309 East 10th Drive Mesa, Arizona 85210
Project Name: Spec Section #:
Job Number: Submittal #:
Date: Revision #:
Spec Section Title:
Submittal Title:
Contractor Stamp:
Architect / Consultant Stamp:
VA Stamp:
Remarks:
From:
SUBMITTAL
Joey Tapaha
07 53 23
07-008
Ethylene-Propylene-Diene-Monomer Roofing
Ethylene-Propylene-Diene-Monomer Roofing
Clinical Lab and Pharmacy Building
16130
1/10/2018
REVIEWED
By Joey Tapaha at 11:52 am, 1/10/18
Notes:
1. Clarify length of warranty (p. 66 does not indicate)
2. Provide crickets per roof plan at HVAC units.
3. Provide blocking as required by installer.
4. GC coordinate pre-roofing inspection and obtain written acceptance of substrate by installer.
X
Iliamar Isaac 02/05/18
Approved as noted - notify COR when pre-roof inspection is scheduled.
VA COR Randall Fenton 2/14/2018
APPROVED AS NOTEDAPPROVED AS NOTED
Job # 5101-7-229
P R O G R E S S I V E
R O O F I N G
23 North 35th Avenue Phoenix, AZ 85009
(602) 278-4900 fax (602) 278-6896 estmg. fax (602) 278-8014
Roofing & Roof Top Insulation
Submittals 07 22 00 & 07 53 23
Clinical Lab & Pharmacy Building
January 8, 2018
MEMBER
NATIONAL
ROOFING
CONTRACTORS
ASSOCIATIONS
Progressive Roofing
23 North 35th Avenue Phoenix, AZ 85009
(602) 278-4900 fax (602) 278-6896 estimating fax (602) 278-8014
047565 C-42 (AZ)
073961 L-42 (AZ)
082788 C-05 (AZ)
082792 BE (AZ)
082793 AE (AZ)
577294 C-39 (CA)
034331 GS-21 (NM)
22525 C-15A (NV)
Clinical Lab & Pharmacy Building
07 22 00 Roof Top Insulation
07 53 23 Roofing
SYSTEM:
Minimum Roof Design Requirements page
Specification Section 07 22 00 Checked Specification Section 07 53 23 Checked Carlisle Introduction & Approval Letter Carlise Product Data Sheets Testing and Warrenty Carlisle Documents Safety Data Sheets Progressive Roofing 5 year Contractor’s Warranty Taper Materials and Layout Membrane Sheet Layout & Roof Plan Roofing Details
System Overview
Product Reviews
Product Data Sheets
Testing and Warranty
Documents
V
EPDM Roofing Submittal
Grant Gosselin Carlisle Syntec 480-326-9042 grant.gosselin@carlislesyntec.com
Northern Arizona VA Health Care System Clinical Lab & Pharmacy Building
Prescott, AZ Progressive Roofing
November 21, 2017
PROGRESSIVE SERVICES INC.
23 NORTH 35TH AVENUE
PHOENIX, AZ 85009
US
Project: Northern AZ VA Health Care System
To Whom It May Concern:
This letter is to confirm that PROGRESSIVE SERVICES INC. in PHOENIX, AZ is a Carlisle
Authorized Applicator.
This Applicator has been awarded with the following awards:
ESP 2009, FleeceBACK Champions
If you should have any further questions, please feel free to contact me.
Sincerely, Richey, Derek
SW Region Sales Manager
/ems
System Features & Benefi ts:
» 25 years of proven performance
» Industry leading UV resistance of 25,200 kJ/m2 for white membranes
» Reduces air conditioning costs in warmer climates
» 540% elongation results in superior hail damage resistance
» Lowest global warming potential, acid rain and smog impact according to EPA’s TRACI model
» Full thickness of weathering material, no internal scrim
» Zero (no growth) rating for fungal growth
4 5
FOR TEAR OFF OPTIONS REFER TO NEW CONSTRUCTION ABOVE.
For current code approvals and warranties, visit Carlisle’s web site or contact a design analyst.
* Refer to Carlisle’s Adhered Design Criteria Portion of the current specifi cations for requirements.
Sure-White EPDM Membrane with Factory-Applied Tape (FAT™)
Carlisle Bonding Adhesive
Carlisle Fasteners and Plates
Acceptable Insulation
Approved Roof Deck
EPDM Membranes for Fully Adhered Roofi ng Systems are available in the following:
Color White
Thicknesses (mils) 60 and 90
Standard Widths 10' (90-mil), 16½', 20', 25', 30'
Standard Lengths 100'
New Construction Re-roofi ng
Existing or New Deck Type Steel Plywood or OSB
Lt. Wt.
Concrete
Structural Concrete
Wood Planks
Gypsum & Fibrous Cement
Smooth- Surfaced
BUR
Gravel- Surfaced
BUR
Existing Single-Ply
Insulation Required Yes No *Refer to
Specs No No Yes No Yes Yes
Recommended Insulations Carlisle Polyiso, OSB or SecurShield™ HD Cover Board Over Polystyrene Refer to New Construction
Insulation Attached By FAST™ Adhesive (non-penetrating) or Carlisle Fasteners and Plates Refer to New Construction
Membrane Attached By Carlisle-Approved Bonding Adhesive Refer to New Construction
Typical Application
E X P E R I E N C E T H E C A R L I S L E D I F F E R E N C E
Fully Adhered Roofi ng Systems
800-479-6832 | P.O. Box 7000 | Carlisle, PA 17013 | Fax: 717-245-7053 | www.carlislesyntec.com
Installation
Carlisle’s Sure-White Fully Adhered Roofi ng Systems utilize 60- or 90-mil non-reinforced membranes that meet ENERGY STAR®*, CRRC, LEED® and Title 24 guidelines designed to reduce air conditioning costs.
Insulation is either mechanically fastened to the roof deck every 2 square feet or adhered with FAST Adhesive or other Carlisle-approved insulation adhesive. Membrane is adhered to the insulation with Carlisle-approved bonding adhesive. Adjoining sheets of Sure-White EPDM are spliced together a minimum of 3" using Carlisle’s SecurTAPE™ or FAT™ seam technology.
The above information represents a typical Carlisle Fully Adhered Roofi ng System. Refer to Carlisle’s published specifi cations and details for more complete information.
Membrane and System Strengths » Carlisle manufactures all major components of the roof system
» Dimensionally stable in both hot and cold climates
» FAT Seam Technology and Pressure-Sensitive Flashing accessories enhance workmanship quality
» Meets ENERGY STAR guidelines, is CRRC certifi ed and can contribute toward LEED credit requirements designed to reduce air conditioning costs primarily in warmer southern climates*
Caution: A heating penalty may be associated with white roofs in central and northern climates and may be more prone to condensation accumulation.
» 60-mil and 90-mil membranes available for up to 25 and 30 year warranties
» 60-mil available in 10', 16 ½', 20', 25' and 30' widths, which reduces the total number of seams required and improves productivity. 90-mil available in 10' width
» Carlisle’s Fully Adhered Roof System offers design fl exibility, addresses unconventional building confi gurations and conforms to steeply sloped roof designs
» Carlisle’s Low-VOC Bonding Adhesive has a signifi cant cold weather fl ash off time advantage
» FleeceBACK® options available
System Codes
» UL Class A and B ratings are available over most deck types.
» FM uplift ratings of up to 1-120 are available.
For code specifi cs, refer to Carlisle’s Code Approval Guide.
Quality Assurance
Carlisle Authorized Applicators have been trained to install Fully Adhered Roofi ng Systems.
Inspection
Upon installation completion, and prior to the issuance of a membrane system warrranty, an inspection will be conducted by a Carlisle Field Service Representative.
Warranty
Consult your Authorized Applicator or Carlisle Manufacturer’s Representative/Distributor for associated warranty charges.
This system properly installed and inspected on a commercial project may receive:
» A 10-, 15-, 20-, 25- or 30-year (90-mil required) Golden Seal™ Total System Warranty when all materials used for the roofi ng installation are manufactured or marketed by Carlisle.
» A 1" hail warranty is available with 60-mil EPDM and a 2" hail warranty is available with 90-mil EPDM.
» A maximum peak gust wind speed coverage of 55mph is standard.
Additional coverage up to 120 mph is available.
For more specifi cs or for International warranty programs, contact Carlisle.
E X P E R I E N C E T H E C A R L I S L E D I F F E R E N C E
800-479-6832 | P.O. Box 7000 | Carlisle, PA 17013 | Fax: 717-245-7053 | www.carlislesyntec.com
11.25.14 © 2014 Carlisle.
REPRINT CODE: 601762 - “Sure-White Fully Adhered System Sheet”
Carlisle, Sure-White, FleeceBACK, FAST, SecurTAPE, FAT, SecurShield and Golden Seal are trademarks of Carlisle. ENERGY STAR is a registered trademark owned by the U.S. Government. *ENERGY STAR qualifi cation only valid in the U.S. LEED is a registered trademark owned by the U.S. Green Building Council.
Fully Adhered Roofi ng Systems
*The ENERGY STAR program recommends using the Roof Savings Calculator (rsc.ornl.gov) to determine if a white refl ective roof will save or cost you money compared to a dark-colored roof depending on geographic climate conditions, building location, and other variables.
Product Data Sheets
800-479-6832 | P.O. Box 7000 | Carlisle, PA 17013 | Fax: 717-245-7053 | www.carlislesyntec.com
E X P E R I E N C E T H E C A R L I S L E D I F F E R E N C E
Membranes
Overview
Sure-White is a white 60-mil (1.52 mm) or 90-mil-thick (2.28 mm) non-reinforced EPDM-based elastomeric homogenous roof covering. This roofing membrane may be used for new single-ply roof construction and re-roofing applications. Sure-White 60-mil is available in widths up to 20' (6 m) and lengths of up to 100' (30 m). Sure-White 90-mil is available in widths of 10' (3 m) and lengths of up to 100' (30 m). Sure-White EPDM membrane meets ENERGY STAR®*, LEED® and California Title 24 cool roof standards for initial and aged solar reflectance and thermal emittance.
Features and Benefits
» Carlisle Sure-White EPDM has 25 years of proven performance
» Industry leading resistance to outdoor weathering with 25,200 kJ/m² total radiant exposure without cracking or crazing
» Factory-Applied Tape Seams and Pressure-Sensitive Flashing accessories enhance workmanship quality
» White EPDM helps reduce air conditioning costs in warmer climates
- ENERGY STAR cautions that a heating penalty may outweigh the cooling benefit in central and northern climates
- Reduces carbon footprint by lowering air conditioning costs
» Life Cycle Assessment using EPA’s TRACI model analyzed EPDM, TPO, PVC and Modified-Bitumen
- EPDM had the lowest Global Warming Potential
- EPDM had the lowest Acid Rain impact
- EPDM had the lowest contribution to Smog
» Numerous studies and real world experience confirm that Sure-White EPDM’s 540% elongation and weathering resistance result in superior hail damage resistance; UL 2218 Class 4 rating
» EPDM is the most dimensionally stable heat resistant membrane and stays flexible even in extremely cold conditions , down to -40°F (see Flexibility/Torsion DMA data)
» Extruded manufacturing technology results in seamless 10' wide sheets
» 60-mil and 90-mil membranes available for up to 25- and 30-year warranties and are UL and FM approved
» Zero fungi growth in ASTM G21 test
» Carlisle manufactures all the major components of a typical roofing system including membrane, flashings, tapes, adhesives, sealants, insulations and insulating cover boards
Carlisle’s Factory-Applied Tape Seam Technology
With Carlisle’s patented Factory-Applied Tape (FAT) Seam technology, most of the labor to create seams between membrane panels is completed in a quality-controlled, state-of-the-art environment. This process results in a reliable seam with greater peel and sheer strengths with no entrapped air bubbles. Consistent placement of the FAT also maximizes the splice area and results in a high-quality seam. Carlisle FAT is available on Sure-White membranes up to 20' (6 m) in width, providing the fastest way to complete a seam in today’s roofing market. Shelf life for FAT is 1 year.
Installation
Sure-White membrane is primarily utilized in Design A, Fully Adhered Roofing Systems.
Sure-White Design A: Fully Adhered Roofing System: insulation is mechanically attached or adhered to the roof deck. The substrate and membrane are coated with Carlisle Bonding Adhesive. The membrane is then rolled into place and broomed down. To complete seams between two adjoining membrane panels, apply primer to the splice area in conjunction with Carlisle’s FAT. As an alternative, Carlisle’s hand-applied SecurTAPE may be used.
For cold weather splicing below 40°F (5°C), these steps must be followed:
1. Heat the primed area of the bottom membrane with a hot-air gun as the top sheet with FAT is applied and pressed into place.
2. Prior to rolling the splice area with a 2"-wide steel hand roller, apply heat to the top side of the membrane with a hot-air gun. The heated surface should be hot to the touch. Be careful not to burn or blister the membrane.
Review Carlisle specifications and details for complete installation information.
800-479-6832 | P.O. Box 7000 | Carlisle, PA 17013 | Fax: 717-245-7053 | www.carlislesyntec.com
07.02.15 © 2015 Carlisle.
REPRINT CODE: 605435 - “Sure-White EPDM Roofing Systems Product Data Sheet”
Carlisle, Sure-White and FAT are trademarks of Carlisle. LEED is a registered trademark of the U.S. Green Building Council.
ENERGY STAR is a registered trademark of the U.S. Government. *ENERGY STAR qualification is only valid in the U.S.
Precautions
» Sunglasses that filter our ultraviolet light are strongly recommended as the white surface intensifies sunlight through reflection.
» White surfaces reflect heat and may become slippery due to frost and ice build-up. Exercise extreme caution during cold conditions to prevent falls.
» Use caution when working close to a roof edge when surrounding area is snow covered as roof edge may not be clearly visible.
» Use proper stacking procedures for sufficient stability of materials.
» Exercise caution when walking on wet membrane. Membranes are slippery when wet.
» Membranes with FAT should not be exposed to prolonged jobsite storage temperatures in excess of 90°F (32°C); otherwise, the shelf life of the FAT may be affected.
» When Sure-White with FAT is used, shade the tape end of the rolls until ready to use in warm, sunny weather.
» Shelf life for FAT is 1-year.
Radiative Properties for ENERGY STAR*, Cool Roof Rating Council (CRRC) and LEED
Physical Property Test Method Sure-White
EPDM
ENERGY STAR – Initial solar reflectance
Solar Spectrum Reflectometer
0.76
ENERGY STAR – Solar reflectance after 3 years
Solar Spectrum Reflectometer (after cleaning)
0.64
CRRC – Initial solar reflectance
ASTM C1549 0.76
CRRC – Solar reflectance after 3 years
ASTM C1549 (uncleaned) 0.64
CRRC – Initial thermal emittance
ASTM C1371 0.90
CRRC – Initial thermal emittance after 3 years
ASTM C1371 (uncleaned) 0.87
LEED – Thermal emittance ASTM E408 0.91
SRI –
(Solar Reflectance Index)
ASTM E1980 94
LEED® Information
Pre-consumer Recycled Content 0%
Post-consumer Recycled Content 0%
Manufacturing Location Carlisle, PA
Solar Reflectance Index 94
Membranes
Typical Properties and Characteristics
Physical Property Test Method
SPEC.
(PASS)
Typical
Tolerance on Nominal Thickness, % ASTM D412 ±10 ±10
Weight, lbs/ft² (kg/m²) 60-mil 90-mil
0.37 (1.8)
0.60 (2.9)
Tensile Strength, min, psi (MPa) ASTM D412 1305 (9) 1465 (10.1)
Elongation, Ultimate, min, % ASTM D412 300 540
Tear Strength, min, lbf/in (kN/m) ASTM D624 (Die C)
150 (26.3) 187 (32.7)
Factory Seam Strength, min Modified
ASTM D816
Membrane Rupture
Membrane Rupture
Resistance to Heat Aging* Properties after 28 days @ 240°F (116°C) Tensile Strength, min, psi (MPa) Elongation, Ultimate, min, % Tear Strength, min, lbf/in (kN/m) Linear Dimensional Change, max, %
ASTM D573
ASTM D412
ASTM D412
ASTM D624
ASTM D1204
1205 (8.3) 125 (21.9) ±1.0
1345 (9.3) 185 (32.4)
-0.2
Ozone Resistance* Condition after exposure to 100 pphm Ozone in air for 168 hours @ 104°F (40°C) Specimen is at 50% strain
ASTM D1149 No Cracks No Cracks
Brittleness Temp., max, °F (°C)* ASTM D746 -49 (-45) -67 (-55)
Resistance to Water Absorption* After 7 days immersion @ 158°F (70°C) Change in mass, max, %
ASTM D471 +8, -2 +3.3
Water Vapor Permeance* Max, perms
ASTM E 96
(Proc. B or BW)
0.10 0.02
Flexibility/Torsion DMA ASTM D5279-08 N/A 55 MPa @ -40°F
Fungi Resistance ASTM G21 N/A 0 (No Growth)
Resistance to Outdoor (Ultraviolet) Weathering* Xenon-Arc, total radiant exposure at 0.70 W/m² irradiance, 80°C black panel temperature
ASTM G155 No Cracks No Crazing 7,560 kJ/m² 3,000 hrs
No Cracks No Crazing 25,200 kJ/m² 10,000 hrs
At 0.35 W/m² irradiance, 80°C black panel temperature
6,000 hrs 20,000 hrs
*Not a Quality Control Test due to the time required for the test or the complexity of the test.
However, all tests are run on a statistical basis to ensure overall long-term performance of the sheeting.
Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not reflect the specification range for any particular property of this product.
Note: Sure-White non-reinforced EPDM membrane meets or exceeds the minimum requirements set forth by ASTM D4637 for Type I non-reinforced EPDM single-ply roofing membranes.
* The ENERGY STAR program recommends using the Roof Savings Calculator (rsc.ornl.gov) to determine if a white reflective roof will save or cost you money compared to a dark-colored roof depending on geographic climate conditions, building location, and other variables.
800-479-6832 | P.O. Box 7000 | Carlisle, PA 17013 | Fax: 717-245-7053 | www.carlislesyntec.com
Overview
DensDeck Prime Roof Board’s patented design features a gypsum core with embedded glass mat facers on the top and bottom of the board.
DensDeck Prime can be used in a variety of commercial roof systems and provides an excellent thermal barrier as well as exceptional fi re, moisture, and wind uplift resistance properties.
DensDeck Prime is typically used as a cover board over insulation in fully adhered EPDM, TPO, and PVC applications. It is compatible with solvent-based bonding adhesives. For applications in which Carlisle’s FAST™, or Flexible FAST Adhesive is used to attach insulation and a vapor barrier is specifi ed, DensDeck Prime can be used as a base layer for Carlisle’s VapAir™ Seal 725TR Air and Vapor Barrier (in conjunction with CCW 702-LV or CAV-GRIP™ Primer). DensDeck Prime is also compatible with hot asphalt and can be used as a membrane underlayment in hot mopped roofi ng systems or as a parapet wall substrate in all systems.
Features and Benefi ts
» UL code ratings available for high slopes and wood decks
» FM Approved
» Improves resistance to foot traffi c and hail damage
» Excellent wind uplift ratings
» Resistant to deterioration, warping, and jobsite damage
Installation
DensDeck Prime may be secured with FAST Adhesive, fastened in accordance with an approved fastening pattern, or mopped with Type III or IV asphalt.
Edge joints should be located on and parallel to deck ribs. End joints of adjacent lengths should be staggered.
1. This material shall be installed with ends and edges butted tightly.
2. When installed over combustible wood decks or insulations, all joints should be staggered.
3. In accordance with approved shop drawings, FM Approved fasteners shall be installed with plates through the roof board, fl ush with the surface.
4. When attaching VapAir Seal 725TR, use DensDeck Prime in conjunction with CCW-702, 702-LV, or CAV-GRIP Primer.
Review Carlisle specifi cations and details for complete installation
DensDeck® Prime Roof Board
09.17.15 © 2015 Carlisle.
REPRINT CODE: 601960 - “DensDeck Prime Roof Board Product Data Sheet”
Carlisle, FAST, VapAir and CAV-GRIP are trademarks of Carlisle. DensDeck is a registered trademark of Georgia-Pacifi c Gypsum LLC.
Typical Properties and Characteristics
Properties ¼" (6.4 mm) ½" (12.7 mm) 5⁄8" (15.9 mm)
Thickness, nominal ¼" (6.4 mm) ± 1⁄16" (1.6 mm) 1/2" (12.7 mm) ± 1⁄32" (.8 mm) 5/8" (15.9 mm) ± 1⁄32" (.8 mm)
Width, standard 4' (1219 mm) ± 1⁄8" (3 mm) 4' (1219 mm) ± 1⁄8" (3 mm) 4' (1219 mm) ± 1⁄8" (3 mm)
Length, standard 8' (2438 mm) ± ¼" (6.4 mm) 8' (2438 mm) ± ¼" (6.4 mm) 8' (2438 mm) ± ¼" (6.4 mm)
Weight, nominal, lbs./sq. ft. (Kg/m²)7 1.2 (5.9) 2.0 (9.8) 2.5 (12.2)
Surfacing Fiberglass mat Fiberglass mat Fiberglass mat
Flexural Strength1, parallel, lbf. min. (N) ≥40 (178) ≥80 (356) ≥100 (444)
Flute Spanability 2 2-5⁄8" (67 mm) 5" (127 mm) 8" (203 mm)
Permeance3, Perms (ng/Pa• S• m²) >30 (>1710) >23 (>1300) >17 (>970)
R Value4, ft²• °F• hr/BTU (m²• K/ W) 0.28 0.56 0.67
Linear Variation with Change in Temp., in/in °F (mm/mm/C°) 8.5 x 10-6 (15.3 x 10-6) 8.5 x 10-6 (15.3 x 10-6) 8.5 x 10-6 (15.3 x 10-6)
Linear Variation with Change in Moisture 6.25 x 10-6 6.25 x 10-6 6.25 x 10-6
Water Absorption5, % max <10 <10 <10
Compressive Strength6, psi nominal1 900 900 900
Surface Water Absorption, grams, nominal < 2.0 < 2.0 < 2.0
Flame Spread, Smoke Developed (ASTM E84) 0/0 0/0 0/0
Bending Radius 4' (1219 mm) 6' (1829 mm) 8' (2438 mm)
1 Tested in accordance with ASTM C473 method B.
2 Tested in accordance with ASTM E661.
3 Tested in accordance with ASTM E96 (dry cup method).
4 Tested in accordance with ASTM C518 (heat fl ow meter).
5 Tested in accordance with ASTM C1177.
6 Tested in accordance with ASTM C473.
7 Represents approximate weight for design and shipping purposes. Actual weight may vary based on manufacturing location and other factors.
DensDeck Prime Roof Board
Precautions
» Panels must be kept dry before, during and after installation. Apply only as much roof board as can be covered by roof membrane in the same day.
» When applying solvent-based adhesives or primers, allow suffi cient time for the solvents to fl ash off.
» ¼" DensDeck Prime is not recommended for vertical parapet applications.
» In ballasted roofi ng systems, DensDeck Prime is not an acceptable membrane underlayment.
Ratings and Certifi cations
» Manufactured to conform to ASTM C-1177
» Tested in accordance with ASTM E-84 or CAN/ULC-S102
» Non-combustible when tested in accordance with ASTM E-136
» UL Classifi ed when tested in accordance with ASTM E-119
LEED® Information
Manufacturing Location1
Total Recycled Content2
Pre-Consumer Recycled Content22
Post-Consumer Recycled Content2
Acme, TX 0% 0% 0%
Antioch, CA 0% 0% 0%
Caledonia, ON 50% 50% 0%
Ft. Dodge, IA 0% 0% 0%
Lovell, WY 0% 0% 0%
Newington, NH 30% 30% 0%
Savannah, GA 0% 0% 0%
Tacoma, WA 14% 14% 0%
Wheatfi eld, IN 94% 94% 0%
1 Manufacturing locations subject to change. Please visit www.gpgypsum.com and click on Sustainability.
2 Minimum value as of October 1, 2009 for product recycled content +/– 1.0%.
3 Based on ICC Evaluation Service Verifi cation of Attributes Report for Dens® brand products issued August 1, 2009. www.saveprogram.icc-es.org
800-479-6832 | P.O. Box 7000 | Carlisle, PA 17013 | Fax: 717-245-7053 | www.carlislesyntec.com
Overview
InsulBase is a rigid-roof insulation panel composed of a closed-cell polyisocyanurate foam core bonded on each side to fi ber-reinforced paper facers.
Features and Benefi ts
» InsulBase polyiso insulation provides the highest R-value per inch of commercially available insulation products
» Environmentally friendly construction with 0% ozone-depleting components and CFC free
» Approved for direct application to steel decks
Panel Characteristics
» Available in 4' x 4' (1220 mm x 1220 mm) and 4' x 8' (1220 mm x 2440
mm) panels in thickness of ½" (13 mm) to 4.5" (115 mm)
» Available in two grades of compressive strengths per ASTM C1289, Type II, Class 1, Grade 2 (20 psi), Grade 3 (25 psi)
Applications
» Constructions requiring FM Class 1 and UL Class A ratings
» Single-Ply Roof Systems (Ballasted, Mechanically Attached, Fully Adhered)
Installation
Ballasted Single-Ply Systems Each InsulBase panel is loosely laid on the roof deck. Butt edges and stagger joints of adjacent panels. Install the roof membrane according to Carlisle’s specifi cations.
Mechanically Attached Single-Ply Systems InsulBase panels must be secured to the roof deck with fasteners and plates (appropriate to the deck type). Butt edges and stagger joints of adjacent panels. Install the roof membrane according to Carlisle’s specifi cations.
Fully Adhered Single-Ply Systems InsulBase panels must be secured to the roof deck with fasteners and plates (appropriate to deck type). Butt edges and stagger joints of adjacent panels. Install the roof membrane according to Carlisle’s specifi cations.
InsulBase 4' x 8' panels can be secured to the roof deck with Carlisle’s FAST® Adhesive, either full coverage or bead spacing.
InsulBase 4' x 4' panels may be adhered to prepared concrete deck with a full mopping of Type III or IV asphalt.
Review Carlisle specifi cations and details for complete installation information.
InsulBase Polyiso Thermal Values
Thickness (inches)
Thickness
(MM)
LTTR
R-value**
Flute Spanability
0.50 13 2.8 2 5⁄8”
1.00 25 5.7 2 5⁄8"
1.50 38 8.6 4 3⁄8"
1.75 44 10.0 4 3⁄8"
1.80 46 10.3 4 3⁄8"
2.00 51 11.4 4 3⁄8"
2.50 64 14.4 4 3⁄8"
2.60 66 15.0 4 3⁄8"
3.00 76 17.4 4 3⁄8"
3.50 89 20.5 4 3⁄8"
3.80 97 22.3 4 3⁄8"
4.00 102 23.6 4 3⁄8"
4.30 109 25.5 4 3⁄8"
4.50 114 26.8 4 3⁄8"
** Long-Term Thermal Resistance Values are based on ASTM C1289 effective January 1, 2014, predicting product R-value after fi ve years, which is equivalent to a time-weighted thermal design R-value for 15 years.
2 LAYERS
800-479-6832 | P.O. Box 7000 | Carlisle, PA 17013 | Fax: 717-245-7053 | www.carlislesyntec.com
09.15.17 © 2017 Carlisle.
REPRINT CODE: 600491 - “InsulBase Polyiso Product Data Sheet”
Carlisle, SecurShield, InsulBase and FAST are trademarks of Carlisle.
InsulBase Codes and Compliances
» ASTM C1289, Type II, Class 1, Grade 2 (20 psi), Grade 3 (25 psi)
» International Building Code (IBC) Section 2603
Underwriters Laboratories, Inc.
» Component of Class A Roof Systems (UL 790)
» Hourly Rated P series roof assemblies (UL 263) P 225, 230, 259, 302, 303, 508, 510, 514, 519, 701, 710, 713, 717, 718, 719, 720, 722, 723, 727, 728, 729, 730, 732, 734, 735, 739, 741, 742, 743, 819, 824, 827, 828
» Insulated metal deck assemblies - (UL 1256) nos. 120, 123, 292
» InsulBase classifi ed by ULC
» R18846
Factory Mutual Research
» FM Class 1 approval for steel roof-deck constructions, (FM 4450)
» FM 4470
(Subject to the conditions of approval described in Roofnav.com)
» FLORIDA BUILDING CODE APPROVAL FL#1296
» MIAMI-DADE COUNTY, FLORIDA NOA NO: 04-1018.01
Precautions
Insulation must be protected from open fl ame and kept dry at all times.
Install only as much insulation as can be covered the same day by completed roof-covering material. Protect installed product from excessive foot traffi c. Carlisle will not be responsible for specifi c building and roof design by others, for defi ciencies in construction or workmanship, for dangerous conditions on the job site or for improper storage and handling.
Technical specifi cations shown in this literature are intended to be used as general guidelines only and are subject to change without notice. Call Carlisle for more specifi c details, or refer to PIMA Technical Bulletin No.
109: Storage & Handling Recommendations for Polyiso Roof Insulation.
Typical Properties and Characteristics
(ASTM C1289)
Physical Property Test Method Value
Compressive Strength ASTM D1621 20 psi* minimum (138 kPa, Grade 2)
Dimensional Stability ASTM D2126 2% linear change (7 days)
Moisture Vapor Permeance ASTM E96 <1 perm (57.5 ng/(Pa•s•m²))
Water Absorption C1763 <1% volume
Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not refl ect the specifi cation range for any particular property of this product.
* Polyiso Foam Core only
Foamed plastic as roof deck construction material with resistance to an internal fi re exposure only for use in construction no.(s) 120 and 123. See UL Directory of Products Certifi ed for Canada and UL Roofi ng Materials and Systems Directory. 99DL.
800-479-6832 | P.O. Box 7000 | Carlisle, PA 17013 | Fax: 717-245-7053 | www.carlislesyntec.com
Overview
InsulBase Tapered is a sloped rigid roof insulation panel composed of a closed cell polyisocyanurate foam core bonded during the manufacturing process to fi ber reinforced paper facers. Tapered systems are designed to promote positive drainage and prevent ponding water. Contact Carlisle’s Tapered Systems Group for design assistance.
Features and Benefi ts
» InsulBase tapered polyiso insulation provides the highest R-value per inch of commercially available insulation products.
» Environmentally friendly construction with 0% ozone depleting components and CFC free.
» Approved for direct application to steel decks.
Panel Characteristics
» Available in 4' x 4' (1220 mm x 1220 mm) in thickness of ½" (12 mm) minimum to 4.5" (115 mm) maximum in a single layer
» Available slopes are 1⁄16" (2 mm), 1⁄8" (3 mm), 3⁄16" (5 mm), ¼" (6 mm), 3⁄8" (10 mm) and ½" (12 mm) per foot
» Available in two grades of compressive strengths per ASTM C1289, Type II, Class 1, Grade 2 (20 psi), Grade 3 (25 psi)
Applications
» Constructions requiring FM Class 1 and UL Class A ratings
» Single-Ply Roof Systems (Ballasted, Mechanically Attached, Fully Adhered)
Installation
Ballasted Single-Ply Systems
Each InsulBase Tapered panel is loosely laid on the roof deck. Butt edges and stagger joints of adjacent panels. Install the roof membrane according to Carlisle’s specifi cations.
Standard Panel Profi les ¼" Slope
1.5" 3.5" 7.5"5.5"0.5" 2.5" 4.5" 6.5" 8.5"
X
X
X
X
Y
Y
Y
Y
1/4" Slope
Reference Fill Below
2.0" ISO
2.0" ISO
2.0" ISO
6.5" 10.5"2.5"0.5" 4.5" 8.5" 12.5"
2.0" ISO
2.0" ISO
2.0" ISO
2.0" ISO
2.0"
Q
Q Q1
Q
Q Q
Q
Q
Q2 Q3 Q4 Q5
1/2" Slope
Reference Fill Below
½" Slope
0.5" 1.0" 2.0" 3.0" 4.0" 5.0" 6.0" 8.0"7.0"1.5" 2.5" 3.5" 4.5" 5.5" 6.5" 7.5" 8.5"
A B C 2.0" ISO
2.0" ISO
2.0" ISO
1/8" Slope
Reference Fill Below
1⁄8" Slope
A B C A B C
A B C
Extended Panel Profi les
AA
AA
0.5" 1.0" 2.0" 3.0" 4.0" 5.0" 6.0" 8.0"7.0"1.5" 2.5" 3.5" 4.5" 5.5" 6.5" 7.5" 8.5"
AA
AA1
A
A
A
A1
B
B
B
B1
C
C
C
C1
4.0" ISO
D
D
D
D1
E
E
E
E1
F
F
F
F1
FF
FF
FF
FF1
1/8" Slope
Reference Fill Below
1⁄8" Slope
1.5" 3.5" 7.5"5.5"0.5" 2.5" 4.5" 6.5" 8.5"
X Y Z ZZ
4.0" ISO
X
X
X1
Y
Y
Y1
Z
Z
Z1
ZZ
ZZ
ZZ1
1/4" Slope
Reference Fill Below
¼" Slope 6.5"2.5"0.5" 4.5" 8.5"
4.0" ISO
Q
Q
Q
Q1
QQ1
1/2" Slope
Fill Below
½" Slope
AA
AA
AA
AA
800-479-6832 | P.O. Box 7000 | Carlisle, PA 17013 | Fax: 717-245-7053 | www.carlislesyntec.com
12.20.16 © 2013 Carlisle.
REPRINT CODE: 603256 - “InsulBase Tapered Polyiso Product Data Sheet”
Carlisle, InsulBase, StormBase, SecurShield and FAST are trademarks of Carlisle.
Mechanically Attached & Fully Adhered Single-Ply Systems
Each InsulBase Tapered panel must be secured to the roof deck with fasteners and plates (appropriate to deck type). Butt edges and stagger joints of adjacent panels.Install the roof membrane according to Carlisle’s specifi cations.
For fully adhered single-ply, InsulBase Tapered 4' x 8' panels can be secured to the roof deck with Carlisle’s FAST® Adhesive, either full coverage or bead spacing of no less than 6" on center.
Review Carlisle specifi cations and details for complete installation information.
InsulBase Tapered Codes and Compliances
» ASTM C1289, Type II, Class 1, Grade 2 (20 psi), Grade 3 (25 psi)
» International Building Code (IBC) Section 2603
NOTE: Please be aware the Federal Specifi cation HH-I-1972/GEN has been replaced.
Underwriters Laboratories, Inc.
» Component of Class A Roof Systems (UL 790)
» Hourly Rated P series roof assemblies (UL 263) P 225, 230, 259, 302, 303, 508, 510, 514, 519, 701, 710, 713, 717, 718, 719, 720, 722, 723, 727, 728, 729, 730, 732, 734, 735, 739, 741, 742, 743, 819, 824, 827, » Insulated metal deck assemblies - (UL 1256) nos. 120, 123, 292
» InsulBase Tapered classifi ed by ULC
Factory Mutual Research
» FM Class 1 approval for steel roof-deck constructions, (FM 4450)
» FM 4470
(Subject to the conditions of approval described in Roofnav.com)
» FLORIDA BUILDING CODE APPROVAL FL#1296
» MIAMI-DADE COUNTY, FLORIDA NOA NO: 04-1018.01
Precautions
Insulation must be protected from open fl ame and kept dry at all times.
Install only as much insulation as can be covered the same day by completed roof covering material. Protect installed product from excessive foot traffi c. Carlisle will not be responsible for specifi c building and roof design by others, for defi ciencies in construction or workmanship, for dangerous conditions on the job site or for improper storage and handling.
Technical specifi cations shown in this literature are intended to be used as general guidelines only and are subject to change without notice. Call Carlisle for more specifi c details, or refer to PIMA Technical Bulletin No.
109: Storage & Handling Recommendations for Polyiso Roof Insulation.
Typical Properties and Characteristics
Physical Property Test Method Value
Compressive Strength ASTM D1621
ASTM 1289
20 psi* minimum (138 kPa, Grade 2)
Dimensional Stability ASTM D2126 2% linear change (7 days)
Moisture Vapor Transmission ASTM E96 12.10 <1 perm (57.5 ng/(Pa•s•m²))
Water Absorption ASTM C209 <1% volume
Service Temperature -100°F to 250°F (-73°C to 122°C)
Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not refl ect the specifi cation range for any particular property of this product.
Foamed plastic as roof deck construction material with resistance to an internal fi re exposure only for use in construction no.(s) 120 and 123. See UL Directory of Products Certifi ed for Canada and UL Roofi ng Materials and Systems Directory. 99DL.
Other Polyiso Products by Carlisle
» Flat and Tapered SecurShield™ – Polyiso bonded to coated glass facers
» Flat Polyiso bonded to fi ber-reinforced paper facers
» HP-F – Polyiso bonded to foil
» StormBase® – Polyiso bonded to Oriented Strand Board
» SecurShield HD – ½" Polyiso coverboard, 100 PSI
» SecurShield HD Composite – Polyiso bonded on-line to ½" SecurShield HD Coverboard
» SecurShield HD Plus – ½" Polyiso coverboard, 100 PSI – FM 1-90 with reduced fastening
» SecurShield CD – 1" Class A Polyiso on a combustible deck
800-479-6832 | P.O. Box 7000 | Carlisle, PA 17013 | Fax: 717-245-7053 | www.carlislesyntec.com
Pressure-Sensitive Elastoform Flashing®
Overview
Carlisle’s Sure-White EPDM Pressure-Sensitive (PS) Elastoform Flashing is a nominal 60-mil-thick (1.5 mm)-thick, uncured EPDM membrane, laminated to a nominal 30-mil-thick (0.75 mm), fully cured PS adhesive.
This product is available in 6" x 100', 9" x 50', 12" x 50' rolls and is easily malleable and highly adaptable to irregular shapes and surfaces.
PS Elastoform Flashing is self curing and can be used to fl ash pipes and scuppers, as well as other rooftop structures and penetrations. The clear poly release liner on the 12"-wide product is pre-slit down the center, allowing the applicator to partially remove the liner for ease of installation.
Features and Benefi ts
» Available in 6" x 100', 9" x 50' and 12" x 50' rolls
» Adaptable to irregular shapes and surfaces
» Self-curing membrane
» Labor and cost savings in fi eld applications
» Approved for use on EPDM and TPO membranes
Installation
1. The entire surface where the PS Elastoform Flashing will be applied must be clean. The adhesive on the back of the PS Elastoform Flashing will not adhere to dusted or dirty surfaces. Any residual contamination will be detrimental to the bond strength of the adhesive.
2. Remove all foreign material.
a. Remove excess mica dust by brooming or wiping with a clean, dry rag or Carlisle HP Splice Wipe.
b. The use of Weathered Membrane Cleaner may be necessary.
This process is essential on membrane that has been exposed for a number of weeks.
Note: Permeation-resistant gloves (that meet ANSI/ISEA 105- 2005) are required for hand protection when cleaners or primers are being used.
c. Allow the membrane to dry thoroughly before proceeding.
3. Apply HP-250,TPO Primer, or Low-VOC Primer per instructions on respective product data sheets. Membrane type determines which primer to use. HP-250 Primer is used with EPDM membranes. TPO Primer is used with TPO membranes. Low-VOC Primer can be used with either TPO or EPDM membranes. Review Carlisle specifi cations and details for complete installation information.
Note: The use of excessive amounts of primer will not signifi cantly enhance the adhesion of the PS Elastoform Flashing to the EPDM membrane. Use only the amount necessary to obtain 100% coverage of the area where the PS Elastoform Flashing will be applied.
4. Allow the primer to fl ash-off until it does not transfer to a dry fi nger touch yet remains tacky. Install the pressure-sensitive product immediately after the primer has fl ashed-off to promote adhesion and avoid contamination.
5. Position the fl ashing over the area to be covered and press down the exposed tape adhesive using fi rm, even hand pressure across the entire area. Install the elongated diamond pattern parallel to the deck when fl ashing corners or vertical pipe wraps.
6. Immediately roll the PS Elastoform Flashing with a 2"-wide (50 mm) roller, using positive pressure. Roll across the fl ashing edge, not parallel to it. Install the elongated diamond pattern parallel to the deck when fl ashing corners or vertical pipe wraps.
7. To achieve proper adhesion of the PS Elastoform Flashing when jobsite temperatures fall below 40°F (4°C), heat the primed area of the membrane with a hot-air gun as the fl ashing is applied and pressed into place.
8. Apply Lap Sealant (EPDM) or Universal Single-Ply Sealant (TPO) to the outside edge of the fl ashing.
9. PS Elastoform Flashing is used to fl ash many different roofi ng system structures and penetrations. The specifi c method of applying the fl ashing for each individual situation is different. The appropriate Carlisle specifi cation and/or detail must be consulted prior to application.
Review Carlisle specifi cations and details for complete installation
12.17.14 © 2014 Carlisle.
REPRINT CODE: 603397 - “Sure-White EPDM Pressure-Sensitive Elastoform Flashing Product Data Sheet”
Carlisle, Sure-White, Pre-Kleened and Elastoform Flashing are trademarks of Carlisle.
LEED is a registered trademark of the U.S. Green Building Council.
Precautions
» Avoid prolonged contact with skin. In case of contact with skin, thoroughly wash affected area with soap and water.
» Prolonged jobsite storage temperatures in excess of 90°F (32°C) will shorten product shelf life.
» In warm, sunny weather, keep PS Elastoform Flashing rolls in their box and in a shaded area until ready to use.
» Storage and use of PS Elastoform Flashing at temperatures below 40°F (4°C) will result in a loss of adhesive tack and, in extreme cases, will result in no bond to the substrate. Overnight storage must be available to keep the temperature of the PS Elastoform Flashing at a minimum of 60°F (15°C). Hot boxes for jobsite storage must be provided to maintain a minimum product temperature of 40°F (4°C).
» PS Elastoform Flashing must be stored in a dry area. It is recommended to store the fl ashing below 80°F (27°C) to ensure maximum formability and shelf life.
» Due to solvent fl ash-off, condensation may form on applied primer when the ambient temperature is near the dew point. If condensation develops, the application of primer and PS Elastoform Flashing must be discontinued as proper adhesion will not be achieved. Allow the surface to dry and apply primer to the previously coated surface and apply PS Elastoform Flashing when conditions allow.
» Do not allow waste products (petroleum, grease, oil, solvents, vegetable or mineral oils, animal fats, etc.) or direct steam venting to come in contact with the PS Elastoform Flashing.
» A heat gun is required when forming PS Elastoform Flashing in colder temperatures as outlined in the specifi cation.
» KEEP OUT OF THE REACH OF CHILDREN.
Typical Properties and Characteristics
Color White
Base Membrane Adhesive
EPDM
Synthetic Rubber
Solids 100%
Ozone Resistance Condition after exposure to 100 pphm Ozone in air for 168 hrs. @ 104°F (40°C) (Specimen under 50% strain)
No cracks
Brittleness Temp -49°F (-45°C)
Nominal Thickness 88 mil (2.24 mm)
Nominal Width 6" (152 mm), 9" (230 mm), 12" (305 mm), 63⁄16" (157 mm), 93⁄16" (235 mm), 123⁄16" (310 mm)
Net Weight Per Roll 6"= 30 lbs (13.6 kg) 9"= 24 lbs (10.9 kg) 12"= 32 lbs (14.5 kg)
Packaging 6"= 2 rolls/carton, 100' (30.5 m) 9"= 1 roll/carton, 50' (15.2 m) 12"= 1 roll/carton, 50' (15.2 m)
Shelf Life 6 months when stored between 60°F–80°F (15°C–26°C)
Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not refl ect the specifi cation range for any particular property of this product.
Pressure-Sensitive Elastoform Flashing
LEED® Information
Pre-consumer Recycled Content 2%
Post-consumer Recycled Content 0%
Manufacturing Location Greenville, IL
Solar Refl ectance Index (SRI) N/A
Let Carlisle simplify your next Sure-White EPDM installation with their Pressure-Sensitive Curb Flashing. The most effi cient means to fl ash a curb as membrane comes pre-cut 20" wide with 6" SecurTAPE™ already applied. Production time on projects with numerous curbs or wall fl ashings can be substantially reduced with this labor saving accessory.
Features and Benefi ts
• Available in 20" x 50' rolls of cured 60-mil EPDM fl ashing
• Pre-cut 20" wide with 6" SecurTAPE already applied
• Provides up to 70% labor savings for fl ashing curbs and walls
• Cleaner appearance and stronger seams
Installation*
1. Attach deck membrane at the curb according to specifi c Carlisle system details.
2. Cut a piece of PS Curb Flashing equal in length to the perimeter of the curb plus 3" minimum (i.e. a 2' x 2' curb would require a 8'– 3" length of PS Curb Flashing).
3. For curbs where the deck membrane is fastened on the vertical, cut the width of the PS Curb Flashing to match the height of the curb plus 6" for the splice and 2" to go over the top of the curb. (Width = curb height + 8".) For curbs where the deck membrane is fastened on the horizontal, cut the width of the PS Curb Flashing to allow a minimum of 3" of splice beyond the 2" fastening plates and 2" to go over top of the curb. (Width = curb height + 8".)
4. Place the PS Curb Flashing on a fl at surface with the tape side up and the release liner intact.
5. Apply Carlisle Bonding Adhesive to the curb and to the PS Curb Flashing.
6. While the bonding adhesive is drying, apply EPDM Primer to the splice area on the deck membrane.
7. After the bonding adhesive and primer have dried properly, bond the PS Curb Flashing to the curb. Wrap the entire curb, leaving the area containing the tape adhesive folded upwards with release liner still in place. Care should be taken not to stretch the PS Curb Flashing.
8. To complete the splice between the PS Curb Flashing and the deck membrane, cut the PS Curb Flashing at each corner of the curb, allowing the PS Curb Flashing to fall in place. Round all cut corners. Press the PS Curb Flashing into the angle change as tightly as possible.
9. With the tape adhesive laying fl at on the primed surface, remove the release liner by pulling it out from beneath the PS Curb Flashing while simultaneously pressing the tape onto the primed surface using fi rm even hand pressure across the splice towards the splice edge. Immediately roll the splice with a 2"-wide (50 mm) roller, using positive pressure.
10. Broom the mated PS Curb Flashing over the curb to ensure proper mating of the bonding adhesive.
11. Make the vertical splice in the PS Curb Flashing as per Carlisle U-2A details.
12. Flash the corners of the curb as per Carlisle U-15 details.
* REVIEW CURRENT CARLISLE SPECIFICATIONS AND DETAILS
FOR SPECIFIC INSTALLATION REQUIREMENTS.
Product Data
SURE-WHITE® PRESSURE-SENSITIVE
CURB FLASHING
800-479-6832 • P.O. Box 7000 • Carlisle, PA 17013 • Fax: 717-245-7053 • www.carlislesyntec.com
Precautions
1. Avoid prolonged contact with skin. In case,of contact with skin, thoroughly wash affected area with soap and water.
2. Carlisle Bonding Adhesive and EPDM Primer must be used when installing PS Curb Flashing.
3. PS Curb Flashing must be stored in a dry area. In warm, sunny weather, keep PS Curb Flashing in the box or in a shaded area until ready to use.
4. Due to solvent fl ash-off, condensation may form on freshly applied Primer when the ambient temperature is near the dew point. If condensation develops, the application of Primer and installation of PS Curb Flashing must be discontinued, as proper adhesion will not be achieved. Allow the primed surface to dry and apply a thin freshener coat of Primer to the previously coated surface when conditions allow.
5. Jobsite storage temperatures in excess of 90°F (32°C) may affect product shelf life. Prolonged jobsite exposure to temperatures below 40°F (4°C) will cause the adhesive to lose tack and in extreme cases not bond to the EPDM membrane. If this situation is encountered, move PS Curb Flashing to a warm area and allow it to return to a minimum of 60°F (15°C).
6. In order to achieve proper adhesion to the deck membrane when installing PS Curb Flashing at temperatures below 40°F (5°C), heat the primed area of the deck membrane with a hot-air gun as the tape adhesive is applied and pressed into place.
7. Do not allow waste products (petroleum, grease, oil, solvents, vegetable or mineral oil, animal fats, etc.) or direct steam venting to come in contact with the PS Curb Flashing.
8. KEEP OUT OF THE REACH OF CHILDREN.
Product Data
SURE-WHITE PRESSURE-SENSITIVE
CURB FLASHING
Sure-White Pressure-Sensitive Curb Flashing Typical Properties and Characteristics** Base Membrane -EPDM
Adhesive-Synthetic Polymers Thickness Membrane - 60-mil (1.52) mm)
Size 20" x 50' (508 mm x 15.2 m)
Packaging 50 lf /carton (15.2 m) - 1 roll/carton
Weight/Carton 30 lbs (13.6 Kg)
Shelf Life 1 year
** Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product.
This data and information is intended as a guide and does not refl ect the specifi cation or specifi cation range for any particular property of this product.
800-479-6832 • P.O. Box 7000 • Carlisle, PA 17013 • Fax: 717-245-7053 • www.carlislesyntec.com Carlisle, Sure-White and SecurTAPE are trademarks of Carlisle.
REPRINT CODE: 603396 – “Sure-White Pressure-Sensitive Curb Flashing Product Data Sheet” – 080812 © 2012 Carlisle.
1. Review the applicable Material Safety Data Sheet for complete safety information prior to use.
2. Splicing Cements are EXTREMELY FLAMMABLE. They contain petroleum distillates that are dangerous fi re and explosion hazards when exposed to heat, fl ame or sparks. Store and use away from all sources of heat, fl ame or sparks. Do not smoke while applying. Do not use in a confi ned or unventilated area.
Vapors are heavier than air and may travel along ground to a distant ignition source and fl ash back. A red caution label is required when shipping.
3. During application, efforts must be made to prevent fumes from entering the building via air ventilation ducts. Do not place open containers or mix adhesive near fresh-air intake units.
When possible, shut down or seal off the closest units. Avoid breathing vapors. Keep container closed when not in use. Use with adequate ventilation. If inhaled, remove to fresh air. If not breathing, perform artifi cial respiration. If breathing is diffi cult, give oxygen. Call a physician immediately.
4. If swallowed, DO NOT INDUCE VOMITING. Call a physician immediately.
5. Avoid contact with eyes. Safety glasses or goggles are recommended. If splashed in eyes, immediately fl ush eyes with plenty of water for at least 15 minutes. Contact a physician immediately.
6. Avoid contact with skin. Wash hands thoroughly after handling.
In case of contact with skin, thoroughly wash affected area with soap and water.
Note: Permeation-resistant gloves (that meet ANSI/ISEA 105-2005) are recommended to be worn when using this product to protect hands from irritating ingredients.
7. Do not thin Splicing Cements. Thinning will affect performance.
8. Jobsite storage temperatures in excess of 90°F (32°C) may affect product shelf life. This will eventually thicken the cement and cause the product to become diffi cult or even impossible to use. When storage temperatures become elevated, Splicing Cements should be stored in a controlled environment. Should Splicing Cement be stored at temperatures below 60ºF (15°C), restore to room temperature prior to use. Stir cement occasionally while using.
9. Opened containers of Splicing Cement should be used within 48 hours. Cement will begin to thicken after this time, making it diffi cult and eventually impossible to control adhesive thickness.
10. KEEP OUT OF THE REACH OF CHILDREN.
Sure-Seal and Sure-White Splicing Cements Typical Properties and Characteristics Base Synthetic Rubber
Color Sure-Seal – black Sure-White – white
Solids Sure-Seal – 30% Sure-White – 28%
Flash Point 8°F (-13°C) Closed Cup
Average Brookfi eld Viscosity Sure-Seal – 3800 Centipoise Sure-White – 3500 Centipoise
Average Net Weight Sure-Seal – 7.4 lbs./gal. (0.89 Kg/l) Sure-White – 7.5 lbs./gal. (0.9 Kg/l)
Packaging Sure-Seal – 6 1-gal. cans Sure-White – 6 1-gal. cans
Shelf Life Sure-Seal – 12 months Sure-White – 9 months
Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not refl ect the specifi cation or specifi cation range for any particular property of this product.
Product Data
SURE-SEAL/SURE-WHITE
SPLICING CEMENTS
800-479-6832 • P.O. Box 7000 • Carlisle, PA 17013 • Fax: 717-245-7053 • www.carlislesyntec.com Carlisle, Sure-Seal and Sure-White are trademarks of Carlisle. LEED is a registered trademark of the U.S. Green Building Council.
REPRINT CODE: 605056 - “Sure-Seal/Sure-White Splicing Cement Product Data Sheet” - 10.23.12 © 2012 Carlisle.
LEED® Information Pre-consumer Recycled Content 0%
Post-consumer Recycled Content 0%
VOC Content Sure-Seal – 605 grams/liter Sure-White – 637 grams/liter
Manufacturing Location Carlisle, PA
Fastening and Termination Bars
Typical Properties and Characteristics
Material Engineered Polymer
Dimensions 1" (25 mm) wide x 250' (76 m) long
Packaging 250 lf (76 m) per carton
Weight 10 lbs. (5 kg) carton
Typical Properties and Characteristics
Material Galvalume Coated Metal
Dimensions 1" (102 mm) wide x 10' (3 m) long
Packaging 50 pcs; 500 lf (152 m) per carton
Weight 85 lbs. (39 kg) carton
Polymer Fastening Bar
The Polymer Fastening Bar is an engineered polymer bar that’s used to mechanically fasten EPDM membranes per Carlisle Specifi cations. The bar is packaged in a 1" x 250' coil that has pre-punched holes every 3" on center. The bar can be easily cut to any desired length. When installing, make sure that all corners of cut bar are rounded.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .