36C25018B0815-0002010.pdf

PDF 444 KB Posted

Attached to
Remodel Pharmacy IV Prep Room - FCA Project 757-19-101
Solicitation number
36C25018B0815
Issued by

About this file

36C25018B0815 0002 VA Columbus, MOBILE COMPOUNDING CUT SHEET .pdf

View the file

Other files

File Type Posted
36C25019C0025-000.docx DOCX document
36C25018B0815-0003000.docx DOCX document
36C25018B0815-0002007.pdf PDF
36C25018B0815-0002004.pdf PDF
36C25018B0815-0002002.pdf PDF
36C25018B0815-0002006.pdf PDF
36C25018B0815-0002005.pdf PDF
36C25018B0815-0002003.pdf PDF
36C25018B0815-0002000.docx DOCX document
36C25018B0815-0002008.pdf PDF
36C25018B0815-0002001.pdf PDF
36C25018B0815-0002009.pdf PDF
36C25018B0815-0001000.docx DOCX document
36C25018B0815-003.pdf PDF
36C25018B0815-001.docx DOCX document
36C25018B0815-004.txt TXT text file
36C25018B0815-002.pdf PDF
36C25018B0815-000.docx DOCX document
Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CONFIDENTIAL

August 22, 2018 Page 1 of 8

Prepared for:

VAACC Columbus, OH

Pharmacy IV Prep Room

TEMPORARY MOBILE COMPOUNDING CENTER QUOTATION

3730 Hampton Avenue 800-418-9289

St. Louis, MO 63109 AsepticEnclosures.com fax 800-829-5742

© 2018 Aseptic Enclosures. ALL RIGHTS RESERVED. Confidential – Property of Aseptic Enclosures Any use of materials including reproduction, modification, distribution or republication, without the prior written consent of Aseptic Enclosures, is strictly prohibited.

Confidentiality: This document is not to be distributed to any person outside your organization without written approval

Scope of work: To supply a USP<800> compliant, self-contained mobile compounding center. This is to be a 3 room layout. A vestibule, Hepa filtered, work area, Positive Pressure Ante area and a Negative pressure Buffer room with 2 48x32NP CACIs. This will include provision and installation of all represented interior components including external exhausting, exhaust filtration, exhaust alarm, air handling, HVAC control, HEPA filtration, ceiling system, lighting, wall panels, doors, auto open actuators, shelving units, engineering controls (Isolators), exhausting for user supplied refrigerator, switches, gauges, eyewash, sink, 2 mobile office workstations with data and communications connections. Also included is an on-site project review meeting, installation supervision and in service training. Security Deadbolt and Keypad Access. 2 station Cleanroom Intercom system.

August 22, 2018 Page 2 of 8

Any use of materials including reproduction, modification, distribution or republication, without the prior written

Site requirements and Installation Recommendations to Buyer:

Electrical supply required: 120/240/208V single phase 200 amps. Connection By

Others.

Dimensions: 42ft long x 8ft wide x 9’6” high

Total weight: Approximately 15,000lbs

Occupancy Capacity: International Building Code (IBC) 21. We recommend 6 or less.

Building Type: Can vary based on local codes, typically ancillary.

Placement: This equipment can be installed free standing without any additional ground prep, however settling can occur and operationally, settling may create an issue for utility connections or internal working environment. It is best for the Mobile Compounding Center to be placed upon a level foundation for, ease of presenting utilities to the unit, and reduced moisture from ground to floor contact. Unit’s payload capacity is 67,000 pounds that is designed to be fully supported by the corners.

A concrete slab or pad footings are recommended. Foundation anchors can be provided as an option. Civil Engineering for local site placement is available.

Access for placement: Typical shipment is from a roll-off tilt-bed tractor trailer. 120ft straight line access is required. Forklift rigging is available.

August 22, 2018 Page 3 of 8

Any use of materials including reproduction, modification, distribution or republication, without the prior written consent of Aseptic Enclosures, is strictly prohibited.

Freight and rigging is not included. Estimated charge for pickup 350.00 and placement 350.00 (assuming roll off) + approximately 3.00 per mile from St.

Louis. The unit can optionally be supplied on a chassis.

Plumbing connection: Plumbing connections are readily customized to your requirements. Final connection BY OTHERS. Standard is ½ copper cold water only. Brought into the side 18in above base of container. Pipe is thermostat controlled heat wrapped and insulated connected to an external mounted GFCI outlet. Heat wrapping can be supplied in additional lengths for owner’s connection. Optional, on demand, hot water system also available. A through floor pipe connection is also available.

Venting: Exhausting is included. Exhaust fan should be specified to be located away from building intakes.

Electrical Requirements: Connection by Others. Required service.

240/208/120 three phase, 200amp.

August 22, 2018 Page 4 of 8

Any use of materials including reproduction, modification, distribution or republication, without the prior written

August 22, 2018 Page 5 of 8

Any use of materials including reproduction, modification, distribution or republication, without the prior written

Electrical Connection: 208 Y /120. We run this into our 200amp panel.

Connection Location and type to be specified based on site.

August 22, 2018 Page 6 of 8

Any use of materials including reproduction, modification, distribution or republication, without the prior written

August 22, 2018 Page 7 of 8

Any use of materials including reproduction, modification, distribution or republication, without the prior written consent of Aseptic Enclosures, is strictly prohibited.

Plumbing connection type and location is flexible based on site requirements.

A hot water heating system is supplied. This supply is to a 3gpm handwashing sink. Drain location is also flexible.

August 22, 2018 Page 8 of 8

Any use of materials including reproduction, modification, distribution or republication, without the prior written

File details come from the government source that posted it.