36E77619R0011-0002008.pdf

PDF 225 KB Posted

Attached to
Construct New Radiation Oncology Suite Milwaukee VAMC (Minor)
Solicitation number
36E77619R0011
Issued by

About this file

36E77619R0011 0002 ET600 - TECHNOLOGY SCHEDULES.pdf

View the file

Other files

File Type Posted
36E77619R0011-0007001.pdf PDF
36E77619R0011-0007000.docx DOCX document
36E77619R0011-0006003.pdf PDF
36E77619R0011-0006000.docx DOCX document
36E77619R0011-0006001.docx DOCX document
36E77619R0011-0006002.pdf PDF
36E77619R0011-0005005.pdf PDF
36E77619R0011-0005006.pdf PDF
36E77619R0011-0005003.pdf PDF
36E77619R0011-0005002.pdf PDF
36E77619R0011-0005004.pdf PDF
36E77619R0011-0005000.docx DOCX document
36E77619R0011-0005001.docx DOCX document
36E77619R0011-0004000.docx DOCX document
36E77619R0011-0004002.pdf PDF
36E77619R0011-0004003.pdf PDF
36E77619R0011-0004001.pdf PDF
36E77619R0011-0003000.docx DOCX document
36E77619R0011-0002005.pdf PDF
36E77619R0011-0002002.pdf PDF
36E77619R0011-0002007.pdf PDF
36E77619R0011-0002010.docx DOCX document
36E77619R0011-0002000.docx DOCX document
36E77619R0011-0002001.pdf PDF
36E77619R0011-0002009.pdf PDF
36E77619R0011-0002003.docx DOCX document
36E77619R0011-0002006.pdf PDF
36E77619R0011-0002004.pdf PDF
36E77619R0011-0001000.docx DOCX document
36E77619R0011-0001001.pdf PDF
36E77619R0011-000.docx DOCX document
36E77619R0011-005.pdf PDF
36E77619R0011-007.pdf PDF
36E77619R0011-012.pdf PDF
36E77619R0011-003.pdf PDF
36E77619R0011-008.pdf PDF
36E77619R0011-002.pdf PDF
36E77619R0011-001.pdf PDF
36E77619R0011-009.docx DOCX document
36E77619R0011-006.pdf PDF
36E77619R0011-010.docx DOCX document
36E77619R0011-011.pdf PDF
36E77619R0011-004.pdf PDF
36E77619R0011_1.docx DOCX document
Show all 44

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MONITOR MODULE SCHEDULE

DES. DEVICE MONITORED FIRE ALARM SYSTEM RESPONSE

DPFS

DRY PIPE SYSTEM

- FLOW SWITCH

INITIATES AN ALARM SIGNAL ON THE FIRE ALARM SYSTEM.

DPLP

DRY PIPE SYSTEM

- LOW PRESSURE SWITCH

INITIATES A SUPERVISORY SIGNAL ON THE FIRE ALARM SYSTEM.

DPTS

DRY PIPE SYSTEM

- TAMPER SWITCH

INITIATES A SUPERVISORY SIGNAL ON THE FIRE ALARM SYSTEM.

FSB-1

FLOW SWITCH

-BASEMENT FLOOR

INITIATES AN ALARM SIGNAL ON THE FIRE ALARM SYSTEM.

TSB-1

TAMPER SWITCH

- BASEMENT FLOOR

INITIATES A SUPERVISORY SIGNAL ON THE FIRE ALARM SYSTEM.

MONITOR MODULE SCHEDULE NOTES:

1.

HORIZONTAL CABLING SCHEDULE

DES

VOICE DATA OTHER FACEPLATE

DETAIL

NOTES

QUANTITY TYPE CABLE COLOR JACK COLOR QUANTITY TYPE CABLE COLOR JACK COLOR QUANTITY TYPE CABLE COLOR JACK COLOR

W 1 CAT5E BLUE WALL MT. -/ET500

1D 1 CAT5E WHITE BLACK -/ET500

2D 2 CAT5E WHITE BLACK -/ET500

2V2D 2 CAT5E BLUE ORANGE 2 CAT5E WHITE BLACK -/ET500

1V3D 1 CAT5E BLUE ORANGE 3 CAT5E WHITE BLACK -/ET500

1V4D 1 CAT5E BLUE ORANGE 4 CAT5E WHITE BLACK -/ET500

TV 1 CAT5E WHITE BLACK 1 RG6 BLACK - -/ET500

WAP 1 CAT5E GRAY BLACK -/ET500

CABLE SPECIFICATIONS NOTES:

CAMERA SCHEDULE

DES. LOCATION CAMERA TYPE LENS TYPE ENCLOSURE TYPE MOUNT TYPE SEE NOTE

C01 WAITING IP FIXED 2.8MM-12MM VARIFOCAL SMOKED DOME CEILING MOUNTED

C02 WAITING/CHECK-IN/OUT 1800 IP FIXED 2.8MM-12MM VARIFOCAL SMOKED DOME CEILING MOUNTED

C03 WAITING IP FIXED 2.8MM-12MM VARIFOCAL SMOKED DOME CEILING MOUNTED

C04 CORRIDOR C0A12 IP FIXED 2.8MM-12MM VARIFOCAL SMOKED DOME CEILING MOUNTED

C05 CORRIDOR C0A15 IP FIXED 2.8MM-12MM VARIFOCAL SMOKED DOME CEILING MOUNTED

C06 CORRIDOR C0A17 IP FIXED 2.8MM-12MM VARIFOCAL SMOKED DOME CEILING MOUNTED

C07 PET MRI VESTIBULE IP FIXED 2.8MM-12MM VARIFOCAL SMOKED DOME CEILING MOUNTED

C08 OUTDOORS IP FIXED 2.8MM-12MM VARIFOCAL SMOKED DOME CEILING MOUNTED

CAMERA SCHEDULE NOTES:

1.

CONTROL MODULE SCHEDULE

DES INTERFACED WITH ACTIVATION DESCRIPTION

AHU

AHU-RADIOLOGY TEMPERATURE

CONTROL PANEL

INITIATES UNIT SHUT DOWN PROCEDURES UPON ALARM SIGNAL FROM UNIT DUCT SMOKE DETECTORS.

DI DOOR INTERFACE RELEASE SECURED DOOR UPON ALARM SIGNAL FROM FIRE ALARM SYSTEM.

CONTROL MODULE SCHEDULE NOTES:

1.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

GUIDON DESIGN INC.

905 N. CAPITOL AVE. SUITE 100 | INDIANAPOLIS, IN. 46204

317.800.6388 | WWW.GUIDONDESIGN.COM

SUSTAINABLE ARCHITECTURE + ENGINEERING

PROJECT LEAD

Architect, Structural Engineer, Civil Engineer

FULLY-SPRINKLERED

PHASING IS DEFINED IN PROJECT SPECIFICATIONS AND PHASING PLANS. CONTRACTOR

TO COORDINATE THE FULL SCOPE OF WORK TO BE PHASED SO AS TO NOT IMPACT THE

OPERATION OF SURROUNDING SPACES OR PREVIOUS PHASES. SPECIFIC COORDINATION

SHOULD BE GIVEN FOR DEMOLITION, UTILITY ROUTING AND SHUTDOWNS.

C U s e rs

\p e rm o \D o c u m e n ts

\7

.0

E

M

P e re z ri n g d u .c o m

.r v t

/2

/2

:4

:4

A

M

ET600

TECHNOLOGY SCHEDULES CONSTRUCT NEW RADIATION

ONCOLOGY SUITE

MILWAUKEE VAMC

695-404

04 OCTOBER 2018 MGM MTP

FINAL CONSTRUCTION

DOCUMENTS BLDG 111

17400 West Capitol Drive, Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778.2360 / r-d@ringdu.com

R&D Project No.:

THIS BAR IS 1" LONG.

IF IT MEASURES ANYTHING OTHER THAN 1"

ADJUST SCALE ACCORDINGLY.

217164.00Revisions: Date:

ADDENDUM 1 02/22/2019

Sheets
ET101 - PARTIAL BASEMENT FLOOR PLAN - TECHNOLOGY
ET500 - TECHNOLOGY DETAILS
ET600 - TECHNOLOGY SCHEDULES