This solicitation notice seeks full maintenance services for federal facilities in Houston, Beaumont, and Galveston, Texas. The services include operation and maintenance, custodial work, and grounds maintenance at eight buildings totaling over 1.7 million rentable square feet. The facilities support services contract has a start date of May 1, 2021. The North American Industry Classification System code is 561210 for facilities support services, and the small business size standard is $41.5 million. The acquisition is reserved 100% for Service-Disabled Veteran-Owned Small Businesses.
View the file
Other files
Show 40 more
Latest 50 of 54 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
G.T. Mickey Leland Federal Office Building Tenant Guidelines
November 18, 2015 Project No. 02.7017.000
Prepared by Gensler 711 Louisiana Street Suite 300 Houston, TX 77002
PROPERTY OF UNITED STATES GOVERNMENT
COPYING, DISSEMINATION, OR DISTRIBUTION OF THESE SPECIFICATIONS TO UNAUTHORIZED PERSONS IS
PROHIBITED. Do not remove this notice. Properly destroy documents when no longer needed.
Tenant Standards G.T. Mickey Leland Federal Office Building 2 11.18.2015
Tenant Standards G.T. Mickey Leland Federal Office Building 3
TABLE OF CONTENT
INTRODUCTION 7
BUILDING INFORMATION
Overview of ARRA Project
DIVISION 01 – GENERAL REQUIREMENTS SUBGROUP
Sustainable Design Requirements
Commissioning Requirements
Life Safety Review
DIVISION 03 – CONCRETE
Cast In Place Concrete
Precast Concrete
DIVISION 05 – METALS
Decorative Formed Metal
DIVISION 06 – WOOD, PLUMBING & COMPOSITES
Interior Architectural Woodwork
DIVISION 07 – THERMAL AND MOISTURE PROTECTION
Applied Fireproofing
Fire-Resistive Joint Systems
Joint Sealants
Tenant Standards G.T. Mickey Leland Federal Office Building 4
DIVISION 08 – OPENINGS
Hollow Metal Doors and Frames
Aluminum Door and Window Frames
Flush Wood Doors
Access Doors and Frames
Aluminum Entrances and Storefronts
All-Glass Entrances and Storefronts
Glazed Aluminum Curtain Walls-Cassette System
Door Hardware
Glazing
DIVISION 09 – FINISHES
Gypsum Board Partitions
Tiling
Acoustical Panel Ceilings
Stone Flooring
Stone Facing
Base and Accessories
Tile Carpeting
Interior Painting
DIVISION 10 – SPECIALTIES
Signage……………………………………………………………………………………………………………………….… 53
Toilet Compartments
Fire-Protection Specialties
DIVISION 12 – FURNISHINGS
Roller Window Shades
Stone Countertops
Tenant Standards G.T. Mickey Leland Federal Office Building 5
DIVISION 21 – FIRE SUPPRESSION
Fire Suppression System
DIVISION 22 – PLUMBING
Plumbing Overview
General Requirements
Miscellaneous Brass Trim
Plumbing Fixtures
DIVISION 23 – HEATING, VENTILATING AND AIR CONDITIONING
Mechanical Overview
Controls
DIVISION 26 – ELECTRICAL
Electrical Requirements
Lighting Fixtures
DIVISION 27 – COMMUNICATIONS
Communication Requirements
DIVISION 28 – ELECTRONIC SAFETY AND SECURITY
Building Security System
Fire Alarm
Tenant Standards G.T. Mickey Leland Federal Office Building 6
Tenant Standards G.T. Mickey Leland Federal Office Building 7
INTRODUCTION
This document has been compiled to provide guidelines for ongoing tenant interior renovations in the newly renovated Mickey Leland Building. All renovations in the public spaces and corridors need to be designed consistent with the corresponding standards in these guidelines. In the tenant leased spaces, the ceilings and MEP/F need to be designed to meet these guidelines. While an agency can use these guidelines for the rest of their finish-out, there is no requirement for the other scope within the individual agency space to follow these guidelines. An agency can utilize their own agency standards in keeping with the P100.
BUILDING INFORMATION
1. Building/Facility Name: G. T. "Mickey" Leland Federal Office Building
2. Building/Facility Number: TX0298
3. Building/Facility Address: 1919 Smith Street, Houston, Texas 77002
4. Property Manager: Dawn Han, GSA, Gulf Coast Region 07
Telephone: (832) 397 8496
Fax: (281) 228 – 5613
Mobile: (713) 476 - 1798
Email: dawn.han@gsa.gov
Involvement: Responsible for the administration, operation, and maintenance of the building.
Overview of ARRA Project
The project was funded under the American Recovery and Reinvestment Act (ARRA), under the High Performance Green Building (HPGB) criteria. The scope of work included:
An over cladding of the building exterior façade with a new state of the art curtainwall system;
o Upgrade of related structural supporting components, including the capacity to support window cleaning operations off of the roof;
o Upgrades to the lighting systems for daylighting features of the new exterior façade, and related new lighting controls;
o Installation of new ceiling systems provided;
Renovation and upgrade of all public area finishes;
Upgrade building interior for Architectural Barriers Act (ABA) compliance, including build-out of additional ABA restrooms;
Modernization of first floor lobby and the security check-point;
Relocation and renovation of the cafeteria on the first floor;
Replacement of the building air handling units (AHUs) and related air distribution system in the tenant areas;
A new Building Automations System (BAS), integrated with the lighting controls and security systems;
Replacement of the air-side energy recovery systems;
Upgrades to the adjacent parking garage, including structural, lighting, and ABA improvements;
Replacement of the existing breezeway from the parking garage to the building lobby;
mailto:dawn.han@gsa.gov
Tenant Standards G.T. Mickey Leland Federal Office Building 8
Installation of new elevator, and reconstruct existing stairway, for access from parking garage tunnel to the breezeway;
Reconstruction of the plaza area;
Upgrades to the perimeter security barriers;
Addition of solar renewable energy on the top of the parking garage;
Upgrades to the fire alarm system for P-100 and NFPA compliant;
Upgrades to the fire protection system to comply with NFPA codes;
Each floor of the building was vacated so a complete renovations could be accomplished, and included replacement of all carpeting throughout the in the tenant lease along with new paint on all wall;
Removal of all abandoned telecommunications cabling; and
Installation of a new security system for all card readers and security cameras.
General Requirements
Subgroup
DIVISION 01
Tenant Standards G.T. Mickey Leland Federal Office Building 10
Tenant Standards G.T. Mickey Leland Federal Office Building 11
Sustainable Design Requirements
The Mickey Leland Federal Building Renovations was a Modernization project, as further defined in the Facility Standards for the Public Buildings Service, Appendix A
(http://www.gsa.gov/P100). Newly modernized GSA-owned facilities are required to meet the lowest energy consumption level attainable without a resulting increase in life-cycle cost, with a goal of reducing the present value energy cost budget to at least 20 percent below the pre-renovations level. (See Executive Order 13423 and the interagency memorandum of understanding on Federal Leadership in High Performance and Sustainable
Buildings – 2006.) The optimization of energy use for the facility will be delivered through an integrated approach affecting building envelope, mechanical and electrical systems, and interior heat, light and power loads.
The Mickey Leland Federal Building is intended to be a model for sustainability in GSA
Region 7. The following summarizes the sustainable issues that were addressed during the
Project design and construction. It is the intent of these guidelines to create a framework by which the sustainable design can be maintained as renovations occur with tenant agency lease changes.
A. LEED
The Project is currently a Gold certification under LEED NC v2009 rating system.
B. High Performance & Sustainability Building
Moisture Control strategy
Construction IAQ, 72 hour flush out before tenant space occupied
Eliminate ozone depleting compounds for new equipment and/or new kitchen appliances
C. Energy Policy Act of 2005 (EPACT’05)
New HVAC equipment to be energy efficient
Purchase ENERGY STAR or Federal Energy Management Program (FEMP) equipment and appliances
D. Energy Independence & Security Act (EISA) 2007
Use cost effective lighting fixtures
ENERGY STAR Label appliances
Use advanced meters for measurement and verification
E. Life Cycle Costing
Building design energy conservation measures process mandated by law and defined in CFR, Title 10, Part 436, Subpart A: Program Rules of the Federal Energy
Management Program. Governs: Thermal envelope, passive solar features, fenestrations, HVAC, domestic hot water, building automation, lighting, occupant productivity, system maintenance, environmental impact and any other issue that impacts cost over time.
F. Federal Recycled Content Requirements
Provide building materials with recycled content such that postconsumer material and recovered material for EPA-designated products constitutes not less than 10 percent of the total cost of Project materials.
G. Regional Materials
Provide a minimum of 10 percent of building materials (by cost) that are regional materials.
Tenant Standards G.T. Mickey Leland Federal Office Building 12
H. Certified Wood
Provide a minimum of 50 percent (by cost) of wood-based materials that are produced from wood obtained from forests certified by an FSC-accredited certification body to comply with FSC STD-01-001, "FSC Principles and Criteria for
Forest Stewardship."
I. Adhesives, sealants, and sealant primers that are used on the inside of the weatherproofing system and applied on-site shall comply with South Coast Air
Quality Management District (SCAQMD) Rule 1168, effective date of July 1, 2005 and rule amendment date of January 7, 2005
1. Paints and coatings used inside of the weather-proofing system and applied on-site shall comply with the following criteria:
i. Architectural paints and coatings applied to interior walls and ceilings shall not exceed the volatile organic compound (VOC) content limits established in Green Seal Standard GS-11, Paints.
ii. Anti-corrosive and anti-rust paints applied to interior ferrous metal substrates shall not exceed the VOC content limit of 250 g/L established in Green Seal Standard GC-03, Anti-Corrosive Paints.
iii. Clear wood finishes, floor coatings, stains, primers, and shellacs applied to interior elements shall not exceed the VOC content limits established in South Coast Air Quality Management District (SCAQMD)
Rule 1113, Architectural Coatings, rules in effect on January 1, 2004.
2. Do not use composite wood or agrifiber products or adhesives that contain urea-formaldehyde resin.
J. Alternative Energy
A total of 185kW of new photovoltaic panels with structural support and associated electrical controls are installed over the garage. Power produced at the garage is routed to the main electrical Switchboard in the basement of the Mickey Leland
Building. Invertors for PV array are located on 5th floor level of garage.
Commissioning Requirements
As a part of the effort to maintain the sustainability of the Mickey Leland Building, renovations that impact building systems should be re-commissioned so that the original commissioning goals can be maintained. Where new work impacts the systems described below, the GSA Project Managers and design teams should address re-commissioning in their project scope
The following systems were commissioned as a part of the ARRA funded Project renovation:
A. Building Envelope
1. New curtain wall assemblies)
B. Plumbing Systems:
1. Domestic Hot Water Heaters
2. Plumbing Fixtures
i. Spot checks of pressure tests and flushing of piping systems
ii. Irrigation System
Tenant Standards G.T. Mickey Leland Federal Office Building 13
C. Mechanical Systems:
1. Chilled Water Energy Recovery Units
2. Large Chilled Water Air Handling Units
3. Small Chilled Water Air Handling Units
4. Chilled Water Fan Coil Units
5. Self-contained Direct Exchanged Fan Coil Units
6. VAV Terminal Units
7. Master Pressure Control Terminal Units with Heat
8. VAV Pressure Dependent Diffusers
9. Misc. Exhaust / Transfer Fans
10. Toilet Exhaust Fans
11. Garage Exhaust Fans
12. Stairwell Pressurization Fans
13. Miscellaneous tenant space. Supply Fans
14. Building Chilled Water Pumps
15. Building Hot Water Pumps
16. Spot Checks of Duct Testing
17. Systems Integration (Central Building Automation System)
D. Electrical System
1. Lighting Controls / Occupancy Sensors
2. Garage Emergency Generator
3. Fire Alarm/ Fire Life Safety Systems—New Alarm Panel
4. Conveyance Systems—Tunnel/ Breezeway Elevator
Life Safety Review
A life safety review is based on an assessment of the exiting capacity through the egress systems on any floors under construction and the capacity at the level of exit discharge. The following summary is provided to assist in life safety analyses, which should be done for future renovations in the building.
The Mickey Leland Modernization Project reviewed the existing conditions, based on the uses on each floor for each agency. Any required modification were incorporated into the renovation project The occupant loads are provided with corresponding, code-mandated number of exits and total exit width so the number of egressing occupants can safely arrive at the level of exit discharge and discharge through the exiting components. This analysis also reviewed the arrangement of the means of egress to ensure the travel distances, encroachments into exit width, and exposures to hazards are minimized. Since the existing partitions in the tenant agency spaces were to remain and travel distances, dead-end conditions, and egress widths will not be modified as a result of this work, the modernization project did not address any existing code violations resulting from previous work inside tenant space.
The design team did identify two upper floors of the Mickey Leland Build ng that posed the greatest challenge to the existing systems on lower floors. Those were Level 4 (Public
Processing) and Level 12 (Flexible Meeting Space). It was assumed that the highest occupant load for the building will re-side on one of these floors. The egress analysis evaluated the 4th Floor. In accordance with NFPA 101 Section 7.3.1.4, “Where an exit serves more than one story, only the occupant load of each story considered individually shall be used in computing the required capacity of the exit at that story, provided that the required egress capacity of the exit is not decreased in the direction of egress travel.”
Tenant Standards G.T. Mickey Leland Federal Office Building 14
Special consideration was given to the First Floor occupant load since there is convergence on this level. The final design resulted in code compliant exiting at the ground floor for the egress from above and the first floor. The occupant loads determined whether or not the correct number of exits is provided for a space and primarily focused on spaces approaching the threshold for spaces that require more than one means of egress. The secondary goal of the exiting study was to ensure that additional Assembly occupancies could be accommodated on upper floor stair systems and through the level of exit discharge systems accordingly.
The load calculation performed was based on the premise that the overall building (gross area) is a business occupancy and that there are a number of smaller occupancy groups
(net area) that contain occupancies with higher or lower occupant loads (public waiting areas, processing areas, and training rooms vs. storage rooms, mechanical areas, etc.). The occupant loads were calculated using the gross or net areas of rooms and combined work-spaces, and applying published occupant load densities found in NFPA 101 and the IBC.
Some com-mon densities for spaces found in the building are:
A. Offices: 100 sf/occupant
B. Transitioning Corridors (Concourse) 100 sf/occupant
C. Storage: 300 sf/occupant
D. Large Mechanical Areas: 500 sf/occupant
E. Break/Conference Rooms: 15 sf/occupant (net)
F. Concentrated Seating: 7 sf/occupant (net)
G. Standing Cue Areas: 18 in./occupant (net)
The gross area of a floor (roughly 15,350) is used as the starting point for calculating the occupant load of each floor. This calculation does include all spaces within the interior perimeter of the exterior walls of the building (per NFPA 101 Section 3.3.17.2.1). This calculation satisfies the required method for Group B occupancies (the majority of the floors). The Design Team then isolated areas of the floor plan that warranted calculation using the “net area” method in NFPA 101 Section 3.3.17.2.1 and applied the appropriate net occupant load factor from NFPA 101 Table 7.3.1.2. The Design Team also applied a “net area” calculation method to smaller storage rooms and incidental areas on the floor plan.
Occupant loads of dense seating and other assembly areas were based the configuration of the room only (no common areas), per the definitions of “net” area.
All area measurements were conservative in the fact that they included normally unoccupied areas such as intermediate columns, small floor openings, and irregular areas of the floor plan without subtraction. Using the gross area method for the majority of the floor plan also ensures the majority of common areas such as corridors and stairs would be accounted.
Break room occupant loads are added to the overall occupant load of the floor since they can be occupied by different groups of people who are external to the overall office population. Similarly, conference rooms apply the higher occupant load density since it is possible that outside visitors could add to the occupant loads of these rooms. In general, assembly rooms with occupant loads less than 50 persons were considered Group B occupancies and storage rooms less than 250 sf were considered incidental to the Group B.
As stated earlier, larger assembly or storage rooms were deducted from the gross area and occupant loads for those spaces were calculated separately.
Corridors, where occupants may be waiting or circulating, are calculated based on the occupant load factor for the gross business occupancy. The application of a gross occupant load calculation, using 100 sf per occupant, would assign a considerable occupant load to
Tenant Standards G.T. Mickey Leland Federal Office Building 15 the main circulating corridors as well as the individual corridors in the workspaces. In all, this estimate will be conservative since it would assume concurrent occupancy of the corridor space and the actual work areas on every floor.
The occupant loads were determined by dividing the area by the load factor. Any fraction is rounded up to the next whole number for most occupancies. Since storage occupancies have a characteristically low occupant load, only fractions 0.5 or greater are rounded up.
The occupant loads are compared to the egress capacity of the space or the egress capacity of the stairs and corridors serving the space. Using NFPA 101 exit width requirements (NFPA
101 Section 7.3.3.1), The Design Team was able to calculate the exit capacity of each door and stair.
The Design Team assumed a 32-in. clear width for nominal 36-in. doors. The exiting capacity of a 32-in. door is 160 occupants using the NFPA width factor of 0.20 in. per occupant for level exits. Spaces with the minimum 2 doors (as provided at the entrances to stair enclosures on upper floors), will automatically provide capacity for 320 persons.
The exiting capacity of each stair is based on the overall tread width of the stair (44 in.), divided by a width factor of 0.3 in./occupant. The resulting stair capacity was 146 occupants per stair. Since this capacity was less than the capacity of the doors, it was selected as the governing value - 292 occupants per floor.
Regardless of the current configuration of the upper floors, the Design Team’s objective is to provide sufficient exiting width on the first floor to properly accommodate the number of occupants using the existing system on upper floors. The actual occupant load analysis was performed on upper floors to also demonstrate that the reconfiguration of the level of exit discharge was sufficient to accommodate the higher occupant loads of the upper floors and added occupant loads due to exit convergence (Basement/First Floor).
Tenant Standards G.T. Mickey Leland Federal Office Building 16
Facility Construction
DIVISION 03
Concrete
Tenant Standards G.T. Mickey Leland Federal Office Building 18
Tenant Standards G.T. Mickey Leland Federal Office Building 19
Cast In Place Concrete
The lower structure in the building below the second floor is primarily a cast in place concrete construction. The central core of the building is a slip formed cast in place concrete construction. As such it is critical to the overall structural integrity of the building in that it provides the shear structural strength for the building. Opening shall not be cut in this concrete without seeking permission from the GSA Region 7 technical staff.
Precast Concrete
Above the second floor, the predominate structure of the building outside of the central core is precast concrete members. The floor is constructed of pre-cast double tee members with a nominal 2” topping slab with welded wire mesh reinforcing. Locations of all floor cores shall be coordinated with the GSA Region 7 technical staff.
Tenant Standards G.T. Mickey Leland Federal Office Building 20
DIVISION 05
Metals
Tenant Standards G.T. Mickey Leland Federal Office Building 22
Tenant Standards G.T. Mickey Leland Federal Office Building 23
Decorative Formed Metal
Includes Sheet Metal, Miscellaneous Metal, Column Covers, Metal Base, and Trim.
A. General:
Provide sheet metal without pitting, seam marks, roller marks, stains, discolorations, or other imperfections where exposed to view on finished units.
B. Products Provided:
Stainless-Steel Sheet Finishes – No. 4
C. Sealants, Interior:
Nonsag, paintable, nonstaining, latex sealant complying with ASTM C 834; of type and grade required to seal joints in decorative formed metal; and as recommended in writing by decorative formed metal manufacturer. Sealants shall have a VOC content of not more than 250 g/L when calculated according to 40 CFR 59, Subpart
D (EPA Method 24).
Tenant Standards G.T. Mickey Leland Federal Office Building 24
DIVISION 06
Wood, Plumbing & Composites
Tenant Standards G.T. Mickey Leland Federal Office Building 26
Tenant Standards G.T. Mickey Leland Federal Office Building 27
Interior Architectural Woodwork
Where fire-retardant-treated materials are indicated, use materials complying with requirements that are acceptable to authorities having jurisdiction, and with fire-test-response characteristics specified.
When possible, consider using Certified Wood products and materials as “FSC Pure" or "FSC
Mixed Credit" according to FSC STD-01-001, "FSC Principles and Criteria for Forest
Stewardship," and FSC STD-40-004, "FSC Standard for Chain of Custody Certification.
VOC Limits for Installation Adhesives and Sealants: Use products that comply with the following limits for VOC content when calculated according to 40 CFR 59, Subpart D (EPA
Method 24):
Wood Glues: 30 g/L.
Multipurpose Construction Adhesives: 70 g/L.
Structural Wood Member Adhesive: 140 g/L.
Architectural Sealants: 250 g/L.
A. Products Installed:
WB-1 - 2 ½” Painted Wood Base
WB-2 - 4 ½” Painted Wood Base
Color is BM 1595, Rocky Coast
B. Plastic Paneling
Gelcoat-finished, glass-fiber reinforced plastic panels complying with ASTM D 5319.
C. Trim Accessories:
Manufacturer's standard one-piece vinyl extrusions designed to retain and cover edges of panels. Provide division bars, inside corners, outside corners, and caps as needed to conceal edges.
Adhesive shall have a VOC content of 50 g/L or less when calculated according to 40
CFR 59, Subpart D (EPA Method 24).
Sealant shall have a VOC content of 250 g/L or less when calculated according to 40
D. Products Provided:
Kemlite, 0.09 inch, smooth finish.
Tenant Standards G.T. Mickey Leland Federal Office Building 29
DIVISION 07
Thermal and Moisture
Protection
Tenant Standards G.T. Mickey Leland Federal Office Building 30
Tenant Standards G.T. Mickey Leland Federal Office Building 31
Applied Fireproofing
While the building is predominately a concrete structure, there are locations where structural steel is present. It was provided with 2 hour rated protection. Cementitious
Sprayed Fire-Resistive Material was be used on to repair existing conditions damaged during construction or when new steel was incorporated.
A. VOC Content:
Products shall comply with VOC content limits of authorities having jurisdiction and the following VOC limits when calculated according to 40 CFR 59, Subpart D (EPA
Method 24):
1. Flat, Nonflat Paints and Coatings: 50 g/L.
2. Primers, Sealers, and Undercoaters: 100 g/L.
3. Anticorrosive and Antirust Paints Applied to Ferrous Metals: 100 g/L.
B. Product Installed
CAFCO 300 by Isolatek
C. Penetration Firestopping
Where rated assemblies are penetrated, firestopping is required. Provide penetration firestopping that is produced and installed to resist spread of fire according to requirements indicated, resist passage of smoke and other gases, and maintain original fire-resistance rating of construction penetrated. Penetration firestopping systems shall be compatible with one another, with the substrates forming openings, and with penetrating items if any.
D. Penetrations in Fire-Resistance-Rated Walls:
Provide penetration firestopping with ratings determined per ASTM E 814 or UL
1479, based on testing at a positive pressure differential of 0.01-inch wg (2.49 Pa).
E. Penetrations in Horizontal Assemblies:
Provide penetration firestopping with ratings determined per ASTM E 814 or UL
1479, based on testing at a positive pressure differential of 0.01-inch wg (2.49 Pa).
F. Penetrations in Smoke Barriers:
Provide penetration firestopping with ratings determined per UL 1479.
G. W-Rating:
Provide penetration firestopping showing no evidence of water leakage when tested according to UL 1479.
H. Exposed Penetration Firestopping:
Provide products with flame-spread and smoke-developed indexes of less than 25 and 450, respectively, as determined per ASTM E 84.
I. VOC Content: Penetration firestopping sealants and sealant primers shall comply with the following limits for VOC content when calculated according to 40 CFR 59, Subpart D (EPA Method 24):
1. Sealants: 250 g/L.
2. Sealant Primers for Nonporous Substrates: 250 g/L.
3. Sealant Primers for Porous Substrates: 775 g/L.
J. Product Installed:
Hilti Firestop Systems
Tenant Standards G.T. Mickey Leland Federal Office Building 32
Fire-Resistive Joint Systems
A. Joints in or between Fire-Resistance-Rated Construction:
Provide fire-resistive joint systems with ratings determined per ASTM E 1966 or UL
2079.
B. Joints at Exterior Curtain-Wall/Floor Intersections:
Provide fire-resistive joint systems with rating determined by ASTM E 119 based on testing at a positive pressure differential of 0.01-inch wg (2.49 Pa) or ASTM E 2307.
C. Joints in Smoke Barriers:
Provide fire-resistive joint systems with ratings determined per UL 2079.
D. Exposed Fire-Resistive Joint Systems:
Provide products with flame-spread and smoke-developed indexes of less than 25 and 450, respectively, as determined per ASTM E 84.
E. VOC Content:
Fire-resistive joint system sealants shall comply with the following limits for VOC content when calculated according to 40 CFR 59, Sub-part D (EPA Method 24):
1. Architectural Sealants: 250 g/L.
2. Sealant Primers for Nonporous Substrates: 250 g/L.
3. Sealant Primers for Porous Substrates: 775 g/L.
Joint Sealants
Provide joint sealants, backings, and other related materials that are compatible with one another and with joint substrates under conditions of service and application, as stated by sealant manufacturer's published data, and as substantiated by the manufacturer for each application through testing.
A. VOC Content of Interior Sealants:
Provide sealants and sealant primers for use inside the weather-proofing system that comply with the following limits for VOC content when calculated according to 40 CFR
59, Subpart D (EPA Method 24):
1. Architectural Sealants: Not more than 250 g/L.
2. Nonmembrane Roof Sealants: 300 g/L.
3. Single-Ply Roof Membrane Sealants: 450 g/L.
4. Sealant Primers for Nonporous Substrates: Not more than 250 g/L.
5. Sealant Primers for Porous Substrates: Not more than 775 g/L.
B. Latex Sealant:
Non-elastomeric, one part, non-sag, paintable latex sealant that is recommended for exposed applications on the interior. Complying with ASTM C 834, Type OP (opaque sealants).
C. Products Installed: BASF Sonolastic SL2.
DIVISION 08
Openings
Tenant Standards G.T. Mickey Leland Federal Office Building 34
Tenant Standards G.T. Mickey Leland Federal Office Building 35
Hollow Metal Doors and Frames
A. Recycled Content of Steel Products:
1. Provide products with an average recycled content of steel products so post-consumer recycled content plus one-half of pre-consumer recycled content is not less than 20 percent.
2. Provide flush-design doors, 1-3/4 inches (44 mm) thick, of seamless hollow construction, unless otherwise indicated. Construct doors with sheets joined at their vertical edges by continuous welding the full height of the door, with no visible seams on their faces or vertical edges, and all welds ground and finished flush.
3. Fabricate steel door frames, formed to profiles indicated, with full 5/8 inch
(16 mm) stops, and of the following minimum thicknesses.
4. For interior use, form frames from cold- rolled steel sheet of the following thicknesses:
i. Openings up to, and including 48 inches (1200 mm) Wide: 0.053 inch
(1.3 mm).
ii. Openings More Than 48 inches (1200 mm) Wide: 0.067 inch (1.7 mm).
5. Provide frames either saw mitered and full (continuously) welded, or machine mitered and full welded, on back side at frame corners and stops with edges straight and true. Grind welds smooth and flush on exposed surfaces.
B. Product Installed:
Door Components, L.P.
Aluminum Door and Window Frames
Much of the work did and will involve reusing existing aluminum frames and top track. The intent of new material is to match existing material that is being reused.
A. Aluminum Framing:
ASTM B 221 (ASTM B 221M), Alloy 6063-T5 or alloy and temper required to suit structural and finish requirements, not less than 0.062 inch (1.6 mm) thick.
B. High-Performance Organic Finish:
Two-coat fluoropolymer finish complying with AAMA 2604 and containing not less than 70 percent PVDF resin by weight in color coat. Prepare, pretreat, and apply coating to exposed metal surfaces to comply with coating and resin manufacturers' written instructions. Match existing finishes, which do vary somewhat by floor
C. Product Installed:
Versatrac Interior Frames 400 R Series, with adjustable depth throat frames and 1
½” wide face trim
Flush Wood Doors
Much of the work did and will involve reusing existing solid core wood doors. Some are wood veneer. Others are plastic laminate clad. The intent of new material is to match existing material that is being reused.
A. Particleboard Cores: ANSI A208.1, Grade LD-1 or Grade LD-2, made with binder containing no urea-formaldehyde resin.
Tenant Standards G.T. Mickey Leland Federal Office Building 36
B. Hardboard-Faced Door Construction for Opaque Finish:
AWI Section 1300, PC-5 CE.
C. Plastic Laminate for Interior tenant Doors: Nevamar Golden Ash WM8110T Textured
D. Certified Wood:
Flush wood doors shall be certified as "FSC Pure" or "FSC Mixed Credit" according to
FSC STD-01-001, "FSC Principles and Criteria for Forest Stewardship," and to FSC
STD-40-004, "FSC Standard for Chain of Custody Certification
E. Low-Emitting Materials:
Provide doors made with adhesives and composite wood products that do not contain urea formaldehyde.
F. Product Installed:
VT Industries Architectural Wood Doors
Access Doors and Frames
A. Fire-Rated Access Doors and Frames:
Units complying with NFPA 80 that are identical to access door and frame assemblies tested for fire-test-response characteristics according to the following test method and that are listed and labeled by UL or another testing and inspecting agency acceptable to authorities having jurisdiction:
1. NFPA 252 or UL 10B for fire-rated access door assemblies installed vertically.
i. NFPA 288 for fire-rated access door assemblies installed horizontally
Flush Access Doors with Concealed Flanges or Fire-Rated, Flush Access Doors with
Concealed Flanges.
Aluminum Entrances and Storefronts
A. Aluminum:
Conform to the requirements published in AA "Aluminum Standards and Data," referenced ASTM standards.
B. Carbon Steel:
For carbon steel components required to join, reinforce or support the assembly of aluminum components provide carbon steel con-forming to ASTM A 36/A 36M for structural shapes, plates, and bars; ASTM A 1008/A 1008M for cold-rolled sheet and strip; or ASTM A 1011/A 1011M for hot-rolled sheet and strip.
C. Concealed Sealing Materials:
All sealing materials concealed within the entrances and storefronts shall be silicone, compatible with and adherent to each material it will be in contact with, as recommended by the manufacturer to fulfill performance requirements.
Provide sealants for use inside of the weatherproofing system that have a VOC content of
250 g/L or less when calculated according to 40 CFR 59, Sub-part D (EPA Method 24).
Tenant Standards G.T. Mickey Leland Federal Office Building 37
All-Glass Entrances and Storefronts
A. Glass GL-9:
ASTM C 1048, Kind FT (fully tempered), Condition A (uncoated surfaces), Type I
(transparent), tested for surface and edge compression per ASTM C 1048 and for impact strength per 16 CFR 1201 for Category II materials.
B. Aluminum Extrusions:
ASTM B 221 (ASTM B 221M), with strength and durability characteristics of not less than Alloy 6063-T5.
Glazed Aluminum Curtain Walls–Cassette System
The curtain wall system consists of thermally bro-ken cassette system aluminum mullions with a fluropolymer finish, and insulating glass with a high performance low emissivity coating set into the framing with structural silicon to provide a mullion-less appearance.
Exposed aluminum exterior surfaces are finished with Valspar Floropon Classic II 933X440
Bright Silver. Exposed interior aluminum surfaces are finished with Valspar Flurocryl Classic
II KJM0102 Bright Silver.
The new window system will consist of 1/4" glass – ½" airspace – 3/8" laminated glass. The laminated glass should consist of 3/16” plate – 0.060” thick interlayer – 3/16” plate. The interlayer should be a polyvinyl butyral material.
In instances where tenant improvements require new partitions to join the curtain wall, end of partitions should be capped with available attic stock of the custom partition closure extrusions fabricated for the ARRA building renovation. When this attic stock is depleted, floatable trim and adjustable partition closures should be provided. Building standard products for this application are to be Gordon Final Forms Series 911 trim and Gordon
Mullion Mate adjustable aluminum partition closures. The closure configuration appropriate for typical conditions in Leland Building will consist of 2 Mullion Mate 5 assemblies factory spliced back to back and designed to fill openings ranging from 9” to 13¾”. Closures should be powder coated with custom color to match curtain wall.
Door Hardware
Much of the work did and will involve reusing existing door hardware. An inventory of existing hard-ware using a hardware supplier such as Assa Abloy provides an opportunity to inventory existing hardware to be reused and identify hardware that can be reused and hardware which is damaged. New hardware should be proposed to coordinate with the existing hardware being reused. Lock cylinders should use a best keyway.
A. Door Hardware Schedule:
Prepared by or under the supervision of supplier, detailing fabrication and assembly of door hardware, as well as procedures and diagrams. Coordinate the final Door
Hardware Schedule with doors, frames, and related work to ensure proper size, thickness, hand, function, and finish of door hardware.
B. Products Installed:
1. Locket – Corbin Russwin ML2000
2. Trim Design – Corbin Russwin ML2000 and ML20900 ECL
3. Hinges – McKinney Five Knuckle
4. Astragals and Stiles – Pemko
5. Stops and Holders – Rixson
6. Stops, Flush Bolts, Strikes &Coordinators, Guards and Silencers – Rockwood
Tenant Standards G.T. Mickey Leland Federal Office Building 38
Glazing
A. Float Glass:
ASTM C 1036, Type I (transparent glass, flat), Quality q3 (glazing select); class as indicated in schedules at the end of Part 3
B. Fully Tempered Glass:
Provide glass complying with ASTM C1048 Kind FT and meeting the requirements of
ANSI Z97.1. Surface compression shall be equal to or greater than 10,000 psi (69
MPa). After tempering, heat soak 100 percent of all fabricated glass units to
European Union Standard EN14179 to eliminate inclusion related glass break-age.
Statistical heat soaking shall not be permitted.
Tenant Standards G.T. Mickey Leland Federal Office Building 39
DIVISION 09
Finishes
Tenant Standards G.T. Mickey Leland Federal Office Building 40
Tenant Standards G.T. Mickey Leland Federal Office Building 41
Gypsum Board Partitions
Existing partition typically are one layer of 5/8” gypsum board on 3 5/8” metal studs with
Aluminum framing top track (assumed to be a RACO type product).
A. Fire-Resistance-Rated Assemblies:
For fire-resistance-rated assemblies, provide materials and construction identical to those tested in assembly indicated according to ASTM E 119 by an independent testing agency.
B. STC-Rated Assemblies:
For STC-rated assemblies, provide materials and construction identical to those tested in assembly indicated according to ASTM E 90 and classified according to
ASTM E 413 by an independent testing agency.
C. Recycled Content:
Provide gypsum panel products with recycled content such that post-consumer re-cycled content plus one-half of pre-consumer recycled content constitutes a minimum of 40 percent by weight.
D. Regional Materials:
Gypsum panel products shall be manufactured within 500 miles (800 km) of Project site from materials that have been extracted, harvested, or recovered, as well as manufactured, within 500 miles (800 km) of Project site.
E. Gypsum Wallboard:
ASTM C 1396.
1. Regular Type: Typically 5/8” thick with long edges tapered.
2. Type X: Typically 5/8” thick with long edges tapered
F. Flexible Gypsum Board:
ASTM C 1396/C 1396M. Manufactured to bend to fit radii and to be more flexible than standard regular-type gypsum board of same thickness.
1. Thickness: 1/4 inch (6.4 mm).
2. Long Edges: Tapered.
G. Gypsum Ceiling Board:
ASTM C 1396/C 1396M.
1. Thickness: 1/2 inch (12.7 mm).
2. Long Edges: Tapered.
H. Glass-Mat, Water-Resistant Backing Board:
ASTM C 1178/C 1178M, with manufacturer's standard edges.
I. Water-Resistant Gypsum Backing Board:
ASTM C 1396/C 1396M, with manufacturer's standard edges.
Tiling
A. ANSI Ceramic Tile Standard:
Provide tile that complies with ANSI A137.1 for types, compositions, and other characteristics indicated
Tenant Standards G.T. Mickey Leland Federal Office Building 42
B. Static Coefficient of Friction:
For tile installed on walkway surfaces, provide products with the following values as determined by testing identical products per ASTM C 1028.
C. Water-Cleanable Epoxy Grout:
ANSI A118.3, with a VOC content of 65 g/L or less when calculated according to 40
CFR 59, Subpart D.
D. Sealants shall have a VOC content of 250 g/L or less when calculated according to 40
CFR 59, Sub-part D (EPA Method 24).
E. Products installed:
1. TL-1 -
Manufacturer: Daltile
Style/series: Urban Landscape
Color: Silver Lake
Size: 12”x24” Rectified
Grout: Laticrete – 78 sterling silver
Location: Typical Restroom floor
2. TL-2 -
Manufacturer: Daltile
Style/series: Ritten house square collection
Color: arctic white 0190
Finish: semi-gloss
Size: 3"x6"B
Base: cover: -a3361, bullnose-s-4369
Base corner: scr-l-3361, bullnose coner-scr-l-4369
Grout: Mapei - 93 warm gray
Location: Typical Restroom wall
3. TL-3 -
Manufacturer: Daltile
Style/series: quarry tile
Color: dawn 0q63
Size: 6" x 6"
Description: unglazed
Grout: Laticrete - 45 raven
Location: Flooring at all Kitchen Area
Acoustical Panel Ceilings
A. Acoustical Panel Standard:
Provide manufacturer's standard panels of configuration indicated that comply with
ASTM E 1264 classifications as designated by types, patterns, acoustical ratings, and light reflectances unless otherwise indicated.
B. Seismic Performance:
Acoustical ceiling shall with-stand the effects of earthquake motions determined according to ASCE/SEI 7.
C. Surface-Burning Characteristics:
Comply with ASTM E 84; testing by a qualified testing agency. Identify products with appropriate markings of applicable testing agency.
Tenant Standards G.T. Mickey Leland Federal Office Building 43
D. Products installed:
1. ACT-1
Manufacturer: USG
Style/series: Frost Clima Plus – beveled tegular
Color: white
Size: 2’ x 2’
Location: typical tenant spaces and corridors
Note: edge type fl - grid profile (g) Fineline 1/8" dxf
2. ACT-2
Manufacturer: USG
Style/series: sheetrock lay-in panels Clima Plus
Color: white
Size: 2’ x 2’ x ½”
Location: back of house
3. ACT-3
Manufacturer: USG
Style/series: Halcyon Clima Plus Logix panel
Color: white
Size: 6" x 1"
Location: typical elevator lobbies
Note: edge type fl - grid profile (d) Fineline 1/8" dxf
Stone Flooring
For stone flooring installed on walkway surfaces, provide finished installation with the following values as determined by testing identical installations and products per ASTM C
1028 – Level surfaces: Min of 0.6.
Stone for floors shall comply with requirements of FloorScore Standard.
Provide granite complying with ASTM C 615 and NBGQA's "Specifications for Architectural
Granite"
Products Installed:
1. ST-1
Manufacturer: Stone marketing international
Color: Afton White
Finish: flamed
Size: 2’-6” x 5’-0”
Description: granite
Location: ground level lobby
2. ST-2
Manufacturer: ColdSprings Granite
Color: Mesabi Black
Finish: flamed
Location: ground level lobby accent
Tenant Standards G.T. Mickey Leland Federal Office Building 44
Stone Facing
Provide limestone complying with ASTM C 568
A. Water-Cleanable Epoxy Adhesive:
ANSI A118.3, with a VOC content of 65 g/L or less when calculated according to 40
CFR 59, Subpart D (EPA Method 24).
B. Joint Sealants:
Manufacturer's standard sealants of characteristics indicated below and will not stain the stone they are applied to.
C. VOC Content:
250 g/L or less when calculated according to 40 CFR 59, Subpart D (EPA Method 24).
D. Product Installed:
ST-3
Manufacturer: Vermont Structural Slate
Color: Sheffield Vein Cut
Finish: Honed
Description: limestone
Location: ground level lobby wall
Base and Accessories
A. FloorScore Compliance:
Stone for floors shall comply with requirements of FloorScore Standard
B. Adhesives:
Water-resistant type recommended by manufacturer to suit resilient products and substrate conditions indicated.
C. VOC Content:
Comply with the following limits when calculated according to 40 CFR 59, Subpart D
(EPA Method 24):
1. Cove Base Adhesives: Not more than 50 g/L.
2. Rubber Floor Adhesives: Not more than 60 g/L.
Installed products:
RB-1 manufacturer: Flexco
Color: 018 - baby breath
Description: 2 1/2" cove rubber base
Location: typical tenant space
RB-2 manufacturer: Johnsonite
Color: white
Description: 2 1/2" straight rubber base
Location: typical tenant corridor
RB-3 manufacturer: Roppe
Color: 161 snow
Description: 10" rubber stringer and wall base
Location: ground level
Tenant Standards G.T. Mickey Leland Federal Office Building 45
Resilient Tile Flooring
Prepare substrates according to manufacturer's written recommendations to ensure adhesion of resilient products.
Trowelable Leveling and Patching Compounds: Latex-modified, Portland cement based or blended hydraulic cement based formulation provided or approved by resilient product manufacturer for applications indicated.
Adhesives: Water-resistant type recommended by manufacturer to suit resilient products and substrate conditions indicated. Use adhesives that comply with the following limits for
VOC content when calculated according to 40 CFR 59, Subpart D (EPA Method 24) - VCT and Asphalt Tile Adhesives: Not more than 50 g/L.
FloorScore Compliance: Resilient tile flooring shall comply with FloorScore Standard
Products installed:
VT-1 manufacturer: Armstrong
Style/series: Safety Zone Excelon slip-retardant
Color: 57002 weathered alabaster
Location: back of house corridors level 1
VT-2 manufacturer: Armstrong
Color: 51941 polar white
Location: Public corridors level 1
VT-3 manufacturer: Armstrong
Style/series: Bio-based striations
Color: Warm grey T3608
Size: 12” x 24”
Location: Level 5
VT-4 manufacturer: Armstrong
Style/series: Bio-based striations
Color: Twilight T3603
Size: 12” x 24”
Location: Level 5
VT-5 manufacturer: Armstrong
Style/series: static dissipative tile
Color: 51951 armor grey
Size: 12" x 12"
Location: level 5
VT-6 manufacturer: Flexco
Color: French Grey with Black
Size: 12" x 12"
Location: Tunnel Elevator Cab Floor
Tenant Standards G.T. Mickey Leland Federal Office Building 46
VT-7 manufacturer: Armstrong
Style/series: imperial texture standard Excelon
Color: 5903 blue gray
Location: tenant spaces - per finish plans
Tile Carpeting
Emissions: Provide carpet tile that complies with testing and product requirements of CRI's
"Green Label Plus" program.
Trowelable Leveling and Patching Compounds: Latex-modified, hydraulic-cement-based formulation provided by or recommended by carpet tile manufacturer
Adhesives: Water-resistant, mildew-resistant, nonstaining type to suit products and subfloor conditions indicated, that complies with flammability requirements for installed carpet tile and that is recommended by carpet tile manufacturer.
VOC Content: Provide adhesives with VOC content not more than 50 g/L when calculated according to 40 CFR 59, Subpart D (EPA method 24).
CPT-1 Manufacturer: J&J Invision
Style/series: mache trace (7609) modular
Color: 452 paste
Installation: ashlar
CPT-2 manufacturer: J&J Invision
Style/series: mache trace special #961-449313-004-01
Location: floors 2, 10 (conference rooms) and all corridors
CPT-3 manufacturer: J&J Invision
Style/series: mache trace special #961-449313-004-01
Location: tunnel
CPT-4 manufacturer: J&J Invision
Color: 438 litho
Location: floors 2,4,6,7,8,11,15,23
CPT-5 manufacturer: J&J Invision
Style/series: mache trace special #961-449313-004-07
Location: floors 3, 9 , 12, 16, 17, 18, 19, 20, 22
CPT-6 manufacturer: Shaw
Style/series: stereo # 59250
Color: 50100 surf w/ ecoworx
Location: Floor 4 (IRS customer service)
Tenant Standards G.T. Mickey Leland Federal Office Building 47
CPT-7 manufacturer: J&J Invision
Style/series: mache trace (7609) modular
Color: 443 sketch
Location: floors 4, 8, 10, 11, 14, 15, 16, 21, 22
CPT-8 manufacturer: J&J Invision
Color: 453 stencil
Location: floors 8, 9, 10, 11
CPT-9 manufacturer: J&J Invision
Style/series: tumbled stone (7955) modular
Color: 326 agate
Description: carpet tile
Location: Floor 23 (IRS)
CPT-10 manufacturer: J&J Invision
Style/series: mache trace special-963-454892-001-03
Description: carpet tile
Location: level 4, level 5, level 8
Interior Painting
Interior Gypsum Board Primer: Factory-formulated latex-based primer for interior application
Interior Ferrous-Metal Primer: Factory-formulated quick-drying rust-inhibitive metal primer
Interior Zinc Coated Metal Primer: Factory formulated galvanized metal primer
Interior Metal – Galvanized Metal Primer
Latex, Interior, Institutional Low Odor/VOC, Flat (Gloss Level 1)
Interior Flat Latex-Emulsion Size: Factory-formulated flat latex-based interior paint.
Latex, Interior, Institutional Low Odor/VOC, (Gloss Level 3)
Latex, Interior, Institutional Low Odor/VOC, Semi-Gloss (Gloss Level 5)
Tenant Standards G.T. Mickey Leland Federal Office Building 48
P-1 manufacturer: Benjamin Moore
Color: oc-131 white down
Finish: egg shell
P-2 manufacturer: Benjamin Moore
Color: oc-67 ice mist
Finish: egg shell
Location: typical corridors, common areas
P-3 manufacturer: Benjamin Moore
Finish: flat
Location: gyp. Bd. Ceiling
P-4 manufacturer: PPG
Color: 530-1 silver feather
Finish: semi-gloss
Location: typ. Restroom
P-5 manufacturer: Benjamin Moore
Location: janitor's closet
P-6 manufacturer: Sherwin Williams
Color: sw6242 bracing blue
Location: level 23 accent wall
P-7 manufacturer: Sherwin Williams
Color: sw6516 down pour
P-8 manufacturer: Sherwin Williams
Color: sw6528 cosmos
P-9 manufacturer: Sherwin Williams
Color: sw6914 rice paddy
P-10 manufacturer: Sherwin Williams
Color: sw6601 tanager
Tenant Standards G.T. Mickey Leland Federal Office Building 49
P-11manufacturer: Sherwin Williams
Color: sw6130 mannered gold
P-12 manufacturer: Sherwin Williams
Color: sw6507 resolute blue
P-13 manufacturer: Sherwin Williams
Color: sw6307 fine wine
P-14 manufacturer: Sherwin Williams
Color: sw6510 loyal blue
P-15 manufacturer: Sherwin Williams
Color: sw6866 heartthrob red
Location: level 5 accent wall
P-16 manufacturer: Sherwin Williams
Color: sw7063 - nebulous white
Location: garage stairwell walls
P-17 manufacturer: Sherwin Williams
Color: sw7067 - cityscape
Location: garage steel stairs, doors & railings
Aluminum Closure Piece
Closure piece between demising wall and mullion: Gordon Mullion Mate (3-5)
Tenant Standards G.T. Mickey Leland Federal Office Building 50
DIVISION 10
Specialties
Tenant Standards G.T. Mickey Leland Federal Office Building 52
Tenant Standards G.T. Mickey Leland Federal Office Building 53
Interior Signage
Tenant Standards G.T. Mickey Leland Federal Office Building 54
Tenant Standards G.T. Mickey Leland Federal Office Building 55
Tenant Standards G.T. Mickey Leland Federal Office Building 56
Tenant Standards G.T. Mickey Leland Federal Office Building 57
Tenant Standards G.T. Mickey Leland Federal Office Building 58
Tenant Standards G.T. Mickey Leland Federal Office Building 59
Toilet Compartments
Stainless-Steel Finish: No. 4 bright, directional polish on exposed faces. Protect exposed surfaces from damage by application of strippable, temporary protective covering before shipment.
Product Installed: Accurate Stainless Steel Ceiling Hung Partitions
Toilet, Bath, and Laundry Accessories
Products Installed: American Specialties, Inc.
Dual Toilet Paper Holder. Model # 0697-GAL
Partition Mounted Toilet Paper Dispenser with Sanitary Disposal. Model # 04813
Surface Mounted Sanitary Napkin Disposal. Model #0852
Semi-recessed Roll Paper Towel Dispenser. Model # 04523-6
Recessed Automatic Roll Paper Towel Dispenser and Waste Receptacle. Model # 046924A
Stainless Steel Free Standing Waste Receptacle. Model # 0810/0811
Lavatory Mounted Soap Dispenser. Model # 0332
Wall Mounted Automatic Foam Soap Dispenser. Model # 20365
Surface Mounted Seat Cover Dispenser. Model #0477-SM
1-1/2” DIA Grab Bar Series with Snap-on Flange Covers. Model #3800
Interlock Stainless Steel Framed Mirror. Model #0600
Fire-Protection Specialties
Product Installed: Activar Fire Protection Cabinets with vertical duo panel with pull and Saf-
T-Lok. Provide Red vertical FE Letters.
Tenant Standards G.T.