This document contains the results of a limited lead-containing paint survey conducted at the Malcom Randall VA Medical Center in Gainesville, Florida. The survey identified lead-containing paint in four out of forty samples tested. It provides analytical results and recommendations for compliance with OSHA regulations for construction projects that will disturb lead-containing paint. Personal protective equipment and employee exposure monitoring are advised, as well as lead abatement by a qualified contractor for activities involving abrasive blasting or torch cutting. Waste characterization testing and adherence to EPA renovation rules are also recommended. The related federal contract opportunity involves construction of a new 26,000 square foot administration building on the medical center campus. Work includes demolition, site work, utilities, and mechanical, electrical and architectural construction.
View the file
Other files for this federal contract opportunity
Show all 32
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
2228 NW 40th Terrace, Suite C Gainesville, Florida 32605
352-335-6648 • Fax 352-335-6187
LIMITED LEAD-CONTAINING PAINT
SURVEY REPORT
Chiller Area – Section “M,” Buildings 12, T1, T1A, T3, T7, T8, T9, T10, B26, B27 & Shed Project VA248-16-R-0441
Malcom Randall VA Medical Center 1601 SW Archer Road
Gainesville, Florida 32608-1197
GLE Project No.: 18950-00483
Prepared for:
Mr. Douglas Sangster, AIA, CGC President
Alliance Design & Construction, Inc.
P.O. Box 1296
Winter Park, Florida 32790
June 2018
Prepared by:
GLE Associates, Inc.
2228 NW 40th Terrace, Suite C | Gainesville, Florida 32605 | 352-335-6648 | Fax: 352-335-6187 Tampa | Orlando | Ft. Lauderdale | Miami | Jacksonville | Atlanta | Nashville
Architecture AA 0002369 Engineer CA 5483 Asbestos ZA 0000034 Geology GB 0000297
June 20, 2018
Mr. Douglas Sangster, AIA, CGC via e-mail: dsangster@alliance-dci.com President Alliance Design & Construction, Inc.
P.O. Box 1296 Winter Park, Florida 32790
RE: Limited Lead-Containing Paint Survey Report Chiller Area – Section “M,” Buildings 12, T1, T1A, T3, T7, T8, T9, T10, B26, B27 & Shed Project VA248-16-R-0441 Malcom Randall VA Medical Center 1601 SW Archer Road Gainesville, Florida 32608-1197
Project No.: 18950-00483
Dear Mr. Sangster:
GLE Associates, Inc. (GLE) performed a limited survey to identify lead-containing paint on May 14, 2018 through May 16, 2019, at Malcom Randall VA Medical Center, located in Gainesville, Florida. The survey was performed by Mr. Cullen Schmitz and Mr. Michael D. Harrell with GLE. This report outlines the sampling and testing procedures, and presents the results along with our conclusions and recommendations.
GLE appreciates the opportunity to work with you on this project. Should you have questions regarding any of the information contained in this report, please do not hesitate to contact our office.
Sincerely, GLE Associates, Inc.
Michael D. Harrell Robert B. Greene, PE, PG, CIH, LEED AP Project Manager President
MDH/RBG/lr
G:\Work\Asbestos\'18\18950-VA\00483-Bldgs 12, T1, T1A, T3, T7, T8, T9, T10, B26, B27 & Shed\Reports\Lead\Lead Survey Report.doc
TABLE OF CONTENTS
1.0 EXECUTIVE SUMMARY 1
1.1 Introduction 1
1.2 Facility Description 1
2.0 RESULTS 6
2.1 Lead Survey Procedures 6
2.2 Identified Suspect Lead-Containing Paint 7
Table 2.2-1 — Summary of Analytical Results
3.0 CONCLUSIONS AND RECOMMENDATIONS 11
4.0 LIMITATIONS AND CONDITIONS 11
APPENDICES
Appendix A – Analytical Results and Chain of Custody Appendix B – Personnel and Laboratory Qualifications
1.0 EXECUTIVE SUMMARY
1.1 INTRODUCTION
On May 14, 2018 through May 16, 2018, a limited lead-containing paint survey was conducted within Buildings 12, T1, T1A, T3, T7, T8, T9, T10, B26, B27 and Shed, located at Malcom Randall VA Medical Center, in Gainesville, Florida. The scope of the survey was limited to the chiller area of “Section ‘M’,” the tunnel associated with the chiller area, the tunnel from the CLC (Building 12) to the main building, the second floor walkway of the CLC, the second floor northwest of the CLC associated with planned tie-ins (consisting of Rooms 212-12 through 220- 12 and associated corridors and NW balcony), the ground floor west entrance to the CLC (and adjacent Rooms 101-12, 101A-12, 130B-12, and associated corridor), and the trailers and outbuildings listed above. The scope of the survey did not include roofing materials, at the request of the property owner. At the time of the survey, Room 130B-12 of the CLC was inaccessible. Additionally, within the trailers, Rooms 104 and 106 of Trailer T1, the AFGE Union areas of Trailer T3, Rooms 112 and 113 of Trailer T7, offices on the west of Trailer T10 and the conference room of Trailer T10, and the interior of the police storage shed were inaccessible at the time of the survey. The survey was performed by Mr. Cullen Schmitz and Mr.
Michael D. Harrell, with GLE.
1.2 FACILITY DESCRIPTION
A summary of the facility investigated is outlined in the table below.
Chiller Area – Section “M”
Facility Type: Commercial Construction Date: Unknown Number of Floors: One
Exterior Floor Support: Concrete Floor Wall Support: Concrete Masonry Units Exterior Finish: Brick Roof System Type: Not in Scope
Interior Wall Substrate: Concrete Masonry Units Wall Finishes: Paint Floor Finishes: None Ceiling System: Concrete Deck Ceiling Finishes: Paint
Building 12 – CLC Facility Type: Hospital, Residential Construction Date: Unknown Number of Floors: Two In Scope
Exterior Floor Support: Concrete Floor Wall Support: Concrete Masonry Units Exterior Finish: Paint Roof System Type: Not In Scope
Interior Wall Substrate: Drywall and Joint Compound Wall Finishes: Paint, Wallpaper, Cove Base Floor Finishes: Vinyl Floor Tile, Ceramic Tile Ceiling System: Suspended Ceiling System Ceiling Finishes: Suspended Ceiling Tiles
B26 & B27
Facility Type: Storage Construction Date: Unknown Number of Floors: One
Exterior Floor Support: Grate Wall Support: Metal Framing Exterior Finish: Metal Siding Roof System Type: Not In Scope
Interior Wall Substrate: Metal Container Wall Finishes: Paint Floor Finishes: None Ceiling System: Metal Ceiling Finishes: Paint
T1
Facility Type: Administration Construction Date: Unknown Number of Floors: One
Exterior Floor Support: Raised Wood Floor Wall Support: Wood Framing Exterior Finish: Metal Siding Roof System Type: Not In Scope
Interior Wall Substrate: Drywall Wall Finishes: Wallpaper, Cove Base Floor Finishes: Vinyl Floor Tile, Carpet
T1A
Construction Date: Unknown Number of Floors: One
Exterior Floor Support: Raised Wood Floor Wall Support: Wood Framing Exterior Finish: Metal Siding Roof System Type: Not In Scope
Interior Wall Substrate: Drywall Wall Finishes: Wallpaper, Cove Base Floor Finishes: Vinyl Floor Tile, Carpet
T3
Construction Date: Unknown Number of Floors: One
Exterior Floor Support: Raised Wood Floor Wall Support: Wood Framing Exterior Finish: Metal Siding Roof System Type: Not In Scope
Interior Wall Substrate: Drywall Wall Finishes: Wallpaper, Cove Base Floor Finishes: Vinyl Floor Tile
T7
Facility Type: Administration, Law Enforcement Construction Date: Unknown Number of Floors: One
Exterior Floor Support: Raised Wood Floor Wall Support: Wood Framing Exterior Finish: Metal Siding Roof System Type: Not In Scope
Interior Wall Substrate: Drywall Wall Finishes: Wallpaper, Cove Base Floor Finishes: Vinyl Floor Tile
T8
Construction Date: Unknown Number of Floors: One
Exterior Floor Support: Raised Wood Floor Wall Support: Wood Framing Exterior Finish: Metal Siding Roof System Type: Not In Scope
Interior Wall Substrate: Drywall Wall Finishes: Paint, Wallpaper, Cove Base Floor Finishes: Vinyl Floor Tile
Shed
Facility Type: Storage Construction Date: Unknown Number of Floors: One
Exterior Floor Support: Concrete Floor, Raised Wood Floor Wall Support: Wood Framing Exterior Finish: Metal Siding Roof System Type: Not In Scope
Interior Wall Substrate: Inaccessible Wall Finishes: Inaccessible Floor Finishes: Inaccessible Ceiling System: Inaccessible Ceiling Finishes: Inaccessible
T9
Construction Date: Unknown Number of Floors: One
Exterior Floor Support: Raised Wood Floor Wall Support: Wood Framing Exterior Finish: Metal Siding Roof System Type: Not In Scope
Interior Wall Substrate: Drywall Wall Finishes: Paint, Wallpaper, Cove Base Floor Finishes: Vinyl Floor Tile
T10
Construction Date: Unknown Number of Floors: One
Exterior Floor Support: Raised Wood Floor Wall Support: Wood Framing Exterior Finish: Metal Siding Roof System Type: Not In Scope
Interior Wall Substrate: Drywall Wall Finishes: Paint, Wallpaper, Cove Base Floor Finishes: Carpet, Floor Tile
2.0 RESULTS
2.1 LEAD SURVEY PROCEDURES
It is GLE’s understanding that the survey was conducted to provide information needed to comply with 29 CFR Part 1926 “Lead Exposure in Construction; Interim Final Rule” for future demolition and/or renovation activities. The Scope of the “Lead Exposure in Construction;
Interim Final Rule” “…applies to all occupational exposure to lead in all construction work in which lead, in any amount, is present in an occupationally related context.” Due to the lack of a firm correlation between lead levels in paint and airborne lead levels during construction activities, OSHA has developed task-related triggers that require the implementation of the provisions required in 29 CFR Part 1926. Demolition and/or renovation activities involve tasks covered under this standard.
The limited survey was performed by observing and testing accessible painted component surfaces of the building. The sampling protocol used in this lead paint survey is a modified version of the survey methodology established by HUD. The protocol was modified to conform to the specific parameters of this project.
After the overall visual survey was completed, an inventory of painted surfaces was developed.
The surveyor then subdivided the areas into homogeneous areas of apparent similar paint history.
Sampling of the paint surfaces was performed by collecting representative paint chips. All samples were submitted to EMSL Analytical, Inc., an accredited laboratory recognized under EPA’s National Lead Laboratory Accreditation Program (NLLAP), located in Kernersville, North Carolina. These samples were analyzed by EPA Method SW 846 3050B/7000B and the results are reported in percentage of lead by weight of the paint sample (% Wt).
2.2 IDENTIFIED SUSPECT LEAD-CONTAINING PAINT
A total of 40 samples of suspect lead-containing paint were collected from the facility during the survey. The results of the laboratory analyses are included in Appendix A.
A summary of the paint chip sample analytical results is outlined in the following table.
TABLE 2.2-1: SUMMARY OF ANALYTICAL RESULTS
BUILDINGS 12, T1, T1A, T3, T7, T8, T9, T10, B26, B27 & SHED
MALCOM RANDALL VA MEDICAL CENTER – GAINESVILLE, FLORIDA
SAMPLE
# BUILDING INTERIOR OR
EXTERIOR LOCATION COMPONENT COLOR
LEAD
CONCENTRATION
(% BY WEIGHT)
L-01 Chiller Area – Section “M” Interior Chiller Area Concrete Walls White < 0.0080
L-02 Chiller Area – Section “M” Interior Chiller Area Metal Condenser Water
Piping White < 0.035
L-03 Chiller Area – Section
“M” Interior Chiller Area – South Metal South Pumps Blue 0.071
L-04 Chiller Area – Section “M” Interior Chiller Area – Between Chillers 3 and 4 Metal Condenser Pumps
P-4, P-5, and P-6 Red < 0.0093
L-05 Chiller Area Tunnel Interior East Tunnel Entrance Concrete Walls White < 0.0080
L-06 Chiller Area Tunnel Interior Tunnel Metal Beams Red/Brown < 0.0080
L-07 Chiller Area Tunnel Interior Tunnel Metal Fire Sprinkler
Piping Red < 0.014
L-08 Chiller Area Tunnel Interior Tunnel Metal Conduit Orange 0.020
L-09 Chiller Area Tunnel Interior East Tunnel Entrance Metal Rail/Ladder Turquoise < 0.0080
L-10 CLC (Building 12) Tunnel Interior Tunnel Entrance in CLC Concrete Walls Orange < 0.0080
L-11 CLC Tunnel Interior Tunnel Entrance in CLC Concrete Wall/Soffit White < 0.0085
L-12 CLC Tunnel Interior Tunnel Entrance in CLC Metal Rail White 0.11
L-13 CLC Tunnel Interior Tunnel Metal Fire Sprinkler
Piping Red < 0.046
L-14 CLC 2nd Floor Walkway Exterior Walkway Concrete Walls White < 0.0080
L-15 CLC 2nd Floor Walkway Exterior Exterior Walkway Door Metal Door Frame Brown < 0.029
L-16 CLC 2nd Floor NW Interior CLC 2nd Floor NW Drywall Walls Cream < 0.0080
L-17 CLC 2nd Floor NW Interior CLC 2nd Floor NW Hallway Metal Door Frames Blue < 0.0080
1 BOLD result indicates lead-containing paint.
2 The requirements of the OSHA Lead in Construction Standard 29CFR 1926.62 are invoked if any amount of lead is present in the sample; there is no minimum concentration.
MALCOM RANDALL VA MEDICAL CENTER – GAINESVILLE, FLORIDA
SAMPLE
# BUILDING INTERIOR OR
EXTERIOR LOCATION COMPONENT COLOR
LEAD
CONCENTRATION
(% BY WEIGHT)
L-18 CLC 2nd Floor NW Interior CLC 2nd Floor NW Rooms Metal Door Frames Cream < 0.0080
L-19 CLC 2nd Floor NW Interior CLC 2nd Floor NW Rooms Metal Lockers Purple 4.8
L-20 B26 Interior/Exterior B26 Metal Walls, Ceiling, Roof White < 0.0098
L-21 B27 Interior/Exterior B27 Metal Walls, Ceiling, Roof White < 0.0080
L-22 Trailer T1 Exterior Trailer T1 Entrances Metal Doors and Frames Light Tan < 0.0080
L-23 Trailer T1 Interior Trailer T1 Wood Doors Tan < 0.020
L-24 Trailer T1A Exterior Trailer T1A Entrances Metal Doors and Frames Light Tan < 0.018
L-25 Trailer T1A Interior Trailer T1A Wood Doors Tan < 0.010
L-26 Trailer T3 Exterior Trailer T3 Entrances Metal Doors and Frames Light Tan < 0.023
L-27 Trailer T3 Interior Trailer T3 Metal Door Frames Tan < 0.019
L-28 Trailer T3 Interior Trailer T3 Wood Doors Tan < 0.021
L-29 Trailer T7 Exterior Trailer T7 Entrances Metal Doors and Frames Light Tan < 0.0080
L-30 Trailer T7 Interior Trailer T7 Metal Door Frames Tan < 0.012
L-31 Trailer T7 Interior Trailer T7 Wood Doors Tan < 0.0088
L-32 Trailer T8 Exterior Trailer T8 Entrances Metal Doors and Frames Light Tan < 0.016
L-33 Trailer T8 Interior Trailer T8 Metal Door Frames Tan < 0.018
L-34 Trailer T8 Interior Trailer T8 Wood Doors Tan < 0.012
L-35 Trailer T8 Interior Trailer T8 Drywall/Wallpaper Walls White < 0.0080
2 The requirements of the OSHA Lead in Construction Standard 29CFR 1926.62 are invoked if any amount of lead is present in the sample; there is no
MALCOM RANDALL VA MEDICAL CENTER – GAINESVILLE, FLORIDA
SAMPLE
# BUILDING INTERIOR OR
EXTERIOR LOCATION COMPONENT COLOR
LEAD
CONCENTRATION
(% BY WEIGHT)
L-36 Trailer T9 Exterior Trailer T9 Metal Doors and Frames Tan < 0.0080
L-37 Trailer T9 Interior Trailer T9 Drywall/Wallpaper Walls White < 0.0080
L-38 Trailer T10 Exterior Trailer T10 North Metal Door and
Frame Cream < 0.0080
L-39 Trailer T10 Exterior Trailer T10 South Metal Door and
Frame Tan < 0.028
L-40 Trailer T10 Interior Trailer T10 Drywall/Wallpaper Walls White < 0.0080
2 The requirements of the OSHA Lead in Construction Standard 29CFR 1926.62 are invoked if any amount of lead is present in the sample; there is no
3.0 CONCLUSIONS AND RECOMMENDATIONS
Analytical results indicate that four of the 40 painted surfaces tested contain concentrations (% by weight) of lead within the paint greater than the laboratory’s detection limits.
Under the present OSHA lead construction standard, all identified lead-containing paint affected by construction activities falls under the requirements of 29 CFR 1926. There are no current government guidelines defining a lead paint concentration that creates a hazardous atmosphere when disturbed. Based on current OSHA guidelines, for those employees who will be disturbing lead-containing paint, their employer must make an initial determination by monitoring employee exposure if any employee is exposed to lead at or above 30 ug/m3 (8-hour
TWA).
The employer must implement OSHA prescribed protective measures until they can demonstrate that the employee exposure is not in excess of the action level. For any planned demolition or renovation where abrasive blasting, welding, cutting and/or torch burning are planned for any facility which contain lead-based paint, GLE recommends the removal of lead paint by a properly trained lead removal contractor where these activities are planned.
For all identified lead painted materials where manual demolition (e.g. drywall) manual scraping, manual sanding and heat gun applications are planned: provide workers with interim protection as outline in the OSHA Lead Construction Standard until the employee exposure monitoring indicate that that all tasks being performed are not exposing employees above the Permissible Exposure Limit (PEL).
The interim employee protection measures include but are not limited to the following:
appropriate respiratory protection; appropriate personal protective clothing and equipment;
change areas; hand washing facilities; biological monitoring; and training.
All waste generated during the lead paint removal and during subsequent manual demolition or renovation activities should be characterized by Toxicity Characteristic Leaching Procedure testing for lead for waste disposal purposes.
Additionally, the EPA Renovation, Repair, and Painting Rule requires that firms performing renovation, repair, and painting projects that disturb lead-based paint in pre-1978 homes, child care facilities and schools be certified by EPA and that they use certified renovators who are trained by EPA-approved training providers to follow lead-safe work practices.
4.0 LIMITATIONS AND CONDITIONS
Due to the inaccessibility of some building elements, it is conceivable that all potential lead-containing paint within the extents of this survey may not have been located and identified. We do warrant, however, that the investigations and methodology reflect our best efforts based upon the prevailing standard of care in the environmental industry.
APPENDIX A
Analytical Results and Chain of Custody
ConcentrationAnalyzed Weight RDL LeadClient SampleDescription Collected
Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*
EMSL Analytical, Inc.
706 Gralin Street, Kernersville, NC 27284 Phone/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com greensborolab@emsl.com
Attn: Paul Zak GLE Associates 2228 N.W. 40th Terrace Suite C Gainesville, FL 32605
Received: 05/17/18 9:20 AM
18950-00483 Alliance VAMC
Fax:
Phone: (352) 335-6648
Project:
5/14/2018Collected:
021803403 CustomerID: GLEA51B CustomerPO: 18950-00483 ProjectID:
EMSL Order:
Site: White Concrete <0.0080 % wt5/21/2018 .2658 g
021803403-0001 0.00805/14/2018L-01 % wt
Site: White Metal <0.035 % wt5/21/2018 .0579 g
021803403-0002 0.0355/14/2018L-02 % wt
Site: Blue Metal
0.071 % wt5/21/2018 .1402 g
021803403-0003 0.0145/14/2018L-03 % wt
Site: Red Metal <0.0093 % wt5/21/2018 .2151 g
021803403-0004 0.00935/14/2018L-04 % wt
Site: White Concrete <0.0080 % wt5/21/2018 .2619 g
021803403-0005 0.00805/14/2018L-05 % wt
Site: Red/Brown Metal <0.0080 % wt5/21/2018 .2543 g
021803403-0006 0.00805/14/2018L-06 % wt
Site: Red Metal <0.014 % wt5/21/2018 .1439 g
021803403-0007 0.0145/14/2018L-07 % wt
Site: Orange Metal
0.020 % wt5/21/2018 .1497 g
021803403-0008 0.0135/14/2018L-08 % wt
Site: Turquoise Metal <0.0080 % wt5/21/2018 .3119 g
021803403-0009 0.00805/14/2018L-09 % wt
Site: Orange Concrete <0.0080 % wt5/21/2018 .3231 g
021803403-0010 0.00805/14/2018L-10 % wt
Site: White Concrete <0.0085 % wt5/21/2018 .2349 g
021803403-0011 0.00855/14/2018L-11 % wt
Page 1 of 4Test Report PB w/RDL-7.32.3 Printed: 5/21/2018 4:16:22 PM
James Cole, Laboratory Manager or other approved signatory
*Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.010 % wt based on the minimum sample weight per our SOP. Unless noted, results in this report are not blank corrected. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities. Samples received in good condition unless otherwise noted. "<" (less than) result signifies that the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. The QC data associated with the sample results included in this report meet the recovery and precision requirements unless specifically indicated otherwise.
Definitions of modifications are available upon request.
Samples analyzed by EMSL Analytical, Inc. Kernersville, NC EMSL Lab ID 102564 is accredited by the AIHA Laboratory Accreditation Program (AIHA-LAP), LLC in the Environmental Lead accreditation program for Lead in Paint Chips.
Initial report from 05/21/2018 16:16:22 http://www.EMSL.com mailto:greensborolab@emsl.com
EMSL Analytical, Inc.
706 Gralin Street, Kernersville, NC 27284 Phone/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com greensborolab@emsl.com
Attn: Paul Zak GLE Associates 2228 N.W. 40th Terrace Suite C Gainesville, FL 32605
Received: 05/17/18 9:20 AM
18950-00483 Alliance VAMC
Fax:
Phone: (352) 335-6648
Project:
5/14/2018Collected:
021803403 CustomerID: GLEA51B CustomerPO: 18950-00483 ProjectID:
EMSL Order:
Site: White Metal
0.11 % wt5/21/2018 .252 g
021803403-0012 0.00805/14/2018L-12 % wt
Site: Red Metal <0.046 % wt5/21/2018 .0435 g
021803403-0013 0.0465/14/2018L-13 % wt
Site: White Concrete <0.0080 % wt5/21/2018 .2777 g
021803403-0014 0.00805/14/2018L-14 % wt
Site: Brown Metal <0.029 % wt5/21/2018 .0678 g
021803403-0015 0.0295/14/2018L-15 % wt
Site: Cream Drywall <0.0080 % wt5/21/2018 .4055 g
021803403-0016 0.00805/14/2018L-16 % wt
Site: Blue Metal <0.0080 % wt5/21/2018 .2876 g
021803403-0017 0.00805/14/2018L-17 % wt
Site: Cream Metal <0.0080 % wt5/21/2018 .33 g
021803403-0018 0.00805/14/2018L-18 % wt
Site: Purple Metal
4.8 % wt5/21/2018 .0579 g
021803403-0019 0.355/14/2018L-19 % wt
Site: White Metal <0.0098 % wt5/21/2018 .2034 g
021803403-0020 0.00985/14/2018L-20 % wt
Site: White Metal <0.0080 % wt5/21/2018 .2741 g
021803403-0021 0.00805/14/2018L-21 % wt
Site: Light Tan Metal <0.0080 % wt5/21/2018 .3747 g
021803403-0022 0.00805/14/2018L-22 % wt
Page 2 of 4Test Report PB w/RDL-7.32.3 Printed: 5/21/2018 4:16:22 PM
James Cole, Laboratory Manager or other approved signatory
*Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.010 % wt based on the minimum sample weight per our SOP. Unless noted, results in this report are not blank corrected. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities. Samples received in good condition unless otherwise noted. "<" (less than) result signifies that the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. The QC data associated with the sample results included in this report meet the recovery and precision requirements unless specifically indicated otherwise.
Definitions of modifications are available upon request.
Samples analyzed by EMSL Analytical, Inc. Kernersville, NC EMSL Lab ID 102564 is accredited by the AIHA Laboratory Accreditation Program (AIHA-LAP), LLC in the Environmental Lead accreditation program for Lead in Paint Chips.
Initial report from 05/21/2018 16:16:22
EMSL Analytical, Inc.
706 Gralin Street, Kernersville, NC 27284 Phone/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com greensborolab@emsl.com
Attn: Paul Zak GLE Associates 2228 N.W. 40th Terrace Suite C Gainesville, FL 32605
Received: 05/17/18 9:20 AM
18950-00483 Alliance VAMC
Fax:
Phone: (352) 335-6648
Project:
5/14/2018Collected:
021803403 CustomerID: GLEA51B CustomerPO: 18950-00483 ProjectID:
EMSL Order:
Site: Tan Wood <0.020 % wt5/21/2018 .101 g
021803403-0023 0.0205/14/2018L-23 % wt
Site: Light Tan Metal <0.018 % wt5/21/2018 .1099 g
021803403-0024 0.0185/14/2018L-24 % wt
Site: Tan Wood <0.010 % wt5/21/2018 .1967 g
021803403-0025 0.0105/14/2018L-25 % wt
Site: Light Tan Metal <0.023 % wt5/21/2018 .0855 g
021803403-0026 0.0235/14/2018L-26 % wt
Site: Tan Metal <0.019 % wt5/21/2018 .1052 g
021803403-0027 0.0195/14/2018L-27 % wt
Site: Tan Wood <0.021 % wt5/21/2018 .096 g
021803403-0028 0.0215/14/2018L-28 % wt
Site: Light Tan Metal <0.0080 % wt5/21/2018 .2659 g
021803403-0029 0.00805/14/2018L-29 % wt
Site: Tan Metal <0.012 % wt5/21/2018 .1685 g
021803403-0030 0.0125/14/2018L-30 % wt
Site: Tan Wood <0.0088 % wt5/21/2018 .2277 g
021803403-0031 0.00885/14/2018L-31 % wt
Site: Light Tan Metal <0.016 % wt5/21/2018 .1288 g
021803403-0032 0.0165/14/2018L-32 % wt
Site: Tan Metal <0.018 % wt5/21/2018 .1121 g
021803403-0033 0.0185/14/2018L-33 % wt
Page 3 of 4Test Report PB w/RDL-7.32.3 Printed: 5/21/2018 4:16:22 PM
James Cole, Laboratory Manager or other approved signatory
*Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.010 % wt based on the minimum sample weight per our SOP. Unless noted, results in this report are not blank corrected. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities. Samples received in good condition unless otherwise noted. "<" (less than) result signifies that the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. The QC data associated with the sample results included in this report meet the recovery and precision requirements unless specifically indicated otherwise.
Definitions of modifications are available upon request.
Samples analyzed by EMSL Analytical, Inc. Kernersville, NC EMSL Lab ID 102564 is accredited by the AIHA Laboratory Accreditation Program (AIHA-LAP), LLC in the Environmental Lead accreditation program for Lead in Paint Chips.
Initial report from 05/21/2018 16:16:22
EMSL Analytical, Inc.
706 Gralin Street, Kernersville, NC 27284 Phone/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com greensborolab@emsl.com
Attn: Paul Zak GLE Associates 2228 N.W. 40th Terrace Suite C Gainesville, FL 32605
Received: 05/17/18 9:20 AM
18950-00483 Alliance VAMC
Fax:
Phone: (352) 335-6648
Project:
5/14/2018Collected:
021803403 CustomerID: GLEA51B CustomerPO: 18950-00483 ProjectID:
EMSL Order:
Site: Tan Wood <0.012 % wt5/21/2018 .166 g
021803403-0034 0.0125/14/2018L-34 % wt
Site: White Drywall/Wallpaper <0.0080 % wt5/21/2018 .2499 g
021803403-0035 0.00805/14/2018L-35 % wt
Site: Tan Metal <0.0080 % wt5/21/2018 .3043 g
021803403-0036 0.00805/14/2018L-36 % wt
Site: White Drywall/Wallpaper <0.0080 % wt5/21/2018 .272 g
021803403-0037 0.00805/14/2018L-37 % wt
Site: Cream Metal <0.0080 % wt5/21/2018 .2819 g
021803403-0038 0.00805/14/2018L-38 % wt
Site: Tan Metal <0.028 % wt5/21/2018 .0708 g
021803403-0039 0.0285/14/2018L-39 % wt
Site: White Drywall/Wallpaper <0.0080 % wt5/21/2018 .3132 g
021803403-0040 0.00805/14/2018L-40 % wt
Page 4 of 4Test Report PB w/RDL-7.32.3 Printed: 5/21/2018 4:16:22 PM
James Cole, Laboratory Manager or other approved signatory
*Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.010 % wt based on the minimum sample weight per our SOP. Unless noted, results in this report are not blank corrected. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities. Samples received in good condition unless otherwise noted. "<" (less than) result signifies that the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. The QC data associated with the sample results included in this report meet the recovery and precision requirements unless specifically indicated otherwise.
Definitions of modifications are available upon request.
Samples analyzed by EMSL Analytical, Inc. Kernersville, NC EMSL Lab ID 102564 is accredited by the AIHA Laboratory Accreditation Program (AIHA-LAP), LLC in the Environmental Lead accreditation program for Lead in Paint Chips.
Initial report from 05/21/2018 16:16:22
OrderID: 021803403
APPENDIX B
Personnel and Laboratory Qualifications
GLE Associates, Inc.
has fulfilled the requirements of the Toxic Substances Control Act (TSCA) Section 402, and has received certification to conduct lead-based paint activities pursuant to 40 CFR Part 745.226
All EPA Administered Lead-based Paint Activities Program States, Tribes and Territories
This certification is valid from the date of issuance and expires March 03, 2021
Certification #
LBP-2060-1
Issued On
January 25, 2018
Michelle Price, Chief
Lead, Heavy Metals, and Inorganics Branch
AIHA Laboratory Accreditation Programs, LLC acknowledges that
EMSL Analytical, Inc.
706 Gralin Street, Kernersville, NC 27284
Laboratory ID: 102564 along with all premises from which key activities are performed, as listed above, has fulfilled the requirements of the AIHA Laboratory Accreditation Programs (AIHA-LAP), LLC accreditation to the ISO/IEC 17025:2005 international standard, General Requirements for the Competence of Testing and Calibration Laboratories in the following:
LABORATORY ACCREDITATION PROGRAMS
INDUSTRIAL HYGIENE Accreditation Expires:
ENVIRONMENTAL LEAD Accreditation Expires: September 01, 2018 ENVIRONMENTAL MICROBIOLOGY Accreditation Expires:
FOOD Accreditation Expires:
UNIQUE SCOPES Accreditation Expires:
Specific Field(s) of Testing (FoT)/Method(s) within each Accreditation Program for which the above named laboratory maintains accreditation is outlined on the attached Scope of Accreditation. Continued accreditation is contingent upon successful on-going compliance with ISO/IEC 17025:2005 and AIHA-LAP, LLC requirements. This certificate is not valid without the attached Scope of Accreditation. Please review the AIHA- LAP, LLC website (www.aihaaccreditedlabs.org) for the most current Scope.
William Walsh, CIH Chairperson, Analytical Accreditation Board
Cheryl O. Morton Managing Director, AIHA Laboratory Accreditation Programs, LLC
Revision 15: 03/30/2016 Date Issued: 09/29/2016 http://www.aihaaccreditedlabs.org/
| EMSL Kernersville Lead 9-1-18.pdf |
| EMSL Analytical, Inc. |
| 706 Gralin Street, Kernersville, NC 27284 |
| Laboratory ID: 102564 |
| LABORATORY ACCREDITATION PROGRAMS |