Attach I - RFI CM Buck 3.pdf

PDF 157 KB Posted

Attached to
Z1DA--Upgrade Campus Electrical Systems. Project No. 610A4-23-101.
Solicitation number
36C25026B0006_1
Issued by

About this file

This is a Request for Information (RFI) issued by the Department of Veterans Affairs, Network 10 Contracting Office, for the Upgrade Campus Electrical System project at VA Northern Indiana Healthcare System in Fort Wayne, Indiana. The RFI number is 36C25026B0006 with project number 610A4-23-101. Contractors submitting questions are required to thoroughly review all solicitation documents, specifications, and drawings before submitting inquiries and must specifically identify the relevant specification sections and drawing numbers in their questions. All questions must be submitted in a single document to Brian Rosciszewski, Contract Specialist, at Brian.Rosciszewski@VA.gov with the subject line "RFI – {Solicitation #} – Firm Name."

The RFI addresses three specific questions from CM Buck & Associates regarding electrical system upgrades. Question 1 concerns Section 26 05 73 Overcurrent Protective Device Coordination Study and requests clarification on whether all low voltage circuit breaker coordination settings and medium voltage relay settings must be provided regardless of equipment supplier. Question 2 addresses Section 26 13 13 Medium Voltage Circuit Breaker Switchgear, specifically whether NETA Circuit Breaker Testing is required on each individual circuit breaker. Question 3 addresses the same section and asks whether NETA testing of all main bus is required. Government responses, issued by MG Heapy on 3/2/26, confirm that all new equipment must be included in the Overcurrent Protective Device study per specifications and that NETA testing is required for both individual circuit breakers and main bus sections. The government indicates that RFIs will be answered by amendments issued to SAM.gov.

View the file

Other files

File Type Posted
36C25026B0006 0010.pdf PDF
36C25026B0006 0009.pdf PDF
Attach I - VAAR 852.236-92.pdf PDF
Attach II - Addendum 1 - Specs.zip ZIP file
36C25026B0006 0008.pdf PDF
Attach IV - Revised Bid Schedule 2.24.2026.pdf PDF
Attach I - Addendum 1 - Summary.docx DOCX document
Attach III - Addendum 1 - Drawings.zip ZIP file
Attach V - RFI CMBuck Rd. 2 - Revised.pdf PDF
36C25026B0006 0007.pdf PDF
36C25026B0006 0006.pdf PDF
Attach I - RFI Response CMBuck 2.pdf PDF
Attach II - Bid Schedule Revised 2.11.2026.pdf PDF
36C25026B0006 0005.pdf PDF
36C25026B0006 0004.pdf PDF
36C25026B0006 0003.pdf PDF
Attach III - RFI - Geotech.pdf PDF
Attach VI - RFI Richards.docx DOCX document
Attach II - RFI - Cornerstone.doc DOC document
Attach I - RFI - CMBuck.doc DOC document
Attach IV - RFI - IMS.doc DOC document
Attach V - RFI - Powergen.pdf PDF
Attach VII - RFI Valiant.docx DOCX document
Attach II - Final Geotechnical Report - 610A4-23-101.pdf PDF
Attach V - Fort Wayne ATS information.pdf PDF
Attach I - Wage Determination 1.30.2026.txt TXT text file
Attach III - Notice to Bidders on Bid Depth for Piles.docx DOCX document
Attach VI - 3W Data Closet Example.pdf PDF
Attach VII - IT standards ver 3.0 21 Aug 20.pdf PDF
36C25026B0006 0002.pdf PDF
Attach IV - Fort Wayne Generator Information.pdf PDF
Attach VIII - Fort Wayne PA information.pdf PDF
36C25026B0006 0001.pdf PDF
Attach II - Site Visit Notes.pdf PDF
Attach I - Sign in Sheet.pdf PDF
IFB 36C25026B0006_1.pdf PDF
Attach V - Appendix D.pdf PDF
Attach VIII - VHA Directive 1192-01.pdf PDF
Attach XI - RFI 610A4-23-101.doc DOC document
Attach I - SOW - 610A4-23-101.pdf PDF
Attach IV - Appendix C.pdf PDF
Attach VI - Drawings Combined 610A4-23-101.pdf PDF
Attach VII - Specs Combined 610A4-23-101.pdf PDF
Attach IX - Wage Determination - Allen County 12.5.25.txt TXT text file
Attach X - VAAR 852.219-75 - 610A4-23-101.pdf PDF
Attach II - Appendix A.pdf PDF
Attach III - Appendix B.pdf PDF
Show all 47

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REQUEST FOR INFORMATION (RFI)

36C25026B0006

PROJECT NUMBER: 610A4-23-101 Please ensure that before submitting questions or requests for clarification that you thoroughly read the solicitation, specifications, drawings and other pertinent documents. When submitting questions on this project the Government requires contractors to specifically identify the specification and/or solicitation section(s) or drawing number(s) in reference to the question or request for clarification submitted. No question or request for clarification will be answered by the Government unless the above requirements are met. Failure to comply may prevent the Government from responding in a timely manner.

PROJECT TITLE: Upgrade Campus Electrical System

PROJECT LOCATION:

VA Northern Indiana Healthcare System 2121 Lake Ave Fort Wayne IN 46805-

TO: Brian Rosciszewski, Contract Specialist

Department of Veterans Affairs Network 10 Contracting Office Brian.Rosciszewski@VA.gov

INFORMATION NEEDED: Write each in the form of a question. Use one document for all questions. Specify any referenced specs/drawings. Submit all questions on one document only to Brian.Rosciszewski@VA.gov.

Subject of the email must be: “RFI – {Solicitation #} – Firm Name”

With regards to Section 26 05 73 Overcurrent Protective Device Coordination Study:

1. Just confirming as a part of this study it is a requirement to provide all low voltage circuit breaker coordination settings & all medium voltage relay settings & files for all equipment regardless of supplier? For example, if one manufacturer provides the medium voltage switchgear MSVG, then will all relay files associated with that switchgear be provided by others as a part of this study?

With regards to Section 26 13 13 Medium Voltage Circuit Breaker Switchgear, 3.2.C (Acceptance Checks & Tests)

2. Is NETA Circuit Breaker Testing required on each individual circuit breaker?

3. Is NETA testing of all main bus required (NETA specified Megger, Hi-Pot, etc)? The spec does require insulation resistance tests on each bus section however need to confirm if entire bus needs tested and if NETA is required.

Government Response: RFI’s will be answered by amendment(s) issued to SAM.gov

Section 26 05 73 OCPD Study Question 1 Answer: All new equipment is included in OCPD study per the specifications.

Section 26 13 13 MV Swgr Question 2 Answer: Yes, please include.

Section 26 13 13 MV Swgr Question 3 Answer: Yes, please include.

MG HEAPY 3/2/26

Contractor Name Contact Info (Phone & Address)

CM Buck & Associates 6850 Guin Rd Indianapolis, IN 46268 mailto:Brian.Rosciszewski@VA.gov

File details come from the government source that posted it. Updated .