNECT TO EXISTING MANHOLE
THROUGH TOP
36 EXISTING STREETLIGHT POLE TO BE REMOVED/STORED FOR RE-INSTALL UPON REMOVAL OF MODULAR
BUILDING. PEDESTAL TO REMAIN. COORDINATE WITH COR.
37 EXISTING TREE TO BE REMOVED
38 CONSTRUCT ELECTRICAL TRANSFORMER SEE ELECTRICAL PLANS ON JENSEN PRECAST CONCRETE
TRANSFORMER PAD DETAIL B9, SHEET CS502
39 CONSTRUCT TEMPORARY ELECTRICAL CONDUIT CONNECT MEDIUM VOLTAGE WITHIN EXISTING
MAHNOLE - SEE ELECTRICAL PLANS
40 CONSTRUCT TEMPORARY WATER CONNECTION - CONSTRUCT 1/2" COPPER PIPE BELOW GRADE 36"
MIN., TEE CONNECT TO EXISTING COPPER PIPE UNDER EXISTING MODULAR BUILDING
41 CONSTRUCT GENERATOR AND CONDUIT, CONNECT TO NEW MODULAR BUILDING - SEE ELECTRICAL
PLANS
LIMITS OF CONSTRUCTION
NTS
C8
PARKING LOT FACING E.R.
NTS
D8
E.R. FACING PARKING LOT
NTS
E5
PARKING LOT FACING EAST
LIMITS OF
CONSTRUCTION
PORTION OF
RAILING TO BE
REMOVED. WALL
TO REMAIN
P E
D E
S T
R
IA
N A
C C
E S
S T
O R
E M
A
IN
UP
TREE TO BE
REMOVED
PROVIDE
CONTINUOUS
ACCESS DURING
CONSTRUCTION
EXISTING STREETLIGHT
POLE TO BE REMOVED.
PEDESTAL TO REMAIN
Revisions: Date:
NOTE: NOT ALL KEYNOTES USED THIS SHEET
FOR TRENCH WIDTHS EXCEEDING 4' [1219mm] REFER TO VA
STANDARD DETAIL 32 12 16-02 "TYPE 2 UTILITY TRENCH PATCH".
FOR TRENCH WHERE PORTLAND CEMENT CONCRETE (PCC)
PAVEMENT EXISTS, REFER TO 32 12 16-03 "TYPE 3 UTILITY
TRENCH PATCH".
2" [50mm] MINIMUM OR THICKNESS OF EXISTING PAVEMENT
WHICHEVER IS GREATER.
BITUMINOUS SURFACE TREATMENT (CHIPSEAL) REQUIRED ONLY FOR
LONGITUDINAL TRENCHES WITH WIDTHS GREATER THAN 6'
[1829mm].
4" [100mm] MINIMUM ABC OR THICKNESS OF EXISTING GRANULAR
BASE COURSE MATERIALS (E.G. ABC & SELECT MATERIAL)
WHICHEVER IS GREATER.
REFER TO VA STANDARD DETAIL 32 12 16-04 "UTILITY TRENCH
PAVEMENT PATCH NOTES" (RIGHT) FOR ADDITIONAL INFORMATION.
SAW CUT EXISTING.
ASPHALT FULL
DEPTH BOTH SIDESTACK COAT
(TYP.)
EXISTING
PAVEMENT
4'-0" MAX.
[1219mm]
1'-0" MAX.
[305mm]
1'-0" MAX.
[305mm]
TRENCH
BACKFILL
ABC 100%
MIN.
COMPACTION
ASPHALTIC CONCRETE
GENERAL NOTES
1. MATERIAL AND COMPACTION REQUIREMENTS FOR PIPE BEDDING/SHADING SHALL BE IN
ACCORDANCE WITH THE SPECIFICATIONS FOR THE APPLICABLE UTILITY
PIPE.
2. TRENCH BACKFILL SHALL COMMENCE 1 FOOT [305mm] ABOVE THE TOP OF PIPE AND
SHALL BE PER SECTION 31 20 11
3. BACKFILL COMPACTION REQUIREMENTS SHALL BE PER SECTION 31 20 11
4. THE 1 FOOT [305mm] TRENCH "SHOULDER" AREAS SHALL BE DELETED FOR TYPE 2
TRENCHES.
5. ABC SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION 32 12 16
6.
7.
ASPHALTIC TACK MATERIAL SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF
SECTION
32 12 16
8.
ASPHALTIC CONCRETE SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF
SECTION 32 12 16 FOR THE TYPE SPECIFIED.
BITUMINOUS SURFACE TREATMENT (CHIP SEAL) SHALL BE IN ACCORDANCE WITH THE
REQUIREMENTS OF SECTION 32 12 16 FOR THE TYPE SPECIFIED.
VA OFFICE OF CONSTRUCTION & FACILITIES MANAGEMENT
U.S. Department of Veterans Affairs
TRIPLE C - THE A/E GROUP, LLC(GENERAL CONTRACTOR)
REMODEL ED BEDS FOR OBSERVATION BEDS
PROJ. NO. 570-17-210
CL
PROJECT RENDERING
SITE CONSTRUCTION
SIGN
PLAN VIEW
2" x 4" FRAMING
4" x 6"POSTS
FACE
SITE SAFETY PLAN VIEW
2" x 4" FRAMING
4" x 6"POSTS
FACE
U.S. Department of Veterans Affairs
THIS PROJECT HAS WORKED
CL
000 DAYS
WITHOUT A LOST TIME ACCIDENT
THE LIFE YOU SAVE MAY BE YOUR OWN
GENERAL CONTRACTORS FIRM NAME
ZERO IN
ON
SAFETY
ALL VISIBLE SURFACES TO
BE
PRIMED AND PAINTED
SIGN ATTACHED TOGETHER
WITH
WOOD SCREW & LAG BOLTS
CHANGEABLE NUMBERS
FACE PANEL TO BE AN EXTERIOR GRADE.
MDO
SHEERT OR AN ALUMINU M SKIN LAMINATED
TO
A WOOD OR PLASTIC CORE IS PREFERRED
WITH EDGES PHYSICALLY SEALED.
4" x 4" POSTS
DEPTH & TYPE OF
FOOTING
DETERMINED BY EXISTING
SOIL CONDITIONS.
DEPTH & TYPE OF
FOOTING
DETERMINED BY EXISTING
SOIL CONDITIONS.
8'
1' 3'
1'
3'
8'
1 7/8" 3'-8 1/8" 2" 2"
3'-7 7/8" 2 1/8"
4'
8'
4"
4"
3' 3'
"1
4'
APPLICABLE NOTES FROM THE CURRENT IN-PLACE REQUIREMENTS FOR DEPARTMENT OF
VETERANS AFFAIRS FACILITIES:
"SITE DEVELOPMENT DESIGN MANUAL - FEBRUARY 2013"
5.2 GENERAL UTILITY DESIGN REQUIREMENTS
5.2.1 CLEARANCES AND CROSSINGS
THE A/E SHALL DESIGN THE SITE WITH THE FEWEST CROSSINGS OF UTILITIES POSSIBLE. THE
A/E SHALL CONSIDER THE FOLLOWING ORDER OF PRIORITY FOR UNDERGROUND FACILITIES:
● SANITARY SEWER
● STORM SEWER
● WATER MAIN
● OTHER UTILITIES
5.2.6 MINIMUM DEPTH OF COVER
INDICATE BY NOTES ON DRAWINGS OR DETAIL SECTION, THE MINIMUM DEPTH OF COVER
REQUIRED OVER EACH SPECIFIC UTILITY SYSTEM. ALL BURIED UTILITIES SHALL HAVE
UNDERGROUND DETECTABLE WARNING TAPE INSTALLED IN THE TRENCH.
● MINIMUM COVER FOR STORM SEWER LINES SHALL BE AT LEAST 2’-0” (600 MM) FROM FINISH
GRADES.
● TOP OF POTABLE WATER, CHILLED WATER, FUEL AND APPURTENANCES SHALL BE AT
LEAST 1’-0” (300 MM) BELOW FROST PENETRATION.
● THE MINIMUM DEPTH OF SANITARY SEWER LINES AT THE TERMINUS POINT SHALL BE 4’-0”
(1200MM). WHERE
PRACTICAL, TOP OF SEWERS SHALL BE AT LEAST 1’-0” (300 MM) BELOW FROST PENETRATION.
WHERE SUCH DEPTH BELOW IS NOT PRACTICAL, PROVIDE FREEZE PROTECTION AND/OR
SUPPORTING FOUNDATIONS TO A DEPTH BELOW THE FROST LINE AND SECURELY FASTEN
SEWER TO FOUNDATION.
5.2.7 UTILITIES DISTRIBUTION TYPE
THE UTILITY DISTRIBUTION TYPE SHALL BE DETERMINED ON A PROJECT BY PROJECT BASIS.
THE A/E MUST CONSIDER THE
EXISTING SITE CONDITIONS AND BUDGET WHEN DECIDING WHAT TYPE TO USE.
5.2.7.1 TRENCHES: GENERALLY, DO NOT INSTALL MORE THAN ONE UTILITY SYSTEM IN THE
SAME TRENCH. HOWEVER, DUE TO
SITE CONSTRAINTS AND VALUE ENGINEERING CONCEPTS, MULTIPLE UTILITIES IN THE SAME
TRENCH WILL BE EVALUATED BY THE
GOVERNMENT ON A PER CASE BASIS. PRIOR TO APPROVING ANY MULTIPLE LINE TRENCH,
THE A/E SHALL DOCUMENT THAT THE USE OF THE MULTIPLE LINE TRENCH WILL NOT
NEGATIVELY IMPACT THE UTILITY SYSTEM, ADEQUATE CLEARANCES ARE PROVIDED FOR THE
OPERATION AND MAINTENANCE OF THE SYSTEMS, AND THAT THE JOINT TRENCH WILL NOT
POSE ANY CONTRACTIBILITY CONSTRAINTS. THERE MUST BE A MINIMUM OF 12” (300 MM)
BETWEEN THE OUTSIDE DIAMETERS OF ALL PIPES TO OBTAIN THE REQUIRED COMPACTION.
5.2.8 HORIZONTAL CLEARANCE
THE HORIZONTAL CLEARANCE SHALL BE MEASURED BETWEEN THE OUTSIDE DIMENSION OF
THE PIPE, DUCT BANK, OR STRUCTURE.
5.2.8.1 WATER AND SANITARY SEWER:
MAINTAIN A HORIZONTAL CLEARANCE BETWEEN POTABLE WATER MAINS AND GRAVITY FLOW
SANITARY SEWER/SANITARY SEWER FORCE MAINS OF AT LEAST 10 FEET (3M). THE
HORIZONTAL CLEARANCE BETWEEN POTABLE WATER MAINS AND SANITARY SEWER MAINS
MAY BE REDUCED TO 6’-0” (1800 MM) WHEN: LOCAL CONDITIONS PREVENT A HORIZONTAL
CLEARANCE OF 10’-0” (3 M), THE WATER MAIN INVERT IS A MINIMUM OF 18” (450 MM) ABOVE
THE CROWN OF THE SEWER, AND THE WATER MAIN IS IN A TRENCH, SEPARATED BY
UNDISTURBED SOIL. WHEN THE SPECIFIED HORIZONTAL CLEARANCE CANNOT BE MET, THE
WATER MAIN SHALL BE CONSTRUCTED WITH MECHANICAL JOINT DUCTILE IRON PIPE PER
SPECIFICATION 33 10 00 – WATER UTILITIES, AND THE SANITARY SEWER SHALL BE
CONSTRUCTED WITH MECHANICAL JOINT PRESSURE RATED DUCTILE IRON PIPE PER
SPECIFICATION 33 30 00 – SANITARY SEWAGE UTILITIES. HORIZONTAL CLEARANCES SHALL
COMPLY WITH THE REQUIREMENTS OF THE STATE HEALTH DEPARTMENT, DEPARTMENT OF
ENVIRONMENTAL QUALITY, OR AGENCY GOVERNING THE FACILITY OF POTABLE WATER MAINS
AND SYSTEMS.
5.2.8.2 WATER AND CHILLED WATER:
MAINTAIN A HORIZONTAL CLEARANCE OF AT LEAST 6’-0” (1800MM) BETWEEN POTABLE WATER
MAINS AND RECLAIMED/REUSE AND CHILLED WATER MAINS.
5.2.8.3 WATER AND STORM SEWER:
MAINTAIN A HORIZONTAL CLEARANCE OF AT LEAST 5’-0” (1500MM) BETWEEN POTABLE WATER
MAINS AND STORM SEWERS.
5.2.8.4 DUCT BANKS AND PIPED UTILITIES:
MAINTAIN A HORIZONTAL CLEARANCE OF AT LEAST 3’-0” (900 MM) BETWEEN DUCT BANKS AND
PIPED UTILITIES.
5.2.9 VERTICAL CLEARANCE
THE VERTICAL CLEARANCE SHALL BE MEASURED BETWEEN THE OUTSIDE DIMENSION OF THE
PIPE, DUCT BANK, OR STRUCTURE. FOR INSULATED PIPING, THE CLEARANCE SHALL BE
MEASURED TO THE OUTSIDE OF THE INSULATION. AT UTILITY CROSSINGS WHERE ADEQUATE
COMPACTION OF THE BEDDING MATERIAL CANNOT BE OBTAINED, USE FLOWABLE FILL IN THE
ZONES WERE COMPACTION IS IMPOSSIBLE OR IMPRACTICAL.
● MAINTAIN A MINIMUM VERTICAL CLEARANCE OF AT LEAST 1’-0” (300 MM) BETWEEN ALL
UTILITIES AT CROSSINGS UNLESS
OTHERWISE SPECIFIED BELOW.
● AT CROSSINGS OF POTABLE WATER MAINS AND SANITARY SEWERS, STORM SEWERS,
FORCE MAINS, RECLAIMED/REUSE
MAINS, OR CHILLED WATER MAINS, WHERE THE POTABLE WATER MAIN CROSSES ABOVE THE
OTHER UTILITY, THE MINIMUM
VERTICAL SEPARATION SHALL BE 18” (450 MM), OR AS REQUIRED BY THE STATE HEALTH
DEPARTMENT, DEPARTMENT OF
ENVIRONMENTAL QUALITY, OR AGENCY GOVERNING THE FACILITY OF POTABLE WATER,
WHICHEVER IS GREATER.
● WHERE 18” (450 MM) CANNOT BE MAINTAINED OR WHERE POTABLE WATER LINES CROSS
UNDER GRAVITY SEWERS,
RECLAIMED/REUSE MAINS, OR CHILLED WATER MAINS, ADDITIONAL PROTECTION SHALL BE
PROVIDED AS REQUIRED BY THE AGENCY GOVERNING THE FACILITY OF POTABLE WATER.
ADDITIONAL PROTECTION SHALL CONSIST OF CONSTRUCTING BOTH PIPING SYSTEMS WITH
DUCTILE IRON PIPE WITH RESTRAINED MECHANICAL JOINTS OR USE OF CONCRETE
ENCASEMENT. THE ADDITIONAL PROTECTION SHALL EXTEND A MINIMUM DISTANCE OF 10’-0” (3
M) OUTSIDE THE LIMITS OF THE CROSSING.
● SANITARY SEWER FORCE MAINS SHALL ONLY CROSS UNDER POTABLE WATER MAINS WITH
A MINIMUM VERTICAL CLEARANCE OF 18” (450 MM). WHEN THE VERTICAL CLEARANCE
BETWEEN THE POTABLE WATER MAIN AND THE FORCE MAIN IS LESS THAN 18” (450 MM), BOTH
THE WATER MAIN AND THE FORCE MAIN SHALL BE CONSTRUCTED WITH RESTRAINED
MECHANICAL JOINT DUCTILE IRON PIPE AS INDICATED ABOVE FOR ADDITIONAL PROTECTION.
● THE PREFERRED VERTICAL CLEARANCE BETWEEN DUCT BANKS AND PIPED UTILITIES
SHALL BE 2’-0” (300 MM) AND THE
MINIMUM VERTICAL CLEARANCE SHALL BE 18” (450 MM).
● THE MINIMUM VERTICAL CLEARANCE TO ALL STEAM, PUMPED CONDENSATE, AND HOT
WATER, AND OTHER UTILITIES SHALL BE AT LEAST 18” (450 MM). WHEN THIS VERTICAL
CLEARANCE CANNOT BE MAINTAINED, THE INSULATION THICKNESS ON THE STEAM,
CONDENSATE, OR HOT WATER MAIN SHALL BE INCREASED BY 50%.
BACK OF CURB
PLAN
TYPICAL SECTION
FLOWLINE
WEAKENED
PLANE JOINTS
SEE STANDARD DRAWING
10' (TYP.) 10'
1"
17"
6"7"
NOTES:
1. 1" BATTER ON GUTTER FACE OPTIONAL.
2. WHERE LONGITUDINAL SLOPE IS LESS THAN
0.4%, THE FLOW LINE SHALL BE WATER
TESTED.
1/2" R
12"
6" 1"
1/4"
1" R
CONCRETE
1/2" R
1"
25"
1-1/2" 4-1/2"
4-1/2" 6"
1-1/2"
SEE
NOTE 1
NUMBER 234 1/2" EXPANSION JOINT AT ALL COLD JOINTS, AT
BEGINNING AND END OF RETURN AND AT 300'
MAX. INTERVALS FOR EXTRUDED CURB AND 30'
MAX. INTERVALS FOR FORMED CURB.
2" ASPHALTIC CONCRETE PAVEMENT,
1 LIFTS
6" AGGREGATE BASE COURSE MATERIAL
SUBGRADE PREPARED PER
GEOTECHNICAL
RECOMMENDATIONS
GRADE
2" CHECK VALVE WITH TRIM
2" GROOVED BUTTERFLY VALVE
WITH TAMPER SWITCH
THRUST BLOCK
4" X 2" GROOVED CONCENTRIC
REDUCER
2" FLOW SWITCH
6" ELECTRIC BELL, COORDINATE
LOCATION WITH MODULAR
MANUFACTURER
1" MAIN DRAIN
4-WAY BRACE
2" GROOVED SWING CHECK VALVE
2" SINGLE SNOOT FDC.
HYDRAULIC CALC
DATA PLATE
UNDERGROUND
SHOWN AT ANGLE FOR
CLARITY
1" INSPECTORS TEST VALVE TO A 1"
SIGHT GLASS WITH A RESTRICTING
ORIFICE EQUAL TO THE DISCHARGE
OF THE SMALLEST SPRINKLER
ORIFICE INSTALLED ON THE SYSTEM
BEING TESTED. DRAIN LINE TO
CONNECT INTO MAIN DRAIN LINE.
SLIP COUPLING
4" STAINLESS STEEL RISER
SPARE HEAD CABINET
W/EXTRA HEADS
AND APPROPRIATE HEAD
WRENCHES. LOCATE INSIDE
MODULAR, COORDINATE
LOCATION WITH MODULAR
MANUFACTURER
TO MODULAR SYSTEM
SPLASH BLOCK
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Mechanical, Electrical and Plumbing:
B
IM
/5
-1
-2
E x p a n d
E D
B e d s
/5
-1
-2
.S
IT
E .r v t
/1
/2
:5
:5
A
M
CS501
CIVIL DETAIL SHEET 1
TRIPLE C - THE A-E GROUP
4401 Atlantic Avenue, Suite 200
Long Beach, CA 90807
562.452.7175
MAT PERKINS
REMODEL ED BEDS FOR
OBSERVATION BEDS
2615 E. CLINTON AVE., FRESNO, CA 93703
570-17-210
OPC
06/18/2021
100% FINAL
DOCUMENTS
NTS
C1
TRENCH DETAIL
NTS
F8
CONSTRUCTION AND SAFETY SIGN
UTILITY SEPERATION NOTES:
NTS
F1
VERTICAL CURB AND GUTTER
NTS
D3
ASPHALT PAVING
Revisions: Date:
1/8" = 1'-0" F3
MODULAR EXTERIOR FIRE RISER
TURLOCK IRRIGATION
DISTRICT
48" x 54" x 6"
TRANSFORMER PAD
SINGLE PHASE
U-2054-1
54"48"
15"
26"
11"
6"
58" 52"
1/2" THREADED
INSERTS
2 TOTAL
8"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Mechanical, Electrical and Plumbing:
B
IM
/5
-1
-2
E x p a n d
E D
B e d s
/5
-1
-2
.S
IT
E .r v t
/1
/2
:5
:5
A
M
CS502
CIVIL DETAIL SHEET 2
TRIPLE C - THE A-E GROUP
4401 Atlantic Avenue, Suite 200
Long Beach, CA 90807
562.452.7175
MAT PERKINS
REMODEL ED BEDS FOR
OBSERVATION BEDS
2615 E. CLINTON AVE., FRESNO, CA 93703
570-17-210
OPC
06/18/2021 M. PERKINS K.
STRUBLE
100% FINAL
DOCUMENTS
NTS
B9
TRNSFORMER PAD
GENERAL
THESE GENERAL NOTES SUPPLEMENT THE REQUIREMENTS OF THE PROJECT SPECIFICATIONS. IN CASE OF CONFLICT WITH THE SPECIFICATIONS, CONTACT THE OWNER’S REPRESENTATIVE PRIOR TO PROCEEDING
WITH THE WORK.
THE CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH THE SITE AND LOCAL CONDITIONS.
CONSTRUCTION SHALL BE PERFORMED IN ACCORDANCE WITH LOCAL BUILDING CODES, CODES OF
APPLICABLE REGULATORY AGENCIES, AND WITH PROJECT SPECIFICATIONS AND DRAWINGS.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF ALL TRADES AND FOR CHECKING ALL DIMENSIONS. REPORT DISCREPANCIES TO THE OWNER’S REPRESENTATIVE FOR CLARIFICATION PRIOR TO
PROCEEDING WITH THE WORK.
THE CONTRACTOR SHALL COMPLY WITH LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF
ANY PUBLIC AUTHORITY BEARING UPON THE PERFORMANCE OF THE WORK.
SUBJECT TO THE STRUCTURAL ENGINEER'S ACCEPTANCE, UTILIZE DETAILS FOR SIMILAR CONDITIONS WHEN
DETAILS FOR CONSTRUCTION ARE NOT INDICATED FOR A SPECIFIC CONDITION.
DETAILS ON SHEETS TITLED “TYPICAL DETAILS” APPLY TO SITUATIONS OCCURRING ON THE PROJECT THAT ARE THE SAME OR SIMILAR TO THOSE SPECIFICALLY REFERENCED. TYPICAL DETAILS ARE NOT NOTED AT
EACH LOCATION AT WHICH THEY ARE APPLICABLE.
WHERE NOT INDICATED ON THE STRUCTURAL DRAWINGS, SEE THE ARCHITECTURAL, CIVIL, MECHANICAL, ELECTRICAL, PLUMBING, FIRE PROTECTION, AND ANY OTHER DRAWINGS FOR:
ELEVATIONS AND SLOPES,
SIZE, LOCATION AND EXTENT OF CURBS, FLOOR DEPRESSIONS, AND TOPPING SLABS,
SIZE AND LOCATION OF DRAINS, TRENCHES, SLAB OPENINGS, AND WALL OPENINGS,
SIZE, TYPE AND LOCATION OF NON-LOAD BEARING PARTITIONS,
CONCRETE AND STEEL FINISHES,
SIZE AND LOCATION OF SLEEVES AND HANGERS,
ITEMS EMBEDDED IN THE STRUCTURE OR PENETRATING THE STRUCTURE,
CONNECTION OF ARCHITECTURAL, CIVIL, MECHANICAL, ELECTRICAL, PLUMBING, FIRE
PROTECTION OR ANY OTHER ITEMS TO THE STRUCTURE AND CONNECTION OF ITEMS
NOT TYPICALLY DETAILED ON THE STRUCTURAL DRAWINGS,
WATERPROOFING AND DAMP PROOFING,
SITE AND SUBGRADE DRAINAGE SYSTEMS AND DETAILS.
CONNECTIONS OF ALL TRADES TO THE STRUCTURE SHALL BE DESIGNED AND DETAILED BY THE
CONTRACTOR. CONNECTIONS TO STRUCTURAL MEMBERS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR REVIEW. RESPONSIBILITY FOR THE PERFORMANCE OF THE SUPPLIED SYSTEM AND ASSOCIATED CONNECTIONS SHALL REMAIN THAT OF THE CONTRACTOR. ALL CONNECTIONS SHALL BE
DESIGNED BY AN ENGINEER LICENSED IN THE STATE IN WHICH THE PROJECT IS LOCATED.
OPENINGS AND PENETRATIONS THROUGH STRUCTURAL ELEMENTS AND ITEMS EMBEDDED IN STRUCTURAL ELEMENTS THAT ARE NOT INDICATED ON THE STRUCTURAL DRAWINGS SHALL BE REVIEWED BY STRUCTURAL
ENGINEER PRIOR TO IMPLEMENTING WORK.
DO NOT SCALE DRAWINGS TO DETERMINE DIMENSIONAL INFORMATION.
DO NOT PLACE MATERIALS OR EQUIPMENT ON UNFINISHED FLOORS OR ROOFS IN EXCESS OF 20 PSF NOR ON FINISHED FLOORS OR ROOFS IN EXCESS OF THE INDICATED DESIGN LIVE LOADS. AVOID IMPACT LOADING.
THE STRUCTURE WAS DESIGNED FOR THE IN-SERVICE CONDITIONS ONLY. THE METHODS, PROCEDURES AND SEQUENCES OF CONSTRUCTION ARE THE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO MAINTAIN AND ENSURE THE INTEGRITY OF THE STRUCTURE AT ALL
STAGES OF CONSTRUCTION.
DRAWINGS DO NOT INDICATE TEMPORARY REQUIREMENTS. NEED FOR TEMPORARY SHORING AND BRACING, TEMPORARY DEWATERING, TEMPORARY EARTH RETENTION, TEMPORARY WATER CUTOFF OR OTHER
TEMPORARY MEASURES MAY BE INDICATED ON DRAWINGS AT SELECTED AREAS AS SUGGESTIONS FOR THE CONTRACTOR'S CONVENIENCE. THE DRAWINGS DO NOT IDENTIFY ALL AREAS OR CONDITIONS REQUIRING TEMPORARY MEASURES. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONFIRM TEMPORARY MEASURES INDICATED ON THE DRAWINGS, IDENTIFY OTHER AREAS OR CONDITIONS REQUIRING TEMPORARY MEASURES, DETERMINE MOST EFFICIENT TEMPORARY SYSTEMS, AND DESIGN AND CONSTRUCT REQUIRED TEMPORARY SYSTEMS. ALL TEMPORARY SYSTEMS SHALL BE DESIGNED BY A LICENSED ENGINEER IN THE STATE IN WHICH
THE PROJECT IS LOCATED.
INFORMATION RELATED TO EXISTING CONDITIONS REPRESENTS KNOWLEDGE BASED UPON INFORMATION PROVIDED BY THE OWNER BUT WITHOUT GUARANTEE OF ACCURACY. REPORT EXISTING CONDITIONS THAT VARY FROM THOSE SHOWN ON THE CONTRACT DOCUMENTS TO THE OWNER’S REPRESENTATIVE. DO NOT
DEVIATE FROM THE CONTRACT DOCUMENTS WITHOUT WRITTEN DIRECTION FROM THE OWNER’S
REPRESENTATIVE.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO EXISTING CONSTRUCTION WHILE PERFORMING WORK. THE CONTRACTOR SHALL PROPERLY REINSTATE EXISTING FINISHES, FIREPROOFING OR ITEMS THAT
ARE REMOVED OR DAMAGED WHILE PERFORMING WORK.
UNLESS NOTED OTHERWISE, ELEVATIONS ON THE DRAWINGS ARE RELATIVE TO THE ELEVATION OF THE FIRST FLOOR, WHICH IS PROJECT ELEVATION 0'-0". FOR EXISTING CONDITIONS, ALL REFERENCE ELEVATIONS ARE NOTED ON DRAWINGS AND NEED TO BE FIELD VERIFIED PRIOR TO START OF CONSTRUCTION.
DESIGN CRITERIA
ALL CONSTRUCTION SHALL CONFORM TO THE MORE RESTRICTIVE OF THE FOLLOWING CODES, THE MOST RECENT EDITIONS OF THE STANDARDS ADOPTED BY U.S. DEPARTMENT OF VERTERANS AFFAIRS (VA) OR THE AUTHORITY HAVING JURISDICTION AS REFERENCED THROUGHOUT THE STRUCTURAL
GENERAL NOTES, AND THE FOLLOWING DESIGN CRITERIA:
BUILDING CODE: 2015 INTERNATIONAL BUILDING CODE WITH LOCAL AMENDMENTS
BUILDING OCCUPANCY CATEGORY (IBC TABLE 1604.5): IV
DESIGN DEAD LOADS: SELF-WEIGHT OF MATERIALS AND SYSTEMS
DESIGN LIVE LOADS (REDUCIBLE WHERE ALLOWED PER BUILDING CODE):
FLOORS: 100 PSF
WALKWAYS AND ELEVATED PLATFORMS (OTHER THAN EXIT WAYS): 60 PSF
DESIGN WIND LOADS:
LATERAL LOAD RESISTANCE SYSTEM (BUILDING CODE):
BASIC WIND SPEED: 115 MILES PER HOUR
WIND IMPORTANCE FACTOR, IW: 1.0
WIND EXPOSURE: C
INTERNAL PRESSURE COEFFICIENT: +0.18, -0.18
DESIGN SEISMIC LOADS:
SITE CLASS: D
SEISMIC IMPORTANCE FACTOR, IE: 1.5
MAPPED SPECTRAL RESPONSE ACCELERATION, SS: 0.634G
MAPPED SPECTRAL RESPONSE ACCELERATION, S1: 0.257G
SPECTRAL RESPONSE COEFFICIENT, SDS: 0.546G
SPECTRAL RESPONSE COEFFICIENT, SD1: 0.323G
SEISMIC DESIGN CATEGORY: D
ANALYSIS PROCEDURE USED: NONBUILDING STRUCTURALS (ASCE 7 SECTION 15)
NON-STRUCTURAL COMPONENTS: PER ASCE7 SECTION 13, THE SEISMIC DESIGN CATEGORY OF D
SEISMIC DESIGN REQUIREMENTS FOR MECHANICAL AND ELECTRICAL COMPONENTS, AND FOR
ARCHITECTURAL COMPONENTS WITH IMPORTANCE FACTORS OF 1.5. REFER TO RESPECTIVE
DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL INFORMATION.
MODIFICATIONS TO EXISTING CONSTRUCTION
THE EXISTING CONSTRUCTION SHOWN ON THESE DRAWINGS IS PROVIDED FOR REFERENCE ONLY. EXISTING CONSTRUCTION SHALL BE VERIFIED IN THE FIELD PRIOR TO FABRICATION AND ERECTION OF ALL NEW
CONSTRUCTION.
ANY EXISTING FINISHES REMOVED OR DAMAGED TO ACCOMPLISH ANY STRUCTURAL MODIFICATIONS SHALL BE REINSTATED AT THE COMPLETION OF MODIFICATION WORK, TYPICAL UNLESS NOTED OTHERWISE.
ANY STRUCTURAL STEEL OR REINFORCING BARS THAT HAVE BEEN CUT AND GROUND FLUSH WITH A
CONCRETE SURFACE SHALL BE FINISHED WITH EPOXY PAINT.
THE FACE OF ALL NEW PERMANENT CONCRETE SURFACES CUT FROM EXISTING CONCRETE SHALL BE CLEANED WITH A HIGH PRESSURE WATER SPRAY. ALLOW SURFACES TO DRY THOROUGHLY. COAT THE CONCRETE SURFACES WITH A BONDING AGENT AND FINISH WITH AN ACCEPTABLE PATCHING COMPOUND.
ALL EXPOSED REINFORCEMENT SHALL BE GROUND FLUSH WITH THE NEW CONCRETE SURFACE.
WHERE EXISTING CONCRETE REINFORCEMENT IS TO BE REUSED IN-PLACE, THE CONCRETE SHALL BE REMOVED IN A MANNER THAT MINIMIZES DAMAGE TO THE REINFORCEMENT. DAMAGED REINFORCEMENT
SHALL BE REPLACED BY A METHOD ACCEPTABLE TO THE STRUCTURAL ENGINEER.
WHERE NEW CONCRETE IS TO BE CAST AGAINST EXISTING CONCRETE, THE CONTACT SURFACE SHALL BE ROUGHENED AND CLEANED WITH A HIGH PRESSURE WATER SPRAY. ALLOW TO DRY THOROUGHLY PRIOR TO
APPLICATION OF EPOXY BONDING AGENT.
ANY NEW STRUCTURAL STEEL REINFORCEMENT BEAMS ADJACENT TO NEW SLAB OPENINGS SHALL BE FULLY
INSTALLED PRIOR TO ANY CUTTING FOR THE OPENINGS.
PRIOR TO CUTTING OPENINGS IN ENTIRE SLAB SPANS, ALL ADJACENT SPANS SHALL BE SHORED
TEMPORARILY OR AS INDICATED.
ANY EXISTING WALL OPENINGS TO BE INFILLED SHALL BE REINFORCED WITH BARS TO MATCH THOSE IN THE ADJACENT EXISTING CONCRETE. DOWELS FOR THOSE BARS SHALL BE PLACED INTO ADJACENT CONCRETE.
PRIOR TO CUTTING OPENINGS IN EXISTING WALLS, ANY ADJACENT IN-FILL WORK SHALL BE COMPLETED AND THE IN-FILL CONCRETE SHALL HAVE REACHED ITS REQUIRED 28-DAY COMPRESSIVE STRENGTH.
SAWCUTS FOR NEW WALL OPENINGS SHALL NOT EXTEND PAST THE REQUIRED DIMENSIONS FOR THE OPENING. CORE DRILL THE CORNERS AND EXTEND SAW CUTS INTO THE CORED AREAS AND NOT BEYOND IT.
CHIP OUT THE REMAINDER AT THE CORNERS TO ACHIEVE A CLEAN 90 DEGREE CORNER.
THE LOCATION AND LENGTH OF ANY NEW STEEL FRAMING SHALL BE COORDINATED WITH THE EXISTING STEEL DECK SLABS AND ROOF DECKS SUCH THAT THE NEW STRUCTURAL STEEL BEAM CENTERLINES
CORRESPOND WITH THE RIBS OF THE STEEL DECK.
THE CONTRACTOR SHALL SUBMIT COORDINATED SHOP DRAWINGS TO THE STRUCTURAL ENGINEER FOR
APPROVAL PRIOR TO CUTTING OR ERECTION OF ANY NEW STRUCTURAL STEEL.
VERIFY ACCESSILITY TO THE BUILDING AND MAXIMUM WORKABLE MEMBER LENGTHS BEFORE COMMENCING WITH FABRICATION. IF THE NEW STRUCTURAL ELEMENTS CANNOT BE SHIPPED AND INSTALLED AS CONTINUOUS MEMBERS, ANY SPLICES SHALL CONSIST OF COMPLETE PENETRATION WELDING OF THE FLANGES AND PARTIAL PENETRATION WELDING OF THE WEB OF THE NEW BEAM. THE CONTRACTOR SHALL SUBMIT PROPOSED SPLICE DETAILS AND LOCATIONS TO THE STRUCTURAL ENGINEER FOR REVIEW AND
APPROVAL PRIOR TO FABRICATION.
REMOVE ALL LOADS FROM THE SLAB DIRECTLY ABOVE THE AREAS WHERE NEW STEEL BEAMS ARE TO BE INSTALLED. PROVIDE SHORING UNDER EXISTING SLABS AND BEAMS PRIOR TO AND DURING CONSTRUCTION.
ALL NEW STRUCTURAL STEEL SHALL BE IN PLACE PRIOR TO THE REMOVAL OF ANY EXISTING SLABS AND/OR
SHORING.
PROVIDE NON-SHRINK GROUT AS REQUIRED FOR FULL BEARING OF THE EXISTING SLAB ON THE NEW BEAMS, UNLESS NOTED OTHERWISE.
REMOVE EXISTING FIREPROOFING LOCALLY AND CLEAN AREAS OF EXISTING STEEL TO BE WELDED. INSTALL NEW U.L. APPROVED FIREPROOFING MATERIAL ON ALL NEW STEEL AND ANY AREAS WHERE FIREPROOFING WAS REMOVED OR DAMAGED DURING THE INSTALLATION OF THE WORK. NEW STEEL SHALL HAVE A FIRE RATING TO MATCH THE ADJACENT EXISTING STEEL, TYPICAL UNLESS NOTED OTHERWISE. REFER TO
ARCHITECTURAL DOCUMENTS FOR REQUIRED FIRE RATINGS.
POST-INSTALLED ANCHORS
CONCRETE MECHANICAL ANCHORS SHALL BE WEDGE EXPANSION TYPE, MADE OF STEEL, HILTI KWIK-BOLT TZ2 EXPANSION ANCHOR, AS MANUFACTURED BY HILTI, INC. (ICC ES ESR-1917) OR APPROVED EQUAL.
CONCRETE ADHESIVE ANCHORS SHALL BE HILTI HIT-RE 500 V3 ADHESIVE ANCHORAGE SYSTEMS, AS MANUFACTURED BY HILTI, INC. (ICC ES ESR-3814) OR APPROVED EQUAL, TYPICAL UNLESS NOTED OTHERWISE. THREADED RODS USED IN ADHESIVE ANCHORAGE SYSTEMS SHALL MEET THE REQUIREMENTS OF ASTM A193, GRADE B7. REINFORCING BARS USED IN ADHESIVE ANCHORAGE SYSTEMS SHALL BE ASTM A615, GRADE 60 REINFORCING BARS. REMOVE GREASE, OIL, RUST, AND OTHER LAITANCE FROM RODS AND DOWELS PRIOR TO INSTALLATION. CONCRETE ADHESIVE ANCHORS LOCATED WITHIN CLEANROOMS SHALL BE HILTI HIT-HY 200-R ADHESIVE ANCHORAGE SYSTEMS, AS MANUFACTURED BY HILTI, INC. (ICC ES ESR-3187).
PROVIDE STAINLESS STEEL FASTENERS FOR EXTERIOR USE OR WHEN EXPOSED TO WEATHER. PROVIDE
GALVANIZED CARBON STEEL ANCHORS AT OTHER LOCATIONS, UNLESS OTHERWISE NOTED.
IF REINFORCEMENT IS ENCOUNTERED DURING DRILLING, ABANDON AND SHIFT THE HOLE LOCATION TO AVOID THE REINFORCEMENT. PROVIDE A MINIMUM OF 2 ANCHOR DIAMETERS OR 1 INCH, WHICHEVER IS LARGER, OF SOUND CONCRETE BETWEEN THE DOWEL AND THE ABANDONED HOLE. FILL THE ABANDONED HOLE WITH NON-SHRINK GROUT. IF THE ANCHOR OR DOWEL MAY NOT BE SHIFTED AS NOTED, THE
ENGINEER WILL DETERMINE A NEW LOCATION.
LOCATE REINFORCEMENT AND CONFIRM FINAL ANCHOR LOCATIONS PRIOR TO FABRICATING PLATES, MEMBERS, OR OTHER STEEL ASSEMBLIES ATTACHED WITH MECHANICAL ANCHORS.
ALL POST-INSTALLED ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S
INSTALLATION INSTRUCTIONS AND THE APPLICABLE ICC EVALUATION SERVICES REPORT.
STRUCTURAL STEEL
ALL STRUCTURAL STEEL SHALL BE FABRICATED BY A FABRICATOR WITH ONE OF THE FOLLOWING MINIMUM QUALIFICATIONS AND BE APPROVED BY AUTHORITY HAVING JURISDICTION (AHJ). QUALIFICATIONS SHALL BE IN
EFFECT AT TIME OF BID.
INTERNATIONAL ACCREDITATION SERVICE, INC. (IAS) APPROVED FABRICATOR
AISC CERTIFIED FABRICATOR (STD)
AHJ CERTIFIED FABRICATOR
FABRICATOR SHALL SUBMIT DOCUMENTATION OF THEIR CERTIFICATION WITH THE FIRST SHOP DRAWING
SUBMITTAL.
STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED AND ERECTED IN ACCORDANCE WITH AISC 360 “SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS” AND AISC 303 “CODE OF STANDARD PRACTICE FOR STEEL
BUILDINGS AND BRIDGES” USING LOAD AND RESISTANCE FACTOR DESIGN (LRFD).
STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING DESIGNATED ASTM STANDARDS:
WIDE FLANGES: ASTM A 992
HOLLOW STRUCTURAL SECTIONS (HSS): ASTM A500, GRADE C
CHANNELS AND ANGLES: ASTM A 36
PLATES: ASTM A 36, TYPICAL U.N.O.
BOLTED CONNECTIONS SHALL BE DESIGNED AND INSTALLED USING HIGH-STRENGTH BOLTS IN ACCORDANCE WITH THE RCSC "SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A 325 OR A 490 BOLTS”. USE ASTM A 325 BOLTS IN BEARING-TYPE CONNECTIONS WITH THREADS PERMITTED IN THE SHEAR PLANE (TYPE N), UNLESS OTHERWISE NOTED. WASHERS SHALL CONFORM TO ASTM F 436. CONNECTIONS MAY BE SNUG-TIGHTENED, UNLESS NOTED
OTHERWISE.
CONNECTIONS FOR THE FOLLOWING STRUCTURAL ELEMENTS SHALL BE SLIP CRITICAL CONNECTIONS:
CONNECTIONS WITH OVERSIZED HOLES
CONNECTIONS WITH SLOTTED HOLES THAT ARE NOT PERPENDICULAR TO THE APPLIED
LOAD.
SLIP CRITICAL CONNECTIONS AND PRE-TENSIONED CONNECTIONS SHALL BE INSTALLED USING DIRECT TENSION INDICATORS CONFORMING TO ASTM F 959 OR TWIST-OFF-TYPE TENSION-CONTROL BOLTS CONFORMING TO ASTM F
1852 OR ASTM F 2280.
ALL CONNECTION FORCES INDICATED ON THE DRAWINGS ARE FACTORED LOADS ACCORDING TO THE LOAD AND
RESISTANCE FACTOR DESIGN (LRFD) METHOD.
DETAILS OF SIMPLE SHEAR CONNECTIONS REQUIRED BY THE CONTRACT DOCUMENTS SHALL BE PROVIDED BY THE STRUCTURAL STEEL FABRICATOR AND INCLUDE COMPREHENSIVE ENGINEERING ANALYSIS BY A QUALIFIED PROFESSIONAL ENGINEER LICENSED IN THE STATE IN WHICH THE PROJECT IS LOCATED. CONNECTION DETAILS MAY BE SELECTED OR COMPLETED USING SCHEMATIC DETAILS INDICATED ON THE DRAWINGS AND THE SECTIONS REGARDING CONNECTIONS IN THE AISC "MANUAL OF STEEL CONSTRUCTION" AND DESIGNED USING THE LRFD
METHOD TO WITHSTAND THE REACTION FORCES INDICATED.
BOLTED CONNECTIONS DETAILED IN THE FINAL CONDITION TO PERMIT SLIP BETWEEN CONNECTED ELEMENTS SHALL BE TIGHTENED FINGER TIGHT. NOTCH FIRST BOLT THREAD PROJECTING FROM THE NUT OR INSTALL A JAM NUT.
WELDING SHALL CONFORM TO STANDARDS OF AWS D1.1 “STRUCTURAL WELDING CODE—STEEL: TYPICAL AND AWS D1.8 “STRUCTURAL WELDING CODE—SEISMIC SUPPLEMENT” WHERE SPECIFIED. ELECTRODES FOR FIELD AND SHOP WELDING SHALL CONFORM TO AWS RECOMMENDATIONS. WELDS NOT INDICATED ON THE DRAWINGS SHALL BE AWS MINIMUM OR AS REQUIRED TO SATISFY STRENGTH CRITERIA, WHICHEVER IS GREATER. FOLLOW PREHEAT REQUIREMENTS OF AWS. TO MINIMIZE THE USE OF PREHEAT, LOW HYDROGEN ELECTRODES MAY BE UTILIZED.
LOW HYDROGEN ELECTRODES SHALL BE USED FOR WELDING TO CONCRETE EMBEDMENT PLATES OR OTHER
STRUCTURAL STEEL ELEMENT IN CONTACT WITH CONCRETE OR MASONRY.
ARC-WELDING ELECTRODES AND FILLER METALS TO BE LOW HYDROGEN TYPES E7XTX, E7XTXX OR E70XXX MINIMUM AS APPLICABLE. ELECTRODES WITH CHARPY V-NOTCH (CVN) TESTS VALUES OF A MINIMUM 20 FOOT-POUNDS AT -20 DEGREES FAHRENHEIT AND 40 FT-POUNDS AT 70 DEGREE FAHRENHEIT SHALL BE USED AT THE FOLLOWING
LOCATIONS:
COMPLETE JOINT PENETRATION WELDS
BEAM TO COLUMN MOMENT CONNECTIONS INCLUDING FLANGE, WEB, AND CONTINUITY
PLATE FILLET AND PARTIAL JOINT PENETRATION WELDS
BRACE CONNECTIONS INCLUDING BRACE, GUSSET, BASE PLATES, BEAM STIFFENER
PLATES, AND CONTINUITY PLATE FILLET AND PARTIAL JOINT PENETRATION WELDS
WELDS NOTED AS DEMAND-CRITICAL (DC) ON THE DRAWINGS
WELDERS SHALL BE CERTIFIED BY AWS AND THE APPLICABLE AUTHORITY HAVING JURISDICTION.
GENERALLY, DRAWINGS DO NOT DISTINGUISH BETWEEN SHOP-WELDING AND FIELD-WELDING. THE CONTRACTOR SHALL DETERMINE THE MOST ECONOMICAL, EFFICIENT AND PRACTICAL COMBINATIONS OF SHOP-WELDING AND
FIELD-WELDING.
SPLICING STRUCTURAL MEMBERS WHERE NOT DETAILED ON STRUCTURAL DRAWINGS IS PROHIBITED WITHOUT PRIOR ACCEPTANCE BY CONTRACTING OFFICERS REPRESENTATIVE AND THE STRUCTURAL ENGINEER.
OPENINGS AND SLEEVES IN STRUCTURAL STEEL MEMBERS SHALL BE SHOP CUT ONLY. FIELD BURNING, CUTTING, RE-DRILLING OR OTHER FIELD MODIFICATION IS NOT PERMITTED ON STRUCTURAL STEEL MEMBERS WITHOUT PRIOR
ACCEPTANCE OF THE CONTRACTING OFFICERS REPRESENTATIVE AND STRUCTURAL ENGINEER.
THE STEEL FRAME FOR THIS BUILDING IS CLASSIFIED AS NON-SELF-SUPPORTING PER SECTION 7.10 OF THE AISC 303 “CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES", AND REQUIRES INTERACTION WITH THE STEEL BRACING, ASSOCIATED FLOOR BEAMS, METAL DECK FLOOR SLAB AND STEEL ROOF DECK TO PROVIDE LATERAL STABILITY. THE CONTRACTOR SHALL PROVIDE ADEQUATE TEMPORARY BRACING TO RESIST THE CODE REQUIRED WIND AND SEISMIC LOADS SHOWN ON THE DRAWINGS UNTIL ALL FINAL CONNECTIONS OF THE STEEL FRAMING, BRACING, COMPOSITE STEEL DECK FLOOR SLAB, AND STEEL ROOF DECK HAVE BEEN COMPLETED.
SEE ARCHITECTURAL DRAWINGS FOR FIREPROOFING REQUIREMENTS. FOR FIREPROOFING PURPOSES, FRAMING SHALL BE CONSIDERED EITHER "UNRESTRAINED" OR “RESTRAINED” DEPENDING ON STRUCTURAL SYSTEM AS
DEFINED IN ASTM E 119 AND UL 263.
ALL STRUCTURAL STEEL EXCEPT EMBEDDED STEEL WHICH IS IN CONTACT WITH CONCRETE, STEEL TO BE FIREPROOFED, AND STEEL TO BE GALVANIZED SHALL BE CLEANED AND SHOP-PRIMED AS INDICATED IN THE PROJECT SPECIFICATIONS. SEE THE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR FINISH PAINTING
REQUIREMENTS.
UNLESS SPECIFICALLY SHOWN TO BE PAINTED, GALVANIZE ALL EXTERIOR STRUCTURAL STEEL. PROVIDE GALVANIZING AS INDICATED IN THE PROJECT SPECIFICATIONS. TOUCH-UP GALVANIZING WITH GALVANIZING REPAIR
PAINT AS INDICATED IN THE PROJECT SPECIFICATIONS.
COLD FORMED METAL FRAMING
ALL COLD-FORMED STEEL FRAMING SHALL BE DESIGNED AND DETAILED BY THE CONTRACTOR. ALL COLD- FORMED STEEL FRAMING SHALL BE DESIGNED BY AN ENGINEER LICENSED IN THE STATE IN WHICH THE PROJECT IS LOCATED. SUBMIT STAMPED SHOP DRAWINGS AND CALCULATIONS TO THE ENGINEER OF RECORD FOR APPROVAL INDICATING ALL COLD-FORMED STEEL MEMBERS, CONNECTIONS, FASTENERS, OPENINGS AND
OTHER COLD-FORMED STEEL RELATED ITEMS.
ALL COLD-FORMED STEEL FRAMING SHALL BE DESIGNED, FABRICATED AND ERECTED IN ACCORDANCE WITH MANUFACTURER’S RECOMMENDATIONS AND IN ACCORDANCE WITH THE LATEST EDITION OF AISI 100 “NORTH
AMERICAN SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS”.
STEEL FOR 14 AND 16 GAGE STUDS AND JOISTS AND FOR ALL DIAGONAL TENSION STRAPS SHALL HAVE A MINIMUM YIELD STRENGTH OF 50 KSI. STEEL FOR ALL 18 AND 20 GAGE STUDS AND JOISTS AND FOR ALL GAGES OF TRACK, ACCESSORIES, AND BRIDGING SHALL HAVE A MINIMUM YIELD STRENGTH OF 33 KSI.
ALL STUDS SHALL BE SECURELY SEATED FOR FULL END BEARING ON TOP AND BOTTOM TRACK. UNLESS NOTED OTHERWISE, PROVIDE DOUBLE STUDS AT ALL JAMBS, CORNERS, INTERSECTIONS, BEAM BEARINGS, AND JOIST BEARINGS. DO NOT NOTCH FLANGES OF JOISTS OR STUDS.
ALL COLD-FORMED METAL FRAMING SHALL BE G60 GALVANIZED, TYPICAL. COLD-FORMED METAL FRAMING SUPPORTING ANCHORED VENEER AT EXTERIOR WALLS SHALL BE G90 GALVANIZED. ALL CONNECTION SCREWS
SHALL BE ZINC COATED.
ALL COLD-FORMED METAL FRAMING AND POWDER-DRIVEN FASTENERS SHALL BE ICC-APPROVED. ALL WELDING SHALL BE PERFORMED IN ACCORDANCE WITH AWS D1.3, "STRUCTURAL WELDING CODE-SHEET
STEEL" BY WELDERS EXPERIENCED IN LIGHT GAGE STRUCTURAL STEEL FRAMING WORK.
STUDS SHALL BE FASTENED TO TRACK WITH A MINIMUM OF (2) #10-16 SELF -DRILLING SCREWS WITH STUD
SECURELY INTO TRACK.
TRACK SHALL BE FASTENED TO STRUCTURAL STEEL WITH A MINIMUM OF 1/8" WELD EACH SIDE, 2" LONG
SPACED AT 32" OC OR (2) 0.145" DIA POWDER ACTUATED FASTENERS AT 16" OC.
TRACK SHALL BE FASTENED TO CONCRETE WITH A MINIMUM OF (2) 0.145" DIA POWDER ACTUATED FASTENERS THROUGH TRACK AT EACH STUD. PROVIDE 1 1/2" MINIMUM EMBEDMENT, 4” MINIMUM SPACING, AND 3” MINIMUM
CONCRETE EDGE DISTANCE.
MAINTAIN 3/4" MINIMUM DISTANCE BETWEEN CENTERS OF CONNECTION SCREWS AND 3/4" MINIMUM DISTANCE FROM THE CENTER OF SCREW TO EDGE OF CONNECTED PART. INSTALL FASTENERS FROM THINNER THROUGH
THICKER MATERIAL.
PROVIDE MECHANICAL BRIDGING AT INTERVALS NOT EXCEEDING 4'- 0" ON CENTER AT ALL COLD-FORMED
STEEL WALLS. BRIDGING SHALL BE IN PLACE PRIOR TO PLACING ANY LOADS ON THE WALL.
FIELD MODIFICATIONS OF COLD-FORMED STEEL SYSTEMS SHALL NOT BE ALLOWED WITHOUT PRIOR WRITTEN
APPROVAL OF THE ENGINEER OF RECORD.
ABBREVIATIONS
AB ANCHOR BOLT(S)
ACI AMERICAN CONCRETE INSTITUTE
ADDL ADDITIONAL
AESS ARCHITECTURALLY EXPOSED STRUCTURAL STEEL
AFF ABOVE FINISH FLOOR
AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION
ALT ALTERNATE
ALUM ALUMINUM
ARCH ARCHITECT OR ARCHITECTURAL DOCUMENTS
ASCE AMERICAN SOCIETY OF CIVIL ENGINEERS
ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS
AWS AMERICAN WELDING SOCIETY
AVG AVERAGE
BP BASE PLATE
B/CONC BOTTOM OF CONCRETE
B/FTG BOTTOM OF FOOTING
B/DECK BOTTOM OF DECK
BLDG BUILDING
B/MAT BOTTOM OF MAT
BPE BOTTOM OF PILE ELEVATION
B/SLAB BOTTOM OF SLAB
B/STL BOTTOM OF STEEL
CC CONCRETE COLUMN
CB CONCRETE BEAM
CALCS CALCULATIONS
CIP CAST IN PLACE
CJ CONTROL JOINT OR CONSTRUCTION JOINT
CJP COMPLETE JOINT PENETRATION
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
CENTERLINE
D COMPOSITE STEEL DECK / STEEL ROOF DECK / FORM DECK
Db DIAMETER OF REBAR
DBL DOUBLE
DEPR DEPRESSION
DEG DEGREE
DTL DETAIL
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DL DEAD LOAD
DN DOWN
DP DRILLED PIER
E MODULUS OF ELASTICITY
EA EACH
EF EACH FACE
EFEW EACH FACE, EACH WAY
EJ EXPANSION JOINT
ELEC ELECTRICAL
EL ELEVATION
EMB EMBEDMENT
EOS EDGE OF SLAB
EQ EQUAL
EQUIP EQUIPMENT
EW EACH WAY
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR
FDN FOUNDATION
FF FINISH FLOOR
FIN FINISH
FD FLOOR DRAIN
FLG FLANGE
FLR FLOOR
FRMG FRAMING
F.S. FOUNDATION STEP
FT FOOT (FEET)
FTG FOOTING
FY YIELD STRESS STEEL
G GRATING
GA GAGE OR GAUGE
GALV GALVANIZED
GB GRADE BEAM
HSA HEADED STUD ANCHOR
HORIZ HORIZONTAL
H.P. HIGH POINT
HS HIGH STRENGTH
HT HEIGHT
I (IN4 ) MOMENT OF INERTIA
IBC INTERNATIONAL BUILDING CODE
ICC INTERNATIONAL CODE COUNCIL
ID INSIDE DIAMETER
IN INCH
INFO INFORMATION
INT INTERIOR
JT JOINT
K KIP = 1000 LBS
KSI KIPS PER SQUARE INCH
L LEDGER
LBS POUND(S)
Ldh REBAR DEVELOPMENT LENGTH Lext REBAR STRAIGHT EXTENSION
L90 REBAR 90 DEGREE HOOK LENGTH
L135 REBAR 135 DEGREE HOOK LENGTH
L180 REBAR 180 DEGREE HOOK LENGTH
LL LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LSH LONG SIDE HORIZONTAL
LSV LONG SIDE VERTICAL
LP LOW POINT
LWC LIGHT WEIGHT CONCRETE
MATL MATERIAL
MAX MAXIMUM
MCJ MASONRY CONTROL JOINT
MECH MECHANICAL
MEZZ MEZZANINE
MFR MANUFACTURER
MID MIDDLE
MIN MINIMUM
MISC MISCELLANEOUS
MEP MECHANICAL, ELECTRICAL AND PROCESS
MTL METAL
MO MASONRY OPENING
NAAMM NATIONAL ASSOCIATION OF ARCHITECTURAL
METAL MANUFACTURERS
NF NEAR FACE
NIC NOT IN CONTRACT
NO NUMBER
NS NEAR SIDE
NTS NOT TO SCALE
O.C. ON CENTER
O.C.E.W. ON CENTER, EACH WAY
OPP OPPOSITE
PCI PRESTRESSED CONCRETE INSTITUTE
PC PILE/PIER CAP
PCF POUNDS PER CUBIC FOOT
PL PLATE
PLF POUNDS PER LINEAR FOOT
PSI POUNDS PER SQUARE INCH
PT, P/T POST-TENSIONED
PSF POUNDS PER SQUARE FOOT
QTY QUANTITY
RO ROOF OPENING
RAD RADIUS
REINF REINFORCED OR REINFORCING
SDI STEEL DECK INSTITUTE
SL SNOW LOAD
SIM SIMILAR
SJI STEEL JOIST INSTITUTE
SOG SLAB ON GRADE
SPEC SPECIFICATION
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STIFF STIFFENER
STL STEEL
SW SHEARWALL
T/BTM CHORD TOP OF BOTTOM CHORD
T&B TOP AND BOTTOM
T/CAP TOP OF CAP
T/CONC. TOP OF CONCRETE
T/CURB TOP OF CURB
T/DECK TOP OF DECK
T/FTG TOP OF FOOTING
T/GRADE TOP OF GRADE
T/GRATING TOP OF GRATING
TL TOTAL LOAD
T/MAT TOP OF MAT
T/PC TOP OF PILE CAP
T/PIER TOP OF PIER ELEVATION
T/SLAB TOP OF SLAB
T/S TOP OF STEEL
T/WALL TOP OF WALL ELEVATION
TYP TYPICAL
UL UNDERWRITERS LABORATORIES
UNO UNLESS NOTED OTHERWISE
UT ULTRASONIC TESTING
VERT VERTICAL
WP WORK POINT
WWR WELDED WIRE REINFORCEMENT
WF WALL FOOTING
W WALL
X-STRONG EXTRA STRONG
XX-STRONG DOUBLE EXTRA STRONG
# NUMBER
LEGEND
CONCRETE WALL.
FOR THICKNESS AND REINFORCING SEE WALL SCHEDULE.
INDICATES LIMITS OF OPENING
ONLY LATEST REVISION IS "CLOUDED"
LETTERS OR NUMBERS INDICATE
ADDENDA/BULLETINS
KEYED NOTE SYMBOL
INDICATES WORK, DATUM OR
CONTROL POINT
RFI
POPULATE FIELD IF THE RFI NUMBER
NEEDS TO BE SHOWN
COLD-FORMED STEEL STUD WALL.
FOR SIZE AND SPACING SEE WALL SCHEDULE.
COLD-FORMED STEEL STUD SHERWALL.
FOR SIZE AND SPACING SEE WALL SCHEDULE.HOLD-DOWN ANCHOR
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Appr…