Sole Source Justification Siemens Desigo KO signed - 506-20-103.pdf

PDF 240 KB Posted

Attached to
Z1DA--Upgrade Primary Care Building 1E, 506-20-103
Solicitation number
36C25023B0057
Issued by

About this file

This document contains a justification for a single source award and information about a related federal contract opportunity. The justification is for a $200,000 sole source contract with Siemens Desigo to provide, configure, and install a Rauland R5 nurse call system at the VA Ann Arbor Medical Center. The justification cites the proprietary nature of Siemens' programming languages and topography for the existing integrated facility-wide building management system as requiring the single source award.

The related federal contract opportunity is a pre-solicitation notice for project 506-20-103 to upgrade a primary care building at the LTC Charles S. Kettles VAMC in Ann Arbor, MI. The planned IFB has a magnitude of cost between $5-10 million, will have a 550 day period of performance, and is set aside as a total SDVOSB opportunity. The solicitation is expected to be posted on May 27, 2023 on SAM.gov.

View the file

Other files

File Type Posted
Notice of Award Aug 22 - 506-20-103.pdf PDF
Wage Determination MI20230100 July 21 - 506-21-103.pdf PDF
36C25023B0057 0003.pdf PDF
34 AD121 FIRST FLOOR REFLECTED CEILING DEMOLITION PLAN - 506-20-103.pdf PDF
Project Manual Volume 1 Updated through Addendum No 1 - 506-20-103.pdf PDF
AE Addendum 01 Write Up - 506-20-103.pdf PDF
36C25023B0057 0002.pdf PDF
01 GI000 Cover Sheet - 506-20-103.pdf PDF
Pre-Bid Site Visit Agenda signed - 506-20-103.pdf PDF
36C25023B0057 0001.pdf PDF
Pre Bid Site Visit Attendance Log signed - 506-20-103.pdf PDF
Drawings A2 - 506-20-103.pdf PDF
Drawings C - 506-20-103.pdf PDF
Wage Determination MI20230100 Apr 7 - 506-20-103.pdf PDF
Sole Source Justification Simplex KO signed - 506-20-103.pdf PDF
RFI Form - 506-20-103.pdf PDF
Specifications Volume 2 - 506-20-103.pdf PDF
Sole Source Justification Swisslog KO signed - 506-20-103.pdf PDF
Sole Source Justification Rauland R5 KO signed - 506-20-103.pdf PDF
Drawings B - 506-20-103.pdf PDF
Drawings D2 - 506-20-103.pdf PDF
Drawings D1 - 506-20-103.pdf PDF
36C25023B0057_1 cleared - 506-20-103.pdf PDF
EMR Certification Form - 506-20-103.pdf PDF
Specifications Volume 1 - 506-20-103.pdf PDF
Drawings A1 - 506-20-103.pdf PDF
36C25023B0057.docx DOCX document
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ATTACHMENT 4

Justification for Single (Sole) Source Awards to Other Than SDVOSB or VOSB Concerns Over Micro-Purchase Threshold of $2,000 but Not Exceeding $250,000

Acquisition Plan No.: 36C250-23-AP-3265 2237 No.: 506-23-4-586-0040

1. Contracting Activity: Department of Veterans Affairs, VISN 10, VA Ann Arbor Medical Center

2. Brief Description of Supplies/ Services required and the intended use/Estimated Amount:

Scope of Work Statement: Provide, configure, and install Rauland R5 Nurse call System IGCE (For Official Use Only): $200,000

3. Identity of Single Source Company:

Company Name: Siemens Desigo Address: 45470 Commerce Center Drive City: Plymouth Township State: MI Zip: 48170 Phone: 734-456-3900 Point of Contact:

DUNS:

Socio-economic Classification (Small Business, Woman Owned, 8a, HUBZone, Small Disadvantaged Business): NA

4. Unique characteristics that limit availability to only one source, with the reason no other supplies or services can be used (justify why the project needs to be limited to the single source): Facility Standard for integrated facility wide Building management System. Programming, server support, graphical interface are all key elements to this integrated system. Programming languages and topography are proprietary.

5. Description of market research conducted and results or statement why it was not conducted:

The entire facility is under one common and fully integrated Building Management System. Should an alternate provider be allowed, then the full system integration for the facility will be compromised. Key system elements that need to be in place to clean clear integrated controls are as follows:

VA provided web server; VA integration through VA OIT systems for facility wide communications; seamless integration through a single point of control with simplified graphical interface to link all systems and systems components. This is required to be stepped through both existing systems and system elements not being modified under this contract and full integration of new control elements components and sub-systems.

Programming languages need to match Programming topography needs to match Program sequence of control need to be identical All system elements are required to be fully operational through a single platform

6. Contracting Officer's Certification: Single source request is approved. I certify that the foregoing justification is accurate and complete to the best of my knowledge and belief.