Clarifications.docx
DOCX document 14 KB Posted
- Attached to
- Z2DA--Replace Obsolete Fire Alarm Devices, 537-16-101 Federal contract opportunity
- Solicitation number
- 36C25221B0003
About this file
This document includes a clarification file and a federal contract opportunity solicitation. The clarification file provides updates to the fire alarm system scope of work, including that all fire alarm panels, devices, and wiring shall be new except as outlined. It also confirms general carpentry and finish work is required to support the fire alarm installation.
The federal contract opportunity solicitation is for replacement of obsolete fire alarm devices at a VA medical center. The contractor shall provide all tools, materials, labor and supervision for a fully functional fire alarm system in accordance with construction documents. The project range is $2-5 million and work must be completed within 581 days of notice to proceed. The solicitation will be issued on November 25, 2020 with bids due January 14, 2021. The NAICS code is 238210 and the opportunity is restricted to SDVOSB firms. Offerors must be registered in SAM.gov and VIP database to be eligible for award.
View the file
Other files for this federal contract opportunity
Show all 33
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1. CHANGED: Section 28 31 00: 1.2 SCOPE A. A fully addressable fire alarm system shall be designed and installed in accordance with the specifications and drawings. Provide the devices as shown in plan.
B. Remove all old equipment and those conduits, wire molding, boxes and wiring that are readily accessible. Existing exposed conduit and conduit between drop-in tiles and the floor slab above is considered accessible. All fire alarm panels, initiation and indication devices shall be new. Except as outlined in Section 28 31 00 1.2C, D and E.
2. RFI 66 Response Updated:
RFI: Please confirm that there are no carpentry/finish requirements for this project? The last time this project was bid the intent was to move several of the panels into new/FA/Electrical closets adjacent to the stairwells. We have 08 11 13 hollow metal doors and frames, 08 14 00 interior wood doors, 08 71 00 hardware, 09 29 00 gypsum board in addition to the current specifications. Please confirm these are requirements are no longer required.
UPDATED RESPONSE: The project requires general carpentry work and finish requirements as it relates to supporting the fire alarm work. Examples include and are not limited to: fire stopping any new / abandoned fire alarm cable / conduit openings in rated walls for this work, painting and patching as required for demolition / new fire alarm work. Replace any ceiling tiles that are damaged or made dirty by this fire alarm work.