inches cubic yards psi @ gallons
¯F lbf/cu.ft. ¯F inches in.x in. sq. in.
lbf lbf per sq.in.
2400 East Huntington Drive Flagstaff, AZ 86004
(928) 774-8700
10-09-17 Client BRISTON CONSTRUCTION 2547JP163
521 SOUTH 48TH STREET, # 106 27/70827 189
TEMPE, AZ 85281 WILEY HERMAN 09-28-17
WT/KEN MALANCA 09-28-17
WT/ROY KEITH 09-29-17
BRISTON CONSTRUCTION
NEW LAB PHARMACY BUILDING 164 NORTHERN ARIZONA VA HEALT
VA PRESCOTT
ELEVATOR PIT WALL & COLUMNS H.3 H.25
CEMEX
2674-44322309 1332869
10.8 4000 28 0 40 65 08:50
ASTM C172
ASTM C1064 67
2.0ASTM C231 ASTM C143 6 1/4
ASTM C31
ASTM C31 & C39
WT/ROY KEITH
(SIGNED COPY ON FILE)
5 4.00 8 12.57
189A 10-02-17 4 44510 3540 COLUMNAR SO
189B 10-05-17 7 47490 3780 CONE/VERTICAL RK
189C 10-26-17 28
189D 10-26-17 28
189E HOLD
BRISTON CONSTRUCTION (1)
SAMPLING / TESTING OF
PORTLAND CEMENT CONCRETE
Date of Report Job No.
Event/Invoice No. Lab No.
Authorized By Date Sampled By Date Submitted By Date
Client Project Location Source of Sample Architect/Engineer Contractor Supplier Truck/Ticket No. Mix Identification Maximum Size Aggregate Batch Size Required Strength days Water Added Before Sampling Time In Mixer hours minutes Ambient Air Temperature Time Sampled
FRESHLY MIXED CONCRETE SAMPLED IN ACCORDANCE WITH
Deviations:
FRESHLY MIXED CONCRETE TESTED IN ACCORDANCE WITH DESIGNATED SPECIFICATIONS
Unit Weight; Temperature:
Air Content; % Slump;
Deviations:
CYLINDRICAL CONCRETE SPECIMENS MOLDED & CURED IN THE FIELD IN ACCORDANCE WITH
No. of Specimens Molded Diameter/Length Cross Sectional Area
Deviations:
CYLINDRICAL CONCRETE SPECIMENS CURED & TESTED IN THE LABORATORY IN ACCORDANCE WITH
COMPRESSIVE STRENGTHDate Time Tested Tested
Specimen Age Type of Fracture Marking In & Tested By
If Any Days Defects Noted Maximum Load Conformance
Indicated?
Comments:
Distribution :
THE SERVICES REFERRED TO HEREIN WERE PERFORMED IN ACCORDANCE
WITH THE STANDARD OF CARE PRACTICED LOCALLY FOR THE REFERENCED
METHOD(S) AND RELATE ONLY TO THE CONDITION(S) OBSERVED OR
SAMPLE(S) TESTED AT THE TIME AND PLACE STATED HEREIN. WESTERN
TECHNOLOGIES INC. MAKES NO OTHER WARRANTY OR REPRESENTATION
EXPRESSED OR IMPLIED, AND HAS NOT CONFIRMED INFORMATION
INCLUDING SOURCE OF MATERIALS SUBMITTED BY OTHERS.
REVIEWED BY _______________________________________