36E77619R0011-0002006.pdf
PDF 928 KB Posted
- Solicitation number
- 36E77619R0011
About this file
36E77619R0011 0002 ET101 - PARTIAL BASEMENT FLOOR PLAN - TECHNOLOGY.pdf
View the file
Other files
Show all 44
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A67/36G A67/36G
D H
D H
D H
S
S
N
N
S
S
N F
S
S
S
S S
S
S
S
S S S
S
S
S
S S
S
S
S
S
S
S
S
S
S
SS
S
S
N N N N
N
N
N C
S
N
N
N
FA
C
P
N
N
D
N NNN
N
N
J
J
J
J
J
J
J
J
J
J
S
NCS
N
N
N
N
N
N
S
S
S
S
S
S
S
N C
T
SS
S
S
S N
N
N
S S
D
S
D
S
S
S
FATC
J
J
S
S
S S
S
S
S
S
S
S
S
SS
D
D D
D
D
D
F
S
C DB
EXAM
B0205 EXAM
B0206
EXAM
B0209
TOILET
B0212
NURSE PRACTITIONER
B0213
LEAD PHYSICIAN
B0214
TOILET
B0217
CLEAN
B0215
HAC
B0218 CONFERENCE ROOM
B0220
ADMIN
B0216
CANCER CARE
B0228 RESEARCH
B0229
BLOCK MOLD FILM
PROCESS STORAGE
B0230
EXAM
B0211
NURSE
WORKSTATIONS
B0208
RESIDENT
WORKSTATIONS
B0227
RECEPTION
B0201
WAITING
B0200
STAFF LOUNGE
B0221
PHYSICIST
WORKROOM
B0222
LEAD PHYSICIST
B0223
CONTROL ROOM
B0014
CONTROL ROOM
B0011
CONSULT / EXAM
B0204
VITALS
B0203
LOCKERS
B0219
ADMIN
B0224
EXAM
B0210
PHYSICIAN
WORKSTATIONS
B0226
PROCEDURE HOLDING
BAY
B0207
CORRIDOR
C0A15
CORRIDOR
C0A14
CORRIDOR
C0A13
CORRIDOR
C0A12CORRIDOR
C0A10
MECH / ELEC
B0225
SCHEDULERS
B0202
CORRIDOR
C0A17
LOGISTICS - CLEAN
B0234
WAITING ROOM
B0009 DRESSING ROOM
B0010
CT STORAGE
B0006
CT EQUIPMENT
B0005
CT SCANNER
B0004
DRESSING / TOILET
B0008
DRESSING / TOILET
B0007
CT ENTRY ROOM
B0003
CONTROL ROOM
B0002
DOSIMETRY
B0001
SOILED
B0232 CORRIDOR
C0A15
PHYSICS STORAGE
B0233
D,1V3D
C,1V3D
D,2D
C,1V3D
S,1V3D C,1V3D
D,1V3D
D,1V3D D,1V3D D,1V3D D,1V3D D,1V3D
D,1V3D
C,1V3D D,1V3D
D,1V3D
D,1V3D
D,1V3D
C,1V3D C,1V3D
D,1V3D
D,1V3D D,1V3D
D,1V3D D,1V3D
D,1V3D
D,1V3D
D,1V3D
D,1V3D
D,1V4D
S,1D
D,1V4D D,1V4D D,1V4D
D,1V4D
D,1V3D D,1V3D
CR/HP
CR/HP
CR/HP
SV1
SV1
SV2
ET300
ET300
ET301
CR
CR
CR
DB
DB
DB
DB DB DB DB
DB
W
D,2D
SV1
SV1
SV1SV1
SV1
SV1
SV1 SV1
SV1
SV1
CR/HP CR/HP
CR/HP
CR/HP
CR/HP
CR/DP
CR/HP
CR/HP
CR/HPCR/HP
CR/HP
CR/HP
CR/HPCR/HP
CR/HP
E
E
E E E
E
D
D
D
SV2
VO1
VO1
VO1
VO1
E
E
VO1
D D D
D
D
D
D,1V3D D,1V3D
SV2
VO1
SV1SV1
VO1
VO1
SV2
VO1
SV1
SV1
SV1
LINAC 1
B0013
LINAC 2
B0012
D,1V3D D,1V3D
S,1V3D
CR/HP
E
D
D
D
D
E
CR/HP
CR/HP
EX
CR/HP
CR/HP
CR/HP
CR/HP
CR/HP
NEW ACCESS
CONTROL
PANEL
NEW
C01
C05
ET101
ET102
ET101
ET102
X28
X27
X26
X25
X24
X23
X22
X21
X20
X19
XBXCXDXEXF
XG
E FG
A
C05
DB
E
D
D
C04
CR
CR
TV,S
C,1V3D
S ,1
V D
DB
DB
S,1D
S,1D
D,1V3D
D,1V3D
D,1V3D
D,1V3D
D,1V3D
D,1V3D
D,1V3D
S,2D
60"
C,1V3D
D,1V3D
CLEAN LINENS
B0231
LOGISTICS - DIRTY
B0235
CR
EXISTING DOOR
EX RACK
EX VOICE
WALL FIELD
EX ACCESS
CONTROL
PANEL 48
VO1VO1
VO1
MM
FSB-1
MM
TSB-1
EX CABLE
TV WALL
FIELD
C,1V4D
C,1V4D
C,1V4D C,1V4D
D,1V4D
C,1V4D
C,1V4D
D,1V4D
CR/DP
CR/DP
CR/DP CR/DP
CR/DP
CR/DP
CR/DP
C,1V3D
CR/DP
D,1V3D
CR/HP
8 9
8 9
CR/DP
CR/HP
C02
HW-3
HW-20
HW-9
HW-9
HW-21
HW-9
HW-22
HW-2
HW-2
D,1D
SO/C
P P
CM
DI
P
P
CM
DI
PP
CM
DI
P
P
CM
DI
F,1V3D
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP WAP
WAP
WAP
WAP
WAP
WAP
AHU
UNIT/RETURN
AHU
UNIT/SUPPLY
AHU
CM
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
GUIDON DESIGN INC.
905 N. CAPITOL AVE. SUITE 100 | INDIANAPOLIS, IN. 46204
317.800.6388 | WWW.GUIDONDESIGN.COM
SUSTAINABLE ARCHITECTURE + ENGINEERING
PROJECT LEAD
Architect, Structural Engineer, Civil Engineer
FULLY-SPRINKLERED
PHASING IS DEFINED IN PROJECT SPECIFICATIONS AND PHASING PLANS. CONTRACTOR
TO COORDINATE THE FULL SCOPE OF WORK TO BE PHASED SO AS TO NOT IMPACT THE
OPERATION OF SURROUNDING SPACES OR PREVIOUS PHASES. SPECIFIC COORDINATION
SHOULD BE GIVEN FOR DEMOLITION, UTILITY ROUTING AND SHUTDOWNS.
C U s e rs
\p e rm o \D o c u m e n ts
\7
.0
E
M
P e re z ri n g d u .c o m
.r v t
/2
/2
:4
:4
A
M
ET101
PARTIAL BASEMENT FLOOR PLAN
- TECHNOLOGY
CONSTRUCT NEW RADIATION
ONCOLOGY SUITE
MILWAUKEE VAMC
695-404
04 OCTOBER 2018 MGM MTP
FINAL CONSTRUCTION
DOCUMENTS BLDG 111
1/8" = 1'-0"ET101
1 PARTIAL BASEMENT FLOOR PLAN - TECHNOLOGY SOUTH
1" = 100'-0"
KEY PLAN SOUTH
N
N
1.
2.
3.
DETAIL NOTES -
KEYED NOTES -
EC SHALL REFER TO ARCHITECTURAL
FLOOR PLANS, REFLECTED CEILING PLANS
AND ELEVATIONS FOR EXACT LOCATIONS
AND MOUNTING HEIGHTS.
REFER TO ARCHITECTURAL PHASING
PLANS FOR EXACT EXTENT OF
CONSTRUCTION.
COORDINATE EXACT WAP LOCATIONS PER
VA IT SURVEY.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
PROVIDE ROUGH-IN FOR FUTURE NURSE
CALL.
NEW LOCATION OF EXISTING PAGING
EQUIPMENT. RECONNECT EXISTING PHONE
AND OTHER INPUT TO MATCH EXISTING.
COORDINATE SHUTDOWNS WITH OWNER.
EXISTING TELECOM ROOM SERVING AREA
OF WORK. ALL VOICE/DATA CABLE SHALL
BE TERMINATED IN THIS ROOM.
PROVIDE DATA CONNECTION FOR NEW
ACCESS CONTROL PANEL. ALL ACCESS
CONTROLED DOORS FOR THIS PROJECT
SHALL BE SERVED FROM THIS PANEL.
CABLE SERVING TELEVISIONS WITHIN THE
AREA OF WORK SHALL BE HOME RUN
BACK TO EQUIPMENT ON THE EXTISTING
CABLE TV WALL FIELD.
EXISTING FIRE ALARM SYSTEM POWER
SUPPLY (NAC) PANELS TO REMAIN.
PROVIDE (1) 1" CONDUIT FROM BOX ABOVE
COUNTER TO MONITOR. VERIFY EXACT
LOCATION WITH VA IT PRIOR TO ROUGH IN.
THE BOUNDARY INDICATED IS THE SMOKE
ZONE SEPARATION FOR THE AREA OF
WORK. FIRE ALARM CIRCUITS SHALL
FOLLOW NFPA 72 LEVEL 3 SURVIVABLE
CIRCUIT REQUIREMENTS FROM THEIR
POINT OF ORIGEN UNTIL THEY ENTER THE
AREA OF WORK SMOKE ZONE.
NOTIFICATION CIRCUITS SHALL BE
DEDICATED TO THE SMOKE ZONE WITHIN
THE AREA OF WORK. NOTIFCATION
DEVICES OUTSIDE OF THE SMOKE ZONE
SERVING THE AREA OF WORK MAY USE
THE EXISTING CIRCUITS SERVING THOSE
AREAS.
THE BOUNDARY INDICATED IS BASED ON
INFORMATION AVAILABLE DURING
DESIGN. CONTRACTOR SHALL
COORDINATE FINAL BOUNDARY WITH
ARCHITECTURAL LIFE SAFETY PLANS ("G"
SERIES PLANS).
PROVIDE A REMOTE RELEASE BUTTON TO
RELEASE DOOR B0200B.
APPROXIMATE LOCATION OF DUCT SMOKE
DETECTORS ON ROOF TOP AIR HANDLING
UNIT.
17400 West Capitol Drive, Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778.2360 / r-d@ringdu.com
R&D Project No.:
THIS BAR IS 1" LONG.
IF IT MEASURES ANYTHING OTHER THAN 1"
ADJUST SCALE ACCORDINGLY.
217164.00Revisions: Date:
ADDENDUM 1 02/22/2019
| Sheets |
| ET101 - PARTIAL BASEMENT FLOOR PLAN - TECHNOLOGY |
| ET500 - TECHNOLOGY DETAILS |
| ET600 - TECHNOLOGY SCHEDULES |
File details come from the government source that posted it.