This is a solicitation notice for full maintenance services at federal facilities in Houston, Beaumont, and Galveston, Texas. Services include operation and maintenance, custodial work, and grounds maintenance at seven buildings totaling over 1.3 million rentable square feet. The facilities support various federal agencies including Customs, FBI, and GSA. The contractor must provide management, labor, materials, equipment, and subcontractors to deliver the required services from an anticipated May 2021 start date. This procurement is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses with a $41.5 million size standard under NAICS 561210.

View the file

Other files

File Type Posted
Amendment 0004 47PH0220R0017 SF33.pdf PDF
Amendment 0004 Questions and Answers.pdf PDF
Amendment 0004 Figure B-3 Pricing of Services .xlsx XLSX spreadsheet
Amendment 0004 SF30.pdf PDF
Amendment 0003 Questions and Answers.pdf PDF
Amendment 0003 47PH0220R0017 SF33.pdf PDF
Amendment 0003 BL8 Leland Davits and Anchor Inspection Report.pdf PDF
Amendment 0003 BL7 Leland Design Guide.pdf PDF
Amendment 0003 Houston Galveston Beaumont OM_FM Spec Amend 0003 7 Jan 21.pdf PDF
47PH0220R0017 Amendment 0003.pdf PDF
Amendment 0002 Houston Galveston Beaumont OM FM Spec 21 Dec 20.pdf PDF
Amendment 0002 BL5 Work Order History.xlsx XLSX spreadsheet
47PH0220R0017 Amendment 0002.pdf PDF
Amendment 0001 Attachment 4 Flag Policy.pdf PDF
Amendment 0001 Pre-Proposal Conference Houston Beaumont and Galveston.pptx PPTX presentation
Amendment 0001 Houston Galveston Beaumont OM_FM Spec 14 Dec 20 - Google Docs.pdf PDF
Amendment 0001 BL2 Inventory to Include Fire Alarm Devices.xlsx XLSX spreadsheet
47PH0220R0017 Amendment 0001 SF30.pdf PDF
Amendment 0001 Pre-Proposal Conference Questions and Answers.pdf PDF
Amendment 0001 Figure B-3 Pricing 5 YEAR- TOTAL_ESTIMATES.xlsx XLSX spreadsheet
BL2 Inventory to Include Fire Alarm Devices.pdf PDF
Exhibit M7 - Qualificaiton of Electrical Testing Technicians.pdf PDF
Exhibit M2 - Green Purchasing Report.pdf PDF
Figure L-3 Past Performance Questionnaire.pdf PDF
Exhibit C6 - Recycle Solid Water Trash Report.pdf PDF
Exhibit C2 Custodial Quality Assurance Surveillance Plan.pdf PDF
Exhibit C1 Building Information Sheet.pdf PDF
Attachment 1 Collective Bargaining Agreement for O_M personnel with Wage Determination.pdf PDF
Figure L-2 Management Plan Baseline.pdf PDF
Exhibit C8 - GSA Form 3638 Pest Control Work and Inspection Report.pdf PDF
Exhibit M4 - Bldg Op Plan Template.pdf PDF
Exhibit M10- PV Service Schedule V5.pdf PDF
Exhibit C4 - Building Exterior and Hardscape Plan.pdf PDF
Exhibit C7 - PBS Waste Audits.pdf PDF
47PH0220R0017 Solicitation and Specifications.pdf PDF
Exhibit M3 - Environmental Sustainable Products.pdf PDF
BL5 Work Order History.pdf PDF
Figure B-1 for Union and Non Union Contracts.xlsx XLSX spreadsheet
BL6 PM Report.pdf PDF
BL3 Location General Information .pdf PDF
Exhibit C3 - Surveilence Form 1181-A.pdf PDF
Exhibit M9 Preventative Maintenance 2018 GSA OM Guide.pdf PDF
Exhibit M1 Quality Assurance Surveillance Plan.pdf PDF
Figure B-3 Pricing 5 YEAR- TOTAL_ESTIMATES.xlsx XLSX spreadsheet
Figure L-1 Management Plan Worksheet.xlsx XLSX spreadsheet
BL1- Houston_Galveston Fire Extinguisher Report.pdf PDF
Exhibit M8 - Misc Best Practices Shave Energy.pdf PDF
Exhibit M5 - Smart Buildings.pdf PDF
BL4 Roof Information.pdf PDF
Exhibit M6 Water Treatment.pdf PDF
Show 40 more

Latest 50 of 54 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

List of Work Orders

Work OrderDescriptionWork TypeWork Sub-TypeStatusLocation DescriptionAssetAsset TagEquipment IDTarget StartIs dynamicDynamic Job Plan appliedSiteLocation
19-48866987BLDG., Source: P077KETX0701HSTN1 - LaBranch FB, Houston TX:io16_2 / Tangent_Alarm Timestamp: 01-Sep-19 8:54:02 PM UTC State: Offnormal Text: Tangent Down/ Fault (GSA/BAS)CMEQFAILCLOSETX0701HO-LABRANCH FEDERAL BLDG9/1/19 4:45 PMNO0760648
19-48867044BLDG., P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:02046 Room Temperature Timestamp: 01-Sep-19 10:20:53 PM UTC State: Offnormal Text: P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:02046 Room Temperature is above 80.0 °F Deg F (GSA/BAS)CMEQFAILCLOSETX0298ZZ-GT LELAND FEDERAL BLDG9/1/19 6:15 PMNO0761276
19-48867157BLDG.,P077KETX0701HSTN1 - LaBranch FB, Houston TX:io16_2 / Tangent_Alarm Timestamp: 02-Sep-19 1:01:14 PM UTC State: Offnormal Text: Tangent Down/ Fault (GSA/.BAS)CMEQFAILCLOSETX0701HO-LABRANCH FEDERAL BLDG9/2/19 9:00 AMNO0760648
19-48911028TIMES 2-P077KETX0211HSTN1 - Bob Casey CH, Houston TX:CHWPumpVSD_FaultCHWPump3 Timestamp: 03-Sep-19 4:13:24 PM UTC State: Offnormal Text: Alarm Active!!-(EMAIL) 9/3/19CMEQFAILCLOSETX0211ZZ-Basement-Room-B-202973034TX0211P03A019TX0211ZZ-PMP-02-P03A-199/3/19 5:00 PMNO0789648
19-48911055P077KETX0211HSTN1 - Bob Casey CH, Houston TX:CHWP1_FaultCHWP1 Timestamp: 03-Sep-19 5:08:27 PM UTC State: Offnormal Text: Alarm Active!!-(EMAIL) 9/3/19CMEQFAILCLOSETX0211ZZ-Entire Building9/3/19 5:00 PMNO0763115
19-48911059Source: P077KETX0211HSTN1 - Bob Casey CH, Houston TX:CHWP2_FaultCHWP2 Timestamp: 03-Sep-19 4:32:13 PM UTC State: Offnormal Text: Alarm Active!!-(EMAIl) 9/3/19CMEQFAILCLOSETX0211ZZ-Basement1821872TX0211ZZ-BAS-JACE-GSAlinkTX0211ZZ-BAS-03-18218729/3/19 5:00 PMNO0763114
19-48911089P077KETX0701HSTN1 - LaBranch FB, Houston TX:TestAlarm Timestamp: 03-Sep-19 1:09:25 PM UTC State: Offnormal Text: This is a Test Alarm.-(EMAIl) 9/3/19CMEQFAILCLOSETX0701HO-Entire Building9/3/19 5:00 PMNO0763818
19-48914420Source: P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:P077KETX0298HSTN1:Chiller3Alarm Timestamp: 03-Sep-19 11:53:26 PM UTC State: Offnormal Text: -(EMAIL) 9/4/19CMEQFAILCLOSETX0298ZZ-Entire Building9/4/19 9:00 AMNO0763303
19-48928016P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:P077KETX0298HSTN1:Chiller3Alarm Timestamp: 05-Sep-19 5:17:39 AM UTC State: Offnormal Text: -(eMAIL) 9/5/19CMEQFAILCLOSETX0298ZZ-Entire Building9/5/19 8:00 AMNO0763303
19-48929095607-LIGHT OUT-(PA) 9/4/19CMCORRECTCLOSETX0081ZZ-Entire Building375478TX0081F34A006TX0081ZZ-LGI-F34A-69/5/19 10:00 AMNO0763002
19-48929109327-LIGHT FIXTURE COVER HANGING-(PA) 9/4/19CMCORRECTCLOSETX0081ZZ-Entire Building375463TX0081F34A003TX0081ZZ-LGI-F34A-39/5/19 10:00 AMNO0763002
19-4892911613TH FL MRCH RM-NEED TO BE SWEPT-(PA) 9/4/19CMCORRECTCLOSETX0081ZZ-Entire Building9/5/19 10:00 AMNO0763002
19-48929120LOBBY-NEED TO UPDATE MISSING ALERT POSTERS-(PA) 9/3/19CMCORRECTCLOSETX0081ZZ-Floor 019/5/19 10:00 AMNO0763004
19-48929128-SOME LIGHTS OUT-(PA) 9/4/19CMCORRECTCLOSETX0081ZZ-Entire Building375458TX0081F34A002TX0081ZZ-LGI-F34A-29/5/19 10:00 AMNO0763002
19-48929136STAIR A 4TH FL-LIGHT OUT-(PA) 9/4/19CMCORRECTCLOSETX0081ZZ-Entire Building375468TX0081F34A004TX0081ZZ-LGI-F34A-49/5/19 10:00 AMNO0763002
19-489291536TH FL CRTRM-LIGHT OUT-(PA) 9/4/19CMCORRECTCLOSETX0081ZZ-Exterior-Outside970842TX0081L04A006TX0081ZZ-LGE-L04A-69/5/19 10:00 AMNO0789230
19-4892916012TH FL-LIGHT OUT-(PA) 9/3/19CMCORRECTCLOSETX0211ZZ-Entire Building377352TX0211F34A001TX0211ZZ-LGI-F34A-19/5/19 10:00 AMNO0763115
19-489291677TH FL-LIGHT OUT IN HALLWAY-(PA) 9/3/19CMCORRECTCLOSETX0211ZZ-Floor 079/5/19 10:00 AMNO0763123
19-489291733RD FL-LIGHT OUT IN HALLWAY-(PA) 9/3/19CMCORRECTCLOSETX0211ZZ-Floor 039/5/19 10:00 AMNO0763119
19-4892931311TH FL-LIGHT OUT ELEVATOR LOBBY-(PA) 9/5/19CMCORRECTCLOSETX0211ZZ-Floor 119/5/19 10:00 AMNO0763127
19-48929318LOBBY-LIGHT OUT ELEVATOR LOBBY-(PA) 8/30/19CMCORRECTCLOSETX0211ZZ-Floor 019/5/19 10:00 AMNO0763117
19-489293216002-CRTRM LIGHT OUT-(PA) 8/300/19CMCORRECTCLOSETX0211ZZ-Floor 069/5/19 10:00 AMNO0763122
19-48929324B-524-LIGHT OUT IN CENTRAL PLANT-(PA) 8/30/19CMCORRECTCLOSETX0211ZZ-Basement9/5/19 10:00 AMNO0763114
19-48929329B-524-CLOGGED DRAIN-(PA) 8/30/19CMCORRECTCLOSETX0211ZZ-Basement9/5/19 10:00 AMNO0763114
19-4892933412605-LIGHT OUT INFRONT OF RM-(PA) 9/4/19CMCORRECTCLOSETX0211ZZ-Entire Building377352TX0211F34A001TX0211ZZ-LGI-F34A-19/5/19 10:00 AMNO0763115
19-4892934010TH FL-LIGHT OUT IN HALLWAY-(PA) 9/4/19CMCORRECTCLOSETX0211ZZ-Entire Building377352TX0211F34A001TX0211ZZ-LGI-F34A-19/5/19 10:00 AMNO0763115
19-4892934911TH FL-HALLWAY LIGHT OUT-(PA) 9/4/19CMCORRECTCLOSETX0211ZZ-Floor 119/5/19 10:00 AMNO0763127
19-48929351BLDG-NEED TO UPDATE REGISTRY-(PA) 9/3/19CMCORRECTCLOSETX0081ZZ-Entire Building9/5/19 10:00 AMNO0763002
19-48929354PLANT-NEED TO REPLACE WATER TREATMENT ES3002-(PA) 9/3/19CMCORRECTCLOSETX0081ZZ-Basement-Central Plant970941TX0081W08A004TX0081ZZ-WTM-W08A-49/5/19 10:00 AMNO0789227
19-48929358MECH 4-CONDENSATION WATER ON FLOOR-(PA) 9/3/19CMCORRECTCLOSETX0081ZZ-Entire Building9/5/19 10:00 AMNO0763002
19-48929363735-DRAIN LINE CLOGGED-(PA) 8/28/19CMCORRECTCLOSETX0081ZZ-Floor 07-Mechanical Equipment Room970781TX0081A11A018TX0081ZZ-AHU-01-A11A-189/5/19 10:00 AMNO0789254
19-489293685TH FL-BATTERIES OUT IN FIRE PANEL-(PA) 8/26/19CMCORRECTCLOSETX0298ZZ-Floor 059/5/19 10:00 AMNO0763309
19-489293747TH FL-BATTERIES OUT IN FIRE PANEL-(PA) 8/29/19CMCORRECTCLOSETX0298ZZ-Floor 079/5/19 10:00 AMNO0763311
19-489293788TH FL-HAD TO UNLOCK CONFERENCE SPACE-(PA) 8/20/19CMCORRECTCLOSETX0298ZZ-Floor 089/5/19 10:00 AMNO0763312
19-48929384BASEMENT-CHEMICAL VALVE BROKEN ON CHEMICAL FEEDER-(PA) 8/19/19CMCORRECTCLOSETX0298ZZ-Basement9/5/19 10:00 AMNO0763302
19-489293894TH FL-LRR HAD LEAK AT BACK OF TOILET-(PA) 8/30/19CMCORRECTCLOSETX0298ZZ-Floor 049/5/19 10:00 AMNO0763308
19-489293944TH FL HCRR-TOWEL DISPENSER IS STUCK-(PA) 8/30/19CMCORRECTCLOSETX0298ZZ-Floor 049/5/19 10:00 AMNO0763308
19-489293982ND FL-CLOTHES HOOK LOOSE-(PA) 8/30/19CMCORRECTCLOSETX0298ZZ-Floor 029/5/19 10:00 AMNO0763306
19-489294016TH FL-LIGHT OUT IN EXECUTIVE AREA-(PA) 9/3/819CMCORRECTCLOSETX0435HF-Floor 069/5/19 10:00 AMNO0763572
19-489294056TH FL-LIGHT OUT IN ERT STORAGE RM-(PA) 9/3/19CMCORRECTCLOSETX0435HF-Entire Building9/5/19 10:00 AMNO0763565
19-48929410SSE ENT-BARRIER STUCK ON DOWN POSITION-(PA) 9/3/19CMCORRECTCLOSETX0435HF-Exterior9/5/19 10:00 AMNO0763566
19-489294206TH FL EAST-LIGHT OUT EAST HALLWAY-(PA) 9/3/19CMCORRECTCLOSETX0435HF-Floor 069/5/19 10:00 AMNO0763572
19-48929425663-LIGHT OUT-(PA) 9/3/19CMCORRECTCLOSETX0435HF-Floor 069/5/19 10:00 AMNO0763572
19-48929431ANNEX-LIGHT OUT IN ANNEX HALLWAY-(PA) 9/3/19CMCORRECTCLOSETX0435HF-Entire Building9/5/19 10:00 AMNO0763565
19-48929438FIRE PUMP RM-FIRE PUMP CLOGGED DRAIN & PACKING LEAKING-(PA) 8/27/19CMCORRECTCLOSETX0435HF-Entire Building9/5/19 10:00 AMNO0763565
19-48929443DAYCARE-DOOR NOT WORKING-(PA) 9/4/19CMCORRECTCLOSETX0701HO-Floor 019/5/19 10:00 AMNO0763820
19-489294461 HALLWAY-WATER FOUNTAIN NO COLD WATER-(PA) 9/4/19CMCORRECTCLOSETX0701HO-Floor 019/5/19 10:00 AMNO0763820
19-4892944910136-TOILET CLOGGED-(PA) 9/4/19CMCORRECTCLOSETX0701HO-Floor 019/5/19 10:00 AMNO0763820
19-489462002nd FLR (2046,2013w,2004,2047, 2210), 077KETX0298HSTN2 - Mickey Leland FB, Houston TX:02210 Room Temperature is above 80.0 °F Deg F (GSA/BAS)CMEQFAILCLOSETX0298ZZ-GT LELAND FEDERAL BLDG9/6/19 8:45 PMNO0761276
19-4894622220th (20101) P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:020101 Room Temperature Timestamp: 07-Sep-19 10:50:00 PM UTC (GSA/BAS)CMEQFAILCLOSETX0298ZZ-GT LELAND FEDERAL BLDG9/7/19 5:30 PMNO0761276
19-48946243BLDG, P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:P077KETX0298HSTN1:Chiller3Alarm Timestamp: 07-Sep-19 12:47:54 AM UTC State: Offnormal Text: (GSA/BAS)CMEQFAILCLOSETX0298ZZ-GT LELAND FEDERAL BLDG9/9/19 9:59 AMNO0761276
19-49131172P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:P077KETX0298HSTN1:Chiller3Alarm Timestamp: 10-Sep-19 11:45:50 PM UTC State: Offnormal-(EMAIL) 9/11/19CMEQFAILCLOSETX0298ZZ-Entire Building9/11/19 10:00 AMNO0763303
19-49131174P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:P077KETX0298HSTN1:Chiller1Alarm Timestamp: 11-Sep-19 12:12:18 AM UTC State: Offnormal-(EMAIL) 9/11/19CMEQFAILCLOSETX0298ZZ-Entire Building9/11/19 10:00 AMNO0763303
19-49131175Source: P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:Pim_Ahu RA Humidity Alarm Timestamp: 11-Sep-19 1:25:22 AM UTC State: Offnormal Text: P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:Pim_Ahu RA Humidity Alarm is in Alarm-(EMAIL) 9/11/19CMEQFAILCLOSETX0298ZZ-Entire Building9/11/19 10:00 AMNO0763303
19-49828540bldg., Source: P077KETX0211HSTN1 - Bob Casey CH, Houston TX:CHWP1_FaultCHWP1 Timestamp: 17-Sep-19 4:54:00 PM UTC State: Offnormal Text: Alarm Active!! (GSA/BAS)CMEQFAILCLOSETX0211ZZ-Basement1286944TX0211R17C002TX0211ZZ-CHL-MB2-12869449/17/19 1:00 PMNO0763114
19-49839054P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:P077KETX0298HSTN1:Chiller1Alarm Timestamp: 15-Sep-19 2:00:19 PM UTC State: Offnormal-(EMAIL) 9/17/19CMEQFAILCLOSETX0298ZZ-Entire Building9/17/19 3:00 PMNO0763303
19-49839539P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:RA_Humidity Timestamp: 15-Sep-19 2:33:22 PM UTC State: Offnormal Text: P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:RA_Humidity is above 60 %RH-(EMAIL) 9/17/19CMEQFAILCLOSETX0298ZZ-Entire Building9/17/19 3:00 PMNO0763303
19-49840093NiagaraNetwork P077KETX0297HSTN1 - Alliance Tower, Houston TX Timestamp: 15-Sep-19 9:53:55 PM UTC State: Offnormal Text: Ping Failed-(EMAIL) 9/17/19CMEQFAILCLOSETX0297ZZ-Basement-Room-B-07976767TX0297C04A001TX0297ZZ-BAS-01-C04A-19/17/19 3:00 PMNO0790683
19-49856014P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:P077KETX0298HSTN1:AHU1_FanStatus Timestamp: 18-Sep-19 5:39:47 PM UTC State: Offnormal Text: P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:P077KETX0298HSTN1:AHU1_FanStatus is in Alarm-(EMAIl0 9/18/19CMEQFAILCLOSETX0298ZZ-Entire Building9/18/19 5:00 PMNO0763303
19-49856110NiagaraNetwork P077KETX0101HSTN2 - Customs House (Houston Texas) Platform Connection Timestamp: 18-Sep-19 10:08:56 PM UTC State: Offnormal Text: Ping Failed-(EMAIl0 9/18/19CMEQFAILCLOSETX0101ZZ-Entire Building1509883TX0101BAS JACETX0101ZZ-BAS-03-15098839/18/19 6:15 PMNO0763016
19-49856112Source: NiagaraNetwork P077KETX0211HSTN2 - Bob Casey CH, Houston TX Timestamp: 18-Sep-19 10:08:33 PM UTC State: Offnormal Text: Ping Failed-(EMAIL) 9/18/19CMEQFAILCLOSETX0211ZZ-Basement1509898TX0211BAS JACE 2TX0211ZZ-BAS-03-15098989/18/19 6:15 PMNO0763114
19-50246287bldg., Source: P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:RA_Humidity Timestamp: 22-Sep-19 11:27:15 AM UTC State: Offnormal Text: P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:RA_Humidity is above 60 %RH (GSA/BAS)CMEQFAILCLOSETX0298ZZ-Floor 02381506TX0298A11A009TX0298ZZ-AHU-01-A11A0099/22/19 7:15 AMNO0763306
19-50340447OUTSIDE-SEVERAL LIGHTS OUT AT CORNERS OF BUILDING ON GESSNER-(PA) 9/3/19CMCORRECTCLOSETX0297ZZ-Exterior-Outside976892TX0297L04B001TX0297ZZ-LGE-L04B-19/27/19 10:00 AMNO0790688
19-50340452B-04-1-COVER HOLE IN SHEETROCK IN SHOP AREA-(PA) 9/18/19CMCORRECTCLOSETX0297ZZ-Basement9/27/19 10:00 AMNO0763279
19-50340462G-4-BELT DAMAGED TORN ON CEILING HUNG UNIT IN CHILLER RM-(PA) 9/18/19CMCORRECTCLOSETX0297ZZ-Garage, 2nd Level-Chiller Mechanical Room976868TX0297I04A002TX0297ZZ-FCU-I04A-29/27/19 10:00 AMNO0790823
19-50340470ROOF-FILL EMERGENCY GENERATOR DIESEL TANK BELOW 3/4-(PA) 9/5/19CMCORRECTCLOSETX0297ZZ-Penthouse-Mechanical Equipment Room976815TX0297E41A001TX0297ZZ-EMG-01-E41A-19/27/19 10:00 AMNO0790835
19-50340474ROOF-FILTER MEDIA ON LOUVERS AIR VENTS IN GENERATOR RM WORN OUT-(PA) 9/9/19CMCORRECTCLOSETX0297ZZ-Penthouse-Mechanical Equipment Room976872TX0297F32A017TX0297ZZ-FLT-01-F32A-179/27/19 10:00 AMNO0790835
19-50340478170/409/1209-INSTALL HANGERS IN JANITORIAL CLOSETS-(PA) 9/26/19CMCORRECTCLOSETX0297ZZ-Entire Building9/27/19 10:00 AMNO0763280
19-50340481B-04-STAINED TILE IN MAINTENANCE OFFICE-(PA) 9/26/19CMCORRECTCLOSETX0297ZZ-Basement9/27/19 10:00 AMNO0763279
19-50340484BASEMENT-LIGHT OUT IN BASEMENT LOBBY-(PA) 9/13/19CMCORRECTCLOSETX0297ZZ-Entire Building381313TX0297F34H001TX0297ZZ-LGI-F34H-19/27/19 10:00 AMNO0763280
19-50340489B-02-LEAK UNDER LEFT SINK-(PA) 9/13/19CMCORRECTCLOSETX0297ZZ-Basement9/27/19 10:00 AMNO0763279
19-50340504GARAGE-LIGHT OUT ON 2ND FL STAIRWELL ELEVATOR STAIRWELL-(PA) 9/17/19CMCORRECTCLOSETX0297ZZ-Basement381285TX0297F34H002TX0297ZZ-LGI-F34H-29/27/19 10:00 AMNO0763279
19-50340521ROOF-INSTALL NEW SIGNS ON ROOF FANS-(PA) 9/20/19CMCORRECTCLOSETX0297ZZ-Roof381229TX0297F36A005TX0297ZZ-FAN-01-F36A-59/27/19 10:00 AMNO0763300
19-50340526BASEMENT-2 LIGHTS OUT-(PA) 9/24/19CMCORRECTCLOSETX0297ZZ-Basement381285TX0297F34H002TX0297ZZ-LGI-F34H-29/27/19 10:00 AMNO0763279
19-503405321007-TURN UNIT AHU-10 ON CONSTRUCTION NEEDS TO TEST -(PA) 9/2\4/19CMCORRECTCLOSETX0297ZZ-Floor 10-Room-1007976728TX0297A11A013TX0297ZZ-AHU-01-A11A-139/27/19 10:00 AMNO0790799
19-503405409605-LIGHT OUT IN HALLWAY-(PA) 9/9/19CMCORRECTCLOSETX0211ZZ-Floor 099/27/19 10:00 AMNO0763125
19-503405796TH FL-LIGHT OUT-(PA) 9/9/19CMCORRECTCLOSETX0211ZZ-Floor 069/27/19 10:00 AMNO0763122
19-503405914-SOME LIGHTS OUT-(PA) 9/9/19CMCORRECTCLOSETX0211ZZ-Floor 049/27/19 10:00 AMNO0763120
19-503406018TH FL-LIGHT OUT-(PA) 9/12/19CMCORRECTCLOSETX0211ZZ-Entire Building377352TX0211F34A001TX0211ZZ-LGI-F34A-19/27/19 10:00 AMNO0763115
19-503406057TH FL-LIGHT OUT-(PA) 9/12/19CMCORRECTCLOSETX0211ZZ-Floor 079/27/19 10:00 AMNO0763123
19-503406086TH FL-LIGHT OUT-(PA) 9/12/19CMCORRECTCLOSETX0211ZZ-Entire Building377352TX0211F34A001TX0211ZZ-LGI-F34A-19/27/19 10:00 AMNO0763115
19-5034061611TH FL-SOME AREAS LIGHTS OUT-(PA) 9/12/19CMCORRECTCLOSETX0211ZZ-Floor 119/27/19 10:00 AMNO0763127
19-503407999TH FL-LIGHT OUT BY ELEVATOR-(PA) 9/12/19CMCORRECTCLOSETX0211ZZ-Floor 099/27/19 10:00 AMNO0763125
19-503408535TH FL-LIGHT OUT-(PA) 9/12/19CMCORRECTCLOSETX0211ZZ-Entire Building377352TX0211F34A001TX0211ZZ-LGI-F34A-19/27/19 10:00 AMNO0763115
19-503408594TH FL-LIGHT OUT-(PA) 9/12/19CMCORRECTCLOSETX0211ZZ-Entire Building377352TX0211F34A001TX0211ZZ-LGI-F34A-19/27/19 10:00 AMNO0763115
19-503408622ND FL-LIGHT OUT-(PA) 9/12/19CMCORRECTCLOSETX0211ZZ-Entire Building377352TX0211F34A001TX0211ZZ-LGI-F34A-19/27/19 10:00 AMNO0763115
19-50340871B510-CENTRAL PLANT NEED CLEANING-(PA) 9/13/19CMCORRECTCLOSETX0211ZZ-Basement9/27/19 10:00 AMNO0763114
19-503408939210-HALLWAY LIGHT OUT-(PA) 9/13/19CMCORRECTCLOSETX0211ZZ-Floor 099/27/19 10:00 AMNO0763125
19-5034089711TH FL-LIGHT OUT-(PA) 9/16/19CMCORRECTCLOSETX0211ZZ-Floor 099/27/19 10:00 AMNO0763125
19-503409029TH FL-LIGHT OUT-(PA) 9/16/19CMCORRECTCLOSETX0211ZZ-Entire Building377352TX0211F34A001TX0211ZZ-LGI-F34A-19/27/19 10:00 AMNO0763115
19-503409067TH FL-LIGHT OUT-(PA) 9/16/19CMCORRECTCLOSETX0211ZZ-Floor 079/27/19 10:00 AMNO0763123
19-50340472G-2-RM HAS COBWEBS AND DIRTY FLOOR-(PA) 9/6/19CMCORRECTCLOSETX0297ZZ-Garage9/27/19 10:00 AMNO0763294
19-5034051512TH FL/ROOF-CLEAN SWEEP STAIRWELL PART LEADING TO ROOF ACCESS DOORS-(PA) 9/26/19CMCORRECTCLOSETX0297ZZ-Roof9/27/19 10:00 AMNO0763300
19-5039530511TH FL-LIGHT OUT-(PA) 9/27/19CMCORRECTCLOSETX0211ZZ-Floor 119/30/19 10:00 AMNO0763127
19-503953759TH FL-LIGHT OUT-(PA) 9/27/19CMCORRECTCLOSETX0211ZZ-Floor 099/30/19 10:00 AMNO0763125
19-503953771ST FL-LIGHTS OUT-(PA) 9/27/19CMCORRECTCLOSETX0211ZZ-Entire Building377352TX0211F34A001TX0211ZZ-LGI-F34A-19/30/19 10:00 AMNO0763115
19-50395378B-524-BASE NEED TO BE PAINT-(PA) 9/30/19CMCORRECTCLOSETX0211ZZ-Basement9/30/19 10:00 AMNO0763114
19-503953802301-LIGHT OUT-(PA) 9/30/19CMCORRECTCLOSETX0211ZZ-Entire Building377352TX0211F34A001TX0211ZZ-LGI-F34A-19/30/19 10:00 AMNO0763115
19-503953831ST FL-SEVERAL LIGHTS OUT IN AREA-(PA) 9/20/19CMCORRECTCLOSETX0701HO-Floor 019/30/19 10:00 AMNO0763820
19-5039538410 5TH-AHU 10 NEED TO BE WIPED DOWN-(PA) 9/27/19CMCORRECTCLOSETX0081ZZ-Floor 05375377TX0081A11A013TX0081ZZ-AHU-01-A11A-139/30/19 10:00 AMNO0763008
19-503953856TH FL-AHU 12 NEED TO BE WIPED DOWN-(PA) 9/30/19CMCORRECTCLOSETX0081ZZ-Floor 06375354TX0081A11A002TX0081ZZ-AHU-01-A11A-29/30/19 10:00 AMNO0763009
19-50395387724A/715-AHU 14 AND 16 NEED TO BE WIPED DOWN-(PA) 9/26/819CMCORRECTCLOSETX0081ZZ-Floor 07375364TX0081A11A003TX0081ZZ-AHU-01-A11A-39/30/19 10:00 AMNO0763010
19-50395390405-AHU 8 NEED TO WIPE DOWN-(PA) 9/27/19CMCORRECTCLOSETX0081ZZ-Floor 04-Room-405970771TX0081A11A011TX0081ZZ-AHU-01-A11A-119/30/19 10:00 AMNO0789247
19-503953914TH FL-LIGHTS OUT-(PA) 9/16/19CMCORRECTCLOSETX0211ZZ-Floor 049/30/19 10:00 AMNO0763120
19-5039539512TH FL-SOME LIGHTS OUT AND SOME FLICKERING IN AREA-(PA) 9/16/19CMCORRECTCLOSETX0211ZZ-Floor 129/30/19 10:00 AMNO0763128
19-5039539611TH FL-LIGH TOUT-(PA) 9/19/19CMCORRECTCLOSETX0211ZZ-Floor 119/30/19 10:00 AMNO0763127
19-503953998TH FL-LIGHT OUT IN ELEVATOR LOBBY-(PA) 9/19/19CMCORRECTCLOSETX0211ZZ-Floor 119/30/19 10:00 AMNO0763127
19-503954015218-LIGHTS OUT-(PA) 9/19/19CMCORRECTCLOSETX0211ZZ-Floor 059/30/19 10:00 AMNO0763121
19-5039540411TH FL-SOME AREAS LIGHTS OUT-(PA) 9/20/19CMCORRECTCLOSETX0211ZZ-Floor 119/30/19 10:00 AMNO0763127
19-503954055218J-LIGHTS OUT-(PA) 9/20/19CMCORRECTCLOSETX0211ZZ-Entire Building377352TX0211F34A001TX0211ZZ-LGI-F34A-19/30/19 10:00 AMNO0763115
19-50395406BACK DOCK-LIGHTS OUT-(PA) 9/20/19CMCORRECTCLOSETX0211ZZ-Floor 019/30/19 10:00 AMNO0763117
19-503954080300-MECHANICAL RM NEED CLEANING-(PA) 9/26/19CMCORRECTCLOSETX0211ZZ-Floor 109/30/19 10:00 AMNO0763126
19-50395409B524-DRAIN CLOGGED-(PA) 9/26/19CMCORRECTCLOSETX0211ZZ-Basement9/30/19 10:00 AMNO0763114
19-50395411B202J-LIGHT OUT-(PA) 9/26/19CMCORRECTCLOSETX0211ZZ-Basement9/30/19 10:00 AMNO0763114
19-503954137TH FL-SOME AREAS LIGHTS OUT-(PA) 9/26/19CMCORRECTCLOSETX0211ZZ-Entire Building377352TX0211F34A001TX0211ZZ-LGI-F34A-19/30/19 10:00 AMNO0763115
19-50395415POST OFFICE-VALVE LEAKING-(PA) 9/12/19CMCORRECTCLOSETX0101ZZ-Floor 019/30/19 10:00 AMNO0763018
19-50395417257Q-TOILET SEAT LOOSE-(PA) 9/12/19CMCORRECTCLOSETX0101ZZ-Floor 029/30/19 10:00 AMNO0763019
19-50395418ELEVATOR 2-LIGHT OUT-(PA) 9/13/19CMCORRECTCLOSETX0101ZZ-Entire Building9/30/19 10:00 AMNO0763016
19-50395419127-LIGHT OUT-(PA) 9/13/19CMCORRECTCLOSETX0101ZZ-Entire Building375545TX0101F34A001TX0101ZZ-LGI-F34A-19/30/19 10:00 AMNO0763016
19-503954221ST FL LOBBY-LIGHT COVER HAS BUGS-(PA) 9/18/19CMCORRECTCLOSETX0101ZZ-Floor 019/30/19 10:00 AMNO0763018
19-50395425OUTSIDE 159-LIGHT OUT-(PA) 9/18/19CMCORRECTCLOSETX0101ZZ-Entire Building375540TX0101L03A003TX0101ZZ-LGE-L03A-39/30/19 10:00 AMNO0763016
19-50395427360-LIGHT OUT IN CEREMONY RM-(PA) 9/18/19CMCORRECTCLOSETX0101ZZ-Entire Building375561TX0101F34H004TX0101ZZ-LGI-F34H-49/30/19 10:00 AMNO0763016
19-50395429A256-LIGHT OUT-(PA) 9/23/19CMCORRECTCLOSETX0101ZZ-Floor 029/30/19 10:00 AMNO0763019
19-50395432353 OUTSIDE-LIGHT OUT-(PA) 9/24/19CMCORRECTCLOSETX0101ZZ-Entire Building375561TX0101F34H004TX0101ZZ-LGI-F34H-49/30/19 10:00 AMNO0763016
19-50395434350-LIGHT OUT-(PA) 9/24/19CMCORRECTCLOSETX0101ZZ-Entire Building375561TX0101F34H004TX0101ZZ-LGI-F34H-49/30/19 10:00 AMNO0763016
19-50395437353 INSIDE-LIGHT OUT-(PA) 9/24/19CMCORRECTCLOSETX0101ZZ-Entire Building375561TX0101F34H004TX0101ZZ-LGI-F34H-49/30/19 10:00 AMNO0763016
19-503954403RD FL-LIGHT OUT IN AREAS-(PA) 9/24/19CMCORRECTCLOSETX0101ZZ-Entire Building375561TX0101F34H004TX0101ZZ-LGI-F34H-49/30/19 10:00 AMNO0763016
19-503954412ND FL-MANY LIGHTS OUT IN AREAS-(PA) 9/24/19 RMS 230/217/311CMCORRECTCLOSETX0101ZZ-Entire Building375561TX0101F34H004TX0101ZZ-LGI-F34H-49/30/19 10:00 AMNO0763016
19-50395443140-OUTLET COVER IS BROKEN-(PA) 9/25/19CMCORRECTCLOSETX0101ZZ-Floor 019/30/19 10:00 AMNO0763018
19-50395446B37A-FLUSH VALVE LEKAING AT VACUUM BREAKER-(PA) 9/25/19CMCORRECTCLOSETX0101ZZ-Basement9/30/19 10:00 AMNO0763015
19-50395448FRONT DOOR-NOT WORKING-(PA) 9/26/19CMCORRECTCLOSETX0101ZZ-Floor 019/30/19 10:00 AMNO0763018
19-50454481P077KETX0701HSTN1 - LaBranch FB, Houston TX:io16_2 / Tangent_Alarm Timestamp: 03-Oct-19 1:24:03 AM UTC State: Offnormal Text: Tangent Down/ Fault-(EMAIL) 10/3/19CMCORRECTCLOSETX0701HO-Entire Building10/3/19 10:00 AMNO0763818
19-50454488P077KETX0701HSTN1 - LaBranch FB, Houston TX:Chillers / ChwS_Temp_Alm Timestamp: 03-Oct-19 1:33:52 AM UTC State: Offnormal Text: Chillers didn't bring temp below 60F in 15 mins-(EMAIL) 10/3/19CMEQFAILCLOSETX0701HO-Entire Building10/3/19 10:00 AMNO0763818
19-50455693215-LIGHT OUT IN AREA-(PA) 10/2/19CMCORRECTCLOSETX0081ZZ-Entire Building375458TX0081F34A002TX0081ZZ-LGI-F34A-210/3/19 10:00 AMNO0763002
19-50455709PLANT-CWP #1-NEED TO PAINT PAD-(PA) 10/2/19CMCORRECTCLOSETX0081ZZ-Basement-Central Plant970841TX0081P04A003TX0081ZZ-PMP-06-P04A-310/3/19 10:00 AMNO0789227
19-50455713PLANT-CWP #2 NEED TO PAINT PAD-(PA) 10/12/19CMCORRECTCLOSETX0081ZZ-Basement-Central Plant970846TX0081P04A004TX0081ZZ-PMP-06-P04A-410/3/19 10:00 AMNO0789227
19-50455718209-LIGHT OUT-(PA) 10/2/19CMCORRECTCLOSETX0081ZZ-Entire Building375458TX0081F34A002TX0081ZZ-LGI-F34A-210/3/19 10:00 AMNO0763002
19-50455721PLANT-BOILER #2 GAUGE INSERT CONNECTION-(PA) 10/1/19CMCORRECTCLOSETX0081ZZ-Basement-Central Plant10/3/19 10:00 AMNO0789227
19-504557223627-LIGHT FIXTURE COVER HANGING-(PA) 10/1/19CMCORRECTCLOSETX0081ZZ-Entire Building375463TX0081F34A003TX0081ZZ-LGI-F34A-310/3/19 10:00 AMNO0763002
19-50493185P077KETX0081GVTN1 - Galveston, TX:Chillers / ChwS_Temp_Alm Timestamp: 08-Oct-19 5:49:03 AM UTC State: Offnormal Text: Chillers didn't bring temp below 60F in 30 min-(EMAIL) 10/8/19CMEQFAILCLOSETX0081ZZ-Basement-Central Plant970825TX0081R07A001TX0081ZZ-CHL-S1-R07A-110/8/19 7:45 AMNO0789227
19-50493380P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:P077KETX0298HSTN8:AHU15_FanStatus Timestamp: 07-Oct-19 5:55:39 PM UTC State: Offnormal Text: P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:P077KETX0298HSTN8:AHU15_FanStatus is in Alarm-(EMAIL) 10/8/19CMEQFAILCLOSETX0298ZZ-Entire Building10/8/19 10:00 AMNO0763303
19-50493441P077KETX0701HSTN1 - LaBranch FB, Houston TX:Chillers / ChwS_Temp_Alm Timestamp: 06-Oct-19 11:57:05 PM UTC State: Offnormal Text: Chillers didn't bring temp below 60F in 15 mins-(EMAIL) 10/8/19CMEQFAILCLOSETX0701HO-Entire Building10/8/19 10:00 AMNO0763818
19-50493450P077KETX0701HSTN1 - LaBranch FB, Houston TX:io16_2 / Tangent_Alarm Timestamp: 06-Oct-19 11:47:16 PM UTC State: Offnormal Text: Tangent Down/ Fault-(EMAIL) 10/8/19CMEQFAILCLOSETX0701HO-Entire Building10/8/19 10:00 AMNO0763818
19-50493458P077KETX0081GVTN1 - Galveston, TX:Chillers / ChwS_Temp_Alm Timestamp: 05-Oct-19 5:05:16 AM UTC State: Offnormal Text: Chillers didn't bring temp below 60F in 30 mins-(EMAIL) 10/8/19CMCORRECTCLOSETX0081ZZ-Basement-Central Plant970825TX0081R07A001TX0081ZZ-CHL-S1-R07A-110/8/19 10:00 AMNO0789227
19-50493414P077KETX0211HSTN1 - Bob Casey CH, Houston TX:CHWP2_FaultCHWP2 Timestamp: 07-Oct-19 11:11:28 AM UTC State: Offnormal Text: Alarm Active!!-(EMAIL) 10/8/19CMEQFAILCLOSETX0211ZZ-Entire Building10/8/19 11:42 AMNO0763115
19-50551319P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:RA_Humidity Timestamp: 10-Oct-19 11:55:19 PM UTC State: Offnormal Text: P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:RA_Humidity is above 60 %RH-(EMAIL) 10/11/19CMEQFAILCLOSETX0298ZZ-Basement381604TX0298R17C001TX0298ZZ-CHL-MB2-R17B00110/11/19 7:00 AMNO0763302
19-50556754P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:P077KETX0298HSTN1:Chiller1Alarm Timestamp: 10-Oct-19 11:52:41 PM UTC State: Offnormal-(EMAIL) 10/11/19CMEQFAILCLOSETX0298ZZ-Basement381604TX0298R17C001TX0298ZZ-CHL-MB2-R17B00110/11/19 7:00 AMNO0763302
19-51300163P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:AHU2_HighStaticPressure Timestamp: 15-Oct-19 4:46:17 PM UTC State: Offnormal Text: P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:AHU2_HighStaticPressure is in Alarm-(EMAIL) 10/15/19CMEQFAILCLOSETX0298ZZ-Floor 02381506TX0298A11A009TX0298ZZ-AHU-01-A11A00910/15/19 1:18 PMNO0763306
19-51376968P077KETX0701HSTN1 - LaBranch FB, Houston TX:io16_2 / Tangent_Alarm Timestamp: 15-Oct-19 9:23:42 PM UTC State: Offnormal Text: Tangent Down/ Fault-(EMAIL) 10/16/19CMEQFAILCLOSETX0701HO-Entire Building10/16/19 10:00 AMNO0763818
19-51377008P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:P077KETX0298HSTN1:Chiller3Alarm Timestamp: 15-Oct-19 11:08:06 PM UTC State: Offnormal-(EMAIL) 10/16/19CMCORRECTCLOSETX0298ZZ-Entire Building10/16/19 10:00 AMNO0763303
19-51377036P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:RA_Humidity Timestamp: 15-Oct-19 11:36:28 PM UTC State: Offnormal Text: P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:RA_Humidity is above 60 %RH-(EMAIL) 10/16/19CMEQFAILCLOSETX0298ZZ-Basement381604TX0298R17C001TX0298ZZ-CHL-MB2-R17B00110/16/19 10:00 AMNO0763302
19-51377078P077KETX0701HSTN1 - LaBranch FB, Houston TX:Chillers / ChwS_Temp_Alm Timestamp: 15-Oct-19 9:33:19 PM UTC State: Offnormal Text: Chillers didn't bring temp below 60F in 15 mins-(EMAIl) 10/16/19CMEQFAILCLOSETX0701HO-Entire Building10/16/19 10:00 AMNO0763818
19-51377661GARAGE-ENTRANCE GATE NOT FUNCTIONING-(PA) 10/5/19CMCORRECTCLOSETX0297ZZ-Exterior-Outside976874TX0297G03B001TX0297ZZ-FNG-G03B-110/16/19 10:00 AMNO0790688
19-51377669GARAGE-CONDUIT FROM RED PUSH BUTTON TO EXIT GATE CONTROLLER IS BROKE-(PA) 10/5/19CMCORRECTCLOSETX0297ZZ-Exterior-Outside976874TX0297G03B001TX0297ZZ-FNG-G03B-110/16/19 10:00 AMNO0790688
19-51377686GARAGE-CONDUIT FROM GESSNER ENTRANCE CARD READER TO CONTROL NOT SECURED-(PA) 10/5/19CMCORRECTCLOSETX0297ZZ-Exterior-Outside976874TX0297G03B001TX0297ZZ-FNG-G03B-110/16/19 10:00 AMNO0790688
19-513776925218J-SOME LIGHTS OUT-(PA) 9/20/19CMCORRECTCLOSETX0211ZZ-Entire Building377352TX0211F34A001TX0211ZZ-LGI-F34A-110/16/19 10:00 AMNO0763115
19-513776993RD FL-HALLWAY LIGHT OUT-(PA) 10/2/19CMCORRECTCLOSETX0211ZZ-Entire Building377352TX0211F34A001TX0211ZZ-LGI-F34A-110/16/19 10:00 AMNO0763115
19-5137770211B-LIGHT OUT-(PA) 10/4/19CMCORRECTCLOSETX0211ZZ-Floor 1110/16/19 10:00 AMNO0763127
19-513777099TH FL-LIGHT OUT IN HALLWAY-(PA) 10/4/19CMCORRECTCLOSETX0211ZZ-Floor 0910/16/19 10:00 AMNO0763125
19-513779082ND FL-LIGHT OUT-(PA) 10/4/19CMCORRECTCLOSETX0211ZZ-Floor 0210/16/19 10:00 AMNO0763118
19-5137792210TH FL-SOUTH STAIRWAY LIGHT OUT-(PA) 10/2/19CMCORRECTCLOSETX0211ZZ-Entire Building377352TX0211F34A001TX0211ZZ-LGI-F34A-110/16/19 10:00 AMNO0763115
19-513779308TH FL-LIGHT OUT STAIRWAY SOUTH-(PA) 10/7/19CMCORRECTCLOSETX0211ZZ-Entire Building377352TX0211F34A001TX0211ZZ-LGI-F34A-110/16/19 10:00 AMNO0763115
19-513779457TH FL-SOUTH STAIRWAY LIGHT OUT-(PA) 10/7/19CMCORRECTCLOSETX0211ZZ-Entire Building377352TX0211F34A001TX0211ZZ-LGI-F34A-110/16/19 10:00 AMNO0763115
19-51377953R515-LIGHT OUT-(PA) 9/11/19CMCORRECTCLOSETX0081ZZ-Entire Building375473TX0081F34A005TX0081ZZ-LGI-F34A-510/16/19 10:00 AMNO0763002
19-51377968GENERATOR RM-NEED TO CLEAN GENERATOR RM-(PA) 9/13/19CMCORRECTCLOSETX0081ZZ-Entire Building10/16/19 10:00 AMNO0763002
19-51377973OUTSIDE-FLAG NEEDS TO BE REPLACED-(PA) 9/13/19CMCORRECTCLOSETX0081ZZ-Exterior10/16/19 10:00 AMNO0763003
19-51377988PLANT-NEED TO BE CLEANED-(PA) 9/13/19CMCORRECTCLOSETX0081ZZ-Entire Building10/16/19 10:00 AMNO0763002
19-513779977TH FL MRR-COLD SIDE FAUCET FROZE-(PA) 9/13/19CMCORRECTCLOSETX0081ZZ-Floor 0710/16/19 10:00 AMNO0763010
19-51378008201-LIGHTS OUT-(PA) 9/16/19CMCORRECTCLOSETX0081ZZ-Entire Building375458TX0081F34A002TX0081ZZ-LGI-F34A-210/16/19 10:00 AMNO0763002
19-513780156113-WATER CLOSER CONSTANTLY RUNNING-(PA) 9/23/19CMCORRECTCLOSETX0081ZZ-Floor 0610/16/19 10:00 AMNO0763009
19-513780265TH FL MRR-URINAL CONSTANTLY RUNS-(PA) 9/24/19CMCORRECTCLOSETX0081ZZ-Floor 0510/16/19 10:00 AMNO0763008
19-513780333RD FL MRR-URINAL CLOGGED-(PA) 9/24/19CMCORRECTCLOSETX0081ZZ-Floor 0310/16/19 10:00 AMNO0763006
19-513780345TH FL HALLWAY-LIGHT OUT-(PA) 9/23/19CMCORRECTCLOSETX0081ZZ-Exterior-Outside970837TX0081L04A005TX0081ZZ-LGE-L04A-510/16/19 10:00 AMNO0789230
19-51378043508-LIGHT OUT-(PA) 9/23/19CMCORRECTCLOSETX0081ZZ-Entire Building375473TX0081F34A005TX0081ZZ-LGI-F34A-510/16/19 10:00 AMNO0763002
19-51378045TH FL CRTRM-LIGHT OUT-(PA) 9/23/19CMCORRECTCLOSETX0081ZZ-Entire Building375473TX0081F34A005TX0081ZZ-LGI-F34A-510/16/19 10:00 AMNO0763002
19-513780505TH FL MRR-URINAL LEAKS AT STOP VALVE-(PA) 9/24/19CMCORRECTCLOSETX0081ZZ-Floor 0510/16/19 10:00 AMNO0763008
19-513780613RD FL MRR-MOP SINK CLOGGED-(PA) 9/24/19CMCORRECTCLOSETX0081ZZ-Floor 0310/16/19 10:00 AMNO0763006
19-51378066GENERATOR RM-AREA NEED TO BE CLEANED-(PA) 9/24/19CMCORRECTCLOSETX0081ZZ-Entire Building10/16/19 10:00 AMNO0763002
19-51378084PLANT-COMPRESSOR COVER NEED TO BE REINSTALLED CHILLER #2-(PA) 9/26/19CMCORRECTCLOSETX0081ZZ-Basement-Central Plant970825TX0081R07A001TX0081ZZ-CHL-S1-R07A-110/16/19 10:00 AMNO0789227
19-51378096PLANT-EQUIPMENT NEEDED TO BE WIPED DOWN-(PA) 9/26/19CMCORRECTCLOSETX0081ZZ-Basement-Central Plant970825TX0081R07A001TX0081ZZ-CHL-S1-R07A-110/16/19 10:00 AMNO0789227
19-51378102PLAN T-EQUIPMENT NEEDED TO BE WIPE DOWN-(PA) 9/26/19CMCORRECTCLOSETX0081ZZ-Floor 07-Mechanical Equipment Room970781TX0081A11A018TX0081ZZ-AHU-01-A11A-1810/16/19 10:00 AMNO0789254
19-51378110735-OAHU 1 NEED TO BE WIPED DOWN-(PA) 9/26/19CMCORRECTCLOSETX0081ZZ-Floor 07-Mechanical Equipment Room970781TX0081A11A018TX0081ZZ-AHU-01-A11A-1810/16/19 10:00 AMNO0789254
19-51378115724A-AHU15 NEED TO BE WIPE DOWN-(PA) 9/26/19CMCORRECTCLOSETX0081ZZ-Floor 07375369TX0081A11A004TX0081ZZ-AHU-01-A11A-410/16/19 10:00 AMNO0763010
19-51378123215-LIGHT OUT N AREA-(PA) 10/2/19CMCORRECTCLOSETX0081ZZ-Entire Building375458TX0081F34A002TX0081ZZ-LGI-F34A-210/16/19 10:00 AMNO0763002
19-51378126PLNAT-CWP#1 NEED TO BE PAINTED-(PA) 10/2/19CMCORRECTCLOSETX0081ZZ-Basement-Central Plant970841TX0081P04A003TX0081ZZ-PMP-06-P04A-310/16/19 10:00 AMNO0789227
19-51378132PLANT-CWP #2 NEED TO PAINT PAD-(PA) 10/2/19CMCORRECTCLOSETX0081ZZ-Basement-Central Plant970846TX0081P04A004TX0081ZZ-PMP-06-P04A-410/16/19 10:00 AMNO0789227
19-51378144209-LIGHT OUT-(PA) 10/2/19CMCORRECTCLOSETX0081ZZ-Entire Building375458TX0081F34A002TX0081ZZ-LGI-F34A-210/16/19 10:00 AMNO0763002
19-51378149PLNAT-CHILLER 1 NEED TO PAINT PAD-(PA) 10/8/19CMCORRECTCLOSETX0081ZZ-Entire Building1289584TX0081F07A002TX0081ZZ-FPM-01-128958410/16/19 10:00 AMNO0763002
19-51378155PLANT-CHILLER 2 NEED TO PAINT PAD-(PA) 10/8/19CMCORRECTCLOSETX0081ZZ-Basement-Central Plant970825TX0081R07A001TX0081ZZ-CHL-S1-R07A-110/16/19 10:00 AMNO0789227
19-51378162217-A/C NOT COOLING TEMP WILL NOT DROP LOWER THAN 78-(PA) 10/8/19CMCORRECTCLOSETX0081ZZ-Floor 05-Room-515970794TX0081A13A002TX0081ZZ-ACU-A13A-210/16/19 10:00 AMNO0789252
19-513781718TH FL MRR-SINK HAS TOO MUCH POWER WHEN WATER ON-(PA) 9/16/19CMCORRECTCLOSETX0435HF-Floor 0810/16/19 10:00 AMNO0763574
19-513782118TH FL MRR-LOOSE TOILET SEAT-(PA) 9/16/19CMCORRECTCLOSETX0435HF-Floor 0810/16/19 10:00 AMNO0763574
19-513782226TH FL MRR-LIGHT OUT-(PA) 9/16/19CMCORRECTCLOSETX0435HF-Floor 0610/16/19 10:00 AMNO0763572
19-51378232OUTSIDE BLDG-DIESEL FUEL MONITOR HAS ALARM ON TANK #3-(PA) 9/18/19CMCORRECTCLOSETX0435HF-Exterior-Outside981852TX0435T03A005TX0435HF-TNK-01-T03A-510/16/19 10:00 AMNO0792205
19-513782402ND FL-DOUBLE GLASS DOORS MAKING NOISE WHEN OPEN-(PA) 9/18/19CMCORRECTCLOSETX0435HF-Entire Building-Entrance981817TX0435D05A001TX0435HF-PDR-D05A-110/16/19 10:00 AMNO0792202
19-513782997TH FL MRR-SOAP DISPENSER ISNT WORKING PROPERLY-(PA) 9/18/19CMCORRECTCLOSETX0435HF-Floor 0710/16/19 10:00 AMNO0763573
19-513783057TH FL-LOBBY LIGHT OUT-(PA) 9/18/19CMCORRECTCLOSETX0435HF-Floor 0710/16/19 10:00 AMNO0763573
19-513783117TH FL LRR-LIGHT OUT-(PA) 9/18/19CMCORRECTCLOSETX0435HF-Floor 0710/16/19 10:00 AMNO0763573
19-513783211ST FL-SOME LIGHT OUT IN AREAS-(PA) 9/20/19CMCORRECTCLOSETX0701HO-Floor 0110/16/19 10:00 AMNO0763820
19-513783411ST FL-DEAD RODENT ABOVE CEILING GRID-(PA) 9/25/19CMCORRECTCLOSETX0298ZZ-Floor 0110/16/19 10:00 AMNO0763305
19-51378344GARAGE-PARKING GARAGE LIGHT OUT IN GREY ST-(PA) 9/23/19CMCORRECTCLOSETX0298ZZ-Garage10/16/19 10:00 AMNO0763327
19-513780772ND FL MRR-WATER ON FLOOR-(PA) 9/266/19CMCORRECTCLOSETX0081ZZ-Floor 0210/16/19 10:15 AMNO0763005
19-513783321ST FL-CONFERENCE RM WATER ON FLOOR AROUND WINDOW-(PA) 9/25/19CMCORRECTCLOSETX0298ZZ-Floor 0110/16/19 10:15 AMNO0763305
19-51597391ELEVATOR 3-STOPPED ON 4 BOUNCED THEN OPEN DOORS-(ADAN 30) 1025/19CMEQFAILCLOSETX0298ZZ-Entire Building10/25/19 1:30 PMNO0763303
19-51746691BLDG,P07QMETX0019BMT1 - Beaumont TX:Points / Twr1IsoAlarm -Tower Faulted!! (GSA/BAS)CMEQFAILCLOSETX0019ZZ-J BROOKS FEDERAL BLDG11/1/19 3:30 AMNO0761252
19-51746668BLDG., P077KETX0701HSTN1 - LaBranch FB, Houston TX:io16_2 / Tangent_Alarm ; Tangent Down/ Fault (GSA.BAS)CMEQFAILCLOSETX0701HO-LABRANCH FEDERAL BLDG11/1/19 9:00 AMNO0760648
19-51747073BLDG, P07QMETX0019BMT1 - Beaumont TX:Points / Twr2IsoAlarm - - Tower Faulted!! (GSA/BAS)CMEQFAILCLOSETX0019ZZ-J BROOKS FEDERAL BLDG11/1/19 2:00 PMNO0761252
19-51746906BLDG, P077KETX0701HSTN1 - LaBranch FB, Houston TX:io16_2 / Tangent_Alarm - - Tangent Down/ Fault (GSA/BAS)CMEQFAILCLOSETX0701HO-LABRANCH FEDERAL BLDG11/1/19 2:00 PMNO0760648
19-51747219BLDG,P077KETX0211HSTN1 - Bob Casey CH, Houston TX:Boiler_Plant / HwS_Temp_Alm - -Boiler didn't bring temp above 90F in 60 mins (GSA/BAS)CMEQFAILCLOSETX0211ZZ-Basement-Room-B-202A972723TX0211B02F001TX0211ZZ-BLR-HW4-97272311/1/19 2:00 PMNO0789650
19-51747873BLDG, P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:P077KETX0298HSTN4:Lvl5_IDF_RmTemp is above 75.0 °F Temp - - (GSA/BAS)CMEQFAILCLOSETX0298ZZ-Floor 05381539TX0298A09A002TX0298ZZ-ACC-A09A00211/1/19 2:15 PMNO0763309
19-51748006BLDG, P077KETX0081GVTN1 - Galveston, TX:Chillers / ChwS_Temp_Alm -- Chillers didn't bring temp below 60F in 30 mins (GSA/BAS)CMEQFAILCLOSETX0081ZZ-Basement-Central Plant970825TX0081R07A001TX0081ZZ-CHL-S1-R07A-111/1/19 2:15 PMNO0789227
19-51748270P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:RA_Humidity is above 60 %RH - (GSA/BAS)CMEQFAILCLOSETX0298ZZ-Basement381604TX0298R17C001TX0298ZZ-CHL-MB2-R17B00111/1/19 2:15 PMNO0763302
19-51748377P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:P077KETX0298HSTN13:OAHU1_FanStatus - -FanStatus is in Alarm (GSA/BAS)CMEQFAILCLOSETX0298ZZ-Penthouse-Mechanical Equipment Room977145TX0298A11C016TX0298ZZ-AHU-01-A11C01611/1/19 2:15 PMNO0791010
19-51748648BLDG, P077KETX0081GVTN1 - Galveston, TX:Chillers / ChwS_Temp_Alm - -Chillers didn't bring temp below 60F in 30 mins (GSA/BAS)CMEQFAILCLOSETX0081ZZ-Basement-Central Plant970783TX0081R07A002TX0081ZZ-CHL-S1-R07A-211/1/19 2:15 PMNO0789227
19-51770453BLDG., P077KETX0701HSTN1 - LaBranch FB, Houston TX:io16_2 / Tangent_Alarm Timestamp: 02-Nov-19 1:01:13 PM UTC State: Offnormal Text: Tangent Down/ Fault (GSA/BAS)CMEQFAILCLOSETX0701HO-LABRANCH FEDERAL BLDG11/2/19 9:15 AMNO0760648
19-51770462BLDG., P077KETX0211HSTN1 - Bob Casey CH, Houston TX:Boiler_Plant / HwS_Temp_Alm Timestamp: 02-Nov-19 1:07:03 PM UTC State: Offnormal Text: Boiler didn't bring temp above 90F in 60 mins (BAS/GSA)CMEQFAILCLOSETX0211ZZ-B CASEY COURTHOUSE11/2/19 9:15 AMNO0761266
19-51770475BLDG., P077KETX0701HSTN1 - LaBranch FB, Houston TX:io16_2 / Tangent_Alarm Timestamp: 04-Nov-19 2:01:14 PM UTC State: Offnormal Text: Tangent Down/ Fault (GAS/BAS)CMEQFAILCLOSETX0701HO-LABRANCH FEDERAL BLDG11/4/19 9:15 AMNO0760648
19-51770478BLDG., P077KETX0101HSTN1 - Customs House (Houston Texas):Basement MBB_5 Has Lost Communications (GSA.BAS)CMEQFAILCLOSETX0101ZZ-HOUSTON CUSTOMS HOUSE11/4/19 9:15 AMNO0761257
19-51803643Source: P077KETX0701HSTN1 - LaBranch FB, Houston TX:io16_2 / Tangent_Alarm Timestamp: 06-Nov-19 2:01:14 PM UTC State: Offnormal Text: Tangent Down/ Fault (GSA/BAS) NCCMEQFAILCLOSETX0701HO-LABRANCH FEDERAL BLDG11/6/19 9:15 AMNO0760648
19-51803719Source: P077KETX0701HSTN1 - LaBranch FB, Houston TX:io16_2 / Tangent_Alarm Timestamp: 06-Nov-19 2:01:14 PM UTC State: Offnormal Text: Tangent Down/ Fault (GSA/BAS) NCCMEQFAILCLOSETX0701HO-LABRANCH FEDERAL BLDG11/6/19 12:15 PMNO0760648
19-51809364BLDG., Source: P077KETX0081GVTN1 - Galveston, TX:Chillers / ChwS_Temp_Alm Timestamp: 07-Nov-19 2:18:29 AM UTC State: Offnormal Text: Chillers didn't bring temp below 60F in 30 mins (BAS/GSA) NCCMSERVCALLCLOSETX0081ZZ-Basement-Central Plant970783TX0081R07A002TX0081ZZ-CHL-S1-R07A-211/6/19 9:15 PMNO0789227
19-51889471P077KETX0701HSTN1 - LaBranch FB, Houston TX:io16_2 / Tangent_Alarm Timestamp: 14-Nov-19 2:01:14 PM UTC State: Offnormal Text: Tangent Down/ Fault-(EMAIL) 11/14/19CMEQFAILCLOSETX0701HO-Entire Building11/14/19 5:45 PMNO0763818
19-51889473P077KETX0101HSTN1 - Customs House (Houston Texas):Basement Ahu4 Timestamp: 14-Nov-19 6:02:05 AM UTC State: Offnormal Text: P077KETX0101HSTN1 - Customs House (Houston Texas):Basement Ahu4 Has Lost Communications-(EMAIL) 11/14/19CMEQFAILCLOSETX0101ZZ-Entire Building11/14/19 5:45 PMNO0763016
19-51889480P077KETX0101HSTN1 - Customs House (Houston Texas):Basement MBB_8 Timestamp: 13-Nov-19 4:24:35 PM UTC State: Offnormal Text: P077KETX0101HSTN1 - Customs House (Houston Texas):Basement MBB_8 Has Lost Communications-(EMAIL) 11/14/19CMEQFAILCLOSETX0101ZZ-Entire Building11/14/19 5:45 PMNO0763016
19-51889494P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:P077KETX0298HSTN13:OAHU1_FanStatus Timestamp: 13-Nov-19 8:29:50 PM UTC State: Offnormal Text: P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:P077KETX0298HSTN13:OAHU1_FanStatus is in Alarm-(EMAIL) 11/14/19CMEQFAILCLOSETX0298ZZ-Penthouse-Mechanical Equipment Room977145TX0298A11C016TX0298ZZ-AHU-01-A11C01611/14/19 5:45 PMNO0791010
19-51889499P077KETX0101HSTN1 - Customs House (Houston Texas):Basement Ahu4 Timestamp: 13-Nov-19 4:22:27 PM UTC State: Offnormal Text: P077KETX0101HSTN1 - Customs House (Houston Texas):Basement Ahu4 Has Lost Communications-(EMAIL) 11/14/19CMEQFAILCLOSETX0101ZZ-Entire Building11/14/19 6:00 PMNO0763016
19-51889500P077KETX0101HSTN1 - Customs House (Houston Texas):Basement MBB_10 Timestamp: 13-Nov-19 4:23:59 PM UTC State: Offnormal Text: P077KETX0101HSTN1 - Customs House (Houston Texas):Basement MBB_10 Has Lost Communications-(EMAIL) 11/14/19CMEQFAILCLOSETX0101ZZ-Entire Building11/14/19 6:00 PMNO0763016
19-51889501P077KETX0101HSTN1 - Customs House (Houston Texas):Basement MBB_13 Timestamp: 13-Nov-19 4:25:23 PM UTC State: Offnormal Text: P077KETX0101HSTN1 - Customs House (Houston Texas):Basement MBB_13 Has Lost Communications-(EMAIL) 11/14/19CMEQFAILCLOSETX0101ZZ-Entire Building11/14/19 6:00 PMNO0763016
19-51889504P077KETX0101HSTN1 - Customs House (Houston Texas):Basement MBB_15 Timestamp: 13-Nov-19 4:23:35 PM UTC State: Offnormal Text: P077KETX0101HSTN1 - Customs House (Houston Texas):Basement MBB_15 Has Lost Communications-(EMAIL) 11/14/19CMEQFAILCLOSETX0101ZZ-Entire Building11/14/19 6:00 PMNO0763016
19-52760254Source: P077KETX0081GVTN1 - Galveston, TX:Chillers / ChwS_Temp_Alm Timestamp: 20-Nov-19 2:21:32 AM UTC State: Offnormal Text: Chillers didn't bring temp below 60F in 30 mins (GSA/BAS) NCCMEQFAILCLOSETX0081ZZ-Basement-Central Plant970825TX0081R07A001TX0081ZZ-CHL-S1-R07A-111/19/19 9:30 PMNO0789227
19-52879137Source: P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:Pim_Ahu Static Pressure Timestamp: 22-Nov-19 3:24:13 PM UTC State: Offnormal Text: P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:Pim_Ahu Static Pressure is above 1.00 in/wc-(email) 11/22/19CMEQFAILCLOSETX0298ZZ-Floor 02381506TX0298A11A009TX0298ZZ-AHU-01-A11A00911/22/19 12:00 PMNO0763306
19-52880128P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:AHU2_HighStaticPressure Timestamp: 22-Nov-19 5:30:40 PM UTC State: Offnormal Text: P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:AHU2_HighStaticPressure is in Alarm-(EMAIL) 11/22/19CMEQFAILCLOSETX0298ZZ-Floor 02381506TX0298A11A009TX0298ZZ-AHU-01-A11A00911/22/19 12:00 PMNO0763306
19-52881532P077KETX0081GVTN1 - Galveston, TX:Chillers / ChwS_Temp_Alm Timestamp: 22-Nov-19 2:26:48 AM UTC State: Offnormal Text: Chillers didn't bring temp below 60F in 30 mins-(EMAIL) 11/22/19CMEQFAILCLOSETX0081ZZ-Basement-Central Plant970825TX0081R07A001TX0081ZZ-CHL-S1-R07A-111/22/19 12:00 PMNO0789227
19-52903518P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:P077KETX0298HSTN1:Chiller1Alarm Timestamp: 22-Nov-19 5:17:37 PM CST State: OffnormalCMEQFAILCLOSETX0298ZZ-Basement381604TX0298R17C001TX0298ZZ-CHL-MB2-R17B00111/22/19 6:55 PMNO0763302
19-52943043P07QMETX0019BMT1 - Beaumont TX:Boilers / HwS_Temp_Alm1 Timestamp: 24-Nov-19 12:34:28 PM CST State: Offnormal Text: Boiler didn't bring temp above 90F in 60 mins-(EMAIL) 11/26/19CMEQFAILCLOSETX0019ZZ-Basement-Boiler Mechanical Room969114TX0019B02F001TX0019ZZ-BLR-HW1-B02F-111/26/19 11:00 AMNO0788894
19-52943018P077KETX0081GVTN1 - Galveston, TX:Chillers / ChwS_Temp_Alm Timestamp: 25-Nov-19 8:11:41 PM CST State: Offnormal Text: Chillers didn't bring temp below 60F in 30 mins-(EMAIL) 11/26/19CMEQFAILCLOSETX0081ZZ-Basement-Central Plant970825TX0081R07A001TX0081ZZ-CHL-S1-R07A-111/26/19 11:00 AMNO0789227
19-52943035P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:P077KETX0298HSTN1:Chiller3Alarm Timestamp: 25-Nov-19 5:27:40 PM CST State: Offnormal-(EMAIL) 11/26/19CMEQFAILCLOSETX0298ZZ-Entire Building11/26/19 11:00 AMNO0763303
19-52943055P077KETX0211HSTN1 - Bob Casey CH, Houston TX:Boiler_Plant / HwS_Temp_Alm Timestamp: 24-Nov-19 6:00:36 AM CST State: Offnormal Text: Boiler didn't bring temp above 90F in 60 mins-(EMAIL) 11/26/19CMEQFAILCLOSETX0211ZZ-Entire Building11/26/19 11:00 AMNO0763115
19-52949369BLDG., Source: P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:RA_Humidity Timestamp: 26-Nov-19 5:52:24 PM CST State: Offnormal Text: P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:RA_Humidity is above 60 %RH (GSA/BAS) NCCMEQFAILCLOSETX0298ZZ-GT LELAND FEDERAL BLDG11/26/19 6:45 PMNO0761276
19-52949156Source: P077KETX0081GVTN1 - Galveston, TX:Chillers / ChwS_Temp_Alm Timestamp: 26-Nov-19 8:54:43 PM CST State: Offnormal Text: Chillers didn't bring temp below 60F in 30 mins (GSA/BAS) NCCMEQFAILCLOSETX0081ZZ-Basement-Central Plant970825TX0081R07A001TX0081ZZ-CHL-S1-R07A-111/26/19 10:00 PMNO0789227
19-52959797P077KETX0081GVTN1 - Galveston, TX:Chillers / ChwS_Temp_Alm Timestamp: 27-Nov-19 3:24:42 PM CST State: Offnormal Text: Chillers didn't bring temp below 60F in 30 mins-(EMAIL) 11/27/19CMEQFAILCLOSETX0081ZZ-Basement-Central Plant970825TX0081R07A001TX0081ZZ-CHL-S1-R07A-111/27/19 12:00 PMNO0789227
19-52959800P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:P077KETX0298HSTN3:Pim_Ahu Fan-4 Status Fail Timestamp: 27-Nov-19 9:23:47 AM CST State: Offnormal Text: 4th Floor P077KETX0298HSTN2 - Mickey Leland FB, Houston TX:P077KETX0298HSTN3:Pim_Ahu Fan-4 Status Fail is in Alarm-(EMAIL) 11/27/19CMEQFAILCLOSETX0298ZZ-Floor 041285880TX0298A11A016TX0298ZZ-AHU-01-128588011/27/19 12:00 PMNO0763308
19-530684151ST FL-BACK ENTRY GLASS DOOR SLAMMING CLOSE-(PA) 11/13/19CMCORRECTCLOSETX0101ZZ-Floor 01375534TX0101D05A007TX0101ZZ-DOR-D05A-711/29/19 10:00 AMNO0763018
19-5308359121ST FL-URINAL CLOGGED-(PA) 11/21/19CMCORRECTCLOSETX0298ZZ-Floor 2111/29/19 10:00 AMNO0763324
19-53061412OUTSIDE 221-LIGHT OUT IN HALLWAY-(PA) 11/5/19CMCORRECTCLOSETX0019ZZ-Floor 0212/2/19 10:00 AMNO0762923
19-53062499LOBBY-UPDATE DIRECTORY-(PA) 11/5/19CMCORRECTCLOSETX0019ZZ-Floor 0112/2/19 10:00 AMNO0762922
19-53078191116-LIGHT OUT-(PA) 11/18/19CMCORRECTCLOSETX0019ZZ-Floor 0112/2/19 10:00 AMNO0762922
19-53079239JURY RM-DOOR CLOSING TO HARD-(PA) 11/18/19CMCORRECTCLOSETX0019ZZ-Floor 0112/2/19 10:00 AMNO0762922
19-53054880LOBBY-NEED TO UPDATE MISSING ALERT POSTERS-(PA) 11/1/19CMCORRECTCLOSETX0081ZZ-Floor 0112/2/19 10:00 AMNO0763004
19-53056629227-LIGHT BLINKING IN HALLWAy-(PA) 11/1/19CMCORRECTCLOSETX0081ZZ-Exterior-Outside970822TX0081L04A002TX0081ZZ-LGE-L04A-212/2/19 10:00 AMNO0789230
19-53057581221-LIGHT BLINKING IN HALLWAY-(PA) 11/1/19CMCORRECTCLOSETX0081ZZ-Exterior-Outside970822TX0081L04A002TX0081ZZ-LGE-L04A-212/2/19 10:00 AMNO0789230
19-53058129509-LIGHT BLINKING IN HALLWAY-(PA) 11/4/19CMCORRECTCLOSETX0081ZZ-Exterior-Outside970837TX0081L04A005TX0081ZZ-LGE-L04A-512/2/19 10:00 AMNO0789230
19-530596091ST FL-ADA DOOR NOT WORKING PROPERLY @ ENTRANCE 1ST FL-(PA) 11/4/19CMCORRECTCLOSETX0081ZZ-Floor 0112/2/19 10:00 AMNO0763004
19-53059984BLDG-NEED ALL CLOCKS TIME CORRECTED-(PA) 11/4/19CMCORRECTCLOSETX0081ZZ-Entire Building12/2/19 10:00 AMNO0763002
19-53060227508-LIGHT BLINKING IN HALLWAY-(PA) 11/4/19CMCORRECTCLOSETX0081ZZ-Exterior-Outside970837TX0081L04A005TX0081ZZ-LGE-L04A-512/2/19 10:00 AMNO0789230
19-53060445515-LIGHT OUT-(PA) 11/4/19CMCORRECTCLOSETX0081ZZ-Entire Building375473TX0081F34A005TX0081ZZ-LGI-F34A-512/2/19 10:00 AMNO0763002
19-53060626402-LIGHT BLINKING IN HALLWAY-(PA) 11/4/19CMCORRECTCLOSETX0081ZZ-Exterior-Outside970837TX0081L04A005TX0081ZZ-LGE-L04A-512/2/19 10:00 AMNO0789230
19-5306091018TH FL-3 LIGHTS OUT IN AREA-(PA) 11/7/19CMCORRECTCLOSETX0298ZZ-Floor 1812/2/19 10:00 AMNO0763321
19-530611562ND FL-TOILET SEATS LOOSE-(PA) 11/7/19CMCORRECTCLOSETX0298ZZ-Floor 2012/2/19 10:00 AMNO0763323
19-53062702BASEMENT-LIGHT OUT IN HALLWAY-(PA) 11/12/19CMCORRECTCLOSETX0211ZZ-Entire Building377352TX0211F34A001TX0211ZZ-LGI-F34A-112/2/19 10:00 AMNO0763115
19-53063168GYM-LIGHT OUT-(PA) 11/12/19CMCORRECTCLOSETX0298ZZ-Basement381604TX0298R17C001TX0298ZZ-CHL-MB2-R17B00112/2/19 10:00 AMNO0763302
19-53063358LRR-LIGHT OUT IN LRR GYM-(PA) 11/12/19CMCORRECTCLOSETX0211ZZ-Basement12/2/19 10:00 AMNO0763114
19-5306362211TH FL-LIGHT OUT-(PA) 11/12/19CMCORRECTCLOSETX0211ZZ-Floor 1112/2/19 10:00 AMNO0763127
19-530651747TH FL-LIGHT OUT HALLWAY-(PA) 11/12/19CMCORRECTCLOSETX0211ZZ-Floor 0712/2/19 10:00 AMNO0763123
19-530653566TH FL-LIGHT OUT IN WAITING AREA-(PA) 11/12/19CMCORRECTCLOSETX0211ZZ-Floor 0612/2/19 10:00 AMNO0763122
19-53067064BASEMENT-LIGHT OUT IN HALLWAY-(PA) 11/12/19CMCORRECTCLOSETX0211ZZ-Entire Building377352TX0211F34A001TX0211ZZ-LGI-F34A-112/2/19 10:00 AMNO0763115
19-53067237GYM-LIGHT OUT OUT IN GYM-(PA) 11/12/19CMCORRECTCLOSETX0211ZZ-Basement12/2/19 10:00 AMNO0763114
19-53067574GYM LRR-LIGHT OUT IN RR-( PA) 11/12/19CMCORRECTCLOSETX0211ZZ-Basement12/2/19 10:00 AMNO0763114
19-5306769311TH FL HALLWAY-LIGHT OUT-(PA) 11/12/19CMCORRECTCLOSETX0211ZZ-Floor 1112/2/19 10:00 AMNO0763127
19-530682367TH FL-LIGHT OUT IN HALLWAY-(PA) 11/12/19CMCORRECTCLOSETX0211ZZ-Floor 0712/2/19 10:00 AMNO0763123
19-53068338TH FL-LIGHT OUT IN WAITING AREA-(PA) 11/12/19CMCORRECTCLOSETX0211ZZ-Floor 0612/2/19 10:00 AMNO0763122
19-5307525222ND FL-TOILET SEAT IS LOOSE IN LADIES RR-(PA) 11/13/19CMCORRECTCLOSETX0298ZZ-Floor 2212/2/19 10:00 AMNO0763325
19-5307540920TH FL-TOILET SEAT IS LOOSE IN MEN RR-(PA) 11/13/19CMCORRECTCLOSETX0298ZZ-Floor 2012/2/19 10:00 AMNO0763323
19-5307557319TH FL-RRS TOILET SEATS LOOSE-(PA) 11/13/19CMCORRECTCLOSETX0298ZZ-Floor 1912/2/19 10:00 AMNO0763322
19-530762893RD FL-MECHANICAL RM NEED CLEANING-(PA) 11/13/19CMCORRECTCLOSETX0211ZZ-Floor 0312/2/19 10:00 AMNO0763119

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .