Attachment 08 OMAHA VA EHRM_BID SET_TECHNOLOGY - Drawing.pdf

PDF 28 MB Posted

Attached to
Y1DA--Copy of EHRM Infrastructure Upgrades - Construction - Omaha VAMC DUPLICATE OF 36C776230036
Solicitation number
36C77623B00361
Issued by

About this file

This file attachment relates to a federal contract solicitation for infrastructure upgrades at the Omaha VA Medical Center. The solicitation number is 36C77623B00361 and is for construction services for the EHRM Infrastructure Upgrades project. The opportunity was issued by the Department of Veterans Affairs Technology Acquisition Center located in Austin, Texas. The solicitation seeks construction services to upgrade technology infrastructure at the Omaha VA Medical Center, including drawings of proposed construction work contained in the attached 28MB PDF file. Responses to the solicitation are due on an unspecified date. The award date and any pricing or set-aside terms are not included in the provided information.

View the file

Other files

File Type Posted
Attachment 01 Question and Answer.docx DOCX document
36C77623B0036-1 0008.docx DOCX document
Attachment 01 Additional Questions and Answers.pdf PDF
Attachment 02 Spec 01 00 00 -2 POP Rev1.pdf PDF
Attachment 04 Additional Drawings.pdf PDF
36C77623B0036-1 0007.docx DOCX document
Attachment 03 Additional Drawing Sheet List.pdf PDF
ATTACHMENT 01 - SPECIFICATIONS SECTION 27 COMMUNICATIONS.zip ZIP file
36C77623B0036-1 0006.docx DOCX document
ATTACHMENT 02 - 09 65 19 19 STATIC DISSIPATIVE TILE.pdf PDF
Attachment 01 Omaha EHRM V21 - RFI Responses.pdf PDF
36C77623B0036-1 0005.docx DOCX document
Attachment 03 Tech Notes 636 704.B01.00 TN001.T.20230726.pdf PDF
Attachment 04 Omaha EHRM Addendum Mech Drawings.pdf PDF
Attachment 02 09 65 16 Resiliant Tile Flooring.pdf PDF
36C77623B0036-1 0004.docx DOCX document
Davis Bacon Wage Determinations.pdf PDF
36C77623B0036-1 0003.docx DOCX document
36C77623B0036-1 0002.docx DOCX document
Attachment 1 Site Visit Sign In EHRM Infrastructure Upgrades Construction.pdf PDF
36C77623B0036-1 0001.docx DOCX document
Attachment 09 VA-Omaha EHRM Civil_20230515 - Drawing.pdf PDF
Attachment 06 Omaha EHRM Structural_20230515 - Drawing.pdf PDF
Attachment 03 Specification vol 1 Rev1.pdf PDF
Attachment 07 OMAHA VA EHRM_BID SET_ELECTRICAL - Drawing.pdf PDF
Attachment 04 OMAHA VA EHRM_BID SET_ARCHITECTURAL - drawings.pdf PDF
Attachment 05 OMAHA VA EHRM_BID SET_MECHANICAL - Drawing (1).pdf PDF
Attachment 14 Specification Vol 2 Rev1.pdf PDF
Attachment 02 Omaha EHRM 100 Narrative Mechanical (2).pdf PDF
Attachment 02 Omaha EHRM 100 Narrative Mechanical.pdf PDF
Attachment 01 Omaha EHRM 100 Narrative Elec Revised.pdf PDF
Attachment 16 Service Contract Wage Determinations.gov.pdf PDF
Attachment 10 DBA Wage Determination 4.13.2023.gov.pdf PDF
Attachment 15 HEFP SEP SOP Process Flow Data Center Phase v1.0.pdf PDF
Attachment 13 - Site Visit EHRM Minor Construction Project- Omaha.docx DOCX document
Attachment 11 - Contractor Safety - Environmental Form.docx DOCX document
Attachment 12 - Limitations on Subcontracting - Construction.docx DOCX document
36C77623B0036-1_1.docx DOCX document
Show all 38

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TECHNOLOGY SYMBOL LIST

SYMBOL: DESCRIPTION: NOTE:

EQUIPMENT

LIST ABBREV.:

#D

W

#D#V 1., 3.

WALL INFORMATION OUTLET, COMBINATION

TELEPHONE/DATA COMMUNICATION

SC-IO-W

1., 3.WALL INFORMATION OUTLET, WALL TELEPHONESC-IO-W

1., 3.

FLOOR INFORMATION OUTLET, DATA COMMUNICATION

ONLY

SC-IO-F

#D#V 1., 3.

FLOOR INFORMATION OUTLET, COMBINATION

TELEPHONE/DATA COMMUNICATION

SC-IO-F

#D 1., 3.

CEILING INFORMATION OUTLET, DATA

COMMUNICATION ONLY

SC-IO-C

#D 1., 3.

WALL INFORMATION OUTLET, DATA COMMUNICATION

ONLY

SC-IO-W

M 2.AC-CR2-W CARD ACCESS READER WITH KEYPAD; LETTER

INDICATES AS FOLLOWS:

M = MOUNT

C - CEILING D - DESK F- FLUSH H - HIDDEN M -

MULLION

P - PEDESTAL R - RACK S - SURFACE W - WALL

CSS 2.CONTROLLED SECURITY SCHEME SCHEDULE

IDENTIFIER

N/A

CCTV .

VIDEO SURVEILLANCE CAMERA WITH LENS, WALL

MOUNT OR CEILING MOUNTVS-CM1

TECHNOLOGY ABBREVIATION KEY

MAIN COMPUTER ROOMMCR-#

TELECOMMUNICATIONS ROOM (BUILDING NUMBER - FLOOR - SEQUENCE)TR-#-#-#

ABOVE FINISHED FLOORAFF

BELOW FINISHED CEILINGBFC

CONDUITC

SIMILARSIM

TYPICALTYP

MOUNTING HEIGHT ABOVE FINISHED FLOOR+#

JUNCTION BOXJ-BOX

ABBR: DESCRIPTION:

UNLESS OTHERWISE NOTEDUON

FIELD OF VIEWFOV

DOUBLE POLE DOUBLE THROWDPDT

PAN TILT ZOOMPTZ

POWER OVER ETHERNETPOE

ABOVE FINISHED GRADEAFG

DELAYED EGRESSDE

TELEPHONE EQUIPMENT ROOMTER-#

OFFICE OF INFORMATION TECHNOLOGY (VA)OIT

TECHNOLOGY GENERAL NOTES:

1. ###-### INDICATES TECHNOLOGY EQUIPMENT SCHEDULE ITEM LABELED AS "EQUIPMENT

LIST ABBREVIATION"

2. REFER TO TECHNOLOGY EQUIPMENT SCHEDULE AND SPECIFICATIONS FOR FULL

DESCRIPTIONS AND MANUFACTURERS OF ALL DEVICES.

TECHNOLOGY MOUNTING SUBSCRIPT KEY:

A MOUNT AT +6" TO CENTERLINE ABOVE COUNTER OR BACKSPLASH

H MOUNT ORIENTED HORIZONTALLY

L MOUNT IN CASEWORK

M MOUNT IN MODULAR FURNITURE

S MOUNT IN SURFACE RACEWAY

A SLASH IS USED BETWEEN TWO SUBSCRIPTS, E.G., A/H.

GENERAL NOTES:

1. ALL SYMBOLS AND ABBREVIATIONS LISTED MAY NOT BE APPLICABLE TO THIS PROJECT.

REFER TO THE TECHNOLOGY EQUIPMENT SCHEDULE FOR MORE COMPLETE DESCRIPTION

AND ITEMS.

2. ALL SYMBOLS AND ABBREVIATIONS REFER TO TECHNOLOGY SHEETS ONLY AS DEFINED

ON THE SHEET INDEX. REFER TO THE GENERAL TECHNOLOGY NOTES FOR ADDITIONAL

INFORMATION.

3. ALL SYMBOLS LISTED ABOVE ARE FOR REFERENCE ONLY. REFER TO PLANS AND LINE

TYPE KEY FOR NEW, EXISTING TO REMAIN AND TO BE REMOVED ITEMS FOR ADDITIONAL

INFORMATION.

4. REFER TO RISERS ON SHEETS: TN500, TN501, TN502, TN503, TN504, TN505, TN506, TN507, TN508.

TECHNOLOGY SYMBOL NOTES:

1. "#" INDICATES INFORMATION OUTLET FACEPLATE CONFIGURATION. REFER TO

INFORMATION OUTLET SCHEDULE ON TN600 FOR ADDITIONAL INFORMATION.

2. REFER TO CONTROLLED SECURITY SCHEME (CSS) TYPE SCHEDULE ON TN600 FOR

ADDITIONAL INFORMATION.

3. REFER TO LINE TYPE KEY FOR NEW, EXISTING TO REMAIN, OR DEMO LINE TYPE.

CABLE TRAY, CHANNEL TRAY, BASKET

TRAY

LADDER RACK

WIDTH X HEIGHT

WIDTH X HEIGHT

DIAMETERø C CONDUIT

CONDUIT DOWN

CONDUIT UP OR UP/DOWN

CONDUIT SLEEVE

CONTINUATION

PLAN OR DETAIL NUMBER

PLAN OR DETAIL NAME

PLAN OR DETAIL SCALE

DETAIL REFERRED TO BY SECTION CUT

SHEET DETAIL IS LOCATED ON

NAME

VIEW NAME

1/8" = 1'-0"

M101

SIMSIM

INDICATES SIMILAR DETAIL REFERENCED

IN MULTIPLE LOCATIONS

LEVEL NAME

10'-0" HEIGHT ABOVE

PROJECT 0'-0"

1 INDICATES NOTE USED TO DESCRIBE

ADDITIONAL INFORMATION ABOUT

WORK REQUIRED, SPECIFIC TO THE

SHEET AND/OR DETAIL

N

O R HT

INDICATES DIRECTION OF TRUE NORTH

VIEW KEY

LINE TYPE AND TAG KEY:

NEW WORK BY THIS CONTRACTOR (WIDE LINE)

NEW

EXISTING TO BE REMOVED (SHORT DASHED PATTERN)

NEW UNDERFLOOR OR UNDERGROUND (LONG DASHED PATTERN)

EXISTING TO REMAIN OR WORK BY OTHERS (NARROW LINE)

EXISTING

EXISTING TO BE REMOVED BY OTHERS (SHORT DASHED PATTERN)

EXISTING UNDERFLOOR OR UNDERGROUND (LONG DASHED PATTERN)

HALFTONING DOES NOT MODIFY SCOPE.

'TAG'-E TAGS WITH DASH 'E' INDICATES THE REFERENCED OBJECT IS EXISTING

TAG-1 UNDERLINED TAG INDICATES OBJECT IS IN-SCOPE. IF NEW, ADDITIONAL

INFORMATION IS AVAILABLE IN A SCHEDULE, MATERIAL LIST, OR SYMBOL LIST

INDICATES AN EXISTING SYSTEM'S POINT OF CONNECTION/REMOVAL

T101

SECURITY CONTRACTORS.C.

CIVIL CONTRACTORC.C.

FIRE PROTECTION CONTRACTORF.P.C.

PLUMBING CONTRACTORP.C.

GENERAL CONTRACTORG.C.

MECHANICAL CONTRACTORM.C.

ELECTRICAL CONTRACTORE.C.

CONTRACTOR ABBREVIATION KEY

ABBR: DESCRIPTION:

TECHNOLOGY CONTRACTORT.C.

CONSTRUCTION MANAGERC.M.

SUGGESTED MATRIX OF RESPONSIBILITY

ITEM: SHOWN ON:

FURNISHED

BY:

INSTALLED

BY: NOTES:

TECHNOLOGY ROUGH-IN, REFER TO

TECHNOLOGY EQUIPMENT SCHEDULE

AND SPECIFICATIONS FOR DEFINITION

T-SERIES E.C. E.C. 3. 4.

INFORMATION OUTLET FACEPLATES,

JACKS, AND TERMINATIONS

T-SERIES T.C. T.C.

CONDUIT SLEEVES (WHEN SHOWN ON

DRAWINGS)

T-SERIES E.C. E.C.

CONDUIT SLEEVES (NOT SHOWN BUT

REQUIRED FOR PROPER INSTALLATION

OF SYSTEM)

N/A T.C. T.C. 2. 4.

TELECOMMUNICATION SYSTEMS

ROUGH-IN

T-SERIES E.C. E.C. 1.

TELECOMMUNICATION EQUIPMENT,

CABLING, AND TERMINATIONS

T-SERIES T.C. T.C.

CABLE TRAY (INCLUDING WIRE BASKET

TRAY) REFER TO SPECIFICATION

SECTION 27 05 36 FOR DEFINITION

T-SERIES E.C. E.C.

GROUNDING LUGS ON TECHNOLOGY

EQUIPMENT

T-SERIES T.C. E.C. 6.

BONDING SYSTEM FOR TECHNOLOGY

SYSTEM, REFER TO SPECIFICATION

SECTION 27 05 26 FOR DEFINITION

T-SERIES E.C. E.C. 7. 8.

CONNECTION OF TECHNOLOGY

BONDING SYSTEM TO THE ELECTRICAL

GROUND SYSTEM

T-SERIES E.C. E.C.

LINE VOLTAGE POWER (+120V OR

GREATER)

E-SERIES E.C. E.C.

LINE VOLTAGE POWER (NOT SHOWN

BUT REQUIRED FOR PROPER

INSTALLATION OF SYSTEM)

N/A T.C. E.C. 2. 4.

LINE VOLTAGE POWER FOR DOOR

HARDWARE POWER SUPPLIES

ARCH SPEC E.C. E.C.

LOW VOLTAGE CABLING FOR

TECHNOLOGY SYSTEMS

T-SERIES T.C. T.C.

CABLE HANGERS AND SUPPORTS OR

OTHER CABLE ROUTING METHODS

(OTHER THAN CONDUIT AND CABLE

TRAY)

T-SERIES T.C. T.C. 5.

TECHNOLOGY SERVICE ENTRANCE

CONDUITS, HANDHOLES, AND

MANHOLES

T-SERIES E.C. E.C.

SUGGESTED MATRIX OF RESPONSIBILITY NOTES

1. LOCATIONS OF TELECOMMUNICATIONS ROUGH-INS SHALL BE INDICATED BY THE INFORMATION

OUTLET SYMBOLS ON THE DRAWINGS. REFER TO THE TECHNOLOGY SYMBOL LIST FOR

ADDITIONAL INFORMATION.

2. BASED ON THE INHERENT DIFFERENCES IN PRODUCTS FROM VARIOUS MANUFACTURERS, ALL

REQUIRED EQUIPMENT MAY NOT BE SHOWN ON THE DRAWINGS FOR ALL ACCEPTABLE

MANUFACTURERS.

3. INCLUDES BACKBOXES AND CONDUIT REQUIRED FOR THE TECHNOLOGY SYSTEMS

INSTALLATION. THE E.C. SHALL BASE THE BID ON THE BASIS OF DESIGN SHOWN ON THE

CONTRACT DOCUMENTS.

4. ALL CHANGES TO THE SLEEVES, BACKBOXES, CONDUITS, AND POWER REQUIRED BECAUSE OF

THE T.C.'S SELECTION OF AN ALTERNATE ACCEPTABLE MANUFACTURER OR FROM SYSTEM

CONFIGURATIONS THAT ARE LEFT TO THE CHOICE OF THE CONTRACTOR SHALL BE INCLUDED

IN THE T.C.'S BID. THIS BID SHALL INCLUDE INSTALLATION BY A LICENSED ELECTRICIAN.

5. UNLESS TRADE RULES DICTATE OTHERWISE.

6. FURNISHED AS PART OF THE EQUIPMENT WHEN POSSIBLE, OR FURNISHED TO THE E.C. FOR

INSTALLATION IN THE FIELD.

7. INCLUDES ALL CONDUCTORS, GROUND BARS, AND TERMINATIONS FOR THE COMPLETE

BONDING SYSTEM REQUIRED BY THE SPECIFICATIONS.

8. REFER TO ELECTRICAL DRAWINGS FOR LOCATIONS OF PANELS AND SWITCHBOARDS SHOWN

IN THE TECHNOLOGY BONDING RISER DIAGRAM AND TYPICAL TELECOM ROOM BONDING FLOW

DIAGRAM.

TELECOM ROOM REFERENCES

TELECOM ROOM

DETAIL / SHEET

REFERENCE

FLOOR PLAN

REFERENCE ARCH ROOM NUMBER

MCR-01 2/01-TN100TR-A 01-TN100 B721

TER-01 4/01-TN100TR-D 01-TN100 B024C

TR-104 3/08-TN101 08-TN101 104

TR-109 1/06-TN101TR 06-TN101 109

TR-109D 3/D-TN101 D-TN101 109

TR-202 3/02-TN202 02-TN202 202

TR-1011 N/A ACC-TN101 1011

TR-1205B 4/01-TN101TR-B 01-TN101 1205B

TR-1433 N/A ACC-TN101 1433

TR-1510 3/01-TN101TR-A 01-TN101 1510

TR-1616 1/01-TN101TR-A 01-TN101 1616

TR-1656 1/01-TN101TR-B 01-TN101 1656

TR-2011 N/A ACC-TN102 2011

TR-2255A 4/01-TN102TR 01-TN102 2255A

TR-2433 N/A ACC-TN102 2433

TR-2448 1/01-TN102TR 01-TN102 2448

TR-3254B 1/01-TN103TR 01-TN103 3254B

TR-4374A 1/01-TN104TR 01-TN104 4374A

TR-5414 1/01-TN105TR 01-TN105 5414

TR-6414 1/01-TN106TR 01-TN106 6414

TR-7414 1/01-TN107TR 01-TN107 7414

TR-8414 1/01-TN108TR 01-TN108 8414

TR-9414 1/01-TN109TR 01-TN109 9414

TR-10414 1/01-TN110TR 01-TN110 10414

TR-11414 1/01-TN111TR 01-TN111 11414

TR-12018 1/01-TN112TR 01-TN112 12018

TR-14003 1/01-TN114TR 01-TN114 14003

TR-B12A 1/09-TN101TR 09-TN100 B12A

TR-B611 1/01-TN100TR-D 01-TN100 B611

TR-B818A 2/01-TN100TR-C 01-TN100 B818A

TR-G011 N/A ACC-TN100 G011

TR-G433 N/A ACC-TN100 G433

TR-G-1-1 2/G-TN101 G-TN101 1674

TR-R200A 2/15-TN102 15-TN102 R200A

G ra p h ic S ca le

/1 6"

0"

G ra p h ic S ca le

/1 6"

0"

G ra p h ic S ca le

/8

0"

G ra p h ic S ca le

/3 2"

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

/8

0"

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

G ra p h ic S ca le

/2

0"

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

A/E:Consultant:

Sprinklered

OMAHA EHRM INFRASTRUCTURE

UPGRADE DESIGN

636-21-704

B

IM

/V

IS

N

O m a h a

E H

R M

/6

-7

.B

.T R

.r v t

/1

/2

:1

:3

A

M

TECHNOLOGY COVERSHEET

PDN DJJ

ISSUED FOR BID

FULLY SPRINKLERED

636 - OMAHA VA MEDICAL CENTER

MAY 15, 2023

Office of Construction and

Facilities Management 00-TN000

2882 106TH STREET

DES MOINES, IA 50322

515.334.9906 FAX: 515.334.9908

www.imegcorp.com # 21005326.00

Revisions: Date:

1. THE EXISTING MAIN COMPUTER ROOM (MCR) AND TELECOM ROOMS (TR) TO REMAIN

OPERATIONAL DURING THE INSTALLATION OF THE NEW STRUCTURED CABLING AND

BACKBONE CABLING SYSTEMS. THE EXISTING SYSTEMS SHALL NOT BE DISRUPTED UNLESS

COORDINATED IN ADVANCE WITH OIT AND AT THEIR DISCRETION ON DATE AND TIME.

2. COORDINATE EACH TR CUTOVER WITH OIT AT THEIR DISCRETION ON DATE AND TIME.

PHASE 1 - PATHWAYS AND INFRASTRUCTURE

1. INSTALL NEW INTER-BUILDING UNDERGROUND DUCT BANK CONDUITS.

2. BUILD OUT NEW MCR LAYOUT.

A. COORDINATE BUILDOUT WITH OIT FOR EXISTING FIBER OPTIC INFRASTRUCTURE TO

EXISTING TR AND EXISTING MCR EQUIPMENT TO REMAIN FUNCTIONAL .

3. BUILD OUT NEW TR SPACES.

4. INSTALL NEW INTRA-BUILDING BACKBONE CABLING PATHWAYS.

PHASE 2 - BACKBONE CABLING

1. INSTALL INTER-BUILDING BACKBONE CABLING.

2. INSTALL INTRA-BUILDING BACKBONE CABLING.

3. TERMINATE AND TEST.

PHASE 3 - HORIZONTAL CABLING

1. INSTALL NEW CAT 6A CABLING.

A. TERMINATE CABLING IN NEW TR PATCH PANELS.

B. NEATLY COIL CABLING AT EXISTING OR EXPANDED TR LOCATIONS FOR CUTOVER TO

NEW RACKS AND PATCH PANELS.

C. NEATLY COIL CABLING AT EXISTING OUTLET LOCATIONS.

PHASE 4 - CUTOVER

1. OIT INSTALLATION OF NETWORK SWITCHES AT EACH TR PLANNED FOR CUTOVER

2. REMOVE EXISTING OUTLET CABLING FROM OUTLET AND ROUTE NEW CAT 6A CABLING INTO

OUTLET.

A. NEATLY COIL EXISTING CABLING ABOVE CEILING.

3. REMOVE EXISTING EQUIPMENT RACKS AND INSTALL NEW EQUIPMENT RACKS EQUIPMENT IN

REMODELED OR EXPANDED TR.

4. TERMINATE AND TEST NEW CABLING.

5. OIT CUTOVER AND PATCHING TO NETWORK SWITCHES.

PHASE 5 - DEMOLITION

1. REMOVE OLD FIBER OPTIC BACKBONE CABLING FROM EACH OLD TR FOLLOWING

SUCCESSFUL CUTOVER TO NEW TR.

A. OTHER EXISTING SYSTEMS IN OLD TR TO REMAIN FUNCTIONAL.

2. REMOVE OLD HORIZONTAL CABLING FROM EACH OUTLET BACK TO ITS SOURCE FOLLOWING

SUCCESSFUL CUTOVER.

3. REMOVE ALL EQUIPMENT RACKS AND ASSOCIATED EQUIPMENT FROM EACH OLD TR

FOLLOWING SUCCESSFUL CUTOVER. COORDINATE WITH OIT PRIOR TO REMOVING EXISTING

EQUIPMENT RACKS FROM OLD TR AS ACTIVE CABLING AND EQUIPMENT MAY REMAIN.

TECHNOLOGY PHASING NOTES

1. THE LOCATION OF THE CONDUIT, HAND HOLES AND/OR MAINTENANCE HOLES SHOWN ARE

APPROXIMATE LOCATIONS. FIELD VERIFY THE LOCATION OF ALL UTILITIES PRIVATE AND/OR

PUBLIC PRIOR TO THE INSTALLATION OF THE COMPONENT. FIELD COORDINATE THE FINAL

LOCATION WITH THE OWNER AND ENGINEER PRIOR TO INSTALLATION.

2. POTHOLING TO LOCATE EXISTING UNDERGROUND UTILITIES, IF APPLICABLE, SHALL BE

INCLUDED IN THE CONTRACTOR'S BID. CONTRACTOR IS RESPONSIBLE FOR FINAL

PLACEMENT OF HAND HOLES AND/OR MAINTENANCE HOLES AND SHALL NOTIFY THE

ENGINEER OF FINAL LOCATIONS PRIOR TO INSTALLATION.

3. HAND HOLES AND/OR MAINTENANCE HOLES SHALL BE CONSTRUCTED SO THAT THE TOP OF

THE FRAME WILL BE FLUSH WITH THE GROUND LINE.

4. REMOVAL AND REPLACEMENT OF THE EXISTING UNDERGROUND UTILITIES THAT ARE

REQUIRED TO COMPLETE THE INSTALLATION SHALL BE INCLUDED IN THE CONTRACTOR'S

BID.

5. CONTRACTOR SHALL INCLUDE IN THEIR BID ANY REMOVAL AND REPLACEMENT OF EXISTING

SIDEWALK, PAVEMENT, GRASS, SHRUBS, TREES, ETC. THAT WILL BE IMPACTED BY THE

INSTALLATION OF THE NEW CONDUITS SHOWN ON THE DRAWINGS. IF TREES ARE REQUIRED

TO BE REMOVED THE CONTRACTOR SHALL CONTACT THE OWNER AND DISCUSS OPTIONS

PRIOR TO CUTTING DOWN ANY TREE OR SHRUB OVER 5' IN HEIGHT.

6. NO ADDITIONAL COST SHALL BE APPROVED FOR PLACING CONDUITS DEEPER THAN

REQUIRED MINIMUM DEPTH TO AVOID EXISTING UNDERGROUND UTILITIES.

7. PROVIDE A MINIMUM OF 25'-0" SLACK LOOP WITHIN EACH HAND HOLES AND/OR

MAINTENANCE HOLES. SLACK LOOP SHALL BE SECURE SO COPPER AND FIBER IS NOT

RESTING ON EARTH AFTER FINAL INSTALLATION.

TECHNOLOGY OUTSIDE PLANT NOTES

1. THE DRAWINGS INDICATE EXISTING ITEMS TO BE REMOVED. THE DRAWINGS ARE

INTENDED TO INDICATE THE SCOPE OF WORK REQUIRED AND DO NOT INDICATE EVERY

BOX, CONDUIT, OR WIRE THAT MUST BE REMOVED. THE CONTRACTOR SHALL VISIT THE

SITE PRIOR TO SUBMITTING A BID AND VERIFY EXISTING CONDITIONS.

2. ITEMS (i.e. EQUIPMENT RACKS, SWITCHES, ETC.) REMOVED AND NOT RELOCATED

REMAIN THE PROPERTY OF THE OWNER. THE CONTRACTOR SHALL BE RESPONSIBLE

FOR THE DISPOSAL OF MATERIAL THE OWNER DOES NOT WANT TO REUSE OR RETAIN.

(i.e., FOR MAINTENANCE PURPOSES).

3. EXISTING TO REMAIN DEVICES WITHIN OR ADJACENT TO THE PATH OF CONSTRUCTION

SHALL BE PROTECTED IN PLACE. DEVICES THAT MUST BE REMOVED SHALL BE TESTED

PRIOR TO REMOVAL, PROTECTED FROM DAMAGE, AND RE-INSTALLED IN ITS ORIGINAL

LOCATION DURING THE NEW CONSTRUCTION PHASE OF THE PROJECT.

4. OBTAIN APPROVAL FROM THE OWNER BEFORE TURNING OFF THE POWER TO

EQUIPMENT, SYSTEMS, PANELS, ETC. COORDINATE ALL OUTAGES WITH OWNER.

CONDUIT CONCEALED IN WALL CONSTRUCTION MAY BE ABANDONED IN PLACE IF NOT

AFFECTED BY OTHER CONSTRUCTION.

5. ALL CONDUIT SHALL BE REMOVED WHERE WALLS ARE BEING REMOVED. WHERE

CONDUIT IS IN THE CONCRETE SLAB, CUT OFF FLUSH, PULL OUT WIRE, AND PLUG.

WHERE CONDUIT IS RUN EXPOSED, ALL ASSOCIATED CLAMPS, SUPPORTS, HANGERS,

ETC., SHALL ALSO BE REMOVED.

6. COORDINATE ALL WORK WITH OTHER CONTRACTORS AT THE JOB SITE BEFORE

REMOVING EXISTING EQUIPMENT AND INSTALLING NEW ITEMS.

7. EXISTING CONDUIT IN GOOD CONDITION, MAY BE REUSED IN PLACE. RELOCATING

EXISTING CONDUIT SHALL NOT BE ALLOWED. BONDING CONDUCTORS SHALL BE

INSTALLED IN ALL REUSED CONDUIT TO ASSURE PROPER GROUND PATH.

8. EQUIPMENT REMOVAL IN CERTAIN LOCATIONS MAY REQUIRE THE INSTALLATION OF A

JUNCTION BOX TO RECONNECT CIRCUITS THAT REMAIN IN OPERATION. EXTEND

CONDUIT AND WIRING AS REQUIRED TO MAINTAIN POWER TO REMAINING EQUIPMENT.

9. DEVICES TO BE REMOVED SHALL HAVE ALL CONNECTED WIRING REMOVED TO THE

SOURCE.

10. DEVICES NOT TO BE REMOVED SHALL BE PROTECTED FROM THE ENVIRONMENT, AND

ALL ASSOCIATED CABLE/RACEWAYS ARE TO REMAIN AND BE PROTECTED. T.C. SHALL BE

RESPONSIBLE FOR REPAIR OF ANY INTERRUPTIONS TO PROTECTED DEVICES.

TECHNOLOGY DEMOLITION NOTES

1. SCOPE OF WORK INCLUDES RE-USE OF EXISTING TELECOMMUNICATIONS OUTLET ROUGH-

IN FOR NEW CATEGORY 6A CABLING. NEW CATEGORY 6A CABLING AT EXISTING OUTLET

LOCATIONS SHALL BE AS FOLLOWS:

• EXISTING 3/4” CONDUIT ROUGH-IN LOCATIONS TO RECEIVE A MAXIMUM OF TWO (2) CAT

6A CABLES.

• EXISTING 1” CONDUIT ROUGH-IN LOCATIONS TO RECEIVE A MAXIMUM OF FOUR (4) CAT

6A CABLES.

• PROVIDE NEW CONDUIT AND BACKBOX AT LOCATIONS EXCEEDING THE REQUIREMENTS

LISTED ABOVE. NEW CONDUIT SIZE SHALL BE BASED ON 40% FILL, TAKING INTO

CONSIDERATION THE DERATING OF THE CONDUIT CAPACITY FOR EACH 90 DEGREE

BEND.

2. FOR EXISTING ROUGH-IN WITH SHALLOW BACK BOXES: PROVIDE A SURFACE MOUNT

BACKBOX INSTALLED OVER TOP OF EXISTING IN-WALL BACKBOX (LEVITON 42777 OR SIM),

WITH AN ANGLED FACEPLATE (LEVITON 42081 SERIES OR SIM) TO ALLOW FOR BEND RADIUS

OF NEW CAT 6A CABLING.

3. NEW OUTLET LOCATIONS REQUIRING NEW IN-WALL OR SURFACE MOUNT ROUGH-IN ARE

NOTED ON THE DRAWINGS. ALL OTHER OUTLETS ARE ASSUMED TO UTILIZE EXISTING

ROUGH-IN.

4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADDITIONAL CONDUIT SLEEVES

AS REQUIRED FOR NEW CABLING PATHWAYS.

5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CABLE LOCATIONS WITHIN FURNITURE

AND WILL BE RESPONSIBLE FOR ALL FURNITURE MOVES TO COMPLETE THE INSTALLATION

OF CABLING IN OUTLETS.

6. CONCEAL ALL CONDUIT IN WALLS, PARTITIONS, ABOVE CEILING, IN FLOOR SLAB, ETC.

UNLESS OTHERWISE INDICATED ON THE PLANS OR IN THE SPECIFICATIONS. CONDUIT IN

MECHANICAL ROOMS AND STORAGE ROOMS WITHOUT CEILINGS MAY BE EXPOSED ON

BUILDING STRUCTURE.

7. BOXES LOCATED ON OPPOSITE SIDES OF NON-RATED WALLS SHALL BE OFFSET A MINIMUM

OF 6" HORIZONTALLY. BOXES ON OPPOSITE SIDES OF FIRE RATED WALLS SHALL BE

OFFSET A MINIMUM OF 24" HORIZONTALLY. "THRU-THE-WALL" BOXES SHALL NOT BE

ALLOWED WITHOUT PRIOR WRITTEN APPROVAL OF THE ARCHITECT/ENGINEER.

8. VERIFY ALL FURNITURE, MODULAR FURNITURE, AND EQUIPMENT LOCATIONS WITH

ARCHITECTURAL PLANS, ELEVATIONS, AND REVIEWED SHOP DRAWINGS. PRIOR TO MAKING

THE ACTUAL TELECOMMUNICATIONS INSTALLATION, ADJUST OUTLETS OR CONNECTION

LOCATIONS TO ACCOMMODATE FURNITURE AND/OR EQUIPMENT.

9. TELECOMMUNICATIONS EQUIPMENT SHALL BE MOUNTED TO ALLOW ACCESS TO

ELECTRICAL AND MECHANICAL EQUIPMENT. ALL MOUNTING OF TELECOMMUNICATION

DEVICES ON EQUIPMENT SUPPLIED BY ANOTHER CONTRACTOR SHALL BE APPROVED IN

ADVANCE BY THE OTHER CONTRACTOR.

10. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL OPENINGS REQUIRED IN WALLS. ALL

OPENINGS SHALL BE REPAIRED TO MATCH EXISTING BY A QUALIFIED CONTRACTOR AT THE

EXPENSE OF THIS CONTRACTOR. ALL CONDUITS THROUGH WALLS SHALL BE GROUTED OR

SEALED INTO OPENINGS.

11. ALL MATERIALS USED TO SEAL PENETRATIONS OF FIRE RATED WALLS AND FLOORS SHALL

BE TESTED AND CERTIFIED AS A SYSTEM PER ASTM E814 STANDARDS FOR FIRE TESTS OF

THROUGH-PENETRATION FIRESTOPS. REFER TO DIVISION 7 FOR ADDITIONAL INFORMATION

AND REQUIREMENTS SPECIFIC TO FIRESTOPPING.

12. THE TECHNOLOGY CONTRACTOR IS RESPONSIBLE FOR REMOVAL AND REPLACEMENT OF

THE CEILINGS, CEILING TILES, AND CEILING GRID ASSOCIATED WITH THE AREAS OF WORK

BY ALL CONTRACTORS.

13. ALL CABLE TRAY SIZES ARE AS DEFINED ON THE DRAWINGS. REFER TO SPECIFICATION

SECTION 27 05 36 FOR INSTALLATION REQUIREMENTS.

14. FLUSH MOUNT ALL NEW TELECOMMUNICATION OUTLETS AT +18" FROM FLOOR

(CENTERLINE DIMENSION), EXCEPT WHERE OTHERWISE NOTED. OUTLETS MAY BE SURFACE

MOUNTED WHEN CONDUIT IS SPECIFIED EXPOSED.

15. EACH CONTRACTOR IS RESPONSIBLE FOR DAMAGE CAUSED BY THEIR ACTIONS TO THE

WALLS, FLOORS, CEILINGS, AND ROOFS. THE CONTRACTOR WHOSE WORK CAUSES

DAMAGE IS RESPONSIBLE FOR PATCHING TO MATCH ORIGINAL CONSTRUCTION, FIRE

RATING, AND FINISH.

TECHNOLOGY INSTALLATION NOTES:

G ra p h ic S ca le

/1 6"

0"

G ra p h ic S ca le

/1 6"

0"

G ra p h ic S ca le

/8

0"

G ra p h ic S ca le

/3 2"

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

/8

0"

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

G ra p h ic S ca le

/2

0"

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

A/E:Consultant:

Sprinklered

OMAHA EHRM INFRASTRUCTURE

UPGRADE DESIGN

636-21-704

B

IM

/V

IS

N

O m a h a

E H

R M

/6

-7

.B

.T R

.r v t

/1

/2

:1

:3

A

M

TECHNOLOGY NOTES AND SHEET INDEX

PDN DJJ

ISSUED FOR BID

FULLY SPRINKLERED

636 - OMAHA VA MEDICAL CENTER

MAY 15, 2023

Office of Construction and

Facilities Management 00-TN001

2882 106TH STREET

DES MOINES, IA 50322

515.334.9906 FAX: 515.334.9908

www.imegcorp.com # 21005326.00

TECHNOLOGY SHEET INDEX

01-TN107D BLDG. 01 - LEVEL 07 FLOOR PLAN - TECHNOLOGY - QUADRANT D

01-TN107E BLDG. 01 - LEVEL 07 FLOOR PLAN - TECHNOLOGY - QUADRANT E

01-TN107TR BLDG. 01 - LEVEL 07 - TECHNOLOGY ROOM ENLARGEMENTS

01-TN108 BLDG. 01 - LEVEL 08 FLOOR PLAN - TECHNOLOGY - OVERALL

01-TN108B BLDG. 01 - LEVEL 08 FLOOR PLAN - TECHNOLOGY - QUADRANT B

01-TN108C BLDG. 01 - LEVEL 08 FLOOR PLAN - TECHNOLOGY - QUADRANT C

01-TN108D BLDG. 01 - LEVEL 08 FLOOR PLAN - TECHNOLOGY - QUADRANT D

01-TN108E BLDG. 01 - LEVEL 08 FLOOR PLAN - TECHNOLOGY - QUADRANT E

01-TN108TR BLDG. 01 - LEVEL 08 - TECHNOLOGY ROOM ENLARGEMENTS

01-TN109 BLDG. 01 - LEVEL 09 FLOOR PLAN - TECHNOLOGY - OVERALL

01-TN109B BLDG. 01 - LEVEL 09 FLOOR PLAN - TECHNOLOGY - QUADRANT B

01-TN109C BLDG. 01 - LEVEL 09 FLOOR PLAN - TECHNOLOGY - QUADRANT C

01-TN109D BLDG. 01 - LEVEL 09 FLOOR PLAN - TECHNOLOGY - QUADRANT D

01-TN109E BLDG. 01 - LEVEL 09 FLOOR PLAN - TECHNOLOGY - QUADRANT E

01-TN109TR BLDG. 01 - LEVEL 09 - TECHNOLOGY ROOM ENLARGEMENTS

01-TN110 BLDG. 01 - LEVEL 10 FLOOR PLAN - TECHNOLOGY - OVERALL

01-TN110B BLDG. 01 - LEVEL 10 FLOOR PLAN - TECHNOLOGY - QUADRANT B

01-TN110C BLDG. 01 - LEVEL 10 FLOOR PLAN - TECHNOLOGY - QUADRANT C

01-TN110D BLDG. 01 - LEVEL 10 FLOOR PLAN - TECHNOLOGY - QUADRANT D

01-TN110E BLDG. 01 - LEVEL 10 FLOOR PLAN - TECHNOLOGY - QUADRANT E

01-TN110TR BLDG. 01 - LEVEL 10 - TECHNOLOGY ROOM ENLARGEMENTS

01-TN111 BLDG. 01 - LEVEL 11 FLOOR PLAN - TECHNOLOGY - OVERALL

01-TN111B BLDG. 01 - LEVEL 11 FLOOR PLAN - TECHNOLOGY - QUADRANT B

01-TN111C BLDG. 01 - LEVEL 11 FLOOR PLAN - TECHNOLOGY - QUADRANT C

01-TN111D BLDG. 01 - LEVEL 11 FLOOR PLAN - TECHNOLOGY - QUADRANT D

01-TN111E BLDG. 01 - LEVEL 11 FLOOR PLAN - TECHNOLOGY - QUADRANT E

01-TN111TR BLDG. 01 - LEVEL 11 - TECHNOLOGY ROOM ENLARGEMENTS

01-TN112 BLDG. 01 - LEVEL 12 FLOOR PLAN - TECHNOLOGY - OVERALL

01-TN112B BLDG. 01 - LEVEL 12 FLOOR PLAN - TECHNOLOGY - QUADRANT B

01-TN112E BLDG. 01 - LEVEL 12 FLOOR PLAN - TECHNOLOGY - QUADRANT E

01-TN112TR BLDG. 01 - LEVEL 12 - TECHNOLOGY ROOM ENLARGEMENTS

01-TN113 BLDG. 01 - LEVEL 13 FLOOR PLAN - TECHNOLOGY - OVERALL

01-TN113E BLDG. 01 - LEVEL 13 FLOOR PLAN - TECHNOLOGY - QUADRANT E

01-TN114 BLDG. 01 - LEVEL 14 FLOOR PLAN - TECHNOLOGY - OVERALL

01-TN114E BLDG. 01 - LEVEL 14 FLOOR PLAN - TECHNOLOGY - QUADRANT E

01-TN114TR BLDG. 01 - LEVEL 14 - TECHNOLOGY ROOM ENLARGEMENTS

02-TN200 BLDG. 02- LEVEL 00 FLOOR PLAN - TECHNOLOGY

02-TN201 BLDG. 02- LEVEL 01 FLOOR PLAN - TECHNOLOGY

02-TN202 BLDG. 02- LEVEL 02 FLOOR PLAN - TECHNOLOGY

06-TD101 BLDG. 06 - LEVEL 01 FLOOR DEMOLITION PLAN - TECHNOLOGY

06-TN101 BLDG. 06 - LEVEL 01 FLOOR PLAN - TECHNOLOGY

06-TN101TR BLDG. 06 - LEVEL 01 - TECHNOLOGY ROOM ENLARGEMENTS

08-TN201 BLDG. 08 - LEVEL 01 FLOOR PLAN - TECHNOLOGY

09-TD100 BLDG. 09 - LEVEL 00 FLOOR DEMOLITION PLAN - TECHNOLOGY

09-TD101 BLDG. 09 - LEVEL 01 FLOOR DEMOLITION PLAN - TECHNOLOGY

09-TN100 BLDG. 09 - LEVEL 00 FLOOR PLAN - TECHNOLOGY

09-TN101 BLDG. 09 - LEVEL 01 FLOOR PLAN - TECHNOLOGY

09-TN101TR BLDG. 09 - LEVEL 00 - TECHNOLOGY ROOM ENLARGEMENTS

15-TD100 BLDG. 15 - LEVEL 00 FLOOR DEMOLITION PLAN - TECHNOLOGY

15-TD101 BLDG. 15 - LEVEL 01 FLOOR DEMOLITION PLAN - TECHNOLOGY

15-TD102 BLDG. 15 - LEVEL 02 FLOOR DEMOLITION PLAN - TECHNOLOGY

15-TD103 BLDG. 15 - LEVEL 03 FLOOR DEMOLITION PLAN - TECHNOLOGY

15-TN100 BLDG. 15 - LEVEL 00 FLOOR PLAN - TECHNOLOGY

15-TN101 BLDG. 15 - LEVEL 01 FLOOR PLAN - TECHNOLOGY

15-TN102 BLDG. 15 - LEVEL 02 FLOOR PLAN - TECHNOLOGY

15-TN103 BLDG. 15 - LEVEL 03 FLOOR PLAN - TECHNOLOGY

ACC-TN100 BLDG. ACC - LEVEL 00 - TECHNOLOGY

ACC-TN101 BLDG. ACC - LEVEL 01 - TECHNOLOGY

ACC-TN102 BLDG. ACC - LEVEL 02 - TECHNOLOGY

D-TN101 BLDG. D - LEVEL 01 FLOOR PLANS - TECHNOLOGY

G-TN101 GEN. BLDG. - LEVEL 01 FLOOR PLANS - TECHNOLOGY

TN400 TECHNOLOGY DETAILS

TN401 TECHNOLOGY DETAILS

TN402 TECHNOLOGY DETAILS

TN500 TECHNOLOGY DIAGRAMS

TN501 TECHNOLOGY DIAGRAMS

TN502 TECHNOLOGY DIAGRAMS

TN503 TECHNOLOGY DIAGRAMS

TN504 TECHNOLOGY DIAGRAMS

TN505 TECHNOLOGY DIAGRAMS

TN506 TECHNOLOGY DIAGRAMS

TN507 TECHNOLOGY DIAGRAMS

TN508 TECHNOLOGY DIAGRAMS

TN600 TECHNOLOGY SCHEDULES

TECHNOLOGY SHEET INDEX

00-TN000 TECHNOLOGY COVERSHEET

00-TN001 TECHNOLOGY NOTES AND SHEET INDEX

00-TN002 SITE PLAN - TECHNOLOGY

01-TD100 BLDG. 01 - LEVEL 00 FLOOR DEMOLITION PLAN - TECHNOLOGY - OVERALL

01-TD100A BLDG. 01 - LEVEL 00 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT A

01-TD100B BLDG. 01 - LEVEL 00 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT B

01-TD100C BLDG. 01 - LEVEL 00 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT C

01-TD100D BLDG. 01 - LEVEL 00 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT D

01-TD100E BLDG. 01 - LEVEL 00 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT E

01-TD101 BLDG. 01 - LEVEL 01 FLOOR DEMOLITION PLAN - TECHNOLOGY - OVERALL

01-TD101A BLDG. 01 - LEVEL 01 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT A

01-TD101B BLDG. 01 - LEVEL 01 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT B

01-TD101C BLDG. 01 - LEVEL 01 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT C

01-TD101D BLDG. 01 - LEVEL 01 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT D

01-TD101E BLDG. 01 - LEVEL 01 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT E

01-TD102 BLDG. 01 - LEVEL 02 FLOOR DEMOLITION PLAN - TECHNOLOGY - OVERALL

01-TD102B BLDG. 01 - LEVEL 02 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT B

01-TD102C BLDG. 01 - LEVEL 02 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT C

01-TD102D BLDG. 01 - LEVEL 02 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT D

01-TD102E BLDG. 01 - LEVEL 02 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT E

01-TD103 BLDG. 01 - LEVEL 03 FLOOR DEMOLITION PLAN - TECHNOLOGY - OVERALL

01-TD103B BLDG. 01 - LEVEL 03 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT B

01-TD103C BLDG. 01 - LEVEL 03 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT C

01-TD103D BLDG. 01 - LEVEL 03 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT D

01-TD103E BLDG. 01 - LEVEL 03 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT E

01-TD104 BLDG. 01 - LEVEL 04 FLOOR DEMOLITION PLAN - TECHNOLOGY - OVERALL

01-TD104B BLDG. 01 - LEVEL 04 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT B

01-TD104C BLDG. 01 - LEVEL 04 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT C

01-TD104D BLDG. 01 - LEVEL 04 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT D

01-TD104E BLDG. 01 - LEVEL 04 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT E

01-TD105 BLDG. 01 - LEVEL 05 FLOOR DEMOLITION PLAN - TECHNOLOGY - OVERALL

01-TD105B BLDG. 01 - LEVEL 05 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT B

01-TD105C BLDG. 01 - LEVEL 05 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT C

01-TD105D BLDG. 01 - LEVEL 05 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT D

01-TD105E BLDG. 01 - LEVEL 05 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT E

01-TD106 BLDG. 01 - LEVEL 06 FLOOR DEMOLITION PLAN - TECHNOLOGY - OVERALL

01-TD106B BLDG. 01 - LEVEL 06 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT B

01-TD106C BLDG. 01 - LEVEL 06 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT C

01-TD106D BLDG. 01 - LEVEL 06 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT D

01-TD106E BLDG. 01 - LEVEL 06 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT E

01-TD107 BLDG. 01 - LEVEL 07 FLOOR DEMOLITION PLAN - TECHNOLOGY - OVERALL

01-TD107B BLDG. 01 - LEVEL 07 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT B

01-TD107C BLDG. 01 - LEVEL 07 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT C

01-TD107D BLDG. 01 - LEVEL 07 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT D

01-TD107E BLDG. 01 - LEVEL 07 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT E

01-TD108 BLDG. 01 - LEVEL 08 FLOOR DEMOLITION PLAN - TECHNOLOGY - OVERALL

01-TD108B BLDG. 01 - LEVEL 08 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT B

01-TD108C BLDG. 01 - LEVEL 08 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT C

01-TD108D BLDG. 01 - LEVEL 08 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT D

01-TD108E BLDG. 01 - LEVEL 08 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT E

01-TD109 BLDG. 01 - LEVEL 09 FLOOR DEMOLITION PLAN - TECHNOLOGY - OVERALL

01-TD109B BLDG. 01 - LEVEL 09 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT B

01-TD109C BLDG. 01 - LEVEL 09 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT C

01-TD109D BLDG. 01 - LEVEL 09 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT D

01-TD109E BLDG. 01 - LEVEL 09 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT E

01-TD110 BLDG. 01 - LEVEL 10 FLOOR DEMOLITION PLAN - TECHNOLOGY - OVERALL

01-TD110B BLDG. 01 - LEVEL 10 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT B

01-TD110C BLDG. 01 - LEVEL 10 FLOOR DEMOLITION PLAN- TECHNOLOGY - QUADRANT C

01-TD110D BLDG. 01 - LEVEL 10 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT D

01-TD110E BLDG. 01 - LEVEL 10 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT E

01-TD111 BLDG. 01 - LEVEL 11 FLOOR DEMOLITION PLAN - TECHNOLOGY - OVERALL

01-TD111B BLDG. 01 - LEVEL 11 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT B

01-TD111C BLDG. 01 - LEVEL 11 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT C

01-TD111D BLDG. 01 - LEVEL 11 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT D

01-TD111E BLDG. 01 - LEVEL 11 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT E

01-TD112 BLDG. 01 - LEVEL 12 FLOOR DEMOLITION PLAN - TECHNOLOGY - OVERALL

01-TD112B BLDG. 01 - LEVEL 12 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT B

01-TD112D BLDG. 01 - LEVEL 12 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT D

01-TD112E BLDG. 01 - LEVEL 12 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT E

01-TD113 BLDG. 01 - LEVEL 13 FLOOR DEMOLITION PLAN - TECHNOLOGY - OVERALL

01-TD113B BLDG. 01 - LEVEL 13 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT B

01-TD113E BLDG. 01 - LEVEL 13 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT E

01-TD114 BLDG. 01 - LEVEL 14 FLOOR DEMOLITION PLAN - TECHNOLOGY - OVERALL

01-TD114E BLDG. 01 - LEVEL 14 FLOOR DEMOLITION - TECHNOLOGY - QUADRANT E

01-TN100 BLDG. 01 - LEVEL 00 FLOOR PLAN - TECHNOLOGY - OVERALL

01-TN100A BLDG. 01 - LEVEL 00 FLOOR PLAN - TECHNOLOGY - QUADRANT A

01-TN100B BLDG. 01 - LEVEL 00 FLOOR PLAN - TECHNOLOGY - QUADRANT B

01-TN100C BLDG. 01 - LEVEL 00 FLOOR PLAN - TECHNOLOGY - QUADRANT C

01-TN100D BLDG. 01 - LEVEL 00 FLOOR PLAN - TECHNOLOGY - QUADRANT D

01-TN100E BLDG. 01 - LEVEL 00 FLOOR PLAN - TECHNOLOGY - QUADRANT E

01-TN100TR-A BLDG. 01 - LEVEL 00 - TECHNOLOGY ROOM ENLARGEMENTS

01-TN100TR-B BLDG. 01 - LEVEL 00 - TECHNOLOGY ROOM ENLARGEMENTS

01-TN100TR-C BLDG. 01 - LEVEL 00 - TECHNOLOGY ROOM ENLARGEMENTS

01-TN100TR-D BLDG. 01 - LEVEL 00 - TECHNOLOGY ROOM ENLARGEMENTS

01-TN101 BLDG. 01 - LEVEL 01 FLOOR PLAN - TECHNOLOGY - OVERALL

01-TN101A BLDG. 01 - LEVEL 01 FLOOR PLAN - TECHNOLOGY - QUADRANT A

01-TN101B BLDG. 01 - LEVEL 01 FLOOR PLAN - TECHNOLOGY - QUADRANT B

01-TN101C BLDG. 01 - LEVEL 01 FLOOR PLAN - TECHNOLOGY - QUADRANT C

01-TN101D BLDG. 01 - LEVEL 01 FLOOR PLAN - TECHNOLOGY - QUADRANT D

01-TN101E BLDG. 01 - LEVEL 01 FLOOR PLAN - TECHNOLOGY - QUADRANT E

01-TN101TR-A BLDG. 01 - LEVEL 01 - TECHNOLOGY ROOM ENLARGEMENTS

01-TN101TR-B BLDG. 01 - LEVEL 01 - TECHNOLOGY ROOM ENLARGEMENTS

01-TN102 BLDG. 01 - LEVEL 02 FLOOR PLAN - TECHNOLOGY - OVERALL

01-TN102B BLDG. 01 - LEVEL 02 FLOOR PLAN - TECHNOLOGY - QUADRANT B

01-TN102C BLDG. 01 - LEVEL 02 FLOOR PLAN - TECHNOLOGY - QUADRANT C

01-TN102D BLDG. 01 - LEVEL 02 FLOOR PLAN - TECHNOLOGY - QUADRANT D

01-TN102E BLDG. 01 - LEVEL 02 FLOOR PLAN - TECHNOLOGY - QUADRANT E

01-TN102TR BLDG. 01 - LEVEL 02 - TECHNOLOGY ROOM ENLARGEMENTS

01-TN103 BLDG. 01 - LEVEL 03 FLOOR PLAN - TECHNOLOGY - OVERALL

01-TN103B BLDG. 01 - LEVEL 03 FLOOR PLAN - TECHNOLOGY - QUADRANT B

01-TN103C BLDG. 01 - LEVEL 03 FLOOR PLAN - TECHNOLOGY - QUADRANT C

01-TN103D BLDG. 01 - LEVEL 03 FLOOR PLAN - TECHNOLOGY - QUADRANT D

01-TN103E BLDG. 01 - LEVEL 03 FLOOR PLAN - TECHNOLOGY - QUADRANT E

01-TN103TR BLDG. 01 - LEVEL 03 - TECHNOLOGY ROOM ENLARGEMENTS

01-TN104 BLDG. 01 - LEVEL 04 FLOOR PLAN - TECHNOLOGY - OVERALL

01-TN104B BLDG. 01 - LEVEL 04 FLOOR PLAN - TECHNOLOGY - QUADRANT B

01-TN104C BLDG. 01 - LEVEL 04 FLOOR PLAN - TECHNOLOGY - QUADRANT C

01-TN104D BLDG. 01 - LEVEL 04 FLOOR PLAN - TECHNOLOGY - QUADRANT D

01-TN104E BLDG. 01 - LEVEL 04 FLOOR PLAN - TECHNOLOGY - QUADRANT E

01-TN104TR BLDG. 01 - LEVEL 04 - TECHNOLOGY ROOM ENLARGEMENTS

01-TN105 BLDG. 01 - LEVEL 05 FLOOR PLAN - TECHNOLOGY - OVERALL

01-TN105B BLDG. 01 - LEVEL 05 FLOOR PLAN - TECHNOLOGY - QUADRANT B

01-TN105C BLDG. 01 - LEVEL 05 FLOOR PLAN - TECHNOLOGY - QUADRANT C

01-TN105D BLDG. 01 - LEVEL 05 FLOOR PLAN - TECHNOLOGY - QUADRANT D

01-TN105E BLDG. 01 - LEVEL 05 FLOOR PLAN - TECHNOLOGY - QUADRANT E

01-TN105TR BLDG. 01 - LEVEL 05 - TECHNOLOGY ROOM ENLARGEMENTS

01-TN106 BLDG. 01 - LEVEL 06 FLOOR PLAN - TECHNOLOGY - OVERALL

01-TN106B BLDG. 01 - LEVEL 06 FLOOR PLAN - TECHNOLOGY - QUADRANT B

01-TN106C BLDG. 01 - LEVEL 06 FLOOR PLAN - TECHNOLOGY - QUADRANT C

01-TN106D BLDG. 01 - LEVEL 06 FLOOR PLAN - TECHNOLOGY - QUADRANT D

01-TN106E BLDG. 01 - LEVEL 06 FLOOR PLAN - TECHNOLOGY - QUADRANT E

01-TN106TR BLDG. 01 - LEVEL 06 - TECHNOLOGY ROOM ENLARGEMENTS

01-TN107 BLDG. 01 - LEVEL 07 FLOOR PLAN - TECHNOLOGY - OVERALL

01-TN107B BLDG. 01 - LEVEL 07 FLOOR PLAN - TECHNOLOGY - QUADRANT B

01-TN107C BLDG. 01 - LEVEL 07 FLOOR PLAN - TECHNOLOGY - QUADRANT C

D

D

D

D

D

D

D

D

D D

ONE

WAY

G

5'

5'

5'

5'

5'

4.9986

"LEG A"

(2) 4" CONDUITS

"LEG B"

(2) 4" CONDUITS

"LEG A"

(8) 4" CONDUITS

"LEG A"

(8) 4" CONDUITS

"LEG A"

(6) 4" CONDUITS

"LEG A"

(2) 4" CONDUITS

"LEG A"

(2) 4" CONDUITS

1 "LEG A"

(2) 4" CONDUITS

"LEG A"

(4) 4" CONDUITS

"LEG B"

(2) 4" CONDUITS

"LEG B"

(2) 4" CONDUITS

1"LEG B"

(4) 4" CONDUITS

"LEG B"

(2) 4" CONDUITS

"LEG B"

(8) 4" CONDUITS

"LEG B"

(2) 4" CONDUITS

"LEG B"

(2) 4" CONDUITS

"LEG B"

(6) 4" CONDUITS

"LEG B"

(2) 4" CONDUITS

HANDHOLE

HANDHOLE

HANDHOLE

HANDHOLE

HANDHOLE

HANDHOLE

HANDHOLE

HANDHOLE

HANDHOLE

HANDHOLE

HANDHOLE

HANDHOLE

HANDHOLE

HANDHOLE

HANDHOLE

HANDHOLE

HANDHOLE

HANDHOLE

HANDHOLE

HANDHOLE

HANDHOLE

HANDHOLE

HANDHOLE

"LEG A"

(2) 4" CONDUITS

TUNNEL

ENTRANCE

BUILDING 1

ACC

BUILDING 6

BUILDING 8

BUILDING 9

BUILDING 2

BUILDING D

G ra p h ic S ca le

/1 6"

0"

G ra p h ic S ca le

/1 6"

0"

G ra p h ic S ca le

/8

0"

G ra p h ic S ca le

/3 2"

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

/8

0"

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

G ra p h ic S ca le

/2

0"

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

A/E:Consultant:

Sprinklered

OMAHA EHRM INFRASTRUCTURE

UPGRADE DESIGN

636-21-704

B

IM

/V

IS

N

O m a h a

E H

R M

/6

-7

.B

.T R

.r v t

/1

/2

:1

:3

A

M

SITE PLAN - TECHNOLOGY

PDN DJJ

ISSUED FOR BID

FULLY SPRINKLERED

OMAHA VA MEDICAL CENTER

MAY 15, 2023

Office of Construction and

Facilities Management 00-TN002

2882 106TH STREET

DES MOINES, IA 50322

515.334.9906 FAX: 515.334.9908

www.imegcorp.com # 21005326.00

1" = 60'-0"

SITE PLAN - TECHNOLOGY

KEYNOTES:

1. ALL UNDERGROUND CONDUITS SHALL BE

INSTALLED IN CONCRETE ENCASED DUCT

BANK. REFER TO CIVIL DRAWINGS FOR DUCT

BANK AND HAND HOLE DETAILS.

2. CONDUITS INSTALLED IN EXISTING TUNNEL.

INSTALL CONDUITS ON SOUTH WALL IN

GROUPS OF (2) FOR EACH BUILDING SERVED

WITH PULL BOX EVERY 100'. LABEL PULL

BOXES WITH BUILDING DESTINATION.

CONDUITS LEAVING EXISTING TUNNEL TO

UNDERGROUND PATHWAY SHALL BE

INSTALLED IN CONCRETE ENCASED DUCT

BANK.

SHEET NOTES:

1. THIS DRAWING IS SHOWN FOR INTENT OF

CONDUIT AND FIBER OPTIC CABLE ROUTING.

REFER TO CIVIL DRAWINGS FOR EXACT DUCT

BANK AND PATHWAY INFORMATION.

2. REFER TO TN402 FOR EXTERIOR PATHWAY

DETAILS.

3. PROVIDE (3) 3-CELL TEXTILE INNERDUCTS IN

EACH CONDUIT. REFER TO 2/TN402 FOR

ADDITIONAL INFORMATION.

B501

B502

B721

B818A

B723

OFFICE

SERVER RM

SERVER RM

B590

B577

B556B

B556

B556A B551A

B551 B545

B514

B542

B540

B537

B533AA

B533A

B533

B522

B504 B500

A101

#1

#2

BLDG. 19

B589 B024

B505 B505A

B503

B024A

B024AA

B024E

B024C

B024D B024F

B025

B009A

B009

B003

B005

B119 B119A

B111

B094

B090

B079

B070

B030

B036

B039

B040

B030A

B069A

B046B049B051

B064

B054

B069B

B069 B075

#3

#4

#5

B508 B506

B556D

B556C

B103

#7 #8

B514A

B535

B540A

B535A

B522A

B629B B629A

B629C B629D

B612 B610

B702

B617 B615 B613 B607 B605

B601

B632

B700

B630

B624

B714

B802

B710

B717

B712

B719 B804

B834 B836

B833 B835

B818

B816

B716

B726

B724

B821 B821A

B821B

B821D B821C

B808

B806

B813

B803

B805

B805A

B705

B805B

B703

B701

B830

B832

B609

B818B

B802A

B801

B614

B601A

B611

B702B

B629

B702

B702C

B626

B628

B837

B556E

B556F

B113

B001

B700A

B002

B020

B080B530

B579

B700B

B815

B728

B622

B007

B707B708

B095

B588A

B580 B581

B582

B582B

B582C

B583

B584

B584A

B585

B586

B587

B582A

B588

B807

B801

B702G B702F B702E B702D

B069C

B618

B833A

B618A

B805C

B632B

B632A

B618C

B618B

B005A

B102

B079A

B526

B526A

B524A

B524A

B503A

10 9

BLDG. 17

AIR CONDITIONING

LAB

COLD ROOM G.C. LAB

STORAGE

LAB

STORAGE

TLT

LOCKERS

RESEARCH

LAB

PLMONARY STORRESEARCH

LAB

OFFICE

BIOMED

BIO MED SHOP/OFFICE

STORAGE

LINEN CHUTE

PLUMBING

SHOP

EMS

EQUIPMENT

STORAGE

WELDING

SHOP

MECHANICAL

HVAC

ELECTRICAL

STORAGE

TELEPHONE

SWITCH

ROOM

OFFICE

PHARMACY STORAGE

STORAGE

WATER

METER

MORGUE

STOR

MORGUE

MECHTLT

COMPRESSED GAS

LINEN CHUTE

JAN

RECEIVING

AREA

OFFICE

WAREHOUSE

STORAGE

STORAGE

PLUMBING

STORAGE

PAINT

ELEVATOR

PIT

MENS TOILET

WOMENS TOILET

MECHANICAL

STORAGE

TRAINING ROOM

CARPENTER SHOP

STOR

OFFICE

EMS OFFICE

OFFICE

STORAGE

HVAC

ELECT

MECHANICAL

OFFICES OFFICE

OFFICE

OFFICE OFFICE

TELECOM

OFFICE D

ELECTRIC

JAN

LOCKER

CLOTHING

ROOM

LINEN

SUPPLY

PHARMACY

OFFICE

STOR

BREAK

IT

VAULT

OFFICE

ELEC

OFFICE

OFFICEOFFICE

OFFICE

OFFICE OFFICE OFFICE

OFFICEOFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICES

OFFICE

OFFICE

CANTEEN

STORAGE

OFFICES

STOR

STORAGE

OFFICE

OFFICE

A/C OPERATORS

EMS

STORAGE

OFFICE

MAIL RM/ COPY

CENTER

MECHANICAL

SPACE

STOR

STOR

BIO HAZZARD/ INFECT

WASTE

MENS

CANTEEN

STORAGELOCK

SHOPREFRESHMENT SHOP

PULMONARY

RESEARCH

OFFICE

STOR

BIOMED SHRED

ROOM

PULMONARY

RESEARCH

LAB

PULMONARY

RESEARCH

LAB

PULMONARY

RESEARCH

LAB

OFFICE

BREAK RM

OFFICE

POLICE SUITE

HOLDING

TRAINING RM

DISPATCH

LOCKERS

ARMORY

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE OFFICE

OFFICE/CUBICLES

STORAGE

RADIO

ACTIVE

MATERIALS

OFFICE

OFFICE

OFFICES

OFFICEOFFICE

OFFICE

VOLUNTEER

SERVICES

OFFICE

OFFICE

PIV

OFFICE

OFFICE

VOLUNTEER

ESCORT

RM

STORAGE

STORAGE

EMS SHOP

OFFICE

CONF RM

ELEVATOR

ELEVATOR

ELEVATOR

ELEVATOR

ELEVATOR

ELEVATOR ELEVATOR

ELEVATOR

ELEVATOR ELEVATOR

ELEVATOR

STAIR

STAIR

STAIR

OPC STAIR

STAIR

STAIR

STAIR

STAIR STAIR

STAIR

OFFICE

STOR

OFFICE

OFFICE

IV RMIV RMIV RM BREAK RM

JANITOR

OFFICE

OFFICE

O.R. CHARGING

STATION

EMS

ELECTRICAL

ANTEROOM

STOR

STOR

ELECTRICAL

SUPPLY RM

WOMENS

OFFICE

DECONTAMINATION

SCOPE

PROCESSING

SCOPE

SCOPEPROCESSING

ANTEROOM

OXIDE

NITROUS

STOR

STOR

ELEVATOR LOBBY

ELEVATOR LOBBY

ELEVATOR

LOBBY

AUTOVALET

UP

UP

UP

UP

UP

UP

UP

DN

UP

UP

UP

BLOCKED

DOOR

BLOCKED

DOOR

8' OVERHEAD DOOR

8' OVERHEAD DOOR 8' OVERHEAD DOOR 8' OVERHEAD DOOR

8' OVERHEAD DOOR8' OVERHEAD DOOR

O V E R H E A D

D O O R

4'8" OVERHEAD DOOR

B501

B502

B721

B818A

B723

OFFICE

SERVER RM

SERVER RM

B590

B577

B556B

B556

B556A B551A

B551 B545

B514

B542

B540

B537

B533AA

B533A

B533

B522

B504 B500

A101

#1

#2

BLDG. 19

B589 B024

B505 B505A

B503

B024A

B024AA

B024E

B024C

B024D B024F

B025

B009A

B009

B003

B005

B119 B119A

B111

B094

B090

B079

B070

B030

B036

B039

B040

B030A

B069A

B046B049B051

B064

B054

B069B

B069 B075

#3

#4

#5

B508 B506

B556D

B556C

B103

#7 #8

B514A

B535

B540A

B535A

B522A

B629B B629A

B629C B629D

B612 B610

B702

B617 B615 B613 B607 B605

B601

B632

B700

B630

B624

B714

B802

B710

B717

B712

B719 B804

B834 B836

B833 B835

B818

B816

B716

B726

B724

B821 B821A

B821B

B821D B821C

B808

B806

B813

B803

B805

B805A

B705

B805B

B703

B701

B830

B832

B609

B818B

B802A

B801

B614

B601A

B611

B702B

B629

B702

B702C

B626

B628

B837

B556E

B556F

B113

B001

B700A

B002

B020

B080B530

B579

B700B

B815

B728

B622

B007

B707B708

B095

B588A

B580 B581

B582

B582B

B582C

B583

B584

B584A

B585

B586

B587

B582A

B588

B807

B801

B702G B702F B702E B702D

B069C

B618

B833A

B618A

B805C

B632B

B632A

B618C

B618B

B005A

B102

B079A

B526

B526A

B524A

B524A

B503A

10 9

BLDG. 17

AIR CONDITIONING

LAB

COLD ROOM G.C. LAB

STORAGE

LAB

STORAGE

TLT

LOCKERS

RESEARCH

LAB

PLMONARY STORRESEARCH

LAB

OFFICE

BIOMED

BIO MED SHOP/OFFICE

STORAGE

LINEN CHUTE

PLUMBING

SHOP

EMS

EQUIPMENT

STORAGE

WELDING

SHOP

MECHANICAL

HVAC

ELECTRICAL

STORAGE

TELEPHONE

SWITCH

ROOM

OFFICE

PHARMACY STORAGE

STORAGE

WATER

METER

MORGUE

STOR

MORGUE

MECHTLT

COMPRESSED GAS

LINEN CHUTE

JAN

RECEIVING

AREA

OFFICE

WAREHOUSE

STORAGE

STORAGE

PLUMBING

STORAGE

PAINT

ELEVATOR

PIT

MENS TOILET

WOMENS TOILET

MECHANICAL

STORAGE

TRAINING ROOM

CARPENTER SHOP

STOR

OFFICE

EMS OFFICE

OFFICE

STORAGE

HVAC

ELECT

MECHANICAL

OFFICES OFFICE

OFFICE

OFFICE OFFICE

TELECOM

OFFICE D

ELECTRIC

JAN

LOCKER

CLOTHING

ROOM

LINEN

SUPPLY

PHARMACY

OFFICE

STOR

BREAK

IT

VAULT

OFFICE

ELEC

OFFICE

OFFICEOFFICE

OFFICE

OFFICE OFFICE OFFICE

OFFICEOFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICES

OFFICE

OFFICE

CANTEEN

STORAGE

OFFICES

STOR

STORAGE

OFFICE

OFFICE

A/C OPERATORS

EMS

STORAGE

OFFICE

MAIL RM/ COPY

CENTER

MECHANICAL

SPACE

STOR

STOR

BIO HAZZARD/ INFECT

WASTE

MENS

CANTEEN

STORAGELOCK

SHOPREFRESHMENT SHOP

PULMONARY

RESEARCH

OFFICE

STOR

BIOMED SHRED

ROOM

PULMONARY

RESEARCH

LAB

PULMONARY

RESEARCH

LAB

PULMONARY

RESEARCH

LAB

OFFICE

BREAK RM

OFFICE

POLICE SUITE

HOLDING

TRAINING RM

DISPATCH

LOCKERS

ARMORY

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE OFFICE

OFFICE/CUBICLES

STORAGE

RADIO

ACTIVE

MATERIALS

OFFICE

OFFICE

OFFICES

OFFICEOFFICE

OFFICE

VOLUNTEER

SERVICES

OFFICE

OFFICE

PIV

OFFICE

OFFICE

VOLUNTEER

ESCORT

RM

STORAGE

STORAGE

EMS SHOP

OFFICE

CONF RM

ELEVATOR

ELEVATOR

ELEVATOR

ELEVATOR

ELEVATOR

ELEVATOR ELEVATOR

ELEVATOR

ELEVATOR ELEVATOR

ELEVATOR

STAIR

STAIR

STAIR

OPC STAIR

STAIR

STAIR

STAIR

STAIR STAIR

STAIR

OFFICE

STOR

OFFICE

OFFICE

IV RMIV RMIV RM BREAK RM

JANITOR

OFFICE

OFFICE

O.R. CHARGING

STATION

EMS

ELECTRICAL

ANTEROOM

STOR

STOR

ELECTRICAL

SUPPLY RM

WOMENS

OFFICE

DECONTAMINATION

SCOPE

PROCESSING

SCOPE

SCOPEPROCESSING

ANTEROOM

OXIDE

NITROUS

STOR

STOR

ELEVATOR LOBBY

ELEVATOR LOBBY

ELEVATOR

LOBBY

AUTOVALET

UP

UP

UP

UP

UP

UP

UP

DN

UP

UP

UP

BLOCKED

DOOR

BLOCKED

DOOR

8' OVERHEAD DOOR

8' OVERHEAD DOOR 8' OVERHEAD DOOR 8' OVERHEAD DOOR

8' OVERHEAD DOOR8' OVERHEAD DOOR

O V E R H E A D

D O O R

4'8" OVERHEAD DOOR

B501

B502

B721

B818A

B723

OFFICE

SERVER RM

SERVER RM

B590

B577

B556B

B556

B556A B551A

B551 B545

B514

B542

B540

B537

B533AA

B533A

B533

B522

B504 B500

A101

#1

#2

BLDG. 19

B589 B024

B505 B505A

B503

B024A

B024AA

B024E

B024C

B024D B024F

B025

B009A

B009

B003

B005

B119 B119A

B111

B094

B090

B079

B070

B030

B036

B039

B040

B030A

B069A

B046B049B051

B064

B054

B069B

B069 B075

#3

#4

#5

B508 B506

B556D

B556C

B103

#7 #8

B514A

B535

B540A

B535A

B522A

B629B B629A

B629C B629D

B612 B610

B702

B617 B615 B613 B607 B605

B601

B632

B700

B630

B624

B714

B802

B710

B717

B712

B719 B804

B834 B836

B833 B835

B818

B816

B716

B726

B724

B821 B821A

B821B

B821D B821C

B808

B806

B813

B803

B805

B805A

B705

B805B

B703

B701

B830

B832

B609

B818B

B802A

B801

B614

B601A

B611

B702B

B629

B702

B702C

B626

B628

B837

B556E

B556F

B113

B001

B700A

B002

B020

B080B530

B579

B700B

B815

B728

B622

B007

B707B708

B095

B588A

B580 B581

B582

B582B

B582C

B583

B584

B584A

B585

B586

B587

B582A

B588

B807

B801

B702G B702F B702E B702D

B069C

B618

B833A

B618A

B805C

B632B

B632A

B618C

B618B

B005A

B102

B079A

B526

B526A

B524A

B524A

B503A

10 9

BLDG. 17

AIR CONDITIONING

LAB

COLD ROOM G.C. LAB

STORAGE

LAB

STORAGE

TLT

LOCKERS

RESEARCH

LAB

PLMONARY STORRESEARCH

LAB

OFFICE

BIOMED

BIO MED SHOP/OFFICE

STORAGE

LINEN CHUTE

PLUMBING

SHOP

EMS

EQUIPMENT

STORAGE

WELDING

SHOP

MECHANICAL

HVAC

ELECTRICAL

STORAGE

TELEPHONE

SWITCH

ROOM

OFFICE

PHARMACY STORAGE

STORAGE

WATER

METER

MORGUE

STOR

MORGUE

MECHTLT

COMPRESSED GAS

LINEN CHUTE

JAN

RECEIVING

AREA

OFFICE

WAREHOUSE

STORAGE

STORAGE

PLUMBING

STORAGE

PAINT

ELEVATOR

PIT

MENS TOILET

WOMENS TOILET

MECHANICAL

STORAGE

TRAINING ROOM

CARPENTER SHOP

STOR

OFFICE

EMS OFFICE

OFFICE

STORAGE

HVAC

ELECT

MECHANICAL

OFFICES OFFICE

OFFICE

OFFICE OFFICE

TELECOM

OFFICE D

ELECTRIC

JAN

LOCKER

CLOTHING

ROOM

LINEN

SUPPLY

PHARMACY

OFFICE

STOR

BREAK

IT

VAULT

OFFICE

ELEC

OFFICE

OFFICEOFFICE

OFFICE

OFFICE OFFICE OFFICE

OFFICEOFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICES

OFFICE

OFFICE

CANTEEN

STORAGE

OFFICES

STOR

STORAGE

OFFICE

OFFICE

A/C OPERATORS

EMS

STORAGE

OFFICE

MAIL RM/ COPY

CENTER

MECHANICAL

SPACE

STOR

STOR

BIO HAZZARD/ INFECT

WASTE

MENS

CANTEEN

STORAGELOCK

SHOPREFRESHMENT SHOP

PULMONARY

RESEARCH

OFFICE

STOR

BIOMED SHRED

ROOM

PULMONARY

RESEARCH

LAB

PULMONARY

RESEARCH

LAB

PULMONARY

RESEARCH

LAB

OFFICE

BREAK RM

OFFICE

POLICE SUITE

HOLDING

TRAINING RM

DISPATCH

LOCKERS

ARMORY

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE OFFICE

OFFICE/CUBICLES

STORAGE

RADIO

ACTIVE

MATERIALS

OFFICE

OFFICE

OFFICES

OFFICEOFFICE

OFFICE

VOLUNTEER

SERVICES

OFFICE

OFFICE

PIV

OFFICE

OFFICE

VOLUNTEER

ESCORT

RM

STORAGE

STORAGE

EMS SHOP

OFFICE

CONF RM

ELEVATOR

ELEVATOR

ELEVATOR

ELEVATOR

ELEVATOR

ELEVATOR ELEVATOR

ELEVATOR

ELEVATOR ELEVATOR

ELEVATOR

STAIR

STAIR

STAIR

OPC STAIR

STAIR

STAIR

STAIR

STAIR STAIR

STAIR

OFFICE

STOR

OFFICE

OFFICE

IV RMIV RMIV RM BREAK RM

JANITOR

OFFICE

OFFICE

O.R. CHARGING

STATION

EMS

ELECTRICAL

ANTEROOM

STOR

STOR

ELECTRICAL

SUPPLY RM

WOMENS

OFFICE

DECONTAMINATION

SCOPE

PROCESSING

SCOPE

SCOPEPROCESSING

ANTEROOM

OXIDE

NITROUS

STOR

STOR

ELEVATOR LOBBY

ELEVATOR LOBBY

ELEVATOR

LOBBY

AUTOVALET

UP

UP

UP

UP

UP

UP

UP

DN

UP

UP

UP

BLOCKED

DOOR

BLOCKED

DOOR

8' OVERHEAD DOOR

8' OVERHEAD DOOR 8' OVERHEAD DOOR 8' OVERHEAD DOOR

8' OVERHEAD DOOR8' OVERHEAD DOOR

O V E R H E A D

D O O R

4'8" OVERHEAD DOOR

1 2 3 3.1 4 4.15 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

A

B

C

D

E

F

G

H

J

K

L

M

N

O

P Q

R

S

T

U

V

W

01-TN100TR-A

EXISTING MCR-01

EXISTING TR

EXISTING TR

G ra p h ic S ca le

/1 6"

0"

G ra p h ic S ca le

/1 6"

0"

G ra p h ic S ca le

/8

0"

G ra p h ic S ca le

/3 2"

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

/8

0"

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

G ra p h ic S ca le

/2

0"

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

A/E:Consultant:

Sprinklered

OMAHA EHRM INFRASTRUCTURE

UPGRADE DESIGN

636-21-704

B

IM

/V

IS

N

O m a h a

E H

R M

/6

-7

.B

.T R

.r v t

/1

/2

:1

:3

A

M

BLDG. 01 - LEVEL 00 FLOOR DEMOLITION PLAN -

TECHNOLOGY - OVERALL

PDN DJJ

ISSUED FOR BID

FULLY SPRINKLERED

OMAHA VA MEDICAL CENTER

MAY 15, 2023

Office of Construction and

Facilities Management 01-TD100

1" = 20'-0"

BLDG. 01 - LEVEL 00 FLOOR DEMOLITION PLAN - TECHNOLOGY

2882 106TH STREET

DES MOINES, IA 50322

515.334.9906 FAX: 515.334.9908

www.imegcorp.com # 21005326.00

A

B

D E

C

A

B

D E

C

KEY PLAN NORTHNORTH

KEYNOTES:

1. REMOVE EXISTING COPPER BACKBONE

CABLING, FIBER OPTIC BACKBONE CABLING,

DATA CABLING, VOICE CABLING AND 2-POST

RACKS AFTER COMPLETED SUCCESSFUL

CUTOVER TO NEW TR. EXISTING SECURITY

PANELS SHALL REMAIN IN PLACE.

B721

B818A

B723

OFFICE

SERVER RM

SERVER RM

B802

B717

B719 B804

B834 B836

B833 B835

B818

B816

B716

B726

B724

B821 B821A

B821B

B821D B821C

B808

B806

B813

B805

B805A

B830

B832

B818B

B802A

B801

B837

B815

B728

B807

B833A

B805C

MECHANICAL

STORAGE

TRAINING ROOM

CARPENTER SHOP

STOR

OFFICE

EMS OFFICE

OFFICE

STORAGE

HVAC

ELECT

MECHANICAL

OFFICES OFFICE

OFFICE

OFFICE OFFICE

TELECOM

OFFICE D

ELECTRIC

JAN

LOCKER

CLOTHING

ROOM

OFFICE

OFFICE

OFFICE

PIV

OFFICE

OFFICE

VOLUNTEER

ESCORT

RM

STORAGE

EMS SHOP

OFFICE

STAIR

OPC STAIR

OFFICE

STOR

AUTOVALET

UP

UP

UP

UP

B721

B818A

B723

OFFICE

SERVER RM

SERVER RM

B802

B717

B719 B804

B834 B836

B833 B835

B818

B816

B716

B726

B724

B821 B821A

B821B

B821D B821C

B808

B806

B813

B805

B805A

B830

B832

B818B

B802A

B801

B837

B815

B728

B807

B833A

B805C

MECHANICAL

STORAGE

TRAINING ROOM

CARPENTER SHOP

STOR

OFFICE

EMS OFFICE

OFFICE

STORAGE

HVAC

ELECT

MECHANICAL

OFFICES OFFICE

OFFICE

OFFICE OFFICE

TELECOM

OFFICE D

ELECTRIC

JAN

LOCKER

CLOTHING

ROOM

OFFICE

OFFICE

OFFICE

PIV

OFFICE

OFFICE

VOLUNTEER

ESCORT

RM

STORAGE

EMS SHOP

OFFICE

STAIR

OPC STAIR

OFFICE

STOR

AUTOVALET

UP

UP

UP

UP

B721

B818A

B723

OFFICE

SERVER RM

SERVER RM

B802

B717

B719 B804

B834 B836

B833 B835

B818

B816

B716

B726

B724

B821 B821A

B821B

B821D B821C

B808

B806

B813

B805

B805A

B830

B832

B818B

B802A

B801

B837

B815

B728

B807

B833A

B805C

MECHANICAL

STORAGE

TRAINING ROOM

CARPENTER SHOP

STOR

OFFICE

EMS OFFICE

OFFICE

STORAGE

HVAC

ELECT

MECHANICAL

OFFICES OFFICE

OFFICE

OFFICE OFFICE

TELECOM

OFFICE D

ELECTRIC

JAN

LOCKER

CLOTHING

ROOM

OFFICE

OFFICE

OFFICE

PIV

OFFICE

OFFICE

VOLUNTEER

ESCORT

RM

STORAGE

EMS SHOP

OFFICE

STAIR

OPC STAIR

OFFICE

STOR

AUTOVALET

UP

UP

UP

UP

D

D

1D-WAP

1D-WAP 1D-WAP1D-WAP

1D-CAM

4D4D

V

1D-WAP

2D2V2D

D

D

V

2D 2V 2D 2V

D

V

D

V

D

V

D

V

D

V

1D-WAP

1D-WAP

1D-WAP

1D-WAP

2D2D 2V

4D4D

D

V

D 2D 2V

V

D

V

2D 2V

D

V

D

V

D

1V

1D-CAM

1D-WAP

1D-WAP

D

V

1D 1V 1D 1V 1D 1V 1D 1V

D

V

D

V

D

V

1D1V 1D1V

1D1V 1D1V

1D1V

1D-WAP

1D-WAP

1D-WAP

V

2D2V 2D2V

D

V

2D 2V

2D2V

D

V

D

V

D

V

V

D

V

2D 2V

D

2D 2V

V

D

V

2D2V 3D

D

D

V

D

V

D

V

D

V

2D2V

2D 2V

D

V

D

V

1D-WAP

2D2V D

V

D

V

D

V

D

V

2D 2V 2D 2V

1D-WAP 2D2V

2D 2V

4D 4D

D

D

1 2 3 3.1 4 4.1 5 6 7 8 9 10

A

B

C

D

E

F

OUTLETS IN MODULAR FURNITURE

FED FROM POWER POLE

POWER POLE

CABLING IN THIS ROOM SERVED

FROM WALL MOUNTED RACK

POWER POLE

01-TN100TR-A

EXISTING

SECURITY

PANEL

G ra p h ic S ca le

/1 6"

0"

G ra p h ic S ca le

/1 6"

0"

G ra p h ic S ca le

/8

0"

G ra p h ic S ca le

/3 2"

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

/8

0"

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

G ra p h ic S ca le

/2

0"

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

A/E:Consultant:

Sprinklered

OMAHA EHRM INFRASTRUCTURE

UPGRADE DESIGN

636-21-704

B

IM

/V

IS

N

O m a h a

E H

R M

/6

-7

.B

.T R

.r v t

/1

/2

:1

:3

A

M

BLDG. 01 - LEVEL 00 FLOOR DEMOLITION PLAN -

TECHNOLOGY - QUADRANT A

PDN DJJ

ISSUED FOR BID

FULLY SPRINKLERED

OMAHA VA MEDICAL CENTER

MAY 15, 2023

Office of Construction and

Facilities Management 01-TD100A

1/8" = 1'-0"

BLDG. 01 - LEVEL 00 FLOOR DEMOLITION PLAN - TECHNOLOGY - QUADRANT A

2882 106TH STREET

DES MOINES, IA 50322

515.334.9906 FAX: 515.334.9908

www.imegcorp.com # 21005326.00

A

B

D E

C

A

KEY PLAN NORTH

0 8' 16'4'

SHEET NOTES:

1. REMOVE ALL CABLING AS SHOWN ON THE

FLOOR PLANS. EXISTING ROUGH-IN TO

REMAIN. REFER TO TECHNOLOGY

INSTALLATION NOTES ON 00-TN001.

B590

BLDG. 19

B589

B629B B629A

B629C B629D

B612 B610

B702

B617 B615 B613 B607 B605

B601

B632

B700

B630

B624

B714

B802

B710

B717

B712

B803

B805A

B705

B805B

B703

B701

B609

B614

B601A

B611

B702B

B629

B702

B702C

B626

B628 B700A

B700B

B622

B707B708

B588A B582B

B582C

B583

B584

B584A

B585

B586

B587 B588

B801

B702G B702F B702E B702D

B618

B632B

B632A

10 9

PLUMBING

SHOP

EMS

EQUIPMENT

STORAGE

WELDING

SHOP

MENS TOILET

WOMENS TOILET

CLOTHING

ROOM

LINEN

SUPPLY

PHARMACY

OFFICE

STOR

BREAK

IT

VAULT

OFFICE

ELEC

OFFICE

OFFICEOFFICE

OFFICE

OFFICE OFFICE OFFICE

OFFICEOFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICES

OFFICE

LOCKERS

ARMORY

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE OFFICE

OFFICE/CUBICLES

STORAGE

RADIO

ACTIVE

MATERIALS

OFFICE

OFFICE

OFFICES

OFFICEOFFICE

OFFICE

VOLUNTEER

SERVICES

OFFICE

OFFICE

VOLUNTEER

ESCORT

RM

STORAGE

ELEVATOR ELEVATOR

ELEVATOR

STAIR

STAIR

OFFICE

OFFICE

IV RMIV RMIV RM BREAK RM

JANITOR

O.R. CHARGING

STATION

EMS

ELEVATOR

LOBBY

UP

UP

DN

UP

UP

UP

BLOCKED

DOOR

4'8" OVERHEAD DOOR

B590

BLDG. 19

B589

B629B B629A

B629C B629D

B612 B610

B702

B617 B615 B613 B607 B605

B601

B632

B700

B630

B624

B714

B802

B710

B717

B712

B803

B805A

B705

B805B

B703

B701

B609

B614

B601A

B611

B702B

B629

B702

B702C

B626

B628 B700A

B700B

B622

B707B708

B588A B582B

B582C

B583

B584

B584A

B585

B586

B587 B588

B801

B702G B702F B702E B702D

B618

B632B

B632A

10 9

PLUMBING

SHOP

EMS

EQUIPMENT

STORAGE

WELDING

SHOP

MENS TOILET

WOMENS TOILET

CLOTHING

ROOM

LINEN

SUPPLY

PHARMACY

OFFICE

STOR

BREAK

IT

VAULT

OFFICE

ELEC

OFFICE

OFFICEOFFICE

OFFICE

OFFICE OFFICE OFFICE

OFFICEOFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICES

OFFICE

LOCKERS

ARMORY

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE OFFICE

OFFICE/CUBICLES

STORAGE

RADIO

ACTIVE

MATERIALS

OFFICE

OFFICE

OFFICES

OFFICEOFFICE

OFFICE

VOLUNTEER

SERVICES

OFFICE

OFFICE

VOLUNTEER

ESCORT

RM

STORAGE

ELEVATOR ELEVATOR

ELEVATOR

STAIR

STAIR

OFFICE

OFFICE

IV RMIV RMIV RM BREAK RM

JANITOR

O.R. CHARGING

STATION

EMS

ELEVATOR

LOBBY

UP

UP

DN

UP

UP

UP

BLOCKED

DOOR

4'8" OVERHEAD DOOR

B590

BLDG. 19

B589

B629B B629A

B629C B629D

B612 B610

B702

B617 B615 B613 B607 B605

B601

B632

B700

B630

B624

B714

B802

B710

B717

B712

B803

B805A

B705

B805B

B703

B701

B609

B614

B601A

B611

B702B

B629

B702

B702C

B626

B628 B700A

B700B

B622

B707B708

B588A B582B

B582C

B583

B584

B584A

B585

B586

B587 B588

B801

B702G B702F B702E B702D

B618

B632B

B632A

10 9

PLUMBING

SHOP

EMS

EQUIPMENT

STORAGE

WELDING

SHOP

MENS TOILET

WOMENS TOILET

C…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .