RFP 438478 - Amendment No. 4 21Jun24.pdf

PDF 91 KB Posted

Attached to
HSR BPM Cryo-Cable Assembly
Solicitation number
438478
Issued by

About this file

This document is Amendment No. 4 to Request for Proposal (RFP) No. 438478 for HSR BPM Cryo-Cable Assemblies, which will be procured by the Department of Energy Office of Science for installation in the Hadron Storage Ring of the Electron-Ion Collider. The amendment incorporates Attachment A, which provides clarification on questions related to the cable specifications, including acceptance of non-hermetic assemblies, flexible cable sizes, and bending radii. The RFP requires the Cable Assemblies to carry radio frequency electrical signals from the interior vacuum region of the storage ring through the cryostat insulating vacuum. The agency is open to some variations in the cable specifications to help decrease costs, as long as the performance requirements are met.

View the file

Other files

File Type Posted
QandA_1.17.25.pdf PDF
RFP 438478 - Amendment No. 8 09DEC24.pdf PDF
Enclosure 3 - Proposal Pricing Sheet 03DEC24.pdf PDF
Attachment C - Technical Specification for the EIC HSR BPM Cryo-Cable Assembly Rev 02.pdf PDF
Enclosure 1 - Draft Contract 03DEC24.pdf PDF
STEP Files - Amendment 07.zip ZIP file
1- RFP 438478 - Amendment No. 7 03DEC24.pdf PDF
Attachment B - SOW for the EIC HSR BPM Cryo-Cable Assembly Rev 04.pdf PDF
Attachment D - DWG 2551m0002 Rev E.pdf PDF
RFP 438478 - Amendment No. 6 28Jun24.pdf PDF
RFP 438478 - Amendment No. 5 25Jun24.pdf PDF
RFP 438478 - Amendment No. 3 18Jun24.docx DOCX document
Drawing 2551m0002 Rev D.pdf PDF
STEP Files.zip ZIP file
Enclosure 3 - Proposal Pricing Page 5-28-2024.pdf PDF
RFP 438478 - Amendment No. 2.pdf PDF
RFP 438478 - Amendment No. 1.pdf PDF
1-Request for Proposal 438478 - EIC HSR BPM Cryo-Cable Assembly.pdf PDF
Attachment B - Statement of Work for EIC HSR BPM Cryo-Cable Assembly Rev 02.pdf PDF
Enclosure 1 - BSA Draft Contract.pdf PDF
Enclosure 2 - Annual Representations - Certifications (AMS-FORM-050).pdf PDF
Attachment A -BSA General Terms and Conditions for Non-Commercial Items_Rev22_Sep_2022.pdf PDF
Attachment D - EIC Drawing No. 2551M0002, Rev C..pdf PDF
Enclosure 3 - Proposal Pricing Page.pdf PDF
Attachment E - Supplier Quality Assurance Requirements - QA 101 Form.pdf PDF
Attachment F - Patent Certification AMS Form 032 Rev 1 dated 71917.pdf PDF
Attachment C -Technical Specification Doc No. EIC-ISG-SPC-012 Rev 01.pdf PDF
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Property and Procurement Management Division

Building 1005S P.O. Box 5000

Upton, NY 11973-5000

Date: 06/21/2024

AMENDMENT NO. 4

to

Request for Proposal (RFP) No. 438478

For

HSR BPM Cryo-Cable Assembly

GENERAL: This Amendment No. 4 is to amend Request for Proposal RFP No. 438478 as follows.

1. Incorporate Attachment A – Clarification Questions and Answers dated June 21, 2024, into RFP No. 438478 by reference.

All other terms, conditions, and provisions of this RFP shall remain unchanged.

Material, work, and workmanship, except where specified otherwise in this Amendment shall conform to all requirements of Contract Documents and become a part thereof.

Please confirm receipt of this Amendment No. 4 via email to the following.

Bill Koncelik wkoncelik@bnl.gov

(631) 344-5281 mailto:wkoncelik@bnl.gov

Attachment A

Clarification Questions and Answers

Dated June 21, 2024

1. At your operating frequency of 3 GHz, our cables are very minimally affected by moisture. Will BNL accept non-hermetic assemblies? This would also help decrease costs.

Yes, as long as the cables can pass the leak rate test indicated in the Spec section 3.1.3.3.

2. Is there flexibility on the cable sizes? Our standard with stainless steel jacket is 0.102” and 0.157”. This would make laser welding, if necessary, easier and thus would further decrease cost.

Yes, a tolerance for the cable diameter (0.090” and 0.141”) in the spec is not indicated. The proposed cable diameter variations are small and would be acceptable.

3. Is BNL willing to accept an increased bending radii on the drawings? This would improve cable electrical performance.

No, BNL requires the bending radii indicated in the drawing with an indicated tolerance of +/- 0.125”. If a vendor would like to propose alternative bend radii, we may consider it.