View the file

Other files

File Type Posted
Amendment 0007 Attachment 1 RFI Question Answer MATOC Solicitation.pdf PDF
Amendment 0007 Solicitation 36C26222R0044.pdf PDF
Amendment 0006 Solicitation 36C26222R0044.pdf PDF
Amendment 0005 Attachment 7 RFI Questions 28-51-119 B162 Geotechnical Evaluation Report.pdf PDF
Amendment 0005 Attachment 8 RFI Questions 28-51-119 Lab Pharmacy Soils Report.pdf PDF
Amendment 0005 Attachment 12 RFI 125 SF 24.pdf PDF
Amendment 0005 Attachment 5 RFI 24 Specification 32 12 16 Asphalt Paving.pdf PDF
Amendment 0005 Solicitation 36C26222R0044.pdf PDF
Amendment 0005 Attachment 15 Earthwork Fill Material Lab Rpt.pdf PDF
Amendment 0005 Attachment 10 RFI Questions 104-107 B162 Elevator Airflow.pdf PDF
Amendment 0005 Attachment 19 Testing_and_Inspection_Plans_Elevator_Pit_Footing_17.09.21_(28)_Day_Bre_14167911.pdf PDF
Amendment 0005 Attachment 2 RFI 11 Seed Project.pdf PDF
Amendment 0005 Attachment 1 RFI 2 Seed Project Physical_Access_Control__Data.pdf PDF
Amendment 0005 Attachment 9 RFI 34 EPDM Submittal.pdf PDF
Amendment 0005 Attachment 3 RFI Questions 20-104-107 B162 Elevator Drawings.pdf PDF
Amendment 0005 Attachment 6 RFI Questions 28-30-51-81-82 119 ED Soils Report.pdf PDF
Amendment 0005 Attachment 20 Testing_and_Inspection_Plans_Elevator_Pit_Walls_17.09.28_(7)_Day_Break_14167948.pdf PDF
Amendment 0005 Attachment 4 RFI Questions 20-104-107 B164 Elevator Drawings.pdf PDF
Amendment 0005 Attachment 13 RFI Questions 23-25-54-84 Additional Civil Specs.pdf PDF
Amendment 0005 FAR 52.216-22.pdf PDF
Amendment 0005 Seed Project RFI Questions and Answers.pdf PDF
Amendment 0005 Attachment 14 Earthwork Base Course Lab Rpt.pdf PDF
Amendment 0005 Attachment 11 RFI Questions 104 and 107 B162 Elevator Pit.pdf PDF
Amendment 0005 Attachment 16 ED Drainage Details.pdf PDF
Amendment 0005 Attachment 18 Proposed Lab_Pharmacy Bldg Plans_Hole locations.pdf PDF
Amendment 0004 Solicitation 36C26222R0044.pdf PDF
Amendment 0003 Solicitation 36C26222R0044.pdf PDF
Amendment 0002 Attachment 1 Site Visit Sign-In Sheet.pdf PDF
Amendment 0002 Solicitation 36C26222R0044.pdf PDF
Amendment 0001 Attachment 1 Site Visit Map - Bldg. 19.pdf PDF
Amendment 0001 Solicitation 36C26222R0044.pdf PDF
S02 Solicitation Attachment 2 Technical Proposal Data.docx DOCX document
Amendment 0001 Attachment 2 Seed Project Site Visit Information.pdf PDF
S02 Solicitation Attachment 3 Evaluation Ratings and Definitions.pdf PDF
S02 Solicitation Attachment 6 Contractor Surety Limitations.docx DOCX document
S02 Solicitation Attachment 4 Subcontractor Information And Consent.docx DOCX document
S02 Solicitation Attachment 1 Past Performance Questionnaire.docx DOCX document
S02 Solicitation Attachment 13 Seed Project Specifications.pdf PDF
S02 Solicitation Attachment 5 Bid Schedule - MATOC SEED Project.docx DOCX document
S02 Solicitation Attachment 12 Seed Project Drawings.pdf PDF
S02 Solicitation Attachment 9 Contractor Safety and EMR Info.docx DOCX document
S02 Solicitation Attachment 14 Seed Project Structural Calculations.pdf PDF
S02 Solicitation Attachment 7 Financial Disclosure Questionnaire.docx DOCX document
S02 Solicitation Attachment 2 Technical Proposal Data.docx DOCX document
S02 Solicitation Attachment 10 Seed Project Wage Determination.pdf PDF
S02 Solicitation Attachment 8 Location Capabilities Questionnaire.docx DOCX document
S02 Solicitation Attachment 11 Prescott Facility Map.pdf PDF
S02 Solicitation Attachment 15 Seed Project Statement of Work.pdf PDF
S02 Solicitation 36C26222R0044.pdf PDF
Show all 49

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

JB

JB

JB

W

(2)

(3)

W

(CONT.)ELECTRICAL GENERAL NOTES:

T

ELECTRICAL SYMBOL LIST:

MC

D

T

ELECTRICAL SYMBOL LIST:

EPM ELECTRICAL POWER MODULE

EXIT SIGN

2 X 2 EMERG. LED LIGHT FIXTURE WITH DRIVER

PP

DATA OUTLET-3 DATA PORTS

MOUNTING TO BE +18" A.F.F. UNLESS OTHERWISE NOTED

TELEPHONE- SINGLE GANG TELEPHONE OUTLET, 18" A.F.F.

(W= 48" A.F.F.), STUB CONDUIT 6" INTO

ACCESSIBLE CEILING SPACE UNLESS NOTED OTHERWISE

ELECTRICAL SYMBOL NOTES:

2 X 4 EMERG. LED LIGHT FIXTURE WITH DRIVER

2 X 4 LED LIGHT FIXTURE WITH DRIVER

2 X 2 LED LIGHT FIXTURE WITH DRIVER

LED DOWNLIGHT WITH DRIVER

DATA OUTLET-2 DATA PORTS

MOUNTING TO BE +18" A.F.F. UNLESS OTHERWISE NOTED

POWER POLES FOR POWER AND COMMUNICATIONS FOR LAB &

PHARMACY - SINGLE POLE W/ DIVIDER FOR COMMUNICATIONS:

(PROVIDED BY FURNITURE VENDOR.) E.C. TO PROVIDE ALL

WIRING AND RECEPTACLES.

COMBINATION MOTOR STARTER AND DISCONNECT SWITCH, SIZE AND RATING AS

NOTED ON DRAWINGS. REFER TO MECHANICAL EQUIPMENT SCHEDULE FOR

ADDITIONAL INFORMATION

THERMOSTAT JUNCTION BOX MOUNTED 54" A.F.F. UNLESS OTHERWISE NOTED.

FUSED DISCONNECT SWITCH, SIZE AND RATING AS NOTED ON DRAWING

NON-FUSED DISCONNECT SWITCH, SIZE AND RATING AS NOTED ON DRAWINGS

ELECTRICAL PANEL

MOTOR CONNECTION

PUSH PLATE FOR AUTOMATIC DOORS

JUNCTION BOX WITH FLEXIBLE CONDUIT CONNECTION

JUNCTION BOX WALL MOUNTED

JUNCTION BOX CEILING MOUNTED

SPECIAL PURPOSE RECEPTACLE, VOLTAGE, RATING AND MOUNTING AS NOTED ON PLANS

CEILING MOUNTED DUPLEX RECEPTACLE, 120V, 20 AMPERE

DUPLEX RECEPTACLE, 120V, 20 AMPERE RATED 6" ABOVE FINISHED COUNTER TOP OR

BACK SPLASH MOUNTED HORIZONTALLY. AT LOCATIONS WHERE THERE IS NO COUNTER

TOP, RECEPTACLE SHALL BE MOUNTED 42" A.F.F.

SINGLE RECEPTACLE, 120V, 20 AMP RATED, SPECIFICATION GRADE, MOUNTED

HORIZONTALLY 6" TO CENTERLINE, OF RECEPTACLE ABOVE

COUNTER/BACK/SPLASH/DESK.

DOUBLE DUPLEX RECEPTACLE, 120V, 20 AMP RATED 18" A.F.F. UNLESS OTHERWISE

NOTED. MOUNTED IN COMMON JUNCTION BOX.

DESCRIPTIONSYMBOLDESCRIPTIONSYMBOL

ABOVE FINISHED FLOOR

ELECTRICAL CONTRACTOR

INDICATES FIXTURE CONNECTED TO EMERGENCY SERVICE

ELECTRIC WATER COOLER

GROUND FAULT INTERRUPTER

GROUND INDICATES GREEN GROUND CONDUCTOR CONNECTED TO EQUIPMENT AND

PANEL

NIGHT LIGHT, 24 HOUR OPERATION

UNLESS NOTED OTHERWISE

WEATHERPROOF

SINGLE POLE TOGGLE SWITCH, 20 AMPERE RATED, MOUNTED 48" A.F.F. UNLESS NOTED

OTHERWISE.

SUBSCRIPT: "a" - LOWER CASE LETTER INDICATES SWITCH CONTROL

THERMAL OVERLOAD TOGGLE SWITCH WITH PROPERLY SIZED HEATER ELEMENTS, 48"

A.F.F. UNLESS EQUIPMENT MOUNTED

SINGLE POLE SLIDE TYPE ARCHITECTURAL INCANDESCENT DIMMER SWITCH WITH FINS,

1200 WATT CAPACITY (LUTRON NOVA SERIES OR LEVITON). ALL NON-DIMMING SWITCHED

ADJACENT TO OR IN SAME ROOM SHALL BE THE SLIDE TYPE TO MATCH DIMMERS.

"LV" - DENOTES LOW VOLTAGE DIMMER TO MATCH ABOVE

SUBSCRIPT: "FD" - DENOTES FLUORESCENT DIMMER TO MATCH ABOVE

"IG" - DENOTES ISOLATED GROUND TYPE RECEPTACLE HUBBELL OR

LEVITON #IG-5362

SUBSCRIPT: "GFI" - DENOTES GROUND FAULT INTERRUPTER TYPE

RECEPTACLE

DUPLEX RECEPTACLE, 120 VOLT, 20 AMPERE RATED, 18" A.F.F. UNLESS NOTED

OTHERWISE. HUBBELL OR LEVITON #5362-I, MTD HORIZONTALLY IN JUNCTION BOX.

TOGGLE MOMENTARY CONTACT SWITCH WITH CENTER OFF POSITION

"3W" - DENOTES THREE WAY TOGGLE SWITCH

"2P" - DENOTES TWO POLE TOGGLE SWITCH

"P" - DENOTES LIGHTED HANDLE TOGGLE SWITCH, LIGHT IN

SWITCH SHALL LIGHT WHEN EQUIPMENT IS OPERATING

"4W" - DENOTES FOUR WAY TOGGLE SWITCH

A.F.F.

E.C.

EM

EWC

GFI

GND

NL

U.N.O.

WP

WIREMOLD 4000 W/ DIVIDER FOR LOW VOLTAGE

DATA OUTLET-1 DATA PORT

MOUNTING TO BE +18" A.F.F. UNLESS OTHERWISE NOTED

1. ELECTRICAL CONTRACTOR SHALL REVIEW ENTIRE SET OF CONTRACT DOCUMENTS: INCLUDING BUT NOT NECESSARILY LIMITED TO ALL ARCHITECTURAL, ALL STRUCTURAL, ALL MECHANICAL, ALL ELECTRICAL, ALL

PLUMBING, AND ENTIRE PROJECT MANUAL. ELECTRICAL CONTRACTOR SHALL ACKNOWLEDGE AND

INCLUDE IN THE SCOPE OF WORK (CONTRACT) ALL CONDITIONS PERTINENT TO THE COMPLETION OF THE ELECTRICAL WORK. ELECTRICAL CONTRACTOR SHALL FULLY COORDINATE ELECTRICAL WORK WITH THE INSTALLATION OF WORK BY ALL OTHER TRADES AND MAKE NECESSARY FIELD ADJUSTMENTS AS REQUIRED TO ACCOMMODATE THE ELECTRICAL INSTALLATION. ALL OF THE ABOVE SHALL BE INCLUDED IN THE SCOPE

OF WORK AT NO ADDITIONAL COST TO THE OWNER.

2. ELECTRICAL CONTRACTOR SHALL CAREFULLY EXAMINE THE DRAWINGS AND SPECIFICATIONS, VISIT THE SITE OF THE WORK, AND FULLY INFORM HIMSELF AS TO ALL CONDITIONS AND MATTERS THAT CAN, IN ANY WAY, AFFECT THE WORK OR THE COST THEREOF, SHOULD THIS CONTRACTOR FIND DISCREPANCIES IN, OR OMISSIONS FROM, THE DRAWINGS, SPECIFICATIONS OR OTHER DOCUMENTS OR BE IN DOUBT AS TO THEIR MEANING, NOTIFY THE OWNER AND ARCHITECT AT ONCE, IN WRITING, OF ANY DISCREPANCIES BETWEEN EXISTING CONDITIONS AND NEW WORK, OR BETWEEN ELECTRICAL WORK AND THE WORK OF OTHER TRADES PRIOR AND OBTAIN CLARIFICATION PRIOR TO SUBMITTING ANY BID. LACK OF SUCH NOTIFICATION

SHALL BE CONSTRUED TO INDICATE NO DISCREPANCIES OR CONFLICTS EXIST. ADDITIONAL

COMPENSATION WILL NOT BE GRANTED AFTER AWARD OF CONTRACT FOR ANY WORK REQUIRED TO

COMPLY WITH THESE REQUIREMENTS.

3. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO FURNISH AND INSTALL A COMPLETE ELECTRICAL SYSTEM. WHERE THERE IS NO MENTION OF THE RESPONSIBLE PARTY FOR A SPECIFIC ITEM TO BE FURNISHED, INSTALLED OR WIRED ON THE ELECTRICAL DRAWINGS, THE ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE COMPLETELY FOR ALL PURCHASES AND LABOR FOR A COMPLETE OPERATING SYSTEM

FOR THIS ITEM.

4. ANY MENTION OF A SPECIFIC VOLTAGE ON THE ELECTRICAL DRAWINGS SHALL NOT RELIEVE THE ELECTRICAL CONTRACTOR OF THE RESPONSIBILITY TO VERIFY THE VOLTAGE PRIOR TO PURCHASING OR

ROUGH-IN WORK.

5. ELECTRICAL CONTRACTOR SHALL VERIFY ALL OUTLET MOUNTING ARRANGEMENTS, HEIGHTS AND LOCATIONS WITH THE ARCHITECTURAL DRAWINGS PRIOR TO ROUGH-IN. ANY MENTION OF A SPECIFIC MOUNTING ARRANGEMENT, HEIGHT OR LOCATION SHALL NOT RELIEVE THE ELECTRICAL CONTRACTOR OF THE RESPONSIBILITY TO VERIFY THE SPECIFIC REQUIREMENT WITH THE EQUIPMENT FURNISHED OR THE OTHER TRADES WORKING IN THE SAME AREA. NO ADDITIONS TO THE CONTRACT SUM WILL BE PERMITTED FOR OUTLETS IN WRONG LOCATIONS, IN CONFLICT WITH OTHER WORK ETC. THE OWNER RESERVES THE RIGHT TO RELOCATE ANY DEVICE 10'-0" PRIOR TO ROUGH-IN WITHOUT ANY ADDITIONAL CHARGES BY THE

ELECTRICAL CONTRACTOR.

6. ALL INSTRUMENTS, APPARATUS AND EQUIPMENT SHALL BE TESTED AND PROVED TO BE ELECTRICALLY AND MECHANICALLY WITHOUT DEFECTS. THE ELECTRICAL SYSTEM SHALL BE TESTED FOR GROUNDS OR SHORTS AND IF SHORTED OR GROUNDED, ALL SUCH WIRES SHALL BE REMOVED AND REPLACED. IF TROUBLE IS WITHIN CIRCUIT, ALL METERS, CABLES, EQUIPMENT OR APPARATUS NECESSARY FOR MAKING

ALL TESTS SHALL BE FURNISHED AND PROVIDED BY ELECTRICAL CONTRACTOR.

7. ELECTRICAL CONTRACTOR SHALL ESTABLISH SAFE WORKING PROCEDURES FOR THE PROTECTION OF THE WORKMEN IN ALL PHASES OF WORK, COMPLYING WITH THE APPLICABLE PROVISIONS OF ALL CITY, STATE, AND FEDERAL SAFETY LAWS (OSHA), AND AS RECOMMENDED IN THE "MANUAL OF ACCIDENT PREVENTION IN CONSTRUCTION" AS ISSUED BY THE ASSOCIATION OF GENERAL CONTRACTORS OF AMERICA, INC., 20TH

AND E. STREETS, N.W. WASHINGTON, D.C.

8. THE CONSULTING ENGINEER MAY MAKE PERIODIC VISITS TO THE JOB SITE TO OBSERVE THE PROGRESS OF THE WORK AND TO OBSERVE WHETHER OR NOT IT IS BEING PERFORMED IN ACCORDANCE WITH THE ELECTRICAL PLANS AND SPECIFICATIONS. THIS DOES NOT IN ANY WAY MEAN THAT THE ENGINEER IS A GUARANTOR OF THE CONTRACTOR'S WORK, OR RESPONSIBLE FOR SAFETY IN, ON, OR ABOUT THE JOB SITE, IN CONTROL OF THE SAFETY OR ADEQUACY SAFETY OR ADEQUACY OF ANY SHIPMENT, BUILDING, SCAFFOLDING, FORMS OR OTHER WORK AIDS, OR FOR SUPERINTENDING, DIRECTING OR HAVING CHARGE

AT THE ERECTION AND/OR CONSTRUCTION OF THE WORK.

9. UPON COMPLETION OF THE WORK, THE ELECTRICAL CONTRACTOR SHALL REVIEW AND CHECK THE ENTIRE PORTION OF WORK, CLEAN EQUIPMENT AND DEVICES, REMOVE SURPLUS MATERIALS AND RUBBISH FROM THE OWNER'S PROPERTY, LEAVING THE WORK IN NEAT AND CLEAN ORDER AND IN COMPLETE WORKING CONDITION. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL OF ANY CARTON, DEBRIS, ETC. FOR EQUIPMENT INSTALLED BY THIS CONTRACTOR INCLUDING EQUIPMENT FURNISHED BY THE OWNER. THE ABOVE SHALL ALSO APPLY TO ALL EQUIPMENT FURNISHED BY OTHERS AND UNPACKED

OR REMOVED FROM CARTON, BY THE ELECTRICAL CONTRACTOR.

10. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR SCHEDULING DELIVERY, RECEIVING, UNLOADING, UNCRATING, STORING SETTING IN PLACE, AND PROTECTING FROM DAMAGE, VANDALISM, THEFT OR

WEATHER DURING CONSTRUCTION FOR ALL NEW EQUIPMENT FURNISHED BY THE ELECTRICAL

CONTRACTOR.

11. THE ELECTRICAL CONTRACTOR SHALL PAY ALL PERMIT FEES, PLAN REVIEW FEES, LICENSE FEES, INSPECTIONS AND TAXES APPLICABLE TO THIS DIVISION AND SHALL BE INCLUDED IN THE BASE BID AS PART

OF THIS CONTRACT.

12. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL TEMPORARY WIRING FOR HAND TOOLS AND CONSTRUCTION LIGHTING PER LATEST OSHA STANDARDS AND INCLUDE ALL COSTS IN THE BASE BID.

13. ELECTRICAL CONTRACTOR SHALL GUARANTEE ALL WORK AND MATERIALS FOR A PERIOD TO BE

COORDINATED WITH VA REQUIREMENTS. AFTER THE FINAL ACCEPTANCE BY THE OWNER/COR.

14. ELECTRICAL CONTRACTOR SHALL FURNISH CONTRACT RECORD DOCUMENTS TO THE

ARCHITECT/ENGINEER BEFORE FINAL PAYMENT WILL BE ISSUED. THE CONTRACT RECORD DOCUMENTS SHALL DIAGRAMMATICALLY INDICATE THE INSTALLED CONDITION AND BE IN REPRODUCIBLE DRAWING

FORM.

15. THE ELECTRICAL INSTALLATION IS TO BE IN ACCORDANCE WITH ALL NATIONAL, STATE, LOCAL ELECTRICAL CODES AND LOCAL UTILITY COMPANY'S REQUIREMENTS. ANY MODIFICATION'S AND/OR ADDITIONS TO

THESE PLANS, REQUIRED FOR PROPER COMPLIANCE TO ANY APPLICABLE CODES SHALL BE THE

RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR AND SHALL BE INCLUDED IN HIS/HER BASE BID.

16. ALL EQUIPMENT/DEVICES SHALL BE NEW AND/OR FIRST QUALITY AND IS TO BEAR THE APPROPRIATE UL OR

CSA APPROVED LABELS FOR SPECIFIC PURPOSE.

17. ALL WIRE AND CABLE SHALL BE COPPER ONLY, TYPE "THWN" OR "XHHW". MINIMUM WIRE SIZE TO BE #12 EXCEPT FOR CONTROL WIRE. ALL WIRE SIZE #10 AWG AND SMALLER SHALL BE SOLID. ALL CABLE #8 AWG AND LARGER SHALL BE STRANDED. FOR ALL UNDERGROUND SERVICE CONDUCTORS FROM THE UTILITY COMPANY TRANSFORMER TO THE SERVICE EQUIPMENT SHALL BE TYPE "RHH-RHW-USE" (CROSS-LINKED

POLYETHYLENE INSULATION).

18. ALL 20 AMPERE BRANCH CIRCUIT HOMERUNS 100' OR LONGER SHALL BE MINIMUM #10 AWG OR LARGER

SIZED TO LIMIT VOLTAGE DROP TO CODE REQUIREMENTS.

19. NO ROMEX OR BX WILL BE PERMITTED.

20. ALL WIRE SHALL BE INSTALLED IN THIN WALL (E.M.T.) CONDUIT UNLESS OTHERWISE NOTED. MINIMUM SIZE SHALL BE 3/4" EXCEPT FOR DROPS FOR DEVICES, SWITCH LEGS, TEMPERATURE CONTROL CONDUITS, WHERE INDICATED OR AS CALLED FOR ON DRAWINGS. ALL THINWALL FITTINGS SHALL BE OF THE STEEL

COMPRESSION GLAND TYPE.

21. ALL UNDERFLOOR, UNDERGROUND OR EXPOSED-TO-WEATHER CONDUIT SHALL BE HEAVYWALL

GALVANIZED RIGID STEEL. (G.R.S.), MINIMUM 3/4".

22. ALL CONDUITS 2" OR LARGER SHALL BE GALVANIZED RIGID STEEL OR INTERMEDIATE METAL CONDUIT (I.M.C.).

23. ELECTRICAL CONTRACTOR SHALL INSTALL SIZE OF CONDUIT SHOWN AND AS SCHEDULED ABOVE AND

SHALL NOT REDUCE SIZING OF CONDUITS TO SUIT WIRE FILL CAPACITY.

24. ALL CONDUIT FASTENERS, STRAPS, SUPPORTS ETC. MUST BE "BOLT-ON" GALVANIZED STEEL ON EXPOSED CONSTRUCTION AND IN WET AREAS. SNAP-ON BLACK METAL "CADDY" CLIPS IN METAL PARTITION WALLS AND ABOVE SUSPENDED CEILINGS WILL BE PERMITTED. ALL FASTENERS, STRAPS, CLIPS, ETC. SHALL BE UL

LISTED FOR THEIR USE.

25. NO CONDUITS SHALL BE ROUTED THROUGH HVAC AIR DUCTS.

26. ALL CONDUIT RACEWAYS SHALL BE CONCEALED IN OR WITHIN: WALLS, CEILING CAVITY, ROOF CONSTRUCTION (WHERE APPROVED), SLAB, GRADE, ETC. UNLESS OTHERWISE NOTED. ANY RACEWAY

THAT IS TO BE ROUTED EXPOSED SHALL BE APPROVED BY THE OWNER/COR AND SUCCESSFULLY

REVIEWED BY THE ARCHITECT. PRIOR TO INSTALLATION. ALL CONDUIT SHALL BE ROUTED PARALLEL OR PERPENDICULAR TO WALLS AND STRUCTURAL MEMBERS WITH 90° BENDS WHERE REQUIRED AND SHALL BE

RACKED. PULL AND JUNCTION BOXES SHALL BE HELD TO A MINIMUM.

27. NO WIREWAY, THROUGH OR JUNCTION SHALL BE UTILIZED WHERE MORE THAN 8 CONDUITS ARE ENTERING OR LEAVING. MULTIPLE WIREWAYS, TROUGHS OR JUNCTIONS SHALL BE UTILIZED. IN NO CASE SHALL

FEEDER OR CONDUIT OR CABLING BE MIXED WITH BRANCH CONDUIT.

28. NO CONDUITS SHALL BE ROUTED ON ROOF. ELECTRICAL CONTRACTOR SHALL COORDINATE ROOF PENETRATIONS WITH MECHANICAL PIPE CURBS. WHERE CONDUIT MUST BE RUN ON ROOF, IT SHALL BE RACKED WITH OTHER TRADES WHERE POSSIBLE OR PROVIDED WITH ITS OWN ROOF RACK SUPPORT

SYSTEM WITH PROPER ROOF PLATE SO AS NOT TO CAUSE DAMAGE TO ROOF COVERING.

29. ELECTRICAL CONTRACTOR SHALL FIREPROOF ALL CONDUIT OPENINGS BETWEEN FLOORS AND ANY INTERSPACE FIRE SEPARATION BLOCK WALLS WITH AN OWNER APPROVED UL LISTED FIRE RETARDANT

MATERIAL. AS SUCCESSFULLY REVIEWED BY THE ARCHITECT.

30. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL SLEEVES THRU WALLS AND CORING THRU FLOORS. ELECTRICAL CONTRACTOR SHALL WEATHERPROOF ALL PENETRATIONS THRU FOUNDATION AND

EXTERIOR WALLS.

31. FINAL EQUIPMENT CONNECTION TO PILOT CONTROL DEVICES SHALL BE MADE WITH 1'-0" MINIMUM LENGTH

OF FLEXIBLE CONDUIT CONNECTION (IE. SOLENOID VALVES, MOTORIZED DAMPERS, ETC.).

32. ELECTRICAL CONTRACTOR SHALL PROVIDE CIRCUITS AND FINAL POWER CONNECTIONS FOR FIRE

PROTECTION FLOW SWITCHES, TAMPER SWITCHES AND ALARM BELLS AS REQUIRED.

33. RECEPTACLES INDICATED FOR G.F.I. PROTECTION SHALL PROTECT RECEPTACLE INDICATED ONLY. AT LOCATIONS WHERE G.F.I. RECEPTACLES ARE INDICATED WITHIN 5' OFA PLUMBING FIXTURE AND IN SIGHT OF EACH OTHER, ELECTRICAL CONTRACTOR MAY ELECT TO USE ONE "FEED THRU" G.F.I. RECEPTACLE TO FEED "SLAVE" G.F.I. RECEPTACLE (S). G.F.I. CIRCUIT BREAKERS WILL NOT BE PERMITTED TO PROTECT

RECEPTACLES INDICATED FOR G.F.I. PROTECTION.

34. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR FIRE ALARM SYSTEM; REFER TO "FA" DRAWINGS.

OS

VS

CR

DB

PB

OSD

WAP

PC

NCL

OCCUPANCY SENSOR, DUAL TECHNOLOGY (PIR/ULTRASONIC)

VACANCY SENSOR

OCCUPANCY SENSOR WITH DIMMER

LUTRON OR EQUAL #MAESTRO MSCL-OP153M

PROXIMITY CARD READER

DOOR BELL

PUSH BUTTON

WIRELESS ACCESS POINT, PROVIDE CAT6 CABLE FROM WAP

TO IT CLOSET

CCTV CAMERA, ZOOM/PAN/TILT

PULL CORD, CONNECT TO NURSE CALL SYSTEM

NURSE CALL LIGHT

SURFACE MOUNTED (1) TELEPHONE AND (1) DATA OUTLET, 18" A.F.F.

W=WALL MOUNTED, 48" A.F.F.

SURFACE MOUNTED DUPLEX, EXPOSED CONDUIT.

OPEN CABLE LADDER TRAY

CRITICAL POWER (CP PANEL)

SAFETY POWER (SP PANEL)

REGULAR POWER (LP PANEL)

NOTE:

1. ALL "NORMAL" SWITCHES SHALL BE IVORY IN COLOR. "EMERGENCY" SWITCHES IN LAB & PHARMACY

SHALL BE RED.

2. ALL "NORMAL" RECEPTACLES SHALL BE IVORY IN COLOR AND "EMERGENCY" RECEPTACLES IN LAB &

PHARMACY SHALL BE RED.

3. ALL "NORMAL" COVER PLATES (SWITCHES, RECEPTACLES AND TELEPHONES) IN FINISHED AREAS SHALL

BE IVORY. IN "EMERGENCY AREAS", ALL SHALL BE RED.

SPEAKERS

CAT 6 DATA CABLE WITH WHITE

KEYSTONE.

(DATA=RJ45)

(TELEPHONE=RJ11)

CAT 6 DATA CABLE TO NEAREST IT ROOM

3/4" EMT CONDUIT STUBBED TO THE

NEAREST ACCESSIBLE CEILING

ORPLAN SYMBOL

CAT 6 DATA CABLE WITH BLACK

KEYSTONE. RJ45

CAT 6 DATA CABLE WITH

IVORY KEYSTONE. RJ45

CAT 6 DATA CABLE TO NEAREST IT ROOM

CAT 6 DATA CABLE TO NEAREST IT ROOM

3/4" EMT CONDUIT STUBBED TO THE NEAREST

ACCESSIBLE CEILING

PLAN SYMBOL

(2

CAT 6 DATA CABLE WITH BLACK

KEYSTONE. RJ45

BLANK FACEPLATE

CAT 6 DATA CABLE WITH IVORY

KEYSTONE. RJ45

CAT 6 DATA CABLE TO NEAREST IT ROOM

CAT 6 DATA CABLE TO NEAREST IT ROOM

1" EMT CONDUIT STUBBED TO THE NEAREST

ACCESSIBLE CEILING

PLAN SYMBOL

CAT 6 DATA CABLE TO NEAREST IT ROOM

CAT 6 DATA CABLE WITH WHITE

KEYSTONE. RJ45

(3

CAT 6 DATA CABLE WITH BLACK

KEYSTONE. RJ45

CAT 6 DATA CABLE WITH IVORY

KEYSTONE. RJ11

CAT 6 DATA CABLE TO NEAREST IT ROOM

CAT 6 DATA CABLE TO NEAREST IT ROOM

3/4" EMT CONDUIT STUBBED TO THE NEAREST

ACCESSIBLE CEILING

PLAN SYMBOL ( SURFACE, EXPOSED CONDUIT)

Project Number

Pl ot

D a te

Date

Location

ARCHITECT + ENGINEERS:CONSULTANTS: Drawing Title:

Approved: Project Director

Project Title

Checked Drawn

Drawing Number

Dwg. of

Building Number

Date:Revisions:

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

A

B

C

D

E

F

Office of Construction and Facilities Management on e ei gh th in ch o ne fo ot on e qu a rte r i nc h on e fo ot th re e ei gh th s i nc h on e fo ot on e ha lf in ch o ne fo ot th re e qu a rte rs in ch o ne fo ot on e in ch o ne fo ot on e a nd o ne h a lf in ch es o ne fo ot th re e in ch es o ne fo ot

6"

6"

6"

6"

PRESCOTT, ARIZONA

Fi le

-201 W. CUS HING S TREET

TUCS ON, AZ 85 718

T: 520.882.4484 F: 520.882.5560

100% BID DOCUMENT

/1

5/

2:

:1

P M

C :\U se rs

\d bi bb s\

D oc um en ts \1

3-

E

LC

D

_d bi bb s.

rv t

ELECTRICAL GENERAL NOTES & SYMBOLS LIST

E001

13-127

JSNS

CLINICAL LABORATORY AND

PHARMACY BUILDING

12/03/2015

3/32" = 1'-0"E001 1 Telephone or Data Port Face Plate

3/32" = 1'-0"E001 2 Two Data Port Face Plate

3/32" = 1'-0"E001 3 Three Data Port Face Plate

3/32" = 1'-0"E001 4 One Telephone and One Data Port Face Plate

Bidding Document Revision 1 Nov. 02, 2015 BID SUBMISSION Dec. 03, 2015

BUS AMP

CONN. LOADISOLATED GND BUS

100% NEUTRAL

200% NEUTRAL

PHASE

TOTAL CONN. LOAD

A B10825 C7895

29190

10470

MOUNTING

SEMI-RECESS

LOCATION

LOAD TYPE

EM-UL1

NAME

LOAD (VA)

A B C

120/208V

LOAD (VA)

A

3PH, 4W

B

VOLTAGE

AMPS

VA

VA

MAIN O.C.

DEVICE

MLO

LOAD TYPE

C

200A

SIZE

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

UPPER LEVEL

3REC+L5

L1+L3+L4+1REC

3REC+L24

3REC

L19

L62+L85

4REC

L64

SPARE

SPARE

SPARE

3REC

3REC+L23

4REC

3REC

L10 (SERVER)

L83+3REC

L84+3REC

L12

UPS L14, FEED L9

4REC

4REC

4REC

500720

3REC

L65+3REC

BUS AMP

CONN. LOADISOLATED GND BUS

100% NEUTRAL

200% NEUTRAL

PHASE

TOTAL CONN. LOAD

A B15060

C12925

39165

11180

MOUNTINGLOCATION

LOAD TYPE

EM-UL2

NAME

LOAD (VA)

A B C

120/208V

LOAD (VA)

A

3PH, 4W

B

VOLTAGE

MAIN O.C.

DEVICE

MLO

LOAD TYPE

C

200A

SIZE

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

UPPER LEVEL

L70

L50,L54

L55

L73+L48+L46

5REC

L40

3REC

6REC

L44

L45

L87

L88

6REC

5REC

6REC

5REC

20A

20A

20A

20A

5REC+L72

L43

L56

6REC

6REC

1200 1200

BUS AMP

CONN. LOADISOLATED GND BUS

100% NEUTRAL

200% NEUTRAL

PHASE

TOTAL CONN. LOAD

A B16840

C16540

48220

14840

MOUNTING

SURFACE

LOCATION

LOAD TYPE

PP-PENT-1

NAME

LOAD (VA)

A B C

LOAD (VA)

A B

VOLTAGE

MAIN O.C.

DEVICE

MLO

LOAD TYPE

C

400A

SIZE

20A

20A

20A

20A

20A

20A

20A

20A

PENTHOUSE

ACCU-1 2000

1450ACCU-2

GMU-1 (1/2HP)

SPARE

SPARE

EF-3 (1/4HP)

EF-4 (1/2HP)

HWP-1 (5HP)

EF-5 (1/2HP)

UH-3, UH-4

SPARE

SPARE

SF-5 (5HP)

HWP-2

(STANDBY 5HP)

STRF-1

(3HP)

STRF-2

(10HP)

STRF-3*

(10HP)

BUS AMP

CONN. LOADISOLATED GND BUS

100% NEUTRAL

200% NEUTRAL

PHASE

TOTAL CONN. LOAD

A B8500

C10600

27600

MOUNTING

SURFACE

LOCATION

LOAD TYPE

PP-PENT-2

NAME

LOAD (VA)

A B C

LOAD (VA)

A B

VOLTAGE

MAIN O.C.

DEVICE

MLO

LOAD TYPE

C

200A

SIZE

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

30A

PENTHOUSE

HWP-3 (5HP)

SPARE

REC-PENTHOUSE

REC-ROOF

20A

20A

20A

20A

CP-1 (2)@ 1/3HP*

ROS-A & PUMP

HWCP-1 (1/2HP)

SPARE

SPARE

120/208V

3PH, 4W

HWP-4

(STANDBY 5HP)

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

BUS AMP

CONN. LOADISOLATED GND BUS

100% NEUTRAL

200% NEUTRAL

PHASE

TOTAL CONN. LOAD

A B10300

C9200

28300

MOUNTING

SURFACE

LOCATION

LOAD TYPE

PP-LL

NAME

LOAD (VA)

A B C

LOAD (VA)

A B

VOLTAGE

MAIN O.C.

DEVICE

MLO

LOAD TYPE

C

200A

SIZE

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

LOWER LEVEL

SF-2 & RF-2

SPARE

SPARE

SPARE

SPACE

20A

EF-1

EF-2

CUH1,UH1,UH2

GMU-2 (1/2HP)

SPARE

SINK-ELEC EYE

120/208V

3PH, 4W

SPACE

SPACE

SPACE

SPACE

SPACE

SPACE

HUM-3

SPACE

SPACE

SPACE

SPACE

SPACE

SPARE

SPARE

RECEP. CRAWL AHU-2

SPACE

SPACE

SPACE

SPACE

SPACE

SPACE

SPACE

SPACE

SPACE

SPARE

SPARE

SPARE

SPARE

SPARE

BUS AMP

CONN. LOADISOLATED GND BUS

100% NEUTRAL

200% NEUTRAL

PHASE

TOTAL CONN. LOAD

A B12680

C9800

34700

12220

MOUNTINGLOCATION

LOAD TYPE

RP-UL

NAME

LOAD (VA)

A B C

LOAD (VA)

A B

VOLTAGE

MAIN O.C.

DEVICE

MLO

LOAD TYPE

C

200A

SIZE

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

UPPER LEVEL

4REC 116,119 720

GFI 109

20A

20A

20A

20A

TEF1,TEF2,CUH2

SINK/TOLT SENSR

120/208V

3PH, 4W

4REC 117,118

SPARE

SPARE

SPARE

6REC 109,104 SINK/TOLT SENSR

L25+L26+L27+1R

2REC

UPS L11,FEED L13

SPARE

SPARE

SPARE

SPARE

5REC

L52

L53

SPARE

SPACE

SPACE

SPACE

SPACE

IT 164

IT 164

L31

L36,L37

L33,L34,L38

L29,L30,2REC

L32,L74

L42

2REC 109

GFI 113

GFI 107,108

GFI 105,106

1REC

SPARE

IT ROOM 128

SPARE

2REC 128

6REC 129,130

GFI 131

GFI 127

GFI 127

2REC 127

4REC 133,132

1REC EXT 132

SPARE

DOORBELL

AMPS

VA

VA

AMPS

VA

VA

AMPS

VA

VA

AMPS

VA

VA

AMPS

VA

VA

HUM-1

HUM-4

1REC 134,135

2REC 136,137

6REC 137,138

3REC 130,132

BUS AMP

CONN. LOADISOLATED GND BUS

100% NEUTRAL

200% NEUTRAL

PHASE

TOTAL CONN. LOAD

A B11800

C10820

33520

10900

MOUNTINGLOCATION

LOAD TYPE

RP-LL

NAME

LOAD (VA)

A B C

LOAD (VA)

A B

VOLTAGE

MAIN O.C.

DEVICE

MLO

LOAD TYPE

C

200A

SIZE

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

LOWER LEVEL

5REC 01,06,02

GFI 003,005

GFI 004

SPARE

3REC 12,17,13

6REC 09,10

5REC 13,14

1REC 14

20A

20A

20A

20A

IT CLOSET 3REC

SPARE

AMPS

VA

VA

120/208V

3PH, 4W

REC 008

IT 011

IT 011

IT 011

IT 011

IT 011

EXTERIOR/CRAWL GFI

WATER PURIFIER

SINKS/TOILET-003/004

EWC

SUB FEED

RP-UL2

SEMI-RECESSSEMI-RECESS

SURFACE

EWC

EWC

EWC

EWC

EWC

EWC

BUS AMP

CONN. LOADISOLATED GND BUS

100% NEUTRAL

200% NEUTRAL

PHASE

TOTAL CONN. LOAD

A B7061

C4306

17167

MOUNTING

SURFACE

LOCATION

LOAD TYPE

EM-LTG-LL

NAME

LOAD (VA)

A B C

LOAD (VA)

A B

VOLTAGE

MAIN O.C.

DEVICE

MLO

LOAD TYPE

C

100A

SIZE

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

LOWER LEVEL

EXIT-PENTHOUSE,LL

EXIT, UL

SPARE

SP-1

EM LTG PENT, LL

EM LTG LAB

EM LTG PHARM

EM L 125,126,121

EM L 104,102,127

AMPS

VA

VA

BUS AMP

CONN. LOADISOLATED GND BUS

100% NEUTRAL

200% NEUTRAL

PHASE

TOTAL CONN. LOAD

A B5500

C4745

13675

MOUNTING

SURFACE

LOCATION

LOAD TYPE

LP-LL

NAME

LOAD (VA)

A B C

LOAD (VA)

A B

VOLTAGE

MAIN O.C.

DEVICE

MLO

LOAD TYPE

C

100A

SIZE

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

LOWER LEVEL

SPARE

OPEN ENTR. LIGHTS

CORRID 1,6,17,12

SPARE

LTG-104, BATH

SPARE

L-9,10,8,2,3,4

L-8,11,13,14

CRAWL SPACE

LTG-LL

SPACE

SPARE

AMPS

VA

VA

SP-1

ELEV. LTG/RECEPT.

IT-011

IT-011

FIRE/VOICE EVAC PNL

PIT LIGHT

SPARE

SPARE

SPARE

CCTV PANEL

SECURITY PANEL

LTG-EXT.REAR

SPARE

SPARE

SPARE

SPARE

TIMECLOCK

SPARE

20A

20A

20A

20A

20A

SPARE

PENTHOUSE LTG

SPARE

SPARE

SPARE

OPN ENTR. ROOF

EXT. SOFFIT (S3)

SPACE

SPACE

120/208V

3PH, 4W

SPARE

BOLLARD LIGHTS

120/208V

3PH, 4W

120/208V

3PH, 4W

- SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

20A

20A

20A

20A

20A

20A

20A

20A

20A

DSS-2

DSS-1

ALL `EM' CB SHALL BE LOCK-OUT TYPE.

(BLDG EM. PANEL)

(SERVES LAB) (SERVES LAB)

20A

20A

20A

30A

30A

*ELECTRICAL CONTRACTOR SHALL PROVIDE ASCO 918 TIMECLOCK OR EQUAL AND PHOTOCELL ON ROOF, 4-POLE. PANEL 'LP-LL', CCT. 1,3 & 17.

2000 30A

30A

BUS AMP

CONN. LOADISOLATED GND BUS

100% NEUTRAL

200% NEUTRAL

PHASE

TOTAL CONN. LOAD

A B3500

C1740

MOUNTING

SEMI-RECESS

LOCATION

LOAD TYPE

RP-UL2

NAME

LOAD (VA)

A B C

120/208V

LOAD (VA)

A B

VOLTAGE

AMPS

VA

VA

MAIN O.C.

DEVICE

MLO

LOAD TYPE

C

100A

SIZE

20A

20A

20A

20A

20A

20A

20A

20A

UPPER LEVEL

SINKS & TOILETS EYE

MONITORS 104

REFRIGERATOR 127

4R-110, 10

5R. 111, 114

3R. 111, 110, 114

1R. 109

3 GFI. 110, 113

SPACE

3R. 104

3R-112

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

20A

20A

20A

20A

20A

20A

IT ROOM 128

IT ROOM 128

IT ROOM 128

IT ROOM 128

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

SPACE

SPARE

SPARE

EF-6

SPACE

SPACE

SPACE

SPACE

SPACE

SPACE

SPACE

SPACE

SPACE

SPACE

SPACE

SPACE

*TO CONTROL PANEL

20A

20A

20A

20A

20A

AHU-2

AHU-5*

BUS AMP

CONN. LOADISOLATED GND BUS

100% NEUTRAL

200% NEUTRAL

PHASE

TOTAL CONN. LOAD

A B8480 C10140

24640

MOUNTINGLOCATION

LOAD TYPE

EM-UL5

NAME

LOAD (VA)

A B C

LOAD (VA)

A B

VOLTAGE

MAIN O.C.

DEVICE

MLO

LOAD TYPE

C

200A

SIZE

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

UPPER LEVEL

PNEUMATIC TUBE

5R

20A

20A

20A

20A

P57

P54,P53+2R

P56+P55+2R

P49+P48+P47

P42+P41

3R

120/208V

3PH, 4W

AMPS

VA

VA

SEMI-RECESS

SPARE

2R-122,124

P81

(SERVES PHARMACY)

20A

20A

20A

BUS AMP

CONN. LOADISOLATED GND BUS

100% NEUTRAL

200% NEUTRAL

PHASE

TOTAL CONN. LOAD

A B10530 C8690

29017

MOUNTING

SEMI-RECESS

LOCATION

LOAD TYPE

EM-UL3

NAME

LOAD (VA)

A B C

120/208V

LOAD (VA)

A

3PH, 4W

B

VOLTAGE

AMPS

VA

VA

MAIN O.C.

DEVICE

MLO

LOAD TYPE

C

200A

SIZE

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

UPPER LEVEL

L39

L35

L16

L15

L17

L8

L71

L28

1900 L41

L60

L61

(SERVES LAB)

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

20A

20A

20A

20ASPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

BUS AMP

CONN. LOADISOLATED GND BUS

100% NEUTRAL

200% NEUTRAL

PHASE

TOTAL CONN. LOAD

A B11410 C11860

34080

10810

MOUNTINGLOCATION

LOAD TYPE

EM-UL4

NAME

LOAD (VA)

A B C

LOAD (VA)

A B

VOLTAGE

MAIN O.C.

DEVICE

MLO

LOAD TYPE

C

200A

SIZE

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

20A

UPPER LEVEL

P1+P2+P3

6REC

6REC

6REC

6REC

P-29

P-30

P58,P59

P60,P61

P26,P27

P13,P12,P8

3R+P25

P11+P10+3R

P9+2R

3R

20A

20A

20A

20A

P23,P22,P21

P20,P18,P19

P45,P46,P44

P31

4R+P28

P36+3R

P37+P38

P40+3R

P35

P39+P52+2R

P32+P33+4R

P50+P51+2R

P67,P34

P15,P17,P16+2R

120/208V

3PH, 4W

P82

AMPS

VA

VA

SEMI-RECESS

SPARE

(SERVES PHARMACY)

20A

20A

20ASPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

P69,P71

DOOR OPERATOR

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

81 81

L20

L47,L49,L59

L75

L86

L22

L63

L57,L58,L66

L67,L68,L69

L89,L90

L91

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

P4

P24

P64,P65

P76,P77

P82

P5,P6,P7

P62,P63

P68

P70,P72

P79,P80

SPARE SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

AUTOMATIC DOOR

DOOR OPERATOR

DOOR OPERATOR

DOOR OPERATOR

*ADD ALTERNATE

41 42

1 2

ABC

41 42

1 2

ABC

41 42

1 2

ABC

41 42

1 2

ABC

41 42

1 2

ABC

41 42

1 2

ABC

41 42

1 2

ABC

1 2

ABC

1 2

ABC

41 42

1 2

ABC

41 42

1 2

ABC

41 42

1 2

ABC

41 42

1 2

ABC

Project Number

Pl ot

D a te

Date

Location

ARCHITECT + ENGINEERS:CONSULTANTS: Drawing Title:

Approved: Project Director

Project Title

Checked Drawn

Drawing Number

Dwg. of

Building Number

Date:Revisions:

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

A

B

C

D

E

F

Office of Construction and Facilities Management on e ei gh th in ch o ne fo ot on e qu a rte r i nc h on e fo ot th re e ei gh th s i nc h on e fo ot on e ha lf in ch o ne fo ot th re e qu a rte rs in ch o ne fo ot on e in ch o ne fo ot on e a nd o ne h a lf in ch es o ne fo ot th re e in ch es o ne fo ot

6"

6"

6"

6"

PRESCOTT, ARIZONA

Fi le

-201 W. CUS HING S TREET

TUCS ON, AZ 85 718

T: 520.882.4484 F: 520.882.5560

100% BID DOCUMENT

/1

5/

2:

:1

P M

C :\U se rs

\d bi bb s\

D oc um en ts \1

3-

E

LC

D

_d bi bb s.

rv t

ELECTRICAL PANEL SCHEDULES

E002

13-127

FPNS

CLINICAL LABORATORY AND

PHARMACY BUILDING

12/03/2015

ELECTRICAL NOTES

A. REFER TO DRAWING 164-E003 FOR ELECTRICAL/MECHANICAL SCHEDULE FOR FEEDER

SIZING AND CIRCUITS.

B. REFER TO DRAWING 164-Q601 & 164-Q602 FOR LAB AND PHARMACY EQUIPMENT LIST.

ELECTRICAL/MECHANICAL SCHEDULE

LIGHTING FIXTURE SCHEDULE

EQUIPMENT

AHU-1

AHU-2

AHU-5

STRF-1

EF-1

TEF-1

TEF-2

HUM-1

UH-1

CUH-1

SYSTEM

PACKAGED

SUPPLY FAN

STROBIC FAN

EXHAUST FAN

HUMIDIFIER

UNIT HEATER

CABINET UNIT HEATER

LOCATION

ROOF

PENTHOUSE

ROOF

LL

LL

PENT ROOF

ROOF

UL

UL

ROOF

LL

PENTHOUSE

LL

LL

LL

7.5 & 10 HP

3 & 15 HP

5 HP

3 HP

10 HP

1/2 HP

1/4 HP

150 WATTS

150 WATTS

3.4 KW

32.4 KW

1/60 HP

1/60 HP

1/8 HP

1/8 HP

0.03 HP

80/62

90/65

30/22

MCA

MDCP/

TOGGLE

DISCONNECT SWITCH

PROVIDE

EM-DP-LL

PP-PENT-1

PP-LL

PP-LL

PP-PENT-1

RP-UL

PP-PENT-2

PP-LL

PP-PENT-1

PP-LL

PANEL

ELECTRICAL

2/4/6

8/10/12

20/22/24

32/34/36

32/34

36/38

40/42

CCT.

3#4,#8GRD, 1-1/4"C

3#10, #10GRD, 3/4"C

3#12, #12GRD, 3/4"C

3#8, #10GRD, 1"C

3#8, #10GRD, 1"C

2#12, #12GRD, 3/4"C

3#3/0 #6GRD, 2"C

2#12, #12GRD, 3/4"C

FEEDER

208/3

208/3

120/1

120/1

VOLT/PAHSE NOTES

AHU-3

AHU-4

208/3

208/3

208/3

120/1

120/1

120/1

120/1

120/1

120/1

208/1

208/3

208/1

208/1

208/3

120/1

120/1

120/1

120/1

10 HP

1/2 HP

1/2 HP

1/2 HP

24.3 KW

1.6 KW

2 KW

150A/3P

200A/3P

ROOF

ROOF

PENT ROOF

ROOF

ROOF

PENTHOUSE

PENTHOUSE

STROBIC FAN

STROBIC FAN

EXHAUST FAN

EXHAUST FAN

EXHAUST FAN

EXHAUST FAN

EXHAUST FAN

EXHAUST FAN

HUMIDIFIER

HUMIDIFIER

HUMIDIFIER

HUMIDIFIER

UNIT HEATER

UNIT HEATER

UNIT HEATER

STRF-2

STRF-3

EF-2

EF-3

EF-4

EF-5

HUM-2

HUM-3

HUM-4

HUM-5

UH-2

UH-3

UH-4

PP-PENT-1

PP-PENT-1

PP-PENT-1

RP-UL

MSB-1

PP-PENT-2

PP-PENT-2

DP-PENTHOUSE

PP-LL

PP-PENT-1

2#12, #12GRD, 3/4"C

2#12, #12GRD, 3/4"C

2#12, #12GRD, 3/4"C

2#12, #12GRD, 3/4"C

2#12, #12GRD, 3/4"C

2#12, #12GRD, 3/4"C

2#12, #12GRD, 3/4"C

2#12, #12GRD, 3/4"C

2#12, #12GRD, 3/4"C

2#12, #12GRD, 3/4"C

2#12, #12GRD, 3/4"C

ACCU-1

DSS-1

ACCU-2

DSS-2

HWP-1

HWP-2 STANBY

HWP-3

CP-1

GMU-2

GMU-1

ROS-1

HWCP-1

DUCTLESS SPLIT SYSTEM

CONDENSING UNIT

HOT WATER PUMP

CONDENSATE PUMP

GLYCOL MAKE-UP UNIT

REVERSE OSMOSIS SYSTEM

DOMESTIC HW CIRC PUMP

LL

UL

ROOF

ROOF

PENTHOUSE

LL

PENTHOUSE

PENTHOUSE

1A

1A

18A

13A

5 HP

2 @ 1/3 HP

1/2 HP

3/4 HP & 1HP

1/6 HP

PP-PENT-1

PP-PENT-2

PP-PENT-2

PP-PENT-2

PP-LL

PP-PENT-1

PP-PENT-2

PP-PENT-2

1/3

5/7

1/3

5/7

19/21/23

25/27/29

1/3/5

7/9/11

2#12, #12GRD, 3/4"C

2#12, #12GRD, 3/4"C

3#10, #12GRD, 3/4"C

208/1

208/3

120/1

PP-PENT-1

PP-PENT-1

CONDENSING UNIT

HOT WATER PUMP

HOT WATER PUMP

HOT WATER PUMP

GLYCOL MAKE-UP UNIT

PENTHOUSE

PENTHOUSE

PENTHOUSE

PENTHOUSE

PENTHOUSE

5 HP

5 HP

5 HP

1/2 HP

PP-PENT-1

PP-PENT-1

PP-PENT-1

PP-PENT-1

PP-PENT-1

2#10, #12GRD, 3/4"C

2#12, #12GRD, 3/4"C

3#10, #12GRD, 3/4"C

3#10, #12GRD, 3/4"C

3#10, #12GRD, 3/4"C

2#12, #12GRD, 3/4"C

2#12, #12GRD, 3/4"C

2#12, #12GRD, 3/4"C

2#10, #12GRD, 3/4"C

2#12, #12GRD, 3/4"C

208/1

208/1

208/1

208/3

208/3

208/3

120/1

120/1

120/1

SP-1 LL TOOGLE EM-LTG-LL 11 2#12, #12GRD, 3/4"C 120/1

TOGGLE

TOGGLE

TOGGLE

TOGGLE

TOGGLE

TOGGLE

TOGGLE

TOGGLE

TOGGLE

TOGGLE

TOGGLE

TOGGLE

TOGGLE

TOGGLE

TOGGLE

30A DISC

TOGGLE

TOGGLE

TOOGLE

TOOGLE

TOOGLE

TOOGLE

1/2 HP

POWER TO CONTROL PANEL

120/1

DUCTLESS SPLIT SYSTEM

2#12, #12GRD, 3/4"C

2#10, #12GRD, 3/4"C

FIXTURE TAG DESCRIPTION MANUFACTURER LAMP TYPE WATTS GENERAL LOCATIONSYMBOL

F1 2'X4' RECESSED LED TROFFER W/DRIVER, 3500K, 6400 LUMENS METALUX OR EQUAL: 24SR-LD1-64-C-UNV-L830-CD1-U LED 71 OFFICES, LAB, PHARM

F1A METALUX OR EQUAL: 24SR-LD1-45-C-UNV-L835-CD1-U 46 CORRIDORS

F2 METALUX OR EQUAL: 22SR-LD1-29-S-UNV-L835-CD1-U 30 OFFICES/CORRIDORS

F3 4' STRIPLIGHT LENSED LED W/DRIVER, 3500K, 5200 LUMENS METALUX OR EQUAL: SNLED-LD1-52-LW-UNV-L835-CD1-U 53 CORRIDORS/JANITOR

F4

METALUX OR EQUAL: CLPF-24-2-A12125-LD3-3-HI-35-UNV

108 CORRIDORS

F5 2'X2' CLEAN RM LED W/DRIVER, FLANGED, 3500K, 5400 LUMENS 72 CLEAN RM

F6 2'X4' CLEAN RM LED W/DRIVER, FLANGED, 3500K, 7200 LUMENS METALUX OR EQUAL: CLPF-24-4-A12125-LD3-2-HI-35-UNV 94 CLEAN RM

F7 (10) INTERIOR CEILING PENDANT LED W/DRIVER, 4000K STILE OR EQUAL: PAVO SIP 1145762 (10) 1L13WDMT PTXX 130 CORRIDORS

S1 EXTERIOR WALL PACK LED W/PHOTOCONTROL LUMARK OR EQUAL: XT0R5APC1 40 EXTERIOR WALL

S2 BOLLARD LED W/DRIVER, 4000K, 1545 LUMENS FORMS & SURFACES OR EQUAL: LBLCO-604 17 EXTERIOR

EXIT LED EXIT SIGNAGE SURE-LITES OR EQUAL: LPX-6

9.5 W/LF

EXTERIOR

LED

LED

LED

LED

LED

LED

LED

LED

LED

LED

2'X4' RECESSED LED TROFFER W/DRIVER, 3500K, 4500 LUMENS

2'X2' RECESSED LED TROFFER W/DRIVER, 3500K, 2900 LUMENS

8' SURFACE STRIPLIGHT LENSED LED W/DRIVER, 3500K, 9900 LUMENS METALUX OR EQUAL: 8TSNLED-LD1-99-LW-UNV-L835-CD2-U

HWP-4 STANDBY

SUMP PUMP

VOLTAGE

F8

F9

8' INDUSTRIAL FLUOR LUMINAIRE W/(4) T5 LAMPS METALUX OR EQUAL: 8IAF-228T5-UNIV-EB2 136 PENTHOUSE/CRAWLFLUOR 120

RECESSED, FLANGED LINEAR LED W/ DRIVER 9.5 W/LFLED 120

F10 SURFACE LINEAR WITH DRIVER OPTOLUM OR EQUAL: FLLP-HO-35-C-S 4.5 W/FT GALLERY*LED 120

S3 RECESSED LED 6" DOWNLIGHT 28

EXTERIOR, BOXED CEILING

LED 120

HALO COMMERICAL OR APPROVED EQUAL

PD62OED0101EM - PDM6A835 - 61VL

FOCUL POINT OR EQUAL: SEEM2

FSM2L-TF-625-35K-IC-UNV

HISTORY WALL, FLANGED

FOR DRYWALL

NOTES

LENGTH AS PER PHYSICAL DIMENSIONS. HISTORY WALL RECESSED LTG. DETAIL, DWG. AS-311, DETAIL #04. AVAILABLE IN INCREMENTS OF 1.33".

S4 5' RECESSED STRIPLIGHT LENSED W/ DRIVER, 3500K, WET LOCATION FOCAL POINT OR EQUAL: SEEM2 #FSM2LWLFL62535K1CUNV

LED 120

INTERIOR

TEF-3 UL 150 WATTS - RP-UL 2 120/1EXHAUST FAN 2#12, #12GRD, 3/4"CTOGGLE

PART #SIP 145762.M (JOB ID# 95959)

PENDANT

LENGTH AS PER PHYSICAL DIMENSION. AVAILABLE IN INCREMENTS OF 1'.

PERFORATED 360° DESIGN

PACKAGED LOWER LEVEL PP-LL 1/3/5 3#3,#8GRD, 1-1/4"C 208/3

PACKAGED ROOF 2 & 3 HP 25/18 DP-PENTHOUSE 1 3#10,#10GRD, 3/4"C 208/3

PACKAGED ROOF 2 & 10 HP 60/44 EM-DP-LL 3 3#6,#10GRD, 1"C 208/3

LOAD

LEAVE WIRES COILED AND TAPED IN A BOX IN THE PENTHOUSE FOR FUTURE AHU-5

LEAVE WIRES COILED AND TAPED IN A BOX IN THE PENTHOUSE FOR FUTURE STRF-3

S5 35 EXTERIOR18" SURFACE MOUNTED LED LIGHT FIXTURE MCGRAW EDISON OR APPROVED EQUAL: TT-B2-LED-E1-MQ-AP LED 120

LEAVE WIRES COILED AND TAPED IN A BOX IN THE PENTHOUSE FOR FUTURE GMU-2

EF-6 UL TOOGLE RP-UL2 18 2#12, #12GRD, 3/4"C 120/11/8 HPEXHAUST FAN

Project Number

Pl ot

D a te

Date

Location

ARCHITECT + ENGINEERS:CONSULTANTS: Drawing Title:

Approved: Project Director

Project Title

Checked Drawn

Drawing Number

Dwg. of

Building Number

Date:Revisions:

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

A

B

C

D

E

F

Office of Construction and Facilities Management on e ei gh th in ch o ne fo ot on e qu a rte r i nc h on e fo ot th re e ei gh th s i nc h on e fo ot on e ha lf in ch o ne fo ot th re e qu a rte rs in ch o ne fo ot on e in ch o ne fo ot on e a nd o ne h a lf in ch es o ne fo ot th re e in ch es o ne fo ot

6"

6"

6"

6"

PRESCOTT, ARIZONA

Fi le

-201 W. CUS HING S TREET

TUCS ON, AZ 85 718

T: 520.882.4484 F: 520.882.5560

100% BID DOCUMENT

/1

5/

2:

:2

P M

C :\U se rs

\d bi bb s\

D oc um en ts \1

3-

E

LC

D

_d bi bb s.

rv t

LIGHTING FIXTURES AND

ELECTRICAL/MECHANICAL SCHEDULE

E003

13-127

FPNS

CLINICAL LABORATORY AND

PHARMACY BUILDING

12/03/2015

OS

VS

OS

VS

VS

VS

OS OS

VS

VS

OSD

OSD

.1

.5

G KFE

D E.3

F1 F1 F1

F1 F1 F1

F1 F1 F1

F1 F1 F1

F1a F1a F1a

F1a

F1a

F2 F2

F2

F2

F2

F2

F2F2

F2

F2

F2

F2

F2

F2

F1a

F1a

F1a

F1a

F1a

F1a

F1a

F1a

F2

F2

F2

F2

2d

2d

2d

2d

EM-2

2d

2d

2f

2f

EM-2

2f

2f

2f

2f5b

5b EM-25bEM-2

2c

2c

2c

F3

F3

F3

4a

EM-2

3W 5a

EM-1

5a

5b

3W 5b

3W 5a

EM-1

EM-1

5b

5b

5b

5b

EM-2

3W 5b

EM-1

EM-2EM-1

5c

F3

F3

4b

4b 4b

5d

5d

EM-2

4c

4c

4d

4d5d

2a 2b

2b

2bEM-2

2b2b

2b

2a

2a2a

EM-22a

2a

EM-1

F3 2f

EM-2

'EM-LTG-LL' 100A M.L.O.

120/208V, 3PH,4W

'LP-LL' 100A M.L.O.

120/208V, 3PH,4W

2c

ELEVATOR

EM-1

4d

4c

4a

2f2d

F3

F2

SWITCH FOR ELEVATOR

CAR LTG. & RECEPTACLE,

PANEL 'EM-LTG-LL', CCT.

EM-15

TIME

CLOCK

EM-2F3

F3

S1

S1

F3

F3

Project Number

Pl ot

D a te

Date

Location

ARCHITECT + ENGINEERS:CONSULTANTS: Drawing Title:

Approved: Project Director

Project Title

Checked Drawn

Drawing Number

Dwg. of

Building Number

Date:Revisions:

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

A

B

C

D

E

F

Office of Construction and Facilities Management on e ei gh th in ch o ne fo ot on e qu a rte r i nc h on e fo ot th re e ei gh th s i nc h on e fo ot on e ha lf in ch o ne fo ot th re e qu a rte rs in ch o ne fo ot on e in ch o ne fo ot on e a nd o ne h a lf in ch es o ne fo ot th re e in ch es o ne fo ot

6"

6"

6"

6"

PRESCOTT, ARIZONA

KEY PLAN

NORTH

Fi le

-201 W. CUS HING S TREET

TUCS ON, AZ 85 718

T: 520.882.4484 F: 520.882.5560

AREA

'A'

AREA

'C'

BUILDING

BUILDING

MIRACLE MILE

100% BID DOCUMENT

O

PE

N A

IR

E

N

TR

A N

C E

/1

5/

2:

:2

P M

C :\U se rs

\d bi bb s\

D oc um en ts \1

3-

E

LC

D

_d bi bb s.

rv t

LOWER LEVEL LIGHTING PLAN

EL101

13-127

JSNS

CLINICAL LABORATORY AND

PHARMACY BUILDING

12/03/2015

1/8" = 1'-0"EL101

1 LIGHTING PLAN - LOWER LEVEL

ELECTRICAL NOTES

A. ALL NORMAL LIGHTING TO PANEL 'LP-LL', U.N.O.

B. ALL EMERGENCY (EM) LIGHTING TO PANEL 'EM-LTG-LL', U.N.O.

OS

OS

OS

OS OS OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

VS

D B

D B

O S D

OS

O S D

O S D

OS OS

OS OS

OS OS

OSD

OSD

O S D

O S D

O S D

O S D

OS

OS

.1

.5

G KFE

D E.3

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1 F1

F1

F1

F1

F1

F2

F2

F1 F1F1

F1

F5 F5 F5 F5

F2 F2F2F2F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

4W

F2 F2

F2F2F2

F2 F2

F2 F2

F2

F2

F2

F1

F2

F3

3w3w4w

F2

4w4w

4w4w

4w

3w

F2

F2

F2 F2

F2 F2

F2

F2

F3 F3

4w

EM-4 EM-4 EM-4

EM-4 EM-4 EM-4

EM-4 EM-4 EM-4

EM-4 EM-4 EM-4

EM-4 EM-4 EM-4

EM-4 EM-4 EM-4

EM-4

EM-4

EM-4

EM-4

EM-4

EM-4EM-3

EM-3

EM-4

EM-10 EM-3

13a

EM-6 EM-6

EM-6 EM-6

EM-6 EM-6EM-6 EM-6

EM-6 EM-6EM-6

EM-6 EM-6EM-6

EM-6 EM-6EM-6

EM-6EM-6 EM-6

EM-3

EM-10

EM-3

13f

13f EM-6

8u 8v

8r 8s

8s 8t

8t 8p

8v

8m 8n 8x

EM-38x8x

EM-3

EM-3

13f

13f

EM-3

EM-10

E

M -8

EM-6

EM-3

8a8a

8b8b

8c 8c 13g

13g

13g

EM-10 13g 13g 13g EM-10EM-10EM-3

8e

8e

8f

8f

8g

8g

8h

8h

8j

8j

8l

8l

8k

8k

EM-8

EM-8

EM-8

EM-8

EM-8

E M

-6

EM-6

EM-6

EM-6

EM-6

EM-8

EM-8

E

M -8

EM-3

8w

8w

F2

8d

F6

EM-8

F6

EM-8

F2

Em-10

F2

13e

F2

13f

F2 Em-10

F2

13d F2

13b

13c

F2 8q

EM-10

13a

13a 13a

13a

13a

13a

13a

EM-10

13a

13a

13a

ELEVATOR

F2 F2

EM-3

F2 F2 F2 F2 F2

F2F2F2F2F2

F2 F2 F2 F2

EM-3

EM-4

E M

-4

4w

'24 HOUR' EMERGENCY LTG

(UNSWITCHED)

SWITCHED EMERGENCY LTG.

(TYPICAL IN LAB & PHARMACY)

8x8x 8n

8m

8p 8q

8r

8t

8v8u

8w

8a

8b

8c

8d

8k 8l

13e13d

13b

13c

F3 EM-2

EM-2F3

13a 13a 13a

F2 F2

S1

13g

F5 F5

EM-8EM-8

EM-8

F5

F5

EM-8

EM-8

EM-8

EM-8

F5

EM-8

EM-8

F1

S1

S1

S1

S1

S1

S1

S1

3w

S3

S3

EL104

F1

EM-4

OPEN AIR ENTRANCE

3W

3W

3W

3W

SWITCH BANK

Project Number

Pl ot

D a te

Date

Location

ARCHITECT + ENGINEERS:CONSULTANTS: Drawing Title:

Approved: Project Director

Project Title

Checked Drawn

Drawing Number

Dwg. of

Building Number

Date:Revisions:

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

A

B

C

D

E

F

Office of Construction and Facilities Management on e ei gh th in ch o ne fo ot on e qu a rte r i nc h on e fo ot th re e ei gh th s i nc h on e fo ot on e ha lf in ch o ne fo ot th re e qu a rte rs in ch o ne fo ot on e in ch o ne fo ot on e a nd o ne h a lf in ch es o ne fo ot th re e in ch es o ne fo ot

6"

6"

6"

6"

PRESCOTT, ARIZONA

KEY PLAN

NORTH

Fi le

-201 W. CUS HING S TREET

TUCS ON, AZ 85 718

T: 520.882.4484 F: 520.882.5560

AREA

'A'

AREA

'B'

AREA

'C'

BUILDING

BUILDING

MIRACLE MILE

100% BID DOCUMENT

O

PE

N A

IR

E

N

TR

A N

C E

/1

5/

2:

:2

P M

C :\U se rs

\d bi bb s\

D oc um en ts \1

3-

E

LC

D

_d bi bb s.

rv t

UPPER LEVEL LIGHTING PLAN

EL102

13-127

JSNS

CLINICAL LABORATORY AND

PHARMACY BUILDING

12/03/2015

1/8" = 1'-0"EL102

1 LIGHTING PLAN - UPPER LEVEL

ELECTRICAL NOTES

A. NORMAL LIGHTING TO PANEL 'LP-LL' LOCATED ON LOWER LEVEL.

B. EMERGENCY LIGHTING TO PANEL 'EM-LTG-LL' LOCATED ON LOWER LEVEL.

C. REFER TO DRAWING 'CS-102', REMOVE AND RELOCATE LIGHTING POLE

APPROXIMATELY 70'. EXTEND CIRCUITRY AS REQUIRED.

ELECTRICAL KEY NOTES

1. PROVIDE OCCUPANCY SENSOR TO BE COMPATIBLE WITH TOILET EXHAUST FAN. CONNECT

TOILET EXHAUST TO SAME OCCUPANCY SENSOR AS LIGHTING FIXTURES.

.5

G K

24a

24a

EM-2

24a

24a

24a

24a

24a

EM-2

24a

24a

OS

OS

OS

EM-1

F8

F8

F8

F8

F8

F8

F8F8

F8

F8

F8

F8

24aEM-224b 24b

NORMAL LIGHTING TO PANEL 'LP-LL', LOCATED ON LOWER LEVEL.

'EM' LIGHTING TO PANEL 'EM-LTG-LL' LOCATED ON LOWER LEVEL.

NORMAL LIGHTING TO PANEL "LP-LL" LOCATED ON LOWER LEVEL.

'EM' LTG TO PANEL 'EM-LTG-LL' LOCATED ON LOWER LEVEL.

S4

S4

S4

S4

S4

F3

24b

EM-2

S1 S1

Project Number

Pl ot

D a te

Date

Location

ARCHITECT + ENGINEERS:CONSULTANTS: Drawing Title:

Approved: Project Director

Project Title

Checked Drawn

Drawing Number

Dwg. of

Building Number

Date:Revisions:

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

A

B

C

D

E

F

Office of Construction and Facilities Management on e ei gh th in ch o ne fo ot on e qu a rte r i nc h on e fo ot th re e ei gh th s i nc h on e fo ot on e ha lf in ch o ne fo ot th re e qu a rte rs in ch o ne fo ot on e in ch o ne fo ot on e a nd o ne h a lf in ch es o ne fo ot th re e in ch es o ne fo ot

6"

6"

6"

6"

PRESCOTT, ARIZONA

KEY PLAN

NORTH

Fi le

-201 W. CUS HING S TREET

TUCS ON, AZ 85 718

T: 520.882.4484 F: 520.882.5560

BUILDING

BUILDING

MIRACLE MILE

PE

N

TH

O

US

E

100% BID DOCUMENT

O

PE

N A

IR

E

N

TR

A N

C E

/1

5/

2:

:2

P M

C :\U se rs

\d bi bb s\

D oc um en ts \1

3-

E

LC

D

_d bi bb s.

rv t

PENTHOUSE LIGHTING PLAN

EL103

13-127

JSNS

CLINICAL LABORATORY AND

PHARMACY BUILDING

12/03/2015

1/8" = 1'-0"EL103

1 LIGHTING PLAN - PENTHOUSE

ELECTRICAL NOTES

A. NORMAL LIGHTING TO PANEL 'LP-LL', LOCATED ON LOWER LEVEL.

B. 'EM' LIGHTING TO PANEL 'EM-LTG-LL'' LOCATED ON LOWER LEVEL.

.5

OPEN AIR ENTRANCE

S2

S2

S2

S2

S2

LINE OF ROOF ABOVE. SEE

ROOF PLAN THIS SHEET.

.5

S5

S5

S5

S5

S5

S5

S5

S5

S5

S5

S5

S5

Project Number

Pl ot

D a te

Date

Location

ARCHITECT + ENGINEERS:CONSULTANTS: Drawing Title:

Approved: Project Director

Project Title

Checked Drawn

Drawing Number

Dwg. of

Building Number

Date:Revisions:

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

A

B

C

D

E

F

Office of Construction and Facilities Management on e ei gh th in ch o ne fo ot on e qu a rte r i nc h on e fo ot th re e ei gh th s i nc h on e fo ot on e ha lf in ch o ne fo ot th re e qu a rte rs in ch o ne fo ot on e in ch o ne fo ot on e a nd o ne h a lf in ch es o ne fo ot th re e in ch es o ne fo ot

6"

6"

6"

6"

PRESCOTT, ARIZONA

KEY PLAN

NORTH

Fi le

-201 W. CUS HING S TREET

TUCS ON, AZ 85 718

T: 520.882.4484 F: 520.882.5560

AREA

'B'

AREA

'C'

BUILDING

BUILDING

MIRACLE MILE

100% BID DOCUMENT

O

PE

N A

IR

E

N

TR

A N

C E

/1

5/

2:

:3

P M

C :\U se rs

\d bi bb s\

D oc um en ts \1

3-

E

LC

D

_d bi bb s.

rv t

OPEN AIR ENTRANCE LIGHTING PLAN

EL104

13-127

JSNS

CLINICAL LABORATORY AND

PHARMACY BUILDING

12/03/2015

ELECTRICAL NOTES

A. PROVIDE 2 #10 & #10 GRD TO ALL EXTERIOR RECEPTACLES.

1/8" = 1'-0"EL104

1 OPEN AIR ENTRANCE LIGHTING PLAN - DEDUCT ALTERNATE 12

1/8" = 1'-0"EL104

2 OPEN AIR ENTRANCE ROOF LIGHTING PLAN - DEDUCT ALTERNATE 1

REF.REF.

R E

F.

FE

C

FE

C

FEC

FEC

FEC

FECFEC

R E

F.

GFI

SD

GFI

GFI

A

TS

G F I

G F I

G F I

G F I

G F I

G F I

GFI

GFI

.1

.5

G KFED E.3

REFER TO ELECTRICAL RISER

FOR QUANTITY, DWG. 164-EP601.

CORE THRU WALLS.

LAB

STORAGE

164-009

CORRIDOR

164-006

WOMEN'S

TOILET

164-004

MEN'S

TOILET

164-003

ELECTRICAL

ROOM

164-002

FUTURE

SPACE

164-007

PHARMACY

STORAGE

164-010

CORRIDOR

164-006

CORRIDOR

164-001

CORRIDOR

164-006

STAIR

S-1

MACHINE

ROOM

164-008

HAC

164-005

DELIVERY

164-017

IT

CLOSET

164-011

OFFICE

164-013

OFFICE

164-014

CORRIDOR

164-012

FUTURE

SPACE

164-015

PROVIDE (2) 4" SLEEVES

TO UPPER LEVEL

30A TWIST LOCK

RECEPTACLES, EM-LTG-LL,

CCT. EM-17

FUSED DISCONNECT SWITCH

AND SHUNT TRIP BREAKER.

DIESEL GENERATOR

175KW/219kVA, 120/208V, 3PH, 4W

SOUND ATTENUATION ENCLOSURE

1200 GALLON TANK.

TRANSFORMER IN UTILITY

YARD

MSB-1, 2500A MCB

120/208V, 3PH, 4W

DP-LL, 400A MLO

120/208V, 3PH, 4W

RP-LL, 200A MLO

120/208V, 3PH, 4W

LP-LL, 100A MLO

120/208V, 3PH, 4W

PP-LL, 200A MLO

120/208V, 3PH, 4W

600A, 120/208V, 3PH, 4W

EM-DP-LL, 600A MLO,

120/208V, 3PH,4W

EM-LTG-LL, 100A MLO

120/208V, 3PH,4W

CUH

31 AHU

ELEV.

HUM

VFD FOR SF-2

VFD FOR SF-2

DSS

VFD FOR RF-2

PROVIDE CAB LTG BRANCH

CCT & TELEPHONE FOR

ELEVATOR CAB.

SUMP PUMP & CONTROLLER PNL

'EM-LTG-LL', CCT. EM-11 & EM-13

PROVIDE PIT LTG W/WIREGUARD &

RECEPTACLE PNL 'EM-LTG-LL', CCT. EM-9

GFIGFI

UH

UH

EF

SP

4'x8' PLYWOOD FOR PHONE

SECURITY PNL EM-LTG-LL

CCT. 20

CCTV PNL EM-LTG-LL

CCT. 18

PP-LL CCT.41

30A TWIST LOCK

RECEPTACLES, EM-LTG-LL,

EM-19

8" REINFORCED STEEL

CONCRETE PAD

FRONT ACCESS ONLY

EXISTING MANHOLE #1

(2) 4" C IN

CONCRETE

DUCT BANK.

500kVA

12.47 kV:208/120V

3PH,4W

X

X

MECHANICAL

ROOM

164-016

EF

Project Number

Pl ot

D a te

Date

Location

ARCHITECT + ENGINEERS:CONSULTANTS: Drawing Title:

Approved: Project Director

Project Title

Checked Drawn

Drawing Number

Dwg. of

Building Number

Date:Revisions:

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

A

B

C

D

E

F

Office of Construction and Facilities Management on e ei gh th in ch o ne fo ot on e qu a rte r i nc h on e fo ot th re e ei gh th s i nc h on e fo ot on e ha lf in ch o ne fo ot th re e qu a rte rs in ch o ne fo ot on e in ch o ne fo ot on e a nd o ne h a lf in ch es o ne fo ot th re e in ch es o ne fo ot

6"

6"

6"

6"

PRESCOTT, ARIZONA

KEY PLAN

NORTH

Fi le

-201 W. CUS HING S TREET

TUCS ON, AZ 85 718

T: 520.882.4484 F: 520.882.5560

AREA

'A'

AREA

'C'

BUILDING

BUILDING

MIRACLE MILE

100% BID DOCUMENT

O

PE

N A

IR

E

N

TR

A N

C E

/1

5/

2:

:3

P M

C :\U se rs

\d bi bb s\

D oc um en ts \1

3-

E

LC

D

_d bi bb s.

rv t

LOWER LEVEL POWER PLAN

EP101

13-127

JSNS

CLINICAL LABORATORY AND

PHARMACY BUILDING

12/03/2015

1/8" = 1'-0"EP101

1 POWER PLAN - LOWER LEVEL

ELECTRICAL NOTES

A. ALL RECEPTACLES TO PANEL RP-LL, U.N.O.

B. REFER TO DRAWING 164-E003 FOR ELECTRICAL/MECHANICAL SCHEDULE FOR FOR

FEEDER SIZING AND CIRCUITS.

C. PROVIDE CONCRETE PADS FOR TRANSFORMER, MSB-1 AND GENERATOR. SIZES OF

PAD SHOWN APPROXIMATE. VERIFY W/ MANUFACTURER.

ELECTRICAL KEY NOTES

1. PROVIDE ELECTRICAL CONNECTION TO PHOTOELECTRIC 'EYE' OF SINKS AND TOILETS.

PANEL RP-LL, CCT.40

2. REFER TO DRAWING 164-T-101 FOR ADDITIONAL WORK.

3. REFER TO DRAWING 164-EP104 FOR PHYSICAL LOCATION OF EXISTING MANHOLE MH1

AND PROVIDE DUCT BANK AS SHOWN ON DRAWING 164-EP104.

FEC

FEC

SH

AR

PS

FEC

GFI GFI

GFI

GFI

GFI

G F I

GFI GFI

GFI GFI

GFI

GFI

G F I

G F I

GFI

G F I

J

HD

G F I

GFI

G F I

GFI

GFI

GFI

G F I

JJ

J

J

J

.1

.5

G KFE

D E.3

EXISTING CASEWORK TO

RECEIVE WIREMOLD,TYP

L70 L50 L54

L55 L52 L53 L73

L59

L47

L46

L72

L48

L43

L49

L44

L45

L86

L71

L8

L17

L15

L16

L41

L40

L39

L42

L74

L32

L30

L29

L38

L34

L33

L35

L36

L37 3

L56

L62

L57L58L66L67L68L69

L60

L19 L85 L83 L84

L63 L64

L28

L23L10L4L3L1L5L22

L26 L25 L24L27

3 5 26 28 30 7 7 9 7 7

181818

24 24 20

1616161414141414141212

25 252525 27 27 27 2929 29

19 191919 19 21 21 23 40 42

27 29

21 23

1515 1515 17 17 1717

9 9 9 9 11 13 13

16 16 2516 18 18

1212121214 14 14

7 7 7 7 5 55 5

1 1 1 31 3 3 3

6 6 6 86 8 36 8

2 2 10 2 4 4 4 4

22 22

L61

TO PANEL EM-UL2, U.N.O.TO PANEL EM-UL1, U.N.O.

TO PANEL EM-UL2, U.N.O.

26 26

P25

P67

P33

P32 P39 P52 P40

P37

P38

P36

P24

P28

P46

P19

P18

P15 P17 P16

P57

P54

P53 P55

P56

P13 P14

P30

P29

P2

P3

P6

P12

P11 P8

P9

P10P5P7

P50 P51

P49 P48 P47

P41P42

P31

20 39 16

LAB

164-115

40 40

3838383838

24 24 24 24

34 36

30 30 30 30

42 42

23 23 25 2525 25

1919191917171515

44222

PHARMACY

164-124

STERILE

PREP

164-126

CHEMO

164-125

MANAGER

OFFICE

164-137

SECRETARY

OFFICE

164-138

CORRIDOR

164-127

TOILET

164-131

LAB

MANAGER

OFFICE

164-130

PSA

OFFICE

164-129

IT

CLOSET

164-128

STAIR

S-2

VAULT

NARCOTICS

164-121

ASSISTANT

OFFICE

164-120

CORRIDOR

164-119

STORAGE

BH & AR

164-117

PASS-THRU

164-122

PROCUREMENT

STATION

164-118

PRIVATE

CONSULTATION

164-123

BLOOD

DRAW

164-112

WOMEN'S

TOILET

164-113

BLOOD

DRAW

164-114

PHLEBOTOMY

164-109

WAITING

164-104

ALCOVE

164-103

WOMEN'S

TOILET

164-105

MEN'S

TOILET

164-106

FAMILY

TOILET

164-107

HAC

164-108

BLOOD

DRAW

164-110

BLOOD

DRAW

164-111

DELIVERY

STORAGE

164-116

24/26 208V

28/30 208V

ELECTRICAL CONTRACTOR SHALL PROVIDE WIREMOLD.

RECEPTACLES SHALL BE 18" O.C.

9 9

21 21

3432323020

28282624

DOORBELL

CONNECTED TO

PUSHBUTTONS FROM

LOWER LEVEL, 120V.

30A TWIST LOCK RECEPTACLES

"EM-UL-2", CCT. 39 & 41

(2) 4" SLEEVE TO LOWER LEVEL

RP-UL 200A MLO

120/208V, 3PH, 4W

'EM-UL1' 200A MLO

120/208V, 3PH,4W

'EM-UL2' 200A MLO

120/208V, 3PH,4W

'EM-UL4',

200A MLO

120/208V, 3PH,4W

TO PANEL EM-UL3, U.N.O.

TO PANEL EM-UL3, U.N.O.

ELEVATOR

P81

TYPICAL POWER POLE W/ DIVIDER FOR COMMUNICATIONS

TYPICAL RECEPTACLE AT 18" A.F.F.

TYPICAL RECEPTACLE ABOVE COUNTERTOP

L20

72"AFF

42 42

WIREMOLD 4000 W/

DIVIDER BY ELECTRICAL

CONTRACTOR.

(TYP.)

VOICE EVACUATION

CONTROL PANEL

PANEL "EM-LTG-LL"

CCT.7

REFRIDGERATOR

RP-UL2, CCT.5

2 11

1 1

TEF

DSS

TEF

TEF

PNEUMATIC TUBE

RP-UL2 100A MLO

120/208V, 3PH, 4W

RP-UL2

RP-UL2

TO PANEL RP-UL2

RP-UL2

(2) RECEPTACLES, 65" AND 96" A.F.F.

PANEL "RP-UL2", CCT.3

(2) RECEPTACLES, 65" AND 96" A.F.F.

PANEL "RP-UL2", CCT.3

RECEPTACLE @ 72" A.F.F.

PANEL, "RP-UL2" CCT.3

35 33

4'x8' PLYWOOD

FOR PHONE

20 20 20 2024 24 24

LOW HEIGHT PARTITION

PROVIDE FLOOR CORES & FIRE

RATES STOP.

L87

L88

L12L12

L11L14

P82

L75

L31

L65

L2

L9L13

L89 L90

P64 P63

P62

P65

P68

P70

P71

P72 P69

P76 P77 P79

P80

'EM-UL5',

200A MLO

120/208V, 3PH,4W

'EM-UL3' 200A MLO

120/208V, 3PH,4W

OPEN

OFFICE

164-132

CLOSET

164-135

STERILE

PREP AIR

LOCK

164-134

CHEMO

AIR

LOCK

164-133

P27P26P60P58

P22 P21

P20 P23

P45 P44

P1

PPPPPPPP

PP PP

6 EM-UL-5

EM-UL-5

EM-UL-5

EM-UL-5

EM-UL-5

PP

PP

EF

OPEN AIR ENTRANCE

Project Number

Pl ot

D a te

Date

Location

ARCHITECT + ENGINEERS:CONSULTANTS: Drawing Title:

Approved: Project Director

Project Title

Checked Drawn

Drawing Number

Dwg. of

Building Number

Date:Revisions:

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

A

B

C

D

E

F

Office of Construction and Facilities Management on e ei gh th in ch o ne fo ot on e qu a rte r i nc h on e fo ot th re e ei gh th s i nc h on e fo ot on e ha lf in ch o ne fo ot th re e qu a rte rs in ch o ne fo ot on e in ch o ne fo ot on e a nd o ne h a lf in ch es o ne fo ot th re e in ch es o ne fo ot

6"

6"

6"

6"

PRESCOTT, ARIZONA

KEY PLAN

NORTH

Fi le

-201 W. CUS HING S TREET

TUCS ON, AZ 85 718

T: 520.882.4484 F: 520.882.5560

AREA

'A'

AREA

'B'

AREA

'C'

BUILDING

BUILDING

MIRACLE MILE

100% BID DOCUMENT

O

PE

N A

IR

E

N

TR

A N

C E

/1

5/

2:

:4

P M

C :\U se rs

\d bi bb s\

D oc um en ts \1

3-

E

LC

D

_d bi bb s.

rv t

UPPER LEVEL POWER PLAN

EP102

13-127

JSNS

CLINICAL LABORATORY AND

PHARMACY BUILDING

12/03/2015

1/8" = 1'-0"EP102

1 POWER PLAN - UPPER LEVEL

ELECTRICAL NOTES

A. RECEPTACLES IN LAB & PHARMACY AREAS TO RESPECTIVE 'EM' PANELS AS

INDICATED. RECEPTACLES IN OTHER AREAS (NON-LAB AND NON-PHARMACY) TO PANEL

'RP-UL', U.N.O.

B. REFER TO ELECTRICAL SCHEDULE DRAWING 164-E003 FOR

ELECTRICAL/MECHANICAL SCHEDULE FOR FEEDER SIZING AND CIRCUITS.

C. REFER TO DRAWING Q601 & Q602 FOR LAB & PHARMACY EQUIPMENT LIST.

D. MAXIMUM OF 30 CONDUCTORS IN WIREWAY SYSTEM. PROVIDE VERTICAL DROP AS

REQUIRED.

E. COORDINATE WITH MECHANICAL DRAWING AND INSTALL MECHANICAL CONTRACTOR

FURNISHED DISCONNECT SWITCHES TO COMPLY WITH NEC CODE REQUIREMENTS.

F. FURNISH AND INSTALL DISCONNECT SWITCHES AS REQUIRED TO COMPY WITH NEC

REQUIREMENTS.

ELECTRICAL KEY NOTES

1. IN ISLANDS ONLY, POWERPOLE FROM FLOOR TO TABLE AND WIRETROUGH BY

FURNITURE VENDOR. WIRING AND RECEPTACLE BY ELECTRICAL CONTRACTOR.

ELECTRICAL CONTRACTOR TO PROVIDE FLOOR CORES FOR ISLANDS. VERIFY EXACT

LOCATION WITH FURNITURE VENDOR AND OWNER PRIOR TO CORING FLOOR. PROVIDE

HORIZONTAL RUN OF CABLE & CONDUIT BELOW FLOOR. PROVIDE FIRE RATED STOP.

2. CONNECT TEF ALSO TO OCCUPANCY SENSOR/SWITCH. OCCUPANCY SENSOR SHALL BE

RATED FOR TEF.

3. PROVIDE ELECTRICAL CONNECTIONS TO PHOTOELECTRIC 'EYE' OF SINKS AND TOILETS.

PNL "RP-UL2", CCT.1

4. FLOOR CORES & PROVIDE CONDUIT & WIRING BELOW FLOOR. PROVIDE (1) 3/4"C FOR

POWER & 1-1/4"C FOR COMMUNICATIONS.

5. FLOOR CORES & PROVIDE CONDUIT & WIRING BELOW FLOOR. PROVIDE (1) 3/4"C FOR

POWER & (2) 1-1/4"C FOR COMMUNICATIONS.

6. ADA DOOR CONTROL OPERATOR ABOVE DOOR.

FE

C

G F I

G F I

G F I

.1

.5

GFE

D E.3

PENTHOUSE

164-201

STAIR

S-3

AHU

AHU

PP-PENT-1, 400A MLO, 120/208V, 3PH, 4W

ROS

DP-PENTHOUSE, 800A MLO, 120/208V, 3PH, 4W

PP-PENT-2, 200A MLO, 120/208V, 3PH, 4W

GMU

CP

HWP

HWP

STRF

STRF

ACCU

ACCU

VFD

VFD

CONTROL PANEL HUM-4

VFD FOR STRF-2

EF-5

CONTROL PANEL FOR HUM-3CONTROL PANEL FOR HUM-1

VFD FOR STRF-1

EF

VFD FOR SF-3VFD FOR SF-1

EF

EWH

EWH

VFD FOR SF-4

VFD FOR RF-4

VFD FOR HWP-1

VFD FOR HWP-2

HWP

HWP

(FOR RF-3)

BLOWER FOR TUBE

COORDINATE POWER

REQUIREMENTS WITH SWISSLOG.

(FOR RF-1)

HWCP

VFD FOR HWP-4

VFD FOR HWP-3

AHU

FUTURE

AHU

EF

EF

Project Number

Pl ot

D a te

Date

Location

ARCHITECT + ENGINEERS:CONSULTANTS: Drawing Title:

Approved: Project Director

Project Title

Checked Drawn

Drawing Number

Dwg. of

Building Number

Date:Revisions:

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

A

B

C

D

E

F

Office of Construction and Facilities Management on e ei gh th in ch o ne fo ot on e qu a rte r i nc h on e fo ot th re e ei gh th s i nc h on e fo ot on e ha lf in ch o ne fo ot th re e qu a rte rs in ch o ne fo ot on e in ch o ne fo ot on e a nd o ne h a lf in ch es o ne fo ot th re e in ch es o ne fo ot

6"

6"

6"

6"

PRESCOTT, ARIZONA

KEY PLAN

NORTH

Fi le

-201 W. CUS HING S TREET

TUCS ON, AZ 85 718

T: 520.882.4484 F: 520.882.5560

BUILDING

BUILDING

MIRACLE MILE

PE

N

TH

O

US

E

100% BID DOCUMENT

O

PE

N A

IR

E

N

TR

A N

C E

/1

5/

2:

:4

P M

C :\U se rs

\d bi bb s\

D oc um en ts \1

3-

E

LC

D

_d bi bb s.

rv t

PENTHOUSE POWER PLAN

EP103

13-127

JSNS

CLINICAL LABORATORY AND

PHARMACY BUILDING

12/03/2015

1/8" = 1'-0"EP103

1 POWER PLAN - PENTHOUSE

ELECTRICAL NOTES

A. ALL RECEPTACLES TO PANEL PP-PENT-2, U.N.O.

B. REFER TO ELECTRICAL SCHEDULE DWG. 164-E003 FOR FEEDER SIZES AND CIRCUITS FOR

MECHANICAL/PLUMBING LOADS.

1/8" = 1'-0"EP103

2 PENTHOUSE ELECTRICAL ROOF PLAN

PLASTIC

SPACER

INNERDUCT,

SEE NOTE 5

DUCT

[SIZE AS

INDICATED

ON DWGS.] 6-WAY DUCT LINE 4-WAY DUCT LINE

2-WAY DUCT LINE

GENERAL NOTES:

1.

2.

3.

4.

5.

CONCRETE SHALL BE 2000 P.S.I. @ 28 DAYS, OR AS SPECIFIED.

PROVIDE #4 REINFORCING RODS ON TOP AND BOTTOM OF

DUCTS WHEN CROSSING OR PLACED IN ROADWAYS.

MINIMUM COVER TO TOP OF ENVELOPE SHALL BE 610mm (24")

OR AS OTHERWISE SPECIFIED IN SECTION 26 05 41.

PROVIDE MINIMUM 152mm (6") SPACE BETWEEN POWER AND

TELECOMMUNICATION DUCTS. INCREASE SIZE AS REQUIRED.

INNERDUCT QUANTITY AND SIZE AS INDICATED ON PLANS.

TIE WIRE

(3")

(3")

76mm

(3 m m m

76mm

(3")

76mm m m

(3 m m

(3")

(3")

76mm

(3")

76mm76mm m m m m

76mm

(3")

76mm (3")

(3") 76mm

152mm

(6")(SEE NOTE 4)

(T Y P

EXISTING ELECTRICAL

EQUIPMENT

EXISTING MOTOR CONTROL

CENTER

EXISTING

TRANSFORMER

PM

EXISTING ONAN

GENERATOR

EXISTING MH1

PM

EXISTING

TRANSFORMER

EXISTING ELECTRICAL

EQUIPMENT

EXISTING CHILLER EXISTING CHILLER EXISTING CHILLER

EXISTING PUMPS

NEW DIESEL GENERATOR

NEW SWITCHGEAR

EXISTING AHU

NEW MEDIUM VOLTAGE

DUCTBANK (2) 4"C

SEE DETAIL 2 BELOW

EXISTING MEDIUM

VOLTAGE DUCT BANK

EXISTING UNDERGROUND

CHW LINES

NEW B164 TRANSFORMER

DEDUCT ALTERNATE 14

Project Number

Pl ot

D a te

Date

Loc…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .