Drawings D1 - 506-20-103.pdf
PDF 11 MB Posted
- Solicitation number
- 36C25023B0057
About this file
This document is a pre-solicitation notice for an upcoming invitation for bid from the Department of Veterans Affairs for project 506-20-103 to upgrade a primary care building at the LTC Charles S. Kettles Veterans Administration Medical Center in Ann Arbor, Michigan. The project scope involves internal demolition of the existing primary care area and full reconstruction of a new primary care area. The solicitation is planned for release on May 27, 2023 and will have a bid due date specified therein. The procurement is set aside solely for verified Service-Disabled Veteran Owned Small Businesses and has an estimated value between $5-10 million. The contract type will be firm fixed price with an anticipated award date within 550 days of bid opening. Interested parties should monitor the Contract Opportunities website at www.sam.gov for solicitation details and amendments.
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
J
XX-1
K
D T
S
T
TD
D
EM
P
P
J
R
TC
H
T
F
F
F
F
XX-1 XX-1 XX-1
XX-1
D
F
P
FR
CLNG
J
CLNG
48"
F S
D
V
M
ES
ML
DC
CL
CR
MD
E
B
S
P
N
TV
N
N
TP
1P 1 POLE (2P, 3P, 4P, ETC.)
A AMPERE
AC ABOVE COUNTER
ACLG ABOVE CEILING
ADO AUTOMATIC DOOR OPENER
AF AMP FRAME
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFI ARC FAULT CIRCUIT
INTERRUPTER
AHU AIR HANDLING UNIT
AL ALUMINUM
ALT ALTERNATE
AMP AMPERE
AMPL AMPLIFIER
ANNUN ANNUNCIATOR
APPROX APPROXIMATELY
AQ-STAT AQUASTAT
ARCH ARCHITECT, ARCHITECTURAL
AS AMP SWITCH
AT AMP TRIP
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AUX AUXILIARY
AV AUDIO VISUAL
AWG AMERICAN WIRE GAUGE
BATT BATTERY
BD BOARD
BLDG BUILDING
BMS BUILDING MANAGEMENT SYSTEM
C CONDUIT
CAB CABINET
CAT CATALOG
CATV CABLE TELEVISION
CB CIRCUIT BREAKER
CCTV CLOSED CIRCUIT TELEVISION
CKT CIRCUIT
CLG CEILING
COMB COMBINATION
CMPR COMPRESSOR
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUATION OR
CONTINUOUS
CONTR CONTRACTOR
CONV CONVECTOR
CP CIRCULATING PUMP
CRT CATHODE-RAY TUBE
CT CURRENT TRANSFORMER
CTR CENTER
CU COPPER
DCP DOMESTIC WATER CIRCULATING
PUMP
DEPT DEPARTMENT
DET DETAIL
DIA DIAMETER
DISC DISCONNECT
DIST DISTRIBUTION
DN DOWN
DPR DAMPER
DS SAFETY DISCONNECT SWITCH
DT DOUBLE THROW
DWG DRAWING
EC ELECTRICAL CONTRACTOR
ELEC ELECTRIC, ELECTRICAL
ELEV ELEVATOR
ELU EMERGENCY LIGHTING UNIT
EM EMERGENCY
EMS ENERGY MANAGEMENT SYSTEM
EMT ELECTRICAL METALLIC TUBING
EP ELECTRIC PNEUMATIC
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EXIST EXISTING
EXH EXHAUST
EXP EXPLOSION PROOF
FA FIRE ALARM
FABP FIRE ALARM BOOSTER POWER
SUPPLY PANEL
FACP FIRE ALARM CONTROL PANEL
FCU FAN COIL UNIT
FIXT FIXTURE
FLR FLOOR
FLUOR FLUORESCENT
FU FUSE
FUDS FUSED SAFETY DISCONNECT
SWITCH
GA GAUGE
GAL GALLON
GALV GALVANIZED
GC GENERAL CONTRACTOR
GEN GENERATOR
GFI GROUND FAULT CIRCUIT
INTERRUPTER
GFP GROUND FAULT PROTECTOR
GND GROUND
GRS GALVANIZED RIGID STEEL
(CONDUIT)
GYP BD GYPSUM BOARD
HOA HANDS-OFF-AUTOMATIC SWITCH
HORIZ HORIZONTAL
HP HORSEPOWER
HPF HIGH POWER FACTOR
HT HEIGHT
HTG HEATING
HTR HEATER
HV HIGH VOLTAGE
HVAC HEATING, VENTILATING AND AIR
CONDITIONING
IC INTERRUPTING CAPACITY
IG ISOLATED GROUND
IMC INTERMEDIATE METAL CONDUIT
INCAND INCANDESCENT
IR INFRARED
I/W INTERLOCK WITH
J-BOX JUNCTION BOX
KV KILOVOLT
KVA KILOVOLT-AMPERE
KVAR KILOVOLT-AMPERE REACTIVE
KW KILOWATT
KWH KILOWATT HOUR
LOC LOCATE OR LOCATION
LT LIGHT
LTG LIGHTING
LTNG LIGHTNING
LV LOW VOLTAGE
MAX MAXIMUM
MAG.S MAGNETIC STARTER
M/C MOMENTARY CONTACT
MC MECHANICAL CONTRACTOR
ELECTRICAL ABBREVIATIONS LIST ELECTRICAL SYMBOL NOTES
EXIT LIGHTS. STEM INDICATES WALL MOUNTING. NO STEM INDICATES
CEILING MOUNTING. SHADED AREA INDICATES ILLUMINATED FACE(S).
ARROW INDICATES DIRECTIONAL ARROW ON ILLUMINATED FACE(S).
THE CIRCUIT DESIGNATION IS INDICATED BY A NUMBER. EXAMPLE: THE
WALL MOUNTED EXIT LIGHT TYPE "E1" WITH SINGLE FACE AND
DIRECTIONAL ARROW IS CONNECTED TO CIRCUIT 1.
DEVICES. THE CIRCUIT DESIGNATION IS INDICATED BY A NUMBER.
THE SWITCH
DESIGNATION IS INDICATED BY A LOWER CASE LETTER. EXAMPLE:
SPLIT DUPLEX RECEPTACLE IS CONNECTED TO CIRCUIT 1 AND ONE
RECEPTACLE OUTLET IS CONTROLLED BY SWITCH "d".
THE CONTROL DEVICE DESIGNATION IS INDICATED BY A LOWER CASE
LETTER. EXAMPLE: SINGLE POLE SWITCH "d" TO CONTROL LIGHTING
FIXTURES INDICATED BY "d".
WALL BOX DIMMER WITH SIZE AS INDICATED AT DEVICE. EXAMPLE: 600
WATT WALL BOX DIMMER TO CONTROL LIGHTING FIXTURES INDICATED
BY "e". SEE SPECIFICATIONS FOR WATTAGE IF NOT INDICATED.
SPECIAL CONNECTIONS. THE EQUIPMENT IS INDICATED BY A NUMBER
IN A CIRCLE. SEE THE MOTOR AND EQUIPMENT SCHEDULE FOR THE
LOAD DESCRIPTION AND TYPE OF CONNECTION. THE CIRCUIT
DESIGNATION IS INDICATED BY NUMBER(S) ADJACENT TO THE SYMBOL.
EXAMPLE: EQUIPMENT NO. ELEC-1; 1 PHASE CONNECTION TO
CIRCUITS 2, 4.
MOTOR CONNECTIONS. THE MOTOR IS INDICATED BY A NUMBER
WITHIN OR CHARACTERS ADJACENT TO THE MOTOR SYMBOL. SEE
THE MOTOR AND EQUIPMENT SCHEDULE FOR THE MOTOR
DESCRIPTION AND ELECTRICAL REQUIREMENTS.
TRANSFORMERS. THE TRANSFORMER TYPE IS INDICATED BY A NUMBER
FOLLOWING THE UPPER CASE LETTER "T". SEE THE TRANSFORMER
SCHEDULE OR THE SINGLE LINE DIAGRAM FOR THE TRANSFORMER
DESCRIPTION AND REQUIREMENTS. EXAMPLE: TRANSFORMER TYPE "T1".
PANELBOARDS. PANELBOARD DOORS MAY BE SHOWN TO
INDICATE OPENING SIDE OF RECESSED PANELBOARDS. SEE
PANELBOARD IDENTIFICATION FOR DESIGNATION CODES.
CONDUIT SHOWN WITHOUT SLASH MARKS SHALL CONTAIN 1 # 12
CONDUCTOR PER PHASE, NEUTRAL, AND GROUND IN 1/2" CONDUIT
UNLESS SPECIFIC EQUIPMENT REQUIRES A DIFFERENT SIZE.
CONDUIT SHOWN SHALL CONTAIN 1 # 10 CONDUCTOR PER PHASE IN
ELECTRICAL CODE SIZED MINIMUM CONDUIT UNLESS A CONDUCTOR
AND CONDUIT SIZE IS SHOWN ADJACENT.
HOME RUN TO BRANCH CIRCUIT PANELBOARD. THE PANELBOARD
DESIGNATION IS SHOWN ADJACENT TO THE HOME RUN ARROW AS A
NUMERATOR AND THE CIRCUIT DESIGNATION IS SHOWN AS THE
DENOMINATOR. CIRCUIT BREAKER SIZES (AMPS/NUMBER OF POLES)
ARE SHOWN IN THE PANELBOARD SCHEDULE WITH THE
CORRESPONDING PANELBOARD AND CIRCUIT DESIGNATION.
EXAMPLE: HOME RUN TO PANELBOARD P4N-102; CIRCUITS 1, 3, 5.
SYMBOLSYMBOL SYMBOLDESCRIPTION DESCRIPTION DESCRIPTION
FIRE ALARM HORN W/STROBE
FIRE ALARM BELL
FIRE ALARM BELL W/STROBE
FIRE ALARM CHIME W/STROBE
THERMOSTAT
HUMIDISTAT
TIME CONTROL SWITCH
RELAY
CABLE TAP BOX
SAFETY DISC. SW. (FUSED)
SAFETY DISC. SW. (NON-FUSED)
COMB. MOTOR STARTER (FUSED)
MOTOR
TRANSFORMER
FLOOR JUNCTION BOX
JUNCTION BOX
UTILITY SERVICE POWER POLE
STATIC GROUND RECEPTACLE
SURGERY SERVICE COLUMN
POWER POLE (OPEN OFFICE STYLE)
MULTIOUTLET ASSEMBLY
RECEPTACLE ON CORD REEL
FLOOR DUPLEX RECEPTACLE
240V RECEPTACLE
FOURPLEX RECEPTACLE ON
EMERGENCY CIRCUIT
FOURPLEX RECEPTACLE
DUPLEX RECEPTACLE ON
EMERGENCY CIRCUIT
DUPLEX ISOLATED GROUND RECEPT.
SPLIT DUPLEX RECEPTACLE
DUPLEX RECEPTACLE
SINGLE RECEPTACLE
PUSH BUTTON
TIME DELAY SWITCH
TIMER SWITCH
OCCUPANCY SENSOR W/ MANUAL
SWITCH
DIMMER SWITCH
SWITCH W/PILOT
KEYED SWITCH
4-WAY SWITCH
3-WAY SWITCH
SINGLE POLE SWITCH
BUS DUCT W/ PLUG IN DISCONNECT
PS - D2
T1
PANELBOARD IDENTIFICATION
KEYED NOTE (SEE SCHEDULE)
NUMBER OF SHEET WHERE DETAIL APPEARS
NUMBER OF DETAIL ON SHEET
REVISION NUMBER - SHOWN ON PLANS
ROOM NAME AND NUMBER
DEMOLISHED
ITEM
AREA NOT IN
CONTRACT
XX-1 IDENTITY (SEE SCHEDULE)
XX-1
EXISTING TO REMAIN
XX-1
RELOCATED
XX-1
DEMOLISHED
1d d e
2,4
T1
FLOOR CLEARANCE AREA
CONDUIT IN CEILING, FLOOR OR WALL AS REQUIRED BY FIELD
CONDITIONS
CONDUIT IN FLOOR
P4N-102
1. EQUIPMENT DESIGNATION:
L = LIGHTING
P = POWER
D = DISTRIBUTION
S = SWITCHBOARD
M = MOTOR CONTROL CENTER
R = RELAY PANEL
2. VOLTAGE DESIGNATION:
1 = 120/240V - 1PH
2 = 240V - 3PH
3 = 208Y/120V - 3PH
4 = 480Y/277V - 3PH
5 = 120/208 - 1PH
6 = SPECIAL
3. SYSTEM DESIGNATION:
N = NORMAL
E = EMERGENCY
C = POWER CONDITIONED
U = UNINTERRUPTIBLE POWER SOURCE
4. FLOOR DESIGNATION:
B = BASEMENT
G = GROUND
1 = FIRST FLOOR
2 = SECOND FLOOR
ETC.
5. PANEL NO. DESIGNATION:
01 = PANELBOARD #1
02 = PANELBOARD #2
03 = PANELBOARD #3
ETC.
FIRE ALARM PULL STATION
FIRE ALARM DOOR HOLDER
FIRE ALARM DOOR CLOSER
FIRE ALARM SHUT DOWN RELAY
CEILING DATA OUTLET
FLOOR DATA OUTLET
# OF VOICE AND # OF DATA OUTLETS.
EXAMPLE 1V2D = 1 VOICE, 2 DATA
P4N-102
1, 3, 5
#10
#12
EXISTING TO REMAIN
EXISTING TO BE REMOVED
NEW
GRAPHICAL REPRESENTATION OF PHASING, TYPICAL FOR ALL
SYMBOLS
CEILING DUPLEX RECEPTACLE
CEILING JUNCTION BOX
FLOOR TELEPHONE OUTLET
GFI DUPLEX RECEPTACLE (FEED
THROUGH)
GFI WEATHERPROOF RECEPTACLE
DUPLEX RECEPTACLE
(DESIGNATES SPECIFIC MTG. HT.)
CLNG
ELEC-1
Room
FIRE ALARM SPEAKER W/STROBE
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MDC MAIN DISTRIBUTION CENTER
MDP MAIN DISTRIBUTION PANEL
MFR MANUFACTURER
MFS MAIN FUSED DISCONNECT
SW
MH MANHOLE
MIC MICROPHONE
MIN MINIMUM
MISC MISCELLANEOUS
MLO MAIN LUGS ONLY
MMS MANUAL MOTOR STARTER
MOA MULTIOUTLET ASSEMBLY
MSP MOTOR STARTER
PANELBOARD
MSBD MAIN SWITCHBOARD
MT MOUNT
MT.C EMPTY CONDUIT
MTS MANUAL TRANSFER SWITCH
MTR MOTOR, MOTORIZED
N.C. NORMALLY CLOSED
NEC NATIONAL ELECTRICAL CODE
NEMA NATIONAL ELECTRICAL
MANUFACTURER'S
ASSOCIATION
NFDS NON-FUSED SAFETY
DISCONNECT SWITCH
NIC NOT IN CONTRACT
NL NIGHT LIGHT
N.O. NORMALLY OPEN
NPF NORMAL POWER FACTOR
NTS NOT TO SCALE
OH OVERHEAD
OL OVERLOADS
PA PUBLIC ADDRESS
PB PULL BOX OR PUSHBUTTON
PE PNEUMATIC ELECTRIC
PED PEDESTAL
PF POWER FACTOR
PH PHASE
PIV POST INDICATING VALVE
PNL PANEL
PP POWER POLE
PR PAIR
PRI PRIMARY
PROJ PROJECTION
PRV POWER ROOF VENTILATOR
PT POTENTIAL TRANSFORMER
PVC POLYVINYL CHLORIDE
(CONDUIT)
PWR POWER
QUAN QUANTITY
RCPT RECEPTACLE
REQD REQUIRED
RM ROOM
RSC RIGID STEEL CONDUIT
RTU ROOF TOP UNIT
SC SURFACE CONDUIT
SEC SECONDARY
SHT SHEET
SIM SIMILAR
S/N SOLID NEUTRAL
SPEC SPECIFICATION
SPKR SPEAKER
SP SPARE
SR SURFACE RACEWAY
SS STAINLESS STEEL
SSW SELECTOR SWITCH
S/S STOP/START PUSHBUTTONS
STA STATION
STD STANDARD
SURF SURFACE MOUNTED
SW SWITCH
SWBD SWITCHBOARD
SYM SYMMETRICAL
SYS SYSTEM
TEL TELEPHONE
TEL/DAT TELEPHONE/DATA
TERM TERMINAL
TL TWIST LOCK
TP TAMPER PROOF
T-STAT THERMOSTAT
TTC TELEPHONE TERMINAL
CABINET
TV TELEVISION
TVTC TELEVISION TERMINAL
CABINET
TYP TYPICAL
UC UNDER COUNTER
UE UNDERGROUND ELECTRICAL
UG UNDERGROUND
UH UNIT HEATER
UT UNDERGROUND TELEPHONE
UTIL UTILITY
UV ULTRAVIOLET
V VOLT
VA VOLT-AMPERES
VDT VIDEO DISPLAY TERMINAL
VERT VERTICAL
VFD VARIABLE FREQUENCY DRIVE
VOL VOLUME
W WATT
W/ WITH
WG WIRE GUARD
WH WATER HEATER
W/O WITHOUT
WP WEATHERPROOF
XFMR TRANSFORMER
XFR TRANSFER
∠ ANGLE
@ AT
▲ DELTA
' FEET
" INCHES
# NUMBER
Ø PHASE
C CENTER LINE
P PLATE
EXIT LIGHT, WALL-MOUNTED,
SHADING AND ARROWS INDICATE
FACES AND DIRECTION
WALL-MOUNTED FIXTURES, TYPICAL
EXW1
LIGHTING FIXTURE TAG DESCRIPTORS:
TOP VALUE: FIXTURE TYPE ID.
BOTTOM VALUE, NUMBER: CIRCUIT NUMBER, REFER TO
DRAWINGS FOR PANEL.
BOTTOM VALUE, LOWERCASE LETTER: SWITCH DESIGNATION.
ABSENCE OF A SWITCH ID INDICATES FIXTURE IS CONTROLLED BY THE
ONLY SWITCH IN THE SPACE.
"x" IN PLACE OF THE SWITCH ID INDICATES NIGHT LIGHT, UNSWITCHED.
S3
1d
ELECTRIC STRIKE
MAGNETIC LOCK
COMBINATION LOCK
DOOR CONTACT
CARD READER
SECURITY KEYPAD
MOTION DETECTOR
NURSE CALL EMERG. STATION
NURSE CALL CODE BLUE STATION
NURSE CALL STAFF STATION
NURSE CALL PATIENT STATION
NURSE CALL DOME LIGHT
(1-COLOR)
TELEPHONE OUTLET
VOICE/DATA OUTLET
DOOR BELL
DOOR BUZZER
DOOR CHIME
DOOR SIGNAL
VOLUME CONTROL
MICROPHONE OUTLET
1V2D
CATV OUTLET
TV OUTLET
NURSE CALL DOME LIGHT
(4-COLORS)
NURSE CALL DOME LIGHT
(2-COLORS)
AUTO DOOR PUSH PAD
EMERGENCY LIGHTING UNIT, WALL-
MOUNTED, REMOTE BATTERY
EMERGENCY LIGHTING UNIT, WALL-
MOUNTED, INTEGRAL BATTERY
EMERGENCY LIGHTING UNIT, CEILING-
MOUNTED, INTEGRAL BATTERY
EMERGENCY LIGHTING UNIT, CEILING-
MOUNTED, REMOTE BATTERY
LIGHTING FIXTURES, TYPICAL,
RECTANGULAR FILLED CIRCLES
INDICATE RECESSED, OPEN CIRCLES
INDICATE SURFACE
DIAGONAL LINE INDICATES LENSED
OUTER DOTS INDICATE SUSPENDED
LIGHTING FIXTURES, TYPICAL, ROUND
CENTER DOT INDICATES PENDANT
DIAGONAL LINE INDICATES LENSED
CHEVRON INDICATES WALL WASH
STRIP FIXTURE
DIRECTIONAL LIGHT, TRACK, FLOOD
EXIT LIGHT, CEILING-MOUNTED,
SHADING AND ARROWS INDICATE
FACES AND DIRECTION
LINEAR LIGHT, TAPE LIGHT
EXIT/ELU COMBO
DIAGONAL HATCH INDICATES LIGHT
ON A CRITICAL CIRCUIT
SOLID HATCH INDICATES LIGHT ON
AN EMERGENCY OR LIFE SAFETY
CIRCUIT
POLE/AREA LIGHTS
POST-TOP AREA LIGHT
BOLLARD LIGHT
SPRINKLER FLOW SWITCH
SPRINKLER VALVE TAMPER SWITCH
DUCT SMOKE DETECTOR
CEILING SMOKE DETECTOR
THERMAL DETECTOR
ELECTRICAL SYMBOL LEGEND
# OF COLORS.
* NOTE *
ALL GENERAL NOTES ON THIS SHEET ARE TO BE APPLIED TO ALL OTHER DRAWINGS
IN THIS SET. THE SYMBOLS AND ABBREVIATIONS SHOWN ON THIS SHEET MAY OR
MAY NOT BE USED IN THIS SET OF DRAWINGS.
EM
G
FI
G
FI
W P
U
SB DUPLEX RECEPTACLE W/ USB PORTS
TP
TAMPER-PROOF DUPLEX
RECEPTACLE
GENERAL PROJECT NOTES
A CONDUCTORS OPERATING AT 50 VOLTS OR GREATER SHALL BE IN RACEWAY.
RACEWAY WITHIN THE STRUCTURE ABOVE THE FLOOR SLAB SHALL BE METAL.
RACEWAY BELOW THE FLOOR SLAB AND UNDERGROUND RACEWAY OUTSIDE
THE STRUCTURE SHALL BE PVC.
B LOW VOLTAGE CABLES OR CONDUCTORS OPERATING AT LESS THAN 50 VOLTS
SHALL BE IN METAL RACEWAY WHERE INSTALLED WITHIN WALLS OR INACCESSIBLE
SPACES. LOW VOLTAGE CABLES MAY BE RUN IN CABLE TRAY WHERE NOTED.
LOW VOLTAGE CABLES MAY BE RUN IN CABLE SUPPORT HOOKS ABOVE
ACCESSIBLE CEILINGS WHERE NOTED. LOW VOLTAGE CABLE SHALL BE PLENUM
RATED IN PLENUM SPACES.
C COORDINATE LOCATIONS OF DEVICES WITH ARCHITECTURAL ELEVATIONS AND
DETAILS. ARCHITECTURAL ELEVATIONS AND DETAILS TAKE PRECEDENCE OVER
LOCATIONS SHOWN ON ELECTRICAL DRAWINGS.
D PROVIDE CABLE OR CONDUIT AND WIRE AS REQUIRED TO ACHIEVE CIRCUITING
SHOWN. SIZE CONDUCTORS PER NEC AMPACITY AND WIRE FILL CRITERIA.
PROVIDE DEDICATED NEUTRAL AND GROUND CONDUCTORS FOR CIRCUITING,
UNLESS NOTED OTHERWISE. INCREASE BRANCH CIRCUIT AND/OR FEEDER
CONDUCTORS INCLUDING EQUIPMENT GROUNDING CONDUCTORS
PROPORTIONALLY FOR NO MORE THAN 3% VOLTAGE DROP ON BRANCH
CIRCUITS AND 2% ON FEEDERS.
E IT IS THE RESPONSIBILITY OF THIS CONTRACTOR TO COORDINATE INSTALLATION
OF ELECTRICAL SYSTEMS AND THOSE REQUIRING ELECTRICAL CONNECTIONS TO
MAINTAIN NEC REQUIRED CLEARANCES, INCLUDED BY NOT LIMITED TO AREAS
ABOVE ACCESSIBLE CEILINGS.
F COORDINATE WITH OTHER TRADES FOR PROPER INSTALLATION OF ELECTRICAL
EQUIPMENT. CONSULT THE DRAWINGS OF OTHER TRADES OR CRAFTS TO AVOID
CONFLICTS WITH EQUIPMENT, ETC. CONFLICTS SHALL BE RESOLVED PRIOR TO
ROUGH-IN AND AT NO ADDITIONAL COST TO THE OWNER.
G LEAVE THE SITE CLEAN AND READY FOR OCCUPANCY. REMOVE DIRT, DEBRIS,
EMPTY CARTONS, TOOLS, CONDUIT AND WIRE SCRAPS AND MISCELLANEOUS
SPARE EQUIPMENT AND MATERIALS USED IN THIS DIVISION OF THE WORK DURING
CONSTRUCTION. COMPONENTS SHALL BE FREE OF DUST, GRIT AND FOREIGN
MATERIALS AND LEFT AS NEW BEFORE FINAL ACCEPTANCE OF WORK.
H THE SYMBOLS AND ABBREVIATIONS SHOWN ON THIS SHEET MAY OR MAY NOT BE
USED IN THIS SET OF DRAWINGS.
I PERFORM WORK TO COMPLY WITH THE STANDARD PRACTICES FOR GOOD
WORKMANSHIP PUBLISHED BY NATIONAL ELECTRICAL CONTRACTORS
ASSOCIATION (NECA). COMPLY WITH THE LATEST ENFORCED EDITION OF THE
NATIONAL ELECTRICAL CODE (NEC), LOCAL CODES, AMENDMENTS, AND
ORDINANCES.
J FIELD COORDINATE FINAL MECHANICAL AND EQUIPMENT LOCATIONS ALONG
WITH CONNECTION REQUIREMENTS AND CONTROL WIRING PRIOR TO
ROUGH-IN. ADJUST CORRESPONDING CIRCUIT BREAKER RATINGS AND BRANCH
CIRCUITING ACCORDINGLY.
K ELECTRICAL WORK SHALL BE PERFORMED UNDER THE SUPERVISION OF A
LICENSED MASTER ELECTRICIAN. PROCURE PERMITS AND LICENSES AND PAY FEES
ASSOCIATED WITH THIS WORK.
L MATERIALS FURNISHED FOR THIS PROJECT SHALL BE NEW, COMMERCIAL GRADE,
FREE OF DEFECTS, AND LISTED BY A NATIONALLY RECOGNIZED TESTING
LABORATORY UNO.
M PROVIDE COMPLETE OPERATION & MAINTENANCE MANUAL INCLUDING
APPROVED SUBMITTAL DRAWINGS, WARRANTY INFORMATION FOR PRODUCT
SUPPLIED, AND MANUFACTURES OPERATION AND MAINTENANCE INSTRUCTIONS.
N THE CONTRACTOR IS RESPONSIBLE FOR MAKING FINAL WIRING TERMINATIONS
TO PRE-INSTALLED RECEPTACLES IN OFFICE FURNITURE. CONTRACTOR IS
RESPONSIBLE FOR WIRING AND INSTALLING VOICE/DATA DEVICES IN OFFICE
FURNITURE. COORDINATE PLACEMENT OF DEVICES WITH FURNITURE LAY-OUT.
O CONDUIT AND WIRE SHALL NOT BE INSTALLED BELOW FLOOR SLAB UNLESS
INDICATED ON PLAN BY DASHED CONDUIT.
P CONTRACTOR SHALL BE RESPONSIBLE FOR WIRING ELECTRICAL ITEMS SHOWN
ON DRAWINGS.
Q TV OUTLETS, VOLUME CONTROLS, NURSE CALL DOME LIGHTS, NURSE CALL
DEVICES, TELEPHONE OUTLETS, DATA OUTLETS, AND FIRE ALARM DEVICES SHALL
CONSIST OF A DATA DEVICE BACK BOX WTIH CONDUIT STUBBED ABOVE THE
ACCESSIBLE CEILING, SEE STUB UP DETAIL.VERIFY SIZE OF BACK BOX REQUIRED
WITH DEVICE TO BE INSTALLED. LOCATE BACK BOXES 6" FROM ADJACENT
POWER RECEPTACLE INTENDED FOR COMPUTER USE. COORDINATE BOX
REQUIREMENTS INCLUDING SIZE, LOCATION AND CONDUIT SIZE, ROUTE AND
TERMINATION LOCATION WITH THE EQUIPMENT SUPPLIER PRIOR TO ROUGHING
IN. COORDINATE CIRCUITRY/WIRE/CABLE REQUIREMENTS WITH THE RESPECTIVE
EQUIPMENT SUPPLIER/SPECIFIER.
R FURNISH AND INSTALL CONDUIT FROM BACK BOXES FOR THE FOLLOWING
DEVICES INTO THE ACCESSIBLE CEILING SPACE IN THE CORRIDOR, UNLESS NOTED
OTHERWISE:
1 / 2 " C T V O U T L E T S 1 / 2 " C V O L U M E C O N T R O L S
3/4"C DOOR SECURITY DEVICES (CARD READERS, DOOR STRIKES ETC..)
1 / 2 " C N U R S E C A L L D O M E L I G H T S 3 / 4 " C N U R S E C A L L D E V I C E S 3 / 4 " C T E L E P H O N E O U T L E T S 3 / 4 " C I N F O R M A T I O N O U T L E T S 3 / 4 " C F I R E A L A R M D E V I C E S
B R A D E N
S .
C O X
6201070323
NO.
ENGINEER
S T
A
T E
O F M I C
H I
G A
N
R E
E N
I G
N
E L
ANOISSEFORP
D
E S
N E
C I
L
AREA - A
AREA - B
AREA - C
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
DWG. ___ OF 145
7GAE PROJECT NO.: 219123
Sprinkler:
600 E. Michigan Avenue, Suite B
Kalamazoo, MI 49007
P: 269.927.0144 www.7GenAE.com
2850 Eisenhower Ave, Suite 310
Alexandria, VA 22314
P: 202.617.8485 www.alliance.us.com
100% BID DOCUMENTS APRIL 6, 2023
ELECTRICAL GENERAL INFO. &
SYMBOLS LEGEND
UPGRADE PRIMARY CARE
ANN ARBOR VAMC
506-20-103
1E
PROJECT DIRECTOR
APRIL 6, 2023 BC RM
100% BID
DOCUMENTS
E001
FULLY SPRINKLERED
GENERAL FIRE PROTECTION NOTES
A PENETRATIONS IN WALLS REQUIRING PROTECTED OPENINGS MUST BE
FIRESTOPPED WITH AN APPROVED MATERIAL.
B CONDUITS MAY PENETRATE WALLS OR PARTITIONS, PROVIDED THEY ARE
FIRESTOPPED.
C OPENINGS FOR STEEL ELECTRICAL BOXES NOT EXCEEDING 16 SQUARE INCHES
ARE PERMITTED PROVIDED OPENINGS DO NOT AGGREGATE MORE THAN 100
SQUARE INCHES FOR ANY 100 SQUARE FEET OF WALL OR PARTITION.
D OUTLET BOXES ON OPPOSITE SIDES OF WALLS OR PARTITIONS MUST BE
SEPARATED BY A HORIZONTAL DISTANCE OF 24 INCHES.
E LIGHT FIXTURES AND OTHER APPARATUS SUPPORTED BY THE ACOUSTICAL
CEILING GRID MUST MEET THE REQUIREMENTS OF NEC SECTION 410.16, MEANS
OF SUPPORT.
F RECESSED LIGHTING FIXTURES INSTALLED IN FIRE RATED CEILING ASSEMBLIES
SHALL BE FIRE RATED FIXTURES BEARING THE UL FIRE RATED LABEL. FIXTURES SHALL
BE INSTALLED IN ACCORDANCE WITH THE UL FIRE RESISTANCE DIRECTORY, AND
SHALL INCLUDE A FIRE RATED ENCLOSURE INSTALLED OVER THE FIXTURE THAT
MEETS THE REQUIREMENTS OF THE UL FIRE RESISTANCE DIRECTORY.
Revisions: Date:
4/7/23
1E-K
1E-J
1E-J
1E-H
1E-H
1E-G
1E-G
1E-F
1E-F
1E-E
1E-E
1E-10 1E-10
1E-9 1E-9
1E-8 1E-8
1E-7 1E-7
1E-6 1E-6
1E-5 1E-5
1E-4 1E-4
1E-3.8 1E-3.8
1E-3.6 1E-3.6
1E-3.5 1E-3.5
1E-3.4 1E-3.4 1E-3.3
1E-3.3
1E-3 1E-3
S
2 3
2 3
2 3
2 3
2 3
2 3
2 3
2 3
2 3 2 3 2 3 2 3
2 3 2 3
2 3
2 3 2 3 2 3
2 3 2 3 2 3
2 3
2 3
2 3
2 3 3
2 3
2 3 2 3
2 3
2 3
32 32
32 32
32 32
32 32 2 3
2 3
2 3
2 3
2 3
2 3
2 3
2 3
2 3
2 3
(E) 1-AH-9
B R A D E N
S .
C O X
6201070323
NO.
ENGINEER
S T
A
T E
O F M I C
H I
G A
N
R E
E N
I G
N
E L
ANOISSEFORP
D
E S
N E
C I
L
AREA - A
AREA - B
AREA - C
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
DWG. ___ OF 145
7GAE PROJECT NO.: 219123
Sprinkler:
600 E. Michigan Avenue, Suite B
Kalamazoo, MI 49007
P: 269.927.0144 www.7GenAE.com
2850 Eisenhower Ave, Suite 310
Alexandria, VA 22314
P: 202.617.8485 www.alliance.us.com
100% BID DOCUMENTS APRIL 6, 2023
FIRST FLOOR ELECTRICAL
DEMOLITION PLAN
UPGRADE PRIMARY CARE
ANN ARBOR VAMC
506-20-103
1E
PROJECT DIRECTOR
APRIL 6, 2023 BC RM
100% BID
DOCUMENTS
ED101
FULLY SPRINKLERED
GENERAL ELEC. DEMO NOTES
A SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR
PHASES OF DEMOLITION AND CONSTRUCTION. COORDINATE
WITH GENERAL CONSTRUCTION.
B DISCONNECT AND REMOVE ALL ELECTRICAL DEVICES AND
LIGHTING FIXTURES, WHETHER SHOWN OR NOT, IN DEMOLITION
AREAS UNLESS NOTED OTHERWISE.
C DISCONNECT AND REMOVE ALL ELECTRICAL DEVICES IN WALLS
TO BE DEMOLISHED. WALLS TO BE DEMOLISHED ARE SHOWN
DASHED. DISCONNECT AND REMOVE ASSOCIATED CONDUIT
AND WIRE BACK TO LAST REMAINING DEVICE. FURNISH AND
INSTALL CONDUIT AND WIRE AS NECESSARY FOR CONTINUITY OF
CIRCUIT(S) TO ANY EXISTING DEVICES TO REMAIN. COORDINATE
AND VERIFY REQUIREMENTS WITH NEW WORK IN AREA.
D FURNISH AND INSTALL CONDUIT AND WIRE AS NECESSARY FOR
CONTINUITY OF ANY FEEDERS OR BRANCH CIRCUITS
ORIGINATING OUTSIDE THE DEMOLITION AREA THAT SERVES ANY
ELECTRICAL EQUIPMENT OR DEVICES TO REMAIN AFTER
DEMOLITION. MODIFY OR REPLACE AS REQUIRED.
E FURNISH AND INSTALL CONDUIT AND/OR
COMMUNICATIONS/DATA WIRING AS NECESSARY FOR
CONTINUITY OF ANY WIRING ORIGINATING OUTSIDE THE
DEMOLITION AREA THAT SERVES ANY COMMUNICATIONS/DATA
EQUIPMENT OR DEVICES TO REMAIN AFTER DEMOLITION.
MODIFY OR REPLACE AS REQUIRED.
F DISCONNECT AND REMOVE LIGHT SWITCHES IN DEMOLITION
AREAS AS NECESSARY TO ACCOMMODATE NEW DOOR
CONFIGURATIONS.
G DISCONNECT AND REMOVE ANY EXISTING ELECTRICAL DEVICES
AND BACK BOXES AS NECESSARY WHERE NEW WALL
CONSTRUCTION WILL INTERSECT AN EXISTING WALL. FURNISH
AND INSTALL CONDUIT AND WIRE AS REQUIRED FOR
CONTINUITY OF CIRCUIT(S).
H FURNISH AND INSTALL BLANK COVER PLATES OVER ALL EXISTING
UNUSED OPENINGS.
NORTH
SCALE: 1/8" = 1'-0"
FIRST FLOOR ELECTRICAL DEMOLITION PLAN
KEYNOTES
1 EXISTING RECEPTACLE SHALL REMAIN, REFER TO THE POWER
PLAN FOR THE NEW/REVISED CIRCUITING INFORMATION.
2 DEMOLISH LIGHT FIXTURES, SWITCHES AND ASSOCIATED
UNUSED BRANCH CIRCUITRY, FIELD VERIFY QUANTITIES AND
REQUIREMENTS.
3 DEMOLISH RECEPTACLES AND ELECTRICAL DEVICES, UNLESS
NOTED OTHERWISE, AND ASSOCIATED UNUSED BRANCH
CIRCUITRY, FIELD VERIFY QUANTITIES AND REQUIREMENTS.
4 DEMOLISH POWER, ASSOCIATED CIRCUITRY AND CONTROL
CABLING FOR THE LIFT DEMOLITION. FIELD VERIFY THE
REQUIREMENTS.
5 FIELD VERIFY THE LOCATION AND DEMOLISH THE EXISTING
DISCONNECT SERVING THE EXISTING FAN IN AHU-9. DEMOLISH
THE ASSOCIATED CONDUIT AND WIRING BACK TO THE
SOURCE. DEMOLISH THE ASSOCIATED CIRCUIT BREAKER, THE
SPACE SHALL BE REUSED FOR THE NEW FAN, SF-9, CIRCUIT
BREAKER.
1E-J
1E-J
1E-H
1E-H
1E-G
1E-G
1E-F
1E-F
1E-E
1E-E
1E-5 1E-5
1E-4 1E-4
1E-3.8 1E-3.8
1E-3.6 1E-3.6
1E-3.5 1E-3.5
1E-3.4 1E-3.4
1E-3.3 1E-3.3
1E-3 1E-3
S
1 DEMOLISHED
RECEPTACLE,
TYPICAL
DEMOLISHED
LIGHT FIXTURE,
TYPICAL
2 3
2 3
2 3
2 3
2 3
2 3
2 3
2 32 32
2 3
2 3 2 3
2 3
B R A D E N
S .
C O X
6201070323
NO.
ENGINEER
S T
A
T E
O F M I C
H I
G A
N
R E
E N
I G
N
E L
ANOISSEFORP
D
E S
N E
C I
L
AREA - A
AREA - B
AREA - C
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
DWG. ___ OF 145
7GAE PROJECT NO.: 219123
Sprinkler:
600 E. Michigan Avenue, Suite B
Kalamazoo, MI 49007
P: 269.927.0144 www.7GenAE.com
2850 Eisenhower Ave, Suite 310
Alexandria, VA 22314
P: 202.617.8485 www.alliance.us.com
100% BID DOCUMENTS APRIL 6, 2023
ENLARGED ELECTRICAL
DEMOLITION PLAN - AREA A
UPGRADE PRIMARY CARE
ANN ARBOR VAMC
506-20-103
1E
PROJECT DIRECTOR
APRIL 6, 2023 BC RM
100% BID
DOCUMENTS
ED101A
FULLY SPRINKLERED
NORTH
SCALE: 1/4" = 1'-0"
ENLARGED ELECTRICAL DEMOLITION PLAN - AREA A
GENERAL ELEC. DEMO NOTES
A SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR
PHASES OF DEMOLITION AND CONSTRUCTION. COORDINATE
WITH GENERAL CONSTRUCTION.
B DISCONNECT AND REMOVE ALL ELECTRICAL DEVICES AND
LIGHTING FIXTURES, WHETHER SHOWN OR NOT, IN DEMOLITION
AREAS UNLESS NOTED OTHERWISE.
C DISCONNECT AND REMOVE ALL ELECTRICAL DEVICES IN WALLS
TO BE DEMOLISHED. WALLS TO BE DEMOLISHED ARE SHOWN
DASHED. DISCONNECT AND REMOVE ASSOCIATED CONDUIT
AND WIRE BACK TO LAST REMAINING DEVICE. FURNISH AND
INSTALL CONDUIT AND WIRE AS NECESSARY FOR CONTINUITY OF
CIRCUIT(S) TO ANY EXISTING DEVICES TO REMAIN. COORDINATE
AND VERIFY REQUIREMENTS WITH NEW WORK IN AREA.
D FURNISH AND INSTALL CONDUIT AND WIRE AS NECESSARY FOR
CONTINUITY OF ANY FEEDERS OR BRANCH CIRCUITS
ORIGINATING OUTSIDE THE DEMOLITION AREA THAT SERVES ANY
ELECTRICAL EQUIPMENT OR DEVICES TO REMAIN AFTER
DEMOLITION. MODIFY OR REPLACE AS REQUIRED.
E FURNISH AND INSTALL CONDUIT AND/OR
COMMUNICATIONS/DATA WIRING AS NECESSARY FOR
CONTINUITY OF ANY WIRING ORIGINATING OUTSIDE THE
DEMOLITION AREA THAT SERVES ANY COMMUNICATIONS/DATA
EQUIPMENT OR DEVICES TO REMAIN AFTER DEMOLITION.
MODIFY OR REPLACE AS REQUIRED.
F DISCONNECT AND REMOVE LIGHT SWITCHES IN DEMOLITION
AREAS AS NECESSARY TO ACCOMMODATE NEW DOOR
CONFIGURATIONS.
G DISCONNECT AND REMOVE ANY EXISTING ELECTRICAL DEVICES
AND BACK BOXES AS NECESSARY WHERE NEW WALL
CONSTRUCTION WILL INTERSECT AN EXISTING WALL. FURNISH
AND INSTALL CONDUIT AND WIRE AS REQUIRED FOR
CONTINUITY OF CIRCUIT(S).
H FURNISH AND INSTALL BLANK COVER PLATES OVER ALL EXISTING
UNUSED OPENINGS.
KEYNOTES
1 EXISTING RECEPTACLE SHALL REMAIN, REFER TO THE POWER
PLAN FOR THE NEW/REVISED CIRCUITING INFORMATION.
2 DEMOLISH LIGHT FIXTURES, SWITCHES AND ASSOCIATED
UNUSED BRANCH CIRCUITRY, FIELD VERIFY QUANTITIES AND
REQUIREMENTS.
3 DEMOLISH RECEPTACLES AND ELECTRICAL DEVICES, UNLESS
NOTED OTHERWISE, AND ASSOCIATED UNUSED BRANCH
CIRCUITRY, FIELD VERIFY QUANTITIES AND REQUIREMENTS.
4 DEMOLISH POWER, ASSOCIATED CIRCUITRY AND CONTROL
CABLING FOR THE LIFT DEMOLITION. FIELD VERIFY THE
REQUIREMENTS.
1E-J
1E-J
1E-H
1E-H
1E-G
1E-G
1E-F
1E-F
1E-E
1E-E
1E-7 1E-7
1E-6 1E-6
1E-5 1E-5
S
DEMOLISHED
RECEPTACLE,
TYPICAL
DEMOLISHED
LIGHT FIXTURE,
TYPICAL
2 3
2 3
2 32 32
2 3 2 3
2 3
2 3
2 3
2 3
2 3
2 3 2 3
2 32 3
2 3
2 3 2 3
2 3
2 3 2 3
2 3
2 3 2 3
2 3
2 3
2 3
2 3
2 3
2 3
2 3
2 3
2 3
2 3
B R A D E N
S .
C O X
6201070323
NO.
ENGINEER
S T
A
T E
O F M I C
H I
G A
N
R E
E N
I G
N
E L
ANOISSEFORP
D
E S
N E
C I
L
AREA - A
AREA - B
AREA - C
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
DWG. ___ OF 145
7GAE PROJECT NO.: 219123
Sprinkler:
600 E. Michigan Avenue, Suite B
Kalamazoo, MI 49007
P: 269.927.0144 www.7GenAE.com
2850 Eisenhower Ave, Suite 310
Alexandria, VA 22314
P: 202.617.8485 www.alliance.us.com
100% BID DOCUMENTS APRIL 6, 2023
ENLARGED ELECTRICAL
DEMOLITION PLAN - AREA B
UPGRADE PRIMARY CARE
ANN ARBOR VAMC
506-20-103
1E
PROJECT DIRECTOR
APRIL 6, 2023 BC RM
100% BID
DOCUMENTS
ED101B
FULLY SPRINKLERED
NORTH
SCALE: 1/4" = 1'-0"
ENLARGED ELECTRICAL DEMOLITION PLAN - AREA B
GENERAL ELEC. DEMO NOTES
A SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR
PHASES OF DEMOLITION AND CONSTRUCTION. COORDINATE
WITH GENERAL CONSTRUCTION.
B DISCONNECT AND REMOVE ALL ELECTRICAL DEVICES AND
LIGHTING FIXTURES, WHETHER SHOWN OR NOT, IN DEMOLITION
AREAS UNLESS NOTED OTHERWISE.
C DISCONNECT AND REMOVE ALL ELECTRICAL DEVICES IN WALLS
TO BE DEMOLISHED. WALLS TO BE DEMOLISHED ARE SHOWN
DASHED. DISCONNECT AND REMOVE ASSOCIATED CONDUIT
AND WIRE BACK TO LAST REMAINING DEVICE. FURNISH AND
INSTALL CONDUIT AND WIRE AS NECESSARY FOR CONTINUITY OF
CIRCUIT(S) TO ANY EXISTING DEVICES TO REMAIN. COORDINATE
AND VERIFY REQUIREMENTS WITH NEW WORK IN AREA.
D FURNISH AND INSTALL CONDUIT AND WIRE AS NECESSARY FOR
CONTINUITY OF ANY FEEDERS OR BRANCH CIRCUITS
ORIGINATING OUTSIDE THE DEMOLITION AREA THAT SERVES ANY
ELECTRICAL EQUIPMENT OR DEVICES TO REMAIN AFTER
DEMOLITION. MODIFY OR REPLACE AS REQUIRED.
E FURNISH AND INSTALL CONDUIT AND/OR
COMMUNICATIONS/DATA WIRING AS NECESSARY FOR
CONTINUITY OF ANY WIRING ORIGINATING OUTSIDE THE
DEMOLITION AREA THAT SERVES ANY COMMUNICATIONS/DATA
EQUIPMENT OR DEVICES TO REMAIN AFTER DEMOLITION.
MODIFY OR REPLACE AS REQUIRED.
F DISCONNECT AND REMOVE LIGHT SWITCHES IN DEMOLITION
AREAS AS NECESSARY TO ACCOMMODATE NEW DOOR
CONFIGURATIONS.
G DISCONNECT AND REMOVE ANY EXISTING ELECTRICAL DEVICES
AND BACK BOXES AS NECESSARY WHERE NEW WALL
CONSTRUCTION WILL INTERSECT AN EXISTING WALL. FURNISH
AND INSTALL CONDUIT AND WIRE AS REQUIRED FOR
CONTINUITY OF CIRCUIT(S).
H FURNISH AND INSTALL BLANK COVER PLATES OVER ALL EXISTING
UNUSED OPENINGS.
KEYNOTES
1 EXISTING RECEPTACLE SHALL REMAIN, REFER TO THE POWER
PLAN FOR THE NEW/REVISED CIRCUITING INFORMATION.
2 DEMOLISH LIGHT FIXTURES, SWITCHES AND ASSOCIATED
UNUSED BRANCH CIRCUITRY, FIELD VERIFY QUANTITIES AND
REQUIREMENTS.
3 DEMOLISH RECEPTACLES AND ELECTRICAL DEVICES, UNLESS
NOTED OTHERWISE, AND ASSOCIATED UNUSED BRANCH
CIRCUITRY, FIELD VERIFY QUANTITIES AND REQUIREMENTS.
1E-J
1E-J
1E-H
1E-H
1E-G
1E-G
1E-F
1E-F
1E-E
1E-E
1E-11 1E-11
1E-10 1E-10
1E-9 1E-9
1E-8 1E-8
1E-7 1E-7
S
DEMOLISHED
LIGHT FIXTURE,
TYPICAL
DEMOLISHED
RECEPTACLE,
TYPICAL
1 2 1 2
1 2
1 2
B R A D E N
S .
C O X
6201070323
NO.
ENGINEER
S T
A
T E
O F M I C
H I
G A
N
R E
E N
I G
N
E L
ANOISSEFORP
D
E S
N E
C I
L
AREA - A
AREA - B
AREA - C
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
DWG. ___ OF 145
7GAE PROJECT NO.: 219123
Sprinkler:
600 E. Michigan Avenue, Suite B
Kalamazoo, MI 49007
P: 269.927.0144 www.7GenAE.com
2850 Eisenhower Ave, Suite 310
Alexandria, VA 22314
P: 202.617.8485 www.alliance.us.com
100% BID DOCUMENTS APRIL 6, 2023
ENLARGED ELECTRICAL
DEMOLITION PLAN - AREA C
UPGRADE PRIMARY CARE
ANN ARBOR VAMC
506-20-103
1E
PROJECT DIRECTOR
APRIL 6, 2023 BC RM
100% BID
DOCUMENTS
ED101C
FULLY SPRINKLERED
NORTH
SCALE: 1/4" = 1'-0"
ENLARGED ELECTRICAL DEMOLITION PLAN - AREA C
GENERAL ELEC. DEMO NOTES
A SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR
PHASES OF DEMOLITION AND CONSTRUCTION. COORDINATE
WITH GENERAL CONSTRUCTION.
B DISCONNECT AND REMOVE ALL ELECTRICAL DEVICES AND
LIGHTING FIXTURES, WHETHER SHOWN OR NOT, IN DEMOLITION
AREAS UNLESS NOTED OTHERWISE.
C DISCONNECT AND REMOVE ALL ELECTRICAL DEVICES IN WALLS
TO BE DEMOLISHED. WALLS TO BE DEMOLISHED ARE SHOWN
DASHED. DISCONNECT AND REMOVE ASSOCIATED CONDUIT
AND WIRE BACK TO LAST REMAINING DEVICE. FURNISH AND
INSTALL CONDUIT AND WIRE AS NECESSARY FOR CONTINUITY OF
CIRCUIT(S) TO ANY EXISTING DEVICES TO REMAIN. COORDINATE
AND VERIFY REQUIREMENTS WITH NEW WORK IN AREA.
D FURNISH AND INSTALL CONDUIT AND WIRE AS NECESSARY FOR
CONTINUITY OF ANY FEEDERS OR BRANCH CIRCUITS
ORIGINATING OUTSIDE THE DEMOLITION AREA THAT SERVES ANY
ELECTRICAL EQUIPMENT OR DEVICES TO REMAIN AFTER
DEMOLITION. MODIFY OR REPLACE AS REQUIRED.
E FURNISH AND INSTALL CONDUIT AND/OR
COMMUNICATIONS/DATA WIRING AS NECESSARY FOR
CONTINUITY OF ANY WIRING ORIGINATING OUTSIDE THE
DEMOLITION AREA THAT SERVES ANY COMMUNICATIONS/DATA
EQUIPMENT OR DEVICES TO REMAIN AFTER DEMOLITION.
MODIFY OR REPLACE AS REQUIRED.
F DISCONNECT AND REMOVE LIGHT SWITCHES IN DEMOLITION
AREAS AS NECESSARY TO ACCOMMODATE NEW DOOR
CONFIGURATIONS.
G DISCONNECT AND REMOVE ANY EXISTING ELECTRICAL DEVICES
AND BACK BOXES AS NECESSARY WHERE NEW WALL
CONSTRUCTION WILL INTERSECT AN EXISTING WALL. FURNISH
AND INSTALL CONDUIT AND WIRE AS REQUIRED FOR
CONTINUITY OF CIRCUIT(S).
H FURNISH AND INSTALL BLANK COVER PLATES OVER ALL EXISTING
UNUSED OPENINGS.
KEYNOTES
1 DEMOLISH LIGHT FIXTURES, SWITCHES AND ASSOCIATED
UNUSED BRANCH CIRCUITRY, FIELD VERIFY QUANTITIES AND
REQUIREMENTS.
2 DEMOLISH RECEPTACLES AND ELECTRICAL DEVICES, UNLESS
NOTED OTHERWISE, AND ASSOCIATED UNUSED BRANCH
CIRCUITRY, FIELD VERIFY QUANTITIES AND REQUIREMENTS.
DTS
DTS
R L
DTS
DTS
RL4 RL4
DTS
DTS
R L
R L
R L
R L
R L
R L
R L
R L
R L
R L
R L
DTS
R L
R L
OS
OS
R L
R L
DTS
RL4
R L
R L
R L
R L
R L
R L
R L
D T
S
RL4
RL4
RL4
OS
R L
R L
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS OS OS OS
OS
OS
OS
OS
OS
OS
OS
OS
RL4
OS
OS
OS
OS
R L
R L
R L
R L
R L
R L
R L
R L
R L
R L
R L
R L
R L
R L
R L
R L
R
L
R L
R L
OS
DTS
R L
DTS
PROCEDURE 3
D129
PATIENT TOILET
D130
TOILET
D163
CORRIDOR
D134
CLEAN SUPPLY
D160 PASSAGE
C1-21
EXAM/ CONSULT
D128
EXAM/ CONSULT.
D126
PATIENT TOILET
D131
CORRIDOR
D122
PROCEDURE 2
D112
PATIENT TOILET
D113
PATIENT TOILET
D110
EXAM/ CONSULT.
D116
EXAM/ CONSULT.
D114
PROCEDURE 1
D109
EXAM/ CONSULT.
D104
CORRIDOR
D135A
INTAKE 1
D102INTAKE 2
D103
TEAM 1 WORK
ROOM
D148
HEIGHT &
WEIGHT
D105 PRIVATE VIRTUAL
D147
EXAM/ CONSULT.
D106
EXAM/ CONSULT.
D107
EXAM/ CONSULT.
D115
EXAM/ CONSULT.
D119
MED ROOM
D121
EXAM/ CONSULT.
D123
EXAM/ CONSULT.
D125
SOILED UTILITY
D127
OVERFLOW
STAFF WORK
ROOM
D159
TOILET
D158
PROCEDURE 6
D156
EXAM/ CONSULT.
D154
EXAM/ CONSULT.
D152
HOUSEKEEPING
D157
CORRIDOR
D136
EXAM/ CONSULT.
D155
EXAM/ CONSULT.
D153
MED ROOM
D151
EXAM/ CONSULT.
D149
EXAM/ CONSULT.
D145
EXAM/ CONSULT.
D143
EXAM/ CONSULT.
D141
EXAM/ CONSULT.
D144
EXAM/ CONSULT.
D142
EXAM/ CONSULT.
D140
EXAM/ CONSULT.
D138
HEIGHT &
WEIGHT
D137
EXAM/ CONSULT.
D139
CORRIDOR
D134
PATIENT TOILET
D146
CORRIDOR
D134
CORRIDOR
D135
CORRIDOR
D135
CORRIDOR
D136
TEAM 2 WORK
ROOM
D150
EXAM/ CONSULT.
D117
ELEC
D100A
PATIENT TOILET
D108PT
D111A
CORRIDOR
D134
BREAKROOM/
LOUNGE
D132
BREAKROOM/
LOUNGE
D132
TEAM 2 WORK
ROOM
D150
TELEHEALTH
D111D
STAFF UROLOGY
WORK ROOM
D111B
WAITING AREA
D100
E101B
E101CE101C
E101A
E101BE101B
E101B
E101CE101C
E101A
E101BE101B
B R A D E N
S .
C O X
6201070323
NO.
ENGINEER
S T
A
T E
O F M I C
H I
G A
N
R E
E N
I G
N
E L
ANOISSEFORP
D
E S
N E
C I
L
AREA - A
AREA - B
AREA - C
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
DWG. ___ OF 145
7GAE PROJECT NO.: 219123
Sprinkler:
600 E. Michigan Avenue, Suite B
Kalamazoo, MI 49007
P: 269.927.0144 www.7GenAE.com
2850 Eisenhower Ave, Suite 310
Alexandria, VA 22314
P: 202.617.8485 www.alliance.us.com
100% BID DOCUMENTS APRIL 6, 2023
FIRST FLOOR LIGHTING PLAN UPGRADE PRIMARY CARE
ANN ARBOR VAMC
506-20-103
1E
PROJECT DIRECTOR
APRIL 6, 2023 BC RM
100% BID
DOCUMENTS
E101
FULLY SPRINKLERED
NORTH
SCALE: 1/8" = 1'-0"
FIRST FLOOR LIGHTING PLAN
GENERAL LIGHTING NOTES
A ALL RECESSED LIGHTING FIXTURES IN LAY-IN CEILINGS SHALL BE
INSTALLED WITH 6' LONG (MAXIMUM) FLEXIBLE METAL CONDUIT.
B ALL MOUNTING HEIGHTS FOR LIGHTING FIXTURES ARE TO THE
BOTTOM OF THE FIXTURES UNLESS INDICATED OTHERWISE.
C REFER TO THE LIGHT FIXTURE SCHEDULE AND SEE ARCHITECTURAL
ELEVATIONS FOR MOUNTING HEIGHTS OF LIGHTING FIXTURES.
D REFER TO SECTION 26 0519 FOR MINIMUM CONDUCTOR SIZE
ADJUSTMENTS FOR VOLTAGE DROP.
F WIRE COUNTS FOR CIRCUIT CONDUCTORS ARE NOT SHOWN.
PROVIDE PROPER NUMBER OF CONDUCTORS TO ACHIEVE
CIRCUIT AND SWITCHING CONNECTIONS SHOWN.
J CIRCUIT WIRING IS NOT SHOWN EXCEPT FOR SWITCHING INTENT
OF FIXTURES AND CONTROL OF DEVICES.
K PROVIDE PROPER NUMBER OF CONDUCTORS TO ACHIEVE
CIRCUITING AND SWITCHING SHOWN.
M NIGHT LIGHT (FIXTURES WITH “NL” NOTED ADJACENT) AND
EMERGENCY ILLUMINATION UNITS SHALL BE CONNECTED TO THE
LOCAL NORMAL LIGHTING CIRCUIT AHEAD OF ANY LOCAL
SWITCHING, REFER TO N.E.C. SECTION 700-12(e) FOR
INFORMATION.
N RE-USE EXISTING LIGHTING HOME RUN CIRCUITRY FROM THE
DEMOLISHED FIXTURES. THE CIRCUIT NUMBER SHOWN IS AN
ATTEMPT TO DETERMINE EXISTING CIRCUIT. FIELD VERIFY THE
NEAREST LIGHTING CIRCUIT NUMBER, LOCATION, AVAILABLE
AMPACITY AND CONNECTION LOCATIONS. EXTEND THE
CIRCUITRY AS REQUIRED.
R L
R L
R L
R L
R L
R L
R L
R L
R L
R L
D T
S
RL4
RL4
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
RL4
OS
R L
R L
R L
R L
R L
R L
R L
R L
R L
OS
DTS
EXAM/ CONSULT.
D114
PROCEDURE 1
D109
EXAM/ CONSULT.
D104
CORRIDOR
D135A
INTAKE 1
D102
INTAKE 2
D103
TEAM 1 WORK
ROOM
D148
HEIGHT &
WEIGHT
D105
PRIVATE VIRTUAL
D147
EXAM/ CONSULT.
D106
EXAM/ CONSULT.
D107
EXAM/ CONSULT.
D143
EXAM/ CONSULT.
D141
EXAM/ CONSULT.
D144
EXAM/ CONSULT.
D142
EXAM/ CONSULT.
D140
EXAM/ CONSULT.
D138
HEIGHT &
WEIGHT
D137
EXAM/ CONSULT.
D139
L1-03
CL1-11
LS1-07
CR1-23
R1-22
CR244
CR244
CR222
CR244
CR222
CR244
CR244
CR244
CR244E
CR244E
CR244E
CR244E
CR223E
CR244E
CR244E
CR244CR223
CR223E
CR223
CR223CR223ECR223
CR222E
CR222
CR244E
CR244E
CR244E
CR244E
CR244E
CR244E
CR244E
CR244E
CR244E
CR244E
CR244E
CR244E
CR244E
CR244E
CORRIDOR
D135 CORRIDOR
D136
TEAM 2 WORK
ROOM
D150
CR244E
CR244E
CR244E
CR244E
360 180
L1-01- 22
CR223 CR223
CR223ECR223E
CR223CR223
CR223ECR223E
CR223CR223
CR222CR223E
CR223
CR223E
CR223
CR223E
CR223 CR223
CR223E CR223E
CR223 CR223
CR223E CR223E
CR223 CR223
EXC1
EXC1
EXC1
EXC1
ELEC
D100A
UW3
EXC1
C42
CR223
CR244E
CR244E
CR222
CR222
CR222 CR222E
CR222 CR222
PATIENT TOILET
D108
PT
D111A
STAFF UROLOGY
WORK ROOM
D111B
INTAKE 1
D102
WAITING AREA
D100
DTS
DTS
DTS
D
TS
CR223 CR223
CR223 CR223E CR223
CR223 CR223
CR223 CR223E CR223
LS1-07- 13
L1-01- 22
L1-01- 22
MX448
MX428
MX448
MX448
MX428
MX448E
MX448
MX428
MX448
MX448
MX428
MX448E
MX448
MX448
MX428
MX448
MX448
MX448
MX428
MX448E
MX448
MX448
MX428
MX448
MX448
MX448
MX428
MX448E
MX448
MX428
MX448
MX448
MX448
MX428
MX448E
MX448
MX448
CL1-09- 9
LS1-07- 14
LS1-07- 14
LS1-07- 14
L1-01- 13
LS1-07- 14
LS1-07- 14
LS1-07- 14
LS1-07- 14
LS1-07- 14
LS1-07- 14
LS1-07- 14
LS1-07- 14
LS1-07- 14
L1-01- 22
EXC1
CR222E
MX448
MX448
MX448
MX448
MX448MX448
MX448
MX448
MX448
MX448
CR223
CR223
MX428
L1-04- 144
D
66 77 7
B R A D E N
S .
C O X
6201070323
NO.
ENGINEER
S T
A
T E
O F M I C
H I
G A
N
R E
E N
I G
N
E L
ANOISSEFORP
D
E S
N E
C I
L
AREA - A
AREA - B
AREA - C
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
DWG. ___ OF 145
7GAE PROJECT NO.: 219123
Sprinkler:
600 E. Michigan Avenue, Suite B
Kalamazoo, MI 49007
P: 269.927.0144 www.7GenAE.com
2850 Eisenhower Ave, Suite 310
Alexandria, VA 22314
P: 202.617.8485 www.alliance.us.com
100% BID DOCUMENTS APRIL 6, 2023
ENLARGED LIGHTING PLAN -
AREA A
UPGRADE PRIMARY CARE
ANN ARBOR VAMC
506-20-103
1E
PROJECT DIRECTOR
APRIL 6, 2023 BC RM
100% BID
DOCUMENTS
E101A
FULLY SPRINKLERED
NORTH
SCALE: 1/4" = 1'-0"
ENLARGED LIGHTING PLAN - AREA A
KEYNOTES
1 UNSWITCHED EGRESS LIGHTING CIRCUITED TO THE PANEL AND
CIRCUIT SHOWN, FIELD VERIFY CIRCUIT AND PANEL AMPACITY
AVAILABILITY.
2 HOMERUN CIRCUITRY CONNECTED TO THE EXISTING
HOMERUN CIRCUITRY FROM THE DEMOLISHED LIGHT FIXTURES,
FIELD VERIFY THE ROUTE, CONNECTION REQUIREMENTS,
CIRCUIT NUMBER AND AVAILABLE PANEL AMPACITY.
3 PROVIDE TEMPORARY LIGHTING IN THE CORRIDOR DURING
CONSTRUCTION USING DEMOLISHED LIGHT FIXTURES AS
REQUIRED, FIELD VERIFY THE REQUIREMENTS.
4 HOMERUN CIRCUITRY ROUTED THROUGH THE EXISTING
BUILDING MANAGEMENT SYSTEM FOR CONTROL OF THE LIGHT
FIXTURES, FIELD VERIFY THE ROUTE AND CONNECTION
REQUIREMENTS.
5 EMERGENCY LIGHTING CIRCUITED TO THE PANEL AND CIRCUIT
SHOWN, FIELD VERIFY CIRCUIT AND PANEL AMPACITY
AVAILABILITY.
6 EXISTING LIGHT FIXTURE SHALL REMAIN.
7 NEW LOCATION FOR THE RELOCATED LIGHT FIXTURE, EXTEND
THE EXISTING CIRCUITRY TO THE NEW LOCATON SHOWN, FIELD
VERIFY THE REQUIREMENTS.
R L
DTS
DTS
R L
R L
R L
R L
R L
R L
R L
R L
DTS
R L
R L
OS
R L
DTS
RL4
R L
R L
R L
R L
R L
R L
R L
R L
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
R L
R L
R L
R L
R L
R L
R L
R L
R L
R L
R
L
R L
R L
OS
DTS
R L
PROCEDURE 3
D129
PATIENT TOILET
D130
EXAM/ CONSULT
D128
EXAM/ CONSULT.
D126
PATIENT TOILET
D131
CORRIDOR
D122
PROCEDURE 2
D112
PATIENT TOILET
D113
PATIENT TOILET
D110
EXAM/ CONSULT.
D116
EXAM/ CONSULT.
D114
PROCEDURE 1
D109
TEAM 1 WORK
ROOM
D148
EXAM/ CONSULT.
D107
EXAM/ CONSULT.
D115
EXAM/ CONSULT.
D117
EXAM/ CONSULT.
D119
MED ROOM
D121
EXAM/ CONSULT.
D123
EXAM/ CONSULT.
D125
SOILED UTILITY
D127
PROCEDURE 6
D156
EXAM/ CONSULT.
D154
EXAM/ CONSULT.
D152
HOUSEKEEPING
D157
CORRIDOR
D136
EXAM/ CONSULT.
D155
EXAM/ CONSULT.
D153
MED ROOM
D151
EXAM/ CONSULT.
D149
EXAM/ CONSULT.
D145
EXAM/ CONSULT.
D143
EXAM/ CONSULT.
D144
CR244E
CR244E
CR244E
CR244E
CR244E
CR244E
CR223E
CR223
CR223E
CR244
UW3
CR244
UW3
CR244
CR222E
CR222
CR222 CR222E CR222
CR223
CR222
CR222E
CR244E CR244E
CR244E CR244E
CR244E
CR244E
CR244
CR222E
UW3
CR244
CR244E
UW3
CR244E
CR244E
CR223E
CR223
CR244E
CR244E
CR244E
CR244E
CR223E
CR245 CR245
CR222
CR244E
CR222
CR244E CR244E
CR244E CR244E
CR244E
CR244E
CR244E
CR244E
CR244E
CR244E
CR244CR244
CR244 CR244
CR244CR244
CR244E
CR244E
CR244E
CR244E
UW3
CR244
CR244E
CR244E
CR244E
CR244E
CR244E
CR244E
CR244E
CR244E
CR244E
CR244E
CR244 CR244
CR244E
CR244E
CR244E
CR244E
CR244E CR244E
CR244ECR244E
CR244E CR223E
CR244CR244
CORRIDOR
D134
PATIENT TOILET
D146 EXAM/ CONSULT.
D145
CORRIDOR
D134
CORRIDOR
D135
EXAM/ CONSULT.
D117
CR244E
CR223E CR223 CR223E CR223 CR223E CR223 CR223E CR223 CR223E CR223
CR223E CR223E
CR223CR223
CR223ECR223E
CR223CR223
CR223E CR223E
CR223 CR223
CR223
CR223E CR223E
C41
C41
CR223 CR223
CR223ECR223E
CR223
CR223E
CR223
CR223E
CR244
CR223
CR223E
CR223
CR223E
CR223
CR223 CR223
CR223 CR223
CR223E CR223E
CR223 CR223
CR223E CR223E
CR222
CR223 CR223
CR223E CR223E
EXC1
EXC2
EXC1
EXC1
EXC1
CR223E CR223E
CR223E CR223E
EXC2
CR244E
CR244E
CR244E
CR244E
CR222
CR222
CR222E
CR222
CR222
CR222
CR222
CR222 CR222E
CR222 CR222
C25
C25C25
CORRIDOR
D134
TEAM 2 WORK
ROOM
D150
TELEHEALTH
D111D
STAFF UROLOGY
WORK ROOM
D111B
DTS
DTS
DTS
DTS
DTS
DTS
DTS
CR223 CR223E CR223
CR223 CR223
CR223 CR223E CR223
CR223 CR223
CR223 CR223E CR223
CR223 CR223
CR223 CR223E CR223
CR223 CR223
CR223 CR223E CR223
LS1-05- 9
LS1-05- 9
L1-01- 22
L1-01- 22
L1-01- 22
L1-01- 1
L1-01- 13
L1-01- 5
L1-01- 5
L1-01- 7
L1-01- 13
CL1-09- 9
CL1-09- 9
CL1-09- 9
L1-01- 1
CL1-09- 9
LS1-07- 14
LS1-07- 14
LS1-07- 14
LS1-07- 14
LS1-07- 14
LS1-07- 14
LS1-07- 14
LS1-07- 14
CL1-09- 9
LS1-07- 14
LS1-07- 14
LS1-07- 14
LS1-07- 14
LS1-07- 14
LS1-07- 14
LS1-07- 14
LS1-07- 14
LS1-07- 16
LS1-07- 16
L1-01- 12
TEMPORARY
WAITING ROOM
D164
MX448
MX448
MX448
MX448
MX448
MX448
MX448MX448
MX448
MX448
MX448
MX448
MX448
MX448
EXC1
EXC1
CR223
CR223
CR223
CR223
4L1-01- 13
L1-01- 223
LS1-07- 16
LS1-05- 9
L1-01- 12
LS1-05- 11
D
D
D
CR244E
CR244E
CR244E
CL1-09- 9
IUL
IUL
CL1-09- 9
B R A D E N
S .
C O X
6201070323
NO.
ENGINEER
S T
A
T E
O F M I C
H I
G A
N
R E
E N
I G
N
E L
ANOISSEFORP
D
E S
N E
C I
L
AREA - A
AREA - B
AREA - C
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
DWG. ___ OF 145
7GAE PROJECT NO.: 219123
Sprinkler:
600 E. Michigan Avenue, Suite B
Kalamazoo, MI 49007
P: 269.927.0144 www.7GenAE.com
2850 Eisenhower Ave, Suite 310
Alexandria, VA 22314
P: 202.617.8485 www.alliance.us.com
100% BID DOCUMENTS APRIL 6, 2023
ENLARGED LIGHTING PLAN -
AREA B
UPGRADE PRIMARY CARE
ANN ARBOR VAMC
506-20-103
1E
PROJECT DIRECTOR
APRIL 6, 2023 BC RM
100% BID
DOCUMENTS
E101B
FULLY SPRINKLERED
NORTH
SCALE: 1/4" = 1'-0"
ENLARGED LIGHTING PLAN - AREA B
KEYNOTES
1 HOMERUN CIRCUITRY CONNECTED TO THE EXISTING
HOMERUN CIRCUITRY FROM THE DEMOLISHED LIGHT FIXTURES,
FIELD VERIFY THE ROUTE, CONNECTION REQUIREMENTS,
CIRCUIT NUMBER AND AVAILABLE PANEL AMPACITY.
2 UNSWITCHED EGRESS LIGHTING CIRCUITED TO THE PANEL AND
CIRCUIT SHOWN, FIELD VERIFY CIRCUIT AND PANEL AMPACITY
AVAILABILITY.
3 HOMERUN CIRCUITRY ROUTED THROUGH THE EXISTING
BUILDING MANAGEMENT SYSTEM FOR CONTROL OF THE LIGHT
FIXTURES, FIELD VERIFY THE ROUTE AND CONNECTION
REQUIREMENTS.
4 PROVIDE TEMPORARY LIGHTING IN THE CORRIDOR DURING
CONSTRUCTION USING DEMOLISHED LIGHT FIXTURES AS
REQUIRED, FIELD VERIFY THE REQUIREMENTS.
5 EMERGENCY LIGHTING CIRCUITED TO THE PANEL AND CIRCUIT
SHOWN, FIELD VERIFY CIRCUIT AND PANEL AMPACITY
AVAILABILITY.
6 IN-USE LIGHT FIXTURE MOUNTED WITH THE CENTER AT 8'-0"
ABOVE THE FINISH FLOOR.
7 SWITCH WITH AN ENGRAVED FACEPLATE "CORRIDOR IN-USE
LIGHT".
R L
DTS
DTS
RL4 RL4
DTS
DTS
OS
OS
RL4
RL4
OS OS OS OS
OS
R L
PATIENT TOILET
D130
TOILET
D163
CORRIDOR
D134
CLEAN SUPPLY
D160
PASSAGE
C1-21
EXAM/ CONSULT
D128
SOILED UTILITY
D127
OVERFLOW
STAFF WORK
ROOM
D159
TOILET
D158
HOUSEKEEPING
D157
LS1-05
L1-01
CL1-09
R1-13
R1-14
CR1-15
CR244E
CR244E
CR223E
CR244
UW3
CR244CR244
CR244
UW3
CR244 CR244
CR244 CR244
CR244CR244
CR244 CR244
UW3
CR244
CR244
CR244
CR244
CR244CR244
CR244
CR244
CR223E
CR244CR244
CR244
CR244
CR244CR244
CR244
CR223E
CR223
CR244E CR244E
CR244ECR244E
CR244CR244
CORRIDOR
D134
CORRIDOR
D134
CR223
CR223E CR223 CR223E CR223 CR223E CR223 CR223E CR223 CR223E CR223
CR223E CR223E
CR223
EXC1
360360360360
EXC2
EXC1
EXC1
EXC1 CR223E CR223E
EXC2
C25
C25C25
CORRIDOR
D134
BREAKROOM/
LOUNGE
D132
DTS
DTS
DTS
DTS
CR223 CR223E CR223
LS1-05- 9
LS1-05- 9
LS1-05- 9
L1-01- 1
L1-01- 3
L1-01- 3
L1-01- 3 L1-01- 3
L1-01- 3
L1-01- 12
L1-01- 13
L1-01- 5
L1-01- 5
L1-01- 7
L1-01- 1
CL1-09- 9
LS1-07- 16
LS1-07- 16
L1-01- 12
MX448MX448
EXC1
4L1-01- 13
LS1-07- 16
EXC1
PRIVATE WORK
ROOM
D162
B R A D E N
S .
C O X
6201070323
NO.
ENGINEER
S T
A
T E
O F M I C
H I
G A
N
R E
E N
I G
N
E L
ANOISSEFORP
D
E S
N E
C I
L
AREA - A
AREA - B
AREA - C
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
DWG. ___ OF 145
7GAE PROJECT NO.: 219123
Sprinkler:
600 E. Michigan Avenue, Suite B
Kalamazoo, MI 49007
P: 269.927.0144 www.7GenAE.com
2850 Eisenhower Ave, Suite 310
Alexandria, VA 22314
P: 202.617.8485 www.alliance.us.com
100% BID DOCUMENTS APRIL 6, 2023
ENLARGED LIGHTING PLAN -
AREA C
UPGRADE PRIMARY CARE
ANN ARBOR VAMC
506-20-103
1E
PROJECT DIRECTOR
APRIL 6, 2023 BC RM
100% BID
DOCUMENTS
E101C
FULLY SPRINKLERED
NORTH
SCALE: 1/4" = 1'-0"
ENLARGED LIGHTING PLAN - AREA C
KEYNOTES
1 UNSWITCHED EGRESS LIGHTING CIRCUITED TO THE PANEL AND
CIRCUIT SHOWN, FIELD VERIFY CIRCUIT AND PANEL AMPACITY
AVAILABILITY.
2 HOMERUN CIRCUITRY ROUTED THROUGH THE EXISTING
BUILDING MANAGEMENT SYSTEM FOR CONTROL OF THE LIGHT
FIXTURES, FIELD VERIFY THE ROUTE AND CONNECTION
REQUIREMENTS.
3 HOMERUN CIRCUITRY CONNECTED TO THE EXISTING
HOMERUN CIRCUITRY FROM THE DEMOLISHED LIGHT FIXTURES,
FIELD VERIFY THE ROUTE, CONNECTION REQUIREMENTS,
CIRCUIT NUMBER AND AVAILABLE PANEL AMPACITY.
4 PROVIDE TEMPORARY LIGHTING IN THE CORRIDOR DURING
CONSTRUCTION USING DEMOLISHED LIGHT FIXTURES AS
REQUIRED, FIELD VERIFY THE REQUIREMENTS.
5 EMERGENCY LIGHTING CIRCUITED TO THE PANEL AND CIRCUIT
SHOWN, FIELD VERIFY CIRCUIT AND PANEL AMPACITY
AVAILABILITY.
42"
EM
42"
EM
60"
60" 60"
60"
EM
EM
42"
EM
TP TP
TP
TP
42"
EM
GFI
TP
TP
GFI
TP
TP
42"
EM
42"
EM
42"
TP
TP
42"
EM
TP
TP
TP
TP
TP TP
TP
TP
TP
TP
GFI
34"
TP
GFI
34"
TP
TP
GFI
TP
GFI
TP
GFI
TP
GFI
TP
GFI
TP
GFI
TP
GFI
EM
TP
GFI
34"
TP
GFI
34"
TP
GFI
34"
TP
GFI
34"
TP
GFI
34"
TP
GFI
TP
GFI
TP
GFI
TP
GFI
TP
GFI
TP
TP
42"
TP
EM
EM
TP
TP
TPG
FI
TPTP
TP
TP
60"
TP
TP
GFI
42"
EM
TP
GFI
34"
TP
TP
TP
TP
TP
TP
TP
GFI
34"
TP
TP
GFI
TP
GFI
TP
GFI
TP
GFI
TP
GFI
TP
TP
TP
GFI
42"
TP
TP
TP
GFI
TP
TP
GFI
42"
TP
GFI
34"
TP
GFI
TP
GFI
34"
TP
TP
GFI
42"
TP
TP
TP
TP
TP
TP
TPG
FI
TP
TPG
FI
TP G
FI
TP G
FI
42"
EM
42"
EM
EM
EM
J J
TP
J
60"
60"
60"
J J J J
J
48"
J
J4 "J 4
TP
CLNG
J
CLNG
J
C L N
G
J
CLNG
J
C L N
G
J
J
J
48"
J
48"
J
48"
JJ J
J
J
48"
J4
J
J4
J
J
48"
J
J 4
J
J
J
48"
CLNG
J
J
CLNG
J
J
CLNG
J
J
CLNG
J
CLNG
J
CLNG
J
CLNG
J
CLNG
J
CLNG
J
CLNG
J
CLNG
J
J J
J
J
J
J
J
J
J
J
J
J
48"
GFI
TP
TPG
FI
"TP G
FI
TP
GFI
42"
J J
48"
J
48"
JJ
48"
J
48"
J
48"
J
48"
J
J
J
J
J
J
J
48"
J
J
48"
60"
TP
GFI
34"
TP
GFI
34"
TP
GFI
34"
TP
GFI
34"
TP
GFI
34"
TP
GFI
34"
TP
GFI
34"
TP
GFI
34"
TP
GFI
34"
J
J
48"
A
C
A C
A
C
A C
J
J
48"
J 4
J 4
J
J
J
J
CLNG
J
CLNG
J
CLNG
J
CLNG
J
CLNG
J
CLNG
J
CLNG
J
CLNG
J
CLNG
J
J
J
PROCEDURE 3
D129
PATIENT TOILET
D130
TOILET
D163
CORRIDOR
D134
CLEAN SUPPLY
D160 PASSAGE
C1-21
EXAM/ CONSULT
D128
EXAM/ CONSULT.
D126
PATIENT TOILET
D131
CORRIDOR
D122
PATIENT TOILET
D113
PATIENT TOILET
D110
EXAM/ CONSULT.
D114
PROCEDURE 1
D109
EXAM/ CONSULT.
D104
CORRIDOR
D135A
INTAKE 1
D102
INTAKE 2
D103
TEAM 1 WORK
ROOM
D148
HEIGHT &
WEIGHT
D105
PRIVATE VIRTUAL
D147
EXAM/ CONSULT.
D106
EXAM/ CONSULT.
D107
EXAM/ CONSULT.
D115
EXAM/ CONSULT.
D117
EXAM/ CONSULT.
D119
MED ROOM
D121
EXAM/ CONSULT.
D123
EXAM/ CONSULT.
D125
SOILED UTILITY
D127
PROCEDURE 6
D156
EXAM/ CONSULT.
D154
EXAM/ CONSULT.
D152
OVERFLOW
STAFF WORK
ROOM
D159
TOILET
D158
HOUSEKEEPING
D157
CORRIDOR
D136
EXAM/ CONSULT.
D155
EXAM/ CONSULT.
D153
MED ROOM
D151
EXAM/ CONSULT.
D149
EXAM/ CONSULT.
D143
EXAM/ CONSULT.
D141
EXAM/ CONSULT.
D144
EXAM/ CONSULT.
D142
EXAM/ CONSULT.
D140
EXAM/ CONSULT.
D138
HEIGHT &
WEIGHT
D137
EXAM/ CONSULT.
D139
TEAM 2 WORK
ROOM
D150
PROCEDURE 2
D112
EXAM/ CONSULT.
D116
PATIENT TOILET
D146
ELEC
D100A
CORRIDOR
D135
TEAM 2 WORK
ROOM
D150
CORRIDOR
D135
TEAM 1 WORK
ROOM
D148 EXAM/ CONSULT.
D145
CORRIDOR
D134
CORRIDOR
D134 E201B
E201CE201C
E201A
E201BE201B
E201B
E201CE201C
E201A
E201BE201B
STAFF UROLOGY
WORK ROOM
D111B
BREAKROOM/
LOUNGE
D132
TELEHEALTH
D111D
PATIENT TOILET
D108
WAITING AREA
D100
PT
D111A
B R A D E N
S .
C O X
6201070323
NO.
ENGINEER
S T
A
T E
O F M I C
H I
G A
N
R E
E N
I G
N
E L
ANOISSEFORP
D
E S
N E
C I
L
AREA - A
AREA - B
AREA - C
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
DWG. ___ OF 145
7GAE PROJECT NO.: 219123
Sprinkler:
600 E. Michigan Avenue, Suite B
Kalamazoo, MI 49007
P: 269.927.0144 www.7GenAE.com
2850 Eisenhower Ave, Suite 310
Alexandria, VA 22314
P: 202.617.8485 www.alliance.us.com
100% BID DOCUMENTS APRIL 6, 2023
FIRST FLOOR POWER PLAN UPGRADE PRIMARY CARE
ANN ARBOR VAMC
506-20-103
1E
PROJECT DIRECTOR
APRIL 6, 2023 BC RM
100% BID
DOCUMENTS
E201
FULLY SPRINKLERED
GENERAL POWER NOTES
A WHERE CONNECTED TO A 20A. BRANCH CIRCUIT SUPPLYING AN
INDIVIDUAL RECEPTACLE (SIMPLEX OR DUPLEX), THE
RECEPTACLE SHALL BE RATED AT 20A.
B REFER TO SECTION 26 0519 FOR MINIMUM CONDUCTOR SIZE
ADJUSTMENTS FOR VOLTAGE DROP.
C CIRCUIT WIRING IS NOT SHOWN EXCEPT FOR SWITCHING INTENT
OF FIXTURES AND CONTROL OF DEVICES.
D PROVIDE PROPER NUMBER OF CONDUCTORS TO ACHIEVE
CIRCUITING AND SWITCHING SHOWN.
E CIRCUIT NUMBERS AT DEVICES CORRESPOND TO PANELBOARD
BREAKERS (SEE PANELBOARD SCHEDULE). BRANCH CIRCUITS
SHALL BE SIZED ACCORDING TO THE CIRCUIT BREAKER RATING,
UNLESS INDICATED OTHERWISE ON THE ELECTRICAL EQUIPMENT
SCHEDULE.
F SINGLE PHASE BRANCH CIRCUITS SHALL NOT SHARE NEUTRALS.
G THE CONTRACTOR SHALL PROVIDE THE FIRE ALARM SYSTEM AND
NURSE CALL SYSTEM'S DEVICES AND DATA CONNECTION
CONDUITS AND BOXES, PER THE "INFORMATION BOX DETAIL".
REFER TO THE SPECIAL SYSTEMS PLANS FOR BOX LOCATIONS.
FIELD VERIFY THE BOX LOCATIONS AND CONDUIT ROUTES.
H THE CONTRACTOR SHALL PROVIDE THE REQUIRED POWER FOR
ALL MECHANICAL OR PLUMBING EQUIPMENT SPECIFIED IN THE
CONTRACT DOCUMENTS, EVEN IF NOT SHOWN ON THE POWER
PLANS. FIELD VERIFY THE POWER REQUIREMENTS OF ALL
MECHANICAL AND PLUMBING EQUIPMENT, WITH THE
EQUIPMENT SUPPLIERS, PRIOR TO PREPARING SUBMITTALS OR
ORDERING ANY SWITCHGEAR OR EQUIPMENT. SUPPLIED
PLUMBING AND/OR MECHANICAL EQUIPMENT MAY VARY.
I THE CONTRACTOR SHALL FIELD VERIFY THE ROUGH-IN
DIMENSIONS OF ALL FLOOR BOXES, DATA OUTLETS, TV OUTLETS
AND TV RECEPTACLES PRIOR TO ANY INSTALLATION. ANY
CHANGE OF LOCATION OF A BOX THAT WAS NOT VERIFIED WITH
THE OWNER PRIOR TO INSTALLATION SHALL BE RELOCATED AT
THE CONTRACTOR'S EXPENSE TO THE SATISFACTION OF THE
OWNER.
J FOR EACH THERMOSTAT, TEMPERATURE SENSOR OR WALL
MOUNTED CONTROL DEVICE PROVIDE A JUNCTION BOX, WITH
A SINGLE GANG MUD RING, AT 48” ABOVE THE FINISH FLOOR
WITH A ¾” CONDUIT (WITH A PULL STRING) TO ABOVE THE
CEILING FOR THE MECHANICAL CONTROLS. REFER TO THE
MECHANICAL PLANS FOR INFORMATION.
K RE-USE EXISTING ELECTRICAL DEVICE HOME RUN CIRCUITRY
FROM THE DEMOLISHED DEVICES. THE CIRCUIT NUMBER SHOWN
IS AN ATTEMPT TO DETERMINE EXISTING CIRCUIT. FIELD VERIFY
THE NEAREST RECEPTACLE CIRCUIT NUMBER, LOCATION,
AVAILABLE AMPACITY AND CONNECTION LOCATIONS. EXTEND
THE CIRCUITRY AS REQUIRED.
L REFER TO THE INTERSTITIAL MECHANICAL PLANS FOR THE VAV
BOX LOCATIONS FOR POWER CONNECTIONS. VAV BOXES ARE
SHOWN ON THE FIRST FLOOR POWER PLAN FOR CLARITY ONLY.
M PROVIDE ALL POWER CONNECTIONS FOR THE PNUEMATIC TUBE
INFORMATION TRANSFER SYSTEM. PROVIDE ALL COMPONENTS
REQUIRED FOR A COMPLETE OPERATIONAL SYSTEM. REFER TO
THE MANUFACTURER'S INSTALLATION REQUIREMENTS.
NORTH
SCALE: 1/8" = 1'-0"
FIRST FLOOR POWER PLAN
42"
EM
60" 60"
42"
EM
TP TP
TP
GFI
TP
42"
EM
42"
TP
TP
TP
TP
TP
TPTP
TP
GFI
TP
GFI
TP
GFI
TP
GFI
34"
TP
GFI
34"
TP
GFI
EM
TP
TPG
FI
TPTP
TP
TP
60"
TP
TP
GFI
42"
EM
TP
GFI
34"
TP
TP
GFI
34"
TP
TP
GFI
TP
GFI
TP
TP
TP
GFI
42"
TP
GFI
TP
TP
GFI
42"
TP
GFI
34"
TP
GFI
TP
GFI
34"
TP
TP
TP
J
60"
60"
J J J J
J
48"
J
J4 "J
C L N
G
J
C L N
G
J
J
J
48"
J
CLNG
J
CLNG
J
J
J
J
48"
J
48"
J
J
J
J
48"
J
J
48"
TP
GFI
34"
J 4
J
J
J
J
J
CLNG
J
CLNG
J
CLNG
J
CLNG
J
PROCEDURE 1
D109
EXAM/ CONSULT.
D104
CORRIDOR
D135A
INTAKE 1
D102INTAKE 2
D103
TEAM 1 WORK
ROOM
D148
HEIGHT &
WEIGHT
D105
PRIVATE VIRTUAL
D147
EXAM/ CONSULT.
D106
EXAM/ CONSULT.
D107
EXAM/ CONSULT.
D115
CR1-23
R1-22
CL1-11
LS1-07
L1-03
A C
EM TP
A C
EM G
FI
A C
G
FI
A C
G
FI
A C
G
FI TP
AC
GFI
TP
AC
GFI
TP
G
FI
G
FI
EXAM/ CONSULT.
D143
EXAM/ CONSULT.
D141
EXAM/ CONSULT.
D142
EXAM/ CONSULT.
D140
EXAM/ CONSULT.
D138
HEIGHT &
WEIGHT
D137
EXAM/ CONSULT.
D139
TEAM 2 WORK
ROOM
D150
ELEC
D100A
C…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .