This file is a Los Angeles Fire Department Fire Protection Equipment Performance Report for an emergency power generator initial test conducted on 09/11/2024 at 351 E Temple St. The report details a failed test with two specific deficiencies: 1) the transfer time to secondary power exceeded 10 seconds, and 2) an exit sign on the 3rd floor near room A328 had a broken face, making it not clearly visible. The generator is a Marathon-manufactured 600 kW diesel-powered unit located in the electrical room on the P-2 level, serving the entire building's life safety systems including emergency exit signs, exit path lighting, fire alarm, and elevator systems. The generator has three transfer switches and a 5000-gallon main fuel tank with a 100-gallon day tank. The test was conducted as part of ensuring the emergency power system meets Los Angeles Fire Department Chief's Regulation No. 4 requirements and NFPA standards, with a requirement to correct identified defects within 30 days of the initial test.
View the file
Other files
Show all 41
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TEST SITE INFORMATION
TEST SITE ADDRESS: (STREET) (CITY) (STATE) (ZIP) TEST SITE PHONE:
351 E TEMPLE ST LOS ANGELES CA 90012-3328
OCCUPANCY TYPE: NUMBER OF STORIES: YEAR BUILT: CONSTRUCTION TYPE: SQUARE FOOTAGE:
B - Business 5 1973 Type II 105000
RESPONSIBLE PARTY
NAME: (LAST, FIRST, MI) TITLE: FIRM OR D.B.A.:
HUNT, EDWARD RESPONSIBLE PERSON VA LAACC
MAILING ADDRESS: (STREET) (CITY) (STATE) (ZIP) PHONE:
351 E TEMPLE LOS ANGELES CA 90012 (818) 891-7711
TEST INFORMATION
INITIAL TEST DATE: TESTING AGENCY: PHONE:
09/11/2024
MAILING ADDRESS: (STREET) (CITY) (STATE) (ZIP)
TEST RESULTS
☐ PASS ☒ FAIL
All sections below shall be found in the following pages of this report.
SECTIONS:
I. BUILDING DESCRIPTION
II. SYSTEM DESCRIPTION
III. FINDINGS
IV. TESTING PROCEDURES/WORKSHEETS
I HEREBY CERTIFY THAT THE FIRE PROTECTION EQUIPMENT LISTED ABOVE HAS BEEN FULLY TESTED IN ACCORDANCE WITH THE CHIEF'S REGULATION NO. 4 OF THE LOS ANGELES FIRE CODE AND THAT THE RESULTS ARE ACCURATELY LISTED ABOVE AND THE
EQUIPMENT IS FULLY OPERABLE EXCEPT AS NOTED.
TESTER'S NAME: CERTIFICATE #: EXPIRATION DATE: SIGNATURE:
10/31/2026
REPAIR AND RETEST: IF DEFECTS ARE FOUND IN EQUIPMENT TESTED, CORRECTION OF SUCH DEFECTS SHALL COMMENCE FORTHWITH AND SHALL BE COMPLETED AS SOON AS
POSSIBLE, BUT IN EVERY CASE WITHIN 30 DAYS OF INITIAL TEST. THE F-340RT SHALL BE USED TO DOCUMENT THE RETEST OF DEFECTS FOUND IN SCTION III. A COPY OF
SECTION III OF THIS REPORT SHALL BE ATTACHED TO THE F-340RT PRIOR TO SUBMITTING TO THE FIRE DEPARTMENT.
REPORT SUBMITTAL INFORMATION:
ALL REPORTS ARE REQUIRED TO BE SUBMITTED TO THE LOS ANGELES CITY FIRE DEPARTMENT VIA THE COMPLIANCE ENGINE
WITHIN 7 DAYS OF TEST COMPLETION.
ENTERED BY: ENTERED DATE: ENTERED TIME:
09/17/2024 3:12 PM
LOS ANGELES FIRE DEPARTMENT
FIRE PROTECTION EQUIPMENT PERFORMANCE REPORT
Emergency Power Generator - Initial Test
Test Report Number
6301228
TRN 6301228 Printed Mon Sep 16 12:09:43 CDT 2024
Section I - Building Description:
CHARACTERISTICS
PRIMARY OCCUPANCY TYPE B - Business FIRE CONTROL ROOM: ☐YES ☒NO
SECONDARY OCCUPANCY TYPE I-2 ELEVATOR INFORMATION: CARS BANKS
TYPE OF BUSINESS CONDUCTED PASSENGER 4 1
☐ Apartment/Condo ☐ Museum
☐ Bar/Restaurant ☐ Parking Structure
☐ Church ☒ Office Space
☐ Schools ☐ Repair Garage
☐ Day Care ☐ Retail
☐ Detention Facility ☐ Skilled Nursing
☐ Group Home ☐ Telecommunications
☐ Hospital ☐ Theatre
☐ Hotel/Motel ☐ Warehouse
☒ Medical Office/Clinic ☒ Other: VETERANS
OUTPATIENT CLINIC
FREIGHT
PARKING 2 1
NUMBER OF STAIRWAYS: 5
FIRE PUMP(S): ☒YES ☐NO
LOCATION: P-2
EMERGENCY GENERATOR(S): ☒YES ☐NO
LOCATION: P-1
PARKING STRUCTURE:
☒ UNDERGROUND ☐ DETACHED ☒ ATTACHED
NUMBER OF LEVELS BELOW GROUND: 2
UNIQUE PROPERTY FEATURES: TYPES OF OCCUPANCIES BELOW GROUND:
FULLY SPRINKLERED OUTPATIENT VETERNAS CLINIC
WITH RISER AT SOUTH STAIR #5.
S-2, PARKING
LOS ANGELES FIRE DEPARTMENT
FIRE PROTECTION EQUIPMENT PERFORMANCE REPORT
THIS PAGE BY ITSELF IS NOT A COMPLETE REPORT
Test Report Number
6301228
INITIAL TEST DATE: TEST SITE ADDRESS: (STREET NUMBER AND STREET NAME)
09/11/2024 351 E TEMPLE ST
EQUIPMENT TESTED:
Emergency Power Generator - Initial Test
The owner/owner(s) representative shall ensure that the appropriate permits have been secured prior to any repairs being performed.
A copy of this section shall accompany the F-340RT in all cases.
Section III - Findings: ☒SYSTEM DEFECTS FOUND ☐NO SYSTEM DEFECTS FOUND
GRAY AREAS SHALL BE FILLED OUT BY CERTIFIED TESTER PERFORMING RETEST
DEFECT # ITEM #
(SECTION IV) DESCRIPTION LOCATION RETEST
ONLY
1 3.5 Transfer time to secondary power is within 10 seconds of primary power loss.
Fail
Transfer switch ☐PASS
2 3.9 All exit signs and directional exit signs were illuminated and clearly visible within 100ft of each sign in accordance with LAFD acceptance standards.
Fail
3rd floor by A328 broken face on sign. ☐PASS
INITIAL TEST PERFORMED BY
TESTER'S NAME: CERTIFICATE #: EXPIRATION DATE: SIGNATURE:
10/31/2026
PHONE NUMBER OF TESTING AGENCY: TESTING AGENCY: STATE: ZIP:
RETEST DATE: RETEST PERFORMED BY
RE-TESTER'S NAME: CERTIFICATE #: EXPIRATION DATE: RE-TESTER'S SIGNATURE: PHONE NUMBER:
LOS ANGELES FIRE DEPARTMENT
FIRE PROTECTION EQUIPMENT PERFORMANCE REPORT
THIS PAGE BY ITSELF IS NOT A COMPLETE REPORT
Test Report Number
6301228
INITIAL TEST DATE: TEST SITE ADDRESS: (STREET NUMBER AND STREET NAME)
09/11/2024 351 E TEMPLE ST
EQUIPMENT TESTED:
Emergency Power Generator - Initial Test
All testing procedures below were performed in accordance with the Los Angeles Fire Department Chief's Regulation No. 4 requirements, applicable sections of NFPA 110 and other approved publications.
ITEM # DESCRIPTION
Section II - EMERGENCY AND STANDBY POWER SYSTEMS - GENERATOR DESCRIPTION:
Manufacturer of Generator:
Marathon
Rating (KW):
Serial No.:
xm 3854767
Manufacturer of Engine Driver:
powerpack
Serial No.:
91237306
Type of Fuel for Driver:
diesel
Capacity of Main Fuel Tank:
Capacity of Day Tank:
Main Disconnect Location(s):
electrical room p-2
Remote Annunciator Location:
Number of Transfer Switches:
Required Life Safety Equipment Served By the Generator:
☒Emergency Exit & Directional Signs
☒Exit Path Lighting
☒Electric Fire Pump(s) Jockey Pump(s)
☐Stairwell Pressurization
☐Smoke Management
☒Fire Alarm
☐Window Washing Equipment
☐Circuits for Life Support (Red Plugs)
☒Elevator Cars
Exit Path Lighting Locations:
☒Stairwells
☒Garage Area
☒Corridors/Hallways
TESTER'S NAME: CERTIFICATE #: EXPIRATION DATE: PHONE NUMBER OF TESTING AGENCY:
10/31/2026
LOS ANGELES FIRE DEPARTMENT
FIRE PROTECTION EQUIPMENT PERFORMANCE REPORT
THIS PAGE BY ITSELF IS NOT A COMPLETE REPORT
Test Report Number
6301228
INITIAL TEST DATE: TEST SITE ADDRESS: (STREET NUMBER AND STREET NAME)
09/11/2024 351 E TEMPLE ST
EQUIPMENT TESTED:
Emergency Power Generator - Initial Test
ITEM # DESCRIPTION
Electric Fire Pump(s) Jockey Pump(s) Quantity:
Stairwell Pressurization - Number of:
Fire department connection (FDC) locations:
Emergency Power Generator Serves:
☒Entire building
☐Multiple buildings
☐Partial areas
If the Emergency Power Generator serves multiple buildings, give addresses:
If the Emergency Power Generator serves partial areas, give areas:
1.0 NOTIFICATION PASS FAIL N/A
1.1 Fire Department dispatch, supervising station, & building occupants notified prior to the start of the test.
Yes
2.0 INSPECTION / PRE-START CHECK PASS FAIL N/A
2.1 Single line diagram provided by the owner/building representative. ☒ ☐ ☐
2.2 Operating instruction manual provided in a secure location near the equipment. ☒ ☐ ☐
2.3 Gauges on the control panel not damaged and appear to be in working order. ☒ ☐ ☐
2.4 Lamps/Lights are in place and appear to be undamaged. ☒ ☐ ☐
2.5 Lamps/Lights are lit or verified to be operational. ☒ ☐ ☐
2.6 Timer reading/meter checked and logged. ☒ ☐ ☐
2.7 Fluid levels checked, oil, water, fuel. ☒ ☐ ☐
2.8 Batteries are free of physical damage, leaks, loose connections, and corrosion. ☒ ☐ ☐
2.9 Battery hydrometer check, water level & voltage readings. ☒ ☐ ☐
2.10 Generator is in the automatic mode. ☒ ☐ ☐
2.11 Generator is in a "Cold Start" condition (has not been started within 12 hours). ☒ ☐ ☐
3.0 OPERATIONAL TESTS PASS FAIL N/A
3.1 All "Life Safety" systems and equipment are running when test initiated. ☒ ☐ ☐
3.2 Main power was disconnected at the main disconnect/breaker. ☒ ☐ ☐
3.3 Delay of engine start one second minimum. ☒ ☐ ☐
Delay time:
TESTER'S NAME: CERTIFICATE #: EXPIRATION DATE: PHONE NUMBER OF TESTING AGENCY:
10/31/2026
LOS ANGELES FIRE DEPARTMENT
FIRE PROTECTION EQUIPMENT PERFORMANCE REPORT
THIS PAGE BY ITSELF IS NOT A COMPLETE REPORT
Test Report Number
6301228
INITIAL TEST DATE: TEST SITE ADDRESS: (STREET NUMBER AND STREET NAME)
09/11/2024 351 E TEMPLE ST
EQUIPMENT TESTED:
Emergency Power Generator - Initial Test
3.4 Battery cranking time is 45 seconds or less or 3 cycles of 15 seconds. ☒ ☐ ☐
3.5 Transfer time to secondary power is within 10 seconds of primary power loss. ☐ ☒ ☐
Transfer time:
11.5
3.6 Standby power up and operating within 60 seconds. ☒ ☐ ☐
3.7 All Life Safety systems continued to operate properly for the duration of the test. ☒ ☐ ☐
3.8 All exit path lighting was sufficient enough to readily find, distinguish, and safely use the exit path in accordance with LAFD acceptance standards. ☒ ☐ ☐
3.9 All exit signs and directional exit signs were illuminated and clearly visible within 100ft of each sign in accordance with LAFD acceptance standards. ☐ ☒ ☐
3.10 Exit signs illuminated from an external source measured 5 foot candles at the sign. ☒ ☐ ☐
3.11 Generator ran a minimum of 30 minutes. ☒ ☐ ☐
3.12 Delay on re-transfer from the secondary power to primary power is (minutes). ☒ ☐ ☐
50.0
3.13 Time delay on engine shut-down 5-minute minimum. ☒ ☐ ☐
3.14 Oil pressure ☒ ☐ ☐
3.15 Water temperature ☒ ☐ ☐
3.16 Fuel leaks ☒ ☐ ☐
3.17 Exhaust leaks ☒ ☐ ☐
3.18 Unusual noises ☒ ☐ ☐
4.0 AREAS TESTED PASS FAIL N/A
4.1 Storage areas ☒ ☐ ☐
4.2 Mechanical rooms ☒ ☐ ☐
4.3 Electrical rooms ☒ ☐ ☐
4.4 Conference rooms ☒ ☐ ☐
4.5 Restrooms ☒ ☐ ☐
4.6 Parking garage areas ☒ ☐ ☐
4.7 Exit corridors ☒ ☐ ☐
4.8 Stairwells ☒ ☐ ☐
4.9 Elevator lobbies ☒ ☐ ☐
4.10 Elevator cars ☒ ☐ ☐
4.11 Fire pump room ☒ ☐ ☐
4.12 Generator room ☒ ☐ ☐
4.13 Elevator machine rooms ☒ ☐ ☐
4.14 Fire control room ☒ ☐ ☐
4.16 Other ☐ ☐ ☐
TESTER'S NAME: CERTIFICATE #: EXPIRATION DATE: PHONE NUMBER OF TESTING AGENCY:
10/31/2026
LOS ANGELES FIRE DEPARTMENT
FIRE PROTECTION EQUIPMENT PERFORMANCE REPORT
THIS PAGE BY ITSELF IS NOT A COMPLETE REPORT
Test Report Number
6301228
INITIAL TEST DATE: TEST SITE ADDRESS: (STREET NUMBER AND STREET NAME)
09/11/2024 351 E TEMPLE ST
EQUIPMENT TESTED:
Emergency Power Generator - Initial Test
5.0 CHECKS AFTER SHUTDOWN PASS FAIL N/A
5.1 New timer reading checked and logged. ☒ ☐ ☐
5.2 Fuel tank(s) checked. ☒ ☐ ☐
5.3 Generator returned to auto mode. ☒ ☐ ☐
5.4 All controls returned to normal position. ☒ ☐ ☐
5.5 Entries have been made into the generator log. ☒ ☐ ☐
AREAS/DEVICES/APPLIANCES NOT ACCESSIBLE FOR TESTING
A minimum of 90% of testing is required. If less than 90% testing is conducted do not submit this report.
Description:
END OF REPORT
ALL FINDINGS INDICATING “FAIL” ARE LISTED IN SECTION III (YELLOW SECTION) AND HAVE BEEN POPULATED WITH THE ITEM
DESCRIPTION, NUMBER AND LOCATION.
THE RESULTS ARE ACCURATELY LISTED AND THE EQUIPMENT IS FULLY OPERABLE EXCEPT AS NOTED. YOU ARE A CERTIFIED REGULATION NO. 4 TESTER WITH A VALID CERTIFICATION OR HAVE BEEN AUTHORIZED TO SUBMIT THE INFORMATION ON BEHALF
OF A CERTIFIED CHIEFS REGULATION NO. 4 TESTER.
I ACCEPT
☒Yes
TESTER'S NAME: CERTIFICATE #: EXPIRATION DATE: PHONE NUMBER OF TESTING AGENCY:
10/31/2026
LOS ANGELES FIRE DEPARTMENT
FIRE PROTECTION EQUIPMENT PERFORMANCE REPORT
THIS PAGE BY ITSELF IS NOT A COMPLETE REPORT
Test Report Number
6301228
INITIAL TEST DATE: TEST SITE ADDRESS: (STREET NUMBER AND STREET NAME)
09/11/2024 351 E TEMPLE ST
EQUIPMENT TESTED:
Emergency Power Generator - Initial Test
File details come from the government source that posted it. Updated .