5.4_-_Architecture.pdf
PDF 2 MB Posted
- Attached to
- CFD Station #344 HVAC Renovation
- Solicitation number
- IFB-2026-019
- Issued by
- Hamilton County, Indiana
About this file
This architectural document is a comprehensive set of construction drawings and specifications for the HVAC Replacement project at Carmel Fire Station #44, located at 5032 E Main St, Carmel, Indiana 46033. The project, identified as 2026-028.44H, involves replacement of the heating, ventilating, and air conditioning systems along with related electrical, controls, and ancillary work. The document includes detailed architectural abbreviations, general notes, demolition plans for basement, first, and second floors, overall floor plans showing room layouts across three levels, reflected ceiling plans with specifications for acoustical panel ceilings (APC-1, APC-2, APC-3) and gypsum wallboard (GWB) finishes, and roof plans with equipment placement details. The architectural drawings are dated October 28, 2026, and sealed bids for this project were to be received by the City of Carmel's Board of Public Works and Safety through their e-Procurement Portal at https://procurement.opengov.com/portal/carmelin, with a bid deadline of 10:00 am on Wednesday, December 16, 2026.
The scope of work encompasses extensive MEP (mechanical, electrical, plumbing) coordination with demolition of existing ceiling systems, wall modifications, floor slab cutting, and roof penetrations as required for new system installation. The contractor is responsible for field verification of all existing conditions, protection of surfaces to remain, temporary dust control, and coordination with mechanical, electrical, and plumbing drawings for penetration locations. The project includes reinstallation of existing ceiling grids and equipment with matching finishes, patching and repair of affected surfaces, and compliance with fire-rating requirements and applicable building codes. Specific finish standards require all gypsum wallboard to be 5/8" Type X unless noted otherwise, ceilings at 9'-0" AFF standard height with noted exceptions, and all exposed ductwork and piping to be painted with colors selected by the architect. The architectural drawings serve as the reference documents for detailed construction specifications and coordination with the structural, mechanical, electrical, and plumbing design series.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ABBREVIATIONS
A/E
ADA
ARCHITECT/ENGINEER
AMERICANS WITH DISABILITIES ACT
ADD
ADJ
ADDENDUM
ADJACENT
ADMIN
AFF
ADMINISTRATION
ABOVE FINISHED FLOOR
ALUM
APPROX
ALUMINUM
APPROXIMATE
APC
APT
ACOUSTICAL PANEL CEILING
APARTMENT
ARCH
ASSN
ARCHITECT
ASSOCIATION
ASTM
A/V
AMERICAN SOCIETY FOR TESTING AND MATERIALS
AUDIO/VISUAL
AVG
AWI
AVERAGE
ARCHITECTURAL WOODWORKING INSTITUTE
BD
BITUM
BOARD
BITUMINOUS
BLDG
BLKHD
BUILDING
BOT
BSMT
BOTTOM
BASEMENT
BULKHEAD
CAB
CB
CABINET
CHALK BOARD
CD
CD
CONSTRUCTION DOCUMENTS
CONTRACT DOCUMENTS
CIP
CJ
CAST-IN-PLACE
CONTROL JOINT
CL
CLG
CENTER LINE
CEILING
CLO
CLR
CLOSET
CLEAR
CMU
COL
CONCRETE MASONRY UNIT
COLUMN
CONC
CONF
CONCRETE
CONFERENCE
CONST
COORD
CONSTRUCTION
COORDINATE
CORR
CPT
CORRIDOR
CARPET
CSI
CTR
CONSTRUCTION SPECIFICATIONS INSTITUTE
CENTER
CU FT
CU IN
CUBIC FEET
CUBIC INCH
CUST
CW
CUSTODIAN
CURTAINWALL
DBL
DEFS
DOUBLE
DIRECT-APPLIED FINISH SYSTEM
DEG
DEMO
DEGREE
DEMOLITION
DEPT
DET
DEPARTMENT
DETAIL
DF
DH
DRINKING FOUNTAIN
DOUBLE HUNG (DOOR, WINDOW)
DIA
DIAG
DIAMETER
DIAGONAL
DIM
DISP
DIMENSION
DISPENSER
DIV
DN
DIVISION
DOWN
DS
DWG
DOWN SPOUT
DRAWING
EA EACH
EC
EIFS
ELECTRICAL CONTRACTOR
EXTERIOR INSULATION AND FINISH SYSTEM
EJ
EL/ELEV
EXPANSION JOINT
ELEVATION
ELEC
ELEV
ELECTRIC
ELEVATOR
EOS
EPDM
EDGE OF SLAB
ETHYLENE PROPYLENE DIENE MONOMER
EQ
EQUIP
EQUAL
EQUIPMENT
EST
ETC
ESTIMATE
ET CETERA
EXIST EXISTING
FD
FE
FLOOR DRAIN
FIRE EXTINGUISHER
FEC
FIN
FIRE EXTINGUISHER CABINET
FINISH
FIN FLR
FIN GR
FINISH FLOOR
FINISH GRADE
FIXT
FLASH
FIXTURE
FLASHING
FLR
FR
FLOOR
FIRE RESISTANT
FRC
FRG
FIBER REINFORCED CONCRETE
FIBER REINFORCED GYPSUM
FRP
FRZ
FIBERGLASS REINFORCED PLASTIC
FREEZER
FT
FTG
FEET, FOOT
FOOTING
FURG FURRING
FURN
FWC
FURNITURE
FABRIC WALL COVERING
GA
GAL
GAUGE
GALLON
GALV
GC
GALVANIZED
GENERAL CONTRACTOR
GFRC
GFRG
GLASS-FIBER-REINFORCED CONCRETE
GLASS-FIBER-REINFORCED GYPSUM
GFRP GLASS-FIBER-REINFORCED PLASTER
GL BLK
GLU LAM
GLASS BLOCK
GLUE LAMINATED WOOD
GOVT
GWB
GOVERNMENT
GYPSUM WALLBOARD
HAZ
HAZ MAT
HAZARD
HAZARDOUS MATERIALS
HDBD
HDW
HEAVY DUTY HARDBOARD
HARDWARE
HM HOLLOW METAL
HORIZ
HR
HORIZONTAL
HOUR
HT
HVAC
HEIGHT
HEATING, VENTILATION, AND AIR CONDITIONING
IBC INTERNATIONAL BUILDING CODE
ID INSIDE DIAMETER
IN
INSTR
INCH/ INCHES
INSTRUMENT
INSUL
INT
INSULATION, E, (ED)
INTERIOR
JAN JANITOR
KD KNOCK DOWN
KIT
KO
KITCHEN
KNOCKOUT
LAM
LG
LAMINATE
LAMINATED GLASS
LAV
LED
LAVATORY
LIGHT EMITTING DIODE
LF LINEAR FEET (FOOT)
LKR RM
LRG
LOCKER ROOM
LARGE
LT
LT GA
LIGHT
LIGHT GAUGE
MAINT
MAN
MAINTENANCE
MANUAL
MATL
MAX
MATERIAL
MAXIMUM
MB
MC
MARKER BOARD
MECHANICAL CONTRACTOR
MDO
MECH
MEDIUM DENSITY OVERLAY
MECHANICAL
MED
MEMB
MEDIUM
MEMBRANE
MEP
MEZZ
MECHANICAL, ELECTRICAL, PLUMBING
MEZZANINE
MFD
MFG
MANUFACTURED
MANUFACTURING
MFR
MGT
MANUFACTURER
MANAGEMENT
MIN
MISC
MINIMUM
MISCELLANEOUS
ML
MO
METAL LATH
MASONRY OPENING
MT
MTD
MOUNT
MOUNTED
MTG
MTL
MOUNTING
METAL
MULL MULLION
NA
NIC
NOT APPLICABLE
NOT IN CONTRACT
NO
NOM
NUMBER
NOMINAL
NTS NOT TO SCALE
O/O
OC
OUT TO OUT
ON CENTER
OD
OPG
OUTSIDE DIAMETER
OPENING
OPP
ORIG
OPPOSITE
ORIGINAL
OSHA OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION
PART
PBD
PARTIAL
PARTICLEBOARD
PERF
PKG
PERFORATED
PACKAGE
PLAS LAM
PLYWD
PLASTIC LAMINATE
PLYWOOD
PNL
PORC
PANEL
PORCELAIN
PR
PREFAB
PAIR
PREFABRICATED
PREFIN
PREP
PREFINISH
PREPARATION
PROJ
PT
PROJECT
PAINT
R
RCP
RADIUS
REFLECTED CEILING PLAN
RD
REBAR
ROOF DRAIN
REINFORCING STEEL BARS
RECPT
REF
RECEPTACLE
REFERENCE
REF
REINF
REFRIGERATOR
REINFORCED
REQD
REST
REQUIRED
RESTROOM
RM
RO
ROOM
ROUGH OPENING
RTG
RTU
RATING
ROOF TOP UNIT
SCHED
SCHEM
SCHEDULE
SCHEMATIC
SCWD
SECT
SOLID CORE WOOD DOOR
SECTION
SF
SHR
SQUARE FOOT (FEET)
SHOWER
SHT
SIM
SHEET
SIMILAR
SM
SPEC
SMALL
SPECIFICATION
SPKLR
SQ
SPRINKLER
SQUARE
SQ YD
SS
SQUARE YARD
STAINLESS STEEL
ST
STD
STREET
STANDARD
STL
STOR
STEEL
STORAGE
STRUCT
SURR
STRUCTURAL
SURROUND
SUSP SUSPEND
SUSP CLG SUSPENDED CEILING
SV
SVC
SHEET VINYL
SERVICE
SYS SYSTEM
T&G
T/O
TONGUE AND GROOVE
TOP OF
TB
TD
TACK BOARD
TOWEL DISPENSER
TECH
TEMP
TECHNICAL
TEMPORARY
TFF
TG
TOP OF FINISHED FLOOR
TEMPERED GLASS
THK THICKNESS
THRU THROUGH
TI
TOS
TAPERED INSULATION
TOP OF STEEL
TOM TOP OF MASONRY
TRANS TRANSOM
TYP TYPICAL
UL UNDERWRITERS LABORATORIES
UNO UNLESS NOTED OTHERWISE
UPS UNINTERRUPTIBLE POWER SUPPLY
UTIL UTILITY
VAR
VB
VARIES
VINYL BASE
VCT
VEH
VINYL COMPOSITION TILE
VEHICLE
VERT VERTICAL
VEST VESTIBULE
VIF
VOL
VERIFY IN FIELD
VOLUME
VR VAPOR RETARDER
VWC VINYL WALL COVERING
VWF VINYL WALL FABRIC
W/ WITH
W/O
WC
WITHOUT
WALL COVERING
WD WOOD
WP WORKING POINT
WT WEIGHT
CONCRETE MASONRY UNIT
FACE BRICK
EARTH
CONCRETE
PLYWOOD
METAL/STEEL
FINISHED WOOD TRIM
WOOD BLOCKING
WOOD SHIM
INSULATION (LOOSE OR BATT.)
INSULATION (RIGID) GYPSUM BOARD / PLASTER
MATERIAL SYMBOLS
TITLE MARK
SECTION MARK
ELEVATION MARK
CUT LINE
WALL DESIGNATION WINDOW NUMBER
ROOM TAG
View Name
1/8" = 1'-0"
1t W22
ROOM NAME
404B
REFERENCE SYMBOLS
REVISION TAG
A101
SIM
A-201
1 Ref
R ef
R ef
1 Ref
SHEET REFERENCE
DETAIL REFERENCE
DOOR NUMBER
DOOR LABEL
DOOR NUMBER HARDWARE
SET
PANEL TYPE
m in
FG
H M
A
H
M
KEYNOTE LABEL
00 00 00.B9
SPECIFICATION
REFERENCE
UNIQUE
IDENTIFIER
(NOT A
REFERENCE)
UNIT MATCHLINE
UNIT A
UNIT B
DETAIL MARK
A101
SIM
COLUMN DESIGNATION
FB
FB
DATUM POINT NORTH ARROWN
A. CONTRACTOR SHALL FIELD-VERIFY ALL EXISTING CONDITIONS, DIMENSIONS,
AND ARRANGEMENTS.
B. CONTRACTOR IS RESPONSIBLE FOR PROTECTION OF ALL EXISTING SURFACES,
MATERIALS, AND COMPONENTS TO REMAIN OR BE RELOCATED. DAMAGE TO
THESE RESULTING FROM PERFORMANCE OF WORK SHALL BE REPAIRED BY
CONTRACTOR TO SATISFACTION OF OWNER AND ARCHITECT AT NO
ADDITIONAL EXPENSE TO OWNER.
C. CONTRACTOR SHALL PROVIDE TEMPORARY DUST PROTECTION AS REQUIRED
TO PREVENT CONSTRUCTION DEBRIS AND DUST FROM MIGRATING OUT OF
PROJECT AREA. OWNER/ARCHITECT SHALL CONFIRM ALL DUST PREVENTION
MEASURES/LOCATIONS AND SHALL DETERMINE CHANGES TO THESE
MEASURES.
D. ALL EXISTING EQUIPMENT AND FIXTURES SHALL REMAIN PROPERTY OF OWNER.
ALL REUSABLE ITEMS SALVAGED DURING DEMOLITION OPERATIONS SHALL BE
RETAINED FOR OWNER'S INSPECTION. ONLY ITEMS SO INSPECTED AND
REJECTED BY OWNER SHALL BE DISPOSED. ALL OTHER SUCH ITEMS SHALL BE
TURNED OVER TO OWNER FOR DISPOSITION.
E. ALL EXISTING SURFACES LOCATED ADJACENT TO, OR EXPOSED BY DEMOLITION
WORK AND SCHEDULED TO RECEIVE NEW CONSTRUCTION SHALL BE PATCHED
AND REPAIRED AS REQUIRED TO CLEANLY RECEIVE NEW WORK.
F. ALL EXISTING SURFACES LOCATED ADJACENT TO, OR EXPOSED BY DEMOLITION
WORK AND SCHEDULED TO REMAIN EXPOSED AFTER COMPLETION OF NEW
CONST. SHALL BE REPAIRED AND PATCHED AS REQUIRED TO RECEIVE NEW
FINISHES.
G. OWNER WILL BE RESPONSIBLE FOR REMOVAL/REARRANGEMENT OF ALL
EXISTING LOOSE FURNISHINGS DURING CONSTRUCTION, UNLESS NOTED
OTHERWISE.
H. REFER TO MECH./ELEC./PLUMBING DRAWINGS FOR ADDITIONAL PATCHING AND
PREPARATION WORK RELATED TO M.E.P. DEMOLITION ITEMS.
I. EXISTING SLEEVES, HOLES, AND OTHER PENETRATIONS OR NEW DAMAGE OF
EXISTING BUILDING STRUCTURE ABOVE GRADE EXPOSED BY DEMOLITION AND
REMOVAL OF PIPING, APPURTENANCES, EQUIPMENT SHALL BE PATCHED AND
REPAIRED AS PART OF THE WORK. MAINTAIN FIRE RATINGS OF ALL AND
ADJACENT CONSTRUCTION AFFECTED.
J. CAP ALL PIPING TO REMAIN OR ABANDONED IN ACCORDANCE WITH
REQUIREMENTS OF AUTHORITY HAVING JURISDICTION AND IN ACCORDANCE
WITH ALL LOCAL AND STATE PLUMBING AND HEALTH CODES. UTILIZE ONLY PRE-
MANUFACTURED AND APPROVED FITTINGS TO CAP EXISTING PIPING.
K. EACH CONTRACTOR IS RESPONSIBLE FOR ALL DEMOLITION WORK REQUIRED
OR NOTED FOR INSTALLATION OF NEW WORK. DEMOLITION MAY INCLUDE
ASSOCIATED DISTRIBUTION SYSTEMS, APPURTENANCES, EQUIPMENT
SUPPORTING CONTROLS, AND MISCELLANEOUS SUPPORTS, UNLESS NOTED
OTHERWISE.
L. COORDINATE ALL DEMOLITION WITH PROJECT SEQUENCING AS DIRECTED BY
GENERAL CONTRACTOR OR CONSTRUCTION MANAGER.
GENERAL DEMOLITION NOTES
A. ALL DIMENSIONS SHOWN ARE TO FACE OF STUD OR MASONRY, UNLESS
NOTED OTHERWISE. DIMENSIONS DESIGNATED AS "CLR OR "CLEAR" INDICATE
A CLEAR DIMENSION FROM FACE OF FINISH TO FACE OF FINISH. DIMENSIONS
OF EXTERIOR WALLS ARE TO OUTSIDE EDGE OF FOUNDATION.
B. ALL OPENINGS FOR MECHANICAL, PLUMBING, FIRE PROTECTION AND
ELECTRICAL SHALL BE FIRE STOPPED AT EACH FLOOR PENETRATION.
C. PROVIDE BRACING AND BLOCKING AS REQUIRED IN WALLS SUPPORTING
CASEWORK, TACKBOARDS, MARKERBOARDS, AND RESTROOM ACCESSORIES.
D. SEAL ALL JOINTS BETWEEN DISSIMILAR MATERIALS.
E. ALL GYPSUM WALLBOARD IS 5/8" TYPE "X", UNLESS NOTED OTHERWISE.
F. WHERE NEW FLOORS MEET EXISTING FLOORS, A SMOOTH, STRAIGHT, AND
FLUSH TRANSITION SHALL BE CONSTRUCTED. VERIFY IN FIELD EXISTING
FLOOR ELEVATIONS AND CONDITIONS WHERE A NEW FLOOR SHALL BE
CONSTRUCTED ADJACENT. TRIM AND PATCH EXISTING FLOOR AS REQUIRED
TO ACHIEVE DESIRED TRANSITION.
G. HATCHING WITHIN WALLS SHOWN IN PLANS AND SECTIONS INDICATES NEW
CONSTRUCTION.
GENERAL PLAN NOTES
A. ALL CEILINGS ARE AT 9'-0" AFF, UNLESS NOTED OTHERWISE.
B. ALL BULKHEADS ARE AT 8'-10" AFF, UNLESS NOTED OTHERWISE.
C. ALL GRIDS ARE CENTERED IN ROOMS, UNLESS NOTED OTHERWISE.
D. ALL EXPOSED DUCTWORK, PIPING ETC. SHALL BE PAINTED. COLOR SELECTED
BY ARCHITECT.
E. LOCATE SPRINKLER HEADS IN CENTER OF CEILING PANEL - WHERE
APPLICABLE.
GENERAL REFLECTED CEILING
PLAN NOTES
REFLECTED CEILING PLAN
LEGEND
APC-1
2' X 2' Acoustical Panel Ceiling (09 51 13)
APC-3
2' X 2' Humidity Resistant Acoustical Panel Ceiling (09 51 13)
GWB
5/8" GWB on Grid Suspension System (09 22 16)
Walls to Deck
Light Fixture (Reference E-Series Dwgs)
Return Air (Reference M-Series Dwgs)
Supply Air (Reference M-Series Dwgs)
Exit Light (Reference E-Series Dwgs)
Recessed Light Fixture Suspended Fixture in Areas with Exposed Ceilings (Reference E-Series Dwgs)
S
SOUND SYSTEM SPEAKER
(REFERENCE E-SERIES/T-
SERIES DWGS)
APC-2
2' X 2' Acoustical Panel Ceiling (09 51 13)
A. WHERE UTILIZED, TAPERED INSULATION SHALL BE INSTALLED TO ACHIEVE
POSITIVE DRAINAGE WITH A MINIMUM RESULTANT SLOPE OF 1/4" PER FOOT,
UNLESS NOTED OTHERWISE.
B. LOW SLOPE ROOF AREAS SHALL HAVE A MINIMUM OF 4" RIGID INSULATION
OVER METAL ROOF DECK. SADDLES, CRICKETS, AND SLOPE PORTIONS OF
FLAT ROOF DECK SHALL BE FORMED BY TAPERED INSULATION. AREAS
WHERE TAPERED INSULATION IS ANTICIPATED HAVE BEEN INDICATED, BUT
SHALL NOT BE CONSIDERED ALL INCLUSIVE. IT IS CONTRACTOR'S
RESPONSIBILITY TO PROVIDE SLOPED SURFACES TO ACHIEVE PROPER
DRAINAGE.
C. ROOF PENETRATIONS AND EQUIPMENT SHOWN SHALL NOT BE CONSIDERED
ALL INCLUSIVE. COORDINATE WITH MECHANICAL, PLUMBING AND ELECTRICAL
DOCUMENTS TO CONFIRM PENETRATIONS AND EQUIPMENT LOCATIONS.
FLASH ALL ROOF PENETRATIONS IN ACCORDANCE WITH ROOFING
MANUFACTURER'S RECOMMENDATIONS. PROVIDE CRICKETS TO ALLOW FOR
PROPER DRAINAGE AROUND UNITS.
GENERAL ROOF PLAN NOTES
COMPONENT SYMBOLS
EXISTING CONSTRUCTION/DOOR
TO REMAIN
ITEMS TO BE DEMOLISHED
(DEMOLITION PLAN)
NEW DOOR
CLEARANCE
WHEELCHAIR CLEARANCE RADIUS
ADA
09 29 00.B7 - INT GWB, 5/8" TYPE X
09 22 16.C6 - INT STEEL STUD
FRAMING, 3-5/8" @ 16" O.C.
M
IN
09 51 13.A2 - CEILING FINISH, REF
ARCHITECTURAL CEILING PLANS
09 22 16.C13 - DEFLECTION TRACK
SECURE FRAMING TO DECK/STRUCTURE
ABOVE
N
123456
A
B
C
D
E
123456
A
B
C
D
E
Project No.
Project Date
Produced
These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this
Project and are not to be used on any other Project or Work without prior written permission from the Architect.
KEY PLAN
/2
/2
:3
:5
A M
C
R e v it L o c a l\
-0
.4
H
B ld g
A
\2
-0
.4
H B ld g
A tp h a n .r v t
2026-028.44H
10.28.2026
ARCHITECTURAL
GENERAL NOTES AND
ABBREVIATIONS
A-001
TP
CITY OF CARMEL
FIRE STATION #44
HVAC
REPLACEMENT
-0
.4
H
C
IT
Y
O F
C A
R M
E L F
IR
E
S T
A T
IO
N
H
V A
C R
E P
L A
C E
M E
N T
5032 E MAIN ST
CARMEL, IN 46033
A -0
A
R C
H
IT
E C
T U
R A
L G
E N
E R
A L N
O T
E S
A N
D A
B B
R E
V
IA
T
IO
N S
1 1/2" = 1'-0" 1A
S4-C' WALL TYPE
# Revision Date
UP
DN
UP
DN
DN
UP
A B C D E F GA.1 D.6
FITNESS ROOM
CAPTAIN'S OFFICE
OFFICE STORAGE
OFFICE / WATCHROOM
VESTIBULE
GEAR ROOM
ADA RR
RR
AIR COMPRESSOR
EMS STORAGE
RISER
RR
CUSTODIAL
TOOL ROOM
APPARATUS BAY
ELEC
CORRIDOR
STOR.
STAIR 1
ST 1-1
STAIR 2.1
ST 2-1
10 9
8' - 0"
10' - 0"
A B C D E F GA.1 D.6
DORM
220A
DORM
219A
DORM
218A
DORM
217A
DORM
216A
BATH
216B
BATH
217B
LOCKER
LOCKER
BATH
218B
BATH
219B
LOCKER
LOCKER
BATH
220B
LOCKER
PANTRY
PANTRY
PANTRY
JANITOR
SUPPLY CLOSET
LOCKER
DORM
215A
BATH
215B
MECH.
STORAGE
BATH
214B
DORM
214A
DORM
213A
LOCKER
BATH
213B
LAUNDRY
KITCHEN
DINING
DAY ROOM
LOCKER
CORRIDOR
STAIR 1
ST 1-2
STAIR 2
ST 2-2
1 1 1 1 1
33333
3 3
3 2 2
1 13 3
RR
RR
PLANNING
OFFICE
STORAGE
006A
EMERGENCY OPERATIONS
OFFICE
MDF
003A
STAIR 1
ST-1-0 3
OFFICE
1 1
OFFICE
A. CONTRACTOR SHALL FIELD-VERIFY ALL EXISTING CONDITIONS, DIMENSIONS,
AND ARRANGEMENTS.
B. CONTRACTOR IS RESPONSIBLE FOR PROTECTION OF ALL EXISTING SURFACES,
MATERIALS, AND COMPONENTS TO REMAIN OR BE RELOCATED. DAMAGE TO
THESE RESULTING FROM PERFORMANCE OF WORK SHALL BE REPAIRED BY
CONTRACTOR TO SATISFACTION OF OWNER AND ARCHITECT AT NO
ADDITIONAL EXPENSE TO OWNER.
C. CONTRACTOR SHALL PROVIDE TEMPORARY DUST PROTECTION AS REQUIRED
TO PREVENT CONSTRUCTION DEBRIS AND DUST FROM MIGRATING OUT OF
PROJECT AREA. OWNER/ARCHITECT SHALL CONFIRM ALL DUST PREVENTION
MEASURES/LOCATIONS AND SHALL DETERMINE CHANGES TO THESE
MEASURES.
D. ALL EXISTING EQUIPMENT AND FIXTURES SHALL REMAIN PROPERTY OF OWNER.
ALL REUSABLE ITEMS SALVAGED DURING DEMOLITION OPERATIONS SHALL BE
RETAINED FOR OWNER'S INSPECTION. ONLY ITEMS SO INSPECTED AND
REJECTED BY OWNER SHALL BE DISPOSED. ALL OTHER SUCH ITEMS SHALL BE
TURNED OVER TO OWNER FOR DISPOSITION.
E. ALL EXISTING SURFACES LOCATED ADJACENT TO, OR EXPOSED BY DEMOLITION
WORK AND SCHEDULED TO RECEIVE NEW CONSTRUCTION SHALL BE PATCHED
AND REPAIRED AS REQUIRED TO CLEANLY RECEIVE NEW WORK.
F. ALL EXISTING SURFACES LOCATED ADJACENT TO, OR EXPOSED BY DEMOLITION
WORK AND SCHEDULED TO REMAIN EXPOSED AFTER COMPLETION OF NEW
CONST. SHALL BE REPAIRED AND PATCHED AS REQUIRED TO RECEIVE NEW
FINISHES.
G. OWNER WILL BE RESPONSIBLE FOR REMOVAL/REARRANGEMENT OF ALL
EXISTING LOOSE FURNISHINGS DURING CONSTRUCTION, UNLESS NOTED
OTHERWISE.
H. REFER TO MECH./ELEC./PLUMBING DRAWINGS FOR ADDITIONAL PATCHING AND
PREPARATION WORK RELATED TO M.E.P. DEMOLITION ITEMS.
I. EXISTING SLEEVES, HOLES, AND OTHER PENETRATIONS OR NEW DAMAGE OF
EXISTING BUILDING STRUCTURE ABOVE GRADE EXPOSED BY DEMOLITION AND
REMOVAL OF PIPING, APPURTENANCES, EQUIPMENT SHALL BE PATCHED AND
REPAIRED AS PART OF THE WORK. MAINTAIN FIRE RATINGS OF ALL AND
ADJACENT CONSTRUCTION AFFECTED.
J. CAP ALL PIPING TO REMAIN OR ABANDONED IN ACCORDANCE WITH
REQUIREMENTS OF AUTHORITY HAVING JURISDICTION AND IN ACCORDANCE
WITH ALL LOCAL AND STATE PLUMBING AND HEALTH CODES. UTILIZE ONLY PRE-
MANUFACTURED AND APPROVED FITTINGS TO CAP EXISTING PIPING.
K. EACH CONTRACTOR IS RESPONSIBLE FOR ALL DEMOLITION WORK REQUIRED
OR NOTED FOR INSTALLATION OF NEW WORK. DEMOLITION MAY INCLUDE
ASSOCIATED DISTRIBUTION SYSTEMS, APPURTENANCES, EQUIPMENT
SUPPORTING CONTROLS, AND MISCELLANEOUS SUPPORTS, UNLESS NOTED
OTHERWISE.
L. COORDINATE ALL DEMOLITION WITH PROJECT SEQUENCING AS DIRECTED BY
GENERAL CONTRACTOR OR CONSTRUCTION MANAGER.
GENERAL DEMOLITION NOTES
N
123456
A
B
C
D
E
123456
A
B
C
D
E
Project No.
Project Date
Produced
These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this
Project and are not to be used on any other Project or Work without prior written permission from the Architect.
KEY PLAN
/2
/2
:3
:5
A M
C
R e v it L o c a l\
-0
.4
H
B ld g
A
\2
-0
.4
H B ld g
A tp h a n .r v t
2026-028.44H
10.28.2026
OVERALL DEMOLITION
FIRST PLAN
AD101
TP
CITY OF CARMEL
FIRE STATION #44
HVAC
REPLACEMENT
-0
.4
H
C
IT
Y
O F
C A
R M
E L F
IR
E
S T
A T
IO
N
H
V A
C R
E P
L A
C E
M E
N T
5032 E MAIN ST
CARMEL, IN 46033
A D
O
V E
R A
L L D
E M
O L
IT
IO
N
F
IR
S T
P L A
N
1/8" = 1'-0" 2A
DEMOLITION FLOOR PLAN - FIRST FLOOR
1/8" = 1'-0" 2C
DEMOLITION FLOOR PLAN - SECOND FLOOR
1/8" = 1'-0" 4A
DEMOLITION FLOOR PLAN - BASEMENT
DEMOLITION PLAN NOTES
REFER TO A-001 FOR GENERAL NOTES. NOT ALL NOTES APPLY TO EVERY SHEET.
# NOTE
1 REMOVE EXISTING CEILING PADS IN THEIR ENTIRETY. TAKE DOWN CEILING GRIDS
AS REQUIRED FOR MEP WORK. PROTECT EXISTING GRIDS FOR REINSTALLATION.
CONTRACTOR TO REPLACE DAMAGED CEILING GRIDS. MATCH EXISTING. VIF.
2 CUT EXISTING GYPSUM CEILING AS REQUIRED FOR MEP WORK. PATCH, REPAIR,
AND FINISH TO MATCH EXISTING.
3 REMOVE EXISTING SUSPENDED LAY-IN PANEL CEILING SYSTEM IN ITS ENTIRETY
INCLUDING, BUT NOT LIMITED TO THE CEILING PADS, GRID, SUSPENSION WIRES,
AND ALL RELATED ANCHORS. PATCH AND REPAIR EXISTING SURFACES TO REMAIN
AND PREP FOR NEW CONSTRUCTION/FINISH.
4 REMOVE EXISTING GYPSUM BOARD CEILING SYSTEM IN ITS ENTIRETY INCLUDING,
BUT NOT LIMITED TO THE GYPSUM BOARD, SUSPENDED FRAMING AND ALL
RELATED ANCHORS/FASTENERS. PATCH AND REPAIR EXISTING SURFACES TO
REMAIN AND PREP FOR NEW CONSTRUCTION/FINISH.
5 REMOVE EXISTING INTERIOR WALL CONSTRUCTION IN ITS ENTIRETY TO LIMITS
INDICATED INCLUDING, BUT NOT LIMITED TO DOORS, FRAMES, WINDOWS AND ALL
MISCELLANEOUS FRAMING. FIELD VERIFY ALL EXISTING WALL CONSTRUCTION
PRIOR TO DEMOLITION. REFER TO ARCHITECTURAL AND INTERIOR FLOOR PLANS
FOR FINISH CONDITIONS AND DIMENSIONS. PATCH AND REPAIR EXISTING
ADJACENT SURFACES TO REMAIN AND PREP FOR NEW CONSTRUCITON.
6 EXISTING BULKHEAD TO REMAIN, PATCH AND REPAIR AS REQUIRED. MATCH
EXISTING.
7 CUT EXISTING ROOF MEMBRANE, PROTECTION BOARD, INSULATION, AND ROOF
DECK AS REQUIRED FOR NEW MEP PENETRATIONS. REF. MEP SERIES DRAWINGS
FOR PENETRATION LOCATIONS. PATCH AND REPAIR AS REQUIRED AND PREP FOR
NEW WORK. VIF EXISTING CONDITION BEFORE CUTTING.
8 SAW CUT EXISTING CONCRETE FLOOR SLAB IN ITS ENTIRETY TO LIMITS INDICATED
FOR MEP WORK. REFERENCE MEP-SERIES AND S-SERIES DRAWINGS FOR
ADDITIONAL INFORMATION. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
EXISTING BUILDING CONDITIONS IN THE FIELD. PATCH AND REPAIR SLAB-ON-GRADE
CONCRETE FLOOR TO MATCH EXISTING, VIF.
9 REMOVE AND SALVAGE EXISTING SHELVES AND SUPPORT BRACKETS IN ITS
ENTIRETY AND ALL RELATED ANCHORS AND SEALANTS. PATCH AND REPAIR
EXISTING WALL SURFACE TO REMAIN AND PREP FOR NEW CONSTRUCTION/FINISH.
MODIFY SHELVES AS REQUIRED FOR REINSTALLATION. COORDINATE WITH OWNER
FOR LOCATION.
10 REMOVE EXISTING CARPET FLOOR FINISH IN ITS ENTIRETY INCLUDING, BUT NOT
LIMITED TO THE CARPET, ADHESIVES/TACK STRIPS, TRANSITION STRIPS AND ALL
ASSOCIATED WALL BASE TO THE LIMITS INDICATED. PATCH AND REPAIR EXISTING
SURFACES TO REMAIN AND PREP FOR NEW CONSTRUCTION/FINISH.
11 CUT EXISTING GYPSUM CEILING ABOVE CEILING GRID AS REQUIRED FOR MEP
WORK. PATCH, REPAIR, AND FINISH TO MATCH EXISTING.
12 TAKE DOWN CEILING GRIDS AND PADS AS REQUIRED FOR MEP WORK. PROTECT
EXISTING CEILING PADS AND GRIDS FOR REINSTALLATION. CONTRACTOR TO
REPLACE DAMAGED CEILING TILES AND GRIDS. MATCH EXISTING. VIF. # Revision Date
DN
UP
DN
DN
OFFICE
EMERGENCY OPERATIONS
PLANNING
OFFICE
STORAGE
006A
RR
RR
STAIR 1
ST-1-0
MDF
003A
OFFICE
CUSTODIAL
004A
ELEV.
EV-1-0
OFFICE
A B C D E F GA.1 D.6
FITNESS ROOM
CAPTAIN'S OFFICE
OFFICE STORAGE
OFFICE / WATCHROOM
VESTIBULE
GEAR ROOM
ADA RR
RR
AIR COMPRESSOR
EMS STORAGE
RISER
RR
CUSTODIAL
TOOL ROOM
APPARATUS BAY
ELEC
CORRIDOR
STOR.
STAIR 1
ST 1-1
STAIR 2.1
ST 2-1
S4-C'
M A
T C
H E
X
IS
T
IN
G V
IF
/8
ELEV.
EV-1-1
3' - 0"
S -C
1 2
1 2
A B C D E F GA.1 D.6
DORM
220A
DORM
219A
DORM
218A
DORM
217A
DORM
216A
BATH
216B
BATH
217B
LOCKER
LOCKER
BATH
218B
BATH
219B
LOCKER
LOCKER
BATH
220B
LOCKER
PANTRY
PANTRY
PANTRY
JANITOR
SUPPLY CLOSET
LOCKER
DORM
215A
BATH
215B
MECH.
STORAGE
BATH
214B
DORM
214A
DORM
213A
LOCKER
BATH
213B
LAUNDRY
KITCHEN
DINING
DAY ROOM
LOCKER
CORRIDOR
STAIR 1
ST 1-2
STAIR 2
ST 2-2
5A
AR100
S -C
2' - 4"
A. ALL DIMENSIONS SHOWN ARE TO FACE OF STUD OR MASONRY, UNLESS
NOTED OTHERWISE. DIMENSIONS DESIGNATED AS "CLR OR "CLEAR" INDICATE
A CLEAR DIMENSION FROM FACE OF FINISH TO FACE OF FINISH. DIMENSIONS
OF EXTERIOR WALLS ARE TO OUTSIDE EDGE OF FOUNDATION.
B. ALL OPENINGS FOR MECHANICAL, PLUMBING, FIRE PROTECTION AND
ELECTRICAL SHALL BE FIRE STOPPED AT EACH FLOOR PENETRATION.
C. PROVIDE BRACING AND BLOCKING AS REQUIRED IN WALLS SUPPORTING
CASEWORK, TACKBOARDS, MARKERBOARDS, AND RESTROOM ACCESSORIES.
D. SEAL ALL JOINTS BETWEEN DISSIMILAR MATERIALS.
E. ALL GYPSUM WALLBOARD IS 5/8" TYPE "X", UNLESS NOTED OTHERWISE.
F. WHERE NEW FLOORS MEET EXISTING FLOORS, A SMOOTH, STRAIGHT, AND
FLUSH TRANSITION SHALL BE CONSTRUCTED. VERIFY IN FIELD EXISTING
FLOOR ELEVATIONS AND CONDITIONS WHERE A NEW FLOOR SHALL BE
CONSTRUCTED ADJACENT. TRIM AND PATCH EXISTING FLOOR AS REQUIRED
TO ACHIEVE DESIRED TRANSITION.
G. HATCHING WITHIN WALLS SHOWN IN PLANS AND SECTIONS INDICATES NEW
CONSTRUCTION.
GENERAL PLAN NOTES
N
123456
A
B
C
D
E
123456
A
B
C
D
E
Project No.
Project Date
Produced
These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this
Project and are not to be used on any other Project or Work without prior written permission from the Architect.
KEY PLAN
/2
/2
:3
:5
A M
C
R e v it L o c a l\
-0
.4
H
B ld g
A
\2
-0
.4
H B ld g
A tp h a n .r v t
2026-028.44H
10.28.2026
OVERALL FLOOR PLANS
AF101
TP
CITY OF CARMEL
FIRE STATION #44
HVAC
REPLACEMENT
-0
.4
H
C
IT
Y
O F
C A
R M
E L F
IR
E
S T
A T
IO
N
H
V A
C R
E P
L A
C E
M E
N T
5032 E MAIN ST
CARMEL, IN 46033
A F
O
V E
R A
L L F
L O
O R
P L A
N S
1/8" = 1'-0" 4A
BASEMENT
1/8" = 1'-0" 2A
FIRST FLOOR
1/8" = 1'-0" 2C
SECOND FLOOR
FLOOR PLAN NOTES
REFER TO A-001 FOR GENERAL NOTES. NOT ALL NOTES APPLY TO EVERY SHEET.
# NOTE
1 MODIFY EXISTING FLOOR AND WALL BASE AS REQUIRED FOR NEW WALL. PROVIDE
NEW WALL BASE FOR NEW WALL. WALL BASE TO MATCH EXISTING.
2 099600.99 - NEW WALL FINISH TO MATCH EXISTING, VIF.
3 NEW SLAB-ON-GRADE INFILL. MATCH EXISTING, VIF. REF. S-SERIES DRAWINGS.
A B C D E F GA.1 D.6
2 2
A.F.F.
APC-1
12' - 0"
A.F.F.
APC-1
10' - 0"
A.F.F.
APC-2
10' - 0"
A.F.F.
APC-1
10' - 0"
A.F.F.
APC-1
10' - 0"
A.F.F.
APC-2
10' - 0"
GEAR ROOM
FITNESS ROOM
ADA RR
RR
CORRIDOR
CAPTAIN'S OFFICE
OFFICE STORAGE
OFFICE / WATCHROOM
VESTIBULE
AIR COMPRESSOR
EMS STORAGE
RISER
RR
CUSTODIAL
TOOL ROOM
ELEC
STAIR 2.1
ST 2-1
APPARATUS BAY
A.F.F.
APC-2
9' - 0"
A.F.F.
APC-1
10' - 0"
A B C D E F GA.1 D.6
RR
RR
PLANNING
OFFICE
STORAGE
006A
EMERGENCY OPERATIONS
OFFICE
MDF
003A
STAIR 1
ST-1-0
OFFICE
A.F.F.
APC-2
9' - 0"
A.F.F.
APC-1
8' - 8"
A.F.F.
APC-1
8' - 8"
4C
AC101
A.F.F.
APC-2
9' - 0"
OFFICE
A.F.F.
APC-1
8' - 8"
A.F.F.
APC-1
8' - 8"
1 1
A B C D E F GA.1 D.6
DORM
220ADORM
219A
DORM
218A
DORM
217A
DORM
216A
BATH
216B
BATH
217B
LOCKER
LOCKER
BATH
218B
BATH
219B
LOCKER
LOCKER
BATH
220B
LOCKER
PANTRY
PANTRY
PANTRY
JANITOR
SUPPLY CLOSET
LOCKER
DORM
215A
BATH
215B
MECH.
STORAGE
BATH
214BDORM
214A
DORM
213A
LOCKER
BATH
213B
LAUNDRY
KITCHEN
DINING
DAY ROOM
LOCKER
CORRIDOR
STAIR 1
ST 1-2
STAIR 2
ST 2-2
2 8
1 1 1 1 1
333 3 3
A.F.F.
APC-1
9' - 0"
A.F.F.
GWB
8' - 10"
A.F.F.
APC-2
9' - 0"
A.F.F.
GWB
8' - 0"
A.F.F.
GWB
10' - 0"
A.F.F.
GWB
10' - 0"
A.F.F.
APC-2
8' - 4"
A.F.F.
APC-2
9' - 0"
A.F.F.
APC-1
9' - 0"A.F.F.
APC-1
9' - 0"A.F.F.
APC-1
9' - 0"A.F.F.
APC-1
9' - 0"
A.F.F.
APC-1
9' - 0"
A.F.F.
APC-1
8' - 0"
A.F.F.
APC-1
9' - 0"
A.F.F.
APC-1
9' - 0"
A.F.F.
APC-3
7' - 8"
A.F.F.
APC-1
9' - 0"
A.F.F.
APC-2
9' - 0"
A.F.F.
APC-2
8' - 4"
A.F.F.
GWB
8' - 0"
7 7 7 7
A.F.F.
APC-1
9' - 0"
A.F.F.
APC-1
9' - 0"
A.F.F.
APC-1
9' - 0"
A.F.F.
APC-2
9' - 0"
A.F.F.
APC-1
9' - 0" A.F.F.
APC-1
9' - 0" A.F.F.
APC-1
9' - 0" A.F.F.
APC-1
9' - 0"
A.F.F.
APC-1
9' - 0"
A.F.F.
APC-1
8' - 0"
A.F.F.
APC-1
9' - 0"
A.F.F.
APC-3
8' - 0"
A.F.F.
APC-1
9' - 0" A.F.F.
APC-1
9' - 0" A.F.F.
APC-1
8' - 0"
1 1
REFLECTED CEILING PLAN
LEGEND
APC-1
2' X 2' Acoustical Panel Ceiling (09 51 13)
APC-3
2' X 2' Humidity Resistant Acoustical Panel Ceiling (09 51 13)
GWB
5/8" GWB on Grid Suspension System (09 22 16)
Walls to Deck
Light Fixture (Reference E-Series Dwgs)
Return Air (Reference M-Series Dwgs)
Supply Air (Reference M-Series Dwgs)
Exit Light (Reference E-Series Dwgs)
Recessed Light Fixture Suspended Fixture in Areas with Exposed Ceilings (Reference E-Series Dwgs)
S
SOUND SYSTEM SPEAKER
(REFERENCE E-SERIES/T-
SERIES DWGS)
APC-2
2' X 2' Acoustical Panel Ceiling (09 51 13)
A. ALL CEILINGS ARE AT 9'-0" AFF, UNLESS NOTED OTHERWISE.
B. ALL BULKHEADS ARE AT 8'-10" AFF, UNLESS NOTED OTHERWISE.
C. ALL GRIDS ARE CENTERED IN ROOMS, UNLESS NOTED OTHERWISE.
D. ALL EXPOSED DUCTWORK, PIPING ETC. SHALL BE PAINTED. COLOR SELECTED
BY ARCHITECT.
E. LOCATE SPRINKLER HEADS IN CENTER OF CEILING PANEL - WHERE
APPLICABLE.
GENERAL REFLECTED CEILING
PLAN NOTES
M
IN
REF. PLANS
M
IN
09 29 00.B7 - INT GWB, 5/8" TYPE X
09 22 16.C6 - INT STEEL STUD
FRAMING, 3-5/8" @ 16" O.C.
09 51 13.A2 - CEILING FINISH, REF
ARCHITECTURAL CEILING PLANS
REF. PLANS
M
IN
V
IF
EXISTING DISPLAY, VIF.
EXISTING WALL
09 51 13.A2 - CEILING FINISH, REF
ARCHITECTURAL CEILING PLANS
N
123456
A
B
C
D
E
123456
A
B
C
D
E
Project No.
Project Date
Produced
These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this
Project and are not to be used on any other Project or Work without prior written permission from the Architect.
KEY PLAN
/2
/2
:3
:0
A M
C
R e v it L o c a l\
-0
.4
H
B ld g
A
\2
-0
.4
H B ld g
A tp h a n .r v t
2026-028.44H
10.28.2026
FIRST FLOOR
REFLECTED CEILING
PLAN
AC101
TP
CITY OF CARMEL
FIRE STATION #44
HVAC
REPLACEMENT
-0
.4
H
C
IT
Y
O F
C A
R M
E L F
IR
E
S T
A T
IO
N
H
V A
C R
E P
L A
C E
M E
N T
5032 E MAIN ST
CARMEL, IN 46033
A C
F
IR
S
T F
L O
O R
R E
F L E
C T
E D
C E
IL
IN
G P
L A
N
1/8" = 1'-0" 2A
FIRST FLOOR(1)
1/8" = 1'-0"
4A
BASEMENT
1/8" = 1'-0" 2C
SECOND FLOOR(1)
REFLECTED CEILING PLAN NOTES
REFER TO A-001 FOR GENERAL NOTES. NOT ALL NOTES APPLY TO EVERY SHEET.
# NOTE
1 REINSTALL EXISTING CEILING GRIDS WITH NEW CEILING PADS. CONTRACTOR TO
REPLACE DAMAGED EXISTING CEILING GRIDS AS REQUIRED. CEILING GRID
REPLACEMENT TO MATCH EXISTING, VIF.
2 PATCH AND REPAIR GYPSUM CEILING AS REQUIRED FROM MEP WORK. FINISH TO
MATCH EXISTING.
3 NEW CEILING GRID AND PADS, MATCH EXISTING HEIGHT AND LOCATION. REINSTALL
CEILING MOUNTED EQUIPMENT/DEVICES/FIXTURES. REF. MEP SERIES DRAWINGS.
4 NEW GWB CEILING, MATCH EXISTING HEIGHT. NEW PAINT/FINISH TO MATCH
EXISTING, VIF. REINSTALL CEILING MOUNTED EQUIPMENT/DEVICES/FIXTURES. REF.
MEP SERIES DRAWINGS
5 PATCH AND REPAIR EXISTING GWB AS REQUIRED FROM MEP WORK.
REPAINT/REFINISH ENTIRE GWB CEILING, MATCH EXISTING. REINSTALL CEILING
MOUNTED EQUIPMENT/DEVICES/FIXTURES. REF. MEP SERIES DRAWINGS
6 SLOPE CEILING GRID AND TILES UP TO BE ABOVE EXISTING WALL MOUNTED
DISPLAY SCREEN.
7 NO CEILING WORK
8 REINSTALL EXISTING CEILING GRID AND PADS, MATCH EXISTING LAYOUT AND
HEIGHT. CONTRACTORS TO REPLACE ANY DAMAGED CEILING GRIDS AND PADS,
MATCH EXISTING. REINSTALL CEILING MOUNTED EQUIPMENT/DEVICES/FIXTURES.
REF. MEP SERIES DRAWINGS.
1 1/2" = 1'-0" 4D
TYPICAL BULKHEAD DETAIL
# Revision Date
3/4" = 1'-0" 4C
SLOPE CEILING
A B C D E F GA.1 D.6
2 5A
AR100
A. WHERE UTILIZED, TAPERED INSULATION SHALL BE INSTALLED TO ACHIEVE
POSITIVE DRAINAGE WITH A MINIMUM RESULTANT SLOPE OF 1/4" PER FOOT,
UNLESS NOTED OTHERWISE.
B. LOW SLOPE ROOF AREAS SHALL HAVE A MINIMUM OF 4" RIGID INSULATION
OVER METAL ROOF DECK. SADDLES, CRICKETS, AND SLOPE PORTIONS OF
FLAT ROOF DECK SHALL BE FORMED BY TAPERED INSULATION. AREAS
WHERE TAPERED INSULATION IS ANTICIPATED HAVE BEEN INDICATED, BUT
SHALL NOT BE CONSIDERED ALL INCLUSIVE. IT IS CONTRACTOR'S
RESPONSIBILITY TO PROVIDE SLOPED SURFACES TO ACHIEVE PROPER
DRAINAGE.
C. ROOF PENETRATIONS AND EQUIPMENT SHOWN SHALL NOT BE CONSIDERED
ALL INCLUSIVE. COORDINATE WITH MECHANICAL, PLUMBING AND ELECTRICAL
DOCUMENTS TO CONFIRM PENETRATIONS AND EQUIPMENT LOCATIONS.
FLASH ALL ROOF PENETRATIONS IN ACCORDANCE WITH ROOFING
MANUFACTURER'S RECOMMENDATIONS. PROVIDE CRICKETS TO ALLOW FOR
PROPER DRAINAGE AROUND UNITS.
GENERAL ROOF PLAN NOTES
SECOND FLOOR
18' - 0"
LOW ROOF FRAMING PLAN
+16'-8"
LOW ROOF FRAMING PLAN
+16'-8"
SECOND FLOOR
18' - 0"
SECOND FLOOR
18' - 0"
10 24 00 - SCREEN WALL
07 53 23 - SQUARE TUBE WRAP FLASHING
AROUND SQUARE/RECTANGULAR STEEL TUBE
PER MANUFACTURER'S RECOMMENDATION TO
TO MAINTAIN EXISTING ROOF WARRANTY.
M
IN
10 24 00 - SUB FRAMING
05 12 00.A1 - STRUCT STEEL, REF
S-SERIES DWGS
EXISTING ROOF, VIF.
N
123456
A
B
C
D
E
123456
A
B
C
D
E
Project No.
Project Date
Produced
These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this
Project and are not to be used on any other Project or Work without prior written permission from the Architect.
KEY PLAN
/2
/2
:3
:0
A M
C
R e v it L o c a l\
-0
.4
H
B ld g
A
\2
-0
.4
H B ld g
A tp h a n .r v t
2026-028.44H
10.28.2026
ROOF PLAN
AR100
TP
CITY OF CARMEL
FIRE STATION #44
HVAC
REPLACEMENT
-0
.4
H
C
IT
Y
O F
C A
R M
E L F
IR
E
S T
A T
IO
N
H
V A
C R
E P
L A
C E
M E
N T
5032 E MAIN ST
CARMEL, IN 46033
A R
R
O O
F P
L A
N
1/8" = 1'-0" 1A
OVERALL ROOF PLAN
ROOF PLAN NOTES
REFER TO A-001 FOR GENERAL NOTES. NOT ALL NOTES APPLY TO EVERY SHEET.
# NOTE
1 ROOF TOP M/E/P/T EQUIPMENT, PROVIDE ROOF CURBS AND MANUFACTURER
STANDARD FLASHING DETAIL. REFERENCE M/E/P/T SERIES DRAWINGS . PROVIDE
TAPERED INSULATION CRICKETS AS REQUIRED AROUND THE EQUIPMNET FOR
POSITIVE DRAINAGE TO DRAINS. INSTALL FLASHING AND CURB PER
MANUFACTURER'S RECOMMENDATION TO MAINTAIN EXISTING ROOF WARRANTY.
2 10 24 00 - CONTINUOUS SCREEN WALL, REF. TO S-SERIES DWGS FOR STRUCTURAL
SUPPORT LOCATIONS. PER MANUFACTURER'S RECOMMENDATION TO MAINTAIN
ROOFING WARRANTY, PROVIDE TPO CONSTRUCTED TUBE WRAPS TO WRAP
AROUND SQUARE/RECTANGULAR STEEL TUBE STRUCTURE.
3 07 53 23 - FLEXIBLE WALKWAY PAD PER MANUFACTURER'S RECOMMENDATION TO
MAINTAIN EXISTING ROOF WARRANTY.
3/4" = 1'-0" 5A
SCREEN WALL SECTION
| A-001 - ARCHITECTURAL GENERAL NOTES AND ABBREVIATIONS |
| AD101 - OVERALL DEMOLITION FIRST PLAN |
| AF101 - OVERALL FLOOR PLANS |
| AC101 - FIRST FLOOR REFLECTED CEILING PLAN |
| AR100 - ROOF PLAN |
File details come from the government source that posted it. Updated .