This solicitation is for a firm-fixed-price construction contract to build a new 26,000 square foot administration building at the Malcom Randall VA Medical Center in Gainesville, Florida. The scope of work includes architectural, site, structural, fire protection, HVAC, plumbing, electrical, earthwork, exterior utilities, demolition of existing structures, and all other aspects of construction required by the contract drawings and specifications. The Department of Veterans Affairs, through the Veterans Health Administration Program Contracting Activity Central, will award a single contract to complete design-bid-build construction of the Administration Building POD 1A project. The solicitation number is 36C77621B0013.
View the file
Other files for this federal contract opportunity
Show all 32
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ABBREV ABBREVIATION
ACI AMERICAN CONCRETE INSTITUTE
ADD ADDITIVE
ADDL ADDITIONAL
AFF ABOVE FINISHED FLOOR
AISC AMERICAN INSTITUTE OF STEEL
CONSTRUCTION
AISI AMERICAN IRON AND STEEL INSTITUTE
ALT ALTERNATE/ALTERNATIVE
ALUM ALUMINUM
ARCH ARCHITECTURE/ARCHITECTURAL
ASTM AMERICAN SOCIETY OF TESTING MATERIALS
AWS AMERICAN WELDING SOCIETY
B/ BOTTOM OF
BCX BOTTOM CHORD EXTENSION
BLDG BUILDING
BLK BLOCK
BM BEAM
BOT BOTTOM
BP BASE PLATE/BEARING PLATE
BRG BEARING
BTWN BETWEEN
C CHANNEL
CB CONCRETE BEAM
CC CONCRETE COLUMN
CF CUBIC FEET (FOOT)
CIP CAST IN PLACE
CJ CONTRACTION JOINT
CL CENTERLINE
CLR CLEAR/CLEARANCE
CM CONCRETE MASONRY
CMU CONCRETE MASONRY UNIT
CO COMPANY
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
CONN CONNECTION
CONST CONSTRUCTION
COORD COORDINATE
CSJ CONSTRUCTION JOINT
CTR CENTER
CTRD CENTERED
CY CUBIC YARD
DEPT DEPARTMENT
DET DETAIL
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DIST DISTANCE
DL DEAD LOAD
DN DOWN
DWG DRAWING
EA EACH
EE EACH END
EF EACH FACE
EHPA EMERGENCY HURRICANE PROTECTION AREA
EJ EXPANSION JOINT
ELEC ELECTRIC/ELECTRICAL
EL, ELEV ELEVATION
ENGR ENGINEER
EOD EDGE OF DECK
EOR ENGINEER OF RECORD
EQ SP EQUAL SPACED
ES EACH SIDE
EW EACH WAY
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR
F FOUNDATION
FD FLOOR DRAIN
FDN FOUNDATION
FF FINISHED FLOOR
FIN FINISH
FIN GR FINISH GRADE
FLR FLOOR
FS FAR SIDE
FT FEET/FOOT
FTG FOOTING
GA GAGE/GAUGE
GALV GALVANIZED
GB GRADE BEAM
GC GENERAL CONTRACTOR
GEN GENERAL
GL GRID LINE
GS GALVANIZED STEEL
HD HOT DIPPED
HDG HOT DIPPED GALVANIZED
HORIZ HORIZONTAL
HSA HEADED STUD ANCHOR
HSS HOLLOW STRUCTURAL SECTION
HT HEIGHT
I MOMENT OF INERTIA
ID INSIDE DIAMETER
I.F. INSIDE FACE
IN. INCH
INT INTERIOR
JST JOIST
JT JOINT
K KIP (1000 LB)
KLF KIPS PER LINEAL FOOT
KSI KIPS PER SQUARE INCH
KWY KEYWAY
LB POUND
LGTH LENGTH
LL LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LONG. LONGITUDINAL
LSL LAMINATED STRAND LUMBER
LT WT LIGHT WEIGHT
LVL LAMINATED VENEER LUMBER
MATL MATERIAL
MAX MAXIMUM
MB MASONRY BEAM
MC MISCELLANEOUS CHANNEL/MASONRY
COLUMN
MECH MECHANICAL
MET METAL
MFR MANUFACTURE/MANUFACTURER
MID MIDDLE
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MPH MILES PER HOUR
NGVD NATIONAL GEODETIC VERTICAL DATUM
NIC NOT IN CONTRACT
NO. NUMBER
NS NEAR SIDE
NTS NOT TO SCALE
OC ON CENTERS
OD OUTSIDE DIAMETER
O.F. OUTSIDE FACE
OPNG OPENING
OPP OPPOSITE
OSB ORIENTED STRAND BOARD
P/C PRECAST CONCRETE/PILE CAP
P/T POST TENSIONED
PAR PARALLEL
PCB PRECAST CONCRETE BEAM
PCC PRECAST CONCRETE COLUMN
PCF POUNDS PER CUBIC FEET
PEMB PRE-ENGINEERED METAL BUILDING
PEN PENETRATION
P.J. PANEL JOINT CENTERLINE
PL PLATE
PLF POUNDS PER LINEAR FOOT
PLMG PLUMBING
PLY. PLYWOOD
PREFAB PREFABRICATED
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PSL PARALLEL STRAND LUMBER
PT PRESSURE TREATED
R/W REINFORCED WITH
RD ROOF DRAIN
REF REFERENCE
REINF REINFORCING
REQD REQUIRED
REV REVISION
RTN RETURN
RTU ROOF TOP UNIT
SB SOFFIT BEAM
SCHED SCHEDULE
S.F. SQUARE FEET
SF STRIP FOUNDATION
SIM SIMILAR
SPC SPACE/SPACES
SPECS SPECIFICATIONS
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STIFF STIFFENER
STL STEEL
STRUCT STRUCTURAL
SYM SYMMETRICAL
T/ TOP OF
TB TIE BEAM
T&B TOP AND BOTTOM
TCX TOP CHORD EXTENSION
TDS TURN DOWN SLAB
TE THICKENED EDGE
TEMP TEMPERATURE
TENS TENSION
THD THREAD/THREADED
THK THICK
TOL TOLERANCE
TRANS TRANSVERSE
TS TUBE STEEL
T.S. THICKENED SLAB
TWF THICKENED WALL FOUNDATION
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VERT VERTICAL
VIF VERIFY IN FIELD
VOL VOLUME
W WIDE FLANGE SECTION
W/ WITH
W/O WITHOUT
WD WOOD
WF WALL FOOTING
WP WATERPROOF
W.P. WORKING POINT
WS WELDED STUD
WT WEIGHT/STRUCTURAL TEE SECTION
WWF WELDED WIRE FABRIC
@ AT DESIGNATION
# POUNDS / REBAR SIZE NUMBER
+/- PLUS OR MINUS
L ANGLE
C.L. CENTER LINE
& AND
Sx SECTION MODULUS Ix MOMENT OF INERTIA
STRUCTURAL ABBREVIATIONS
X
X
X
CIP CONCRETE COLUMN ABOVE
METAL DECK
CONCRETE SLAB ON METAL DECK
STEPPED FOUNDATION
STRUCTURAL SYMBOLS AND LEGEND
MOMENT CONNECTION
NORTH ARROW
SPAN DIRECTION
SECTION / DETAIL MARK
ELEVATION MARK
RECESS OR STEP IN SLAB
PLAN / DETAIL MARK
PLAN NOTE
COLUMN GRID LINE
COLUMN AND FOUNDATION
TYPE MARKS
SLOPED SURFACE
PITCHED ROOF
WALL TYPES
S .F
STEP HEIGHTSTEP FOUNDATION
DETAIL NUMBER
SHEET NUMBER
DETAIL NUMBER
SHEET NUMBER
RUN
RISE
NOTE: SYMBOLS AND LEGEND SHOWN ARE
GENERIC AND DO NOT NECESSARILY INDICATE
ACTUAL OCCURRENCES IN THESE DRAWINGS.
CIP CONCRETE WALL
X
SPOT ELEVATION, TYPICALLY
TOP OF ITEM TAGGED
(T/WALL, T/FOUNDATION,
ETC)
X'-X"
P-X
PANEL TYPE
SEE SCHEDULE
12M
WALL TYPE DESIGNATION
TAG
NUMBER OF WELDED STUDS
SPACED EQUALLY ALONG BEAM
SIZE DESIGNATION
AMOUNT OF MIDSPAN
CAMBER, UP
W24x55 [56] c=2" COMPOSITE BEAM DESIGNATION
(20)(20)(20)(20)
COMPOSITE STEEL GIRDER DESIGNATIONW36x194 (90) c=1"
AMOUNT OF MID-SPAN
CAMBER, TYP.
SIZE DESIGNATION
TOTAL NUMBER OF WELDED STUDS
PORTION OF TOTAL NUMBER
OF WELDED STUDS TO BE
SPACED EQUALLY BETWEEN
INTERSECTING BEAMS
INTERSECTING BEAM, TYP.
INCREASED FLOOR LOAD
AREA IN PSF
F6.0
CC-1
NON-LOAD BEARING MASONRY WALL
X
SLOPE
STUD WALL
T/
X'-X"
X
X
MALCOM RANDAL VA HOSPITAL
ADMINISTRATION BUILDING
GARY C. KRUEGER, P.E.
FLORIDA LICENSE #40788
IF THIS DRAWING IS LESS THAN 30" X
42" IT IS A REDUCED SIZE DRAWING
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management xxxx -xxxx
VAWPBMC PLANNING AND ENGINEERING
FLGAINESVILLE -
BLDG #
573-360 o n e e ig h t h i n c h o n e f o o t 16
B
A
C
D
E
F t h r e e i n c h e s o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t o n e i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e e ig h t h s i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t
VA FORM 08−6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
P.O. Box 1296, Winter Park, FL 32790 Tel 407.467.8833 - Fax 407.926.0701
1 2 3 4 5 6 87 9
CONSTRUCTION DOCUMENTS
7370 Cabot Court, Suite 103
Melbourne, FL 32940
COA #15 TLC NO:
Phone: 321-636-0274
Fax: 321-639-8986 www.tlc-engineers.com
Copyright 2021 TLC Engineering Solutions, Inc.c
06/18/2021
/ 1 /2
:1 :0
P
M C
R e v it
L o c a ls
\5
-V A
G a in e s v ill e A d m in B u ild in g
S
T R
R m a tt .o liv e
.r v t
MTOCGT
SA-001
STRUCTURAL
ABBREVIATIONS,
SYMBOLS AND NOTES
518056
STRUCTURAL SHEET INDEX
SHEET # SHEET TITLE
SA-001 STRUCTURAL ABBREVIATIONS, SYMBOLS AND NOTES
SA-002 STRUCTURAL NOTES
SA-003 WIND LOAD DIAGRAM AND NOTES
SA-004 DESIGN LOAD DATA
SA-005 SPECIAL INSPECTION TABLES
SB-101 FOUNDATION PLAN
SF-101 FIRST FLOOR FRAMING PLAN
SF-102 SECOND FLOOR FRAMING PLAN
SF-103 ROOF/FUTURE THIRD FLOOR FRAMING PLAN
SF-104 UPPER ROOF FRAMING PLAN
SF-110 BRIDGE PLANS - BID OPTION 1
SF-201 ENLARGED PLANS
SJ-105 CANOPY PLANS
SJ-201 WALL ELEVATION DETAILS
SJ-202 WALL ELEVATIONS
SJ-203 WALL ELEVATIONS
SJ-204 WALL ELEVATIONS
SJ-205 WALL ELEVATIONS
SJ-401 STRUCTURAL SECTIONS
SJ-402 BRIDGE SECTIONS - BID OPTION 1
SJ-403 STRUCTURAL SECTIONS
SJ-404 STRUCTURAL SECTIONS
SJ-405 STRUCTURAL SECTIONS
SJ-501 STRUCTURAL DETAILS
SJ-502 STRUCTURAL DETAILS
SJ-503 STRUCTURAL DETAILS
SJ-504 STRUCTURAL DETAILS
SJ-505 STRUCTURAL DETAILS
SJ-506 STRUCTURAL DETAILS
SJ-601 COLUMN SCHEDULE
SJ-602 COLUMN SCHEDULE
17. IN THE EVENT THAT THE STRUCTURAL CONTRACTS DRAWINGS AND SPECIFICATIONS CONFLICT ON INFORMATION, THE STRUCTURAL CONTRACT DRAWINGS SHALL SUPERSEDE THE SPECIFICATIONS.
16. THE USE OF REPRODUCTIONS OF THESE CONTRACT DOCUMENTS AND USE OF CAD FILES BY ANY
CONTRACTOR, SUBCONTRACTOR, ERECTOR, FABRICATOR OR MATERIAL SUPPLIER IN LIEU OF
PREPARATION OF SHOP DRAWINGS SIGNIFY HIS ACCEPTANCE OF ALL INFORMATION SHOWN HEREON AS CORRECT, AND OBLIGATES HIMSELF TO ANY JOB EXPENSE, REAL OR IMPLIED, ARISING DUE TO ANY
ERRORS THAT MAY OCCUR HEREON.
15. FINISH FLOOR ELEVATION (FIRST FLOOR) OF 88'-2 3/4" IS USED AS A REFERENCE ELEVATION. SEE CIVIL
DRAWINGS FOR ACTUAL ELEVATION.
14. NO PROVISIONS HAVE BEEN MADE FOR VERTICAL OR HORIZONTAL EXPANSION EXCEPT AS SHOWN ON
CONTRACT DOCUMENTS.
13. IN THE PROFESSIONAL OPINION OF TLC ENGINEERING FOR ARCHITECTURE, INC. THE STRUCTURAL CONTRACT DOCUMENTS FOR THIS PROJECT HAVE BEEN PREPARED IN ACCORDANCE WITH THE DESIGN
CRITERIA AS SET FORTH IN THE 2015 INTERNATIONAL BUILDING CODE (IBC).
12. STRUCTURAL ENGINEER OF RECORD IS NOT RESPONSIBLE FOR THE DESIGN OF STEEL STAIRS, HANDRAILS, CURTAIN WALL/WINDOW WALL SYSTEMS, COLD-FORMED STEEL FRAMING, OR OTHER
SYSTEMS NOT SHOWN IN THE STRUCTURAL DOCUMENTS. SUCH SYSTEMS SHALL BE DESIGNED,
FURNISHED, AND INSTALLED AS REQUIRED BY OTHER PORTIONS OF THE CONTRACT DOCUMENTS.
11. ALL STRUCTURES REQUIRE PERIODIC MAINTENANCE TO EXCEED LIFE SPAN AND TO ENSURE
STRUCTURAL INTEGRITY FROM EXPOSURE TO THE ENVIRONMENT. A PLANNED PROGRAM OF
MAINTENANCE SHALL BE ESTABLISHED BY THE OWNER. THIS PROGRAM SHALL INCLUDE ITEMS SUCH AS, BUT NOT LIMITED TO, PAINTING OF STRUCTURAL STEEL, PROTECTIVE COATINGS FOR CONCRETE, SEALANTS, CAULKED JOINTS, EXPANSION JOINTS, CONTROL JOINTS, SPALLS AND CRACKS IN CONCRETE, AND PRESSURE WASHING OF EXPOSED STRUCTURAL ELEMENTS EXPOSED TO SALT ENVIRONMENT OR
OTHER HARSH CHEMICALS.
10. PERIODIC SITE OBSERVATION BY FIELD REPRESENTATIVES OF TLC ENGINEERING FOR ARCHITECTURE IS SOLELY FOR THE PURPOSE OF DETERMINING IF THE WORK OF THE CONTRACTOR IS PROCEEDING IN
GENERAL ACCORDANCE WITH THE STRUCTURAL CONTRACT DOCUMENTS. THIS LIMITED SITE
OBSERVATION SHALL NOT BE CONSTRUED AS EXHAUSTIVE OR CONTINUOUS TO CHECK THE QUALITY OR
QUANTITY OF THE WORK.
9. THE STRUCTURAL ENGINEER'S OBLIGATIONS TO REVIEW SHOP DRAWINGS AND OTHER SUBMITTALS AND TO RETURN THEM IN A TIMELY MANNER ARE CONDITIONED UPON THE PRIOR REVIEW AND APPROVAL OF THE SHOP DRAWINGS OR SUBMITTALS BY THE CONTRACTOR AS REQUIRED IN THE CONSTRUCTION CONTRACT AND THE CONTRACTOR'S SUBMITTAL OF THE SHOP DRAWINGS AND OTHER SUBMITTALS IN ACCORDANCE WITH A WRITTEN SCHEDULE DISTRIBUTED IN ADVANCE TO THE ENGINEER IDENTIFYING THE
DATES FOR THE SUBMITTAL OF THE VARIOUS SHOP DRAWINGS AND SUBMITTALS.
8. THE CONTRACT STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE, AND DO NOT INDICATE THE METHOD OR MEANS OF CONSTRUCTION. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, PROCEDURES, TECHNIQUES, SEQUENCE AND SAFETY. THE ENGINEER DOES NOT HAVE CONTROL OR CHARGE OF, AND SHALL NOT BE RESPONSIBLE FOR, CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, OR PROCEDURES, FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK, FOR THE ACTS OR OMISSION OF THE CONTRACTOR, SUBCONTRACTOR OR ANY OTHER PERSONS PERFORMING ANY OF THE WORK, OR FOR THE FAILURE OF ANY OF THEM TO CARRY OUT THE WORK IN
ACCORDANCE WITH THE CONTRACT DOCUMENTS.
7. THE GENERAL CONTRACTOR SHALL COMPARE THE ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, CIVIL AND STRUCTURAL DRAWINGS AND REPORT ANY DISCREPANCIES BETWEEN EACH SET OF DRAWINGS AND WITHIN EACH SET OF DRAWINGS TO THE ARCHITECT AND ENGINEER OF RECORD PRIOR
TO THE FABRICATION AND INSTALLATION OF ANY STRUCTURAL MEMBERS.
6. DETAILS LABELED "TYPICAL DETAILS" ON THE DRAWINGS SHALL APPLY TO ALL SITUATIONS OCCURRING
ON THE PROJECT THAT ARE THE SAME OR SIMILAR TO THOSE SPECIFICALLY DETAILED. THE
APPLICABILITY OF THE DETAIL TO ITS LOCATION ON THE DRAWINGS CAN BE DETERMINED BY THE TITLE OF DETAIL. SUCH DETAILS SHALL APPLY WHETHER OR NOT THEY ARE REFERENCED AT EACH LOCATION.
QUESTIONS REGARDING APPLICABILITY OF TYPICAL DETAILS SHALL BE DETERMINED BY THE ENGINEER
OF RECORD.
5. THE STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THE BUILDING IS COMPLETE.
IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES AND SEQUENCE TO ENSURE SAFETY OF THE BUILDING AND ITS COMPONENTS DURING ERECTION. THIS INCLUDES THE
ADDITION OF NECESSARY SHORING, SHEETING, TEMPORARY BRACING, GUYS OR TIEDOWNS.
4. DO NOT SCALE DRAWINGS.
3. NO STRUCTURAL MEMBER OR COMPONENT SHALL BE CUT, NOTCHED, OR OTHERWISE ALTERED UNLESS APPROVED IN WRITING BY THE ENGINEER OF RECORD. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY AND ALL COSTS INCURRED BY THE ENGINEER OF RECORD FOR REVIEW OF ANY SUCH DEVIATIONS.
2. DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER OF RECORD BEFORE PROCEEDING WITH THE AFFECTED PART OF
THE WORK.
1. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH PROJECT SPECIFICATIONS AND ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, AND SITE DRAWINGS. CONSULT THESE DRAWINGS FOR OPENINGS, DEPRESSIONS, EQUIPMENT WEIGHTS AND LOCATIONS, EMBEDDED ITEMS AND
OTHER DETAILS NOT SHOWN ON STRUCTURAL DRAWINGS.
1000 GENERAL NOTES
SEISMIC IMPORTANCE FACTOR 1.0
SEISMIC DESIGN CATEGORY A
SEISMIC USE GROUP II
SITE CLASSIFICATION D
SPECTRAL RESPONSE ACCELERATION, 1.0 SECOND DURATION (S1) 0.049
SPECTRAL RESPONSE ACCELERATION, SHORT DURATION (Ss) 0.088
2.4 SEISMIC LOADS: PER ASCE 7-10.
EXPOSURE B
RISK CATEGORY II
NOMINAL DESIGN WIND SPEED, Vasd 97 MPH (3 SEC. GUST)
ULTIMATE DESIGN WIND SPEED, Vult 125 MPH (3 SEC. GUST)
SEE SHEET SS-003 FOR COMPONENTS AND CLADDING PRESSURES
2.3 WIND LOADS: PER FLORIDA BUILDING CODE, SECTION 1609.
200 LBS
(CONCENTRATED)
GUARDRAILS/HANDRAILS 50 PLF (UNIFORM)
STAIRS AND EXITS 100 PSF
FLOOR (MECH. & ELEC. ROOM) 150 PSF
FLOOR (FUTURE) 100 PSF
FLOOR (LEVEL 2) 80 PSF
ROOF 20 PSF
2.2 LIVE LOADS
STEEL STUDS W/ GYP. BOARD PARTITIONS 20 PSF
CEILINGS 5 PSF
M/E/P LOADS 5 PSF
ROOF STRUCTURE 15 PSF
2.1 DEAD LOADS
SEE SHEET SA-004 FOR ADDITIONAL FUTURE FLOOR LOADING INFORMATION.
2. THE FOLLOWING SUPERIMPOSED LOADINGS HAVE BEEN UTILIZED:
BLAST AND PHYSICAL SECURITY 50% DESIGN NARRATIVEPREPARED BY PROTECTION ENGINEERING
CONSULTANTS, NOVEMBER 16, 2018
DEPARTMENT OF VETERANS AFFAIRS NEW ADMINISTRATION BUILDING - GAINESVILLE, FL
J. BLAST AND PHYSICAL SECURITY CRITERIA:
I. STRUCTURAL WELDING CODE - STEEL, AMERICAN WELDING SOCIETY (AWS), ANSI/AWS D1.1-2011.
H. ALLOWABLE STRESS DESIGN SPECIFICATION FOR COLD-FORMED STEEL STRUCTURAL MEMBERS, AMERICAN IRON AND STEEL INSTITUTE (AISI), 2012.
G. STEEL CONSTRUCTION MANUAL, AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC), 14TH ADDITION.
F. BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE, AMERICAN CONCRETE INSTITUTE ACI 318-14.
E. MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, AMERICAN SOCIETY OF CIVIL
ENGINEERS, ASCE 7-10.
D. SEISMIC DESIGN REQUIREMENTS, DEPARTMENT OF VETERANS AFFAIRS, H-18-8.
C. STRUCTURAL DESIGN MANUAL FOR REGIONAL OFFICE PROJECTS, DEPARTMENT OF VETERANS AFFAIRS.
B. DEPARTMENT OF VETERANS AFFAIRS PHYSICAL SECURITY DESIGN MANUAL, JANUARY 2015.
A. INTERNATIONAL BUILDING CODE, 2015 EDITION.
1. DESIGN/CONSTRUCTION CRITERIA:
1060 DESIGN LOADS
3. STORY DRIFT: LATERAL FRAME DEFLECTION OF H/400 IN THE PLANE OF THE WALL OF ONE FLOOR RELATIVE TO AN ADJACENT FLOOR SHALL BE TAKEN INTO ACCOUNT IN THE DESIGN, FABRICATION AND
INSTALLATION OF THE BUILDING CLADDING.
B. TYPICAL ROOF MEMBERS - SPAN/360 BUT NOT LESS THAN 3/8"
A. TYPICAL FLOOR MEMBERS - SPAN/360 BUT NOT LESS THAN 3/8"
2. THE FOLLOWING PROVISION FOR SUPERIMPOSED LOAD DEFLECTIONS SHALL BE MADE IN THE DESIGN, FABRICATION, AND INSTALLATION OF ALL PARTITIONS, GLASS WALLS, AND OTHER ELEMENTS SUPPORTED
BY AND ATTACHED TO THE STRUCTURE.
A. TYPICAL SPANDREL BEAM - 3/8"
SUPERIMPOSED LOAD DEFLECTION IS DEFINED AS ALL DEFLECTION ANTICIPATED TO OCCUR AFTER THE CLADDING HAS BEEN ERECTED. THE RELATIVE DEFLECTION ABOVE DOES NOT INCLUDE THE FLOOR DEFLECTION CAUSED BY THE WEIGHT OF THE CLADDING ITSELF OR THE DEAD LOAD DEFLECTION OF THE FLOOR FRAMING ITSELF, NOR DOES IT INCLUDE ANY ALLOWANCE FOR FABRICATION OR ERECTION
TOLERANCES.
1. SPANDREL BEAM DEFLECTIONS. THE FOLLOWING PROVISION SHOULD BE MADE FOR SUPERIMPOSED LOAD DEFLECTION OF ONE FLOOR RELATIVE TO AN ADJACENT FLOOR IN THE DESIGN, FABRICATION, AND
ERECTION OF THE BUILDING CLADDING.
THE BUILDING MOVEMENT SPECIFIED HEREIN IS ANTICIPATED TO OCCUR AND SHOULD BE CONSIDERED BY
THE CONTRACTOR IN THE PERFORMANCE OF THE WORK.
1010 BUILDING MOVEMENTS
NO. DESCRIPTION DATE
1 REISSUED FOR ADDENDUM 1 10/18/2021
MALCOM RANDAL VA HOSPITAL
ADMINISTRATION BUILDING
GARY C. KRUEGER, P.E.
FLORIDA LICENSE #40788
IF THIS DRAWING IS LESS THAN 30" X
42" IT IS A REDUCED SIZE DRAWING
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management xxxx -xxxx
VAWPBMC PLANNING AND ENGINEERING
FLGAINESVILLE -
BLDG #
573-360 o n e e ig h t h i n c h o n e f o o t 16
B
A
C
D
E
F t h r e e i n c h e s o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t o n e i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e e ig h t h s i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t
VA FORM 08−6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
P.O. Box 1296, Winter Park, FL 32790 Tel 407.467.8833 - Fax 407.926.0701
1 2 3 4 5 6 87 9
CONSTRUCTION DOCUMENTS
7370 Cabot Court, Suite 103
Melbourne, FL 32940
COA #15 TLC NO:
Phone: 321-636-0274
Fax: 321-639-8986 www.tlc-engineers.com
Copyright 2021 TLC Engineering Solutions, Inc.c
06/18/2021
/ 1 /2
:1 :0
P
M C
R e v it
L o c a ls
\5
-V A
G a in e s v ill e A d m in B u ild in g
S
T R
R m a tt .o liv e
.r v t
MTOCGT
SA-002
STRUCTURAL NOTES
518056
5. CHANGES AND ADDITIONS MADE ON RE-SUBMITTALS SHALL BE CLEARLY FLAGGED AND NOTED. THE PURPOSE OF THE RE-SUBMITTALS SHALL BE CLEARLY NOTED ON THE LETTER OF TRANSMITTAL.
ARCHITECT/ENGINEER OF RECORD REVIEW WILL BE LIMITED TO THOSE ITEMS CAUSING THE
RE-SUBMITTAL. CONTRACTOR IS RESPONSIBLE FOR COSTS CAUSED BY MULTIPLE RE-SUBMITTALS (MORE
THAN ONE) AT ARCHITECT/ENGINEERS' CURRENT HOURLY RATES.
4. THE CONTRACT DOCUMENTS WILL GOVERN OVER THE SHOP DRAWINGS UNLESS OTHERWISE SPECIFIED
IN WRITING BY THE ENGINEER OF RECORD.
3. SHOP DRAWING SUBMITTALS SHALL INCLUDE, AT A MINIMUM, ONE GOOD QUALITY REPRODUCIBLE AND THREE SETS OF BLUEPRINTS. ONE SET OF PRINTS WILL BE RETAINED BY THE ENGINEER OF RECORD, ONE
BY THE ARCHITECT, ONE BY THE LOCAL BUILDING DEPARTMENT (WHERE REQUIRED) AND THE
CONTRACTOR SHALL MAKE PRINTS FROM THE REPRODUCIBLE AS REQUIRED FOR DISTRIBUTION.
2. SHOP DRAWINGS SHALL BE REVIEWED BY THE CONTRACTOR AND MARKED "APPROVED" PRIOR TO SUBMITTAL TO THE ARCHITECT/ENGINEER. NON-CONFORMING DRAWING SUBMITTALS WILL BE RETURNED
WITHOUT REVIEW.
1. SHOP DRAWINGS SHALL ADEQUATELY DEPICT THE STRUCTURAL ELEMENTS AND CONNECTIONS SHOWN ON THE CONTRACT DOCUMENTS. SHOP DRAWINGS WILL BE REVIEWED FOR GENERAL COMPLIANCE WITH THE DESIGN INTENT OF THE CONTRACT DOCUMENTS ONLY. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY COMPLIANCE WITH THE CONTRACT DOCUMENTS AS TO QUANTITY, LENGTH, ELEVATIONS, DIMENSIONS, ETC. REVIEW OF SUBMITTALS AND SHOP DRAWINGS DOES NOT RELIEVE THE
CONTRACTOR OF FULL RESPONSIBILITY FOR ERRORS AND OMISSIONS ASSOCIATED WITH THE
PREPARATION OF THE SHOP DRAWINGS.
1330 SHOP DRAWING REVIEW
3. MANUFACTURER'S LITERATURE. SUBMIT TWO COPIES OF MANUFACTURER'S LITERATURE FOR ALL
MATERIALS AND PRODUCTS USED IN CONSTRUCTION ON THE PROJECT.
N. POST-INSTALLED MECHANICAL ANCHORS (#)
M. POST-INSTALLED ADHESIVE ANCHORS (#)
L. FORMWORK AND TEMPORARY SHORING (D)
K. TEMPORARY WALL BRACING (D)
J. CURTAIN WALL SYSTEMS (D)
I. ELEVATORS (#)
H. CONCRETE MIX DESIGNS
G. ARCHITECTURAL SUNSCREEN (D)
F. ALUMINUM STRUCTURES AND CANOPIES (D)
E. STRUCTURAL COLD-FORMED STEEL (CFS) FRAMING (D)
D. COMPOSITE METAL DECK
C. STEEL STAIRS (D)
B. REINFORCING STEEL
A. STRUCTURAL STEEL (D)
• ITEMS MARKED (#) SHALL BE SUBMITTED FOR ENGINEERS RECORD ONLY.
• ITEMS MARKED (D) SHALL HAVE SHOP DRAWINGS SEALED BY A PROFESSIONAL ENGINEER
REGISTERED IN THE STATE OF FLORIDA.
2. THE GENERAL CONTRACTOR SHALL SUBMIT FOR ENGINEER REVIEW SHOP DRAWINGS FOR THE
FOLLOWING ITEMS:
1. ALL SHOP DRAWINGS MUST BE REVIEWED AND STAMPED APPROVED BY THE GENERAL CONTRACTOR
PRIOR TO SUBMITTAL.
1333 SUBMITTALS
3. RFI RESPONSES ARE NOT INTENDED TO AUTHORIZE ANY INCREASE IN CONSTRUCTION COST, SCHEDULE OR TIME EXTENSIONS, OR CONSTRUCTION IN CONFLICT WITH ANY APPLICABLE CODES OR SPECIFIED DESIGN STANDARDS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE DESIGN TEAM
IMMEDIATELY OF ANY PERCEIVED SCOPE, SCHEDULE, OR COST IMPACTS OR ADJUSTMENTS. IF
CONTRACTOR REQUESTS ANY ADDITIONAL COST, INCREASE IN SCHEDULE OR ADJUSTMENT IN SCOPE, THE CONTRACTOR SHALL NOT PROCEED WITH ADDITIONAL WORK UNTIL APPROVED IN WRITING BY THE
CONSTRUCTION ADMINISTRATOR.
2. RFI SHALL BE SUBMITTED AS SPECIFIED WITHIN THE CONTRACT DOCUMENTS AND SHALL BE FORWARDED TO THE ENGINEER VIA THE ARCHITECT OR DIRECTLY TO THE ENGINEER BY THE CONTRACTOR WHEN
APPROVED BY THE ARCHITECT.
1. RFI SHALL ORIGINATE WITH CONTRACTOR AND SHALL BE SUBMITTED IN THE FORM SPECIFIED WITHIN CONTRACT DOCUMENTS. RFI SHALL BE SUBMITTED IN A PROMPT MANNER AS TO AVOID DELAYS IN
CONTRACTORS WORK.
1334 REQUEST FOR INTERPRETATION (RFI)
3. SLABS ON GRADE SHALL BE PLACED OVER A 15 MIL, CLASS "A" VAPOR RETARDER. VAPOR RETARDER SHALL BE LAPPED A MINIMUM OF 6", OR AS RECOMMENDED BY THE MANUFACTURER (WHICHEVER IS GREATER) AND TAPED AT ALL JOINTS. ALL PUNCTURES IN THE VAPOR RETARDER SHALL BE REPAIRED PER MANUFACTURER'S WRITTEN INSTRUCTIONS. ALL PENETRATIONS THROUGH THE VAPOR RETARDER
(COLUMNS, PLUMBING, CONDUITS, ETC) SHALL BE SEALED PER MANUFACTURER'S WRITTEN
INSTRUCTIONS. VAPOR RETARDER SHALL BE CONTINUOUS UNDER WALL FOUNDATIONS OR SEALED TO
EXTERIOR WALLS PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
E. DEWATERING MAY BE REQUIRED TO ACHIEVE THE REQUIRED COMPACTION VALUES, AND IF USED, SHOULD DRAW DOWN THE WATER LEVEL TO AT LEAST 2 FEET BELOW THE BOTTOM OF THE
EXCAVATION.
D. EXCAVATIONS FOR FOUNDATIONS SHALL BE COMPACTED TO 95% FOR A DEPTH OF AT LEAST 2 FEET
BELOW THE BOTTOM OF THE FOUNDATION.
C. ALL FILL SHALL BE CLEAN SAND AND FREE OF ORGANIC MATERIALS. COMPACT FILL IN 12 INCH (UNCOMPACTED THICKNESS) LIFTS TO A MINIMUM OF 95% OF THE MODIFIED PROCTOR MAXIMUM DRY
DENSITY VALUE.
B. PROOF ROLLING THE BUILDING SITE TO LOCATE ANY UNFORESEEN SOFT AREAS. ANY SOFT AREAS SHALL BE EXCAVATED AND REPLACED WITH CLEAN FILL. A DENSITY OF AT LEAST 95% FOR A DEPTH OF
2 FEET IS REQUIRED UNDER THE BUILDING FOOTPRINT.
A. STRIPPING AND GRUBBING OF THE BUILDING FOOTPRINT PLUS A MARGIN OF 5 FEET AROUND THE
BUILDING, REMOVING ALL ORGANIC MATERIALS.
2. FOLLOW THE RECOMMENDATIONS LISTED IN THE GEOTECHNICAL REPORT FOR SITE PREPARATION WORK.
AT A MINIMUM, SITE PREPARATION WORK SHALL INCLUDE:
DATED: JULY 3, 2018
TITLED: REPORT OF GEOTECHNICAL CONSULTING
SERVICES, MALCOM RANDEL VA HOSPITAL
- ADMINISTRATION BUILDING.
PREPARED BY: UNIVERSAL ENGINEERING SERVICES
REPORT No. 1582115
1. SEE THE FOLLOWING GEOTECHNICAL REPORT FOR COMPLETE GEOTECHNICAL RECOMMENDATIONS AND INSTALLATION PROCEDURES. SITE PREPARATION AND FOUNDATION INSTALLATION SHALL COMPLY WITH:
2310 FOUNDATIONS - W/ SOIL REPORTS
14. WHEN ADHESIVES OR WATER VAPOR IMPERMEABLE FLOOR COVERINGS ARE BEING USED ON CONCRETE
SURFACES, THE CONTRACTOR SHALL VERIFY THROUGH APPROPRIATE TESTING THAT THE WATER
CONTENT OF THE CONCRETE, AND VAPOR TRANSMISSION RATE THROUGH THE CONCRETE, IS WITHIN THE
ALLOWABLE RANGE BEFORE INSTALLATION. THE MANUFACTURER OF THE ADHESIVE OR FLOOR
COVERING SHALL REVIEW AND APPROVE THE RESULTS OF THE TESTING PRIOR TO INSTALLATION OF
PRODUCTS.
13. CONCRETE SLABS ON COMPOSITE METAL DECK SHALL BE REINFORCED WITH 6x6 W2.9 x W2.9 WWF AT
MID-DEPTH OF SLAB.
12. CONCRETE SLABS ON GRADE SHALL BE REINFORCED WITH 6x6 W2.9 x W2.9 WWF AT MID-DEPTH OF SLAB.
11. ALL COLUMNS AND BEAMS INTEGRATED IN CMU WALLS ARE 8" AND 12" NOMINAL AND 7-5/8" AND 11-5/8"
ACTUAL DIMENSIONS.
10. CONCRETE DESIGN MIX SUBMITTALS SHALL INCLUDE TESTED, STATISTICAL BACK-UP DATA AS PER
CHAPTER 5 OF ACI 318.
9. CONDUITS, PIPES AND SLEEVES SHALL BE PLACED AND SPACED IN ACCORDANCE WITH ACI 318, 6.3.
8. CONCRETE MIX DESIGNS SHALL INCLUDE A WRITTEN DESCRIPTION INDICATING WHERE EACH PARTICULAR
MIX IS TO BE PLACED WITHIN THE STRUCTURE.
7. CALCIUM CHLORIDES SHALL NOT BE UTILIZED; OTHER ADMIXTURES MAY BE USED ONLY WITH THE
APPROVAL OF THE ENGINEER.
6. SLABS SHALL BE CURED USING A DISSIPATING CURING COMPOUND MEETING ASTM STANDARD C309 TYPE 1-CLASS D AND SHALL HAVE A FUGITIVE DYE. THE COMPOUND SHALL BE PLACED AS SOON AS THE FINISHING IS COMPLETED OR AS SOON AS THE WATER HAS LEFT THE UNFINISHED CONCRETE. SCUFFED
OR BROKEN AREAS IN THE CURING MEMBRANE SHALL BE RECOATED DAILY.
5. THE MAXIMUM TIME ALLOWED FROM THE TIME THE MIXING WATER IS ADDED UNTIL IT IS DEPOSITED IN ITS FINAL POSITION SHALL NOT EXCEED ONE AND ONE HALF (1-1/2) HOURS. IF FOR ANY REASON THERE IS A LONGER DELAY THAN THAT STATED ABOVE, THE CONCRETE SHALL BE DISCARDED. IT SHALL BE THE RESPONSIBILITY OF THE TESTING LAB TO NOTIFY THE OWNER'S REPRESENTATIVE AND THE CONTRACTOR
OF ANY NONCOMPLIANCE WITH THE ABOVE.
4. CONCRETE SHALL COMPLY WITH THE REQUIREMENTS OF ASTM STANDARD C94 FOR MEASURING, MIXING, TRANSPORTING, ETC. CONCRETE TICKETS SHALL BE TIME STAMPED WHEN CONCRETE IS BATCHED.
3. SUBMIT PROPOSED MIX DESIGN WITH RECENT FIELD CYLINDER OR LAB TESTS FOR REVIEW PRIOR TO USE. MIX SHALL BE UNIQUELY IDENTIFIED BY MIX NUMBER OR OTHER POSITIVE IDENTIFICATION. MIX
SHALL MEET THE REQUIREMENTS OF ASTM C33 FOR COARSE AGGREGATE.
2. CONCRETE SHALL BE PLACED AND CURED ACCORDING TO ACI STANDARDS AND SPECIFICATIONS.
TOPPING 3000 PSI 4-6" 3/8 0.45
WALLS 4000 PSI 4-6" 3/8" 0.48
CONCRETE ON METAL DECK 4000 PSI 4-6" 3/4" 0.50
SLABS-ON-GRADE 4000 PSI 4-6" 3/4" 0.50
AUGER-CAST PILES 4000 PSI N/A 3/8" 0.40
GRADE BEAMS 4000 PSI 4-6" 1" 0.40
PILE CAPS 4000 PSI 4-6" 1" 0.40
FOUNDATIONS 4000 PSI 4-6" 1" 0.50
CONCRETE STRUCTURE
TYPE
COMPRESSIVE
STRENGTH
SLUMP
MAXIMUM
AGGREGATE
MAXIMUM W/C
RATIO
1. SHALL BE PER AN APPROVED MIX DESIGN PROPORTIONED TO ACHIEVE A STRENGTH AT 28 DAYS AS
LISTED BELOW WITH A PLASTIC AND WORKABLE MIX:
3302 CONCRETE
10. AT CANTILEVER SLABS AND BEAMS, REINFORCING BARS IN DIRECTION OF CANTILEVER SHALL BE DETAILED TO FULLY DEVELOP THE BAR STRENGTH INTO THE SUPPORTING STRUCTURE, EITHER BY PROVIDING FULL CLASS B LAP SPLICE OR STANDARD ACI HOOKS EMBEDDED DEEP ENOUGH BEYOND
SUPPORT TO DEVELOP STRENGTH OF BAR.
9. WHERE HOOKS ARE SHOWN ON THE PLANS OR DETAILS, HOOKS SHALL BE DETAILED TO EXTEND DEEP
ENOUGH INTO SUPPORTING STRUCTURE TO DEVELOP THE FULL STRENGTH OF THE HOOKED BAR.
PROVIDE ADDITIONAL TIES OR STIRRUPS IN SUPPORTING STRUCTURE AS REQUIRED TO SATISFY ACI 318
HOOK DEVELOPMENT, CONFINEMENT, AND ANCHORAGE CRITERIA.
8. AT CHANGES IN DIRECTION OF CONCRETE WALLS AND TIE BEAMS, PROVIDE CORNER BARS OF SAME SIZE
AND SPACING AS HORIZONTAL STEEL.
WHERE "T" IS DEPTH OF CONCRETE UNDER BARS AND "Db" IS BAR DIAMETER.
UTILIZE CLASS "B" SPLICE FOR ALL SPLICES, U.N.O. ON PLANS OR DETAILS.
#7 OR MORE 81 Db 79 Db 72 Db
T>12" #6 OR LESS 74 Db 65 Db 57 Db
#7 OR MORE 71 Db 61 Db 55 Db
T<12" #6 OR LESS 57 Db 49 Db 44 Db
BAR SIZE 3000 PSI 4000 PSI 5000 PSI
7. LENGTH OF LAP SPLICES AND BAR EMBEDMENT SHALL BE AS SHOWN IN TABLE, UNLESS OTHERWISE...
6. PROVIDE DOWELS INTO FOOTINGS, PILE CAPS, SUPPORT BEAMS, ETC. TO MATCH VERTICAL BARS WITH
CLASS B TENSION LAP SPLICES, U.N.O.
5. WHERE REINFORCING IS SHOWN CONTINUOUS, SPLICE BOTTOM BARS OVER SUPPORTS AND TOP BARS AT CENTER OF SPAN. ALL OTHER LAP SPLICES SHALL BE IN ACCORDANCE WITH SPLICE TABLES AND DETAILS
SHOWN ON DRAWINGS.
4. PROVIDE STANDARD HOOKS AT DISCONTINUOUS ENDS OF ALL TOP BARS.
3. SECURE APPROVAL OF SHOP DRAWINGS PRIOR TO COMMENCING FABRICATION.
2. BEAMS AND COLUMNS ALL BARS 1.5"
1. SLABS, WALLS, AND JOISTS #11 OR SMALLER 3/4"
C. CONCRETE NOT EXPOSED TO WEATHER OR IN
CONTACT WITH GROUND
#5 OR SMALLER 1.5"
B. CONCRETE EXPOSED TO EARTH OR WEATHER #6 OR GREATER 2"
A. CONCRETE CAST AGAINST AND PERMANENTLY
EXPOSED TO EARTH
ALL BARS 3"
LOCATION AND CONDITION MINIMUM COVER
2. PROVIDE CONCRETE COVER OVER PRIMARY REINFORCEMENT, TIES, AND STIRRUPS, AS FOLLOWS, UNLESS OTHERWISE NOTED:
1. SHALL BE ASTM A615 GRADE 60 DEFORMED BARS, FREE FROM OIL, SCALE AND RUST AND PLACED IN ACCORDANCE WITH THE TYPICAL BENDING DIAGRAM AND PLACING DETAILS OF ACI STANDARDS AND
SPECIFICATIONS.
3310 REINFORCING STEEL
4. INSTALL WWF ON BRICKS OR BOLSTERS AT MID DEPTH OF SLAB U.N.O.; SPACING OF SUPPORTS SHALL BE ADEQUATE TO PREVENT SHIFTING OF WWF DURING CONSTRUCTION, BUT SHALL NOT EXCEED 24" O.C.
3. USE OF FLAT MANUFACTURED SHEETS IS REQUIRED (NO ROLLS).
2. MINIMUM LAP SHALL BE ONE SPACE PLUS TWO INCHES.
1. SHALL CONFORM TO ASTM A-185, FREE FROM OIL, SCALE AND RUST AND PLACED IN ACCORDANCE WITH
THE TYPICAL PLACING DETAILS OF ACI STANDARDS AND SPECIFICATIONS.
3314 WELDED WIRE FABRIC
2. ALTERNATE OR ADDED CONSTRUCTION JOINT LOCATIONS ARE ACCEPTABLE ONLY AS A CHANGE ORDER, WHICH WILL INCLUDE ENGINEERING CHARGES BY THE ENGINEER OF RECORD FOR REDESIGN OF THE
STRUCTURE, SHORING, ETC.
1. ANY DEVIATION OR ADDITION OF CONSTRUCTION JOINTS FROM THAT SHOWN ON THE DRAWINGS MUST BE
REVIEWED AND APPROVED IN WRITING BY THE ENGINEER OF RECORD.
3322 CONSTRUCTION JOINTS
3. PLACE TWO #3 STIRRUPS @ 3" O.C. EACH SIDE OF SLEEVE PENETRATIONS IN BEAMS.
2. PRIOR TO CONSTRUCTION ALL SLEEVE LOCATIONS AND SIZES NOT SHOWN ON THE DRAWINGS SHALL BE
APPROVED BY THE ENGINEER.
1. MINIMUM SLEEVE SPACING SHALL BE THREE DIAMETERS CENTER TO CENTER OF THE LARGER SLEEVE
OR 6" CLEAR BETWEEN SLEEVES, WHICHEVER IS GREATER.
3324 PLUMBING SLEEVES
15. ADHESIVE ANCHORS INSTALLED IN HORIZONTAL OR UPWARDLY INCLINED ORIENTATIONS TO RESIST SUSTAINED TENSION LOADS SHALL BE CONTINUOUSLY INSPECTED DURING INSTALLATION BY AN INSPECTOR SPECIALLY APPROVED FOR THAT PURPOSE BY THE BUILDING OFFICIAL (ACI 318-11 D.9.2.4)
14. PROVIDE SPECIAL INSPECTION FOR ALL ADHESIVE ANCHORS IN ACCORDANCE WITH THE REQUIREMENTS OF THE APPLICABLE BUILDING CODE AND THE CURRENT ICC-ES REPORT (IBC-2012 TABLE 1705.3 NOTE B).
13. ADHESIVE ANCHORS IN CONCRETE AND/OR MASONRY CONSTRUCTION SHALL NOT BE INSTALLED UNTIL
CONCRETE AND/OR MASONRY HAS CURED FOR AT LEAST 21-DAYS.
12. EXISTING REINFORCING IN CONCRETE AND/OR MASONRY CONSTRUCTION SHALL NOT BE CUT UNLESS
APPROVED BY THE EOR.
11. ADHESIVE ANCHORS IN MASONRY SHALL HAVE BEEN TESTED AND QUALIFIED IN ACCORDANCE WITH
ICC-ES AC70.
10. ADHESIVE ANCHORS IN CONCRETE SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN ACCORDANCE WITH ACI 355.2 AND ICC-ES AC193 FOR CRACKED, UNCRACKED, AND SEISMIC CONCRETE RECOGNITION.
9. IF DETAIL SHOWS EPOXY ANCHORS IN SLOTTED HOLES, IT IS IMPERATIVE THAT ANY EXCESS EPOXY IS CLEANED UP FROM AROUND THE ANCHOR ROD, SO THAT IT DOES NOT INTERFERE WITH ADJUSTABILITY
OF ANCHOR ROD IN SLOTTED HOLE.
8. NO LOAD SHALL BE APPLIED TO THE EPOXY ANCHORS UNTIL THE EPOXY HAS FULLY CURED AND HAS ACHIEVED IT'S SPECIFIED STRENGTH. CURE TIME SHALL BE PER MANUFACTURERS PUBLISHED VALUES
FOR SPECIFIC PRODUCT BEING USED.
7. THE CONTRACTOR IS RESPONSIBLE TO ENSURE THAT ALL HOLE CLEAN-OUT REQUIREMENTS ARE FULLY COMPLETED BY THE INSTALLERS PRIOR TO INJECTING EPOXY INTO THE HOLES IN ACCORDANCE WITH THE
MANUFACTURERS MPII.
6. THE MANUFACTURER'S REPRESENTATIVE SHALL TRAIN INSTALLERS FOR ALL PRODUCTS TO BE USED PRIOR TO COMMENCEMENT OF WORK. ONLY TRAINED INSTALLERS SHALL PERFORM POST INSTALLED ANCHOR INSTALLATION. A RECORD OF TRAINING SHALL BE MADE AVAILABLE TO THE EOR AS REQUESTED.
5. ADHESIVE ANCHORS INSTALLED IN HORIZONTAL TO VERTICALLY OVERHEAD ORIENTATION TO SUPPORT SUSTAINED TENSION LOADS SHALL BE DONE BY A CERTIFIED ADHESIVE ANCHOR INSTALLER (AAI) AS CERTIFIED THROUGH ACI/CRSI (ACI 318-11 D.9.2.2). PROOF OF CURRENT CERTIFICATION SHALL BE
SUBMITTED TO THE ENGINEER FOR APPROVAL PRIOR TO COMMENCEMENT OF INSTALLATION.
4. INSTALL ANCHORS IN STRICT ACCORDANCE WITH MANUFACTURER'S PRINTED INSTALLATION
INSTRUCTIONS (MPII) IN CONJUNCTION WITH EDGE DISTANCE, SPACING, AND EMBEDMENT SPECIFIED ON
DRAWINGS.
3. SUBSTITUTION OF EPOXIES IN ONE CONDITION SHALL NOT BE CONSTRUED AS APPROVAL TO MAKE SIMILAR SUBSTITUTION OF EPOXIES IN OTHER DIFFERING CONDITIONS. EACH SUBSTITUTION MUST
RECEIVE PRIOR WRITTEN APPROVAL BY THE ENGINEER OF RECORD.
2. EPOXY TYPES AND BRANDS VARY IN THEIR BOND STRENGTH AND SUITABILITY OF USE, DEPENDING ON TYPE OF LOADING, ANCHOR SPACING, ETC. WHEN A PARTICULAR TYPE OF EPOXY IS SPECIFIED IN THESE DRAWINGS, A UNIQUE CALCULATION HAS BEEN MADE BASED ON THE PROPERTIES OF THAT SPECIFIC TYPE OF EPOXY FOR THE SPECIFIC CONDITION SHOWN IN THE DETAIL. SUBSTITUTION OF EPOXY TYPE IS
NOT ALLOWED WHERE DETAIL SPECIFIES ONLY ONE TYPE OF EPOXY, WITHOUT PRIOR WRITTEN
APPROVAL BY THE ENGINEER OF RECORD. NOT ALL EPOXY BRANDS OR TYPES WILL BE ALLOWED AS SUBSTITUTES. ICC-ES REPORTS FOR PROPOSED ANCHOR SUBSTITUTIONS MUST BE SUBMITTED TO EOR
FOR REVIEW. EOR MAY REQUIRE ENGINEERED CALCULATIONS FOR REVIEW AND APPROVAL.
1. SHALL BE A TWO PART EPOXY POLYMER INJECTION SYSTEM, SUCH AS HILTI HIT HY200, HILTI RE500 SD, POWERS PURE 100+, OR SIMPSON SET ADHESIVE SYSTEM, OR ENGINEER APPROVED SUBSTITUTION.
3601 CHEMICAL (ADHESIVE) ANCHORS
13. PROVIDE SPECIAL INSPECTION FOR ALL MECHANICAL POST INSTALLED ANCHORS IN ACCORDANCE WITH THE REQUIREMENTS OF THE APPLICABLE BUILDING CODE AND THE CURRENT ICC-ES REPORT (IBC2012
TABLE 1705.3 NOTE B).
12. ANCHORS SHALL NOT BE INSTALLED IN CONCRETE AND/OR MASONRY CONSTRUCTION UNTIL THE
CONCRETE AND/OR MASONRY HAS CURED FOR AT LEAST 21-DAYS.
11. EXISTING REINFORCING BARS IN CONCRETE AND/OR MASONRY CONSTRUCTION SHALL NOT BE CUT
UNLESS APPROVED BY THE EOR.
10. POWER ACTUATED FASTENERS SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN ACCORDANCE
WITH ICC0ES AC70.
9. MECHANICAL ANCHORS IN MASONRY SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN
ACCORDANCE WITH ICC-ES AC01 OR AC106.
8. MECHANICAL ANCHORS IN CONCRETE SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN ACCORDANCE WITH ACI 355.2 AND ICC-ES AC 193 FOR CRACKED, UNCRACKED AND SEISMIC CONCRETE
RECOGNITION.
7. TAPCON SCREWS, OR POWERS TAPPER +, MAY BE REPLACED W/ 0.157" SHANK DIAMETER PAF ANCHORS (HILTI X-U, POWERS CSI, OR APPROVED EQUAL) ON A 1:1 SUBSTITUTION BASIS. MINIMUM EMBEDMENT
DEPTH SHALL BE 1.25" WHEN INSTALLED INTO CONCRETE OR GROUTED MASONRY. FOLLOW
MANUFACTURER'S INSTALLATION RECOMMENDATIONS, MINIMUM EDGE DISTANCES, AND PLACEMENT
LIMITATIONS (RELATIVE TO MORTAR JOINTS IN MASONRY).
6. MINIMUM EMBEDMENT DEPTH OF 1/4" TAPCONS OR POWERS TAPPER + INSTALLED IN CONCRETE SHALL BE 1.25" AND INSTALLED INTO MASONRY SHALL BE 1.5". SELECT ANCHOR LENGTH AS REQUIRED TO ACHIEVE
THE SPECIFIED MINIMUM EMBEDMENT DEPTH.
5. THE MANUFACTURER'S REPRESENTATIVE SHALL TRAIN INSTALLERS FOR ALL PRODUCTS TO BE USED PRIOR TO COMMENCEMENT OF WORK. ONLY TRAINED INSTALLERS SHALL PERFORM POST INSTALLED ANCHOR INSTALLATION. A RECORD OF TRAINING SHALL BE KEPT ON SITE AND MADE AVAILABLE TO THE
EOR AS REQUESTED.
4. INSTALL ANCHORS IN STRICT ACCORDANCE WITH MANUFACTURER'S PRINTED INSTALLATION
INSTRUCTIONS (MPII) IN CONJUNCTION WITH EDGE DISTANCE, SPACING, AND EMBEDMENT SPECIFIED ON
DRAWINGS.
3. IN SOME CASES OF CRITICAL LOADING OR GEOMETRIC CONDITIONS, ONLY SPECIFIC ANCHORS WILL BE ALLOWED, AS NOTED ON THE DRAWINGS. IN THESE CASES, THE SPECIFIED BRAND AND MODEL OF
ANCHOR MUST BE USED.
2. TYPE OF ANCHOR SHALL BE AS SPECIFIED ON THE DRAWINGS, WHILE BRAND AND MODEL OF ANCHOR MAY BE SELECTED FROM THE ABOVE LISTED ANCHORS. SUBSTITUTION ANCHORS MUST BE SUBMITTED TO THE ENGINEER FOR REVIEW AND APPROVED IN WRITING BY THE ENGINEER OF RECORD PRIOR TO USE.
ICC-ES REPORTS FOR PROPOSED ANCHOR SUBSTITUTES MUST BE SUBMITTED TO EOR FOR REVIEW. EOR
MAY REQUEST ENGINEERED CALCULATIONS FOR REVIEW AND APPROVAL.
1. SHALL BE EITHER HEAVY DUTY CONCRETE SCREW ANCHOR (SUCH AS POWERS WEDGE-BOLT +, SIMPSON TITEN HD, OR HILTI HUS-H) OR WEDGE TYPE EXPANSION ANCHOR (SUCH AS POWERS POWER-STUD+SD1, SIMPSON WEDGE-ALL, OR HILTI KWIK BOLT 3).
3602 MECHANICAL ANCHORS
APPLY FIREPROOFING TO STEEL STRUCTURE CALCULATING THE THICKNESS OF FIREPROOFING BY COMPARING THE ACTUAL MEMBER SIZE TO THE MEMBER SIZE USED IN THE DESIGNATED UL RATING AND
ADJUSTING APPROPRIATELY.
THE CAMBER OF STEEL MEMBERS SHALL BE VERIFIED IN THE SHOP AND THE FIELD. WHEN NO CAMBER IS
INDICATED, TURN THE MEMBER NATURAL CAMBER UP.
LENGTH OF SHEAR STUD CONNECTIONS IN COMPOSITE SLABS SHALL EQUAL THE DEPTH OF THE
COMPOSITE DECK PLUS 2" (U.N.O.).
SIZE AND SPACING OF CONDUITS IN COMPOSITE SLABS SHALL COMPLY WITH THE REQUIREMENTS OF ASCE
3-91 UNLESS NOTED OTHERWISE ON DRAWINGS.
9. COMPOSITE FLOOR MEMBERS ARE DESIGNED TO BE UNSHORED UNLESS OTHERWISE NOTED. THE WEIGHT OF THE WET CONCRETE WILL RESULT IN DEFLECTIONS OF THE SUPPORTING STEEL DECK, BEAMS, AND GIRDERS. ALL OVERRUNS OF CONCRETE QUANTITIES ARE TO BE ANTICIPATED AND INCLUDED IN THE
CONTRACTOR'S BID. THE CONTRACTOR SHALL COORDINATE EMBEDDED ITEMS REQUIRED FOR
ARCHITECTURAL, STRUCTURAL, AND MECHANICAL ELEMENTS. CONCRETE FLOORS UTILIZING UNSHORED
CONSTRUCTION SHALL BE SCREEDED LEVEL.
8. GROUT UNDER BEARING PLATES SHALL BE NON-METALLIC, NON-SHRINK TYPE WITH A COMPRESSIVE
STRENGTH OF AT LEAST 5,000 PSI IN 28 DAYS.
7. ALL STRUCTURAL STEEL EXPOSED TO EXTERIOR CONDITIONS SHALL BE HOT DIPPED GALVANIZED PER ASTM A123 AND ALL FASTENERS AND HARDWARE SHALL BE HOT DIPPED GALVANIZED PER ASTM A153.
6. WHERE FULLY PRETENSIONED OR SLIP CRITICAL BOLTS ARE REQUIRED, TIGHTENING SHALL BE ACHIEVED USING EITHER TWIST-OFF TENSION CONTROL BOLTS OR DIRECT TENSION INDICATING WASHERS.
5. BOLTS SHARING LOAD WITH WELDS IN A CONNECTION SHALL BE FULLY PRETENSIONED AND SLIP CRITICAL.
4. HIGH STRENGTH BOLTS IN BEARING CONDITION SUPPORTING SIMPLE SPAN BEAMS NOT SUBJECT TO AXIAL LOADS MAY BE INSTALLED TO "SNUG TIGHT" CONDITION IF NORMAL, OR SHORT SLOTTED HOLES ARE USED.
THE ENGINEER OF RECORD WILL BE THE ULTIMATE AUTHORITY IN THE USE OF "SNUG TIGHT" BOLTS. IF LONG SLOTTED OR OVERSIZED HOLES ARE USED, BOLTS MUST BE FULLY PRETENSIONED AND SLIP CRITICAL. PROPER SURFACE PREPARATION IS REQUIRED FOR SLIP CRITICAL BOLTS, INCLUDING OMISSION
OF PRIMER OR FIRE PROOFING, AS APPROPRIATE.
F. DETAIL MOMENT CONNECTIONS AS SHOWN IN THE DETAILS. IF NO DETAIL IS PROVIDED, DETAIL
MOMENT CONNECTION USING FULL PENETRATION WELDS AT BEAM FLANGES.
E. FOR THE PURPOSE OF CORRECTLY INTERPRETING THE CONNECTION SCHEDULES, GIRDERS SHALL BE CONSIDERED AS ANY FLOOR OR ROOF BEAM WHICH CARRIES OTHER FLOOR OR ROOF BEAMS, OR ANY
FLOOR OR ROOF BEAM WHICH CARRIES STEEL COLUMNS.
D. DETAIL FLOOR AND ROOF FRAMING CONNECTIONS FOLLOWING THE REQUIREMENTS SHOWN IN THE TYPICAL CONNECTION SCHEDULES SHOWN IN THESE DRAWINGS, BASED ON THE BEAM OR GIRDER SIZE.
C. FIELD CONNECTIONS SHALL BE BOLTED, EXCEPT AS NOTED OTHERWISE.
B. WELDING ELECTRODES SHALL BE PER AWS D1.1. RETURN FILLET WELDS FOR FRAMED CONNECTIONS
1/2" AT EACH END.
A. BOLTS SHALL BE HIGH-STRENGTH, BEARING TYPE IN SNUG TIGHT CONDITION, U.N.O. TIGHTEN BY AN
AISC APPROVED METHOD.
3. CONNECTIONS:
SHEAR STUD CONNECTORS ASTM A108 (Fu=65 KSI)
ANCHOR RODS ASTM F1554 GR. 36 (Fy=36 KSI)
DIRECT-TENSION-INDICATOR WASHERS ASTM F959
HARDENED STEEL WASHERS ASTM F436
HEAVY HEX NUTS ASTM A563
THREADED RODS ASTM A36 (Fy=36 KSI)
TWIST-OFF TENSION CONTROL BOLTS ASTM F1852
HIGH STRENGTH BOLTS ASTM A325 OR A490
ROUND HSS ASTM A500, GRADE B (Fy=42...
RECTANGULAR HSS ASTM A500, GRADE B (Fy=46...
PIPE ASTM A53, GRADE B (Fy=35 KSI)
ANGLES, CHANNELS AND PLATES ASTM A36 (Fy=36 KSI)
HP SHAPES ASTM A572 (Fy=50 KSI)
S AND M SHAPES ASTM A36 (Fy=36 KSI)
WIDE FLANGE SHAPES ASTM A992 (Fy=50 KSI)
2. MATERIAL SHALL CONFORM TO THE FOLLOWING, EXCEPT AS NOTED:
1. STEEL WORK SHALL BE NEW AND CONFORM TO THE ANSI/AISC 360-10 SPECIFICATION FOR STRUCTURAL
STEEL BUILDINGS.
5120 STRUCTURAL STEEL
5. PROVIDE FILLET WELDS AT CONTACT POINTS BETWEEN STEEL MEMBERS SUFFICIENT TO DEVELOP THE ALLOWABLE TENSILE STRENGTH OF THE SMALLER MEMBER AT THE JOINT UNLESS DETAILED OTHERWISE
ON THE DRAWINGS. THE MINIMUM FILLET WELD SIZE IS 3/16" UNLESS OTHERWISE NOTED.
4. UNLESS NOTED OTHERWISE ON THE DRAWINGS, GROOVE WELDS SHALL BE FULL PENETRATION.
3. FULL PENETRATION GROOVE WELDS SHALL BE INSPECTED BY ULTRASONIC TESTING. TWENTY-FIVE
PERCENT OF THE WELDS SHALL BE INSPECTED AT RANDOM UNLESS NOTED OTHERWISE. SEE
SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
2. WELDS SHOWN ON STRUCTURAL DRAWINGS ARE MINIMUM DESIGN REQUIREMENTS. THE FABRICATOR'S
SHOP DRAWINGS SHALL REFLECT WELDS IN ACCORDANCE WITH AWS REQUIREMENTS.
1. WELDING SHALL BE DONE BY WELDERS WITH CURRENT CERTIFICATION IN ACCORDANCE WITH AWS D1.1.
5122 WELDING
9. SUBMIT SHOP DRAWINGS SHOWING PLACEMENT OF SHEAR CONNECTORS FOR ENGINEER'S APPROVAL.
8. WHERE STEEL DECK CORRUGATIONS DO NOT ALLOW FOR AN EVEN SPACING OF SHEAR CONNECTORS WITH ONE STUD IN EACH FLUTE, ADDITIONAL STUDS IN A SECOND ROW (AND THIRD ROW WHERE REQUIRED) SHALL BE PLACED SUCH THAT THE HIGHEST DENSITY OF SHEAR CONNECTORS OCCURS NEAR
THE BEAM SUPPORT.
7. SHEAR CONNECTORS SHALL BE PLACED IN A SINGLE ROW DIRECTLY OVER THE BEAM WEB, WHENEVER POSSIBLE. STUDS SHALL BE PLACED IN TWO OR THREE ROWS ONLY WHERE REQUIRED IN ORDER TO
PLACE THE TOTAL NUMBER OF STUDS.
B. BEAMS PARALLEL TO DECK SPAN = (8 X TOTAL SLAB THICKNESS)
A. BEAMS PERPENDICULAR TO DECK SPAN = 36"
6. MAXIMUM SPACING OF SHEAR CONNECTORS SHALL BE AS FOLLOWS:
5. UNLESS NOTED OTHERWISE ON PLANS, SHEAR CONNECTORS SHALL BE EQUALLY DISTRIBUTED ALONG
THE LENGTH OF BEAM.
4. SEE PLANS FOR SPECIFIED NUMBER OF SHEAR CONNECTORS.
3. STUDS SHALL BE TYPE 'B', HEADED STUDS HAVING A MINIMUM TENSILE STRENGTH OF 65,000 PSI. AND
SHALL BE OF LENGTH AND DIAMETER SHOWN ON STRUCTURAL DRAWINGS.
2. ATTACHMENT OF STUDS SHALL BE SUFFICIENT TO DEVELOP THE FULL CAPACITY OF EACH INDIVIDUAL
STUD.
1. SHEAR STUD CONNECTORS SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH AWS D1.1
"STRUCTURAL WELDING CODE", SECTION 7 - STUD WELDING.
5124 SHEAR STUD CONNECTORS
10. CONDUIT SHALL BE ADEQUATELY FASTENED TO DECK TO PREVENT SHIFTING DURING CONCRETE POUR.
9. DO NOT RUN CONDUIT CONTINUOUSLY IN DECK FLUTES.
8. CONDUIT IN CONCRETE SLAB ON METAL DECK SHALL NOT BE SPACED CLOSER THAN 6" O.C. MINIMUM.
7. MAINTAIN 2" MINIMUM COVER OVER CONDUIT AT ALL TIMES, INCLUDING LOCATIONS WHERE CONDUITS
CROSS EACH OTHER. CONDUITS SHALL CROSS AT 90 DEGREES TO EACH OTHER.
6. CONDUIT LOCATED IN SLAB ON METAL DECK SHALL BE NO GREATER THAN 3/4" DIA. AND SHALL BE
GALVANIZED STEEL CONDUIT.
5. BUTTON PUNCHING OF SIDE LAPS IS NOT PERMITTED.
4. SIDE LAPS BETWEEN DECKS SHALL BE WELDED OR FASTENED USING #10 TEK SCREWS AT A MAXIMUM
SPACING OF 36 INCHES, WITH NO LESS THAN 2-#10 TEKS SCREWS PER SIDE LAP SPAN.
3. PROVIDE 5/8" DIAMETER PUDDLE WELDS IN A 36/4 PATTERN AT SUPPORTS, AND AT 12" C/C ALONG EDGE
SUPPORTS.
2. DECK SHALL HAVE DEFORMATIONS TO PROVIDE ADEQUATE MECHANICAL INTERLOCKING BETWEEN DECK
AND CONCRETE FOR COMPOSITE ACTION.
1. SHALL BE GALVANIZED (G60), CORRUGATED STEEL COMPOSITE DECK OF GAGE AND DEPTH INDICATED ON DRAWINGS, CONFORMING TO STEEL DECK INSTITUTE SPECIFICATION FOR COMPOSITE FLOOR DECK.
5310 COMPOSITE STEEL DECK
17. LIGHT GAGE FRAMING CONNECTORS SPECIFIED BY PART NUMBER OR MODEL NAME ARE STANDARD CONNECTORS FABRICATED BY THE STEEL NETWORK (TSN), RALEIGH, N.C., 888-474-4876. CONNECTORS SHALL BE INSTALLED PER THE REQUIREMENTS OF THE LIGHT STEEL FRAMING CONNECTIONS CATALOG (LATEST EDITION) BY THE STEEL NETWORK, USING THE NUMBER/SIZE OF FASTENERS SHOWN IN THESE DRAWINGS. WHERE NUMBER/SIZE IS NOT SHOWN IN THESE DRAWINGS, USE THE FASTENERS SPECIFIED IN THE CATALOG TO OBTAIN THE MAXIMUM CAPACITY OF THE SPECIFIED CONNECTOR. SUBSTITUTION OF GENERIC BENT PLATE LIGHT GAGE CONNECTORS IS NOT ALLOWED WITHOUT DESIGN CALCULATIONS SHOWING EQUAL OR BETTER CAPACITY TO THE SPECIFIED TSN CONNECTOR, PREPARED AND SIGNED AND SEALED BY A FLORIDA REGISTERED ENGINEER EXPERIENCED IN LIGHT GAGE STEEL CONNECTION
DESIGN.
16. LATERAL BRACING SHALL BE PROVIDED BY USE OF PLYWOOD SHEATHING, GYPSUM SHEATHING, OR BY HORIZONTAL STRAPS OR COLD-ROLLED CHANNELS. BRACING SHALL CONFORM TO SECTION D3 OF THE
AISI SPECIFICATIONS.
15. BRIDGING TO BE SUPPLIED AND INSTALLED PER CFS STUD MANUFACTURER RECOMMENDATIONS (5'-0"
O.C. MAX AND WITHIN 1'-0" OF DEFLECTION TRACKS).
14. STUDS SHALL SIT SQUARELY IN THE TOP AND BOTTOM RUNNER TRACK WITH FIRM ABUTMENT AGAINST TRACK WEBS. STUDS SHALL BE ALIGNED OR PLUMBED AND SECURELY FASTENED TO THE FLANGES OF
BOTH TOP AND BOTTOM RUNNER TRACK.
13. ATTACHMENT OF COLLATERAL MATERIALS TO STEEL MEMBERS SHALL BE MADE WITH SELF-DRILLING
SCREWS OR HARDENED SCREW SHANK NAILS.
12. WIRE TYING OF FRAMING MEMBERS IN STRUCTURAL APPLICATIONS SHALL NOT BE PERMITTED.
11. JOINING OF STRUCTURAL MEMBERS SHALL BE MADE WITH SELF-DRILLING SCREWS OR WELDING.
10. FRAMING MEMBERS SHALL BE CUT SQUARELY OR AT AN ANGLE AS REQUIRED TO FIT SQUARELY AGAINST
ABUTTING MEMBERS. MEMBERS SHALL BE HELD FIRMLY IN PLACE UNTIL PROPERLY JOINED.
9. REPAIR DAMAGED OR UNCOATED GALVANIZED COATINGS PER ASTM A780.
8. WELDING TO COMPLY WITH COLD-FORMED STEEL ENGINEERS INSTITUTE TECH NOTE 5606-1 - WELDING
COLD-FORMED STEEL.
7. TOLERANCES TO COMPLY WITH ASTM C955.
6. SUBMIT PROPOSED LIGHT GAGE CFS MANUFACTURERS DATA AND LOAD TABLES FOR REVIEW.
5. ATTACHMENTS, CLOSURES, HARDWARE, ETC., SHALL BE AS SHOWN AND/OR IN ACCORDANCE WITH THE
MANUFACTURERS RECOMMENDATIONS.
4. STRUCTURAL LIGHT GAGE CFS FRAMING AND THEIR CONNECTIONS SHALL BE AS DEPICTED ON THE
STRUCTURAL PLANS AND DETAILS.
3. MINIMUM STEEL GRADES (FY): 12 GA (97 MILS), 14 GA (68 MILS); 16 GA (54 MILS) STUDS AND TRACK: 50 KSI;
18 GA (43 MILS), 20 GA (33 MILS) STUDS AND TRACK: 33 KSI.
2. STEEL STUDS, JOISTS, LINTELS, AND RUNNER TRACK MEMBERS SHALL BE OF TYPE SHOWN ON THE DRAWINGS AND SPECIFICATIONS CONFORMING TO ASTM A-446 GRADE C WITH HOT DIPPED GALVANIZED
COATING CONFORMING TO ASTM A525 (CLASS G90).
1. ALL COLD FORMED STEEL FRAMING SHALL CONFORM TO THE AISI/COFS/NASPEC 2010 NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS WITH SUPPLEMENT NO. 2, THE AISI MANUAL COLD-FORMED STEEL DESIGN (2007 EDITION), AISI CODE OF STANDARD PRACTICE FOR COLD-FORMED STEEL STRUCTURAL FRAMING (2007 EDITION), AISI/COFS/GP-2007 STANDARD FOR COLD-FORMED STEEL FRAMING - GENERAL PROVISIONS (2007 EDITION) AND COLD-FORMED STEEL
ENGINEERS INSTITUTE (CFSEI) PUBLICATIONS, AS MODIFIED OR CLARIFIED HEREIN.
5400 STRUCTURAL COLD-FORMED STEEL (CFS) FRAMING
7. SHOP DRAWINGS AND CALCULATIONS SHALL BE SIGNED AND SEALED BY AN ENGINEER REGISTERED IN
THE STATE OF FLORIDA.
6. SHOP DRAWINGS SHALL SHOW AND SPECIFY CONNECTIONS UTILIZED WITHIN THE STEEL STAIR SYSTEM AS WELL AS CONNECTIONS TO AND LOADS IMPOSED UPON THE STRUCTURAL SYSTEM SHOWN ON THESE
DRAWINGS.
5. THE LOADS SHALL BE CLEARLY INDICATED ON SHOP DRAWINGS.
4. STEEL STAIR SYSTEM AND CONNECTIONS SHALL BE DESIGNED FOR APPLICABLE LOADS AS INDICATED ON THE DRAWINGS AND IN THE FLORIDA BUILDING CODE, 6th EDITION (2017)/2012 INTERNATIONAL BUILDING
CODE.
3. THE ENGINEERED STAIR SYSTEM SHALL INCLUDE THE STAIRS, LANDINGS, SUPPORT FRAMING, POSTS, HANGERS, AND CONNECTIONS TO THE BUILDING STRUCTURE, UNLESS NOTED OTHERWISE.
CONNECTIONS TO THE BUILDING STRUCTURE SHALL BE COMPATIBLE WITH THE STRUCTURE SHOWN ON
THE CONTRACT DRAWINGS.
2. THE CONFIGURATION OF THE STEEL STAIR SYSTEM SHALL BE AS SHOWN ON THE ARCHITECTURAL
DRAWINGS.
1. ENGINEERED STEEL STAIR SYSTEM AND CONNECTIONS OF SAME TO THIS STRUCTURE SHALL BE
DESIGNED BY AN ENGINEER REGISTERED IN THE STATE OF FLORIDA.
5714 STEEL STAIRS
9. AUGERCAST PILE CAPACITIES (UNFACTORED): 75 TONS COMPRESSION, 45 TONS TENSION, 3.75 TONS
LATERAL.
8. WHERE THE PILE CUTOFF IS NEAR THE SURFACE OR ABOVE THE BOTTOM OF THE EXCAVATION. METAL SLEEVES OR CASING OF THE PROPER DIAMETER AND AT LEAST 18 INCHES IN LENGTH SHALL BE PLACED AROUND THE PILE TOPS. (SPECIAL CONDITIONS MAY REQUIRE METAL SLEEVES OF ADDITIONAL LENGTH.)
7. CONTRACTOR IS RESPONSIBLE FOR ENGINEERING COSTS ASSOCIATED WITH REDESIGNS CAUSED BY
IMPROPER PILE LOCATIONS.
6. AN AS-BUILT SURVEY OF PILE LOCATIONS SHALL BE PERFORMED BY A FLORIDA REGISTERED LAND SURVEYOR. PILES SHALL BE LOCATED ON THE AS-BUILT DRAWINGS HORIZONTALLY AND VERTICALLY FROM THE COLUMN CENTERLINES. SUBMIT THE AS-BUILT DRAWINGS TO THE STRUCTURAL ENGINEER
FOR APPROVAL.
5. ADJACENT PILES SHALL NOT BE PLACED UNTIL THE GROUT IN THE PILES HAS SET FOR 24 HOURS IN ORDER THAT THERE WILL BE NO INTER CONNECTION BETWEEN ADJACENT PILES WHILE THE GROUT IS IN
A FLUID STATE.
4. GROUT SHALL BE TESTED IN ACCORDANCE WITH ASTM STANDARDS UTILIZING 2" X 2" CUBES. CUBES
SHALL BE MADE AND CURED IN ACCORDANCE WITH ASTM C109.
3. GROUT SHALL BE PER AN APPROVED MIX DESIGN PROPORTIONED TO ACHIEVE A STRENGTH AT 28 DAYS OF 4000 PSI. GROUT SHALL HAVE A MAXIMUM FLOW RATE OF 15 SECONDS. SUBMIT PROPOSED MIX
DESIGN WITH RECENT FIELD OR LAB CYLINDER TESTS FOR REVIEW PRIOR TO USE.
2. PILES SHOULD BE REINFORCED AS INDICATED IN TYPICAL PILE CAP DETAILS ON SJ-506.
1. AUGERCAST PILING SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE GEOTECHNICAL RECOMMENDATIONS AND INSTALLATION PROCEDURES CONTAINED IN THE FOLLOWING GEOTECHNICAL
REPORT REFERENCED ABOVE.
3163 AUGER CAST PILES
B. DESIGN OF THE CONNECTION BETWEEN THE STOREFRONT AND PUNCHED WINDOW FRAMES AND THE
STRUCTURE OR SUPPORTING ELEMENT IS BY THE STOREFRONT/PUNCHED WINDOW CONTRACTOR.
A. FRAMES FOR STOREFRONT AND PUNCHED WINDOWS ARE TO SPAN VERTICALLY TO THE STRUCTURE
ABOVE OR BELOW THE FRAME.
3. STOREFRONT AND PUNCHED WINDOWS
C. SEE THE TYPICAL PERIMETER SUPPORT DETAIL FOR MISCELLANEOUS STEEL REQUIRED AT THE
GRAVITY AND LATERAL SUPPORT LOCATIONS.
B. DESIGN OF THE CONNECTION BETWEEN CURTAIN WALL AND STRUCTURE OR SUPPORTING ELEMENT
IS BY THE CURTAIN WALL CONTRACTOR.
A. CURTAIN WALL IS TO SPAN VERTICALLY WITH GRAVITY AND LATERAL SUPPORTS LOCATED AT EACH
FLOOR.
2. CURTAIN WALL
THE CURTAIN WALL SYSTEM, STOREFRONT, SUNSCREEN, AND PUNCHED WINDOWS ARE TO BE
DESIGNED/ENGINEERED FOR WIND AND GRAVITY LOADS BY THE MANUFACTURER. THIS INCLUDES THE
DESIGN OF THE ELEMENT AND THE CONNECTION TO THE STRUCTURE OR SUPPORTING ELEMENT.
1. GENERAL
8000 EXTERIOR OPENINGS
6. THE CONTRACTOR SHALL BEAR THE COST OF CORRECTING OR REPLACING ALL MATERIALS, SYSTEMS, COMPONENTS, AND/OR WORK THAT DO NOT MEET THE REQUIREMENTS OF THE SPECIAL INSPECTOR.
5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING AND SCHEDULING ALL SPECIAL
INSPECTIONS.
J. FOUNDATIONS - CAST DEEP ELEMENTS
I. FOUNDATIONS - SOIL
H. POST INSTALLED ANCHORS
G. MASONRY
F. REINFORCING STEEL
E. CAST-IN-PLACE CONCRETE
D. COLD-FORMED STEEL
C. METAL/DECK
B. WELDING/BOLTING
A. STRUCTURAL STEEL
4. IN ACCORDANCE WITH CHAPTER 17 OF THE 2015 INTERNATIONAL BUILDING CODE, SPECIAL INSPECTIONS
ARE REQUIRED FOR THE FOLLOWING MATERIALS, SYSTEMS, COMPONENTS, AND/OR WORK:
3. FREQUENCY AND SCOPE OF SPECIAL INSPECTIONS SHALL BE IN ACCORDANCE WITH THE CONTRACT SPECIFICATIONS AND CHAPTER 17 OF THE 2015 INTERNATIONAL BUILDING CODE. SEE SHEET SA-005 FOR
ADDITIONAL INFORMATION.
2. SPECIAL INSPECTION REPORTS SHALL BE SUBMITTED TO THE BUILDING OFFICIAL, EOR, AND OWNER FOR
RECORD.
1. SPECIAL INSPECTIONS SHALL BE PERFORMED BY ONE OR MORE AGENCIES APPROVED BY THE VA
RESIDENT ENGINEER.
1070 SPECIAL INSPECTIONS
B. ALUMINUM SUNSCREENS ARE PREFABRICATED ELEMENTS BY THE SUNSCREEN CONTRACTOR THAT RESIST THE WIND LOAD CRITERIA INDICATED IN THESE PLANS IN ADDITION TO SELF WEIGHT.
A. DESIGN OF THE CONNECTION BETWEEN THE SUNSCREEN AND THE SUPPORTING STRUCTURAL ELEMENT
IS BY THE SUNSCREEN CONTRACTOR.