36E77619R0011-006.pdf

PDF 7 MB Posted

Attached to
Construct New Radiation Oncology Suite Milwaukee VAMC (Minor)
Solicitation number
36E77619R0011
Issued by

About this file

36E77619R0011 ATTACHMENT 6 - Radiation Oncology Drawings Final 96-119.pdf

View the file

Other files

File Type Posted
36E77619R0011-0007001.pdf PDF
36E77619R0011-0007000.docx DOCX document
36E77619R0011-0006003.pdf PDF
36E77619R0011-0006000.docx DOCX document
36E77619R0011-0006001.docx DOCX document
36E77619R0011-0006002.pdf PDF
36E77619R0011-0005005.pdf PDF
36E77619R0011-0005006.pdf PDF
36E77619R0011-0005003.pdf PDF
36E77619R0011-0005002.pdf PDF
36E77619R0011-0005004.pdf PDF
36E77619R0011-0005000.docx DOCX document
36E77619R0011-0005001.docx DOCX document
36E77619R0011-0004000.docx DOCX document
36E77619R0011-0004002.pdf PDF
36E77619R0011-0004003.pdf PDF
36E77619R0011-0004001.pdf PDF
36E77619R0011-0003000.docx DOCX document
36E77619R0011-0002005.pdf PDF
36E77619R0011-0002002.pdf PDF
36E77619R0011-0002007.pdf PDF
36E77619R0011-0002010.docx DOCX document
36E77619R0011-0002000.docx DOCX document
36E77619R0011-0002001.pdf PDF
36E77619R0011-0002009.pdf PDF
36E77619R0011-0002008.pdf PDF
36E77619R0011-0002003.docx DOCX document
36E77619R0011-0002006.pdf PDF
36E77619R0011-0002004.pdf PDF
36E77619R0011-0001000.docx DOCX document
36E77619R0011-0001001.pdf PDF
36E77619R0011-000.docx DOCX document
36E77619R0011-005.pdf PDF
36E77619R0011-007.pdf PDF
36E77619R0011-012.pdf PDF
36E77619R0011-003.pdf PDF
36E77619R0011-008.pdf PDF
36E77619R0011-002.pdf PDF
36E77619R0011-001.pdf PDF
36E77619R0011-009.docx DOCX document
36E77619R0011-010.docx DOCX document
36E77619R0011-011.pdf PDF
36E77619R0011-004.pdf PDF
36E77619R0011_1.docx DOCX document
Show all 44

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

e28

C DB

HACCU-B0005

HACCH-B0012

HEF-1

HACCU-1

HRRF-2

WP

NL-54

WP

NL-52

WP

NL-52

WP

NL-54

WP

NL-52

X30

X28

X27

X26

X25

X24

X23

X22

X21

E

FG

A

HSAF-1

WP

NL-52

HACCU-B0004

WP

NL-52

HACCH-B0013

WP

NL-54

HEX-ACCH-L2

WP

NL-54

HEX-ACCH-L1

WP

NL-54

HRRF-1

HSAF-2

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

GUIDON DESIGN INC.

905 N. CAPITOL AVE. SUITE 100 | INDIANAPOLIS, IN. 46204

317.800.6388 | WWW.GUIDONDESIGN.COM

SUSTAINABLE ARCHITECTURE + ENGINEERING

PROJECT LEAD

Architect, Structural Engineer, Civil Engineer

FULLY-SPRINKLERED

PHASING IS DEFINED IN PROJECT SPECIFICATIONS AND PHASING PLANS. CONTRACTOR

TO COORDINATE THE FULL SCOPE OF WORK TO BE PHASED SO AS TO NOT IMPACT THE

OPERATION OF SURROUNDING SPACES OR PREVIOUS PHASES. SPECIFIC COORDINATION

SHOULD BE GIVEN FOR DEMOLITION, UTILITY ROUTING AND SHUTDOWNS.

C U s e rs

\p e rm o \D o c u m e n ts

\7

.0

E

M

P e re z ri n g d u .c o m

.r v t

/2 /2

:2

:0

P

M

ES121P

ROOF PLAN - POWER CONSTRUCT NEW RADIATION

ONCOLOGY SUITE

MILWAUKEE VAMC

695-404

04 OCTOBER 2018 MGM MTP

FINAL CONSTRUCTION

DOCUMENTS BLDG 111

17400 West Capitol Drive, Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778.2360 / r-d@ringdu.com

R&D Project No.:

THIS BAR IS 1" LONG.

IF IT MEASURES ANYTHING OTHER THAN 1"

ADJUST SCALE ACCORDINGLY.

217164.00

1/8" = 1'-0"ES121P

1 ROOF PLAN - ELECTRICAL

1" = 100'-0"

KEY PLAN ROOF

N

N

1.

2.

3.

SHEET NOTES -

EC SHALL REFER TO ARCHITECTURAL

FLOOR PLANS, REFLECTED CEILING PLANS

AND ELEVATIONS FOR EXACT LOCATIONS

AND MOUNTING HEIGHTS.

NORMAL BRANCH POWER CIRCUIT 'NL' IS

208/120V AND SHALL BE FED FORM PANEL

UL-B00-1, UNLESS OTHERWISE NOTED.

REFER TO THE MECHANICAL EQUIPMENT

SCHEDULE ON ES601 FOR PANELS AND

BREAKERS FOR MECHANICAL EQUIPMENT

CIRCUITS.

Revisions: Date:

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OSOS

OS

OS

OS

OS

OS

OS

OS

OS OS

OS

OS

OS

OS

OS

OS

OS

DL

OS

OS OS OS

OSOS

OS

C DB

EXAM

B0205

EXAM

B0206

EXAM

B0209

TOILET

B0212

NURSE PRACTITIONER

B0213

LEAD PHYSICIAN

B0214

TOILET

B0217

CLEAN

B0215

HAC

B0218

CONFERENCE ROOM

B0220

ADMIN

B0216

CANCER CARE

B0228

RESEARCH

B0229

BLOCK MOLD FILM

PROCESS STORAGE

B0230

EXAM

B0211

NURSE

WORKSTATIONS

B0208

RESIDENT

WORKSTATIONS

B0227

RECEPTION

B0201

WAITING

B0200

STAFF LOUNGE

B0221

PHYSICIST

WORKROOM

B0222

LEAD PHYSICIST

B0223

CONTROL ROOM

B0014

CONTROL ROOM

B0011

VITALS

B0203

LOCKERS

B0219

ADMIN

B0224

EXAM

B0210

PHYSICIAN

WORKSTATIONS

B0226

PROCEDURE HOLDING

BAY

B0207

DRESSING / TOILET

B0007

CORRIDOR

C0A15

CORRIDOR

C0A14

CORRIDOR

C0A13

CORRIDOR

C0A12

CORRIDOR

C0A10

MECH / ELEC

B0225

SCHEDULERS

B0202

CORRIDOR

C0A17

LOGISTICS - CLEAN

B0234

DRESSING ROOM

B0010

CT SCANNER

B0004

PHYSICS STORAGE

B0233

LOGISTICS - DIRTY

B0235

HAC

B0230A

LOCKER ROOM

B0240

BREAK ROOM

B0234

HAC

B0232

DOSIMETRY

B0001

DRESSING / TOILET

B0008

CONTROL ROOM

B0002

CT ENTRY ROOM

B0003

SOILED

B0232

WAITING ROOM

B0009

ES302

ES301

ES303

ES201L

ES202L

ES201L

ES202L

ETR

ETR

LINAC 1

B0013

LINAC 2

B0012

CT EQUIPMENT

B0005

CN

R-7

(LH-22)

CN

R-7

CN

R-7

CN

R-7

(LH-22)

AC

NH-10a

CD

NH-10a

AC

CH-9b

CD

NH-10a

AC

CH-9b

CQ

CH-9b

CQ

CH-9b

CQ

NH-10a

CQ

NH-10a

CQ

NH-10a

CQ

CH-9c

CQ

CH-9c

CQ

CH-9b

CQ

NH-10a

CQ

CH-9c

CQ

CH-9c

CQ

NH-10a

CQ

CH-9b

CQ

CH-9a

CQ

CH-9a

CQ

NH-10b

CQ

NH-10b

CQ

CH-9c

CQ

CH-9c

AA

CH-9

CC

NH-12

CC

NH-12

AN

CH-9a

AN

NH-10b

AA

CH-9b

AA

NH-10a

CN

NH-12a

CN

NH-12a

CN

CH-11b

CN

CH-11b

CN

CH-11b

CN

CH-11b

CN

CH-11b

AN

CH-11b

AN

CH-11b

AN

NH-12a

AN

NH-12a

AN

CH-11b

AN

NH-12a

CE

NH-12a

CE

CH-11b

CE

NH-12a

CE

CH-11b

CE

NH-12a

CE

NH-12a

CE

CH-11b

CE

NH-12a

CE

CH-11b

CE

NH-12a

CE

CH-11b

CE

NH-12a

CE

NH-12a

CE

CH-11b

CF

NH-12a

CF

CH-11b

CF

NH-12a

CF

CH-11b

ETR

ETR

ETR

ETR

ETR

ETR

CN

R-3

CN

R-3

CN

R-3

(LH-22)

CN

R-3

Mo

Mo Mo

Mo

Mo

Mo

FC

CH-9

FC

CH-9

FC

NH-10

CQ

NH-10a

CQ

CH-9a

CQ

NH-10b

CQ

CH-9a

CQ

NH-10b

CN

NH-10a

CN

CH-9b

CN

NH-10a

CN

R-7

CC

CH-9

CN

CH-9f

CN

CH-9f

CN

CH-9d

CN

CH-9d

CN

CH-9d

CN

CH-9d

CN

CH-9d

DA

NH-10c

DA

NH-10c

CN

CH-11b

CN

CH-11b

CN

NH-12a

CN

NH-12a

X28

X27

X26

X25

X24

X23

X22

X21

X20

X19

XBXCXDXEXFXG E

FG

A

CN

R-7

CN

R-7

CN

R-7

(LH-22)

CN

R-6

CN

R-6

(LH-22)

CN

R-6

CN

R-6

CN

R-6

(LH-22)

CN

R-6

CN

R-6

(LH-22)

CN

R-6

CN

R-5

(LH-22)

CN

R-5

CN

R-7

(LH-22)

CN

R-7

CD

NH-10a

AC

CH-9b

CD

NH-10a

AC

CH-9b

CD

NH-10a

AC

CH-9b

CD

NH-10a

AC

CH-9b

Mo

WA

CH-9

DA

CH-9

WA

CH-9

DA

CH-9

AC

CH-9b

AC

NH-10a

AN

CH-9a

AN

NH-10b

AN

NH-10a

AN

CH-9b

AN

NH-10a

AN

CH-9b

CQ

NH-10a

CQ

CH-9b

CN

R-3

CN

R-3

(LH-22)CN

R-5

(LH-22)

CN

R-5

CN

R-5

(LH-22)

CN

R-5

CN

R-5

CN

R-5

(LH-22)

CN

R-3

(LH-22)

CN

R-4

CN

R-4

CN

R-4

(LH-22)

CN

R-3

CN

LH-22U

CN

R-2

CN

R-2

(LH-22)

CN

R-2

CN

R-2

XA

XA

XA

XB

AN

CH-11

WA

CH-11

WA

CH-11

DA

CH-11

DA

CH-11

DA

CH-11

DA

CH-11

XA

XA

XA XA

XA

XA

XA

XAXAXA

XA

XA

XA

XA

XA

XA

CT STORAGE

B0006

CN

R-5 a b b a b a b a b a a b ba a b a b ab c d ab ab b a c c b a a b b c b a a b a b b a b a

UC

NL-39

XG

LC

R-8

LC

R-8

LV

LV

LV

LV

LV

LV

LV

LV LV

LV

b a

CN

R-3

CN

NH-12a

CN

NH-12a

CN

NH-12a

CQ

NH-10b

0.04

0.05

0.060.07

0.08

0.09

0.10 0.11

0.12

0.13

CQ

CH-9b

CQ

CH-9b

CQ

CH-9b

CQ

CH-9b

XA

XA

baabbaab a ba b

UC

NL-15

UC

NL-15

UC

NL-15

UC

NL-13

b a f

(LH-22)

(LH-22)

(LH-22)

(LH-22)

(LH-22)

DD

NH-10a

DD

NH-10a

DD

NH-10a

DD

NH-10aDD

NH-10a

DD

NH-10a

DD

NH-10a

DD

NH-10a

DD

NH-10a

DD

NH-10a

DD

NH-10a

LV0.14

LD

R-12

UC

NL-13

CORRIDOR

C0A14

UC

NL-19

CN

R-5

LD

R-11

LD

R-11

LD

R-11

LD

R-11

DB

R-3

DB

R-3

DB

R-4

DA

NH-12

DA

NH-12

DA

NH-12

DA

NH-12

LD

R-12

LD

R-12

LD

R-12

DD

NH-10a

DD

NH-10a

DD

NH-10a

DA

NH-10a

DA

NH-10a

DA

NH-10a

DA

NH-10a

DA

NH-10a

DA

NH-10a DA

NH-10a

DB

CH-9b

DB

CH-9b DB

CH-9b

DB

CH-9b

DB

CH-9b

DB

CH-9b

DB

CH-9b

DB

CH-9b

DB

CH-9b

DB

CH-9b

DB

CH-9b

DB

CH-9b

(LH-22)

CONSULT / EXAM

B0204

XA

CN

R-6

Mo

CN

R-4

CD

CH-9b

CD

NH-10a

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

GUIDON DESIGN INC.

905 N. CAPITOL AVE. SUITE 100 | INDIANAPOLIS, IN. 46204

317.800.6388 | WWW.GUIDONDESIGN.COM

SUSTAINABLE ARCHITECTURE + ENGINEERING

PROJECT LEAD

Architect, Structural Engineer, Civil Engineer

FULLY-SPRINKLERED

PHASING IS DEFINED IN PROJECT SPECIFICATIONS AND PHASING PLANS. CONTRACTOR

TO COORDINATE THE FULL SCOPE OF WORK TO BE PHASED SO AS TO NOT IMPACT THE

OPERATION OF SURROUNDING SPACES OR PREVIOUS PHASES. SPECIFIC COORDINATION

SHOULD BE GIVEN FOR DEMOLITION, UTILITY ROUTING AND SHUTDOWNS.

C

R e v it L o c a lF ile s \7

.0

E k ro c a

.r v t

/2 /2

:4

:3

A M

ES201L

PARTIAL BASEMENT FLOOR PLAN

- LIGHTING

CONSTRUCT NEW RADIATION

ONCOLOGY SUITE

MILWAUKEE VAMC

695-404

04 OCTOBER 2018 MGM MTP

FINAL CONSTRUCTION

DOCUMENTS BLDG 111

1" = 100'-0"

KEY PLAN SOUTH

N

1.

2.

3.

4.

5.

6.

7.

8.

9.

SHEET NOTES -

KEYED NOTES -

REFERENCE ARCHITECTURAL PLANS,

ELEVATIONS AND DETAILS FOR EXACT

LOCATIONS OF ALL DEVICES SHOWN.

CIRCUIT NUMBERS INDICATED DO NOT

REFLECT ACTUAL POSITION OF THE CIRCUIT

BREAKER WITHIN THE PANEL. CIRCUIT

NUMBERS SHOWN REPRESENT INTENT OF

DEVICES CONNECTED TO A COMMON

CIRCUIT.

ALL 208/120 VOLT, NORMAL BRANCH

CIRCUITS "NL" SHALL BE SERVED FROM

PANEL UL-B00-1, UNLESS OTHERWISE NOTED.

ALL 480/277 VOLT, NORMAL BRANCH

CIRCUITS "NH" SHALL BE SERVED FROM

PANEL UH-B00-1, UNLESS OTHERWISE NOTED.

ALL 480/277 VOLT, CRITICAL BRANCH

CIRCUITS "CH" SHALL BE SERVED FROM

PANEL ELH-CR-B02-1, UNLESS OTHERWISE

NOTED.

ALL 480/277 VOLT, LIFE SAFETY BRANCH

CIRCUITS "LH" SHALL BE SERVED FROM

PANEL ELH-LS-B04-1, UNLESS OTHERWISE

NOTED.

ALL EXIT SIGNS SHALL BE WIRED TO CIRCUIT

ELH-LS-B04-1-26 UNLESS OTHERWISE NOTED.

"R" AS IN "R-*" INDICATES A RELAY CONTROL

CIRCUIT FED FROM LIGHTING CONTROL

PANEL LCP/B00-1 UNLESS OTHERWISE NOTED.

REFER TO LIGHTING CONTROL PANEL

SCHEDULE FOR CIRCUIT AND CONTROL

INFORMATION.

REFER TO ARCHITECTURAL PHASING PLANS

FOR EXACT EXTENT OF CONSTRUCTION.

1.

N

1/8" = 1'-0"ES201L

1 PARTIAL BASEMENT PLAN - LIGHTING

17400 West Capitol Drive, Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778.2360 / r-d@ringdu.com

R&D Project No.:

THIS BAR IS 1" LONG.

IF IT MEASURES ANYTHING OTHER THAN 1"

ADJUST SCALE ACCORDINGLY.

217164.00

MOUNT LINEAR FIXTURE 3'-0" ABOVE

BOTTOM EDGE OF SKYLIGHT.

DL

e28

C DB

PET-MRI VESTIBULE

B0015

CORRIDOR

C0A17

ES201L

ES202L

ES201L

ES202L

CN

R-1

(LH-22)

CN

R-1

CN

R-1

CN

R-1

CN

R-1

(LH-22)

CN

R-1

CN

R-1

CN

R-1

CN

R-1

(LH-22)

CN

R-1

FC

NH-12a

FC

CH-11b

E31

X30

X28

E

FGA

XA

XA

XA

XAXA

FC

NH-12a

FC

CH-11b

XA

XA

XA

3a

3a

OD

R-10

OD

R-10

OE

R-9

OE

R-9

OA

R-9

OA

R-9

OA

R-9

3b

3b

OD

R-10

OD

R-10

OD

R-10

OD

R-10

LV

LV

CN

R-2

(LH-22)

CN

R-2

CN

R-2

CN

R-2

(LH-22)

CN

R-2

(LH-22)

(LH-22) (LH-22)

0.01

LV

0.02

0.03

(LH-22)

2 2

MECHANICAL ROOM

B0016

CORRIDOR

C0A19

OD

R-10

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

GUIDON DESIGN INC.

905 N. CAPITOL AVE. SUITE 100 | INDIANAPOLIS, IN. 46204

317.800.6388 | WWW.GUIDONDESIGN.COM

SUSTAINABLE ARCHITECTURE + ENGINEERING

PROJECT LEAD

Architect, Structural Engineer, Civil Engineer

FULLY-SPRINKLERED

PHASING IS DEFINED IN PROJECT SPECIFICATIONS AND PHASING PLANS. CONTRACTOR

TO COORDINATE THE FULL SCOPE OF WORK TO BE PHASED SO AS TO NOT IMPACT THE

OPERATION OF SURROUNDING SPACES OR PREVIOUS PHASES. SPECIFIC COORDINATION

SHOULD BE GIVEN FOR DEMOLITION, UTILITY ROUTING AND SHUTDOWNS.

C U s e rs

\p e rm o \D o c u m e n ts

\7

.0

E

M

P e re z ri n g d u .c o m

.r v t

/2 /2

:2

:2

P

M

ES202L

PARTIAL BASEMENT FLOOR PLAN

- LIGHTING

CONSTRUCT NEW RADIATION

ONCOLOGY SUITE

MILWAUKEE VAMC

695-404

04 OCTOBER 2018 MGM MTP

FINAL CONSTRUCTION

DOCUMENTS BLDG 111

1/4" = 1'-0"ES202L

1 PARTIAL BASEMENT PLAN - LIGHTING NORTH

SHEET NOTES -

KEYED NOTES -

1.

2.

MOUNT FIXTURE TYPE OD, AT 108'-0"

ELEVATION TO BOTTOM OF FIXTURE,

TYPICAL.

MOUNT FIXTURE, TYPE OE, ABOVE DOOR

HEADER, CENTERED BETWEEN DOOR AND

SOFFIT.

17400 West Capitol Drive, Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778.2360 / r-d@ringdu.com

R&D Project No.:

THIS BAR IS 1" LONG.

IF IT MEASURES ANYTHING OTHER THAN 1"

ADJUST SCALE ACCORDINGLY.

217164.00

1.

2.

3.

4.

5.

6.

7.

8.

REFERENCE ARCHITECTURAL PLANS,

ELEVATIONS AND DETAILS FOR EXACT

LOCATIONS OF ALL DEVICES SHOWN.

CIRCUIT NUMBERS INDICATED DO NOT

REFLECT ACTUAL POSITION OF THE

CIRCUIT BREAKER WITHIN THE PANEL.

CIRCUIT NUMBERS SHOWN REPRESENT

INTENT OF DEVICES CONNECTED TO A

COMMON CIRCUIT.

ALL 480/277 VOLT, NORMAL BRANCH

CIRCUITS "NH" SHALL BE SERVED FROM

PANEL UH-B00-1, UNLESS OTHERWISE

NOTED.

ALL 480/277 VOLT, CRITICAL BRANCH

CIRCUITS "CH" SHALL BE SERVED FROM

PANEL ELH-CR-B02-1, UNLESS OTHERWISE

NOTED.

ALL 480/277 VOLT, LIFE SAFETY BRANCH

CIRCUITS "LH" SHALL BE SERVED FROM

PANEL ELH-LS-B04-1, UNLESS OTHERWISE

NOTED.

ALL EXIT SIGNS SHALL BE WIRED TO

CIRCUIT ELH-LS-B04-1-26 UNLESS

OTHERWISE NOTED.

"R" AS IN "R-*" INDICATES A RELAY

CONTROL CIRCUIT FED FROM LIGHTING

CONTROL PANEL LCP/B00-1 UNLESS

OTHERWISE NOTED. REFER TO LIGHTING

CONTROL PANEL SCHEDULE FOR CIRCUIT

AND CONTROL INFORMATION.

REFER TO ARCHITECTURAL PHASING

PLANS FOR EXACT EXTENT OF

CONSTRUCTION.

N

N

1" = 100'-0"

KEY PLAN NORTH

MECH / ELEC

B0225 B00-1

UH

B00-1

EUL-CR

B00-1

LCP

B0225

ECRT-1

B00-1

EUH-Q

B0225

EQRT-1

B00-1

EUL-Q

A

X22

X21

A

CL-15

HTCC-1

HTCC-2

HVAV-XFRMR

B04-1

ELH-LS

EX

X28

B01-1

DL

B01-1

DH

T

EX

EX

EX

X19

XC

B02-1

UL

B02-2

UL

B02-4

UL

B02-3

UL

EQT

B02-1

EUL-Q

EX

EX

EX EX EX

EX

X24

XE

B02-1

ELH-CR

B02-1

EDH-CR

X25

EX

EX

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

GUIDON DESIGN INC.

905 N. CAPITOL AVE. SUITE 100 | INDIANAPOLIS, IN. 46204

317.800.6388 | WWW.GUIDONDESIGN.COM

SUSTAINABLE ARCHITECTURE + ENGINEERING

PROJECT LEAD

Architect, Structural Engineer, Civil Engineer

FULLY-SPRINKLERED

PHASING IS DEFINED IN PROJECT SPECIFICATIONS AND PHASING PLANS. CONTRACTOR

TO COORDINATE THE FULL SCOPE OF WORK TO BE PHASED SO AS TO NOT IMPACT THE

OPERATION OF SURROUNDING SPACES OR PREVIOUS PHASES. SPECIFIC COORDINATION

SHOULD BE GIVEN FOR DEMOLITION, UTILITY ROUTING AND SHUTDOWNS.

C U s e rs

\p e rm o \D o c u m e n ts

\7

.0

E

M

P e re z ri n g d u .c o m

.r v t

/2 /2

:2

:1

P

M

ES300

ENLARGED PLANS CONSTRUCT NEW RADIATION

ONCOLOGY SUITE

MILWAUKEE VAMC

695-404

04 OCTOBER 2018 MGM MTP

FINAL CONSTRUCTION

DOCUMENTS BLDG 111

1/4" = 1'-0"ES300

1 ENLARGED ELECTRICAL ROOM B0225

1/4" = 1'-0"ES300

4 ENLARGED ELECTRICAL ROOM B0448

1/4" = 1'-0"ES300

5 ENLARGED ELECTRICAL ROOM B0114

1/4" = 1'-0"ES300

2 ENLARGED ELECTRICAL ROOM B0214

1/4" = 1'-0"ES300

3 ENLARGED ELECTRICAL ROOM B0219

KEYED NOTES -

1. EXISTING CONDUIT RISERS.

N

17400 West Capitol Drive, Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778.2360 / r-d@ringdu.com

R&D Project No.:

THIS BAR IS 1" LONG.

IF IT MEASURES ANYTHING OTHER THAN 1"

ADJUST SCALE ACCORDINGLY.

217164.00

NNNN

KEYED NOTES -

1. EXISTING JUNCTION BOX FEEDS PARKING

STRUCTURE. BOX SIZE IS APPROXIMATE

AND SHALL BE PROTECTED IN PLACE

DURING CONSTRUCTION.

J

NL-26NL-26NL-26

NL-26 NL-26

L-2

MS4

MS3

L-2 L-2

MS5

MS2

MS1

TC

CL-20

TC

CL-20

L-2

NL-22CL-16 NL-22 CL-16 NL-22

NL-24

CL-18

NL-24

CL-18

ED-2

LINAC 2

B0012

CONTROL ROOM

B0011

G E

N -2

PDCU

C L

-2

CL-20

SDX

SD

MS6

CITB

SV

NL-32

SV

NL-32 SV

NL-32

C

IT

B -2

FB2-2

X28

X27

X26

FG

NL-24

ED-2

LINAC 2

B0012

CONTROL ROOM

B0011

CB

CH-11

CB

CH-11

CB

CH-11

CB

NH-12a

CB

NH-12a

CB

NH-12a

CB

NH-12a

CB

NH-12a

CB

NH-12a

CB

NH-12a

DE

CH-11b

DE

CH-11b

DE

CH-11b

DE

CH-11b

DE

CH-11b

DE

CH-11b

AZ

CH-11c

AZ

CH-11c

DA

CH-11h

DA

CH-11e

DA

CH-11f

CN

NH-12g

CN

NH-12g

33D

D

DD

D h e f g

X28

X27

X26

E FG

XG1

Mo

UC

NL-26

UC

NL-26

DC

NH-12f

DC

NH-12f

DC

NH-12f

DC

NH-12f

DC

NH-12f

DC

NH-12f

DE

CH-11d

DE

CH-11d

DE

CH-11d

DE

CH-11d

D Da b dD

Dfc

FC

NH-12

LINAC 2

B0012

CONTROL ROOM

B0011

4 5

X28

X27

X26

E FG

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

GUIDON DESIGN INC.

905 N. CAPITOL AVE. SUITE 100 | INDIANAPOLIS, IN. 46204

317.800.6388 | WWW.GUIDONDESIGN.COM

SUSTAINABLE ARCHITECTURE + ENGINEERING

PROJECT LEAD

Architect, Structural Engineer, Civil Engineer

FULLY-SPRINKLERED

PHASING IS DEFINED IN PROJECT SPECIFICATIONS AND PHASING PLANS. CONTRACTOR

TO COORDINATE THE FULL SCOPE OF WORK TO BE PHASED SO AS TO NOT IMPACT THE

OPERATION OF SURROUNDING SPACES OR PREVIOUS PHASES. SPECIFIC COORDINATION

SHOULD BE GIVEN FOR DEMOLITION, UTILITY ROUTING AND SHUTDOWNS.

C

R e v it L o c a lF ile s \7

.0

E k ro c a

.r v t

/2 /2

:4

:3

A M

ES301

ENLARGED PLANS CONSTRUCT NEW RADIATION

ONCOLOGY SUITE

MILWAUKEE VAMC

695-404

04 OCTOBER 2018 MGM MTP

FINAL CONSTRUCTION

DOCUMENTS BLDG 111

1/4" = 1'-0"ES301

2 LINAC ROOM B0012 - POWER

N

N

KEYED NOTES -

1.

2.

3.

1.

2.

ELEKTA VERSA HD DELIVERY SYSTEM

REFERENCE DRAWING

THE ELECTRICAL CONTRACTORS SHALL

INCLUDE ALL COSTS ASSOCIATED WITH

THE INSTALLATION OF THE ELECTRICAL

EQUIPMENT AND RACEWAYS INDICATED

ON THE DOCUMENTS DEVELOPED BY

ELEKTA TITLED VERSA HD DELIVERY

SYSTEM REFERENCE DRAWING DATED

JUNE 15, 2016.

FINAL SITE SPECIFIC DRAWINGS WERE NOT

RECEIVED BEFORE SUBMISSION. ALL

CONDUITS, RACEWAYS, AND ANY

EQUIPMENT BEYOND MAIN POWER FEED

"SD" AND "SDX" SHALL BE COORDINATED

PRIOR TO ROUGH-IN.

1.

2.

3.

DRAWING COMMENTS

DRAWING E1

a. ITEM "FB2" IS EQUIPMENT

CONNECTION OUTLET FB2-2 SHOWN

ON THIS DRAWING.

b. ITEM "GEN" IS EQUIPMENT

CONNECTION OUTLET GEN-2 SHOWN

ON THIS DRAWING.

DRAWING E1a

a. CLIENT TERMINAL BOX (CITB)

FURNISHED BY ELEKTA AND

INSTALLED BY EC.

DRAWING E2

a. PROVIDE ALL OF THE CONDUITS

INDICATED IN THE "ELECTRICAL

RACEWAY PLAN." COORDINATE

EXACT LOCATIONS OF ALL

COMPONENTS PRIOR TO ROUGH IN.

b. POWER CONNECTION TO LASERS

CIRCUIT IS EQUIPMENT CONNECTION

L1 SHOWN ON THIS DRAWING.

c. ITEM "ROL" IS LIGHTING FIXTURE XG

SHOWN ON THIS DRAWING.

1/4" = 1'-0"ES301

1 LINAC ROOM B0012 - LIGHTING

17400 West Capitol Drive, Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778.2360 / r-d@ringdu.com

R&D Project No.:

THIS BAR IS 1" LONG.

IF IT MEASURES ANYTHING OTHER THAN 1"

ADJUST SCALE ACCORDINGLY.

217164.00

DETAIL NOTES -

1.

2.

3.

ALL 480/277 VOLT, NORMAL BRANCH

CIRCUITS "NH" SHALL BE SERVED FROM

PANEL UH-B00-1, UNLESS OTHERWISE

NOTED.

ALL 480/277 VOLT, CRITICAL BRANCH

CIRCUITS "CH" SHALL BE SERVED FROM

PANEL ELH-CR-B02-1, UNLESS OTHERWISE

NOTED.

NORMAL POWER BRANCH CIRCUIT "NL" IS

208/120V AND SHALL BE FED FROM PANEL

UL/BO7-1.NORMAL POWER BRANCH

CIRCUIT "NL" IS 208/120V AND SHALL BE

FED FROM PANEL UL/BO7-1.

1/4" = 1'-0"ES301

3 LINAC ROOM B0012 - CONDUIT AND RACEWAY

N

KEYED NOTES -

1.

2.

3.

SWITCH SHALL BE LABELED "LASERS."

BOX MOUNTED CIRCUIT BOARD (CITB) IS

SUPPLIED BY ELEKTA AND INSTALLED BY

EC.

PROVIDE 2#12 IN 3/4" CONDUIT FROM PUSH

BUTTON TO SHUNT TRIP CIRCUIT

BREAKERS. WIRE CIRCUIT IN SERIES WITH

CIRCUIT BREAKERS SD AND SDX.

DETAIL NOTES -

1.

2.

3.

CIRCUIT NUMBERS INDICATED DO NOT

REFLECT THE ACTUAL POSITION OF THE

CIRCUIT BREAKERS IN THE PANEL. RATHER

THE NUMBER INDICATES WHICH DEVICES

ARE CONNECTED TO A COMMON CIRCUIT.

NORMAL POWER BRANCH CIRCUIT "NL" IS

208/120V AND SHALL BE FED FROM PANEL

UL/BO7-1.

CRITICAL POWER BRANCH CIRCUIT "CL" IS

208/120V AND SHALL BE FED FROM PANEL

EULCR/BO7-1

FIXTURE SHALL BE MOUNTED 6" ABOVE

DOOR HEADER, CENTERED OVER DOOR.

WIRE LIGHT FIXTURE THROUGH CITB IN

LINEAR ACCELERATOR ROOM. SEE 1/ES501

FOR WIRING SCHEMATIC.

STACK SWITCHES VERTICALLY. PROVIDE

TWO SWITCH GANGS. BOTTOM GANG

SHALL INCLUDE DIMMERS FOR SWITCH

LEGS "a", "b", AND "d". TOP SWITCH GANG SHALL INCLUDE CONTROLS FOR "c" AND "f" SWITCH LEGS.

DOWNLIGHT, TYPE DC, SHALL BE

CENTERED ON GRAPHIC PANEL. OFFSET

FROM WALL APPROXIMATELY 6 INCHES.

VERIFY FINAL LOCATION FROM

ARCHITECTURAL ELEVATIONS, PRIOR TO

ROUGH-IN, TYPICAL.

KEYED NOTES -

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

PROVIDE 4"W x 9"L GROMMETED CABLE

PASSAGE IN COVER OF FLOOR RACEWAY.

PROVIDE 12"W x 12"L x 12"D FLOOR BOX

WITH REMOVABLE 1/4" THICK STEEL

COVER PLATE, FLUSH MOUNTED FOR

TERMINATION OF UNDERSLAB 4"

CONDUITS.

PROVIDE 10"W x 10"L x 12"D FLOOR BOX, FLUSH MOUNTED WITH FINISH FLOOR. NO

COVER PLATE.

PROVIDE 12"W x 24"L x 12"D FLOOR BOX

WITH REMOVABLE 1/4" THICK STEEL

COVER PLATE, FLUSH MOUNTED FOR

TERMINATION OF UNDERSLAB 4"

CONDUITS.

12" W x MIN. 8"D FLOOR TRENCH

RACEWAY, FLUSH MOUNTED WITH 1/4"

THICK STEEL COVER PLATE.

(3) 4" CONDUITS FROM FB3 TO WJB1. DO

NOT RUN UNDER TABLE PIT. CONDUITS TO

BE WATER TIGHT.

(1) 4" CONDUITS FROM FB3 TO TO FB4.

CONDUIT TO BE WATER TIGHT.

12"W x 3 1/2"D WALL RACEWAY, SURFACE

MOUNTED, WITH REMOVABLE SCREW-

TYPE COVER PLATE.

12"H x 24"L x6"D WALL JUNCTION BOX

WITH REMOVABLE 1/4" THICK STEEL

COVER PLATE, FLUSH MOUNTED WITH

FINISH WALL FOR TERMINATION OF

UNDERSLAB 4" CONDUITS.

PROVIDE 1" CONDUIT FROM FLOOR BOX TO

TABLE PIT. CONDUIT SHALL NOT EXCEED

5'-4".

DETAIL NOTES -

1.

2.

3.

4.

5.

EC SHALL REFER TO ARCHITECTURAL

FLOOR PLANS, REFLECTED CEILING PLANS

AND ELEVATIONS FOR EXACT LOCATIONS

AND MOUNTING HEIGHTS.

COORDINATE ALL UNDERGROUND

CONDUIT ENTRANCE POINTS TO LINEAR

ACCELERATOR ROOM WITH ARCHITECT

AND STRUCTURAL DRAWINGS PRIOR TO

COMMENCING WORK.

CONDUIT ROUTES SHOWN ARE FOR

DIAGRAMMATIC PURPOSES ONLY.

ELECTRICAL CONTRACTOR SHALL

COORDINATE EXACT ROUTE WITH ALL

OTHER DISCIPLINES.

ROUTE ALL ROOM PENETRATIONS AS

PERPENDICULAR TO THE ISOCENTER AS

POSSIBLE TO AVOID RADIATION SCATTER.

VERIFY ALL ROOM PENETRATIONS WITH

THE PHYSICIST OF RECORD.

CONDUIT SHOWN IS FOR ELEKTA

EQUIPMENT REQUIREMENTS, UNLESS

OTHERWISE NOTED.

KEYED NOTES -

11.

12.

13.

14.

PROVIDE 4" x 4" x 4" CEILING JUNCTION

BOX, MOUNTED ABOVE FINISH CEILING AT

HEXAPOD CAMERA LOCATION. PROVIDE

REMOVABLE COVER FOR CABLE PASSAGE.

PROVIDE 6" x 6" WIRE CABLE TRAY

MOUNTED UNDER COUNTERTOP FOR

CABLE MANAGEMENT.

PROVIDE 6" x 6" WALL CHASE FOR

CONNECTION BETWEEN CPU CLOSET AND

CONTROL ROOM. LOCATE BELOW

COUNTERTOP. MATCH HEIGHT TO WIRE

CABLE TRAY.

PROVIDE (1) 1-1/2"C FROM FLOOR BOX TO

PDCU. REFER TO ONE LINE DIAGRAM FOR

ADDITIONAL INFORMATION.

C DB

CONTROL ROOM

B0014

G E

N -1

PDCU

NL-34 CL-10NL-34CL-10NL-34

NL-36

N L

-3

C L

-1

N L

-3

N L

-3

N L

-3

NL-38 NL-38

C L

-1

CL-14

L-1

N L

-3

CL-12

MS6

MS4

MS3

L-1

L-1

MS5

MS2

MS1

SDX

SD

TC

CL-14

TC

CL-14

L-1

LINAC 1

B0013

S V

N L

-4

SV

NL-44

SV

NL-44

C

IT

B

-1CITB

ED-1

FB2-1

X28

X27

X26

ED-1

C DB

CONTROL ROOM

B0014

CN

NH-12k

CN

NH-12k

DA

CH-11g

DA

CH-11h

DA

CH-11j

CB

CH-11

CB

CH-11

CB

CH-11

CB

NH-12a

CB

NH-12a

CB

NH-12a

CB

NH-12a

CB

NH-12a

CB

NH-12a

CB

NH-12a

DE

CH-11b

DE

CH-11b

DE

CH-11b

DE

CH-11b

DE

CH-11b

DE

CH-11b

AZ

CH-11c

AZ

CH-11c

33 D

DD abd

D D

D j hg

Dk

FP

NH-12

X28

X27

X26

E

XG1

D

Df c

DE

CH-11d

DE

CH-11d

DE

CH-11d

DE

CH-11d

DC

NH-12f

DC

NH-12f

DC

NH-12f

UC

NL-38

UC

NL-38

DC

NH-12f

DC

NH-12f

DC

NH-12f

C DB

CONTROL ROOM

B0014

LINAC 1

B0013

X28

X27

X26

E

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

GUIDON DESIGN INC.

905 N. CAPITOL AVE. SUITE 100 | INDIANAPOLIS, IN. 46204

317.800.6388 | WWW.GUIDONDESIGN.COM

SUSTAINABLE ARCHITECTURE + ENGINEERING

PROJECT LEAD

Architect, Structural Engineer, Civil Engineer

FULLY-SPRINKLERED

PHASING IS DEFINED IN PROJECT SPECIFICATIONS AND PHASING PLANS. CONTRACTOR

TO COORDINATE THE FULL SCOPE OF WORK TO BE PHASED SO AS TO NOT IMPACT THE

OPERATION OF SURROUNDING SPACES OR PREVIOUS PHASES. SPECIFIC COORDINATION

SHOULD BE GIVEN FOR DEMOLITION, UTILITY ROUTING AND SHUTDOWNS.

C

R e v it L o c a lF ile s \7

.0

E k ro c a

.r v t

/2 /2

:4

:3

A M

ES302

ENLARGED PLANS CONSTRUCT NEW RADIATION

ONCOLOGY SUITE

MILWAUKEE VAMC

695-404

04 OCTOBER 2018 MGM MTP

FINAL CONSTRUCTION

DOCUMENTS BLDG 111

1/4" = 1'-0"ES302

2 LINAC ROOM B0013 - POWER

N

DETAIL NOTES -

KEYED NOTES -

1.

2.

N

1/4" = 1'-0"ES302

1 LINAC ROOM B0013 - LIGHTING

17400 West Capitol Drive, Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778.2360 / r-d@ringdu.com

R&D Project No.:

THIS BAR IS 1" LONG.

IF IT MEASURES ANYTHING OTHER THAN 1"

ADJUST SCALE ACCORDINGLY.

217164.00

1.

2.

3.

ALL 480/277 VOLT, NORMAL BRANCH

CIRCUITS "NH" SHALL BE SERVED FROM

PANEL UH-B00-1, UNLESS OTHERWISE

NOTED.

ALL 480/277 VOLT, CRITICAL BRANCH

CIRCUITS "CH" SHALL BE SERVED FROM

PANEL ELH-CR-B02-1, UNLESS OTHERWISE

NOTED.

NORMAL POWER BRANCH CIRCUIT "NL" IS

208/120V AND SHALL BE FED FROM PANEL

UL/BO7-1.

1/4" = 1'-0"ES302

4 LINAC ROOM B0013 - CONDUIT AND RACEWAY

KEYED NOTES -

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

PROVIDE 4"W x 9"L GROMMETED CABLE

PASSAGE IN COVER OF FLOOR RACEWAY.

PROVIDE 12"W x 12"L x 12"D FLOOR BOX

WITH REMOVABLE 1/4" THICK STEEL

COVER PLATE, FLUSH MOUNTED FOR

TERMINATION OF UNDERSLAB 4"

CONDUITS.

PROVIDE 10"W x 10"L x 12"D FLOOR BOX, FLUSH MOUNTED WITH FINISH FLOOR. NO

COVER PLATE.

PROVIDE 12"W x 24"L x 12"D FLOOR BOX

WITH REMOVABLE 1/4" THICK STEEL

COVER PLATE, FLUSH MOUNTED FOR

TERMINATION OF UNDERSLAB 4"

CONDUITS.

12" W x MIN. 8"D FLOOR TRENCH

RACEWAY, FLUSH MOUNTED WITH 1/4"

THICK STEEL COVER PLATE.

(3) 4" CONDUITS FROM FB3 TO WJB1. DO

NOT RUN UNDER TABLE PIT. CONDUITS TO

BE WATER TIGHT.

(1) 4" CONDUITS FROM FB3 TO TO FB4.

CONDUIT TO BE WATER TIGHT.

12"W x 3 1/2"D WALL RACEWAY, SURFACE

MOUNTED, WITH REMOVABLE SCREW-

TYPE COVER PLATE.

12"H x 24"L x6"D WALL JUNCTION BOX

WITH REMOVABLE 1/4" THICK STEEL

COVER PLATE, FLUSH MOUNTED WITH

FINISH WALL FOR TERMINATION OF

UNDERSLAB 4" CONDUITS.

PROVIDE 1" CONDUIT FROM FLOOR BOX TO

TABLE PIT.

DETAIL NOTES -

1.

2.

3.

4.

5.

EC SHALL REFER TO ARCHITECTURAL

FLOOR PLANS, REFLECTED CEILING PLANS

AND ELEVATIONS FOR EXACT LOCATIONS

AND MOUNTING HEIGHTS.

COORDINATE ALL UNDERGROUND

CONDUIT ENTRANCE POINTS TO LINEAR

ACCELERATOR ROOM WITH ARCHITECT

AND STRUCTURAL DRAWINGS PRIOR TO

COMMENCING WORK.

CONDUIT ROUTES SHOWN ARE FOR

DIAGRAMMATIC PURPOSES ONLY.

ELECTRICAL CONTRACTOR SHALL

COORDINATE EXACT ROUTE WITH ALL

OTHER DISCIPLINES.

ROUTE ALL ROOM PENETRATIONS AS

PERPENDICULAR TO THE ISOCENTER AS

POSSIBLE TO AVOID RADIATION SCATTER.

VERIFY ALL ROOM PENETRATIONS WITH

THE PHYSICIST OF RECORD.

CONDUIT SHOWN IS FOR ELEKTA

EQUIPMENT REQUIREMENTS, UNLESS

OTHERWISE NOTED.

N

KEYED NOTES -

1.

2.

3.

SWITCH SHALL BE LABELED "LASERS."

BOX MOUNTED CIRCUIT BOARD (CITB) IS

SUPPLIED BY ELEKTA AND INSTALLED BY

EC. REFER TO DETAIL 1/ES501 FOR WIRING

PROVIDED BY EC.

PROVIDE 2#12 IN 3/4" CONDUIT FROM PUSH

BUTTON TO SHUNT TRIP CIRCUIT

BREAKERS. WIRE CIRCUIT IN SERIES WITH

CIRCUIT BREAKERS SD AND SDX.

DETAIL NOTES -

1.

2.

3.

CIRCUIT NUMBERS INDICATED DO NOT

REFLECT THE ACTUAL POSITION OF THE

CIRCUIT BREAKERS IN THE PANEL. RATHER

THE NUMBER INDICATES WHICH DEVICES

ARE CONNECTED TO A COMMON CIRCUIT.

NORMAL POWER BRANCH CIRCUIT "NL" IS

208/120V AND SHALL BE FED FROM PANEL

UL/BO7-1.

CRITICAL POWER BRANCH CIRCUIT "CL" IS

208/120V AND SHALL BE FED FROM PANEL

EULCR/BO7-1

FIXTURE SHALL BE MOUNTED 6" ABOVE

DOOR HEADER, CENTERED OVER DOOR.

WIRE LIGHT FIXTURE THROUGH CITB IN

LINEAR ACCELERATOR ROOM. SEE 1/ES501

FOR WIRING SCHEMATIC.

STACK SWITCHES VERTICALLY. PROVIDE

TWO SWITCH GANGS. BOTTOM GANG

SHALL INCLUDE DIMMERS FOR SWITCH

LEGS "a", "b", AND "d". TOP SWITCH GANG SHALL INCLUDE CONTROLS FOR "c" AND "f" SWITCH LEGS.

1.

2.

ELEKTA VERSA HD DELIVERY SYSTEM

REFERENCE DRAWING

THE ELECTRICAL CONTRACTORS SHALL

INCLUDE ALL COSTS ASSOCIATED WITH

THE INSTALLATION OF THE ELECTRICAL

EQUIPMENT AND RACEWAYS INDICATED

ON THE DOCUMENTS DEVELOPED BY

ELEKTA TITLED VERSA HD DELIVERY

SYSTEM REFERENCE DRAWING DATED

JUNE 15, 2016.

FINAL SITE SPECIFIC DRAWINGS WERE NOT

RECEIVED BEFORE SUBMISSION. ALL

CONDUITS, RACEWAYS, AND ANY

EQUIPMENT BEYOND MAIN POWER FEED

"SD" AND "SDX" SHALL BE COORDINATED

PRIOR TO ROUGH-IN.

1.

2.

3.

DRAWING COMMENTS

DRAWING E1

a. ITEM "FB2" IS EQUIPMENT

CONNECTION OUTLET FB2-1 SHOWN

ON THIS DRAWING.

b. ITEM "GEN" IS EQUIPMENT

CONNECTION OUTLET GEN-1 SHOWN

ON THIS DRAWING.

DRAWING E1a

a. CLIENT TERMINAL BOX (CITB)

FURNISHED BY ELEKTA AND

INSTALLED BY EC.

DRAWING E2

a. PROVIDE ALL OF THE CONDUITS

INDICATED IN THE "ELECTRICAL

RACEWAY PLAN." COORDINATE

EXACT LOCATIONS OF ALL

COMPONENTS PRIOR TO ROUGH IN.

b. POWER CONNECTION TO LASERS

CIRCUIT IS EQUIPMENT CONNECTION

L1 SHOWN ON THIS DRAWING.

c. ITEM "ROL" IS LIGHTING FIXTURE XG

SHOWN ON THIS DRAWING.

KEYED NOTES -

11.

12.

13.

14.

PROVIDE 4" x 4" x 4" CEILING JUNCTION

BOX, MOUNTED ABOVE FINISH CEILING AT

HEXAPOD CAMERA LOCATION. PROVIDE

REMOVABLE COVER FOR CABLE PASSAGE.

PROVIDE 6" x 6" WIRE CABLE TRAY

MOUNTED UNDER COUNTERTOP FOR

CABLE MANAGEMENT.

PROVIDE 6" x 6" WALL CHASE FOR

CONNECTION BETWEEN CPU CLOSET AND

CONTROL ROOM. LOCATE BELOW

COUNTERTOP. MATCH HEIGHT TO WIRE

CABLE TRAY.

PROVIDE (1) 1-1/2"C FROM FLOOR BOX TO

PDCU. REFER TO ONE LINE DIAGRAM FOR

ADDITIONAL INFORMATION.

J

J

J

J

D

CT SCANNER

B0004

CONTROL ROOM

B0002

CT ENTRY ROOM

B0003

CT STORAGE

B0006

SPD

PDC

DD

GFI

CL-6

UL-B00-1-18

C L

-6

UL-B00-1-18

UL-B00-1-18

UL-B00-1-16 UL-B00-1-16

UL-B00-1-16

C L

-6EPO

EPO

EPO

X26

X25

X24

X23

E FG

HRACU-B0004

UL-B00-1-18

48"

UL-B00-1-20

CT EQUIPMENT

B0005

UL-B00-1-16

UL-B00-1-18

CL-8

CL-8

CL-8

L-3

L-3

L-3

MP

UL-B00-1-16

D

CT SCANNER

B0004

CONTROL ROOM

B0002

CT ENTRY ROOM

B0003

CN

NH-12l CN

NH-12l

CN

NH-12l

AA

CH-11

DA

CH-11m

DA

CH-11n

CB

NH-12a

CB

NH-12a

CB

NH-12a

CB

NH-12a

CB

NH-12a

CB

NH-12a

CB

NH-12a

DE

CH-11b

DE

CH-11b

DE

CH-11b

DE

CH-11b

DE

CH-11b

DE

CH-11b

AZ

CH-11c

AZ

CH-11c

3 D DDl m n

Dp CH-11p

DA

3l

DD cba

X

X25

X24

X23

E FG

Mo Mo

XG

DC

NH-12c

DC

NH-12c

DC

NH-12c

DC

NH-12c

UC

NL-18

UC

NL-18

AA

NH-12

AA

NH-12

AA

NH-12

AA

NH-12

AA

NH-12

Dd

CT STORAGE

B0006

CT EQUIPMENT

B0005

D

X26

X25

X24

X23

E FG

CT SCANNER

B0004

CONTROL ROOM

B0002

CT ENTRY ROOM

B0003

CT STORAGE

B0006

VD1

CT EQUIPMENT

B0005

DRESSING ROOM

B0010

MP

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

GUIDON DESIGN INC.

905 N. CAPITOL AVE. SUITE 100 | INDIANAPOLIS, IN. 46204

317.800.6388 | WWW.GUIDONDESIGN.COM

SUSTAINABLE ARCHITECTURE + ENGINEERING

PROJECT LEAD

Architect, Structural Engineer, Civil Engineer

FULLY-SPRINKLERED

PHASING IS DEFINED IN PROJECT SPECIFICATIONS AND PHASING PLANS. CONTRACTOR

TO COORDINATE THE FULL SCOPE OF WORK TO BE PHASED SO AS TO NOT IMPACT THE

OPERATION OF SURROUNDING SPACES OR PREVIOUS PHASES. SPECIFIC COORDINATION

SHOULD BE GIVEN FOR DEMOLITION, UTILITY ROUTING AND SHUTDOWNS.

C U s e rs

\p e rm o \D o c u m e n ts

\7

.0

E

M

P e re z ri n g d u .c o m

.r v t

/2 /2

:2

:5

P

M

ES303

ENLARGED PLANS CONSTRUCT NEW RADIATION

ONCOLOGY SUITE

MILWAUKEE VAMC

695-404

04 OCTOBER 2018 MGM MTP

FINAL CONSTRUCTION

DOCUMENTS BLDG 111

1/4" = 1'-0"ES303

2 CT SCAN ROOM B0004 - POWER

N

1.

2.

SIEMENS SOMATOM CONFIDENCE

TYPICAL FINAL DRAWING SET

KEYED NOTES -

THE ELECTRICAL CONTRACTORS SHALL

INCLUDE ALL COSTS ASSOCIATED WITH

THE INSTALLATION OF THE ELECTRICAL

EQUIPMENT AND RACEWAYS INDICATED

ON THE DOCUMENTS DEVELOPED BY

SIEMENS' TITLED SOMATOM CONFIDENCE

TYPICAL FINAL DRAWING SET.

FINAL SITE SPECIFIC DRAWINGS WERE NOT

RECEIVED BEFORE SUBMISSION. ALL

CONDUITS, RACEWAYS, AND ANY

EQUIPMENT BEYOND MAIN POWER FEED

"MP" SHALL BE COORDINATED PRIOR TO

ROUGH-IN.

1.

2.

DISCONNECT ENCLOSURE "MP" AS

INDICATED ON SHEET E-101 & E-102 OF

MANUFACTURERS TYPICAL SITE

DRAWINGS.

EPO'S MUST HAVE FAIL SAFE DESIGN AND

MECHANICAL LATCHING MECHANISM.

N

DETAIL NOTES -

1.

DRAWING COMMENTS

DRAWINGS E-101

a. INSTALL ALL OF THE CONDUITS

INDICATED IN THE "ELECTRICAL

RACEWAY PLAN." COORDINATE

EXACT LOCATIONS OF ALL

COMPONENTS PRIOR TO ROUGH IN.

b. ALL 120VOLT CIRCUITS ARE SHOWN

ON THE ELECTRICAL/TECHNOLOGY

DRAWINGS.

c. REFER TO ELECTRICAL ONE LINE

DIAGRAM AND PANEL SCHEDULE FOR

ADDITIONAL INFORMATION ON MAIN

PANEL "MP."

17400 West Capitol Drive, Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778.2360 / r-d@ringdu.com

R&D Project No.:

THIS BAR IS 1" LONG.

IF IT MEASURES ANYTHING OTHER THAN 1"

ADJUST SCALE ACCORDINGLY.

217164.00

1.

2.

3.

ALL 480/277 VOLT, NORMAL BRANCH

CIRCUITS "NH" SHALL BE SERVED FROM

PANEL UH-B00-1, UNLESS OTHERWISE

NOTED.

ALL 480/277 VOLT, CRITICAL BRANCH

CIRCUITS "CH" SHALL BE SERVED FROM

PANEL ELH-CR-B02-1, UNLESS OTHERWISE

NOTED.

NORMAL POWER BRANCH CIRCUIT "NL" IS

208/120V AND SHALL BE FED FROM PANEL

UL-B00-1.

1/4" = 1'-0"ES303

1 CT SCAN ROOM B0004 - LIGHTING

1/4" = 1'-0"ES303

3 CT SCAN ROOM B0004 - CONDUITS AND RACEWAY

KEYED NOTES -

1.

2.

3.

4.

PROVIDE PULL BOX MOUNTED FLUSH WITH

FINISHED WALL PROVIDED WITH 2"Ø

OPENING IN FINISHED COVER. LOCATE THE

SPD WITHIN 3 FEET CABLE RUN FROM

CIRCUIT BREAKER. VERIFY HEIGHT WITH

OWNER PRIOR TO INSTALL.

PROVIDE 10" x 3-1/2" VERTICAL

ELECTRICAL DUCT WITH FINISHED,

REMOVABLE COVERS MOUNTED FLUSH

WITH FINISHED WALL. DUCT SHALL

EXTEND FROM FROM FLOOR LINE TO END

ABOVE FINISHED CEILING. DIVIDE DUCT

INTO TWO SECTIONS WITH METAL

DIVIDERS.

PROVIDE 10" x 3-1/2" HORIZONTAL

ELECTRICAL DUCT SURFACE MOUNTED AT

THE FLOOR LINE. DIVIDE DUCT INTO TWO

SECTIONS WITH METAL DIVIDERS.

PROVIDE 10"X4" OPENING WHERE KEYED

NOTE IS SHOWN.

APPROXIMATE CONDUIT ROUTE BETWEEN

EPO'S. PROVIDE 2#12 & 1#12 GND IN

3/4"CONDUIT BETWEEN EPO'S.

DETAIL NOTES -

1.

2.

3.

4.

EC SHALL REFER TO ARCHITECTURAL

FLOOR PLANS, REFLECTED CEILING PLANS

AND ELEVATIONS FOR EXACT LOCATIONS

AND MOUNTING HEIGHTS.

CONDUIT ROUTES SHOWN ARE FOR

DIAGRAMMATIC PURPOSES ONLY.

ELECTRICAL CONTRACTOR SHALL

COORDINATE EXACT ROUTE WITH ALL

OTHER DISCIPLINES.

CONDUIT SHOWN IS FOR SIEMENS

EQUIPMENT REQUIREMENTS, UNLESS

OTHERWISE NOTED.

EC SHALL LEAVE A MINIMUM OF 10 FEET

OF WIRE TAILS AT ALL OUTLET POINTS

WITH WIRE IDENTIFICATION TAGGED AT

BOTH ENDS FOR FINAL CONNECTION.

DETAIL NOTES -

1.

2.

3.

CIRCUIT NUMBERS INDICATED DO NOT

REFLECT THE ACTUAL POSITION OF THE

CIRCUIT BREAKERS IN THE PANEL. RATHER

THE NUMBER NUMBERS INDICATE WHICH

DEVICES ARE CONNECTED TO A COMMON

CIRCUIT.

NORMAL POWER BRANCH CIRCUIT "NL" IS

208/120V AND SHALL BE FED FROM PANEL

UL-B00-1.

CRITICAL POWER BRANCH CIRCUIT "CL" IS

208/120V AND SHALL BE FED FROM PANEL

EUL-CR-B00-1

N

KEYED NOTES -

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

PROVIDE PULL BOX MOUNTED ABOVE

FINISH CEILING. SIZE BOX AS REQUIRED

FOR CONDUIT TERMINATIONS.

PROVIDE PULL BOX MOUNTED FLUSH WITH

FINISHED WALL. SIZE BOX AS REQUIRED

FOR CONDUIT TERMINATIONS.

PROVIDE 12" x 2-1/2" ELECTRICAL DUCT

MOUNTED FLUSH WITH FINISHED FLOOR.

DUCT SHALL HAVE WATERPROOF

REMOVABLE COVERS WITH FINISHES TO

MATCH FLOORING. DIVIDE DUCT INTO

TWO SECTIONS WITH METAL DIVIDERS.

PROVIDE (2) 12" X 5" RACEWAY OPENINGS

FLUSH WITH THE FINISHED FLOOR.

PROVIDE 12" X 8" RACEWAY OPENINGS

FLUSH WITH THE FINISHED FLOOR.

PROVIDE (1) 3/4" CONDUIT FROM DUCT TO

DOOR SWITCH.

APPROXIMATE CONDUIT ROUTE BETWEEN

"MP" AND PDC. REFER TO ONE LINE

DIAGRAM FOR ADDITIONAL INFORMATION.

PROVIDE 2-1/2" CONDUIT FROM VERDICAL

DUCT VD1 TO VD2.

PROVIDE 3" CONDUIT FROM PULL BOX TO

VERTICAL DUCT.

PROVIDE 1" CONDUIT INBETWEEN LASER

JUNCTION BOXES.

CONDUIT LEGEND

ABOVE ACCESSIBLE CEILING

BENEATH FLOOR SLAB

KEYED NOTES -

1.

2.

FIXTURE SHALL BE MOUNTED 6" ABOVE

DOOR HEADER, CENTERED OVER DOOR.

DOWNLIGHT, TYPE DC, SHALL BE

CENTERED ON GRAPHIC PANEL. OFFSET

FROM WALL APPROXIMATELY 6 INCHES.

VERIFY FINAL LOCATION FROM

ARCHITECTURAL ELEVATIONS, PRIOR TO

ROUGH-IN, TYPICAL.

XX

XX

MANUAL OR AUTOMATIC

PANELBOARD - REFER TO PANEL

OVERLOAD

ENCLOSURE

EQUIPMENT CONNECTION -

ENGINE GENERATOR

TRANSFORMER

XX

XX

SURGE SUPPRESSION

DENOTES

LA = LIGHTNING ARRESTORS

SPD = SURGE PROTECTIVE DEVICE

FEEDER CONTINUATION CONNECTION #

FEEDER CONTINUED ON SHEET INDICATED

DEVICE UPSTREAM OR DOWNSTREAM

(CAP)

(ATS)

CAPACITOR

AUTOMATIC TRANSFER SWITCH

KEY INTERLOCKING - KEY #

KEY NORMALLY REMOVED

SEE EQUIPMENT SCHEDULE

"AF" - DENOTES AMP FRAME

"XXX" - DENOTES AMP RATING

GP - GROUND FAULT PROTECTION - PERSONNEL

UVT - UNDER VOLTAGE TRIP

ST - SHUNT TRIP

MC - MOLDED CASE CIRCUIT BREAKER

SS - SOLID STATE MOLDED CASE CIRCUIT BREAKER

IC - INSULATED CASE CIRCUIT BREAKER

PC - LOW VOLTAGE POWER CIRCUIT BREAKER

GE - GROUND FAULT PROTECTION - EQUIPMENT

ALS - ALARM SWITCH

AXS - AUXILIARY SWITCH

EOP - ELECTRIC OPERATOR

AF - ARC FAULT CIRCUIT INTERRUPTER (RESIDENTIAL ONLY)

CL - CURRENT LIMITING

(XX) DEVICE DESIGNNATION

DENOTES THE FOLLOWING:

DENOTES THE FOLLOWING:

(CB) CIRCUIT BREAKER

(CON) CONTACTOR

(DS) DISCONNECT SWITCH

(VM)

(AM)

VOLTMETER

AMMETER

DENOTES THE FOLLOWING:

(VS) VOLTMETER SWITCH

(AS) AMMETER SWITCH

(M) KWHR METER

(DM) DIGITAL METER

XX

(XX) DEVICE DESIGNATION TYPE -

DENOTES THE FOLLOWING:

SEE SPECIFICATION

-SEE SCHEDULE & DETAILS

"AS" - DENOTES AMP SENSOR

"AT" - DENOTES AMP TRIP

GS - GROUND FAULT SENSING / ALARM

HC - HEATING, COOLING, AIR CONDITIONING, REFRIGERATION - HCAR

HM - HIGH MAGNETIC - HID, MOTORS

MS - MOLDED CASE SWITCH

MP - MOTOR CIRCUIT PROTECTOR

L1 - LONG TIME / INSTANTANEOUS - LI

L2 - LONG TIME / SHORT TIME / INSTANTANEOUS - LSI

L3 - LONG TIME / SHORT TIME / INSTANTANEOUS / GROUND FAULT TRIP - LSIG

L4 - LONG TIME / SHORT TIME / INSTANTANEOUS / GROUND FAULT SENSING - LSIA

SC - SYSTEM COMMUNICATION

SD - SYSTEM DIAGNOSTICS

SM - SYSTEM MONITORING

ZS - ZONE SELECTIVE INTERLOCKING

"XXX" - DENOTES AMP RATING

VW - VIEWING WINDOW

AXS - AUXILIARY SWITCH

DL - DOUBLE LUGS

PL - PILOT LIGHT

DS - UNFUSED DISCONNECT SWITCH

EDS - ELEVATOR DISCONNECT SWITCH

"AS" - DENOTES AMP SWITCH

"AF" - DENOTES AMP FUSE

AR - ARC FLASH REDUCTION

LOW VOLTAGE

LOW VOLTAGE FUSED

LOW VOLTAGE

LOW VOLTAGE

LOW VOLTAGE

FUSE

DISCONNECT SWITCH

DISCONNECT SWITCH

CIRCUIT BREAKER

DRAWOUT

LOW VOLTAGE

DRAWOUT POWER

CIRCUIT BREAKER

CIRCUIT BREAKER

POTENTIAL TRANSFORMER

CURRENT TRANSFORMER

CAPACITOR

GROUND

G

JUNCTION BOX

KEY INTERLOCKING - KEY #

KEY NORMALLY INSERTED

-SEE SCHEDULE & DETAILS

TRANSFER SWITCH

NORMALLY CLOSED

CONTACTOR

NORMALLY OPEN

CONTACTOR

CONTROL SWITCH

FLOAT SWITCH

LIGHT FIXTURE

NO

NC

NO

FR - FULLY RATED (100%)

1.

NEW.

2.

ARE EXISTING TO REMAIN.

3.

BELOW ARE EXISTING TO BE REMOVED.

4.

BELOW ARE TYPICAL EQUIPMENT DIVISIONS.

5.

FUTURE.

6.

BE KEPT TO AN ABSOLUTE MINIMUM.

7.

DIAGRAM SHALL BE PROTECTED FROM AVAILABLE FAULT CURRENT

SHOWN BY EITHER OF THE FOLLOWING METHODS:

- PROVIDE BREAKERS WITH A MINIMUM AIC RATING GREATER THAN

INDICATED

- THE SERIES RATING METHOD IS NOT ACCEPTABLE

1 - NON VENTILATED ENCLOSURE

2 - INTEGRAL STRIP HEATER

3 - WEATHER SHIELD

OPTIONS

TEMPERATURE RISE

SECONDARY VOLTAGE

PRIMARY VOLTAGE

kVA

TRANSFORMER ID

RATING

TYPE

DT - DRY TYPE

LF - LIQUID FILLED

DP - DRY TYPE PAD MOUNT

LP - LIQUID FILLED PAD MOUNT

GP - GENERAL PURPOSE

K-# - K-RATED

EE - ENERGY EFFICIENT

4 - NEMA 3R

5 - STAINLESS STEEL

CR - CAST RESIN

EC - ENCAPSULATED CORE

N - NORMAL BRANCH

LS - LIFE SAFETY BRANCH

CR - CRITICAL CARE BRANCH

BRANCH

EQ - EQUIPMENT BRANCH

EM - EMERGENCY BRANCH

TRANSFER SWITCH ID

ES - ESSENTIAL SYSTEMS

NES - NON ESSENTIAL SYSTEMS

AMPS

VOLTAGE

CLOSING & WITHSTAND AIC RATING

TRANSFER

AUTO - AUTOMATIC

MAN - MANUAL

POLES

TRANSFER SWITCH TYPE

OPTIONS

1 - LOAD SHED RELAY

2 - BLOCK TRANSFER RELAY

3 - SYNCH CHECK RELAY

4 - PEAK READING AMMETER

5 - STANDARD METER

6 - VOLTMETER

7 - COMPRESSION LUGS

8 - ELEVATOR INTERFACE RELAY

BYPASS

NON BYPASS

FIRE PUMP

TRANSITION

OPEN TRANSITION

CLOSED TRANSITION

DELAYED TRANSITION

TYPE

OPTIONS

1 - UNIT STATUS INDICATORS

2 - AUDIBLE ALARM

3 - TRANSIENT COUNTER

4 - REMOTE MONITOR PANEL

5 - SERVICE DISCONNECT SWITCH

6 - SUMMARY ALARM RELAY CONTACTS

7 - HIGH PERFORMANCE INTERCONNECT CABLE

SE - 125 kA - SERVICE ENTRANCE BP - 80 kA - BRANCH PANEL VOLTAGE

SPD ID

BYPASS ISOLATION

TRANSFER SWITCH

MOUNTING TYPE

8 - MASTERMIND MONITORING

(JB) JUNCTION BOX

(MTS) MANUAL TRANSFER SWITCH

(T) TRANSFORMER

(SS) SURGE SUPPRESSION

(UPS) UNINTERRUPTIBLE POWER SUPPLY

(WW) WIREWAY

(FS) FUSIBLE SWITCH

(F) FUSE

(MVF) MEDIUM VOLTAGE FUSE

(MVFS) MEDIUM VOLTAGE FUSIBLE SWITCH

(MVS) MEDIUM VOLTAGE SWITCH

(MVT) MEDIUM VOLTAGE CABLE TERMINATION

(PLC) POWER LINE CONDITIONER

(MVC) MEDIUM VOLTAGE FUSED CUTOUT

(EDP) ELEVATOR DISTRIBUTION PANEL

(EDS) ELEVATOR DISCONNECT SWITCH

MD - MODIFIED DIFFERENTIAL GROUND FAULT

(BW) BUS WAY

BUS

COPPER

ALUMINUM

TYPE

INDOOR

OUTDOOR

CYCLE CLOSING & WITHSTAND RATING

3 CYCLE

30 CYCLE

9 - OVERLAPPING NEUTRAL CONTACTS

10 - DIGITAL METERING

ALL ITEMS INDICATED BY A DARK SOLID LINE AS SHOWN BELOW ARE

ALL ITEMS INDICATED BY A LIGHT DASHED LINE AS SHOWN BELOW

ALL ITEMS INDICATED BY A DARK DASH-DOT-DASH LINE AS SHOWN

ALL ITEMS INDICATED BY A LIGHT DASH-DOT-DASH LINE AS SHOWN

ALL ITEMS INDICATED BY A LIGHT SOLID LINE AS SHOWN BELOW ARE

ALL DOWNTIME SHALL BE SCHEDULED WITH THE OWNER AND SHALL

THE PANELS AND SWITCHBOARDS INDICATED ON THE ONE LINE

FS - FUSED DISCONNECT SWITCHLABELING SCHEME FOR DESIGNATIONS

XX

XXX

XXX

XX

XXXXX

XXXAF

XXXAS

XXXAT

3P

FS XXX

XXXAS

XXXAF

3P K#

K#

X

X

EXX

XXX/XX

X

XX

X

XXX kVA

/ X / X

P: XXX

S: XXX

XXX XXX

X / X / X / X / X

XXX

XXX

XXX

XXX XXX

XXXXXX

XXX

XXX

XXX

X / X / X / X

XXX

XXXXXX

XXXXXX

DS XXX

XXXAS

XXXAF

3P

XXXXXX

XXXXXX

MIN AIC RATING =

XXX VOLTS 3Ø 4W

RMS SYM @ XXX VOLTS

XXXk AMPS

XXX AMPS @

XXX XXXBUS: TYPE:

XXX

CIRCUIT BREAKER INFORMATION

CIRCUIT BREAKER ACCESSORIES

CIRCUIT BREAKER TYPE

ONE-LINE SYMBOLS

CIRCUIT BREAKER OPTIONS

LOW VOLTAGE DISCONNECT SWITCH INFORMATION

DISCONNECT SWITCH ACCESSORIES

DISCONNECT SWITCH TYPE

PANEL LABELING SCHEME

GENERAL NOTES -

T

TRANSFORMER INFORMATION

ATS

TRANSFER SWITCH INFORMATION

SPD

SURGE PROTECTIVE DEVICE

BW/

BUS WAY

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

GUIDON DESIGN INC.

905 N. CAPITOL AVE. SUITE 100 | INDIANAPOLIS, IN. 46204

317.800.6388 | WWW.GUIDONDESIGN.COM

SUSTAINABLE ARCHITECTURE + ENGINEERING

PROJECT LEAD

Architect, Structural Engineer, Civil Engineer

FULLY-SPRINKLERED

PHASING IS DEFINED IN PROJECT SPECIFICATIONS AND PHASING PLANS. CONTRACTOR

TO COORDINATE THE FULL SCOPE OF WORK TO BE PHASED SO AS TO NOT IMPACT THE

OPERATION OF SURROUNDING SPACES OR PREVIOUS PHASES. SPECIFIC COORDINATION

SHOULD BE GIVEN FOR DEMOLITION, UTILITY ROUTING AND SHUTDOWNS.

C U s e rs

\p e rm o \D o c u m e n ts

\7

.0

E

M

P e re z ri n g d u .c o m

.r v t

/2 /2

:2

:4

P

M

ES400

ONE LINE SYMBOLS CONSTRUCT NEW RADIATION

ONCOLOGY SUITE

MILWAUKEE VAMC

695-404

04 OCTOBER 2018 MGM MTP

FINAL CONSTRUCTION

DOCUMENTS BLDG 111

17400 West Capitol Drive, Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778.2360 / r-d@ringdu.com

R&D Project No.:

THIS BAR IS 1" LONG.

IF IT MEASURES ANYTHING OTHER THAN 1"

ADJUST SCALE ACCORDINGLY.

217164.00Revisions: Date:

RMS SYM @ 240 VOLTS

208/120 VOLTS 3Ø 4W

POWER PANEL CONSTRUCTION

INDIVIDUAL FIXED

65k AMPS

GROUP MOUNTED

RMS SYM @ 480 VOLTS

480/277 VOLTS 3Ø 4W

POWER PANEL CONSTRUCTION

____k AMPS

GROUP MOUNTED

RMS SYM @ 480 VOLTS

480 VOLTS 3Ø 3W

POWER PANEL CONSTRUCTION

GROUP MOUNTED

65k AMPS

GROUP MOUNTED

SS

P: 480V DELTA

S: 208Y/120V

DT 75 kVA

MC

1-1/4"C.

#3 &3

#8 GRD1

COPPER

MC

2"C.

#1/0 &4

#6 GRD1

COPPER

RMS SYM @ 480 VOLTS

480/277 VOLTS 3Ø 4W

POWER PANEL CONSTRUCTION

GROUP MOUNTED

65k AMPS

GROUP MOUNTED

MC

MC

RMS SYM @ 480 VOLTS

480/277 VOLTS 3Ø 4W

POWER PANEL CONSTRUCTION

INDIVIDUAL FIXED

65k AMPS

GROUP MOUNTED

P: 480V DELTA

S: 208Y/120V

EE 150°C

DT 45 kVA

FLOOR

DSDS

2"C.

SS

L2

MC

MC

MC

2-1/2"C.

#1/0 &4

#1/0 GRD1

COPPER

SS

L2

2-1/2"C.

#1 &4

#1 GRD1

COPPER

1"C.

#10 &4

#10 GRD1

COPPER

ST ST

2"C.

#3 &4

#3 GRD1

COPPER

1-1/2"C.

#6 &4

#6 GRD1

COPPER

1-1/2"C.

#6 &4

#6 GRD1

COPPER

1-1/2"C.

#4 &4

#4 GRD1

COPPER

MC

MC

MC

3"C.

#1/0 &4

#1/0 GRD1

COPPER

MC ST ST

3"C.

#1/0 &4

#1/0 GRD1

COPPER

1-1/2"C.

#6 &4

#6 GRD1

COPPER

1-1/2"C.

#6 &4

#6 GRD1

COPPER

1-1/2"C.

#4 &4

#4 GRD1

COPPER

P: 480V DELTA

S: 208Y/120V

EE 150°C

DT 45 kVA

2"C.

#2/0 &4

#6 GRD1

COPPER

DS

2-1/2"C.

#3/0 &4

#6 GRD1

COPPER

2-1/2"C.

#3/0 &4

#6 GRD1

COPPER

SS

L2

2-1/2"C.

#4/0 &3

#4 GRD1

COPPER

1"C.

#6 &3

#10 GRD1

COPPER

P: 480V DELTA

S: 208Y/120V

EE 150°C

DT 30 kVA

1-1/2"C.

#2 &4

#6 GRD1

COPPER

RMS SYM @ 480 VOLTS

480/277 VOLTS 3Ø 4W

POWER PANEL CONSTRUCTION

65k AMPS

GROUP MOUNTED

MC

2-1/2"C.

#4/0 &4

#4 GRD1

COPPER

SS

L2

P: 480V DELTA

S: 208Y/120V

DT 300 kVA

FLOOR

SS

DS DS

2-1/2"C.

#1 &4

#1 GRD1

COPPER

ECRT

B002

DS

PETMRI

DS

PDCU

SD

SDX

PDCU

SD

SDX

DS

PETMRI

8 8

10 10 10 10

1. POWER CONDITIONING DISTRIBUTION UNIT FURNISHED BY OTHERS

AND INSTALLED BY CONTRACTOR. GROUND TO BUILDING

STEEL.

2. FEEDER NOT TO EXCEED 20FT. PROVIDE A 6' PIGTAIL AT THE XVI

GENERATOR.

3. PROVIDE A 6' PIGTAIL AT THE END OF EXIT FB2.

4. PROVIDE ALL NECESSARY MOUNTING HARDWARE AND

ACCESSORIES TO RETROFIT NEW BREAKER INTO EXISTING PANEL.

5. 200A 3PH 480/277V ELECTRIC RECEPTACLE.

6. EPO CIRCUIT TO BE NORMALLY CLOSED, WIRED IN SERIES,

CONNECTED TO CT PDC UPS ONLY.

7. EXISTING CHILLERS TO BE RELOCATED. REFER TO NEW ROOF PLAN

FOR APPROXIMATE LOCATION.

8. EC TO VERIFY EXISTING CONDUCTOR TYPE AND SIZE AND EXTEND

TO NEW LOCATION.

9. PROVIDE 3 #10 ROM ACCELERATOR UNIT TO PDC FOR ION PUMP.

10. PROVIDE OVERSIZED LUGS FOR CONDUCTOR SIZE SHOWN AND A

MINIMUM AIC RATING OF 65K AMPS.

1200AMPS @

MAIN SECTION:

DISTRIBUTION SECTION:

MIN AIC RATING =

EATON POW-R-LINE PRL4B

200AF

200AT

3P

UL

B02-3

UL

BO2-4

400AMPS @

MAIN SECTION:

DISTRIBUTION SECTION:

MIN AIC RATING =

CUTLER-HAMMER PRL4

ELHCR

BO2-1

1200AMPS @

MAIN SECTION:

DISTRIBUTION SECTION:

MIN AIC RATING =

400AF

100AT

3P

EULQ

BO2-1

FED FROM SG-3EQ 100AF

90AT

3P

150AT

3P

UL

B00-1

1200AMPS @

MAIN SECTION:

DISTRIBUTION SECTION:

MIN AIC RATING =

WESTINGHOUSE CDP-3PH-4W

FED FROM SG-3N

50AT

3P

CHILLER

70AT

3P

70AT

3P

800AMPS @

MAIN SECTION:

DISTRIBUTION SECTION:

MIN AIC RATING =

CUTLER-HAMMER PRL4

200AT

3P

FED FROM SG-2CR

EULCR

B00-2

60AS

3P

200AS

3P

EULQ

BO2-3

1200AF

1200AS

1200AT

3P

200AF

40AT

3P

40AT

3P

125AT

3P

PDC

150AF150AF225AF

800AF

800AT

3PEDH-212-CR-2

FED FROM EDH-9

MP

SPD

FB2-1

GEN-1

70AT

3P

70AT

3P

40AT

3P

40AT

3P

150AF150AF

FB2-2

GEN-2

EUL-CR

B00-1

200AS

3P

400AF

225AT

3P

EUH-Q

B00-1

EUL-Q

B00-1

PETMRI

4 4 4 4 4

1200AMPS @

MAIN SECTION:

DISTRIBUTION SECTION:

MIN AIC RATING =

EATON POW-R-LINE PRL4B

FED FROM SWB-2

150AT

3P

UH

B00-1

1200AF

1200AS

1200AT

3P

200AF

600AT

3P

600AF

___AS

3P

HEX-ACCH-L1

35AT

3P

CHILLER

___AS

3P

HEX-ACCH-L2

9 9

150AT 150AT 150AT 150AT

DL-B01-1

EDH-CR-B02-1

EDH-304-Q-3

ET/7

DH-BO2-1

EDH-211-CR-7

ECRT-B00-2

KEYED NOTES -

ECRT-1-B0225

EQRT-1-B0225

DH-B01-1

T/2

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

GUIDON DESIGN INC.

905 N. CAPITOL AVE. SUITE 100 | INDIANAPOLIS, IN. 46204

317.800.6388 | WWW.GUIDONDESIGN.COM

SUSTAINABLE ARCHITECTURE + ENGINEERING

PROJECT LEAD

Architect, Structural Engineer, Civil Engineer

FULLY-SPRINKLERED

PHASING IS DEFINED IN PROJECT SPECIFICATIONS AND PHASING PLANS. CONTRACTOR

TO COORDINATE THE FULL SCOPE OF WORK TO BE PHASED SO AS TO NOT IMPACT THE

OPERATION OF SURROUNDING SPACES OR PREVIOUS PHASES. SPECIFIC COORDINATION

SHOULD BE GIVEN FOR DEMOLITION, UTILITY ROUTING AND SHUTDOWNS.

C U s e rs

\p e rm o \D o c u m e n ts

\7

.0

E

M

P e re z ri n g d u .c o m

.r v t

/2 /2

:2

:1

P

M

ES401

ONE LINE DIAGRAM CONSTRUCT NEW RADIATION

ONCOLOGY SUITE

MILWAUKEE VAMC

695-404

04 OCTOBER 2018 MGM MTP

FINAL CONSTRUCTION

DOCUMENTS BLDG 111

NOT TO SCALEES401

1 ONE LINE DIAGRAM

17400 West Capitol Drive, Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778.2360 / r-d@ringdu.com

R&D Project No.:

THIS BAR IS 1" LONG.

IF IT MEASURES ANYTHING OTHER THAN 1"

2" 1/4"

-1

/2

OUTLET VOICE/DATA

3/4" CONDUIT

3/4" CONDUIT

V D

DD

RECEPTACLE

INFO

CIRCUIT

INFO

CIRCUIT

INFO

REQUIRED LABELS FOR ALL RECEPTACLES:

FIRST PART OF LABEL INDICATES RECEPTACLE

INFORMATION SUCH AS RECEPTACLE ID NO, TYPE,

VOLTS, AMPS, PHASE, PANEL BOARD, CIRCUIT NO,

PANEL BOARD ROOM NO.

SECOND PART OF CIRCUIT INDICATES CIRCUIT

INFORMATION SUCH AS IDENTITIY OF RECEPTACLES

ON THE SAME CIRCUIT, PANEL BOARD, AND CIRCUIT

I.D. PROVIDE SECOND LABEL AS REQUIRED.

ALL LABELS TO BE 1/16" PHENOLIC PLASTIC,

RECEPTACLES ON EMERGENCY POWER TO USE RED

PLASTIC WITH WHITE LETTERING. RECEPTACLES ON

NORMAL POWER TO USE BLACK PLASTIC WITH WHITE

LETTERING TO BE 3/16" HIGH. LOCATION OF LABELS

AS SHOWN OR AS DIRECTED BY COR. SCREW LABELS

TO WALL WITH #6 X3/4" LENGTH SCREW, SET IN PLASTIC

DRYWALL TYPE

ANCHORS.

TYPICAL

RECEPTACLE

LENGTH AS REQUIRED

DETAIL NOTES -

KEYED NOTES -

1.

2.

3.

1.

2.

3.

4.

5.

6.

METAL CHANNEL STRUT SUPPORT LONGER THAN 36"

SHALL BE INSTALLED WITH A CENTER SUPPORT ROD.

FASTEN THREADED ROD TO STRUCTURE BY APPROVED

METHOD PER SPECIFICATION 26 0533, RACEWAYS AND

BOXES FOR ELECTRICAL SYSTEMS. FIELD VERIFY EXACT

CONDITIONS.

FOR TRAPEZE INSTALLATIONS IN SEISMIC AREAS REFER

TO SPECIFICATION SECTION 10 05 41, SEISMIC

RESTRAINT

REQUIREMENTS FOR NON-STRUCTURAL COMPONENTS.

3/8" MIN GALVANIZED THREADED ROD, TYP.

LOCKING SQUARE WASHER & LOCKNUT

INTEGRAL GALVANIZED LIPPED STEEL MOUNTING

CHANNEL

WASHER & LOCKNUT

REFER TO PLANS FOR QUANTITY & SIZE OF CONDUITS

CONDUIT CLAMP. SIZE AS REQUIRED

KEYED NOTES -

3/8" MAX

[10mm]

1.

2.

3.

4.

5.

6.

7.

8.

9.

FLOOR SLAB, TYPICAL

FIRESTOP SEALANT PER SECTION 07 84 00,

FIRESTOPPING

CONDUIT, TYPICAL

MINERAL WOOL (FIRMLY PACKED)

INTEGRAL GALVANIZED LIPPED STEAL MOUNTING

CHANNEL, TYPICAL

STEEL EXPANSION ANCHOR, TYPICAL

CONDUIT COMPRESSION FITTING, TYPICAL

SPRING NUT, TYPICAL

JUNCTION BOX (SIZE AS REQUIRED)

DETAIL NOTES -

KEYED NOTES -

1.

2.

3.

4.

8 9

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

MAINTAIN A MINIMUM CLEARANCE OF 12" [308mm] ON ALL

SIDES OF ROOF PENETRATION FROM WALLS, CURBS,

AND OTHER PROJECTIONS TO FACILITATE PROPER

FLASHING.

FLANGES OF ADJACENT FLASHINGS SHALL NOT BE CUT

OR OVERLAPPED.

VERIFY ROOF & STRUCTURAL SYSTEM WITH ARCHITECT.

COORDINATE FLASHING INSTALLATION WITH ROOFING

CONTRACTOR TO ENSURE PROPER METHODS &

MATERIALS ARE USED TO MAINTAIN ROOF WARRANTY.

STAINLESS CLAMP, TYP.

PREFABRICATED RUBBER BOOT CAP WITH GRADUATED

STEPS & WEATHER-PROOF PRESSURE SEAL TO COLLAR

SEALANT AT PENETRATION TO MEMBRANE JUNCTURE BY

ROOFING CONTRACTOR

ROOF MEMBRANE

ROOF

WATER CUT-OFF MASTIC COMPATIBLE WITH ROOF

MEMBRANE

CONDUIT CLAMP. SIZE AS REQUIRED

SEAL-OFF FITTING, TYP.

CONDUIT, TYP.

BATT INSULATION

PREFABRICATED FORMED 0.06" THICK ALUMINUM

FLASHING ROUND COLLAR WITH MIN. 3" WIDE FLANGE.

ATTACH TO ROOF PER MANUFACTURER'S INSTRUCTIONS

MULTIPLE MEMBRANE STRIPPING PLIES FEATHERED AT

FIELD OF ROOF BY ROOFING CONTRACTOR. PRIME

FLANGE BEFORE STRIPPING.

STEEL EXPANSION ANCHOR

3/8" MIN GALVANIZED THREADED ROD, TYP.

LOCKING SQUARE WASHER & LOCKNUT

CONDUIT CLAMP. SIZE AS REQUIRED

INTEGRAL GALVANIZED LIPPED STEEL MOUNTING

CHANNEL

M A

X

[3 m m

M A

X

[4 m m

A

A

SECTION "A-A"

ELEVATION

KEYED NOTES -

1.

2.

3.

4.

5.

CAST METAL "WHILE-IN-USE" WP COVER(S) &

RECEPTACLE(S).

RIGID STEEL CONDUIT FOR SUPPORT PER N.E.C. ART.

RIGID STEEL CONDUIT FOR WIRING

ROOF PENETRATION AND CONDUIT SUPPORT PER

SD260533-04

CAST METAL, 2-GANG, NEMA 3R JUNCTION BOX WITH

THREADED HUBS.

(1)#6 3/4" C.

INDIVIDUAL PATIENT

CARE VICINITY "A"

INDIVIDUAL PATIENT

CARE VICINITY "B"

120V &/OR 277V

OTHER

BRANCH(ES)

120V &/OR 277V

CRITICAL CARE

BRANCH

120V &/OR 277V

NORMAL

POWER

BRANCH

120V &/OR 277V

CRITICAL CARE

BRANCH

120V &/OR

277V OTHER

BRANCH(ES)

DETAIL NOTES -

KEYED NOTES -

(1)#6 3/4" C.

(1)#6 3/4" C.

(1)#6 3/4" C.

2 2 2 2

1 1

IF THIS IS A REMODEL OF AN EXISTING SPACE, THE EC

SHALL VERIFY THAT THE EXISTING PANELBOARDS

SERVING ALL INDIVIDUAL PATIENT VICINITIES WITHIN

THE CONSTRUCTION LIMITS OF THIS PROJECT ARE

BONDED WITH A MINIMUM OF A #6 INSULATED COPPER

CONDUCTOR. IF THEY ARE NOT, THE EC SHALL

PROVIDE PANELBOARD BONDING AS DESCRIBED

HEREIN.

SEE NEC 517-3 FOR THE DEFINITION OF A PATIENT

VICINITY.

ALL PANELBOARDS SERVING LIGHTING FIXTURES THAT

FALL WITHIN THE FOOTPRINT OF THE PATIENT VICINITY

SHALL BE INCLUDED IN THE PANELBOARD BONDING

SYSTEM.

1.

2.

3.

CIRCUITS SERVING A COMMON INDIVIDUAL PATIENT

VICINITY.

PROVIDE BONDING CONDUCTOR BETWEEN THE

GROUND BUSSES OF ALL PANELS SERVING A COMMON

INDIVIDUAL PATIENT VICINITY AS REQUIRED BY NEC

517-14 AND AS DEFINED HEREIN. EACH CONDUCTOR

SHALL BE BONDED TO THE RACEWAY AT BOTH ENDS.

EXAMPLE OF PANELS BONDED TOGETHER FOR

INDIVIDUAL PATIENT VICINITY "A".

EXAMPLE OF PANELS BONDED TOGETHER FOR

INDIVIDUAL PATIENT VICINITY "B".

PANELBOARD GROUND BUS. TYPICAL.

1.

2.

3.

4.

5.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

GUIDON DESIGN INC.

905 N. CAPITOL AVE. SUITE 100 | INDIANAPOLIS, IN. 46204

317.800.6388 | WWW.GUIDONDESIGN.COM

SUSTAINABLE ARCHITECTURE + ENGINEERING

PROJECT LEAD

Architect, Structural Engineer, Civil Engineer

FULLY-SPRINKLERED

PHASING IS DEFINED IN PROJECT SPECIFICATIONS AND PHASING PLANS. CONTRACTOR

TO COORDINATE THE FULL SCOPE OF WORK TO BE PHASED SO AS TO NOT IMPACT THE

OPERATION OF SURROUNDING SPACES OR PREVIOUS PHASES. SPECIFIC COORDINATION

SHOULD BE GIVEN FOR DEMOLITION, UTILITY ROUTING AND SHUTDOWNS.

C U s e rs

\p e rm o \D o c u m e n ts

\7

.0

E

M

P e re z ri n g d u .c o m

.r v t

/2 /2

:2

:4

P

M

ES500

ELECTRICAL DETAILS CONSTRUCT NEW RADIATION

ONCOLOGY SUITE

MILWAUKEE VAMC

695-404

04 OCTOBER 2018 MGM MTP

FINAL CONSTRUCTION

DOCUMENTS BLDG 111

NOT TO SCALEES500

1 CONDUIT TRAPEZE MOUNTING DETAIL

NOT TO SCALEES500

2 FLOOR SLAB PENETRATION DETAIL

NOT TO SCALEES500

4 ROOF PENETRATION DETAIL

NOT TO SCALEES500

5 RECEPTACLE ROOF MOUNTING DETAIL

NOT TO SCALEES500

3 PANELBOARD BONDING DETAIL

17400 West Capitol Drive, Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778.2360 / r-d@ringdu.com

R&D Project No.:

THIS BAR IS 1" LONG.

IF IT MEASURES ANYTHING OTHER THAN 1"

ADJUST SCALE ACCORDINGLY.

217164.00

NOT TO SCALEES500

6 RECEPTACLE DETAIL

D

D

D

D

D

SDX

SD

PDCUGEN

CLIENT INTERFACE TERMINAL BOX (CITB) SCHEMATIC

CITB

CUSTOMER VAULT DOOR

DOOR 1 SWITCH - D1A

15 24 VAC FROM MACHINE

24 VAC FROM MACHINE

CUSTOMER FASCIA DOOR

DOOR 2B SWITCH

CUSTOMER FASCIA DOOR

DOOR 2B SWITCH

24 VAC FROM MACHINE

24 VAC FROM MACHINE

24 VAC FROM MACHINE

24 VAC FROM MACHINE

MAXIMUM PERMISSIBLE

VOLTAGE DROP ACROSS

0.25 V AT 5 AMPS

ANY TWO TERMINALS

CUSTOMER FASCIA DOOR

DOOR 2A SWITCH

CUSTOMER FASCIA DOOR

DOOR 2A SWITCH

24 VAC FROM MACHINE

24 VAC FROM MACHINE

24 VAC FROM MACHINE

24 VAC FROM MACHINE

MOTION STOP SWITCHES, NUMBER AS

REQUIRED (SERIES CONNECTION)

24 VAC FROM MACHINE

24 VAC RETURN TO MACHINE

MAX PERMISSIBLE VOLT DROP

1V AT 5 AMPS

L

N

TO CITB POWER SUPPLY

VOLTAGE CURRENT

TO MACHINE

CHILLER

START

REMOTE

SUPPLY SYSTEM

CHILLED WATER

RELAY

(RELAY BY

CONTRACTOR)

28 28

FROM…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it.