Drawings D1 - 506-20-103.pdf

PDF 11 MB Posted

Attached to
Z1DA--Upgrade Primary Care Building 1E, 506-20-103
Solicitation number
36C25023B0057
Issued by

About this file

This document is a pre-solicitation notice for an upcoming invitation for bid from the Department of Veterans Affairs for project 506-20-103 to upgrade a primary care building at the LTC Charles S. Kettles Veterans Administration Medical Center in Ann Arbor, Michigan. The project scope involves internal demolition of the existing primary care area and full reconstruction of a new primary care area. The solicitation is planned for release on May 27, 2023 and will have a bid due date specified therein. The procurement is set aside solely for verified Service-Disabled Veteran Owned Small Businesses and has an estimated value between $5-10 million. The contract type will be firm fixed price with an anticipated award date within 550 days of bid opening. Interested parties should monitor the Contract Opportunities website at www.sam.gov for solicitation details and amendments.

View the file

Other files

File Type Posted
Notice of Award Aug 22 - 506-20-103.pdf PDF
Wage Determination MI20230100 July 21 - 506-21-103.pdf PDF
36C25023B0057 0003.pdf PDF
34 AD121 FIRST FLOOR REFLECTED CEILING DEMOLITION PLAN - 506-20-103.pdf PDF
Project Manual Volume 1 Updated through Addendum No 1 - 506-20-103.pdf PDF
AE Addendum 01 Write Up - 506-20-103.pdf PDF
36C25023B0057 0002.pdf PDF
01 GI000 Cover Sheet - 506-20-103.pdf PDF
Pre-Bid Site Visit Agenda signed - 506-20-103.pdf PDF
36C25023B0057 0001.pdf PDF
Pre Bid Site Visit Attendance Log signed - 506-20-103.pdf PDF
Drawings A2 - 506-20-103.pdf PDF
Drawings C - 506-20-103.pdf PDF
Wage Determination MI20230100 Apr 7 - 506-20-103.pdf PDF
Sole Source Justification Simplex KO signed - 506-20-103.pdf PDF
RFI Form - 506-20-103.pdf PDF
Specifications Volume 2 - 506-20-103.pdf PDF
Sole Source Justification Swisslog KO signed - 506-20-103.pdf PDF
Sole Source Justification Rauland R5 KO signed - 506-20-103.pdf PDF
Drawings B - 506-20-103.pdf PDF
Drawings D2 - 506-20-103.pdf PDF
36C25023B0057_1 cleared - 506-20-103.pdf PDF
EMR Certification Form - 506-20-103.pdf PDF
Specifications Volume 1 - 506-20-103.pdf PDF
Drawings A1 - 506-20-103.pdf PDF
Sole Source Justification Siemens Desigo KO signed - 506-20-103.pdf PDF
36C25023B0057.docx DOCX document
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

J

XX-1

K

D T

S

T

TD

D

EM

P

P

J

R

TC

H

T

F

F

F

F

XX-1 XX-1 XX-1

XX-1

D

F

P

FR

CLNG

J

CLNG

48"

F S

D

V

M

ES

ML

DC

CL

CR

MD

E

B

S

P

N

TV

N

N

TP

1P 1 POLE (2P, 3P, 4P, ETC.)

A AMPERE

AC ABOVE COUNTER

ACLG ABOVE CEILING

ADO AUTOMATIC DOOR OPENER

AF AMP FRAME

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AFI ARC FAULT CIRCUIT

INTERRUPTER

AHU AIR HANDLING UNIT

AL ALUMINUM

ALT ALTERNATE

AMP AMPERE

AMPL AMPLIFIER

ANNUN ANNUNCIATOR

APPROX APPROXIMATELY

AQ-STAT AQUASTAT

ARCH ARCHITECT, ARCHITECTURAL

AS AMP SWITCH

AT AMP TRIP

ATS AUTOMATIC TRANSFER SWITCH

AUTO AUTOMATIC

AUX AUXILIARY

AV AUDIO VISUAL

AWG AMERICAN WIRE GAUGE

BATT BATTERY

BD BOARD

BLDG BUILDING

BMS BUILDING MANAGEMENT SYSTEM

C CONDUIT

CAB CABINET

CAT CATALOG

CATV CABLE TELEVISION

CB CIRCUIT BREAKER

CCTV CLOSED CIRCUIT TELEVISION

CKT CIRCUIT

CLG CEILING

COMB COMBINATION

CMPR COMPRESSOR

CONN CONNECTION

CONST CONSTRUCTION

CONT CONTINUATION OR

CONTINUOUS

CONTR CONTRACTOR

CONV CONVECTOR

CP CIRCULATING PUMP

CRT CATHODE-RAY TUBE

CT CURRENT TRANSFORMER

CTR CENTER

CU COPPER

DCP DOMESTIC WATER CIRCULATING

PUMP

DEPT DEPARTMENT

DET DETAIL

DIA DIAMETER

DISC DISCONNECT

DIST DISTRIBUTION

DN DOWN

DPR DAMPER

DS SAFETY DISCONNECT SWITCH

DT DOUBLE THROW

DWG DRAWING

EC ELECTRICAL CONTRACTOR

ELEC ELECTRIC, ELECTRICAL

ELEV ELEVATOR

ELU EMERGENCY LIGHTING UNIT

EM EMERGENCY

EMS ENERGY MANAGEMENT SYSTEM

EMT ELECTRICAL METALLIC TUBING

EP ELECTRIC PNEUMATIC

EQUIP EQUIPMENT

EWC ELECTRIC WATER COOLER

EXIST EXISTING

EXH EXHAUST

EXP EXPLOSION PROOF

FA FIRE ALARM

FABP FIRE ALARM BOOSTER POWER

SUPPLY PANEL

FACP FIRE ALARM CONTROL PANEL

FCU FAN COIL UNIT

FIXT FIXTURE

FLR FLOOR

FLUOR FLUORESCENT

FU FUSE

FUDS FUSED SAFETY DISCONNECT

SWITCH

GA GAUGE

GAL GALLON

GALV GALVANIZED

GC GENERAL CONTRACTOR

GEN GENERATOR

GFI GROUND FAULT CIRCUIT

INTERRUPTER

GFP GROUND FAULT PROTECTOR

GND GROUND

GRS GALVANIZED RIGID STEEL

(CONDUIT)

GYP BD GYPSUM BOARD

HOA HANDS-OFF-AUTOMATIC SWITCH

HORIZ HORIZONTAL

HP HORSEPOWER

HPF HIGH POWER FACTOR

HT HEIGHT

HTG HEATING

HTR HEATER

HV HIGH VOLTAGE

HVAC HEATING, VENTILATING AND AIR

CONDITIONING

IC INTERRUPTING CAPACITY

IG ISOLATED GROUND

IMC INTERMEDIATE METAL CONDUIT

INCAND INCANDESCENT

IR INFRARED

I/W INTERLOCK WITH

J-BOX JUNCTION BOX

KV KILOVOLT

KVA KILOVOLT-AMPERE

KVAR KILOVOLT-AMPERE REACTIVE

KW KILOWATT

KWH KILOWATT HOUR

LOC LOCATE OR LOCATION

LT LIGHT

LTG LIGHTING

LTNG LIGHTNING

LV LOW VOLTAGE

MAX MAXIMUM

MAG.S MAGNETIC STARTER

M/C MOMENTARY CONTACT

MC MECHANICAL CONTRACTOR

ELECTRICAL ABBREVIATIONS LIST ELECTRICAL SYMBOL NOTES

EXIT LIGHTS. STEM INDICATES WALL MOUNTING. NO STEM INDICATES

CEILING MOUNTING. SHADED AREA INDICATES ILLUMINATED FACE(S).

ARROW INDICATES DIRECTIONAL ARROW ON ILLUMINATED FACE(S).

THE CIRCUIT DESIGNATION IS INDICATED BY A NUMBER. EXAMPLE: THE

WALL MOUNTED EXIT LIGHT TYPE "E1" WITH SINGLE FACE AND

DIRECTIONAL ARROW IS CONNECTED TO CIRCUIT 1.

DEVICES. THE CIRCUIT DESIGNATION IS INDICATED BY A NUMBER.

THE SWITCH

DESIGNATION IS INDICATED BY A LOWER CASE LETTER. EXAMPLE:

SPLIT DUPLEX RECEPTACLE IS CONNECTED TO CIRCUIT 1 AND ONE

RECEPTACLE OUTLET IS CONTROLLED BY SWITCH "d".

THE CONTROL DEVICE DESIGNATION IS INDICATED BY A LOWER CASE

LETTER. EXAMPLE: SINGLE POLE SWITCH "d" TO CONTROL LIGHTING

FIXTURES INDICATED BY "d".

WALL BOX DIMMER WITH SIZE AS INDICATED AT DEVICE. EXAMPLE: 600

WATT WALL BOX DIMMER TO CONTROL LIGHTING FIXTURES INDICATED

BY "e". SEE SPECIFICATIONS FOR WATTAGE IF NOT INDICATED.

SPECIAL CONNECTIONS. THE EQUIPMENT IS INDICATED BY A NUMBER

IN A CIRCLE. SEE THE MOTOR AND EQUIPMENT SCHEDULE FOR THE

LOAD DESCRIPTION AND TYPE OF CONNECTION. THE CIRCUIT

DESIGNATION IS INDICATED BY NUMBER(S) ADJACENT TO THE SYMBOL.

EXAMPLE: EQUIPMENT NO. ELEC-1; 1 PHASE CONNECTION TO

CIRCUITS 2, 4.

MOTOR CONNECTIONS. THE MOTOR IS INDICATED BY A NUMBER

WITHIN OR CHARACTERS ADJACENT TO THE MOTOR SYMBOL. SEE

THE MOTOR AND EQUIPMENT SCHEDULE FOR THE MOTOR

DESCRIPTION AND ELECTRICAL REQUIREMENTS.

TRANSFORMERS. THE TRANSFORMER TYPE IS INDICATED BY A NUMBER

FOLLOWING THE UPPER CASE LETTER "T". SEE THE TRANSFORMER

SCHEDULE OR THE SINGLE LINE DIAGRAM FOR THE TRANSFORMER

DESCRIPTION AND REQUIREMENTS. EXAMPLE: TRANSFORMER TYPE "T1".

PANELBOARDS. PANELBOARD DOORS MAY BE SHOWN TO

INDICATE OPENING SIDE OF RECESSED PANELBOARDS. SEE

PANELBOARD IDENTIFICATION FOR DESIGNATION CODES.

CONDUIT SHOWN WITHOUT SLASH MARKS SHALL CONTAIN 1 # 12

CONDUCTOR PER PHASE, NEUTRAL, AND GROUND IN 1/2" CONDUIT

UNLESS SPECIFIC EQUIPMENT REQUIRES A DIFFERENT SIZE.

CONDUIT SHOWN SHALL CONTAIN 1 # 10 CONDUCTOR PER PHASE IN

ELECTRICAL CODE SIZED MINIMUM CONDUIT UNLESS A CONDUCTOR

AND CONDUIT SIZE IS SHOWN ADJACENT.

HOME RUN TO BRANCH CIRCUIT PANELBOARD. THE PANELBOARD

DESIGNATION IS SHOWN ADJACENT TO THE HOME RUN ARROW AS A

NUMERATOR AND THE CIRCUIT DESIGNATION IS SHOWN AS THE

DENOMINATOR. CIRCUIT BREAKER SIZES (AMPS/NUMBER OF POLES)

ARE SHOWN IN THE PANELBOARD SCHEDULE WITH THE

CORRESPONDING PANELBOARD AND CIRCUIT DESIGNATION.

EXAMPLE: HOME RUN TO PANELBOARD P4N-102; CIRCUITS 1, 3, 5.

SYMBOLSYMBOL SYMBOLDESCRIPTION DESCRIPTION DESCRIPTION

FIRE ALARM HORN W/STROBE

FIRE ALARM BELL

FIRE ALARM BELL W/STROBE

FIRE ALARM CHIME W/STROBE

THERMOSTAT

HUMIDISTAT

TIME CONTROL SWITCH

RELAY

CABLE TAP BOX

SAFETY DISC. SW. (FUSED)

SAFETY DISC. SW. (NON-FUSED)

COMB. MOTOR STARTER (FUSED)

MOTOR

TRANSFORMER

FLOOR JUNCTION BOX

JUNCTION BOX

UTILITY SERVICE POWER POLE

STATIC GROUND RECEPTACLE

SURGERY SERVICE COLUMN

POWER POLE (OPEN OFFICE STYLE)

MULTIOUTLET ASSEMBLY

RECEPTACLE ON CORD REEL

FLOOR DUPLEX RECEPTACLE

240V RECEPTACLE

FOURPLEX RECEPTACLE ON

EMERGENCY CIRCUIT

FOURPLEX RECEPTACLE

DUPLEX RECEPTACLE ON

EMERGENCY CIRCUIT

DUPLEX ISOLATED GROUND RECEPT.

SPLIT DUPLEX RECEPTACLE

DUPLEX RECEPTACLE

SINGLE RECEPTACLE

PUSH BUTTON

TIME DELAY SWITCH

TIMER SWITCH

OCCUPANCY SENSOR W/ MANUAL

SWITCH

DIMMER SWITCH

SWITCH W/PILOT

KEYED SWITCH

4-WAY SWITCH

3-WAY SWITCH

SINGLE POLE SWITCH

BUS DUCT W/ PLUG IN DISCONNECT

PS - D2

T1

PANELBOARD IDENTIFICATION

KEYED NOTE (SEE SCHEDULE)

NUMBER OF SHEET WHERE DETAIL APPEARS

NUMBER OF DETAIL ON SHEET

REVISION NUMBER - SHOWN ON PLANS

ROOM NAME AND NUMBER

DEMOLISHED

ITEM

AREA NOT IN

CONTRACT

XX-1 IDENTITY (SEE SCHEDULE)

XX-1

EXISTING TO REMAIN

XX-1

RELOCATED

XX-1

DEMOLISHED

1d d e

2,4

T1

FLOOR CLEARANCE AREA

CONDUIT IN CEILING, FLOOR OR WALL AS REQUIRED BY FIELD

CONDITIONS

CONDUIT IN FLOOR

P4N-102

1. EQUIPMENT DESIGNATION:

L = LIGHTING

P = POWER

D = DISTRIBUTION

S = SWITCHBOARD

M = MOTOR CONTROL CENTER

R = RELAY PANEL

2. VOLTAGE DESIGNATION:

1 = 120/240V - 1PH

2 = 240V - 3PH

3 = 208Y/120V - 3PH

4 = 480Y/277V - 3PH

5 = 120/208 - 1PH

6 = SPECIAL

3. SYSTEM DESIGNATION:

N = NORMAL

E = EMERGENCY

C = POWER CONDITIONED

U = UNINTERRUPTIBLE POWER SOURCE

4. FLOOR DESIGNATION:

B = BASEMENT

G = GROUND

1 = FIRST FLOOR

2 = SECOND FLOOR

ETC.

5. PANEL NO. DESIGNATION:

01 = PANELBOARD #1

02 = PANELBOARD #2

03 = PANELBOARD #3

ETC.

FIRE ALARM PULL STATION

FIRE ALARM DOOR HOLDER

FIRE ALARM DOOR CLOSER

FIRE ALARM SHUT DOWN RELAY

CEILING DATA OUTLET

FLOOR DATA OUTLET

# OF VOICE AND # OF DATA OUTLETS.

EXAMPLE 1V2D = 1 VOICE, 2 DATA

P4N-102

1, 3, 5

#10

#12

EXISTING TO REMAIN

EXISTING TO BE REMOVED

NEW

GRAPHICAL REPRESENTATION OF PHASING, TYPICAL FOR ALL

SYMBOLS

CEILING DUPLEX RECEPTACLE

CEILING JUNCTION BOX

FLOOR TELEPHONE OUTLET

GFI DUPLEX RECEPTACLE (FEED

THROUGH)

GFI WEATHERPROOF RECEPTACLE

DUPLEX RECEPTACLE

(DESIGNATES SPECIFIC MTG. HT.)

CLNG

ELEC-1

Room

FIRE ALARM SPEAKER W/STROBE

MCB MAIN CIRCUIT BREAKER

MCC MOTOR CONTROL CENTER

MDC MAIN DISTRIBUTION CENTER

MDP MAIN DISTRIBUTION PANEL

MFR MANUFACTURER

MFS MAIN FUSED DISCONNECT

SW

MH MANHOLE

MIC MICROPHONE

MIN MINIMUM

MISC MISCELLANEOUS

MLO MAIN LUGS ONLY

MMS MANUAL MOTOR STARTER

MOA MULTIOUTLET ASSEMBLY

MSP MOTOR STARTER

PANELBOARD

MSBD MAIN SWITCHBOARD

MT MOUNT

MT.C EMPTY CONDUIT

MTS MANUAL TRANSFER SWITCH

MTR MOTOR, MOTORIZED

N.C. NORMALLY CLOSED

NEC NATIONAL ELECTRICAL CODE

NEMA NATIONAL ELECTRICAL

MANUFACTURER'S

ASSOCIATION

NFDS NON-FUSED SAFETY

DISCONNECT SWITCH

NIC NOT IN CONTRACT

NL NIGHT LIGHT

N.O. NORMALLY OPEN

NPF NORMAL POWER FACTOR

NTS NOT TO SCALE

OH OVERHEAD

OL OVERLOADS

PA PUBLIC ADDRESS

PB PULL BOX OR PUSHBUTTON

PE PNEUMATIC ELECTRIC

PED PEDESTAL

PF POWER FACTOR

PH PHASE

PIV POST INDICATING VALVE

PNL PANEL

PP POWER POLE

PR PAIR

PRI PRIMARY

PROJ PROJECTION

PRV POWER ROOF VENTILATOR

PT POTENTIAL TRANSFORMER

PVC POLYVINYL CHLORIDE

(CONDUIT)

PWR POWER

QUAN QUANTITY

RCPT RECEPTACLE

REQD REQUIRED

RM ROOM

RSC RIGID STEEL CONDUIT

RTU ROOF TOP UNIT

SC SURFACE CONDUIT

SEC SECONDARY

SHT SHEET

SIM SIMILAR

S/N SOLID NEUTRAL

SPEC SPECIFICATION

SPKR SPEAKER

SP SPARE

SR SURFACE RACEWAY

SS STAINLESS STEEL

SSW SELECTOR SWITCH

S/S STOP/START PUSHBUTTONS

STA STATION

STD STANDARD

SURF SURFACE MOUNTED

SW SWITCH

SWBD SWITCHBOARD

SYM SYMMETRICAL

SYS SYSTEM

TEL TELEPHONE

TEL/DAT TELEPHONE/DATA

TERM TERMINAL

TL TWIST LOCK

TP TAMPER PROOF

T-STAT THERMOSTAT

TTC TELEPHONE TERMINAL

CABINET

TV TELEVISION

TVTC TELEVISION TERMINAL

CABINET

TYP TYPICAL

UC UNDER COUNTER

UE UNDERGROUND ELECTRICAL

UG UNDERGROUND

UH UNIT HEATER

UT UNDERGROUND TELEPHONE

UTIL UTILITY

UV ULTRAVIOLET

V VOLT

VA VOLT-AMPERES

VDT VIDEO DISPLAY TERMINAL

VERT VERTICAL

VFD VARIABLE FREQUENCY DRIVE

VOL VOLUME

W WATT

W/ WITH

WG WIRE GUARD

WH WATER HEATER

W/O WITHOUT

WP WEATHERPROOF

XFMR TRANSFORMER

XFR TRANSFER

∠ ANGLE

@ AT

▲ DELTA

' FEET

" INCHES

# NUMBER

Ø PHASE

C CENTER LINE

P PLATE

EXIT LIGHT, WALL-MOUNTED,

SHADING AND ARROWS INDICATE

FACES AND DIRECTION

WALL-MOUNTED FIXTURES, TYPICAL

EXW1

LIGHTING FIXTURE TAG DESCRIPTORS:

TOP VALUE: FIXTURE TYPE ID.

BOTTOM VALUE, NUMBER: CIRCUIT NUMBER, REFER TO

DRAWINGS FOR PANEL.

BOTTOM VALUE, LOWERCASE LETTER: SWITCH DESIGNATION.

ABSENCE OF A SWITCH ID INDICATES FIXTURE IS CONTROLLED BY THE

ONLY SWITCH IN THE SPACE.

"x" IN PLACE OF THE SWITCH ID INDICATES NIGHT LIGHT, UNSWITCHED.

S3

1d

ELECTRIC STRIKE

MAGNETIC LOCK

COMBINATION LOCK

DOOR CONTACT

CARD READER

SECURITY KEYPAD

MOTION DETECTOR

NURSE CALL EMERG. STATION

NURSE CALL CODE BLUE STATION

NURSE CALL STAFF STATION

NURSE CALL PATIENT STATION

NURSE CALL DOME LIGHT

(1-COLOR)

TELEPHONE OUTLET

VOICE/DATA OUTLET

DOOR BELL

DOOR BUZZER

DOOR CHIME

DOOR SIGNAL

VOLUME CONTROL

MICROPHONE OUTLET

1V2D

CATV OUTLET

TV OUTLET

NURSE CALL DOME LIGHT

(4-COLORS)

NURSE CALL DOME LIGHT

(2-COLORS)

AUTO DOOR PUSH PAD

EMERGENCY LIGHTING UNIT, WALL-

MOUNTED, REMOTE BATTERY

EMERGENCY LIGHTING UNIT, WALL-

MOUNTED, INTEGRAL BATTERY

EMERGENCY LIGHTING UNIT, CEILING-

MOUNTED, INTEGRAL BATTERY

EMERGENCY LIGHTING UNIT, CEILING-

MOUNTED, REMOTE BATTERY

LIGHTING FIXTURES, TYPICAL,

RECTANGULAR FILLED CIRCLES

INDICATE RECESSED, OPEN CIRCLES

INDICATE SURFACE

DIAGONAL LINE INDICATES LENSED

OUTER DOTS INDICATE SUSPENDED

LIGHTING FIXTURES, TYPICAL, ROUND

CENTER DOT INDICATES PENDANT

DIAGONAL LINE INDICATES LENSED

CHEVRON INDICATES WALL WASH

STRIP FIXTURE

DIRECTIONAL LIGHT, TRACK, FLOOD

EXIT LIGHT, CEILING-MOUNTED,

SHADING AND ARROWS INDICATE

FACES AND DIRECTION

LINEAR LIGHT, TAPE LIGHT

EXIT/ELU COMBO

DIAGONAL HATCH INDICATES LIGHT

ON A CRITICAL CIRCUIT

SOLID HATCH INDICATES LIGHT ON

AN EMERGENCY OR LIFE SAFETY

CIRCUIT

POLE/AREA LIGHTS

POST-TOP AREA LIGHT

BOLLARD LIGHT

SPRINKLER FLOW SWITCH

SPRINKLER VALVE TAMPER SWITCH

DUCT SMOKE DETECTOR

CEILING SMOKE DETECTOR

THERMAL DETECTOR

ELECTRICAL SYMBOL LEGEND

# OF COLORS.

* NOTE *

ALL GENERAL NOTES ON THIS SHEET ARE TO BE APPLIED TO ALL OTHER DRAWINGS

IN THIS SET. THE SYMBOLS AND ABBREVIATIONS SHOWN ON THIS SHEET MAY OR

MAY NOT BE USED IN THIS SET OF DRAWINGS.

EM

G

FI

G

FI

W P

U

SB DUPLEX RECEPTACLE W/ USB PORTS

TP

TAMPER-PROOF DUPLEX

RECEPTACLE

GENERAL PROJECT NOTES

A CONDUCTORS OPERATING AT 50 VOLTS OR GREATER SHALL BE IN RACEWAY.

RACEWAY WITHIN THE STRUCTURE ABOVE THE FLOOR SLAB SHALL BE METAL.

RACEWAY BELOW THE FLOOR SLAB AND UNDERGROUND RACEWAY OUTSIDE

THE STRUCTURE SHALL BE PVC.

B LOW VOLTAGE CABLES OR CONDUCTORS OPERATING AT LESS THAN 50 VOLTS

SHALL BE IN METAL RACEWAY WHERE INSTALLED WITHIN WALLS OR INACCESSIBLE

SPACES. LOW VOLTAGE CABLES MAY BE RUN IN CABLE TRAY WHERE NOTED.

LOW VOLTAGE CABLES MAY BE RUN IN CABLE SUPPORT HOOKS ABOVE

ACCESSIBLE CEILINGS WHERE NOTED. LOW VOLTAGE CABLE SHALL BE PLENUM

RATED IN PLENUM SPACES.

C COORDINATE LOCATIONS OF DEVICES WITH ARCHITECTURAL ELEVATIONS AND

DETAILS. ARCHITECTURAL ELEVATIONS AND DETAILS TAKE PRECEDENCE OVER

LOCATIONS SHOWN ON ELECTRICAL DRAWINGS.

D PROVIDE CABLE OR CONDUIT AND WIRE AS REQUIRED TO ACHIEVE CIRCUITING

SHOWN. SIZE CONDUCTORS PER NEC AMPACITY AND WIRE FILL CRITERIA.

PROVIDE DEDICATED NEUTRAL AND GROUND CONDUCTORS FOR CIRCUITING,

UNLESS NOTED OTHERWISE. INCREASE BRANCH CIRCUIT AND/OR FEEDER

CONDUCTORS INCLUDING EQUIPMENT GROUNDING CONDUCTORS

PROPORTIONALLY FOR NO MORE THAN 3% VOLTAGE DROP ON BRANCH

CIRCUITS AND 2% ON FEEDERS.

E IT IS THE RESPONSIBILITY OF THIS CONTRACTOR TO COORDINATE INSTALLATION

OF ELECTRICAL SYSTEMS AND THOSE REQUIRING ELECTRICAL CONNECTIONS TO

MAINTAIN NEC REQUIRED CLEARANCES, INCLUDED BY NOT LIMITED TO AREAS

ABOVE ACCESSIBLE CEILINGS.

F COORDINATE WITH OTHER TRADES FOR PROPER INSTALLATION OF ELECTRICAL

EQUIPMENT. CONSULT THE DRAWINGS OF OTHER TRADES OR CRAFTS TO AVOID

CONFLICTS WITH EQUIPMENT, ETC. CONFLICTS SHALL BE RESOLVED PRIOR TO

ROUGH-IN AND AT NO ADDITIONAL COST TO THE OWNER.

G LEAVE THE SITE CLEAN AND READY FOR OCCUPANCY. REMOVE DIRT, DEBRIS,

EMPTY CARTONS, TOOLS, CONDUIT AND WIRE SCRAPS AND MISCELLANEOUS

SPARE EQUIPMENT AND MATERIALS USED IN THIS DIVISION OF THE WORK DURING

CONSTRUCTION. COMPONENTS SHALL BE FREE OF DUST, GRIT AND FOREIGN

MATERIALS AND LEFT AS NEW BEFORE FINAL ACCEPTANCE OF WORK.

H THE SYMBOLS AND ABBREVIATIONS SHOWN ON THIS SHEET MAY OR MAY NOT BE

USED IN THIS SET OF DRAWINGS.

I PERFORM WORK TO COMPLY WITH THE STANDARD PRACTICES FOR GOOD

WORKMANSHIP PUBLISHED BY NATIONAL ELECTRICAL CONTRACTORS

ASSOCIATION (NECA). COMPLY WITH THE LATEST ENFORCED EDITION OF THE

NATIONAL ELECTRICAL CODE (NEC), LOCAL CODES, AMENDMENTS, AND

ORDINANCES.

J FIELD COORDINATE FINAL MECHANICAL AND EQUIPMENT LOCATIONS ALONG

WITH CONNECTION REQUIREMENTS AND CONTROL WIRING PRIOR TO

ROUGH-IN. ADJUST CORRESPONDING CIRCUIT BREAKER RATINGS AND BRANCH

CIRCUITING ACCORDINGLY.

K ELECTRICAL WORK SHALL BE PERFORMED UNDER THE SUPERVISION OF A

LICENSED MASTER ELECTRICIAN. PROCURE PERMITS AND LICENSES AND PAY FEES

ASSOCIATED WITH THIS WORK.

L MATERIALS FURNISHED FOR THIS PROJECT SHALL BE NEW, COMMERCIAL GRADE,

FREE OF DEFECTS, AND LISTED BY A NATIONALLY RECOGNIZED TESTING

LABORATORY UNO.

M PROVIDE COMPLETE OPERATION & MAINTENANCE MANUAL INCLUDING

APPROVED SUBMITTAL DRAWINGS, WARRANTY INFORMATION FOR PRODUCT

SUPPLIED, AND MANUFACTURES OPERATION AND MAINTENANCE INSTRUCTIONS.

N THE CONTRACTOR IS RESPONSIBLE FOR MAKING FINAL WIRING TERMINATIONS

TO PRE-INSTALLED RECEPTACLES IN OFFICE FURNITURE. CONTRACTOR IS

RESPONSIBLE FOR WIRING AND INSTALLING VOICE/DATA DEVICES IN OFFICE

FURNITURE. COORDINATE PLACEMENT OF DEVICES WITH FURNITURE LAY-OUT.

O CONDUIT AND WIRE SHALL NOT BE INSTALLED BELOW FLOOR SLAB UNLESS

INDICATED ON PLAN BY DASHED CONDUIT.

P CONTRACTOR SHALL BE RESPONSIBLE FOR WIRING ELECTRICAL ITEMS SHOWN

ON DRAWINGS.

Q TV OUTLETS, VOLUME CONTROLS, NURSE CALL DOME LIGHTS, NURSE CALL

DEVICES, TELEPHONE OUTLETS, DATA OUTLETS, AND FIRE ALARM DEVICES SHALL

CONSIST OF A DATA DEVICE BACK BOX WTIH CONDUIT STUBBED ABOVE THE

ACCESSIBLE CEILING, SEE STUB UP DETAIL.VERIFY SIZE OF BACK BOX REQUIRED

WITH DEVICE TO BE INSTALLED. LOCATE BACK BOXES 6" FROM ADJACENT

POWER RECEPTACLE INTENDED FOR COMPUTER USE. COORDINATE BOX

REQUIREMENTS INCLUDING SIZE, LOCATION AND CONDUIT SIZE, ROUTE AND

TERMINATION LOCATION WITH THE EQUIPMENT SUPPLIER PRIOR TO ROUGHING

IN. COORDINATE CIRCUITRY/WIRE/CABLE REQUIREMENTS WITH THE RESPECTIVE

EQUIPMENT SUPPLIER/SPECIFIER.

R FURNISH AND INSTALL CONDUIT FROM BACK BOXES FOR THE FOLLOWING

DEVICES INTO THE ACCESSIBLE CEILING SPACE IN THE CORRIDOR, UNLESS NOTED

OTHERWISE:

1 / 2 " C T V O U T L E T S 1 / 2 " C V O L U M E C O N T R O L S

3/4"C DOOR SECURITY DEVICES (CARD READERS, DOOR STRIKES ETC..)

1 / 2 " C N U R S E C A L L D O M E L I G H T S 3 / 4 " C N U R S E C A L L D E V I C E S 3 / 4 " C T E L E P H O N E O U T L E T S 3 / 4 " C I N F O R M A T I O N O U T L E T S 3 / 4 " C F I R E A L A R M D E V I C E S

B R A D E N

S .

C O X

6201070323

NO.

ENGINEER

S T

A

T E

O F M I C

H I

G A

N

R E

E N

I G

N

E L

ANOISSEFORP

D

E S

N E

C I

L

AREA - A

AREA - B

AREA - C

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

DWG. ___ OF 145

7GAE PROJECT NO.: 219123

Sprinkler:

600 E. Michigan Avenue, Suite B

Kalamazoo, MI 49007

P: 269.927.0144 www.7GenAE.com

2850 Eisenhower Ave, Suite 310

Alexandria, VA 22314

P: 202.617.8485 www.alliance.us.com

100% BID DOCUMENTS APRIL 6, 2023

ELECTRICAL GENERAL INFO. &

SYMBOLS LEGEND

UPGRADE PRIMARY CARE

ANN ARBOR VAMC

506-20-103

1E

PROJECT DIRECTOR

APRIL 6, 2023 BC RM

100% BID

DOCUMENTS

E001

FULLY SPRINKLERED

GENERAL FIRE PROTECTION NOTES

A PENETRATIONS IN WALLS REQUIRING PROTECTED OPENINGS MUST BE

FIRESTOPPED WITH AN APPROVED MATERIAL.

B CONDUITS MAY PENETRATE WALLS OR PARTITIONS, PROVIDED THEY ARE

FIRESTOPPED.

C OPENINGS FOR STEEL ELECTRICAL BOXES NOT EXCEEDING 16 SQUARE INCHES

ARE PERMITTED PROVIDED OPENINGS DO NOT AGGREGATE MORE THAN 100

SQUARE INCHES FOR ANY 100 SQUARE FEET OF WALL OR PARTITION.

D OUTLET BOXES ON OPPOSITE SIDES OF WALLS OR PARTITIONS MUST BE

SEPARATED BY A HORIZONTAL DISTANCE OF 24 INCHES.

E LIGHT FIXTURES AND OTHER APPARATUS SUPPORTED BY THE ACOUSTICAL

CEILING GRID MUST MEET THE REQUIREMENTS OF NEC SECTION 410.16, MEANS

OF SUPPORT.

F RECESSED LIGHTING FIXTURES INSTALLED IN FIRE RATED CEILING ASSEMBLIES

SHALL BE FIRE RATED FIXTURES BEARING THE UL FIRE RATED LABEL. FIXTURES SHALL

BE INSTALLED IN ACCORDANCE WITH THE UL FIRE RESISTANCE DIRECTORY, AND

SHALL INCLUDE A FIRE RATED ENCLOSURE INSTALLED OVER THE FIXTURE THAT

MEETS THE REQUIREMENTS OF THE UL FIRE RESISTANCE DIRECTORY.

Revisions: Date:

4/7/23

1E-K

1E-J

1E-J

1E-H

1E-H

1E-G

1E-G

1E-F

1E-F

1E-E

1E-E

1E-10 1E-10

1E-9 1E-9

1E-8 1E-8

1E-7 1E-7

1E-6 1E-6

1E-5 1E-5

1E-4 1E-4

1E-3.8 1E-3.8

1E-3.6 1E-3.6

1E-3.5 1E-3.5

1E-3.4 1E-3.4 1E-3.3

1E-3.3

1E-3 1E-3

S

2 3

2 3

2 3

2 3

2 3

2 3

2 3

2 3

2 3 2 3 2 3 2 3

2 3 2 3

2 3

2 3 2 3 2 3

2 3 2 3 2 3

2 3

2 3

2 3

2 3 3

2 3

2 3 2 3

2 3

2 3

32 32

32 32

32 32

32 32 2 3

2 3

2 3

2 3

2 3

2 3

2 3

2 3

2 3

2 3

(E) 1-AH-9

B R A D E N

S .

C O X

6201070323

NO.

ENGINEER

S T

A

T E

O F M I C

H I

G A

N

R E

E N

I G

N

E L

ANOISSEFORP

D

E S

N E

C I

L

AREA - A

AREA - B

AREA - C

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

DWG. ___ OF 145

7GAE PROJECT NO.: 219123

Sprinkler:

600 E. Michigan Avenue, Suite B

Kalamazoo, MI 49007

P: 269.927.0144 www.7GenAE.com

2850 Eisenhower Ave, Suite 310

Alexandria, VA 22314

P: 202.617.8485 www.alliance.us.com

100% BID DOCUMENTS APRIL 6, 2023

FIRST FLOOR ELECTRICAL

DEMOLITION PLAN

UPGRADE PRIMARY CARE

ANN ARBOR VAMC

506-20-103

1E

PROJECT DIRECTOR

APRIL 6, 2023 BC RM

100% BID

DOCUMENTS

ED101

FULLY SPRINKLERED

GENERAL ELEC. DEMO NOTES

A SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR

PHASES OF DEMOLITION AND CONSTRUCTION. COORDINATE

WITH GENERAL CONSTRUCTION.

B DISCONNECT AND REMOVE ALL ELECTRICAL DEVICES AND

LIGHTING FIXTURES, WHETHER SHOWN OR NOT, IN DEMOLITION

AREAS UNLESS NOTED OTHERWISE.

C DISCONNECT AND REMOVE ALL ELECTRICAL DEVICES IN WALLS

TO BE DEMOLISHED. WALLS TO BE DEMOLISHED ARE SHOWN

DASHED. DISCONNECT AND REMOVE ASSOCIATED CONDUIT

AND WIRE BACK TO LAST REMAINING DEVICE. FURNISH AND

INSTALL CONDUIT AND WIRE AS NECESSARY FOR CONTINUITY OF

CIRCUIT(S) TO ANY EXISTING DEVICES TO REMAIN. COORDINATE

AND VERIFY REQUIREMENTS WITH NEW WORK IN AREA.

D FURNISH AND INSTALL CONDUIT AND WIRE AS NECESSARY FOR

CONTINUITY OF ANY FEEDERS OR BRANCH CIRCUITS

ORIGINATING OUTSIDE THE DEMOLITION AREA THAT SERVES ANY

ELECTRICAL EQUIPMENT OR DEVICES TO REMAIN AFTER

DEMOLITION. MODIFY OR REPLACE AS REQUIRED.

E FURNISH AND INSTALL CONDUIT AND/OR

COMMUNICATIONS/DATA WIRING AS NECESSARY FOR

CONTINUITY OF ANY WIRING ORIGINATING OUTSIDE THE

DEMOLITION AREA THAT SERVES ANY COMMUNICATIONS/DATA

EQUIPMENT OR DEVICES TO REMAIN AFTER DEMOLITION.

MODIFY OR REPLACE AS REQUIRED.

F DISCONNECT AND REMOVE LIGHT SWITCHES IN DEMOLITION

AREAS AS NECESSARY TO ACCOMMODATE NEW DOOR

CONFIGURATIONS.

G DISCONNECT AND REMOVE ANY EXISTING ELECTRICAL DEVICES

AND BACK BOXES AS NECESSARY WHERE NEW WALL

CONSTRUCTION WILL INTERSECT AN EXISTING WALL. FURNISH

AND INSTALL CONDUIT AND WIRE AS REQUIRED FOR

CONTINUITY OF CIRCUIT(S).

H FURNISH AND INSTALL BLANK COVER PLATES OVER ALL EXISTING

UNUSED OPENINGS.

NORTH

SCALE: 1/8" = 1'-0"

FIRST FLOOR ELECTRICAL DEMOLITION PLAN

KEYNOTES

1 EXISTING RECEPTACLE SHALL REMAIN, REFER TO THE POWER

PLAN FOR THE NEW/REVISED CIRCUITING INFORMATION.

2 DEMOLISH LIGHT FIXTURES, SWITCHES AND ASSOCIATED

UNUSED BRANCH CIRCUITRY, FIELD VERIFY QUANTITIES AND

REQUIREMENTS.

3 DEMOLISH RECEPTACLES AND ELECTRICAL DEVICES, UNLESS

NOTED OTHERWISE, AND ASSOCIATED UNUSED BRANCH

CIRCUITRY, FIELD VERIFY QUANTITIES AND REQUIREMENTS.

4 DEMOLISH POWER, ASSOCIATED CIRCUITRY AND CONTROL

CABLING FOR THE LIFT DEMOLITION. FIELD VERIFY THE

REQUIREMENTS.

5 FIELD VERIFY THE LOCATION AND DEMOLISH THE EXISTING

DISCONNECT SERVING THE EXISTING FAN IN AHU-9. DEMOLISH

THE ASSOCIATED CONDUIT AND WIRING BACK TO THE

SOURCE. DEMOLISH THE ASSOCIATED CIRCUIT BREAKER, THE

SPACE SHALL BE REUSED FOR THE NEW FAN, SF-9, CIRCUIT

BREAKER.

1E-J

1E-J

1E-H

1E-H

1E-G

1E-G

1E-F

1E-F

1E-E

1E-E

1E-5 1E-5

1E-4 1E-4

1E-3.8 1E-3.8

1E-3.6 1E-3.6

1E-3.5 1E-3.5

1E-3.4 1E-3.4

1E-3.3 1E-3.3

1E-3 1E-3

S

1 DEMOLISHED

RECEPTACLE,

TYPICAL

DEMOLISHED

LIGHT FIXTURE,

TYPICAL

2 3

2 3

2 3

2 3

2 3

2 3

2 3

2 32 32

2 3

2 3 2 3

2 3

B R A D E N

S .

C O X

6201070323

NO.

ENGINEER

S T

A

T E

O F M I C

H I

G A

N

R E

E N

I G

N

E L

ANOISSEFORP

D

E S

N E

C I

L

AREA - A

AREA - B

AREA - C

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

DWG. ___ OF 145

7GAE PROJECT NO.: 219123

Sprinkler:

600 E. Michigan Avenue, Suite B

Kalamazoo, MI 49007

P: 269.927.0144 www.7GenAE.com

2850 Eisenhower Ave, Suite 310

Alexandria, VA 22314

P: 202.617.8485 www.alliance.us.com

100% BID DOCUMENTS APRIL 6, 2023

ENLARGED ELECTRICAL

DEMOLITION PLAN - AREA A

UPGRADE PRIMARY CARE

ANN ARBOR VAMC

506-20-103

1E

PROJECT DIRECTOR

APRIL 6, 2023 BC RM

100% BID

DOCUMENTS

ED101A

FULLY SPRINKLERED

NORTH

SCALE: 1/4" = 1'-0"

ENLARGED ELECTRICAL DEMOLITION PLAN - AREA A

GENERAL ELEC. DEMO NOTES

A SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR

PHASES OF DEMOLITION AND CONSTRUCTION. COORDINATE

WITH GENERAL CONSTRUCTION.

B DISCONNECT AND REMOVE ALL ELECTRICAL DEVICES AND

LIGHTING FIXTURES, WHETHER SHOWN OR NOT, IN DEMOLITION

AREAS UNLESS NOTED OTHERWISE.

C DISCONNECT AND REMOVE ALL ELECTRICAL DEVICES IN WALLS

TO BE DEMOLISHED. WALLS TO BE DEMOLISHED ARE SHOWN

DASHED. DISCONNECT AND REMOVE ASSOCIATED CONDUIT

AND WIRE BACK TO LAST REMAINING DEVICE. FURNISH AND

INSTALL CONDUIT AND WIRE AS NECESSARY FOR CONTINUITY OF

CIRCUIT(S) TO ANY EXISTING DEVICES TO REMAIN. COORDINATE

AND VERIFY REQUIREMENTS WITH NEW WORK IN AREA.

D FURNISH AND INSTALL CONDUIT AND WIRE AS NECESSARY FOR

CONTINUITY OF ANY FEEDERS OR BRANCH CIRCUITS

ORIGINATING OUTSIDE THE DEMOLITION AREA THAT SERVES ANY

ELECTRICAL EQUIPMENT OR DEVICES TO REMAIN AFTER

DEMOLITION. MODIFY OR REPLACE AS REQUIRED.

E FURNISH AND INSTALL CONDUIT AND/OR

COMMUNICATIONS/DATA WIRING AS NECESSARY FOR

CONTINUITY OF ANY WIRING ORIGINATING OUTSIDE THE

DEMOLITION AREA THAT SERVES ANY COMMUNICATIONS/DATA

EQUIPMENT OR DEVICES TO REMAIN AFTER DEMOLITION.

MODIFY OR REPLACE AS REQUIRED.

F DISCONNECT AND REMOVE LIGHT SWITCHES IN DEMOLITION

AREAS AS NECESSARY TO ACCOMMODATE NEW DOOR

CONFIGURATIONS.

G DISCONNECT AND REMOVE ANY EXISTING ELECTRICAL DEVICES

AND BACK BOXES AS NECESSARY WHERE NEW WALL

CONSTRUCTION WILL INTERSECT AN EXISTING WALL. FURNISH

AND INSTALL CONDUIT AND WIRE AS REQUIRED FOR

CONTINUITY OF CIRCUIT(S).

H FURNISH AND INSTALL BLANK COVER PLATES OVER ALL EXISTING

UNUSED OPENINGS.

KEYNOTES

1 EXISTING RECEPTACLE SHALL REMAIN, REFER TO THE POWER

PLAN FOR THE NEW/REVISED CIRCUITING INFORMATION.

2 DEMOLISH LIGHT FIXTURES, SWITCHES AND ASSOCIATED

UNUSED BRANCH CIRCUITRY, FIELD VERIFY QUANTITIES AND

REQUIREMENTS.

3 DEMOLISH RECEPTACLES AND ELECTRICAL DEVICES, UNLESS

NOTED OTHERWISE, AND ASSOCIATED UNUSED BRANCH

CIRCUITRY, FIELD VERIFY QUANTITIES AND REQUIREMENTS.

4 DEMOLISH POWER, ASSOCIATED CIRCUITRY AND CONTROL

CABLING FOR THE LIFT DEMOLITION. FIELD VERIFY THE

REQUIREMENTS.

1E-J

1E-J

1E-H

1E-H

1E-G

1E-G

1E-F

1E-F

1E-E

1E-E

1E-7 1E-7

1E-6 1E-6

1E-5 1E-5

S

DEMOLISHED

RECEPTACLE,

TYPICAL

DEMOLISHED

LIGHT FIXTURE,

TYPICAL

2 3

2 3

2 32 32

2 3 2 3

2 3

2 3

2 3

2 3

2 3

2 3 2 3

2 32 3

2 3

2 3 2 3

2 3

2 3 2 3

2 3

2 3 2 3

2 3

2 3

2 3

2 3

2 3

2 3

2 3

2 3

2 3

2 3

B R A D E N

S .

C O X

6201070323

NO.

ENGINEER

S T

A

T E

O F M I C

H I

G A

N

R E

E N

I G

N

E L

ANOISSEFORP

D

E S

N E

C I

L

AREA - A

AREA - B

AREA - C

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

DWG. ___ OF 145

7GAE PROJECT NO.: 219123

Sprinkler:

600 E. Michigan Avenue, Suite B

Kalamazoo, MI 49007

P: 269.927.0144 www.7GenAE.com

2850 Eisenhower Ave, Suite 310

Alexandria, VA 22314

P: 202.617.8485 www.alliance.us.com

100% BID DOCUMENTS APRIL 6, 2023

ENLARGED ELECTRICAL

DEMOLITION PLAN - AREA B

UPGRADE PRIMARY CARE

ANN ARBOR VAMC

506-20-103

1E

PROJECT DIRECTOR

APRIL 6, 2023 BC RM

100% BID

DOCUMENTS

ED101B

FULLY SPRINKLERED

NORTH

SCALE: 1/4" = 1'-0"

ENLARGED ELECTRICAL DEMOLITION PLAN - AREA B

GENERAL ELEC. DEMO NOTES

A SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR

PHASES OF DEMOLITION AND CONSTRUCTION. COORDINATE

WITH GENERAL CONSTRUCTION.

B DISCONNECT AND REMOVE ALL ELECTRICAL DEVICES AND

LIGHTING FIXTURES, WHETHER SHOWN OR NOT, IN DEMOLITION

AREAS UNLESS NOTED OTHERWISE.

C DISCONNECT AND REMOVE ALL ELECTRICAL DEVICES IN WALLS

TO BE DEMOLISHED. WALLS TO BE DEMOLISHED ARE SHOWN

DASHED. DISCONNECT AND REMOVE ASSOCIATED CONDUIT

AND WIRE BACK TO LAST REMAINING DEVICE. FURNISH AND

INSTALL CONDUIT AND WIRE AS NECESSARY FOR CONTINUITY OF

CIRCUIT(S) TO ANY EXISTING DEVICES TO REMAIN. COORDINATE

AND VERIFY REQUIREMENTS WITH NEW WORK IN AREA.

D FURNISH AND INSTALL CONDUIT AND WIRE AS NECESSARY FOR

CONTINUITY OF ANY FEEDERS OR BRANCH CIRCUITS

ORIGINATING OUTSIDE THE DEMOLITION AREA THAT SERVES ANY

ELECTRICAL EQUIPMENT OR DEVICES TO REMAIN AFTER

DEMOLITION. MODIFY OR REPLACE AS REQUIRED.

E FURNISH AND INSTALL CONDUIT AND/OR

COMMUNICATIONS/DATA WIRING AS NECESSARY FOR

CONTINUITY OF ANY WIRING ORIGINATING OUTSIDE THE

DEMOLITION AREA THAT SERVES ANY COMMUNICATIONS/DATA

EQUIPMENT OR DEVICES TO REMAIN AFTER DEMOLITION.

MODIFY OR REPLACE AS REQUIRED.

F DISCONNECT AND REMOVE LIGHT SWITCHES IN DEMOLITION

AREAS AS NECESSARY TO ACCOMMODATE NEW DOOR

CONFIGURATIONS.

G DISCONNECT AND REMOVE ANY EXISTING ELECTRICAL DEVICES

AND BACK BOXES AS NECESSARY WHERE NEW WALL

CONSTRUCTION WILL INTERSECT AN EXISTING WALL. FURNISH

AND INSTALL CONDUIT AND WIRE AS REQUIRED FOR

CONTINUITY OF CIRCUIT(S).

H FURNISH AND INSTALL BLANK COVER PLATES OVER ALL EXISTING

UNUSED OPENINGS.

KEYNOTES

1 EXISTING RECEPTACLE SHALL REMAIN, REFER TO THE POWER

PLAN FOR THE NEW/REVISED CIRCUITING INFORMATION.

2 DEMOLISH LIGHT FIXTURES, SWITCHES AND ASSOCIATED

UNUSED BRANCH CIRCUITRY, FIELD VERIFY QUANTITIES AND

REQUIREMENTS.

3 DEMOLISH RECEPTACLES AND ELECTRICAL DEVICES, UNLESS

NOTED OTHERWISE, AND ASSOCIATED UNUSED BRANCH

CIRCUITRY, FIELD VERIFY QUANTITIES AND REQUIREMENTS.

1E-J

1E-J

1E-H

1E-H

1E-G

1E-G

1E-F

1E-F

1E-E

1E-E

1E-11 1E-11

1E-10 1E-10

1E-9 1E-9

1E-8 1E-8

1E-7 1E-7

S

DEMOLISHED

LIGHT FIXTURE,

TYPICAL

DEMOLISHED

RECEPTACLE,

TYPICAL

1 2 1 2

1 2

1 2

B R A D E N

S .

C O X

6201070323

NO.

ENGINEER

S T

A

T E

O F M I C

H I

G A

N

R E

E N

I G

N

E L

ANOISSEFORP

D

E S

N E

C I

L

AREA - A

AREA - B

AREA - C

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

DWG. ___ OF 145

7GAE PROJECT NO.: 219123

Sprinkler:

600 E. Michigan Avenue, Suite B

Kalamazoo, MI 49007

P: 269.927.0144 www.7GenAE.com

2850 Eisenhower Ave, Suite 310

Alexandria, VA 22314

P: 202.617.8485 www.alliance.us.com

100% BID DOCUMENTS APRIL 6, 2023

ENLARGED ELECTRICAL

DEMOLITION PLAN - AREA C

UPGRADE PRIMARY CARE

ANN ARBOR VAMC

506-20-103

1E

PROJECT DIRECTOR

APRIL 6, 2023 BC RM

100% BID

DOCUMENTS

ED101C

FULLY SPRINKLERED

NORTH

SCALE: 1/4" = 1'-0"

ENLARGED ELECTRICAL DEMOLITION PLAN - AREA C

GENERAL ELEC. DEMO NOTES

A SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR

PHASES OF DEMOLITION AND CONSTRUCTION. COORDINATE

WITH GENERAL CONSTRUCTION.

B DISCONNECT AND REMOVE ALL ELECTRICAL DEVICES AND

LIGHTING FIXTURES, WHETHER SHOWN OR NOT, IN DEMOLITION

AREAS UNLESS NOTED OTHERWISE.

C DISCONNECT AND REMOVE ALL ELECTRICAL DEVICES IN WALLS

TO BE DEMOLISHED. WALLS TO BE DEMOLISHED ARE SHOWN

DASHED. DISCONNECT AND REMOVE ASSOCIATED CONDUIT

AND WIRE BACK TO LAST REMAINING DEVICE. FURNISH AND

INSTALL CONDUIT AND WIRE AS NECESSARY FOR CONTINUITY OF

CIRCUIT(S) TO ANY EXISTING DEVICES TO REMAIN. COORDINATE

AND VERIFY REQUIREMENTS WITH NEW WORK IN AREA.

D FURNISH AND INSTALL CONDUIT AND WIRE AS NECESSARY FOR

CONTINUITY OF ANY FEEDERS OR BRANCH CIRCUITS

ORIGINATING OUTSIDE THE DEMOLITION AREA THAT SERVES ANY

ELECTRICAL EQUIPMENT OR DEVICES TO REMAIN AFTER

DEMOLITION. MODIFY OR REPLACE AS REQUIRED.

E FURNISH AND INSTALL CONDUIT AND/OR

COMMUNICATIONS/DATA WIRING AS NECESSARY FOR

CONTINUITY OF ANY WIRING ORIGINATING OUTSIDE THE

DEMOLITION AREA THAT SERVES ANY COMMUNICATIONS/DATA

EQUIPMENT OR DEVICES TO REMAIN AFTER DEMOLITION.

MODIFY OR REPLACE AS REQUIRED.

F DISCONNECT AND REMOVE LIGHT SWITCHES IN DEMOLITION

AREAS AS NECESSARY TO ACCOMMODATE NEW DOOR

CONFIGURATIONS.

G DISCONNECT AND REMOVE ANY EXISTING ELECTRICAL DEVICES

AND BACK BOXES AS NECESSARY WHERE NEW WALL

CONSTRUCTION WILL INTERSECT AN EXISTING WALL. FURNISH

AND INSTALL CONDUIT AND WIRE AS REQUIRED FOR

CONTINUITY OF CIRCUIT(S).

H FURNISH AND INSTALL BLANK COVER PLATES OVER ALL EXISTING

UNUSED OPENINGS.

KEYNOTES

1 DEMOLISH LIGHT FIXTURES, SWITCHES AND ASSOCIATED

UNUSED BRANCH CIRCUITRY, FIELD VERIFY QUANTITIES AND

REQUIREMENTS.

2 DEMOLISH RECEPTACLES AND ELECTRICAL DEVICES, UNLESS

NOTED OTHERWISE, AND ASSOCIATED UNUSED BRANCH

CIRCUITRY, FIELD VERIFY QUANTITIES AND REQUIREMENTS.

DTS

DTS

R L

DTS

DTS

RL4 RL4

DTS

DTS

R L

R L

R L

R L

R L

R L

R L

R L

R L

R L

R L

DTS

R L

R L

OS

OS

R L

R L

DTS

RL4

R L

R L

R L

R L

R L

R L

R L

D T

S

RL4

RL4

RL4

OS

R L

R L

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS OS OS OS

OS

OS

OS

OS

OS

OS

OS

OS

RL4

OS

OS

OS

OS

R L

R L

R L

R L

R L

R L

R L

R L

R L

R L

R L

R L

R L

R L

R L

R L

R

L

R L

R L

OS

DTS

R L

DTS

PROCEDURE 3

D129

PATIENT TOILET

D130

TOILET

D163

CORRIDOR

D134

CLEAN SUPPLY

D160 PASSAGE

C1-21

EXAM/ CONSULT

D128

EXAM/ CONSULT.

D126

PATIENT TOILET

D131

CORRIDOR

D122

PROCEDURE 2

D112

PATIENT TOILET

D113

PATIENT TOILET

D110

EXAM/ CONSULT.

D116

EXAM/ CONSULT.

D114

PROCEDURE 1

D109

EXAM/ CONSULT.

D104

CORRIDOR

D135A

INTAKE 1

D102INTAKE 2

D103

TEAM 1 WORK

ROOM

D148

HEIGHT &

WEIGHT

D105 PRIVATE VIRTUAL

D147

EXAM/ CONSULT.

D106

EXAM/ CONSULT.

D107

EXAM/ CONSULT.

D115

EXAM/ CONSULT.

D119

MED ROOM

D121

EXAM/ CONSULT.

D123

EXAM/ CONSULT.

D125

SOILED UTILITY

D127

OVERFLOW

STAFF WORK

ROOM

D159

TOILET

D158

PROCEDURE 6

D156

EXAM/ CONSULT.

D154

EXAM/ CONSULT.

D152

HOUSEKEEPING

D157

CORRIDOR

D136

EXAM/ CONSULT.

D155

EXAM/ CONSULT.

D153

MED ROOM

D151

EXAM/ CONSULT.

D149

EXAM/ CONSULT.

D145

EXAM/ CONSULT.

D143

EXAM/ CONSULT.

D141

EXAM/ CONSULT.

D144

EXAM/ CONSULT.

D142

EXAM/ CONSULT.

D140

EXAM/ CONSULT.

D138

HEIGHT &

WEIGHT

D137

EXAM/ CONSULT.

D139

CORRIDOR

D134

PATIENT TOILET

D146

CORRIDOR

D134

CORRIDOR

D135

CORRIDOR

D135

CORRIDOR

D136

TEAM 2 WORK

ROOM

D150

EXAM/ CONSULT.

D117

ELEC

D100A

PATIENT TOILET

D108PT

D111A

CORRIDOR

D134

BREAKROOM/

LOUNGE

D132

BREAKROOM/

LOUNGE

D132

TEAM 2 WORK

ROOM

D150

TELEHEALTH

D111D

STAFF UROLOGY

WORK ROOM

D111B

WAITING AREA

D100

E101B

E101CE101C

E101A

E101BE101B

E101B

E101CE101C

E101A

E101BE101B

B R A D E N

S .

C O X

6201070323

NO.

ENGINEER

S T

A

T E

O F M I C

H I

G A

N

R E

E N

I G

N

E L

ANOISSEFORP

D

E S

N E

C I

L

AREA - A

AREA - B

AREA - C

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

DWG. ___ OF 145

7GAE PROJECT NO.: 219123

Sprinkler:

600 E. Michigan Avenue, Suite B

Kalamazoo, MI 49007

P: 269.927.0144 www.7GenAE.com

2850 Eisenhower Ave, Suite 310

Alexandria, VA 22314

P: 202.617.8485 www.alliance.us.com

100% BID DOCUMENTS APRIL 6, 2023

FIRST FLOOR LIGHTING PLAN UPGRADE PRIMARY CARE

ANN ARBOR VAMC

506-20-103

1E

PROJECT DIRECTOR

APRIL 6, 2023 BC RM

100% BID

DOCUMENTS

E101

FULLY SPRINKLERED

NORTH

SCALE: 1/8" = 1'-0"

FIRST FLOOR LIGHTING PLAN

GENERAL LIGHTING NOTES

A ALL RECESSED LIGHTING FIXTURES IN LAY-IN CEILINGS SHALL BE

INSTALLED WITH 6' LONG (MAXIMUM) FLEXIBLE METAL CONDUIT.

B ALL MOUNTING HEIGHTS FOR LIGHTING FIXTURES ARE TO THE

BOTTOM OF THE FIXTURES UNLESS INDICATED OTHERWISE.

C REFER TO THE LIGHT FIXTURE SCHEDULE AND SEE ARCHITECTURAL

ELEVATIONS FOR MOUNTING HEIGHTS OF LIGHTING FIXTURES.

D REFER TO SECTION 26 0519 FOR MINIMUM CONDUCTOR SIZE

ADJUSTMENTS FOR VOLTAGE DROP.

F WIRE COUNTS FOR CIRCUIT CONDUCTORS ARE NOT SHOWN.

PROVIDE PROPER NUMBER OF CONDUCTORS TO ACHIEVE

CIRCUIT AND SWITCHING CONNECTIONS SHOWN.

J CIRCUIT WIRING IS NOT SHOWN EXCEPT FOR SWITCHING INTENT

OF FIXTURES AND CONTROL OF DEVICES.

K PROVIDE PROPER NUMBER OF CONDUCTORS TO ACHIEVE

CIRCUITING AND SWITCHING SHOWN.

M NIGHT LIGHT (FIXTURES WITH “NL” NOTED ADJACENT) AND

EMERGENCY ILLUMINATION UNITS SHALL BE CONNECTED TO THE

LOCAL NORMAL LIGHTING CIRCUIT AHEAD OF ANY LOCAL

SWITCHING, REFER TO N.E.C. SECTION 700-12(e) FOR

INFORMATION.

N RE-USE EXISTING LIGHTING HOME RUN CIRCUITRY FROM THE

DEMOLISHED FIXTURES. THE CIRCUIT NUMBER SHOWN IS AN

ATTEMPT TO DETERMINE EXISTING CIRCUIT. FIELD VERIFY THE

NEAREST LIGHTING CIRCUIT NUMBER, LOCATION, AVAILABLE

AMPACITY AND CONNECTION LOCATIONS. EXTEND THE

CIRCUITRY AS REQUIRED.

R L

R L

R L

R L

R L

R L

R L

R L

R L

R L

D T

S

RL4

RL4

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

RL4

OS

R L

R L

R L

R L

R L

R L

R L

R L

R L

OS

DTS

EXAM/ CONSULT.

D114

PROCEDURE 1

D109

EXAM/ CONSULT.

D104

CORRIDOR

D135A

INTAKE 1

D102

INTAKE 2

D103

TEAM 1 WORK

ROOM

D148

HEIGHT &

WEIGHT

D105

PRIVATE VIRTUAL

D147

EXAM/ CONSULT.

D106

EXAM/ CONSULT.

D107

EXAM/ CONSULT.

D143

EXAM/ CONSULT.

D141

EXAM/ CONSULT.

D144

EXAM/ CONSULT.

D142

EXAM/ CONSULT.

D140

EXAM/ CONSULT.

D138

HEIGHT &

WEIGHT

D137

EXAM/ CONSULT.

D139

L1-03

CL1-11

LS1-07

CR1-23

R1-22

CR244

CR244

CR222

CR244

CR222

CR244

CR244

CR244

CR244E

CR244E

CR244E

CR244E

CR223E

CR244E

CR244E

CR244CR223

CR223E

CR223

CR223CR223ECR223

CR222E

CR222

CR244E

CR244E

CR244E

CR244E

CR244E

CR244E

CR244E

CR244E

CR244E

CR244E

CR244E

CR244E

CR244E

CR244E

CORRIDOR

D135 CORRIDOR

D136

TEAM 2 WORK

ROOM

D150

CR244E

CR244E

CR244E

CR244E

360 180

L1-01- 22

CR223 CR223

CR223ECR223E

CR223CR223

CR223ECR223E

CR223CR223

CR222CR223E

CR223

CR223E

CR223

CR223E

CR223 CR223

CR223E CR223E

CR223 CR223

CR223E CR223E

CR223 CR223

EXC1

EXC1

EXC1

EXC1

ELEC

D100A

UW3

EXC1

C42

CR223

CR244E

CR244E

CR222

CR222

CR222 CR222E

CR222 CR222

PATIENT TOILET

D108

PT

D111A

STAFF UROLOGY

WORK ROOM

D111B

INTAKE 1

D102

WAITING AREA

D100

DTS

DTS

DTS

D

TS

CR223 CR223

CR223 CR223E CR223

CR223 CR223

CR223 CR223E CR223

LS1-07- 13

L1-01- 22

L1-01- 22

MX448

MX428

MX448

MX448

MX428

MX448E

MX448

MX428

MX448

MX448

MX428

MX448E

MX448

MX448

MX428

MX448

MX448

MX448

MX428

MX448E

MX448

MX448

MX428

MX448

MX448

MX448

MX428

MX448E

MX448

MX428

MX448

MX448

MX448

MX428

MX448E

MX448

MX448

CL1-09- 9

LS1-07- 14

LS1-07- 14

LS1-07- 14

L1-01- 13

LS1-07- 14

LS1-07- 14

LS1-07- 14

LS1-07- 14

LS1-07- 14

LS1-07- 14

LS1-07- 14

LS1-07- 14

LS1-07- 14

L1-01- 22

EXC1

CR222E

MX448

MX448

MX448

MX448

MX448MX448

MX448

MX448

MX448

MX448

CR223

CR223

MX428

L1-04- 144

D

66 77 7

B R A D E N

S .

C O X

6201070323

NO.

ENGINEER

S T

A

T E

O F M I C

H I

G A

N

R E

E N

I G

N

E L

ANOISSEFORP

D

E S

N E

C I

L

AREA - A

AREA - B

AREA - C

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

DWG. ___ OF 145

7GAE PROJECT NO.: 219123

Sprinkler:

600 E. Michigan Avenue, Suite B

Kalamazoo, MI 49007

P: 269.927.0144 www.7GenAE.com

2850 Eisenhower Ave, Suite 310

Alexandria, VA 22314

P: 202.617.8485 www.alliance.us.com

100% BID DOCUMENTS APRIL 6, 2023

ENLARGED LIGHTING PLAN -

AREA A

UPGRADE PRIMARY CARE

ANN ARBOR VAMC

506-20-103

1E

PROJECT DIRECTOR

APRIL 6, 2023 BC RM

100% BID

DOCUMENTS

E101A

FULLY SPRINKLERED

NORTH

SCALE: 1/4" = 1'-0"

ENLARGED LIGHTING PLAN - AREA A

KEYNOTES

1 UNSWITCHED EGRESS LIGHTING CIRCUITED TO THE PANEL AND

CIRCUIT SHOWN, FIELD VERIFY CIRCUIT AND PANEL AMPACITY

AVAILABILITY.

2 HOMERUN CIRCUITRY CONNECTED TO THE EXISTING

HOMERUN CIRCUITRY FROM THE DEMOLISHED LIGHT FIXTURES,

FIELD VERIFY THE ROUTE, CONNECTION REQUIREMENTS,

CIRCUIT NUMBER AND AVAILABLE PANEL AMPACITY.

3 PROVIDE TEMPORARY LIGHTING IN THE CORRIDOR DURING

CONSTRUCTION USING DEMOLISHED LIGHT FIXTURES AS

REQUIRED, FIELD VERIFY THE REQUIREMENTS.

4 HOMERUN CIRCUITRY ROUTED THROUGH THE EXISTING

BUILDING MANAGEMENT SYSTEM FOR CONTROL OF THE LIGHT

FIXTURES, FIELD VERIFY THE ROUTE AND CONNECTION

REQUIREMENTS.

5 EMERGENCY LIGHTING CIRCUITED TO THE PANEL AND CIRCUIT

SHOWN, FIELD VERIFY CIRCUIT AND PANEL AMPACITY

AVAILABILITY.

6 EXISTING LIGHT FIXTURE SHALL REMAIN.

7 NEW LOCATION FOR THE RELOCATED LIGHT FIXTURE, EXTEND

THE EXISTING CIRCUITRY TO THE NEW LOCATON SHOWN, FIELD

VERIFY THE REQUIREMENTS.

R L

DTS

DTS

R L

R L

R L

R L

R L

R L

R L

R L

DTS

R L

R L

OS

R L

DTS

RL4

R L

R L

R L

R L

R L

R L

R L

R L

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

R L

R L

R L

R L

R L

R L

R L

R L

R L

R L

R

L

R L

R L

OS

DTS

R L

PROCEDURE 3

D129

PATIENT TOILET

D130

EXAM/ CONSULT

D128

EXAM/ CONSULT.

D126

PATIENT TOILET

D131

CORRIDOR

D122

PROCEDURE 2

D112

PATIENT TOILET

D113

PATIENT TOILET

D110

EXAM/ CONSULT.

D116

EXAM/ CONSULT.

D114

PROCEDURE 1

D109

TEAM 1 WORK

ROOM

D148

EXAM/ CONSULT.

D107

EXAM/ CONSULT.

D115

EXAM/ CONSULT.

D117

EXAM/ CONSULT.

D119

MED ROOM

D121

EXAM/ CONSULT.

D123

EXAM/ CONSULT.

D125

SOILED UTILITY

D127

PROCEDURE 6

D156

EXAM/ CONSULT.

D154

EXAM/ CONSULT.

D152

HOUSEKEEPING

D157

CORRIDOR

D136

EXAM/ CONSULT.

D155

EXAM/ CONSULT.

D153

MED ROOM

D151

EXAM/ CONSULT.

D149

EXAM/ CONSULT.

D145

EXAM/ CONSULT.

D143

EXAM/ CONSULT.

D144

CR244E

CR244E

CR244E

CR244E

CR244E

CR244E

CR223E

CR223

CR223E

CR244

UW3

CR244

UW3

CR244

CR222E

CR222

CR222 CR222E CR222

CR223

CR222

CR222E

CR244E CR244E

CR244E CR244E

CR244E

CR244E

CR244

CR222E

UW3

CR244

CR244E

UW3

CR244E

CR244E

CR223E

CR223

CR244E

CR244E

CR244E

CR244E

CR223E

CR245 CR245

CR222

CR244E

CR222

CR244E CR244E

CR244E CR244E

CR244E

CR244E

CR244E

CR244E

CR244E

CR244E

CR244CR244

CR244 CR244

CR244CR244

CR244E

CR244E

CR244E

CR244E

UW3

CR244

CR244E

CR244E

CR244E

CR244E

CR244E

CR244E

CR244E

CR244E

CR244E

CR244E

CR244 CR244

CR244E

CR244E

CR244E

CR244E

CR244E CR244E

CR244ECR244E

CR244E CR223E

CR244CR244

CORRIDOR

D134

PATIENT TOILET

D146 EXAM/ CONSULT.

D145

CORRIDOR

D134

CORRIDOR

D135

EXAM/ CONSULT.

D117

CR244E

CR223E CR223 CR223E CR223 CR223E CR223 CR223E CR223 CR223E CR223

CR223E CR223E

CR223CR223

CR223ECR223E

CR223CR223

CR223E CR223E

CR223 CR223

CR223

CR223E CR223E

C41

C41

CR223 CR223

CR223ECR223E

CR223

CR223E

CR223

CR223E

CR244

CR223

CR223E

CR223

CR223E

CR223

CR223 CR223

CR223 CR223

CR223E CR223E

CR223 CR223

CR223E CR223E

CR222

CR223 CR223

CR223E CR223E

EXC1

EXC2

EXC1

EXC1

EXC1

CR223E CR223E

CR223E CR223E

EXC2

CR244E

CR244E

CR244E

CR244E

CR222

CR222

CR222E

CR222

CR222

CR222

CR222

CR222 CR222E

CR222 CR222

C25

C25C25

CORRIDOR

D134

TEAM 2 WORK

ROOM

D150

TELEHEALTH

D111D

STAFF UROLOGY

WORK ROOM

D111B

DTS

DTS

DTS

DTS

DTS

DTS

DTS

CR223 CR223E CR223

CR223 CR223

CR223 CR223E CR223

CR223 CR223

CR223 CR223E CR223

CR223 CR223

CR223 CR223E CR223

CR223 CR223

CR223 CR223E CR223

LS1-05- 9

LS1-05- 9

L1-01- 22

L1-01- 22

L1-01- 22

L1-01- 1

L1-01- 13

L1-01- 5

L1-01- 5

L1-01- 7

L1-01- 13

CL1-09- 9

CL1-09- 9

CL1-09- 9

L1-01- 1

CL1-09- 9

LS1-07- 14

LS1-07- 14

LS1-07- 14

LS1-07- 14

LS1-07- 14

LS1-07- 14

LS1-07- 14

LS1-07- 14

CL1-09- 9

LS1-07- 14

LS1-07- 14

LS1-07- 14

LS1-07- 14

LS1-07- 14

LS1-07- 14

LS1-07- 14

LS1-07- 14

LS1-07- 16

LS1-07- 16

L1-01- 12

TEMPORARY

WAITING ROOM

D164

MX448

MX448

MX448

MX448

MX448

MX448

MX448MX448

MX448

MX448

MX448

MX448

MX448

MX448

EXC1

EXC1

CR223

CR223

CR223

CR223

4L1-01- 13

L1-01- 223

LS1-07- 16

LS1-05- 9

L1-01- 12

LS1-05- 11

D

D

D

CR244E

CR244E

CR244E

CL1-09- 9

IUL

IUL

CL1-09- 9

B R A D E N

S .

C O X

6201070323

NO.

ENGINEER

S T

A

T E

O F M I C

H I

G A

N

R E

E N

I G

N

E L

ANOISSEFORP

D

E S

N E

C I

L

AREA - A

AREA - B

AREA - C

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

DWG. ___ OF 145

7GAE PROJECT NO.: 219123

Sprinkler:

600 E. Michigan Avenue, Suite B

Kalamazoo, MI 49007

P: 269.927.0144 www.7GenAE.com

2850 Eisenhower Ave, Suite 310

Alexandria, VA 22314

P: 202.617.8485 www.alliance.us.com

100% BID DOCUMENTS APRIL 6, 2023

ENLARGED LIGHTING PLAN -

AREA B

UPGRADE PRIMARY CARE

ANN ARBOR VAMC

506-20-103

1E

PROJECT DIRECTOR

APRIL 6, 2023 BC RM

100% BID

DOCUMENTS

E101B

FULLY SPRINKLERED

NORTH

SCALE: 1/4" = 1'-0"

ENLARGED LIGHTING PLAN - AREA B

KEYNOTES

1 HOMERUN CIRCUITRY CONNECTED TO THE EXISTING

HOMERUN CIRCUITRY FROM THE DEMOLISHED LIGHT FIXTURES,

FIELD VERIFY THE ROUTE, CONNECTION REQUIREMENTS,

CIRCUIT NUMBER AND AVAILABLE PANEL AMPACITY.

2 UNSWITCHED EGRESS LIGHTING CIRCUITED TO THE PANEL AND

CIRCUIT SHOWN, FIELD VERIFY CIRCUIT AND PANEL AMPACITY

AVAILABILITY.

3 HOMERUN CIRCUITRY ROUTED THROUGH THE EXISTING

BUILDING MANAGEMENT SYSTEM FOR CONTROL OF THE LIGHT

FIXTURES, FIELD VERIFY THE ROUTE AND CONNECTION

REQUIREMENTS.

4 PROVIDE TEMPORARY LIGHTING IN THE CORRIDOR DURING

CONSTRUCTION USING DEMOLISHED LIGHT FIXTURES AS

REQUIRED, FIELD VERIFY THE REQUIREMENTS.

5 EMERGENCY LIGHTING CIRCUITED TO THE PANEL AND CIRCUIT

SHOWN, FIELD VERIFY CIRCUIT AND PANEL AMPACITY

AVAILABILITY.

6 IN-USE LIGHT FIXTURE MOUNTED WITH THE CENTER AT 8'-0"

ABOVE THE FINISH FLOOR.

7 SWITCH WITH AN ENGRAVED FACEPLATE "CORRIDOR IN-USE

LIGHT".

R L

DTS

DTS

RL4 RL4

DTS

DTS

OS

OS

RL4

RL4

OS OS OS OS

OS

R L

PATIENT TOILET

D130

TOILET

D163

CORRIDOR

D134

CLEAN SUPPLY

D160

PASSAGE

C1-21

EXAM/ CONSULT

D128

SOILED UTILITY

D127

OVERFLOW

STAFF WORK

ROOM

D159

TOILET

D158

HOUSEKEEPING

D157

LS1-05

L1-01

CL1-09

R1-13

R1-14

CR1-15

CR244E

CR244E

CR223E

CR244

UW3

CR244CR244

CR244

UW3

CR244 CR244

CR244 CR244

CR244CR244

CR244 CR244

UW3

CR244

CR244

CR244

CR244

CR244CR244

CR244

CR244

CR223E

CR244CR244

CR244

CR244

CR244CR244

CR244

CR223E

CR223

CR244E CR244E

CR244ECR244E

CR244CR244

CORRIDOR

D134

CORRIDOR

D134

CR223

CR223E CR223 CR223E CR223 CR223E CR223 CR223E CR223 CR223E CR223

CR223E CR223E

CR223

EXC1

360360360360

EXC2

EXC1

EXC1

EXC1 CR223E CR223E

EXC2

C25

C25C25

CORRIDOR

D134

BREAKROOM/

LOUNGE

D132

DTS

DTS

DTS

DTS

CR223 CR223E CR223

LS1-05- 9

LS1-05- 9

LS1-05- 9

L1-01- 1

L1-01- 3

L1-01- 3

L1-01- 3 L1-01- 3

L1-01- 3

L1-01- 12

L1-01- 13

L1-01- 5

L1-01- 5

L1-01- 7

L1-01- 1

CL1-09- 9

LS1-07- 16

LS1-07- 16

L1-01- 12

MX448MX448

EXC1

4L1-01- 13

LS1-07- 16

EXC1

PRIVATE WORK

ROOM

D162

B R A D E N

S .

C O X

6201070323

NO.

ENGINEER

S T

A

T E

O F M I C

H I

G A

N

R E

E N

I G

N

E L

ANOISSEFORP

D

E S

N E

C I

L

AREA - A

AREA - B

AREA - C

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

DWG. ___ OF 145

7GAE PROJECT NO.: 219123

Sprinkler:

600 E. Michigan Avenue, Suite B

Kalamazoo, MI 49007

P: 269.927.0144 www.7GenAE.com

2850 Eisenhower Ave, Suite 310

Alexandria, VA 22314

P: 202.617.8485 www.alliance.us.com

100% BID DOCUMENTS APRIL 6, 2023

ENLARGED LIGHTING PLAN -

AREA C

UPGRADE PRIMARY CARE

ANN ARBOR VAMC

506-20-103

1E

PROJECT DIRECTOR

APRIL 6, 2023 BC RM

100% BID

DOCUMENTS

E101C

FULLY SPRINKLERED

NORTH

SCALE: 1/4" = 1'-0"

ENLARGED LIGHTING PLAN - AREA C

KEYNOTES

1 UNSWITCHED EGRESS LIGHTING CIRCUITED TO THE PANEL AND

CIRCUIT SHOWN, FIELD VERIFY CIRCUIT AND PANEL AMPACITY

AVAILABILITY.

2 HOMERUN CIRCUITRY ROUTED THROUGH THE EXISTING

BUILDING MANAGEMENT SYSTEM FOR CONTROL OF THE LIGHT

FIXTURES, FIELD VERIFY THE ROUTE AND CONNECTION

REQUIREMENTS.

3 HOMERUN CIRCUITRY CONNECTED TO THE EXISTING

HOMERUN CIRCUITRY FROM THE DEMOLISHED LIGHT FIXTURES,

FIELD VERIFY THE ROUTE, CONNECTION REQUIREMENTS,

CIRCUIT NUMBER AND AVAILABLE PANEL AMPACITY.

4 PROVIDE TEMPORARY LIGHTING IN THE CORRIDOR DURING

CONSTRUCTION USING DEMOLISHED LIGHT FIXTURES AS

REQUIRED, FIELD VERIFY THE REQUIREMENTS.

5 EMERGENCY LIGHTING CIRCUITED TO THE PANEL AND CIRCUIT

SHOWN, FIELD VERIFY CIRCUIT AND PANEL AMPACITY

AVAILABILITY.

42"

EM

42"

EM

60"

60" 60"

60"

EM

EM

42"

EM

TP TP

TP

TP

42"

EM

GFI

TP

TP

GFI

TP

TP

42"

EM

42"

EM

42"

TP

TP

42"

EM

TP

TP

TP

TP

TP TP

TP

TP

TP

TP

GFI

34"

TP

GFI

34"

TP

TP

GFI

TP

GFI

TP

GFI

TP

GFI

TP

GFI

TP

GFI

TP

GFI

EM

TP

GFI

34"

TP

GFI

34"

TP

GFI

34"

TP

GFI

34"

TP

GFI

34"

TP

GFI

TP

GFI

TP

GFI

TP

GFI

TP

GFI

TP

TP

42"

TP

EM

EM

TP

TP

TPG

FI

TPTP

TP

TP

60"

TP

TP

GFI

42"

EM

TP

GFI

34"

TP

TP

TP

TP

TP

TP

TP

GFI

34"

TP

TP

GFI

TP

GFI

TP

GFI

TP

GFI

TP

GFI

TP

TP

TP

GFI

42"

TP

TP

TP

GFI

TP

TP

GFI

42"

TP

GFI

34"

TP

GFI

TP

GFI

34"

TP

TP

GFI

42"

TP

TP

TP

TP

TP

TP

TPG

FI

TP

TPG

FI

TP G

FI

TP G

FI

42"

EM

42"

EM

EM

EM

J J

TP

J

60"

60"

60"

J J J J

J

48"

J

J4 "J 4

TP

CLNG

J

CLNG

J

C L N

G

J

CLNG

J

C L N

G

J

J

J

48"

J

48"

J

48"

JJ J

J

J

48"

J4

J

J4

J

J

48"

J

J 4

J

J

J

48"

CLNG

J

J

CLNG

J

J

CLNG

J

J

CLNG

J

CLNG

J

CLNG

J

CLNG

J

CLNG

J

CLNG

J

CLNG

J

CLNG

J

J J

J

J

J

J

J

J

J

J

J

J

48"

GFI

TP

TPG

FI

"TP G

FI

TP

GFI

42"

J J

48"

J

48"

JJ

48"

J

48"

J

48"

J

48"

J

J

J

J

J

J

J

48"

J

J

48"

60"

TP

GFI

34"

TP

GFI

34"

TP

GFI

34"

TP

GFI

34"

TP

GFI

34"

TP

GFI

34"

TP

GFI

34"

TP

GFI

34"

TP

GFI

34"

J

J

48"

A

C

A C

A

C

A C

J

J

48"

J 4

J 4

J

J

J

J

CLNG

J

CLNG

J

CLNG

J

CLNG

J

CLNG

J

CLNG

J

CLNG

J

CLNG

J

CLNG

J

J

J

PROCEDURE 3

D129

PATIENT TOILET

D130

TOILET

D163

CORRIDOR

D134

CLEAN SUPPLY

D160 PASSAGE

C1-21

EXAM/ CONSULT

D128

EXAM/ CONSULT.

D126

PATIENT TOILET

D131

CORRIDOR

D122

PATIENT TOILET

D113

PATIENT TOILET

D110

EXAM/ CONSULT.

D114

PROCEDURE 1

D109

EXAM/ CONSULT.

D104

CORRIDOR

D135A

INTAKE 1

D102

INTAKE 2

D103

TEAM 1 WORK

ROOM

D148

HEIGHT &

WEIGHT

D105

PRIVATE VIRTUAL

D147

EXAM/ CONSULT.

D106

EXAM/ CONSULT.

D107

EXAM/ CONSULT.

D115

EXAM/ CONSULT.

D117

EXAM/ CONSULT.

D119

MED ROOM

D121

EXAM/ CONSULT.

D123

EXAM/ CONSULT.

D125

SOILED UTILITY

D127

PROCEDURE 6

D156

EXAM/ CONSULT.

D154

EXAM/ CONSULT.

D152

OVERFLOW

STAFF WORK

ROOM

D159

TOILET

D158

HOUSEKEEPING

D157

CORRIDOR

D136

EXAM/ CONSULT.

D155

EXAM/ CONSULT.

D153

MED ROOM

D151

EXAM/ CONSULT.

D149

EXAM/ CONSULT.

D143

EXAM/ CONSULT.

D141

EXAM/ CONSULT.

D144

EXAM/ CONSULT.

D142

EXAM/ CONSULT.

D140

EXAM/ CONSULT.

D138

HEIGHT &

WEIGHT

D137

EXAM/ CONSULT.

D139

TEAM 2 WORK

ROOM

D150

PROCEDURE 2

D112

EXAM/ CONSULT.

D116

PATIENT TOILET

D146

ELEC

D100A

CORRIDOR

D135

TEAM 2 WORK

ROOM

D150

CORRIDOR

D135

TEAM 1 WORK

ROOM

D148 EXAM/ CONSULT.

D145

CORRIDOR

D134

CORRIDOR

D134 E201B

E201CE201C

E201A

E201BE201B

E201B

E201CE201C

E201A

E201BE201B

STAFF UROLOGY

WORK ROOM

D111B

BREAKROOM/

LOUNGE

D132

TELEHEALTH

D111D

PATIENT TOILET

D108

WAITING AREA

D100

PT

D111A

B R A D E N

S .

C O X

6201070323

NO.

ENGINEER

S T

A

T E

O F M I C

H I

G A

N

R E

E N

I G

N

E L

ANOISSEFORP

D

E S

N E

C I

L

AREA - A

AREA - B

AREA - C

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

DWG. ___ OF 145

7GAE PROJECT NO.: 219123

Sprinkler:

600 E. Michigan Avenue, Suite B

Kalamazoo, MI 49007

P: 269.927.0144 www.7GenAE.com

2850 Eisenhower Ave, Suite 310

Alexandria, VA 22314

P: 202.617.8485 www.alliance.us.com

100% BID DOCUMENTS APRIL 6, 2023

FIRST FLOOR POWER PLAN UPGRADE PRIMARY CARE

ANN ARBOR VAMC

506-20-103

1E

PROJECT DIRECTOR

APRIL 6, 2023 BC RM

100% BID

DOCUMENTS

E201

FULLY SPRINKLERED

GENERAL POWER NOTES

A WHERE CONNECTED TO A 20A. BRANCH CIRCUIT SUPPLYING AN

INDIVIDUAL RECEPTACLE (SIMPLEX OR DUPLEX), THE

RECEPTACLE SHALL BE RATED AT 20A.

B REFER TO SECTION 26 0519 FOR MINIMUM CONDUCTOR SIZE

ADJUSTMENTS FOR VOLTAGE DROP.

C CIRCUIT WIRING IS NOT SHOWN EXCEPT FOR SWITCHING INTENT

OF FIXTURES AND CONTROL OF DEVICES.

D PROVIDE PROPER NUMBER OF CONDUCTORS TO ACHIEVE

CIRCUITING AND SWITCHING SHOWN.

E CIRCUIT NUMBERS AT DEVICES CORRESPOND TO PANELBOARD

BREAKERS (SEE PANELBOARD SCHEDULE). BRANCH CIRCUITS

SHALL BE SIZED ACCORDING TO THE CIRCUIT BREAKER RATING,

UNLESS INDICATED OTHERWISE ON THE ELECTRICAL EQUIPMENT

SCHEDULE.

F SINGLE PHASE BRANCH CIRCUITS SHALL NOT SHARE NEUTRALS.

G THE CONTRACTOR SHALL PROVIDE THE FIRE ALARM SYSTEM AND

NURSE CALL SYSTEM'S DEVICES AND DATA CONNECTION

CONDUITS AND BOXES, PER THE "INFORMATION BOX DETAIL".

REFER TO THE SPECIAL SYSTEMS PLANS FOR BOX LOCATIONS.

FIELD VERIFY THE BOX LOCATIONS AND CONDUIT ROUTES.

H THE CONTRACTOR SHALL PROVIDE THE REQUIRED POWER FOR

ALL MECHANICAL OR PLUMBING EQUIPMENT SPECIFIED IN THE

CONTRACT DOCUMENTS, EVEN IF NOT SHOWN ON THE POWER

PLANS. FIELD VERIFY THE POWER REQUIREMENTS OF ALL

MECHANICAL AND PLUMBING EQUIPMENT, WITH THE

EQUIPMENT SUPPLIERS, PRIOR TO PREPARING SUBMITTALS OR

ORDERING ANY SWITCHGEAR OR EQUIPMENT. SUPPLIED

PLUMBING AND/OR MECHANICAL EQUIPMENT MAY VARY.

I THE CONTRACTOR SHALL FIELD VERIFY THE ROUGH-IN

DIMENSIONS OF ALL FLOOR BOXES, DATA OUTLETS, TV OUTLETS

AND TV RECEPTACLES PRIOR TO ANY INSTALLATION. ANY

CHANGE OF LOCATION OF A BOX THAT WAS NOT VERIFIED WITH

THE OWNER PRIOR TO INSTALLATION SHALL BE RELOCATED AT

THE CONTRACTOR'S EXPENSE TO THE SATISFACTION OF THE

OWNER.

J FOR EACH THERMOSTAT, TEMPERATURE SENSOR OR WALL

MOUNTED CONTROL DEVICE PROVIDE A JUNCTION BOX, WITH

A SINGLE GANG MUD RING, AT 48” ABOVE THE FINISH FLOOR

WITH A ¾” CONDUIT (WITH A PULL STRING) TO ABOVE THE

CEILING FOR THE MECHANICAL CONTROLS. REFER TO THE

MECHANICAL PLANS FOR INFORMATION.

K RE-USE EXISTING ELECTRICAL DEVICE HOME RUN CIRCUITRY

FROM THE DEMOLISHED DEVICES. THE CIRCUIT NUMBER SHOWN

IS AN ATTEMPT TO DETERMINE EXISTING CIRCUIT. FIELD VERIFY

THE NEAREST RECEPTACLE CIRCUIT NUMBER, LOCATION,

AVAILABLE AMPACITY AND CONNECTION LOCATIONS. EXTEND

THE CIRCUITRY AS REQUIRED.

L REFER TO THE INTERSTITIAL MECHANICAL PLANS FOR THE VAV

BOX LOCATIONS FOR POWER CONNECTIONS. VAV BOXES ARE

SHOWN ON THE FIRST FLOOR POWER PLAN FOR CLARITY ONLY.

M PROVIDE ALL POWER CONNECTIONS FOR THE PNUEMATIC TUBE

INFORMATION TRANSFER SYSTEM. PROVIDE ALL COMPONENTS

REQUIRED FOR A COMPLETE OPERATIONAL SYSTEM. REFER TO

THE MANUFACTURER'S INSTALLATION REQUIREMENTS.

NORTH

SCALE: 1/8" = 1'-0"

FIRST FLOOR POWER PLAN

42"

EM

60" 60"

42"

EM

TP TP

TP

GFI

TP

42"

EM

42"

TP

TP

TP

TP

TP

TPTP

TP

GFI

TP

GFI

TP

GFI

TP

GFI

34"

TP

GFI

34"

TP

GFI

EM

TP

TPG

FI

TPTP

TP

TP

60"

TP

TP

GFI

42"

EM

TP

GFI

34"

TP

TP

GFI

34"

TP

TP

GFI

TP

GFI

TP

TP

TP

GFI

42"

TP

GFI

TP

TP

GFI

42"

TP

GFI

34"

TP

GFI

TP

GFI

34"

TP

TP

TP

J

60"

60"

J J J J

J

48"

J

J4 "J

C L N

G

J

C L N

G

J

J

J

48"

J

CLNG

J

CLNG

J

J

J

J

48"

J

48"

J

J

J

J

48"

J

J

48"

TP

GFI

34"

J 4

J

J

J

J

J

CLNG

J

CLNG

J

CLNG

J

CLNG

J

PROCEDURE 1

D109

EXAM/ CONSULT.

D104

CORRIDOR

D135A

INTAKE 1

D102INTAKE 2

D103

TEAM 1 WORK

ROOM

D148

HEIGHT &

WEIGHT

D105

PRIVATE VIRTUAL

D147

EXAM/ CONSULT.

D106

EXAM/ CONSULT.

D107

EXAM/ CONSULT.

D115

CR1-23

R1-22

CL1-11

LS1-07

L1-03

A C

EM TP

A C

EM G

FI

A C

G

FI

A C

G

FI

A C

G

FI TP

AC

GFI

TP

AC

GFI

TP

G

FI

G

FI

EXAM/ CONSULT.

D143

EXAM/ CONSULT.

D141

EXAM/ CONSULT.

D142

EXAM/ CONSULT.

D140

EXAM/ CONSULT.

D138

HEIGHT &

WEIGHT

D137

EXAM/ CONSULT.

D139

TEAM 2 WORK

ROOM

D150

ELEC

D100A

C…

This is the start of the file's text. The full file is on GovTribe.