Attachment 07 OMAHA VA EHRM_BID SET_ELECTRICAL - Drawing.pdf
PDF 15 MB Posted
- Attached to
- Y1DA--Copy of EHRM Infrastructure Upgrades - Construction - Omaha VAMC DUPLICATE OF 36C776230036
- Solicitation number
- 36C77623B00361
About this file
This document provides details on a federal contract opportunity for construction services. The solicitation is for infrastructure upgrades at the Omaha Veterans Affairs Medical Center, with the solicitation number 36C77623B00361 from the Department of Veterans Affairs Technology Acquisition Center Austin. The opportunity type is listed as a solicitation. An attachment is included that contains electrical drawings related to the bid set for the project. The solicitation seeks construction services to upgrade infrastructure at the Omaha VAMC facility. The response deadline and anticipated award date are not specified in the provided document.
View the file
Other files
Show all 38
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
POWER SYMBOLS
FIRE ALARM SYMBOLS
DRAWING SYMBOLS
FIRE ALARM NOTES
DEMOLITION NOTES
ELECTRICAL NOTES
LIGHTING NOTES
LIGHTING SYMBOLS
ELECTRICAL PHASING NOTES
KEYNOTE DESIGNATIONS
ELECTRICAL ABBREVIATIONS
GENERAL NOTES
SCOPE OF WORK
DISCONNECT SWITCH, FUSED
DISCONNECT SWITCH, UNFUSED
STARTER, COMBINATION WITH DISCONNECT SWITCH
STARTER OR MOTOR CONTROLLER
TRANSFORMER, PLAN
MOTOR, SINGLE-PHASE
MOTOR, THREE-PHASE
WYE CONNECTION
EARTH GROUND
PULL BOX
WIREWAY
SUBSTATION
BUSWAY
PUSH BUTTON
DISTRIBUTION PANEL
PANELBOARD, FLUSH MOUNTED
PANELBOARD, SURFACE MOUNTED
RECEPTACLE, CLOCK HANGER
RECEPTACLE, DUPLEX
RECEPTACLE, DUPLEX ON EMERGENCY POWER
RECEPTACLE, DUPLEX
WITH GROUND FAULT CIRCUIT INTERRUPTER
RECEPTACLE, QUADRAPLEX
RECEPTACLE, SINGLE
RECEPTACLE, SINGLE WITH SWITCH
RECEPTACLE, SPECIAL PURPOSE:
SEE NOTES ON DRAWINGS FOR TYPE
RECEPTACLE, SWITCHED DUPLEX
HI VOLTAGE SWITCH ON CONCRETE PAD
LOW VOLTAGE SWITCH ON CONCRETE PAD
DROP CORD, SINGLE CONVENIENCE OUTLET, 3-WIRE,
GROUNDING TYPE, 20A, W/#12 CONDUCTORS IN FLEXIBLE
CORD (CENTER LINE OF OUTLET: 6' - 6" [2m] AFF. MIN).
ELECTRICAL STRIP MOLD (OUTLETS ON 2'-0" [60cm]
CENTERS OR AS DESIGNATED ON DRAWINGS),
MOUNTED AT 3'-6" [1m] AFF OR AS INDICATED.
T
PB
S
S
S
HVS
LVS
W W
B B
JUNCTION BOX: SIZE PER N.E.C., REFER TO SPECIFICATIONS FOR
GENERAL CONSTRUCTION, SYMBOL DOES NOT INDICATE ALL
JUNCTION BOXES THAT ARE REQUIRED FOR THIS PROJECT ARE
SHOWN ON PLAN(S).
J JOR
SD FIRE ALARM SMOKE DETECTOR, CEILING MOUNT
F FIRE ALARM HORN/STROBE, WALL MOUNT
FIRE ALARM STROBE, WALL MOUNTF S
F FIRE ALARM PULLSTATION
FAR FIRE ALARM RELAY
H4
H7
A
DETAIL NUMBER
DRAWING NUMBER WHERE SHOWN
SECTION LETTER
DRAWING NUMBER WHERE DRAWN
EXIT LIGHTING, SHADED SECTION(S) DENOTE FACE(S).
USE DIRECTIONAL ARROWS WHERE INDICATED.
WALL MOUNTED LED FIXTURE
LETTER INDICATES TYPE
INDICATES HEIGHT ABOVE FINISHED
GRADE/SURFACE (FT.-IN.)
REFER TO LIGHTING FIXTURE SCHEDULE AND
LIGHTING PLANS FOR DETAILS.
A @ 20'-0"
NOTES:
1. LETTER OR NUMBER DENOTES FIXTURE TYPE, REFER TO LIGHTING FIXTURE
SCHEDULE AND LIGHTING PLANS FOR DETAILS.
2. ALL SYMBOLS SHOWN WITH DASHED LINES DENOTES THAT FIXTURES ARE TO BE
REMOVED - THIS APPLIES ONLY TO DEMOLITION SHEETS.
2' x 4' FIXTURE
2' x 4' EMERGENCY FIXTURE
SWITCH: SINGLE POLE, SINGLE THROW, 120/277 VOLT, 20 AMP.
$ 3
SWITCH: THREE WAY, 120/277 VOLT 20 AMP
$ D
DIMMER: LED ELECTRONIC DRIVERS, 277 VOLT, DECORA STYLE
LINEAR SLIDER OPERATOR WITH POSITIVE OFF. COLOR TO
MATCH DEVICES.
$ D3
DIMMER: THREE WAY, LED ELECTRONIC DRIVERS, 277 VOLT,
DECORA STYLE LINEAR SLIDER OPERATOR WITH POSITIVE OFF.
COLOR TO MATCH DEVICES.
PP
OS
$ OCCUPANCY SENSOR, DUAL TECHNOLOGY, WALL MOUNT
O
POWER PACK, ABOVE CEILING
OCCUPANCY SENSOR, DUAL TECHNOLOGY, CEILING MOUNT
1. EXISTING FIRE ALARM SYSTEM SHALL STAY OPERATIONAL DURING CONSTRUCTION.
PROVIDE NEW OR TEMPORARY FIRE ALARM DEVICES AS NEEDED PER NFPA AND VA
CODE AND REGULATIONS.
2. NEW FIRE ALARM DEVICES WILL CONNECT TO EXISTING FIRE ALARM SYSTEM.
PROVIDE NEW FIRE ALARM DEVICES TO MATCH EXISTING SYSTEM.
3. EXISTING FIRE ALARM SYSTEMS ZONES SHALL BE TESTED PRIOR TO CONNECTING
NEW DEVICES. EXPAND EXISTING FIRE ALARM SYSTEM AS REQUIRED DOE PROPER
OPERATION AND FUNCTION.
4. THE EXISTING FIRE ALARM SYSTEM IS A SIMPLEX 4100U SYSTEM. THE SERVICE
CONTRACTOR IS SIMPLEXGRINNELL. CONTACT LOCAL SIMPLEXGRINNELL. IT IS
RECOMMENDED THAT THE EXISTING FIRE SERVICE CONTRACTOR BE INCLUDED AS
PART OF THE NEW FIRE ALARM WORK TO RETAIN THE KNOWLEDGE OF THE SYSTEM.
5. FIRE ALARM DEVICES ARE INDICATED FOR DESIGN INTENT. DEVICE QUANTITIES
INDICATED ARE MINIMUM. PROVIDE ADDITIONAL DEVICES AS REQUIRED IN THE
RENOVATION SPACES.
6. IN CONSTRUCTION AREAS, REPLACE ALL SMOKE DETECTORS WITH HEAT DETECTORS
DURING CONSTRUCTION. INSTALL NEW SMOKE DETECTORS AT THE SAME LOCATION
OF EXISTING SMOKE DETECTORS AFTER CONSTRUCTION IN THE AREAS.
1. ELECTRICAL CONTRACTOR TO BE RESPONSIBLE FOR AREAS OF DEMOLITION AS
PART OF THIS PROJECT. CONTRACTOR IS TO ALSO TAKE MEASURES AS TO ENSURE
CONTINUITY OF CIRCUITS WHERE REQUIRED DUE TO RENOVATIONS. ANY OUTAGES
WHICH MAY RESULT AS A PART OF THIS PROJECT ARE TO BE COORDINATED WITH
THE COR TWO WEEKS PRIOR TO ANY WORK BEING COMPLETED.
2. ANY WIRING DEVICES, EQUIPMENT, AND LIGHT FIXTURES THAT MAY BE REMOVED
AS PART OF THIS PROJECT ARE TO BE HANDED OVER TO THE OWNER OR
RELOCATED. VERIFY WITH COR.
3. ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE FOR UPDATING SCHEDULES FOR
ANY SWITCHBOARDS AND PANELBOARDS THAT ARE AFFECTED BY THIS PROJECT
AND ARE TO BE TYPEWRITTEN.
4. THE ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE FOR REQUIRED WORK
OUTSIDE THIS PROJECT BOUNDARY NECESSARY TO ENSURE ADJACENT SERVICES
REMAIN ENERGIZED DURING CONSTRUCTION OF THE RENOVATION PROJECT.
5. ALL EXISTING BRANCH CIRCUITS NOT USED ARE TO BE REMOVED BACK TO THE
PANEL. THE CIRCUIT BREAKERS ARE TO BE LABELED AS SPARE. EXISTING
CONDUITS FROM PANEL ARE TO REMAIN TO ABOVE CEILING.
6. ELECTRICAL CONTRACTOR TO PROVIDE COVERS FOR ANY EXISTING OPEN BUSSING
IN PANELBOARDS THAT ARE AFFECTED BY THIS PROJECT.
7. ELECTRICAL CONTRACTOR TO REMOVE ANY AND ALL UNUSED OR ABANDONED
ELECTRICAL EQUIPMENT THAT RESIDES WITHIN THE AREAS OF THE PROJECT
SCOPE.
8. REPAIR OR REPLACE BUILDING ELEMENTS WHICH ARE DAMAGED AS PART OF
DEMOLITION WORK.
9. DISCONNECT MECHNICAL EQUIPMENT BEING REMOVED BY MECHANICAL
CONTRACTOR. COORDINATE EQUIPMENT REMOVAL LOCATIONS WITH MECHANICAL
DRAWINGS.
10. SEE ARCHITECTUAL DRAWINGS FOR ADDITIONAL ELECTRICAL DEMOLITION ITEMS.
DISCONNECT AND REMOVE ELECTRICAL DEVICES, EQUIPMENT, AND ASSOCIATED
WIRING AS REQUIRED TO ACCOMODATE NEW WORK.
11. COORDINATE DEMOLITION WITH THE WORK OF OTHER TRADES.
12. FOR EQUIPMENT AND DEVICES TO BE DEMOLISHED, THE EXISTING CABLING SHALL
BE REMOVED IN IT'S ENTIRETY.
13. PROVIDE BLANK COVERPLATES FOR ABANDONED RECESSED JUNCTION BOXES.
14. ALL ELECTRICAL WORK SHALL COMPLY WITH ALL LOCAL, STATE, AND FEDERAL
CODES, PARTICULARLY THE LATEST APPLICABLE VERSION OF THE NATIONAL
ELECTRICAL CODE (NFPA 70).
15. COORDINATE ANY AND ALL OUTAGES WITH THE OWNER AT LEAST 7 DAYS PRIOR TO
ANY DISRUPTION OF POWER.
16. EXISTING ELECTRICAL SYSTEM IS TO REMAIN IN SERVICE UNLESS OTHERWISE
NOTED. ALL CIRCUITS WHICH ARE DISTURBED BY DEMOLITION OR NEW
CONSTRUCTION ARE TO BE RECONNECTED AT NO ADDITIONAL COST TO THE
OWNER.
17. REMOVE ALL BRANCH CIRCUIT CONDUIT AND CONDUCTORS SERVING EQUIPMENT
AND DEVICES WHICH WILL NO LONGER BE USED, UNLESS OTHERWISE NOTED.
18. REMOVE ALL DEVICES INDICATED BY DARKENED AND DASHED LINES AND
ASSOCIATED KEYED NOTES. REMOVE ALL DEVICES IN WALLS AND CEILINGS WHICH
ARE SHOWN TO BE DEMOLISHED ON ARCHITECTURAL PLANS, WHETHER OR NOT
SUCH DEVICES ARE SHOWN ON THESE PLANS.
19. REMOVE ALL DEVICES, CONDUIT AND CONDUCTORS COMPLETE TO SOURCE
ASSOCIATED WITH MECHANICAL EQUIPMENT WHICH IS BEING DEMOLISHED.
COORDINATE WITH MECHANICAL PLANS FOR DETAILED INFORMATION.
20. WHERE CIRCUITS ARE REMOVED COMPLETELY, RELABEL EXISTING CIRCUIT
BREAKER AS "SPARE". PROVIDE UPDATED PANEL SCHEDULES FOR ALL PANELS
MODIFIED.
21. PORTIONS OF CONDUIT LOCATED WITHIN WALLS OR FLOORS WHICH ARE NOT TO
BE REMOVED MAY REMAIN IN PLACE AT THE CONTRACTOR'S OPTION. HOWEVER,
REMOVE ALL CONDUCTORS COMPLETELY BACK TO THE SOURCE.
22. EXISTING LIGHTING AND LIGHTING CONTROLS ARE TO REMAIN UNLESS OTHERWISE
NOTED ON THE LIGHTING PLANS.
23. THE OWNER SHALL HAVE SALVAGE RIGHTS TO ANY ITEMS THAT ARE TO BE
DEMOLISHED. ITEMS THAT THE OWNER WISHES TO SALVAGE SHALL BE CAREFULLY
REMOVED AND STORED IN A LOCATION AS DIRECTED BY THE OWNER. ALL OTHER
ITEMS OF DEMOLITION SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND
SHALL BE REMOVED FROM THE SITE.
24. FOR LIGHTING FIXTURES TO BE REMOVED, TURN FIXTURES AND ASSOCIATED
COMPONENTS TO THE VA FOR FUTURE USE. FOR LIGHTING FIXTURES TO BE
RELOCATED/REINSTALLED, PROVIDE NEW LAMP (FOR NON-LED TYPE) AND CLEAN
PRIOR TO REINSTALLATION.
1. FIRE STOP SHALL BE PROVIDED AT ALL LOCATIONS WHERE ELECTRICAL EQUIPMENT
OR SYSTEMS PENETRATE FIRE RATED WALLS. SEE ARCHITECTURAL PLANS FOR
RATED WALL LOCATIONS.
2. CONTROL WIRING TO MECHANICAL EQUIPMENT IS NOT SHOWN ON THESE SHEETS.
3. ONE-LINE DIAGRAMS ARE MEANT TO SHOW ONLY ELECTRICAL RELATIONSHIPS AND
THEREFORE MAY NOT INCLUDE ALL REQUIRED EQUIPMENT, DEVICES AND
ACCESSORIES.
4. ALL ELECTRICAL WORK SHALL COMPLY WITH ALL LOCAL, STATE, AND FEDERAL
CODES, PARTICULARLY THE LATEST APPLICABLE VERSION OF THE NATIONAL
ELECTRIC CODE (NFPA 70).
5. ELECTRICAL CONTRACTOR SHALL COORDINATE REQUIREMENTS OF ALL EQUIPMENT
PROVIDED BY OTHER TRADES PRIOR TO ROUGH-IN.
6. SWITCHGEAR, SWITCHBOARDS AND PANELBOARDS SHALL BE CONSTRUCTED AND
ASSEMBLED BY THE SAME MANUFACTURER THAT PRODUCES THE PROTECTIVE
DEVICES HOUSED IN THE COMPLETE LINE-UP, HOUSING, OR ENCLOSURE.
7. DO NOT SCALE DRAWINGS. IF EXACT LOCATION OF EQUIPMENT CANNOT BE
DETERMINED CONTACT THE ARCHITECT/ENGINEER FOR DIRECTION.
8. ALL SIZES ARE BASED ON COPPER CONDUCTORS. SIZES SHALL NOT BE LESS THAN
INDICATED.
9. ELECTRICAL CONTRACTOR SHALL NOT SHARE NEUTRALS, UNLESS SPECIFICALLY
NOTED OTHERWISE. ALL LIGHTING CIRCUITS SHALL HAVE A SEPARATE INSULATED
GROUNDING CONDUCTOR INSTALLED WITH EACH CIRCUIT.
10. ALL HEIGHTS OF ELECTRICAL DEVICES NOTED SHALL BE TO THE CENTER OF THE
DEVICE.
1. ELECTRICAL CONTRACTOR SHALL PULL UNSWITCHED LEG FOR CONNECTION OF
EMERGENCY/EXIT LIGHTS.
2. CIRCUIT ALL EXTERIOR LIGHTING THROUGH ONE PHOTOCELL RELAY PER CIRCUIT.
3. REFER TO ARCHITCTURAL LAYOUT FOR LOCATION OF EXIT LIGHTS.
4. ALL LIGHT FIXTURES MAY HAVE AN EQUAL BUT REQUIRE APPROVAL BY ENGINEER
AND OWNER. ALL LIGHT FIXTURE PRIOR APPROVALS MUST BE IN WRITING. THE
ENGINEER RESERVERS THE RIGHT TO REQUIRE “TABLE TOP” TESTING OF ANY
FIXTURE SUBMITTED AS AN EQUAL.
5. ALL LIGHTS MOUNTED IN EXPOSED STRUCTURE AREAS SHALL BE FINISHED BLACK.
6. ALL RECESSED LIGHTING FIXTURES MUST BE INSTALLED TO PROVIDE A NON-
COMBUSTIBLE FIRE RATED ASSEMBLY.
7. COORDINATE ALL LIGHT FIXTURE MOUNTING REQUIREMENTS WITH REFLECTED
CEILING PLAN PRIOR TO RELEASE OF FIXTURE.
8. FOR ACTUAL LOCATIONS OF CEILING MOUNTED FIXTURES AND EQUIPMENT SEE
ARCHITECTURAL REFLECTED CEILING PLANS.
1' x 4' STRIP LED FIXTURE
1' x 4' STRIP LED EMERGENCY FIXTURE
C
RECEPTACLE, QUADRAPLEX ON EMERGENCY POWER
MOTOR RATED TOGGLE SWITCH WITH OVERCURRENT
PROTECTION
M
RECEPTACLE, SPECIAL PURPOSE ON EMERGENCY POWER:
SEE NOTES ON DRAWINGS FOR TYPE
1. THE EXISTING CAMPUS SUPPORT CENTER (SERVER ROOM), MAIN TELEPHONE
EQUIPMENT ROOM, AND TR ROOMS WILL NEED TO REMAIN OPERATIONAL DURING
CONSTRCUTION. EXISTING ELECTRICAL PANELS AND CONNECTIVITY SHALL REMAIN
OR PROVIDE TEMPERARY ELECTRICAL PANELS AND CIRCUITS AS REQUIRED.
COORDINATE WITH VA COR AND SCHEDULES FROM OTHER TRADES FOR EXACT
ELECTRICAL WORK.
2. ELECTRICAL DEMOLITION WORK IN NEW TR SPACES SHALL FOLLOW OTHER
DISCIPLINES' WORK SCHEDULES.
3. ELECTRICAL EQUIPMENT SHALL BE DE-ENERGIZED BEFORE WORKING ON THEM.
ELECTRICAL CONTRACTOR SHALL COORDINATE WITH VA COR FOR EXISTING
ELECTRICAL SYSTEM TIE-INS AND SYSTEM DOWNTIME NEEDED. PROVIDE SCHEDULE
TO VA COR AT LEAST TWO WEEKS PRIOR TO ELECTRICAL WORK.
4. PERFORM ELECTRICAL WORK IN WEEKENDS AND EVENINGS AS NEEDED TO REDUCE
INTERRUPTION OF FACILITY'S NORMAL OPERATION.
KEYNOTE SYMBOL ON SHEET
KEYNOTES
1. THIS IS AN EXAMPLE OF WHAT KEYNOTE 1 COULD BE.
2. THIS IS AN EXAMPLE OF WHAT KEYNOTE 2 COULD BE.
3. THIS IS AN EXAMPLE OF WHAT KEYNOTE 3 COULD BE.
KEYNOTE NUMBER (ON SHEET)
KEYNOTE DESCRIPTION
1PH SINGLE-PHASE
1P SINGLE POLE
2/C TWO-CONDUCTOR
3/C THREE-CONDUCTOR
3PH THREE-PHASE
4/C FOUR-CONDUCTOR
4W FOUR-WIRE
A/C UNIT AIR CONDITIONING UNIT
AAP ALARM ANNUNCIATOR PANEL
AC ALTERNATING CURRENT OR ARMORED CABLE
ACC ACCESSIBLE
ADDL ADDITIONAL
ADJ ADJACENT, ADJOINING
AF AMPERE FRAME OR AMP FUSE
AFC ABOVE FINISHED COUNTER
AFCI ARC-FAULT CURRENT INTERRUPTER
Ah AMPERE HOUR
AHJ AUTHORITY HAVING JURISDICTION
AIC AMPERE INTERRUPTING CAPACITY
ALT ALTERNATE AMP AMPERE
ASC AMPS SHORT CIRCUIT
AT AMPERE TRIP
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AV AUDIO VISUAL
BAT BATTERY
BD BOARD
BFF BELOW FINISH FLOOR
BRKR BREAKER
BYP BY PASS
C CONDUIT
CAB CABINET
CALC CALCULATE
CAP CAPACITY
CAT CATALOG
CATV COMMUNITY ANTENNA TELEVISION
CCR CONTROL CONTACTOR
CCTV CLOSED CIRCUIT TELEVISION
cd CANDELA
CF CONTRACTOR FURNISHED
CF/CI CONTRACTOR FURNISHED/CONTRACTOR INSTALLED
CF/OI CONTRACTOR FURNISHED/OWNER INSTALLED
CFE CONTRACTOR FURNISHED EQUIPMENT
CHW CHILLED WATER
CHWP CHILLED WATER PUMP
CKT CIRCUIT
CKT BRKR CIRCUIT BREAKER OR C/B
CLF CURRENT LIMITING FUSE CLG CEILING
COAX COAX CABLE
COMM COMMUNICATION
COMPT COMPARTMENT
CONC CONCRETE
CONT CONTINUE
CONTR CONTRACTOR
COORD COORDINATE
CPT CONTROL POWER TRANSFORMER
CRI COLOR RENDERING INDEX
CT CURRENT TRANSFORMER
CTV CABLE TELEVISION
CU COPPER
CUR CURRENT
DC DIRECT CURRENT
DCP DIMMER CONTROL PANEL
DIAG DIAGRAM
DISC DISCONNECT
DISTR PNL DISTRIBUTION PANEL
DMR SW DIMMER SWITCH
DPDT DOUBLE POLE, DOUBLE THROW
DPST DOUBLE POLE, SINGLE THROW
DRSW DOOR SWITCH DS DISCONNECT SWITCH
ELEC ELECTRIC OR ELECTRICAL
ELEV ELEVATOR
EMER EMERGENCY
EMI ELECTROMAGNETIC INTERFERENCE
EMT ELECTRICAL METALLIC TUBING
ENCL ENCLOSURE
EPO EMERGENCY POWER OFF
EPRF EXPLOSION PROOF
ESC ESCUTCHEON
EWC ELECTRIC WATER COOLER
EWH ELECTRIC WATER HEATER
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FACP FIRE ALARM CONTROL PANEL
FC FOOTCANDLE
FIXT FIXTURE
FLA FULL LOAD AMPS
FLUOR FLUORESCENT
FP FIRE PROTECTION
FU SW FUSED SWITCH
FVNR FULL VOLTAGE NON-REVERSING
FVR FULL VOLTAGE REVERSING
G ELECTRICAL GROUND
GEN GENERATOR
GFI GROUND FAULT CIRCUIT INTERRUPTER
HID HIGH INTENSITY DISCHARGE
HOA HAND-OFF-AUTOMATIC
IMC INTERMEDIATE METAL CONDUIT
INCAND INCANDESCENT
IR INFRARED
J-BOX JUNCTION BOX
kV KILOVOLT kVA KILOVOLT AMPERE kVAh KILOVOLT AMPERE PER HOUR kVAR KILOVOLT AMPERE REACTIVE kW KILOWATT kWh KILOWATT HOUR kWhM KILOWATT HOUR METER
LED LIGHT EMITTING DIODE
LPS LOW PRESSURE SODIUM
LRA LOCKED ROTOR AMPS
LT LIGHT
LTG LIGHTING
LTG PNL LIGHTING PANEL
LTNG LIGHTNING
LV LOW VOLTAGE
MC METAL-CLAD
MCA MINIMUM CIRCUIT AMPS
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MOCP MAXIMUM OVERCURRENT PROTECTION
MLO MAIN LUGS ONLY
MT MOUNT MTD MOUNTED
MTG MOUNTING
MTS MANUAL TRANSFER SWITCH
MV MEDIUM VOLTAGE
MVA MEGAVOLT-AMPERE
MW MEGAWATT
NC NORMALLY CLOSED
NEUT NEUTRAL (OR N)
NL NIGHT LIGHT
NO NORMALLY OPEN
OL OVERLOAD
P POLE
PB PULL BOX
PEC PHOTOELECTRIC CELL
PED PEDESTAL
PEND PENDANT
PF POWER FACTOR
PH PHASE
PNL PANEL
PT POTENTIAL TRANSFORMER
PVC POLYVINYL CHLORIDE (PLASTIC)
PWR POWER
RCP REFLECTED CEILING PLAN
REC RECESSED
RECEP RECEPTACLE
RMS ROOT MEAN SQUARE
SCC SHORT CIRCUIT CAPACITY
SD SMOKE DETECTOR
SPST SINGLE POLE, SINGLE THROW
SURF SURFACE
SW SWITCH
SWBD SWITCHBOARD
SWGR SWITCHGEAR
TEL TELEPHONE
TV TELEVISION
UFD UNDERFLOOR DUCT
UGND UNDERGROUND
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTIBLE POWER SUPPLY
V VOLT
VA VOLT AMPERE
VAR VOLT AMPERE REACTIVE
VFD VARIABLE FREQUENCY DRIVE
VOLT VOLTAGE
WH WATER HEATER
WP WEATHERPROOF
XFMR TRANSFORMER
RECEPTACLE, ABOVE COUNTER QUADRAPLEX
AC
NO SCOPE OF WORK ASSOCIATED IN SHADED AREA
1. INSTALL GREEN INSULATED GROUND WIRE WITH EACH LIGHTING, RECEPTACLE, AND
EQUIPMENT BRANCH CIRCUIT.
2. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT
REQUIRING A NEUTRAL, UNLESS OTHERWISE NOTED.
3. CONCEAL CONDUITS INSTALLED IN NEW WALLS, EXISTING STUD WALLS AND IN AREAS
WITH SUSPENDED CEILINGS.
4. REPAIR OR REPLACE BUILDING ELEMENTS THAT ARE DAMAGED AS PART OF
ELECTRICAL WORK.
5. SEAL PENETRATIONS IN FIRE RATED CONSTRUCTION TO MAINTAIN RATINGS.
6. REFER TO ARCHITECTURAL ELEVATIONS AND SECTIONS FOR EXACT DEVICE
LOCATIONS.
7. COORDINATE PHASING REQUIREMENTS, BOUNDARIES, ETC., WITH ARCHITECTUAL
DRAWINGS AND DETAILS.
8. PROVIDE POWER CONNECTION TO CONTROL PANELS, TRANSFORMERS, AND OTHER
ITEMS FURNISHED BY MECHANICAL CONTRACTOR FOR HVAC CONTROL. COORDINATE
LOCATIONS OF DEVICES REQUIRING POWER CONNECTIONS WITH MECHANICAL
CONTRACTOR.
9. LABEL OUTLET WALL PLATES WITH CORRESPONDING PANEL AND CIRCUIT NUMBER.
10. REFER TO ARCHITECTUAL FINAL FURNITURE AND EQUIPMENT LOCATIONS FOR
POWER AND COMMUNICATIONS DEVICE AND CONNECTIONS.
11. FIRE ALARM DEVICES ARE INDICATED SCHEMATICALLY FOR DESIGN INTENT. DEVICE
QUANTITIES INDICATED ARE MINIMUM. PROVIDE ADDITIONAL DEVICES AS REQUIRED
PER CODE.
12. POWER OUTLETS SHALL BE MOUNTED 18" AFF OR OTHERWISE AS NOTED.
13. WALL MOUNTED LIGHTING CONTROL DEVICES SHALL MATCH EXISTING IN THE
FACILITY.
14. FIRE ALARM DEVICE MOUNTING HEIGHTS SHALL MATCH EXISTING IN THE FACILITY.
15. POWER OUTLETS ON GENERATOR POWER SHALL BE RED AND WITH RED
COVERPLATES.
16. PROVIDE HOUSE KEEPING PAD FOR ALL FLOOR MOUNTED EQUIPMENT.
2' x 2' FIXTURE
2' x 2' EMERGENCY FIXTURE
1' x 2' STRIP LED FIXTURE
1' x 2' STRIP LED EMERGENCY FIXTURE
G ra p h ic S ca le
/1 6"
0"
G ra p h ic S ca le
/1 6"
0"
G ra p h ic S ca le
/8
0"
G ra p h ic S ca le
/3 2"
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
/8
0"
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
1' -0
G ra p h ic S ca le
/2
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
NOT FOR
PERMITTING OR
CONSTRUCTION
A/E:Consultant:
Approved: Spinklered
Office of Construction and Facilities Management FULLY SPRINKLERED
B
IM
/V
IS
N
O m a h a
E H
R M
/O m a h a
E H
R M
V
.r vt
/1
/2
:0
:2
P
M
YW PPMAY 15, 2023
E-001
636 - OMAHA VA MEDICAL CENTER
ISSUE FOR BIDELECTRICAL LEGEND, NOTES, AND
ABBREVIATIONS
636-21-704OMAHA EHRM INFRASTRUCTURE
UPGRADE DESIGN
ROOMS IN SCOPE - ELECTRICAL
LEVEL NUMBER
NAME
ELECTRICAL DEMO
REQUIRED
ELECTRICAL NEW
REQUIRED
BUILDING 01
BASEMENT B721 TELECOMMUNICATIONS RM. Yes Yes
BASEMENT B611 TELECOMMUNICATIONS RM. Yes Yes
BASEMENT B024C TELECOMMUNICATIONS RM. Yes Yes
BASEMENT B808 TELECOMMUNICATIONS RM. No No
BASEMENT B818A TELECOMMUNICATIONS RM. Yes Yes
BASEMENT 1678 TELECOMMUNICATIONS RM. No No
BASEMENT 1679 TELECOMMUNICATIONS RM. No No
LEVEL 01 1616 TELECOMMUNICATIONS RM. Yes Yes
LEVEL 01 1656 TELECOMMUNICATIONS RM. Yes Yes
LEVEL 01 1205B TELECOMMUNICATIONS RM. Yes Yes
LEVEL 01 1510 TELECOMMUNICATIONS RM. Yes Yes
LEVEL 02 2255A TELECOMMUNICATIONS RM. Yes Yes
LEVEL 02 2448 TELECOMMUNICATIONS RM. Yes Yes
LEVEL 03 3254B TELECOMMUNICATIONS RM. Yes Yes
LEVEL 04 4374A TELECOMMUNICATIONS RM. Yes Yes
LEVEL 05 5414 TELECOMMUNICATIONS RM. Yes Yes
LEVEL 06 6414 TELECOMMUNICATIONS RM. Yes Yes
LEVEL 07 7414 TELECOMMUNICATIONS RM. Yes Yes
LEVEL 08 8414 TELECOMMUNICATIONS RM. Yes Yes
LEVEL 09 9414 TELECOMMUNICATIONS RM. Yes Yes
LEVEL 10 10414 TELECOMMUNICATIONS RM. Yes Yes
LEVEL 11 11414 TELECOMMUNICATIONS RM. Yes Yes
LEVEL 12 12018 TELECOMMUNICATIONS RM. Yes Yes
LEVEL 14 14002 TELECOMMUNICATIONS RM. Yes Yes
BUILDING 02
LEVEL 02 202 TELECOMMUNICATIONS RM. Yes Yes
BUILDING 06
LEVEL 01 109 TELECOMMUNICATIONS RM. Yes Yes
BUILDING 08
LEVEL 01 104A TELECOMMUNICATIONS RM. Yes Yes
BUILDING 09
BASEMENT B12A TELECOMMUNICATIONS RM. Yes Yes
BUILDING 15
LEVEL 02 R220 TELECOMMUNICATIONS RM. Yes Yes
LEVEL 02 R200A TELECOMMUNICATIONS RM. Yes Yes
BUILDING ACC
BASEMENT G011 TELECOMMUNICATIONS RM. Yes Yes
BASEMENT G433 TELECOMMUNICATIONS RM. Yes Yes
LEVEL 01 1011 TELECOMMUNICATIONS RM. Yes Yes
LEVEL 01 1433 TELECOMMUNICATIONS RM. Yes Yes
LEVEL 02 2011 TELECOMMUNICATIONS RM. Yes Yes
LEVEL 02 2433 TELECOMMUNICATIONS RM. Yes Yes
BUILDING D
LEVEL 01 109 TELECOMMUNICATIONS RM. Yes Yes
LIGHT FIXTURE SCHEDULE
Type Mark Description Manufacturer Model Lamp Voltage Apparent Load (VA) Comments
A 4' LED STRIP LIGHT WITH INTEGRAL SENSOR LITHONIA LIGHTING CLX-L48-5000LM-HEF-SBLW-WDL-WD-EZ1-35K-90CRI-N100-NESPDT7 LED MVOLT 44 VA BASE DESIGN. OR APPROVED EQUAL.
AC 4' LED STRIP LIGHT WITH INTEGRAL SENSOR AND EMERGENCY POWER PACK LITHONIA LIGHTING CLX-L48-5000LM-HEF-SBLW-WDL-WD-EZ1-35K-90CRI-N100-NESPDT7-PS1050 LED MVOLT 44 VA BASE DESIGN. OR APPROVED EQUAL.
B 2' LED STRIP LIGHT WITH INTEGRAL SENSOR LITHONIA LIGHTING CLX-L24-3500LM-HEF-SBLW-WDL-WD-EZ1-35K-90CRI-N100-NESPDT7 LED MVOLT 24 VA BASE DESIGN. OR APPROVED EQUAL.
BC 2' LED STRIP LIGHT WITH INTEGRAL SENSOR AND EMERGENCY POWER PACK LITHONIA LIGHTING CLX-L24-3500LM-HEF-SBLW-WDL-WD-EZ1-35K-90CRI-N100-NESPDT7-PS1050 LED MVOLT 24 VA BASE DESIGN. OR APPROVED EQUAL.
C 4' LED STRIP LIGHT WITH EMERGENCY POWER PACK LITHONIA LIGHTING CLX-L48-5000LM-HEF-SBLW-WDL-WD-EZ1-35K-90CRI-PS1050 LED MVOLT 44 VA BASE DESIGN. OR APPROVED EQUAL.
D 2 X 2 FLAT PANEL RECESSED LITHONIA LIGHTING SPX-2X2-3400LM-90CRI-35K-MPL-MIN1-EZT-MVOLT-NW LED MVOLT 35 VA BASE DESIGN. OR APPROVED EQUAL.
S1 LED LIGHT POLE LITHONIA LIGHTING DSX1 LED P3 30K T3M MVOLT SPA DNAXD - 80 CRI LED MVOLT 102 VA BASE DESIGN. OR APPROVED EQUAL. POLE SHALL BE
28' SQUARE STRAIGHT
STEEL POLE WITH INTERNAL VIBRATION DAMPENERS.
W1 LED WALL PACK WITH EMERGENCY POWER PACK LITHONIA LIGHTING TWX2-P1-30K-MVOLT-PE-DDBXD LED MVOLT 23 VA BASE DESIGN. OR APPROVED EQUAL.
W2 LED WALL PACK WITH EMERGENCY POWER PACK LITHONIA LIGHTING TWX2-P4-30K-MVOLT-PE-DDBXD LED MVOLT 54 VA BASE DESIGN. OR APPROVED EQUAL.
LIGHTING FIXTURE SCHEDULE NOTES:
1. PENDANT MOUNT FIXTURE IN TR ROOMS SHALL BE COORDINATED WITH OTHER TRADES. FIXTURES SHALL NOT BE INSTALLED ON TOP OF RACKS, MECHANIVAL UNITS, AND CABLE TRAYS. ADJUST FIXTURE LOCATION AS NEEDED.
2. MOUNT FIXTURE 9'-0'' AFF WHERE ROOM HEIGHT ALLOWS. MOUNTING HEIGHT SHALL BE ADJUSTED WHERE CONFLICTS WITH OTHER ELEMENTS IN ROOM.
3. LIGHTING SYSTEM IN MCR ROOM SHALL BE CONTROLLED FOR THREE LEVEL LIGHTING PROTOCOL:
-LEVEL 1: UNOCCUPIED MODE - SET OCCUPANCY SENSORS AT 20% OUTPUT FOR LIGHT FIXTURE(S) TO ALLOW ENOUGH LIGHT LEVEL FOR CCTV CAMERA TO FUNCTION.
-LEVEL 2: ENTRY MODE - SET OCCUPANCY SENSORS TO ACTIVATE LIGHTS AT THE ENTRY AREA., OTHER LIGHTS AT 50% OUTLPUT -LEVEL 3: OCCUPIED MODE - 100% OUTPUT, LIGHTS SHALL BE ALL ON AND PROVIDE MINIMUM 500 LUX IN THE HORIZONTAL PLANE AND 200 LUX IN THE VERTICAL PLANE, MEASURED 3 FT ABOVE THE FINISHED FLOOR IN FRONT AND BAKC OF CABINETS, OR
THE MIDDLE OF ALL AISLES BETWEEN CABINETS.
4. LIGHTING SYSTEMS IN TR ROOMS SHALL BE CONTROLLED FOR TWO LEVEL LIGHTING PROTOCOL:
-LEVEL 1: UNOCCUPIED MODE - SET OCCUPANCY SENSORS AT 20% OUTPUT FOR LIGHTING FIXTURES TO ALLOW ENOUGH LIGHT FOR CCTV CAMERA TO FUNCTION.
-LEVEL 2: OCCUPIED MODE - 100% OUTPUT. LIGHTS SHALL BE ALL ON AND PROVIDE MINIMUM 500 LUX IN THE HORIZONTAL PLANE AND 200 LUX IN THE VERTICAL PLANE, MEASURED 3FT ABOVE THE FINISHED FLOOR IN FRONT AND BACK OF THE AISLES BETWEEN CABINETS.
5. LIGHTING FIXTURE SHALL BE PROVIDED WITH ALL NECESSARY HARDWARE, CONNECTORS, CONTROLLERS, SENSORS, AND CONTROL CABLES.
Revisions: Date:
NOT FOR
PERMITTING OR
CONSTRUCTION
G
ONE
WAY
ONE
WAY
E E
E
E
E
AC
AC AC
AC
AC
AC
AC
E E
E
E
E
AC
AC AC
AC
AC
AC
AC
E E
E
E
E
AC
AC AC
AC
AC
AC
AC
E E
E
E
E
AC
AC AC
AC
AC
AC
AC
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E E
E
E
E
E
E
E
E
E
E
AC
AC AC
AC
AC
AC
AC
GG
DEMO KEYED NOTES:
SCOPE OF WORK
3TYP.
B1
B24
GENERATORS
B6
B15
ACC
B8
B9
B2
PARKING GARAGE
NO SCOPE OF WORK ASSOCIATED IN SHADED AREA
1 UNDERGROUND ELECTRICAL CIRCUIT TO REMAIN. PROTECT DURING
CONSTRUCTION.
2 DISCONNECT AND REMOVE LIGHT POLE FOR RELOCATION.
3 EXISTING LIGHT POLE TO REMAIN,
4 UNDERGROUND ELECTRICAL FEEDER AND DUCTBANK TO REMAIN, PROTECT
DURING CONSTRUCTION.
G ra p h ic S ca le
/1 6"
0"
G ra p h ic S ca le
/1 6"
0"
G ra p h ic S ca le
/8
0"
G ra p h ic S ca le
/3 2"
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
/8
0"
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
1' -0
G ra p h ic S ca le
/2
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
NOT FOR
PERMITTING OR
CONSTRUCTION
A/E:Consultant:
Approved: Spinklered
Office of Construction and Facilities Management FULLY SPRINKLERED
B
IM
/V
IS
N
O m a h a
E H
R M
/O m a h a
E H
R M
V
.r vt
/1
/2
:0
:2
P
M
YW PPMAY 15, 2023
ES-100
636 - OMAHA VA MEDICAL CENTER
ISSUE FOR BIDELECTRICAL SITE PLAN 636-21-704OMAHA EHRM INFRASTRUCTURE
UPGRADE DESIGN
1/64" = 1'-0"1
ELECTRICAL SITE PLAN - DEMOLITION
Revisions: Date:
NOT FOR
D
D
D
D
D
D
D
D
D
D D
D
F u e l A r t ic
T R
A N
S O
FT
S c
T ra n so f t
So lut ion s
In c
A ll r igh t s re s er v ed
ONE
WAY
G
5'
5'
5'
5'
5'
4.9986
NEW WORK KEYED NOTES:
SCOPE OF WORK
TYP.
3TYP.
S1
S1
S1
NEW
FUEL
TANK
NEW
GENERATOR
BUILDING
G-EP100
1 S1
EXISTING SERVICE
SWITCHGEAR
FIBER CABLES,
SEE ''T'' SHEETS
TYP.
NO SCOPE OF WORK ASSOCIATED IN SHADED AREA
1 RELOCATED LIGHT POLE. CONNECT TO EXISTING LIGHT POLE CIRCUIT AND
CONTROL. PROVIDE NEW FOUNDATION.
2 NEW LIGHT POLE. CONNECT TO EXISTING LIGHT POLE CIRCUIT AND CONTROL IN
THE AREA. SEE DETAIL ON THIS SHEET FOR LIGHT POLE FOUNDATION.
3 EXISTING LIGHT POLE TO REMAIN.
4 CONNECT TO SERVICE SWITCHGEAR IN BUILDING. ROUTE FEEDER THROUGH
EXISTING MANHOLE AND UNDERGROUND CONDUIT PATH, STUB CONDUIT UP TO
SWITCHGEAR.
5 CONDUITS ENTER BUILDING IN BASEMENT MECHANICAL ROOM. SEE SHEET
EP-101 FOR CONTINUATION.
6 (2) 5" UNDERGROUND CONDUIT IN CONCRETE ENCASEMENT FOR NEW MEDIUM
VOLTAGE FEEDERS. ONE OF THE CONDUITS IS SPARE.
7 (8) 4" CONDUITS IN CONCRETE ENCASED DUCTBANK.
8 UNDERGROUND PULLBOX, 18"X24"X12".
DEPTHS SHOWN IN TABLE
ARE FOR GRADES FLATTER
THAN 1:4. FOR GRADES UP
TO 1:2, ADD 2'-6" TO
FOUNDATION DEPTHS
SHOWN IN TABLE.
PLAN
FOOTING DEPTH TABLE
POLE
HEIGHT
(MAX)
8' 12' 20' 30' 40'
FOOTING
DEPTH
(MIN)
3'-6" 4'-6" 5'-6" 7'-0" 8'-0"
24" DIAMETER_
ELEVATION
0.75" X 10' COPPER-CLAD GROUND ROD. BOND TO POLE BASE USING #6 AWG BARE
COPPER AND PROVIDE LUG AND EXOTHERMIC WELDS TO ROD AND REBAR. LUG SHALL
BE APPROVED FOR COPPER WIRE AND POLE MATERIAL CONNECTION.
PROVIDE RIGID STEEL CONDUIT AND ELBOW POURED IN CONCRETE POLE BASE.
TRANSITION TO SCHEDULE 40 PVC AT 2' PAST POLE BASE (TYPICAL).
PROVIDE (8) #6 VERTICAL STEEL REINFORCEMENT BARS AND #3 HORIZONTAL STEEL
RING BARS 6"OC OR A 0.375" SPIRAL HOOP WITH A 6" PITCH (TYPICAL).
INSTALL ALL REINFORCEMENT BARS AND MAINTAIN A MINIMUM OF 3" CONCRETE COVER
(TYPICAL).
PROVIDE 3500 PSI CONCRETE POLE BASE.
PAVING OR GROUND LINE WHERE APPLICABLE.
HEIGHT ABOVE PAVED AREAS OR GROUND LEVEL.
SMOOTH FINISH CONCRETE WITH 45° CHAMFER EDGE. AFTER LEVELING, GROUT
BETWEEN CONCRETE SURFACE AND BASE COVER.
ANCHOR BOLTS TO BE 40" MINIMUM BELOW GRADE WITH ALIGNERS. QUANTITY (4
MINIMUM), CIRCLE DIAMETER AND BOLT SIZE SHALL BE AS RECOMMENDED BY POLE
MANUFACTURER. PROVIDE FULL BASE COVER.
2"x4" MINIMUM HAND HOLE COVER WITH STAINLESS STEEL TAMPER-PROOF SCREWS.
PROVIDE IN-LINE FUSE(S) PER PHASE CONDUCTOR INSIDE HAND HOLE.
EXTEND CONDUIT A MINIMUM OF 3" ABOVE POLE BASE.
LIGHT POLE, SEE FIXTURE SCHEDULE.
LOCATE FACE OF CONCRETE POLE BASE 18" FROM BACK OF CURB (TYPICAL WHERE
APPLICABLE).
(S E
E F
O O
T
IN
G D
E P
T H
T A
B L E
M
IN
IM
U
M
12 10
G ra p h ic S ca le
/1 6"
0"
G ra p h ic S ca le
/1 6"
0"
G ra p h ic S ca le
/8
0"
G ra p h ic S ca le
/3 2"
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
/8
0"
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
1' -0
G ra p h ic S ca le
/2
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
NOT FOR
PERMITTING OR
CONSTRUCTION
A/E:Consultant:
Approved: Spinklered
Office of Construction and Facilities Management FULLY SPRINKLERED
B
IM
/V
IS
N
O m a h a
E H
R M
/O m a h a
E H
R M
V
.r vt
/1
/2
:0
:2
P
M
YW PPMAY 15, 2023
ES-101
636 - OMAHA VA MEDICAL CENTER
ISSUE FOR BIDELECTRICAL SITE PLAN 636-21-704OMAHA EHRM INFRASTRUCTURE
UPGRADE DESIGN
1/64" = 1'-0"1
ELECTRICAL SITE PLAN - NEW WORK
NTS2
DETAIL - LIGHT POLE BASE
Revisions: Date:
NOT FOR
DEMO KEYED NOTES:
GENERAL NOTES
B501
B502
B721
B818A
B723
OFFICE
SERVER RM
SERVER RM
B590
B577
B556B
B556
B556A B551A
B551 B545
B514
B542
B540
B537
B533AA
B533A
B533
B522
B504 B500
A101
#1
#2
BLDG. 19
B589 B024
B505 B505A
B503
B024A
B024AA
B024E
B024C
B024D B024F
B025
B009A
B009
B003
B005
B119 B119A
B111
B094
B090
B079
B070
B030
B036
B039
B040
B030A
B069A
B046B049B051
B064
B054
B069B
B069 B075
#3
#4
#5
B508 B506
B556D
B556C
B103
#7 #8
B514A
B535
B540A
B535A
B522A
B629B B629A
B629C B629D
B612 B610
B702
B617 B615 B613 B607 B605
B601
B632
B700
B630
B624
B714
B802
B710
B717
B712
B719 B804
B834 B836
B833 B835
B818
B816
B716
B726
B724
B821 B821A
B821B
B821D B821C
B808
B806
B813
B803
B805
B805A
B705
B805B
B703
B701
B830
B832
B609
B818B
B802A
B801
B614
B601A
B611
B702B
B629
B702
B702C
B626
B628
B837
B556E
B556F
B113
B001
B700A
B002
B020
B080B530
B579
B700B
B815
B728
B622
B007
B707B708
B095
B588A
B580 B581
B582
B582B
B582C
B583
B584
B584A
B585
B586
B587
B582A
B588
B807
B801
B702G B702F B702E B702D
B069C
B618
B833A
B618A
B805C
B632B
B632A
B618C
B618B
B005A
B102
B079A
B526
B526A
B524A
B524A
B503A
10 9
BLDG. 17
AIR CONDITIONING
LAB
COLD ROOM G.C. LAB
STORAGE
LAB
STORAGE
TLT
LOCKERS
RESEARCH
LAB
PLMONARY STORRESEARCH
LAB
OFFICE
BIOMED
BIO MED SHOP/OFFICE
STORAGE
LINEN CHUTE
PLUMBING
SHOP
EMS
EQUIPMENT
STORAGE
WELDING
SHOP
MECHANICAL
HVAC
ELECTRICAL
STORAGE
TELEPHONE
SWITCH
ROOM
OFFICE
PHARMACY STORAGE
STORAGE
WATER
METER
MORGUE
STOR
MORGUE
MECHTLT
COMPRESSED GAS
LINEN CHUTE
JAN
RECEIVING
AREA
OFFICE
WAREHOUSE
STORAGE
STORAGE
PLUMBING
STORAGE
PAINT
ELEVATOR
PIT
MENS TOILET
WOMENS TOILET
MECHANICAL
STORAGE
TRAINING ROOM
CARPENTER SHOP
STOR
OFFICE
EMS OFFICE
OFFICE
STORAGE
HVAC
ELECT
MECHANICAL
OFFICES OFFICE
OFFICE
OFFICE OFFICE
TELECOM
OFFICE D
ELECTRIC
JAN
LOCKER
CLOTHING
ROOM
LINEN
SUPPLY
PHARMACY
OFFICE
STOR
BREAK
IT
VAULT
OFFICE
ELEC
OFFICE
OFFICEOFFICE
OFFICE
OFFICE OFFICE OFFICE
OFFICEOFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICES
OFFICE
OFFICE
CANTEEN
STORAGE
OFFICES
STOR
STORAGE
OFFICE
OFFICE
A/C OPERATORS
EMS
STORAGE
OFFICE
MAIL RM/ COPY
CENTER
MECHANICAL
SPACE
STOR
STOR
BIO HAZZARD/ INFECT
WASTE
MENS
CANTEEN
STORAGELOCK
SHOPREFRESHMENT SHOP
PULMONARY
RESEARCH
OFFICE
STOR
BIOMED SHRED
ROOM
PULMONARY
RESEARCH
LAB
PULMONARY
RESEARCH
LAB
PULMONARY
RESEARCH
LAB
OFFICE
BREAK RM
OFFICE
POLICE SUITE
HOLDING
TRAINING RM
DISPATCH
LOCKERS
ARMORY
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE OFFICE
OFFICE/CUBICLES
STORAGE
RADIO
ACTIVE
MATERIALS
OFFICE
OFFICE
OFFICES
OFFICEOFFICE
OFFICE
VOLUNTEER
SERVICES
OFFICE
OFFICE
PIV
OFFICE
OFFICE
VOLUNTEER
ESCORT
RM
STORAGE
STORAGE
EMS SHOP
OFFICE
CONF RM
ELEVATOR
ELEVATOR
ELEVATOR
ELEVATOR
ELEVATOR
ELEVATOR ELEVATOR
ELEVATOR
ELEVATOR ELEVATOR
ELEVATOR
STAIR
STAIR
STAIR
OPC STAIR
STAIR
STAIR
STAIR
STAIR STAIR
STAIR
OFFICE
STOR
OFFICE
OFFICE
IV RMIV RMIV RM BREAK RM
JANITOR
OFFICE
OFFICE
O.R. CHARGING
STATION
EMS
ELECTRICAL
ANTEROOM
STOR
STOR
ELECTRICAL
SUPPLY RM
WOMENS
OFFICE
DECONTAMINATION
SCOPE
PROCESSING
SCOPE
SCOPEPROCESSING
ANTEROOM
OXIDE
NITROUS
STOR
STOR
ELEVATOR LOBBY
ELEVATOR LOBBY
ELEVATOR
LOBBY
AUTOVALET
UP
UP
UP
UP
UP
UP
UP
DN
UP
UP
UP
BLOCKED
DOOR
BLOCKED
DOOR
8' OVERHEAD DOOR
8' OVERHEAD DOOR 8' OVERHEAD DOOR 8' OVERHEAD DOOR
8' OVERHEAD DOOR8' OVERHEAD DOOR
' O
V E
R H
E A
D D
O O
R
4'8" OVERHEAD DOOR
B501
B502
B721
B818A
B723
OFFICE
SERVER RM
SERVER RM
B590
B577
B556B
B556
B556A B551A
B551 B545
B514
B542
B540
B537
B533AA
B533A
B533
B522
B504 B500
A101
#1
#2
BLDG. 19
B589 B024
B505 B505A
B503
B024A
B024AA
B024E
B024C
B024D B024F
B025
B009A
B009
B003
B005
B119 B119A
B111
B094
B090
B079
B070
B030
B036
B039
B040
B030A
B069A
B046B049B051
B064
B054
B069B
B069 B075
#3
#4
#5
B508 B506
B556D
B556C
B103
#7 #8
B514A
B535
B540A
B535A
B522A
B629B B629A
B629C B629D
B612 B610
B702
B617 B615 B613 B607 B605
B601
B632
B700
B630
B624
B714
B802
B710
B717
B712
B719 B804
B834 B836
B833 B835
B818
B816
B716
B726
B724
B821 B821A
B821B
B821D B821C
B808
B806
B813
B803
B805
B805A
B705
B805B
B703
B701
B830
B832
B609
B818B
B802A
B801
B614
B601A
B611
B702B
B629
B702
B702C
B626
B628
B837
B556E
B556F
B113
B001
B700A
B002
B020
B080B530
B579
B700B
B815
B728
B622
B007
B707B708
B095
B588A
B580 B581
B582
B582B
B582C
B583
B584
B584A
B585
B586
B587
B582A
B588
B807
B801
B702G B702F B702E B702D
B069C
B618
B833A
B618A
B805C
B632B
B632A
B618C
B618B
B005A
B102
B079A
B526
B526A
B524A
B524A
B503A
10 9
BLDG. 17
AIR CONDITIONING
LAB
COLD ROOM G.C. LAB
STORAGE
LAB
STORAGE
TLT
LOCKERS
RESEARCH
LAB
PLMONARY STORRESEARCH
LAB
OFFICE
BIOMED
BIO MED SHOP/OFFICE
STORAGE
LINEN CHUTE
PLUMBING
SHOP
EMS
EQUIPMENT
STORAGE
WELDING
SHOP
MECHANICAL
HVAC
ELECTRICAL
STORAGE
TELEPHONE
SWITCH
ROOM
OFFICE
PHARMACY STORAGE
STORAGE
WATER
METER
MORGUE
STOR
MORGUE
MECHTLT
COMPRESSED GAS
LINEN CHUTE
JAN
RECEIVING
AREA
OFFICE
WAREHOUSE
STORAGE
STORAGE
PLUMBING
STORAGE
PAINT
ELEVATOR
PIT
MENS TOILET
WOMENS TOILET
MECHANICAL
STORAGE
TRAINING ROOM
CARPENTER SHOP
STOR
OFFICE
EMS OFFICE
OFFICE
STORAGE
HVAC
ELECT
MECHANICAL
OFFICES OFFICE
OFFICE
OFFICE OFFICE
TELECOM
OFFICE D
ELECTRIC
JAN
LOCKER
CLOTHING
ROOM
LINEN
SUPPLY
PHARMACY
OFFICE
STOR
BREAK
IT
VAULT
OFFICE
ELEC
OFFICE
OFFICEOFFICE
OFFICE
OFFICE OFFICE OFFICE
OFFICEOFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICES
OFFICE
OFFICE
CANTEEN
STORAGE
OFFICES
STOR
STORAGE
OFFICE
OFFICE
A/C OPERATORS
EMS
STORAGE
OFFICE
MAIL RM/ COPY
CENTER
MECHANICAL
SPACE
STOR
STOR
BIO HAZZARD/ INFECT
WASTE
MENS
CANTEEN
STORAGELOCK
SHOPREFRESHMENT SHOP
PULMONARY
RESEARCH
OFFICE
STOR
BIOMED SHRED
ROOM
PULMONARY
RESEARCH
LAB
PULMONARY
RESEARCH
LAB
PULMONARY
RESEARCH
LAB
OFFICE
BREAK RM
OFFICE
POLICE SUITE
HOLDING
TRAINING RM
DISPATCH
LOCKERS
ARMORY
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE OFFICE
OFFICE/CUBICLES
STORAGE
RADIO
ACTIVE
MATERIALS
OFFICE
OFFICE
OFFICES
OFFICEOFFICE
OFFICE
VOLUNTEER
SERVICES
OFFICE
OFFICE
PIV
OFFICE
OFFICE
VOLUNTEER
ESCORT
RM
STORAGE
STORAGE
EMS SHOP
OFFICE
CONF RM
ELEVATOR
ELEVATOR
ELEVATOR
ELEVATOR
ELEVATOR
ELEVATOR ELEVATOR
ELEVATOR
ELEVATOR ELEVATOR
ELEVATOR
STAIR
STAIR
STAIR
OPC STAIR
STAIR
STAIR
STAIR
STAIR STAIR
STAIR
OFFICE
STOR
OFFICE
OFFICE
IV RMIV RMIV RM BREAK RM
JANITOR
OFFICE
OFFICE
O.R. CHARGING
STATION
EMS
ELECTRICAL
ANTEROOM
STOR
STOR
ELECTRICAL
SUPPLY RM
WOMENS
OFFICE
DECONTAMINATION
SCOPE
PROCESSING
SCOPE
SCOPEPROCESSING
ANTEROOM
OXIDE
NITROUS
STOR
STOR
ELEVATOR LOBBY
ELEVATOR LOBBY
ELEVATOR
LOBBY
AUTOVALET
UP
UP
UP
UP
UP
UP
UP
DN
UP
UP
UP
BLOCKED
DOOR
BLOCKED
DOOR
8' OVERHEAD DOOR
8' OVERHEAD DOOR 8' OVERHEAD DOOR 8' OVERHEAD DOOR
8' OVERHEAD DOOR8' OVERHEAD DOOR
' O
V E
R H
E A
D D
O O
R
4'8" OVERHEAD DOOR
B501
B502
B721
B818A
B723
OFFICE
SERVER RM
SERVER RM
B590
B577
B556B
B556
B556A B551A
B551 B545
B514
B542
B540
B537
B533AA
B533A
B533
B522
B504 B500
A101
#1
#2
BLDG. 19
B589 B024
B505 B505A
B503
B024A
B024AA
B024E
B024C
B024D B024F
B025
B009A
B009
B003
B005
B119 B119A
B111
B094
B090
B079
B070
B030
B036
B039
B040
B030A
B069A
B046B049B051
B064
B054
B069B
B069 B075
#3
#4
#5
B508 B506
B556D
B556C
B103
#7 #8
B514A
B535
B540A
B535A
B522A
B629B B629A
B629C B629D
B612 B610
B702
B617 B615 B613 B607 B605
B601
B632
B700
B630
B624
B714
B802
B710
B717
B712
B719 B804
B834 B836
B833 B835
B818
B816
B716
B726
B724
B821 B821A
B821B
B821D B821C
B808
B806
B813
B803
B805
B805A
B705
B805B
B703
B701
B830
B832
B609
B818B
B802A
B801
B614
B601A
B611
B702B
B629
B702
B702C
B626
B628
B837
B556E
B556F
B113
B001
B700A
B002
B020
B080B530
B579
B700B
B815
B728
B622
B007
B707B708
B095
B588A
B580 B581
B582
B582B
B582C
B583
B584
B584A
B585
B586
B587
B582A
B588
B807
B801
B702G B702F B702E B702D
B069C
B618
B833A
B618A
B805C
B632B
B632A
B618C
B618B
B005A
B102
B079A
B526
B526A
B524A
B524A
B503A
10 9
BLDG. 17
AIR CONDITIONING
LAB
COLD ROOM G.C. LAB
STORAGE
LAB
STORAGE
TLT
LOCKERS
RESEARCH
LAB
PLMONARY STORRESEARCH
LAB
OFFICE
BIOMED
BIO MED SHOP/OFFICE
STORAGE
LINEN CHUTE
PLUMBING
SHOP
EMS
EQUIPMENT
STORAGE
WELDING
SHOP
MECHANICAL
HVAC
ELECTRICAL
STORAGE
TELEPHONE
SWITCH
ROOM
OFFICE
PHARMACY STORAGE
STORAGE
WATER
METER
MORGUE
STOR
MORGUE
MECHTLT
COMPRESSED GAS
LINEN CHUTE
JAN
RECEIVING
AREA
OFFICE
WAREHOUSE
STORAGE
STORAGE
PLUMBING
STORAGE
PAINT
ELEVATOR
PIT
MENS TOILET
WOMENS TOILET
MECHANICAL
STORAGE
TRAINING ROOM
CARPENTER SHOP
STOR
OFFICE
EMS OFFICE
OFFICE
STORAGE
HVAC
ELECT
MECHANICAL
OFFICES OFFICE
OFFICE
OFFICE OFFICE
TELECOM
OFFICE D
ELECTRIC
JAN
LOCKER
CLOTHING
ROOM
LINEN
SUPPLY
PHARMACY
OFFICE
STOR
BREAK
IT
VAULT
OFFICE
ELEC
OFFICE
OFFICEOFFICE
OFFICE
OFFICE OFFICE OFFICE
OFFICEOFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICES
OFFICE
OFFICE
CANTEEN
STORAGE
OFFICES
STOR
STORAGE
OFFICE
OFFICE
A/C OPERATORS
EMS
STORAGE
OFFICE
MAIL RM/ COPY
CENTER
MECHANICAL
SPACE
STOR
STOR
BIO HAZZARD/ INFECT
WASTE
MENS
CANTEEN
STORAGELOCK
SHOPREFRESHMENT SHOP
PULMONARY
RESEARCH
OFFICE
STOR
BIOMED SHRED
ROOM
PULMONARY
RESEARCH
LAB
PULMONARY
RESEARCH
LAB
PULMONARY
RESEARCH
LAB
OFFICE
BREAK RM
OFFICE
POLICE SUITE
HOLDING
TRAINING RM
DISPATCH
LOCKERS
ARMORY
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE OFFICE
OFFICE/CUBICLES
STORAGE
RADIO
ACTIVE
MATERIALS
OFFICE
OFFICE
OFFICES
OFFICEOFFICE
OFFICE
VOLUNTEER
SERVICES
OFFICE
OFFICE
PIV
OFFICE
OFFICE
VOLUNTEER
ESCORT
RM
STORAGE
STORAGE
EMS SHOP
OFFICE
CONF RM
ELEVATOR
ELEVATOR
ELEVATOR
ELEVATOR
ELEVATOR
ELEVATOR ELEVATOR
ELEVATOR
ELEVATOR ELEVATOR
ELEVATOR
STAIR
STAIR
STAIR
OPC STAIR
STAIR
STAIR
STAIR
STAIR STAIR
STAIR
OFFICE
STOR
OFFICE
OFFICE
IV RMIV RMIV RM BREAK RM
JANITOR
OFFICE
OFFICE
O.R. CHARGING
STATION
EMS
ELECTRICAL
ANTEROOM
STOR
STOR
ELECTRICAL
SUPPLY RM
WOMENS
OFFICE
DECONTAMINATION
SCOPE
PROCESSING
SCOPE
SCOPEPROCESSING
ANTEROOM
OXIDE
NITROUS
STOR
STOR
ELEVATOR LOBBY
ELEVATOR LOBBY
ELEVATOR
LOBBY
AUTOVALET
UP
UP
UP
UP
UP
UP
UP
DN
UP
UP
UP
BLOCKED
DOOR
BLOCKED
DOOR
8' OVERHEAD DOOR
8' OVERHEAD DOOR 8' OVERHEAD DOOR 8' OVERHEAD DOOR
8' OVERHEAD DOOR8' OVERHEAD DOOR
' O
V E
R H
E A
D D
O O
R
4'8" OVERHEAD DOOR
SD
V F
D V
F D
V F
D V
F D
1. REFER TO SHEET E-001 FOR ELECTRICAL DEMOLITION NOTES.
2. ALL HALFTONE EQUIPMENT SHOWN IS EXISTING TO REMAIN. DASHED OR FULL
TONE EQUIPMENT IS TO BE DEMOLISHED.
3. DEMO KEYED NOTES AND THEIR CORRESPONDING NUMBERS ARE TYPICAL FOR
ALL ELECTRICAL DEMOLITION SHEETS. NOT ALL KEYED NOTES ARE USED ON
EACH SHEET.
01-ED100
01-ED100
01-ED100
01-ED100
01-ED100
TELECOMMUNICATIONS
RM.
B721
TELECOMMUNICATIONS
RM.
B024C
OFFICE
B024D
ETA
ETB
PTP
TELECOMMUNICATIONS
RM.
B611
TELECOMMUNICATIONS
RM.
B818A
BIOMED OFFICE
B717
ET-1 (EX)
ET-2 (EX)
TCT1944 (EX) TCT1909 (EX)
TNM1901 (EX)
EP3 (EX)
200A
(EX)
200A
(EX)
400A
(EX)
400A
(EX)
BP
BP
(EX)AIR COMPRESSOR
SHALL BE RELOCATED.
(EX)EXPANSION TANKS
SHALL BE RELOCATED.
(EX)GLYCOL FILL TANK
SHALL BE RELCOATED.
(EX)GLYCOL PUMP
(EX)STEAM TO HW
HEAT EXCHANGER
(EX)STEAM PRV
(EX)STEAM TO HW
HEAT EXCHANGER
(EX)STEAM TO HW
HEAT EXCHANGER
(EX)STEAM TO HW
HEAT EXCHANGER
(EX)GLYCOL PUMP (EX)GLYCOL PUMP
(EX)GLYCOL PUMP
(EX)AIR COMPRESSOR
SHALL BE RELOCATED.
(EX)
(EX)
(EX)
G ra p h ic S ca le
/1 6"
0"
G ra p h ic S ca le
/1 6"
0"
G ra p h ic S ca le
/8
0"
G ra p h ic S ca le
/3 2"
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
/8
0"
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
1' -0
G ra p h ic S ca le
/2
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
NOT FOR
PERMITTING OR
CONSTRUCTION
A/E:Consultant:
Approved: Spinklered
Office of Construction and Facilities Management FULLY SPRINKLERED
B
IM
/V
IS
N
O m a h a
E H
R M
/O m a h a
E H
R M
V
.r vt
/1
/2
:0
:4
P
M
YW PPMAY 15, 2023
01-ED100
636 - OMAHA VA MEDICAL CENTER
ISSUE FOR BIDBUILDING 01 - LEVEL 00 ELECTRICAL
DEMOLITION PLAN
636-21-704OMAHA EHRM INFRASTRUCTURE
UPGRADE DESIGN
3/64" = 1'-0"1
BLDG. 01 - LEVEL 00 ELECTRICAL DEMOLITION PLAN
1/4" = 1'-0"3
BLDG. 01 - RM. B721,B723 ELECTRICAL DEMO PLAN
1/4" = 1'-0"
BLDG. 01 - RM. B024C ELECTRICAL DEMO PLAN
1/4" = 1'-0"5
BLDG. 01 - RM. B611 ELECTRICAL DEMO PLAN
1/4" = 1'-0"6
BLDG. 01 - RM. B818A ELECTRICAL DEMO PLAN
1/4" = 1'-0"2
BLDG. 01 - RM. B714,B717 ELECTRICAL DEMO PLAN
1 EXISTING PANEL TO REMAIN.
2 DISCONNECT AND REMOVE PANEL FOR RELOCATION.
3 EXISTING PANELS TO BE DISCONNECT AND REMOVED. DISCONNECT AND REMOVE
UPS AND TURN OVER TO THE OWNER.
4 DISCONNECT AND REMOVE POWER AND PULLBOX.
5 DISCONNECT AND REMOVE POWER AND OUTLET.
6 EXISTING MECHANICAL EQUIPMENT TO REMAIN. DISCONNECT TO BE REPLACED.
REFER TO SHEET 01-EP100 FOR ADDITIONAL REQUIREMENTS.
7 DISCONNECT AND REMOVE PANEL FOR REPLACEMENT. INCOMING FEEDERS TO
REMAIN.
8 EXISTING MECHANICAL EQUIPMENT TO BE REMOVED. DISCONNECT AND REMOVE
ELECTRICAL DISCONNECT BACK TO SERVING PANEL.
9 EXISTING LIGHT SWITCH TO REMAIN.
10 (4) 4" CONDUITS ON CEILING TO REMAIN.
11 DISCONNECT AND REMOVE DISCONNECT SWITCH FOR RELOCATION. SEE SHEET
01-EP-101 FOR NEW LOCATION.
12 CEILING MOUNTED PULLBOX AND CONDUITS TO REMAIN.
13 UNISTRUT MOUNTED RECEPTACLE TO BE DISCONNECTED AND RELOCATED. SEE
SHEET 01-EP101 FOR NEW LOCATION.
14 GENERATOR CONTRACTOR SHALL REMOVE ALL ABANDONED MECHANICAL
EQUIPMENT, SHELVING, AND OTHER ITEMS AS DIRECTED BY VA.
1 EXISTING PANEL TO REMAIN.
2 DISCONNECT AND REMOVE PANEL FOR RELOCATION.
3 EXISTING PANELS TO BE DISCONNECT AND REMOVED. DISCONNECT AND REMOVE
UPS AND TURN OVER TO THE OWNER.
4 DISCONNECT AND REMOVE POWER AND PULLBOX.
5 DISCONNECT AND REMOVE POWER AND OUTLET.
6 EXISTING MECHANICAL EQUIPMENT TO REMAIN. DISCONNECT TO BE REPLACED.
REFER TO SHEET 01-EP100 FOR ADDITIONAL REQUIREMENTS.
7 DISCONNECT AND REMOVE PANEL FOR REPLACEMENT. INCOMING FEEDERS TO
REMAIN.
8 EXISTING MECHANICAL EQUIPMENT TO BE REMOVED. DISCONNECT AND REMOVE
ELECTRICAL DISCONNECT BACK TO SERVING PANEL.
9 EXISTING LIGHT SWITCH TO REMAIN.
10 (4) 4" CONDUITS ON CEILING TO REMAIN.
11 DISCONNECT AND REMOVE DISCONNECT SWITCH FOR RELOCATION. SEE SHEET
01-EP-101 FOR NEW LOCATION.
12 CEILING MOUNTED PULLBOX AND CONDUITS TO REMAIN.
13 UNISTRUT MOUNTED RECEPTACLE TO BE DISCONNECTED AND RELOCATED. SEE
SHEET 01-EP101 FOR NEW LOCATION.
14 GENERATOR CONTRACTOR SHALL REMOVE ALL ABANDONED MECHANICAL
EQUIPMENT, SHELVING, AND OTHER ITEMS AS DIRECTED BY VA.
Revisions: Date:
1/4" = 1'-0"4
BLDG. 01 - RM. B830 - ELECTRICAL DEMO PLAN
NOT FOR
TELECOM
#19
IT
1205B
HAC STORAGE
EXIT TO OUTSIDE
EXIT TO OUTSIDE
EXIT TO OUTSIDE
EXIT TO OUTSIDE
EXIT TO OUTSIDE
EXIT TO OUTSIDE
EXIT TO OUTSIDE
EXIT TO OUTSIDE
EXIT TO OUTSIDE EXIT TO OUTSIDE
EXIT TO OUTSIDE
EXIT TO OUTSIDE
EXIT TO
OUTSIDE
EXIT TO
OUTSIDE
EXIT TO
OUTSIDE
EXIT
EXIT
EXIT
EXIT
EXIT
stretcher crash cart
C A
B
IN
E T
B Y
P H
IL
IP
S
IN
C
C A
B
IN
E T
B Y
P H
IL
IP
S
IN
C
L C
C (N
IC
R M
M U
(N
IC
P V
(N
IC
R F
A C
(N
IC
D
A C
(N
IC
G A
C (N
IC
IM
D
U (N
IC
P D
U (N
IC
) C B
(N
IC
A E
C (N
IC
S C
(N
IC
PNEUM TUBE STATION
EYE WASH STATION
BLDG 17
PNEUM TUBE STATION
ENTRY FOR PHARMACY
AUDIOLOGY
DN
O H DOOR
O H DOOR
UP
DN
DN
DN
UP
DN
UP
DN
UP
DN
DN
UP
UP
DN
DN
UP
DN
ELECTRICAL
POWER
DISTRIBUTION
EMERGENCY
GENERATORS
TOILETBREAK RM
#3
#2
#1
#7 #12
MEDS
#18
#11
JAN
#6
#17
SUPPLY
STORAGE
#5
#4
#8
#9
#10
#16
#15
#14
#13 #20
#21
#22
#23
SUPPLY RM
#24
#29 #33
#28
#27
#32
STORAGE
OFFICES
#34
SOILED
INTAKE
#31
#30
#26
#25
WAITING
WAITING
ELECTRICAL
MALE
OFFICE
OFFICE
OFFICE
#1
#2
#6 EXAM EXAM
#10 #11 #12
#13 #14 #15
#16 #17 #18
UTIL
#3
OFFICE
TOILET
WAITING
EYEWASH
SHOWER/
CORRIDOR
TEAM CENTER
OFFICE
NURSE STATION
NURSE STATION
SEATING
EXAM-C EXAM-B EXAM-A
EXAM-7
EXAM-8
EXAM-9
EXAM-10
RECEPTION
SUPPLY RM TOILET
EXAM-3EXAM-2EXAM-1
EXAM-4EXAM-5EXAM-6
BREAK RM
WORK RM
SLEEP RM
CLST
OFFICE
EXAM-18
STAFF LUNCH RM
EXAM-16
EXAM-15
EXAM-14
EXAM-10EXAM-7
EXAM-8 EXAM-11
OFFICE
OFFICE
EXAM-9 EXAM-12
EXAM-19
EXAM-5
EXAM-4
EXAM-3
EXAM-2
EXAM-1 CONSULT CHECK
IN/OUT
EXAM-6
WORK RM
WORK RMEXAM-20
OFFICE
EXAM-21
EXAM-22
EXAM-23
AGENT
CASHIER
CHECK IN
LAB
STORAGE
WOMENS
TOILET
PUBLIC
TOILET
DRAW
DRAW
DRAW
DRAW
DRAW
DRAW
FAMILY
TOILET
OFFICE
CARE
COORD
TOILET
RECEPTION
OFFICE
TRANSITIONAL
CARE
ITELECTRICAL
#34
MRI VESTIBULE
MECH
DRESSING
EQUIPMENT
MRI
WORK RM
CORRIDOR
IN TAKE
IN TAKE
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
STORAGE
STAIR
STAIR
TOILET
FEMALE
TOILET
CORRIDOR
VACANT
MRI STORAGE
MRI EQUIPMENT RM
MRI
CONTROL RM
WORK AREA
LOCKER
DIRTY UTILITY
TOILETTOILET
RM
DRESSING
RM
DRESSING
CHECK IN
OFFICE
OFFICE
CORRIDOR
CORRIDOR
CORRIDOR
PHARMACIST
OFFICE
OFFICETELE RETINAL
AND EYE TECH
OFFICE
EXAM
STORAGE STORAGE
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
RESTROOM
STAFF
CORRIDOR
PUMP RM
CORRIDOR
STAIR
CORRIDOR
CORRIDOR CORRIDOR
WORK RM
EXAM-15 EXAM-6
EXAM-7
EXAM-8
EXAM-13
EXAM-12
EXAM-11
EXAM-10
EXAM-9
EXAM-3
EXAM-4
EXAM-5
EXAM-2
WORK RM
LOBBY
VASCULAR
LAB
VASCULAR
LAB
HAC
N S
WAITING OFFICE OFFICE OFFICE OFFICE
OFFICE
OFFICE
MECH
HVACELECTRICAL
DISTRIBUTION
EDUCATION
CONFERENCE
RM
STORAGE STORAGE
LOUNGE
TOILET
WAITING
INTERVIEW
TOILET
OFFICE
OFFICE
EXAM RM
TELCOM
OVER
HEAD
AUDIO
SUPPLY
MECH
OFFICE
CONFERENCE RM
TOILET
VAULT
PHARMACY
OFFICE
CONSULT
COMPOUND
AUDIOLOGYAUDIOLOGY
BREAK RM
NURSE STATION
CLERICAL/
BUSINESS
INFORMATION
COFFEE
LOBBY
UNISEX
TOILET
PERC
TELEPHONE
SWITCH BOARD
MENS
TOILET
OFFICE
OFFICE
SOUND
BOOTH
WAITING
OFFICE
EXAM
EXAM
EXAM
EXAM
OFFICE
OPTHAMOLOGY RM-10
OPTHAMOLOGY RM-9
OPTHAMOLOGY RM-8
OPTHAMOLOGY RM-1
OPTHAMOLOGY RM-2
OPTHAMOLOGY RM-3
OPTHAMOLOGY RM-4
OPHTHALMOLOGY RM-6
OPTHAMOLOGY RM-5
OPTHAMOLOGY
LASER RM
VASCULAR
PROC
CHECK IN
EXAM RM
WORKEXAM RM
EXAM RM
EXAM RM
OFFICE
INTERVIEW
OFFICE
TRIAGE
WAITING RM
OFFICE
WAITING
OFFICE
TOILETTOILET
DIRTY UTILITY
CLEAN UTILITY
OFFICE
POLICE
TOILET
ELEVATOR LOBBY
OFFICE
STAIR
HAC
CORRIDOR
CORRIDOR
CORRIDOR
STAIR
ELECTRICAL
CORRIDOR
CORRIDOR
ELEVATOR ELEVATOR
SPRINKLER
CONTROL VALVE
MENS
WAITING
OPTHAMOLOGY RM-7
STAIR
CORRIDOR
CORRIDOR
RESTROOM
WOMEN
CORRIDOR
RECEPTION
ELEVATOR
ELEVATOR ELEVATOR
ELEVATOR
ELEVATOR
CORRIDOR
TOILET
STAIR
HAC
STORAGE
ELEVATOR ELEVATOR
SWITCH
COUNTER RM
MECH
OFFICE
UNISEX
TOILET
MALE
TOILET
BREAK RM
ELECTRICAL
OFFICE
TOILET
ELEVATOR
OFFICE
OFFICE OFFICE
STORAGE
JAN
CONFERENCE
OFFICE
CHAPEL
PRAYER
RM
OFFICE CHECK IN OFFICE OFFICE
OFFICE
LAB
EXAM
EXAM
EXAM
EXAM EXAM
EXAM
STORAGE
EXAM
EXAM
LAB
EXAM
STAFF LOUNGE
R.R.
CORRIDOR
OFFICE
CORRIDOR
LOCKER
STOR
STAIR
TOILET
EXAM
CORRIDOR
1269A
1788B
1738A
1711A
1711B
1655A
165316521651
164916481647
164516441643
164016391638
16581660
1434 1430
1436 1428
1442 1422
1446a
14521453
1450a
1615C
1505A
1432A
1620A
1519 1520
1508B
1352 1354 1356
1369 1368
137313721371
137413751376
1383A
M101
C1653B
C1418C1418
C1418
C1418
C235B
C295
C295
C255
C255C255C255
C250 C250 C250C250
C250
C245
C245
C245
C240
C205B C205A
1788A
1636A
1506A
1206A
1310 1300D
1300C
1300B
1300A1300E
1000A
13051315
1205A
1265 1257 1255
1230 1231
1207 1205 1203 1201 1101
1317A
1105B
1105C 1105D
1001A1001E
1001B
1103 1113
1103A
1115A
1105A
S1
1110 1114
1012A 1012B
1012C
1104A
1104B
1000B
13181320
1330A
1330B
1330C
1385A
1385B 13841382
1366A
1050A
C260
C1104
C1104
C104
C210A
C235A
C265B
C265
C235
C220
C215
C210
C210
C210
C205 C205
C200
C260B
9 10
1 3
1200A
7 8
1001C
1140A
1025A
1053A 1053B 1053C 1053D
1053E
1053G
1053F
1138 1140
1143114111391137113511311129
A # 6
1167A
1163A
C260A
C265A
1053H
TELECOM
#19
IT
1205B
HAC STORAGE
EXIT TO OUTSIDE
EXIT TO OUTSIDE
EXIT TO OUTSIDE
EXIT TO OUTSIDE
EXIT TO OUTSIDE
EXIT TO OUTSIDE
EXIT TO OUTSIDE
EXIT TO OUTSIDE
EXIT TO OUTSIDE EXIT TO OUTSIDE
EXIT TO OUTSIDE
EXIT TO OUTSIDE
EXIT TO
OUTSIDE
EXIT TO
OUTSIDE
EXIT TO
OUTSIDE
EXIT
EXIT
EXIT
EXIT
EXIT
stretcher crash cart
C A
B
IN
E T
B Y
P H
IL
IP
S
IN
C
C A
B
IN
E T
B Y
P H
IL
IP
S
IN
C
L C
C (N
IC
R M
M U
(N
IC
P V
(N
IC
R F
A C
(N
IC
D
A C
(N
IC
G A
C (N
IC
IM
D
U (N
IC
P D
U (N
IC
) C B
(N
IC
A E
C (N
IC
S C
(N
IC
PNEUM TUBE STATION
EYE WASH STATION
BLDG 17
PNEUM TUBE STATION
ENTRY FOR PHARMACY
AUDIOLOGY
DN
O H DOOR
O H DOOR
UP
DN
DN
DN
UP
DN
UP
DN
UP
DN
DN
UP
UP
DN
DN
UP
DN
ELECTRICAL
POWER
DISTRIBUTION
EMERGENCY
GENERATORS
TOILETBREAK RM
#3
#2
#1
#7 #12
MEDS
#18
#11
JAN
#6
#17
SUPPLY
STORAGE
#5
#4
#8
#9
#10
#16
#15
#14
#13 #20
#21
#22
#23
SUPPLY RM
#24
#29 #33
#28
#27
#32
STORAGE
OFFICES
#34
SOILED
INTAKE
#31
#30
#26
#25
WAITING
WAITING
ELECTRICAL
MALE
OFFICE
OFFICE
OFFICE
#1
#2
#6 EXAM EXAM
#10 #11 #12
#13 #14 #15
#16 #17 #18
UTIL
#3
OFFICE
TOILET
WAITING
EYEWASH
SHOWER/
CORRIDOR
TEAM CENTER
OFFICE
NURSE STATION
NURSE STATION
SEATING
EXAM-C EXAM-B EXAM-A
EXAM-7
EXAM-8
EXAM-9
EXAM-10
RECEPTION
SUPPLY RM TOILET
EXAM-3EXAM-2EXAM-1
EXAM-4EXAM-5EXAM-6
BREAK RM
WORK RM
SLEEP RM
CLST
OFFICE
EXAM-18
STAFF LUNCH RM
EXAM-16
EXAM-15
EXAM-14
EXAM-10EXAM-7
EXAM-8 EXAM-11
OFFICE
OFFICE
EXAM-9 EXAM-12
EXAM-19
EXAM-5
EXAM-4
EXAM-3
EXAM-2
EXAM-1 CONSULT CHECK
IN/OUT
EXAM-6
WORK RM
WORK RMEXAM-20
OFFICE
EXAM-21
EXAM-22
EXAM-23
AGENT
CASHIER
CHECK IN
LAB
STORAGE
WOMENS
TOILET
PUBLIC
TOILET
DRAW
DRAW
DRAW
DRAW
DRAW
DRAW
FAMILY
TOILET
OFFICE
CARE
COORD
TOILET
RECEPTION
OFFICE
TRANSITIONAL
CARE
ITELECTRICAL
#34
MRI VESTIBULE
MECH
DRESSING
EQUIPMENT
MRI
WORK RM
CORRIDOR
IN TAKE
IN TAKE
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
STORAGE
STAIR
STAIR
TOILET
FEMALE
TOILET
CORRIDOR
VACANT
MRI STORAGE
MRI EQUIPMENT RM
MRI
CONTROL RM
WORK AREA
LOCKER
DIRTY UTILITY
TOILETTOILET
RM
DRESSING
RM
DRESSING
CHECK IN
OFFICE
OFFICE
CORRIDOR
CORRIDOR
CORRIDOR
PHARMACIST
OFFICE
OFFICETELE RETINAL
AND EYE TECH
OFFICE
EXAM
STORAGE STORAGE
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
RESTROOM
STAFF
CORRIDOR
PUMP RM
CORRIDOR
STAIR
CORRIDOR
CORRIDOR CORRIDOR
WORK RM
EXAM-15 EXAM-6
EXAM-7
EXAM-8
EXAM-13
EXAM-12
EXAM-11
EXAM-10
EXAM-9
EXAM-3
EXAM-4
EXAM-5
EXAM-2
WORK RM
LOBBY
VASCULAR
LAB
VASCULAR
LAB
HAC
N S
WAITING OFFICE OFFICE OFFICE OFFICE
OFFICE
OFFICE
MECH
HVACELECTRICAL
DISTRIBUTION
EDUCATION
CONFERENCE
RM
STORAGE STORAGE
LOUNGE
TOILET
WAITING
INTERVIEW
TOILET
OFFICE
OFFICE
EXAM RM
TELCOM
OVER
HEAD
AUDIO
SUPPLY
MECH
OFFICE
CONFERENCE RM
TOILET
VAULT
PHARMACY
OFFICE
CONSULT
COMPOUND
AUDIOLOGYAUDIOLOGY
BREAK RM
NURSE STATION
CLERICAL/
BUSINESS
INFORMATION
COFFEE
LOBBY
UNISEX
TOILET
PERC
TELEPHONE
SWITCH BOARD
MENS
TOILET
OFFICE
OFFICE
SOUND
BOOTH
WAITING
OFFICE
EXAM
EXAM
EXAM
EXAM
OFFICE
OPTHAMOLOGY RM-10
OPTHAMOLOGY RM-9
OPTHAMOLOGY RM-8
OPTHAMOLOGY RM-1
OPTHAMOLOGY RM-2
OPTHAMOLOGY RM-3
OPTHAMOLOGY RM-4
OPHTHALMOLOGY RM-6
OPTHAMOLOGY RM-5
OPTHAMOLOGY
LASER RM
VASCULAR
PROC
CHECK IN
EXAM RM
WORKEXAM RM
EXAM RM
EXAM RM
OFFICE
INTERVIEW
OFFICE
TRIAGE
WAITING RM
OFFICE
WAITING
OFFICE
TOILETTOILET
DIRTY UTILITY
CLEAN UTILITY
OFFICE
POLICE
TOILET
ELEVATOR LOBBY
OFFICE
STAIR
HAC
CORRIDOR
CORRIDOR
CORRIDOR
STAIR
ELECTRICAL
CORRIDOR
CORRIDOR
ELEVATOR ELEVATOR
SPRINKLER
CONTROL VALVE
MENS
WAITING
OPTHAMOLOGY RM-7
STAIR
CORRIDOR
CORRIDOR
RESTROOM
WOMEN
CORRIDOR
RECEPTION
ELEVATOR
ELEVATOR ELEVATOR
ELEVATOR
ELEVATOR
CORRIDOR
TOILET
STAIR
HAC
STORAGE
ELEVATOR ELEVATOR
SWITCH
COUNTER RM
MECH
OFFICE
UNISEX
TOILET
MALE
TOILET
BREAK RM
ELECTRICAL
OFFICE
TOILET
ELEVATOR
OFFICE
OFFICE OFFICE
STORAGE
JAN
CONFERENCE
OFFICE
CHAPEL
PRAYER
RM
OFFICE CHECK IN OFFICE OFFICE
OFFICE
LAB
EXAM
EXAM
EXAM
EXAM EXAM
EXAM
STORAGE
EXAM
EXAM
LAB
EXAM
STAFF LOUNGE
R.R.
CORRIDOR
OFFICE
CORRIDOR
LOCKER
STOR
STAIR
TOILET
EXAM
CORRIDOR
1269A
1788B
1738A
1711A
1711B
1655A
165316521651
164916481647
164516441643
164016391638
16581660
1434 1430
1436 1428
1442 1422
1446a
14521453
1450a
1615C
1505A
1432A
1620A
1519 1520
1508B
1352 1354 1356
1369 1368
137313721371
137413751376
1383A
M101
C1653B
C1418C1418
C1418
C1418
C235B
C295
C295
C255
C255C255C255
C250 C250 C250C250
C250
C245
C245
C245
C240
C205B C205A
1788A
1636A
1506A
1206A
1310 1300D
1300C
1300B
1300A1300E
1000A
13051315
1205A
1265 1257 1255
1230 1231
1207 1205 1203 1201 1101
1317A
1105B
1105C 1105D
1001A1001E
1001B
1103 1113
1103A
1115A
1105A
S1
1110 1114
1012A 1012B
1012C
1104A
1104B
1000B
13181320
1330A
1330B
1330C
1385A
1385B 13841382
1366A
1050A
C260
C1104
C1104
C104
C210A
C235A
C265B
C265
C235
C220
C215
C210
C210
C210
C205 C205
C200
C260B
9 10
1 3
1200A
7 8
1001C
1140A
1025A
1053A 1053B 1053C 1053D
1053E
1053G
1053F
1138 1140
1143114111391137113511311129
A # 6
1167A
1163A
C260A
C265A
1053H
TELECOM
#19
IT
1205B
HAC STORAGE
EXIT TO OUTSIDE
EXIT TO OUTSIDE
EXIT TO OUTSIDE
EXIT TO OUTSIDE
EXIT TO OUTSIDE
EXIT TO OUTSIDE
EXIT TO OUTSIDE
EXIT TO OUTSIDE
EXIT TO OUTSIDE EXIT TO OUTSIDE
EXIT TO OUTSIDE
EXIT TO OUTSIDE
EXIT TO
OUTSIDE
EXIT TO
OUTSIDE
EXIT TO
OUTSIDE
EXIT
EXIT
EXIT
EXIT
EXIT
stretcher crash cart
C A
B
IN
E T
B Y
P H
IL
IP
S
IN
C
C A
B
IN
E T
B Y
P H
IL
IP
S
IN
C
L C
C (N
IC
R M
M U
(N
IC
P V
(N
IC
R F
A C
(N
IC
D
A C
(N
IC
G A
C (N
IC
IM
D
U (N
IC
P D
U (N
IC
) C B
(N
IC
A E
C (N
IC
S C
(N
IC
PNEUM TUBE STATION
EYE WASH STATION
BLDG 17
PNEUM TUBE STATION
ENTRY FOR PHARMACY
AUDIOLOGY
DN
O H DOOR
O H DOOR
UP
DN
DN
DN
UP
DN
UP
DN
UP
DN
DN
UP
UP
DN
DN
UP
DN
ELECTRICAL
POWER
DISTRIBUTION
EMERGENCY
GENERATORS
TOILETBREAK RM
#3
#2
#1
#7 #12
MEDS
#18
#11
JAN
#6
#17
SUPPLY
STORAGE
#5
#4
#8
#9
#10
#16
#15
#14
#13 #20
#21
#22
#23
SUPPLY RM
#24
#29 #33
#28
#27
#32
STORAGE
OFFICES
#34
SOILED
INTAKE
#31
#30
#26
#25
WAITING
WAITING
ELECTRICAL
MALE
OFFICE
OFFICE
OFFICE
#1
#2
#6 EXAM EXAM
#10 #11 #12
#13 #14 #15
#16 #17 #18
UTIL
#3
OFFICE
TOILET
WAITING
EYEWASH
SHOWER/
CORRIDOR
TEAM CENTER
OFFICE
NURSE STATION
NURSE STATION
SEATING
EXAM-C EXAM-B EXAM-A
EXAM-7
EXAM-8
EXAM-9
EXAM-10
RECEPTION
SUPPLY RM TOILET
EXAM-3EXAM-2EXAM-1
EXAM-4EXAM-5EXAM-6
BREAK RM
WORK RM
SLEEP RM
CLST
OFFICE
EXAM-18
STAFF LUNCH RM
EXAM-16
EXAM-15
EXAM-14
EXAM-10EXAM-7
EXAM-8 EXAM-11
OFFICE
OFFICE
EXAM-9 EXAM-12
EXAM-19
EXAM-5
EXAM-4
EXAM-3
EXAM-2
EXAM-1 CONSULT CHECK
IN/OUT
EXAM-6
WORK RM
WORK RMEXAM-20
OFFICE
EXAM-21
EXAM-22
EXAM-23
AGENT
CASHIER
CHECK IN
LAB
STORAGE
WOMENS
TOILET
PUBLIC
TOILET
DRAW
DRAW
DRAW
DRAW
DRAW
DRAW
FAMILY
TOILET
OFFICE
CARE
COORD
TOILET
RECEPTION
OFFICE
TRA…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .