Attachment 14 - Asbestos Survey Report.pdf
PDF 5 MB Posted
- Attached to
- Y1AZ--36C77621B0013 - Construct Administration Bldg. POD 1A (Minor) - Gainesville Federal contract opportunity
- Solicitation number
- 36C77621B0013
About this file
This solicitation seeks proposals for the construction of a new 26,000 square foot administration building at the Malcom Randall VA Medical Center in Gainesville, Florida. The scope of work includes architectural, site, structural, fire protection, HVAC, plumbing, electrical, earthwork, exterior utilities, and other construction aspects as required by the contract drawings and specifications. The work also involves demolition of existing architectural, site, plumbing, fire protection, mechanical and electrical infrastructure. The Department of Veterans Affairs, through the Veterans Health Administration Program Contracting Activity Central, intends to award a single firm-fixed-price contract for the design-bid-build project. Construction is to take place adjacent to the existing CLC building 12 and north of SW 16th avenue at the Malcom Randall VA Medical Center located at 1601 SW Archer Road in Gainesville, Florida.
View the file
Other files for this federal contract opportunity
Show all 32
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
2228 NW 40th Terrace, Suite C Gainesville, Florida 32605
352-335-6648 • Fax 352-335-6187
ASBESTOS SURVEY REPORT
Chiller Area – Section “M,” Buildings 12, T1, T1A, T3, T7, T8, T9, T10, B26, B27 & Shed
Project VA248-16-R-0441 Malcom Randall VA Medical Center
1601 SW Archer Road Gainesville, Florida 32608-1197
GLE Project No.: 18950-00483
Prepared for:
Mr. Douglas Sangster, AIA, CGC President
Alliance Design & Construction, Inc.
P.O. Box 1296
Winter Park, Florida 32790
June 2018
Prepared by:
GLE Associates, Inc.
2228 NW 40th Terrace, Suite C | Gainesville, Florida 32605 | 352-335-6648 | Fax: 352-335-6187
Tampa | Orlando | Ft. Lauderdale | Miami | Jacksonville | Atlanta | Nashville Architecture AA 0002369 Engineer CA 5483 Asbestos ZA 0000034 Geology GB 0000297
June 20, 2018
Mr. Douglas Sangster, AIA, CGC via e-mail: dsangster@alliance-dci.com President Alliance Design & Construction, Inc.
P.O. Box 1296 Winter Park, Florida 32790
RE: Asbestos Survey Report
Chiller Area – Section “M,” Buildings 12, T1, T1A, T3, T7, T8, T9, T10, B26, B27 & Shed Project VA248-16-R-0441 Malcom Randall VA Medical Center 1601 SW Archer Road Gainesville, Florida 32608-1197
GLE Project No.: 18950-00483
Dear Mr. Sangster:
GLE Associates, Inc. (GLE) performed a survey for asbestos-containing materials (ACM) on May 14, 2018 through May 16, 2018 at Malcom Randall VA Medical Center, located in Gainesville, Florida. The survey was performed by Mr. Cullen Schmitz and Mr. Michael Harrell with GLE. This report outlines the sampling and testing procedures, and presents the results along with our conclusions and recommendations.
GLE appreciates the opportunity to serve as your consultant on this project. If you should have any questions, or if we can be of further service, please do not hesitate to call.
Sincerely, GLE Associates, Inc.
Cullen Schmitz Robert B. Greene, PE, PG, CIH, LEED AP Junior Project Manager President
Florida LAC# EA 0000009 CS/MDH/RBG/lr
G:\Work\Asbestos\'18\18950-VA\00483-Bldgs 12, T1, T1A, T3, T7, T8, T9, T10, B26, B27 & Shed\Reports\Asbestos\Asbestos Survey Report.doc
TABLE OF CONTENTS
1.0 INTRODUCTION 1
1.1 Introduction 1
1.2 Facility Description 1
2.0 RESULTS 6
2.1 Asbestos Survey Procedures 6
2.2 Identified Suspect Asbestos-Containing Materials 7
Table 2.2-1 through 9 — Summary of Homogeneous Sampling Areas
3.0 CONCLUSIONS AND RECOMMENDATIONS 19
3.1 General 19
3.2 Specific 20
4.0 LIMITATIONS AND CONDITIONS 21
APPENDICES
Appendix A – Analytical Results and Chain of Custody Appendix B – Personnel and Laboratory Certifications Appendix C – Photographs
1.0 INTRODUCTION
1.1 INTRODUCTION
The purpose of this survey was to identify accessible asbestos-containing materials (ACMs) and their general locations within Buildings 12, T1, T1A, T3, T7, T8, T9, T10, B26, B27 and Shed, located at Malcom Randall VA Medical Center, in Gainesville, Florida. The scope of the survey was limited to the chiller area of “Section ‘M’,” the tunnel associated with the chiller area, the tunnel from the CLC (Building 12) to the main building, the second floor walkway of the CLC, the second floor northwest of the CLC associated with planned tie-ins (consisting of Rooms 212- 12 through 220-12 and associated corridors and NW balcony), the ground floor west entrance to the CLC (and adjacent Rooms 101-12, 101A-12, 130B-12, and associated corridor), and the trailers and outbuildings listed above. The scope of the survey did not include roofing materials, at the request of the property owner. At the time of the survey, Room 130B-12 of the CLC was inaccessible. Additionally, Rooms 104 and 106 of Trailer T1, the AFGE Union areas of Trailer T3, Rooms 112 and 113 of Trailer T7, offices on the west of Trailer T10, the conference room of Trailer T10, the south closet of Trailer T10, and the interior of the police storage shed were inaccessible at the time of the survey. The survey was conducted pursuant to National Emission Standards for Hazardous Air Pollutants (NESHAP, 40 CFR 61) requirements, associated with the scheduled plans. The survey was performed on May 14, 2018 through May 16, 2018, by Mr.
Cullen Schmitz and Mr. Michael Harrell, Environmental Protection Agency/Asbestos Hazard Emergency Response Act (EPA/AHERA) accredited inspectors. The scope of this survey did not include demolition of any building components, evaluation of architectural plans, or the quantification of materials for abatement purposes, or removal cost estimating.
1.2 FACILITY DESCRIPTION
A summary of the facility investigated is outlined in the table below. A representative view of the facility is shown in Appendix C.
Chiller Area – Section “M”
Facility Type: Commercial Construction Date: Unknown Number of Floors: One
Exterior Floor Support: Concrete Floor Wall Support: Concrete Masonry Units Exterior Finish: Brick Roof System Type: Not in Scope
Interior Wall Substrate: Concrete Masonry Units Wall Finishes: Paint Floor Finishes: None Ceiling System: Concrete Deck
Building 12 – CLC Facility Type: Hospital, Residential Construction Date: Unknown Number of Floors: Two In Scope
Exterior Floor Support: Concrete Floor Wall Support: Concrete Masonry Units Exterior Finish: Paint Roof System Type: Not In Scope
Interior Wall Substrate: Drywall and Joint Compound Wall Finishes: Paint, Wallpaper, Cove Base Floor Finishes: Vinyl Floor Tile, Ceramic Tile Ceiling System: Suspended Ceiling System Ceiling Finishes: Suspended Ceiling Tiles
B26 & B27
Facility Type: Storage Construction Date: Unknown Number of Floors: One
Exterior Floor Support: Grate Wall Support: Metal Framing Exterior Finish: Metal Siding Roof System Type: Not In Scope
Interior Wall Substrate: Metal Container Wall Finishes: Paint Floor Finishes: None Ceiling System: Metal Ceiling Finishes: Paint
T1
Facility Type: Administration Construction Date: Unknown Number of Floors: One
Exterior Floor Support: Raised Wood Floor Wall Support: Wood Framing Exterior Finish: Metal Siding Roof System Type: Not In Scope
Interior Wall Substrate: Drywall Wall Finishes: Wallpaper, Cove Base Floor Finishes: Vinyl Floor Tile, Carpet
T1A
Construction Date: Unknown Number of Floors: One
Exterior Floor Support: Raised Wood Floor Wall Support: Wood Framing Exterior Finish: Metal Siding Roof System Type: Not In Scope
Interior Wall Substrate: Drywall Wall Finishes: Wallpaper, Cove Base Floor Finishes: Vinyl Floor Tile, Carpet
T3
Construction Date: Unknown Number of Floors: One
Exterior Floor Support: Raised Wood Floor Wall Support: Wood Framing Exterior Finish: Metal Siding Roof System Type: Not In Scope
Interior Wall Substrate: Drywall Wall Finishes: Wallpaper, Cove Base Floor Finishes: Vinyl Floor Tile
T7
Facility Type: Administration, Law Enforcement Construction Date: Unknown Number of Floors: One
Exterior Floor Support: Raised Wood Floor Wall Support: Wood Framing Exterior Finish: Metal Siding Roof System Type: Not In Scope
Interior Wall Substrate: Drywall Wall Finishes: Wallpaper, Cove Base Floor Finishes: Vinyl Floor Tile
T8
Construction Date: Unknown Number of Floors: One
Exterior Floor Support: Raised Wood Floor Wall Support: Wood Framing Exterior Finish: Metal Siding Roof System Type: Not In Scope
Interior Wall Substrate: Drywall Wall Finishes: Paint, Wallpaper, Cove Base Floor Finishes: Vinyl Floor Tile
Shed
Facility Type: Storage Construction Date: Unknown Number of Floors: One
Exterior Floor Support: Concrete Floor, Raised Wood Floor Wall Support: Wood Framing Exterior Finish: Metal Siding Roof System Type: Not In Scope
Interior Wall Substrate: Inaccessible Wall Finishes: Inaccessible Floor Finishes: Inaccessible Ceiling System: Inaccessible Ceiling Finishes: Inaccessible
T9
Construction Date: Unknown Number of Floors: One
Exterior Floor Support: Raised Wood Floor Wall Support: Wood Framing Exterior Finish: Metal Siding Roof System Type: Not In Scope
Interior Wall Substrate: Drywall Wall Finishes: Paint, Wallpaper, Cove Base Floor Finishes: Vinyl Floor Tile
T10
Construction Date: Unknown Number of Floors: One
Exterior Floor Support: Raised Wood Floor Wall Support: Wood Framing Exterior Finish: Metal Siding Roof System Type: Not In Scope
Interior Wall Substrate: Drywall Wall Finishes: Paint, Wallpaper, Cove Base Floor Finishes: Carpet, Floor Tile
2.0 RESULTS
2.1 ASBESTOS SURVEY PROCEDURES
The survey was performed by visually observing accessible areas of the building. EPA/AHERA accredited inspectors performed the visual observations (refer to Appendix B for personnel qualifications).
After the overall visual survey was completed, representative sampling areas were determined.
The surveyors delineated homogeneous areas of suspect materials and samples of each material were obtained, in general accordance with regulations as established by the Occupational Safety and Health Administration (OSHA) and NESHAP. The field surveyors determined sample locations based on previous experience. Both friable and non-friable materials were sampled. A friable material is one that can be crushed when dry by normal hand pressure. This survey did not include the demolition of building components to access suspect material.
After completion of the fieldwork, the samples were delivered to GLE’s National Voluntary Laboratory Accreditation Program (NVLAP) accredited laboratory for analysis. The samples were analyzed by Polarized Light Microscopy (PLM) coupled with dispersion staining, in general accordance with EPA-600/R-93/116. Utilizing this procedure, the various asbestos minerals (chrysotile, amosite, crocidolite, actinolite, tremolite, and anthophyllite) can be determined. The percentages of asbestos minerals in the samples were visually determined by the microscopist. Please note that the EPA designates all materials containing greater than 1% asbestos as an “asbestos-containing material” (ACM).
Regulated Asbestos-Containing Material (RACM) is defined as (a) Friable asbestos materials,
(b) Category I non-friable ACM that has become friable, (c) Category I non-friable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading, or (d) Category II non-friable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the material in the course of demolition or renovation operations regulated by this subpart.
Category I and Category II non-friable ACM, as defined by the EPA:
Category I non-friable ACM means asbestos containing packings, gaskets, resilient floor covering, asphalt roofing products, and pliable sealants and mastics that are in good condition and not friable, containing more than 1 percent asbestos, as determined using the method specified in Appendix E, Subpart E, 40 CFR Part 763, Section 1, PLM.
Category II non-friable ACM means any material, excluding Category I non-friable ACM, containing more than 1 percent asbestos as determined using the methods specified in Appendix E, Subpart E, 40 CFR Part 763 Section 1, PLM that, when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure.
2.2 IDENTIFIED SUSPECT ASBESTOS-CONTAINING MATERIALS
A total of 219 samples of suspect building materials were collected from the facility during the survey, representing 73 different identified homogeneous areas. No suspect building materials were observed in B26 and B27. The results of the laboratory analyses are included in Appendix A. Photographs of the various materials sampled are included in Appendix C.
Due to the damage that could be caused by destructive sampling techniques and restricted accessibility, the following materials were assumed to contain asbestos minerals and were not sampled:
1. Locker Doors within the NW of the 2nd Floor of the CLC;
Due to accessibility issues, the following areas were not accessed at the time of the survey.
1. Room 130B-12 of the CLC;
2. Rooms 104 and 106 of Trailer T1;
3. AFGE Union areas of Trailer T3;
4. Rooms 112 and 113 of Trailer T7;
5. Offices on the west of Trailer T10;
6. Conference Room and south closet of Trailer T10;
7. Interior of police storage shed.
Should planned renovation and/or demolition activities involve the disturbance of building materials in these areas, we recommend that they be sampled and analyzed for asbestos content, and if determined to be ACM, be properly removed and disposed by a licensed asbestos abatement contractor prior to conducting such activities.
A summary of the homogenous sampling areas of suspect ACM determined to be present is outlined in the following table.
ASBESTOS CONTENT
Expressed as percent
* = The facility owner has the option of point-counting by polarized light microscopy (PLM) those RACM whose asbestos content is less than 10% in order to more accurately determine the asbestos content therein.
PC = Results based on Point-Count analysis
FRIABILITY F = Friable Material NF = Non-Friable Material
ACM CATEGORY RACM = Regulated ACM CAT I = Category I non-friable ACM CAT II = Category II non-friable ACM
ABBREVIATIONS: NA = Not Applicable ND = None Detected NIS = Not in Scope C = Chrysotile A = Amosite
HA = Homogeneous Area SF = Square Feet LF = Linear Feet CF = Cubic Feet
TABLE 2.2-1: SUMMARY OF HOMOGENEOUS SAMPLING AREAS
CHILLER AREA – SECTION “M”
AND ASSOCIATED TUNNEL
MALCOM RANDALL VA MEDICAL CENTER – GAINESVILLE, FLORIDA
HA # HOMOGENEOUS MATERIAL
DESCRIPTION
HOMOGENEOUS MATERIAL
LOCATION
FRIABILITY
(F /NF)
% ASBESTOS* # OF SAMPLES
COLLECTED
APPROXIMATE
QUANTITY
ACM
CATEGORY
M-01 Red Gaskets Chiller Area – Condensed Water
Lines
NF ND 3 NIS NA
M-02 Black Gaskets Chiller Area – P-4, P-5, P-6 NF ND 3 NIS NA
MAS-01 Brown Mastic Chiller Area – Chillers 1 & 2 NF ND 3 NIS NA
TSI-01 White Mastic on Fiberglass Chiller Area – West of Chiller NF ND 3 NIS NA
TSI-02 White Mastic on Foamglass Chiller Area – Chiller Trunks NF ND 3 NIS NA
TSI-03 White Mastic on Foamglass Chiller Area – North Small Chiller by Ramp
NF ND 3 NIS NA
TSI-04 White Mastic on Foamglass Chiller Area – Southwest Tunnel NF ND 3 NIS NA
TSI-05 White Mastic on Fiberglass Chiller Area – Tunnel Main
Steam/Condensed Lines
NF ND 3 NIS NA
TSI-06 White Mastic on Fiberglass Chiller Area – Tunnel Steam Branch
Points
NF ND 3 NIS NA
TSI-07 White Mastic on Foamglass Chiller Area – Tunnel Chilled Water
Lines
NF ND 3 NIS NA
* = The facility owner has the option of point-counting by polarized light microscopy (PLM) those RACM whose asbestos content is less than 10% in order to more accurately determine the asbestos content therein.
PC = Results based on Point-Count analysis
FRIABILITY F = Friable Material NF = Non-Friable Material
ACM CATEGORY RACM = Regulated ACM CAT I = Category I non-friable ACM CAT II = Category II non-friable ACM
ABBREVIATIONS: NA = Not Applicable ND = None Detected NIS = Not in Scope C = Chrysotile A = Amosite
TABLE 2.2-2: SUMMARY OF HOMOGENEOUS SAMPLING AREAS
BUILDING 12 – CLC
2ND
FLOOR WALKWAY, TUNNEL, NORTHWEST 2ND
FLOOR, AND WEST ENTRANCE
MALCOM RANDALL VA MEDICAL CENTER – GAINESVILLE, FLORIDA
HA # HOMOGENEOUS MATERIAL
DESCRIPTION
HOMOGENEOUS MATERIAL
LOCATION
FRIABILITY
(F /NF)
% ASBESTOS* # OF SAMPLES
COLLECTED
APPROXIMATE
QUANTITY
ACM
CATEGORY
CT-01 2’x2’ White Fissured Ceiling Tile CLC – 2nd Floor Northwest Rooms F ND 3 NIS NA
CT-02
2’x2’ White Fissured Recessed Ceiling
Tile CLC – 1st & 2nd Floor Hall F ND 3 NIS NA
DW-01 Drywall with Joint Compound CLC - 1st Floor West
CLC - 2nd Floor Northwest
NF ND 3 NIS NA
FT-01
12”x12” Beige Speckled Floor Tile with Black Mastic
CLC - 1st & 2nd Floor Northwest Center Corridor and Room
Patches
NF
FT – ND
Black Mastic – 5% C
3 750 SF CAT I
FT-02
12”x12” Dark Tan Floor Tile with
Black Mastic CLC - 1st & 2nd Floor Northwest
Perimeter
NF
FT – 7% C
Black Mastic – 5% C
3 260 SF CAT I
FT-03
12”x12” Light Tan Streaked Floor
Tile with Black Mastic CLC – 2nd Floor Northwest
Rooms
NF
FT – 7% C
Black Mastic – 5% C
3 740 SF CAT I
FT-04
12”x12” White Floor Tile with Tan
Mastic CLC – Rooms 1014-12, 101-12 NF ND 3 NIS NA
M-03 Brown Caulk CLC – 2nd Floor Walkway Doors &
Northwest Windows
NF ND 3 NIS NA
M-04 White Ceramic Tile Grout CLC – 2nd Floor Northwest
Restrooms
NF ND 3 NIS NA
M-05 Gray Caulk CLC – 2nd Floor Northwest Balcony NF ND 3 NIS NA
MAS-02 White Duct Mastic CLC – 2nd Floor Northwest NF 10% C 3 120 SF CAT I
TSI-08 White Mastic on Fiberglass CLC Tunnel – Risers at Stairs
Chilled Water Lines
NF 10% C 3 40 LF CAT I
* = The facility owner has the option of point-counting by polarized light microscopy (PLM) those RACM whose asbestos content is less than 10% in order to more accurately determine the asbestos content therein.
PC = Results based on Point-Count analysis
FRIABILITY F = Friable Material NF = Non-Friable Material
ACM CATEGORY RACM = Regulated ACM CAT I = Category I non-friable ACM CAT II = Category II non-friable ACM
ABBREVIATIONS: NA = Not Applicable ND = None Detected NIS = Not in Scope C = Chrysotile A = Amosite
HA = Homogeneous Area SF = Square Feet LF = Linear Feet CF = Cubic Feet
TABLE 2.2-2: SUMMARY OF HOMOGENEOUS SAMPLING AREAS
BUILDING 12 – CLC
2ND
FLOOR WALKWAY, TUNNEL, NORTHWEST 2ND
FLOOR, AND WEST ENTRANCE
MALCOM RANDALL VA MEDICAL CENTER – GAINESVILLE, FLORIDA
HA # HOMOGENEOUS MATERIAL
DESCRIPTION
HOMOGENEOUS MATERIAL
LOCATION
FRIABILITY
(F /NF)
% ASBESTOS* # OF SAMPLES
COLLECTED
APPROXIMATE
QUANTITY
ACM
CATEGORY
TSI-09 White Mastic on Fiberglass CLC Tunnel – Chilled Water
Runs
NF 10% C 3 260 LF CAT I
TSI-10 White Mastic on Fiberglass CLC Tunnel – Steam Runs NF 10% C 3 300 LF CAT I
TSI-11 White Mastic on Fiberglass CLC Tunnel – South End Branch
Lines
NF ND 3 NIS NA
TSI-12 White Mastic on Fiberglass CLC Tunnel – Under Chilled Water
& Steam Lines
NF ND 3 NIS NA
TSI-13 White Mastic on Fiberglass CLC – 1st & 2nd Floor North Set Chilled Water Lines Seams and
Elbows
NF 10% C 3 300 LF CAT I
TSI-14 White Wrap/Mastic on Fiberglass CLC – 1st & 2nd Floor South Set
Elbows
NF 10% C 3 300 LF CAT I
TSI-15 White Mudded Fitting CLC – 1st Floor West Room 101B-
12 End Fittings
F ND 3 NIS NA
VB-01 6” Blue Cove Base with Tan Mastic CLC – 2nd Floor Northwest Hall NF ND 3 NIS NA
VB-02 4” Tan Cove Base with Brown Mastic CLC – 2nd Floor Northwest Rooms NF ND 3 NIS NA
VB-03 4” Brown Cove Base with Tan Mastic CLC – 1st Floor Corridor NF ND 3 NIS NA
VB-04 6” Tan Cove Base with Tan Mastic CLC – 1st Floor West Rooms 101A-
12 and 101-12
* = The facility owner has the option of point-counting by polarized light microscopy (PLM) those RACM whose asbestos content is less than 10% in order to more accurately determine the asbestos content therein.
PC = Results based on Point-Count analysis
FRIABILITY F = Friable Material NF = Non-Friable Material
ACM CATEGORY RACM = Regulated ACM CAT I = Category I non-friable ACM CAT II = Category II non-friable ACM
ABBREVIATIONS: NA = Not Applicable ND = None Detected NIS = Not in Scope C = Chrysotile A = Amosite
TABLE 2.2-3: SUMMARY OF HOMOGENEOUS SAMPLING AREAS
TRAILER – T1
MALCOM RANDALL VA MEDICAL CENTER – GAINESVILLE, FLORIDA
HA # HOMOGENEOUS MATERIAL
DESCRIPTION
HOMOGENEOUS MATERIAL
LOCATION
FRIABILITY
(F /NF)
% ASBESTOS* # OF SAMPLES
COLLECTED
APPROXIMATE
QUANTITY
ACM
CATEGORY
CT-03 2’x2’ White Fissured Ceiling Tile T1 Trailer F ND 3 NIS NA
DW-02 Drywall Panels with Wallpaper T1 Trailer NF ND 3 NIS NA
FT-05
12”x12” White Floor Tile with Tan
Mastic and Yellow Float T1 Trailer – Corridor, Rooms 117, 113, 108, 107, 104
NF ND 3 NIS NA
FT-06
12”x12” Gray Floor Tile with
Black/Tan Mastic and Gray Float T1 Trailer – Rooms 101-103, 106, 109-112, 114-123
NF ND 3 NIS NA
M-06 Tan Caulk T1 Trailer – Windows NF ND 3 NIS NA
VB-05 4” Tan Cove Base with Tan Mastic T1 Trailer – Corridor, Rooms 117, 113, 108, 107, 104
NF ND 3 NIS NA
VB-06 6” Gray Cove Base with White Mastic T1 Trailer – Rooms 101-103, 106, 109-112, 114-123
* = The facility owner has the option of point-counting by polarized light microscopy (PLM) those RACM whose asbestos content is less than 10% in order to more accurately determine the asbestos content therein.
PC = Results based on Point-Count analysis
FRIABILITY F = Friable Material NF = Non-Friable Material
ACM CATEGORY RACM = Regulated ACM CAT I = Category I non-friable ACM CAT II = Category II non-friable ACM
ABBREVIATIONS: NA = Not Applicable ND = None Detected NIS = Not in Scope C = Chrysotile A = Amosite
TABLE 2.2-4: SUMMARY OF HOMOGENEOUS SAMPLING AREAS
TRAILER – T1A
MALCOM RANDALL VA MEDICAL CENTER – GAINESVILLE, FLORIDA
HA # HOMOGENEOUS MATERIAL
DESCRIPTION
HOMOGENEOUS MATERIAL
LOCATION
FRIABILITY
(F /NF)
% ASBESTOS* # OF SAMPLES
COLLECTED
APPROXIMATE
QUANTITY
ACM
CATEGORY
CT-04 2’x2’ White Fissured Ceiling Tile T1A Trailer F ND 3 NIS NA
DW-03 Drywall Panels with Wallpaper T1A Trailer NF ND 3 NIS NA
FT-07
12”x12” White Floor Tile with Tan
Mastic and Gray Float T1A Trailer – Excluding Rooms
100-103, 107, 110, & 111
NF ND 3 NIS NA
M-07 Tan Caulk T1A Trailer – Windows NF ND 3 NIS NA
VB-07 4” Tan Cove Base with Tan Mastic T1A Trailer – Excluding Rooms
100-103, 107, 110, & 111
* = The facility owner has the option of point-counting by polarized light microscopy (PLM) those RACM whose asbestos content is less than 10% in order to more accurately determine the asbestos content therein.
PC = Results based on Point-Count analysis
FRIABILITY F = Friable Material NF = Non-Friable Material
ACM CATEGORY RACM = Regulated ACM CAT I = Category I non-friable ACM CAT II = Category II non-friable ACM
ABBREVIATIONS: NA = Not Applicable ND = None Detected NIS = Not in Scope C = Chrysotile A = Amosite
TABLE 2.2-5: SUMMARY OF HOMOGENEOUS SAMPLING AREAS
TRAILER – T3
MALCOM RANDALL VA MEDICAL CENTER – GAINESVILLE, FLORIDA
HA # HOMOGENEOUS MATERIAL
DESCRIPTION
HOMOGENEOUS MATERIAL
LOCATION
FRIABILITY
(F /NF)
% ASBESTOS* # OF SAMPLES
COLLECTED
APPROXIMATE
QUANTITY
ACM
CATEGORY
CT-05 2’x2’ White Fissured Ceiling Tile T3 Trailer F ND 3 NIS NA
DW-04 Drywall Panels with Wallpaper T3 Trailer NF ND 3 NIS NA
FT-08
12”x12” White Floor Tile with Tan
Mastic T3 Trailer NF ND 3 NIS NA
M-08 Tan Caulk T3 Trailer NF ND 3 NIS NA
VB-08 4” Tan Cove Base with Tan Mastic T3 Trailer NF ND 3 NIS NA
* = The facility owner has the option of point-counting by polarized light microscopy (PLM) those RACM whose asbestos content is less than 10% in order to more accurately determine the asbestos content therein.
PC = Results based on Point-Count analysis
FRIABILITY F = Friable Material NF = Non-Friable Material
ACM CATEGORY RACM = Regulated ACM CAT I = Category I non-friable ACM CAT II = Category II non-friable ACM
ABBREVIATIONS: NA = Not Applicable ND = None Detected NIS = Not in Scope C = Chrysotile A = Amosite
TABLE 2.2-6: SUMMARY OF HOMOGENEOUS SAMPLING AREAS
TRAILER – T7
MALCOM RANDALL VA MEDICAL CENTER – GAINESVILLE, FLORIDA
HA # HOMOGENEOUS MATERIAL
DESCRIPTION
HOMOGENEOUS MATERIAL
LOCATION
FRIABILITY
(F /NF)
% ASBESTOS* # OF SAMPLES
COLLECTED
APPROXIMATE
QUANTITY
ACM
CATEGORY
CT-06 2’x2’ White Fissured Ceiling Tile T7 Trailer F ND 3 NIS NA
DW-05 Drywall Panels with Wallpaper T7 Trailer NF ND 3 NIS NA
FT-09
12”x12” White Floor Tile with Tan
Mastic and Gray Float T7 Trailer NF ND 3 NIS NA
M-09 Tan Caulk T7 Trailers – Windows NF ND 3 NIS NA
VB-09 4” Tan Cove Base with Tan Mastic T7 Trailer NF ND 3 NIS NA
* = The facility owner has the option of point-counting by polarized light microscopy (PLM) those RACM whose asbestos content is less than 10% in order to more accurately determine the asbestos content therein.
PC = Results based on Point-Count analysis
FRIABILITY F = Friable Material NF = Non-Friable Material
ACM CATEGORY RACM = Regulated ACM CAT I = Category I non-friable ACM CAT II = Category II non-friable ACM
ABBREVIATIONS: NA = Not Applicable ND = None Detected NIS = Not in Scope C = Chrysotile A = Amosite
TABLE 2.2-7: SUMMARY OF HOMOGENEOUS SAMPLING AREAS
TRAILER – T8 & SHED
MALCOM RANDALL VA MEDICAL CENTER – GAINESVILLE, FLORIDA
HA # HOMOGENEOUS MATERIAL
DESCRIPTION
HOMOGENEOUS MATERIAL
LOCATION
FRIABILITY
(F /NF)
% ASBESTOS* # OF SAMPLES
COLLECTED
APPROXIMATE
QUANTITY
ACM
CATEGORY
CT-07 2’x4’ White Fissured Ceiling Tile T8 Trailer F ND 3 NIS NA
DW-06 Drywall Panels with Wallpaper T8 Trailer NF ND 3 NIS NA
FT-10
12”x12” White Floor Tile with Tan
Mastic T8 Trailer NF ND 3 NIS NA
M-10 Tan Caulk T8 Trailers NF ND 3 NIS NA
M-11 White Caulk T8 Trailer – Room 101 Door NF ND 3 NIS NA
M-12 Gray Caulk Shed – Under Door NF ND 3 NIS NA
VB-10 4” Tan Cove Base with Tan Mastic T8 Trailer NF ND 3 NIS NA
* = The facility owner has the option of point-counting by polarized light microscopy (PLM) those RACM whose asbestos content is less than 10% in order to more accurately determine the asbestos content therein.
PC = Results based on Point-Count analysis
FRIABILITY F = Friable Material NF = Non-Friable Material
ACM CATEGORY RACM = Regulated ACM CAT I = Category I non-friable ACM CAT II = Category II non-friable ACM
ABBREVIATIONS: NA = Not Applicable ND = None Detected NIS = Not in Scope C = Chrysotile A = Amosite
TABLE 2.2-8: SUMMARY OF HOMOGENEOUS SAMPLING AREAS
TRAILER – T9
MALCOM RANDALL VA MEDICAL CENTER – GAINESVILLE, FLORIDA
HA # HOMOGENEOUS MATERIAL
DESCRIPTION
HOMOGENEOUS MATERIAL
LOCATION
FRIABILITY
(F /NF)
% ASBESTOS* # OF SAMPLES
COLLECTED
APPROXIMATE
QUANTITY
ACM
CATEGORY
CT-08 2’x2’ White Fissured Ceiling Tile T9 Trailer F ND 3 NIS NA
DW-07 Drywall Panels with Wallpaper T9 Trailer NF ND 3 NIS NA
FT-11
12”x12” White Floor Tile with Tan
Mastic T9 Trailer NF ND 3 NIS NA
M-13 White Sink Insulation T9 Trailer – Room 110 NF ND 3 NIS NA
VB-11 4” Tan Cove Base with Tan Mastic T9 Trailer NF ND 3 NIS NA
* = The facility owner has the option of point-counting by polarized light microscopy (PLM) those RACM whose asbestos content is less than 10% in order to more accurately determine the asbestos content therein.
PC = Results based on Point-Count analysis
FRIABILITY F = Friable Material NF = Non-Friable Material
ACM CATEGORY RACM = Regulated ACM CAT I = Category I non-friable ACM CAT II = Category II non-friable ACM
ABBREVIATIONS: NA = Not Applicable ND = None Detected NIS = Not in Scope C = Chrysotile A = Amosite
TABLE 2.2-9: SUMMARY OF HOMOGENEOUS SAMPLING AREAS
TRAILER – T10
MALCOM RANDALL VA MEDICAL CENTER – GAINESVILLE, FLORIDA
HA # HOMOGENEOUS MATERIAL
DESCRIPTION
HOMOGENEOUS MATERIAL
LOCATION
FRIABILITY
(F /NF)
% ASBESTOS* # OF SAMPLES
COLLECTED
APPROXIMATE
QUANTITY
ACM
CATEGORY
CT-09
2’x2’ White Fissured Recessed Ceiling
Tile T10 Trailer F ND 3 NIS NA
DW-08 Drywall Panels with Wallpaper T10 Trailer NF ND 3 NIS NA
FT-12
12”x12” White with Red Specks Floor
Tile with Tan Mastic T10 Trailer NF ND 3 NIS NA
FT-13
12”x12” White with Gray Floor Tile with Tan Mastic T10 Trailer – Room 1103 Southeast
Closet
NF ND 3 NIS NA
M-14 White Sink Insulation T10 Trailer – Room 110 NF ND 3 NIS NA
VB-12 4” Tan Cove Base with Tan Mastic T10 Trailer NF ND 3 NIS NA
3.0 CONCLUSIONS AND RECOMMENDATIONS
3.1 GENERAL
Asbestos-containing materials (ACMs) were identified in the scope of this survey. General and specific conclusions and recommendations are provided below.
The EPA, OSHA and the State of Florida have promulgated regulations dealing with asbestos.
For commercial building owners, the EPA NESHAP (40 CFR 61) regulations require removal of RACM, prior to conducting activities which might disturb the material. They also deal with notification, handling and disposal of asbestos.
The EPA recommends that an Operations and Maintenance (O&M) Program be developed for any facilities with ACM, and this Program should address all ACM (known and/or assumed) present. The O&M Program establishes notification and training requirements along with special procedures for working around the ACM. The O&M Program would remain in effect until all asbestos is removed.
Category I and Category II non-friable materials, as defined by the EPA, may remain within a facility during demolition with no potential cessation of work, provided they remain non-friable and the appropriate engineering controls (i.e., wet methods) are utilized, with the resulting waste disposed of as asbestos-containing waste. However, there is no guarantee that these materials will remain non-friable. If the materials become friable, then they are classified as RACM.
RACM, as defined by the EPA, must be removed prior to renovation or demolition activities that may disturb the materials.
The OSHA regulations deal with employee exposure to airborne asbestos fibers. The regulations restrict employee exposure, and require special monitoring, training and handling procedures when dealing with asbestos. Additionally, OSHA has regulations that may supersede the EPA regulations. In order to protect the worker, OSHA has established a permissible exposure limit (PEL), which limits employee exposure to airborne fiber concentrations. OSHA requires objective evidence that the PEL will not be exceeded, as justification that personal air monitoring and engineering controls will not be required. OSHA has also established rules requiring the containerization and labeling of asbestos waste.
The State regulations require that anyone involved in asbestos consulting activities be a licensed asbestos consultant and that anyone involved in asbestos abatement, with the exception of roofing materials, be a licensed asbestos abatement contractor.
3.2 SPECIFIC
CLC – Building 12 2nd Floor Walkway, Tunnel, Northwest 2nd Floor, and West Entrance
FT-01: Black Mastic associated with 12”x12” Beige Speckled Floor Tile FT-02: 12”x12” Dark Tan Floor Tile with Black Mastic FT-03: 12”x12” Light Tan Streaked Floor Tile with Black Mastic MAS-02: White Duct Mastic TSI-08: White Mastic on Fiberglass TSI-09: White Mastic on Fiberglass TSI-10: White Mastic on Fiberglass TSI-13: White Mastic on Fiberglass TSI-14: White Wrap/Mastic on Fiberglass
These materials are defined by the EPA as a Category I non-friable materials. These materials do not appear to present a significant issue, as observed, at the time of the survey. We recommend that the identified ACM be maintained as part of an O&M Program and periodically monitored for any changes in condition. Additionally, we recommend that a licensed asbestos abatement contractor properly remove and dispose of the ACM prior to conducting renovation activities that might disturb the ACM. However, Florida regulations do allow a properly trained and licensed roofing contractor to disturb asphalt roofing materials.
Assumed Materials
Suspect Locker Door Insulation observed within the facility appeared to be in generally good condition and does not present a significant issue, as observed, at the time of the survey. We recommend that these materials be maintained as part of an O&M Program and periodically monitored for any changes in condition. Additionally, should planned renovation and/or demolition activities involve the disturbance of these materials, we recommend that they be sampled and analyzed for asbestos content, and if determined to be ACM, be properly removed and disposed by a licensed asbestos abatement contractor prior to conducting such activities.
Additionally, due to accessibility issues, the following areas were not accessed at the time of the survey:
1. Room 130B-12 of the CLC;
2. Rooms 104 and 106 of Trailer T1;
3. AFGE Union areas of Trailer T3;
4. Rooms 112 and 113 of Trailer T7;
5. Offices on the west of Trailer T10;
6. Conference Room and south closet of Trailer T10;
7. Interior of police storage shed.
Should planned renovation and/or demolition activities involve the disturbance of building materials in these areas, we recommend that they be sampled and analyzed for asbestos content, and if determined to be ACM, be properly removed and disposed by a licensed asbestos abatement contractor prior to conducting such activities.
4.0 LIMITATIONS AND CONDITIONS
As a result of previous renovations, there may be hidden materials, such as floor tile, sheet vinyl flooring, insulation, etc. These materials may be found in various areas hidden under existing flooring materials or in wall cavities. Any materials found during construction activities, either not addressed in this survey report, or similar to the ACM identified in this survey report should be assumed to be ACM until sampling and analysis documents otherwise.
Because of the hidden nature of many building components (i.e. within mechanical chases), it may be impossible to determine if all of the suspect building materials have been located and subsequently tested. Destructive testing in some instances is not a viable option. We cannot, therefore, guarantee that all potential ACM has been located. For the same reasons, estimates of quantities and/or conditions are subject to readily apparent situations, and our findings reflect this condition. We do warrant, however, that the investigations and methodology reflect our best efforts based upon the prevailing standard of care in the environmental industry.
The information contained in this report was prepared based upon specific parameters and regulations in force at the time of this report. The information herein is only for the specific use of the client and GLE. GLE accepts no responsibility for the use, interpretation, or reliance by other parties on the information contained herein, unless prior written authorization has been obtained from GLE.
APPENDIX A
Analytical Results and Chain of Custody
SUMMARY OF BULK SAMPLE ANALYSIS
Malcolm Randall VAMC; Trailer T9 18950-00483
Sample Sample Type Fiber Type
CT-08A 2x2 White Fissured
Ceiling Tile 70% Mineral Wool
30% Perlite, Quartz, Calcite
CT-08B 2x2 White Fissured
Ceiling Tile 70% Mineral Wool
30% Perlite, Quartz, Calcite
CT-08C-QC 2x2 White Fissured
Ceiling Tile 70% Mineral Wool
30% Perlite, Quartz, Calcite
DW-01A Drywall Panels &
Wallpaper 100% Gypsum, Quartz, Calcite, Clay
DW-01B Drywall Panels &
Wallpaper 100% Gypsum, Quartz, Calcite, Clay
DW-01C Drywall Panels &
Wallpaper 100% Gypsum, Quartz, Calcite, Clay
FT-11A 12x12 White Floor Tile &
Tan Mastic 100% Polymer, Quartz, Calcite, Clay, Mica
FT-11B 12x12 White Floor Tile &
Tan Mastic 100% Polymer, Quartz, Calcite, Clay, Mica
FT-11C 12x12 White Floor Tile &
Tan Mastic 100% Polymer, Quartz, Calcite, Clay, Mica
M-13A White Sink Undercoat 100% Polymer, Quartz, Calcite, Clay, Mica
M-13B White Sink Undercoat 100% Polymer, Quartz, Calcite, Clay, Mica
M-13C White Sink Undercoat 100% Polymer, Quartz, Calcite, Clay, Mica
Darryl Neldner
* Polarized Light Microscopy coupled with dispersion is the technique used for identification in accordance with EPA 600/M4-82-020, EPA 600/R-93/116, and NIOSH Method 9002.
** The percentage of each component is visually estimated. The result of this analysis relate only to the material tested.
The report shall not be used to claim product endorsement by NVLAP or any agency of the U.S. Government.
(>1% greater than one percent, <1% less than one percent) QC - Sample reanalyzed for QA/QC.
Analysis performed by GLE Associates, Inc. NVLAP Code 102003-0, CO AL-17485, TX 30-0337
*** This report shall not be reproduced except in full, without the written approval of the laboratory. GLE Report # 22632
Analyst / Approved
Signatory:
Feedback regarding laboratory performance should be addressed to lab@gleassociates.com.
Report Date: 5/18/2018
Malcolm Randall VAMC; Trailer T9 18950-00483
Sample Sample Type Fiber Type
VB-11A-QC 4" Tan Cove Base & Tan
Mastic 100% Polymer
VB-11B 4" Tan Cove Base & Tan
Mastic 100% Polymer
VB-11C 4" Tan Cove Base & Tan
Mastic 100% Polymer
Darryl Neldner
* Polarized Light Microscopy coupled with dispersion is the technique used for identification in accordance with EPA 600/M4-82-020, EPA 600/R-93/116, and NIOSH Method 9002.
** The percentage of each component is visually estimated. The result of this analysis relate only to the material tested.
The report shall not be used to claim product endorsement by NVLAP or any agency of the U.S. Government.
(>1% greater than one percent, <1% less than one percent) QC - Sample reanalyzed for QA/QC.
Analysis performed by GLE Associates, Inc. NVLAP Code 102003-0, CO AL-17485, TX 30-0337
*** This report shall not be reproduced except in full, without the written approval of the laboratory. GLE Report # 22632
Analyst / Approved
Signatory:
Alliance; Trailer T1A 18950-00483
Sample Sample Type Fiber Type
CT-04A 2x2 White Fissured
Ceiling Tile 70% Mineral Wool
30% Perlite, Quartz, Calcite
CT-04B 2x2 White Fissured
Ceiling Tile 70% Mineral Wool
30% Perlite, Quartz, Calcite
CT-04C-QC 2x2 White Fissured
Ceiling Tile 70% Mineral Wool
30% Perlite, Quartz, Calcite
DW-03A Drywall & Joint
Compound/Wallpaper 100% Gypsum, Quartz, Calcite, Clay
DW-03B Drywall & Joint
Compound/Wallpaper 100% Gypsum, Quartz, Calcite, Clay
DW-03C Drywall & Joint
Compound/Wallpaper 100% Gypsum, Quartz, Calcite, Clay
FT-07A 12x12 White Floor Tile &
Tan Mastic/Gray Float 100% Polymer, Quartz, Calcite, Clay, Mica
FT-07B 12x12 White Floor Tile &
Tan Mastic/Gray Float 100% Polymer, Quartz, Calcite, Clay, Mica
FT-07C 12x12 White Floor Tile &
Tan Mastic/Gray Float 100% Polymer, Quartz, Calcite, Clay, Mica
M-07A Tan Caulk 100% Polymer, Quartz, Calcite, Clay, Mica
M-07B Tan Caulk 100% Polymer, Quartz, Calcite, Clay, Mica
M-07C Tan Caulk 100% Polymer, Quartz, Calcite, Clay, Mica
Darryl Neldner
* Polarized Light Microscopy coupled with dispersion is the technique used for identification in accordance with EPA 600/M4-82-020, EPA 600/R-93/116, and NIOSH Method 9002.
** The percentage of each component is visually estimated. The result of this analysis relate only to the material tested.
The report shall not be used to claim product endorsement by NVLAP or any agency of the U.S. Government.
(>1% greater than one percent, <1% less than one percent) QC - Sample reanalyzed for QA/QC.
Analysis performed by GLE Associates, Inc. NVLAP Code 102003-0, CO AL-17485, TX 30-0337
*** This report shall not be reproduced except in full, without the written approval of the laboratory. GLE Report # 22633
Analyst / Approved
Signatory:
Alliance; Trailer T1A 18950-00483
Sample Sample Type Fiber Type
VB-07A-QC 4" Tan Cove Base & Tan
Mastic 100% Polymer
VB-07B 4" Tan Cove Base & Tan
Mastic 100% Polymer
VB-07C 4" Tan Cove Base & Tan
Mastic 100% Polymer
Darryl Neldner
* Polarized Light Microscopy coupled with dispersion is the technique used for identification in accordance with EPA 600/M4-82-020, EPA 600/R-93/116, and NIOSH Method 9002.
** The percentage of each component is visually estimated. The result of this analysis relate only to the material tested.
The report shall not be used to claim product endorsement by NVLAP or any agency of the U.S. Government.
(>1% greater than one percent, <1% less than one percent) QC - Sample reanalyzed for QA/QC.
Analysis performed by GLE Associates, Inc. NVLAP Code 102003-0, CO AL-17485, TX 30-0337
*** This report shall not be reproduced except in full, without the written approval of the laboratory. GLE Report # 22633
Analyst / Approved
Signatory:
Malcom Randall VAMC; Trailer T3 18950-00483
Sample Sample Type Fiber Type
CT-05A 2x2 White Fissured
Ceiling Tile 70% Mineral Wool
30% Perlite, Quartz, Calcite
CT-05B 2x2 White Fissured
Ceiling Tile 70% Mineral Wool
30% Perlite, Quartz, Calcite
CT-05C-QC 2x2 White Fissured
Ceiling Tile 70% Mineral Wool
30% Perlite, Quartz, Calcite
DW-04A Drywall Panels &
Wallpaper 100% Gypsum, Quartz, Calcite, Clay
DW-04B Drywall Panels &
Wallpaper 100% Gypsum, Quartz, Calcite, Clay
DW-04C Drywall Panels &
Wallpaper 100% Gypsum, Quartz, Calcite, Clay
FT-08A 12x12 White Floor Tile &
Tan Mastic 100% Polymer, Quartz, Calcite, Clay, Mica
FT-08B 12x12 White Floor Tile &
Tan Mastic 100% Polymer, Quartz, Calcite, Clay, Mica
FT-08C 12x12 White Floor Tile &
Tan Mastic 100% Polymer, Quartz, Calcite, Clay, Mica
M-08A Tan Caulk 100% Polymer, Quartz, Calcite, Clay, Mica
M-08B Tan Caulk 100% Polymer, Quartz, Calcite, Clay, Mica
M-08C Tan Caulk 100% Polymer, Quartz, Calcite, Clay, Mica
Darryl Neldner
* Polarized Light Microscopy coupled with dispersion is the technique used for identification in accordance with EPA 600/M4-82-020, EPA 600/R-93/116, and NIOSH Method 9002.
** The percentage of each component is visually estimated. The result of this analysis relate only to the material tested.
The report shall not be used to claim product endorsement by NVLAP or any agency of the U.S. Government.
(>1% greater than one percent, <1% less than one percent) QC - Sample reanalyzed for QA/QC.
Analysis performed by GLE Associates, Inc. NVLAP Code 102003-0, CO AL-17485, TX 30-0337
*** This report shall not be reproduced except in full, without the written approval of the laboratory. GLE Report # 22634
Analyst / Approved
Signatory:
Malcom Randall VAMC; Trailer T3 18950-00483
Sample Sample Type Fiber Type
VB-08A-QC 4" Tan Cove Base & Tan
Mastic 100% Polymer
VB-08B 4" Tan Cove Base & Tan
Mastic 100% Polymer
VB-08C 4" Tan Cove Base & Tan
Mastic 100% Polymer
Darryl Neldner
* Polarized Light Microscopy coupled with dispersion is the technique used for identification in accordance with EPA 600/M4-82-020, EPA 600/R-93/116, and NIOSH Method 9002.
** The percentage of each component is visually estimated. The result of this analysis relate only to the material tested.
The report shall not be used to claim product endorsement by NVLAP or any agency of the U.S. Government.
(>1% greater than one percent, <1% less than one percent) QC - Sample reanalyzed for QA/QC.
Analysis performed by GLE Associates, Inc. NVLAP Code 102003-0, CO AL-17485, TX 30-0337
*** This report shall not be reproduced except in full, without the written approval of the laboratory. GLE Report # 22634
Analyst / Approved
Signatory:
Malcolm Randall VAMC; Trailer T7 18950-00483
Sample Sample Type Fiber Type
CT-06A 2x2 White Fissured
Ceiling Tile 70% Mineral Wool
30% Perlite, Quartz, Calcite
CT-06B 2x2 White Fissured
Ceiling Tile 70% Mineral Wool
30% Perlite, Quartz, Calcite
CT-06C-QC 2x2 White Fissured
Ceiling Tile 70% Mineral Wool
30% Perlite, Quartz, Calcite
DW-05A Drywall Panels &
Wallpaper 100% Gypsum, Quartz, Calcite, Clay
DW-05B Drywall Panels &
Wallpaper 100% Gypsum, Quartz, Calcite, Clay
DW-05C Drywall Panels &
Wallpaper 100% Gypsum, Quartz, Calcite, Clay
FT-09A 12x12 White Floor Tile &
Tan Mastic/Gray Float 100% Polymer, Quartz, Calcite, Clay, Mica
FT-09B 12x12 White Floor Tile &
Tan Mastic/Gray Float 100% Polymer, Quartz, Calcite, Clay, Mica
FT-09C 12x12 White Floor Tile &
Tan Mastic/Gray Float 100% Polymer, Quartz, Calcite, Clay, Mica
M-09A Tan Caulk 100% Polymer, Quartz, Calcite, Clay, Mica
M-09B Tan Caulk 100% Polymer, Quartz, Calcite, Clay, Mica
M-09C Tan Caulk 100% Polymer, Quartz, Calcite, Clay, Mica
Darryl Neldner
* Polarized Light Microscopy coupled with dispersion is the technique used for identification in accordance with EPA 600/M4-82-020, EPA 600/R-93/116, and NIOSH Method 9002.
** The percentage of each component is visually estimated. The result of this analysis relate only to the material tested.
The report shall not be used to claim product endorsement by NVLAP or any agency of the U.S. Government.
(>1% greater than one percent, <1% less than one percent) QC - Sample reanalyzed for QA/QC.
Analysis performed by GLE Associates, Inc. NVLAP Code 102003-0, CO AL-17485, TX 30-0337
*** This report shall not be reproduced except in full, without the written approval of the laboratory. GLE Report # 22635
Analyst / Approved
Signatory:
Malcolm Randall VAMC; Trailer T7 18950-00483
Sample Sample Type Fiber Type
VB-09A-QC 4" Tan Cove Base & Tan
Mastic 100% Polymer
VB-09B 4" Tan Cove Base & Tan
Mastic 100% Polymer
VB-09C 4" Tan Cove Base & Tan
Mastic 100% Polymer
Darryl Neldner
* Polarized Light Microscopy coupled with dispersion is the technique used for identification in accordance with EPA 600/M4-82-020, EPA 600/R-93/116, and NIOSH Method 9002.
** The percentage of each component is visually estimated. The result of this analysis relate only to the material tested.
The report shall not be used to claim product endorsement by NVLAP or any agency of the U.S. Government.
(>1% greater than one percent, <1% less than one percent) QC - Sample reanalyzed for QA/QC.
Analysis performed by GLE Associates, Inc. NVLAP Code 102003-0, CO AL-17485, TX 30-0337
*** This report shall not be reproduced except in full, without the written approval of the laboratory. GLE Report # 22635
Analyst / Approved
Signatory:
Malcom Randall VAMC; Trailer T1Q 18950-00483
Sample Sample Type Fiber Type
CT-09A 2x2 White Fissured
Ceiling Tile 70% Mineral Wool
30% Perlite, Quartz, Calcite
CT-09B 2x2 White Fissured
Ceiling Tile 70% Mineral Wool
30% Perlite, Quartz, Calcite
CT-09C-QC 2x2 White Fissured
Ceiling Tile 70% Mineral Wool
30% Perlite, Quartz, Calcite
DW-08A Drywall Panels &
Wallpaper 100% Gypsum, Quartz, Calcite, Clay
DW-08B Drywall Panels &
Wallpaper 100% Gypsum, Quartz, Calcite, Clay
DW-08C Drywall Panels &
Wallpaper 100% Gypsum, Quartz, Calcite, Clay
FT-12A 12x12 White/Red Floor
Tile & Tan Mastic 100% Polymer, Quartz, Calcite, Clay, Mica
FT-12B 12x12 White/Red Floor
Tile & Tan Mastic 100% Polymer, Quartz, Calcite, Clay, Mica
FT-12C 12x12 White/Red Floor
Tile & Tan Mastic 100% Polymer, Quartz, Calcite, Clay, Mica
FT-13A 12x12 White/Gray Floor
Tile & Tan Mastic 100% Polymer, Quartz, Calcite, Clay, Mica
FT-13B 12x12 White/Gray Floor
Tile & Tan Mastic 100% Polymer, Quartz, Calcite, Clay, Mica
Darryl Neldner
* Polarized Light Microscopy coupled with dispersion is the technique used for identification in accordance with EPA 600/M4-82-020, EPA 600/R-93/116, and NIOSH Method 9002.
** The percentage of each component is visually estimated. The result of this analysis relate only to the material tested.
The report shall not be used to claim product endorsement by NVLAP or any agency of the U.S. Government.
(>1% greater than one percent, <1% less than one percent) QC - Sample reanalyzed for QA/QC.
Analysis performed by GLE Associates, Inc. NVLAP Code 102003-0, CO AL-17485, TX 30-0337
*** This report shall not be reproduced except in full, without the written approval of the laboratory. GLE Report # 22636
Analyst / Approved
Signatory:
Report Date: 5/21/2018
Malcom Randall VAMC; Trailer T1Q 18950-00483
Sample Sample Type Fiber Type
FT-13C 12x12 White/Gray Floor
Tile & Tan Mastic 100% Polymer, Quartz, Calcite, Clay, Mica
M-14A-QC White Sink Undercoat 100% Polymer, Quartz, Calcite, Clay, Mica
M-14B White Sink Undercoat 100% Polymer, Quartz, Calcite, Clay, Mica
M-14C White Sink Undercoat 100% Polymer, Quartz, Calcite, Clay, Mica
VB-12A 4" Tan Cove Base & Tan
Mastic 100% Polymer
VB-12B 4" Tan Cove Base & Tan
Mastic 100% Polymer
VB-12C 4" Tan Cove Base & Tan
Mastic 100% Polymer
Darryl Neldner
* Polarized Light Microscopy coupled with dispersion is the technique used for identification in accordance with EPA 600/M4-82-020, EPA 600/R-93/116, and NIOSH Method 9002.
** The percentage of each component is visually estimated. The result of this analysis relate only to the material tested.
The report shall not be used to claim product endorsement by NVLAP or any agency of the U.S. Government.
(>1% greater than one percent, <1% less than one percent) QC - Sample reanalyzed for QA/QC.
Analysis performed by GLE Associates, Inc. NVLAP Code 102003-0, CO AL-17485, TX 30-0337
*** This report shall not be reproduced except in full, without the written approval of the laboratory. GLE Report # 22636
Analyst / Approved
Signatory:
Malcolm Randall VAMC; Trailer T8 18950-00483
Sample Sample Type Fiber Type
CT-07A 2x4 White Fissured
Ceiling Tile 70% Mineral Wool
30% Perlite, Quartz, Calcite
CT-07B 2x4 White Fissured
Ceiling Tile 70% Mineral Wool
30% Perlite, Quartz, Calcite
CT-07C-QC 2x4 White Fissured
Ceiling Tile 70% Mineral Wool
30% Perlite, Quartz, Calcite
DW-06A Drywall Panels &
Wallpaper 100% Gypsum, Quartz, Calcite, Clay
DW-06B Drywall Panels &
Wallpaper 100% Gypsum, Quartz, Calcite, Clay
DW-06C Drywall Panels &
Wallpaper 100% Gypsum, Quartz, Calcite, Clay
FT-10A 12x12 White Floor Tile &
Tan Mastic 100% Polymer, Quartz, Calcite, Clay, Mica
FT-10B 12x12 White Floor Tile &
Tan Mastic 100% Polymer, Quartz, Calcite, Clay, Mica
FT-10C 12x12 White Floor Tile &
Tan Mastic 100% Polymer, Quartz, Calcite, Clay, Mica
M-10A Tan Caulk 100% Polymer, Quartz, Calcite, Clay, Mica
M-10B Tan Caulk 100% Polymer, Quartz, Calcite, Clay, Mica
M-10C Tan Caulk 100% Polymer, Quartz, Calcite, Clay, Mica
Darryl Neldner
* Polarized Light Microscopy coupled with dispersion is the technique used for identification in accordance with EPA 600/M4-82-020, EPA 600/R-93/116, and NIOSH Method 9002.
** The percentage of each component is visually estimated. The result of this analysis relate only to the material tested.
The report shall not be used to claim product endorsement by NVLAP or any agency of the U.S. Government.
(>1% greater than one percent, <1% less than one percent) QC - Sample reanalyzed for QA/QC.
Analysis performed by GLE Associates, Inc. NVLAP Code 102003-0, CO AL-17485, TX 30-0337
*** This report shall not be reproduced except in full, without the written approval of the laboratory. GLE Report # 22637
Analyst / Approved
Signatory:
Malcolm Randall VAMC; Trailer T8 18950-00483
Sample Sample Type Fiber Type
M-11A-QC White Caulk 100% Polymer, Quartz, Calcite, Clay, Mica
M-11B White Caulk 100% Polymer, Quartz, Calcite, Clay, Mica
M-11C White Caulk 100% Polymer, Quartz, Calcite, Clay, Mica
M-12A Gray Caulk 100% Polymer, Quartz, Calcite, Clay, Mica
M-12B Gray Caulk 100% Polymer, Quartz, Calcite, Clay, Mica
M-12C Gray Caulk 100% Polymer, Quartz, Calcite, Clay, Mica
VB-10A 4" Tan Cove Base & Tan
Mastic 100% Polymer
VB-10B 4" Tan Cove Base & Tan
Mastic 100% Polymer
VB-10C 4" Tan Cove Base & Tan
Mastic 100% Polymer
Darryl Neldner
* Polarized Light Microscopy coupled with dispersion is the technique used for identification in accordance with EPA 600/M4-82-020, EPA 600/R-93/116, and NIOSH Method 9002.
** The percentage of each component is visually estimated. The result of this analysis relate only to the material tested.
The report shall not be used to claim product endorsement by NVLAP or any agency of the U.S. Government.
(>1% greater than one percent, <1% less than one percent) QC - Sample reanalyzed for QA/QC.
Analysis performed by GLE Associates, Inc. NVLAP Code 102003-0, CO AL-17485, TX 30-0337
*** This report shall not be reproduced except in full, without the written approval of the laboratory. GLE Report # 22637
Analyst / Approved
Signatory:
Malcom Randall VAMC; Trailer T1 18950-00483
Sample Sample Type Fiber Type
CT-03A 2x2 White Fissured
Ceiling Tile 70% Mineral Wool
30% Perlite, Quartz, Calcite
CT-03B 2x2 White Fissured
Ceiling Tile 70% Mineral Wool
30% Perlite, Quartz, Calcite
CT-03C-QC 2x2 White Fissured
Ceiling Tile 70% Mineral Wool
30% Perlite, Quartz, Calcite
DW-02A Drywall Panels &
Wallpaper 100% Gypsum, Quartz, Calcite, Clay
DW-02B Drywall Panels &
Wallpaper 100%…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .